Title: Transjugular Liver Biopsy: A Review of 77 Biopsies Using a Spring-Propelled Cutting Needle (Biopsy Gun)

Journal Article · · Cardiovascular and Interventional Radiology
DOI:https://doi.org/10.1007/S002709900096· OSTI ID:21080482
;  [1];  [2]; ;  [1]; ;  [2];  [1]
  1. Departments of Radiology and Gastroenterology, Hospital Ntra. Sra. del Pino, Angel Guimera 91, 35004 Las Palmaz, Gran Canaria (Spain)
  2. Department of Radiology, Rm. 212, LSU Medical Center, 1542 Tulane Avenue, New Orleans, LA 70112 (United States)

Seventy-seven transjugular liver biopsies were performed with a coaxial, spring-loaded, 18-gauge cutting needle, the Biopty gun (Bard Biopsy System, Covington, GA, USA) on consecutive patients between July 1993 and February 1995. Fifty men and 27 women were included in the study; the mean age was 45 years (range 15-69 years). The average number of punctures per patient was 5.2, with a range of 2-9, yielding an average of 4.8 samples per patient (range 1-7). The length of the samples varied from 10 to 22 mm with a constant diameter of 1 mm. The mean time required to complete the procedure was 48 min (43-52 min). Histological diagnoses were obtained in 74 of 77 patients (96%), with non-diagnostic specimens attributed to excessive fragmentation (3 cases). Complications occurred in 10 patients (puncture site hematoma, carotid artery puncture, abdominal pain, vasovagal reaction, hepatic capsule perforation, and hemobilia). The latter two complications were self-limited. In our experience this transjugular hepatic biopsy method is promising for performing biopsies in patients with chronic liver disease, due to its high success rate and low morbidity rate.

OSTI ID:
21080482
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 19, Issue 6; Other Information: DOI: 10.1007/s002709900096; Copyright (c) 1996 Springer-Verlag New York Inc; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Transjugular Core Liver Biopsy with a 19-Gauge Spring-Loaded Cutting Needle
Journal Article · Thu Jan 15 00:00:00 EST 1998 · Cardiovascular and Interventional Radiology · OSTI ID:21080482

Transjugular Renal Biopsy: Our Experience and Technical Considerations
Journal Article · Mon Sep 15 00:00:00 EDT 2008 · Cardiovascular and Interventional Radiology · OSTI ID:21080482

A Comparison of Four- Versus Three-Pass Transjugular Biopsy Using a 19-G Tru-Cut Needle and a Randomized Study Using a Cassette to Prevent Biopsy Fragmentation
Journal Article · Fri May 15 00:00:00 EDT 2009 · Cardiovascular and Interventional Radiology · OSTI ID:21080482