Title: Technology Solutions for New and Existing Homes Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits

A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).
;  [1] ;  [1]
  1. NorthernSTAR Buidling American Partnership, Madison, WI (United States)
Publication Date:
OSTI Identifier:
Report Number(s):
Resource Type:
Technical Report
Research Org:
NorthernSTAR Buidling American Partnership, Madison, WI (United States)
Sponsoring Org:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Building America)
Country of Publication:
United States
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION residential; residential buildings; NorthernSTAR; Building America; slab-on-grade; insulation; energy; cost