Table Mountain ozone intercomparison: Brewer ozone spectrophotometer Umkehr observations
Journal Article
·
· Journal of Geophysical Research
- Atmospheric Environment Service, Downsview (Canada)
The authors present the result of ozone column measurements, and vertical profiles, derived from Brewer ozone spectrophotometer measurements, in conjunction with the Umkehr technique. The Umkehr results agreed within 15% with the average measurments of this campaign between 20 and 40 km altitude. When restricted to the altitude range of 24 to 40 km the agreement was within about 5%.
- OSTI ID:
- 159771
- Journal Information:
- Journal of Geophysical Research, Vol. 100, Issue D5; Other Information: PBD: 20 May 1995