Sample records for x-ray tomography print

  1. Using X-Ray Computed Tomography in Pore Structure Characterization...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Using X-Ray Computed Tomography in Pore Structure Characterization for a Berea Sandstone: Resolution Effect. Using X-Ray Computed Tomography in Pore Structure Characterization for...

  2. Regularized Equally Sloped Tomography Algorithm for Low Dose X-Ray Computed Tomography

    E-Print Network [OSTI]

    Zhao, Yunzhe

    2012-01-01T23:59:59.000Z

    based imaging computed tomography extraction algorithms and10 2.2. Computed Tomography reconstruction theory andcontrast X-ray computed tomography for observing biological

  3. Regularized Equally Sloped Tomography Algorithm for Low Dose X-Ray Computed Tomography

    E-Print Network [OSTI]

    Zhao, Yunzhe

    2012-01-01T23:59:59.000Z

    based imaging computed tomography extraction algorithms andcontrast X-ray computed tomography for observing biological10 2.2. Computed Tomography reconstruction theory and

  4. Modeling pure methane hydrate dissociation using a numerical simulator from a novel combination of X-ray computed tomography and macroscopic data

    E-Print Network [OSTI]

    Gupta, A.

    2010-01-01T23:59:59.000Z

    Combination of X-ray Computed Tomography and Macroscopicdissociation data. X-ray computed tomography (CT) was usedobtained from x-ray computed tomography analysis combined

  5. X-ray Computed Tomography of the Root System of a Live Potted...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-ray Computed Tomography of the Root System of a Live Potted Plant X-ray Computed Tomography of the Root System of a Live Potted Plant Being able to see the root structure of a...

  6. Using X-ray computed tomography in pore structure characterization for a Berea sandstone: Resolution effect

    E-Print Network [OSTI]

    Hu, Qinhong "Max"

    Using X-ray computed tomography in pore structure characterization for a Berea sandstone Keywords: XCT Pore structure characterization Resolution effect MIP s u m m a r y X-ray computed tomography electron microscopy (Ioannidis et al., 1996), X-ray computed tomography (XCT) with either conventional

  7. Data fusion in neutron and X-ray computed tomography

    SciTech Connect (OSTI)

    Schrapp, Michael J. [Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81739 Munich (Germany); Physik Department E21, Technische Universität München, James-Franck-Strasse 1, 85747 Garching (Germany); Goldammer, Matthias [Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81739 Munich (Germany); Schulz, Michael [Physik Department E21, Technische Universität München, James-Franck-Strasse 1, 85747 Garching (Germany); Heinz Maier-Leibnitz Zentrum (MLZ), Technische Universität München, Lichtenbergstrasse 1, 85747 Garching (Germany); Issani, Siraj; Bhamidipati, Suryanarayana [Siemens AG, Corporate Technology, Bangalore (India); Böni, Peter [Physik Department E21, Technische Universität München, James-Franck-Strasse 1, 85747 Garching (Germany)

    2014-10-28T23:59:59.000Z

    We present a fusion methodology between neutron and X-ray computed tomography (CT). On the one hand, the inspection by X-ray CT of a wide class of multimaterials in non-destructive testing applications suffers from limited information of object features. On the other hand, neutron imaging can provide complementary data in such a way that the combination of both data sets fully characterizes the object. In this contribution, a novel data fusion procedure, called Fusion Regularized Simultaneous Algebraic Reconstruction Technique, is developed where the X-ray reconstruction is modified to fulfill the available data from the imaging with neutrons. The experiments, which were obtained from an aluminum profile containing a steel screw, and attached carbon fiber plates demonstrate that the image quality in CT can be significantly improved when the proposed fusion method is used.

  8. In Situ X-Ray Scattering Helps Optimize Printed Solar Cells

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    In Situ X-Ray Scattering Helps Optimize Printed Solar Cells In Situ X-Ray Scattering Helps Optimize Printed Solar Cells Print Wednesday, 25 February 2015 00:00 Plastic solar cells...

  9. X-ray tomography system to investigate granular materials during mechanical loading

    E-Print Network [OSTI]

    Athanassiadis, Athanasios G; Sidky, Emil; Pelizzari, Charles; Pan, Xiaochuan; Jaeger, Heinrich M

    2014-01-01T23:59:59.000Z

    We integrate a small and portable medical x-ray device with mechanical testing equipment to enable in-situ, non-invasive measurements of a granular material's response to mechanical loading. We employ an orthopedic C-arm as the x-ray source and detector to image samples mounted in the materials tester. We discuss the design of a custom rotation stage, which allows for sample rotation and tomographic reconstruction under applied compressive stress. We then discuss the calibration of the system for 3d computed tomography, as well as the subsequent image reconstruction process. Using this system to reconstruct packings of 3d-printed particles, we resolve packing features with 0.52 mm resolution in a (60 mm)$^3$ field of view. By analyzing the performance bounds of the system, we demonstrate that the reconstructions exhibit only moderate noise.

  10. X-ray tomography system to investigate granular materials during mechanical loading

    E-Print Network [OSTI]

    Athanasios G Athanassiadis; Patrick J. La Rivičre; Emil Sidky; Charles Pelizzari; Xiaochuan Pan; Heinrich M. Jaeger

    2014-07-28T23:59:59.000Z

    We integrate a small and portable medical x-ray device with mechanical testing equipment to enable in-situ, non-invasive measurements of a granular material's response to mechanical loading. We employ an orthopedic C-arm as the x-ray source and detector to image samples mounted in the materials tester. We discuss the design of a custom rotation stage, which allows for sample rotation and tomographic reconstruction under applied compressive stress. We then discuss the calibration of the system for 3d computed tomography, as well as the subsequent image reconstruction process. Using this system to reconstruct packings of 3d-printed particles, we resolve packing features with 0.52 mm resolution in a (60 mm)$^3$ field of view. By analyzing the performance bounds of the system, we demonstrate that the reconstructions exhibit only moderate noise.

  11. X-ray tomography system to investigate granular materials during mechanical loading

    SciTech Connect (OSTI)

    Athanassiadis, Athanasios G. [James Franck Institute and Department of Physics, The University of Chicago, Chicago, Illinois 60637 (United States); Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); La Rivičre, Patrick J.; Sidky, Emil; Pan, Xiaochuan [Department of Radiology, The University of Chicago, Chicago, Illinois 60637 (United States); Pelizzari, Charles [Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637 (United States); Jaeger, Heinrich M., E-mail: h-jaeger@uchicago.edu [James Franck Institute and Department of Physics, The University of Chicago, Chicago, Illinois 60637 (United States)

    2014-08-15T23:59:59.000Z

    We integrate a small and portable medical x-ray device with mechanical testing equipment to enable in situ, non-invasive measurements of a granular material's response to mechanical loading. We employ an orthopedic C-arm as the x-ray source and detector to image samples mounted in the materials tester. We discuss the design of a custom rotation stage, which allows for sample rotation and tomographic reconstruction under applied compressive stress. We then discuss the calibration of the system for 3D computed tomography, as well as the subsequent image reconstruction process. Using this system to reconstruct packings of 3D-printed particles, we resolve packing features with 0.52?mm resolution in a (60 mm){sup 3} field of view. By analyzing the performance bounds of the system, we demonstrate that the reconstructions exhibit only moderate noise.

  12. An Exact Modeling of Signal Statistics in Energy-integrating X-ray Computed Tomography

    E-Print Network [OSTI]

    An Exact Modeling of Signal Statistics in Energy-integrating X-ray Computed Tomography Yi Fan1 used by modern computed tomography (CT) scanners and has been an interesting research topic 1. INTRODUCTION In x-ray computed tomography (CT), Poisson noise model has been widely used in noise

  13. The color of X-rays Spectral X-ray computed tomography using energy sensitive pixel detectors

    E-Print Network [OSTI]

    Schioppa, Enrico Junior

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray fluorescence. The charge transport properties of the sensor are characterized using a high energy beam of charged particles at the Super Proton Synchrotron (SPS) at the European Center for Nuclear Research (CERN). Monochromatic X-rays at the European Synchrotron Radiation Facility (ESRF) are used to determined the energy response function. These data are used to implement a physics-based CT projection operator that accounts for the transmission of the source spectrum through the sample and detector effects. Based on this projection operator, an iterative spectral CT reconstruction algorithm is developed by extending an Ordered Subset Expectation Maximization (OSEM) method. Subsequently, a maximum likelihood based algo...

  14. Penalized Weighted Least-Squares Approach for Low-Dose X-Ray Computed Tomography

    E-Print Network [OSTI]

    Penalized Weighted Least-Squares Approach for Low-Dose X- Ray Computed Tomography Jing Wang*1, noise-resolution tradeoff, ROC curve. 1. INTRODUCTION Low-dose X-ray computed tomography (CT) imaging Military Medical University, Xi'an, Shaanxi 710032, China ABSTRACT The noise of low-dose computed

  15. Using X-ray computed tomography in hydrology: systems, resolutions, and limitations

    E-Print Network [OSTI]

    Wildenschild, Dorthe

    Using X-ray computed tomography in hydrology: systems, resolutions, and limitations D to characterize phase distribution and pore geometry in porous media using non-destructive X-ray computed tomography (CT). We present qualitative and quantitative CT results for partially saturated media, obtained

  16. X-ray Computed Tomography of coal: Final report

    SciTech Connect (OSTI)

    Maylotte, D.H.; Spiro, C.L.; Kosky, P.G.; Lamby, E.J.

    1986-12-01T23:59:59.000Z

    X-ray Computed Tomography (CT) is a method of mapping with x-rays the internal structures of coal. The technique normally produces 2-D images of the internal structures of an object. These images can be recast to create pseudo 3-D representations. CT of coal has been explored for a variety of different applications to coal and coal processing technology. In a comparison of CT data with conventional coal analyses and petrography, CT was found to offer a good indication of the total ash content of the coal. The spatial distribution of the coal mineral matter as seen with CT has been suggested as an indicator of coal washability. Studies of gas flow through coal using xenon gas as a tracer have shown the extremely complicated nature of the modes of penetration of gas through coal, with significant differences in the rates at which the gas can pass along and across the bedding planes of coal. In a special furnace designed to allow CT images to be taken while the coal was being heated, the pyrolysis and gasification of coal have been studied. Gasification rates with steam and CO/sub 2/ for a range of coal ranks have been obtained, and the location of the gasification reactions within the piece of coal can be seen. Coal drying and the progress of the pyrolysis wave into coal have been examined when the coal was subjected to the kind of sudden temperature jump that it might experience in fixed bed gasifier applications. CT has also been used to examine stable flow structures within model fluidized beds and the accessibility of lump coal to microbial desulfurization. 53 refs., 242 figs., 26 tabs.

  17. Introducing Minimum Fisher Regularisation Tomography to Bolometric and Soft X-ray Diagnostic Systems of the COMPASS Tokamak

    E-Print Network [OSTI]

    Introducing Minimum Fisher Regularisation Tomography to Bolometric and Soft X-ray Diagnostic Systems of the COMPASS Tokamak

  18. X-ray micromodulated luminescence tomography in dual-cone ...

    E-Print Network [OSTI]

    2014-07-01T23:59:59.000Z

    Jul 16, 2014 ... ing the intensity of x-ray energy at the vertex point of a double- cone beam. ... such focusing element, but it is of low efficiency and restricted.

  19. Novel Application of X-ray Computed Tomography: Determination of Gas/Liquid Contact Area and Liquid Holdup in Structured Packing

    E-Print Network [OSTI]

    Eldridge, R. Bruce

    Novel Application of X-ray Computed Tomography: Determination of Gas/Liquid Contact Area and Liquid Company, 1 Neumann Way-M/D Q8, Cincinnati, Ohio 45215 X-ray computed tomography (CT) was utilized Principles of X-ray Computed Tomography. X-ray computed tomography (CT) is used to noninvasively

  20. A metallography and x-ray tomography study of spall damage in ultrapure Al

    SciTech Connect (OSTI)

    Qi, M. L. [School of Science, Wuhan University of Technology, Wuhan, Hubei 430070 (China); HPSynC@Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Bie, B. X. [School of Science, Wuhan University of Technology, Wuhan, Hubei 430070 (China); The Peac Institute of Multiscale Sciences and Sichuan University, Chengdu, Sichuan 610207 (China); Zhao, F. P.; Fan, D.; Luo, S. N., E-mail: sluo@pims.ac.cn [The Peac Institute of Multiscale Sciences and Sichuan University, Chengdu, Sichuan 610207 (China); Hu, C. M. [HPSynC@Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); National Key Laboratory of Shock Wave and Detonation Physics, Chinese Academy of Engineering Physics, Mianyang, Sichuan 621900 (China); Ran, X. X. [School of Science, Wuhan University of Technology, Wuhan, Hubei 430070 (China); Xiao, X. H. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Yang, W. G., E-mail: wenge@aps.anl.gov [HPSynC@Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Li, P. [National Key Laboratory of Shock Wave and Detonation Physics, Chinese Academy of Engineering Physics, Mianyang, Sichuan 621900 (China)

    2014-07-15T23:59:59.000Z

    We characterize spall damage in shock-recovered ultrapure Al with metallography and x-ray tomography. The measured damage profiles in ultrapure Al induced by planar impact at different shock strengths, can be described with a Gaussian function, and showed dependence on shock strengths. Optical metallography is reasonably accurate for damage profile measurements, and agrees within 10–25% with x-ray tomography. Full tomography analysis showed that void size distributions followed a power law with an exponent of ? = 1.5 ± 2.0, which is likely due to void nucleation and growth, and the exponent is considerably smaller than the predictions from percolation models.

  1. PERTURBATION-BASED ERROR ANALYSIS OF ITERATIVE IMAGE RECONSTRUCTION ALGORITHM FOR X-RAY COMPUTED TOMOGRAPHY

    E-Print Network [OSTI]

    Fessler, Jeffrey A.

    -ray computed tomography. The effects of the quantization error in forward-projection, back computed tomography (CT) have been proposed to improve image quality and reduce dose [1]. These methodsPERTURBATION-BASED ERROR ANALYSIS OF ITERATIVE IMAGE RECONSTRUCTION ALGORITHM FOR X-RAY COMPUTED

  2. In-line x-ray phase-contrast tomography and diffraction-contrast tomography study of the ferrite-cementite microstructure in steel

    E-Print Network [OSTI]

    van Vliet, Lucas J.

    In-line x-ray phase-contrast tomography and diffraction-contrast tomography study of the ferrite;In-line X-ray phase-contrast tomography and diffraction-contrast tomography study of the ferrite embedded in a ferrite matrix of medium-carbon steel. The measurements were carried out at the material

  3. Three-dimensional morphology of cementite in steel studied by X-ray phase-contrast tomography

    E-Print Network [OSTI]

    Stallinga, Sjoerd

    Three-dimensional morphology of cementite in steel studied by X-ray phase-contrast tomography-destructive, in-line X-ray phase-contrast tomography (PCT) can be used to study the three-dimensional mor- phology- and cold-forming operations of the steel. Studying the evolution of the morphology of cement- ite in 3-D

  4. Degradation of Li/S Battery Electrodes Studied Using X-ray Phase Contrast Tomography

    E-Print Network [OSTI]

    Schmidt, Volker

    in lithium-ion battery systems. This technology is thus drawing attention from academic and industrial researchers intensively studied rechargeable lithium-ion batteries, since the energy demand of electric1 Degradation of Li/S Battery Electrodes Studied Using X-ray Phase Contrast Tomography L. Zielkea

  5. A Hard X-ray KB-FZP Microscope for Tomography with Sub-100-nm Resolution

    E-Print Network [OSTI]

    Braun, Paul

    Bielefeld, Germany, 7 BESSY GmbH, Albert-Einstein-Str.15, 12489 Berlin, Germany 8 Department of Physics. INTRODUCTION Synchrotron-based hard X-ray tomography is nowadays a standard technique for structural analyses sciences, biomedicine, planetary science etc.. The high coherence of third generation synchrotron sources

  6. X-Ray Digital Radiography and Computed Tomography Characterization of Targets

    SciTech Connect (OSTI)

    Sain, J D; Brown, W D; Chinn, D J; Martz Jr., H E; Morales, K E; Schneberk, D J; Updike, E O

    2008-04-16T23:59:59.000Z

    The summary of this report is: (1) The Xradia Micro XCT and LLNL CCAT x-ray systems are used to nondestructively characterize a variety of materials, assemblies, and reference standard components; (2) The digital radiograph (DR) and computed tomography (CT) image data may be used for metrology, quality control, and defect detection; and (3) The ability to detect and characterize imperfections leads to improvements in the manufacturing processes for assemblies.

  7. Cone beam x-ray luminescence computed tomography: A feasibility study

    SciTech Connect (OSTI)

    Chen Dongmei; Zhu Shouping; Yi Huangjian; Zhang Xianghan; Chen Duofang; Liang Jimin [School of Life Sciences and Technology, Xidian University, Xi'an 710071 (China); Tian Jie [School of Life Sciences and Technology, Xidian University, Xi'an 710071 (China); Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, Beijing 100190 (China)

    2013-03-15T23:59:59.000Z

    Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

  8. Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

    SciTech Connect (OSTI)

    Rudati, J.; Tkachuk, A.; Gelb, J.; Hsu, G.; Feng, Y.; Pastrick, R.; Lyon, A.; Trapp, D.; Beetz, T.; Chen, S.; Hornberger, B.; Seshadri, S.; Kamath, S.; Zeng, X.; Feser, M.; Yun, W. [Xradia, Inc., Concord, California (United States); Pianetta, P.; Andrews, J.; Brennan, S. [Stanford Synchrotron Radiation Lightsource, Stanford Linear Accelerator Center, Menlo Park, California (United States); Chu, Y. S. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois (United States)] (and others)

    2009-04-19T23:59:59.000Z

    X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

  9. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeedingBiomassPPPOPetroleum38 (1996)representativePolarized X-Rays

  10. Phase contrast tomography of the mouse cochlea at microfocus x-ray sources

    SciTech Connect (OSTI)

    Bartels, Matthias; Krenkel, Martin [Institute for X-Ray Physics, University of Göttingen, Göttingen (Germany)] [Institute for X-Ray Physics, University of Göttingen, Göttingen (Germany); Hernandez, Victor H. [InnerEarLab, Department of Otolaryngology, University Medical Center Göttingen, Göttingen (Germany) [InnerEarLab, Department of Otolaryngology, University Medical Center Göttingen, Göttingen (Germany); Bernstein Focus for Neurotechnology, University of Göttingen, Göttingen (Germany); Moser, Tobias [InnerEarLab, Department of Otolaryngology, University Medical Center Göttingen, Göttingen (Germany) [InnerEarLab, Department of Otolaryngology, University Medical Center Göttingen, Göttingen (Germany); Bernstein Focus for Neurotechnology, University of Göttingen, Göttingen (Germany); Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen (Germany); Salditt, Tim [Institute for X-Ray Physics, University of Göttingen, Göttingen (Germany) [Institute for X-Ray Physics, University of Göttingen, Göttingen (Germany); Center for Nanoscopy and Molecular Physiology of the Brain, Göttingen (Germany)

    2013-08-19T23:59:59.000Z

    We present phase contrast x-ray tomography of functional soft tissue within the bony cochlear capsule of mice, carried out at laboratory microfocus sources with well-matched source, detector, geometry, and reconstruction algorithms at spatial resolutions down to 2 ?m. Contrast, data quality and resolution enable the visualization of thin membranes and nerve fibers as well as automated segmentation of surrounding bone. By complementing synchrotron radiation imaging techniques, a broad range of biomedical applications becomes possible as demonstrated for optogenetic cochlear implant research.

  11. X-Ray Energy Responses of Silicon Tomography Detectors Irradiated with Fusion Produced Neutrons

    SciTech Connect (OSTI)

    Kohagura, J. [Plasma Research Centre, University of Tsukuba (Japan); Cho, T. [Plasma Research Centre, University of Tsukuba (Japan); Hirata, M. [Plasma Research Centre, University of Tsukuba (Japan); Numakura, T. [Plasma Research Centre, University of Tsukuba (Japan); Yokoyama, N. [Plasma Research Centre, University of Tsukuba (Japan); Fukai, T. [Plasma Research Centre, University of Tsukuba (Japan); Tomii, Y. [Plasma Research Centre, University of Tsukuba (Japan); Tokioka, S. [Plasma Research Centre, University of Tsukuba (Japan); Miyake, Y. [Plasma Research Centre, University of Tsukuba (Japan); Kiminami, S. [Plasma Research Centre, University of Tsukuba (Japan); Shimizu, K. [Plasma Research Centre, University of Tsukuba (Japan); Miyoshi, S. [Plasma Research Centre, University of Tsukuba (Japan); Hirano, K. [High Energy Accelerator Research Organization (Japan); Yoshida, M. [Japan Atomic Energy Research Institute (Japan); Yamauchi, M. [Japan Atomic Energy Research Institute (Japan); Kondoh, T. [Japan Atomic Energy Research Institute (Japan); Nishitani, T. [Japan Atomic Energy Research Institute (Japan)

    2005-01-15T23:59:59.000Z

    In order to clarify the effects of fusion-produced neutron irradiation on silicon semiconductor x-ray detectors, the x-ray energy responses of both n- and p-type silicon tomography detectors used in the Joint European Torus (JET) tokamak (n-type) and the GAMMA 10 tandem mirror (p-type) are studied using synchrotron radiation at the Photon Factory of the National Laboratory for High Energy Accelerator Research Organization (KEK). The fusion neutronics source (FNS) of Japan Atomic Energy Research Institute (JAERI) is employed as well-calibrated D-T neutron source with fluences from 10{sup 13} to 10{sup 15} neutrons/cm{sup 2} onto these semiconductor detectors. Different fluence dependence is found between these two types of detectors; that is, (i) for the n-type detector, the recovery of the degraded response is found after the neutron exposure beyond around 10{sup 13} neutrons/cm{sup 2} onto the detector. A further finding is followed as a 're-degradation' by a neutron irradiation level over about 10{sup 14} neutrons/cm{sup 2}. On the other hand, (ii) the energy response of the p-type detector shows only a gradual decrease with increasing neutron fluences. These properties are interpreted by our proposed theory on semiconductor x-ray responses in terms of the effects of neutrons on the effective doping concentration and the diffusion length of a semiconductor detector.

  12. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeedingBiomassPPPOPetroleum38 (1996)representativePolarized X-Rays Reveal

  13. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeedingBiomassPPPOPetroleum38 (1996)representativePolarized X-RaysPolarized

  14. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeedingBiomassPPPOPetroleum38 (1996)representativePolarizedPolarized X-Rays

  15. Postmortem analysis of sand grain crushing from pile interface using X-ray tomography

    SciTech Connect (OSTI)

    Silva, I. Matias; Combe, Gaeel; Foray, Pierre; Flin, Frederic; Lesaffre, Bernard [Universite de Grenoble, 3SR Lab, UMR 5521 Grenoble-INP, UJF-Grenoble 1, CNRS, Grenoble, France CEN, CNRM-GAME UMR 3589, Meteo France - CNRS, Grenoble (France)

    2013-06-18T23:59:59.000Z

    Pile foundations of offshore platforms, wind and water turbines are typically subjected to a variety of cyclic loading paths due to their complex environment. While many studies focus on global pile behaviour, the soil-pile interface is explored here by a micromechanical study of the soil layer in contact with the pile surface. This work is devoted to the analysis of frozen post-mortem silica sand samples recovered at the pile interface following installation and cyclic loading tests in a calibration chamber using x-ray tomography. An experimental procedure developed for three dimensional (3D) snow imaging was adapted for the recovery of the in-situ sand samples to preserve their structure during tomography scans. 3D images at a pixel size of 7 {mu}m were then obtained using a cryogenic cell. Results confirm the presence of a shear band at the pile surface as well as void ratios changes in the direction of the pile's radius.

  16. Bayesian soft X-ray tomography using non-stationary Gaussian Processes

    SciTech Connect (OSTI)

    Li, Dong; Svensson, J.; Thomsen, H.; Werner, A.; Wolf, R. [Max Planck Institute for Plasma Physics, Teilinstitut, D-17491 Greifswald (Germany)] [Max Planck Institute for Plasma Physics, Teilinstitut, D-17491 Greifswald (Germany); Medina, F. [Asociación EURATOM-CIEMAT, Madrid (Spain)] [Asociación EURATOM-CIEMAT, Madrid (Spain)

    2013-08-15T23:59:59.000Z

    In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods.

  17. Determination of Diffusion Profiles in Altered Wellbore Cement Using X-ray Computed Tomography Methods

    SciTech Connect (OSTI)

    Mason, Harris E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Walsh, Stuart D. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); DuFrane, Wyatt L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Carroll, Susan A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-06-17T23:59:59.000Z

    The development of accurate, predictive models for use in determining wellbore integrity requires detailed information about the chemical and mechanical changes occurring in hardened Portland cements. X-ray computed tomography (XRCT) provides a method that can nondestructively probe these changes in three dimensions. Here, we describe a method for extracting subvoxel mineralogical and chemical information from synchrotron XRCT images by combining advanced image segmentation with geochemical models of cement alteration. The method relies on determining “effective linear activity coefficients” (ELAC) for the white light source to generate calibration curves that relate the image grayscales to material composition. The resulting data set supports the modeling of cement alteration by CO2-rich brine with discrete increases in calcium concentration at reaction boundaries. The results of these XRCT analyses can be used to further improve coupled geochemical and mechanical models of cement alteration in the wellbore environment.

  18. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    SciTech Connect (OSTI)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01T23:59:59.000Z

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  19. Attenuation Correction of L-shell X-ray Fluorescence Computed Tomography Imaging

    E-Print Network [OSTI]

    Long, Liu; Bo, Ma; Qing, Xu; Lingtong, Yan; Li, Li; Songlin, Feng; Xiangqian, Feng

    2014-01-01T23:59:59.000Z

    X-ray Fluorescence Computed Tomography(XFCT) is a prevalent experimental technique which is utilized to investigate the spatial distribution of elements in sample. The sensitivity of L-shell XFCT of some elements is lower than that of K-shell XFCT. However, the image reconstruction for this technique has much more problems than that of transmission tomography, one of which is self-absorption. In the present work, a novel strategy was developed to deal with such problems. But few researches are concerned on attenuation correction of L-shell XFCT that are essential to get accurate reconstructed image. We make use of the known quantities and the unknown elemental concentration of interest to express the unknown attenuation maps. And then the attenuation maps are added in the contribution value of the pixel in MLEM reconstruction method. Results indicate that the relative error is less than 14.1%, which is proved this method can correct L-shell XFCT very well.

  20. Relationship of brain imaging with radionuclides and with x-ray computed tomography

    SciTech Connect (OSTI)

    Kuhl, D.E.

