Buffing, burnishing, and stripping of vinyl asbestos floor tile
- Environmental Protection Agency, Cincinnati, OH (United States); and others
Studies were conducted to evaluate airborne asbestos concentrations during the three principal types of preventative maintenance (low-speed spray-buffing, ultra high-speed burnishing, and wet-stripping) used on asbestos-containing floor tiles. These were done under pre-existing and prepared levels of floor care maintenance. Airborne asbestos concentrations were measured before and during each floor care procedure to determine the magnitude of the increase in airborne asbestos levels during each procedure. Airborne total fiber concentrations were also measured for comparison with the Occupational Safety and Health Administration`s (OSHA) Permissible Exposure Limit (PEL) of 0.1 f/cm{sup 3}. Low-speed spray-buffing and wet-stripping were evaluated on pre-existing floor conditions and three levels of prepared floor care conditions (poor, medium, and good). Ultra high-speed burnishing and wet-stripping were evaluated on two levels of prepared floor care conditions (poor and good). Floor care conditions were defined in consultation with the Chemical Specialty Manufacturers Association and other representatives of floor-care chemical manufacturers. Controlled studies were conducted in an unoccupied building at the decommissioned Chanute Air Force Base in Rantoul, Illinois, with the cooperation of the U.S. Air Force. The building offered approximately 8600 ft{sup 2} of open floor space tiled with 9-inch by 9-inch resilient floor tile containing approximately 5% chrysotile asbestos.
- OSTI ID:
- 111493
- Report Number(s):
- CONF-9504110-; TRN: 95:005009-0035
- Resource Relation:
- Conference: 21. Environmental Protection Agency (EPA) annual Risk Reduction Engineering Laboratory research symposium, Cincinnati, OH (United States), 4-6 Apr 1995; Other Information: PBD: 1995; Related Information: Is Part Of 21st Annual RREL research symposium: Abstract proceedings; PB: 398 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Carbon monoxide exposures from propane-powered floor burnishers following addition of emissions controls
In-depth survey report: evaluation of brake-drum service controls at Cincinnati Gas and Electric Garages, Cincinnati, Evanston, and Monroe, Ohio and Covington, Kentucky