Powered by Deep Web Technologies
Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Volker Rose  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Dr. Volker Rose holds an advanced degree in physics (Dipl.-Phys.) and received a doctoral degree Dr. Volker Rose holds an advanced degree in physics (Dipl.-Phys.) and received a doctoral degree (Dr.rer.nat.) from RWTH Aachen, Germany in 2005. During this time he conducted research at Research Center Julich, the largest interdisciplinary research center in Europe. After a postdoctoral appointment at the Center for Nanoscale Materials (CNM), he joined the Microscopy Group at the Advanced Photon

2

Argonne CNM News: Volker Rose Receives 2012 DOE Early Career Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Volker Rose Receives 2012 DOE Early Career Research Program Award Volker Rose Receives 2012 DOE Early Career Research Program Award Volker Rose Volker Rose with the prototype high-resolution microscope at the APS/CNM nanoprobe beamline on APS Sector 26. Volker Rose, assistant physicist with the U.S. Department of Energy (DOE) Office of Science's Advanced Photon Source X-Ray Science Division (XSD) and the Center for Nanoscale Materials (CNM) at Argonne National Laboratory, is one of four Argonne researchers who have received 2012 Early Career Research Program awards, granted by DOE to exceptional researchers beginning their careers. "Argonne is extremely proud that four of our young researchers have been chosen for this important award," said Eric D. Isaacs, Argonne Director. "These young scientists and engineers will play a vital role in our nation's future, helping to assure that invention and innovation continue to fuel America's global competitiveness in the years to come."

3

2011 U.S. National School on Neutron and X-ray Scattering  

SciTech Connect (OSTI)

The 13th annual U.S. National School on Neutron and X-ray Scattering was held June 11 to 25, 2011, at both Oak Ridge and Argonne National Laboratories. This school brought together 65 early career graduate students from 56 different universities in the US and provided them with a broad introduction to the techniques available at the major large-scale neutron and synchrotron x-ray facilities. This school is focused primarily on techniques relevant to the physical sciences, but also touches on cross-disciplinary bio-related scattering measurements. During the school, students received lectures by over 30 researchers from academia, industry, and national laboratories and participated in a number of short demonstration experiments at Argonne's Advanced Photon Source (APS) and Oak Ridge's Spallation neutron Source (SNS) and High Flux Isotope Reactor (HFIR) facilities to get hands-on experience in using neutron and synchrotron sources. The first week of this year's school was held at Oak Ridge National Lab, where Lab director Thom Mason welcomed the students and provided a shitorical perspective of the neutron and x-ray facilities both at Oak Ridge and Argonne. The first few days of the school were dedicated to lectures laying out the basics of scattering theory and the differences and complementarity between the neutron and x-ray probes given by Sunil Sinha. Jack Carpenter provided an introduction into how neutrons are generated and detected. After this basic introduction, the students received lectures each morning on specific techniques and conducted demonstration experiments each afternoon on one of 15 different instruments at either the SNS or HFIR. Some of the topics covered during this week of the school included inelastic neutron scattering by Bruce Gaulin, x-ray and neutron reflectivity by Chuck Majkrazak, small-angle scattering by Volker Urban, powder diffraction by Ashfia Huq and diffuse scattering by Gene Ice.

Lang, Jonathan [Argonne National Laboratory (ANL); te Vethuis, Suzanne [Argonne National Laboratory (ANL); Ekkebus, Allen E [ORNL; Chakoumakos, Bryan C [ORNL; Budai, John D [ORNL

2012-01-01T23:59:59.000Z

4

Chest x-Rays  

Broader source: Energy.gov [DOE]

The B-reading is a special reading of a standard chest x-ray film performed by a physician certified by the National Institute for Occupational Safety and Health (NIOSH). The reading looks for changes on the chest x-ray that may indicate exposure and disease caused by agents such as asbestos or silica.

5

X-ray beamsplitter  

DOE Patents [OSTI]

An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5--50 pairs of alternate Mo/Si layers with a period of 20--250 A. The support membrane is 10--200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window. 6 figs.

Ceglio, N.M.; Stearns, D.G.; Hawryluk, A.M.; Barbee, T.W. Jr.

1987-08-07T23:59:59.000Z

6

X-ray beamsplitter  

DOE Patents [OSTI]

An x-ray beamsplitter which splits an x-ray beam into two coherent parts by reflecting and transmitting some fraction of an incident beam has applications for x-ray interferometry, x-ray holography, x-ray beam manipulation, and x-ray laser cavity output couplers. The beamsplitter is formed of a wavelength selective multilayer thin film supported by a very thin x-ray transparent membrane. The beamsplitter resonantly transmits and reflects x-rays through thin film interference effects. A thin film is formed of 5-50 pairs of alternate Mo/Si layers with a period of 20-250 A. The support membrane is 10-200 nm of silicon nitride or boron nitride. The multilayer/support membrane structure is formed across a window in a substrate by first forming the structure on a solid substrate and then forming a window in the substrate to leave a free-standing structure over the window.

Ceglio, Natale M. (Livermore, CA); Stearns, Daniel S. (Mountain View, CA); Hawryluk, Andrew M. (Modesto, CA); Barbee, Jr., Troy W. (Palo Alto, CA)

1989-01-01T23:59:59.000Z

7

X-ray binaries  

E-Print Network [OSTI]

We review the nuclear astrophysics aspects of accreting neutron stars in X-ray binaries. We summarize open astrophysical questions in light of recent observations and their relation to the underlying nuclear physics. Recent progress in the understanding of the nuclear physics, especially of X-ray bursts, is also discussed.

H. Schatz; K. E. Rehm

2006-08-01T23:59:59.000Z

8

X-ray laser  

DOE Patents [OSTI]

An X-ray laser (10) that lases between the K edges of carbon and oxygen, i.e. between 44 and 23 Angstroms, is provided. The laser comprises a silicon (12) and dysprosium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state nickel-like dysprosium ions (34) are resonantly photo-pumped to their upper X-ray laser state by line emission from hydrogen-like silicon ions (32). The novel X-ray laser should prove especially useful for the microscopy of biological specimens.

Nilsen, Joseph (Livermore, CA)

1991-01-01T23:59:59.000Z

9

Scientists combine X-rays and microscopes for precise experiments | Argonne  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

This insulator-coated "smart tip" for synchrotron X-ray scanning tunneling microscopy confines the signal detection to a tiny region of a sample. The nanofabricated tips have been developed by an Argonne team led by Argonne nanoscientist Volker Rose to improve the sensitivity of the SXSTM technique. To view a larger version of the image, click on it. This insulator-coated "smart tip" for synchrotron X-ray scanning tunneling microscopy confines the signal detection to a tiny region of a sample. The nanofabricated tips have been developed by an Argonne team led by Argonne nanoscientist Volker Rose to improve the sensitivity of the SXSTM technique. To view a larger version of the image, click on it. This insulator-coated "smart tip" for synchrotron X-ray scanning tunneling microscopy confines the signal detection to a tiny region of a sample. The nanofabricated tips have been developed by an Argonne team led by Argonne nanoscientist Volker Rose to improve the sensitivity of the SXSTM technique. To view a larger version of the image, click on it. Scientists combine X-rays and microscopes for precise experiments

10

X-ray absorption spectroscopy  

E-Print Network [OSTI]

009-9473-8 REVIEW X-ray absorption spectroscopy Junko Yano Æand application of X-ray absorption spectroscopy, bothX-ray absorption near-edge structure (XANES) and extended X-

Yano, Junko; Yachandra, Vittal K.

2009-01-01T23:59:59.000Z

11

X-ray Absorption Spectroscopy  

E-Print Network [OSTI]

type: Review X-ray Absorption Spectroscopy Junko Yano andPhotosystem II; XAS, X-ray absorption spectroscopy; EXAFS,X-ray absorption fine structure; EPR, electron paramagnetic

Yano, Junko

2010-01-01T23:59:59.000Z

12

X-Ray Generators  

Science Journals Connector (OSTI)

There are many types of X-ray generators sold commercially. The following are some of ... that should be considered when selecting a particular generator for a particular purpose. All the companies listed below s...

Reuben Rudman

1972-01-01T23:59:59.000Z

13

X-ray beam finder  

DOE Patents [OSTI]

An X-ray beam finder for locating a focal spot of an X-ray tube includes a mass of X-ray opaque material having first and second axially-aligned, parallel-opposed faces connected by a plurality of substantially identical parallel holes perpendicular to the faces and a film holder for holding X-ray sensitive film tightly against one face while the other face is placed in contact with the window of an X-ray head.

Gilbert, H.W.

1983-06-16T23:59:59.000Z

14

X-ray Spectrometry  

Science Journals Connector (OSTI)

These provide excellent energy resolution for a wide range of X-ray energies, from the optical range up to several kiloelectronvolts. ... The Astro-E2 launched in 2005 was the first mission that contained a low-temperature microcalorimeter-based observatory, and three more low-temperature detector-based observatories are being developed (NeXT, Constellation-X, ZEUS). ...

Imre Szalóki; János Osán; René E. Van Grieken

2006-05-10T23:59:59.000Z

15

Tunable X-ray source  

DOE Patents [OSTI]

A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

Boyce, James R. (Williamsburg, VA)

2011-02-08T23:59:59.000Z

16

X-ray Spectrometry  

Science Journals Connector (OSTI)

The segmented STJ operated at total count rates of above 105 counts/s, and the best-achieved energy resolution of their single STJ was found to be 10 eV for X-ray energies below 1 keV. ... The Mo?Au TES, with an operating temperature of 230 mK, was developed for the Constellation-X mission and the energy resolution of the spectrometer is ?28 eV at 3.3 keV. ...

Imre Szalóki; Szabina B. Török; Jasna Injuk; René E. Van Grieken

2002-05-18T23:59:59.000Z

17

Volker Urban | Photosynthetic Antenna Research Center  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

61511:: ORNL Neutrons, Supercomputer Simulations Reveal Molecular Structure of Lignin 92211:: ORNL discovers amazing electrical properties in polymers 92511:: Polymers...

18

X-ray Absorption Spectroscopy  

SciTech Connect (OSTI)

This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

Yano, Junko; Yachandra, Vittal K.

2009-07-09T23:59:59.000Z

19

X-ray fluorescence mapping  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

biololgical cells, over the measurement of impurities in solar cells, to the rare earth content of geological materials. A somewhat 'typical' layout for a X-ray fluorescence...

20

X-ray shearing interferometer  

DOE Patents [OSTI]

An x-ray interferometer for analyzing high density plasmas and optically opaque materials includes a point-like x-ray source for providing a broadband x-ray source. The x-rays are directed through a target material and then are reflected by a high-quality ellipsoidally-bent imaging crystal to a diffraction grating disposed at 1.times. magnification. A spherically-bent imaging crystal is employed when the x-rays that are incident on the crystal surface are normal to that surface. The diffraction grating produces multiple beams which interfere with one another to produce an interference pattern which contains information about the target. A detector is disposed at the position of the image of the target produced by the interfering beams.

Koch, Jeffrey A. (Livermore, CA)

2003-07-08T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Optics for X-Ray Laser and Laser Plasma Soft X-Ray Radiation  

Science Journals Connector (OSTI)

Focusing X-ray grazing incidence optics for X-ray laser and laser plasma soft X-ray radiation has been studied. ... computer code. Parabolic axisymmetric mirror for focusing Princeton X-ray laser beam and ellipso...

L. Pina; A. Inneman; R. Hudec

1996-01-01T23:59:59.000Z

22

SMB, X-Ray Spectroscopy & Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home X-Ray Spectroscopy & Imaging X-Ray Spectroscopy & Imaging SSRL has five hard X-ray Spectroscopy beamlines and three Microfocus Imaging beamlines dedicated to Biological and...

23

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lensless X-Ray Imaging in Reflection Lensless X-Ray Imaging in Reflection Print Wednesday, 26 October 2011 00:00 The advent of x-ray free-electron laser (XFEL) light sources has...

24

X-ray Imaging Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Imaging and Spectro-microscopy: Imaging and Spectro-microscopy: the Present and the Future Stanford Synchrotron Radiation Laboratory October 8-9, 2002 Organizers: John Miao & Keith Hodgson A workshop on "X-ray Imaging and Spectro-microscopy: the Present and the Future" was held on October 8-9, 2002. This workshop, organized by John Miao (SSRL) and Keith Hodgson (SSRL) provided a forum to discuss the scientific applications of a variety of imaging and spectro-microscopic techniques, including photoemission electron microscopy (PEEM), angle resolved photoemission spectroscopy (ARPES), coherent diffraction imaging, x-ray microscopy, micro-tomography, holographic imaging, and x-ray micro-probe. Twelve invited speakers discussed the important scientific applications of these techniques, and also predicted the future scientific directions with the advance of instrumentation and x-ray sources. The workshop was well attended with over fifty registered attendees.

25

Miniature x-ray source  

DOE Patents [OSTI]

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

Trebes, James E. (Livermore, CA); Bell, Perry M. (Tracy, CA); Robinson, Ronald B. (Modesto, CA)

2000-01-01T23:59:59.000Z

26

Center for X-Ray Optics, 1992  

SciTech Connect (OSTI)

This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors.

Not Available

1993-08-01T23:59:59.000Z

27

X-ray Stacking 2008-Apr-22 Astrostats X-ray Stacking  

E-Print Network [OSTI]

X-ray Stacking 2008-Apr-22 Astrostats X-ray Stacking Tom Aldcroft SAO/CXC #12;X-ray Stacking 2008 analysis for a sample Stacking ­ mean properties of sample Chandra X-ray data (faint point sources) are photon-limited with low background => stacking in X-rays is very effective #12;X-ray Stacking 2008-Apr-22

Wolfe, Patrick J.

28

Center for X-Ray Optics, 1991  

SciTech Connect (OSTI)

This report discusses: Soft-X-Ray imaging with zone-plate lenses; multilayer reflective optics; and spectroscopy with x-rays.

Not Available

1992-03-01T23:59:59.000Z

29

SMB, X-ray Absorption Spectroscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Absorption Spectroscopy X-ray Absorption Spectroscopy X-ray absorption spectroscopy (XAS) is a well-established technique for simultaneous local geometric and electronic structure...

30

Tokamak x ray diagnostic instrumentation  

SciTech Connect (OSTI)

Three classes of x-ray diagnostic instruments enable measurement of a variety of tokamak physics parameters from different features of the x-ray emission spectrum. (1) The soft x-ray (1 to 50 keV) pulse-height-analysis (PHA) diagnostic measures impurity concentrations from characteristic line intensities and the continuum enhancement, and measures the electron temperature from the continuum slope. (2) The Bragg x-ray crystal spectrometer (XCS) measures the ion temperature and neutral-beam-induced toroidal rotation velocity from the Doppler broadening and wavelength shift, respectively, of spectral lines of medium-Z impurity ions. Impurity charge state distributions, precise wavelengths, and inner-shell excitation and recombination rates can also be studied. X rays are diffracted and focused by a bent crystal onto a position-sensitive detector. The spectral resolving power E/..delta..E is greater than 10/sup 4/ and time resolution is 10 ms. (3) The x-ray imaging system (XIS) measures the spatial structure of rapid fluctuations (0.1 to 100 kHZ) providing information on MHD phenomena, impurity transport rates, toroidal rotation velocity, plasma position, and the electron temperature profile. It uses an array of silicon surface-barrier diodes which view different chords of the plasma through a common slot aperture and operate in current (as opposed to counting) mode. The effectiveness of shields to protect detectors from fusion-neutron radiation effects has been studied both theoretically and experimentally.

Hill, K.W.; Beiersdorfer, P.; Bitter, M.; Fredrickson, E.; Von Goeler, S.; Hsuan, H.; Johnson, L.C.; Liew, S.L.; McGuire, K.; Pare, V.

1987-01-01T23:59:59.000Z

31

X-ray Emission from Massive Stars  

E-Print Network [OSTI]

X-ray Emission from Massive Stars David Cohen Department of Physics and Astronomy Swarthmore be related to the production of X-rays on massive stars. If so, massive stars' X-rays are much different than those found our own Sun and other cooler stars like the Sun that produce X-rays via magnetic activity

Cohen, David

32

X-ray Emission from Massive Stars  

E-Print Network [OSTI]

X-ray Emission from Massive Stars David Cohen Department of Physics and Astronomy Swarthmore #12;What is the mechanism by which massive stars produce x-rays? New results from the Chandra X-ray Observatory ­ high-resolution x-ray spectroscopy: measuring Doppler broadening in emission lines Testing

Cohen, David

33

Compact x-ray source and panel  

DOE Patents [OSTI]

A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

Sampayon, Stephen E. (Manteca, CA)

2008-02-12T23:59:59.000Z

34

Ultrafast X-ray Absorption Spectroscopy using Laser-Driven Electron X-ray Sources (LEXS)  

E-Print Network [OSTI]

: ultrafast x-rays, x-ray absorption spectroscopy, terawatt lasers, ultrafast reaction dynamics, atomic motion atomic motion by scrutinizing the changes in x- ray absorption spectra during reactions. FirstUltrafast X-ray Absorption Spectroscopy using Laser-Driven Electron X-ray Sources (LEXS) Guangjun

Guo, Ting

35

Focused X-ray source  

DOE Patents [OSTI]

Disclosed is an intense, relatively inexpensive X-ray source (as compared to a synchrotron emitter) for technological, scientific, and spectroscopic purposes. A conical radiation pattern produced by a single foil or stack of foils is focused by optics to increase the intensity of the radiation at a distance from the conical radiator. 8 figs.

Piestrup, M.A.; Boyers, D.G.; Pincus, C.I.; Maccagno, P.

1990-08-21T23:59:59.000Z

36

Microgap x-ray detector  

DOE Patents [OSTI]

An x-ray detector which provides for the conversion of x-ray photons into photoelectrons and subsequent amplification of these photoelectrons through the generation of electron avalanches in a thin gas-filled region subject to a high electric potential. The detector comprises a cathode (photocathode) and an anode separated by the thin, gas-filled region. The cathode may comprise a substrate, such a beryllium, coated with a layer of high atomic number material, such as gold, while the anode can be a single conducting plane of material, such as gold, or a plane of resistive material, such as chromium/silicon monoxide, or multiple areas of conductive or resistive material, mounted on a substrate composed of glass, plastic or ceramic. The charge collected from each electron avalanche by the anode is passed through processing electronics to a point of use, such as an oscilloscope.

Wuest, Craig R. (Danville, CA); Bionta, Richard M. (Livermore, CA); Ables, Elden (Livermore, CA)

1994-01-01T23:59:59.000Z

37

Chest x-Rays | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Chest x-Rays Chest x-Rays Chest x-Rays Chest X-ray B-Reading The B-reading is a special reading of a standard chest x-ray film performed by a physician certified by the National Institute for Occupational Safety and Health (NIOSH). The reading looks for changes on the chest x-ray that may indicate exposure and disease caused by agents such as asbestos or silica. The B-reading is considered a special reading because doctors who are certified by NIOSH to perform B-readings use a specific protocol to read and record the findings as developed by the International Labour Organization (ILO). The ILO's protocol provides rules for systematically examining the x-ray in a step-by-step method and recording certain abnormalities or changes on the chest x-ray that can be attributable to

38

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs...

39

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Imaging in Reflection Print Wednesday, 26 October 2011 00:00 The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities...

40

Producing X-rays at the APS  

ScienceCinema (OSTI)

An introduction and overview of the Advanced Photon Source at Argonne National Laboratory, the technology that produces the brightest X-ray beams in the Western Hemisphere, and the research carried out by scientists using those X-rays.

None

2013-04-19T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

SMB, X-ray Fluorescence Imaging  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fluorescence Imaging X-ray Fluorescence Imaging X-ray fluorescence imaging utilizes the high brightness of SPEAR3 and focused beam generated by the uses of K-B optics, capillaries...

42

Chandra X-ray Observatory Center  

E-Print Network [OSTI]

Chandra X-ray Observatory Center Harvard-Smithsonian Center for Astrophysics 60 Garden St in hot gas about 250 million light years from Earth. (Credit: X-ray: NASA/CXC/SAO/E.Bulbul, et al-Newton has revealed a mysterious X-ray signal in the data. This signal is represented in the circled data

43

X-Ray Absorption Spectroscopy of Metallobiomolecules  

E-Print Network [OSTI]

2/9/07 1 X-Ray Absorption Spectroscopy of Metallobiomolecules The Outskirts of Structural Biology 9, 07] This is a tutorial about the use of X-ray Absorption Spectroscopy (XAS) in biology, RG; Eisenberger, P; Kincaid, BM "X-ray Absorption Spectroscopy of Biological Molecules" Annu. Rev

Scott, Robert A.

44

Chandra X-ray Observatory Center  

E-Print Network [OSTI]

Chandra X-ray Observatory Center Harvard-Smithsonian Center for Astrophysics 60 Garden St million light years from Earth. (Credit: X-ray: NASA/CXC/Wesleyan Univ./R.Kilgard, et al; Optical: NASA with optical data from the Hubble Space Telescope (red, green, and blue). The X-ray data reveal hundreds

45

X-ray Spectroscopy of Cool Stars  

E-Print Network [OSTI]

High-resolution X-ray spectroscopy has addressed not only various topics in coronal physics of stars, but has also uncovered important features relevant for our understanding of stellar evolution and the stellar environment. I summarize recent progress in coronal X-ray spectroscopy and in particular also discuss new results from studies of X-rays from pre-main sequence stars.

M. Guedel

2006-09-11T23:59:59.000Z

46

X-Ray Physics Evan Berkowitz  

E-Print Network [OSTI]

X-Ray Physics Evan Berkowitz Junior, MIT Department of Physics (Dated: October 25, 2006) We measure a variety of phenomena related to X-Ray absorption and production. We present data which conforms within, as are 22 Na electron-positron annhilation lines. The importance of understanding x-rays is demonstrated

47

Chandra X-ray Observatory Center  

E-Print Network [OSTI]

Chandra X-ray Observatory Center Harvard-Smithsonian Center for Astrophysics 60 Garden St 200 million light years from Earth. (Credit: X-ray: NASA/CXC/UAH/M.Sun et al; Optical: NASA, ESA, & the Hubble Heritage Team (STScI/AURA) Caption: This composite image from the Chandra X-ray Observatory (blue

48

X-Ray Absorption Spectroscopy of Metallobiomolecules  

E-Print Network [OSTI]

9/6/09 1 X-Ray Absorption Spectroscopy of Metallobiomolecules The Outskirts of Structural Biology 6, 09] This is a tutorial about the use of X-ray Absorption Spectroscopy (XAS) in biology, RG; Eisenberger, P; Kincaid, BM "X-ray Absorption Spectroscopy of Biological Molecules" Annu. Rev

Scott, Robert A.

49

Chandra X-ray Observatory Center  

E-Print Network [OSTI]

Chandra X-ray Observatory Center Harvard-Smithsonian Center for Astrophysics 60 Garden St. Cambridge, MA 02138 USA http://chandra.harvard.edu Four Supernova Remnants: NASA's Chandra X-ray Observatory's Chandra X-ray Observatory, four newly processed images of supernova remnants dramatically illustrate

50

Using Light to Control How X Rays Interact with Matter  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ultrafast x-ray spectroscopy. ALS femtosecond spectroscopy beamline layout. Femtosecond x-ray and laser pulses derive from a single 800-nm laser oscillator. Femtosecond x rays...

51

X-RAY SPECTROMETRY X-Ray Spectrom. 2007; 36: 336342  

E-Print Network [OSTI]

X-RAY SPECTROMETRY X-Ray Spectrom. 2007; 36: 336­342 Published online in Wiley InterScience (www.interscience.wiley.com) DOI: 10.1002/xrs.980 Fish otolith trace element maps: new approaches with synchrotron microbeam x-ray of elements as they accrete through a fish's life. We apply synchrotron microbeam x-ray fluorescence methods

Limburg, Karin E.

52

X-ray Pulsations in the Supersoft X-ray Binary CAL 83  

E-Print Network [OSTI]

X-ray data reveal that the supersoft X-ray binary CAL 83 exhibits 38.4 minute pulsations at some epochs. These X-ray variations are similar to those found in some novae and are likely to be caused by nonradial pulsations the white dwarf. This is the first detection of pulsations in a classical supersoft X-ray binary.

P. C. Schmidtke; A. P. Cowley

2005-09-28T23:59:59.000Z

53

X-ray Spectroscopy of Cooling Cluster  

SciTech Connect (OSTI)

We review the X-ray spectra of the cores of clusters of galaxies. Recent high resolution X-ray spectroscopic observations have demonstrated a severe deficit of emission at the lowest X-ray temperatures as compared to that expected from simple radiative cooling models. The same observations have provided compelling evidence that the gas in the cores is cooling below half the maximum temperature. We review these results, discuss physical models of cooling clusters, and describe the X-ray instrumentation and analysis techniques used to make these observations. We discuss several viable mechanisms designed to cancel or distort the expected process of X-ray cluster cooling.

Peterson, J.R.; /SLAC; Fabian, A.C.; /Cambridge U., Inst. of Astron.

2006-01-17T23:59:59.000Z

54

X-ray transmissive debris shield  

DOE Patents [OSTI]

An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

Spielman, R.B.

1996-05-21T23:59:59.000Z

55

X-ray Spectroscopy of Cooling Clusters  

E-Print Network [OSTI]

We review the X-ray spectra of the cores of clusters of galaxies. Recent high resolution X-ray spectroscopic observations have demonstrated a severe deficit of emission at the lowest X-ray temperatures as compared to that expected from simple radiative cooling models. The same observations have provided compelling evidence that the gas in the cores is cooling below half the maximum temperature. We review these results, discuss physical models of cooling clusters, and describe the X-ray instrumentation and analysis techniques used to make these observations. We discuss several viable mechanisms designed to cancel or distort the expected process of X-ray cluster cooling.

J. R. Peterson; A. C. Fabian

2005-12-21T23:59:59.000Z

56

X-ray transmissive debris shield  

DOE Patents [OSTI]

An X-ray debris shield for use in X-ray lithography that is comprised of an X-ray window having a layer of low density foam exhibits increased longevity without a substantial increase in exposure time. The low density foam layer serves to absorb the debris emitted from the X-ray source and attenuate the shock to the window so as to reduce the chance of breakage. Because the foam is low density, the X-rays are hardly attenuated by the foam and thus the exposure time is not substantially increased.

Spielman, Rick B. (Albuquerque, NM)

1996-01-01T23:59:59.000Z

57

X-ray lithography using holographic images  

DOE Patents [OSTI]

A non-contact X-ray projection lithography method for producing a desired X-ray image on a selected surface of an X-ray-sensitive material, such as photoresist material on a wafer, the desired X-ray image having image minimum linewidths as small as 0.063 .mu.m, or even smaller. A hologram and its position are determined that will produce the desired image on the selected surface when the hologram is irradiated with X-rays from a suitably monochromatic X-ray source of a selected wavelength .lambda.. On-axis X-ray transmission through, or off-axis X-ray reflection from, a hologram may be used here, with very different requirements for monochromaticity, flux and brightness of the X-ray source. For reasonable penetration of photoresist materials by X-rays produced by the X-ray source, the wavelength X, is preferably chosen to be no more than 13.5 nm in one embodiment and more preferably is chosen in the range 1-5 nm in the other embodiment. A lower limit on linewidth is set by the linewidth of available microstructure writing devices, such as an electron beam.

Howells, Malcolm R. (Berkeley, CA); Jacobsen, Chris (Sound Beach, NY)

1995-01-01T23:59:59.000Z

58

X-ray Observations of Mrk 231  

E-Print Network [OSTI]

This paper presents new X-ray observations of Mrk 231, an active galaxy of particular interest due to its large infrared luminosity and the presence of several blueshifted broad absorption line (BAL) systems, a phenomenon observed in a small fraction of QSOs. A ROSAT HRI image of Mrk 231 is presented, this shows an extended region of soft X-ray emission, covering several tens of kpc, consistent with the extent of the host galaxy. An ASCA observation of Mrk 231 is also presented. Hard X-rays are detected but the data show no significant variability in X-ray flux. The hard X-ray continuum is heavily attenuated and X-ray column estimates range from ~ 2 x 10^{22} - 10^{23} cm^{-2} depending on whether the material is assumed to be neutral or ionized, and on the model assumed for the extended X-ray component. These ASCA data provide only the second hard X-ray spectrum of a BAL AGN presented to date. The broad-band spectral-energy-distribution of the source is discussed. While Mrk 231 is X-ray weak compared to Seyfert 1 galaxies, it has an optical-to-X-ray spectrum typical of a QSO.

T. J. Turner

1998-08-10T23:59:59.000Z

59

Hard x-ray imaging from explorer  

SciTech Connect (OSTI)

Coded aperture X-ray detectors were applied to obtain large increases in sensitivity as well as angular resolution. A hard X-ray coded aperture detector concept is described which enables very high sensitivity studies persistent hard X-ray sources and gamma ray bursts. Coded aperture imaging is employed so that approx. 2 min source locations can be derived within a 3 deg field of view. Gamma bursts were located initially to within approx. 2 deg and X-ray/hard X-ray spectra and timing, as well as precise locations, derived for possible burst afterglow emission. It is suggested that hard X-ray imaging should be conducted from an Explorer mission where long exposure times are possible.

Grindlay, J.E.; Murray, S.S.

1981-11-01T23:59:59.000Z

60

Development of x-ray photoelectron microscope with an x-ray laser source  

Science Journals Connector (OSTI)

We have constructed an x-ray photoelectron microscopic system with an x-ray laser as an x-ray source. The lasing line is the Li-like Al 3d-4f transition at 15.47 nm where the recombining Al plasma is used as the x-ray laser medium. The beam from the x-ray laser cavity was then focused by using a Schwarzschild mirror coated with Mo/Si multilayers. The x-ray beam size with a diameter less than 0.5 ?m and the estimated photon number of about 2×10 6 ? photons/shot into the spot were achieved.

Tadayuki Ohchi; Naohiro Yamaguchi; Chiemi Fujikawa; Tamio Hara; Katsumi Watanabe; Ibuki Tanaka; Masami Taguchi

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Applications of soft x-ray lasers  

SciTech Connect (OSTI)

The high brightness and short pulse duration of soft x-ray lasers provide unique advantages for novel applications. Imaging of biological specimens using x-ray lasers has been demonstrated by several groups. Other applications to fields such as chemistry, material science, plasma diagnostics, and lithography are beginning to emerge. We review the current status of soft x-ray lasers from the perspective of applications, and present an overview of the applications currently being developed.

Skinner, C.H.

1993-08-01T23:59:59.000Z

62

High speed x-ray beam chopper  

DOE Patents [OSTI]

A fast, economical, and compact x-ray beam chopper with a small mass and a small moment of inertia whose rotation can be synchronized and phase locked to an electronic signal from an x-ray source and be monitored by a light beam is disclosed. X-ray bursts shorter than 2.5 microseconds have been produced with a jitter time of less than 3 ns.

McPherson, Armon (Oswego, IL); Mills, Dennis M. (Naperville, IL)

2002-01-01T23:59:59.000Z

63

X-ray laser frequency near-doubling and generation of tunable coherent x rays in plasma  

E-Print Network [OSTI]

X-ray laser frequency near-doubling and generation of tunable coherent x rays in plasma P. L plasmas in which efficient x-ray laser frequency near-doubling is expected for a number of available x-ray of coherent x rays and tunable optical radiation may result in tunable coherent x-ray radiation powerful

Kaplan, Alexander

64

Colloid Coalescence with Focused X Rays  

SciTech Connect (OSTI)

We show direct evidence that focused x rays enable us to merge polymer colloidal particles at room temperature. This phenomenon is ascribed to the photochemical scission of colloids with x rays, reducing the molecular weight, glass transition temperature, surface tension, and viscosity of colloids. The observation of the neck bridge growth with time shows that the x-ray-induced colloid coalescence is analogous to viscoelastic coalescence. This finding suggests a feasible protocol of photonic nanofabrication by sintering or welding of polymers, without thermal damage, using x-ray photonics.

Weon, B. M.; Kim, J. T.; Je, J. H. [X-ray Imaging Center, Department of Materials Science and Engineering, Pohang University of Science and Technology, Pohang, 790-784 (Korea, Republic of); Yi, J. M. [Samsung Advanced Institute of Technology, Yongin, Gyeonggi, 446-712 (Korea, Republic of); Wang, S.; Lee, W.-K. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

2011-07-01T23:59:59.000Z

65

X-RAY MICROBEAM SPEECH PRODUCTION DATABASE  

E-Print Network [OSTI]

X-RAY MICROBEAM SPEECH PRODUCTION DATABASE USER'S HANDBOOK Version 1.0 (June 1994) prepared by John . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Chapter Two: XRMB History

66

X-ray laser microscope apparatus  

DOE Patents [OSTI]

A microscope consisting of an x-ray contact microscope and an optical microscope. The optical, phase contrast, microscope is used to align a target with respect to a source of soft x-rays. The source of soft x-rays preferably comprises an x-ray laser but could comprise a synchrotron or other pulse source of x-rays. Transparent resist material is used to support the target. The optical microscope is located on the opposite side of the transparent resist material from the target and is employed to align the target with respect to the anticipated soft x-ray laser beam. After alignment with the use of the optical microscope, the target is exposed to the soft x-ray laser beam. The x-ray sensitive transparent resist material whose chemical bonds are altered by the x-ray beam passing through the target mater GOVERNMENT LICENSE RIGHTS This invention was made with government support under Contract No. De-FG02-86ER13609 awarded by the Department of Energy. The Government has certain rights in this invention.

Suckewer, Szymon (Princeton, NJ); DiCicco, Darrell S. (Plainsboro, NJ); Hirschberg, Joseph G. (Coral Gables, FL); Meixler, Lewis D. (East Windsor, NJ); Sathre, Robert (Princeton, NJ); Skinner, Charles H. (Lawrenceville, NJ)

1990-01-01T23:59:59.000Z

67

Automation in X-Ray Crystallography  

Science Journals Connector (OSTI)

Automation in X-Ray Crystallography ... But in the past few years, automation procedures have been applied to intrinsically superior experimental methods. ...

S.C. ABRAHAMS

1963-06-03T23:59:59.000Z

68

X-Ray Laser Sources for Microscopy  

Science Journals Connector (OSTI)

Progress and prospects in soft X-ray laser development at Princeton are presented. A comparison to plasma and synchrotron sources is made with a...

C. H. Skinner; D. E. Kim; A. Wouters; D. Voorhees; S. Suckewer

1988-01-01T23:59:59.000Z

69

Compound refractive X-ray lens  

DOE Patents [OSTI]

An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

Nygren, David R. (Berkeley, CA); Cahn, Robert (Walnut Creek, CA); Cederstrom, Bjorn (Traellborg, SE); Danielsson, Mats (Stocksund, SE); Vestlund, Jonas (Stockholm, SE)

2000-01-01T23:59:59.000Z

70

X-Ray Science Division (XSD)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Science Division (XSD) Search Button About Welcome Overview Visiting the APS Mission & Goals Find People Organization Charts Committees Job Openings User Information...

71

X-ray spectroscopy of neutron star low-mass X-ray binaries  

E-Print Network [OSTI]

In this thesis, I present work spanning a variety of topics relating to neutron star lowmass X-ray binaries (LMXBs) and utilize spectral information from X-ray observations to further our understanding of these sources. ...

Krauss, Miriam Ilana

2007-01-01T23:59:59.000Z

72

Ultraluminous X-ray Sources: The most extreme X-ray binaries  

E-Print Network [OSTI]

1 Ultraluminous X-ray Sources: The most extreme X-ray binaries Luca Zampieri INAF ULXs ­ Lubiana ­ May 11, 2012- LZ #12;6 · X-ray observations of nearby galaxies show a population of pointlike, off-nuclear sources with L >> Ledd for 1 Msun (L>1.0e39 erg/s) UltraLuminous X-ray Sources (e

Â?umer, Slobodan

73

X-ray Diffraction (XRD) 1.0 What is X-ray Diffraction  

E-Print Network [OSTI]

X-ray Diffraction (XRD) · 1.0 What is X-ray Diffraction · 2.0 Basics of Crystallography · 3.0 Production of X-rays · 4.0 Applications of XRD · 5.0 Instrumental Sources of Error · 6.0 Conclusions #12 why the cleavage faces of crystals appear to reflect X-ray beams at certain angles of incidence (theta

Moeck, Peter

74

Aneta Siemiginowska Chandra X-ray Center  

E-Print Network [OSTI]

-ray and gamma-ray · High Energy Sky · Chandra X-ray Observatory · examples of typical X-ray data, · an example of a data analysis process · statistical challenges · what do we learn from the data? #12;What is Astronomy and phenomena do we study and how? Solar System: Sun and sollar wind, planets, moons, asteroids, comets Our

Wolfe, Patrick J.

75

Watershed in X-ray Astronomy  

Science Journals Connector (OSTI)

... extent the article on page 96 of this issue of Nature from the X-ray astronomy group at the Massachusetts Institute of Technology is a record of disappointments. That is ... near the galactic centre. Now that the first satellite to be devoted to X-ray astronomy has been launched, and is apparently working successfully, the MIT article and another from ...

1971-01-08T23:59:59.000Z

76

X-Ray Identification of Element 104  

Science Journals Connector (OSTI)

The daughter x-ray identification technique has been applied to the identification of element 104. The characteristic K-series x rays from the ?-decay daughter isotope, nobelium (Z=102), have been observed in coincidence with ? particles from the decay of 4.5-sec 104257, thus providing an unequivocal determination of the parent atomic number, Z=104.

C. E. Bemis; Jr.; R. J. Silva; D. C. Hensley; O. L. Keller; Jr.; J. R. Tarrant; L. D. Hunt; P. F. Dittner; R. L. Hahn; C. D. Goodman

1973-09-03T23:59:59.000Z

77

Comparative Analysis of Urban Atmospheric Aerosol by Particle...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Analysis of Urban Atmospheric Aerosol by Particle-Induced X-ray Emission (PIXE), Proton Elastic Scattering Analysis Comparative Analysis of Urban Atmospheric Aerosol by...

78

Quantitative Measurements of X-ray Intensity  

SciTech Connect (OSTI)

This chapter describes the characterization of several X-ray sources and their use in calibrating different types of X-ray cameras at National Security Technologies, LLC (NSTec). The cameras are employed in experimental plasma studies at Lawrence Livermore National Laboratory (LLNL), including the National Ignition Facility (NIF). The sources provide X-rays in the energy range from several hundred eV to 110 keV. The key to this effort is measuring the X-ray beam intensity accurately and traceable to international standards. This is accomplished using photodiodes of several types that are calibrated using radioactive sources and a synchrotron source using methods and materials that are traceable to the U.S. National Institute of Standards and Technology (NIST). The accreditation procedures are described. The chapter begins with an introduction to the fundamental concepts of X-ray physics. The types of X-ray sources that are used for device calibration are described. The next section describes the photodiode types that are used for measuring X-ray intensity: power measuring photodiodes, energy dispersive photodiodes, and cameras comprising photodiodes as pixel elements. Following their description, the methods used to calibrate the primary detectors, the power measuring photodiodes and the energy dispersive photodiodes, as well as the method used to get traceability to international standards are described. The X-ray source beams can then be measured using the primary detectors. The final section then describes the use of the calibrated X-ray beams to calibrate X-ray cameras. Many of the references are web sites that provide databases, explanations of the data and how it was generated, and data calculations for specific cases. Several general reference books related to the major topics are included. Papers expanding some subjects are cited.

Haugh, M. J., Schneider, M.

2011-09-01T23:59:59.000Z

79

X-ray Practicals Series 1 Advanced Data Reduction  

E-Print Network [OSTI]

X-ray Practicals Series 1 Advanced Data Reduction Instructor J. Reibenspies, Ph. D. Nattamai Bhuvanesh, Ph.D. Version 1.0.0 #12;X-ray Practicals Series 2 #12;X-ray Practicals Series 3 #12;X-ray is good. The y direction is shifting the most, but the shift is ok #12;X-ray Practicals Series 5 Other

Meagher, Mary

80

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lensless X-Ray Imaging in Lensless X-Ray Imaging in Reflection Lensless X-Ray Imaging in Reflection Print Wednesday, 26 October 2011 00:00 The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs combine the advantages of sychrotron light sources (high brightness and x-ray wavelengths relevant to atomic and molecular phenomena) with the advantages of visible-light lasers (highly coherent beams). All of these characteristics are important for coherent x-ray diffraction imaging-lensless imaging techniques that are proving to be integral to single-shot, high-resolution imaging of both complex materials and biological samples. Existing techniques are typically designed for transmission geometry, however, and use isolated objects, requiring special sample fabrication and restricting the type of samples under investigation. Recently, researchers from the ALS and the University of Oregon have shown at ALS Beamline 12.0.2 that it is possible to form x-ray holograms in reflection geometry by using the light scattered from a sample, opening the door to lensless imaging of a wealth of new material samples.

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

X-ray sources in globular clusters  

E-Print Network [OSTI]

The twelve bright (Lx>10(36) erg/s) X-ray sources in the globular clusters have lower luminosities than the brightest sources in the bulge of our galaxy. The dim (Lx<10(35) erg/s) X-ray sources in globular clusters reach higher luminosities than the cataclysmic variables in the disk of our galaxy. The first difference is a statistical fluke, as comparison with M31 indicates. The second difference is explained because the brightest of the dim sources are not cataclysmic variables, but soft X-ray transients in quiescence. This article describes the BeppoSAX, ROSAT and first Chandra observations leading to these conclusions.

Frank Verbunt

2001-11-22T23:59:59.000Z

82

X-RAY EMISSION FROM PLANETS AND COMETS: RELATIONSHIP WITH SOLAR X-RAYS AND SOLAR WIND  

E-Print Network [OSTI]

with the occurrence of solar X-ray flare, when light travel time delay is accounted, suggesting that X-rays fromX-RAY EMISSION FROM PLANETS AND COMETS: RELATIONSHIP WITH SOLAR X-RAYS AND SOLAR WIND ANIL BHARDWAJ Flight center, Greenbelt, MD 20771, USA Scattering of solar X-ray radiation mainly produces the non

Ã?stgaard, Nikolai

83

X-Ray Diffraction The X-Ray Diffraction facility is equipped with state-of-the-art  

E-Print Network [OSTI]

X-Ray Diffraction The X-Ray Diffraction facility is equipped with state-of-the-art diffractometers offering both single crystal and powder X-Ray diffraction. Powder X-Ray Diffraction High resolution data For more details on powder X-Ray analysis contact Dr J Hriljac on 0121 414 4458 or email: j

Birmingham, University of

84

Novel X-Ray Imaging Opportunities for the RPI Linear Accelerator's Tunable, Quasi-monochromatic X-ray Source  

E-Print Network [OSTI]

Novel X-Ray Imaging Opportunities for the RPI Linear Accelerator's Tunable, Quasi-monochromatic X-ray of an intense, tunable, polarized, and quasi-monochromatic X-ray source has been ongoing at Rensselaer Polytechnic Institute since 2001 [1, 2, 3, 4, 5, 6]. This X-ray source, known as Parametric X-rays (PXR

Danon, Yaron

85

X-ray Absorption Spectroscopy of Biologically Relevant Systems  

E-Print Network [OSTI]

308, Messer, B. M. X-ray Absorption Spectroscopy of AqueousSarcosine via X-ray Absorption Spectroscopy 5.1 Introductionwith Carboxylate by X-Ray Absorption Spectroscopy of Liquid

Uejio, Janel Sunayo

2010-01-01T23:59:59.000Z

86

Compact X-Ray Light Source Workshop | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Compact X-Ray Light Source Workshop Compact X-Ray Light Source Workshop Teller R, Terminello L, Thevuthasan T, Moncton D. 2012. "Compact X-Ray Light Source Workshop Report."...