    1981-03-03T23:59:59.000Z

    Because of high sensitivity and specificity for altered local cerebral structure, x-ray computed tomography (CT) is the preferred initial diagnostic imaging study under most circumstances when cerebral disease is suspected. CT has no competitor for detecting fresh intracerebral hemorrhage. Radionuclide imaging (RN) scan is preferred when relative perfusion is to be assessed, in patients allergic to contrast media, and when an adequate CT study is not technically possible. (RN) plays an important complementary role to CT, especially for patients suspected of subacute or chronic subdura hematoma, cerebral infarction, arteriovenous malformations, meningitis, encephalitis, normal pressure hydrocephalus, or when CT findings are inconclusive. When CT is not available, RN serves as a good screening study for suspected cerebral tumor, infection, recent infarction, arteriovenous malformation, and chronic subdural hematoma. Future improvement in radionuclide imaging by means of emission composition potential. The compound plating approacl threshold for all the investigated transistors and fast neutron spectra lies within the raal. The value of the potential slightly changes with the coordinate change in this region, i.e. the charge on a collecting electrode is not practically guided up to a certain moment of time during the movement of nonequilibrium carriers.

  1. Data fusion in X-ray computed tomography using a superiorization approach

    SciTech Connect (OSTI)

    Schrapp, Michael J. [Siemens AG, CT Munich, Germany and Physics Department E21, Technical University of Munich, Munich (Germany)] [Siemens AG, CT Munich, Germany and Physics Department E21, Technical University of Munich, Munich (Germany); Herman, Gabor T. [Department of Computer Science, The Graduate Center, City University of New York, New York, New York 10016 (United States)] [Department of Computer Science, The Graduate Center, City University of New York, New York, New York 10016 (United States)

    2014-05-15T23:59:59.000Z

    X-ray computed tomography (CT) is an important and widespread inspection technique in industrial non-destructive testing. However, large-sized and heavily absorbing objects cause artifacts due to either the lack of penetration of the specimen in specific directions or by having data from only a limited angular range of views. In such cases, valuable information about the specimen is not revealed by the CT measurements alone. Further imaging modalities, such as optical scanning and ultrasonic testing, are able to provide data (such as an edge map) that are complementary to the CT acquisition. In this paper, a superiorization approach (a newly developed method for constrained optimization) is used to incorporate the complementary data into the CT reconstruction; this allows precise localization of edges that are not resolvable from the CT data by itself. Superiorization, as presented in this paper, exploits the fact that the simultaneous algebraic reconstruction technique (SART), often used for CT reconstruction, is resilient to perturbations; i.e., it can be modified to produce an output that is as consistent with the CT measurements as the output of unmodified SART, but is more consistent with the complementary data. The application of this superiorized SART method to measured data of a turbine blade demonstrates a clear improvement in the quality of the reconstructed image.

  2. Synchrotron-based imaging and tomography with hard X-rays C. Rau a,b,c,e,*, V. Crecea a,d

    E-Print Network [OSTI]

    Braun, Paul

    Synchrotron-based imaging and tomography with hard X-rays C. Rau a,b,c,e,*, V. Crecea a,d , W. Liu, 33501 Bielefeld, Germany h BESSY GmbH, Albert-Einstein-Str.15, 12489 Berlin, Germany i Department Hard X-ray imaging with synchrotron radiation is a powerful tool to study opaque materials on the micro

  3. Information-theoretic discrepancy based iterative reconstructions (IDIR) for polychromatic x-ray tomography

    SciTech Connect (OSTI)

    Jang, Kwang Eun; Lee, Jongha; Sung, Younghun; Lee, SeongDeok [Advanced Media Laboratory, Samsung Advanced Institute of Technology (SAIT), San 14, Nongseo Dong, Giheung Gu, Yongin, Gyeonggi 446-712 (Korea, Republic of)] [Advanced Media Laboratory, Samsung Advanced Institute of Technology (SAIT), San 14, Nongseo Dong, Giheung Gu, Yongin, Gyeonggi 446-712 (Korea, Republic of)

    2013-09-15T23:59:59.000Z

    Purpose: X-ray photons generated from a typical x-ray source for clinical applications exhibit a broad range of wavelengths, and the interactions between individual particles and biological substances depend on particles' energy levels. Most existing reconstruction methods for transmission tomography, however, neglect this polychromatic nature of measurements and rely on the monochromatic approximation. In this study, we developed a new family of iterative methods that incorporates the exact polychromatic model into tomographic image recovery, which improves the accuracy and quality of reconstruction.Methods: The generalized information-theoretic discrepancy (GID) was employed as a new metric for quantifying the distance between the measured and synthetic data. By using special features of the GID, the objective function for polychromatic reconstruction which contains a double integral over the wavelength and the trajectory of incident x-rays was simplified to a paraboloidal form without using the monochromatic approximation. More specifically, the original GID was replaced with a surrogate function with two auxiliary, energy-dependent variables. Subsequently, the alternating minimization technique was applied to solve the double minimization problem. Based on the optimization transfer principle, the objective function was further simplified to the paraboloidal equation, which leads to a closed-form update formula. Numerical experiments on the beam-hardening correction and material-selective reconstruction were conducted to compare and assess the performance of conventional methods and the proposed algorithms.Results: The authors found that the GID determines the distance between its two arguments in a flexible manner. In this study, three groups of GIDs with distinct data representations were considered. The authors demonstrated that one type of GIDs that comprises “raw” data can be viewed as an extension of existing statistical reconstructions; under a particular condition, the GID is equivalent to the Poisson log-likelihood function. The newly proposed GIDs of the other two categories consist of log-transformed measurements, which have the advantage of imposing linearized penalties over multiple discrepancies. For all proposed variants of the GID, the aforementioned strategy was used to obtain a closed-form update equation. Even though it is based on the exact polychromatic model, the derived algorithm bears a structural resemblance to conventional methods based on the monochromatic approximation. The authors named the proposed approach as information-theoretic discrepancy based iterative reconstructions (IDIR). In numerical experiments, IDIR with raw data converged faster than previously known statistical reconstruction methods. IDIR with log-transformed data exhibited superior reconstruction quality and faster convergence speed compared with conventional methods and their variants.Conclusions: The authors' new framework for tomographic reconstruction allows iterative inversion of the polychromatic data model. The primary departure from the traditional iterative reconstruction was the employment of the GID as a new metric for quantifying the inconsistency between the measured and synthetic data. The proposed methods outperformed not only conventional methods based on the monochromatic approximation but also those based on the polychromatic model. The authors have observed that the GID is a very flexible means to design an objective function for iterative reconstructions. Hence, the authors expect that the proposed IDIR framework will also be applicable to other challenging tasks.

  4. atf compton x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    D; Fritzsche, S 2014-01-01 14 Photospheres, Comptonization and X-ray Lines in Gamma Ray Bursts Astrophysics (arXiv) Summary: Steep X-ray spectral slopes, X-ray excesses and...

  5. adc x-ray binary: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    systems. Sudip Bhattacharyya 2010-02-24 17 X-ray Transients from X-ray Binaries to Gamma Ray Bursts CERN Preprints Summary: We discuss three classes of x-ray transients to...

  6. Experimental comparison of grating- and propagation-based hard X-ray phase tomography of soft tissue

    SciTech Connect (OSTI)

    Lang, S.; Schulz, G.; Müller, B. [Biomaterials Science Center, University of Basel, Basel (Switzerland); Zanette, I., E-mail: irene.zanette@tum.de [Physik-Department und Institut für Medizintechnik, Technische Universität München, Garching (Germany); European Synchrotron Radiation Facility, Grenoble (France); Dominietto, M. [Biomaterials Science Center, University of Basel, Basel (Switzerland); Institute for Biomedical Engineering, ETH Zürich, Zürich (Switzerland); Langer, M. [European Synchrotron Radiation Facility, Grenoble (France); Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-LYON, Université de Lyon 1, Villeurbane (France); Rack, A.; Le Duc, G. [European Synchrotron Radiation Facility, Grenoble (France); David, C. [Laboratory for Micro- and Nanotechnology, Paul Scherrer Institut, Villigen (Switzerland); Mohr, J. [Institute of Microstructure Technology, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen (Germany); Pfeiffer, F. [Physik-Department und Institut für Medizintechnik, Technische Universität München, Garching (Germany); Weitkamp, T. [European Synchrotron Radiation Facility, Grenoble (France); Synchrotron Soleil, Gif-sur-Yvette (France)

    2014-10-21T23:59:59.000Z

    When imaging soft tissues with hard X-rays, phase contrast is often preferred over conventional attenuation contrast due its superior sensitivity. However, it is unclear which of the numerous phase tomography methods yields the optimized results at given experimental conditions. Therefore, we quantitatively compared the three phase tomography methods implemented at the beamline ID19 of the European Synchrotron Radiation Facility: X-ray grating interferometry (XGI), and propagation-based phase tomography, i.e., single-distance phase retrieval (SDPR) and holotomography (HT), using cancerous tissue from a mouse model and an entire heart of a rat. We show that for both specimens, the spatial resolution derived from the characteristic morphological features is about a factor of two better for HT and SDPR compared to XGI, whereas the XGI data generally exhibit much better contrast-to-noise ratios for the anatomical features. Moreover, XGI excels in fidelity of the density measurements, and is also more robust against low-frequency artifacts than HT, but it might suffer from phase-wrapping artifacts. Thus, we can regard the three phase tomography methods discussed as complementary. The application will decide which spatial and density resolutions are desired, for the imaging task and dose requirements, and, in addition, the applicant must choose between the complexity of the experimental setup and the one of data processing.

  7. Pressurized subsampling system for pressured gas-hydrate-bearing sediment: Microscale imaging using X-ray computed tomography

    SciTech Connect (OSTI)

    Jin, Yusuke, E-mail: u-jin@aist.go.jp; Konno, Yoshihiro; Nagao, Jiro [Production Technology Team, Methane Hydrate Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Sapporo 062-8517 (Japan)

    2014-09-01T23:59:59.000Z

    A pressurized subsampling system was developed for pressured gas hydrate (GH)-bearing sediments, which have been stored under pressure. The system subsamples small amounts of GH sediments from cores (approximately 50 mm in diameter and 300 mm in height) without pressure release to atmospheric conditions. The maximum size of the subsamples is 12.5 mm in diameter and 20 mm in height. Moreover, our system transfers the subsample into a pressure vessel, and seals the pressure vessel by screwing in a plug under hydraulic pressure conditions. In this study, we demonstrated pressurized subsampling from artificial xenon-hydrate sediments and nondestructive microscale imaging of the subsample, using a microfocus X-ray computed tomography (CT) system. In addition, we estimated porosity and hydrate saturation from two-dimensional X-ray CT images of the subsamples.

  8. Tensile testing of materials at high temperatures above 1700?°C with in situ synchrotron X-ray micro-tomography

    SciTech Connect (OSTI)

    Haboub, Abdel; Nasiatka, James R.; MacDowell, Alastair A. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Bale, Hrishikesh A. [Department of Materials Science and Engineering, University of California, Berkeley, California 94720 (United States); Cox, Brian N.; Marshall, David B. [Teledyne Scientific Company, Thousand Oaks, California 91360 (United States); Ritchie, Robert O., E-mail: roritchie@lbl.gov [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Department of Materials Science and Engineering, University of California, Berkeley, California 94720 (United States)

    2014-08-15T23:59:59.000Z

    A compact ultrahigh temperature tensile testing instrument has been designed and fabricated for in situ x-ray micro-tomography using synchrotron radiation at the Advanced Light Source, Lawrence Berkeley National Laboratory. It allows for real time x-ray micro-tomographic imaging of test materials under mechanical load at temperatures up to 2300?°C in controlled environments (vacuum or controlled gas flow). Sample heating is by six infrared halogen lamps with ellipsoidal reflectors arranged in a confocal configuration, which generates an approximately spherical zone of high heat flux approximately 5 mm in diameter. Samples are held between grips connected to a motorized stage that loads the samples in tension or compression with forces up to 2.2 kN. The heating chamber and loading system are water-cooled for thermal stability. The entire instrument is mounted on a rotation stage that allows stepwise recording of radiographs over an angular range of 180°. A thin circumferential (360°) aluminum window in the wall of the heating chamber allows the x-rays to pass through the chamber and the sample over the full angular range. The performance of the instrument has been demonstrated by characterizing the evolution of 3D damage mechanisms in ceramic composite materials under tensile loading at 1750?°C.

  9. Laboratory-Based Cryogenic Soft X-ray Tomography with Correlative Cryo-Light and Electron Microscopy

    SciTech Connect (OSTI)

    Carlson, David B.; Gelb, Jeff; Palshin, Vadim; Evans, James E.

    2013-02-01T23:59:59.000Z

    Here we present a novel laboratory-based cryogenic soft X-ray microscope for whole cell tomography of frozen hydrated samples. We demonstrate the capabilities of this compact cryogenic microscope by visualizing internal sub-cellular structures of Saccharomyces cerevisiae cells. The microscope is shown to achieve better than 50 nm spatial resolution with a Siemens star test sample. For whole biological cells, the microscope can image specimens up to 5 micrometers thick. Structures as small as 90 nm can be detected in tomographic reconstructions at roughly 70 nm spatial resolution following a low cumulative radiation dose of only 7.2 MGy. Furthermore, the design of the specimen chamber utilizes a standard sample support that permits multimodal correlative imaging of the exact same unstained yeast cell via cryo-fluorescence light microscopy, cryo-soft x-ray microscopy and cryo-transmission electron microscopy. This completely laboratory-based cryogenic soft x-ray microscope will therefore enable greater access to three-dimensional ultrastructure determination of biological whole cells without chemical fixation or physical sectioning.

  10. alpha particle x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of X-rays from the Sun direction beyond the limb with a characteristic radial distribution. These X-rays should be observed more easily during periods of quiet Sun. An...

  11. E-Print Network 3.0 - aspect ratio x-ray Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    0953-89841825S17 Summary: the power ratio of beam splitting. With centralized remote control, heating and x-ray diffraction... for in situ x-ray diffraction at high...

  12. atmospheric electron-induced x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    opacity to X-rays, and the wind flow parameters, such as mass loss rate and terminal speed. L. M. Oskinova; R. Ignace; J. C. Brown; J. P. Cassinelli 2001-04-25 5 Hard X-ray...

  13. all-sky hard x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    sky coverage each orbit, and full sky coverage each 50 days, hard x-ray studies of gamma-ray bursts, AGN, galactic transients, x-ray binaries and accretion-powered pulsars can be...

  14. all-sky x-ray image: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    sky coverage each orbit, and full sky coverage each 50 days, hard x-ray studies of gamma-ray bursts, AGN, galactic transients, x-ray binaries and accretion-powered pulsars can be...

  15. angle x-ray sky: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Astrophysics (arXiv) Summary: We describe a search for X-ray afterglows from gamma-ray bursts using the ROSAT all-sky survey (RASS) data. If the emission in the soft X-ray...

  16. E-Print Network 3.0 - astronomical hard x-ray Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    search results for: astronomical hard x-ray Page: << < 1 2 3 4 5 > >> 1 Reverse Drift Bursts in the 0.8-4.5 GHz Band and their Relation to X-Rays Summary: and causing radio...

  17. E-Print Network 3.0 - attosecond kev x-ray Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    de Montral Collection: Engineering 3 Generation of Attosecond X-ray and gamma-ray via Compton backscattering Summary: Generation of Attosecond X-ray and gamma-ray via...

  18. accretion-powered millisecond x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SAX J1808.4-3658, which also makes this the first X-ray pulsar which exhibits thermonuclear X-ray bursts. Rudy Wijnands; Michiel van der Klis 1998-04-21 2 Timing of the first...

  19. accreting millisecond x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SAX J1808.4-3658, which also makes this the first X-ray pulsar which exhibits thermonuclear X-ray bursts. Rudy Wijnands; Michiel van der Klis 1998-04-21 4 Search for...

  20. Characterizing Three-Dimensional Textile Ceramic Composites Using Synchrotron X-Ray Micro-Computed-Tomography

    E-Print Network [OSTI]

    Ritchie, Robert

    , Thousand Oaks, CA 91360 Three-dimensional (3-D) images of two ceramic-matrix textile composites were studied represent a new class of integrally woven ceramic matrix composites for high-temperature appliCharacterizing Three-Dimensional Textile Ceramic Composites Using Synchrotron X-Ray Micro

  1. Apparatus for X-ray diffraction microscopy and tomography of cryo specimens

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Beetz, T.; Howells, M. R.; Jacobsen, C.; Kao, C. -C.; Kirz, J.; Lima, E.; Mentes, T. O.; Miao, H.; Sanchez-Hanke, C.; Sayre, D.; et al

    2005-06-01T23:59:59.000Z

    An apparatus for diffraction microscopy of biological and materials science specimens is described. In this system, a coherent soft X-ray beam is selected with a pinhole, and the illuminated specimen is followed by an adjustable beamstop and CCD camera to record diffraction data from non-crystalline specimens. In addition, a Fresnel zone plate can be inserted to allow for direct imaging. The system makes use of a cryogenic specimen holder with cryotransfer capabilities to allow frozen hydrated specimens to be loaded. The specimen can be tilted over a range of ± 80 ° degrees for three-dimensional imaging; this is done bymore »computer-controlled motors, enabling automated alignment of the specimen through a tilt series. The system is now in use for experiments in soft X-ray diffraction microscopy.« less

  2. Apparatus for X-ray diffraction microscopy and tomography of cryo specimens

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Beetz, T.; Howells, M.R.; Jacobsen, C.; Kao, C.-C.; Kirz, J.; Lima, E.; Mentes, T.O.; Miao, H.; Sanchez-Hanke, C.; Sayre, D.; Shapiro, D.

    2005-06-01T23:59:59.000Z

    An apparatus for diffraction microscopy of biological and materials science specimens is described. In this system, a coherent soft X-ray beam is selected with a pinhole, and the illuminated specimen is followed by an adjustable beamstop and CCD camera to record diffraction data from non-crystalline specimens. In addition, a Fresnel zone plate can be inserted to allow for direct imaging. The system makes use of a cryogenic specimen holder with cryotransfer capabilities to allow frozen hydrated specimens to be loaded. The specimen can be tilted over a range of +/- 80 degrees for three-dimensional imaging; this is done by computer-controlled motors, enabling automated alignment of the specimen through a tilt series. The system is now in use for experiments in soft X-ray diffraction microscopy.

  3. Apparatus for X-ray diffraction microscopy and tomography of cryo specimens

    SciTech Connect (OSTI)

    Beetz, T. [Stony Brook Univ., Stony Brook, NY (United States); Howells, M. R. [Brookhaven National Laboratory (BNL), Upton, NY (United States). National Synchrotron Light Source; Brookhaven National Laboratory (BNL), Upton, NY (United States). Center for Functional Nanomaterials; Jacobsen, C. [Stony Brook Univ., Stony Brook, NY (United States); Kao, C. -C. [Brookhaven National Laboratory (BNL), Upton, NY (United States). National Synchrotron Light Source; Kirz, J. [Stony Brook Univ., Stony Brook, NY (United States); Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Advanced Light Source; Lima, E. [Stony Brook Univ., Stony Brook, NY (United States); Mentes, T. O. [Stony Brook Univ., Stony Brook, NY (United States); TASC-INFM National Lab, Trieste (Italy); Miao, H. [Stony Brook Univ., Stony Brook, NY (United States); Sanchez-Hanke, C. [Brookhaven National Laboratory (BNL), Upton, NY (United States). National Synchrotron Light Source; Sayre, D. [Stony Brook Univ., Stony Brook, NY (United States); Shapiro, D. [Stony Brook Univ., Stony Brook, NY (United States)

    2005-06-01T23:59:59.000Z

    An apparatus for diffraction microscopy of biological and materials science specimens is described. In this system, a coherent soft X-ray beam is selected with a pinhole, and the illuminated specimen is followed by an adjustable beamstop and CCD camera to record diffraction data from non-crystalline specimens. In addition, a Fresnel zone plate can be inserted to allow for direct imaging. The system makes use of a cryogenic specimen holder with cryotransfer capabilities to allow frozen hydrated specimens to be loaded. The specimen can be tilted over a range of ± 80 ° degrees for three-dimensional imaging; this is done by computer-controlled motors, enabling automated alignment of the specimen through a tilt series. The system is now in use for experiments in soft X-ray diffraction microscopy.

  4. Installation of soft X-ray array diagnostics and its application to tomography reconstruction using synthetic KSTAR X-ray images

    SciTech Connect (OSTI)

    Lee, Seung Hun; Jang, Juhyeok; Hong, Joohwan; Jang, Siwon; Choe, Wonho, E-mail: wchoe@kaist.ac.kr [Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of); Impurity and Edge Research Center, Daejeon 305-701 (Korea, Republic of); Pacella, D.; Romano, A.; Gabellieri, L. [Associazione Euratom-ENEA sulla Fusione, C.R. Frascati 00044 (Italy); Kim, Junghee [National Fusion Research Institute, Daejeon 305-806 (Korea, Republic of); Major of Nuclear Fusion and Plasma Science Department, Korea University of Science and Technology, Daejeon 305-350 (Korea, Republic of)

    2014-11-15T23:59:59.000Z

    Four-array system of soft X-ray diagnostics was installed on KSTAR tokamak. Each array has 32 viewing chords of two photo-diode array detectors with spatial resolution of 2 cm. To estimate signals from the soft X-ray radiation power, typical n{sub e}, T{sub e}, and argon impurity line radiation profiles in KSTAR are chosen. The photo-diodes were absolutely calibrated as a function of the incident photon energy in 2–40 keV range with a portable X-ray tube. Two-dimensional T{sub e} image properties by multi-energy method were simulated and visualized with six combinations of beryllium filter sets within the dynamic range of signal ratio.

  5. E-Print Network 3.0 - accreting x-ray neutron Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (Ohio University, USA), George Pavlov Summary: accretion in a binary system, thermonuclear reactions occurring at the surface induce x-ray bursts... on the constituents of...

  6. advanced x-ray techniques: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    a new X-ray radiographic technique for measuring density uniformity of silica aerogels used as radiator in proximity-focusing ring-imaging Cherenkov detectors. To obtain...

  7. Permeability of laboratory-formed methane-hydrate-bearing sand: Measurements and observations using x-ray computed tomography

    SciTech Connect (OSTI)

    Kneafsey, T. J.; Seol, Y.; Gupta, A.; Tomutsa, L.

    2010-09-15T23:59:59.000Z

    Methane hydrate was formed in two moist sands and a sand/silt mixture under a confining stress in an X-ray-transparent pressure vessel. Three initial water saturations were used to form three different methane-hydrate saturations in each medium. X-ray computed tomography (CT) was used to observe location-specific density changes caused by hydrate formation and flowing water. Gas-permeability measurements in each test for the dry, moist, frozen, and hydrate-bearing states are presented. As expected, the effective permeabilities (intrinsic permeability of the medium multiplied by the relative permeability) of the moist sands decreased with increasing moisture content. In a series of tests on a single sample, the effective permeability typically decreased as the pore space became more filled, in the order of dry, moist, frozen, and hydrate-bearing. In each test, water was flowed through the hydrate-bearing medium and we observed the location-specific changes in water saturation using CT scanning. We compared our data to a number of models, and our relative permeability data compare most favorably with models in which hydrate occupies the pore bodies rather than the pore throats. Inverse modeling (using the data collected from the tests) will be performed to extend the relative permeability measurements.

  8. Statistical models and regularization strategies in statistical image reconstruction of low-dose X-ray computed tomography: a survey

    E-Print Network [OSTI]

    Zhang, Hao; Ma, Jianhua; Lu, Hongbing; Liang, Zhengrong

    2014-01-01T23:59:59.000Z

    Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose X-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method for various clinical tasks. According to the maximum a posterior (MAP) estimation, the SIR methods can be typically formulated by an objective function consisting of two terms: (1) data-fidelity (or equivalently, data-fitting or data-mismatch) term modeling the statistics of projection measurements, and (2) regularization (or equivalently, prior or penalty) term reflecting prior knowledge or expectation on the characteristics of the image to be reconstructed. Existing SIR methods for low-dose CT can be divided into two groups: (1) those that use calibrated transmitted photon counts (before log-transform) with penalized maximum likelihood (pML) criterion, and (2) those that use calibrated line-integrals (after log-transform) with penalized weighted least-squares (PWLS) criterion. Accurate s...

  9. Investigation of measuring hazardous substances in printed circuit boards using the micro-focus X-ray fluorescence screening

    E-Print Network [OSTI]

    Fu, M L; Fakhrtdinov, R; Grigoriev, M; Quan, B S; Le, Z C; Roshchupkin, D

    2014-01-01T23:59:59.000Z

    Printed circuit boards (PCBs) are widely used in most electrical and electronic equipments or products. Hazardous substances such as Pb, Hg, Cd, etc, can be present in high concentrations in PCBs and the degradation and release of these substances poses a huge threat to humans and the environment. To investigation the chemical composition of PCBs in domestic market of China, a practical micro-focus X-ray fluorescence system is setup to make the elements analysis, especially for detecting hazardous substances. Collimator is adopted to focus the X-ray emitted from X-ray tube. BRUKER X-ray detector with proportional counter is used to detect the emitted fluorescence from the PCB samples. Both single layer PCB samples and double layers PCB samples made of epoxy glass fiber are purchased from the domestic market of China. Besides, a MC55 wireless communication module made by SIEMENS in Germany is used as the reference material. Experimental results from the fluorescence spectrums of the testing points of PCB sampl...

  10. angle x-ray absorption: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    angle x-ray absorption First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Time Resolved X-Ray Absorption...

  11. The influence of glass fibers on elongational viscosity studied by means of optical coherence tomography and X-ray computed tomography

    SciTech Connect (OSTI)

    Aigner, M., E-mail: michael.aigner@jku.at; Köpplmayr, T., E-mail: thomas.koepplmayr@jku.at, E-mail: Christian.lang@jku.at; Lang, C., E-mail: thomas.koepplmayr@jku.at, E-mail: Christian.lang@jku.at; Burzic, I., E-mail: ivana.burzic@jku.at, E-mail: juergen.miethlinger@jku.at; Miethlinger, J., E-mail: ivana.burzic@jku.at, E-mail: juergen.miethlinger@jku.at [Institute of Polymer Extrusion and Compounding, Johannes Kepler University Linz (Austria); Salaberger, D., E-mail: dietmar.salaberger@fh-wels.at [University of Applied Sciences Upper Austria (Austria); Buchsbaum, A., E-mail: andreas.buchsbaum@recendt.at; Leitner, M. [Research Center for Non Destructive Testing GmbH (Austria); Heise, B., E-mail: bettina.heise@jku.at [Christian Doppler Laboratory for Microscopic and Spectroscopic Material Characterization, ZONA, Austria and Institute for Knowledge-based Mathematical Systems, Johannes Kepler University Linz (Austria); Schausberger, S. E., E-mail: stefan.schausberger@jku.at; Stifter, D. [Christian Doppler Laboratory for Microscopic and Spectroscopic Material Characterization, ZONA (Austria)

    2014-05-15T23:59:59.000Z

    We report on the flow characteristics of glass-fiber-reinforced polymers in elongational rheometry. Unlike polymers with geometrically isotropic fillers, glass-fiber-reinforced polymers exhibit flow behavior and rheology that depend heavily on the orientation, the length distribution and the content of the fibers. One of the primary objectives of this study was to determine the effect of fiber orientation, concentration and distribution on the entrance pressure drop by means of optical coherence tomography (OCT), full-field optical coherence microscopy (FF-OCM), and X-ray computed tomography (X-CT). Both pressure drop and melt flow were analyzed using a special elongation die (Thermo Scientific X-Die [3]) for inline measurements. Samples with a variety of fiber volume fractions, fiber lengths and processing temperatures were measured.

