Title: Thermal performance characterization of residential wall systems using a calibrated hot box with airflow induced by differential pressures

Journal Article · · American Society for Testing and Materials, Special Technical Publication
DOI:https://doi.org/10.1520/STP14698S· OSTI ID:170010
; ;  [1]
  1. Holometrix, Inc., Cambridge, MA (United States)

ASTM E 283 ad ASTM E 1424 in conjunction with ASTM C 976 were used to study the effect of airflow on thermal performance of the wall. A typical residential 2 {times} 4 stud wall was constructed and placed on top of a subfloor, making a 2.44 {times} 2.74 m (8 by 9 ft) test specimen. This base wall assembly was then covered with two types of XPS sheathing, various housewraps, a 15{number_sign} felt, and a polyethylene vapor retarder film in 40 different configurations and tested individually per ASTM E 283 and per ASTM C 976. For 24 of the 40 C 976 tests, a differential pressure was induced across the test wall as per and ASTM E 1424. Airflows ranged from undetectable airflow at 0 {center_dot} Pa {Delta}P to 1.63 L/s {center_dot} m{sup 2} for the base wall assembly alone. Difference in airflow resistance performance between the ASTM E 283 and ASTM E 1424 test methods were noted. Thermal testing results incorporating both ASTM C 976 and ASTM E 1424 for tests 1--28 produced apparent thermal conductances (C-values) in the range of 0.40 W/m{sup 2} {center_dot} K for a nondetectable airflow level to 1.81 W/m{sup 2} {center_dot} K for an airflow of 1.53 L/s {center_dot} m{sup 2} for the base wall assembly alone with a 20-Pa {Delta}P. The calculated C-value for this base wall assembly was 0.40 W/m{sup 2} {center_dot} K. Test results reveal that airflow rates as low as 0.2 L/s {center_dot} m{sup 2} could produce a 46% increase in apparent C-value. Similar thermal performance differences were revealed when thicker shiplap XPS sheathing was used. Tests were also conducted using an Air-Tight Drywall configuration showing the effect of wind washing on thermal performance. By sealing the gypsum drywall on the base wall assembly tested, the apparent C-value, when exposed to a 12.5 Pa wind pressure, was found to be equivalent to a base wall assembly configuration which allows 0.15 L/s {center_dot} m{sup 2} airflow to penetrate completely through.

Sponsoring Organization:
USDOE
OSTI ID:
170010
Report Number(s):
CONF-931017-; ISSN 0066-0558; TRN: IM9605%%29
Journal Information:
American Society for Testing and Materials, Special Technical Publication, Journal Issue: 1255; Conference: Symposium on airflow performance of building envelopes, components and systems, Fort Worth, TX (United States), 10-11 Oct 1993; Other Information: PBD: Sep 1995
Country of Publication:
United States
Language:
English

Similar Records

A wall and edge guarded hot box for thermal transmittance measurements
Conference · Sat Nov 01 00:00:00 EST 1997 · OSTI ID:170010

Combined Mesonet and Tracker
Dataset · Tue Mar 30 00:00:00 EDT 2021 · OSTI ID:170010

Fabrication of polyimide shells by vapor phase deposition for use as ICF targets