87

Biological Imaging by Soft X-Ray Diffraction Microscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Biological Imaging by Soft X-Ray Diffraction Microscopy Biological Imaging by Soft X-Ray Diffraction Microscopy Print Wednesday, 30 November 2005 00:00 Electron and x-ray...

88

APS Bending Magnet X-rays and  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Irradiation of Nd-Fe-B Permanent Magnets with Irradiation of Nd-Fe-B Permanent Magnets with APS Bending Magnet X-rays and 60 Co γ-rays J. Alderman and P.K. Job APS Operations Division Advanced Photon Source J. Puhl Ionizing Radiation Division National Institute of Standards and Technology June 2000 Table of Contents Introduction Radiation-Induced Demagnetization of Permanent Magnets Resources Required γ-ray Irradiation Results and Analysis of γ-ray Irradiation X-ray Irradiation Results and Analysis of X-ray Irradiation Summary and Conclusions Acknowledgements References Tables and Figures Introduction The Advanced Photon Source (APS), as well as other third-generation synchrotron light sources, uses permanent magnets in the insertion devices to produce x-rays for scientific

89

X-ray source for mammography  

DOE Patents [OSTI]

An x-ray source utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms.

Logan, Clinton M. (Pleasanton, CA)

1994-01-01T23:59:59.000Z

90

Ultrafast X-Ray Sources and Science  

Science Journals Connector (OSTI)

X-ray science is entering the ultrafast and ultraintense era - spurred by developments in coherent, short-wavelength sources that range from tabletop to accelerator-based. These...

Young, Linda

91

X-ray induced optical reflectivity  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

The change in optical reflectivity induced by intense x-ray pulses can now be used to study ultrafast many body responses in solids in the femtosecond time domain. X-ray absorption creates photoelectrons and core level holes subsequently filled by Auger or fluorescence processes, and these excitations ultimately add conduction and valence band carriers that perturb optical reflectivity.Optical absorption associated with band filling and band gap narrowing is shown to explain the basic features found in recent measurements on an insulator (silicon nitride, Si3N4), a semiconductor(gallium arsenide,GaAs), and a metal (gold,Au), obtained with ?100 fs x-ray pulses at 500-2000 eV and probed with 800 nm laser pulses. In particular GaAs exhibits an abrupt drop in reflectivity, persisting only for a time comparable to the x-ray excitation pulse duration, consistent with prompt band gap narrowing.

Durbin, Stephen M.

2012-01-01T23:59:59.000Z

92

SMB, X-ray Emission Spectroscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Emission Spectroscopy Beam Line 6-2b X-ray Emission Spectroscopy Beam Line 6-2b is an advanced spectroscopy experimental station on the multidisciplinary general user wiggler Beam...

93

X-raying galaxies: A Chandra legacy  

Science Journals Connector (OSTI)

...Astronomy, University of Massachusetts, Amherst, MA 01003 This presentation...stellar x-ray sources in the solar neighborhood (8). The...elements—Meteoritic and solar . Geochim Cosmochim Acta 53...Astronomy, University of Massachusetts, Amherst, MA 01003, USA...

Q. Daniel Wang

2010-01-01T23:59:59.000Z

94

Small Angle X-Ray Scattering Detector  

DOE Patents [OSTI]

A detector for time-resolved small-angle x-ray scattering includes a nearly constant diameter, evacuated linear tube having an end plate detector with a first fluorescent screen and concentric rings of first fiber optic bundles for low angle scattering detection and an annular detector having a second fluorescent screen and second fiber optic bundles concentrically disposed about the tube for higher angle scattering detection. With the scattering source, i.e., the specimen under investigation, located outside of the evacuated tube on the tube's longitudinal axis, scattered x-rays are detected by the fiber optic bundles, to each of which is coupled a respective photodetector, to provide a measurement resolution, i.e., dq/q, where q is the momentum transferred from an incident x-ray to an x-ray scattering specimen, of 2% over two (2) orders of magnitude in reciprocal space, i.e., qmax/qmin approx=lO0.

Hessler, Jan P.

2004-06-15T23:59:59.000Z

95

X-Ray Nanoimaging: Instruments and Methods  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Nanoimaging: Instruments and Methods To be held as part of SPIE. http:spie.orgOP318 August 28-29, 2013; San Diego, California, USA...

96

Femtosecond X-ray protein nanocrystallography  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Femtosecond X-ray protein nanocrystallography Authors: Chapman, H.N., Fromme, P., Barty, A., White, T.A., Kirian, R.A., Aquila, A., Hunter, M.S., Schulz, J., DePonte, D.P.,...

97

X-ray source for mammography  

DOE Patents [OSTI]

An x-ray source is described utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms. 6 figures.

Logan, C.M.

1994-12-20T23:59:59.000Z

98

Using X-Ray Computed Tomography in Pore Structure Characterization...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Using X-Ray Computed Tomography in Pore Structure Characterization for a Berea Sandstone: Resolution Effect. Using X-Ray Computed Tomography in Pore Structure Characterization for...

99

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Imaging in Reflection Print X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs combine the advantages of sychrotron light sources (high brightness and x-ray wavelengths relevant to atomic and molecular phenomena) with the advantages of visible-light lasers (highly coherent beams). All of these characteristics are important for coherent x-ray diffraction imaging-lensless imaging techniques that are proving to be integral to single-shot, high-resolution imaging of both complex materials and biological samples. Existing techniques are typically designed for transmission geometry, however, and use isolated objects, requiring special sample fabrication and restricting the type of samples under investigation. Recently, researchers from the ALS and the University of Oregon have shown at ALS Beamline 12.0.2 that it is possible to form x-ray holograms in reflection geometry by using the light scattered from a sample, opening the door to lensless imaging of a wealth of new material samples.

100

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Imaging in Reflection Print X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs combine the advantages of sychrotron light sources (high brightness and x-ray wavelengths relevant to atomic and molecular phenomena) with the advantages of visible-light lasers (highly coherent beams). All of these characteristics are important for coherent x-ray diffraction imaging-lensless imaging techniques that are proving to be integral to single-shot, high-resolution imaging of both complex materials and biological samples. Existing techniques are typically designed for transmission geometry, however, and use isolated objects, requiring special sample fabrication and restricting the type of samples under investigation. Recently, researchers from the ALS and the University of Oregon have shown at ALS Beamline 12.0.2 that it is possible to form x-ray holograms in reflection geometry by using the light scattered from a sample, opening the door to lensless imaging of a wealth of new material samples.

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Argonne CNM: X-Ray Microscopy Capabilities  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Microscopy Facilities X-Ray Microscopy Facilities The Hard X-Ray Nanoprobe (HXN) facility provides scanning fluorescence, scanning diffraction, and full-field transmission and tomographic imaging capabilities with a spatial resolution of 30 nm over a spectral range of 6-12 keV. Modes of Operation Full-Field Transmission Imaging and Nanotomography X-ray transmission imaging uses both the absorption and phase shift of the X-ray beam by the sample as contrast mechanisms. Absorption contrast is used to map the sample density. Elemental constituents can be located by using differential edge contrast in this mode. Phase contrast can be highly sensitive to edges and interfaces even when the X-ray absorption is weak. These contrast mechanisms are exploited to image samples rapidly in full-field transmission mode under various environmental conditions, or combined with nanotomography methods to study the three-dimensional structure of complex and amorphous nanomaterials with the HXN.

102

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lensless X-Ray Imaging in Reflection Print Lensless X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs combine the advantages of sychrotron light sources (high brightness and x-ray wavelengths relevant to atomic and molecular phenomena) with the advantages of visible-light lasers (highly coherent beams). All of these characteristics are important for coherent x-ray diffraction imaging-lensless imaging techniques that are proving to be integral to single-shot, high-resolution imaging of both complex materials and biological samples. Existing techniques are typically designed for transmission geometry, however, and use isolated objects, requiring special sample fabrication and restricting the type of samples under investigation. Recently, researchers from the ALS and the University of Oregon have shown at ALS Beamline 12.0.2 that it is possible to form x-ray holograms in reflection geometry by using the light scattered from a sample, opening the door to lensless imaging of a wealth of new material samples.

103

The Constellation X-ray mission  

Science Journals Connector (OSTI)

The Constellation-X mission is a large collecting area X-ray facility, emphasizing observations at high spectral resolution (E/?E?300–3000) while covering a broad energy band (0.25–40 keV). By increasing the telescope aperture and utilizing efficient spectrometers the mission will achieve a factor of 100 increased sensitivity over current high-resolution X-ray spectroscopy missions. The use of focussing optics across the 10–40 keV band will provide a similar factor of 100 increased sensitivity in this band. Key technologies under development for the mission include lightweight high throughput X-ray optics, multilayer coatings to enhance the hard X-ray performance of X-ray optics, micro-calorimeter spectrometer arrays with 2 eV resolution, low-power and low-weight CCD arrays, lightweight gratings and hard X-ray detectors. When observations commence towards the end of the next decade, Constellation-X will address many pressing questions concerning the extremes of gravity and the evolution of the Universe.

N.E White; H Tananbaum

1999-01-01T23:59:59.000Z

104

X-Ray Observations of Radio Galaxies  

E-Print Network [OSTI]

We review some of the ways that X-ray observations provide unique information on radio galaxies. Thermal bremsstrahlung X-ray emission provides detailed data on ambient densities and temperatures. These parameters in turn can be used for pressure balance calculations and can demonstrate how the ambient gas affects radio source structure. Additionally, many signatures of the interaction of radio jets and lobes with the hot gas are found in high resolution X-ray maps. Non-thermal X-ray emission from knots and hotspots of radio jets can give us constraints on the relativistic electron population for energies greater that that normally sampled in the radio (in the case of synchrotron emission) or can give us an independent estimate of the average magnetic field strength (if inverse Compton emission is the origin of the X-rays). From recent ROSAT HRI observations of 3C 390.3 and 3C 120, we show evidence that X-ray emission from knots and hotspots appears to be associated with regions of large gradients in the radio surface brightness; i.e. at the location of powerful shocks.

D. E. Harris

1998-04-20T23:59:59.000Z

105

Compton backscattered collimated x-ray source  

DOE Patents [OSTI]

A high-intensity, inexpensive and collimated x-ray source is disclosed for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications. 4 figs.

Ruth, R.D.; Huang, Z.

1998-10-20T23:59:59.000Z

106

Compton backscattered collmated X-ray source  

DOE Patents [OSTI]

A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

Ruth, Ronald D. (Woodside, CA); Huang, Zhirong (Stanford, CA)

2000-01-01T23:59:59.000Z

107

Compton backscattered collimated x-ray source  

DOE Patents [OSTI]

A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

Ruth, Ronald D. (Woodside, CA); Huang, Zhirong (Stanford, CA)

1998-01-01T23:59:59.000Z

108

Lensless X-Ray Imaging in Reflection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lensless X-Ray Imaging in Reflection Print Lensless X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs combine the advantages of sychrotron light sources (high brightness and x-ray wavelengths relevant to atomic and molecular phenomena) with the advantages of visible-light lasers (highly coherent beams). All of these characteristics are important for coherent x-ray diffraction imaging-lensless imaging techniques that are proving to be integral to single-shot, high-resolution imaging of both complex materials and biological samples. Existing techniques are typically designed for transmission geometry, however, and use isolated objects, requiring special sample fabrication and restricting the type of samples under investigation. Recently, researchers from the ALS and the University of Oregon have shown at ALS Beamline 12.0.2 that it is possible to form x-ray holograms in reflection geometry by using the light scattered from a sample, opening the door to lensless imaging of a wealth of new material samples.

109

Development of x-ray laminography under an x-ray microscopic condition  

SciTech Connect (OSTI)

An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatial resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique.

Hoshino, Masato; Uesugi, Kentaro; Takeuchi, Akihisa; Suzuki, Yoshio; Yagi, Naoto [Japan Synchrotron Radiation Research Institute JASRI/SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

2011-07-15T23:59:59.000Z

110

X-ray views of neutron star low-mass X-ray binaries  

E-Print Network [OSTI]

A neutron star low-mass X-ray binary is a binary stellar system with a neutron star and a low-mass companion star rotating around each other. In this system the neutron star accretes mass from the companion, and as this matter falls into the deep potential well of the neutron star, the gravitational potential energy is released primarily in the X-ray wavelengths. Such a source was first discovered in X-rays in 1962, and this discovery formally gave birth to the "X-ray astronomy". In the subsequent decades, our knowledge of these sources has increased enormously by the observations with several X-ray space missions. Here we give a brief overview of our current understanding of the X-ray observational aspects of these systems.

Sudip Bhattacharyya

2010-02-24T23:59:59.000Z

111

Is linear response to x-rays suitable for digital dental x-ray imaging systems? —Theoretical and experimental considerations  

Science Journals Connector (OSTI)

The purpose of this study was to consider theoretically and experimentally the suitability of linear response to x-rays for digital dental x-ray imaging systems.

Keiichi Nishikawa PhD; Mamoru Wakoh DDS; PhD; Kinya Kuroyanagi DDS; PhD

2003-06-01T23:59:59.000Z

112

X-ray Pinhole Camera Measurements  

SciTech Connect (OSTI)

The development of the rod pinch diode [1] has led to high-resolution radiography for dynamic events such as explosive tests. Rod pinch diodes use a small diameter anode rod, which extends through the aperture of a cathode plate. Electrons borne off the aperture surface can self-insulate and pinch onto the tip of the rod, creating an intense, small x-ray source (Primary Pinch). This source has been utilized as the main diagnostic on numerous experiments that include high-value, single-shot events. In such applications there is an emphasis on machine reliability, x-ray reproducibility, and x-ray quality [2]. In tests with the baseline rod pinch diode, we have observed that an additional pinch (Secondary Pinch) occurs at the interface near the anode rod and the rod holder. This suggests that stray electrons exist that are not associated with the Primary Pinch. In this paper we present measurements on both pinches using an x-ray pinhole camera. The camera is placed downstream of the Primary Pinch at an angle of 60° with respect to the diode centerline. This diagnostic will be employed to diagnose x-ray reproducibility and quality. In addition, we will investigate the performance of hybrid diodes relating to the formation of the Primary and Secondary Pinches.

Nelson, D. S. [NSTec; Berninger, M. J. [NSTec; Flores, P. A. [NSTec; Good, D. E. [NSTec; Henderson, D. J. [NSTec; Hogge, K. W. [NSTec; Huber, S. R. [NSTec; Lutz, S. S. [NSTec; Mitchell, S. E. [NSTec; Howe, R. A. [NSTec; Mitton, C. V. [NSTec; Molina, I. [NSTec; Bozman, D. R. [SNL; Cordova, S. R. [SNL; Mitchell, D. R. [SNL; Oliver, B. V. [SNL; Ormond, E. C. [SNL

2013-07-01T23:59:59.000Z

113

Nonlinear X-ray Compton Scattering  

E-Print Network [OSTI]

X-ray scattering is a weak linear probe of matter. It is primarily sensitive to the position of electrons and their momentum distribution. Elastic X-ray scattering forms the basis of atomic structural determination while inelastic Compton scattering is often used as a spectroscopic probe of both single-particle excitations and collective modes. X-ray free-electron lasers (XFELs) are unique tools for studying matter on its natural time and length scales due to their bright and coherent ultrashort pulses. However, in the focus of an XFEL the assumption of a weak linear probe breaks down, and nonlinear light-matter interactions can become ubiquitous. The field can be sufficiently high that even non-resonant multiphoton interactions at hard X-rays wavelengths become relevant. Here we report the observation of one of the most fundamental nonlinear X-ray-matter interactions, the simultaneous Compton scattering of two identical photons producing a single photon at nearly twice the photon energy. We measure scattered...

Fuchs, Matthias; Chen, Jian; Ghimire, Shambhu; Shwartz, Sharon; Kozina, Michael; Jiang, Mason; Henighan, Thomas; Bray, Crystal; Ndabashimiye, Georges; Bucksbaum, P H; Feng, Yiping; Herrmann, Sven; Carini, Gabriella; Pines, Jack; Hart, Philip; Kenney, Christopher; Guillet, Serge; Boutet, Sebastien; Williams, Garth; Messerschmidt, Marc; Seibert, Marvin; Moeller, Stefan; Hastings, Jerome B; Reis, David A

2015-01-01T23:59:59.000Z

114

X-ray lithography using holographic images  

DOE Patents [OSTI]

Methods for forming X-ray images having 0.25 {micro}m minimum line widths on X-ray sensitive material are presented. A holographic image of a desired circuit pattern is projected onto a wafer or other image-receiving substrate to allow recording of the desired image in photoresist material. In one embodiment, the method uses on-axis transmission and provides a high flux X-ray source having modest monochromaticity and coherence requirements. A layer of light-sensitive photoresist material on a wafer with a selected surface is provided to receive the image(s). The hologram has variable optical thickness and variable associated optical phase angle and amplitude attenuation for transmission of the X-rays. A second embodiment uses off-axis holography. The wafer receives the holographic image by grazing incidence reflection from a hologram printed on a flat metal or other highly reflecting surface or substrate. In this second embodiment, an X-ray beam with a high degree of monochromaticity and spatial coherence is required. 15 figs.

Howells, M.S.; Jacobsen, C.

1997-03-18T23:59:59.000Z

115

Oscillations During Thermonuclear X-ray Bursts  

E-Print Network [OSTI]

High amplitude, nearly coherent X-ray brightness oscillations during thermonuclear X-ray bursts were discovered with the Rossi X-ray Timing Explorer (RXTE) in early 1996. Spectral and timing evidence strongly supports the conclusion that these oscillations are caused by rotational modulation of the burst emission and that they reveal the spin frequency of neutron stars in low mass X-ray binaries, a long sought goal of X-ray astronomy. Studies carried out over the past year have led to the discovery of burst oscillations in four new sources, bringing to ten the number with confirmed burst oscillations. I review the status of our knowledge of these oscillations and indicate how they can be used to probe the physics of neutron stars. For a few burst oscillation sources it has been proposed that the strongest and most ubiquitous frequency is actually the first overtone of the spin frequency and hence that two nearly antipodal hot spots are present on the neutron star. This inference has important implications for both the physics of thermonuclear burning as well as the mass - radius relation for neutron stars, so its confirmation is crucial. I discuss recent attempts to confirm this hypothesis for 4U 1636-53, the source for which a signal at the putative fundamental (290 Hz) has been claimed.

Tod E. Strohmayer

2001-01-12T23:59:59.000Z

116

X-ray lithography using holographic images  

DOE Patents [OSTI]

Methods for forming X-ray images having 0.25 .mu.m minimum line widths on X-ray sensitive material are presented. A holgraphic image of a desired circuit pattern is projected onto a wafer or other image-receiving substrate to allow recording of the desired image in photoresist material. In one embodiment, the method uses on-axis transmission and provides a high flux X-ray source having modest monochromaticity and coherence requirements. A layer of light-sensitive photoresist material on a wafer with a selected surface is provided to receive the image(s). The hologram has variable optical thickness and variable associated optical phase angle and amplitude attenuation for transmission of the X-rays. A second embodiment uses off-axis holography. The wafer receives the holographic image by grazing incidence reflection from a hologram printed on a flat metal or other highly reflecting surface or substrate. In this second embodiment, an X-ray beam with a high degree of monochromaticity and spatial coherence is required.

Howells, Malcolm S. (Berkeley, CA); Jacobsen, Chris (Sound Beach, NY)

1997-01-01T23:59:59.000Z

117

Predicted X-ray backgrounds for the International X-ray Observatory  

E-Print Network [OSTI]

The background that will be observed by IXO's X-ray detectors naturally separates into two components: (1) a Cosmic X-ray Background (CXB), primarily due to unresolved point sources at high energies (E>2 keV), along with ...

Bautz, Marshall W.

118

Reflection soft X-ray microscope and method  

DOE Patents [OSTI]

A reflection soft X-ray microscope is provided by generating soft X-ray beams, condensing the X-ray beams to strike a surface of an object at a predetermined angle, and focusing the X-ray beams reflected from the surface onto a detector, for recording an image of the surface or near surface features of the object under observation.

Suckewer, Szymon (Princeton, NJ); Skinner, Charles H. (Lawrenceville, NJ); Rosser, Roy (Princeton, NJ)

1993-01-01T23:59:59.000Z

119

Differential phase contrast X-ray imaging system and components  

DOE Patents [OSTI]

A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

Stutman, Daniel; Finkenthal, Michael

2014-07-01T23:59:59.000Z

120

X-ray variability in M87  

E-Print Network [OSTI]

We present the evidence for X-ray variability from the core and from knot A in the M87 jet based on data from two observations with the Einstein Observatory High Resolution Imager (HRI) and three observations with the ROSAT HRI. The core intensity showed a 16% increase in 17 months ('79-'80); a 12% increase in the 3 years '92 to '95; and a 17% drop in the last half of 1995. The intensity of knot A appears to have decreased by 16% between 92Jun and 95Dec. Although the core variability is consistent with general expectations for AGN nuclei, the changes in knot A provide constraints on the x-ray emission process and geometry. Thus we predict that the x-ray morphology of knot A will differ significantly from the radio and optical structure.

D. E. Harris; J. A. Biretta; W. Junor

1996-12-05T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Displaced Vertices from X-ray Lines  

E-Print Network [OSTI]

We present a simple model of weak-scale thermal dark matter that gives rise to X-ray lines. Dark matter consists of two nearly degenerate states near the weak scale, which are populated thermally in the early universe via co-annihilation with slightly heavier states that are charged under the Standard Model. The X-ray line arises from the decay of the heavier dark matter component into the lighter one via a radiative dipole transition, at a rate that is slow compared to the age of the universe. The model predicts observable signatures at the LHC in the form of exotic events with missing energy and displaced leptons and jets. As an application, we show how this model can explain the recently observed 3.55 keV X-ray line.

Adam Falkowski; Yonit Hochberg; Joshua T. Ruderman

2014-09-09T23:59:59.000Z

122

X-ray focal spot locating apparatus and method  

DOE Patents [OSTI]

An X-ray beam finder for locating a focal spot of an X-ray tube includes a mass of X-ray opaque material having first and second axially-aligned, parallel-opposed faces connected by a plurality of substantially identical parallel holes perpendicular to the faces and a film holder for holding X-ray sensitive film tightly against one face while the other face is placed in contact with the window of an X-ray head.

Gilbert, Hubert W. (Cedar Crest, NM)

1985-07-30T23:59:59.000Z

123

X-ray Science Division: Groups  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Division: Groups Division: Groups Atomic, Molecular and Optical Physics (AMO) Primary Contact: Stephen Southworth Work focuses on understanding how strong optical and x-ray fields interact with matter, with an emphasis on photonic control of electronic, atomic and molecular motion. Chemical and Materials Science (CMS) Primary Contact: Randy Winans Research Disciplines: Chemistry, Materials Science Detectors (DET) Primary Contact: Antonino Miceli GMCA Structural Biology Facility (MX) Primary Contact: Robert Fischetti Research Disciplines: Biology, Life Sciences Imaging (IMG) Primary Contact: Francesco DeCarlo Research Disciplines: Materials Science, Biology, Physics, Life Sciences Inelastic X-ray & Nuclear Resonant Scattering (IXN) Primary Contact: Thomas Gog Research Disciplines: Condensed Matter Physics, Geophysics, Materials

124

Cosmology with X-ray Cluster Baryons  

SciTech Connect (OSTI)

X-ray cluster measurements interpreted with a universal baryon/gas mass fraction can theoretically serve as a cosmological distance probe. We examine issues of cosmological sensitivity for current (e.g., Chandra X-ray Observatory, XMM-Newton) and next generation (e.g., Con-X, XEUS) observations, along with systematic uncertainties and biases. To give competitive next generation constraints on dark energy, we find that systematics will need to be controlled to better than 1percent and any evolution in f_gas (and other cluster gas properties) must be calibrated so the residual uncertainty is weaker than (1+z)0.03.

Linder, Eric V.

2007-04-10T23:59:59.000Z

125

Phase recovery for x-ray crystallography  

Science Journals Connector (OSTI)

For many years people have believed that in conventional x-ray crystallography one can only record the diffraction intensities but not the phases. In order to obtain the atomic arrangements, one usually has to guess a structure and then fit the intensity data by refining its parameters. Here, we show that the phases are in fact hidden in the intensity data, and can be directly recovered from the peak profiles. This method is demonstrated by the normal two-beam x-ray diffraction of a noncentrosymmetric crystal, and nontrivial phases are recovered from the intensity data alone.

G. Xu, G. E. Zhou, and X. Y. Zhang

1999-04-01T23:59:59.000Z

126

Time-resolved x-ray diagnostics  

SciTech Connect (OSTI)

Techniques for time-resolved x-ray diagnostics will be reviewed with emphasis on systems utilizing x-ray diodes or scintillators. System design concerns for high-bandwidth (> 1 GHz) diagnostics will be emphasized. The limitations of a coaxial cable system and a technique for equalizing to improve bandwidth of such a system will be reviewed. Characteristics of new multi-GHz amplifiers will be presented. An example of a complete operational system on the Los Alamos Helios laser will be presented which has a bandwidth near 3 GHz over 38 m of coax. The system includes the cable, an amplifier, an oscilloscope, and a digital camera readout.

Lyons, P.B.

1981-01-01T23:59:59.000Z

127

Sharper Focusing of Hard X-rays  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sharper Focusing of Hard X-rays FROM: Physics News Update Number 773 #1, April 12, 2006, by Phil Schewe and Ben Stein Note: This text has been slightly modified from the original. Sharper focusing of hard x-rays has been achieved with a device developed at Argonne National Lab. Because of their high energy, x-rays are hard to focus: they can be reflected from a surface but only at a glancing angle (less than a tenth of a degree); they can be refracted but the index of refraction is very close to 1, so that making efficient lenses becomes a problem; and they can be diffracted, but the relatively thick, variable pitch grating required for focusing is tricky to achieve. The Argonne device is of the diffraction type, and it consists of a stack of alternating layers of metal and silicon, made by depositing progressively thicker layers. When the x-rays fall on such a structure, nearly edge-on, what they see is a grating (called a linear zone plate) consisting of a sort of bar-code pattern.

128

Radioactive Thulium for X-Rays  

Science Journals Connector (OSTI)

Radioactive power from thulium makes Argonne x-ray unit a potential for medical and industrial use ... Active component of the instrument is a tiny particle (one-fifth gram) of thulium-170 which has been made radioactive in a heavy water nuclear reactor at Arco, Idaho. ...

1954-05-03T23:59:59.000Z

129

X-ray spectroscopy of manganese clusters  

SciTech Connect (OSTI)

Much of this thesis represents the groundwork necessary in order to probe Mn clusters more productively than with conventional Mn K-edge XAS and is presented in Part 1. Part 2 contains the application of x-ray techniques to Mn metalloproteins and includes a prognosis at the end of each chapter. Individual Mn oxidation states are more readily distinguishable in Mn L-edge spectra. An empirical mixed valence simulation routine for determining the average Mn oxidation state has been developed. The first Mn L-edge spectra of a metalloprotein were measured and interpreted. The energy of Mn K{beta} emission is strongly correlated with average Mn oxidation state. K{beta} results support oxidation states of Mn(III){sub 2}(IV){sub 2} for the S{sub 1} state of Photosystem II chemical chemically reduced preparations contain predominantly Mn(II). A strength and limitation of XAS is that it probes all of the species of a particular element in a sample. It would often be advantageous to selectively probe different forms of the same element. The first demonstration that chemical shifts in x-ray fluorescence energies can be used to obtain oxidation state-selective x-ray absorption spectra is presented. Spin-dependent spectra can also be used to obtain a more simplified picture of local structure. The first spin-polarized extended x-ray absorption fine structure using Mn K{beta} fluorescence detection is shown.

Grush, M.M. [Univ. of California, Davis, CA (United States). Dept. of Applied Science; [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

1996-06-01T23:59:59.000Z

130

Multiple wavelength X-ray monochromators  

DOE Patents [OSTI]

An improved apparatus and method is provided for separating input x-ray radiation containing first and second x-ray wavelengths into spatially separate first and second output radiation which contain the first and second x-ray wavelengths, respectively. The apparatus includes a crystalline diffractor which includes a first set of parallel crystal planes, where each of the planes is spaced a predetermined first distance from one another. The crystalline diffractor also includes a second set of parallel crystal planes inclined at an angle with respect to the first set of crystal planes where each of the planes of the second set of parallel crystal planes is spaced a predetermined second distance from one another. In one embodiment, the crystalline diffractor is comprised of a single crystal. In a second embodiment, the crystalline diffractor is comprised of a stack of two crystals. In a third embodiment, the crystalline diffractor includes a single crystal that is bent for focusing the separate first and second output x-ray radiation wavelengths into separate focal points. 3 figs.

Steinmeyer, P.A.

1992-11-17T23:59:59.000Z

131

Soft x-ray laser microscope  

SciTech Connect (OSTI)

The program consisted of two phases (Phase I and Phase II). The goal of the Phase I (first year program) was to design and construct the Soft X-ray Laser Contact Microscope. Such microscope was constructed and adapted to PPL's 18.2nm soft X-ray Laser (SXL), which in turn was modified and prepared for microscopy experiments. Investigation of the photoresist response to 18.2nm laser radiation and transmissivity of 0.1m thick silicion-nitride (Si[sub 3]N[sub 4]) windows were important initial works. The goal of the first year of Phase II was to construct X-ray contact microscope in combination with existing optical phase microscope, already used by biologists. In the second year of Phase II study of dehydrated Horeseshoe Crab and Hela cancer cells were performed with COXRALM. Also during Phase II, the Imaging X-Ray Laser Microscope (IXRALM) was designed and constructed. This paper describes the development of each of the microscopes and their application for research.

Suckewer, P.I.

1990-10-01T23:59:59.000Z

132

Small Angle X-Ray Scattering Detector  

DOE Patents [OSTI]

A detector for time-resolved small-angle x-ray scattering includes a nearly constant diameter, evacuated linear tube having an end plate detector with a first fluorescent screen and concentric rings of first fiber optic bundles for low angle scattering detection and an annular detector having a second fluorescent screen and second fiber optic bundles concentrically disposed about the tube for higher angle scattering detection. With the scattering source, i.e., the specimen under investigation, located outside of the evacuated tube on the tube's longitudinal axis, scattered x-rays are detected by the fiber optic bundles, to each of which is coupled a respective photodetector, to provide a measurement resolution, i.e., dq/q, where q is the momentum transferred from an incident x-ray to an x-ray scattering specimen, of 2% over two (2) orders of magnitude in reciprocal space, i.e., q.sub.max /q.sub.min.congruent.100.

Hessler, Jan P. (Downers Grove, IL)

2004-06-15T23:59:59.000Z

133

SLAC All Access: X-ray Microscope  

ScienceCinema (OSTI)

SLAC physicists Johanna Nelson and Yijin Liu give a brief overview of the X-ray microscope at the Stanford Synchrotron Radiation Lightsource (SSRL) that is helping improve rechargeable-battery technology by letting researchers peek into the inner workings of batteries as they operate.

Nelson, Johanna; Liu, Yijin

2014-06-13T23:59:59.000Z

134

Synchrotron x-ray fluorescence and extended x-ray absorption fine structure analysis  

SciTech Connect (OSTI)

The advent of dedicated synchrotron radiation sources has led to a significant increase in activity in many areas of science dealing with the interaction of x-rays with matter. Synchrotron radiation provides intense, linearly polarized, naturally collimated, continuously tunable photon beams, which are used to determine not only the elemental composition of a complex, polyatomic, dilute material but also the chemical form of the elements with improved accuracy. Examples of the application of synchrotron radiation include experiments in synchrotron x-ray fluorescence (SXRF) analysis and extended x-ray absorption fine structure (EXAFS) analysis. New synchrotron radiation x-ray microprobes for elemental analysis in the parts per billion range are under construction at several laboratories. 76 references, 24 figures.

Chen, J.R.; Gordon, B.M.; Hanson, A.L.; Jones, K.W.; Kraner, H.W.; Chao, E.C.T.; Minkin, J.A.

1984-01-01T23:59:59.000Z

135

X-ray imaging crystal spectrometer for extended X-ray sources  

DOE Patents [OSTI]

Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokomak fusion experiment to provide spatially and temporally resolved data on plasma parameters using the imaging properties for Bragg angles near 45. For a Bragg angle of 45.degree., the spherical crystal focuses a bundle of near parallel X-rays (the cross section of which is determined by the cross section of the crystal) from the plasma to a point on a detector, with parallel rays inclined to the main plain of diffraction focused to different points on the detector. Thus, it is possible to radially image the plasma X-ray emission in different wavelengths simultaneously with a single crystal.

Bitter, Manfred L. (Princeton, NJ); Fraenkel, Ben (Jerusalem, IL); Gorman, James L. (Bordentown, NJ); Hill, Kenneth W. (Lawrenceville, NJ); Roquemore, A. Lane (Cranbury, NJ); Stodiek, Wolfgang (Princeton, NJ); von Goeler, Schweickhard E. (Princeton, NJ)

2001-01-01T23:59:59.000Z

136

Rise Time Measurement for Ultrafast X-Ray Pulses  

DOE Patents [OSTI]

A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

Celliers, Peter M.; Weber, Franz A.; Moon, Stephen J.

2005-04-05T23:59:59.000Z

137

X-ray microscopy using grazing-incidence reflection optics  

SciTech Connect (OSTI)

The Kirkpatrick-Baez microscopes are described along with their role as the workhorse of the x-ray imaging devices. This role is being extended with the development of a 22X magnification Kirkpatrick-Baez x-ray microscope with multilayer x-ray mirrors. These mirrors can operate at large angles, high x-ray energies, and have a narrow, well defined x-ray energy bandpass. This will make them useful for numerous experiments. However, where a large solid angle is needed, the Woelter microscope will still be necessary and the technology needed to build them will be useful for many other types of x-ray optics.

Price, R.H.

1981-08-06T23:59:59.000Z

138

X-RAY POINT-SOURCE POPULATIONS CONSTITUTING THE GALACTIC RIDGE X-RAY EMISSION  

SciTech Connect (OSTI)

Apparently diffuse X-ray emission has been known to exist along the central quarter of the Galactic Plane since the beginning of X-ray astronomy; this is referred to as the Galactic Ridge X-ray emission (GRXE). Recent deep X-ray observations have shown that numerous X-ray point sources account for a large fraction of the GRXE in the hard band (2-8 keV). However, the nature of these sources is poorly understood. Using the deepest X-ray observations made in the Chandra bulge field, we present the result of a coherent photometric and spectroscopic analysis of individual X-ray point sources for the purpose of constraining their nature and deriving their fractional contributions to the hard-band continuum and Fe K line emission of the GRXE. Based on the X-ray color-color diagram, we divided the point sources into three groups: A (hard), B (soft and broad spectrum), and C (soft and peaked spectrum). The group A sources are further decomposed spectrally into thermal and non-thermal sources with different fractions in different flux ranges. From their X-ray properties, we speculate that the group A non-thermal sources are mostly active galactic nuclei and the thermal sources are mostly white dwarf (WD) binaries such as magnetic and non-magnetic cataclysmic variables (CVs), pre-CVs, and symbiotic stars, whereas the group B and C sources are X-ray active stars in flares and quiescence, respectively. In the log N-log S curve of the 2-8 keV band, the group A non-thermal sources are dominant above Almost-Equal-To 10{sup -14} erg cm{sup -2} s{sup -1}, which is gradually taken over by Galactic sources in the fainter flux ranges. The Fe K{alpha} emission is mostly from the group A thermal (WD binaries) and the group B (X-ray active stars) sources.

Morihana, Kumiko [Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)] [Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Tsujimoto, Masahiro; Ebisawa, Ken [Japan Aerospace Exploration Agency, Institute of Space and Astronautical Science, 3-1-1 Yoshino-dai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan)] [Japan Aerospace Exploration Agency, Institute of Space and Astronautical Science, 3-1-1 Yoshino-dai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan); Yoshida, Tessei, E-mail: morihana@crab.riken.jp [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan)] [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan)

2013-03-20T23:59:59.000Z

139

Beyond hard x-ray photoelectron spectroscopy: Simultaneous combination with x-ray diffraction  

SciTech Connect (OSTI)

Hard x-ray photoelectron spectroscopy (HAXPES) is a powerful and novel emerging technique for the nondestructive determination of electronic properties and chemical composition of bulk, buried interfaces and surfaces. It benefits from the exceptionally large escape depth of high kinetic energy photoelectrons, increasing the information depth up to several tens of nanometers. Complementing HAXPES with an atomic structure sensitive technique (such as x-ray diffraction) opens a new research field with major applications for materials science. At SpLine, the Spanish CRG beamline at the European Synchrotron Radiation Facility, we have developed a novel experimental set-up that combines HAXPES and x-ray diffraction (x-ray reflectivity, surface x-ray diffraction, grazing incidence x-ray diffraction, and reciprocal space maps). Both techniques can be operated simultaneously on the same sample and using the same excitation source. The set-up includes a robust 2S + 3D diffractometer hosting a ultrahigh vacuum chamber equipped with a unique photoelectron spectrometer (few eV < electron kinetic energy < 15 keV), x-ray tube (Mg/Ti), 15 keV electron gun, and auxiliary standard surface facilities (molecular beam epitaxy evaporator, ion gun, low energy electron diffraction, sample heating/cooling system, leak valves, load-lock sample transfer, etc.). This end-station offers the unique possibility of performing simultaneous HAXPES + x-ray diffraction studies. In the present work, we describe the experimental set-up together with two experimental examples that emphasize its outstanding capabilities: (i) nondestructive characterization of the Si/Ge and HfO{sub 2}/SiO{sub 2} interfaces on Ge-based CMOS devices, and (ii) strain study on La{sub 0.7}Ca{sub 0.3}MnO{sub 3} ultrathin films grown on SrTiO{sub 3}(001) substrate.

Rubio-Zuazo, Juan; Castro, German R. [SpLine, Spanish CRG beamline at the European Synchrotron Radiation Facility, B.P. 220, F-38043 Grenoble (France) and ICMM-CSIC Cantoblanco, E-28049 Madrid (Spain)

2013-05-15T23:59:59.000Z

140

X-rays Illuminate Ancient Archimedes Text  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Related Links: Related Links: May 2005 Headlines TIP Article Press Release Walters Art Museum SSRL Home Page SLAC Home Page Stanford Home Page Tuesday, 31 May 2005 X-rays Illuminate Ancient Archimedes Text (contact: Uwe Bergmann, bergmann@slac.stanford.edu) Archimedes Figure Image provided by Will Noel, The Walters Art Museum An early transcription of Archimedes' mathematical theories has been brought to light through the probing of high-intensity x-rays at SSRL's BL6-2. The text contains part of the Method of Mechanical Theorems, one of Archimedes' most important works, which was probably copied out by a scribe in the tenth century. The parchment on which it was written was later scraped down and reused as pages in a twelfth century prayer book, producing a document known as a palimpsest (which comes from the Greek,

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

HIGH BRILLIANCE X-RAY SCATTERING FOR  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BRILLIANCE X-RAY SCATTERING FOR BRILLIANCE X-RAY SCATTERING FOR LIFE SCIENCES (LIX) Group Leader: Lin Yang Proposal Team: O. Bilsel 1 , B. Hsiao 2 , H. Huang 3 , T. Irving 4 , A. Menzel 5 , L. Pollack 6 , C. Riekel 7 , J. Rubert 8 , H. Tsuruta 9 , L. Yang 10 1 University of Massachusetts, 2 Stony Brook University, 3 Rice University, 4 IIT, 5SLS, 6 Cornell University, 7 European Synchrotron Radiation Facility, 8 NEU, 9 Stanford Synchrotron Radiation Lightsource, 10 Brookhaven National Laboratory TECHNIQUES AND CAPABILITIES APPLICATIONS ADDITIONAL INFORMATION * Energy range 2-20keV using undulator source. Simultaneous SAXS/WAXS to cover 0.003-3Å -1 at 12keV with 1 micron spot size * Time-resolved solution scattering with resolution of (1) microseconds to milliseconds using continuous-flow mixing (5µm x 10µm spot size) and (2) milliseconds using stopped-

142

Element 104 identified by characteristic x rays  

Science Journals Connector (OSTI)

A research team at the Oak Ridge National Laboratory has recently announced that they have conclusively identified the 257 isotope of element 104. This new work shows promise of shedding light on the controversy between Albert Ghiorso and Georgi N. Flerov the leaders respectively of the groups at Lawrence Berkeley Laboratory and the Joint Institute for Nuclear Research Dubna. The isotope 104 X 257 decays by alpha emission to 102 No 253 with a half?life of 4.3 seconds. The Oak Ridge group observed the K?series x rays from nobelium in coincidence with the alpha particles from 104 X 257 ; the observation of x?ray spectra has never been reported previously by the Berkeley or Dubna workers according to Curtis E. Bemis Jr spokesman for the group.

Ronald J. Cohn

1973-01-01T23:59:59.000Z

143

X-ray radiography for container inspection  

DOE Patents [OSTI]

Arrangements of X-ray inspection systems are described for inspecting high-z materials in voluminous objects such as containers. Inspection methods may involve generating a radiographic image based on detected attenuation corresponding to a pulsed beams of radiation transmitted through a voluminous object. The pulsed beams of radiation are generated by a high-energy source and transmitted substantially downward along an incident angle, of approximately 1.degree. to 30.degree., to a vertical axis extending through the voluminous object. The generated radiographic image may be analyzed to detect on localized high attenuation representative of high-z materials and to discriminate high-z materials from lower and intermediate-z materials on the basis of the high density and greater attenuation of high-z material for higher energy (3-10 MeV) X-rays, and the compact nature of threatening masses of fissionable materials.