  12. Noninvasive Monitoring of Local Drug Release Using X-ray Computed Tomography: Optimization and

    E-Print Network [OSTI]

    Gao, Jinming

    -performanceliquidchromatography(HPLC), high resolution mass spectrometry, or atomic absorption spectrometry (AAS). These procedures,3 Gamma-emission imaging, positron- emission tomography (PET), and magnetic reso- nance imaging (MRI of these methods are rela- tively low spatial resolution (5 and 10 mm for clinical gamma imaging and PET

  13. The Cambrian Evolutionary Explosion: Novel Evidence from Fossils Studied by X-ray Tomography

    SciTech Connect (OSTI)

    Chen, Jun-Yuan (Nanjing University, China) [Nanjing University, China

    2011-06-01T23:59:59.000Z

    The Cambrian explosion (from 542 million years to 488 million years ago) is one of the greatest mysteries in evolutionary biology. It wasn't until this period that complex organisms became common and diverse. the magnitude of the event can be understood based on the contrast between the biota and the degree of diversity of the fossils from both sides. great advances have been made in Cambrian palaeontology over the past century, especially the discovery of the well-preserved soft-bodied fauna from the Middle Cambrian Burgess Shale and the Lower Cambrian Maotianshan Shale deposits. The Cambrian side of the "Cambrian explosion" is richly illustrated and contrasts greatly with the Precambrian side. The study of these extraordinarily preserved fossil biota is extremely difficult. A major challenge is 3-D reconstruction and determining the patter of the cell organization in Weng'an embryos and their buried structures in Maotianshan Shale fossils. This talk will show that two recent technological approaches, propagation phase contrast synchrotron x-ray microtomography and microtomography, provide unique analytical tools that permit the nondestructive computational examination and visualization of the internal and buried characters in virtual sections in any plane, and virtual 3-D depictions of internal structures.

  14. anomalous x-ray pulsars: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  15. anomalous x-ray scattering: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  16. analyzing x-ray pulsar: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  17. anomalous x-ray fluorescence: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  18. anomalous small-angle x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  19. anomalous surface x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  20. anomalous x-ray diffraction: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  1. anomalous x-ray pulsar: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from the soft X-rays emitted by the neutron-star surface. The relation between these heating rates and measured near-infrared fluxes in the K and Ks bands places severe...

  2. ambient-pressure x-ray photoelectron: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    are placed to face the fan-beam plane and directly measure x-ray fluorescence data. Detector elements are so collimated that each element only sees a unique area element on...

  3. annealing x-ray investigations: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Institute of Physics 17 Investigation the connection between the intermediate gamma-ray bursts and X-ray flashes CERN Preprints Summary: Gamma-ray bursts can be divided into...

  4. airborne lead x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    instance Sparks, Donald L. 2 Alignment in Gamma-Hadron Families Detected by Deep Lead X-Ray Emulsion Chambers HEP - Phenomenology (arXiv) Summary: Alignment of main fluxes of...

  5. accurate x-ray scattering: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    is ove... Corrales, Lia 2012-01-01 20 Dust scattering X-ray expanding rings around gamma-ray bursts Astrophysics (arXiv) Summary: Scattering by dust grains in our Galaxy can...

  6. ambient pressure x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    is a well studied subject. Loose groups with diffuse X-ray emmision from the intragroup medium (IGM) offer an intermediate environment between clusters and groups without a hot...

  7. acute x-ray exposure: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    are more sensitive to both X-ray and heavy ion exposure than to high-LET radiation damage. Mice haplodeficient for the ATM gene and wildtypes were exposed to 325 m that not...

  8. Imaging Antifungal Drug Molecules in Action using Soft X-Ray Tomography

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC) EnvironmentalGyroSolé(tm)Hydrogen StorageITERITERBuilding EnergyImaging PrintImaging

  9. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-Ray Imaging in Reflection Print The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field of lensless imaging. XFELs...

  10. Fuel Injection and Spray Research Using X-Ray Diagnostics

    Broader source: Energy.gov (indexed) [DOE]

    by ECN using several different techniques - Silicone molds (Valencia) - X-ray absorption tomography (CAT) - X-Ray phase contrast imaging (Argonne) - Microscopy (Sandia) ...

  11. Stabilizing dual-energy X-ray computed tomography reconstructions using patch-based regularization

    E-Print Network [OSTI]

    Tracey, Brian H

    2014-01-01T23:59:59.000Z

    Recent years have seen growing interest in exploiting dual- and multi-energy measurements in computed tomography (CT) in order to characterize material properties as well as object shape. Material characterization is performed by decomposing the scene into constitutive basis functions, such as Compton scatter and photoelectric absorption functions. While well motivated physically, the joint recovery of the spatial distribution of photoelectric and Compton properties is severely complicated by the fact that the data are several orders of magnitude more sensitive to Compton scatter coefficients than to photoelectric absorption, so small errors in Compton estimates can create large artifacts in the photoelectric estimate. To address these issues, we propose a model-based iterative approach which uses patch-based regularization terms to stabilize inversion of photoelectric coefficients, and solve the resulting problem though use of computationally attractive Alternating Direction Method of Multipliers (ADMM) solu...

  12. Response Time Measurements of the NIF DANTE XRD-31 X-Ray Diodes (Pre-print)

    SciTech Connect (OSTI)

    Don Pellinen and Michael Griffin

    2009-01-23T23:59:59.000Z

    The XRD-31 is a fast, windowless X-ray vacuum photodiode developed by EG&G. It is currently the primary fast X-ray detector used to diagnose the X-rays on NIF and OMEGA on the multichannel DANTE spectrometer. The XRD-31 has a dynamic range of less than 1e-12 amps to more than 10 amps. A technique is described to measure the impulse response of the diodes to a 150 fs pulse of 200 nm laser light and a method to calculate the “risetime” for a square pulse and compare it with the computed electron transit time from the photocathode to the anode. Measured response time for 5 XRD-31s assembled in early 2004 was 149.7 ps +-2.75 ps.

  13. X-ray computed-tomography observations of water flow through anisotropic methane hydrate-bearing sand

    SciTech Connect (OSTI)

    Seol, Yongkoo; Kneafsey, Timothy J.

    2009-06-01T23:59:59.000Z

    We used X-ray computed tomography (CT) to image and quantify the effect of a heterogeneous sand grain-size distribution on the formation and dissociation of methane hydrate, as well as the effect on water flow through the heterogeneous hydrate-bearing sand. A 28 cm long sand column was packed with several segments having vertical and horizontal layers with sands of different grain-size distributions. During the hydrate formation, water redistribution occurred. Observations of water flow through the hydrate-bearing sands showed that water was imbibed more readily into the fine sand, and that higher hydrate saturation increased water imbibition in the coarse sand due to increased capillary strength. Hydrate dissociation induced by depressurization resulted in different flow patterns with the different grain sizes and hydrate saturations, but the relationships between dissociation rates and the grain sizes could not be identified using the CT images. The formation, presence, and dissociation of hydrate in the pore space dramatically impact water saturation and flow in the system.

  14. alxga1-xas high-energy x-ray: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    alxga1-xas high-energy x-ray First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 ?????? ??? ??...

  15. Design of Mega-Voltage X-ray Digital Radiography and Computed Tomography Performance Phantoms

    SciTech Connect (OSTI)

    Aufderheide, M B; Martz, H E; Curtin, M

    2009-06-22T23:59:59.000Z

    A number of fundamental scientific questions have arisen concerning the operation of high-energy DR and CT systems. Some of these questions include: (1) How deeply can such systems penetrate thickly shielded objects? (2) How well can such systems distinguish between dense and relatively high Z materials such as lead, tungsten and depleted uranium and lower Z materials such as steel, copper and tin? (3) How well will such systems operate for a uranium material which is an intermediate case between low density yellowcake and high density depleted uranium metal? These questions have led us to develop a set of phantoms to help answer these questions, but do not have any direct bearing on any smuggling concern. These new phantoms are designed to allow a systemic exploration of these questions by gradually varying their compositions and thicknesses. These phantoms are also good probes of the blurring behavior of radiography and tomography systems. These phantoms are composed of steel ({rho} assumed to be 7.8 g/cc), lead ({rho} assumed to be 11.4 g/cc), tungsten ({rho} assumed to be 19.25 g/cc), uranium oxide (UO{sub 3}) ({rho} assumed to be 4.6 g/cc), and depleted uranium (DU) ({rho} assumed to be 18.9 g/cc). There are five designed phantoms described in this report: (1) Cylindrical shells of Tungsten and Steel; (2) Depleted Uranium Inside Tungsten Hemi-cube Shells; (3) Nested Spherical Shells; (4) UO{sub 3} Cylinder; and (5) Shielded DU Sphere.

  16. In Situ X-Ray Scattering Helps Optimize Printed Solar Cells

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC) EnvironmentalGyroSolé(tm)HydrogenRFP » Important TrinityEnergyIn Situ X-Ray

  17. In Situ X-Ray Scattering Helps Optimize Printed Solar Cells

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC) EnvironmentalGyroSolé(tm)HydrogenRFP » Important TrinityEnergyIn Situ X-RayIn

  18. In Situ X-Ray Scattering Helps Optimize Printed Solar Cells

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC) EnvironmentalGyroSolé(tm)HydrogenRFP » Important TrinityEnergyIn Situ X-RayInIn

  19. Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom

    SciTech Connect (OSTI)

    Moyers, M. F., E-mail: MFMoyers@roadrunner.com [Shanghai Proton and Heavy Ion Center, Shanghai, China 201321 (China)

    2014-06-15T23:59:59.000Z

    Purpose: Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCTNs) to relative linear stopping powers (RLSPs). Various facilities engaged in multi-institutional clinical trials involving proton beams have been applying significantly different margins in their patient planning. This study was performed to determine the variance in the conversion functions used at proton facilities in the U.S.A. wishing to participate in National Cancer Institute sponsored clinical trials. Methods: A simplified method of determining the conversion function was developed using a standard phantom containing only water and aluminum. The new method was based on the premise that all scanners have their XCTNs for air and water calibrated daily to constant values but that the XCTNs for high density/high atomic number materials are variable with different scanning conditions. The standard phantom was taken to 10 different proton facilities and scanned with the local protocols resulting in 14 derived conversion functions which were compared to the conversion functions used at the local facilities. Results: For tissues within ±300 XCTN of water, all facility functions produced converted RLSP values within ±6% of the values produced by the standard function and within 8% of the values from any other facility's function. For XCTNs corresponding to lung tissue, converted RLSP values differed by as great as ±8% from the standard and up to 16% from the values of other facilities. For XCTNs corresponding to low-density immobilization foam, the maximum to minimum values differed by as much as 40%. Conclusions: The new method greatly simplifies determination of the conversion function, reduces ambiguity, and in the future could promote standardization between facilities. Although it was not possible from these experiments to determine which conversion function is most appropriate, the variation between facilities suggests that the margins used in some facilities to account for the uncertainty in converting XCTNs to RLSPs may be too small.

  20. Note: Design and construction of a multi-scale, high-resolution, tube-generated X-Ray computed-tomography system for three-dimensional (3D) imaging

    SciTech Connect (OSTI)

    Mertens, J. C. E.; Williams, J. J.; Chawla, Nikhilesh [Materials Science and Engineering, Security and Defense Systems Initiative, Arizona State University, 781 E. Terrace Road, ISTB4, Tempe, Arizona 85287-5604 (United States)] [Materials Science and Engineering, Security and Defense Systems Initiative, Arizona State University, 781 E. Terrace Road, ISTB4, Tempe, Arizona 85287-5604 (United States)

    2014-01-15T23:59:59.000Z

    The design and construction of a high resolution modular x-ray computed tomography (XCT) system is described. The approach for meeting a specified set of performance goals tailored toward experimental versatility is highlighted. The instrument is unique in its detector and x-ray source configuration, both of which enable elevated optimization of spatial and temporal resolution. The process for component selection is provided. The selected components are specified, the custom component design discussed, and the integration of both into a fully functional XCT instrument is outlined. The novelty of this design is a new lab-scale detector and imaging optimization through x-ray source and detector modularity.

  1. X-ray micro-tomography investigation of the foaming process in the system of waste glass–silica mud–MnO{sub 2}

    SciTech Connect (OSTI)

    Ducman, V., E-mail: vilma.ducman@zag.si [ZAG Ljubljana, Dimi?eva 12, 1000 Ljubljana (Slovenia); Korat, L.; Legat, A. [ZAG Ljubljana, Dimi?eva 12, 1000 Ljubljana (Slovenia); Mirti?, B. [NTF, Ašker?eva 12, 1000 Ljubljana (Slovenia)

    2013-12-15T23:59:59.000Z

    In case of foamed lightweight aggregates (LWAs), porosity is introduced by the addition of a foaming agent to the glassy matrix, which degasses at an elevated temperature, so that the resulting gases remain trapped inside the glassy structure. The efficiency of action of MnO{sub 2} as a foaming agent in waste glass and waste glass/silica mud systems was studied. Samples were fired at different temperatures and with different dwelling times at a certain temperature, and the development of porosity was investigated by means of X-ray micro-tomography. It was found that, with the prolongation in dwelling times, the number of pores decreased, while, on the other hand, the volume of these pores increased, and that the addition of silica mud increases the foaming temperature and slows down the foaming process. - Highlights: • Preparation of lightweight aggregate from waste glass, silica sludge, and MnO{sub 2} • DTA/TG investigation of MnO{sub 2} • Characterization of pore-forming process by means of X-ray micro-tomography (?cT)

  2. SNR-weighted Sinogram Smoothing with Improved Noise-resolution Properties for Low-dose X-ray Computed Tomography

    E-Print Network [OSTI]

    -ray Computed Tomography T. Li*a , J. Wanga , J. Wena , X. Lib , H. Luc , J. Hsiehd , and Z. Lianga a State-beam, uniform attenuation, resolution variation. 1. INTRODUCTION It is well known that the quality of computed tomography (CT) images would be severely degraded by the excessive quantum noise under extremely low x

  3. Lensless Imaging of Whole Biological Cells with Soft X-Rays

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cells with Soft X-Rays Lensless Imaging of Whole Biological Cells with Soft X-Rays Print Wednesday, 26 May 2010 00:00 A team of scientists has used x-ray diffraction...

  4. E-Print Network 3.0 - acute low-level x-rays Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Group Publications Collection: Physics 68 Search for X-ray Afterglows from Gamma-Ray Bursts in the RASS Summary: with low-level (below the RASS thresh- old) persistent...

  5. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging in Reflection Print Wednesday, 26 October 2011 00:00 The advent of x-ray free-electron laser (XFEL) light sources has led to an outburst of research activities in the field...

  6. A 4D Synchrotron X-Ray-Tomography Study of the Formation of Hydrocarbon- Migration Pathways in Heated Organic-Rich Shale

    SciTech Connect (OSTI)

    Hamed Panahi; Paul Meakin; Francois Renard; Maya Kobchenko; Julien Scheibert; Adriano Mazzini; Bjorn Jamtveit; Anders Malthe-Sorenssen; Dag Kristian Dysthe

    2013-04-01T23:59:59.000Z

    Recovery of oil from oil shales and the natural primary migration of hydrocarbons are closely related processes that have received renewed interest in recent years because of the ever tightening supply of conventional hydrocarbons and the growing production of hydrocarbons from low-permeability tight rocks. Quantitative models for conversion of kerogen into oil and gas and the timing of hydrocarbon generation have been well documented. However, lack of consensus about the kinetics of hydrocarbon formation in source rocks, expulsion timing, and how the resulting hydrocarbons escape from or are retained in the source rocks motivates further investigation. In particular, many mechanisms have been proposed for the transport of hydrocarbons from the rocks in which they are generated into adjacent rocks with higher permeabilities and smaller capillary entry pressures, and a better understanding of this complex process (primary migration) is needed. To characterize these processes, it is imperative to use the latest technological advances. In this study, it is shown how insights into hydrocarbon migration in source rocks can be obtained by using sequential high-resolution synchrotron X-ray tomography. Three-dimensional images of several immature "shale" samples were constructed at resolutions close to 5 um. This is sufficient to resolve the source-rock structure down to the grain level, but very-fine-grained silt particles, clay particles, and colloids cannot be resolved. Samples used in this investigation came from the R-8 unit in the upper part of the Green River shale, which is organic rich, varved, lacustrine marl formed in Eocene Lake Uinta, USA. One Green River shale sample was heated in situ up to 400 degrees C as X-ray-tomography images were recorded. The other samples were scanned before and after heating at 400 degrees C. During the heating phase, the organic matter was decomposed, and gas was released. Gas expulsion from the low-permeability shales was coupled with formation of microcracks. The main technical difficulty was numerical extraction of microcracks that have apertures in the 5- to 30-um range (with 5 um being the resolution limit) from a large 3D volume of X-ray attenuation data. The main goal of the work presented here is to develop a methodology to process these 3D data and image the cracks. This methodology is based on several levels of spatial filtering and automatic recognition of connected domains. Supportive petrographic and thermogravimetric data were an important complement to this study. An investigation of the strain field using 2D image correlation analyses was also performed. As one application of the 4D (space + time) microtomography and the developed workflow, we show that fluid generation was accompanied by crack formation. Under different conditions, in the subsurface, this might provide paths for primary migration.

  7. Application of x-ray tomography to optimization of new NOx/NH3 mixed potential sensors for vehicle on-board emissions control

    SciTech Connect (OSTI)

    Nelson, Mark A [Los Alamos National Laboratory; Brosha, Eric L [Los Alamos National Laboratory; Mukundan, Rangachary [Los Alamos National Laboratory; Garzon, Fernando H [Los Alamos National Laboratory

    2009-01-01T23:59:59.000Z

    Mixed potential sensors for the detection of hydrocarbons, NO{sub x}, and NH{sub 3} have been previously developed at Los Alamos National Laboratory (LANL). The LANL sensors have a unique design incorporating dense ceramic-pelletlmetal-wire electrodes and porous electrolytes. The performance of current-biased sensors using an yttria-stabilized zirconia (YSZ) electrolyte and platinum and La{sub 0.8}Sr{sub 0.2}CrO{sub 3} electrodes is reported. X-ray tomography has been applied to non-destructively examine internal structures of these sensors. NO{sub x} and hydrocarbon response of the sensors under various bias conditions is reported, and very little NO{sub x} response hysteresis was observed. The application of a 0.6 {mu}A bias to these sensors shifts the response from a hydrocarbon response to a NO{sub x} response equal for both NO and NO{sub 2} species at approximately 500 {sup o}C in air.

  8. A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

    SciTech Connect (OSTI)

    Ruehrnschopf, Ernst-Peter; Klingenbeck, Klaus [Siemens AG, Healthcare Sector, Imaging and Therapy Division, Forchheim (Germany)

    2011-07-15T23:59:59.000Z

    Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

  9. Effect of Network Structure on Characterization and Flow Modeling Using X-ray Micro-Tomography Images of Granular and Fibrous Porous Media

    SciTech Connect (OSTI)

    Bhattad, Pradeep; Willson, Clinton S.; Thompson, Karsten E. (LSU)

    2012-07-31T23:59:59.000Z

    Image-based network modeling has become a powerful tool for modeling transport in real materials that have been imaged using X-ray computed micro-tomography (XCT) or other three-dimensional imaging techniques. Network generation is an essential part of image-based network modeling, but little quantitative work has been done to understand the influence of different network structures on modeling. We use XCT images of three different porous materials (disordered packings of spheres, sand, and cylinders) to create a series of four networks for each material. Despite originating from the same data, the networks can be made to vary over two orders of magnitude in pore density, which in turn affects network properties such as pore-size distribution and pore connectivity. Despite the orders-of-magnitude difference in pore density, single-phase permeability predictions remain remarkably consistent for a given material, even for the simplest throat conductance formulas. Detailed explanations for this beneficial attribute are given in the article; in general, it is a consequence of using physically representative network models. The capillary pressure curve generated from quasi-static drainage is more sensitive to network structure than permeability. However, using the capillary pressure curve to extract pore-size distributions gives reasonably consistent results even though the networks vary significantly. These results provide encouraging evidence that robust network modeling algorithms are not overly sensitive to the specific structure of the underlying physically representative network, which is important given the variety image-based network-generation strategies that have been developed in recent years.

  10. Modeling pure methane hydrate dissociation using a numerical simulator from a novel combination of X-ray computed tomography and macroscopic data

    SciTech Connect (OSTI)

    Gupta, A.; Moridis, G.J.; Kneafsey, T.J.; Sloan, Jr., E.D.

    2009-08-15T23:59:59.000Z

    The numerical simulator TOUGH+HYDRATE (T+H) was used to predict the transient pure methane hydrate (no sediment) dissociation data. X-ray computed tomography (CT) was used to visualize the methane hydrate formation and dissociation processes. A methane hydrate sample was formed from granular ice in a cylindrical vessel, and slow depressurization combined with thermal stimulation was applied to dissociate the hydrate sample. CT images showed that the water produced from the hydrate dissociation accumulated at the bottom of the vessel and increased the hydrate dissociation rate there. CT images were obtained during hydrate dissociation to confirm the radial dissociation of the hydrate sample. This radial dissociation process has implications for dissociation of hydrates in pipelines, suggesting lower dissociation times than for longitudinal dissociation. These observations were also confirmed by the numerical simulator predictions, which were in good agreement with the measured thermal data during hydrate dissociation. System pressure and sample temperature measured at the sample center followed the CH{sub 4} hydrate L{sub w}+H+V equilibrium line during hydrate dissociation. The predicted cumulative methane gas production was within 5% of the measured data. Thus, this study validated our simulation approach and assumptions, which include stationary pure methane hydrate-skeleton, equilibrium hydrate-dissociation and heat- and mass-transfer in predicting hydrate dissociation in the absence of sediments. It should be noted that the application of T+H for the pure methane hydrate system (no sediment) is outside the general applicability limits of T+H.

  11. Proceedings of the workshop on X-ray computed microtomography

    SciTech Connect (OSTI)

    NONE

    1998-02-01T23:59:59.000Z

    This report consists of vugraphs from the nine presentations at the conference. Titles of the presentations are: CMT: Applications and Techniques; Computer Microtomography Using X-rays from Third Generation Synchrotron X-ray; Approaches to Soft-X-ray Nanotomography; Diffraction Enhanced Tomography; X-ray Computed Microtomography Applications at the NSLS; XCMT Applications in Forestry and Forest Products; 3DMA: Investigating Three Dimensional Pore Geometry from High Resolution Images; X-ray Computed Microtomography Studies of Volcanic Rock; and 3-D Visualization of Tomographic Volumes.

  12. Lensless Imaging of Whole Biological Cells with Soft X-Rays

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lensless Imaging of Whole Biological Cells with Soft X-Rays Print A team of scientists has used x-ray diffraction microscopy at ALS Beamline 9.0.1 to make images of whole yeast...

  13. Chest x-Rays

    Broader source: Energy.gov [DOE]

    The B-reading is a special reading of a standard chest x-ray film performed by a physician certified by the National Institute for Occupational Safety and Health (NIOSH). The reading looks for changes on the chest x-ray that may indicate exposure and disease caused by agents such as asbestos or silica.

  14. Catalog of supersoft X-ray sources

    E-Print Network [OSTI]

    J. Greiner

    2000-05-11T23:59:59.000Z

    This catalog comprises an up-to-date (December 1999) list of luminous (>10^36 erg/s), binary supersoft X-ray sources. This electronic version (including the accompannying Web-pages) supersedes the printed version of Greiner (1996).

  15. Using Light to Control How X Rays Interact with Matter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Using Light to Control How X Rays Interact with Matter Print Schemes that use one light pulse to manipulate interactions of another with matter are well developed in the...

  16. X-ray laser

    DOE Patents [OSTI]

    Nilsen, Joseph (Livermore, CA)

    1991-01-01T23:59:59.000Z

    An X-ray laser (10) that lases between the K edges of carbon and oxygen, i.e. between 44 and 23 Angstroms, is provided. The laser comprises a silicon (12) and dysprosium (14) foil combination (16) that is driven by two beams (18, 20) of intense line focused (22, 24) optical laser radiation. Ground state nickel-like dysprosium ions (34) are resonantly photo-pumped to their upper X-ray laser state by line emission from hydrogen-like silicon ions (32). The novel X-ray laser should prove especially useful for the microscopy of biological specimens.

  17. X-ray beam finder

    DOE Patents [OSTI]

    Gilbert, H.W.

    1983-06-16T23:59:59.000Z

    An X-ray beam finder for locating a focal spot of an X-ray tube includes a mass of X-ray opaque material having first and second axially-aligned, parallel-opposed faces connected by a plurality of substantially identical parallel holes perpendicular to the faces and a film holder for holding X-ray sensitive film tightly against one face while the other face is placed in contact with the window of an X-ray head.

  18. X-ray lithography using holographic images

    DOE Patents [OSTI]

    Howells, Malcolm S. (Berkeley, CA); Jacobsen, Chris (Sound Beach, NY)

    1997-01-01T23:59:59.000Z

    Methods for forming X-ray images having 0.25 .mu.m minimum line widths on X-ray sensitive material are presented. A holgraphic image of a desired circuit pattern is projected onto a wafer or other image-receiving substrate to allow recording of the desired image in photoresist material. In one embodiment, the method uses on-axis transmission and provides a high flux X-ray source having modest monochromaticity and coherence requirements. A layer of light-sensitive photoresist material on a wafer with a selected surface is provided to receive the image(s). The hologram has variable optical thickness and variable associated optical phase angle and amplitude attenuation for transmission of the X-rays. A second embodiment uses off-axis holography. The wafer receives the holographic image by grazing incidence reflection from a hologram printed on a flat metal or other highly reflecting surface or substrate. In this second embodiment, an X-ray beam with a high degree of monochromaticity and spatial coherence is required.

  19. X-ray lithography using holographic images

    DOE Patents [OSTI]

    Howells, M.S.; Jacobsen, C.

    1997-03-18T23:59:59.000Z

    Methods for forming X-ray images having 0.25 {micro}m minimum line widths on X-ray sensitive material are presented. A holographic image of a desired circuit pattern is projected onto a wafer or other image-receiving substrate to allow recording of the desired image in photoresist material. In one embodiment, the method uses on-axis transmission and provides a high flux X-ray source having modest monochromaticity and coherence requirements. A layer of light-sensitive photoresist material on a wafer with a selected surface is provided to receive the image(s). The hologram has variable optical thickness and variable associated optical phase angle and amplitude attenuation for transmission of the X-rays. A second embodiment uses off-axis holography. The wafer receives the holographic image by grazing incidence reflection from a hologram printed on a flat metal or other highly reflecting surface or substrate. In this second embodiment, an X-ray beam with a high degree of monochromaticity and spatial coherence is required. 15 figs.

  20. X-Ray Diagnostics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del SolStrengtheningWildfires may contribute more toConsensusX-Ray Diagnostics X-Ray

  1. Fluctuation X-Ray Scattering

    SciTech Connect (OSTI)

    Saldin, PI: D. K.; Co-I's: J. C. H. Spence and P. Fromme

    2013-01-25T23:59:59.000Z

    The work supported by the grant was aimed at developing novel methods of finding the structures of biomolecules using x-rays from novel sources such as the x-ray free electron laser and modern synchrotrons

  2. Tunable X-ray source

    DOE Patents [OSTI]

    Boyce, James R. (Williamsburg, VA)

    2011-02-08T23:59:59.000Z

    A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

  3. X-ray lithography source

    DOE Patents [OSTI]

    Piestrup, Melvin A. (Woodside, CA); Boyers, David G. (Mountain View, CA); Pincus, Cary (Sunnyvale, CA)

    1991-01-01T23:59:59.000Z

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and elminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an exellent moderate-priced X-ray source for lithography.

