skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Radial Power Profile of MOX and LEU Fuel Pellet Versus Burnup

Conference ·
OSTI ID:21064630
;  [1]
  1. INEEL - Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID 83415 (United States)

One of challenge to burn the WG-Pu in Mixed Oxide (MOX) fuel in light water reactors (LWR) is to demonstrate that the differences between WG-MOX, RG-MOX, and LWR LEU fuel are minimal, and therefore, the commercial MOX and LEU fuel experience base is applicable. The MCWO-calculated Radial Power Profile of LEU, Weapons Grade-MOX and Reactor Grade-MOX fuel pellets at various burnups are similar toward the end of life (50 GWd/t). Therefore, the LEU fuel performance evaluation code - FRAPCON-3 with modifications, such as, the detailed fission power profiles versus burnup, can be used in the MOX fuel pellet performance analysis. MCWO also calculated the {sup 240}Pu/Pu ratio in WG-MOX versus burnup, which reaches an average of 31.25% at discharged burnup of 50 GWd/t. It meets the spent fuel standard for WG-Pu disposition in LWR. (authors)

Research Organization:
The ASME Foundation, Inc., Three Park Avenue, New York, NY 10016-5990 (United States)
OSTI ID:
21064630
Resource Relation:
Conference: ICONE-10: 10. international conference on nuclear engineering, Arlington - Virginia (United States), 14-18 Apr 2002; Other Information: Country of input: France
Country of Publication:
United States
Language:
English