Abstract

We report that the magnified imaging using the portable synchrotron named MIRRORCLE has unique advantages for non-destructive inspection (NDI) of some products. This machine is a high energy x-ray source which can have a micron-sized point source, which is different from the conventional synchrotron, linear accelerator and the x-ray tube. The images produced with micron-sized point source and wide spectrum can display in detail the industrial products containing several materials in detail. The obtained x-ray images characterization is expected to provide a new tool for NDI of industrial products.

Authors:
; ;  [1];  [1]; ;  [2]
  1. Faculty of science and Engineering, Ritsumeikan University, Kusatsu, Shiga, 525-8577 (Japan)
  2. Photon Production Laboratory Ltd, Omihachiman, Shiga, 523-0898 (Japan)
Publication Date:
OSTI Identifier:
21056934
Resource Type:
Journal Article
Journal Name:
AIP Conference Proceedings
Additional Journal Information:
Journal Volume: 902; Journal Issue: 1; Conference: 2. international symposium on portable synchrotron light sources and advanced applications, Shiga (Japan), 15-17 Jan 2007; Other Information: DOI: 10.1063/1.2723634; (c) 2007 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); Journal ID: ISSN 0094-243X
Country of Publication:
United States
Language:
English
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; IMAGES; POINT SOURCES; PORTABLE SOURCES; SYNCHROTRON RADIATION; SYNCHROTRONS; X RADIATION; X-RAY RADIOGRAPHY

Citation Formats

Hirai, T, Sasaki, M, Nihira, T, Yamada, H, Synchrotron Light Life Science Center, Ritsumeikan University, Kusatsu, Shiga, 525-8577, Morita, M, and Hasegawa, D. Magnified NDI Imaging Using MIRRORCLE-Type Table-Top Synchrotron. United States: N. p., 2007. Web. doi:10.1063/1.2723634.
Hirai, T, Sasaki, M, Nihira, T, Yamada, H, Synchrotron Light Life Science Center, Ritsumeikan University, Kusatsu, Shiga, 525-8577, Morita, M, & Hasegawa, D. Magnified NDI Imaging Using MIRRORCLE-Type Table-Top Synchrotron. United States. https://doi.org/10.1063/1.2723634
Hirai, T, Sasaki, M, Nihira, T, Yamada, H, Synchrotron Light Life Science Center, Ritsumeikan University, Kusatsu, Shiga, 525-8577, Morita, M, and Hasegawa, D. 2007. "Magnified NDI Imaging Using MIRRORCLE-Type Table-Top Synchrotron". United States. https://doi.org/10.1063/1.2723634.
@article{osti_21056934,
title = {Magnified NDI Imaging Using MIRRORCLE-Type Table-Top Synchrotron},
author = {Hirai, T and Sasaki, M and Nihira, T and Yamada, H and Synchrotron Light Life Science Center, Ritsumeikan University, Kusatsu, Shiga, 525-8577 and Morita, M and Hasegawa, D},
abstractNote = {We report that the magnified imaging using the portable synchrotron named MIRRORCLE has unique advantages for non-destructive inspection (NDI) of some products. This machine is a high energy x-ray source which can have a micron-sized point source, which is different from the conventional synchrotron, linear accelerator and the x-ray tube. The images produced with micron-sized point source and wide spectrum can display in detail the industrial products containing several materials in detail. The obtained x-ray images characterization is expected to provide a new tool for NDI of industrial products.},
doi = {10.1063/1.2723634},
url = {https://www.osti.gov/biblio/21056934}, journal = {AIP Conference Proceedings},
issn = {0094-243X},
number = 1,
volume = 902,
place = {United States},
year = {Fri Mar 30 00:00:00 EDT 2007},
month = {Fri Mar 30 00:00:00 EDT 2007}
}