Title: Surface engineering of a Zr-based bulk metallic glass with low energy Ar- or Ca-ion implantation

Authors:
; ; ; ; ;
Publication Date:
Sponsoring Org.:
USDOE Office of Fossil Energy and Carbon Management (FECM)
OSTI Identifier:
1250382
Grant/Contract Number:  
AC02-06CH11357; NE0000693; 00119262; FE-0008855
Resource Type:
Publisher's Accepted Manuscript
Journal Name:
Materials Science and Engineering. C, Biomimetic Materials, Sensors and Systems
Additional Journal Information:
Journal Name: Materials Science and Engineering. C, Biomimetic Materials, Sensors and Systems Journal Volume: 47 Journal Issue: C; Journal ID: ISSN 0928-4931
Publisher:
Elsevier
Country of Publication:
Netherlands
Language:
English

Citation Formats

Huang, Lu, Zhu, Chao, Muntele, Claudiu I., Zhang, Tao, Liaw, Peter K., and He, Wei. Surface engineering of a Zr-based bulk metallic glass with low energy Ar- or Ca-ion implantation. Netherlands: N. p., 2015. Web. doi:10.1016/j.msec.2014.11.009.
Huang, Lu, Zhu, Chao, Muntele, Claudiu I., Zhang, Tao, Liaw, Peter K., & He, Wei. Surface engineering of a Zr-based bulk metallic glass with low energy Ar- or Ca-ion implantation. Netherlands. https://doi.org/10.1016/j.msec.2014.11.009
Huang, Lu, Zhu, Chao, Muntele, Claudiu I., Zhang, Tao, Liaw, Peter K., and He, Wei. Sun . "Surface engineering of a Zr-based bulk metallic glass with low energy Ar- or Ca-ion implantation". Netherlands. https://doi.org/10.1016/j.msec.2014.11.009.
@article{osti_1250382,
title = {Surface engineering of a Zr-based bulk metallic glass with low energy Ar- or Ca-ion implantation},
author = {Huang, Lu and Zhu, Chao and Muntele, Claudiu I. and Zhang, Tao and Liaw, Peter K. and He, Wei},
abstractNote = {},
doi = {10.1016/j.msec.2014.11.009},
journal = {Materials Science and Engineering. C, Biomimetic Materials, Sensors and Systems},
number = C,
volume = 47,
place = {Netherlands},
year = {Sun Feb 01 00:00:00 EST 2015},
month = {Sun Feb 01 00:00:00 EST 2015}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record
https://doi.org/10.1016/j.msec.2014.11.009

Citation Metrics:
Cited by: 11 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Influence of the irradiation temperature on the surface structure and physical/chemical properties of Ar ion-irradiated bulk metallic glasses
journal, October 2014


Synthesis of Fe–Cr–Mo–C–B–P bulk metallic glasses with high corrosion resistance
journal, February 2002


Correlation between corrosion performance and surface wettability in ZrTiCuNiBe bulk metallic glasses
journal, June 2010

  • Wang, Y. B.; Li, H. F.; Zheng, Y. F.
  • Applied Physics Letters, Vol. 96, Issue 25
  • DOI: 10.1063/1.3429591

Surface chemistry modulates focal adhesion composition and signaling through changes in integrin binding
journal, December 2004


Quantitative electron spectroscopy of surfaces: A standard data base for electron inelastic mean free paths in solids
journal, February 1979


Protein adsorption on titanium surfaces and their effect on osteoblast attachment
journal, September 2003

  • Yang, Yunzhi; Cavin, Renee; Ong, Joo L.
  • Journal of Biomedical Materials Research, Vol. 67A, Issue 1
  • DOI: 10.1002/jbm.a.10578

MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
journal, September 2009

  • Zberg, Bruno; Uggowitzer, Peter J.; Löffler, Jörg F.
  • Nature Materials, Vol. 8, Issue 11
  • DOI: 10.1038/nmat2542

Corrosion performances of a Nickel-free Fe-based bulk metallic glass in simulated body fluids
journal, November 2009


Bulk metallic glasses for biomedical applications
journal, September 2009


Ni-free Zr-Cu-Al-Nb-Pd bulk metallic glasses with different Zr/Cu ratios for biomedical applications
journal, June 2012

  • Huang, Lu; Yokoyama, Yoshihiko; Wu, Wei
  • Journal of Biomedical Materials Research Part B: Applied Biomaterials, Vol. 100B, Issue 6
  • DOI: 10.1002/jbm.b.32715