Katz, Jonathan I. (Clayton, MO); Morris, Christopher L. (Los Alamos, NM)

2011-06-07T23:59:59.000Z

144

Sample holder for X-ray diffractometry  

DOE Patents [OSTI]

A sample holder for use with X-ray diffractometers with the capability to rotate the sample, as well as to adjust the position of the sample in the x, y, and z directions. Adjustment in the x direction is accomplished through loosening set screws, moving a platform, and retightening the set screws. Motion translators are used for adjustment in the y and z directions. An electric motor rotates the sample, and receives power from the diffractometer.

Hesch, Victor L. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

145

Columbia University X-Ray Measurements  

E-Print Network [OSTI]

V-720 keV · NaI 2x2x2" detector views an energy range of 1 keV-3 MeV Store signal in the tree. computer configuration. Plasmas were created using multi-frequency ECRH, and we find that most of the plasma energy is stored in the fast electrons. The energy spectrum of the x-ray emission below 740 keV is measured

146

Silicon Absolute X-Ray Detectors  

SciTech Connect (OSTI)

The responsivity of silicon photodiodes having no loss in the entrance window, measured using synchrotron radiation in the 1.75 to 60 keV range, was compared to the responsivity calculated using the silicon thickness measured using near-infrared light. The measured and calculated responsivities agree with an average difference of 1.3%. This enables their use as absolute x-ray detectors.

Seely, John F. [Naval Research Laboratory, Washington, D.C. 20375 (United States); Korde, Raj; Sprunck, Jacob [International Radiation Detectors, Inc., Torrance, CA 90505-5243 (United States); Medjoubi, Kadda; Hustache, Stephanie [Synchrotron SOLEIL, L'Orme des Merisiers, Saint-Aubin, BP 48, 91192 Gif-sur-Yvette CEDEX (France)

2010-06-23T23:59:59.000Z

147

Ultrashort x-ray backlighters and applications  

SciTech Connect (OSTI)

Previously, using ultrashort laser pulses focused onto solid targets, we have experimentally studied a controllable ultrafast broadband radiation source in the extreme ultraviolet for time-resolved dynamical studies in ultrafast science [J. Workman, A. Maksimchuk, X. Llu, U. Ellenberger, J. S. Coe, C.-Y. Chien, and D. Umstadter, ``Control of Bright Picosecond X-Ray Emission from Intense Sub- Picosecond Laser-Plasma Interactions,`` Phys. Rev. Lett. 75, 2324 (1995)]. Once armed with a bright ultrafast broadband continuum x-ray source and appropriate detectors, we used the source as a backlighter to study a remotely produced plasma. The application of the source to a problem relevant to high-density matter completes the triad: creating and controlling, efficiently detecting, and applying the source. This work represented the first use of an ultrafast laser- produced x-ray source as a time-resolving probe in an application relevant to atomic, plasma and high-energy-density matter physics. Using the x-ray source as a backlighter, we adopted a pump-probe geometry to investigate the dynamic changes in electronic structure of a thin metallic film as it is perturbed by an ultrashort laser pulse. Because the laser deposits its energy in a skin depth of about 100 {Angstrom} before expansion occurs, up to gigabar pressure shock waves lasting picosecond in duration have been predicted to form in these novel plasmas. This raises the possibility of studying high- energy-density matter relevant to inertial confinement fusion (ICF) and astrophysics in small-scale laboratory experiments. In the past, time-resolved measurements of K-edge shifts in plasmas driven by nanosecond pulses have been used to infer conditions in highly compressed materials. In this study, we used 100-fs laser pulses to impulsively drive shocks into a sample (an untamped 1000 {Angstrom} aluminum film on 2000 {Angstrom} of parylene-n), measuring L-edge shifts.

Umstadter, D., University of Michigan

1997-08-01T23:59:59.000Z

148

X-ray holography at Lawrence Livermore National Laboratory  

SciTech Connect (OSTI)

The x-ray holography program at the Lawrence Livermore National Laboratory has two principal goals: (1) the development of x-ray diffraction techniques for DNA sequence analysis and (2) the development of x-ray laser holography for structural analysis of intact biological cells and organelles. DNA sequence analysis will be accomplished by applying x-ray diffraction techniques to determine the ensemble average of the sequence of labels along the individual elements of crystalline DNA. X-ray laser holographic imaging will be accomplished by applying three dimensional x-ray holography to elucidate the structure of few hundred angstrom objects such as 300 {Angstrom} chromatin fibers, nuclear pores and nucleic acid replication complexes in living cells. Existing laboratory x-ray lasers will be utilized to produce flash x-ray holograms of the biological structures.

Trebes, J.; Annese, C.; Birdsall, D.; Brase, J.; Gray, J.; Lane, S.; London, R.; Matthews, D.; Peters, D.; Pinkel, D.; Stone, G.; Rapp, D.; Rosen, M.; Weier, U.; Yorkey, T.

1990-10-11T23:59:59.000Z

149

X-Ray Diffraction Microscopy of Magnetic Structures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Diffraction Microscopy of Magnetic Structures Print science brief icon Scientists working at ALS Beamline 12.0.2.2 have demonstrated a new x-ray technique for producing...

150

X-ray diffraction study of zirconia pillared clays  

Science Journals Connector (OSTI)

X-ray powder diffraction (XRPD) and X-ray radial electronic distribution density (RED) of initial and zirconia-pillared interlayered clays (Zr-PILC) were studied. After pillaring, the basal ... under air to 17.7 ...

D.A. Zyuzin; E.M. Moroz; T.G. Kuznetsova…

2004-01-01T23:59:59.000Z

151

Development of a Schwarzschild-type x-ray microscope  

Science Journals Connector (OSTI)

A Schwarzschild-type x-ray microscope has been designed, constructed, and tested. Ni/C multilayers were used as the x-ray mirrors, with a thickness (2d) of 7 nm and 30 layer pairs. The...

Kado, M; Yamashita, K; Ohtani, M; Tanaka, K A; Kodama, R; Kitamoto, S; Yamanaka, T; Nakai, S

1991-01-01T23:59:59.000Z

152

Biological Imaging by Soft X-Ray Diffraction Microscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Biological Imaging by Soft X-Ray Diffraction Microscopy Print Electron and x-ray microscopes are a valuable tool for both the life and materials sciences, but they are limited in...

153

A Record Run for the APS X-ray Source  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2004 | 2003 | 2002 | 2001 2000 Subscribe to APS News rss feed A Record Run for the APS X-ray Source FEBRUARY 23, 2012 Bookmark and Share The APS storage ring. X-ray beams and...

154

Resonant Soft X-Ray Scattering - Combining Structural with Spectroscop...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Resonant Soft X-Ray Scattering - Combining Structural with Spectroscopic Refinement Friday, September 28, 2012 - 10:00am SLAC, Bldg. 137, Room 322 SSRL Presents Kevin Stone X-ray...

155

TENDER ENERGY X-RAY ABSORPTION  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

TENDER ENERGY X-RAY ABSORPTION TENDER ENERGY X-RAY ABSORPTION SPECTROSCOPY (TES) Project Team: S. Bare 1,2 , J. Brandes 3 , T. Buonassisi 4 , J. Chen 5,2 , M. Croft 6 , E. DiMasi 7 , A. Frenkel 8,2 , D. Hesterberg 9 , S. Hulbert 7,2 , S. Khalid 7 , S. Myneni 10 , P. Northrup 7,11 , E.T. Rasbury 11 , B. Ravel 12 , R. Reeder 11 , J. Rodriguez 7,2 , D. Sparks 5,13 , V. Stojanoff 7 , G. Waychunas 14 1 UOP LLC, 2 Synchrotron Catalysis Consortium, 3 Skidaway Inst. of Oceanography, 4 MIT Laboratory for Photovoltaics Research, 5 Univ. of Delaware, 6 Rutgers Univ., 7 Brookhaven National Lab, 8 Yeshiva Univ., 9 North Carolina State Univ., 10 Princeton Univ., 11 Stony Brook Univ., 12 NIST, 13 Delaware Environmental Inst., 14 Lawrence Berkeley National Lab TECHNIQUES: High performance and in-situ X-ray absorption spectroscopy and spatially-resolved XAS of

156

The X-ray Telescope of CAST  

E-Print Network [OSTI]

The Cern Axion Solar Telescope (CAST) is in operation and taking data since 2003. The main objective of the CAST experiment is to search for a hypothetical pseudoscalar boson, the axion, which might be produced in the core of the sun. The basic physics process CAST is based on is the time inverted Primakoff effect, by which an axion can be converted into a detectable photon in an external electromagnetic field. The resulting X-ray photons are expected to be thermally distributed between 1 and 7 keV. The most sensitive detector system of CAST is a pn-CCD detector combined with a Wolter I type X-ray mirror system. With the X-ray telescope of CAST a background reduction of more than 2 orders off magnitude is achieved, such that for the first time the axion photon coupling constant g_agg can be probed beyond the best astrophysical constraints g_agg < 1 x 10^-10 GeV^-1.

M. Kuster; H. Bräuninger; S. Cébrian; M. Davenport; C. Elefteriadis; J. Englhauser; H. Fischer; J. Franz; P. Friedrich; R. Hartmann; F. H. Heinsius; D. H. H. Hoffmann; G. Hoffmeister; J. N. Joux; D. Kang; K. Königsmann; R. Kotthaus; T. Papaevangelou; C. Lasseur; A. Lippitsch; G. Lutz; J. Morales; A. Rodríguez; L. Strüder; J. Vogel; K. Zioutas

2007-05-10T23:59:59.000Z

157

Applications of holography to x-ray imaging  

SciTech Connect (OSTI)

In this paper we consider various applications of holographic techniques to the problem of soft x-ray imaging. We give special attention to imaging biological material using x-rays in the wavelength range 24 to 45A. We describe some experiments on formation and reconstruction of x-ray holograms and propose some ways in which holographic techniques might contribute to the difficult problem of fabricating optical elements for use in the soft x-ray region.

Howells, M.; Iarocci, M.; Kenney, J.; Rarback, H.; Rosser, R.; Yun, W.

1985-03-01T23:59:59.000Z

158

Applications of holography to X-ray imaging  

SciTech Connect (OSTI)

In this paper the authors consider various applications of holographic techniques to the problem of soft x-ray imaging. Special attention is given to imaging biological material using x-rays in the wavelength range 24-45A. The authors describe some experiments on formation and reconstruction of x-ray holograms and propose some ways in which holographic techniques might contribute to the difficult problem of fabricating optical elements for use in the soft x-ray region.

Howells, M.; Iarocci, M.; Kenney, J.; Rarback, H.; Rosser, R.; Yun, W.

1985-01-01T23:59:59.000Z

159

X-ray MicroCT Training Presentation  

E-Print Network [OSTI]

X-ray MicroCT Training Presentation T. Fettah Kosar, PhD Center for Nanoscale Systems Harvard) Model: HMXST225 (max. 225 kV) #12;Overview 3 Introduction to X-ray imaging and Computed Tomography (CT) · What are X-rays and how do we generate and image them? · How do we magnify X-ray images and keep them

160

Quantitative x-ray imager (abstract)  

SciTech Connect (OSTI)

We report on development of a quantitative x-ray imager (QXI) for the national Inertial Confinement Fusion Program. Included in this development is a study of photocathode response as a function of photon energy, 2--17.5 keV, which is related to diagnostic development on the National Ignition Facility (NIF). The QXI is defined as being a quantative imager due to the repeated characterization. This instrument is systematically checked out, electronically as well as its photocathode x-ray response, both on a direct current and pulsed x-ray sources, before and after its use on a shot campaign. The QXI is a gated x-ray imager1 used for a variety of experiments conducted in the Inertial Confinement Fusion and Radiation Physics Program. The camera was assembled in Los Alamos and has been under development since 1997 and has now become the workhorse framing camera by the program. The electronics were built by Grant Applied Physics of San Fransisco, CA.2 The QXI has been used at the LANL Trident, LLNL Nova, and University of Rochester Laboratory OMEGA laser facilities. The camera consists of a grated microchannel plate (MCP), a phosphor coated fiberoptic faceplate coupled to film for data readout, along with high speed electronic pulsers to drive the x-ray detector. The QXI has both a two-strip and a four-strip detection head and has the ability to individually bias the gain of each of the strips. The timing of the QXI was done at the Trident short pulse laboratory, using 211 nm light. Single strip jitter was looked at as well and determined to be <25 ps. Flatfielding of the photocathode across the MCP was done with the Trident main laser with 150 J on a gold disk with a 1 ns. Spatial resolution was determined to be <5 {mu}m by using the same laser conditions as before and a backlit 1000 lp/in. grid. The QXI has been used on cylindrical implosion work at the Nova Laser Facility, and on direct-drive cylinder mix and indirect-drive high convergence implosion experiments at OMEGA. Its two-strip module has provided the capability to look at point backlighters, as part of technique development for experiments on the NIF. Its next use will be in March 2000 with its off axis viewer nose at Omega, providing a perpendicular view of Rayleigh--Taylor spike dissipation.

Evans, Scott C.; Archuleta, Tom N.; Oertel, John A.; Walsh, Peter J.

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

X-ray Microscopy and Imaging: 2-BM  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BM BM Introduction The 2-BM beamline offers measurement capabilities for x-ray microtomography, x-ray topography and x-ray microdiffraction. X-ray microtomography and x-ray diffraction instruments are installed on separate optical tables for independent operation with fast switch over time. Optically-coupled high-resolution CCD system is used for microtomography and topography with up to 1 micron spatial resolution. X-ray microdiffraction setup consists of KB microfocussing mirrors (~3 micron minimum spot), four-circle Huber diffractometer, high-precision translation sample stage, two orthogonally-mounted video cameras for viewing sample, fluorescence detector (Si-drift diode) and diffraction detector (a scintillation detector or a CCD). Three different levels of monochromaticity are available. Conventional monochromatic x-rays from a double-bounced Si (111) crystal monochromator (DCM, D E/E=1E-4), wide band-pass monochromatic x-rays from a double multilayer monochromator (DMM, D E/E=1~4E-2) and pink beam. The available x-ray range is from 5 keV to 30 keV. The lower limit is due to the x-ray windows and the upper limit is due to the critical angle of the x-ray mirror. Two different coatings (Cr and Pt) for the x-ray mirror allow either 20 keV or 30 keV energy cutoff.

162

Improvement of YOHKOH Hard X-Ray Imaging  

Science Journals Connector (OSTI)

......Figure la shows the X-ray penetration rate through a single, 0.5 mm...index Fig. 1. (a) X-ray penetration rate through a single tung- sten...the K-escape. (b) X-ray penetration rates averaged over the HXT M2 and......

Jun Sato; Takeo Kosugi; Kazuo Makishima

1999-02-01T23:59:59.000Z

163

Small Angle X-ray Scattering (SAXS) Laboratory Learning Experiences  

E-Print Network [OSTI]

.A. & Svergun D.I. (1987). Structure Analysis by Small-Angle X-Ray and Neutron Scattering. NY: Plenum PressSmall Angle X-ray Scattering (SAXS) Laboratory Learning Experiences o - Use of small angle X-ray scattering instrumentation o - Programs that you will use SAXS (BRUKER AXS) PRIMUS (Konarev, Volkov, Koch

Meagher, Mary

164

X-ray Diffraction Laboratory Department of Chemistry  

E-Print Network [OSTI]

X-ray Diffraction Laboratory Department of Chemistry Texas A & M University College Station, Texas Phone : 979-845-9125 www.chem.tamu.edu/xray xray@tamu.edu X-rayDiffractionLaboratory DepartmentofChemistry 3255TAMU CollegeStation,TX77843-3255 Mission The purpose of our laboratory is to provide X-ray

Meagher, Mary

165

X-ray Diffraction Practicals 1 Graphics Programs  

E-Print Network [OSTI]

X-ray Diffraction Practicals 1 Graphics Programs that will read SHELX or CIF files J. Reibenspies, N. Bhuvanesh ver 1.0.0 #12;X-ray Diffraction Practicals 2 Free software. Gretep : Reads SHELX files shelx files or output thermal ellipsoid plots. http://www.umass.edu/microbio/rasmol/ #12;X-ray

Meagher, Mary

166

X-ray Emission from Massive Stars David Cohen  

E-Print Network [OSTI]

X-ray Emission from Massive Stars David Cohen Department of Physics and Astronomy Swarthmore University, Oct. 13, 2005 astro.swarthmore.edu/~cohen/ #12;Outline 1. What you need to know: a. X-rays from the Sun - magnetic activity, x-ray spectra b. Hot stars c. Radiation-driven winds and the Doppler shift d

Cohen, David

167

X-Ray Photoelectron Spectroscopy XPS Mark Engelhard  

E-Print Network [OSTI]

X-Ray Photoelectron Spectroscopy XPS Mark Engelhard 1 #12;EMSL XPS Instrumentation 2 Physical Electronics Quantera XPS High Energy Resolution Focused X-ray Beam Capability Catalysis reaction and processing chamber with inert atmosphere glove box connected to a PHI Quantera Scanning X-ray Microprobe

168

X-Ray Interactions with Matter from the Center for X-Ray Optics (CXRO)  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The primary interactions of low-energy x-rays within condensed matter, viz. photoabsorption and coherent scattering, are described for photon energies outside the absorption threshold regions by using atomic scattering factors. The atomic scattering factors may be accurately determined from the atomic photoabsorption cross sections using modified Kramers-Kronig dispersion relations. From a synthesis of the currently available experimental data and recent theoretical calculations for photoabsorption, the angle-independent, forward-scattering components of the atomic scattering factors have been thus semiempirically determined and tabulated here for 92 elements and for the region 50-30,000 eV. Atomic scattering factors for all angles of coherent scattering and at the higher photon energies are obtained from these tabulated forward-scattering values by adding a simple angle-dependent form-factor correction. The incoherent scattering contributions that become significant for the light elements at the higher photon energies are similarly determined. The basic x-ray interaction relations that are used in applied x-ray physics are presented here in terms of the atomic scattering factors. The bulk optical constants are also related to the atomic scattering factors. These atomic and optical relations are applied to the detailed calculation of the reflectivity characteristics of a series of practical x-ray mirror, multilayer, and crystal monochromators. Comparisons of the results of this semiempirical,"atom-like", description of x-ray interactions for the low-energy region with those of experiment and ab initio theory are presented.

Henke, B.L.; Gullikson, E.M.; Davis, J.C.

169

Generation of first hard X-ray pulse at Tsinghua Thomson Scattering X-ray Source  

SciTech Connect (OSTI)

Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first hard X-ray pulses (51.7 keV) via head-on collision of an 800 nm laser and 46.7 MeV electron beams. The measured yield is 1.0 Multiplication-Sign 10{sup 6} per pulse with an electron bunch charge of 200 pC and laser pulse energy of 300 mJ. The angular intensity distribution and energy spectra of the X-ray pulse are measured with an electron-multiplying charge-coupled device using a CsI scintillator and silicon attenuators. These measurements agree well with theoretical and simulation predictions. An imaging test using the X-ray pulse at the TTX is also presented.

Du Yingchao; Yan Lixin; Hua Jianfei; Du Qiang; Zhang Zhen; Li Renkai; Qian Houjun; Huang Wenhui; Chen Huaibi; Tang Chuanxiang [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Key Laboratory of High Energy Radiation Imaging Fundamental Science for National Defense, Tsinghua University, Beijing 100084 (China)

2013-05-15T23:59:59.000Z

170

Calibrating X-ray Imaging Devices for Accurate Intensity Measurement  

SciTech Connect (OSTI)

The purpose of the project presented is to develop methods to accurately calibrate X-ray imaging devices. The approach was to develop X-ray source systems suitable for this endeavor and to develop methods to calibrate solid state detectors to measure source intensity. NSTec X-ray sources used for the absolute calibration of cameras are described, as well as the method of calibrating the source by calibrating the detectors. The work resulted in calibration measurements for several types of X-ray cameras. X-ray camera calibration measured efficiency and efficiency variation over the CCD. Camera types calibrated include: CCD, CID, back thinned (back illuminated), front illuminated.

Haugh, M. J.

2011-07-28T23:59:59.000Z

171

X-Ray Imaging Crystal Spectrometer for Extended X-Ray Sources  

SciTech Connect (OSTI)

Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokamak fusion experiment to provide spatially and temporally resolved data on plasma parameters such as ion temperature, toroidal and poloidal rotation, electron temperature, impurity ion charge-state distributions, and impurity transport. The imaging properties of these spherically or toroidally curved crystals provide both spectrally and spatially resolved X-ray data from the plasma using only one small spherically or toroidally curved crystal, thus eliminating the requirement for a large array of crystal spectrometers and the need to cross-calibrate the various crystals.

Bitter, Manfred L.; Fraekel, Benjamin; Gorman, James L.; Hill, Kenneth W.; Roquemore, Lane A.; Stodiek, Wolfgang; Goeler, Schweickhard von

1999-05-01T23:59:59.000Z

172

X-Ray Source Based on the Parametric X-Rays  

E-Print Network [OSTI]

Prospects of parametric x-rays (PXR) application for the development of a tuneable quasi-monochromatic x-ray source for medical imaging are discussed. Analysis of basic requirements for electron accelerator shows that it must be relatively low-energy and high-current linac. In comparison with known ultra-relativistic cases, at low energies PXR properties will be modified to a great extent by multiple scattering of the electrons. PXR intensity dependence on target thickness and beam energy are calculated taking multiple scattering into account. It is concluded that PXR source based on real medical accelerators is feasible and can provide x-ray flux needful for obtaining high quality medical images.

Alexander Lobko; Olga Lugovskaya

2005-09-02T23:59:59.000Z

173

Apparatus for monitoring X-ray beam alignment  

DOE Patents [OSTI]

A self-contained, hand-held apparatus is provided for minitoring alignment of an X-ray beam in an instrument employing an X-ray source. The apparatus includes a transducer assembly containing a photoresistor for providing a range of electrical signals responsive to a range of X-ray beam intensities from the X-ray beam being aligned. A circuit, powered by a 7.5 VDC power supply and containing an audio frequency pulse generator whose frequency varies with the resistance of the photoresistor, is provided for generating a range of audible sounds. A portion of the audible range corresponds to low X-ray beam intensity. Another portion of the audible range corresponds to high X-ray beam intensity. The transducer assembly may include an a photoresistor, a thin layer of X-ray fluorescent material, and a filter layer transparent to X-rays but opaque to visible light. X-rays from the beam undergoing alignment penetrate the filter layer and excite the layer of fluorescent material. The light emitted from the fluorescent material alters the resistance of the photoresistor which is in the electrical circuit including the audio pulse generator and a speaker. In employing the apparatus, the X-ray beam is aligned to a complete alignment by adjusting the X-ray beam to produce an audible sound of the maximum frequency.

Steinmeyer, Peter A. (Arvada, CO)

1991-10-08T23:59:59.000Z

174

Photon Sciences | Beamlines | HXN: Hard X-ray Nanoprobe  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HXN: Hard X-ray Nanoprobe HXN: Hard X-ray Nanoprobe Poster | Fact Sheet | Preliminary Design Report Scientific Scope The Hard X-ray Nanoprobe beamline and endstation instruments (HXN) will be designed and constructed to explore new frontiers of hard x-ray microscopy applications with the highest achievable spatial resolution. Currently the available spatial resolution for scientific applications, provided by scanning x-ray microscopes in the hard x-ray regime, is limited to ~50nm, which is still insufficient for probing the nanoscale interfacial structures critical in determining properties and functionalities of material and biological systems. The HXN beamline aims to enable x-ray experiments at spatial resolutions ranging from 10 to 30 nm with an ultimate goal of ~1 nm. Beamline Description

175

Introduction to Neutron and X-Ray Scattering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Scattering Studies of Thin Scattering Studies of Thin Polymer Films Introduction to Neutron and X-Ray Scattering Sunil K. Sinha UCSD/LANL Acknowledgements: Prof. R.Pynn( Indiana U.) Prof. M.Tolan (U. Dortmund) Wilhelm Conrad Röntgen 1845-1923 1895: Discovery of X-Rays 1901 W. C. Röntgen in Physics for the discovery of x-rays. 1914 M. von Laue in Physics for x-ray diffraction from crystals. 1915 W. H. Bragg and W. L. Bragg in Physics for crystal structure determination. 1917 C. G. Barkla in Physics for characteristic radiation of elements. 1924 K. M. G. Siegbahn in Physics for x-ray spectroscopy. 1927 A. H. Compton in Physics for scattering of x-rays by electrons. 1936 P. Debye in Chemistry for diffraction of x-rays and electrons in gases.

176

Hard X-ray tails and cyclotron features in X-ray pulsars  

E-Print Network [OSTI]

We review the physical processes occurring in the magnetosphere of accreting X-ray pulsars, with emphasis on those processes that give rise to observable effects in their high (E>10 keV) energy spectra. In the second part we compare the empirical spectral laws used to fit the observed spectra with theoretical models, at the light of the BeppoSAX results on the broad-band characterization of the X-ray pulsar continuum, and the discovery of new (multiple) cyclotron resonance features.

Mauro Orlandini; Daniele Dal Fiume

2001-07-27T23:59:59.000Z

177

The constellation X-ray mission  

Science Journals Connector (OSTI)

The Constellation-X mission is a large collecting area X-ray facility emphasizing observations at high spectral resolution (E/?E?300–3000) while covering a broad energy band (0.25–40 keV). This mission will achieve a factor of 100 increased sensitivity over current capabilities and is optimized to observe the effects of extreme gravity close to black holes and test models for the formation of large scale structure in the Universe. It is apart of NASA’s strategic plan for launch towards the end of the first decade of the 21st century.

N. E. White; H. Tananbaum

2001-01-01T23:59:59.000Z

178

13 - X-ray and Neutron Scattering  

Science Journals Connector (OSTI)

Abstract This chapter describes the use of neutrons and X-rays as probes in the study of structural and dynamic properties of metallic materials. Crystalline materials are characterized by their diffraction peaks related to their average crystallographic structure. In real crystals, locally displaced atoms and chemically (or isotopically for neutrons) different species may lead not only to changes of peak shapes and positions, but also to additional (diffuse) scattering between Bragg peak, including scattering around the primary beam (small-angle scattering). All these features can be used to extract information about the state of a sample, its compositional and structural variations on a scale depending on the scattering, in static and time-resolved kinetic studies. Energy-resolved scattering also offers an insight into solid-state dynamics on a microscopic scale. Some of the most important methods will be described and illustrated by instructive examples. The presentation offers a combined view of neutron and X-ray scattering, with the necessary simplifications dictated by space limitations. The special properties of thermal neutrons and of hard X-rays (now widely available at synchrotron radiation sources), their mutual combination, and combinations with other methods, in particular electron microscopy, offer ample opportunity to better understand and control materials properties. After a brief introduction to scattering from real crystals and some general ideas about long-range strains and Bragg peaks, the vicinity of Bragg peaks (displacement scattering at large scattering angles), the scattering far away from Bragg peaks (chemical heterogeneities, short-range order), and, in greater detail, small-angle scattering (which is not sensitive to the extent of crystallinity, but to nanoscale variations of chemical composition and of magnetization, precipitation) will be described, along with classical and more recent applications related to short-range ordering and precipitation in bulk and nanostructured alloys. Some other fields are only briefly addressed (grazing-incidence studies of surfaces, radiography, absorption spectroscopies, coherent X-rays). The final section offers some information on the influence of defects on lattice dynamics and on (slow) diffusive motion in materials.

Gernot Kostorz

2014-01-01T23:59:59.000Z

179

RYLLA. [X-ray transport code  

SciTech Connect (OSTI)

This paper describes a computer code, RYLLA, which models the deposition of x-rays into thin metal slabs, and transports the resulting photoelectrons, finding the distribution of electrons leaving the slab from both the front and back surfaces. The slab must be homogeneous, but can contain a mixture of up to 5 different elements. Due to the short electron mean free path at low electron energies, RYLLA should be used only for studying thin slabs, roughly < 100 mg/cm/sup 2/ for low Z metals, and < 10 mg/cm/sup 2/ for high Z metals. X-ray energies should be in the range of 1 to 150 keV, as they are deposited only via photoionization and Compton scattering processes. Following photoionization, a hole exists in the electron cloud of the absorbing atom. This fills either by Auger or fluoresence, resulting in lower energy holes which are also filled. Fluoresence photons are transported and absorbed in the same manner as the primary photons, except that they are isotropically produced. Once all photons have been transported and absorbed, and all holes have been filled, a space- and energy-dependent electron source spectrum has been obtained. This is used in a discrete ordinate expansion solution of the 1-D transport equation, which gives the output electron spectra at the two slab surfaces. This paper discusses both the physics and coding of RYLLA. Examples of user input are given, as are some comparisons with other codes.

Hyde, R.A.

1983-06-08T23:59:59.000Z

180

X-Ray Diffraction on NIF  

SciTech Connect (OSTI)

The National Ignition Facility (NIF) is currently a 192 beam, 1.6 MJ laser. NIF Ramp-Compression Experiments have already made the relevant exo-planet pressure range from 1 to 50 Mbar accessible. We Proposed to Study Carbon Phases by X-Ray Diffraction on NIF. Just a few years ago, ultra-high pressure phase diagrams for materials were very 'simple'. New experiments and theories point out surprising and decidedly complex behavior at the highest pressures considered. High pressures phases of aluminum are also predicted to be complex. Recent metadynamics survey of carbon proposed a dynamic pathway among multiple phases. We need to develop diagnostics and techniques to explore this new regime of highly compressed matter science. X-Ray Diffraction - Understand the phase diagram/EOS/strength/texture of materials to 10's of Mbar. Strategy and physics goals: (1) Powder diffraction; (2) Begin with diamond; (3) Continue with metals etc.; (4) Explore phase diagrams; (5) Develop liquid diffraction; and (6) Reduce background/improve resolution.

Eggert, J H; Wark, J

2012-02-15T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Development of procedures for refurbishing x-ray optics at the Advanced Light Source  

E-Print Network [OSTI]

Development of procedures for refurbishing x-ray optics atpractical and robust procedures for refurbishing x-ray

Yashchuk, Valeriy V.

2013-01-01T23:59:59.000Z

182

Photon Sciences | Beamlines | IXS: Inelastic X-ray Scattering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

IXS: Inelastic X-ray Scattering IXS: Inelastic X-ray Scattering Poster | Fact Sheet | Preliminary Design Report Scientific Scope Many hot topics related to the high frequency dynamics of condensed matter require both a narrower and steeper resolution function and access to a broader dynamic range than what are currently available. This represents a sort of "no man's land" that falls right in the dynamic gap lying between the high frequency spectroscopies, such as inelastic x-ray scattering (IXS), and the low frequency ones. New IXS spectrometers with improved energy and momentum resolutions would be required to fill this gap. To achieve this goal, a new x-ray optics concept for both the monochromatization and energy analysis of x-rays will be implemented at the NSLS-II Inelastic X-ray Scattering beamline. This solution exploits the

183

X-Ray Fluorescence (XRF) | Open Energy Information  

Open Energy Info (EERE)

X-Ray Fluorescence (XRF) X-Ray Fluorescence (XRF) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: X-Ray Fluorescence (XRF) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Rock Lab Analysis Parent Exploration Technique: Rock Lab Analysis Information Provided by Technique Lithology: Bulk and trace element analysis of rocks, minerals, and sediments. Stratigraphic/Structural: Hydrological: Thermal: Dictionary.png X-Ray Fluorescence (XRF): X-Ray Fluorescence is a lab-based technique used for bulk chemical analysis of rock, mineral, sediment, and fluid samples. The technique depends on the fundamental principles of x-ray interactions with solid materials, similar

184

X-Ray Diffraction Microscopy of Magnetic Structures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Diffraction Microscopy of Magnetic Structures Print X-Ray Diffraction Microscopy of Magnetic Structures Print science brief icon Scientists working at ALS Beamline 12.0.2.2 have demonstrated a new x-ray technique for producing short-exposure nanoscale images of the magnetic structure of materials. The new method combines aspects of coherent x-ray diffraction, which can determine 3-D charge distributions, and resonant magnetic scattering, which is sensitive to magnetic structures. Physicists have used coherent x-ray diffraction to measure the electron density of complicated molecules. The formula used to make these calculations contains terms that relate to the electron spin of magnetic atoms, but these terms are traditionally ignored since coherent x-ray diffraction has not been used to retrieve magnetic information. Using the full formula allows for the determination of not only the electron density, but also the magnetic spin distribution and its orientation.

185

Biological Imaging by Soft X-Ray Diffraction Microscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Biological Imaging by Soft X-Ray Diffraction Microscopy Print Biological Imaging by Soft X-Ray Diffraction Microscopy Print Electron and x-ray microscopes are a valuable tool for both the life and materials sciences, but they are limited in their ability to image with nanometer-scale resolution in three dimensions nonperiodic objects that are several microns in size. To fill this gap, the technique of coherent x-ray diffraction imaging now under development takes advantage of the penetrating power of x rays while simultaneously removing the limitations imposed by lens-based optical systems. Researchers from Stony Brook University, in collaboration with scientists at the ALS and Cornell University, have taken a large step in this direction by using a lensless x-ray diffraction microscope to image a freeze-dried yeast cell to better than 30-nm resolution. Images were made at several angular orientations of the cell.

186

APS 7-BM Beamline: X-Ray Resources  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Useful Websites Useful Websites X-Ray Interactions with Matter from CRXO at LBNL. Intuitive interface for x-ray transmission and reflectivity for a wide range of materials. X-Ray Data Booklet from LBNL. Slightly outdated in places, but many useful tables of edge energies, fluorescence lines, and crystal lattice spacings. NIST XCOM Database. Powerful database of photoelectric absorption, elastic scattering, and Compton scattering cross-sections for a wide range of materials. X-Ray Server. Maintained by Sergey Stepanov at GMCA at the APS, this website has several powerful calculators for simulating x-ray reflection and diffraction. Software X-Ray Oriented Programs (XOP). This program, written by scientists at the ESRF and APS, is widely used in the synchrotron research community.

187

Biological Imaging by Soft X-Ray Diffraction Microscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Biological Imaging by Soft X-Ray Diffraction Microscopy Print Biological Imaging by Soft X-Ray Diffraction Microscopy Print Electron and x-ray microscopes are a valuable tool for both the life and materials sciences, but they are limited in their ability to image with nanometer-scale resolution in three dimensions nonperiodic objects that are several microns in size. To fill this gap, the technique of coherent x-ray diffraction imaging now under development takes advantage of the penetrating power of x rays while simultaneously removing the limitations imposed by lens-based optical systems. Researchers from Stony Brook University, in collaboration with scientists at the ALS and Cornell University, have taken a large step in this direction by using a lensless x-ray diffraction microscope to image a freeze-dried yeast cell to better than 30-nm resolution. Images were made at several angular orientations of the cell.

188

X-Ray Diffraction Microscopy of Magnetic Structures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Diffraction Microscopy of Magnetic Structures Print X-Ray Diffraction Microscopy of Magnetic Structures Print science brief icon Scientists working at ALS Beamline 12.0.2.2 have demonstrated a new x-ray technique for producing short-exposure nanoscale images of the magnetic structure of materials. The new method combines aspects of coherent x-ray diffraction, which can determine 3-D charge distributions, and resonant magnetic scattering, which is sensitive to magnetic structures. Physicists have used coherent x-ray diffraction to measure the electron density of complicated molecules. The formula used to make these calculations contains terms that relate to the electron spin of magnetic atoms, but these terms are traditionally ignored since coherent x-ray diffraction has not been used to retrieve magnetic information. Using the full formula allows for the determination of not only the electron density, but also the magnetic spin distribution and its orientation.

189

Biological Imaging by Soft X-Ray Diffraction Microscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Biological Imaging by Soft X-Ray Diffraction Microscopy Print Biological Imaging by Soft X-Ray Diffraction Microscopy Print Electron and x-ray microscopes are a valuable tool for both the life and materials sciences, but they are limited in their ability to image with nanometer-scale resolution in three dimensions nonperiodic objects that are several microns in size. To fill this gap, the technique of coherent x-ray diffraction imaging now under development takes advantage of the penetrating power of x rays while simultaneously removing the limitations imposed by lens-based optical systems. Researchers from Stony Brook University, in collaboration with scientists at the ALS and Cornell University, have taken a large step in this direction by using a lensless x-ray diffraction microscope to image a freeze-dried yeast cell to better than 30-nm resolution. Images were made at several angular orientations of the cell.

190

Definition: X-Ray Diffraction (XRD) | Open Energy Information  

Open Energy Info (EERE)

X-Ray Diffraction (XRD) X-Ray Diffraction (XRD) Jump to: navigation, search Dictionary.png X-Ray Diffraction (XRD) X-Ray Diffraction (XRD) is a laboratory-based technique commonly used for identification of crystalline materials and analysis of unit cell dimensions. One of two primary types of XRD analysis (X-ray powder diffraction and single-crystal XRD) is commonly applied to samples to obtain specific information about the crystalline material under investigation. X-ray powder diffraction is widely used in geology, environmental science, material science, and engineering to rapidly identify unknown crystalline substances (typically in less than 20 minutes). A pure, finely ground, and homogenized sample is required for determination of the bulk composition. Additional uses include detailed

191

X-Ray Diffraction Microscopy of Magnetic Structures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Diffraction Microscopy of Magnetic Structures Print X-Ray Diffraction Microscopy of Magnetic Structures Print science brief icon Scientists working at ALS Beamline 12.0.2.2 have demonstrated a new x-ray technique for producing short-exposure nanoscale images of the magnetic structure of materials. The new method combines aspects of coherent x-ray diffraction, which can determine 3-D charge distributions, and resonant magnetic scattering, which is sensitive to magnetic structures. Physicists have used coherent x-ray diffraction to measure the electron density of complicated molecules. The formula used to make these calculations contains terms that relate to the electron spin of magnetic atoms, but these terms are traditionally ignored since coherent x-ray diffraction has not been used to retrieve magnetic information. Using the full formula allows for the determination of not only the electron density, but also the magnetic spin distribution and its orientation.

192

X-Ray Diffraction (XRD) | Open Energy Information  

Open Energy Info (EERE)

X-Ray Diffraction (XRD) X-Ray Diffraction (XRD) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: X-Ray Diffraction (XRD) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Rock Lab Analysis Parent Exploration Technique: Rock Lab Analysis Information Provided by Technique Lithology: Rapid and unambiguous identification of unknown minerals.[1] Stratigraphic/Structural: Hydrological: Thermal: Dictionary.png X-Ray Diffraction (XRD): X-Ray Diffraction (XRD) is a laboratory-based technique commonly used for identification of crystalline materials and analysis of unit cell dimensions. One of two primary types of XRD analysis (X-ray powder diffraction and single-crystal XRD) is commonly applied to samples to

193

Density gradient free electron collisionally excited X-ray laser  

DOE Patents [OSTI]

An operational X-ray laser (30) is provided that amplifies 3p-3s transition X-ray radiation along an approximately linear path. The X-ray laser (30) is driven by a high power optical laser. The driving line focused optical laser beam (32) illuminates a free-standing thin foil (34) that may be associated with a substrate (36) for improved structural integrity. This illumination produces a generally cylindrically shaped plasma having an essentially uniform electron density and temperature, that exists over a long period of time, and provides the X-ray laser gain medium. The X-ray laser (30) may be driven by more than one optical laser beam (32, 44). The X-ray laser (30) has been successfully demonstrated to function in a series of experimental tests.

Campbell, Edward M. (Pleasanton, CA); Rosen, Mordecai D. (Berkeley, CA)

1989-01-01T23:59:59.000Z

194

Density gradient free electron collisionally excited x-ray laser  

DOE Patents [OSTI]

An operational x-ray laser is provided that amplifies 3p-3s transition x-ray radiation along an approximately linear path. The x-ray laser is driven by a high power optical laser. The driving line focused optical laser beam illuminates a free-standing thin foil that may be associated with a substrate for improved structural integrity. This illumination produces a generally cylindrically shaped plasma having an essentially uniform electron density and temperature, that exists over a long period of time, and provides the x-ray laser gain medium. The x-ray laser may be driven by more than one optical laser beam. The x-ray laser has been successfully demonstrated to function in a series of experimental tests.

Campbell, E.M.; Rosen, M.D.

1984-11-29T23:59:59.000Z

195

Formation of microbeam using tabletop soft X-ray laser  

Science Journals Connector (OSTI)

An X-ray microprobe with a sub-micron size beam and high intensity can provide X-ray analyses with a remarkable spatial resolution. We have performed focusing of an X-ray laser output into a sub-micron beam for the first time. In our experiment, an X-ray laser of Li-like Al 3d–4f transition at 15.47 nm was delivered from an unstable cavity consisting of a concave mirror and a flat mirror with a square orifice of 100×100 ?m in size. The beam from the orifice was then focused by using a Schwarzschild mirror coated with a Mo/Si multilayer. An X-ray beam size with a diameter of about 0.45 ?m and an estimated photon number of about 2×106 photons per shot was achieved. Such sources could be well suited for the realization of X-ray microprobes.

Tadayuki Ohchi; Naohiro Yamaguchi; Chiemi Fujikawa; Tamio Hara

1999-01-01T23:59:59.000Z

196

Portable X-Ray Diffraction (XRD) | Open Energy Information  

Open Energy Info (EERE)

Portable X-Ray Diffraction (XRD) Portable X-Ray Diffraction (XRD) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Portable X-Ray Diffraction (XRD) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Field Techniques Exploration Sub Group: Data Collection and Mapping Parent Exploration Technique: Data Collection and Mapping Information Provided by Technique Lithology: Rapid and unambiguous identification of unknown minerals.[1] Stratigraphic/Structural: Hydrological: Thermal: Dictionary.png Portable X-Ray Diffraction (XRD): Portable X-Ray Diffraction (XRD) is a field-based technique that can be used for identification of crystalline materials and analysis of unit cell dimensions. Portable XRD analysis is similar to X-ray powder diffraction,

197

Biological Imaging by Soft X-Ray Diffraction Microscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Biological Imaging by Soft X-Ray Diffraction Microscopy Print Biological Imaging by Soft X-Ray Diffraction Microscopy Print Electron and x-ray microscopes are a valuable tool for both the life and materials sciences, but they are limited in their ability to image with nanometer-scale resolution in three dimensions nonperiodic objects that are several microns in size. To fill this gap, the technique of coherent x-ray diffraction imaging now under development takes advantage of the penetrating power of x rays while simultaneously removing the limitations imposed by lens-based optical systems. Researchers from Stony Brook University, in collaboration with scientists at the ALS and Cornell University, have taken a large step in this direction by using a lensless x-ray diffraction microscope to image a freeze-dried yeast cell to better than 30-nm resolution. Images were made at several angular orientations of the cell.

