skip to main content

SciTech ConnectSciTech Connect

Title: Commissioning and Early Operation Experience of the NSLS-II Storage Ring RF System

The National Synchrotron Light Source II (NSLS-II) is a 3 GeV electron X-ray user facility commissioned in 2014. The storage ring RF system, essential for replenishing energy loss per turn of the electrons, consists of digital low level RF controllers, 310 kW CW klystron transmitters, CESR-B type superconducting cavities, as well as a supporting cryogenic system. Here we will report on RF commissioning and early operation experience of the system for beam current up to 200mA.
; ; ; ; ; ; ; ; ; ; ; ; ; ;
Publication Date:
OSTI Identifier:
Report Number(s):
R&D Project: LS001
DOE Contract Number:
Resource Type:
Resource Relation:
Conference: 6th International Particle Accelerator Conference; Newport News, Virginia; 20150503 through 20150508
Research Org:
Brookhaven National Laboratory (BNL), Upton, NY (United States). National Synchrotron Light Source II
Sponsoring Org:
USDOE Office of Science (SC)
Country of Publication:
United States
43 PARTICLE ACCELERATORS NSLS-II; klystron; cryogenic; National Synchrotron Light Source II