skip to main content

SciTech ConnectSciTech Connect

Title: CPLOAS_2 V2.10 verification report.

A series of test cases designed to verify the correct implementation of several features of the CPLOAS_2 program are documented. CPLOAS_2 is used to calculate the probability of loss of assured safety (PLOAS) for a weak link (WL)/strong link (SL) system. CPLOAS_2 takes physical properties (e.g., temperature, pressure, etc.) of a WL/SL system and uses these properties and definitions of link failure properties in probabilistic calculations to determine PLOAS. The features being tested include (i) six aleatory distribution forms, (ii) five numerical procedures for the determination of PLOAS (i.e., one quadrature procedure, two simple random sampling procedures, and two importance sampling procedures), and (iii) time and environmental margin calculations. All tests were performed with CPLOAS_2 version 2.10.
Publication Date:
OSTI Identifier:
Report Number(s):
DOE Contract Number:
Resource Type:
Technical Report
Research Org:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Org:
USDOE National Nuclear Security Administration (NNSA)
Country of Publication:
United States