  4. X-ray lithography source

    DOE Patents [OSTI]

    Piestrup, M.A.; Boyers, D.G.; Pincus, C.

    1991-12-31T23:59:59.000Z

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits is disclosed. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and eliminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an excellent moderate-priced X-ray source for lithography. 26 figures.

  5. X-ray spectrometry

    SciTech Connect (OSTI)

    Markowicz, A.A.; Van Grieken, R.E.

    1986-04-01T23:59:59.000Z

    In the period under review, i.e, through 1984 and 1985, some 600 articles on XRS (X-ray spectrometry) were published; most of these have been scanned and the most fundamental ones are discussed. All references will refer to English-language articles, unless states otherwise. Also general books have appeared on quantitative EPXMA (electron-probe X-ray microanalysis) and analytical electron microscopy (AEM) as well as an extensive review on the application of XRS to trace analysis of environmental samples. In the period under review no radically new developments have been seen in XRS. However, significant improvements have been made. Gain in intensities has been achieved by more efficient excitation, higher reflectivity of dispersing media, and better geometry. Better understanding of the physical process of photon- and electron-specimen interactions led to complex but more accurate equations for correction of various interelement effects. Extensive use of micro- and minicomputers now enables fully automatic operation, including qualitative analysis. However, sample preparation and presentation still put a limit to further progress. Although some authors find XRS in the phase of stabilization or even stagnation, further gradual developments are expected, particularly toward more dedicated equipment, advanced automation, and image analysis systems. Ways are outlined in which XRS has been improved in the 2 last years by excitation, detection, instrumental, methodological, and theoretical advances. 340 references.

  6. Characterizing Low-Permeable Granitic Rock From Micrometer to Centimeter Scale: X-ray Micro-computed Tomography, Confocal Laser Scanning Microscopy and {sup 14}C-PMMA Method

    SciTech Connect (OSTI)

    Laehdemaeki, T.; Kelokaski, M.; Siitari-Kauppi, M. [Laboratory of Radiochemistry, University of Helsinki, P.O.Box 55, University of Helsinki, FIN- 00014 (Finland); Voutilainen, M.; Myllys, M.; Turpeinen, T.; Timonen, J. [Department of Physics, University of Jyvaeskylae, P.O.Box 35, Jyvaeskylae, FIN-40351 (Finland); Mateos, F.; Montoto, M. [Department of Geology, University of Oviedo, Oviedo, 33005 (Spain)

    2007-07-01T23:59:59.000Z

    First results of combining X-ray micro-computed tomography ({mu}CT), confocal laser-scanning microscopy (CLSM) and {sup 14}C-poly-methyl-methacrylate ({sup 14}C-PMMA) impregnation techniques in the study of granitic rock samples are reported. Combining results of {mu}CT and CLSM with those of the {sup 14}C-PMMA technique, the mineral-specific porosity and morphology of the open pore space, as well as its connectivity, could be analyzed from a micrometer up to a decimeter scale. Three different types of granite were studied. In two cases part of the micro-fissure and pore apertures were found to be in a micrometer scale, but in one case all grain-boundary openings were below the detection limit. Micrometer-scale apertures could be analyzed by CLSM and {mu}CT. The benefit of {mu}CT is that it can also provide the heterogeneous distribution of minerals in 3D. The 2D porosity distributions in the mineral phases, consisting of nanometer-scale pores, could be measured by the {sup 14}C-PMMA method together with the micro-fissures. This method does not, however, give the exact pore apertures. The limitations and applicability of the methods are discussed. (authors)

  7. Miniature x-ray source

    DOE Patents [OSTI]

    Trebes, James E. (Livermore, CA); Stone, Gary F. (Livermore, CA); Bell, Perry M. (Tracy, CA); Robinson, Ronald B. (Modesto, CA); Chornenky, Victor I. (Minnetonka, MN)

    2002-01-01T23:59:59.000Z

    A miniature x-ray source capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature x-ray source comprises a compact vacuum tube assembly containing a cathode, an anode, a high voltage feedthru for delivering high voltage to the anode, a getter for maintaining high vacuum, a connection for an initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is highly x-ray transparent and made, for example, from boron nitride. The compact size and potential for remote operation allows the x-ray source, for example, to be placed adjacent to a material sample undergoing analysis or in proximity to the region to be treated for medical applications.

  8. advanced computed tomography: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2007-01-01 4 Geometric Tomography: A Limited-View Approach for Computed Tomography Computer Technologies and Information Sciences Websites Summary: Geometric Tomography: A...

  9. Thermal Neutron Computed Tomography of Soil Water and Plant Roots

    E-Print Network [OSTI]

    Leanne G. Tumlinson; Hungyuan Liu; Wendy K. Silk; Jan W. Hopmans

    2007-01-01T23:59:59.000Z

    2000. 3D neutron computed tomography: Requirements and2002. Using x-ray computed tomography in hydrology: Systems,of neutron computed tomography in the geosciences. Nucl.

  10. X-Ray Imaging of the Dynamic Magnetic Vortex Core Deformation

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-Ray Imaging of the Dynamic Magnetic Vortex Core Deformation Print Magnetic thin-film nanostructures can exhibit a magnetic vortex state in which the magnetization vectors lie in...

  11. Center for X-Ray Optics, 1992

    SciTech Connect (OSTI)

    Not Available

    1993-08-01T23:59:59.000Z

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors.

  12. X-ray Computed Tomography | EMSL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    battery materials, catalyst beds, and microreactors. Collaborative work with EMSL's Graphics and Visualization Laboratory enhances three-dimensional visualization of XCT data....

  13. Miniature x-ray source

    DOE Patents [OSTI]

    Trebes, James E. (Livermore, CA); Bell, Perry M. (Tracy, CA); Robinson, Ronald B. (Modesto, CA)

    2000-01-01T23:59:59.000Z

    A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

  14. Reduction of radiation dose to radiosensitive organs and its tradeoff with image quality in Computed Tomography

    E-Print Network [OSTI]

    Zhang, Di

    2012-01-01T23:59:59.000Z

    helical multislice computed tomography examination. MedicalRadiation Dose in X-Ray Computed Tomography. AAPM report NO.of X-ray equipment for computed tomography. (2002). American

  15. Interferometric phase detection at x-ray energies via Fano resonance control

    E-Print Network [OSTI]

    K. P. Heeg; C. Ott; D. Schumacher; H. -C. Wille; R. Röhlsberger; T. Pfeifer; J. Evers

    2014-11-06T23:59:59.000Z

    Modern x-ray light sources promise access to structure and dynamics of matter in largely unexplored spectral regions. However, the desired information is encoded in the light intensity and phase, whereas detectors register only the intensity. This phase problem is ubiquitous in crystallography and imaging, and impedes the exploration of quantum effects at x-ray energies. Here, we demonstrate phase-sensitive measurements characterizing the quantum state of a nuclear two-level system at hard x-ray energies. The nuclei are initially prepared in a superposition state. Subsequently, the relative phase of this superposition is interferometrically reconstructed from the emitted x-rays. Our results form a first step towards x-ray quantum state tomography, and provide new avenues for structure determination and precision metrology via x-ray Fano interference.

  16. Compact x-ray source and panel

    DOE Patents [OSTI]

    Sampayon, Stephen E. (Manteca, CA)

    2008-02-12T23:59:59.000Z

    A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

  17. Characterization of Biological Effects of Computed Tomography by Assessing the DNA Damage Response

    E-Print Network [OSTI]

    Elgart, Shona Robin

    2014-01-01T23:59:59.000Z

    Brenner DJ, Hall EJ. Computed Tomography - An IncreasingSmith-Bindman R. Is Computed Tomography Safe? New Englandof X-ray Trends: Computed Tomography 2005 – 06 Preliminary

  18. Focused X-ray source

    DOE Patents [OSTI]

    Piestrup, M.A.; Boyers, D.G.; Pincus, C.I.; Maccagno, P.

    1990-08-21T23:59:59.000Z

    Disclosed is an intense, relatively inexpensive X-ray source (as compared to a synchrotron emitter) for technological, scientific, and spectroscopic purposes. A conical radiation pattern produced by a single foil or stack of foils is focused by optics to increase the intensity of the radiation at a distance from the conical radiator. 8 figs.

  19. Producing X-rays at the APS

    ScienceCinema (OSTI)

    None

    2013-04-19T23:59:59.000Z

    An introduction and overview of the Advanced Photon Source at Argonne National Laboratory, the technology that produces the brightest X-ray beams in the Western Hemisphere, and the research carried out by scientists using those X-rays.

  20. APS X-rays Reveal Picasso's Secret

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    | 2003 | 2002 | 2001 2000 Subscribe to APS News rss feed APS X-rays Reveal Picasso's Secret OCTOBER 15, 2012 Bookmark and Share X-rays reveal that Picasso's "Old Guitarist," at...

  1. Spectral analysis of X-ray binaries

    E-Print Network [OSTI]

    Fridriksson, Joel Karl

    2011-01-01T23:59:59.000Z

    In this thesis, I present work from three separate research projects associated with observations of X-ray binaries. Two of those revolve around spectral characteristics of neutron star low-mass X-ray binaries (NS-LMXBs), ...

  2. Microgap x-ray detector

    DOE Patents [OSTI]

    Wuest, C.R.; Bionta, R.M.; Ables, E.

    1994-05-03T23:59:59.000Z

    An x-ray detector is disclosed which provides for the conversion of x-ray photons into photoelectrons and subsequent amplification of these photoelectrons through the generation of electron avalanches in a thin gas-filled region subject to a high electric potential. The detector comprises a cathode (photocathode) and an anode separated by the thin, gas-filled region. The cathode may comprise a substrate, such a beryllium, coated with a layer of high atomic number material, such as gold, while the anode can be a single conducting plane of material, such as gold, or a plane of resistive material, such as chromium/silicon monoxide, or multiple areas of conductive or resistive material, mounted on a substrate composed of glass, plastic or ceramic. The charge collected from each electron avalanche by the anode is passed through processing electronics to a point of use, such as an oscilloscope. 3 figures.

  3. Microgap x-ray detector

    DOE Patents [OSTI]

    Wuest, Craig R. (Danville, CA); Bionta, Richard M. (Livermore, CA); Ables, Elden (Livermore, CA)

    1994-01-01T23:59:59.000Z

    An x-ray detector which provides for the conversion of x-ray photons into photoelectrons and subsequent amplification of these photoelectrons through the generation of electron avalanches in a thin gas-filled region subject to a high electric potential. The detector comprises a cathode (photocathode) and an anode separated by the thin, gas-filled region. The cathode may comprise a substrate, such a beryllium, coated with a layer of high atomic number material, such as gold, while the anode can be a single conducting plane of material, such as gold, or a plane of resistive material, such as chromium/silicon monoxide, or multiple areas of conductive or resistive material, mounted on a substrate composed of glass, plastic or ceramic. The charge collected from each electron avalanche by the anode is passed through processing electronics to a point of use, such as an oscilloscope.

  4. Phase-sensitive X-ray imager

    DOE Patents [OSTI]

    Baker, Kevin Louis

    2013-01-08T23:59:59.000Z

    X-ray phase sensitive wave-front sensor techniques are detailed that are capable of measuring the entire two-dimensional x-ray electric field, both the amplitude and phase, with a single measurement. These Hartmann sensing and 2-D Shear interferometry wave-front sensors do not require a temporally coherent source and are therefore compatible with x-ray tubes and also with laser-produced or x-pinch x-ray sources.

  5. The Relationship between Organ Dose and Patients Size in Multidetector Computed Tomography (MDCT) Scans Utilizing Tube Current Modulation (TCM)

    E-Print Network [OSTI]

    Khatonabadi, Maryam

    2013-01-01T23:59:59.000Z

    D. and E. Hall, Computed tomography - An increasing source7430): p. 19. FDA, Computed Tomography (CT). Food and Drugtransmission x-ray computed tomography. Med Phys, 1981. 8(

  6. X-ray spectroscopy of low-mass X-ray binaries

    E-Print Network [OSTI]

    Juett, Adrienne Marie, 1976-

    2004-01-01T23:59:59.000Z

    I present high-resolution X-ray grating spectroscopy of neutron stars in low-mass X-ray binaries (LMXBs) using instruments onboard the Chandra X-ray Observatory and the X-ray Multi-Mirror Mission (XMM-Newton). The first ...

  7. Extending The Methodology Of X-ray Crystallography To Allow X-ray

    E-Print Network [OSTI]

    Miao, Jianwei "John"

    , the radiation damage. While the radiation damage problem can be mitigated somewhat by using cryogenic techniques resolution without serious radiation damage to the specimens. Although X-ray crystallography becomesExtending The Methodology Of X-ray Crystallography To Allow X-ray Microscopy Without X-ray Optics

  8. Postmortem analysis of sand grain crushing from pile interface using X-ray I. Matas Silva, Gal Combe, Pierre Foray, Frdric Flin, and Bernard Lesaffre

    E-Print Network [OSTI]

    Ribes, Aurélien

    Postmortem analysis of sand grain crushing from pile interface using X-ray tomography I. Matías of Sand Grain Crushing From Pile Interface Using X-ray Tomography Matías Silva I., Gaël Combe, Pierre. Pile foundations of offshore platforms, wind and water turbines are typically subjected to a variety

  9. Synchronization of x-ray pulses to the pump laser in an ultrafast x-ray facility

    E-Print Network [OSTI]

    Corlett, J.N.; Barry, W.; Byrd, J.M.; Schoenlein, R.; Zholents, A.

    2002-01-01T23:59:59.000Z

    Accurate timing of ultrafast x-ray probe pulses emitted fromOF X-RAY PULSES TO THE PUMP LASER IN AN ULTRAFAST X-RAY

  10. assisted tomography romicat: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the...

  11. abdominal computerized tomography: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the...

  12. X-ray holography of biological specimens

    SciTech Connect (OSTI)

    Solem, J.C.

    1984-01-01T23:59:59.000Z

    The author reviews the reasons for x-ray imaging of biological specimens and the techniques presently being used for x-ray microscopy. The author points out the advantages of x-ray holography and the difficulties of obtaining the requisite coherence with conventional sources. The author discusses the problems of radiation damage and the remarkable fact that short pulse x-ray sources circumvent these problems and obtain high-resolution images of specimens in the living state. Finally, the author reviews some of the efforts underway to develop high-intensity coherent x-ray sources for the laboratory. 14 references, 5 figures, 2 tables.

  13. Soft X-ray techniques to study mesoscale magnetism

    E-Print Network [OSTI]

    Kortright, Jeffrey B.

    2003-01-01T23:59:59.000Z

    X-Ray Techniques to Study Mesoscale Magnetism Jeffrey B.X-Ray Techniques to Study Mesoscale Magnetism Jeffrey B.

  14. Techniques for synchronization of X-Ray pulses to the pump laser in an ultrafast X-Ray facility

    E-Print Network [OSTI]

    Corlett, J.N.; Doolittle, L.; Schoenlein, R.; Staples, J.; Wilcox, R.; Zholents, A.

    2003-01-01T23:59:59.000Z

    synchronization of ultrafast x-ray pulses produced in theAccurate timing of ultrafast x-ray probe pulses emitted fromOF X-RAY PULSES TO THE PUMP LASER IN AN ULTRAFAST X-RAY

  15. Controlling X-rays With Light

    SciTech Connect (OSTI)

    Glover, Ernie; Hertlein, Marcus; Southworth, Steve; Allison, Tom; van Tilborg, Jeroen; Kanter, Elliot; Krassig, B.; Varma, H.; Rude, Bruce; Santra, Robin; Belkacem, Ali; Young, Linda

    2010-08-02T23:59:59.000Z

    Ultrafast x-ray science is an exciting frontier that promises the visualization of electronic, atomic and molecular dynamics on atomic time and length scales. A largelyunexplored area of ultrafast x-ray science is the use of light to control how x-rays interact with matter. In order to extend control concepts established for long wavelengthprobes to the x-ray regime, the optical control field must drive a coherent electronic response on a timescale comparable to femtosecond core-hole lifetimes. An intense field is required to achieve this rapid response. Here an intense optical control pulse isobserved to efficiently modulate photoelectric absorption for x-rays and to create an ultrafast transparency window. We demonstrate an application of x-ray transparencyrelevant to ultrafast x-ray sources: an all-photonic temporal cross-correlation measurement of a femtosecond x-ray pulse. The ability to control x-ray/matterinteractions with light will create new opportunities at current and next-generation x-ray light sources.

  16. X-ray Observations of Mrk 231

    E-Print Network [OSTI]

    T. J. Turner

    1998-08-10T23:59:59.000Z

    This paper presents new X-ray observations of Mrk 231, an active galaxy of particular interest due to its large infrared luminosity and the presence of several blueshifted broad absorption line (BAL) systems, a phenomenon observed in a small fraction of QSOs. A ROSAT HRI image of Mrk 231 is presented, this shows an extended region of soft X-ray emission, covering several tens of kpc, consistent with the extent of the host galaxy. An ASCA observation of Mrk 231 is also presented. Hard X-rays are detected but the data show no significant variability in X-ray flux. The hard X-ray continuum is heavily attenuated and X-ray column estimates range from ~ 2 x 10^{22} - 10^{23} cm^{-2} depending on whether the material is assumed to be neutral or ionized, and on the model assumed for the extended X-ray component. These ASCA data provide only the second hard X-ray spectrum of a BAL AGN presented to date. The broad-band spectral-energy-distribution of the source is discussed. While Mrk 231 is X-ray weak compared to Seyfert 1 galaxies, it has an optical-to-X-ray spectrum typical of a QSO.

  17. aids computed tomography: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Computer-aided diagnosis of rheumatoid arthritis with optical tomography, Part Computer...

  18. X-ray transmissive debris shield

    DOE Patents [OSTI]

    Spielman, Rick B. (Albuquerque, NM)

    1994-01-01T23:59:59.000Z

    A composite window structure is described for transmitting x-ray radiation and for shielding radiation generated debris. In particular, separate layers of different x-ray transmissive materials are laminated together to form a high strength, x-ray transmissive debris shield which is particularly suited for use in high energy fluences. In one embodiment, the composite window comprises alternating layers of beryllium and a thermoset polymer.

  19. High speed x-ray beam chopper

    DOE Patents [OSTI]

    McPherson, Armon (Oswego, IL); Mills, Dennis M. (Naperville, IL)

    2002-01-01T23:59:59.000Z

    A fast, economical, and compact x-ray beam chopper with a small mass and a small moment of inertia whose rotation can be synchronized and phase locked to an electronic signal from an x-ray source and be monitored by a light beam is disclosed. X-ray bursts shorter than 2.5 microseconds have been produced with a jitter time of less than 3 ns.

  20. X-ray populations in galaxies

    E-Print Network [OSTI]

    G. Fabbiano

    2005-11-09T23:59:59.000Z

    Today's sensistive, high resolution Chandra X-ray observations allow the study of many populations of X-ray sources. The traditional astronomical tools of photometric diagrams and luminosity functions are now applied to these populations, and provide the means for classifying the X-ray sources and probing their evolution. While overall stellar mass drives the amount of X-ray binaries in old stellar population, the amount of sources in star-forming galaxies is related to the star formation rate. Shart-lived, luminous, high mass binaries (HNXBs) dominate these young populations.

  1. X-ray laser microscope apparatus

    DOE Patents [OSTI]

    Suckewer, Szymon (Princeton, NJ); DiCicco, Darrell S. (Plainsboro, NJ); Hirschberg, Joseph G. (Coral Gables, FL); Meixler, Lewis D. (East Windsor, NJ); Sathre, Robert (Princeton, NJ); Skinner, Charles H. (Lawrenceville, NJ)

    1990-01-01T23:59:59.000Z

    A microscope consisting of an x-ray contact microscope and an optical microscope. The optical, phase contrast, microscope is used to align a target with respect to a source of soft x-rays. The source of soft x-rays preferably comprises an x-ray laser but could comprise a synchrotron or other pulse source of x-rays. Transparent resist material is used to support the target. The optical microscope is located on the opposite side of the transparent resist material from the target and is employed to align the target with respect to the anticipated soft x-ray laser beam. After alignment with the use of the optical microscope, the target is exposed to the soft x-ray laser beam. The x-ray sensitive transparent resist material whose chemical bonds are altered by the x-ray beam passing through the target mater GOVERNMENT LICENSE RIGHTS This invention was made with government support under Contract No. De-FG02-86ER13609 awarded by the Department of Energy. The Government has certain rights in this invention.

  2. X-ray spectroscopy of neutron star low-mass X-ray binaries

    E-Print Network [OSTI]

    Krauss, Miriam Ilana

    2007-01-01T23:59:59.000Z

    In this thesis, I present work spanning a variety of topics relating to neutron star lowmass X-ray binaries (LMXBs) and utilize spectral information from X-ray observations to further our understanding of these sources. ...

  3. Metal Artifact Reduction in Computed Tomography /

    E-Print Network [OSTI]

    Karimi, Seemeen

    2014-01-01T23:59:59.000Z

    Monoenergetic imaging of dual-energy CT reduces artifactsartifact reduction by dual energy computed tomography usingimage re- construction for dual energy X-ray transmission

  4. absorption spectroscopic tomography: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    absorption spectroscopic tomography First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Separation of...

  5. Phased Contrast X-Ray Imaging

    ScienceCinema (OSTI)

    Erin Miller

    2012-12-31T23:59:59.000Z

    The Pacific Northwest National Laboratory is developing a range of technologies to broaden the field of explosives detection. Phased contrast X-ray imaging, which uses silicon gratings to detect distortions in the X-ray wave front, may be applicable to mail or luggage scanning for explosives; it can also be used in detecting other contraband, small-parts inspection, or materials characterization.

  6. X-ray source populations in galaxies

    E-Print Network [OSTI]

    G. Fabbiano

    2005-11-16T23:59:59.000Z

    Today's sensitive, high-resolution X-ray observations allow the study of populations of X-ray sources, in the luminosity range of Galactic X-ray binaries, in galaxies as distant as 20-30 Mpc. The traditional astronomical tools of photometric diagrams and luminosity functions are now applied to these populations, providing a direct probe of the evolved binary component of different stellar populations. The study of the X-ray populations of E and S0 galaxies has revamped the debate on the formation and evolution of low-mass X-ray binaries (LMXBs) and on the role of globular clusters in these processes. While overall stellar mass drives the amount of X-ray binaries in old stellar populations, the amount of sources in star forming galaxies is related to the star formation rate. Short-lived, luminous, high-mass binaries (HMXBs) dominate these young populations. The most luminous sources in these systems are the debated ULXs, which have been suggested to be ~100-1000 Msol black holes, but could alternatively include a number of binaries with stellar mass black holes. Very soft sources have also been discovered in many galaxies and their nature is currently being debated. Observations of the deep X-ray sky, and comparison with deep optical surveys, are providing the first evidence of the X-ray evolution of galaxies.

  7. X-Ray Nanoimaging: Instruments and Methods

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del SolStrengtheningWildfires may contribute more toConsensusX-RayX-Ray ImagingX-Ray

  8. aided ct image: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging X-rays Computed Tomography (CT) Positron Emission Tomography (PET 12;LSO-APD Array Schematic 12;Time-of-Flight PET 12;Energy Spectrum with lutetium...

  9. Hard X-ray Fluorescence Measurements of Heteroepitaxial Solid...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Hard X-ray Fluorescence Measurements of Heteroepitaxial Solid Oxide Fuel Cell Cathode Materials. Hard X-ray Fluorescence Measurements of Heteroepitaxial Solid Oxide Fuel Cell...

  10. Manipulating X-rays with Tiny Mirrors | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    for controlling X-rays. MEMS, or microelectromechanical systems, allow shrinking the optics to the microscale creating ultrafast devices for reflecting X-rays at precise times...

  11. Fuel Injection and Spray Research Using X-Ray Diagnostics

    Broader source: Energy.gov (indexed) [DOE]

    temperature ambient (plastic windows) 5 Radiography - Monochromatic x-rays - Absorption of x-rays by the fuel - Ensemble averaged (flux limited) - Room temperature ambient...

  12. X-ray induced optical reflectivity

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Durbin, Stephen M.

    2012-01-01T23:59:59.000Z

    The change in optical reflectivity induced by intense x-ray pulses can now be used to study ultrafast many body responses in solids in the femtosecond time domain. X-ray absorption creates photoelectrons and core level holes subsequently filled by Auger or fluorescence processes, and these excitations ultimately add conduction and valence band carriers that perturb optical reflectivity.Optical absorption associated with band filling and band gap narrowing is shown to explain the basic features found in recent measurements on an insulator (silicon nitride, Si3N4), a semiconductor(gallium arsenide,GaAs), and a metal (gold,Au), obtained with ?100 fs x-ray pulses at 500-2000 eV and probed with 800 nm laser pulses. In particular GaAs exhibits an abrupt drop in reflectivity, persisting only for a time comparable to the x-ray excitation pulse duration, consistent with prompt band gap narrowing.

  13. Columbia University X-Ray Measurements

    E-Print Network [OSTI]

    Columbia University X-Ray Measurements of the Levitated Dipole Experiment J. L. Ellsworth, J. Kesner MIT Plasma Science and Fusion Center D.T. Garnier, A.K. Hansen, M.E. Mauel Columbia University

  14. Small Angle X-Ray Scattering Detector

    DOE Patents [OSTI]

    Hessler, Jan P.

    2004-06-15T23:59:59.000Z

    A detector for time-resolved small-angle x-ray scattering includes a nearly constant diameter, evacuated linear tube having an end plate detector with a first fluorescent screen and concentric rings of first fiber optic bundles for low angle scattering detection and an annular detector having a second fluorescent screen and second fiber optic bundles concentrically disposed about the tube for higher angle scattering detection. With the scattering source, i.e., the specimen under investigation, located outside of the evacuated tube on the tube's longitudinal axis, scattered x-rays are detected by the fiber optic bundles, to each of which is coupled a respective photodetector, to provide a measurement resolution, i.e., dq/q, where q is the momentum transferred from an incident x-ray to an x-ray scattering specimen, of 2% over two (2) orders of magnitude in reciprocal space, i.e., qmax/qmin approx=lO0.

  15. X-ray source for mammography

    DOE Patents [OSTI]

    Logan, Clinton M. (Pleasanton, CA)

    1994-01-01T23:59:59.000Z

    An x-ray source utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms.

  16. X-ray grid-detector apparatus

    DOE Patents [OSTI]

    Boone, John M. (Folsom, CA); Lane, Stephen M. (Oakland, CA)

    1998-01-27T23:59:59.000Z

    A hybrid grid-detector apparatus for x-ray systems wherein a microchannel plate structure has an air-interspaced grid portion and a phosphor/optical fluid-filled grid portion. The grids are defined by multiple adjacent channels separated by lead-glass septa. X-rays entering the air-interspaced grid portion at an angle of impingement upon the septa are attenuated, while non-impinging x-rays pass through to the phosphor/fluid filled portion. X-ray energy is converted to luminescent energy in the phosphor/fluid filled portion and the resultant beams of light are directed out of the phosphor/optical fluid filled portion to an imaging device.

