Potentiometric Response Characteristics of Membrane-Based -Selective Electrodes Containing Ionophore-Functionalized Polymeric Microspheres
Abstract
Cs + -selective solvent polymeric membrane-based ion-selective electrodes (ISEs) were developed by doping ethylene glycol-functionalized cross-linked polystyrene microspheres (P-EG) into a plasticized poly(vinyl chloride) (PVC) matrix containing sodium tetrakis-(3,5-bis(trifluoromethyl)phenyl) borate (TFPB) as the ion exchanger. A systematic study examining the effects of the membrane plasticizers bis(2-ethylhexyl) sebacate (DOS), 2-nitrophenyl octyl ether (NPOE), and 2-fluorophenyl nitrophenyl ether (FPNPE) on the potentiometric response and selectivity of the corresponding electrodes was performed. Under certain conditions, P-EG-based ion-selective electrodes (ISEs) containing TFPB and plasticized with NPOE exhibited a super-Nernstian response between and M Cs + , a response characteristic not observed in analogous membranes plasticized with either DOS or FPNPE. Additionally, the performance of P-EG-based ISEs was compared to electrodes based on two mobile ionophores, a neutral lipophilic ethylene glycol derivative (ethylene glycol monooctadecyl ether (U-EG)) and a charged metallacarborane ionophore, sodium bis(dicarbollyl)cobaltate(III) (CC). In general, P-EG-based electrodes plasticized with FPNPE yielded the best performance, with a linear range from 10 -1 –10 -5 M Cs + , a conventional lower detection limit of M Cs + , and a response slope of 57.7 mV/decade. The pH response of P-EG ISEs containing TFPB was evaluated for membranes plasticized with either NPOE or FPNPE. In both cases, the electrodes remained stable throughout the pH range 3–12, with only slight proton interference observed below pH 3.
- Authors:
-
- Chemistry Division, Los Alamos National Laboratory, Los Alamos, NM 87545, USA, Radiochemical Analysis Group, Chemical & Physical Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99354, USA
- Chemistry Division, Los Alamos National Laboratory, Los Alamos, NM 87545, USA
- Publication Date:
- Sponsoring Org.:
- USDOE
- OSTI Identifier:
- 1198259
- Resource Type:
- Published Article
- Journal Name:
- International Journal of Electrochemistry
- Additional Journal Information:
- Journal Name: International Journal of Electrochemistry Journal Volume: 2011; Journal ID: ISSN 2090-3537
- Publisher:
- Hindawi Publishing Corporation
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Citation Formats
Peper, Shane, and Gonczy, Chad. Potentiometric Response Characteristics of Membrane-Based Cs + -Selective Electrodes Containing Ionophore-Functionalized Polymeric Microspheres. Country unknown/Code not available: N. p., 2011.
Web. doi:10.4061/2011/276896.
Peper, Shane, & Gonczy, Chad. Potentiometric Response Characteristics of Membrane-Based Cs + -Selective Electrodes Containing Ionophore-Functionalized Polymeric Microspheres. Country unknown/Code not available. https://doi.org/10.4061/2011/276896
Peper, Shane, and Gonczy, Chad. Sat .
"Potentiometric Response Characteristics of Membrane-Based Cs + -Selective Electrodes Containing Ionophore-Functionalized Polymeric Microspheres". Country unknown/Code not available. https://doi.org/10.4061/2011/276896.
@article{osti_1198259,
title = {Potentiometric Response Characteristics of Membrane-Based Cs + -Selective Electrodes Containing Ionophore-Functionalized Polymeric Microspheres},
author = {Peper, Shane and Gonczy, Chad},
abstractNote = {Cs + -selective solvent polymeric membrane-based ion-selective electrodes (ISEs) were developed by doping ethylene glycol-functionalized cross-linked polystyrene microspheres (P-EG) into a plasticized poly(vinyl chloride) (PVC) matrix containing sodium tetrakis-(3,5-bis(trifluoromethyl)phenyl) borate (TFPB) as the ion exchanger. A systematic study examining the effects of the membrane plasticizers bis(2-ethylhexyl) sebacate (DOS), 2-nitrophenyl octyl ether (NPOE), and 2-fluorophenyl nitrophenyl ether (FPNPE) on the potentiometric response and selectivity of the corresponding electrodes was performed. Under certain conditions, P-EG-based ion-selective electrodes (ISEs) containing TFPB and plasticized with NPOE exhibited a super-Nernstian response between 1 × 10 − 3 and 1 × 10 − 4 M Cs + , a response characteristic not observed in analogous membranes plasticized with either DOS or FPNPE. Additionally, the performance of P-EG-based ISEs was compared to electrodes based on two mobile ionophores, a neutral lipophilic ethylene glycol derivative (ethylene glycol monooctadecyl ether (U-EG)) and a charged metallacarborane ionophore, sodium bis(dicarbollyl)cobaltate(III) (CC). In general, P-EG-based electrodes plasticized with FPNPE yielded the best performance, with a linear range from 10 -1 –10 -5 M Cs + , a conventional lower detection limit of 8.1 × 10 − 6 M Cs + , and a response slope of 57.7 mV/decade. The pH response of P-EG ISEs containing TFPB was evaluated for membranes plasticized with either NPOE or FPNPE. In both cases, the electrodes remained stable throughout the pH range 3–12, with only slight proton interference observed below pH 3.},
doi = {10.4061/2011/276896},
journal = {International Journal of Electrochemistry},
number = ,
volume = 2011,
place = {Country unknown/Code not available},
year = {Sat Jan 01 00:00:00 EST 2011},
month = {Sat Jan 01 00:00:00 EST 2011}
}
https://doi.org/10.4061/2011/276896
Works referenced in this record:
Development and demonstration of solvent extraction processes for the separation of radionuclides from acidic radioactive waste
journal, February 1999
- Law, J. D.; Brewer, K. N.; Herbst, R. S.
- Waste Management, Vol. 19, Issue 1
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics
journal, December 1997
- Bakker, Eric; Bühlmann, Philippe; Pretsch, Ernö
- Chemical Reviews, Vol. 97, Issue 8, p. 3083-3132
Polymer Membrane Ion-Selective Electrodes-What are the Limits?
journal, September 1999
- Bakker, Eric; Bühlmann, Philippe; Pretsch, Ernö
- Electroanalysis, Vol. 11, Issue 13
Properties of PVC based membranes used in ion-selective electrodes
journal, January 1990
- Armstrong, R. D.; Horvai, G.
- Electrochimica Acta, Vol. 35, Issue 1
Plasticizers for liquid polymeric membranes of ion-selective chemical sensors
journal, April 1994
- Eugster, Rudolf; Rosatzin, Thomas; Rusterholz, Bruno
- Analytica Chimica Acta, Vol. 289, Issue 1
Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors
journal, June 1998
- Bühlmann, Philippe; Pretsch, Ernö; Bakker, Eric
- Chemical Reviews, Vol. 98, Issue 4
The Universal Solvent Extraction (Unex) Process. i. Development of the unex Process Solvent for the Separation of Cesium, Strontium, and the Actinides from Acidic Radioactive Waste
journal, January 2001
- Romanovskiy, Valeriy N.; Smirnov, Igor V.; Babain, Vasily A.
- Solvent Extraction and Ion Exchange, Vol. 19, Issue 1