skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Active breathing control (ABC): Determination and reduction of breathing-induced organ motion in the chest

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1];  [1];  [1];  [1];  [1];  [2];  [3];  [1];  [1];  [1];  [4];  [1]
  1. Department of Radiotherapy, RWTH Aachen University, Aachen (Germany)
  2. Institute of Medical Statistics, RWTH Aachen University, Aachen (Germany)
  3. Department of Internal Medicine, RWTH Aachen University, Aachen (Germany)
  4. Department of Diagnostic Radiology, RWTH Aachen University, Aachen (Germany)

Purpose: Extensive radiotherapy volumes for tumors of the chest are partly caused by interfractional organ motion. We evaluated the feasibility of respiratory observation tools using the active breathing control (ABC) system and the effect on breathing cycle regularity and reproducibility. Methods and Materials: Thirty-six patients with unresectable tumors of the chest were selected for evaluation of the ABC system. Computed tomography scans were performed at various respiratory phases starting at the same couch position without patient movement. Threshold levels were set at minimum and maximum volume during normal breathing cycles and at a volume defined as shallow breathing, reflecting the subjective maximal tolerable reduction of breath volume. To evaluate the extent of organ movement, 13 landmarks were considering using commercial software for image coregistration. In 4 patients, second examinations were performed during therapy. Results: Investigating the differences in a normal breathing cycle versus shallow breathing, a statistically significant reduction of respiratory motion in the upper, middle, and lower regions of the chest could be detected, representing potential movement reduction achieved through reduced breath volume. Evaluating interfraction reproducibility, the mean displacement ranged between 0.24 mm (chest wall/tracheal bifurcation) to 3.5 mm (diaphragm) for expiration and shallow breathing and 0.24 mm (chest wall) to 5.25 mm (diaphragm) for normal inspiration. Conclusions: By modifying regularity of the respiratory cycle through reduction of breath volume, a significant and reproducible reduction of chest and diaphragm motion is possible, enabling reduction of treatment planning margins.

OSTI ID:
20944724
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 67, Issue 3; Other Information: DOI: 10.1016/j.ijrobp.2006.09.052; PII: S0360-3016(06)03235-4; Copyright (c) 2007 Elsevier Science B.V., Amsterdam, Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer
Journal Article · Tue Feb 01 00:00:00 EST 2005 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20944724

SU-F-BRB-03: Quantifying Patient Motion During Deep-Inspiration Breath-Hold Using the ABC System with Simultaneous Surface Photogrammetry
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:20944724

Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy
Journal Article · Wed Mar 01 00:00:00 EST 2006 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20944724