  17. X-ray source for mammography

    DOE Patents [OSTI]

    Logan, C.M.

    1994-12-20T23:59:59.000Z

    An x-ray source is described utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms. 6 figures.

  18. Principles of X-ray Navigation

    SciTech Connect (OSTI)

    Hanson, John Eric; /SLAC

    2006-03-17T23:59:59.000Z

    X-ray navigation is a new concept in satellite navigation in which orientation, position and time are measured by observing stellar emissions in x-ray wavelengths. X-ray navigation offers the opportunity for a single instrument to be used to measure these parameters autonomously. Furthermore, this concept is not limited to missions in close proximity to the earth. X-ray navigation can be used on a variety of missions from satellites in low earth orbit to spacecraft on interplanetary missions. In 1997 the Unconventional Stellar Aspect Experiment (USA) will be launched as part of the Advanced Research and Global Observation Satellite (ARGOS). USA will provide the first platform for real-time experimentation in the field of x-ray navigation and also serves as an excellent case study for the design and manufacturing of space qualified systems in small, autonomous groups. Current techniques for determining the orientation of a satellite rely on observations of the earth, sun and stars in infrared, visible or ultraviolet wavelengths. It is possible to use x-ray imaging devices to provide arcsecond level measurement of attitude based on star patterns in the x-ray sky. This technique is explored with a simple simulation. Collimated x-ray detectors can be used on spinning satellites to provide a cheap and reliable measure of orientation. This is demonstrated using observations of the Crab Pulsar taken by the high Energy Astronomy Observatory (HEAO-1) in 1977. A single instrument concept is shown to be effective, but dependent on an a priori estimate of the guide star intensity and thus susceptible to errors in that estimate. A star scanner based on a differential measurement from two x-ray detectors eliminates the need for an a priori estimate of the guide star intensity. A first order model and a second order model of the two star scanner concepts are considered. Many of the stars that emit in the x-ray regime are also x-ray pulsars with frequency stability approaching a part in 10{sup 9}. By observing these pulsations, a satellite can keep accurate time autonomously. They have demonstrated the acquisition and tracking of the Crab nebula pulsar by simulating the operation of a phase-locked loop.

  19. Compton backscattered collimated x-ray source

    DOE Patents [OSTI]

    Ruth, R.D.; Huang, Z.

    1998-10-20T23:59:59.000Z

    A high-intensity, inexpensive and collimated x-ray source is disclosed for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications. 4 figs.

  20. Compton backscattered collmated X-ray source

    DOE Patents [OSTI]

    Ruth, Ronald D. (Woodside, CA); Huang, Zhirong (Stanford, CA)

    2000-01-01T23:59:59.000Z

    A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

  1. Compton backscattered collimated x-ray source

    DOE Patents [OSTI]

    Ruth, Ronald D. (Woodside, CA); Huang, Zhirong (Stanford, CA)

    1998-01-01T23:59:59.000Z

    A high-intensity, inexpensive and collimated x-ray source for applications such as x-ray lithography is disclosed. An intense pulse from a high power laser, stored in a high-finesse resonator, repetitively collides nearly head-on with and Compton backscatters off a bunched electron beam, having relatively low energy and circulating in a compact storage ring. Both the laser and the electron beams are tightly focused and matched at the interaction region inside the optical resonator. The laser-electron interaction not only gives rise to x-rays at the desired wavelength, but also cools and stabilizes the electrons against intrabeam scattering and Coulomb repulsion with each other in the storage ring. This cooling provides a compact, intense bunch of electrons suitable for many applications. In particular, a sufficient amount of x-rays can be generated by this device to make it an excellent and flexible Compton backscattered x-ray (CBX) source for high throughput x-ray lithography and many other applications.

  2. Transient x-ray diffraction and its application to materials science and x-ray optics

    SciTech Connect (OSTI)

    Hauer, A.A.; Kopp, R.; Cobble, J.; Kyrala, G.; Springer, R. [and others

    1997-12-01T23:59:59.000Z

    Time resolved x-ray diffraction and scattering have been applied to the measurement of a wide variety of physical phenomena from chemical reactions to shock wave physics. Interest in this method has heightened in recent years with the advent of versatile, high power, pulsed x-ray sources utilizing laser plasmas, electron beams and other methods. In this article, we will describe some of the fundamentals involved in time resolved x-ray diffraction, review some of the history of its development, and describe some recent progress in the field. In this article we will emphasize the use of laser-plasmas as the x-ray source for transient diffraction.

  3. Review of Parallel Computing Techniques for Computed Tomography Image Reconstruction

    E-Print Network [OSTI]

    Wang, Ge

    Review of Parallel Computing Techniques for Computed Tomography Image Reconstruction Jun Ni1, 3 representative analytic and iterative reconstruction algorithms for X-ray computed tomography (CT), we address X-ray computed tomography (CT) is one of the most important non-invasive medical imaging techniques

  4. Differential phase contrast X-ray imaging system and components

    DOE Patents [OSTI]

    Stutman, Daniel; Finkenthal, Michael

    2014-07-01T23:59:59.000Z

    A differential phase contrast X-ray imaging system includes an X-ray illumination system, a beam splitter arranged in an optical path of the X-ray illumination system, and a detection system arranged in an optical path to detect X-rays after passing through the beam splitter.

  5. Reflection soft X-ray microscope and method

    DOE Patents [OSTI]

    Suckewer, S.; Skinner, C.H.; Rosser, R.

    1993-01-05T23:59:59.000Z

    A reflection soft X-ray microscope is provided by generating soft X-ray beams, condensing the X-ray beams to strike a surface of an object at a predetermined angle, and focusing the X-ray beams reflected from the surface onto a detector, for recording an image of the surface or near surface features of the object under observation.

  6. Nonlinear X-ray Compton Scattering

    E-Print Network [OSTI]

    Fuchs, Matthias; Chen, Jian; Ghimire, Shambhu; Shwartz, Sharon; Kozina, Michael; Jiang, Mason; Henighan, Thomas; Bray, Crystal; Ndabashimiye, Georges; Bucksbaum, P H; Feng, Yiping; Herrmann, Sven; Carini, Gabriella; Pines, Jack; Hart, Philip; Kenney, Christopher; Guillet, Serge; Boutet, Sebastien; Williams, Garth; Messerschmidt, Marc; Seibert, Marvin; Moeller, Stefan; Hastings, Jerome B; Reis, David A

    2015-01-01T23:59:59.000Z

    X-ray scattering is a weak linear probe of matter. It is primarily sensitive to the position of electrons and their momentum distribution. Elastic X-ray scattering forms the basis of atomic structural determination while inelastic Compton scattering is often used as a spectroscopic probe of both single-particle excitations and collective modes. X-ray free-electron lasers (XFELs) are unique tools for studying matter on its natural time and length scales due to their bright and coherent ultrashort pulses. However, in the focus of an XFEL the assumption of a weak linear probe breaks down, and nonlinear light-matter interactions can become ubiquitous. The field can be sufficiently high that even non-resonant multiphoton interactions at hard X-rays wavelengths become relevant. Here we report the observation of one of the most fundamental nonlinear X-ray-matter interactions, the simultaneous Compton scattering of two identical photons producing a single photon at nearly twice the photon energy. We measure scattered...

  7. Radiographic X-Ray Pulse Jitter

    SciTech Connect (OSTI)

    Mitton, C. V., Good, D. E., Henderson, D. J., Hogge, K. W.

    2011-01-15T23:59:59.000Z

    The Dual Beam Radiographic Facility consists of two identical radiographic sources. Major components of the machines are: Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line, three-cell inductive voltage adder, and rod-pinch diode. The diode pulse has the following electrical specifications: 2.25-MV, 60-kA, 60-ns. Each source has the following x-ray parameters: 1-mm-diameter spot size, 4-rad at 1 m, 50-ns full width half max. The x-ray pulse is measured with PIN diode detectors. The sources were developed to produce high resolution images on single-shot, high-value experiments. For this application it is desirable to maintain a high level of reproducibility in source output. X-ray pulse jitter is a key metric for analysis of reproducibility. We will give measurements of x-ray jitter for each machine. It is expected that x-ray pulse jitter is predominantly due to PFL switch jitter, and therefore a correlation of the two will be discussed.

  8. Oscillations During Thermonuclear X-ray Bursts

    E-Print Network [OSTI]

    Tod E. Strohmayer

    2001-01-12T23:59:59.000Z

    High amplitude, nearly coherent X-ray brightness oscillations during thermonuclear X-ray bursts were discovered with the Rossi X-ray Timing Explorer (RXTE) in early 1996. Spectral and timing evidence strongly supports the conclusion that these oscillations are caused by rotational modulation of the burst emission and that they reveal the spin frequency of neutron stars in low mass X-ray binaries, a long sought goal of X-ray astronomy. Studies carried out over the past year have led to the discovery of burst oscillations in four new sources, bringing to ten the number with confirmed burst oscillations. I review the status of our knowledge of these oscillations and indicate how they can be used to probe the physics of neutron stars. For a few burst oscillation sources it has been proposed that the strongest and most ubiquitous frequency is actually the first overtone of the spin frequency and hence that two nearly antipodal hot spots are present on the neutron star. This inference has important implications for both the physics of thermonuclear burning as well as the mass - radius relation for neutron stars, so its confirmation is crucial. I discuss recent attempts to confirm this hypothesis for 4U 1636-53, the source for which a signal at the putative fundamental (290 Hz) has been claimed.

  9. X-RAY SPECTROMETRY X-Ray Spectrom. 2007; 36: 336342

    E-Print Network [OSTI]

    Limburg, Karin E.

    , Chicago, IL 60637, USA 3 Cornell High Energy Synchrotron Source and School of Applied and EngineeringX-RAY SPECTROMETRY X-Ray Spectrom. 2007; 36: 336­342 Published online in Wiley InterScience (www to establish a breakthrough in high-resolution, simultaneous area mapping of multiple trace elements

  10. In Operando X-ray Diffraction and Transmission X-ray Microscopy of Lithium Sulfur Batteries

    E-Print Network [OSTI]

    Cui, Yi

    In Operando X-ray Diffraction and Transmission X-ray Microscopy of Lithium Sulfur Batteries Johanna Information ABSTRACT: Rechargeable lithium-sulfur (Li-S) batteries hold great potential for high of these batteries for commercial use. The two primary obstacles are the solubility of long chain lithium

  11. X-Ray Data from the X-Ray Data Booklet Online

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Thompson, Albert C.; Attwood, David T.; Gullikson, Eric M.; Howells, Malcolm R.; Kortright, Jeffrey B.; Robinson, Arthur L.; Underwood, James H.; Kim, Kwang-Je; Kirz, Janos; Lindau, Ingolf; Pianetta, Piero; Winick, Herman; Williams, Gwyn P.; Scofield, James H.

    The original X-Ray Data Booklet, published in 1985, became a classic reference source. The online version has been significantly revised and updated to reflect today's science. Hundreds of pages of authoritative data provide the x-ray properties of elements, information on synchrotron radiation, scattering processes, optics and detectors, and other related calculations, formulas, and data tables.

  12. Bomb Detection Using Backscattered X-Rays

    SciTech Connect (OSTI)

    Jacobs, J.; Lockwood, G.; Selph, M; Shope, S.; Wehlburg, J.

    1998-10-01T23:59:59.000Z

    Bomb Detection Using Backscattered X-rays* Currently the most common method to determine the contents of a package suspected of containing an explosive device is to use transmission radiography. This technique requires that an x-ray source and film be placed on opposite sides of the package. This poses a problem if the pachge is placed so that only one side is accessible, such as against a wall. There is also a threat to persomel and property since exTlosive devices may be "booby trapped." We have developed a method to x-ray a paclage using backscattered x-rays. This procedure eliminates the use of film behind the target. All of the detection is done from the same side as the source. When an object is subjected to x-rays, some of them iare scattered back towards the source. The backscattenng of x-rays is propordoml to the atomic number (Z) of the material raised to the 4.1 power. This 24"' dependence allows us to easily distinguish between explosives, wires, timer, batteries, and other bomb components. Using transmission radiography-to image the contents of an unknown package poses some undesirable risks. The object must have an x-ray film placed on the side opposite the x-ray source; this cannot be done without moving the package if it has been placed firmly against a wall or pillar. Therefore it would be extremely usefid to be able to image the contents of a package from only one side, without ever having to disturb the package itself. where E is the energy of the incoming x-ray. The volume of x-rays absorbed is important because it is, of course, directly correlated to the intensity of x-mys that will be scattered. Most of the x-rays that scatter will do so in a genemlly forward direction; however, a small percentage do scatter in a backward direction. Figure 1 shows a diagram of the various fates of x-rays directed into an object. The package that was examined in this ex~enment was an attache case made of pressed fiberboardwith a vinyl covering. It was approxirmtely 36 cm wide by 51 cm long by 13 cm deep. The case was placed on an aluminum sheet under the x-ray source. Because of the laborato~ setup, the attache case was rastered in the y-coordinate direction, while the x-ray source mstered in the x-coordinate direction. However, for field use, the x-ray source would of course raster in both the x- and y-coordinate directions, while the object under interrogation would remain stationary and undisturbed. A mobile system for use by law enforcement agencies or bomb disposal squads needs to be portable and somewhat durable. A 300 kV x-ray source should be sufficient for the task requirements and can be mounted on a mobile system. A robotic carriage could be used to transport the x-ray source and the CCD camera to the proximity of the suspect package. The controlling and data analyzing elements of the system' could then be maintained at a &tie distance from the possible explosive. F@re 8 shows a diagram of a conceptual design of a possible system for this type of use. The use of backscattered x-rays for interrogation of packages that may contain explosive devices has been shown to be feasible inthelaboratory. Usinga 150kVx-ray source anddetectors consisting of plastic scintillating material, all bomb components including the wiring were detectable. However, at this time the process requires more time than is desirable for the situations in which it will most likely be needed. Further development of the technology using CCD cameras, rather than the plastic stint illator detectors, shows promise of leading to a much faster system, as well as one with better resolution. Mounting the x- ray source and the CCD camera on a robotic vehicle while keeping the controlling and analyzing components and the opemting personnel a safe distance away from the suspect package will allow such a package to be examined at low risk to human life.

  13. Frontiers in X-Ray Science

    SciTech Connect (OSTI)

    Linda Young

    2011-02-23T23:59:59.000Z

    The year 2010 marked the fiftieth anniversary of the optical laser and the first anniversary of the world's first hard x-ray free-electron laser, the Linac Coherent Light Source (LCLS) at SLAC. This exciting, new accelerator-based source of x-rays provides peak brilliances roughly a billion times greater than currently available from synchrotron sources such as the Advanced Photon Source at Argonne, and thus explores a qualitatively different parameter space. This talk will describe the first experiments at the LCLS aimed at understanding the nature of high intensity x-ray interactions, related applications in ultrafast imaging on the atomic scale and sketch nascent plans for the extension of both linac and storage-ring based photon sources.

  14. The X-ray/submillimetre link

    E-Print Network [OSTI]

    O. Almaini

    2000-01-07T23:59:59.000Z

    It is widely believed that most of the cosmic X-ray background (XRB) is produced by a vast, hitherto undetected population of obscured AGN. Deep X-ray surveys with Chandra and XMM will soon test this hypothesis. Similarly, recent sub-mm surveys with SCUBA have revealed an analogous population of exceptionally luminous, dust-enshrouded {\\em star-forming} galaxies at high redshift. There is now growing evidence for an intimate link between these obscured populations. There are currently large uncertainties in the models, but several independent arguments lead to the conclusion that a significant fraction of the SCUBA sources ($10-30% $) will contain quasars. Recent observational studies of SCUBA survey sources appear to confirm these predictions, although the relative roles of AGN and star-forming activity in heating the dust are unclear. Forthcoming surveys combining X-ray and sub-mm observations will provide a very powerful tool for disentangling these processes.

  15. X-ray atlas of rheumatic diseases

    SciTech Connect (OSTI)

    Dihlmann, W.

    1986-01-01T23:59:59.000Z

    This atlas comprises instructive X-rays of the various inflammatory rheumatic joint diseases in all stages at the extremities and the spinal column. In addition, the complex pattern of the wide range of arthroses, also known as degenerative rheumatic disease is included. Besides the instructive pointers to X-ray diagnosis, the book is also a guide to differential diagnosis. Hence, this book is actually an X-ray atlas of joint diseases in general. Selected Contents: Introduction: What Does ''Rheumatism'' Actually Mean./Radiographic Methodology in Rheumatic Diseases of the Locomotor System/The Mosaic of Arthritis/Adult Rheumatoid Arthritis/Seronegative Spondylarthritis/Classic Collagen Diseases/Enthesiopathies/Gout-Pseudogout

  16. Combined microstructure x-ray optics

    SciTech Connect (OSTI)

    Barbee, T.W. Jr.

    1989-02-01T23:59:59.000Z

    Multilayers are man-made microstructures which vary in depth and are now of sufficient quality to be used as x-ray, soft x-ray and extreme ultraviolet optics. Gratings are man-made in plane microstructures which have been used as optic elements for most of this century. Joining of these two optical microstructures to form combined microstructure optical microstructures to form combined microstructure optical elements has the potential for greatly enhancing both the throughput and the resolution attainable in these spectral ranges. The characteristics of these new optic elements will be presented and compared to experiment with emphasis on the unique properties of these combined microstructures. These results reported are general in nature and not limited to the soft x-ray or extreme ultraviolet spectral domains and also apply to neutrons. 19 refs., 7 figs., 4 tabs.

  17. X-ray reflectivity and surface roughness

    SciTech Connect (OSTI)

    Ocko, B.M.

    1988-01-01T23:59:59.000Z

    Since the advent of high brightness synchrotron radiation sources there has been a phenomenal growth in the use of x-rays as a probe of surface structure. The technique of x-ray reflectivity is particularly relevant to electrochemists since it is capable of probing the structure normal to an electrode surface in situ. In this paper the theoretical framework for x-ray reflectivity is reviewed and the results from previous non-electrochemistry measurements are summarized. These measurements are from the liquid/air interface (CCl/sub 4/), the metal crystal vacuum interface (Au(100)), and from the liquid/solid interface(liquid crystal/silicon). 34 refs., 5 figs.

  18. Regularization approach for tomosynthesis X-ray inspection

    SciTech Connect (OSTI)

    Tigkos, Konstantinos; Hassler, Ulf; Holub, Wolfgang; Woerlein, Norbert; Rehak, Markus [Fraunhofer Development Center X-ray Technologies (EZRT), Dept. Application Specific Methods and Systems (AMS), Fraunhofer IIS, Flugplatzstraße 75, 90768 Fürth (Germany)

    2014-02-18T23:59:59.000Z

    X-ray inspection is intended to be used as an escalation technique for inspection of carbon fiber reinforced plastics (CFRP) in aerospace applications, especially in case of unclear indications from ultrasonic or other NDT modalities. Due to their large dimensions, most aerospace components cannot be scanned by conventional computed tomography. In such cases, X-ray Laminography may be applied, allowing a pseudo 3D slice-by-slice reconstruction of the sample with Tomosynthesis. However, due to the limited angle acquisition geometry, reconstruction artifacts arise, especially at surfaces parallel to the imaging plane. To regularize the Tomosynthesis approach, we propose an additional prescan of the object to detect outer sample surfaces. We recommend the use of contrasted markers which are temporarily attached to the sample surfaces. The depth position of the markers is then derived from that prescan. As long as the sample surface remains simple, few markers are required to fit the respective object surfaces. The knowledge about this surface may then be used to regularize the final Tomosynthesis reconstruction, performed with markerless projections. Eventually, it can also serve as prior information for an ART reconstruction or to register a CAD model of the sample. The presented work is carried out within the European FP7 project QUICOM. We demonstrate the proposed approach within a simulation study applying an acquisition geometry suited for CFRP part inspection. A practical verification of the approach is planned later in the project.

  19. Radiobiological studies using gamma and x rays.

    SciTech Connect (OSTI)

    Potter, Charles Augustus; Longley, Susan W.; Scott, Bobby R. [Lovelace Respiratory Research Institute, Albuquerque, NM; Lin, Yong [Lovelace Respiratory Research Institute, Albuquerque, NM; Wilder, Julie [Lovelace Respiratory Research Institute, Albuquerque, NM; Hutt, Julie A. [Lovelace Respiratory Research Institute, Albuquerque, NM; Padilla, Mabel T. [Lovelace Respiratory Research Institute, Albuquerque, NM; Gott, Katherine M. [Lovelace Respiratory Research Institute, Albuquerque, NM

    2013-02-01T23:59:59.000Z

    There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

  20. Theoretical standards in x-ray spectroscopies

    SciTech Connect (OSTI)

    Not Available

    1992-01-01T23:59:59.000Z

    We propose to extend our state-of-the-art, ab initio XAFS (X-ray absorption fine structure) codes, FEFF. Our current work has been highly successful in achieving accurate, user-friendly XAFS standards, exceeding the performance of both tabulated standards and other codes by a considerable margin. We now propose to add the capability to treat more complex materials. This includes multiple-scattering, polarization dependence, an approximate treatment of XANES (x-ray absorption near edge structure), and other improvements. We also plan to adapt FEFF to other spectroscopies, e.g. photoelectron diffraction (PD) and diffraction anomalous fine structure (DAFS).

  1. Energy resolved X-ray grating interferometry

    SciTech Connect (OSTI)

    Thuering, T.; Stampanoni, M. [Swiss Light Source, Paul Scherrer Institut, Villigen PSI (Switzerland) [Swiss Light Source, Paul Scherrer Institut, Villigen PSI (Switzerland); Institute for Biomedical Engineering, Swiss Federal Institute of Technology, Zurich (Switzerland); Barber, W. C.; Iwanczyk, J. S. [DxRay, Inc., Northridge, California 91324 (United States)] [DxRay, Inc., Northridge, California 91324 (United States); Seo, Y.; Alhassen, F. [UCSF Physics Research Laboratory, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California 94143 (United States)] [UCSF Physics Research Laboratory, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California 94143 (United States)

    2013-05-13T23:59:59.000Z

    Although compatible with polychromatic radiation, the sensitivity in X-ray phase contrast imaging with a grating interferometer is strongly dependent on the X-ray spectrum. We used an energy resolving detector to quantitatively investigate the dependency of the noise from the spectral bandwidth and to consequently optimize the system-by selecting the best energy band matching the experimental conditions-with respect to sensitivity maximization and, eventually, dose. Further, since theoretical calculations of the spectrum are usually limited due to non-ideal conditions, an energy resolving detector accurately quantifies the spectral changes induced by the interferometer including flux reduction and beam hardening.

  2. X-Ray Nanoimaging: Instruments and Methods

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del SolStrengtheningWildfires may contribute more toConsensusX-RayX-Ray

  3. High efficiency replicated x-ray optics and fabrication method

    DOE Patents [OSTI]

    Barbee, Jr., Troy W. (Palo Alto, CA); Lane, Stephen M. (Oakland, CA); Hoffman, Donald E. (Fremont, CA)

    2001-01-01T23:59:59.000Z

    Replicated x-ray optics are fabricated by sputter deposition of reflecting layers on a super-polished reusable mandrel. The reflecting layers are strengthened by a supporting multilayer that results in stronger stress-relieved reflecting surfaces that do not deform during separation from the mandrel. The supporting multilayer enhances the ability to part the replica from the mandrel without degradation in surface roughness. The reflecting surfaces are comparable in smoothness to the mandrel surface. An outer layer is electrodeposited on the supporting multilayer. A parting layer may be deposited directly on the mandrel before the reflecting surface to facilitate removal of the layered, tubular optic device from the mandrel without deformation. The inner reflecting surface of the shell can be a single layer grazing reflection mirror or a resonant multilayer mirror. The resulting optics can be used in a wide variety of applications, including lithography, microscopy, radiography, tomography, and crystallography.

  4. Bandpass x-ray diode and x-ray multiplier detector

    DOE Patents [OSTI]

    Wang, C.L.

    1982-09-27T23:59:59.000Z

    An absorption-edge of an x-ray absorption filter and a quantum jump of a photocathode determine the bandpass characteristics of an x-ray diode detector. An anode, which collects the photoelectrons emitted by the photocathode, has enhanced amplification provided by photoelectron-multiplying means which include dynodes or a microchannel-plate electron-multiplier. Suppression of undesired high frequency response for a bandpass x-ray diode is provided by subtracting a signal representative of energies above the passband from a signal representative of the overall response of the bandpass diode.

  5. SLAC All Access: X-ray Microscope

    ScienceCinema (OSTI)

    Nelson, Johanna; Liu, Yijin

    2014-06-13T23:59:59.000Z

    SLAC physicists Johanna Nelson and Yijin Liu give a brief overview of the X-ray microscope at the Stanford Synchrotron Radiation Lightsource (SSRL) that is helping improve rechargeable-battery technology by letting researchers peek into the inner workings of batteries as they operate.

  6. Femtosecond X-ray protein nanocrystallography

    SciTech Connect (OSTI)

    Chapman, Henry N.; Fromme, Petra; Barty, Anton; White, Thomas A.; Kirian, Richard A.; Aquila, Andrew; Hunter, Mark S.; Schulz, Joachim; DePonte, Daniel P.; Weierstall, Uwe; Doak, R. Bruce; Maia, Filipe R. N. C.; Martin, Andrew V.; Schlichting, Ilme; Lomb, Lukas; Coppola, Nicola; Shoeman, Robert L.; Epp, Sascha W.; Hartmann, Robert; Rolles, Daniel; Rudenko, Artem; Foucar, Lutz; Kimmel, Nils; Weidenspointner, Georg; Holl, Peter; Liang, Mengning; Barthelmess, Miriam; Caleman, Carl; Boutet, Sebastien; Bogan, Michael J.; Krzywinski, Jacek; Bostedt, Christoph; Bajt, Sasa; Gumprecht, Lars; Rudek, Benedikt; Erk, Benjamin; Schmidt, Carlo; Homke, Andre; Reich, Christian; Pietschner, Daniel; Struder, Lothar; Hauser, Gunter; Gorke, Hubert; Ullrich, Joachim; Herrmann, Sven; Schaller, Gerhard; Schopper, Florian; Soltau, Heike; Kuhnel, Kai-Uwe; Messerschmidt, Marc; Bozek, John D.; Hau-Riege, Stefan P.; Frank, Matthias; Hampton, Christina Y.; Sierra, Raymond G.; Starodub, Dmitri; Williams, Garth J.; Hajdu, Janos; Timneanu, Nicusor; Seibert, M. Marvin; Andreasson, Jakob; Rocker, Andrea; Jonsson, Olof; Svenda, Martin; Stern, Stephan; Nass, Karol; Andritschke, Robert; Schroter, Claus-Dieter; Krasniqi, Faton; Bott, Mario; Schmidt, Kevin E.; Wang, Xiaoyu; Grotjohann, Ingo; Holton, James M.; Barends, Thomas R. M.; Neutze, Richard; Marchesini, Stefano; Fromme, Raimund; Schorb, Sebastian; Rupp, Daniela; Adolph, Marcus; Gorkhover, Tais; Andersson, Inger; Hirsemann, Helmut; Potdevin, Guillaume; Graafsma, Heinz; Nilsson, Bjorn; Spence, John C. H.

