Title: Time-Varying Characteristics Analysis and Fuzzy Controller Systematic Design Method for Pressurized Water Reactor Power Control

Journal Article · · Nuclear Science and Engineering
OSTI ID:20808402

In this paper a systematic design method of fuzzy control systems is applied to the pressurized water reactor's (PWR) power control. The paper includes three parts. In the first part, a simplified time-varying linear model of the PWR power system is constructed, and its inner structure and time-varying characteristics are analyzed. That provides a solid basis for study and design of the nuclear reactor power control system. In the second part, a systematic design method of fuzzy control systems is introduced and applied to control the nuclear reactor power process. The design procedures and parameters are given in detail. This systematic design method has some notable advantages. The control of a global fuzzy model can be decomposed into controlling a set of linear submodels. Each submodel controller can be independently designed by using a linear quadratic regulator approach. This systematic design method gives a sufficient and necessary condition to guarantee the stability of fuzzy control systems; thus, better control performance can be obtained due to the accurate control gains. In the third part, the control performance of the nuclear reactor fuzzy control system is examined by simulation experiments, including nuclear reactor power shutdown, start-up, and adjustment operations. The satisfactory experiment results have shown that the systematic design method for fuzzy control systems is effective and feasible.

OSTI ID:
20808402
Journal Information:
Nuclear Science and Engineering, Vol. 148, Issue 3; Other Information: Copyright (c) 2006 American Nuclear Society (ANS), United States, All rights reserved. http://epubs.ans.org/; Country of input: International Atomic Energy Agency (IAEA); ISSN 0029-5639
Country of Publication:
United States
Language:
English

Similar Records

Fuzzy power control algorithm for a pressurized water reactor
Journal Article · Sun May 01 00:00:00 EDT 1994 · Nuclear Technology; (United States) · OSTI ID:20808402

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems
Journal Article · Thu Jan 21 00:00:00 EST 2021 · IEEE Transactions on Fuzzy Systems · OSTI ID:20808402

Design of stability-guaranteed fuzzy logic controller for nuclear steam generators
Journal Article · Mon Apr 01 00:00:00 EST 1996 · IEEE Transactions on Nuclear Science · OSTI ID:20808402