Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Indiana Univ., Bloomington, IN (United States)
Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.
- Research Organization:
- Indiana Univ., Bloomington, IN (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- Grant/Contract Number:
- NA0002012
- OSTI ID:
- 1366978
- Alternate ID(s):
- OSTI ID: 1247199
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 804; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Cited by: 4 works
Citation information provided by
Web of Science
Web of Science
Similar Records
Optimizing the position resolution of a Z-stack microchannel plate resistive anode detector for low intensity signals
Achieving high spatial resolution using a microchannel plate detector with an economic and scalable approach
Development of a compact microchannel plate detector for beam imaging
Journal Article
·
Sat Aug 15 00:00:00 EDT 2015
· Review of Scientific Instruments
·
OSTI ID:1366978
+2 more
Achieving high spatial resolution using a microchannel plate detector with an economic and scalable approach
Journal Article
·
Thu Aug 24 00:00:00 EDT 2017
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1366978
+3 more
Development of a compact microchannel plate detector for beam imaging
Journal Article
·
Sat Jun 17 00:00:00 EDT 2017
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1366978
+4 more