Title: Technology Solutions Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.
Publication Date:
OSTI Identifier:
Report Number(s):
Research Org:
Building Science Corporation
Sponsoring Org:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Building America)
Country of Publication:
United States
Residential; Residential Buildings; BSC; Building America; Ventilation; Whole-building ventilation; Ventilation effectiveness; Ventilation air distribution; Ventilation air source; Ventilation system factors; Particulate; Particulate matter; Airborne particles; Formaldehyde; Volatile organic compound; VOC; TVOC; Indoor air quality​