Title: The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.1819789· OSTI ID:20634542
; ; ; ;  [1]
  1. Ontario Cancer Institute, Princess Margaret Hospital, Toronto, Ontario M5G 2M9, Canada, Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G 2M9, Canada, and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

The influence of antiscatter x-ray grids on image quality in cone-beam computed tomography (CT) is evaluated through broad experimental investigation for various anatomical sites (head and body), scatter conditions (scatter-to-primary ratio (SPR) ranging from {approx}10% to 150%), patient dose, and spatial resolution in three-dimensional reconstructions. Studies involved linear grids in combination with a flat-panel imager on a system for kilovoltage cone-beam CT imaging and guidance of radiation therapy. Grids were found to be effective in reducing x-ray scatter 'cupping' artifacts, with heavier grids providing increased image uniformity. The system was highly robust against ring artifacts that might arise in CT reconstructions as a result of gridline shadows in the projection data. The influence of grids on soft-tissue detectability was evaluated quantitatively in terms of absolute contrast, voxel noise, and contrast-to-noise ratio (CNR) in cone-beam CT reconstructions of 16 cm 'head' and 32 cm 'body' cylindrical phantoms. Imaging performance was investigated qualitatively in observer preference tests based on patient images (pelvis, abdomen, and head-and-neck sites) acquired with and without antiscatter grids. The results suggest that although grids reduce scatter artifacts and improve subject contrast, there is little strong motivation for the use of grids in cone-beam CT in terms of CNR and overall image quality under most circumstances. The results highlight the tradeoffs in contrast and noise imparted by grids, showing improved image quality with grids only under specific conditions of high x-ray scatter (SPR>100%), high imaging dose (D{sub center}>2 cGy), and low spatial resolution (voxel size {>=}1 mm)

OSTI ID:
20634542
Journal Information:
Medical Physics, Vol. 31, Issue 12; Other Information: DOI: 10.1118/1.1819789; (c) 2004 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English