Title: Digital radiographic systems detect boiler tube cracks

Journal Article · · Power (New York)
OSTI ID:21073728
 [1]
  1. EPRI, Charlotte, NC (United States)

Boiler water wall leaks have been a major cause of steam plant forced outages. But conventional nondestructive evaluation techniques have a poor track record of detecting corrosion fatigue cracking on the inside surface of the cold side of waterwall tubing. EPRI is performing field trials of a prototype direct-digital radiographic system that promises to be a game changer. 8 figs.

OSTI ID:
21073728
Journal Information:
Power (New York), Vol. 152, Issue 6; ISSN 0032-5929
Country of Publication:
United States
Language:
English