Title: Low dose ionizing radiation detection using conjugated polymers

Journal Article · · Applied Physics Letters
DOI:https://doi.org/10.1063/1.1891300· OSTI ID:20637038
; ; ; ; ;  [1]
  1. Departamento de Fisica e Matematica, FFCLRP, Universidade de Sao Paulo, Av. Bandeirantes 3900, 14040-901 Ribeirao Preto, SP (Brazil)

In this work, the effect of gamma radiation on the optical properties of poly[2-methoxy-5-(2{sup '}-ethylhexyloxy)-p-phenylenevinylene] (MEH-PPV) is studied. The samples were irradiated at room temperature with different doses from 0 Gy to 152 Gy using a {sup 60}Co gamma ray source. For thin films, significant changes in the UV-visible spectra were only observed at high doses (>1 kGy). In solution, shifts in absorption peaks are observed at low doses (<10 Gy), linearly dependent on dose. The shifts are explained by conjugation reduction, and possible causes are discussed. Our results indicate that MEH-PPV solution can be used as a dosimeter adequate for medical applications.

OSTI ID:
20637038
Journal Information:
Applied Physics Letters, Vol. 86, Issue 13; Other Information: DOI: 10.1063/1.1891300; (c) 2005 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0003-6951
Country of Publication:
United States
Language:
English