Title: A US intercomparison of Josephson array voltage standards

Conference ·
OSTI ID:125779
 [1];  [2]
  1. Eastman Kodak Co., Rochester, NY (United States)
  2. Fluke Corp., Everett, WA (United States)

Qualification of intrinsic standards is a problem for laboratory accreditation systems. Accredited laboratories must demonstrate that their intrinsic standards actually provide the accuracy claimed. Ten standards laboratories have participated in an intercomparison of their 10 Volt Josephson Array Standards. The intercomparison program is described and results are presented.

OSTI ID:
125779
Report Number(s):
CONF-940603-; TRN: 95:005769-0150
Resource Relation:
Conference: CPEM `94: conference on precision electromagnetic measurements, Boulder, CO (United States), 27 Jun - 1 Jul 1994; Other Information: PBD: 1994; Related Information: Is Part Of 1994 Conference on precision electromagnetic measurements digest; DeWeese, E.; Bennett, G. [eds.]; PB: 577 p.
Country of Publication:
United States
Language:
English