198

X-ray Pinhole Camera Measurements  

SciTech Connect (OSTI)

The rod pinch diode is made up of a cathode plate and a small diameter anode rod that extends through the cathode hole. The anode is charged positively. The rod tip is made of a high-z material which is chosen for its bremsstrahlung efficiency. When the diode is pulsed it produces an intense x-ray source used for pulsed radiography. The baseline or reference diode consists of a 0.75 mm diameter Tungsten (W) tapered anode rod which extends 10 mm through a 9 mm diameter 3 mm thick aluminum (Al) aperture. The majority of the current in the electron beam is created on the edges of the cathode aperture and when properly configured, the electrons will self insulate, travel down the extension of the rod, and pinch onto the tip of the rod. In this presentation, performance of hybrid diodes will be compared with the baseline diode.

Nelson, D. S. [NSTec; Berninger, M. J. [NSTec; Flores, P. A. [NSTec; Good, D. E. [NSTec; Henderson, D. J. [NSTec; Hogge, K. W. [NSTec; Huber, S. R. [NSTec; Lutz, S. S. [NSTec; Mitchell, S. E. [NSTec; Howe, R. A. [NSTec; Mitton, C. V. [NSTec; Molina, I. [NSTec; Bozman, D. R. [SNL; Cordova, S. R. [SNL; Mitchell, D. R. [SNL; Oliver, B. V. [SNL; Ormond, E. C. [SNL

2013-06-20T23:59:59.000Z

199

Gray scale x-ray mask  

DOE Patents [OSTI]

The present invention describes a method for fabricating an embossing tool or an x-ray mask tool, providing microstructures that smoothly vary in height from point-to-point in etched substrates, i.e., structure which can vary in all three dimensions. The process uses a lithographic technique to transfer an image pattern in the surface of a silicon wafer by exposing and developing the resist and then etching the silicon substrate. Importantly, the photoresist is variably exposed so that when developed some of the resist layer remains. The remaining undeveloped resist acts as an etchant barrier to the reactive plasma used to etch the silicon substrate and therefore provides the ability etch structures of variable depths.

Morales, Alfredo M. (Livermore, CA); Gonzales, Marcela (Seattle, WA)

2006-03-07T23:59:59.000Z

200

Nonlinear optics with focused x-ray lasers  

SciTech Connect (OSTI)

We have investigated the possibility of focusing x-ray lasers with the use of multilayered mirrors or zone plates. The results indicate that x-ray intensities as high as 10{sup 14} W/cm{sup 2} can be achieved by focusing saturated Ne-like x-ray lasers. These intensities should be adequate for studying nonlinear optical phenomena. 9 refs., 2 figs.

DaSilva, L.B.; Muendel, M.H.; Falcone, R.W.; Fields, D.J.; Kortright, J.B.; MacGowan, B.J.; Matthews, D.L.; Mrowka, S.; Shimkaveg, G.M.; Trebes, J.E.

1990-12-12T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Process and device for x-ray system quality assurance  

SciTech Connect (OSTI)

This invention relates to medical radiography test systems, and more particularly to a method and apparatus for providing evaluation of a medical or dental x-ray system consisting of x-ray generator, film and processor on a daily basis and to thereby assure the production of useful radiographs from the system with no need to repeat patient exposure because of problems with the x-ray system.

Van Pelt, W.F.; Peterson, R.W.

1982-11-10T23:59:59.000Z

202

The first X-ray diffraction measurements on Mars  

Science Journals Connector (OSTI)

The X-ray diffraction/X-ray fluorescence instrument CheMin on the Curiosity rover is a shoebox-sized device using transmission geometry and an energy-discriminating CCD detector. The instrument has returned the first X-ray diffraction data for soil and drilled samples from Mars outcrops, revealing a suite of primary basaltic minerals, amorphous components and varied hydrous alteration products including phyllosilicates.

Bish, D.

2014-10-21T23:59:59.000Z

203

On X-Ray Waveguiding in Nanochannels: Channeling Formalism  

E-Print Network [OSTI]

The question on X-ray extreme focusing (smallest reachable spot size) brings us to the idea for using the wave features of X-ray propagation in media. As known, wave features are revealed at propagation in ultra-narrow collimators as well as at glancing reflection from smooth flat and/or strongly curved surfaces. All these phenomena can be described within the general formalism of X-ray channeling.

S. B. Dabagov

2006-11-20T23:59:59.000Z

204

THE GEODESIC X-RAY TRANSFORM WITH FOLD CAUSTICS The ...  

E-Print Network [OSTI]

Aug 28, 2012 ... THE GEODESIC X-RAY TRANSFORM WITH FOLD CAUSTICS. PLAMEN STEFANOV AND GUNTHER UHLMANN. ABSTRACT. We give a ...

2012-08-28T23:59:59.000Z

205

Inelastic X-ray and Nuclear Resonant Scattering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

... Search About User Information News & Events Science & Education Beamlines Divisions Argonne Home > Advanced Photon Source > Inelastic X-ray and Nuclear Resonant Scattering...

206

Advances in X-Ray Diagnostics of Diesel Fuel Sprays  

Broader source: Energy.gov [DOE]

Recent advances in high-speed X-ray imaging has shown several distinct behaviors of commercial fuel injectors that cannot be seen with more conventional techniques.

207

New intraoral x-ray fluorographic imaging for dentistry  

SciTech Connect (OSTI)

A new dental x-ray fluorographic unit has been developed. This unit is composed of small intraoral x-ray tube, a compact x-ray image intensifier, and a high-resolution TV system. The purposes for developing this equipment were to (1) directly observe the tooth during endodontic procedures and (2) reduce x-ray exposure to the patient and the dentist. The radiation exposure can be reduced to about 1/600 the exposure used with conventional dental film. In clinical trials, a satisfactory fluorographic dental image for endodontic treatment was obtained with this new device.

Higashi, T.; Osada, T.; Aoyama, W.; Iguchi, M.; Suzuki, S.; Kanno, M.; Moriya, K.; Yoshimura, M.; Tusuda, M.

1983-06-01T23:59:59.000Z

208

Normal incidence x-ray mirror for chemical microanalysis  

DOE Patents [OSTI]

An x-ray mirror for both electron column instruments and micro x-ray fluorescence instruments for making chemical, microanalysis comprises a non-planar mirror having, for example, a spherical reflecting surface for x-rays comprised of a predetermined number of alternating layers of high atomic number material and low atomic number material contiguously formed on a substrate and whose layers have a thickness which is a multiple of the wavelength being reflected. For electron column instruments, the wavelengths of interest lie above 1.5nm, while for x-ray fluorescence instruments, the range of interest is below 0.2nm. 4 figs.

Carr, M.J.; Romig, A.D. Jr.

1987-08-05T23:59:59.000Z

209

Self-terminating diffraction gates femtosecond X-ray nanocrystallograp...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Self-terminating diffraction gates femtosecond X-ray nanocrystallography measurements Authors: Barty, A., Caleman, C., Aquila, A., Timneanu, N., Lomb, L., White, T. A., Andreasson,...

210

High intensity x-ray source using liquid gallium target  

DOE Patents [OSTI]

A high intensity x-ray source that uses a flowing stream of liquid gallium as a target with the electron beam impinging directly on the liquid metal.

Smither, Robert K. (Hinsdale, IL); Knapp, Gordon S. (Cupertino, CA); Westbrook, Edwin M. (Chicago, IL); Forster, George A. (Westmont, IL)

1990-01-01T23:59:59.000Z

211

X-ray Diffuse Scattering Measurements of Nucleation Dynamics...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-ray Diffuse Scattering Measurements of Nucleation Dynamics at Femtosecond Resolution Real-time measurement and control of the non-equilibrium properties of materials represents...

212

XRMS: X-Ray Spectroscopy of Magnetic Solids  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

XRMS: X-Ray Spectroscopy of Magnetic Solids October 22-23, 2011 SLAC National Accelerator Laboratory, Menlo Park, CA More information...

213

X-ray absorption fine structure and magnetization characterization...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

characterization of the metallic Co component in Co-doped ZnO thin films . X-ray absorption fine structure and magnetization characterization of the metallic Co...

214

X-ray laser system, x-ray laser and method  

DOE Patents [OSTI]

Disclosed is an x-ray laser system comprising a laser containing generating means for emitting short wave length radiation, and means external to said laser for energizing said generating means, wherein when the laser is in an operative mode emitting radiation, the radiation has a transverse coherence length to width ratio of from about 0.05 to 1. Also disclosed is a method of adjusting the parameters of the laser to achieve the desired coherence length to laser width ratio.

London, Richard A. (Oakland, CA); Rosen, Mordecai D. (Berkeley, CA); Strauss, Moshe (Omer, IL)

1992-01-01T23:59:59.000Z

215

Constraints on jet X-ray emission in low/hard state X-ray binaries  

E-Print Network [OSTI]

We show that the combination of the similarities between the X-ray properties of low luminosity accreting black holes and accreting neutron stars, combined with the differences in their radio properties argues that the X-rays from these systems are unlikely to be formed in the relativistic jets. Specifically, the spectra of extreme island state neutron stars and low/hard state black holes are known to be indistinguishable, while the power spectra from these systems are known to show only minor differences beyond what would be expected from scaling the characteristic variability frequencies by the mass of the compact object. The spectral and temporal similarities thus imply a common emission mechanism that has only minor deviations from having all key parameters scaling linearly with the mass of the compact object, while we show that this is inconsistent with the observations that the radio powers of neutron stars are typically about 30 times lower than those of black holes at the same X-ray luminosity. We also show that an abrupt luminosity change would be expected when a system makes a spectral state transition from a radiatively inefficient jet dominated accretion flow to a thin disk dominated flow, but that such a change is not seen.

Thomas J. Maccarone

2005-03-31T23:59:59.000Z

216

Isotropic star in low-mass X-ray binaries and X-ray pulsars  

E-Print Network [OSTI]

We present a model for compact stars in the low mass X-ray binaries(LMXBs) and X-ray pulsars using a metric given by John J. Matese and Patrick G. Whitman \\citep{Matese and Whitman1980}. Here the field equations are reduced to a system of two algebraic equations considering the isotropic pressure. Compact star candidates 4U 1820-30(radius=10km) in LMXBs, and Her X-1(radius=7.7km), SAX J 1808.4-3658(SS1)(radius=7.07km) and SAX J 1808.4-3658(SS2)(radius=6.35km) in X-ray pulsars satisfy all the energy conditions, TOV-equation and stability condition. From our model, we have derived mass($M$), central density($\\rho_{0}$), suface density($\\rho_{b}$), central pressure($p_{0}$), surface pressure($p_{b}$) and surface red-shift($Z_{s}$) of the above mentioned stars, which are very much consistant with the observed/reported datas\\citep{N. K. Glendenning1997,Gondek2000}. We have also observe the adiabatic index($\\gamma$>4/3) of the above steller objects.

Mehedi Kalam; Sk. Monowar Hossein; Sajahan Molla

2014-10-01T23:59:59.000Z

217

Femtosecond x-ray absorption spectroscopy with hard x-ray free electron laser  

SciTech Connect (OSTI)

We have developed a method of dispersive x-ray absorption spectroscopy with a hard x-ray free electron laser (XFEL), generated by a self-amplified spontaneous emission (SASE) mechanism. A transmission grating was utilized for splitting SASE-XFEL light, which has a relatively large bandwidth (?E/E ? 5 × 10{sup ?3}), into several branches. Two primary split beams were introduced into a dispersive spectrometer for measuring signal and reference spectra simultaneously. After normalization, we obtained a Zn K-edge absorption spectrum with a photon-energy range of 210 eV, which is in excellent agreement with that measured by a conventional wavelength-scanning method. From the analysis of the difference spectra, the noise ratio was evaluated to be ?3 × 10{sup ?3}, which is sufficiently small to trace minute changes in transient spectra induced by an ultrafast optical laser. This scheme enables us to perform single-shot, high-accuracy x-ray absorption spectroscopy with femtosecond time resolution.

Katayama, Tetsuo; Togashi, Tadashi; Tono, Kensuke; Kameshima, Takashi [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan)] [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Inubushi, Yuichi; Sato, Takahiro; Hatsui, Takaki; Yabashi, Makina [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan)] [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Obara, Yuki; Misawa, Kazuhiko [Department of Applied Physics, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588 (Japan)] [Department of Applied Physics, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588 (Japan); Bhattacharya, Atanu; Kurahashi, Naoya [Department of Chemistry, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwakecho, Sakyo-ku, Kyoto 606-8502 (Japan)] [Department of Chemistry, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwakecho, Sakyo-ku, Kyoto 606-8502 (Japan); Ogi, Yoshihiro [Molecular Reaction Dynamics Research Team, RIKEN Center for Advanced Photonics, 2-1 Hirosawa, Wako 351-0198 (Japan)] [Molecular Reaction Dynamics Research Team, RIKEN Center for Advanced Photonics, 2-1 Hirosawa, Wako 351-0198 (Japan); Suzuki, Toshinori [Department of Chemistry, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwakecho, Sakyo-ku, Kyoto 606-8502 (Japan) [Department of Chemistry, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwakecho, Sakyo-ku, Kyoto 606-8502 (Japan); Molecular Reaction Dynamics Research Team, RIKEN Center for Advanced Photonics, 2-1 Hirosawa, Wako 351-0198 (Japan)

2013-09-23T23:59:59.000Z

218

Burning plasmas with ultrashort soft-x-ray flashing  

SciTech Connect (OSTI)

Fast ignition with narrow-band coherent x-ray pulses has been revisited for cryogenic deuterium-tritium (DT) plasma conditions achieved on the OMEGA Laser System. In contrast to using hard-x-rays (hv = 3-6 keV) proposed in the original x-ray fast-ignition proposal, we find that soft-x-ray sources with hv Almost-Equal-To 500 eV photons can be suitable for igniting the dense DT-plasmas achieved on OMEGA. Two-dimensional radiation-hydrodynamics simulations have identified the break-even conditions for realizing such a 'hybrid' ignition scheme (direct-drive compression with soft-x-ray heating) with 50-{mu}m-offset targets: {approx}10 ps soft-x-ray pulse (hv Almost-Equal-To 500 eV) with a total energy of 500-1000 J to be focused into a 10 {mu}m spot-size. A variety of x-ray pulse parameters have also been investigated for optimization. It is noted that an order of magnitude increase in neutron yield has been predicted even with x-ray energy as low as {approx}50 J. Scaling this idea to a 1 MJ large-scale target, a gain above {approx}30 can be reached with the same soft-x-ray pulse at 1.65 kJ energy. Even though such energetic x-ray sources do not currently exist, we hope that the proposed ignition scheme may stimulate efforts on generating powerful soft-x-ray sources in the near future.

Hu, S. X.; Goncharov, V. N.; Skupsky, S. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States)

2012-07-15T23:59:59.000Z

219

Combined energy dispersive EXAFS and x?ray diffraction  

Science Journals Connector (OSTI)

An in situ experiment to measure both x?ray absorption spectroscopy and x?ray diffraction of aurichalcite is described. The experiment uses position sensitive detectors to enable both data sets to be collected while the sample is slowly decomposed in air and then reduced in hydrogen. ?

A. J. Dent; M. P. Wells; R. C. Farrow; C. A. Ramsdale; G. E. Derbyshire; G. N. Greaves; J. W. Couves; J. M. Thomas

1992-01-01T23:59:59.000Z

220

Fresnel and refractive lenses for X-rays  

Science Journals Connector (OSTI)

We present a Gaussian beam analysis of X-ray refractive and Fresnel lenses. The X-ray refractive lens is featured by an intrinsic soft (Gaussian) aperture due to strong absorption of X-rays by materials. We defined a parameter N0, the critical Fresnel number (CFN), to describe this optical property. The values of N0 for all practical materials are below 1000 for photon energies exceeding 30 eV, still lower for high-Z materials. The maximum effective Fresnel number of a lens is determined by its material to be 2N0 and its maximum enhancement of X-ray intensity is limited to (2?N0)2, independent of its shape. We found that the refractive lens is likely to be useful for manipulating nearly diffraction limited beam in the hard X-ray region and its application is severely restricted by available fabrication capabilities today. X-ray Fresnel lenses, both in cylindrical and linear forms, are proposed as superior focusing elements for hard X-rays. Their high efficiency, up to 100% in optimal construction, will enable us to manipulate beams with multiple lenses and obtain higher performance optics. Their design and fabrication are discussed in reference to those of X-ray Fresnel zone plates and micro Fresnel lenses for optoelectronics.

B.X. Yang

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

X-ray attenuation properties of stainless steel (u)  

SciTech Connect (OSTI)

Stainless steel vessels are used to enclose solid materials for studying x-ray radiolysis that involves gas release from the materials. Commercially available stainless steel components are easily adapted to form a static or a dynamic condition to monitor the gas evolved from the solid materials during and after the x-ray irradiation. Experimental data published on the x-ray attenuation properties of stainless steel, however, are very scarce, especially over a wide range of x-ray energies. The objective of this work was to obtain experimental data that will be used to determine how a poly-energetic x-ray beam is attenuated by the stainless steel container wall. The data will also be used in conjunction with MCNP (Monte Carlos Nuclear Particle) modeling to develop an accurate method for determining energy absorbed in known solid samples contained in stainless steel vessels. In this study, experiments to measure the attenuation properties of stainless steel were performed for a range of bremsstrahlung x-ray beams with a maximum energy ranging from 150 keV to 10 MeV. Bremsstrahlung x-ray beams of these energies are commonly used in radiography of engineering and weapon components. The weapon surveillance community has a great interest in understanding how the x-rays in radiography affect short-term and long-term properties of weapon materials.

Wang, Lily L [Los Alamos National Laboratory; Berry, Phillip C [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

222

Shining Soft X-rays on Magnetic Structures  

Science Journals Connector (OSTI)

...2) demonstrate the power of x-ray magneto-optics in a synchroton study of single crystalline FePd layers, which provides...2) demonstrate the power of x-ray magneto-optics in a synchroton study of single crystalline FePd layers, which provides detailed...

Ulrich Hillebrecht

1999-06-25T23:59:59.000Z

223

Human genome sequencing with direct x-ray holographic imaging  

SciTech Connect (OSTI)

Direct holographic imaging of biological materials is widely applicable to the study of the structure, properties and action of genetic material. This particular application involves the sequencing of the human genome where prospective genomic imaging technology is composed of three subtechnologies, name an x-ray holographic camera, suitable chemistry and enzymology for the preparation of tagged DNA samples, and the illuminator in the form of an x-ray laser. We report appropriate x-ray camera, embodied by the instrument developed by MCR, is available and that suitable chemical and enzymatic procedures exist for the preparation of the necessary tagged DNA strands. Concerning the future development of the x-ray illuminator. We find that a practical small scale x-ray light source is indeed feasible. This outcome requires the use of unconventional physical processes in order to achieve the necessary power-compression in the amplifying medium. The understanding of these new physical mechanisms is developing rapidly. Importantly, although the x-ray source does not currently exist, the understanding of these new physical mechanisms is developing rapidly and the research has established the basic scaling laws that will determine the properties of the x-ray illuminator. When this x-ray source becomes available, an extremely rapid and cost effective instrument for 3-D imaging of biological materials can be applied to a wide range of biological structural assays, including the base-pair sequencing of the human genome and many questions regarding its higher levels of organization.

Rhodes, C.K.

1993-06-08T23:59:59.000Z

224

Twelfth National School on Neutron and X-ray Scattering  

E-Print Network [OSTI]

Twelfth National School on Neutron and X-ray Scattering June 12 � June 26, 2010 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

Pennycook, Steve

225

National School on Neutron and X-ray Scattering  

E-Print Network [OSTI]

National School on Neutron and X-ray Scattering May 30 � June 13, 2009 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

Pennycook, Steve

226

National School on Neutron and X-ray Scattering  

E-Print Network [OSTI]

15th National School on Neutron and X-ray Scattering August 10 - 24, 2013 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major Ridge National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang

227

Fourteenth National School on Neutron and X-ray Scattering  

E-Print Network [OSTI]

Fourteenth National School on Neutron and X-ray Scattering August 12 - 25, 2012 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major Ridge National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang

Pennycook, Steve

228

Thirteenth National School on Neutron and X-ray Scattering  

E-Print Network [OSTI]

Thirteenth National School on Neutron and X-ray Scattering June 11 ­ June 25, 2011 at Argonne of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

229

Neutron and X-ray Scattering Study of Magnetic Manganites  

E-Print Network [OSTI]

Neutron and X-ray Scattering Study of Magnetic Manganites Graeme Eoin Johnstone A Thesis submitted are performed using a variety of neutron scattering and x-ray scattering techniques. The electronic ground for analysing the results of the polarised neutron scattering experiment. There are a large number of people who

Boothroyd, Andrew

230

Sixteenth National School on Neutron and X-ray Scattering  

E-Print Network [OSTI]

Sixteenth National School on Neutron and X-ray Scattering June 14-28, 2014 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major's Neutron Scattering Science Division. Scientific Directors: Suzanne G.E. te Velthuis, Esen Ercan Alp

Pennycook, Steve

231

Tenth National School on Neutron and X-ray Scattering  

E-Print Network [OSTI]

Tenth National School on Neutron and X-ray Scattering September 24 - October 11, 2008 at Argonne of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

Pennycook, Steve

232

X-ray spectra transmitted through Compton-thick absorbers  

E-Print Network [OSTI]

X-ray spectra transmitted through matter which is optically thick to Compton scattering are computed by means of Monte Carlo simulations. Applications to the BeppoSAX data of the Seyfert 2 galaxy in Circinus, and to the spectral modeling of the Cosmic X-ray Background, are discussed.

Giorgio Matt; Fulvio Pompilio; Fabio La Franca

1999-04-24T23:59:59.000Z

233

Laser Copper Plasma X-ray Source Debris Characterization  

E-Print Network [OSTI]

Laser Copper Plasma X-ray Source Debris Characterization A Thesis Presented by David Hurley 3, 2007 Vice President for Research and Dean of Graduate studies #12;Abstract Laser copper plasma for x-ray lithography. Copper debris in the form of vapor, ions, dust, and high-speed particles

Huston, Dryver R.

234

Millisecond oscillations during thermonuclear X-ray bursts  

E-Print Network [OSTI]

I analyze 68 oscillation trains detected in a search of 159 thermonuclear bursts from eight neutron star X-ray binaries observed with the Rossi X-ray Timing Explorer. I use all data that were public as of September 2001. ...

Muno, Michael Patrick, 1975-

2002-01-01T23:59:59.000Z

235

X rays following the alpha decay of Pa231  

Science Journals Connector (OSTI)

More detailed information is presented concerning the L and K x-ray spectra due to internal conversion of the electromagnetic transitions following the ? decay of Pa231. Some of the difficulties discussed in Ref. 1 are clarified by the new results.[RADIOACTIVITY Pa231; measured L and K Ac x-ray components, ?? and ?XL coin Ac227 deduced levels, ICC.

A. G. de Pinho; L. T. Auler; A. G. da Silva

1974-05-01T23:59:59.000Z

236

Probing Spatial, Electronic Structures with X-ray Scattering, Spectroscopic  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Probing Spatial, Electronic Structures with X-ray Scattering, Spectroscopic Probing Spatial, Electronic Structures with X-ray Scattering, Spectroscopic Techniques Wednesday, September 5, 2012 - 10:45am SLAC, Bldg. 137, Room 226 Gang Chen Seminar: Structures at atomic scales are traditionally determined through X-ray crystallography that amplifies scattering intensities by introducing spatial periodicity. For amorphous materials and many macromolecules, such as viruses, proteins and biofilms, it is hard to determine structures due to their incapability to crystallize or change of configuration during crystallization. In this talk, I will present the application of X-ray reflectivity and a newly developed fluctuation X-ray scattering technique to study the structures of lipid membranes and randomly oriented nanoparticles. Three different types of domain registrations occurring with

237

Resonant Soft X-Ray Scattering - Combining Structural with Spectroscopic  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Resonant Soft X-Ray Scattering - Combining Structural with Spectroscopic Resonant Soft X-Ray Scattering - Combining Structural with Spectroscopic Refinement Friday, September 28, 2012 - 10:00am SLAC, Bldg. 137, Room 322 SSRL Presents Kevin Stone X-ray absorption spectroscopy has become an important tool in understanding the electronic structure of materials. Resonant absorption edges in the soft x-ray regime are especially interesting as they allow the study of the lighter elements, such as in organic or organo-metallic substances, as well as important L-edges of the 3d transition metals important in magnetic and oxide systems. Measurements of soft x-ray absorption spectra are inherently surface sensitive, and are plagued by issues such as extinction (in electron yield measurements) or self absorption (in fluorescence yield

238

Incoherent x-ray scattering in single molecule imaging  

E-Print Network [OSTI]

Imaging of the structure of single proteins or other biomolecules with atomic resolution would be enormously beneficial to structural biology. X-ray free-electron lasers generate highly intense and ultrashort x-ray pulses, providing a route towards imaging of single molecules with atomic resolution. The information on molecular structure is encoded in the coherent x-ray scattering signal. In contrast to crystallography there are no Bragg reflections in single molecule imaging, which means the coherent scattering is not enhanced. Consequently, a background signal from incoherent scattering deteriorates the quality of the coherent scattering signal. This background signal cannot be easily eliminated because the spectrum of incoherently scattered photons cannot be resolved by usual scattering detectors. We present an ab initio study of incoherent x-ray scattering from individual carbon atoms, including the electronic radiation damage caused by a highly intense x-ray pulse. We find that the coherent scattering pa...

Slowik, Jan Malte; Dixit, Gopal; Jurek, Zoltan; Santra, Robin

2014-01-01T23:59:59.000Z

239

Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Unexpected Angular Dependence of Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism Print Wednesday, 29 August 2007 00:00 Using spectroscopic information for magnetometry and magnetic microscopy obviously requires detailed theoretical understanding of spectral shape and magnitude of dichroism signals. A research team at ALS Beamline 4.0.2 has now shown unambiguously that, contrary to common belief, spectral shape and magnitude of x-ray magnetic linear dichroism (XMLD) are not only determined by the relative orientation of magnetic moments and x-ray polarization, but their orientation relative to the crystallographic axes must be taken into account for accurate interpretation of XMLD data. Magnetism and X Rays

240

X-ray Emission from Massive StarsX-ray Emission from Massive Stars David CohenDavid Cohen  

E-Print Network [OSTI]

X-ray Emission from Massive StarsX-ray Emission from Massive Stars David CohenDavid Cohen/s)Velocity (km/s) #12;absorption emission emission occulted emission emission UV telescope side side front back #12;absorption emission emission occulted emission emission UV telescope side side front back #12;The

Cohen, David

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory  

SciTech Connect (OSTI)

The International X-Ray Observatory (IXO) is under formulation by NASA, ESA and JAXA for deployment in 2022. IXO emerged over the last 18 months as the NASA Constellation-X and ESA/JAXA X-Ray Evolving Universe Spectrometer (XEUS) missions were combined. The driving performance requirements for the X-Ray Microcalorimeter Spectrometer (XMS) are a spectral resolution of 2.5 eV over the central 2'x2' in the 0.3-7.0 keV band, and 10 eV to the edge of the 5'x5' field of view (FOV). The XMS is now based on a microcalorimeter array of Transition-Edge Sensor (TES) thermometers with Au/Bi absorbers and a SQUID MUX readout. One of the concepts studied as part of the mission formulation has a core 40x40 array corresponding to a 2'x2' FOV with 3'' pixels surrounded by an outer, annular 52x52 array of 6'' pixels that extends the field of view to 5.4'x5.4' with better than 10 eV resolution. There are several options for implementing the readout and cooling system of the XMS under study in the US, Europe and Japan. The ADR system will have from two to five stages depending on the performance of the cryocooler. Mechanical coolers with sufficient cooling power at 4K are available now, and {approx}2K coolers are under development. In this paper we give an overview of the XMS instrument, and some of the tradeoffs to be addressed for this observatory instrument.

Kelley, R. L.; Bandler, S. R.; Kilbourne, C. A.; Porter, F. S.; Shirron, P.; Smith, S. J.; Whitehouse, P. [NASA/Goddard Space Flight Center, Greenbelt, MD (United States); Doriese, W. B.; Irwin, K. [National Institute of Standards and Technology, Boulder, CO (United States); Ezoe, Y.; Ishisaki, Y.; Ohashi, T. [Tokyo Metropolitan University, Hachioji, Tokyo (Japan); Fujimoto, R.; Sato, K. [Faculty of Mathematics and Physics, Kanazawa University, Kanazawa (Japan); Gottardi, L.; Hartog, R. den; Herder, J.-W. den; Hoevers, H.; Korte, P. de; Kuur, J. van der [SRON Netherlands Institute for Space Research, Utrecht (Netherlands)] (and others)

2009-12-16T23:59:59.000Z

242

SOFT X-RAY EMISSIONS FROM PLANETS, MOONS, AND COMETS A. Bhardwaj(1)  

E-Print Network [OSTI]

SOFT X-RAY EMISSIONS FROM PLANETS, MOONS, AND COMETS A. Bhardwaj(1) , G. R. Gladstone(2) , R. F to radiate in the soft x-ray energy ( the generation of soft x-rays from these objects, whereas in the hard x-ray energy range (>10 keV) x-rays mainly

Johnson, Robert E.

243

X-ray-induced phase transformation in congruent and vapor-transport-equilibrated lithium tantalate  

E-Print Network [OSTI]

X-ray-induced phase transformation in congruent and vapor-transport-equilibrated lithium tantalate an effect of a partially reversible x-ray-induced increase of diffuse x-ray scattering in both congruent been attributed to x-ray-induced decay of the ferroelectric phase at room temperature. The x-ray

Byer, Robert L.

244

A Hard X-ray View of Accreting X-ray Binary Pulsars  

E-Print Network [OSTI]

The study of the hard (E>10 keV) energy spectra of X-ray binary pulsars can give a wealth of information on the physical processes that occur close to the neutron star surface. Extreme matter regimes are probed, and precious information on how matter and radiation behave and interact in critical conditions can be obtained. We will give an overview on the most recent results obtained by RXTE and BeppoSAX on this class of objects, in order to pass the baton onto just launched experiments, like INTEGRAL, or soon to be launched, like AGILE and ASTRO-E2.

Mauro Orlandini

2004-02-26T23:59:59.000Z

245

Apparatus for generating x-ray holograms  

DOE Patents [OSTI]

Apparatus for x-ray microholography of living biological materials. A Fourier transform holographic configuration is described as being most suitable for the 3-dimensional recording of the physical characteristics of biological specimens. The use of a spherical scatterer as a reference and a charge-coupled device two-dimensional detector array placed in the forward direction relative to the incident x-radiation for viewing electromagnetic radiation simultaneously scattered from both the specimen and the reference scatterer permits the ready reconstruction of the details of the specimen from the fringe pattern detected by the charge-coupled device. For example, by using a nickel reference scatter at 4.5 nm, sufficient reference illumination is provided over a wide enough angle to allow similar resolution in both transverse and longitudinal directions. Both laser and synchrotron radiation sources are feasible for generating microholographs. Operation in the water window (2.4 to 4.5 nm) should provide maximum contrast for features of the specimen and spatial resolution on the order of the wavelength of x-radiation should be possible in all three dimensions, which is sufficient for the visualization of many biological features. It is anticipated that the present apparatus will find utility in other areas as well where microscopic physical details of a specimen are important. A computational procedure which enables the holographic data collected by the detector to be used to correct for misalignments introduced by inexact knowledge of the relative positions of the spherical reference scatterer and the sample under investigation has been developed. If the correction is performed prior to reconstruction, full compensation can be achieved and a faithfully reconstructed image produced.

Rhodes, Charles K. (Chicago, IL); Boyer, Keith (Los Alamos, NM); Solem, Johndale C. (Los Alamos, NM); Haddad, Waleed S. (Chicago, IL)

1990-01-01T23:59:59.000Z

246

Apparatus for generating x-ray holograms  

DOE Patents [OSTI]

Apparatus for x-ray microholography of living biological materials. A Fourier transform holographic configuration is described as being most suitable for the 3-dimensional recording of the physical characteristics of biological specimens. The use of a spherical scatterer as a reference and a charge-coupled device two-dimensional detector array placed in the forward direction relative to the incident x-radiation for viewing electromagnetic radiation simultaneously scattered from both the specimen and the reference scatterer permits the ready reconstruction of the details of the specimen from the fringe pattern detected by the charge-coupled device. For example, by using a nickel reference scatter at 4.5 nm, sufficient reference illumination is provided over a wide enough angle to allow similar resolution in both transverse and longitudinal directions. Both laser and synchrotron radiation sources are feasible for generating microholographs. Operation in the water window (2.4 to 4.5 nm) should provide maximum contrast for features of the specimen and spatial resolution on the order of the wavelength of x-radiation should be possible in all three dimensions, which is sufficient for the visualization of many biological features. It is anticipated that the present apparatus will find utility in other areas as well where microscopic physical details of a specimen are important. A computational procedure which enables the holographic data collected by the detector to be used to correct for misalignments introduced by inexact knowledge of the relative positions of the spherical reference scatterer and the sample under investigation has been developed. If the correction is performed prior to reconstruction, full compensation can be achieved and a faithfully reconstructed image produced. 7 figs.

Rhodes, C.K.; Boyer, K.; Solem, J.C.; Haddad, W.S.

1990-09-11T23:59:59.000Z

247

Biological Imaging by Soft X-Ray Diffraction Microscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Biological Imaging by Soft X-Ray Biological Imaging by Soft X-Ray Diffraction Microscopy Biological Imaging by Soft X-Ray Diffraction Microscopy Print Wednesday, 30 November 2005 00:00 Electron and x-ray microscopes are a valuable tool for both the life and materials sciences, but they are limited in their ability to image with nanometer-scale resolution in three dimensions nonperiodic objects that are several microns in size. To fill this gap, the technique of coherent x-ray diffraction imaging now under development takes advantage of the penetrating power of x rays while simultaneously removing the limitations imposed by lens-based optical systems. Researchers from Stony Brook University, in collaboration with scientists at the ALS and Cornell University, have taken a large step in this direction by using a lensless x-ray diffraction microscope to image a freeze-dried yeast cell to better than 30-nm resolution. Images were made at several angular orientations of the cell.

248

Femtosecond Time-Delay X-ray Holography  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Time-Delay X-ray Holography Time-Delay X-ray Holography X-ray free-electron lasers (XFELs) will produce photon pulses with a unique and desirable combination of properties. Their short X-ray wavelengths allow penetration into materials and the ability to probe structure at and below the nanometer scale. Their ultra-short duration gives information about this structure at the fundamental time-scales of atoms and molecules. The extreme intensity of the pulses will allow this information to be acquired in a single shot, so that these studies can be carried out on non-repeatable processes or on weakly-scattering objects that will be modified by the pulse. A fourth property of XFEL pulses is their high transverse coherence, which brings the promise of decades of innovation in visible optics to the X-ray regime, such as holography, interferometry, and laser-based imaging. Making an effective use of XFEL pulses, however, will benefit from innovations that are new to both X-ray science and coherent optics. One such innovation is the new method of time-delay X-ray holography [i], recently demonstrated at the FLASH FEL at DESY in Hamburg, to measure the evolution of objects irradiated by intense pulses.

249

X-ray Crystallographic Center (XCC) User Registration Form Peter Y. Zavalij X-ray Crystallographi Center 091 Chemistry Bldg. / College Park, MD 20742  

E-Print Network [OSTI]

X-ray Crystallographic Center (XCC) User Registration Form Peter Y. Zavalij X-ray Crystallographi. or advisor confirmation e-mail X-ray Diffractometer that will be used: User Level and Status Smart Apex2X'Pert Pro MRD (Reflectivity & low angles) Xeuss (Small/Wide Angle X-ray Scattering) Submitting user ­ only

Thirumalai, Devarajan

250

Lunar X-ray fluorescence observations by the Chandrayaan-1 X-ray Spectrometer (C1XS): Results from the nearside southern highlands  

E-Print Network [OSTI]

Lunar X-ray fluorescence observations by the Chandrayaan-1 X-ray Spectrometer (C1XS): Results from Spectroscopy a b s t r a c t The Chandrayaan-1 X-ray Spectrometer (C1XS) flown on-board the first Indian lunar mission Chan- drayaan-1, measured X-ray fluorescence spectra during several episodes of solar flares

Wieczorek, Mark

251

National Ignition Facility core x-ray streak camera  

SciTech Connect (OSTI)

The National Ignition Facility (NIF) core x-ray streak camera will be used for laser performance verification experiments as well as a wide range of physics experiments in the areas of high-energy-density science, inertial confinement fusion, and basic science. The x-ray streak camera system is being designed to record time-dependent x-ray emission from NIF targets using an interchangeable family of snouts for measurements such as one-dimensional (1D) spatial imaging or spectroscopy. the NIF core x-ray streak camera will consist of an x-ray-sensitive photocathode that detects x rays with 1D spatial resolution coupled to an electron streak tube to detect a continuous time history of the x rays incident on the photocathode over selected time periods. A charge-coupled-device (CCD) readout will record the signal from the streak tube. The streak tube, CCD, and associated electronics will reside in an electromagnetic interference, and electromagnetic pulse protected, hermetically sealed, temperature-controlled box whose internal pressure is approximately 1 atm. The streak tube itself will penetrate through the wall of the box into the target chamber vacuum. We are working with a goal of a spatial resolution of 15 lp/mm with 50% contrast transfer function at the photocathode and adjustment sweep intervals of 1--50 ns. The camera spectral sensitivity extends from soft x rays to 20 keV x rays, with varying quantum efficiency based on photocathode selection. The system will have remote control, monitoring, and Ethernet communications through an embedded controller. The core streak camera will be compatible with the instrument manipulators at the OMEGA (University of Rochester) and NIF facilities.

Kimbrough, J. R.; Bell, P. M.; Christianson, G. B.; Lee, F. D.; Kalantar, D. H.; Perry, T. S.; Sewall, N. R.; Wootton, A. J.

2001-01-01T23:59:59.000Z

252

The radiation-tolerant x-ray monitor  

SciTech Connect (OSTI)

A vacuum photoelectric detector (monitor) (VPD) designed for plasma tomography, megnetohydrodynamics monitoring, and imaging with the help of thermal x-ray radiation on the ITER facility is described. Laboratory experiments demonstrate that VPD has high sensitivity to thermal x rays and low sensitivity to hard gamma rays and neutrons. The results of tests of a prototype of this monitor on a {sup 60}Co source of gamma rays, on nuclear reactor and its calibration using radiation from an x-ray tube, and tests of its serviceability on the T-10 facility are presented.

Gott, Yu. V.; Stepanenko, M. M. [Nuclear Fusion Institute, Russian Research Center 'Kurchatov Institute', Kurchatov Sq. 1, Moscow 123182 (Russian Federation)

2008-10-15T23:59:59.000Z

253

X-ray backscatter imaging of nuclear materials  

DOE Patents [OSTI]

The energy of an X-ray beam and critical depth are selected to detect structural discontinuities in a material having an atomic number Z of 57 or greater. The critical depth is selected by adjusting the geometry of a collimator that blocks backscattered radiation so that backscattered X-ray originating from a depth less than the critical depth is not detected. Structures of Lanthanides and Actinides, including nuclear fuel rod materials, can be inspected for structural discontinuities such as gaps, cracks, and chipping employing the backscattered X-ray.

Chapman, Jeffrey Allen; Gunning, John E; Hollenbach, Daniel F; Ott, Larry J; Shedlock, Daniel

2014-09-30T23:59:59.000Z

254

Cryogenic X-Ray Diffraction Microscopy for Biological Samples  

Science Journals Connector (OSTI)

X-ray diffraction microscopy (XDM) is well suited for nondestructive, high-resolution biological imaging, especially for thick samples, with the high penetration power of x rays and without limitations imposed by a lens. We developed nonvacuum, cryogenic (cryo-) XDM with hard x rays at 8 keV and report the first frozen-hydrated imaging by XDM. By preserving samples in amorphous ice, the risk of artifacts associated with dehydration or chemical fixation is avoided, ensuring the imaging condition closest to their natural state. The reconstruction shows internal structures of intact D. radiodurans bacteria in their natural contrast.

Enju Lima; Lutz Wiegart; Petra Pernot; Malcolm Howells; Joanna Timmins; Federico Zontone; Anders Madsen

2009-11-05T23:59:59.000Z

255

Cryogenic X-ray Diffraction Microscopy for Biological Samples  

SciTech Connect (OSTI)

X-ray diffraction microscopy (XDM) is well suited for nondestructive, high-resolution biological imaging, especially for thick samples, with the high penetration power of x rays and without limitations imposed by a lens. We developed nonvacuum, cryogenic (cryo-) XDM with hard x rays at 8 keV and report the first frozen-hydrated imaging by XDM. By preserving samples in amorphous ice, the risk of artifacts associated with dehydration or chemical fixation is avoided, ensuring the imaging condition closest to their natural state. The reconstruction shows internal structures of intact D. radiodurans bacteria in their natural contrast.

E Lima; L Wiegart; P Pernot; M Howells; J Timmins; F Zontone; A Madsen

2011-12-31T23:59:59.000Z

256

X-Ray Afterglows from Gamma-Ray Bursts  

Science Journals Connector (OSTI)

We consider possible interpretations of the recently detected X-ray afterglow from the gamma-ray burst source GRB 970228. Cosmological and Galactic models of gamma-ray bursts predict different flux and spectral evolution of X-ray afterglows. We show that models based on adiabatic expansion of relativistic forward shocks require very efficient particle energization or postburst reacceleration during the expansion. Cooling neutron star models predict a very distinctive spectral and flux evolution that can be tested in current X-ray data.

M. Tavani

1997-01-01T23:59:59.000Z

257

Current Problems for X-ray Emission from Radio Jets  

E-Print Network [OSTI]

A list is presented of known extragalactic radio jets which also have associated X-ray emission. The canonical emission processes for the production of X-rays are reviewed and the sources are categorized on the basis of our current understanding. Although it seems clear that the X-ray emission is non-thermal, the two competing processes, synchrotron and inverse Compton emissions, arise from extremely high energy (synchrotron) or extremely low energy (beaming models with IC emission), relativistic electrons. Only synchrotron self-Compton emission from a few hotspots provides information on the `normal' energy range of the electrons responsible for the observed radio emission.

