skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Longitudinal emittance measurements in the Booster and AGS during the 2014 RHIC gold run

Technical Report ·
DOI:https://doi.org/10.2172/1154898· OSTI ID:1154898
 [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

This note describes longitudinal emittance measurements that were made in the Booster and AGS during the 2014 RHIC Gold run. It also contains an overview of the longitudinal aspects of their setup during this run. Each bunch intended for RHIC is composed of beam from 4 Booster cycles, and there are two of them per AGS cycle. For each of the 8 Booster cycles required to produce the 2 bunches in the AGS, a beam pulse from EVIS is injected into the Booster and captured in four h=4 buckets. Then those bunches are accelerated to a porch where they are merged into 2 bunches and then into 1 bunch.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
1154898
Report Number(s):
BNL-105988-2014-IR; BNL-C-A/AP/523; R&D Project: KBCH139; 18032; KB0202011; TRN: US1500117