skip to main content

SciTech ConnectSciTech Connect

Title: Multifamily Envelope Leakage Model

The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.
 [1] ;  [1]
  1. Consortium for Advanced Residential Buildings, Norwalk, CT (United States)
Publication Date:
OSTI Identifier:
Report Number(s):
DOE Contract Number:
Resource Type:
Technical Report
Research Org:
Consortium for Advanced Residential Buildings, Norwalk, CT (United States)
Sponsoring Org:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B)
Country of Publication:
United States
residential; Residential Buildings; CARB; Building America; blower door testing; envelope leakage; single-family attached housing; multifamily apartments; guarded; unguarded; predicting fully guarded test results; Building America; CARB; empirical model; multi-linear regression model