D. E. Harris

2000-12-17T23:59:59.000Z

258

Dynamic model of anisotropic x-ray refraction  

Science Journals Connector (OSTI)

General mechanisms of anisotropic x-ray refraction at the resonance energy are investigated on the basis of dynamic-scattering theory. The deductions show that x rays within the crystals that have anisotropic susceptibility are completely polarized and have two elliptical polarization states. Analytical expressions of the elliptical axes, refractive indices, and absorption coefficients for these two types of polarized waves are obtained in terms of the anisotropic components of the susceptibility tensor. Anisotropic birefringence and dichroism effects associated with the polarization properties of the x-ray waves are also illustrated theoretically.

X. R. Huang, Yong Li, W. J. Liu, and S. S. Jiang

1997-11-01T23:59:59.000Z

259

X-Ray Directional Dichroism of a Polar Ferrimagnet  

Science Journals Connector (OSTI)

In a polar ferrimagnet GaFeO3, we have found a novel magneto-optical effect, termed x-ray nonreciprocal directional dichroism (XNDD), that the x-ray absorption at around the K edge of an Fe ion depends on whether the x-ray propagation vector is parallel or antiparallel to the outer product of the magnetization and electric-polarization vectors. The XNDD spectroscopy as demonstrated here can be a useful tool to probe the local magnetism in noncentrosymmetric systems such as magnetic interfaces and nanostructures.

M. Kubota, T. Arima, Y. Kaneko, J. P. He, X. Z. Yu, and Y. Tokura

2004-03-29T23:59:59.000Z

260

Characterization of X-ray generator beam profiles.  

SciTech Connect (OSTI)

T to compute the radiography properties of various materials, the flux profiles of X-ray sources must be characterized. This report describes the characterization of X-ray beam profiles from a Kimtron industrial 450 kVp radiography system with a Comet MXC-45 HP/11 bipolar oil-cooled X-ray tube. The empirical method described here uses a detector response function to derive photon flux profiles based on data collected with a small cadmium telluride detector. The flux profiles are then reduced to a simple parametric form that enables computation of beam profiles for arbitrary accelerator energies.

Mitchell, Dean J; Harding, Lee T.; Thoreson, Gregory G.; Theisen, Lisa Anne; Parmeter, John Ethan; Thompson, Kyle Richard

2013-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Spatiotemporal focusing dynamics in plasmas at X-ray wavelength  

SciTech Connect (OSTI)

Using a finite curvature beam, we investigate here the spatiotemporal focusing dynamics of a laser pulse in plasmas at X-ray wavelength. We trace the dependence of curvature parameter on the focusing of laser pulse and recognize that the self-focusing in plasma is more intense for the X-ray laser pulse with curved wavefront than with flat wavefront. The simulation results demonstrate that spatiotemporal focusing dynamics in plasmas can be controlled with the appropriate choice of beam-plasma parameters to explore the high intensity effects in X-ray regime.

Sharma, A., E-mail: a-physics2001@yahoo.com; Tibai, Z. [Institute of Physics, University of Pecs, Pecs–7624 (Hungary)] [Institute of Physics, University of Pecs, Pecs–7624 (Hungary); Hebling, J. [Institute of Physics, University of Pecs, Pecs–7624 (Hungary) [Institute of Physics, University of Pecs, Pecs–7624 (Hungary); Szentagothai Research Centre, University of Pecs, Pecs-7624 (Hungary); Mishra, S. K. [Institute for Plasma Research, Gandhinagar (India)] [Institute for Plasma Research, Gandhinagar (India)

2014-03-15T23:59:59.000Z

262

Soft x-ray resist characterization: Studies with a laser plasma x-ray source  

SciTech Connect (OSTI)

Little work has been performed to characterize the exposure sensitivity, contrast, and tone of candidate resists for photon energies between 100--300 eV, the range in which projection soft x-ray lithography will be developed. We report here the characterization of near-edge x-ray absorption fine structure (NEXAFS) spectra, exposure sensitivity, contrast, and post-exposure processing of selected polysilane resists at photon energies close to the Si L{sub 2,3} absorption edge (100 eV). We find absorption resonance features in the NEXAFS spectra which we assign to excitation into Si--Si and Si--C {sigma}* orbitals. Using monochromatized XUV exposures on the Si--Si {sigma}* resonance at 105 eV, followed by solvent dissolution development, we have measured the exposure sensitivity curves of these resists. We find sensitivities in the range of 600--3000 mJ/cm{sup 2} and contrasts in the range from 0.5--1.4, depending on the polysilane side chain. We have also performed exposure sensitivity measurements at 92 eV, below the edge. Sensitivity decreases slightly compared to 105 eV exposures and the saturation depth and contrast both increase, as expected. We find also that exposing resist films to oxygen after XUV exposure, but before development increases the sensitivity markedly. 7 figs.

Kubiak, G.D.; Outka, D.A. (Sandia National Labs., Livermore, CA (USA)); Zeigler, J.M. (Sandia National Labs., Albuquerque, NM (USA))

1990-01-01T23:59:59.000Z

263

Thermonuclear (Type I) X-Ray Bursts Observed by the Rossi X-Ray Timing Explorer  

Science Journals Connector (OSTI)

We have assembled a sample of 1187 thermonuclear (type I) X-ray bursts from observations of 48 accreting neutron stars by the Rossi X-ray Timing Explorer, spanning more than 10 years. The sample contains examples of two of the three theoretical ignition regimes (confirmed via comparisons with numerical models) and likely examples of the third. We present a detailed analysis of the variation of the burst profiles, energetics, recurrence times, presence of photospheric radius expansion, and presence of burst oscillations, as a function of accretion rate. We estimated the distance for 35 sources exhibiting radius-expansion bursts, and found that the peak flux of such bursts varies typically by 13%. We classified sources into two main groups based on the burst properties: (1) both long and short bursts (indicating mixed H/He accretion), and (2) consistently short bursts (primarily He accretion), and we calculated the mean burst rate as a function of accretion rate for the two groups. The decrease in burst rate observed at > 0.06Edd$0.06˙{M}Edd$ --> ( -->2 ? 1037 ergs s?1) is associated with a transition in the persistent spectral state and (as has been suggested previously) may be related to the increasing role of steady He burning. We found many examples of bursts with recurrence times

Duncan K. Galloway; Michael P. Muno; Jacob M. Hartman; Dimitrios Psaltis; Deepto Chakrabarty

2008-01-01T23:59:59.000Z

264

A Laboratory-based Hard X-ray Monochromator for High-Resolution X-ray Emission Spectroscopy and X-ray Absorption Near Edge Structure Measurements  

E-Print Network [OSTI]

We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low poer x-ray (bremsstrahlung) tube source, a spherically-bent crystal analyzer (SBCA), and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of 5 keV to 10 keV while also dmeonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy (XES) comparable to those achived at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure (XANES), the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-powered line-foc...

Seidler, G T; Remesnik, A J; Pacold, J I; Ball, N A; Barry, N; Styczinski, M; Hoidn, O R

2014-01-01T23:59:59.000Z

265

Synchrotron-Radiation Induced X-Ray Emission (SRIXE)  

SciTech Connect (OSTI)

Elemental analysis using emission of characteristic x rays is a well-established scientific method. The success of this analytical method is highly dependent on the properties of the source used to produce the x rays. X-ray tubes have long existed as a principal excitation source, but electron and proton beams have also been employed extensively. The development of the synchrotron radiation x-ray source that has taken place during the past 40 years has had a major impact on the general field of x-ray analysis. Even tier 40 years, science of x-ray analysis with synchrotron x-ray beams is by no means mature. Improvements being made to existing synchrotron facilities and the design and construction of new facilities promise to accelerate the development of the general scientific use of synchrotron x-ray sources for at least the next ten years. The effective use of the synchrotron source technology depends heavily on the use of high-performance computers for analysis and theoretical interpretation of the experimental data. Fortunately, computer technology has advanced at least as rapidly as the x-ray technology during the past 40 years and should continue to do so during the next decade. The combination of these technologies should bring about dramatic advances in many fields where synchrotron x-ray science is applied. It is interesting also to compare the growth and rate of acceptance of this particular research endeavor to the rates for other technological endeavors. Griibler [1997] cataloged the time required for introduction, diffusion,and acceptance of technological, economic, and social change and found mean values of 40 to 50 years. The introduction of the synchrotron source depends on both technical and non-technical factors, and the time scale at which this seems to be occurring is quite compatible with what is seen for other major innovations such as the railroad or the telegraph. It will be interesting to see how long the present rate of technological change and increase in scientific use can be maintained for the synchrotron x-ray source. A short summary of the present state of the synchrotron radiation-induced x-ray emission (SRIXE) method is presented here. Basically, SRIXE experiments can include any that depend on the detection. of characteristic x-rays produced by the incident x-ray beam born the synchrotron source as they interact with a sample. Thus, experiments done to measure elemental composition, chemical state, crystal, structure, and other sample parameters can be considered in a discussion of SRIXE. It is also clear that the experimentalist may well wish to use a variety of complementary techniques for study of a given sample. For this reason, discussion of computed microtomography (CMT) and x-ray diffraction is included here. It is hoped that this present discussion will serve as a succinct introduction to the basic ideas of SRIXE for those not working in the field and possibly help to stimulate new types of work by those starting in the field as well as by experienced practitioners of the art. The topics covered include short descriptions of (1) the properties of synchrotron radiation, (2) a description of facilities used for its production, (3) collimated microprobe, (4) focused microprobes, (5) continuum and monoenergetic excitation, (6) detection limits, (7) quantitation, (8) applications of SRIXE, (9) computed microtomography (CMT), and (10)chemical speciation using x-ray absorption near-edge structure (XANES) and extended x-ray absorption fine structure (EXAFS). An effort has been made to cite a wide variety of work from different laboratories to show the vital nature of the field.

Jones, Keith W.

1999-09-01T23:59:59.000Z

266

E-Print Network 3.0 - airborne lead x-ray Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Pulsars... you'd . . . Active Galactic . . . X-ray binaries Pulsars and relatives Gamma-ray bursts Gravitational... 1 - Type 2 X-ray binaries - Low mass X-ray binaries (LMXBs)...

267

E-Print Network 3.0 - advanced x-ray timing Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AND COMETS: RELATIONSHIP WITH SOLAR X-RAYS AND SOLAR WIND Summary: with the occurrence of solar X-ray flare, when light travel time delay is accounted, suggesting that X-rays...

268

X-RAY ABSORPTION STUDIES OF GRAPHITE INTERCALATES AND METAL-AMMONIA SOLUTION  

E-Print Network [OSTI]

I. INTRODUCTION A. X-Ray Absorption Spectroscopy B. Graphiteacknowledged. The X-Ray absorption data could not have beenI INTRODUCTION X-ray absorption, spectroscopy (XAS) has been

Robertson, A.S.

2010-01-01T23:59:59.000Z

269

AN X-RAY ABSORPTION SPECTROSCOPY STUDY OF MANGANESE CONTAINING COMPOUNDS AND PHOTOSYNTHETIC SPINACH CHLOROPLASTS  

E-Print Network [OSTI]

II. Extended X-ray Absorption Fine Structure (EXAFS) TheoryIII. X-ray Absorption Spectroscopy (XAS) ExperimentIII. EXTENDED X-RAY ABSORPTION FINE STRUCTURE (EXAFS) DATA

Kirby, Jon Allan

2012-01-01T23:59:59.000Z

270

X-ray Absorption Spectroscopy Study of Prototype Chemical Systems: Theory vs. Experiment  

E-Print Network [OSTI]

acids by Near Edge X-ray Absorption Fine Structure (NEXAFS)X-ray Absorption Spectroscopy Study of Prototype ChemicalGlaeser Spring 2010 X-ray Absorption Spectroscopy Study of

Schwartz, Craig Philip

2010-01-01T23:59:59.000Z

271

X-ray absorption spectroscopy at the Ni-K edge in Stackhousia tryonii Bailey hyperaccumulator  

E-Print Network [OSTI]

X-ray absorption spectroscopy at the Ni–K edge inin vivo by micro x-ray absorption spectroscopy (XAS) at theNi–K edge. Both x-ray absorption near edge structure and

Kachenko, A.

2009-01-01T23:59:59.000Z

272

Definition: Portable X-Ray Diffraction (XRD) | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Portable X-Ray Diffraction (XRD) Jump to: navigation, search Dictionary.png Portable X-Ray Diffraction (XRD) Portable X-Ray Diffraction (XRD) is a field-based technique that can be used for identification of crystalline materials and analysis of unit cell dimensions. Portable XRD analysis is similar to X-ray powder diffraction, which has traditionally been used in geology, environmental science, material science, and engineering to rapidly identify unknown crystalline substances. Portable XRD analysis allows for simpler sample preparation, faster analytical times than traditional methods (less than 2 minutes), and can be performed at the sampling site in the field. A pure, finely ground

273

Plasma debris sputter resistant x-ray mirror  

Science Journals Connector (OSTI)

A diamond-like carbon (DLC) mirror, used as a grazing incident mirror in a plasma x-ray source, exhibits a high resistance to plasma debris sputtering. Good mirror reflectivity at a...

Amano, Sho; Inoue, Tomoaki; Harada, Tetsuo

2013-01-01T23:59:59.000Z

274

New Directions in X-ray Scattering - SSRL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6, 2006 A summary of the workshop on New Directions in X-ray Scattering On Dec 6th, we held a day long workshop to solicit user input on the new directions that the SSRL...

275

Synchroton X-Ray Studies of Liquid-Vapor Interfaces  

Science Journals Connector (OSTI)

The variation of density across the liquid-vapor interface from essentially zero density far out in the vapor phase to a homogeneous density deep in the liquid phase can be determined by X-ray reflectivity mea...

J. Als-Nielsen

1988-01-01T23:59:59.000Z

276

Energy weighted x-ray dark-field imaging  

Science Journals Connector (OSTI)

The dark-field image obtained in grating-based x-ray phase-contrast imaging can provide information about the objects’ microstructures on a scale smaller than the pixel size...

Pelzer, Georg; Zang, Andrea; Anton, Gisela; Bayer, Florian; Horn, Florian; Kraus, Manuel; Rieger, Jens; Ritter, Andre; Wandner, Johannes; Weber, Thomas; Fauler, Alex; Fiederle, Michael; Wong, Winnie S; Campbell, Michael; Meiser, Jan; Meyer, Pascal; Mohr, Jürgen; Michel, Thilo

2014-01-01T23:59:59.000Z

277

Magnetic fields of neutron stars in X-ray binaries  

E-Print Network [OSTI]

A substantial fraction of the known neutron stars resides in X-ray binaries -- systems in which one compact object accretes matter from a companion star. Neutron stars in X-ray binaries have magnetic fields among the highest found in the Universe, spanning at least the range from $\\sim10^8$ to several 10$^{13}$ G. The magnetospheres around these neutron stars have a strong influence on the accretion process, which powers most of their emission. The magnetic field intensity and geometry, are among the main factors responsible for the large variety of spectral and timing properties observed in the X-ray energy range, making these objects unique laboratories to study the matter behavior and the radiation processes in magnetic fields unaccessible on Earth. In this paper we review the main observational aspects related to the presence of magnetic fields in neutron star X-ray binaries and some methods that are used to estimate their strength.

Revnivtsev, Mikhail

2014-01-01T23:59:59.000Z

278

X-ray emission from the terrestrial magnetosheath  

E-Print Network [OSTI]

[1] X-rays are generated throughout the terrestrial magnetosheath as a consequence of charge transfer collisions between heavy solar wind ions and geocoronal neutrals. The solar wind ions resulting from these collisions ...

Robertson, Ina Picket; Cravens, Thomas Edward

2003-04-29T23:59:59.000Z

279

Lensless Imaging of Magnetic Nanostructures by X-ray Spectro...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

co-workers. Their implementation of the technique is an extension of lensless Fourier transform holography to the x-ray regime, which detects the far field diffraction pattern of a...

280

Spectroscopic imaging, diffraction, and holography with x-ray photoemission  

SciTech Connect (OSTI)

X-ray probes are capable of determining the spatial structure of an atom in a specific chemical state, over length scales from about a micron all the way down to atomic resolution. Examples of these probes include photoemission microscopy, energy-dependent photoemission diffraction, photoelectron holography, and X-ray absorption microspectroscopy. Although the method of image formation, chemical-state sensitivity, and length scales can be very different, these X-ray techniques share a common goal of combining a capability for structure determination with chemical-state specificity. This workshop will address recent advances in holographic, diffraction, and direct imaging techniques using X-ray photoemission on both theoretical and experimental fronts. A particular emphasis will be on novel structure determinations with atomic resolution using photoelectrons.

Not Available

1992-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Polarization Entangled Photons at X-Ray Energies  

E-Print Network [OSTI]

We show that polarization entangled photons at x-ray energies can be generated via spontaneous parametric down conversion. Each of the four Bell states can be generated by choosing the angle of incidence and polarization of the pumping beam.

S. Shwartz; S. E. Harris

2010-12-16T23:59:59.000Z

282

Towards hard x-ray imaging at GHz frame rate  

SciTech Connect (OSTI)

Gigahertz (GHz) imaging using hard x-rays ( Greater-Than-Or-Equivalent-To 10 keV) can be useful to high-temperature plasma experiments, as well as research and applications using coherent photons from synchrotron radiation and x-ray free electron lasers. GHz framing rate can be achieved by using multiple cameras through multiplexing. The advantages and trade-offs of single-photon detection mode, when no more than one x-ray photon is detected per pixel, are given. Two possible paths towards x-ray imaging at GHz frame rates using a single camera are: (a) avalanche photodiode arrays of high-Z materials and (b) microchannel plate photomultipliers in conjunction with materials with large indices of refraction.

Wang Zhehui; Morris, C. L.; Kapustinsky, J. S.; Kwiatkowski, K.; Luo, S.-N. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

2012-10-15T23:59:59.000Z

283

Towards hard X-ray imaging at GHz frame rate  

SciTech Connect (OSTI)

Gigahertz (GHz) imaging using hard X-rays ({approx}> 10 keV) can be useful to high-temperature plasma experiments, as well as research using coherent photons from synchrotron radiation and X-ray free electron lasers. GHz framing rate can be achieved by using multiple cameras through multiplexing. The advantages and trade-offs of single-photon detection mode, when no more than one X-ray photon is detected per pixel, are given. Two possible paths towards X-ray imaging at GHz frame rates using a single camera are (a) Avalanche photodiode arrays of high-Z materials and (b) Microchannel plate photomultipliers in conjunction with materials with large indices of refraction.

Wang, Zhehui [Los Alamos National Laboratory; Morris, Christopher [Los Alamos National Laboratory; Luo, Shengnian [Los Alamos National Laboratory; Kwiatkowski, Kris K. [Los Alamos National Laboratory; Kapustinsky, Jon S. [Los Alamos National Laboratory

2012-05-02T23:59:59.000Z

284

Magnetism studies using resonant, coherent, x-ray scattering...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Magnetism studies using resonant, coherent, x-ray scattering Monday, September 10, 2012 - 10:00am SLAC, Bldg. 137, Room 226 Keoki Seu Seminar: With the advent of free electron...

285

Copyright The Discussion Group of X-Ray Analysis,  

E-Print Network [OSTI]

-2900. 3 In Situ Spatial and Time-Resolved Studies of Electrochemical Reactions by Scanning Transmission X the Signal-to-Noise Ratio of X-ray Diffraction Profiles by Smoothed Principal Component Analysis Zeng Ping

Jun, Kawai

286

X-Ray Astronomy to Resonant Theranostics for Cancer Treatment  

E-Print Network [OSTI]

X-Ray Astronomy to Resonant Theranostics for Cancer Treatment Sultana N. Nahar Department-Plasma Theranostics or RNPT, which gives indication for one most efficient way for destruction of malignant cells. 1

Nahar, Sultana Nurun

287

Vitreous carbon mask substrate for X-ray lithography  

DOE Patents [OSTI]

The present invention is directed to the use of vitreous carbon as a substrate material for providing masks for X-ray lithography. The new substrate also enables a small thickness of the mask absorber used to pattern the resist, and this enables improved mask accuracy. An alternative embodiment comprised the use of vitreous carbon as a LIGA substrate wherein the VC wafer blank is etched in a reactive ion plasma after which an X-ray resist is bonded. This surface treatment provides a surface enabling good adhesion of the X-ray photoresist and subsequent nucleation and adhesion of the electrodeposited metal for LIGA mold-making while the VC substrate practically eliminates secondary radiation effects that lead to delamination of the X-ray resist form the substrate, the loss of isolated resist features, and the formation of a resist layer adjacent to the substrate that is insoluble in the developer.

Aigeldinger, Georg (Livermore, CA); Skala, Dawn M. (Fremont, CA); Griffiths, Stewart K. (Livermore, CA); Talin, Albert Alec (Livermore, CA); Losey, Matthew W. (Livermore, CA); Yang, Chu-Yeu Peter (Dublin, CA)

2009-10-27T23:59:59.000Z

288

Optical and X-ray Variability of AGNs  

E-Print Network [OSTI]

I present new comparisons of AGN optical, UV, and X-ray variations. These reveal complex relationships between the different passbands that can change with time in a given object. While there is evidence from several objects that X-ray and optical activity levels are correlated on long timescales, variations on shorter timescales can occur independently. It is proposed that the combination of correlated and uncorrelated short-timescale variability is a consequence of anisotropic high-energy emission. It is also argued that the correlation between X-ray and optical variability on long timescales must be due to a common underlying factor and not to reprocessing of X-ray radiation.

C. Martin Gaskell

2006-12-30T23:59:59.000Z

289

,~ Abstract Submitted to 1997 Denver X-Ray Conference  

E-Print Network [OSTI]

,~ Abstract Submitted to 1997 Denver X-Ray Conference Denver, Colorado -August 4-8, 1997 BNL-.64346 being distributed through the entire volume of the particle needs further investigation. *Work supported

Brookhaven National Laboratory

290

Photon Sciences | Beamlines | SRX: Submicron Resolution X-ray Spectroscopy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

SRX: Submicron Resolution X-ray Spectroscopy SRX: Submicron Resolution X-ray Spectroscopy Poster | Fact Sheet | Preliminary Design Report Scientific Scope Scientific communities such as environmental sciences, life sciences, and material sciences have identified the need to develop analytical resources to advance the understanding of complex natural and engineered systems that are heterogeneous on the micron to nanometer scale. These needs for high intensity x-ray nanoprobes resulted in the commitment of the NSLS-II Project to build the Submicron Resolution X-ray (SRX) Spectroscopy beamline showing a unique combination of high spectral resolution over a very broad energy range and very high beam intensity in a sub-micrometer spot. NSLS-II will provide one of the best sources in the world for such an instrument.

291

X-ray Raman scattering study of aligned polyfluorene  

E-Print Network [OSTI]

We present a non-resonant inelastic x-ray scattering study at the carbon K-edge on aligned poly[9,9-bis(2-ethylhexyl)-fluorene-2,7-diyl] and show that the x-ray Raman scattering technique can be used as a practical alternative to x-ray absorption measurements. We demonstrate that this novel method can be applied to studies on aligned $\\pi$-conjugated polymers complementing diffraction and optical studies. Combining the experimental data and a very recently proposed theoretical scheme we demonstrate a unique property of x-ray Raman scattering by performing the symmetry decomposition on the density of unoccupied electronic states into $s$- and $p$-type symmetry contributions.

S. Galambosi; M. Knaapila; J. A. Soininen; K. Nyg\\aard; S. Huotari; F. Galbrecht; U. Scherf; A. P. Monkman; K. Hämäläinen

2006-08-29T23:59:59.000Z

292

X-Ray Photoelectron Spectroscopy (XPS) Applied to Soot & What...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Photoelectron Spectroscopy (XPS) Applied to Soot & What It Can Do for You X-Ray Photoelectron Spectroscopy (XPS) Applied to Soot & What It Can Do for You Presentation given at DEER...

293

Gravitational and Relativistic Deflection of X-Ray Superradiance  

E-Print Network [OSTI]

Exploring Einstein's theories of relativity in quantum systems, for example by using atomic clocks at high speeds can deepen our knowledge in physics. However, many challenges still remain on finding novel methods for detecting effects of gravity and of special relativity and their roles in light-matter interaction. Here we introduce a scheme of x-ray quantum optics that allows for a millimeter scale investigation of the relativistic redshift by directly probing a fixed nuclear crystal in Earth's gravitational field with x-rays. Alternatively, a compact rotating crystal can be used to force interacting x-rays to experience inhomogeneous clock tick rates in a crystal. We find that an association of gravitational or special-relativistic time dilation with quantum interference will be manifested by deflections of x-ray photons. Our protocol suggests a new and feasible tabletop solution for probing effects of gravity and special relativity in the quantum world.

Wen-Te Liao; Sven Ahrens

2014-11-27T23:59:59.000Z

294

High performance x-ray anti-scatter grid  

DOE Patents [OSTI]

Disclosed are an x-ray anti-scatter grid for x-ray imaging, particularly for screening mammography, and method for fabricating same, x-rays incident along a direct path pass through a grid composed of a plurality of parallel or crossed openings, microchannels, grooves, or slots etched in a substrate, such as silicon, having the walls of the microchannels or slots coated with a high opacity material, such as gold, while x-rays incident at angels with respect to the slots of the grid, arising from scatter, are blocked. The thickness of the substrate is dependent on the specific application of the grid, whereby a substrate of the grid for mammography would be thinner than one for chest radiology. Instead of coating the walls of the slots, such could be filed with an appropriate liquid, such as mercury. 4 Figs.

Logan, C.M.

1995-05-23T23:59:59.000Z

295

Pixel detectors for x-ray imaging spectroscopy in space  

Science Journals Connector (OSTI)

Pixelated semiconductor detectors for X-ray imaging spectroscopy are foreseen as key components of the payload of various future space missions exploring the x-ray sky. Located on the platform of the new Spectrum-Roentgen-Gamma satellite, the eROSITA (extended Roentgen Survey with an Imaging Telescope Array) instrument will perform an imaging all-sky survey up to an X-ray energy of 10 keV with unprecedented spectral and angular resolution. The instrument will consist of seven parallel oriented mirror modules each having its own pnCCD camera in the focus. The satellite born X-ray observatory SIMBOL-X will be the first mission to use formation-flying techniques to implement an X-ray telescope with an unprecedented focal length of around 20 m. The detector instrumentation consists of separate high- and low energy detectors, a monolithic 128 ? 128 DEPFET macropixel array and a pixellated CdZTe detector respectively, making energy band between 0.5 to 80 keV accessible. A similar concept is proposed for the next generation X-ray observatory IXO. Finally, the MIXS (Mercury Imaging X-ray Spectrometer) instrument on the European Mercury exploration mission BepiColombo will use DEPFET macropixel arrays together with a small X-ray telescope to perform a spatially resolved planetary XRF analysis of Mercury's crust. Here, the mission concepts and their scientific targets are briefly discussed, and the resulting requirements on the detector devices together with the implementation strategies are shown.

J Treis; R Andritschke; R Hartmann; S Herrmann; P Holl; T Lauf; P Lechner; G Lutz; N Meidinger; M Porro; R H Richter; F Schopper; H Soltau; L Strüder

2009-01-01T23:59:59.000Z

296

The Hard X-ray Sky: Recent Observational Progress  

SciTech Connect (OSTI)

The last fifty years have witnessed the birth, development, and maturation to full potential of hard X-ray astrophysics. The primary force driving the history of the field has been the development of space-based instrumentation optimized for getting the maximum science out of observations of high-energy photons from astrophysical sources. Hard X-ray telescopes are leading research in areas such as galactic diffuse emission, galactic transients, and active galactic nuclei.

Gehrels, Neil [NASA/GSFC/ASD/Code 661, Greenbelt, Md 20071 (United States); Cannizzo, John K. [CRESST/UMBC/NASA/GSFC/ASD/Code 661, Greenbelt, Md 20071 (United States)

2009-05-11T23:59:59.000Z

297

The X-ray background and the evolution of AGN  

E-Print Network [OSTI]

We discuss the constraints on the AGN evolution from the cosmic X-ray background and source counts. A synthesis model to fit the X-ray background is presented. In the model, the spectrum of type 2 AGN has been modeled including Compton down--scattering within the absorbing material. Besides, we introduced a dependence on redshift of the relative number of obscured sources and found a decrease of the fraction of type 2 AGN at redshifts larger than 2.

Fulvio Pompilio; Fabio La Franca; Giorgio Matt

1999-09-23T23:59:59.000Z

298

Sapphire analyzers for high-resolution x-ray spectroscopy.  

SciTech Connect (OSTI)

We present a sapphire (Al{sub 2}O{sub 3}) analyzer for high-resolution X-ray spectroscopy with 31-meV energy resolution. The analyzer is designed for resonant inelastic X-ray scattering (RIXS) measurements at the CuK{sub a} absorption edge near 8990 eV. The performance of the analyzer is demonstrated by measuring phonon excitations in beryllium because of its known dynamical structure and high counting rates.

Yavas, H.; Alp, E.; Sinn, H.; Alatas, A.; Said, A.; Shvydko, Y.; Toellner, T.; Khachatryan, R.; Billinge, S.; Hasan, Z.; Sturhahn, W.; Michigan State Univ.; Princeton Univ.; DESY

2007-11-11T23:59:59.000Z

299

X-ray tube with magnetic electron steering  

DOE Patents [OSTI]

An X-ray tube uses a magnetic field to steer electrons. The magnetic field urges electrons toward the anode, increasing the proportion of electrons emitted from the cathode that reach desired portions of the anode and consequently contribute to X-ray production. The magnetic field also urges electrons reflected from the anode back to the anode, further increasing the efficiency of the tube.

Reed, Kim W. (Albuquerque, NM); Turman, Bobby N. (Albuquerque, NM); Kaye, Ronald J. (Albuquerque, NM); Schneider, Larry X. (Albuquerque, NM)

2000-01-01T23:59:59.000Z

300

Ris-M-2751 X-Ray Energy Dispersive  

E-Print Network [OSTI]

(PHOT) k«V 50 Risø National Laboratory, DK-4000 Roskilde, Denmark October 1988 #12;Ris*-M-2751 X-ray energy is impinging on the sample (Fig. lb). Its wavelength (photon energy) is in the course of measurements changedm ii. S Risø-M-2751 X-Ray Energy Dispersive Diffraction Lecture Notes Bronislaw Buras BaKo 30 40 E

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

A compact scanning soft X-ray microscope  

SciTech Connect (OSTI)

Soft x-ray microscopes operating at wavelengths between 2.3 nm and 4.4 nm are capable of imaging wet biological cells with a resolution many times that of a visible light microscope. Several such soft x-ray microscopes have been constructed. However, with the exception of contact microscopes, all use synchrotrons as the source of soft x-ray radiation and Fresnel zone plates as the focusing optics. These synchrotron based microscopes are very successful but have the disadvantage of limited access. This dissertation reviews the construction and performance of a compact scanning soft x-ray microscope whose size and accessibility is comparable to that of an electron microscope. The microscope uses a high-brightness laser-produced plasma as the soft x-ray source and normal incidence multilayer-coated mirrors in a Schwarzschild configuration as the focusing optics. The microscope operates at a wavelength of 14 nm, has a spatial resolution of 0.5 {mu}m, and has a soft x-ray photon flux through the focus of 10{sup 4}-10{sup 5} s{sup {minus}1} when operated with only 170 mW of average laser power. The complete system, including the laser, fits on a single 4{prime} x 8{prime} optical table. The significant components of the compact microscope are the laser-produced plasma (LPP) source, the multilayer coatings, and the Schwarzschild objective. These components are reviewed, both with regard to their particular use in the current microscope and with regard to extending the microscope performance to higher resolution, higher speed, and operation at shorter wavelengths. Measurements of soft x-ray emission and debris emission from our present LPP source are presented and considerations given for an optimal LPP source. The LPP source was also used as a broadband soft x-ray source for measurement of normal incidence multilayer mirror reflectance in the 10-25 nm spectral region.

Trail, J.A.

1989-01-01T23:59:59.000Z

302

New Directions in X-Ray Light Sources  

ScienceCinema (OSTI)

July 15, 2008 Berkeley Lab lecture: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.

Roger Falcone

2010-01-08T23:59:59.000Z

303

X-Ray Diffraction Studies of Copper Nanopowder  

E-Print Network [OSTI]

Copper nanopowder preparation and its X-Ray diffraction studies are reported in this paper. Electrolytic cathode deposition method is simple and cheapest process for its preparation. Copper nanopowder has been prepared from aqueous copper sulphate solution. Wide range of experimental conditions has been adopted in this process and its X-Ray diffraction characterizations have been studied. The results confirming copper nanopowder with size below 30 nm. Uniformed size Copper nanopowder preparation, in normal room temperature is importance of this study.

T. Theivasanthi; M. Alagar

2010-03-31T23:59:59.000Z

304

E-Print Network 3.0 - anomalous small-angle x-ray Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2008Standard Operating Procedure Title: Small Angle X-ray Scattering... approved: December 26 2009 Small Angle X-ray Scattering, Rotating Anode PURPOSE: This Standard...

305

E-Print Network 3.0 - angle x-ray scattering Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2008Standard Operating Procedure Title: Small Angle X-ray Scattering... approved: December 26 2009 Small Angle X-ray Scattering, Rotating Anode PURPOSE: This Standard...

306

X-RAY ABSORPTION SPECTROSCOPY FOR THE CHEMICAL CHARACTERIZATION OF ATMOSPHERIC AEROSOLS  

E-Print Network [OSTI]

November 11-16 9 1979 X-RAY ABSORPTION SPECTROSCOPY FOR THEUniversity of California. ABSORPTION SPECTROSCOPY FOR THEand x-ray emission and absorption spectroscopy. The first

Jaklevic, J. M.

2011-01-01T23:59:59.000Z

307

Ultrafast X-ray Phase-Enhanced Microimaging for Visualizing Fuel...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Ultrafast X-ray Phase-Enhanced Microimaging for Visualizing Fuel Injection Process and Diesel Sprays Ultrafast X-ray Phase-Enhanced Microimaging for Visualizing Fuel Injection...

308

Soft X-Ray Microscopy and Spectroscopy at the Molecular Environmental...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Soft X-Ray Microscopy and Spectroscopy at the Molecular Environmental Science Beamline at the Advanced Light Source. Soft X-Ray Microscopy and Spectroscopy at the Molecular...

309

Synchrotron X-ray Studies of Super-critical Carbon Dioxide /...  

Broader source: Energy.gov (indexed) [DOE]

Synchrotron X-ray Studies of Super-critical Carbon Dioxide Reservoir Rock Interfaces Synchrotron X-ray Studies of Super-critical Carbon Dioxide Reservoir Rock Interfaces...

310

Using Light to Control How X Rays Interact with Matter  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Using Light to Control How X Using Light to Control How X Rays Interact with Matter Using Light to Control How X Rays Interact with Matter Print Wednesday, 27 January 2010 00:00 Schemes that use one light pulse to manipulate interactions of another with matter are well developed in the visible-light regime where an optical control pulse influences how an optical probe pulse interacts with a medium. This approach has opened new research directions in fields like quantum computing and nonlinear optics, while also spawning entirely new research areas, such as electromagnetically induced transparency and slow light. However, it has been unclear whether similar optical control schemes could be used to modify how x rays interact with matter. In a dramatic breakthrough demonstration at the ALS, a Berkeley Lab-Argonne National Laboratory group has now used powerful visible-light lasers to render a nominally opaque material transparent to x rays. While x-ray transparency will have immediate applications at x-ray light sources, the important result is that the findings lay a foundation for a broader spectrum of applications.

311

Using Light to Control How X Rays Interact with Matter  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Using Light to Control How X Rays Interact with Matter Print Using Light to Control How X Rays Interact with Matter Print Schemes that use one light pulse to manipulate interactions of another with matter are well developed in the visible-light regime where an optical control pulse influences how an optical probe pulse interacts with a medium. This approach has opened new research directions in fields like quantum computing and nonlinear optics, while also spawning entirely new research areas, such as electromagnetically induced transparency and slow light. However, it has been unclear whether similar optical control schemes could be used to modify how x rays interact with matter. In a dramatic breakthrough demonstration at the ALS, a Berkeley Lab-Argonne National Laboratory group has now used powerful visible-light lasers to render a nominally opaque material transparent to x rays. While x-ray transparency will have immediate applications at x-ray light sources, the important result is that the findings lay a foundation for a broader spectrum of applications.

312

Using Light to Control How X Rays Interact with Matter  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Using Light to Control How X Rays Interact with Matter Print Using Light to Control How X Rays Interact with Matter Print Schemes that use one light pulse to manipulate interactions of another with matter are well developed in the visible-light regime where an optical control pulse influences how an optical probe pulse interacts with a medium. This approach has opened new research directions in fields like quantum computing and nonlinear optics, while also spawning entirely new research areas, such as electromagnetically induced transparency and slow light. However, it has been unclear whether similar optical control schemes could be used to modify how x rays interact with matter. In a dramatic breakthrough demonstration at the ALS, a Berkeley Lab-Argonne National Laboratory group has now used powerful visible-light lasers to render a nominally opaque material transparent to x rays. While x-ray transparency will have immediate applications at x-ray light sources, the important result is that the findings lay a foundation for a broader spectrum of applications.

313

Dilation x-ray imager a new/faster gated x-ray imager for the NIF  

SciTech Connect (OSTI)

As the yield on implosion shots increases it is expected that the peak x-ray emission reduces to a duration with a FWHM as short as 20 ps for {approx}7 Multiplication-Sign 10{sup 18} neutron yield. However, the temporal resolution of currently used gated x-ray imagers on the NIF is 40-100 ps. We discuss the benefits of the higher temporal resolution for the NIF and present performance measurements for dilation x-ray imager, which utilizes pulse-dilation technology [T. J. Hilsabeck et al., Rev. Sci. Instrum. 81, 10E317 (2010)] to achieve x-ray imaging with temporal gate times below 10 ps. The measurements were conducted using the COMET laser, which is part of the Jupiter Laser Facility at the Lawrence Livermore National Laboratory.

Nagel, S. R.; Bell, P. M.; Bradley, D. K.; Ayers, M. J.; Barrios, M. A.; Felker, B.; Smith, R. F.; Collins, G. W.; Jones, O. S.; Piston, K.; Raman, K. S. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Hilsabeck, T. J.; Kilkenny, J. D.; Chung, T.; Sammuli, B. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Hares, J. D.; Dymoke-Bradshaw, A. K. L. [Kentech Instruments Ltd., Wallingford, Oxfordshire OX10 (United Kingdom)

2012-10-15T23:59:59.000Z

314

Modeling the high resolution X-ray spectra from the relativistic jets of the X-ray binary SS 433  

E-Print Network [OSTI]

We test the physical model of the relativistic jets in the galactic X-ray binary SS 433 that was proposed by Marshall et al. 2002 (Paper I) using additional observations from the Chandra High Energy Transmission Grating ...

Lopez, Laura Ann, 1982-

2004-01-01T23:59:59.000Z

315

Gain dynamics in a soft X-ray laser ampli er perturbed by a strong injected X-ray eld  

SciTech Connect (OSTI)

Seeding soft X-ray plasma ampli ers with high harmonics has been demonstrated to generate high-brightness soft X-ray laser pulses with full spatial and temporal coherence. The interaction between the injected coherent eld and the swept-gain medium has been modelled. However, no exper- iment has been conducted to probe the gain dynamics when perturbed by a strong external seed eld. Here, we report the rst X-ray pump X-ray probe measurement of the nonlinear response of a plasma ampli er perturbed by a strong soft X-ray ultra-short pulse. We injected a sequence of two time-delayed high-harmonic pulses (l518.9 nm) into a collisionally excited nickel-like molybdenum plasma to measure with femto-second resolution the gain depletion induced by the saturated ampli cation of the high-harmonic pump and its subsequent recovery. The measured fast gain recovery in 1.5 1.75 ps con rms the possibility to generate ultra-intense, fully phase-coherent soft X-ray lasers by chirped pulse ampli cation in plasma ampli ers.

Wang, Yong [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Wang, Shoujun [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Oliva, E [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Lu, L [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Berrill, Mark A [ORNL] [ORNL; Yin, Liang [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Nejdl, J [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Luther, Brad [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Proux, C [Laboratoire d’Optique Applique´e, ENSTA, CNRS, Ecole Polytechnique] [Laboratoire d’Optique Applique´e, ENSTA, CNRS, Ecole Polytechnique; Le, T. T. [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Dunn, James [Lawrence Livermore National Laboratory (LLNL)] [Lawrence Livermore National Laboratory (LLNL); Ros, D [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Zeitoun, Philippe [École Polytechnique] [École Polytechnique; Rocca, Jorge [Colorado State University, Fort Collins] [Colorado State University, Fort Collins

2014-01-01T23:59:59.000Z

316

Diffracted X-ray tracking for monitoring intramolecular motion in individual protein molecules using broad band X-ray  

SciTech Connect (OSTI)

Diffracted X-ray tracking (DXT) enables the tilting and twisting motions of single protein molecules to be monitored with micro- to milliradian resolution using a highly brilliant X-ray source with a wide energy bandwidth. We have developed a technique to monitor single molecules using gold nanocrystals attached to individual protein molecules using the BL28B2 beamline at SPring-8. In this paper we present the installation of a single toroidal X-ray mirror at BL28B2 to focus X-rays in an energy range of 10–20 keV (?E/E = 82% for an X-ray with a wide energy bandwidth). With this beamline we tracked diffraction spots from gold nanocrystals over a wide angle range than that using quasi-monochromatic X-rays. Application of the wide angle DXT technique to biological systems enabled us to observe the on-site motions of single protein molecules that have been functionalized in vivo. We further extend the capability of DXT by observing the fractional tilting and twisting motions of inner proteins under various conditions. As a proof of this methodology and to determine instrumental performance the intramolecular motions of a human serum albumin complex with 2-anthracenecarboxylic acid was investigated using the BL28B2 beamline. The random tilting and twisting intramolecular motions are shown to be directly linked to the movement of individual protein molecules in the buffer solution.

