GADRAS is used to analyze gamma-ray spectra, which may be augmented by neutron count rate information. The fundamental capabilities of GADRAS are imparted by physics-based detector response functions for a variety of gamma ray and neufron detectors. The software has provisions for characterizing detector response parameters so that specta can be computed accurately over the range 30keV key to II MeV. Associated neutron detector count rates can also be computed for characterized detectors. GADRAS incorporates a variety of analysis algorithms that utilize the computed spectra. The full version of GADRAS incorporates support for computation of radiation leakages from complex source models, but this capability is not supported by GADRAS-LT. GADRAS has been and will continue to be disseminated free of charge to government agencies and National Laboratories as OUO software. GADRAS-LT is a limited software version that was prepared for exclusive use of our Technology Transfer parnter Thermo Electron (TE). TE will use the software to characterize and test radiation detectors that are fabricated under the terms of our partnership. The development of these sensors has been defined as a National Security priority by our sponsor, NNSA/NA-20, by DHS/S&T, and by SNL president Paul Robinson. Although GADRAS-LT is OUO, features that are not essential to the detector development have been removed. TE will not be licensed to commercialize GADRAS-LT or to distribute it to third parties.
To order this software or receive further information, please fill out the following request: Request Software
@misc{osti_1230739,
title = {Gamma Detector Response and Analysis Software - Light, Version 00},
author = {Mitchell, Dean J.},
abstractNote = {GADRAS is used to analyze gamma-ray spectra, which may be augmented by neutron count rate information. The fundamental capabilities of GADRAS are imparted by physics-based detector response functions for a variety of gamma ray and neufron detectors. The software has provisions for characterizing detector response parameters so that specta can be computed accurately over the range 30keV key to II MeV. Associated neutron detector count rates can also be computed for characterized detectors. GADRAS incorporates a variety of analysis algorithms that utilize the computed spectra. The full version of GADRAS incorporates support for computation of radiation leakages from complex source models, but this capability is not supported by GADRAS-LT. GADRAS has been and will continue to be disseminated free of charge to government agencies and National Laboratories as OUO software. GADRAS-LT is a limited software version that was prepared for exclusive use of our Technology Transfer parnter Thermo Electron (TE). TE will use the software to characterize and test radiation detectors that are fabricated under the terms of our partnership. The development of these sensors has been defined as a National Security priority by our sponsor, NNSA/NA-20, by DHS/S&T, and by SNL president Paul Robinson. Although GADRAS-LT is OUO, features that are not essential to the detector development have been removed. TE will not be licensed to commercialize GADRAS-LT or to distribute it to third parties.},
doi = {},
url = {https://www.osti.gov/biblio/1230739},
year = {Mon Jun 14 00:00:00 EDT 2004},
month = {Mon Jun 14 00:00:00 EDT 2004},
note =
}