skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Monte Carlo Shielding Analysis Capabilities with MAVRIC

Journal Article · · Nuclear Technology
DOI:https://doi.org/10.13182/NT174-289· OSTI ID:1017290

Monte Carlo shielding analysis capabilities in SCALE 6 are centered on the CADIS methodology Consistent Adjoint Driven Importance Sampling. CADIS is used to create an importance map for space/energy weight windows as well as a biased source distribution. New to SCALE 6 are the Monaco functional module, a multi-group fixed-source Monte Carlo transport code, and the MAVRIC sequence (Monaco with Automated Variance Reduction Using Importance Calculations). MAVRIC uses the Denovo code (also new to SCALE 6) to compute coarse-mesh discrete ordinates solutions which are used by CADIS to form an importance map and biased source distribution for the Monaco Monte Carlo code. MAVRIC allows the user to optimize the Monaco calculation for a specify tally using the CADIS method with little extra input compared to a standard Monte Carlo calculation. When computing several tallies at once or a mesh tally over a large volume of space, an extension of the CADIS method called FW-CADIS can be used to help the Monte Carlo simulation spread particles over phase space to get more uniform relative uncertainties.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
Work for Others (WFO)
DOE Contract Number:
DE-AC05-00OR22725
OSTI ID:
1017290
Journal Information:
Nuclear Technology, Vol. 174, Issue 2; ISSN 0029-5450
Country of Publication:
United States
Language:
English