    2011-01-01T23:59:59.000Z

    X-ray crystallography provides the vast majority of macromolecular structures, but the success of the method relies on growing crystals of sufficient size. In conventional measurements, the necessary increase in X-ray dose to record data from crystals that are too small leads to extensive damage before a diffraction signal can be recorded. It is particularly challenging to obtain large, well-diffracting crystals of membrane proteins, for which fewer than 300 unique structures have been determined despite their importance in all living cells. Here we present a method for structure determination where single-crystal X-ray diffraction ‘snapshots’ are collected from a fully hydrated stream of nanocrystals using femtosecond pulses from a hard-X-ray free-electron laser, the Linac Coherent Light Source. We prove this concept with nanocrystals of photosystem I, one of the largest membrane protein complexes. More than 3,000,000 diffraction patterns were collected in this study, and a three-dimensional data set was assembled from individual photosystem I nanocrystals (~200?nm to 2??m in size). We mitigate the problem of radiation damage in crystallography by using pulses briefer than the timescale of most damage processes. This offers a new approach to structure determination of macromolecules that do not yield crystals of sufficient size for studies using conventional radiation sources or are particularly sensitive to radiation damage.

  7. Design and characterization of electron beam focusing for X-ray generation in novel medical imaging architecture

    SciTech Connect (OSTI)

    Bogdan Neculaes, V., E-mail: neculaes@research.ge.com; Zou, Yun; Zavodszky, Peter; Inzinna, Louis; Zhang, Xi; Conway, Kenneth; Caiafa, Antonio; Frutschy, Kristopher; Waters, William; De Man, Bruno [GE Global Research, Niskayuna, New York 12309 (United States)] [GE Global Research, Niskayuna, New York 12309 (United States)

    2014-05-15T23:59:59.000Z

    A novel electron beam focusing scheme for medical X-ray sources is described in this paper. Most vacuum based medical X-ray sources today employ a tungsten filament operated in temperature limited regime, with electrostatic focusing tabs for limited range beam optics. This paper presents the electron beam optics designed for the first distributed X-ray source in the world for Computed Tomography (CT) applications. This distributed source includes 32 electron beamlets in a common vacuum chamber, with 32 circular dispenser cathodes operated in space charge limited regime, where the initial circular beam is transformed into an elliptical beam before being collected at the anode. The electron beam optics designed and validated here are at the heart of the first Inverse Geometry CT system, with potential benefits in terms of improved image quality and dramatic X-ray dose reduction for the patient.

  8. Flat panel X-ray detector with reduced internal scattering for improved attenuation accuracy and dynamic range

    DOE Patents [OSTI]

    Smith, Peter D. (Santa Fe, NM); Claytor, Thomas N. (White Rock, NM); Berry, Phillip C. (Albuquerque, NM); Hills, Charles R. (Los Alamos, NM)

    2010-10-12T23:59:59.000Z

    An x-ray detector is disclosed that has had all unnecessary material removed from the x-ray beam path, and all of the remaining material in the beam path made as light and as low in atomic number as possible. The resulting detector is essentially transparent to x-rays and, thus, has greatly reduced internal scatter. The result of this is that x-ray attenuation data measured for the object under examination are much more accurate and have an increased dynamic range. The benefits of this improvement are that beam hardening corrections can be made accurately, that computed tomography reconstructions can be used for quantitative determination of material properties including density and atomic number, and that lower exposures may be possible as a result of the increased dynamic range.

  9. Rise time measurement for ultrafast X-ray pulses

    DOE Patents [OSTI]

    Celliers, Peter M. (Berkeley, CA); Weber, Franz A. (Oakland, CA); Moon, Stephen J. (Tracy, CA)

    2005-04-05T23:59:59.000Z

    A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

  10. Rise Time Measurement for Ultrafast X-Ray Pulses

    DOE Patents [OSTI]

    Celliers, Peter M.; Weber, Franz A.; Moon, Stephen J.

    2005-04-05T23:59:59.000Z

    A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

  11. X-ray microscopy using grazing-incidence reflections optics

    SciTech Connect (OSTI)

    Price, R.H.

    1983-06-30T23:59:59.000Z

    The role of Kirkpatrick-Baez microscopes as the workhorse of the x-ray imaging devices is discussed. This role is being extended with the development of a 22X magnification Kirkpatrick-Baez x-ray microscope with multilayer x-ray mirrors. These mirrors can operate at large angles, high x-ray energies, and have a narrow, well defined x-ray energy bandpass. This will make them useful for numerous experiments. However, where a large solid angle is needed, the Woelter microscope will still be necessary and the technology needed to build them will be useful for many other types of x-ray optics.

  12. X-ray microscopy using grazing-incidence reflection optics

    SciTech Connect (OSTI)

    Price, R.H.

    1981-08-06T23:59:59.000Z

    The Kirkpatrick-Baez microscopes are described along with their role as the workhorse of the x-ray imaging devices. This role is being extended with the development of a 22X magnification Kirkpatrick-Baez x-ray microscope with multilayer x-ray mirrors. These mirrors can operate at large angles, high x-ray energies, and have a narrow, well defined x-ray energy bandpass. This will make them useful for numerous experiments. However, where a large solid angle is needed, the Woelter microscope will still be necessary and the technology needed to build them will be useful for many other types of x-ray optics.

  13. X-ray imaging crystal spectrometer for extended X-ray sources

    DOE Patents [OSTI]

    Bitter, Manfred L. (Princeton, NJ); Fraenkel, Ben (Jerusalem, IL); Gorman, James L. (Bordentown, NJ); Hill, Kenneth W. (Lawrenceville, NJ); Roquemore, A. Lane (Cranbury, NJ); Stodiek, Wolfgang (Princeton, NJ); von Goeler, Schweickhard E. (Princeton, NJ)

    2001-01-01T23:59:59.000Z

    Spherically or toroidally curved, double focusing crystals are used in a spectrometer for X-ray diagnostics of an extended X-ray source such as a hot plasma produced in a tokomak fusion experiment to provide spatially and temporally resolved data on plasma parameters using the imaging properties for Bragg angles near 45. For a Bragg angle of 45.degree., the spherical crystal focuses a bundle of near parallel X-rays (the cross section of which is determined by the cross section of the crystal) from the plasma to a point on a detector, with parallel rays inclined to the main plain of diffraction focused to different points on the detector. Thus, it is possible to radially image the plasma X-ray emission in different wavelengths simultaneously with a single crystal.

  14. X-RAY POINT-SOURCE POPULATIONS CONSTITUTING THE GALACTIC RIDGE X-RAY EMISSION

    SciTech Connect (OSTI)

    Morihana, Kumiko [Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)] [Institute of Physical and Chemical Research (RIKEN), 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Tsujimoto, Masahiro; Ebisawa, Ken [Japan Aerospace Exploration Agency, Institute of Space and Astronautical Science, 3-1-1 Yoshino-dai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan)] [Japan Aerospace Exploration Agency, Institute of Space and Astronautical Science, 3-1-1 Yoshino-dai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan); Yoshida, Tessei, E-mail: morihana@crab.riken.jp [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan)] [National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan)

    2013-03-20T23:59:59.000Z

    Apparently diffuse X-ray emission has been known to exist along the central quarter of the Galactic Plane since the beginning of X-ray astronomy; this is referred to as the Galactic Ridge X-ray emission (GRXE). Recent deep X-ray observations have shown that numerous X-ray point sources account for a large fraction of the GRXE in the hard band (2-8 keV). However, the nature of these sources is poorly understood. Using the deepest X-ray observations made in the Chandra bulge field, we present the result of a coherent photometric and spectroscopic analysis of individual X-ray point sources for the purpose of constraining their nature and deriving their fractional contributions to the hard-band continuum and Fe K line emission of the GRXE. Based on the X-ray color-color diagram, we divided the point sources into three groups: A (hard), B (soft and broad spectrum), and C (soft and peaked spectrum). The group A sources are further decomposed spectrally into thermal and non-thermal sources with different fractions in different flux ranges. From their X-ray properties, we speculate that the group A non-thermal sources are mostly active galactic nuclei and the thermal sources are mostly white dwarf (WD) binaries such as magnetic and non-magnetic cataclysmic variables (CVs), pre-CVs, and symbiotic stars, whereas the group B and C sources are X-ray active stars in flares and quiescence, respectively. In the log N-log S curve of the 2-8 keV band, the group A non-thermal sources are dominant above Almost-Equal-To 10{sup -14} erg cm{sup -2} s{sup -1}, which is gradually taken over by Galactic sources in the fainter flux ranges. The Fe K{alpha} emission is mostly from the group A thermal (WD binaries) and the group B (X-ray active stars) sources.

  15. Fundamental Parameters of Low Mass X-ray Binaries II: X-Ray Persistent Systems

    E-Print Network [OSTI]

    Jorge Casares; Phil Charles

    2005-06-24T23:59:59.000Z

    The determination of fundamental parameters in X-ray luminous (persistent) X-ray binaries has been classically hampered by the large optical luminosity of the accretion disc. New methods, based on irradiation of the donor star and burst oscillations, provide the opportunity to derive dynamical information and mass constraints in many persistent systems for the first time. These techniques are here reviewed and the latest results presented.

  16. Soft x-ray capabilities for investigating the strongly correlated...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-ray, aiming to understand their sciences for applying a new material. In particular, soft x-ray capabilities have been used to obtain microscopic-level understanding of the...

  17. Dawn of x-ray nonlinear optics | Stanford Synchrotron Radiation...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Dawn of x-ray nonlinear optics Wednesday, July 8, 2015 - 3:00pm SLAC, Redtail Hawk Conference Room 108A Speaker: David Reis, PULSE Program Description X-ray free electron lasers...

  18. ALS X-Rays Shine a New Light on Catalysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    times science has used high-brilliance x-rays to look so closely at these reactions. Lead author Dr. David Mueller at the ALS using x-rays to characterize working fuel cells....

  19. A World's Top-10 X-ray Crystal Structure

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A World's Top-10 X-ray Crystal Structure October 7, 2014 Bookmark and Share Philip Coppens An x-ray crystal structure solved by Philip Coppens has been chosen as one of the world's...

  20. Nanofabrication of Diffractive X-ray Optics for Synchrotrons...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the soft x-ray range and down to 15 nm in the multi keV range. For use at x-ray free-electron laser (XFEL) sources, diffractive optics must be capable of withstanding extreme...

  1. Beyond Chandra - the X-ray Surveyor

    E-Print Network [OSTI]

    Weisskopf, Martin C; Tananbaum, Harvey; Vikhlinin, Alexey

    2015-01-01T23:59:59.000Z

    Over the past 16 years, NASA's Chandra X-ray Observatory has provided an unparalleled means for exploring the universe with its half-arcsecond angular resolution. Chandra studies have deepened our understanding of galaxy clusters, active galactic nuclei, galaxies, supernova remnants, planets, and solar system objects addressing almost all areas of current interest in astronomy and astrophysics. As we look beyond Chandra, it is clear that comparable or even better angular resolution with greatly increased photon throughput is essential to address even more demanding science questions, such as the formation and subsequent growth of black hole seeds at very high redshift; the emergence of the first galaxy groups; and details of feedback over a large range of scales from galaxies to galaxy clusters. Recently, NASA Marshall Space Flight Center, together with the Smithsonian Astrophysical Observatory, has initiated a concept study for such a mission named the X-ray Surveyor. This study starts with a baseline payloa...

  2. X-ray radiography for container inspection

    DOE Patents [OSTI]

    Katz, Jonathan I. (Clayton, MO); Morris, Christopher L. (Los Alamos, NM)

    2011-06-07T23:59:59.000Z

    Arrangements of X-ray inspection systems are described for inspecting high-z materials in voluminous objects such as containers. Inspection methods may involve generating a radiographic image based on detected attenuation corresponding to a pulsed beams of radiation transmitted through a voluminous object. The pulsed beams of radiation are generated by a high-energy source and transmitted substantially downward along an incident angle, of approximately 1.degree. to 30.degree., to a vertical axis extending through the voluminous object. The generated radiographic image may be analyzed to detect on localized high attenuation representative of high-z materials and to discriminate high-z materials from lower and intermediate-z materials on the basis of the high density and greater attenuation of high-z material for higher energy (3-10 MeV) X-rays, and the compact nature of threatening masses of fissionable materials.

  3. X-ray mammography with synchrotron radiation

    SciTech Connect (OSTI)

    Burattini, E. (CNR and INFN-Laboratori Nazionali di Frascati, Frascati, Rome (Italy)); Gambaccini, M.; Marziani, M.; Rimondi, O. (Dipartimento di Fisica dell'Universita and Sezione INFN di Ferrara, Ferrara (Italy)); Indovina, P.L. (Dipartimento di Scienze Fisiche dell'Universita and Sezione INFN di Napoli, Naples (Italy)); Pocek, M.; Simonetti, G. (Istituto di Radiologia, Ospedale Sant'Eugenio, Universita di Tor Vergata, Rome (Italy)); Benassi, M.; Tirelli, C. (Istituto Nazionale del Cancro, Regina Elena, Rome (Italy)); Passariello, R. (Cattedra di Radiologia, Universita dell'Aquila, L'Aquila (Italy))

    1992-01-01T23:59:59.000Z

    For the first time in the literature, radiographs of breast phantoms were obtained using several monochromatic synchrotron radiation x-ray beams of selected energy in the range from 14 to 26 keV. In addition, after optimization of the photon energy as a function of the phantom thickness, several mammographs were obtained on surgically removed human breast specimens containing cancer nodules. Comparison between radiographs using a conventional x-ray unit and those obtained of the same specimens utilizing synchrotron monochromatic beams clearly shows that higher contrast and better resolution can be achieved with synchrotron radiation. These results demonstrate the possibility of obtaining radiographs of excised human breast tissue containing a greater amount of radiological information using synchrotron radiation.

  4. X-rays from Supernova Remnants

    E-Print Network [OSTI]

    B. Aschenbach

    2002-08-28T23:59:59.000Z

    A summary of X-ray observations of supernova remnants is presented including the explosion fragment A of the Vela SNR, Tycho, N132D, RX J0852-4622, the Crab Nebula and the 'bulls eye', and SN 1987A, high-lighting the progress made with Chandra and XMM-Newton and touching upon the questions which arise from these observations and which might inspire future research.

  5. Bright X-ray galaxies in SDSS filaments

    E-Print Network [OSTI]

    Tugay, A V

    2013-01-01T23:59:59.000Z

    Eighteen bright X-ray emitting galaxies were found in nearby filaments within SDSS region. Basic X-ray spectral parameters were estimated for these galaxies using power law model with photoelectric absorption. A close pair of X-ray galaxies was found.

  6. Small Angle X-ray Scattering (SAXS) Laboratory Learning Experiences

    E-Print Network [OSTI]

    Meagher, Mary

    .A. & Svergun D.I. (1987). Structure Analysis by Small-Angle X-Ray and Neutron Scattering. NY: Plenum PressSmall Angle X-ray Scattering (SAXS) Laboratory Learning Experiences o - Use of small angle X-ray scattering instrumentation o - Programs that you will use SAXS (BRUKER AXS) PRIMUS (Konarev, Volkov, Koch

  7. Femtosecond laser-electron x-ray source

    DOE Patents [OSTI]

    Hartemann, Frederic V.; Baldis, Hector A.; Barty, Chris P.; Gibson, David J.; Rupp, Bernhard

    2004-04-20T23:59:59.000Z

    A femtosecond laser-electron X-ray source. A high-brightness relativistic electron injector produces an electron beam pulse train. A system accelerates the electron beam pulse train. The femtosecond laser-electron X-ray source includes a high intra-cavity power, mode-locked laser and an x-ray optics system.

  8. X-Ray Interactions with Matter from the Center for X-Ray Optics (CXRO)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Henke, B.L.; Gullikson, E.M.; Davis, J.C.

    The primary interactions of low-energy x-rays within condensed matter, viz. photoabsorption and coherent scattering, are described for photon energies outside the absorption threshold regions by using atomic scattering factors. The atomic scattering factors may be accurately determined from the atomic photoabsorption cross sections using modified Kramers-Kronig dispersion relations. From a synthesis of the currently available experimental data and recent theoretical calculations for photoabsorption, the angle-independent, forward-scattering components of the atomic scattering factors have been thus semiempirically determined and tabulated here for 92 elements and for the region 50-30,000 eV. Atomic scattering factors for all angles of coherent scattering and at the higher photon energies are obtained from these tabulated forward-scattering values by adding a simple angle-dependent form-factor correction. The incoherent scattering contributions that become significant for the light elements at the higher photon energies are similarly determined. The basic x-ray interaction relations that are used in applied x-ray physics are presented here in terms of the atomic scattering factors. The bulk optical constants are also related to the atomic scattering factors. These atomic and optical relations are applied to the detailed calculation of the reflectivity characteristics of a series of practical x-ray mirror, multilayer, and crystal monochromators. Comparisons of the results of this semiempirical,"atom-like", description of x-ray interactions for the low-energy region with those of experiment and ab initio theory are presented.

  9. Calibrating X-ray Imaging Devices for Accurate Intensity Measurement

    SciTech Connect (OSTI)

    Haugh, M. J.

    2011-07-28T23:59:59.000Z

    The purpose of the project presented is to develop methods to accurately calibrate X-ray imaging devices. The approach was to develop X-ray source systems suitable for this endeavor and to develop methods to calibrate solid state detectors to measure source intensity. NSTec X-ray sources used for the absolute calibration of cameras are described, as well as the method of calibrating the source by calibrating the detectors. The work resulted in calibration measurements for several types of X-ray cameras. X-ray camera calibration measured efficiency and efficiency variation over the CCD. Camera types calibrated include: CCD, CID, back thinned (back illuminated), front illuminated.

  10. Apparatus for monitoring X-ray beam alignment

    DOE Patents [OSTI]

    Steinmeyer, P.A.

    1991-10-08T23:59:59.000Z

    A self-contained, hand-held apparatus is provided for monitoring alignment of an X-ray beam in an instrument employing an X-ray source. The apparatus includes a transducer assembly containing a photoresistor for providing a range of electrical signals responsive to a range of X-ray beam intensities from the X-ray beam being aligned. A circuit, powered by a 7.5 VDC power supply and containing an audio frequency pulse generator whose frequency varies with the resistance of the photoresistor, is provided for generating a range of audible sounds. A portion of the audible range corresponds to low X-ray beam intensity. Another portion of the audible range corresponds to high X-ray beam intensity. The transducer assembly may include an a photoresistor, a thin layer of X-ray fluorescent material, and a filter layer transparent to X-rays but opaque to visible light. X-rays from the beam undergoing alignment penetrate the filter layer and excite the layer of fluorescent material. The light emitted from the fluorescent material alters the resistance of the photoresistor which is in the electrical circuit including the audio pulse generator and a speaker. In employing the apparatus, the X-ray beam is aligned to a complete alignment by adjusting the X-ray beam to produce an audible sound of the maximum frequency. 2 figures.

  11. X-ray server : an outline resource for simulations of x-ray diffraction and scattering.

    SciTech Connect (OSTI)

    Stepanov, S.; Biosciences Division

    2004-01-01T23:59:59.000Z

    X-ray Server is a public project operational at the APS since 1997 with the goals to explore novel network technologies for providing wide scientific community with access to personal research results, establishing scientific collaborations, and refining scientific software. The Server provides Web-based access to a number of programs developed by the author in the field of X-ray diffraction and scattering. The software code operates directly on the Server available for use without downloading. Currently seven programs are accessible that have been used more than 85,000 times. This report discusses the Server philosophy, provides an overview of the physical models and algorithms beneath the codes and demonstrates some applications of the programs. It is shown with examples and statistics how the Server goals are achieved. The plans for further X-ray Server development are outlined.

  12. Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications

    SciTech Connect (OSTI)

    Haboub, Abdel; MacDowell, Alastair; Marchesini, Stefano; Parkinson, Dilworth

    2013-06-01T23:59:59.000Z

    Employing a coded aperture pattern in front of a charge couple device pixilated detector (CCD) allows for imaging of fluorescent x-rays (6-25KeV) being emitted from samples irradiated with x-rays. Coded apertures encode the angular direction of x-rays and allow for a large Numerical Aperture x- ray imaging system. The algorithm to develop the self-supported coded aperture pattern of the Non Two Holes Touching (NTHT) pattern was developed. The algorithms to reconstruct the x-ray image from the encoded pattern recorded were developed by means of modeling and confirmed by experiments. Samples were irradiated by monochromatic synchrotron x-ray radiation, and fluorescent x-rays from several different test metal samples were imaged through the newly developed coded aperture imaging system. By choice of the exciting energy the different metals were speciated.

  13. HgMn Stars as apparent X-ray emitters

    E-Print Network [OSTI]

    Hubrig, S; Mathys, G

    1998-01-01T23:59:59.000Z

    In the ROSAT all-sky survey 11 HgMn stars were detected as soft X-ray emitters (Berghoefer, Schmitt & Cassinelli 1996). Prior to ROSAT, X-ray observations with the Einstein Observatory had suggested that stars in the spectral range B5-A7 are devoid of X-ray emission. Since there is no X-ray emitting mechanism available for these stars (also not for HgMn stars), the usual argument in the case of an X-ray detected star of this spectral type is the existence of an unseen low-mass companion which is responsible for the X-ray emission. The purpose of the present work is to use all available data for our sample of X-ray detected HgMn stars and conclude on the nature of possible companions.

  14. X-ray emission properties of galaxies in Abell 3128

    E-Print Network [OSTI]

    Russell J. Smith

    2003-07-15T23:59:59.000Z

    We use archival Chandra X-ray Observatory data to investigate X-ray emission from early-type galaxies in the rich z=0.06 cluster Abell 3128. By combining the X-ray count-rates from an input list of optically-selected galaxies, we obtain a statistical detection of X-ray flux, unbiased by X-ray selection limits. Using 87 galaxies with reliable Chandra data, X-ray emission is detected for galaxies down to M_B ~ -19.0, with only an upper limit determined for galaxies at M_B ~ -18.3. The ratio of X-ray to optical luminosities is consistent with recent determinations of the low-mass X-ray binary content of nearby elliptical galaxies. Taken individually, in contrast, we detect significant (3sigma) flux for only six galaxies. Of these, one is a foreground galaxy, while two are optically-faint galaxies with X-ray hardness ratios characteristic of active galactic nuclei. The remaining three detected galaxies are amongst the optically-brightest cluster members, and have softer X-ray spectra. Their X-ray flux is higher than that expected from X-ray binaries, by a factor 2-10; the excess suggests these galaxies have retained their hot gaseous haloes. The source with the highest L_X / L_B ratio is of unusual optical morphology with prominent sharp-edged shells. Notwithstanding these few exceptions, the cluster population overall exhibits X-ray properties consistent with their emission being dominated by X-ray binaries. We conclude that in rich cluster environments, interaction with the ambient intra-cluster medium acts to strip most galaxies of their hot halo gas.

  15. Scanning Transmission X-ray Microscopy: Applications in Atmospheric Aerosol Research

    E-Print Network [OSTI]

    Moffet, Ryan C.

    2011-01-01T23:59:59.000Z

    2-ID-B intermediate-energy scanning X-ray microscope at theW. D. , Morrison, G. R. et al. Scanning transmission X-rayX-ray spectromicroscopy with the scanning transmission X-ray

  16. X-ray generation using carbon nanotubes

    E-Print Network [OSTI]

    Parmee, Richard J.; Collins, Clare M.; Milne, William I.; Cole, Matthew T.

    2015-01-06T23:59:59.000Z

    of these sys- tems are illustrated in Figure 2(b) also outlines the principle mode of operation. Here, sealed in an inexpensive and eas- ily fabricated evacuated glass or ceramic envelope, the elec- trons are liberated from a metallic filament, often made... - ment of CNT-based FE sources is provided in [152]. Here we provide a condensed review of the progress, as it pertains to X-ray sources, since then. CNTs have some of the highest attainable aspect ratios, high thermal conductivity, low chemical...

  17. The BMW X-ray Cluster Survey

    E-Print Network [OSTI]

    Alberto Moretti; Luigi Guzzo; Sergio Campana; Stefano Covino; Davide Lazzati; Marcella Longhetti; Emilio Molinari; Maria Rosa Panzera; Gianpiero Tagliaferri; Ian Dell'Antonio

    2001-03-21T23:59:59.000Z

    We describe the main features of the BMW survey of serendipitous X-ray clusters, based on the still unexploited ROSAT-HRI archival observations. The sky coverage, surface density and first deep optical CCD images of the candidates indicate that this sample can represent an excellent complement to the existing PSPC deep cluster surveys and will provide us with a fully independent probe of the evolution of the cluster abundance, in addition to significantly increasing the number of clusters known at z>0.6.

  18. The BMW X-ray Cluster Survey

    E-Print Network [OSTI]

    Moretti, A; Campana, S; Covino, S; Lazzati, D; Longhetti, M; Molinari, E; Panzera, M R; Tagliaferri, G; Dell'Antonio, I P; Moretti, Alberto; Guzzo, Luigi; Campana, Sergio; Covino, Stefano; Lazzati, Davide; Longhetti, Marcella; Molinari, Emilio; Panzera, Maria Rosa; Tagliaferri, Gianpiero; Antonio, Ian Dell'

    2001-01-01T23:59:59.000Z

    We describe the main features of the BMW survey of serendipitous X-ray clusters, based on the still unexploited ROSAT-HRI archival observations. The sky coverage, surface density and first deep optical CCD images of the candidates indicate that this sample can represent an excellent complement to the existing PSPC deep cluster surveys and will provide us with a fully independent probe of the evolution of the cluster abundance, in addition to significantly increasing the number of clusters known at z>0.6.

  19. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |Is Your HomeLatest News ReleasesDepartmentLendingX-Ray Imaging in

  20. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |Is Your HomeLatest News ReleasesDepartmentLendingX-Ray Imaging

  1. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |Is Your HomeLatest News ReleasesDepartmentLendingX-Ray

  2. Lensless X-Ray Imaging in Reflection

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh SchoolIn12electron 9 5 -ofLearningLensless ImagingLensless X-Ray

  3. Small Angle X-ray Scattering

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over Our Instagram Secretary Moniz9Morgan ManagingW.tepidumAngle X-ray Scattering

  4. SMB, X-ray Absorption Spectroscopy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection245C Unlimited ReleaseWelcome to theAbsorption Spectroscopy X-ray

  5. Medical Imaging Computed Tomography (CT)

    E-Print Network [OSTI]

    Massey, Thomas N.

