Solvent Hold Tank Sample Results for MCU-16-270-271-272: February 2016 Monthly Sample
Abstract
Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-270-271-272), pulled on 02/21/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-270-271-272 indicated the IsoparTML concentration is above its nominal level (101%). The modifier (CS-7SB), the extractant (MaxCalix), and the TiDG concentrations are 7%, 6%, and 40% below their nominal concentrations. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in November 2015. Based on the current monthly sample, the levels of TiDG, IsoparTML, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.
- Authors:
-
- Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
- Publication Date:
- Research Org.:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 1254421
- Report Number(s):
- SRNL-STI-2016-00194
- DOE Contract Number:
- DE-AC09-08SR22470
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; MCU, ARP, ISDP NGS
Citation Formats
Fondeur, F. F., and Jones, D. H. Solvent Hold Tank Sample Results for MCU-16-270-271-272: February 2016 Monthly Sample. United States: N. p., 2016.
Web. doi:10.2172/1254421.
Fondeur, F. F., & Jones, D. H. Solvent Hold Tank Sample Results for MCU-16-270-271-272: February 2016 Monthly Sample. United States. https://doi.org/10.2172/1254421
Fondeur, F. F., and Jones, D. H. 2016.
"Solvent Hold Tank Sample Results for MCU-16-270-271-272: February 2016 Monthly Sample". United States. https://doi.org/10.2172/1254421. https://www.osti.gov/servlets/purl/1254421.
@article{osti_1254421,
title = {Solvent Hold Tank Sample Results for MCU-16-270-271-272: February 2016 Monthly Sample},
author = {Fondeur, F. F. and Jones, D. H.},
abstractNote = {Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-270-271-272), pulled on 02/21/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-270-271-272 indicated the IsoparTML concentration is above its nominal level (101%). The modifier (CS-7SB), the extractant (MaxCalix), and the TiDG concentrations are 7%, 6%, and 40% below their nominal concentrations. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in November 2015. Based on the current monthly sample, the levels of TiDG, IsoparTML, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.},
doi = {10.2172/1254421},
url = {https://www.osti.gov/biblio/1254421},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu May 12 00:00:00 EDT 2016},
month = {Thu May 12 00:00:00 EDT 2016}
}