Ichiyanagi, Kouhei; Sasaki, Yuji C. [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan) [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan); Japan Science and Technology Agency, CREST, CREST, Sasaki-Team, 609 Kiban Building, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Sekiguchi, Hiroshi; Hoshino, Masato; Kajiwara, Kentaro; Senba, Yasunori; Ohashi, Haruhiko; Ohta, Noboru [Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)] [Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan); Hoshisashi, Kentaro; Jae-won, Chang; Tokue, Maki; Matsushita, Yufuku [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan)] [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan); Nishijima, Masaki; Inoue, Yoshihisa [Department of Applied Chemistry and Office for University-Industry Collaboration, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)] [Department of Applied Chemistry and Office for University-Industry Collaboration, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Yagi, Naoto [Japan Science and Technology Agency, CREST, CREST, Sasaki-Team, 609 Kiban Building, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan) [Japan Science and Technology Agency, CREST, CREST, Sasaki-Team, 609 Kiban Building, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

2013-10-15T23:59:59.000Z

317

Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism Print Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism Print Using spectroscopic information for magnetometry and magnetic microscopy obviously requires detailed theoretical understanding of spectral shape and magnitude of dichroism signals. A research team at ALS Beamline 4.0.2 has now shown unambiguously that, contrary to common belief, spectral shape and magnitude of x-ray magnetic linear dichroism (XMLD) are not only determined by the relative orientation of magnetic moments and x-ray polarization, but their orientation relative to the crystallographic axes must be taken into account for accurate interpretation of XMLD data. Magnetism and X Rays The ancient Greeks and also the Chinese knew about strange and rare stones with the power to attract iron. Moreover, when freely suspended these objects pointed north-south. Throughout the past, we have used this phenomenon-magnetism-for navigation and more recently for power production and digital information storage, all while trying to explore and understand its origins. In 1986 researchers at a facility similar to the ALS observed for the first time that the absorption of x rays depends not only on the composition of a material-that is, if it contains iron, nickel, or other elements-but also on its magnetism. The effect is unique in that it allows us to distinguish which atomic species magnetism originates from and provides information about their local atomic environment-for example, whether a magnetic species is surrounded by 4 or 6 oxygen atoms. A research team at the ALS has now shown that the relationship between magnetic order and absorption of x rays is even more complex and exciting than has been assumed for the past 20 years, leading to a reassessment of previous results.

318

Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism Print Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism Print Using spectroscopic information for magnetometry and magnetic microscopy obviously requires detailed theoretical understanding of spectral shape and magnitude of dichroism signals. A research team at ALS Beamline 4.0.2 has now shown unambiguously that, contrary to common belief, spectral shape and magnitude of x-ray magnetic linear dichroism (XMLD) are not only determined by the relative orientation of magnetic moments and x-ray polarization, but their orientation relative to the crystallographic axes must be taken into account for accurate interpretation of XMLD data. Magnetism and X Rays The ancient Greeks and also the Chinese knew about strange and rare stones with the power to attract iron. Moreover, when freely suspended these objects pointed north-south. Throughout the past, we have used this phenomenon-magnetism-for navigation and more recently for power production and digital information storage, all while trying to explore and understand its origins. In 1986 researchers at a facility similar to the ALS observed for the first time that the absorption of x rays depends not only on the composition of a material-that is, if it contains iron, nickel, or other elements-but also on its magnetism. The effect is unique in that it allows us to distinguish which atomic species magnetism originates from and provides information about their local atomic environment-for example, whether a magnetic species is surrounded by 4 or 6 oxygen atoms. A research team at the ALS has now shown that the relationship between magnetic order and absorption of x rays is even more complex and exciting than has been assumed for the past 20 years, leading to a reassessment of previous results.

319

Neutron and X-Ray Scattering - Argonne National Laboratories, Materials  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home Home Neutron and X-Ray Scattering Neutron and X-ray Scattering Science Recent advances in neutron and x-ray scattering instrumentation at major DOE facilities such as the Spallation Neutron Source and Advanced Photon Source provide unprecedented insights into complex phenomena in bulk and interfacial materials. The vision of our group is to harness the complementarity of neutrons and x-rays to study how materials respond on a range of length and time scales to phase competition, so that we can learn to control emergent behavior and generate functional properties in energy-related materials. We use neutrons and x-rays to investigate the structure and dynamics of bulk and interfacial materials with properties that are useful for energy applications, such as superconductivity, magnetism and thermoelectricity. Phase competition can generate or enhance such properties, but it is extremely challenging to characterize fluctuations in the competing order, whether in bulk disordered materials, or artificial heterostructures. Our goal is to utilize efficient techniques that we have been developing for measuring nanoscale phase fluctuations, both static and dynamic, to enable the rational design of new materials for energy within MSD.

320

Optics-free x-ray FEL oscillator  

SciTech Connect (OSTI)

There is a need for an Optics-Free FEL Oscillators (OFFELO) to further the advantages of free-electron lasers and turning them in fully coherent light sources. While SASE (Self-Amplified Spontaneous Emission) FELs demonstrated the capability of providing very high gain and short pulses of radiation and scalability to the X-ray range, the spectra of SASE FELs remains rather wide ({approx}0.5%-1%) compared with typical short wavelengths FEL-oscillators (0.01%-0.0003% in OK-4 FEL). Absence of good optics in VUV and X-ray ranges makes traditional oscillator schemes with very high average and peak spectral brightness either very complex or, strictly speaking, impossible. In this paper, we discuss lattice of the X-ray optics-free FEL oscillator and present results of initial computer simulations of the feedback process and the evolution of FEL spectrum in X-ray OFFELO. We also discuss main limiting factors and feasibility of X-ray OFFELO.

Litvinenko, V.N.; Hao, Y.; Kayran, D.; Trbojevic, D.

2011-03-28T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

NuSTAR Observations of X-Ray Binaries  

E-Print Network [OSTI]

As of 2014 August, the Nuclear Spectroscopic Telescope Array (NuSTAR) had observed ~30 X-ray binaries either as part of the planned program, as targets of opportunity, or for instrument calibration. The main science goals for the observations include probing the inner part of the accretion disk and constraining black hole spins via reflection components, providing the first observations of hard X-ray emission from quiescent Low Mass X-ray Binaries (LMXBs), measuring cyclotron lines from accreting pulsars, and studying type I X-ray bursts from neutron stars. Here, we describe the science objectives in more depth and give an overview of the NuSTAR observations that have been carried out to achieve the objectives. These include observation of four "IGR" High Mass X-ray Binaries (HMXBs) discovered by INTEGRAL. We also summarize the results that have been obtained and their implications. Among the IGR HMXBs, we focus on the discovery of a cyclotron line in the spectrum of IGR J17544-2619.

Tomsick, John A; Fuerst, Felix; Harrison, Fiona; Miyasaka, Hiromasa; Tendulkar, Shriharsh; Bhalerao, Varun; Chakrabarty, Deepto; King, Ashley; Miller, Jon M; Natalucci, Lorenzo; Stern, Daniel

2015-01-01T23:59:59.000Z

322

Method and apparatus for micromachining using hard X-rays  

DOE Patents [OSTI]

An X-ray source such as a synchrotron which provides a significant spectral content of hard X-rays is used to expose relatively thick photoresist such that the portions of the photoresist at an exit surface receive at least a threshold dose sufficient to render the photoresist susceptible to a developer, while the entrance surface of the photoresist receives an exposure which does not exceed a power limit at which destructive disruption of the photoresist would occur. The X-ray beam is spectrally shaped to substantially eliminate lower energy photons while allowing a substantial flux of higher energy photons to pass through to the photoresist target. Filters and the substrate of the X-ray mask may be used to spectrally shape the X-ray beam. Machining of photoresists such as polymethylmethacrylate to micron tolerances may be obtained to depths of several centimeters, and multiple targets may be exposed simultaneously. The photoresist target may be rotated and/or translated in the beam to form solids of rotation and other complex three-dimensional structures. 21 figs.

Siddons, D.P.; Johnson, E.D.; Guckel, H.; Klein, J.L.

1997-10-21T23:59:59.000Z

323

Method and apparatus for micromachining using hard X-rays  

DOE Patents [OSTI]

An X-ray source such as a synchrotron which provides a significant spectral content of hard X-rays is used to expose relatively thick photoresist such that the portions of the photoresist at an exit surface receive at least a threshold dose sufficient to render the photoresist susceptible to a developer, while the entrance surface of the photoresist receives an exposure which does not exceed a power limit at which destructive disruption of the photoresist would occur. The X-ray beam is spectrally shaped to substantially eliminate lower energy photons while allowing a substantial flux of higher energy photons to pass through to the photoresist target. Filters and the substrate of the X-ray mask may be used to spectrally shape the X-ray beam. Machining of photoresists such as polymethylmethacrylate to micron tolerances may be obtained to depths of several centimeters, and multiple targets may be exposed simultaneously. The photoresist target may be rotated and/or translated in the beam to form solids of rotation and other complex three-dimensional structures.

Siddons, David Peter (Shoreham, NY); Johnson, Erik D. (Ridge, NY); Guckel, Henry (Madison, WI); Klein, Jonathan L. (Madison, WI)

1997-10-21T23:59:59.000Z

324

The History of X-ray Free-Electron Lasers  

SciTech Connect (OSTI)

The successful lasing at the SLAC National Accelerator Laboratory of the Linear Coherent Light Source (LCLS), the first X-ray free-electron laser (X-ray FEL), in the wavelength range 1.5 to 15 {angstrom}, pulse duration of 60 to few femtoseconds, number of coherent photons per pulse from 10{sup 13} to 10{sup 11}, is a landmark event in the development of coherent electromagnetic radiation sources. Until now electrons traversing an undulator magnet in a synchrotron radiation storage ring provided the best X-ray sources. The LCLS has set a new standard, with a peak X-ray brightness higher by ten orders of magnitudes and pulse duration shorter by three orders of magnitudes. LCLS opens a new window in the exploration of matter at the atomic and molecular scales of length and time. Taking a motion picture of chemical processes in a few femtoseconds or less, unraveling the structure and dynamics of complex molecular systems, like proteins, are some of the exciting experiments made possible by LCLS and the other X-ray FELs now being built in Europe and Asia. In this paper, we describe the history of the many theoretical, experimental and technological discoveries and innovations, starting from the 1960s and 1970s, leading to the development of LCLS.

Pellegrini, C.; /UCLA /SLAC; ,

2012-06-28T23:59:59.000Z

325

Ultrafast x-ray diffraction of laser-irradiated crystals  

SciTech Connect (OSTI)

An apparatus has been developed for measuring time-dependent x-ray diffraction. X-ray pulses from an Advanced Light Source bend magnet are diffracted by a sagittally-focusing Si(111) crystal and then by a sample crystal, presently InSb(111). Laser pulses with 100 fs duration and a repetition rate of 1 KHz irradiate the sample inducing a phase transition. Two types of detectors are being employed: an x-ray streak camera and an avalanche photodiode. The streak camera is driven by a photoconductive switch and has a 2 ps temporal resolution determined by trigger jitter. The avalanche photodiode has high quantum efficiency and sufficient time resolution to detect single x-ray pulses in ALS two bunch or camshaft operation. A beamline is under construction dedicated for time resolved and micro-diffraction experiments. In the new beamline a toroidal mirror collects 3 mrad horizontally and makes a 1:1 image of the bend magnet source in the x-ray hutch. A laser induced phase transition has been observed in InSb occurring within 70 ps.

Heimann, P.A. [Lawrence Berkeley National Lab., CA (US). Advanced Light Source; Larsson, J. [Univ. of California, Berkeley, CA (US). Physics Dept.; Chang, Z. [Univ. of Michigan, Ann Arbor, MI (US). Center for Ultrafast Optical Science

1997-09-01T23:59:59.000Z

326

Implications of the X-Ray Properties of Pulsar Nebulae  

E-Print Network [OSTI]

A plausible model for the Crab Nebula is one in which a particle dominated, highly relativistic wind from the pulsar passes through a shock front in which the particles attain a power law energy distribution. The electrons and positrons lose energy radiating synchrotron emission. Here, a one zone version of the model is developed and applied to observations of X-ray pulsar nebulae. Efficient conversion of pulsar spin-down power to X-ray luminosity is expected if the observed electrons are in the synchrotron cooling regime and their energy spectrum is similar to that in the Crab Nebula. In this case, the relation between X-ray luminosity and pulsar spin-down power depends only weakly on the model parameters. The dependence is stronger for a steeper particle spectrum, as appears to be present in N157B, and the efficiency of X-ray production can be lower. If the electrons are not in the cooling regime, the X-ray luminosity can be low, as appears to be the case for the compact nebula around the Vela pulsar. Slow cooling is likely to be caused by a sub-equipartition magnetic field in the radiating region. Observations can place constraints on the uncertain physics of relativistic MHD shocks. The model is related to those developed for gamma-ray burst afterglows.

Roger A. Chevalier

2000-06-01T23:59:59.000Z

327

ON THE X-RAY OUTBURSTS OF TRANSIENT ANOMALOUS X-RAY PULSARS AND SOFT GAMMA-RAY REPEATERS  

SciTech Connect (OSTI)

We show that the X-ray outburst light curves of four transient anomalous X-ray pulsars (AXPs) and soft gamma-ray repeaters (SGRs), namely, XTE J1810-197, SGR 0501+4516, SGR 1627-41, and CXOU J164710.2-455216, can be produced by the fallback disk model that was also applied to the outburst light curves of persistent AXPs and SGRs in our earlier work. The model solves the diffusion equation for the relaxation of a disk that has been pushed back by a soft gamma-ray burst. The sets of main disk parameters used for these transient sources are very similar to each other and to those employed in our earlier models of persistent AXPs and SGRs. There is a characteristic difference between the X-ray outburst light curves of transient and persistent sources. This can be explained by the differences in the disk surface density profiles of the transient and persistent sources in quiescence indicated by their quiescent X-ray luminosities. Our results imply that a viscous disk instability operating at a critical temperature in the range of {approx}1300-2800 K is a common property of all fallback disks around AXPs and SGRs. The effect of the instability is more pronounced and starts earlier for the sources with lower quiescent luminosities, which leads to the observable differences in the X-ray enhancement light curves of transient and persistent sources. A single active disk model with the same basic disk parameters can account for the enhancement phases of both transient and persistent AXPs and SGRs. We also present a detailed parameter study to show the effects of disk parameters on the evolution of the X-ray luminosity of AXPs and SGRs in the X-ray enhancement phases.

Cal Latin-Small-Letter-Dotless-I skan, Sirin; Ertan, Uenal [Sabanc Latin-Small-Letter-Dotless-I University, Orhanl Latin-Small-Letter-Dotless-I -Tuzla, Istanbul, 34956 (Turkey)

2012-10-20T23:59:59.000Z

328

X-ray magnetic circular dichroism in (Ge,Mn) compounds: experiments and modeling Samuel Tardif,1, 2,  

E-Print Network [OSTI]

X-ray magnetic circular dichroism in (Ge,Mn) compounds: experiments and modeling Samuel Tardif,1, 2: July 29, 2013) X-ray absorption (XAS) and x-ray magnetic circular dichroism (XMCD) spectra at the L2),6 and x-ray spectroscopy (x-ray absorption spec- troscopy, XAS, and x-ray magnetic circular

329

Crystallization and preliminary X-ray crystallographic study of disproportionating enzyme from potato  

Science Journals Connector (OSTI)

Disproportionating enzyme from potato was crystallized and preliminarily analyzed using X-ray diffraction.

Imamura, K.

2004-12-24T23:59:59.000Z

330

Evolution of Cygnus X-3 through its Radio and X-ray States  

SciTech Connect (OSTI)

Based on X-ray spectra and studies of the long-term correlated behavior between radio and soft X-ray, we present a detailed evolution of Cyg X-3 through its radio and X-ray states. We comment on the nature of the hard X-ray tail and possible Simbol X contribution in constraining the models.

Szostek, A. [Laboratoire d'Astrophysique de Grenoble, CNRS, Universite Joseph Fourier, Grenoble (France); Astronomical Observatory, Jagiellonian University, Krakow (Poland); Zdziarski, A. A. [Centrum Astronomiczne im. M. Kopernika, Warszawa (Poland); McCollough, M. L. [Smithsonian Astrophysical Observatory, Cambridge (United States)

2009-05-11T23:59:59.000Z

331

Determination of the iron-sulfur distances in rubredoxin by x-ray absorption spectroscopy  

Science Journals Connector (OSTI)

...x-ray flux from the synchrotron radiation at the Stanford Synchroton Radiation Project has been used to study the extended x-ray...x-ray flux from the synchrotron radiation at the Stanford Synchroton Radiation Project has been used to study the extended x-ray...

R G Shulman; P Eisenberger; W E Blumberg; N A Stombaugh

1975-01-01T23:59:59.000Z

332

X-ray Diffraction / MSE 603 Spring 2002 Qun Shen / CHESS qs11@cornell.edu  

E-Print Network [OSTI]

X-ray Diffraction / MSE 603 Spring 2002 Qun Shen / CHESS qs11@cornell.edu 1. X-ray production & basic properties ­ common sources for diffraction experiments ­ synchrotron radiation ­ response to x-rays by an electron ­ refraction index ­ total external reflection & evanescent wave, TXRF 2. X-ray scattering basics

Shen, Qun

333

Soft X-Ray Diffraction Microscopy of a Frozen Hydrated Yeast Cell Xiaojing Huang,1  

E-Print Network [OSTI]

Soft X-Ray Diffraction Microscopy of a Frozen Hydrated Yeast Cell Xiaojing Huang,1 Johanna Nelson,1 eukaryotic cell using x-ray diffraction microscopy, or coherent x-ray diffraction imaging. By plunge freezingV x rays were recorded and reconstructed to reveal a budding yeast cell at a resolution better than 25

Mohseni, Hooman

334

X-ray Spectroscopy of O Supergiant Winds: Shock Physics, Clumping, and Mass-Loss Rates  

E-Print Network [OSTI]

X-ray Spectroscopy of O Supergiant Winds: Shock Physics, Clumping, and Mass-Loss Rates David Cohen Li (Swarthmore '16), Kelley Langhans (Swarthmore '16) #12;Talk Outline Context of O star X-ray emission: wind shocks 1. X-ray constraints on the shocked wind plasma 2. X-ray absorption as a mass

Cohen, David

335

X-ray spectral diagnostics of neon photoionization experiments on the Z-machine  

E-Print Network [OSTI]

X-ray spectral diagnostics of neon photoionization experiments on the Z-machine David H. Cohen on an initial spectroscopic study of low-density, x-ray photoionized neon with x-ray spectroscopy plasma, and to explore issues related to the rapid x-ray photoionization of relatively cold, low

Cohen, David

336

X-ray absorption anisotropy for polychromatic illumination--Crystal views from inside  

E-Print Network [OSTI]

X-ray absorption anisotropy for polychromatic illumination--Crystal views from inside P. Korecki a Keywords: X-ray absorption Real-space imaging X-ray holography Electron channeling Electron backscatter of the fine structure in X-ray absorption anisotropy, which results from incident beam diffraction

Korecki, Pawe³

337

X-ray emission from clusters of galaxies Craig L. Sarazin  

E-Print Network [OSTI]

X-ray emission from clusters of galaxies Craig L. Sarazin Department of Astronomy, University show that they are bright x-ray sources, with luminosities of 1043 45 ergs/sec. It is now established the stars in all the galaxies in the cluster. The x-ray spectra of clusters show strong x-ray line emission

Sarazin, Craig

338

X-ray Diffraction Laboratory: Department of Chemistry Texas A & M University  

E-Print Network [OSTI]

X-ray Diffraction Laboratory: Department of Chemistry Texas A & M University Doc. No: SOPUSERFD form that can be accessed by the X-ray diffraction webpage. RESPONSIBILITY: The X-ray Diffraction and suggestions in a timely manner. MATERIALS: · Computer Database · Web interface #12;X-ray Diffraction

Meagher, Mary

339

X-ray four-wave mixing in molecules Satoshi Tanaka  

E-Print Network [OSTI]

X-ray four-wave mixing in molecules Satoshi Tanaka Department of Chemistry, University of Rochester radiation intense light sources have opened up a new era in soft x-ray spectroscopy. The dramatic improvements of spectral resolution in x-ray absorption1,2 and x-ray photoemission spectra3 have revealed

Mukamel, Shaul

340

X-Ray: A Tool for Automatic Measurement of Hardware Parameters  

E-Print Network [OSTI]

X-Ray: A Tool for Automatic Measurement of Hardware Parameters Kamen Yotov, Keshav Pingali, Paul and register tiles. In this paper, we describe X-Ray1 , a system for im- plementing micro-benchmarks to measure. Experimen- tal evaluations of X-Ray on traditional workstations, servers and embedded systems show that X-Ray

Pingali, Keshav K.

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

A low-cost X-ray-transparent experimental cell for synchrotron-based X-ray microtomography studies under geological reservoir conditions  

Science Journals Connector (OSTI)

An X-ray-transparent experimental environment that allows time-resolved studies of porous rocks under geological reservoir conditions using high-energy synchrotron X-ray microtomography is presented.

Fusseis, F.

2013-12-05T23:59:59.000Z

342

Detection limits of high temperature superconducting materials on various substrates by energy dispersive X-ray fluorescence and proton induced X-ray emission methods  

Science Journals Connector (OSTI)

Application of energy dispersive X-ray fluorescence (EDXRF) and proton induced X-ray emission (PIXE) methods has been demonstrated for determining the elemental composition of thin film superconducting materia...

M Lal; H N Bajpai; D Joseph; R K Choudhury

1990-04-01T23:59:59.000Z

343

‘Taking X-ray phase contrast imaging into mainstream applications’ and its satellite workshop ‘Real and reciprocal space X-ray imaging’  

Science Journals Connector (OSTI)

...presented Femtosecond X-ray lasers for imaging atomic structure...which he described X-ray laser-induced electronic ordering...characterization of targets for laser fusion experiments. Krist. Tech...1205396109 ) 20 Talbot, HF . 1836 Facts relating to...

2014-01-01T23:59:59.000Z

344

On the dynamics of the Pomeranian Bight. Hans-Ulrich Lass, Volker Mohrholz and Torsten Seifert  

E-Print Network [OSTI]

between the surface waters of the Arkona Basin and the Pomeranian Bight. It drives a southwardOn the dynamics of the Pomeranian Bight. Hans-Ulrich Lass, Volker Mohrholz and Torsten Seifert obtained from the Pomeranian Bight, on cruises of 2­3 weeks duration together with time-series measurements

Mohrholz, Volker

345

X-ray movies reveal insect flight, muscle motion  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BioCAT BioCAT X-ray movies reveal insect flight, muscle motion Photo credit: Michael Dickinson Watching flies fly may not seem like high-tech science, but for researchers using the Western Hemisphere's most brilliant X-rays, from the Advanced Photon Source located at the U.S. Department of Energy's Argonne National Laboratory, it not only helps explain how insects fly but also may someday aid in understanding human heart function. The researchers, from the Illinois Institute of Technology (IIT), Caltech and the University of Vermont, merged two distinct technologies, intense X-ray beams and electronic flight simulators, to study how insect muscles can generate such extraordinary levels of power. The results are published in the the January 20,. 2005, issue of the journal Nature.

346

X-ray Microscopy and Imaging (XSD-XMI)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Imaging (XMI) Imaging (XMI) About XMI Science and Research Beamlines Highlights Software and Tools Intranet Search APS... Argonne Home > Advanced Photon Source > Contacts FAQs Beamlines News Publications APS Email Portal APS Intranet APS Phonebook APS Quick Links for Users APS Safety and Training Welcome to the X-ray Microscopy and Imaging group (XMI)! X-ray Microscopy and Imaging is part of the X-ray Science Division at the Advanced Photon Source. We develop and support a diverse and multidisciplinary user research program at Sectors 2 and 32 of the APS, with the overall goal to image and study materials structures at spatial and temporal resolutions that are most scientifically relevant to the cutting-edge advances in materials, biological, environmental, and biomedical sciences. To achieve this goal, we actively engage in various research activities including

347

Photon Sciences | Beamlines | XPD: X-ray Powder Diffraction  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

XPD: X-ray Powder Diffraction XPD: X-ray Powder Diffraction Poster | Fact Sheet | Preliminary Design Report Scientific Scope XPD is a tunable facility with the ability to collect diffraction data at high x-ray energies (40keV-80keV), offering rapid acquisition (millisecond) and high angular resolution capabilities on the same instrument. XPD addresses future scientific challenges in, for example, hydrogen storage, CO2 sequestration, advanced structural ceramics, catalysis, and materials processing. Such materials of high technological value often are complex, nanostructured and heterogeneous. The scientific grand challenge is to obtain robust and quantitative (micro)structural information, not only in the ground state at ambient conditions, but also in situ or in operando with varying temperature, pressure, magnetic/electric/stress

348

Workshop on Time Domain Science Using X-ray Techniques  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Time-Resolved Beamlines Time-Resolved Beamlines Advisory Committee Workshop Home Workshop Chairs: Lin Chen (Argonne National Laboratory) Steve Milton (Advanced Photon Source) David Reis (University of Michigan) Linda Young (Argonne National Laboratory) Workshop on Time Domain Science Using X-ray Techniques August 29 September 1, 2004, The Abbey, Fontana, Lake Geneva Area, Wisconsin A workshop on "Time Domain Science Using X-ray Techniques" was held from August 29 September 1, 2004 , welcoming both experts and beginners in the field. This is one of the concurrently held workshops in the series on "Future Scientific Directions for the Advanced Photon Source." The goal of the workshop was to identify future directions in scientific research using time resolved x-ray techniques and to address possiblities to produce ps

349

X-RAY FLUORESCENCE MICROPROBE (XFM) TECHNIQUES AND CAPABILITIES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RAY FLUORESCENCE MICROPROBE (XFM) RAY FLUORESCENCE MICROPROBE (XFM) TECHNIQUES AND CAPABILITIES APPLICATIONS WORLD-LEADING MICROFOCUSED EXAFS SPECTROSCOPY * XFM is an optimized three-pole wiggler beamline for the characterization of materials in an "as-is" state that are chemically heterogeneous at the micrometer scale via synchrotron induced X-ray fluorescence. * XFM includes instrumentation for microbeam X-ray fluorescence (µXRF), diffraction (µXRD) and fluorescence computed microtomography (FCMT) . However, it is optimized to provide users state-of-the-art microfocused Extended X-ray Absorption Fine Structure (µEXAFS) spectroscopy between 4 to 20 keV. * XFM will trade-off beam size and flux for sample configuration flexibility. This includes more readily achievable stability

350

Portable X-Ray, K-Edge Heavy Metal Detector  

SciTech Connect (OSTI)

The X-Ray, K-Edge Heavy Metal Detection System was designed and built by Ames Laboratory and the Center for Nondestructive Evaluation at Iowa State University. The system uses a C-frame inspection head with an X-ray tube mounted on one side of the frame and an imaging unit and a high purity germanium detector on the other side. the inspection head is portable and can be easily positioned around ventilation ducts and pipes up to 36 inches in diameter. Wide angle and narrow beam X-ray shots are used to identify the type of holdup material and the amount of the contaminant. Precise assay data can be obtained within minutes of the interrogation. A profile of the containerized holdup material and a permanent record of the measurement are immediately available.

Fricke, V.

1999-10-25T23:59:59.000Z

351

Fast microtomography using bright monochromatic x-rays  

SciTech Connect (OSTI)

A fast microtomography system for high-resolution high-speed imaging has been developed using bright monochromatic x-rays at the BL29XU beamline of SPring-8. The shortest scan time for microtomography we attained was 0.25 s in 1.25 {mu}m effective pixel size by combining the bright monochromatic x-rays, a fast rotating sample stage, and a high performance x-ray imaging detector. The feasibility of the tomography system was successfully demonstrated by visualization of rising bubbles in a viscous liquid, an interesting issue in multiphase flow physics. This system also provides a high spatial (a measurable feature size of 300 nm) or a very high temporal (9.8 {mu}s) resolution in radiographs.

Jung, J. W.; Lee, J. S.; Park, S. J.; Chang, S.; Pyo, J. [X-ray Imaging Center, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of); Department of Materials Science and Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of); Kwon, N.; Kim, J. [X-ray Imaging Center, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of); School of Interdisciplinary Bioscience and Bioengineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Kohmura, Y.; Nishino, Y.; Yamamoto, M.; Ishikawa, T. [RIKEN/SPring-8, 1-1-1 Kouto, Mikazuki-cho, Sayo-gun, Hyogo 679-5148 (Japan); Je, J. H. [X-ray Imaging Center, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of); Department of Materials Science and Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Pohang 790-784 (Korea, Republic of); School of Interdisciplinary Bioscience and Bioengineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); RIKEN/SPring-8, 1-1-1 Kouto, Mikazuki-cho, Sayo-gun, Hyogo 679-5148 (Japan)

2012-09-15T23:59:59.000Z

352

Movable anode x-ray source with enhanced anode cooling  

DOE Patents [OSTI]

An x-ray source is disclosed having a cathode and a disc-shaped anode with a peripheral surface at constant radius from the anode axis opposed to the cathode. The anode has stub axle sections rotatably carried in heat conducting bearing plates which are mounted by thermoelectric coolers to bellows which normally bias the bearing plates to a retracted position spaced from opposing anode side faces. The bellows cooperate with the x-ray source mounting structure for forming closed passages for heat transport fluid. Flow of such fluid under pressure expands the bellows and brings the bearing plates into heat conducting contact with the anode side faces. A worm gear is mounted on a shaft and engages serrations in the anode periphery for rotating the anode when flow of coolant is terminated between x-ray emission events. 5 figs.

Bird, C.R.; Rockett, P.D.

1987-08-04T23:59:59.000Z

353

Physical origin of X-ray flares following GRBs  

E-Print Network [OSTI]

One of the major achievements of Swift is the discovery of the erratic X-ray flares harboring nearly half of gamma-ray bursts (GRBs), both for long-duration and short-duration categories, and both for traditional hard GRBs and soft X-ray flashes (XRFs). Here I review the arguments in support of the suggestion that they are powered by reactivation of the GRB central engine, and that the emission site is typically ``internal'', i.e. at a distance within the forward shock front. The curvature effect that characterizes the decaying lightcurve slope during the fading phase of the flares provides an important clue. I will then discuss several suggestions to re-start the GRB central engine and comment on how future observations may help to unveil the physical origin of X-ray flares.

Bing Zhang

2006-02-25T23:59:59.000Z

354

Theory of angular dispersive imaging hard x-ray spectrographs  

E-Print Network [OSTI]

A spectrograph is an optical instrument that disperses photons of different energies into distinct directions and space locations, and images photon spectra on a position-sensitive detector. Spectrographs consist of collimating, angular dispersive, and focusing optical elements. Bragg reflecting crystals arranged in an asymmetric scattering geometry are used as the dispersing elements. A ray-transfer matrix technique is applied to propagate x-rays through the optical elements. Several optical designs of hard x-ray spectrographs are proposed and their performance is analyzed. Spectrographs with an energy resolution of 0.1 meV and a spectral window of imaging up to a few tens of meVs are shown to be feasible for inelastic x-ray scattering (IXS) spectroscopy applications. In another example, a spectrograph with a 1-meV spectral resolution and 85-meV spectral window of imaging is considered for Cu K-edge resonant IXS (RIXS).

Shvyd'ko, Yuri

2015-01-01T23:59:59.000Z

355

The Large Observatory For X-ray Timing: LOFT  

E-Print Network [OSTI]

LOFT, the Large Observatory for X-ray Timing, is a new space mission concept devoted to observations of Galactic and extra-Galactic sources in the X-ray domain with the main goals of probing gravity theory in the very strong field environment of black holes and other compact objects, and investigating the state of matter at supra-nuclear densities in neutron stars. The instruments on-board LOFT, the Large area detector and the Wide Field Monitor combine for the first time an unprecedented large effective area (~10 m2 at 8 keV) sensitive to X-ray photons mainly in the 2-30 keV energy range and a spectral resolution approaching that of CCD-based telescopes (down to 200 eV at 6 keV). LOFT is currently competing for a launch of opportunity in 2022 together with the other M3 mission candidates of the ESA Cosmic Vision Program.

Bozzo, E

2013-01-01T23:59:59.000Z

356

Multiple X-ray reflection from ionized slabs  

E-Print Network [OSTI]

Multiple reflection of X-rays may be important when an accretion disc and its hot corona have a complicated geometry, or if returning radiation due to gravitational light bending is important, or in emission from a funnel such as proposed in some gamma-ray burst models. We simulate the effects of multiple reflection by modifying the boundary condition for an X-ray illuminated slab. Multiple reflection makes the soft X-ray spectrum steeper (softer) and strengthens broad emission and absorption features, especially the K-shell features of iron. This may be important in explaining the spectra of sources such as the Narrow-Line Seyfert 1 galaxy 1H0707-495.

R. R. Ross; A. C. Fabian; D. R. Ballantyne

2002-06-11T23:59:59.000Z

357

Explosive hydrogen burning during type I X-ray bursts  

SciTech Connect (OSTI)

Explosive hydrogen burning in type I X-ray bursts (XRBs) is driven by charged particle reactions creating isotopes with masses up to A {approx} 100. Since charged particle reactions in a stellar environment are very temperature sensitive, we use a realistic time-dependent general relativistic and self-consistent model of type I X-ray bursts to provide accurate values of the burst temperatures and densities. This allows a detailed and accurate time-dependent identification of the reaction flow from the surface layers through the convective region and the ignition region to the neutron star ocean. Using this, we determine the relative importance of specific nuclear reactions in the X-ray burst.

Fisker, J L; Schatz, H; Thielemann, F

2007-06-11T23:59:59.000Z

358

High-Energy Diffraction-Enhanced X-ray Imaging  

SciTech Connect (OSTI)

In order to apply the diffraction-enhanced X-ray imaging (DEI) method for much wider variety of samples, we have developed the high-energy DEI system. The energy of X-ray was increased up to 70 keV to achieve high permeability for heavy elements. The diffraction of Si(440) was used to keep large field of view. Demonstrative observation of an electrical cable was performed using the X-ray emitted from the vertical wiggler. The obtained images visualized not only the core and ground wire made of copper but also the isolator and outer jacket made of polymer clearly. The comparison of images obtained by the DEI and the absorption-contrast imaging showed that the sensitivity of DEI is about 10 times higher than that of the absorption method for light elements, and 3 times for heavy elements.

Yoneyama, Akio; Ueda, Kazuhiro [Advanced Research Laboratory, Hitachi Ltd., 2520, Akanuma, Hatoyama, Saitama, 350-0395 (Japan); Takeda, Tohoru [Allied Health Sciences, Kitasato University, Sagamihara, Kanagawa 228-8555 (Japan); Yamazaki, Takanori [Research and Development Laboratory, Hitachi Cable, Ltd., 5-1-1, Hidakacho, Hitachi, Ibaraki, 319-1414 (Japan); Hyodo, Kazuyuki [Institute of Materials Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki, 305-0801 (Japan)

2010-06-23T23:59:59.000Z

359

X-ray Phase Contrast analysis - Digital wavefront development  

SciTech Connect (OSTI)

Optical schemes that enable imaging of the phase shift produced by an object have become popular in the x-ray region, where phase can be the dominant contrast mechanism. The propagation-based technique consists of recording the interference pattern produced by choosing one or several sample-to-detector distances. Pioneering studies, carried out making use of synchrotron radiation, demonstrated that this technique results in a dramatic increase of image contrast and detail visibility, allowing the detection of structures invisible with conventional techniques. An experimental and theoretical study of in-line hard x-ray phase-contrast imaging had been performed. The theoretical description of the technique is based on Fresnel diffraction. As an illustration of the potential of this quantitative imaging technique, high-resolution x-ray phase contrast images of simple objects will be presented.

Idir, Mourad [Metrology Beamline, Synchrotron SOLEIL, Gif-sur-Yvette (France); Potier, Jonathan [Phaseview, Palaiseau (France); Universite Paul Sabatier-Toulouse III, Metrology Beamline, Synchrotron SOLEIL, Gif-sur-Yvette (France); Fricker, Sebastien [Phaseview, Palaiseau (France); Snigirev, Anatoly; Snigireva, Irina [ESRF, Grenoble (France); Modi, M. H. [X-ray Optics Section, Raja Ramanna Centre for Advanced Technology, Indore (India)

2010-06-23T23:59:59.000Z

360

Nondispersive x-ray diagnostics of short lived plasmas  

SciTech Connect (OSTI)

In this NATO Advanced Study Institute, we have discussed in detail the diagnosis of many pulse power machine properties, including their electrical behavior, grounding and shielding, and related data acquisition techniques. The purpose for many of these machines is to create high temperature/high density plasmas and, therefore, the subsequent behavior of these plasmas is of critical concern. The energy density of these plasmas is such that they will naturally radiate in the x-ray regime and thus the diagnosis of their x-ray emission is a crucial measurement of the entire system performance. In this lecture, I describe the general techniques used to perform nondispersive x-ray diagnostics of these short lived plasmas.

Day, R.H.

1983-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Fundamental physics at an X-ray free electron laser  

E-Print Network [OSTI]

X-ray free electron lasers (FELs) have been proposed to be constructed both at SLAC in the form of the so-called Linac Coherent Light Source as well as at DESY, where the so-called XFEL laboratory is part of the design of the electron-positron linear collider TESLA. In addition to the immediate applications in condensed matter physics, chemistry, material science, and structural biology, X-ray FELs may be employed also to study some physics issues of fundamental nature. In this context, one may mention the boiling of the vacuum (Schwinger pair creation in an external field), horizon physics (Unruh effect), and axion production. We review these X-ray FEL opportunities of fundamental physics and discuss the necessary technological improvements in order to achieve these goals.

A. Ringwald

2001-12-19T23:59:59.000Z

362

Experiment Hazard Class 8.3 - X-Ray Generators  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 - X-Ray Generators 3 - X-Ray Generators Applicability This hazard classification applies to all experiments involving the use of X-Ray Generators (other than the APS storage ring). As specified in LMS-PROC-109 a Radiation Generating Device (RGD) must be registered with the Argonne RGD Safety Officer using the ANL-847 form. The RGD will be assigned an inventory number, hazard class, RWP requirement, and inspection and survey frequencies. Experiment Category Experiments the Experiment Hazard Class are always categorized as High Risk. Experiment Hazard Control Verification Statements Engineered Controls - As determined in LMS-PROC-109. Samples chambers and all beam paths are fully enclosed by barriers. Class 2 and higher RGDs require an interlock to fail-safe beam shutter/beam stop or radiation

363

Plasma focus x?ray source for lithography  

Science Journals Connector (OSTI)

A bright and reliable x?ray source for lithography has been developed using plasma focus.Discharge with constant pressure gas one of the features of plasma focus makes the x?ray source system simple and lengthens lifetime. A fine ceramicinsulator made of alumina in place of a conventional Pyrex glass insulator improves system reliability. The system operates for more than 105discharges without maintenance. The lifetime of the system is ten times longer than that of a conventional plasma focusdevice. The resolution of a pattern printed by multishot exposure depends not only on the diameter of pinched plasma but also on the variation of source position. A new spherical electrode surrounding the plasma?focusing space is added to stabilize the location of the spot on the axis by eddy currents which exert the Lorentz force on the plasma. The spot position deviation has become negligibly small as compared with the pinched plasma diameter. The x?ray source size for neon is 1 mm in diameter and 10 mm in length. Consequently 0.4??m fine pattern has been printed with this source. Neon radiates intense x rays in opposite voltage polarity to that of a conventional plasma focus. Polarity inversion enables a very thin beryllium window to be located on the axis with the assistance of magnetic deflector and plasma stop. An x?ray intensity of 5 mJ/cm2/shot 25 cm from the source with an irradiance of 10 mW/cm2 at the 2?Hz repetition rate has been obtained. The plasma focus is a promising x?ray source for lithography from the viewpoint of intensity resolution and lifetime.

Yasuo Kato; Isao Ochiai; Yoshio Watanabe; Seiichi Murayama

1988-01-01T23:59:59.000Z

364

Measurements of the hard-x-ray reflectivity of iridium  

SciTech Connect (OSTI)

In connection with the design of a hard-x-ray telescope for the Constellation X-Ray Observatory we measured the reflectivity of an iridium-coated zerodur substrate as a function of angle at 55, 60, 70, and 80 keV at the National Synchrotron Light Source of Brookhaven National Laboratory. The optical constants were derived from the reflectivity data. The real component of the index of refraction is in excellent agreement with theoretical values at all four energies. However, the imaginary component, which is related to the mass attenuation coefficient, is 50% to 70% larger at 55, 60, and 70 keV than theoretical values.

Romaine, S.; Bruni, R.; Gorenstein, P.; Zhong, Z

2007-01-10T23:59:59.000Z

365

A New Measurement of the Cosmic X-ray Background  

SciTech Connect (OSTI)

I present a new analytical description of the cosmic X-ray background (CXRB) spectrum in the 1.5-200 keV energy band, obtained by combining the new measurement performed by the Swift X-ray telescope (XRT) with the recently published Swift burst alert telescope (BAT) measurement. A study of the cosmic variance in the XRT band (1.5-7 keV) is also presented. I find that the expected cosmic variance (expected from LogN-LogS) scales as {omega}{sup -0.3}(where {omega} is the surveyed area) in very good agreement with XRT data.

Moretti, A. [INAF-Osservatorio Astronomico di Brera v. E. Bianchi 46 23807 Merate (Italy)

2009-05-11T23:59:59.000Z

366

Viscosity in X-ray clusters: Braginskii over 5  

E-Print Network [OSTI]

We argue that it is currently impossible to simulate X-ray clusters using correct equations, because even the MHD description is not applicable. But since fluid simulations actually reproduce observations quite well, one may try to improve the fluid codes by including molecular transport of heat and momentum. We calculate the effective molecular viscosity for the simplest model of magnetic field and obtain 1/5 of the Braginskii value, similar to 1/3 of Spitzer for the heat conduction. This is large enough to noticeably damp the X-ray cluster turbulence.

A. Gruzinov

2006-11-07T23:59:59.000Z

367

X-ray instrumentation for the photon factory  

SciTech Connect (OSTI)

The Photon Factory is one of the world's largest synchroton radiation light sources, the beam lines of which supply intense sources of vacuum UV, soft and hard X-rays. About 30 measuring instruments have been purpose-built, and this book describes the development and construction of the X-ray instrumentation. Given the multifunctional nature of the Photon Factory, it may be expected that the instrumentation serving it fulfills a variety of purposes including: reflection imaging systems; diffraction grating fabrication; monochromators; polarizers; analyzers; detectors; data collection systems; cameras; and goniometers.

Hosoya, S.; Iitaka, Y.; Hashizume, H.

1987-01-01T23:59:59.000Z

368

Confusion of Diffuse Objects in the X-ray Sky  

E-Print Network [OSTI]

Most of the baryons in the present-day universe are thought to reside in intergalactic space at temperatures of 10^5-10^7 K. X-ray emission from these baryons contributes a modest (~10%) fraction of the ~ 1 keV background whose prominence within the large-scale cosmic web depends on the amount of non-gravitational energy injected into intergalactic space by supernovae and AGNs. Here we show that the virialized regions of groups and clusters cover over a third of the sky, creating a source-confusion problem that may hinder X-ray searches for individual intercluster filaments and contaminate observations of distant groups.

