Title: A contained sealed reflux dissolution apparatus for plutonium materials

Technical Report ·
OSTI ID:10140355

A containment apparatus has been designed and a procedure developed which permits the overnight operation in a tornado prone area of the sealed reflux dissolution system for the dissolution of hard-to-dissolve plutonium containing materials. A historical review of the development of the apparatus and the procedure used at the New Brunswick Laboratory is presented. The detailed operating procedure, the engineering drawings necessary to fabricate the apparatus, and the Safety Analysis Report containing a worst-case, single occurrence failure analysis are provided in the Appendices. 3 refs.

Research Organization:
USDOE New Brunswick Lab., Argonne, IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
OSTI ID:
10140355
Report Number(s):
NBL-325; ON: DE92013024; NC: NONE
Resource Relation:
Other Information: PBD: Dec 1991
Country of Publication:
United States