Title: External respiratory motion for abdominal radiotherapy patients: implications for patient alignment

Journal Article · · Medical Dosimetry

Conformal external beam radiotherapy relies on accurate spatial positioning of the tumor and normal tissues during treatment. For abdominal patients, this is complicated by the motion of internal organs and the external patient contour due to respiration. As external motion influences the degree of accuracy achievable in patient setup, this motion was studied to provide indication of motions occurring during treatment, as well as to assess the technique of breath-holding at exhale (B-HEX). The motion of external abdominal points (anterior and right lateral) of a series of volunteers was tracked in real-time using an infrared tracking system, with the volunteers in treatment position. The resulting motion data was assessed to evaluate (1) the change in position of each point per breath/breath-hold, (2) the change in position between breaths/breath-holds, and (3) the change in position across the whole recording time. Analysis shows that, for the anterior abdominal point, there is little difference in the variation of position with time for free-breathing as opposed to the B-HEX technique. For the lateral point however, the B-HEX technique reduces the motion during each treatment cycle (i.e., during the breath-hold) and over an extended period (i.e., during a series of breath-holds). The B-HEX technique thus provides greater accuracy for setup to lateral markers and provides the opportunity to reduce systematic and random localization errors.

OSTI ID:
20655458
Journal Information:
Medical Dosimetry, Vol. 28, Issue 4; Other Information: DOI: 10.1016/j.meddos.2003.08.002; PII: S0958394703000931; Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved; Country of input: International Atomic Energy Agency (IAEA); ISSN 0958-3947
Country of Publication:
United States
Language:
English

Similar Records

SU-F-T-636: Comprehensive Approach to Motion Assessment for Liver and Pancreas SBRT Patients
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:20655458

MO-FG-CAMPUS-JeP3-04: Feasibility Study of Real-Time Ultrasound Monitoring for Abdominal Stereotactic Body Radiation Therapy
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:20655458

Accuracy and Consistency of Respiratory Gating in Abdominal Cancer Patients
Journal Article · Fri Mar 01 00:00:00 EST 2013 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20655458