G. Mark Voit; August E. Evrard; Greg L. Bryan

2000-12-08T23:59:59.000Z

369

Cooling for a rotating anode X-ray tube  

DOE Patents [OSTI]

A method and apparatus for cooling a rotating anode X-ray tube. An electromagnetic motor is provided to rotate an X-ray anode with cooling passages in the anode. These cooling passages are coupled to a cooling structure located adjacent the electromagnetic motor. A liquid metal fills the passages of the cooling structure and electrical power is provided to the motor to rotate the anode and generate a rotating magnetic field which moves the liquid metal through the cooling passages and cooling structure.

Smither, Robert K. (Hinsdale, IL)

1998-01-01T23:59:59.000Z

370

Optimized Volumetric Scanning for X-Ray Array Sources  

SciTech Connect (OSTI)

Non-destructive evaluation (NDE) is the science and technology of determining non-invasively the internal structure of manufactured parts, objects, and materials. NDE application areas include medicine, industrial manufacturing, military, homeland security, and airport luggage screening. X-ray measurement systems are most widely used because of their ability to image through a wide range of material densities (from human tissue in medical applications to the dense materials of weapon components). Traditional x-ray systems involve a single source and detector system that rotate and/or translate about the object under evaluation. At each angular location, the source projects x-rays through the object. The rays undergo attenuation proportional to the density of the object's constitutive material. The detector records a measure of the attenuation. Mathematical algorithms are used to invert the forward attenuated ray projection process to form images of the object. This is known as computed tomography (CT). In recent years, the single-source x-ray NDE systems have been generalized to arrays of x-ray sources. Array sources permit multiple views of the object with fewer rotations and translations of the source/detector system. The spatially diverse nature of x-ray array sources has the potential of reducing data collection time, reducing imaging artifacts, and increasing the resolution of the resultant images. Most of the existing CT algorithms were not derived from array source models with a spatially diverse set of viewing perspectives. Single-source x-ray CT data collection, processing, and imaging methods and algorithms are not applicable when the source location is expanded from one dimension (a rotating and/or translating point source) to two (a rotating and/or translating array). They must be reformulated. The goal of this project is to determine the applicability of x-ray array sources to problems of interest to LLNL and its customers. It is believed array source data collection will be faster while yielding higher resolution reconstructions with fewer artifacts. There are three tasks in the research: (1) Develop forward array source analytic and computational models; (2) Research and develop array source reconstruction algorithms; and (3) Perform experiments.

Lehman, S K; Foudray, A M; Wang, A; Kallman, J S; Martz, H

2009-09-29T23:59:59.000Z

371

High intensity line source for x-ray spectrometer calibration  

SciTech Connect (OSTI)

A high intensity electron-impact x-ray source using a one-dimensional Pierce lens has been built for the purpose of calibrating a bent crystal x-ray spectrometer. This source focuses up to 100 mA of 20-keV electrons to a line on a liquid-cooled anode. The line (which can serve as a virtual slit for the spectrometer) measures approximately 800 ..mu.. x 2 cm. The source is portable and therefore adaptable to numerous types of spectrometer applications. One particular application, the calibration of a high resolution (r = 10/sup 4/) time-resolved cyrstal spectrometer, will be discussed in detail.

Thoe, R.S.

1986-06-01T23:59:59.000Z

372

High resolution collimator system for X-ray detector  

DOE Patents [OSTI]

High resolution in an X-ray computerized tomography (CT) inspection system is achieved by using a collimator/detector combination to limit the beam width of the X-ray beam incident on a detector element to the desired resolution width. In a detector such as a high pressure Xenon detector array, a narrow tapered collimator is provided above a wide detector element. The collimator slits have any desired width, as small as a few mils at the top, the slit width is easily controlled, and they are fabricated on standard machines. The slit length determines the slice thickness of the CT image.

Eberhard, Jeffrey W. (Schenectady, NY); Cain, Dallas E. (Scotia, NY)

1987-01-01T23:59:59.000Z

373

Method and apparatus for producing sharp chromatic x-ray images of x-ray emitting objects  

SciTech Connect (OSTI)

Method and apparatus for producing sharp, chromatic, magnified images of X-ray emitting objects, are provided. The apparatus, which constitutes an X-ray microscope or telescope, comprises a connected collection of Bragg reflecting planes, comprised of either a bent crystal or a synthetic multilayer structure, disposed on and adjacent to a locus determined by a spherical surface. The individual Bragg planes are spatially oriented to Bragg reflect radiation from the object location toward the image location. This is accomplished by making the Bragg planes spatially coincident with the surfaces of either a nested series of prolate ellipsoids of revolution, or a nested series of spheres. The spacing between the Bragg reflecting planes can be tailored to control the wavelengths and the amount of the X-radiation that is Bragg reflected to form the X-ray image. 7 figs.

Thoe, R.S.

1990-01-09T23:59:59.000Z

374

An experimental measurement of metal multilayer x-ray reflectivity degradation due to intense x-ray flux  

SciTech Connect (OSTI)

The degradation of the x-ray reflection characteristics of metal multilayer Bragg diffractors due to intense x-ray flux was investigated. The Z-pinch plasma produced by PROTO II of Sandia National Laboratories, Albuquerque, New Mexico, was used as the source. The plasma generated total x-ray yields of as much as 40 kJ with up to 15 kJ in the neon hydrogen- and helium-like resonance lines in nominal 20-ns pulses. Molybdenum-carbon, palladium-carbon, and tungsten-carbon metal multilayers were placed at 15 and 150 cm from the plasma center. The multilayers were at nominal angles of 5/sup 0/ and 10/sup 0/ to diffract the neon resonance lines. The time-integrated x-ray reflection of the metal multilayers was monitored by x-ray film. A fluorescer-fiber optic-visible streak camera detector system was then used to monitor the time-resolved x-ray reflection characteristics of 135 A- 2d tungsten-carbon multilayers. A large specular component in the reflectivity prevented determination of the rocking curve of the multilayer. For a neon implosion onto a vanadium-doped polyacrylic acid foam target shot, detailed modeling was attempted. The spectral flux was determined with data from 5 XRD channels and deconvolved using the code SHAZAM. The observed decay in reflectivity was assumed to correspond to the melting of the first tungsten layer. A ''conduction factor'' of 82 was required to manipulate the heat loading of the first tungsten layer such that the time of melting corresponded to the observed decay. The power at destruction was 141 MW/cm/sup 2/ and the integrated energy at destruction was 2.0 J/cm/sup 2/. 82 refs., 66 figs., 10 tabs.

Hockaday, M.Y.P.

1987-06-01T23:59:59.000Z

375

Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources  

SciTech Connect (OSTI)

Purpose: The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammography. However, most of these models cannot be used directly for modeling microfocus x-ray sources due to differences in inherent filtration, energy range and/or anode material. For this reason the authors propose in this work a new model for the simulation of microfocus spectra based on existing models for mammography and radiology, modified to compensate for the effects of inherent filtration and energy range. Methods: The authors used the radiology and mammography versions of an existing empirical model [tungsten anode spectral model interpolating polynomials (TASMIP)] as the basis of the microfocus model. First, the authors estimated the inherent filtration included in the radiology model by comparing the shape of the spectra with spectra from the mammography model. Afterwards, the authors built a unified spectra dataset by combining both models and, finally, they estimated the parameters of the new version of TASMIP for microfocus sources by calibrating against experimental exposure data from a microfocus x-ray source. The model was validated by comparing estimated and experimental exposure and attenuation data for different attenuating materials and x-ray beam peak energy values, using two different x-ray tubes. Results: Inherent filtration for the radiology spectra from TASMIP was found to be equivalent to 1.68 mm Al, as compared to spectra obtained from the mammography model. To match the experimentally measured exposure data the combined dataset required to apply a negative filtration of about 0.21 mm Al and an anode roughness of 0.003 mm W. The validation of the model against real acquired data showed errors in exposure and attenuation in line with those reported for other models for radiology or mammography. Conclusions: A new version of the TASMIP model for the estimation of x-ray spectra in microfocus x-ray sources has been developed and validated experimentally. Similarly to other versions of TASMIP, the estimation of spectra is very simple, involving only the evaluation of polynomial expressions.

Sisniega, A.; Vaquero, J. J., E-mail: juanjose.vaquero@uc3m.es [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid ES28911 (Spain); Instituto de Investigación Sanitaria Gregorio Marañón, Madrid ES28007 (Spain); Desco, M. [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid ES28911 (Spain) [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid ES28911 (Spain); Instituto de Investigación Sanitaria Gregorio Marañón, Madrid ES28007 (Spain); Centro de Investigación Biomédica en Red de Salud Mental (CIBERSAM), Madrid ES28029 (Spain)

2014-01-15T23:59:59.000Z

376

THE X-RAY BINARY POPULATION IN M33. II. X-RAY SPECTRA AND VARIABILITY H.-J. Grimm, J. McDowell, A. Zezas, D.-W. Kim, and G. Fabbiano  

E-Print Network [OSTI]

THE X-RAY BINARY POPULATION IN M33. II. X-RAY SPECTRA AND VARIABILITY H.-J. Grimm, J. McDowell, A the X-ray spectra and X-ray spectral variability of compact X-ray sources for 3 Chandra observations observations shows that X-ray absorption values are consistent with Galactic X-ray binaries and most sources

Kim, Dong-Woo

377

The SIMBOL-X hard X-ray mission  

Science Journals Connector (OSTI)

SIMBOL-X is a hard X-ray mission ... jointly carried out by CNES and ASI. SIMBOL-X makes uses of a long (in ... non focusing techniques used so far. The SIMBOL-X revolutionary instrumental capabilities will allow...

Giovanni Pareschi; Philippe Ferrando

2005-12-01T23:59:59.000Z

378

The SIMBOL-X hard X-ray mission  

Science Journals Connector (OSTI)

SIMBOL-X is a hard X-ray mission ... jointly carried out by CNES and ASI. SIMBOL-X makes uses of a long (in ... non focusing techniques used so far. The SIMBOL-X revolutionary instrumental capabilities will allow...

Giovanni Pareschi; Philippe Ferrando

2006-01-01T23:59:59.000Z

379

Data needs for X-ray astronomy satellites  

SciTech Connect (OSTI)

I review the current status of atomic data for X-ray astronomy satellites. This includes some of the astrophysical issues which can be addressed, current modeling and analysis techniques, computational tools, the limitations imposed by currently available atomic data, and the validity of standard assumptions. I also discuss the future: challenges associated with future missions and goals for atomic data collection.

Kallman, T. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

2013-07-11T23:59:59.000Z

380

THE SWIFT/BAT HARD X-RAY TRANSIENT MONITOR  

SciTech Connect (OSTI)

The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as fine as 64 s. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the flux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public Web site. Between 2005 February 12 and 2013 April 30, 245 sources have been detected in the monitor, 146 of them persistent and 99 detected only in outburst. Among these sources, 17 were previously unknown and were discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and filtering for the BAT transient monitor and review its sensitivity and exposure. We provide a summary of the source detections and classify them according to the variability of their light curves. Finally, we review all new BAT monitor discoveries. For the new sources that are previously unpublished, we present basic data analysis and interpretations.

Krimm, H. A.; Holland, S. T.; Corbet, R. H. D.; Pearlman, A. B.; Baumgartner, W. H.; Cummings, J. R. [Center for Research and Exploration in Space Science and Technology (CRESST) and NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Romano, P. [INAF, Istituto di Astrofisica Spaziale e Fisica Cosmica, Via U. La Malfa 153, I-90146 Palermo (Italy); Kennea, J. A. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Bloom, J. S. [Department of Astronomy, University of California, Berkeley, Berkeley, CA 94720-3411 (United States); Barthelmy, S. D.; Gehrels, N.; Lien, A. Y.; Markwardt, C. B.; Ukwatta, T. N. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Palmer, D. M. [Los Alamos National Laboratory, B244, Los Alamos, NM 87545 (United States); Sakamoto, T. [Department of Physics and Mathematics, College of Science and Engineering, Aoyama Gakuin University, 5-10-1 Fuchinobe, Chuo-ku, Sagamihara-shi, Kanagawa 252-5258 (Japan); Stamatikos, M. [Department of Physics and Center for Cosmology and Astro-Particle Physics, Ohio State University, Columbus, OH 43210 (United States)

2013-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Search for X-ray occultations in active galactic nuclei  

Science Journals Connector (OSTI)

......The simplest and most effective (in terms of source coverage due to the intervening...all the existing XMM observations do not enter in our sample since they last less than...interpretation of HR time variability in terms of X-ray source occultations by BLR-like......

G. Torricelli-Ciamponi; P. Pietrini; G. Risaliti; M. Salvati

2014-01-01T23:59:59.000Z

382

DEDUCING ELECTRON PROPERTIES FROM HARD X-RAY OBSERVATIONS  

E-Print Network [OSTI]

of the accelerated electron distribution. Keywords: Sun: flares; Sun: X-rays; Sun: acceleration; Sun: energetic distribution 31 4.5 Low-energy cutoffs in the electron distribution 32 4.6 Temperature distribution of thermal-ray emission process(es) in question with the electron distribution function, which is in turn a function

Piana, Michele

383

ROSAT X-ray observations of 3CRR radio sources  

Science Journals Connector (OSTI)

......al. 1995). The available X-ray data are unfortunately not good enough to test whether 3C 288 lies in a cooling flow, a suggested...Leahy J. P. , Bridle A. H., Strom R. G.. (1998, Internet WWW page, at URL: http://www:jb:man:ac:uk/atlas......

M. J. Hardcastle; D. M. Worrall

1999-11-11T23:59:59.000Z

384

Soft x-ray laser microscope. Final report  

SciTech Connect (OSTI)

The program consisted of two phases (Phase I and Phase II). The goal of the Phase I (first year program) was to design and construct the Soft X-ray Laser Contact Microscope. Such microscope was constructed and adapted to PPL`s 18.2nm soft X-ray Laser (SXL), which in turn was modified and prepared for microscopy experiments. Investigation of the photoresist response to 18.2nm laser radiation and transmissivity of 0.1m thick silicion-nitride (Si{sub 3}N{sub 4}) windows were important initial works. The goal of the first year of Phase II was to construct X-ray contact microscope in combination with existing optical phase microscope, already used by biologists. In the second year of Phase II study of dehydrated Horeseshoe Crab and Hela cancer cells were performed with COXRALM. Also during Phase II, the Imaging X-Ray Laser Microscope (IXRALM) was designed and constructed. This paper describes the development of each of the microscopes and their application for research.

Suckewer, P.I.

1990-10-01T23:59:59.000Z

385

Radioactivity and X-rays Applications and health effects  

E-Print Network [OSTI]

as the release of radioactivity from reactor accidents and fallout from nuclear explosions in the atmosphereRadioactivity and X-rays Applications and health effects by Thormod Henriksen #12;Preface ­ 7 Chapter 2. What is radioactivity page 8 ­ 27 Chapter 3. Radioactive decay laws page 28 ­ 35

Sahay, Sundeep

386

The Evolution of Coronal X-ray Emission  

E-Print Network [OSTI]

as a hydrogen burning star. Rocks were present in the solar system at 1 Myr, the giant planets formed within 10 flares, coronal mass ejections etc. interact(ed) with planetary systems. The properties of the early Sun out (i.e. photoionisation/photodissociation can change chemistry, X-ray/EUV radiation can heat upper

387

Vanadium-pumped titanium x-ray laser  

DOE Patents [OSTI]

A resonantly photo-pumped x-ray laser is formed of a vanadium and titanium foil combination that is driven by two beams of intense line focused optical laser radiation. Ground state neon-like titanium ions are resonantly photo-pumped by line emission from fluorine-like vanadium ions. 4 figs.

Nilsen, J.

1992-05-26T23:59:59.000Z

388

Vanadium-pumped titanium x-ray laser  

DOE Patents [OSTI]

A resonantly photo-pumped x-ray laser (10) is formed of a vanadium (12) and titanium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state neon-like titanium ions (34) are resonantly photo-pumped by line emission from fluorine-like vanadium ions (32).

Nilsen, Joseph (Livermore, CA)

1992-01-01T23:59:59.000Z

389

Population synthesis for symbiotic X-ray binaries  

Science Journals Connector (OSTI)

......X-ray luminosities (mass-accretion rates...models with a low wind velocity (v w = 1/2v esc...Figure 6 Grey-scale maps of the distributions...period P s versus mass-accretion rate...greatly depends on the wind velocity. NSs in 4U 1954......

G.-L. Lü; C.-H. Zhu; K. A. Postnov; L. R. Yungelson; A. G. Kuranov; N. Wang

2012-08-11T23:59:59.000Z

390

Generating coherent broadband continuum soft-x-ray radiation by  

E-Print Network [OSTI]

Generating coherent broadband continuum soft-x-ray radiation by attosecond ionization gating Thomas as the driver for high-harmonic generation that has a cosine-like electric field stabilized with respect the generation of broadband and tunable attosecond pulses. Instead of fixing the carrier-envelope phase

Neumark, Daniel M.

391

X-ray emission from clusters of galaxies  

SciTech Connect (OSTI)

Some X-ray spectral observations of approximately 30 clusters of galaxies from HEAO-1 are summarized. There exists strong correlations between X-ray luminosity, L(x), and temperature kT in the form L(x)alphaT to the 2.3 power. This result combined with the L(x) central galaxy density relation and the virial theorem indicates that the core radius of the gas should be roughly independent of L(x) or KT and that more luminous clusters have a greater fraction of their virial mass in gas. The poor correlation of KT and optical velocity dispersion seems to indicate that clusters have a variety of equations of state. There is poor agreement between X-ray imaging observations and optical and X-ray spectral measures of the polytropic index. Most clusters show Fe emission lines with a strong indication that they all have roughly 1/2 solar abundance. The evidence for cooling in the cores of several clusters is discussed based on spectral observations with the Einstein solid state spectrometer.

Mushotzky, R.F.

1983-05-01T23:59:59.000Z

392

Observation of correlated X-ray scattering at atomic resolution  

Science Journals Connector (OSTI)

...order, such as proteins in solution...to study such disordered matter. The...X-rays from an ensemble of identical...signal from an ensemble in three dimensions...experiments on disordered ensembles-such as proteins in solution-may...

2014-01-01T23:59:59.000Z

393

Modeling Structural Heterogeneity in Proteins From X-Ray Data  

E-Print Network [OSTI]

Modeling Structural Heterogeneity in Proteins From X-Ray Data Ankur Dhanik1 , Henry van den Bedem2: In a crystallographic experiment, a protein is precipitated to obtain a crystalline sample (crystal) containing many determination and density calculation. The protein conformation is modeled by placing the atoms in 3-D space

Pratt, Vaughan

394

Single atom identification by energy dispersive x-ray spectroscopy  

SciTech Connect (OSTI)

Using aberration-corrected scanning transmission electron microscope and energy dispersive x-ray spectroscopy, single, isolated impurity atoms of silicon and platinum in monolayer and multilayer graphene are identified. Simultaneously acquired electron energy loss spectra confirm the elemental identification. Contamination difficulties are overcome by employing near-UHV sample conditions. Signal intensities agree within a factor of two with standardless estimates.

Lovejoy, T. C.; Dellby, N.; Krivanek, O. L. [Nion, 1102 8th St., Kirkland, Washington 98033 (United States); Ramasse, Q. M. [SuperSTEM Laboratory, STFC Daresbury, Keckwick Lane, Daresbury WA4 4AD (United Kingdom); Falke, M.; Kaeppel, A.; Terborg, R. [Bruker Nano GmbH, Schwarzschildstr. 12, 12489 Berlin (Germany); Zan, R. [School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom)

2012-04-09T23:59:59.000Z

395

Transient x-ray absorption spectroscopy of hydrated halogen atom  

E-Print Network [OSTI]

Time-resolved x-ray absorption spectroscopy has been used to observe the transient species generated by one-photon detachment of an electron from aqueous bromide. The K-edge spectrum of the short-lived Br(0) atom exhibits a resonant 1s-4p transition...

Elles, Christopher G.; Shkrob, Ilya A.; Crowell, Robert A.; Arms, Dohn A.; Landahl, Eric C.

2008-02-11T23:59:59.000Z

396

X-rays at Solid-Liquid Surfaces  

SciTech Connect (OSTI)

Solid-liquid interfaces play an important role in many areas of current and future technologies, and in our biosphere. They play a key role in the development of nanofluidics and nanotribology, which sensitively depend on our knowledge of the microscopic structures and phenomena at the solid-liquid interface. The detailed understanding of how a fluid meets a wall is also a theoretical challenge. In particular, the phenomena at repulsive walls are of interest, since they affect many different phenomena, such as water-repellent surfaces or the role of the hydrophobic interaction in protein folding. Recent x-ray reflectivity studies of various solid-liquid interfaces have disclosed rather intriguiing phenomena, which will be discussed in this lecture: premelting of ice in contact with silica; liquid Pb in contact with Si; water in contact with hydrophobic surfaces. These experiments, carried out with high-energy x-ray microbeams, reveal detailed insight into the liquid density profile closest to the wall. A detailed insight into atomistic phenomena at solid-liquid interfaces is also a prerequisite in the microscopic control of electrochemical reactions at interfaces. Recent x-ray studies show the enormous future potential of such non-destructive analytical tools for the in situ observation of (electro-)chemical surface reactions. This lecture will review recent x-ray experiments on solid-liquid interfaces.

Dosch, Helmut (Max Planck Institute for Metals Research) [Max Planck Institute for Metals Research

2007-05-02T23:59:59.000Z

397

High-resolution imaging with soft x-rays  

Science Journals Connector (OSTI)

...concave surface of the larger mirror, where a second reflection...the surface of the spherical mirrors is the main limitation, and...achievable and will permit a Schwarzschild x-ray microscope to have...be able to test spherical mirrors to within 6 angstroms by next...

AL Robinson

1982-01-08T23:59:59.000Z

398

X-ray Emission from Thunderstorms and Lightning  

ScienceCinema (OSTI)

How lightning is initiated in the relatively low electric fields inside thunderclouds and how it can then propagate for tens of kilometers through virgin air are two of the great unsolved problems in the atmospheric sciences.  Until very recently it was believed that lightning was entirely a conventional discharge, involving only low-energy (a few eV) electrons.  This picture changed completely a few years ago with the discovery of intense x-ray emission from both natural cloud-to-ground lightning and rocket-triggered lightning.  This energetic emission cannot be produced by a conventional discharge, and so the presence of x-rays strongly implies that runaway breakdown plays a role in lightning processes.  During runaway breakdown, electrons are accelerated through air to nearly the speed of light by strong electric fields.  These runaway electrons then emit bremsstrahlung x-rays and gamma-rays during collisions with air.  Indeed, the x-ray and gamma-ray emission produced by runaway breakdown near the tops of thunderstorms is bright enough to be seen from outer space, 600 km away.  As a result, the physics used for decades to describe thunderstorm electrification and lightning discharges is incomplete and needs to be revisited. 

Joseph Dwyer

2010-01-08T23:59:59.000Z

399

X-ray ferromagnetic resonance spectroscopy and S. Rusponi  

E-Print Network [OSTI]

-coupled multilayers,1,2,11,12 as well as current-induced magnetization excitations in spin-valve structures.13,14 Very at GHz frequencies. XMCD is defined as the dependence of the x-ray absorp- tion coefficient

Brune, Harald

400

Double K-Vacancy Production by X-Ray Photoionization  

E-Print Network [OSTI]

Double K-Vacancy Production by X-Ray Photoionization S. H. Southworth£ , R. W. Dunford£ , E. P Photon Source. Double K-vacancy production in Ne was observed by recording the KK-KLL Auger. For Mo, double K-vacancy production was observed by recording the K fluorescence hypersatellite

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Vacuum breakdown mechanisms, and X-ray pulses in accelerators  

Science Journals Connector (OSTI)

During the conditioning of evacuated accelerator tubes, groups of discrete X-ray signals with apparent energies of greater than 300 keV are observed. A mechanism to explain the X-ray emission is proposed in terms of a series of transient vacuum arc discharges. A review is given of vacuum breakdown mechanisms, and of the most likely processes occurring in accelerator tubes during the conditioning process. In the case of the vacuum accelerator tube, there is initially no gaseous medium, but the applied voltage of 30 kV between the tube electrodes is sufficient to lead to the formation of a vacuum arc if there are fine whiskers, impurities, or accelerated dust particles present. Such a vacuum discharge will have a very short life (?1 ?s), as the current of the arc will cause the collapse of the electrode voltage which is maintained by a small current through 600 M? resistors. During the discharge, electrons will escape into the accelerator tube, and fall through several sections to be finally arrested, producing the discrete X-ray signals. The vacuum arc will release charged molten droplets of anode material into the high-field region; after some delay, these droplets will trigger further arcs in different sections of the tube. The triggered arcs will be at the inner edges of the electrode where the droplets hit the electrode, and where electrons are most readily released into the accelerator tube. Thus a whole series of high energy X-ray signals are observed.

R Morrow; D.C Weisser

1996-01-01T23:59:59.000Z

402

Beyond 3-D X-ray Imaging: Methodology Development and Applications in  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Beyond 3-D X-ray Imaging: Methodology Development and Applications in Beyond 3-D X-ray Imaging: Methodology Development and Applications in Material Science Thursday, September 6, 2012 - 10:45am SLAC, Bldg. 137, Room 226 Yijin Liu Seminar There was a revolutionary development of X-ray imaging over the past few decades. The most substantial advancements in this field are closely related to the availability of the new generation of X-ray sources and the advanced X-ray optics. The advanced X-ray Optics along with novel methodology has made it possible to extract information that is related to different interactions between the X-rays and the specimen at very fine spatial resolution. The energy tunability of the X-rays has made it possible to combine the energy scan with imaging technique. And the brilliance of the X-ray source has made it practical for many sophisticated

403

Models for X-Ray Emission from Isolated Pulsars  

E-Print Network [OSTI]

A model is proposed for the observed combination of power-law and thermal emission of keV X-rays from rotationally powered pulsars. For gamma-ray pulsars with accelerators very many stellar radii above the neutron star surface, 100 MeV curvature gamma-rays from $e^{-}$ or $e^{+}$ flowing starward out of such accelerators are converted to electron-positron pairs on closed field lines all around the star. These pairs strongly affect X-ray emission from near the star in two ways. (1) The pairs are a source of synchrotron emission immediately following their creation in regions where $B \\sim 10^{10}$ G. This emission, in the photon energy range 0.1 keV $\\lesssim E_{X} \\lesssim$ 5 MeV, has a power-law spectrum with energy index 0.5 and X-ray luminosity that depends on the backflow current, and is typically $\\sim 10^{33}$ \\lum. (2) The pairs ultimately form a cyclotron resonance ``blanket'' surrounding the star except for two holes along the open field line bundles which pass through it. In such a blanket the gravitational pull on electron-positron pairs toward the star is balanced by the hugely amplified push of outflowing surface emitted X-rays wherever cyclotron resonance occurs. Because of it the neutron star is surrounded by a leaky ``hohlraum'' of hot blackbody radiation with two small holes, which prevents direct X-ray observation of a heated polar cap of a gamma-ray pulsar. Weakly spin-modulated radiation from the blanket together with more strongly spin-modulated radiation from the holes through it would then dominate observed low energy (0.1--10 keV) emission. For non-gamma-ray pulsars, in which no such accelerators with their accompanying extreme relativistic backflow toward the star are ...

F. Y. -H. Wang; M. Ruderman; J. P. Halpern; T. Zhu

1997-11-24T23:59:59.000Z

404

Time dependence of X-ray polarizability of a crystal induced by an intense femtosecond X-ray pulse  

Science Journals Connector (OSTI)

The time evolution of the electron density and the resulting time dependence of the X-ray polarizability of a crystal irradiated by highly intense XFEL femtosecond pulses is investigated theoretically. Rate equations for bound electrons and the Boltzmann equation for the unbound electron gas are used in calculations.

Leonov, A.

2014-10-23T23:59:59.000Z

405

Line X-ray emission from Al targets irradiated by high-intensity, variable-length laser pulses  

E-Print Network [OSTI]

Line X-ray emission from Al targets irradiated by high-intensity, variable-length laser pulses J; the scaling rules for the conversion efficiency of the laser radiation into the line X-ray emission are discussed. Keywords: Laser-produced plasma; Line X-ray emission; X-ray sources; X-ray spectroscopy 1

Limpouch, Jiri

406

Sub-Picosecond X-Ray Pulses Workshop  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

International Workshop on the Interactions of Intense Sub-Picosecond X-Ray International Workshop on the Interactions of Intense Sub-Picosecond X-Ray Pulses with Matter (SLAC, January 23-24, 1997) During the last five years studies have been conducted at the Stanford Linear Accelerator Center (SLAC) and the Deutsches Elektronen-Synchrotron (DESY) in Hamburg concerning the feasibility of driving an Angstrom-wavelength Free-Electron Laser (FEL) with a high energy rf linac. Recent promising advances in linac, rf gun, and insertion device technologies make it seem likely that such a device can be constructed. The output radiation predicted for this type of source will be characterized by full transverse coherence, extreme pulse brevity (~50-100 fs), high peak power (10-100 GW), and very high unfocused peak power density (0.4-4.1013

407

X-ray Holograms Expose Secret Magnetism | Advanced Photon Source  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

How Dissolved Metal Ions Interact in Solution How Dissolved Metal Ions Interact in Solution One Giant Leap for Radiation Biology? What's in the Cage Matters in Iron Antimonide Thermoelectric Materials Novel Experiments on Cement Yield Concrete Results Watching a Glycine Riboswitch "Switch" Science Highlights Archives: 2013 | 2012 | 2011 | 2010 2009 | 2008 | 2007 | 2006 2005 | 2004 | 2003 | 2002 2001 | 2000 | 1998 | Subscribe to APS Science Highlights rss feed X-ray Holograms Expose Secret Magnetism MAY 11, 2007 Bookmark and Share By observing changes in coherent x-ray speckle pattern, such as the one shown above, researchers are able for the first time to investigate nanoscale dynamics of antiferromagnetic domain walls, and observe a cross over from classical to quantum behavior. (Credit: O. Shpyrko)

408

Materials Analysis Using New X-ray Microbeams  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Materials Analysis Using New X-ray Microbeams Materials Analysis Using New X-ray Microbeams Materials ranging from massive steel girders to the microscopic aluminum wires in computer chips are made of grains - tiny crystals with diameters measured in millionths of a meter (microns). If scientists could "see" these individual grains, they could determine their orientation, as well as the effects of stress and chemical activity on them. They might also be able to determine how best to jam more circuits together in microelectronic components, making them smaller and faster, so computers could perform complex functions - such as speech recognition - more quickly. They could also find out to what extent grains of a superconducting material mimic the alignment of the substrate on which the material is grown; discovery of

409

Application of X-ray synchrotron microscopy instrumentation in biology  

SciTech Connect (OSTI)

X-ray micro-fluorescence imaging technique has been used as a significant tool in order to investigate minerals contents in some kinds of materials. The aim of this study was to evaluate the elemental distribution of calcium and zinc in bone substitute materials (nano-hydroxyapatite spheres) and cortical bones through X-Ray Micro-fluorescence analysis with the increment of Synchrotron Radiation in order to evaluate the characteristics of the newly formed bone and its interface, the preexisting bone and biomaterials by the arrangement of collagen fibers and its birefringence. The elemental mapping was carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo, Brazil working at D09-XRF beam line. Based on this study, the results suggest that hydroxyapatite-based biomaterials are biocompatible, promote osteo-conduction and favored bone repair. (authors)

Gasperini, F. M. [Medical Science Program, Fluminense Federal Univ., Niteroi (Brazil); Pereira, G. R. [Dept. of Metallurgical and Materials Engineering, Federal Univ. of Rio de Janeiro (Brazil); Granjeiro, J. M. [Molecular and Cell Biology Dept., Fluminense Federal Univ., Niteroi, Rio de Janeiro (Brazil); Calasans-Maia, M. D. [Oral Surgery Dept., Fluminense Federal Univ., Niteroi, Rio de Janeiro (Brazil); Rossi, A. M. [Biomaterials Laboratory, Brazilian Center of Physics Research, Rio de Janeiro (Brazil); Perez, C. A. [Brazilian Synchrotron Laboratory, Campinas, Sao Paulo (Brazil); Lopes, R. T.; Lima, I. [Nuclear Engineering Laboratory, Federal Univ. of Rio de Janeiro (Brazil)

2011-07-01T23:59:59.000Z

410

An X-ray Polarimeter for Constellation-X  

E-Print Network [OSTI]

Polarimetry remains a largely unexploited technique in observational X-ray astronomy which could provide insight in the study of the strong gravity and magnetic fields at the core of the Constellation-X observational program. Adding a polarization capability to the Constellation-X instrumentation would be immensely powerful. It would make Constellation the first space observatory to simultaneously measure all astrophysically relevant parameters of source X-ray photons; their position (imaging), energy (spectroscopy), arrival time (timing), and polarization. Astrophysical polarimetry requires sensitive well-calibrated instruments. Many exciting objects are extra-galactic (i.e. faint) and may have small polarization. Recent advances in efficiency and bandpass make it attractive to consider a polarimetry Science Enhancement Package for the Constellation-X mission.

Jahoda, K; Deines-Jones, P; Hill, J E; Kallman, T; Strohmayer, T E; Swank, J H

2007-01-01T23:59:59.000Z

411

An X-ray Polarimeter for Constellation-X  

E-Print Network [OSTI]

Polarimetry remains a largely unexploited technique in observational X-ray astronomy which could provide insight in the study of the strong gravity and magnetic fields at the core of the Constellation-X observational program. Adding a polarization capability to the Constellation-X instrumentation would be immensely powerful. It would make Constellation the first space observatory to simultaneously measure all astrophysically relevant parameters of source X-ray photons; their position (imaging), energy (spectroscopy), arrival time (timing), and polarization. Astrophysical polarimetry requires sensitive well-calibrated instruments. Many exciting objects are extra-galactic (i.e. faint) and may have small polarization. Recent advances in efficiency and bandpass make it attractive to consider a polarimetry Science Enhancement Package for the Constellation-X mission.

K. Jahoda; K. Black; P. Deines-Jones; J. E. Hill; T. Kallman; T. Strohmayer; J. H. Swank

2007-01-04T23:59:59.000Z

412

Dense Plasma X-ray Scattering: Methods and Applications  

SciTech Connect (OSTI)

We have developed accurate x-ray scattering techniques to measure the physical properties of dense plasmas. Temperature and density are inferred from inelastic x-ray scattering data whose interpretation is model-independent for low to moderately coupled systems. Specifically, the spectral shape of the non-collective Compton scattering spectrum directly reflects the electron velocity distribution. In partially Fermi degenerate systems that have been investigated experimentally in laser shock-compressed beryllium, the Compton scattering spectrum provides the Fermi energy and hence the electron density. We show that forward scattering spectra that observe collective plasmon oscillations yield densities in agreement with Compton scattering. In addition, electron temperatures inferred from the dispersion of the plasmon feature are consistent with the ion temperature sensitive elastic scattering feature. Hence, theoretical models of the static ion-ion structure factor and consequently the equation of state of dense matter can be directly tested.

Glenzer, S H; Lee, H J; Davis, P; Doppner, T; Falcone, R W; Fortmann, C; Hammel, B A; Kritcher, A L; Landen, O L; Lee, R W; Munro, D H; Redmer, R; Weber, S

2009-08-19T23:59:59.000Z

413

A compact x-ray free electron laser  

SciTech Connect (OSTI)

We present a design concept and simulation of the performance of a compact x-ray, free electron laser driven by ultra-high gradient rf-linacs. The accelerator design is based on recent advances in high gradient technology by a LLNL/SLAC/LBL collaboration and on the development of bright, high current electron sources by BNL and LANL. The GeV electron beams generated with such accelerators can be converted to soft x-rays in the range from 2--10 nm by passage through short period, high field strength wigglers as are being designed at Rocketdyne Linear light sources of this type can produce trains of picosecond (or shorter) pulses of extremely high spectral brilliance suitablee for flash holography of biological specimens in vivo and for studies of fast chemical reactions. 12 refs., 8 figs., 4 tabs.

Barletta, W.A. (California Univ., Los Angeles, CA (USA). Center for Advanced Accelerators Physics Lawrence Livermore National Lab., CA (USA)); Atac, M.; Cline, D.B.; Kolonko, J. (California Univ., Los Angeles, CA (USA). Center for Advanced Accelerators Physics); Bhowmik, A.; Bobbs, B.; Cover, R.A.; Dixon, F.P.; Rakowsky, G. (Rockwell International Corp., Canoga Park, CA (USA). Rocketdyne Div.); Gallardo

1988-01-01T23:59:59.000Z

414

A comprehensive range of X-ray ionized reflection models  

E-Print Network [OSTI]

X-ray ionized reflection occurs when a surface is irradiated with X-rays so intense that its ionization state is determined by the ionization parameter xi propto F/n, where F is the incident flux and n the gas density. It occurs in accretion, onto compact objects including black holes in both active galaxies and stellar-mass binaries, and possibly in gamma-ray bursts. Computation of model reflection spectra is often time-consuming. Here we present the results from a comprehensive grid of models computed with our code, which has now been extended to include what we consider to be all energetically-important ionization states and transitions. This grid is being made available as an ionized-reflection model, REFLION, for XSPEC.

R. R. Ross; A. C. Fabian

2005-01-07T23:59:59.000Z

415

Water Window Ptychographic Imaging with Characterized Coherent X-rays  

E-Print Network [OSTI]

We report on a ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at $500~\\mathrm{eV}$. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of the PETRA III synchrotron radiation source. We measured the beam coherence with the newly developed non-redundant array method. A pinhole $2.6~\\mathrm{\\mu m}$ in size selected the coherent part of the beam and was used for ptychographic measurements of a lithographically manufactured test sample and fossil diatom. The achieved resolution was $53~\\mathrm{nm}$ for the test sample and only limited by the size of the detector. The diatom was imaged at a resolution better than $90~\\mathrm{nm}$.

Rose, Max; Dzhigaev, Dmitry; Gorobtsov, Oleg; Senkbeil, Tobias; von Gundlach, Andreas; Gorniak, Thomas; Shabalin, Anatoly; Viefhaus, Jens; Rosenhahn, Axel; Vartanyants, Ivan

2015-01-01T23:59:59.000Z

416

New Developments in Femtosecond Soft X-ray Spectroscopy  

SciTech Connect (OSTI)

Recent instrumentation developments in X-ray spectroscopy for ultra-fast time-resolved measurements with soft X-rays done in HZB Berlin during the last years are described. The significant performance improvements achieved this way are based on Fresnel diffraction from structures being fabricated on a surface of a total externally reflecting mirror. The first type of this spectrometer, an off-axis reflection zone plate, has been implemented at the BESSY Femtoslicing setup and shows on the order of 20 times higher flux in the focal plane compared to the classical grating monochromator beamline. It has proven to serve very precise experiments with a time resolution down to 100 fs on magnetic materials after optical laser pulse excitation.

Erko, A.; Firsov, A.; Holldack, K. [Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Elektronenspeicherring BESSY II, Albert Einstein str.15, Berlin (Germany)

2010-06-23T23:59:59.000Z

417

Background-reducing X-ray multilayer mirror  

DOE Patents [OSTI]

Background-reducing x-ray multilayer mirror. A multiple-layer "wavetrap" deposited over the surface of a layered, synthetic-microstructure soft x-ray mirror optimized for reflectivity at chosen wavelengths is disclosed for reducing the reflectivity of undesired, longer wavelength incident radiation incident thereon. In three separate mirror designs employing an alternating molybdenum and silicon layered, mirrored structure overlaid by two layers of a molybdenum/silicon pair anti-reflection coating, reflectivities of near normal incidence 133, 171, and 186 .ANG. wavelengths have been optimized, while that at 304 .ANG. has been minimized. The optimization process involves the choice of materials, the composition of the layer/pairs as well as the number thereof, and the distance therebetween for the mirror, and the simultaneous choice of materials, the composition of the layer/pairs, and their number and distance for the "wavetrap."

Bloch, Jeffrey J. (Los Alamos, NM); Roussel-Dupre', Diane (Los Alamos, NM); Smith, Barham W. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

418

Micro-array collimators for X-rays and neutrons  

SciTech Connect (OSTI)

The authors describe the fabrication techniques of novel, compact optical elements for collimating and/or focusing beams of X-rays or thermal neutrons. These optical elements are solid composite arrays consisting of regular stacks of alternating micro-foils, analogous in action to Soller slit collimators, but up to three orders of magnitude smaller. The arrays are made of alternating metals with suitable refractive indices for reflection and/or absorption of the specific radiation. In one implementation, the arrays are made of stacked micro-foils of transmissive elements (Al, Cu) coated and/or electroplated with absorbing elements (Gd, Cd), which are repeatedly rolled or drawn and restacked to achieve the required collimation parameters. The authors present results of these collimators using both X-rays and neutrons. The performance of the collimating element is limited only by the choice of micro-foil materials and the uniformity of their interfaces.

Cimmino, A.; Allman, B.E.; Klein, A.G. [Univ. of Melbourne, Parkville (Australia). School of Physics; Hamilton, W.A. [Oak Ridge National Lab., TN (United States). Solid State Div.; Anderson, I.S.; Hamelin, B.; Joeghoej, P. [Inst. Laue-Langevin, Grenoble (France); Bastie, P. [Univ. Joseph Fourier-Grenoble, Saint-Martin-d`Heres (France). Lab. de Spectrometrie Physique

1998-08-01T23:59:59.000Z

419

Fiber fed x-ray/gamma ray imaging apparatus  

DOE Patents [OSTI]

X-ray/gamma ray imaging apparatus is disclosed for detecting the position, energy, and intensity of x-ray/gamma ray radiation comprising scintillation means disposed in the path of such radiation and capable of generating photons in response to such radiation; first photodetection means optically bonded to the scintillation means and capable of generating an electrical signal indicative of the intensity, and energy of the radiation detected by the scintillation means; second photodetection means capable of generating an electrical signal indicative of the position of the radiation in the radiation pattern; and means for optically coupling the scintillation means to the second photodetection means. The photodetection means are electrically connected to control and storage means which may also be used to screen out noise by rejecting a signal from one photodetection means not synchronized to a signal from the other photodetection means; and also to screen out signals from scattered radiation.

Hailey, Charles J. (San Francisco, CA); Ziock, Klaus-Peter (Livermore, CA)

1992-01-01T23:59:59.000Z

420

Soft X-ray properties of Ultraluminous IRAS Galaxies  

E-Print Network [OSTI]

A sample of 323 Ultraluminous IRAS galaxies (ULIRGs) has been correlated with the ROSAT All-Sky Survey and ROSAT public pointed observations. 22 objects are detected in ROSAT survey observations, and 6 ULIRGs are detected in addition in ROSAT public pointed observations. The detection is based on a visual inspection of the X-ray contour maps overlaid on optical images of ULIRGs taken from the Digitized Sky Survey. Simple power law fits were used to compute the absorption-corrected fluxes of the ROSAT detected ULIRGs. The ratio of the soft X-ray flux to the far-infrared luminosity is used to estimate the contribution from starburst and AGN emitting processes. These results are compared with the ISO SWS ULIRG diagnostic diagram.

