Title: Hanford Single-Shell Tank Leak Causes and Locations - 241-T Farm

This document identifies 241-T Tank Farm (T Farm) leak causes and locations for the 100 series leaking tanks (241-T-106 and 241-T-111) identified in RPP-RPT-55084, Rev. 0, Hanford 241-T Farm Leak Inventory Assessment Report. This document satisfies the T Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
Publication Date:
OSTI Identifier:
Report Number(s):
RPP-RPT-54916 Rev. 0
DOE Contract Number:
Resource Type:
Technical Report
Research Org:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Org:
USDOE Office of Environmental Management (EM)
Contributing Orgs:
Washington River Protection Solutions, LLC
Country of Publication:
United States
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; 42 ENGINEERING leak location, leak cause, tank, integrity assessment, T Farm, T-106, T-111, leak assessment