    Module 10 Medical Imaging · X-rays · Computed Tomography (CT) · Positron Emission Tomography (PET Sources PET-TOF #12;Four Sources PET #12;Four Sources PET-TOF #12;PET Scan MRI CT scan #12;Endocrine Gland,000 pixels! #12;Modern Example of CT Scan with the addition of Surface Shading Standard CT With Surface

  6. X-ray emission from Saturn

    E-Print Network [OSTI]

    Ness, J U; Wolk, S J; Dennerl, K; Burwitz, V

    2004-01-01T23:59:59.000Z

    We report the first unambiguous detection of X-ray emission originating from Saturn with a Chandra observation, duration 65.5 ksec with ACIS-S3. Beyond the pure detection we analyze the spatial distribution of X-rays on the planetary surface, the light curve, and some spectral properties. The detection is based on 162 cts extracted from the ACIS-S3 chip within the optical disk of Saturn. We found no evidence for smaller or larger angular extent. The expected background level is 56 cts, i.e., the count rate is (1.6 +- 0.2) 10^-3 cts/s. The extracted photons are rather concentrated towards the equator of the apparent disk, while both polar caps have a relative photon deficit. The inclination angle of Saturn during the observation was -27 degrees, so that the northern hemisphere was not visible during the complete observation. In addition, it was occulted by the ring system. We found a small but significant photon excess at one edge of the ring system. The light curve shows a small dip twice at identical phases,...

  7. The variability properties of X-ray steep and X-ray flat quasars

    E-Print Network [OSTI]

    Fabrizio Fiore; Ari Laor; Martin Elvis; Fabrizio Nicastro; Emanuele Giallongo

    1998-03-20T23:59:59.000Z

    We have studied the variability of 6 low redshift, radio quiet `PG' quasars on three timescales (days, weeks, and months) using the ROSAT HRI. The quasars were chosen to lie at the two extreme ends of the ROSAT PSPC spectral index distribution and hence of the H$\\beta$ FWHM distribution. The observation strategy has been carefully designed to provide even sampling on these three basic timescales and to provide a uniform sampling among the quasars We have found clear evidence that the X-ray steep, narrow H_beta, quasars systematically show larger amplitude variations than the X-ray flat broad H_beta quasars on timescales from 2 days to 20 days. On longer timescales we do not find significant differences between steep and flat quasars, although the statistics are poorer. We suggest that the above correlation between variability properties and spectral steepness can be explained in a scenario in which the X-ray steep, narrow line objects are in a higher L/L_Edd state with respect to the X-ray flat, broad line objects. We evaluated the power spectrum of PG1440+356 (the brigthest quasar in our sample) between 2E-7 and 1E-3 Hz, where it goes into the noise. The power spectrum is roughly consistent with a 1/f law between 1E-3 and 2E-6 Hz. Below this frequency it flattens significantly.

  8. Soft x-ray reduction camera for submicron lithography

    DOE Patents [OSTI]

    Hawryluk, Andrew M. (2708 Rembrandt Pl., Modesto, CA 95356); Seppala, Lynn G. (7911 Mines Rd., Livermore, CA 94550)

    1991-01-01T23:59:59.000Z

    Soft x-ray projection lithography can be performed using x-ray optical components and spherical imaging lenses (mirrors), which form an x-ray reduction camera. The x-ray reduction is capable of projecting a 5x demagnified image of a mask onto a resist coated wafer using 4.5 nm radiation. The diffraction limited resolution of this design is about 135 nm with a depth of field of about 2.8 microns and a field of view of 0.2 cm.sup.2. X-ray reflecting masks (patterned x-ray multilayer mirrors) which are fabricated on thick substrates and can be made relatively distortion free are used, with a laser produced plasma for the source. Higher resolution and/or larger areas are possible by varying the optic figures of the components and source characteristics.

  9. Fabrication process for a gradient index x-ray lens

    DOE Patents [OSTI]

    Bionta, Richard M. (Livermore, CA); Makowiecki, Daniel M. (Livermore, CA); Skulina, Kenneth M. (Livermore, CA)

    1995-01-01T23:59:59.000Z

    A process for fabricating high efficiency x-ray lenses that operate in the 0.5-4.0 keV region suitable for use in biological imaging, surface science, and x-ray lithography of integrated circuits. The gradient index x-ray optics fabrication process broadly involves co-sputtering multi-layers of film on a wire, followed by slicing and mounting on block, and then ion beam thinning to a thickness determined by periodic testing for efficiency. The process enables the fabrication of transmissive gradient index x-ray optics for the 0.5-4.0 keV energy range. This process allows the fabrication of optical elements for the next generation of imaging and x-ray lithography instruments m the soft x-ray region.

  10. Fabrication process for a gradient index x-ray lens

    DOE Patents [OSTI]

    Bionta, R.M.; Makowiecki, D.M.; Skulina, K.M.

    1995-01-17T23:59:59.000Z

    A process is disclosed for fabricating high efficiency x-ray lenses that operate in the 0.5-4.0 keV region suitable for use in biological imaging, surface science, and x-ray lithography of integrated circuits. The gradient index x-ray optics fabrication process broadly involves co-sputtering multi-layers of film on a wire, followed by slicing and mounting on block, and then ion beam thinning to a thickness determined by periodic testing for efficiency. The process enables the fabrication of transmissive gradient index x-ray optics for the 0.5-4.0 keV energy range. This process allows the fabrication of optical elements for the next generation of imaging and x-ray lithography instruments in the soft x-ray region. 13 figures.

  11. Density gradient free electron collisionally excited X-ray laser

    DOE Patents [OSTI]

    Campbell, Edward M. (Pleasanton, CA); Rosen, Mordecai D. (Berkeley, CA)

    1989-01-01T23:59:59.000Z

    An operational X-ray laser (30) is provided that amplifies 3p-3s transition X-ray radiation along an approximately linear path. The X-ray laser (30) is driven by a high power optical laser. The driving line focused optical laser beam (32) illuminates a free-standing thin foil (34) that may be associated with a substrate (36) for improved structural integrity. This illumination produces a generally cylindrically shaped plasma having an essentially uniform electron density and temperature, that exists over a long period of time, and provides the X-ray laser gain medium. The X-ray laser (30) may be driven by more than one optical laser beam (32, 44). The X-ray laser (30) has been successfully demonstrated to function in a series of experimental tests.

  12. Soft x-ray reduction camera for submicron lithography

    DOE Patents [OSTI]

    Hawryluk, A.M.; Seppala, L.G.

    1991-03-26T23:59:59.000Z

    Soft x-ray projection lithography can be performed using x-ray optical components and spherical imaging lenses (mirrors), which form an x-ray reduction camera. The x-ray reduction is capable of projecting a 5x demagnified image of a mask onto a resist coated wafer using 4.5 nm radiation. The diffraction limited resolution of this design is about 135 nm with a depth of field of about 2.8 microns and a field of view of 0.2 cm[sup 2]. X-ray reflecting masks (patterned x-ray multilayer mirrors) which are fabricated on thick substrates and can be made relatively distortion free are used, with a laser produced plasma for the source. Higher resolution and/or larger areas are possible by varying the optic figures of the components and source characteristics. 9 figures.

  13. Density gradient free electron collisionally excited x-ray laser

    DOE Patents [OSTI]

    Campbell, E.M.; Rosen, M.D.

    1984-11-29T23:59:59.000Z

    An operational x-ray laser is provided that amplifies 3p-3s transition x-ray radiation along an approximately linear path. The x-ray laser is driven by a high power optical laser. The driving line focused optical laser beam illuminates a free-standing thin foil that may be associated with a substrate for improved structural integrity. This illumination produces a generally cylindrically shaped plasma having an essentially uniform electron density and temperature, that exists over a long period of time, and provides the x-ray laser gain medium. The x-ray laser may be driven by more than one optical laser beam. The x-ray laser has been successfully demonstrated to function in a series of experimental tests.

  14. Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction

    E-Print Network [OSTI]

    O'Sullivan, Joseph A.

    Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies September 2002 X-ray computed tomography CT images of patients bearing metal intracavitary applicators of Physicists in Medicine. DOI: 10.1118/1.1509443 Key words: x-ray transmission computed tomography, metal

  15. Ultra-short wavelength x-ray system

    DOE Patents [OSTI]

    Umstadter, Donald (Ann Arbor, MI); He, Fei (Ann Arbor, MI); Lau, Yue-Ying (Potomac, MD)

    2008-01-22T23:59:59.000Z

    A method and apparatus to generate a beam of coherent light including x-rays or XUV by colliding a high-intensity laser pulse with an electron beam that is accelerated by a synchronized laser pulse. Applications include x-ray and EUV lithography, protein structural analysis, plasma diagnostics, x-ray diffraction, crack analysis, non-destructive testing, surface science and ultrafast science.

  16. Legacy of the X-Ray Laser Program

    SciTech Connect (OSTI)

    Nilsen, J.

    1993-08-06T23:59:59.000Z

    The X-Ray Laser Program has evolved from a design effort focusing on developing a Strategic Defense Initiative weapon that protects against Soviet ICBMs to a scientific project that is producing new technologies for industrial and medical research. While the great technical successes and failures of the X-ray laser itself cannot be discussed, this article presents the many significant achievements made as part of the X-ray laser effort that are now being used for other applications at LLNL.

  17. Sum rules for polarization-dependent x-ray absorption

    SciTech Connect (OSTI)

    Ankudinov, A.; Rehr, J.J. (Department of Physics, FM-15, University of Washington, Seattle, Washington 98195 (United States))

    1995-01-01T23:59:59.000Z

    A complete set of sum rules is obtained for polarization-dependent x-ray-absorption fine structure and x-ray circular magnetic dichroism (CMD), analogous to those for CMD derived by Thole [ital et] [ital al]. These sum rules relate x-ray-absorption coefficients to the ground-state expectation values of various operators. Problems with applying these sum rules are discussed.

  18. A laser triggered vacuum spark x-ray lithography source

    E-Print Network [OSTI]

    Keating, Richard Allen

    1987-01-01T23:59:59.000Z

    ionized state or the physical processes occurring 15 in a high temperature plasma. There are many advantages to the use of the vacuum spark as an x-ray source; the simplicity of the machine is one. The x-ray output is within the range usable for x-ray... spark apparatus ha- been studied here to determine its applicability to x-ray lithography. A capacitor which stored approximately 3 KJ supplied most of the energy for the plasma. A Nd-YAG laser was used to supply electrons and metallic atoms...

  19. X-ray compass for determining device orientation

    DOE Patents [OSTI]

    Da Silva, Luiz B. (Danville, CA); Matthews, Dennis L. (Moss Beach, CA); Fitch, Joseph P. (Livermore, CA); Everett, Matthew J. (Pleasanton, CA); Colston, Billy W. (Livermore, CA); Stone, Gary F. (Livermore, CA)

    1999-01-01T23:59:59.000Z

    An apparatus and method for determining the orientation of a device with respect to an x-ray source. In one embodiment, the present invention is coupled to a medical device in order to determine the rotational orientation of the medical device with respect to the x-ray source. In such an embodiment, the present invention is comprised of a scintillator portion which is adapted to emit photons upon the absorption of x-rays emitted from the x-ray source. An x-ray blocking portion is coupled to the scintillator portion. The x-ray blocking portion is disposed so as to vary the quantity of x-rays which penetrate the scintillator portion based upon the particular rotational orientation of the medical device with respect to the x-ray source. A photon transport mechanism is also coupled to the scintillator portion. The photon transport mechanism is adapted to pass the photons emitted from the scintillator portion to an electronics portion. By analyzing the quantity of the photons, the electronics portion determines the rotational orientation of the medical device with respect to the x-ray source.

  20. X-ray compass for determining device orientation

    DOE Patents [OSTI]

    Da Silva, L.B.; Matthews, D.L.; Fitch, J.P.; Everett, M.J.; Colston, B.W.; Stone, G.F.

    1999-06-15T23:59:59.000Z

    An apparatus and method for determining the orientation of a device with respect to an x-ray source are disclosed. In one embodiment, the present invention is coupled to a medical device in order to determine the rotational orientation of the medical device with respect to the x-ray source. In such an embodiment, the present invention is comprised of a scintillator portion which is adapted to emit photons upon the absorption of x-rays emitted from the x-ray source. An x-ray blocking portion is coupled to the scintillator portion. The x-ray blocking portion is disposed so as to vary the quantity of x-rays which penetrate the scintillator portion based upon the particular rotational orientation of the medical device with respect to the x-ray source. A photon transport mechanism is also coupled to the scintillator portion. The photon transport mechanism is adapted to pass the photons emitted from the scintillator portion to an electronics portion. By analyzing the quantity of the photons, the electronics portion determines the rotational orientation of the medical device with respect to the x-ray source. 25 figs.

  1. Unexpected Angular Dependence of X-Ray Magnetic Linear Dichroism

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    axes must be taken into account for accurate interpretation of XMLD data. Magnetism and X Rays The ancient Greeks and also the Chinese knew about strange and rare...

  2. Generation of Coherent X-Ray Radiation Through Modulation Compression

    E-Print Network [OSTI]

    Qiang, Ji

    2011-01-01T23:59:59.000Z

    ultra-short coherent X-ray radiation by controlling the fraction of the beam that can be properly unchirped using a few-cycle laser

  3. The Daguerreotype and the X-ray: A Deep Look

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    - likely will play a crucial role in future scientific breakthroughs. Last week, hers was the first daguerreotype to undergo powerful x-ray analysis in a collaboration...

  4. Resonant Soft X-Ray Scattering of Tri-Block Copolymers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection TechnicalResonant Soft X-Ray Scattering of Tri-Block Copolymers Print

  5. X-ray laser system, x-ray laser and method

    DOE Patents [OSTI]

    London, Richard A. (Oakland, CA); Rosen, Mordecai D. (Berkeley, CA); Strauss, Moshe (Omer, IL)

    1992-01-01T23:59:59.000Z

    Disclosed is an x-ray laser system comprising a laser containing generating means for emitting short wave length radiation, and means external to said laser for energizing said generating means, wherein when the laser is in an operative mode emitting radiation, the radiation has a transverse coherence length to width ratio of from about 0.05 to 1. Also disclosed is a method of adjusting the parameters of the laser to achieve the desired coherence length to laser width ratio.

  6. Constraints on jet X-ray emission in low/hard state X-ray binaries

    E-Print Network [OSTI]

    Thomas J. Maccarone

    2005-03-31T23:59:59.000Z

    We show that the combination of the similarities between the X-ray properties of low luminosity accreting black holes and accreting neutron stars, combined with the differences in their radio properties argues that the X-rays from these systems are unlikely to be formed in the relativistic jets. Specifically, the spectra of extreme island state neutron stars and low/hard state black holes are known to be indistinguishable, while the power spectra from these systems are known to show only minor differences beyond what would be expected from scaling the characteristic variability frequencies by the mass of the compact object. The spectral and temporal similarities thus imply a common emission mechanism that has only minor deviations from having all key parameters scaling linearly with the mass of the compact object, while we show that this is inconsistent with the observations that the radio powers of neutron stars are typically about 30 times lower than those of black holes at the same X-ray luminosity. We also show that an abrupt luminosity change would be expected when a system makes a spectral state transition from a radiatively inefficient jet dominated accretion flow to a thin disk dominated flow, but that such a change is not seen.

  7. Isotropic star in low-mass X-ray binaries and X-ray pulsars

    E-Print Network [OSTI]

    Mehedi Kalam; Sk. Monowar Hossein; Sajahan Molla

    2014-10-01T23:59:59.000Z

    We present a model for compact stars in the low mass X-ray binaries(LMXBs) and X-ray pulsars using a metric given by John J. Matese and Patrick G. Whitman \\citep{Matese and Whitman1980}. Here the field equations are reduced to a system of two algebraic equations considering the isotropic pressure. Compact star candidates 4U 1820-30(radius=10km) in LMXBs, and Her X-1(radius=7.7km), SAX J 1808.4-3658(SS1)(radius=7.07km) and SAX J 1808.4-3658(SS2)(radius=6.35km) in X-ray pulsars satisfy all the energy conditions, TOV-equation and stability condition. From our model, we have derived mass($M$), central density($\\rho_{0}$), suface density($\\rho_{b}$), central pressure($p_{0}$), surface pressure($p_{b}$) and surface red-shift($Z_{s}$) of the above mentioned stars, which are very much consistant with the observed/reported datas\\citep{N. K. Glendenning1997,Gondek2000}. We have also observe the adiabatic index($\\gamma$>4/3) of the above steller objects.

  8. Residual stress measurement using X-ray diffraction 

    E-Print Network [OSTI]

    Anderoglu, Osman

    2005-02-17T23:59:59.000Z

    .3.6.2. Synchrotron Diffraction.........................................................................9 II. FUNDAMENTAL CONCEPTS IN X-RAY DIFFRACTION.....................................12 2.1. X-ray Source... radiations ...................................................................16 Table 2.2 Structure factors and reflection conditions ...................................................20 Table 4.1 Chemical composition of SS316...

  9. Ultrafast x-rays: radiographing magnetism Project overview

    E-Print Network [OSTI]

    Haviland, David

    , head of the ultrafast magnetism group. Stanford PULSE is a worldwide renowned centre for ultrafast1 Ultrafast x-rays: radiographing magnetism Project overview The main purpose of the proposed, it is now possible to achieve x-ray pulses that are a few femtoseconds long and that are focused within

  10. High resolution energy-sensitive digital X-ray

    DOE Patents [OSTI]

    Nygren, David R. (Berkeley, CA)

    1995-01-01T23:59:59.000Z

    An apparatus and method for detecting an x-ray and for determining the depth of penetration of an x-ray into a semiconductor strip detector. In one embodiment, a semiconductor strip detector formed of semiconductor material is disposed in an edge-on orientation towards an x-ray source such that x-rays From the x-ray source are incident upon and substantially perpendicular to the front edge of the semiconductor strip detector. The semiconductor strip detector is formed of a plurality of segments. The segments are coupled together in a collinear arrangement such that the semiconductor strip detector has a length great enough such that substantially all of the x-rays incident on the front edge of the semiconductor strip detector interact with the semiconductor material which forms the semiconductor strip detector. A plurality of electrodes are connected to the semiconductor strip detect or such that each one of the of semiconductor strip detector segments has at least one of the of electrodes coupled thereto. A signal processor is also coupled to each one of the electrodes. The present detector detects an interaction within the semiconductor strip detector, between an x-ray and the semiconductor material, and also indicates the depth of penetration of the x-ray into the semiconductor strip detector at the time of the interaction.

  11. Residual stress measurement using X-ray diffraction

    E-Print Network [OSTI]

    Anderoglu, Osman

    2005-02-17T23:59:59.000Z

    -rays..............................................................................................16 2.4. Bragg's Law ..........................................................................................................18 2.5. Diffractometer Geometry... Figure 2.2 Schematic showing the basic components of a modern x-ray tube. Beryllium window is highly transparent to x-rays...............................15 Figure 2.3 Coherent scattering from an electron to a point P...

  12. Shad-o-Snap X-Ray Camera Hardware Manual

    E-Print Network [OSTI]

    -o-Snap x-ray camera is a complete, stand-alone x-ray imaging device featuring "smart" microprocessor-controlled camera electronics and a convenient USB interface. The plug- and-play interface allows easy control by the silicon photodiodes. The Shad-o-Snap camera also includes electronics to digitize the video signal

  13. Measurement and characterization of x-ray spot size

    SciTech Connect (OSTI)

    Mueller, K.H.

    1989-01-01T23:59:59.000Z

    In planning an x-ray imaging experiment one must have an accurate model of the imaging system to obtain optimum results. The blurring caused by the finite size of the x-ray source is often the least understood element in the system. We have developed experimental and analytical methods permitting accurate measurement and modeling of the x-ray source. The model offers a simple and accurate way to optimize the radiographic geometry for any given experimental requirement (i.e., resolution and dose at detector). Any text on radiography will mention the effects of the finite size of the x-ray source on image quality and how one can minimize this influence by the choice of a small radiographic magnification. The film blur (independent of the source blur) is often treated as a single number and combined with an effective blur dimension for the x-ray source to give a total blur on the film. In this paper, we will develop a treatment of x-ray sources based on the modulation transfer function (MTF). This approach allows us to infer the spatial distribution function of the electron beam that produces the bremsstrahlung x-rays and to predict the performance of an x-ray imaging system if we know the MTF of the detector. This treatment is much more accurate than a single number characterization. 4 refs., 7 figs.

  14. Fourteenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Fourteenth National School on Neutron and X-ray Scattering August 12 - 25, 2012 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major Ridge National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang

  15. Neutron and X-ray Scattering Study of Magnetic Manganites

    E-Print Network [OSTI]

    Boothroyd, Andrew

    Neutron and X-ray Scattering Study of Magnetic Manganites Graeme Eoin Johnstone A Thesis submitted are performed using a variety of neutron scattering and x-ray scattering techniques. The electronic ground for analysing the results of the polarised neutron scattering experiment. There are a large number of people who

  16. Tenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Tenth National School on Neutron and X-ray Scattering September 24 - October 11, 2008 at Argonne of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  17. National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    15th National School on Neutron and X-ray Scattering August 10 - 24, 2013 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major Ridge National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang

  18. Thirteenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Thirteenth National School on Neutron and X-ray Scattering June 11 ­ June 25, 2011 at Argonne of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  19. Sixteenth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Sixteenth National School on Neutron and X-ray Scattering June 14-28, 2014 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major's Neutron Scattering Science Division. Scientific Directors: Suzanne G.E. te Velthuis, Esen Ercan Alp

  20. Twelfth National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    Twelfth National School on Neutron and X-ray Scattering June 12 ­ June 26, 2010 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  1. National School on Neutron and X-ray Scattering

    E-Print Network [OSTI]

    Pennycook, Steve

    National School on Neutron and X-ray Scattering May 30 ­ June 13, 2009 at Argonne National of the National School on Neutron and X-ray Scattering is to educate graduate students on the utilization of major National Laboratory's Neutron Scattering Science Division. Scientific Directors: Jonathan C. Lang, Suzanne

  2. Electromagnetic Application: X-RAY Alawi H. Ba-Surrah

    E-Print Network [OSTI]

    Masoudi, Husain M.

    , Pulyui published high-quality x-ray images in journals in Paris and London. · Nikola Tesla In April 1887, Nikola Tesla began to investigate X-rays using high voltages and tubes of his own design, as well. The principle behind Tesla's device is called the Bremsstrahlung process, in which a high-energy secondary X

  3. Chandra X-ray Analysis of Galaxy Cluster A168

    E-Print Network [OSTI]

    Yanbin Yang; Zhiying Huo; Xu Zhou; Suijian Xue; Shude Mao; Jun Ma; Jiansheng Chen

    2004-06-29T23:59:59.000Z

    We present Chandra X-ray observations of galaxy cluster A168 (z=0.045). Two X-ray peaks with a projected distance of 676 kpc are found to be located close to two dominant galaxies, respectively. Both peaks are significantly offset from the peak of the number density distribution of galaxies. This suggests that A168 consists of two subclusters, a northern subcluster (A168N) and a southern subcluster (A168S). Further X-ray imaging analysis reveals that (1) the X-ray isophotes surrounding the two X-ray peaks are heavily distorted, (2) an elongated and ontinuous filament connects the two X-ray peaks. These suggest that strong interactions have occurred between the two subclusters. Spectral analysis shows that A168 has a mean temperature of 2.53 +/- 0.09 keV and a mean metallicity of 0.31 +/- 0.04 Z_{solar}. The metallicity is roughly a constant across the cluster but the temperature shows some systematic variations. Most X-ray, optical and radio properties of A168 are consistent with it being an off-axis merger several Gyrs after a core passage, although detailed numerical simulations are required to see whether the observed properties, in particular the significant offset between the optical and X-ray centers, can be reproduced in such a scenario.

  4. Millisecond oscillations during thermonuclear X-ray bursts

    E-Print Network [OSTI]

    Muno, Michael Patrick, 1975-

    2002-01-01T23:59:59.000Z

    I analyze 68 oscillation trains detected in a search of 159 thermonuclear bursts from eight neutron star X-ray binaries observed with the Rossi X-ray Timing Explorer. I use all data that were public as of September 2001. ...

  5. Broadband high resolution X-ray spectral analyzer

    DOE Patents [OSTI]

    Silver, E.H.; Legros, M.; Madden, N.W.; Goulding, F.; Landis, D.

    1998-07-07T23:59:59.000Z

    A broad bandwidth high resolution X-ray fluorescence spectrometer has a performance that is superior in many ways to those currently available. It consists of an array of 4 large area microcalorimeters with 95% quantum efficiency at 6 keV and it produces X-ray spectra between 0.2 keV and 7 keV with an energy resolution of 7 to 10 eV. The resolution is obtained at input count rates per array element of 10 to 50 Hz in real-time, with analog pulse processing and thermal pile-up rejection. This performance cannot be matched by currently available X-ray spectrometers. The detectors are incorporated into a compact and portable cryogenic refrigerator system that is ready for use in many analytical spectroscopy applications as a tool for X-ray microanalysis or in research applications such as laboratory and astrophysical X-ray and particle spectroscopy. 6 figs.

  6. Broadband high resolution X-ray spectral analyzer

    DOE Patents [OSTI]

    Silver, Eric H. (Berkeley, CA); Legros, Mark (Berkeley, CA); Madden, Norm W. (Livermore, CA); Goulding, Fred (Lafayette, CA); Landis, Don (Pinole, CA)

    1998-01-01T23:59:59.000Z

    A broad bandwidth high resolution x-ray fluorescence spectrometer has a performance that is superior in many ways to those currently available. It consists of an array of 4 large area microcalorimeters with 95% quantum efficiency at 6 keV and it produces x-ray spectra between 0.2 keV and 7 keV with an energy resolution of 7 to 10 eV. The resolution is obtained at input count rates per array element of 10 to 50 Hz in real-time, with analog pulse processing and thermal pile-up rejection. This performance cannot be matched by currently available x-ray spectrometers. The detectors are incorporated into a compact and portable cryogenic refrigerator system that is ready for use in many analytical spectroscopy applications as a tool for x-ray microanalysis or in research applications such as laboratory and astrophysical x-ray and particle spectroscopy.

  7. X-Ray Diffraction Microscopy of Magnetic Structures

    SciTech Connect (OSTI)

    Turner, J.; Lima, E.; Huang, X.; Krupin, O.; Seu, K.; Parks, D.; Kevan, S.; Kisslinger, K.; McNulty, I.; Gambino, R.; Mangin, S.; Roy, S. and Fischer, P.

    2011-07-14T23:59:59.000Z

    We report the first proof-of-principle experiment of iterative phase retrieval from magnetic x-ray diffraction. By using the resonant x-ray excitation process and coherent x-ray scattering, we show that linearly polarized soft x rays can be used to image both the amplitude and the phase of magnetic domain structures. We recovered the magnetic structure of an amorphous terbium-cobalt thin film with a spatial resolution of about 75 nm at the Co L{sub 3} edge at 778 eV. In comparison with soft x-ray microscopy images recorded with Fresnel zone plate optics at better than 25 nm spatial resolution, we find qualitative agreement in the observed magnetic structure.

  8. X-Ray Observations of Gamma-Ray Burst Afterglows

    E-Print Network [OSTI]

    Filippo Frontera

    2004-06-25T23:59:59.000Z

    The discovery by the BeppoSAX satellite of X-ray afterglow emission from the gamma-ray burst which occurred on 28 February 1997 produced a revolution in our knowledge of the gamma-ray burst phenomenon. Along with the discovery of X-ray afterglows, the optical afterglows of gamma-ray bursts were discovered and the distance issue was settled, at least for long $\\gamma$-ray bursts. The 30 year mystery of the gamma-ray burst phenomenon is now on the way to solution. Here I rewiew the observational status of the X-ray afterglow emission, its mean properties (detection rate, continuum spectra, line features, and light curves), and the X-ray constraints on theoretical models of gamma-ray bursters and their progenitors. I also discuss the early onset afterglow emission, the remaining questions, and the role of future X-ray afterglow observations.