Th. Boller

1999-04-15T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Rotational Doppler effect in x-ray photoionization  

SciTech Connect (OSTI)

The energy of the photoelectron experiences a red or blue Doppler shift when the molecule recedes from the detector or approaches him. This results in a broadening of the photoelectron line due to the translational thermal motion. However, the molecules also have rotational degrees of freedom and we show that the translational Doppler effect has its rotational counterpart. This rotational Doppler effect leads to an additional broadening of the spectral line of the same magnitude as the Doppler broadening caused by translational thermal motion. The rotational Doppler broadening as well as the rotational recoil broadening is sensitive to the molecular orbital from which the photoelectron is ejected. This broadening should be taken into account in analysis of x-ray photoemission spectra of super-high resolution and it can be directly observed using x-ray pump-probe spectroscopy.

Sun Yuping; Wang Chuankui [College of Physics and Electronics, Shandong Normal University, 250014 Jinan (China); Theoretical Chemistry, Roslagstullsbacken 15, Royal Institute of Technology, S-106 91 Stockholm (Sweden); Gel'mukhanov, Faris [Theoretical Chemistry, Roslagstullsbacken 15, Royal Institute of Technology, S-106 91 Stockholm (Sweden)

2010-11-15T23:59:59.000Z

422

Rotational Doppler effect in x-ray photoionization  

Science Journals Connector (OSTI)

The energy of the photoelectron experiences a red or blue Doppler shift when the molecule recedes from the detector or approaches him. This results in a broadening of the photoelectron line due to the translational thermal motion. However, the molecules also have rotational degrees of freedom and we show that the translational Doppler effect has its rotational counterpart. This rotational Doppler effect leads to an additional broadening of the spectral line of the same magnitude as the Doppler broadening caused by translational thermal motion. The rotational Doppler broadening as well as the rotational recoil broadening is sensitive to the molecular orbital from which the photoelectron is ejected. This broadening should be taken into account in analysis of x-ray photoemission spectra of super-high resolution and it can be directly observed using x-ray pump-probe spectroscopy.

Yu-Ping Sun; Chuan-Kui Wang; Faris Gel’mukhanov

2010-11-10T23:59:59.000Z

423

X-ray mask and method for providing same  

DOE Patents [OSTI]

The present invention describes a method for fabricating an x-ray mask tool which can achieve pattern features having lateral dimension of less than 1 micron. The process uses a thin photoresist and a standard lithographic mask to transfer an trace image pattern in the surface of a silicon wafer by exposing and developing the resist. The exposed portion of the silicon substrate is then anisotropically etched to provide an etched image of the trace image pattern consisting of a series of channels in the silicon having a high depth-to-width aspect ratio. These channels are then filled by depositing a metal such as gold to provide an inverse image of the trace image and thereby providing a robust x-ray mask tool.

Morales, Alfredo M. (Pleasanton, CA); Skala, Dawn M. (Fremont, CA)

2004-09-28T23:59:59.000Z

424

A compact x-ray free electron laser  

SciTech Connect (OSTI)

We present a design concept and simulation of the performance of a compact x-ray, free electron laser driven by ultra-high gradient rf-linacs. The accelerator design is based on recent advances in high gradient technology by a LLNL/SLAC/LBL collaboration and on the development of bright, high current electron sources by BNL and LANL. The GeV electron beams generated with such accelerators can be concerted to soft x-rays in the range from 2--10 nm by passage through short period, high fields strength wigglers as are being designed at Rocketdyne. Linear light sources of this type can produce trains of picosecond (or shorter) pulses of extremely high spectral brilliance suitable for flash holography of biological specimens in vivo and for studies of fast chemical reactions. 12 refs., 8 figs., 4 tabs.

Barletta, W.; Attac, M.; Cline, D.B.; Kolonko, J.; Wang, X.; Bhowmik, A.; Bobbs, B.; Cover, R.A.; Dixon, F.P.; Rakowsky, G.; Gallardo, J.; Pellegrini, C.; Westenskow, G.

1988-09-09T23:59:59.000Z

425

Potential of a beryllium x-ray lens  

SciTech Connect (OSTI)

The use of refractive lenses for focusing x-ray beams has been the subject of publications since the early 1980s. Detailed calculations have been made for different shapes for the refractive lens: cylindrical, spherical, parabolic, and for a Fresnel-type refractive lens. The main drawback to the use of a single refractive lens to focus x-rays is that the index of refraction (n = 1 {minus} {delta}) is very close to 1, which results in a lens with a very long focal length. Recently Snigerov and others have suggested and experimentally demonstrated, using cylindrical-shaped lenses, that this problem of long focal lengths can be overcome by using many lenses in series. Each lens refracts the photon through a small angle, but the sum of these sequential changes in direction can be moderately larger. This increase in effective refraction angle reduces the focal length of the lens to a few meters or less and makes the multi-element lens a much more useful instrument for focusing x-rays. This paper, annualizes the expected performance of a lens consisting of a series of aligned hollow spheres in a beryllium substrate. The use of hollow spheres rather than hollow cylinders produces focusing of the x rays into a small focal spot in contrast to the single-directional focusing of the hollow cylinders, which produces a line focus. Two multi-element lenses have been constructed: one with 20 1-mm-diameter hollow spheres in an aluminum substrate, and one with 50 hollow spheres, 1 mm in diameter, in a beryllium substrate. Some construction details and calculations of the expected performance, are given for these two multi-element lenses.

Smither, R.K.; Khounsary, A.M.; Xu, S. [Argonne National Lab., IL (United States). Advanced Photon Source

1997-09-01T23:59:59.000Z

426

Diffuse scattering of hard x rays from rough surfaces  

Science Journals Connector (OSTI)

The diffuse scattering of hard x rays from rough solid surfaces has been measured and described quantitatively in terms of an improved distorted-wave Born approximation. The rough surface is characterized by the rms roughness ?, the height-height correlation length ?, and the roughness exponent h. The value for ? is in excellent agreement with that deduced from reflectivity. The significance of the parameters ?, ?, and h is tested by comparison with the results obtained from scanning force mircoscopy.

Wolfgang Weber and Bruno Lengeler

1992-09-15T23:59:59.000Z

427

The Large Scale X-ray Emission from M87  

E-Print Network [OSTI]

We describe asymmetrical features in a long exposure X-ray map of M87 made with the ROSAT High Resolution Imager (HRI). A bright triangular region is marked by a linear `spur' along one edge. The structure of this spur suggests an interpretation of a tangential view of a shock front 18 kpc long. None of the brighter features are spatially coincident with radio or optical structures so we concur with earlier investigators that most of the emission arises from thermal processes.

D. E. Harris; J. A. Biretta; W. Junor

1998-04-20T23:59:59.000Z

428

X-ray diffraction data for graphite to 20 GPa  

Science Journals Connector (OSTI)

X-ray diffraction data have been obtained on polycrystalline graphite at pressures up to 20 GPa. A phase transition is observed at ?11 GPa, as evidenced by softening in the interlayer spacing and the observation of new diffraction lines. Below this pressure the variation of the lattice parameters a and c are compared with elastic stiffnesses obtained from ultrasonic measurements. A new value for C13 is proposed. The variation c(P) is compared to the recently proposed universal isotherm equation.

You Xiang Zhao and Ian L. Spain

1989-07-15T23:59:59.000Z

429

Stratigraphic correlation with X-ray powder patterns  

E-Print Network [OSTI]

of certain metallic trace elements, notably magnesium, iron, aluminum, and strontium, and on this basis were able to pick out sones within a thick limestone section which could not be difi'erentiated by ord1nary methods. As an alternative or ad...STRATIGRAPHIC CORRELATION MITH X-RAY PONDER PATTERNS John B. Singletary A Thesis Submitted to the Graduate School Agricultural and Mechanical College of Texas in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE MA...

Singletary, John B

2012-06-07T23:59:59.000Z

430

The Soft X-ray Polarimeter and Applications at BSRF  

SciTech Connect (OSTI)

A novel compact polarimeter for the use in soft x-ray region having high-precision eight-axis automatically driven and two-axis manually driven equipped with multilayer polarizers was developed at the Beijing Synchrotron Radiation Facility (BSRF). The polarimeter was designed to utilize reflection and transmission geometry. Four operational modes have been designed and carried out with the polarimeter. Some experiments have been performed by using this polarimeter with various modes.

Cui Mingqi; Sun Lijuan; Zhu, Jie; Chen Kai; Yan Fen; Zheng Lei; Zhao Yidong [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049 (China); Wang Zhanshan; Zhu Jingtao [Department of Physics, Tongji University, Shanghai, 200092 (China); Xue Song [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, 201204 (China)

2010-06-23T23:59:59.000Z

431

Generating X-ray lines from annihilating dark matter  

E-Print Network [OSTI]

We propose different scenarios where a keV dark matter annihilates to produce a monochromatic signal. The process is generated through the exchange of a light scalar of mass of order 300 keV - 50 MeV coupling to photon through loops or higher dimensional operators. For natural values of the couplings and scales, the model can generate a gamma-ray line which can fit with the recently identified 3.5 keV X-ray line.

Emilian Dudas; Lucien Heurtier; Yann Mambrini

2014-05-08T23:59:59.000Z

432

Advanced Research in Diesel Fuel Sprays Using X-rays from the...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Research in Diesel Fuel Sprays Using X-rays from the Advanced Photon Source Advanced Research in Diesel Fuel Sprays Using X-rays from the Advanced Photon Source 2003 DEER...

433

E-Print Network 3.0 - acute x-ray exposure Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

late effects of acute ionizing radiation exposures in atomic bomb survivors" initiated October 2009... X-ray Yes Yes No No Retesting required 2 X-ray Yes Yes No No Retesting...

434

E-Print Network 3.0 - accurate x-ray scattering Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

RMS. Figure 8. Example x-ray images taken with a 2 scanning... X-ray imaging tests of Constellation-X SXT mirror segment pairs ... Source: Christian, Eric - Laboratory for High...

435

E-Print Network 3.0 - adc x-ray binary Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

-Planck code and its applications . . . 63 3.6.7 Observation of X-ray binaries with Simbol... for the hard X-ray emission of accreting black holes sources (both in Seyfert...

436

The Hard X-Ray Nanoprobe Beamline at Argonne National Laboratory  

Science Journals Connector (OSTI)

The hard X-ray nanoprobe at the Advanced Photon Source provides characterizing of composition and structure of nanoscale materials and devices with high spatial-resolution using x-ray...

Maser, Jörg; Holt, Martin V; Winarski, Robert P; Rose, Volker; Stephenson, Gregory Brian; Fuesz, Peter

437

E-Print Network 3.0 - angle x-ray studies Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

work as a preionization source... of with and without applying x-ray photons to the HF laser. Since dose rate of the cw x-ray generator is easily Source: Ecole Polytechnique,...

438

E-Print Network 3.0 - accreting x-ray binaries Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Collection: Physics 27 Broad-band spectral properties of accreting X-ray binary pulsars Mauro Orlandini * Summary: Broad-band spectral properties of accreting X-ray binary pulsars...

439

Synchrotron x-ray reflectivity study of oxidation/passivation of copper and silicon.  

SciTech Connect (OSTI)

Synchrotron x-ray-scattering technique studies of copper and silicon electrochemical interfaces are reported. These two examples illustrate the application of synchrotron x-ray techniques for oxidation, passivation, and dissolution of metals and semiconductors.

Chu, Y.; Nagy, Z.; Parkhutik, V.; You, H.

1999-07-21T23:59:59.000Z

440

E-Print Network 3.0 - astronomical hard x-ray Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

search results for: astronomical hard x-ray Page: << < 1 2 3 4 5 > >> 1 Reverse Drift Bursts in the 0.8-4.5 GHz Band and their Relation to X-Rays Summary: and causing radio...

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

E-Print Network 3.0 - attosecond kev x-ray Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

de Montral Collection: Engineering 3 Generation of Attosecond X-ray and gamma-ray via Compton backscattering Summary: Generation of Attosecond X-ray and gamma-ray via...

442

Design and development of a 3D X-ray microscope  

E-Print Network [OSTI]

The rapid development of needle-free injection systems demands better and faster imaging systems, capable of imaging the transient and steady state response of an injection into real tissue. X-ray radiography, x-ray ...

Brayanov, Jordan, 1981-

2006-01-01T23:59:59.000Z

443

High-Frequency X-ray Beam Chopper Based on Diffraction by Surface Acoustic Waves  

Science Journals Connector (OSTI)

The main characteristics of a new type of X-ray beam are presented. Diffraction of X-rays by a pulsed surface acoustic wave is used to perform a flexible high-frequency selection of synchrotron radiation pulses.

Tucoulou, R.

1998-11-01T23:59:59.000Z

444

E-Print Network 3.0 - advanced x-ray techniques Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Astronomy, X-ray Optics and mMcroscopy Grouip Collection: Physics 50 Co-location of lightning leader x-ray and electric field change sources J. Howard,1 Summary: TOA...

445

Soft X-Ray Spectroscopic Study of Dense Strontium-Doped Lanthanum...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Soft X-Ray Spectroscopic Study of Dense Strontium-Doped Lanthanum Manganite Cathodes for Solid Oxide Fuel Cell Applications. Soft X-Ray Spectroscopic Study of Dense Strontium-Doped...

446

X-rays only when you want them: Report on Pseudo-single-bunch...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Room 108A Speaker: David Robin, Lawrence Berkeley National Laboratory Program Description Laser pump - x-ray probe experiments require control over the x-ray pulse pattern and...

447

Triple-Energy X-Ray Absorptiometry for Determination of the Bone Mineral Content in Vivo  

Science Journals Connector (OSTI)

Dual-energy X-ray absorptiometry (DXA) is a ... method for the determination of the bone mineral content in vivo. It has a high precision ... bone. The present work describes a triple-energy X-ray absorptiometry ...

Janos Szücs; Ragnar Jonson; Tommy Hansson

1993-01-01T23:59:59.000Z

448

E-Print Network 3.0 - anomalous x-ray diffraction Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

National Laboratory Superconducting wiggler 7. Low-energy Anomalous X-ray... 1. High-energy x-ray micro-mapping of materials for advanced energy and structural engineering......

449

X-ray absorption study of the electronic structure of Mn-doped amorphous Si  

E-Print Network [OSTI]

X-ray absorption study of the electronic structure of Mn-?x ) is studied by X-ray absorption spectroscopy at the Mn Land featureless L 3,2 absorption peaks, corresponding to an

Zeng, Li

2008-01-01T23:59:59.000Z

450

An in-situ cell for characterization of solids by soft X-ray absorption  

E-Print Network [OSTI]

Scientific Instruments a Absorption (a.u. ) b d 0.01 abs cJ. Lynch, in X-ray Absorption Fine Structure for Catalysts18, pp. 431-512. X-ray Absorption: Principles, Applications,

2007-01-01T23:59:59.000Z

451

E-Print Network 3.0 - alpha tagged x-ray Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

-X-ray pinhole camera -Fast electron beam spatial distribution 5m... ? Fusion Energy Fast Ignition Optimisation high power laser-driven ion -Cu K-alpha imaging system -X-ray... and...

452

E-Print Network 3.0 - anomalous x-ray fluorescence Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in the emission of a fluorescent X-ray. As a rule of thumb 15... Optimization of X-ray energy resolution from a horizontally focused ... Source: Hendrickson, Wayne A. -...

453

X-ray and neutron scattering from nano-mgantic clusters | The...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-ray and neutron scattering from nano-mgantic clusters The student will participate in hands on X-ray scattering experiments on bio-inspired inorganic materials (i.e., magnetic...

454

An X-ray and neutron reflectometry study of ‘PEG-like’ plasma polymer films  

Science Journals Connector (OSTI)

...23 39 131 An X-ray and neutron reflectometry study of plasma polymer films...QCM-D), X-ray and neutron reflectometry (NR). The combination...material properties. The use of neutron reflectometry (NR) in combination with...

2012-01-01T23:59:59.000Z

455

X-Ray Imaging of the Dynamic Magnetic Vortex Core Deformation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-Ray Imaging of the Dynamic Magnetic Vortex Core Deformation X-Ray Imaging of the Dynamic Magnetic Vortex Core Deformation Print Wednesday, 25 November 2009 00:00 Magnetic...

456

New Zone Plate for Soft X-Ray Microscopy at 15-nm Spatial Resolution  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

New Zone Plate for Soft X-Ray Microscopy at 15-nm Spatial Resolution New Zone Plate for Soft X-Ray Microscopy at 15-nm Spatial Resolution Print Wednesday, 31 August 2005 00:00...

457

High Resolution X-Ray Scattering at Sector 3, Advanced Photon...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sector 3 Beamlines Staff Publications Conferences IXN group Sector 3 : High Resolution X-ray Scattering Sector 3 is operated by the Inelastic X-ray Nuclear Resonant Scattering...

458

X-ray Image Bank Open for Business - NERSC Center News, Feb 22...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

X-ray Image Bank Open for Business X-ray Image Bank Open for Business February 22, 2011 Filipe Maia is building a data bank where scientists from around the world can deposit and...

459

Resonant Soft X-Ray Scattering of Tri-Block Copolymers  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Resonant Soft X-Ray Scattering of Tri-Block Copolymers Resonant Soft X-Ray Scattering of Tri-Block Copolymers Print Wednesday, 30 May 2012 00:00 In principle, tri-block copolymers...

460

Fuel Injection and Spray Research Using X-Ray Diagnostics | Department...  

Broader source: Energy.gov (indexed) [DOE]

Injection and Spray Research Using X-Ray Diagnostics Fuel Injection and Spray Research Using X-Ray Diagnostics 2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies...

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Soft X-ray Pulsations in Solar Flares  

E-Print Network [OSTI]

The soft X-ray emissions of solar flares come mainly from the bright coronal loops at the highest temperatures normally achieved in the flare process. Their ubiquity has led to their use as a standard measure of flare occurrence and energy, although the bulk of the total flare energy goes elsewhere. Recently Dolla et al. (2012) noted quasi-periodic pulsations (QPP) in the soft X-ray signature of the X-class flare SOL2011-02-15, as observed by the standard photometric data from the GOES (Geostationary Operational Environmental Satellite) spacecraft. We analyze the suitability of the GOES data for this kind of analysis and find them to be generally valuable after Sept. 2010 (GOES-15). We then extend Dolla et al. results to a list of X-class flares from Cycle 24, and show that most of them display QPP in the impulsive phase. During the impulsive phase the footpoints of the newly-forming flare loops may also contribute to the observed soft X-ray variations. The QPP show up cleanly in both channels of the GOES dat...

Simões, Paulo J A; Fletcher, Lyndsay

2014-01-01T23:59:59.000Z

462

X-ray photon correlation spectroscopy under flow  

E-Print Network [OSTI]

X-ray photon correlation spectroscopy was used to probe the diffusive dynamics of colloidal particles in a shear flow. Combining X-ray techniques with microfluidics is an experimental strategy that reduces the risk of x-ray induced beam damage and also allows time-resolved studies of processes taking place in flowcells. The experimental results and theoretical predictions presented here, show that in the low shear limit, for a ``transverse flow'' scattering geometry (scattering wave vector q perpendicular to the direction of flow) the measured relaxation times are independent of the flow rate and determined only by the diffusive motion of the particles. This is not generally valid and in particular, for a ``longitudinal flow'' (q || flow) scattering geometry, the relaxation times are strongly affected by the flow-induced motion of the particles. Our results show that the Brownian diffusion of colloidal particles can be measured in a flowing sample and that, up to flux limitations, the experimental conditions under which this is possible are easier to achieve at higher values of q.

Andrei Fluerasu; Abdellatif Moussaid; Henri Gleyzolle; Peter Falus; Anders Madsen

2008-03-10T23:59:59.000Z

463

The X-ray eclipse geometry of CAL 87  

E-Print Network [OSTI]

We explore XMM-{\\it Newton} observations of the eclipsing super-soft X-ray source CAL~87 in order to map the accretion structures of the system. { Indirect imaging techniques were applied in X-ray light curves to provide eclipse maps}. The surface brightness distribution exhibits an extended and symmetric emission, { and from the hardest X-rays is revealed a feature that is likely due to a bright spot}. A rate of $\\dot{P} = (+6\\pm2) \\times 10^{-10}$ for changes in the orbital period of the system was derived from the eclipses. There is no significant variation of the emission lines even during eclipses, arguing that the lines are formed in an extended region. The continuum emission dominates the decrease in flux which is observed during eclipses. The O\\,{\\small VIII} Ly$\\alpha$ line reveals a broadening velocity { which is} estimated in 365$^{+65}_{-69}$ km\\,s$^{-1}$ (at 1$\\sigma$) and marginal evidence for asymmetry in its profile, and sometimes shows evidence of double-peaked emission. Together, the results...

Ribeiro, T; Borges,; W, B

2014-01-01T23:59:59.000Z

464

Diffuse X-rays from the Arches and Quintuplet clusters  

E-Print Network [OSTI]

The origin and initial mass function of young stellar clusters near the Galactic center are still poorly understood. Two of the more prominent ones, the Arches and Quintuplet clusters, may have formed from a shock-induced burst of star formation, given their similar age and proximity to each other. Their unusual mass distribution, however, may be evidence of a contributing role played by other factors, such as stellar capture from regions outside the clusters themselves. Diffuse X-ray emission from these sources provides us with a valuable, albeit indirect, measure of the stellar mass-loss rate from their constituents. Using recent data acquired with Chandra, we can study the nature and properties of the outflow to not only probe the pertinent physical conditions, such as high metallicity, the magnetic field, and so forth, but also to better constrain the stellar distribution within the clusters, in order to identify their formative history. In this paper, we present a set of three-dimensional smoothed particle hydrodynamics simulations of the wind-wind interactions in both the Arches and Quintuplet clusters. We are guided primarily by the currently known properties of the constituent stars, though we vary the mass-loss rates in order to ascertain the dependence of the measured X-ray flux on the assumed stellar characteristics. Our results are compared with the latest observations of the Arches cluster. Our analysis of the Quintuplet cluster may be used as a basis for comparison with future X-ray observations of this source.

Gabriel Rockefeller; Chris L. Fryer; Fulvio Melia; Q. Daniel Wang

2005-01-25T23:59:59.000Z

465

X-ray Dip Monitoring of XB 1916-053  

E-Print Network [OSTI]

We report on the long term monitoring of X-ray dips from the ultracompact low-mass X-ray binary (LMXB) XB 1916-053. Roughly one-month interval observations were carried out with the Rossi X-ray Timing Explorer (RXTE) during 1996, during which the source varied between dim, hard states and more luminous, soft states. The dip spectra and dip lightcurves were compared against both the broadband luminosity and the derived mass accretion rate Mdot. The dips spectra could be fitted by an absorbed blackbody plus cut-off power law non-dip spectral model, with additional absorption ranging from 0 to >100 x 10^22 cm^-2. The amount of additional blackbody absorption was found to vary with the source luminosity. Our results are consistent with an obscuration of the inner disk region by a partially ionized outer disk. The size of the corona, derived from the dip ingress times, was found to be ~10^9 cm. The corona size did not correlate with the coronal temperature, but seemed to increase when \\Mdot also increased. We discuss our findings in the context of an evaporated accretion disk corona model and an ADAF-type model.

T. Narita; J. E. Grindlay; P. F. Bloser; Y. Chou

2003-05-06T23:59:59.000Z

466

X-ray Emission Processes in Radio Jets  

E-Print Network [OSTI]

The emission processes responsible for the observed X-rays from radio jets are commonly believed to be non-thermal, but in any particular case, it is unclear if synchrotron emission or one or more varieties of inverse Compton emission predominates. We present a formulation of inverse Compton emission from a relativistically moving jet (``IC/beaming'') which relies on radio emitting synchrotron sources for which the energy densities in particles and fields are comparable. We include the non-isotropic nature of inverse Compton scattering of the relativistic electrons on photons of the cosmic microwave background (CMB) and provide beaming parameters for a number of jets. A list of X-ray emitting jets is given and the jets are classified on the basis of their morphology and spectral energy distribution to determine their likely emission process. We conclude that these jets have significant bulk relativistic velocities on kpc scales; that higher redshift sources require less beaming because the energy density of the CMB is significantly greater than locally; and that for some nearby sources, synchrotron X-ray emission predominates because the jet makes a large angle to the line of sight.

D. E. Harris; H. Krawczynski

2001-09-27T23:59:59.000Z

467

Size dependence of solar X-ray flare properties  

E-Print Network [OSTI]

Non-thermal and thermal parameters of 85 solar flares of GOES class B1 to M6 (background subtracted classes A1 to M6) have been compared to each other. The hard X-ray flux has been measured by RHESSI and a spectral fitting provided flux and spectral index of the non-thermal emission, as well as temperature and emission measure of the thermal emission. The soft X-ray flux was taken from GOES measurements. We find a linear correlation in a double logarithmic plot between the non-thermal flux and the spectral index. The higher the acceleration rate of a flare, the harder the non-thermal electron distribution. The relation is similar to the one found by a comparison of the same parameters from several sub-peaks of a single flare. Thus small flares behave like small subpeaks of large flares. Thermal flare properties such as temperature, emission measure and the soft X-ray flux also correlate with peak non-thermal flux. A large non-thermal peak flux entails an enhancement in both thermal parameters. The relation between spectral index and the non-thermal flux is an intrinsic feature of the particle acceleration process, depending on flare size. This property affects the reported frequency distribution of flare energies.

Marina Battaglia; Paolo C. Grigis; Arnold O. Benz

2005-05-09T23:59:59.000Z

468

A Compact Pressure-Insulated Electrostatic X-Ray Generator  

Science Journals Connector (OSTI)

A compact, pressure-insulated, electrostatic x-ray generator has been developed for scientific and medical purposes. A major object of the work was the investigation, with a small and thus flexible machine, of the principles and design factors involved in pressure-insulated electrostatic generators with a view to the subsequent development of higher voltages in compact apparatus. The generator is housed in a steel tank 34 in. in diameter and 100 in. high. At air pressures of 11 atmospheres absolute, 1250-kv x-rays are obtained with target currents of over one milliampere supplied by the single 14-in. belt. With Freon gas the same voltages and currents can be obtained at one-third the pressure required with air. The problem of belt charge is analyzed and a method is described for controlling the electrostatic fields within the column in order to realize the high charge densities possible at high pressure. The construction of a supporting column of high breakdown strength, and other features of the design are described. At 1250 kv the x-ray intensity per milliampere of target current is about 340 roentgens per minute at 50 cm from the target in the direction of the electron beam with five mm of lead equivalent filtration.

John G. Trump and R. J. van de Graaff

1939-06-15T23:59:59.000Z

469

Tomographic X-ray data of a walnut  

E-Print Network [OSTI]

This is the documentation of the tomographic X-ray data of a walnut made available at http://www.fips.fi/dataset.php . The data can be freely used for scientific purposes with appropriate references to the data and to this document in arXiv. The data set consists of (1) the X-ray sinogram of a single 2D slice of the walnut with three different resolutions and (2) the corresponding measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 120-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution. In addition, a larger set of 1200 projections of the same walnut was measured and a high-resolution filtered back-projection reconstruction was computed from this data; both the sinogram and the FBP reconstruction are included in the data set, the latter serving as a ground truth reconstruction.

Hämäläinen, Keijo; Kallonen, Aki; Kujanpää, Antti; Niemi, Esa; Siltanen, Samuli

2015-01-01T23:59:59.000Z

470

Non-Destructive X-ray Measurement of Soot, Ash, Washcoat and Regeneration Damage for DPFs  

Broader source: Energy.gov [DOE]

New commercially avaliable non-destructive x-ray techniques are used to make measurements on diesel particulate filters.

471

Femtosecond X-ray diffraction from two-dimensional protein crystals  

Science Journals Connector (OSTI)

Bragg diffraction achieved from two-dimensional protein crystals using femtosecond X-ray laser snapshots is presented.

Frank, M.

2014-02-28T23:59:59.000Z

472

X-ray reflectivity measurements of liquid/solid interfaces under high hydrostatic pressure conditions  

Science Journals Connector (OSTI)

A high hydrostatic pressure cell for X-ray reflectivity measurements at the solid/liquid interface is presented.

Wirkert, F.J.

2013-11-02T23:59:59.000Z

473

Final report: high resolution lensless 3D imaging of nanostructures with coherent x-rays  

SciTech Connect (OSTI)

Final report on the project "High resolution lensless 3D imaging of nanostructures with coherent x-rays"

Jacobsen, Chris

2014-12-07T23:59:59.000Z

474

Crystallization and preliminary X-ray analysis of a hydantoinase from Artrobacter aurescens DSM 3745  

Science Journals Connector (OSTI)

A hydantoinase from Artrobacter aurescens DSM 3745 has been crystallized and preliminary X-ray analysis has been performed.

May, O.

1996-11-01T23:59:59.000Z

475

Supplemental information I. OPTICAL-LASER AND X-RAY CONFIGURATION  

E-Print Network [OSTI]

Supplemental information I. OPTICAL-LASER AND X-RAY CONFIGURATION The experiment used 70 fs x-ray and x-ray pulses was established by the initial decrease in the 111 diffraction peak in a laser pulses at 10 keV from the LCLS in the high-charge (250 pC) mode at 120 Hz. The x-ray beam was focused

Loss, Daniel

476

Double-Layer Silicon PIN Photodiode X-Ray Detector for a Future X-ray Timing Mission  

E-Print Network [OSTI]

A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective area of 6 mm^2. The detector performs best at -35 C with an energy resolution of 220 eV (FWHM, full width at half maximum) at 5.9 keV, and is able to operate at room temperature, +25 C, with moderate resolution around 760 eV (FWHM). The response of the top layer sensor is highly uniform across the sensitive area. This large-format silicon detector is appropriate for future X-ray timing missions.

Hua Feng; Philip Kaaret; Hans Andersson

2006-06-01T23:59:59.000Z

477

Feasibility considerations of a soft-x-ray distributed feedback laser pumped by an x-ray free electron laser  

E-Print Network [OSTI]

We discuss the feasibility of a soft-x-ray distributed feedback laser (DFL) pumped by an x-ray free electron laser (X-FEL). The DFL under consideration is a Mg/SiC bi-layered Bragg reflector pumped by a single X-FEL bunch at 57.4 eV, stimulating the Mg L2,3 emission at 49 eV corresponding to the 3s-3d â??2p1/2,3/2 transition. Based on a model developed by Yariv and Yeh and an extended coupled-wave theory, we show that it would be possible to obtain a threshold gain compatible with the pumping provided by available X-FEL facilities.

André, Jean-Michel; Jonnard, Philippe

2014-01-01T23:59:59.000Z

478

A volume-limited sample of X-ray galaxy groups and clusters - II. X-ray cavity dynamics  

E-Print Network [OSTI]

We present the results of our study of a volume-limited sample (z cooling time of less than3 Gyr. New X-ray cavities are detected in three sources. We focus on the subset of sources that have a central cooling time of less than 3 Gyr, whose active galactic nucleus (AGN) duty cycle is approximately 61 percent (30/49). This rises to over 80 percent for a central cooling time of less than 0.5 Gyr. When projection effects and central radio source detection rates are considered, the actual duty cycle is probably much higher. In addition, we show that data quality strongly affects the detection rates of X-ray cavities. After calculating the cooling luminosity and cavity powers of each source with cavities, it is evident that the bubbling process induced by the central AGN has to be, on average, continuo...

Panagoulia, E K; Sanders, J S; Hlavacek-Larrondo, J

2014-01-01T23:59:59.000Z

479

Plasma X-ray Spectra Analysis Using Genetic Algorithms Igor E. Golovkin  

E-Print Network [OSTI]

Plasma X-ray Spectra Analysis Using Genetic Algorithms Igor E. Golovkin Department of Physics for plasma diagnostics. We use genetic algorithms to automatically analyze experi- mental X-ray line spectra-ray line spectra. 1 INTRODUCTION X-ray spectroscopic analysis is a widely used method for hot dense plasma

Louis, Sushil J.

480

X-ray timing of the accreting millisecond pulsar SAX J1808.4-3658  

E-Print Network [OSTI]

We present a 7 yr timing study of the 2.5 ms X-ray pulsar SAX J1808.4-3658, an X-ray transient with a recurrence time of =2 yr, using data from the Rossi X-ray Timing Explorer covering 4 transient outbursts (1998-2005). ...

Hartman, Jacob M., Ph. D. Massachusetts Institute of Technology

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "x-rays volker urban" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Accepted Manuscript Laboratory-based recording of holographic fine structure in x-ray absorption  

E-Print Network [OSTI]

be only performed using synchrotron radiation. Keywords: x-ray absorption, atomic structure, xAccepted Manuscript Laboratory-based recording of holographic fine structure in x-ray absorption structure in x-ray absorption anisotropy using polycapillary optics, Nucl. Instr. and Meth. in Phys. Res. B

Korecki, Pawe³

482

Directional fine structure in absorption of white x rays: A tomographic interpretation P. Korecki,1,  

E-Print Network [OSTI]

structure in absorption of white x rays can be interpreted as real-space projections of atomic structure from neigh- boring atoms.1 A straightforward analysis of the extended x-ray absorption fine structure of the absorbing atoms. Thus, the absorption cross section is effectively modulated by the x-ray scattering

Korecki, Pawe³

483

Soft X-Ray and Vacuum Ultraviolet Based Spectroscopy of the Actinides  

SciTech Connect (OSTI)

The subjects of discussion included: VUV photoelectron spectroscopy, X-ray photoelectron spectroscopy, Synchrotron-radiation-based photoelectron spectroscopy, Soft x-ray absorption spectroscopy, Soft x-ray emission spectroscopy, Inverse photoelectron spectroscopy, Bremstrahlung Isochromat Spectroscopy, Low energy IPES, Resonant inverse photoelectron spectroscopy.

Tobin, J G

2011-03-17T23:59:59.000Z

484

Measuring the power spectrum of density fluctuations at intermediate redshift with X-ray background observations  

Science Journals Connector (OSTI)

......arguments at soft X-ray energies (see, e.g., Car- rera, Fabian...telescopes working up to energies #10 keV. This is...flux downwards. An alternative way of using an X-ray...ROSAT at soft X-ray energies (Voges 1993) and......

X. Barcons; A. C. Fabian; F. J. Carrera

1998-01-01T23:59:59.000Z

485

Femtosecond diffractive imaging with a soft-X-ray free-electron laser  

E-Print Network [OSTI]

LETTERS Femtosecond diffractive imaging with a soft-X-ray free-electron laser HENRY N. CHAPMAN1 of this principle using the FLASH soft-X-ray free-electron laser. An intense 25 fs, 4 Ã? 1013 W cm-2 pulse by one10 . X-ray free-electron lasers (FELs) are expected to permit diffractive imaging at high

Loss, Daniel

486

HARMONIC CASCADE FEL DESIGNS FOR LUX, A FACILTY FOR ULTRAFAST X-RAY SCIENCE  

E-Print Network [OSTI]

-electron laser (FEL) beamlines which use the har- monic cascade approach to produce coherent XUV & soft X-ray for an integrated system of ultrafast x-ray techniques and lasers, using laser-seeded harmonic cascade FEL's, rfHARMONIC CASCADE FEL DESIGNS FOR LUX, A FACILTY FOR ULTRAFAST X-RAY SCIENCE J. Corlett, W. Fawley

Wurtele, Jonathan

487

Massively parallel X-ray holography STEFANO MARCHESINI1,2  

E-Print Network [OSTI]

, and a bacterial cell with a soft-X-ray free-electron laser, where illumination by a single 15-fs pulse was successfully used in producing the holographic image. As X-ray lasers move to shorter wavelengths we expectMassively parallel X-ray holography STEFANO MARCHESINI1,2 *, SE´BASTIEN BOUTET3,4 , ANNE E

Petta, Jason

488

Compression of powerful x-ray pulses to attosecond durations by stimulated Raman backscattering in plasmas  

E-Print Network [OSTI]

the possibility of using powerful x-ray sources for producing ultrahigh laser intensities. It might clarify how much the emerging mJ x-ray laser technologies 1 could compete with the emerging MJ optical laser the biggest of currently built lasers: Linac Coherent Light Source LCLS 1 in x-ray range and megajoule laser

489

An Exact Modeling of Signal Statistics in Energy-integrating X-ray Computed Tomography  

E-Print Network [OSTI]

assumption was made that the number of x-ray quanta within an energy interval in the spectrum followsAn Exact Modeling of Signal Statistics in Energy-integrating X-ray Computed Tomography Yi Fan1 School of Medicine, Atlanta, GA 30322 ABSTRACT Energy-integrating detection of x-ray sources is widely

490

National School on Neutron and X-ray Scattering June 14-28, 2014  

E-Print Network [OSTI]

National School on Neutron and X-ray Scattering June 14-28, 2014 Argonne National Laboratory:00 Dinner Dinner Dinner Dinner Week 1 wrap-up Picnic #12;National School on Neutron and X-ray Scattering Restaurant 9:45 - 10:45 Lecture Interaction of X-rays and Neutrons with Matter Roger Pynn University

Kemner, Ken

491

National School on Neutron and X-ray Scattering August 10-24, 2013  

E-Print Network [OSTI]

National School on Neutron and X-ray Scattering August 10-24, 2013 Argonne National Laboratory National Laboratory 3:15 ­ 3:30 Break #12;National School on Neutron and X-ray Scattering August 10 Dinner Week 1 wrap-up Picnic #12;National School on Neutron and X-ray Scattering August 10-24, 2012 Oak

Kemner, Ken

492

A Novel High-Resolution Alignment Technique for XFEL Using Undulator X-ray Beams  

E-Print Network [OSTI]

1 A Novel High-Resolution Alignment Technique for XFEL Using Undulator X-ray Beams Bingxin Yang Abstract We propose a novel alignment technique utilizing the x-ray beam of an undulator in conjunction a stable and reproducible x-ray beam axis (XBA). Targets are precisely positioned on the XBA using

Kemner, Ken

493

High Redshift X-Ray Selected Quasars: CXOCY J125304.0-090737 joins the club  

E-Print Network [OSTI]

We present a new X-ray selected high redshift quasar CXOCY J125304.0-090737 at z=4.179, discovered by the Calan-Yale Deep Extragalactic Research (CYDER) Survey. This quasar is the fifth X-ray selected high redshift radio quiet quasar ($z>4$) found so far. Here, we present its observed properties which are characterized by its relative optical and X-ray faintness, its X-ray hardness and its X-ray strength compared to optically selected quasars at high redshift. We also compare the X-ray selected high redshift radio quiet quasars to their optically selected counterparts. We find that the optical to X-ray spectral slope, $\\alpha_{ox}$, is statistically harder (more X-ray luminous) for the X-ray selected radio quiet quasars than for the optically selected ones. This result, given the different range of rest frame ultraviolet luminosities studied and the selection of the samples, is consistent with the previously found correlation between X-ray and rest frame ultraviolet luminosities and would extend that result to a much wider luminosity range at high redshift. Finally, we discuss the prospects of unveiling the quasar luminosity function at high redshifts using X-ray surveys. The discovery of a high redshift object in the first field of our survey program provides suggestive evidence that X-ray selected surveys may identify more such objects than would be expected from an extrapolation of the optical luminosity function.

F. J. Castander; E. Treister; T. J. Maccarone; P. S. Coppi; J. Maza; S. E. Zepf; R. Guzman

2003-01-29T23:59:59.000Z

494

High-resolution X-ray diffraction analyses of protein crystals  

Science Journals Connector (OSTI)

...illustration of the X-ray optical system used in the current study...illustrates the X-ray optical system that was used for this study...in a novel X-ray optical system (Matyi et al. 1999), produced...well as a two-dimensional collimation of the incident beam. Both...

1999-01-01T23:59:59.000Z

495

Integral and temporal characteristics of soft X-rays of the PF-4 plasma focus setup  

Science Journals Connector (OSTI)

Soft X-rays of a setup with a power from 1.5 to 5 kJ, operating with argon, were measured using X-ray pinhole cameras and SPPD 11-04 detectors. Integral measurements of X-rays in energy ranges above 1.2, 1.5, ...

S. P. Eliseev; V. Ya. Nikulin; P. V. Silin

2009-01-01T23:59:59.000Z

496

X-ray radiation effects in multilayer epitaxial graphene Jeremy Hicks1  

E-Print Network [OSTI]

1 X-ray radiation effects in multilayer epitaxial graphene Jeremy Hicks1 , Rajan Arora2 , Eleazar and after exposure to a total ionizing dose (TID) of 12 Mrad(SiO2) using a 10 keV X-ray source. While we are mostly unaffected by radiation exposure. Combined with X-ray photoelectron spectroscopy (XPS) data

497

X-ray Diffraction Laboratory: Department of Chemistry Texas A & M University  

E-Print Network [OSTI]

X-ray Diffraction Laboratory: Department of Chemistry Texas A & M University Doc. No: SOPALIGNA Standard Operating Procedure Title: X-ray Instrument Alignment ­ APEXII Rev No: Issue date: 1.001 6 the alignment of the APEXII single crystal X-ray diffractometer. POLICY: The instrument must be aligned

Meagher, Mary

498

X-ray microtomography characterization of porosity, permeability and reactive surface changes during dissolution  

E-Print Network [OSTI]

X-ray microtomography characterization of porosity, permeability and reactive surface changes from X-ray microtomography data obtained before and after a set of dissolution experiments of pure.V. All rights reserved. Keywords: Reactive transport Carbon storage Permeability X-ray microtomography 1

Luquot, Linda

499

X-Ray Conformational Study of the DNA Duplex in Solution  

E-Print Network [OSTI]

X-Ray Conformational Study of the DNA Duplex in Solution V. GRASSIAN* and G. W. BRADY,f Rensselaer Earlier x-ray studies on dissolved linear DNA molecules were interpreted on the assumption engaged in x-ray diffraction studies of circular su- perhelical DNA. Some of our preliminary results have

Benham, Craig J.

500

X-ray dark-field imaging modeling * F. Pfeiffer,2  

E-Print Network [OSTI]

X-ray dark-field imaging modeling W. Cong,1, * F. Pfeiffer,2 M. Bech,2 and G. Wang1 1 Biomedical-field images are formed from x-ray small-angle scattering signals. The small-angle scattering signals to describe the relationship between x-ray small-angle scattering coefficients of an object and dark

Wang, Ge