Title: Strategy Guideline. Modeling Enclosure Design in Above-Grade Walls

The Strategy Guideline, written by the U.S. Department of Energy's research team Building Science Corporation, 1) describes how to model and interpret results of models for above-grade walls, and 2) analyzes the failure thresholds and criteria for above-grade walls. A library of above-grade walls with historically successful performance was used to calibrate WUFI (Wärme und Feuchte instationär) software models. The information is generalized for application to a broad population of houses within the limits of existing experience.
;  [1] ;  [1]
  1. Building Science Corporation, Westford, MA (United States)
Publication Date:
OSTI Identifier:
Report Number(s):
Resource Type:
Technical Report
Research Org:
Building Science Corporation, Westford, MA (United States)
Sponsoring Org:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Building America)
Country of Publication:
United States
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION residential; residential buildings; building america; bsc; strategy guideline; wufi; above-grade walls