Title: Measuring fluid and slurry density and solids concentration non-invasively

Journal Article · · Ultrasonics, 42(1-9):563-567

Staff at Pacific Northwest National Laboratory have developed a highly sensitive, non-invasive, self calibrating, on-line sensor to measure the density, speed of sound, and attenuation of ultrasound for a liquid or slurry flowing through a pipeline; the approach can also be applied for measurements made in vessels. The sensor transducers are mounted directly upon the stainless steel wall and the pipeline wall becomes part of the measurement system. Multiple reflections within the stainless steel wall are used to determine the acoustic impedance of the liquid, where the acoustic impedance is defined as the product of the density and the speed of sound. The probe becomes self-calibrating because variations in the pulser voltage do not affect the measurements. This feature leads to the stability of the measurements and the instrument requires much less time and effort to calibrate. Further, the calibration remains constant in time, because it does not depend upon the pulser voltage remaining at a given value. By basing the measurement upon multiple reflections, the sensitivity of the measurement is significantly increased. For slurries with wt% solids concentration of 1% or less, high sensitivity is gained by analyzing attenuation measurements obtained from multiple paths through the slurry. For slurries with higher concentrations of solids, sufficient sensitivity is obtained by analyzing data from a simple transmission. Data are presented that show probe performance for each of these cases: very dilute and highly concentrated kaolin clay slurries.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC06-76RL01830
OSTI ID:
15007493
Report Number(s):
PNNL-SA-40035; 820201000
Journal Information:
Ultrasonics, 42(1-9):563-567, Journal Name: Ultrasonics, 42(1-9):563-567
Country of Publication:
United States
Language:
English

Similar Records

Non-invasive characterization of fluid foodstuffs based on ultrasonic measurements
Journal Article · Thu Jul 01 00:00:00 EDT 2004 · Food Research International · OSTI ID:15007493

Self-Calibrating Sensor for Measuring Density through Stainless Steel Pipeline Wall
Journal Article · Mon Mar 01 00:00:00 EST 2004 · Journal of Fluids Engineering--Transactions of the ASME, 126(2):189-192 · OSTI ID:15007493

Self-Calibrating Sensor for Measuring Density through Stainless Steel Pipeline Wall
Journal Article · Mon Mar 01 00:00:00 EST 2004 · Journal of Fluids Engineering--Transactions of the ASME, 126(2):189-192 · OSTI ID:15007493