Title: System Study: Isolation Condenser 1998–2013

Technical Report ·
DOI:https://doi.org/10.2172/1261718· OSTI ID:1261718
 [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States). Risk Assessment and Management Services Dept.

This report presents an unreliability evaluation of the isolation condenser (ISO) system at four U.S. boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the ISO results.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE; US Nuclear Regulatory Commission (NRC)
DOE Contract Number:
AC07-05ID14517; NRC-HQ-14-D-0018
OSTI ID:
1261718
Report Number(s):
INL/EXT-15-34437; TRN: US1601592
Country of Publication:
United States
Language:
English