skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Opacity incident reduction corrective action

Conference ·
OSTI ID:20013509

This paper illustrates some of the methods used to reduce the number of package boiler opacity incidents at the Consolidated Edison Company of New York, Inc. East River Generating Station. The principal objective was to reduce opacity exceedances caused by the design of boiler auxiliaries. Opacity causes were identified and grouped. A matrix was developed to keep track of repairs and corrections on all package boilers. A special maintenance program was developed to sustain opacity reduction.

Research Organization:
Consolidated Edison of New York (US)
OSTI ID:
20013509
Resource Relation:
Conference: 1998 International Joint Power Generation Conference, Baltimore, MD (US), 08/23/1998--08/26/1998; Other Information: PBD: 1998; Related Information: In: Proceedings of the 1998 international joint power generation conference (FACT-Vol.22). Volume 1: Fuels and combustion technologies; Gas turbines; Environmental engineering; Nuclear engineering, by Gupta, A.; Natole, R.; Sanyal, A.; Veilleux, J. [eds.], 921 pages.
Country of Publication:
United States
Language:
English