Title: Airborne Open Polar/Imaging Nephelometer for Ice Particles in Cirrus Clouds and Aerosols Field Campaign Report

Abstract

The Open Imaging Nephelometer (O-I-Neph) instrument is an adaptation of a proven laboratory instrument built and tested at the University of Maryland, Baltimore County (UMBC), the Polarized Imaging Nephelometer (PI-Neph). The instrument design of both imaging nephelometers uses a narrow-beam laser source and a wide-field-of-view imaging camera to capture the entire scattering-phase function in one image, quasi-instantaneously.

Authors:
 [1]
  1. Univ. of Maryland, College Park, MD (United States)
Publication Date:
Research Org.:
DOE ARM Climate Research Facility, Washington, DC (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Biological and Environmental Research (BER)
OSTI Identifier:
1248493
Report Number(s):
DOE/SC-ARM-15-063
DOE Contract Number:  
AC05-7601830
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES

Citation Formats

Martins, JV. Airborne Open Polar/Imaging Nephelometer for Ice Particles in Cirrus Clouds and Aerosols Field Campaign Report. United States: N. p., 2016. Web. doi:10.2172/1248493.
Martins, JV. Airborne Open Polar/Imaging Nephelometer for Ice Particles in Cirrus Clouds and Aerosols Field Campaign Report. United States. https://doi.org/10.2172/1248493
Martins, JV. 2016. "Airborne Open Polar/Imaging Nephelometer for Ice Particles in Cirrus Clouds and Aerosols Field Campaign Report". United States. https://doi.org/10.2172/1248493. https://www.osti.gov/servlets/purl/1248493.
@article{osti_1248493,
title = {Airborne Open Polar/Imaging Nephelometer for Ice Particles in Cirrus Clouds and Aerosols Field Campaign Report},
author = {Martins, JV},
abstractNote = {The Open Imaging Nephelometer (O-I-Neph) instrument is an adaptation of a proven laboratory instrument built and tested at the University of Maryland, Baltimore County (UMBC), the Polarized Imaging Nephelometer (PI-Neph). The instrument design of both imaging nephelometers uses a narrow-beam laser source and a wide-field-of-view imaging camera to capture the entire scattering-phase function in one image, quasi-instantaneously.},
doi = {10.2172/1248493},
url = {https://www.osti.gov/biblio/1248493}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Apr 01 00:00:00 EDT 2016},
month = {Fri Apr 01 00:00:00 EDT 2016}
}