Title: Evaluation of the Risk of Damages in Mixing Zones: EDF R and D Programme

Conference ·
OSTI ID:21062323

Following the incident (through-wall crack and crazing zones) of May 1998 on the principal mixing zone of the residual heat removal system at CIVAUX nuclear plant, EDF has initiated a R and D programme to understand the incident and assess the risks of damage on other nuclear plant mixing zones. The programme includes different sectors of development: assessment of temperature fluctuations in mixing zones, study of high-cycle thermal fatigue behaviour of austenitic steel and development of mechanical methodologies for damage assessment and propagation of crazing zones (thermal striping). A series of tests is being performed in support of the programme. The paper develops the description of each sector of the programme: tests performed, on-site measurements and numerical interpretations. The first results are presented. (authors)

Research Organization:
The ASME Foundation, Inc., Three Park Avenue, New York, NY 10016-5990 (United States)
OSTI ID:
21062323
Resource Relation:
Conference: ICONE 10: 10. international conference on nuclear engineering, Arlington - Virginia (United States), 14-18 Apr 2002; Other Information: Country of input: France
Country of Publication:
United States
Language:
English