skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Post-test examination of a pool boiler receiver

Technical Report ·
OSTI ID:10154179

A subscale pool boiler test apparatus to evaluate boiling stability developed a leak after being operated with boiling NaK for 791.4 hr at temperatures from 700 to 750 {degrees}C. The boiler was constructed using Inconel 625 with a type 304L stainless steel wick for the boiler and type 316 stainless steel for the condenser. The boiler assembly was metallurgically evaluated to determine the cause of the leak and to assess the effects of the NaK on the materials. It was found that the leak was caused by insufficient (about 30 percent) joint penetration in a butt joint. There was no general corrosion of the construction materials, but the room temperature ductility of the Inconel 625 was only about 6.5 percent. A crack in the heat affected zone of the Inconel 625 near the Inconel 625 to type 316 stainless steel butt joint was probably caused by excessive heat input. The crack was observed to have a zone depleted of iron at the crack surface and porosity below that zone. The mechanism of the iron depletion was not conclusively determined. 3 refs.

Research Organization:
National Aeronautics and Space Administration, Cleveland, OH (United States). Lewis Research Center
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AT04-85AL33408
OSTI ID:
10154179
Report Number(s):
DOE/NASA-33408-6; NASA-TM-105635; ON: DE92015983
Resource Relation:
Other Information: PBD: Apr 1992
Country of Publication:
United States
Language:
English