Analysis of tank 7 surface supernatant sample (FTF-7-15-26) in support of corrosion control program
- Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
This report provides the results of analyses on Savannah River Site Tank 7 surface supernatant liquid sample in support of the Corrosion Control Program (CCP). The measured nitrate, nitrite and free-hydroxide concentrations for the Tank 7 surface sample averaged, 3.74E-01 ± 1.88E-03, 4.17E-01 ± 9.01E-03 and 0.602 ± 0.005 M, respectively. The Tank 7 surface cesium-137, sodium and silicon concentrations were, respectively, 3.99E+08, ± 3.25E+06 dpm/mL, 2.78 M and <3.10 mg/L. The measured aluminum concentration in the Tank 7 surface sample averaged 0.11 M.
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC09-08SR22470
- OSTI ID:
- 1225179
- Report Number(s):
- SRNL-STI-2015-00486; TRN: US1500855
- Country of Publication:
- United States
- Language:
- English
Similar Records
Analysis of tank 39H (HTF-39-15-61, 62) surface and subsurface supernatant samples in support of corrosion control program
Analysis of tank 4 (FTF-4-15-22, 23) surface and subsurface supernatant samples in support of enrichment control, corrosion control and evaporator feed qualification programs
Corrective Action Investigation Plan for Corrective Action Unit 543: Liquid Disposal Units Nevada Test Site, Nevada, Rev. No.: 0 with ROTC 1 and 2
Technical Report
·
Sat Aug 01 00:00:00 EDT 2015
·
OSTI ID:1225179
Analysis of tank 4 (FTF-4-15-22, 23) surface and subsurface supernatant samples in support of enrichment control, corrosion control and evaporator feed qualification programs
Technical Report
·
Wed Sep 09 00:00:00 EDT 2015
·
OSTI ID:1225179
Corrective Action Investigation Plan for Corrective Action Unit 543: Liquid Disposal Units Nevada Test Site, Nevada, Rev. No.: 0 with ROTC 1 and 2
Technical Report
·
Sat May 01 00:00:00 EDT 2004
·
OSTI ID:1225179
Related Subjects
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
TANKS
CESIUM 137
CORROSION PROTECTION
SODIUM
SAVANNAH RIVER PLANT
ABUNDANCE
ALUMINIUM
SILICON
HYDROXIDES
LIQUIDS
NITRATES
NITRITES
QUANTITATIVE CHEMICAL ANALYSIS
RADIOACTIVE WASTE PROCESSING
evaporator system supernatant liquid samples
characterization
tank farms
TANKS
CESIUM 137
CORROSION PROTECTION
SODIUM
SAVANNAH RIVER PLANT
ABUNDANCE
ALUMINIUM
SILICON
HYDROXIDES
LIQUIDS
NITRATES
NITRITES
QUANTITATIVE CHEMICAL ANALYSIS
RADIOACTIVE WASTE PROCESSING
evaporator system supernatant liquid samples
characterization
tank farms