skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Four stage, fluidized bed gasification process minimizes NO{sub x}

Conference ·
OSTI ID:20006835

In 1981, after a long and thorough study of alternative methods of sewage sludge (biosolids) disposal, the City of Los Angeles (CLA) embarked on a pilot test program to incinerate dried sewage sludge from its Hyperion Wastewater Treatment Plant. This dried sludge is typically 47% ash, 53% combustible, and has an average higher heating value (HHV), moisture, ash-free (MAF) of 10,675 Btu/Lbm. The dried sludge is called sludge derived fuel (SDF). Approximately 8% of the MAF fraction of SDF is fuel-bound nitrogen. When SDF, with its extremely high fuel-bound nitrogen, was combusted in conventional multiple hearth and fluidized bed pilot plant furnaces, NO{sub x} emissions were extremely high ({gt}1,000 ppm). Faced with this dilemma, the CLA initiated an R and D program to reduce NO{sub x}. The pilot tests with a sub-stoichiometric fluid bed and an excess air afterburner (two-stages) reduced NO{sub x} to 400--600 ppm. With one intermediate stage added (three-stage), NO{sub x} was reduced to 130--150 ppm. However, when the following four-stage process was developed and tested, NO{sub x} was reduced to 50--75 ppm. Stage 1: Sub-stoichiometric fluidized bed operating at a nominal 30% stoichiometric air (SA). Stage 2:Sub-stoichiometric zone operating at a nominal 80% SA. Stage 3: Stoichiometric zone operating at a nominal 100% SA. Stage 4: Excess air zone (Afterburner) operating at a nominal 135% SA (35% excess air). After pilot testing was complete and design parameters established, three full-size, fluid bed gasifiers (two operational--one standby) were designed, constructed and operated until 1996. This paper describes the design, operation, and emission testing of these four-stage fluid bed gasifiers with special emphasis on the problems of (a) pneumatic feeding of SDF powder into the pressurized bed and (b) baghouse fabrics (expanded PTEE membrane on PTFE scrim). Final emission test results for NO{sub x} and other criteria pollutants are also presented.

Research Organization:
City of Los Angeles Dept. of Public Works, El Segundo, CA (US)
OSTI ID:
20006835
Report Number(s):
CONF-990534-; TRN: IM200008%%442
Resource Relation:
Conference: 15th International Conference on Fluidized Bed Combustion, Savannah, GA (US), 05/16/1999--05/19/1999; Other Information: 1 CD-ROM. Operating system required: Windows 3.x; Windows 95/98/NT; Macintosh, Power Macintosh; UNIX. All systems need 2X CD-ROM drive.; PBD: 1999; Related Information: In: Proceedings of the 15th national conference on fluidized bed combustion, by Reuther, R.B. [ed.], [1800] pages.
Country of Publication:
United States
Language:
English