skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Effects of point configuration on the accuracy in 3D reconstruction from biplane images

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.2008467· OSTI ID:20726236
; ; ; ;  [1]
  1. Department of Mathematics and Statistics, UNC Charlotte, 9201 University City Boulevard, Charlotte, North Carolina 28223-0001 (United States)

Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate the effect of the shape of the configuration of the points in 3D (the 'cloud' of points) on reconstruction errors for one of these techniques developed in our laboratory. Five types of configurations (a ball, an elongated ellipsoid (cigar), flattened ball (pancake), flattened cigar, and a flattened ball with a single distant point) are used in the evaluations. For each shape, 100 random configurations were generated, with point coordinates chosen from Gaussian distributions having a covariance matrix corresponding to the desired shape. The 3D data were projected into the image planes using a known imaging geometry. Gaussian distributed errors were introduced in the x and y coordinates of these projected points. Gaussian distributed errors were also introduced into the gantry information used to calculate the initial imaging geometry. The imaging geometries and 3D positions were iteratively refined using the enhanced-Metz-Fencil technique. The image data were also used to evaluate the feasible R-t solution volume. The 3D errors between the calculated and true positions were determined. The effects of the shape of the configuration, the number of points, the initial geometry error, and the input image error were evaluated. The results for the number of points, initial geometry error, and image error are in agreement with previously reported results, i.e., increasing the number of points and reducing initial geometry and/or image error, improves the accuracy of the reconstructed data. The shape of the 3D configuration of points also affects the error of reconstructed 3D configuration; specifically, errors decrease as the 'volume' of the 3D configuration increases, as would be intuitively expected, and shapes with larger spread, such as spherical shapes, yield more accurate reconstructions. These results are in agreement with an analysis of the solution volume of feasible geometries and could be used to guide selection of points for reconstruction of 3D configurations from two views.

OSTI ID:
20726236
Journal Information:
Medical Physics, Vol. 32, Issue 9; Other Information: DOI: 10.1118/1.2008467; (c) 2005 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Towards a theory of a solution space for the biplane imaging geometry problem
Journal Article · Sun Oct 15 00:00:00 EDT 2006 · Medical Physics · OSTI ID:20726236

Technique for Targeting Arteriovenous Malformations Using Frameless Image-Guided Robotic Radiosurgery
Journal Article · Tue Mar 15 00:00:00 EDT 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20726236

Binary reconstruction of the heart chambers from biplane angiographic image sequences
Journal Article · Thu Aug 01 00:00:00 EDT 1996 · IEEE Transactions on Medical Imaging · OSTI ID:20726236