Role of material surfaces in regulating bone and cartilage cell response
journal, January 1996


Surface modification and biocompatibility of Ni-free Zr-based bulk metallic glass
journal, February 2008


Wear resistance of Zr-based bulk metallic glass applied in bearing rollers
journal, November 2004


Surface modification of titanium, titanium alloys, and related materials for biomedical applications
journal, December 2004


In vivo metallic biomaterials and surface modification
journal, July 1999


Effect of Ar+ ion irradiation on the microstructure and properties of Zr–Cu–Fe–Al bulk metallic glass
journal, April 2011


Enhancing the bio-corrosion resistance of Ni-free ZrCuFeAl bulk metallic glass through nitrogen plasma immersion ion implantation
journal, December 2014


The Nature of the Mineral Phase of Bone.
journal, August 1953


Surface analysis, hydrophilic enhancement, ageing behavior and flow in plasma modified cyclic olefin copolymer (COC)-based microfluidic devices
journal, October 2010


Microstructure and electrochemical behavior of Ti-coatedZr55Al10Ni5Cu30 bulk metallic glass
journal, November 2009


Hardness and shear band evolution in bulk metallic glasses after plastic deformation and annealing
journal, October 2008


A Ni-free ZrCuFeAlAg bulk metallic glass with potential for biomedical applications
journal, June 2013


Nanomoulding with amorphous metals
journal, February 2009

  • Kumar, Golden; Tang, Hong X.; Schroers, Jan
  • Nature, Vol. 457, Issue 7231
  • DOI: 10.1038/nature07718

Tribological properties of bulk metallic glasses
journal, July 2004


Biodegradable CaMgZn bulk metallic glass for potential skeletal application
journal, August 2011


Study on bio-corrosion and cytotoxicity of a sr-based bulk metallic glass as potential biodegradable metal
journal, November 2011

  • Li, H. F.; Zhao, K.; Wang, Y. B.
  • Journal of Biomedical Materials Research Part B: Applied Biomaterials, Vol. 100B, Issue 2
  • DOI: 10.1002/jbm.b.31958

Engineering Cellular Response Using Nanopatterned Bulk Metallic Glass
journal, April 2014

  • Padmanabhan, Jagannath; Kinser, Emily R.; Stalter, Mark A.
  • ACS Nano, Vol. 8, Issue 5
  • DOI: 10.1021/nn501874q

Responses of bone-forming cells on pre-immersed Zr-based bulk metallic glasses: Effects of composition and roughness
journal, January 2011


Ion implantation of titanium based biomaterials
journal, October 2011


Vinculin controls focal adhesion formation by direct interactions with talin and actin
journal, December 2007

  • Humphries, Jonathan D.; Wang, Pengbo; Streuli, Charles
  • Journal of Cell Biology, Vol. 179, Issue 5
  • DOI: 10.1083/jcb.200703036

The effect of Nb addition on mechanical properties, corrosion behavior, and metal-ion release of ZrAlCuNi bulk metallic glasses in artificial body fluid
journal, January 2005

  • Qiu, C. L.; Liu, L.; Sun, M.
  • Journal of Biomedical Materials Research Part A, Vol. 75A, Issue 4
  • DOI: 10.1002/jbm.a.30502

Amorphous metals for hard-tissue prosthesis
journal, February 2010


Bio-corrosion study on zirconium-based bulk-metallic glasses
journal, April 2009


Quantitative Evaluation of the Photoinduced Hydrophilic Conversion Properties of TiO 2 Thin Film Surfaces by the Reciprocal of Contact Angle
journal, January 2003

  • Sakai, Nobuyuki; Fujishima, Akira; Watanabe, Toshiya
  • The Journal of Physical Chemistry B, Vol. 107, Issue 4
  • DOI: 10.1021/jp022105p

Effects of calcium ion implantation on human bone cell interaction with titanium
journal, August 2005


On the adsorption of proteins on solid surfaces, a common but very complicated phenomenon
journal, January 2001

  • Nakanishi, Kazuhiro; Sakiyama, Takaharu; Imamura, Koreyoshi
  • Journal of Bioscience and Bioengineering, Vol. 91, Issue 3
  • DOI: 10.1016/S1389-1723(01)80127-4

Effect of surface topography and chemistry on adhesion, orientation and growth of fibroblasts on nickel–titanium substrates
journal, September 2002