Title: Common ``unique'' cavity wall flashing problems: Mistakes frequently made, their resolution, and presentations from case histories

Conference ·
OSTI ID:20000686

Building design drawings for masonry cavity wall construction generally attempt to contain most of the information needed to instruct the construction team on the types and placement of wall flashings. Some unique, low frequency conditions are often not described in detail in the drawings, and reliance is placed on the contractors to detail and install these unique flashing areas for watertight performance, using the concepts shown in the drawings for other areas. Frequently the resulting installation does not perform well, and leakage and disputes result. Sometimes subcontractor trades do not realize or anticipate how their work interfaces with another trade. Masonry flashings that are possibly installed in a water-tight and well-performing manner can be damaged by other trades who do not realize the damage being caused, and the resulting combination leaks. One example is the manner in which window heads are sometimes anchored or fastened to the underside of steel shelf angles which support brick masonry veneer above. This paper will discuss several examples of common leakage problems in masonry cavity wall construction, attributed to the above two concepts. The resolution of the problems, performed in recent case histories, will be presented, with suggestions for changes in original design drawings to help prevent the problems.

Research Organization:
Williamson and Associates, Inc., Atlanta, GA (US)
OSTI ID:
20000686
Report Number(s):
CONF-9804139-; ISBN 0-8031-2607-7
Resource Relation:
Conference: Water Problems in Building Exterior Walls: Evaluation, Prevention, and Repair, Atlanta, GA (US), 04/18/1998--04/19/1998; Other Information: PBD: 1999; Related Information: In: Water problems in building exterior walls: Evaluation, prevention, and repair. ASTM special technical publication 1352, by Boyd, J.M.; Scheffler, M.J. [eds.], 342 pages.
Country of Publication:
United States
Language:
English

Similar Records

Extraneous air leakage from window perimeters
Journal Article · Fri Sep 01 00:00:00 EDT 1995 · American Society for Testing and Materials, Special Technical Publication · OSTI ID:20000686

Replacement steel windows
Conference · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:20000686

The SURE House (Solar Decathlon 2015)
Technical Report · Tue Feb 21 00:00:00 EST 2017 · OSTI ID:20000686