Title: Calibration Monitoring for Sensor Calibration Interval Extension: Gaps in the Current Science Base

Conference ·

Currently in the United States, periodic sensor recalibration is required for all safety-related sensors, typically occurring at every refueling outage, and it has emerged as a critical path item for shortening outage duration in some plants. International application of calibration monitoring has shown that sensors may operate for longer periods within calibration tolerances. This issue is expected to also be important as the United States looks to the next generation of reactor designs (such as small modular reactors and advanced concepts), given the anticipated longer refueling cycles, proposed advanced sensors, and digital instrumentation and control systems. Online monitoring (OLM) can be employed to identify those sensors that require calibration, allowing for calibration of only those sensors that need it. The U.S. Nuclear Regulatory Commission (NRC) accepted the general concept of OLM for sensor calibration monitoring in 2000, but no U.S. plants have been granted the necessary license amendment to apply it. This paper summarizes a recent state-of-the-art assessment of online calibration monitoring in the nuclear power industry, including sensors, calibration practice, and OLM algorithms. This assessment identifies key research needs and gaps that prohibit integration of the NRC-approved online calibration monitoring system in the U.S. nuclear industry. Several technical needs were identified, including an understanding of the impacts of sensor degradation on measurements for both conventional and emerging sensors; the quantification of uncertainty in online calibration assessment; determination of calibration acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and assessment of the feasibility of using virtual sensor estimates to replace identified faulty sensors in order to extend operation to the next convenient maintenance opportunity.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1092028
Report Number(s):
PNNL-SA-90483; NT0107000
Resource Relation:
Conference: Future of Instrumentation International Workshop (FIIW 2012), October 8-9, 2012, Gaitlinburg, TN, 1-4
Country of Publication:
United States
Language:
English

Similar Records

A Review of Sensor Calibration Monitoring for Calibration Interval Extension in Nuclear Power Plants
Technical Report · Fri Aug 31 00:00:00 EDT 2012 · OSTI ID:1092028

Extending Sensor Calibration Intervals in Nuclear Power Plants
Journal Article · Thu Nov 15 00:00:00 EST 2012 · Transactions of the American Nuclear Society, 107:327-328 · OSTI ID:1092028

High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs