Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function studies
Journal Article
·
· Journal of Applied Crystallography (Online)
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Brookhaven National Lab. (BNL), Upton, NY (United States); Columbia Univ., New York, NY (United States)
Different protocols for calibrating electron pair distribution function (ePDF) measurements are explored and described for quantitative studies on nanomaterials. It is found that the most accurate approach to determine the camera length is to use a standard calibration sample of Au nanoparticles from the National Institute of Standards and Technology. Different protocols for data collection are also explored, as are possible operational errors, to find the best approaches for accurate data collection for quantitative ePDF studies.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), Basic Energy Sciences (BES)
- DOE Contract Number:
- SC00112704
- OSTI ID:
- 1228940
- Report Number(s):
- BNL-111015-2015-JA; JACGAR
- Journal Information:
- Journal of Applied Crystallography (Online), Vol. 48, Issue 1; ISSN 1600-5767
- Publisher:
- International Union of Crystallography
- Country of Publication:
- United States
- Language:
- English
The chemistry of nucleation
|
journal | January 2016 |
Origin of the catalytic activity of face-centered-cubic ruthenium nanoparticles determined from an atomic-scale structure
|
journal | January 2016 |
Local atomic structure of thin and ultrathin films via rapid high-energy X-ray total scattering at grazing incidence
|
journal | February 2019 |
Local atomic structure of thin and ultrathin films via rapid high-energy X-ray total scattering at grazing incidence
|
text | January 2019 |
Similar Records
Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function studies
Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function (ePDF) studies
A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols
Journal Article
·
Fri Jan 30 00:00:00 EST 2015
· Journal of Applied Crystallography (Online)
·
OSTI ID:1228940
+2 more
Calibration and data collection protocols for reliable lattice parameter values in electron pair distribution function (ePDF) studies
Journal Article
·
Sun Feb 01 00:00:00 EST 2015
· Journal of Applied Crystallography (Online)
·
OSTI ID:1228940
+2 more
A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols
Journal Article
·
Sun Nov 15 00:00:00 EST 2015
· Medical Physics
·
OSTI ID:1228940
+9 more