  9. Scattering of x rays from low-Z materials

    SciTech Connect (OSTI)

    Gaines, J.L.; Kissel, L.D.; Catron, H.C.; Hansen, R.A.

    1980-08-01T23:59:59.000Z

    X rays incident on thin beryllium, boron, carbon, and other low-Z materials undergo both elastic and inelastic scattering as well as diffraction from the crystalline or crystalline-like structure of the material. Unpolarized monoenergetic x rays in the 1.5 to 8.0-keV energy range were used to determine the absolute scattering efficiency of thin beryllium, carbon, and boron foils. These measurements are compared to calculated scattering efficiencies predicted by single-atom theories. In addition, the relative scattering efficiency versus x-ray energy was measured for other low-Z foils using unpolarized bremsstrahlung x rays. In all the low-Z foils examined, we observed Bragg-like x-ray diffraction due to the ordered structure of the materials.

  10. Stored Luminescence Computed Tomography

    E-Print Network [OSTI]

    Cong, Wenxiang; Wang, Ge

    2013-01-01T23:59:59.000Z

    The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

  11. Deep x-ray lithography for micromechanics

    SciTech Connect (OSTI)

    Christenson, T.R. [Sandia National Labs., Albuquerque, NM (United States); Guckel, H. [Wisconsin Univ., Madison, WI (United States). Dept. of Electrical and Computer Engineering

    1995-08-01T23:59:59.000Z

    Extensions of the German LIGA process have brought about fabrication capability suitable for cost effective production of precision engineered components. The process attributes allow fabrication of mechanical components which are not capable of being made via conventional subtractive machining methods. Two process improvements have been responsible for this extended capability which involve the areas of thick photoresist application and planarization via precision lapping. Application of low-stress x-ray photoresist has been achieved using room temperature solvent bonding of a preformed photoresist sheet. Precision diamond lapping and polishing has provided a flexible process for the planarization of a wide variety of electroplated metals in the presence of photoresist. Exposure results from the 2.5 GeV National Synchrotron Light Source storage ring at Brookhaven National Laboratory have shown that structural heights of several millimeter and above are possible. The process capabilities are also well suited for microactuator fabrication. Linear and rotational magnetic microactuators have been constructed which use coil winding technology with LIGA fabricated coil forms. Actuator output forces of 1 milliNewton have been obtained with power dissipation on the order of milliWatts. A rotational microdynamometer system which is capable of measuring torque-speed data is also discussed.

  12. X-ray Emission from Massive StarsX-ray Emission from Massive Stars David CohenDavid Cohen

    E-Print Network [OSTI]

    Cohen, David

    X-ray Emission from Massive StarsX-ray Emission from Massive Stars David CohenDavid Cohen/s)Velocity (km/s) #12;absorption emission emission occulted emission emission UV telescope side side front back #12;absorption emission emission occulted emission emission UV telescope side side front back #12;The

  13. AugEX: AUGER ELECTRON AND X-RAY SPECTROMETER ON CHANDRAYAAN-2 ROVER

    E-Print Network [OSTI]

    Bapat, Bhas

    for determining elemental composition which have a space heritage X-Ray Fluorescence (XRF) Particle-induced X-ray fluorescence (XRF) Expected Advantage: cover low Z elements with higher sensitivity than XRF or PIXE. ACHARYA-ray absorption or charged particle bombardment X-ray emission induced by X-ray absorption: XRF X-ray emission

  14. Poly(iohexol) Nanoparticles As Contrast Agents for in Vivo Xray Computed Tomography Imaging

    E-Print Network [OSTI]

    Cheng, Jianjun

    Poly(iohexol) Nanoparticles As Contrast Agents for in Vivo Xray Computed Tomography Imaging Qian for in vivo X-ray computed tomography (CT) imaging. Compared to conventional small-molecule contrast agents with improved diagnosis accuracy over a broad time frame without multiple administrations. X-ray computed

  15. Soft-x-ray spectroscopy study of nanoscale materials

    SciTech Connect (OSTI)

    Guo, J.-H.

    2005-07-30T23:59:59.000Z

    The ability to control the particle size and morphology of nanoparticles is of crucial importance nowadays both from a fundamental and industrial point of view considering the tremendous amount of high-tech applications. Controlling the crystallographic structure and the arrangement of atoms along the surface of nanostructured material will determine most of its physical properties. In general, electronic structure ultimately determines the properties of matter. Soft X-ray spectroscopy has some basic features that are important to consider. X-ray is originating from an electronic transition between a localized core state and a valence state. As a core state is involved, elemental selectivity is obtained because the core levels of different elements are well separated in energy, meaning that the involvement of the inner level makes this probe localized to one specific atomic site around which the electronic structure is reflected as a partial density-of-states contribution. The participation of valence electrons gives the method chemical state sensitivity and further, the dipole nature of the transitions gives particular symmetry information. The new generation synchrotron radiation sources producing intensive tunable monochromatized soft X-ray beams have opened up new possibilities for soft X-ray spectroscopy. The introduction of selectively excited soft X-ray emission has opened a new field of study by disclosing many new possibilities of soft X-ray resonant inelastic scattering. In this paper, some recent findings regarding soft X-ray absorption and emission studies of various nanostructured systems are presented.

  16. Apparatus for generating x-ray holograms

    DOE Patents [OSTI]

    Rhodes, C.K.; Boyer, K.; Solem, J.C.; Haddad, W.S.

    1990-09-11T23:59:59.000Z

    Apparatus for x-ray microholography of living biological materials. A Fourier transform holographic configuration is described as being most suitable for the 3-dimensional recording of the physical characteristics of biological specimens. The use of a spherical scatterer as a reference and a charge-coupled device two-dimensional detector array placed in the forward direction relative to the incident x-radiation for viewing electromagnetic radiation simultaneously scattered from both the specimen and the reference scatterer permits the ready reconstruction of the details of the specimen from the fringe pattern detected by the charge-coupled device. For example, by using a nickel reference scatter at 4.5 nm, sufficient reference illumination is provided over a wide enough angle to allow similar resolution in both transverse and longitudinal directions. Both laser and synchrotron radiation sources are feasible for generating microholographs. Operation in the water window (2.4 to 4.5 nm) should provide maximum contrast for features of the specimen and spatial resolution on the order of the wavelength of x-radiation should be possible in all three dimensions, which is sufficient for the visualization of many biological features. It is anticipated that the present apparatus will find utility in other areas as well where microscopic physical details of a specimen are important. A computational procedure which enables the holographic data collected by the detector to be used to correct for misalignments introduced by inexact knowledge of the relative positions of the spherical reference scatterer and the sample under investigation has been developed. If the correction is performed prior to reconstruction, full compensation can be achieved and a faithfully reconstructed image produced. 7 figs.

  17. Apparatus for generating x-ray holograms

    DOE Patents [OSTI]

    Rhodes, Charles K. (Chicago, IL); Boyer, Keith (Los Alamos, NM); Solem, Johndale C. (Los Alamos, NM); Haddad, Waleed S. (Chicago, IL)

    1990-01-01T23:59:59.000Z

    Apparatus for x-ray microholography of living biological materials. A Fourier transform holographic configuration is described as being most suitable for the 3-dimensional recording of the physical characteristics of biological specimens. The use of a spherical scatterer as a reference and a charge-coupled device two-dimensional detector array placed in the forward direction relative to the incident x-radiation for viewing electromagnetic radiation simultaneously scattered from both the specimen and the reference scatterer permits the ready reconstruction of the details of the specimen from the fringe pattern detected by the charge-coupled device. For example, by using a nickel reference scatter at 4.5 nm, sufficient reference illumination is provided over a wide enough angle to allow similar resolution in both transverse and longitudinal directions. Both laser and synchrotron radiation sources are feasible for generating microholographs. Operation in the water window (2.4 to 4.5 nm) should provide maximum contrast for features of the specimen and spatial resolution on the order of the wavelength of x-radiation should be possible in all three dimensions, which is sufficient for the visualization of many biological features. It is anticipated that the present apparatus will find utility in other areas as well where microscopic physical details of a specimen are important. A computational procedure which enables the holographic data collected by the detector to be used to correct for misalignments introduced by inexact knowledge of the relative positions of the spherical reference scatterer and the sample under investigation has been developed. If the correction is performed prior to reconstruction, full compensation can be achieved and a faithfully reconstructed image produced.

  18. Wavelet-based local region-of-interest reconstruction for synchrotron radiation x-ray microtomography

    SciTech Connect (OSTI)

    Li Lingqi; Toda, Hiroyuki; Ohgaki, Tomomi; Kobayashi, Masakazu; Kobayashi, Toshiro; Uesugi, Kentaro; Suzuki, Yoshio [Department of Production Systems Engineering, Toyohashi University of Technology, Toyohashi, Aichi 441-8580 (Japan); Japan Synchrotron Radiation Research Institute, Sayo-gun, Hyougo 679-5198 (Japan)

    2007-12-01T23:59:59.000Z

    Synchrotron radiation x-ray microtomography is becoming a uniquely powerful method to nondestructively access three-dimensional internal microstructure in biological and engineering materials, with a resolution of 1 {mu}m or less. The tiny field of view of the detector, however, requires that the sample has to be strictly small, which would limit the practical applications of the method such as in situ experiments. In this paper, a wavelet-based local tomography algorithm is proposed to recover a small region of interest inside a large object only using the local projections, which is motivated by the localization property of wavelet transform. Local tomography experiment for an Al-Cu alloy is carried out at SPring-8, the third-generation synchrotron radiation facility in Japan. The proposed method readily enables the high-resolution observation for a large specimen, by which the applicability of the current microtomography would be promoted to a large extent.

  19. Three-dimensional assessment of low velocity impact damage in particle toughened composite laminates using micro-focus X-ray

    E-Print Network [OSTI]

    in carbon fibre reinforced polymer materials. Micro-focus X- ray computed tomography and synchrotron toughening particles in the resin of carbon fibre composites can lead to improved toughness in simpleThree-dimensional assessment of low velocity impact damage in particle toughened composite

  20. Spatiotemporal focusing dynamics in plasmas at X-ray wavelength

    SciTech Connect (OSTI)

    Sharma, A., E-mail: a-physics2001@yahoo.com; Tibai, Z. [Institute of Physics, University of Pecs, Pecs–7624 (Hungary)] [Institute of Physics, University of Pecs, Pecs–7624 (Hungary); Hebling, J. [Institute of Physics, University of Pecs, Pecs–7624 (Hungary) [Institute of Physics, University of Pecs, Pecs–7624 (Hungary); Szentagothai Research Centre, University of Pecs, Pecs-7624 (Hungary); Mishra, S. K. [Institute for Plasma Research, Gandhinagar (India)] [Institute for Plasma Research, Gandhinagar (India)

    2014-03-15T23:59:59.000Z

    Using a finite curvature beam, we investigate here the spatiotemporal focusing dynamics of a laser pulse in plasmas at X-ray wavelength. We trace the dependence of curvature parameter on the focusing of laser pulse and recognize that the self-focusing in plasma is more intense for the X-ray laser pulse with curved wavefront than with flat wavefront. The simulation results demonstrate that spatiotemporal focusing dynamics in plasmas can be controlled with the appropriate choice of beam-plasma parameters to explore the high intensity effects in X-ray regime.

  1. X-ray backscatter imaging of nuclear materials

    DOE Patents [OSTI]

    Chapman, Jeffrey Allen; Gunning, John E; Hollenbach, Daniel F; Ott, Larry J; Shedlock, Daniel

    2014-09-30T23:59:59.000Z

    The energy of an X-ray beam and critical depth are selected to detect structural discontinuities in a material having an atomic number Z of 57 or greater. The critical depth is selected by adjusting the geometry of a collimator that blocks backscattered radiation so that backscattered X-ray originating from a depth less than the critical depth is not detected. Structures of Lanthanides and Actinides, including nuclear fuel rod materials, can be inspected for structural discontinuities such as gaps, cracks, and chipping employing the backscattered X-ray.

  2. Gated x-ray detector for the National Ignition Facility

    SciTech Connect (OSTI)

    Oertel, John A.; Aragonez, Robert; Archuleta, Tom; Barnes, Cris; Casper, Larry; Fatherley, Valerie; Heinrichs, Todd; King, Robert; Landers, Doug; Lopez, Frank; Sanchez, Phillip; Sandoval, George; Schrank, Lou; Walsh, Peter; Bell, Perry; Brown, Matt; Costa, Robert; Holder, Joe; Montelongo, Sam; Pederson, Neal [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Lawrence Livermore National Laboratory, Livermore, California 94551-0808 (United States); VI Control Systems Ltd., Los Alamos, New Mexico 87544 (United States)

    2006-10-15T23:59:59.000Z

    Two new gated x-ray imaging cameras have recently been designed, constructed, and delivered to the National Ignition Facility in Livermore, CA. These gated x-Ray detectors are each designed to fit within an aluminum airbox with a large capacity cooling plane and are fitted with an array of environmental housekeeping sensors. These instruments are significantly different from earlier generations of gated x-ray images due, in part, to an innovative impedance matching scheme, advanced phosphor screens, pulsed phosphor circuits, precision assembly fixturing, unique system monitoring, and complete remote computer control. Preliminary characterization has shown repeatable uniformity between imaging strips, improved spatial resolution, and no detectable impedance reflections.

  3. X-ray afterglows from gamma-ray bursts

    E-Print Network [OSTI]

    M. Tavani

    1997-03-24T23:59:59.000Z

    We consider possible interpretations of the recently detected X- ray afterglow from the gamma-ray burst source GRB 970228. Cosmological and Galactic models of gamma-ray bursts predict different flux and spectral evolution of X-ray afterglows. We show that models based on adiabatic expansion of relativistic forward shocks require very efficient particle energization or post-burst re-acceleration during the expansion. Cooling neutron star models predict a very distinctive spectral and flux evolution that can be tested in current X-ray data.

  4. Linear accelerator x-ray sources with high duty cycle

    SciTech Connect (OSTI)

    Condron, Cathie; Brown, Craig; Gozani, Tsahi; Langeveld, Willem G. J. [Rapiscan Laboratories, Inc., 520 Almanor Ave. Sunnyvale, CA 94085 (United States); Hernandez, Michael [XScell corp., 2134 Old Middlefield Way, Mountain View, CA 94043 (United States)

    2013-04-19T23:59:59.000Z

    X-ray cargo inspection systems typically use a several-MV pulsed linear accelerator (linac) to produce a bremsstrahlung spectrum of x rays by bombarding a target with electrons. The x rays traverse the cargo and are detected by a detector array. Spectroscopy of the detected x rays is very desirable: if one can determine the spectrum of the transmitted x rays, one can determine the Z of the material they traversed. Even in relatively low-dose modes of operation, thousands of x rays arrive at each detector element during each pulse, unless the x rays are heavily absorbed or scattered by the cargo. For portal or fixed-site systems, dose rates, and therefore x-ray count rates, are even higher. Because of the high x-ray count rate, spectroscopy is impractical in conventional cargo inspection systems, except in certain special cases. For a mobile system, typical pulse durations are a few microseconds, and the number of pulses is on the order of 100 per second, leading to a duty factor of about 0.04%. Clearly, a linear accelerator x-ray source with much higher duty factor would be useful, since then the same number of x rays could be spread out over time, reducing the x-ray count rate. In this paper, we explore the possibility of designing a linear accelerator system, using more or less Conventional Off the Shelf (COTS) components, capable of duty cycles of 1% or greater. A survey was conducted of available linac RF source options and, given the possibilities, calculations were performed for suitable beam centerline designs. Keeping in mind that the size and cost of the accelerator system should be practical for use in a mobile cargo inspection system, only a few options are shown to be reasonably feasible, both requiring the use of klystrons instead of the magnetrons used in conventional systems. An S-Band design appears clearly possible, and there is also a promising X-Band design.

  5. Characterization of X-ray generator beam profiles.

    SciTech Connect (OSTI)

    Mitchell, Dean J; Harding, Lee T.; Thoreson, Gregory G.; Theisen, Lisa Anne; Parmeter, John Ethan; Thompson, Kyle Richard

    2013-07-01T23:59:59.000Z

    T to compute the radiography properties of various materials, the flux profiles of X-ray sources must be characterized. This report describes the characterization of X-ray beam profiles from a Kimtron industrial 450 kVp radiography system with a Comet MXC-45 HP/11 bipolar oil-cooled X-ray tube. The empirical method described here uses a detector response function to derive photon flux profiles based on data collected with a small cadmium telluride detector. The flux profiles are then reduced to a simple parametric form that enables computation of beam profiles for arbitrary accelerator energies.

  6. X-ray Diffraction from Membrane Protein Nanocrystals

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del SolStrengtheningWildfires may contribute more toConsensusX-RayX-RayX-ray

  7. Using Synchrotron X-Ray Nano-CT to Characterize SOFC Electrode Microstructures in Three-Dimensions at Operating Temperature

    SciTech Connect (OSTI)

    Shearing, P.R.; Bradley, R.S.; Gelb, J.; Lee, S.N.; Atkinson, A.; Withers, P.J.; Brandon, N.P. (Manchester); (Xradia); (ICL)

    2012-01-20T23:59:59.000Z

    In recent years, developments in tomography tools have provided unprecedented insight into the microstructure of electrodes for solid oxide fuel cells, enabling researchers to establish direct links between electrode microstructure and electrochemical performance. Here we present results of high resolution, synchrotron X-ray nano computed tomography experiments, which have enabled microstructural characterisation of a mixed ionic electronic conducting lanthanum strontium cobalt iron oxide (LSCF) cathode with sub-50nm resolution at operating temperature. Using the uniquely non-destructive nano-CT platform, it is possible to characterise microstructural evolution processes associated with heating and operation in-situ.

  8. Automated suppression of errors in LTP-II slope measurements with x-ray optics

    E-Print Network [OSTI]

    Ali, Zulfiqar

    2011-01-01T23:59:59.000Z

    slope measurements with x-ray optics Zulfiqar Ali, Curtis L.with state-of-the-art x-ray optics. Significant suppressionscanning, metrology of x-ray optics, deflectometry Abstract

  9. X-ray optics metrology limited by random noise, instrumental drifts, and systematic errors

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2010-01-01T23:59:59.000Z

    X-ray optics metrology limited by random noise, instrumentalUSA Center for X-ray Optics, Lawrence Berkeley Nationaland reflecting x-ray optics suitable for micro- and nano-

  10. Radiation exposure in X-ray-based imaging techniques used in osteoporosis

    E-Print Network [OSTI]

    Damilakis, John; Adams, Judith E.; Guglielmi, Giuseppe; Link, Thomas M.

    2010-01-01T23:59:59.000Z

    and nonradiologists in dual-energy X-ray absorptiometrymorphometry studies using dual-energy X-ray absorptiometry.dose measurements in dual energy X-ray absorptiometry (DXA).

  11. Beyond 3-D X-ray Imaging: Methodology Development and Applications...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to the availability of the new generation of X-ray sources and the advanced X-ray optics. The advanced X-ray Optics along with novel methodology has made it possible to...

  12. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and deposited as a liquid). The process results in devices, such as LED displays or solar cells, that are light, flexible, and inexpensive. The catch, however, is in the...

  13. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeedingBiomassPPPOPetroleum38 (1996)representative

  14. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for RenewableSpeedingBiomassPPPOPetroleum38 (1996)representativePolarized

  15. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)IntegratedSpeeding accessPeptoidLabPhysicsPits | NationalYou've heard it

  16. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)IntegratedSpeeding accessPeptoidLabPhysicsPits | NationalYou've heard itPolarized

  17. Polarized X-Rays Reveal Molecular Alignment in Printed Electronics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)IntegratedSpeeding accessPeptoidLabPhysicsPits | NationalYou've heard

  18. How Can X-ray Transient Absorption Spectroscopy Aide Solar Energy...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    are from optimized on structural, energetic and dynamic parameters. Intense X-ray pulses from synchrotrons and X-ray free electrons lasers coupled with ultrafast lasers...

  19. X-rays only when you want them: Report on Pseudo-single-bunch...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Speaker: David Robin, Lawrence Berkeley National Laboratory Program Description Laser pump - x-ray probe experiments require control over the x-ray pulse pattern and timing. Such...

  20. Scanning X-ray Microscopy Investigations into the Electron Beam Exposure Mechanism of Hydrogen Silsesquioxane Resists

    E-Print Network [OSTI]

    Olynick, Deirdre L.; Tivanski, Alexei V.; Gilles, Mary K.; Tyliszczak, Tolek; Salmassi, Farhad; Liddle, J. Alexander

    2006-01-01T23:59:59.000Z

    Scanning X-ray Microscopy Investigations into the Electronchemistry is investigated by Scanning Transmission X-raythe area exposed. 15 Recently, scanning transmission x-ray

  1. Soft X-Ray Microscopy and Spectroscopy at the Molecular Environmental...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Soft X-Ray Microscopy and Spectroscopy at the Molecular Environmental Science Beamline at the Advanced Light Source. Soft X-Ray Microscopy and Spectroscopy at the Molecular...

  2. X-Ray Fluorescence (XRF) Analysis of Obsidian Artifacts from Shoofly Ruin, Central Arizona

    E-Print Network [OSTI]

    Shackley, M. Steven

    1986-01-01T23:59:59.000Z

    X-RAY FLUORESCENCE (XRF) ANALYSIS OF OBSIDIAN ARTIFACTS FROM62:426-437. SOUTHWEST XRF PAPER Table 1. X-ray fluorescence

  3. In situ X-ray Characterization of Energy Storage Materials |...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    X-ray Characterization of Energy Storage Materials Tuesday, July 9, 2013 - 11:00am SLAC, Conference Room 137-322 Presented by Johanna Nelson, Stanford Postdoctoral Scholar, SSRL...

  4. Streaked x-ray microscopy of laser-fusion targets

    SciTech Connect (OSTI)

    Price, R.H.; Campbell, E.M.; Rosen, M.D.; Auerbach, J.M.; Phillion, D.W.; Whitlock, R.R.; Obenshain, S.P.; McLean, E.A.; Ripin, B.H.

    1982-08-01T23:59:59.000Z

    An ultrafast soft x-ray streak camera has been coupled to a Wolter axisymmetric x-ray microscope. This system was used to observe the dynamics of laser fusion targets both in self emission and backlit by laser produced x-ray sources. Spatial resolution was 7 ..mu..m and temporal resolution was 20 ps. Data is presented showing the ablative acceleration of foils to velocities near 10/sup 7/ cm/sec and the collision of an accelerated foil with a second foil, observed using 3 keV streaked x-ray backlighting. Good agreement was found between hydrocode simulations, simple models of the ablative acceleration and the observed velocities of the carbon foils.

  5. Resonant Soft X-Ray Scattering - Combining Structural with Spectroscop...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    as well as important L-edges of the 3d transition metals important in magnetic and oxide systems. Measurements of soft x-ray absorption spectra are inherently surface sensitive,...

  6. Staff at sector 30, inelastic x-ray scattering

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Sector 30 Staff Advanced Photon Source A U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences national synchrotron x-ray research facility Search Button...

  7. Imaging Quantum States with X-ray Compton Scattering | Stanford...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Imaging Quantum States with X-ray Compton Scattering Wednesday, April 8, 2015 - 3:00pm SLAC, Redtail Hawk Conference Room 108A Speaker: Yoshiharu Sakurai (Japan Synchrotron...

  8. The Identification Problem for the attenuated X-ray transform

    E-Print Network [OSTI]

    2013-11-16T23:59:59.000Z

    X-ray transform has been solved in [27], see also [15]. The main result in .... For any compact set K ? T2, we define Hs(K) to be the closed subspace of Hs(T2) of

  9. Systems and methods for detecting x-rays

    DOE Patents [OSTI]

    Bross, Alan D.; Mellott, Kerry L.; Pla-Dalmau, Anna

    2006-05-02T23:59:59.000Z

    Systems and methods for detecting x-rays are disclosed herein. One or more x-ray-sensitive scintillators can be configured from a plurality of heavy element nano-sized particles and a plastic material, such as polystyrene. As will be explained in greater detail herein, the heavy element nano-sized particles (e.g., PbWO4) can be compounded into the plastic material with at least one dopant that permits the plastic material to scintillate. X-rays interact with the heavy element nano-sized particles to produce electrons that can deposit energy in the x-ray sensitive scintillator, which in turn can produce light.

  10. Epoxy replication for Wolter x-ray microscope fabrication

    SciTech Connect (OSTI)

    Priedhorsky, W.

    1981-01-01T23:59:59.000Z

    An epoxy replica of a test piece designed to simulate a Wolter x-ray microscope geometry showed no loss of x-ray reflectivity or resolution, compared to the original. The test piece was a diamond-turned cone with 1.5/sup 0/ half angle. A flat was fly-cut on one side, then super- and conventionally polished. The replica was separated at the 1.5/sup 0/-draft angle, simulating a shallow angle Wolter microscope geometry. A test with 8.34 A x rays at 0.9/sup 0/ grazing angle showed a reflectivity of 67% for the replica flat surface, and 70% for the original. No spread of the reflected beam was observed with a 20-arc second wide test beam. This test verifies the epoxy replication technique for production of Wolter x-ray microscopes.

  11. X-ray ptychography, fluorescence microscopy combo sheds new light...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    advance required the high brightness of the APS as an X-ray source and points the way to advances that can be expected as it is planned to be increased a hundredfold in the...

  12. Vitreous carbon mask substrate for X-ray lithography

    DOE Patents [OSTI]

    Aigeldinger, Georg (Livermore, CA); Skala, Dawn M. (Fremont, CA); Griffiths, Stewart K. (Livermore, CA); Talin, Albert Alec (Livermore, CA); Losey, Matthew W. (Livermore, CA); Yang, Chu-Yeu Peter (Dublin, CA)

    2009-10-27T23:59:59.000Z

    The present invention is directed to the use of vitreous carbon as a substrate material for providing masks for X-ray lithography. The new substrate also enables a small thickness of the mask absorber used to pattern the resist, and this enables improved mask accuracy. An alternative embodiment comprised the use of vitreous carbon as a LIGA substrate wherein the VC wafer blank is etched in a reactive ion plasma after which an X-ray resist is bonded. This surface treatment provides a surface enabling good adhesion of the X-ray photoresist and subsequent nucleation and adhesion of the electrodeposited metal for LIGA mold-making while the VC substrate practically eliminates secondary radiation effects that lead to delamination of the X-ray resist form the substrate, the loss of isolated resist features, and the formation of a resist layer adjacent to the substrate that is insoluble in the developer.

  13. Performance enhancement approaches for a dual energy x-ray

    E-Print Network [OSTI]

    Fu, Kenneth

    2010-01-01T23:59:59.000Z

    Evans, J.P.O. , “Stereoscopic dual energy imaging for targetCrawford, C.R. , “Dual Energy Volumetric X-ray Tomographicimages in 4–10 MeV Dual- energy customs system for material

  14. X-Ray Diffraction Microscopy of Magnetic Structures

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    12.0.2.2 Citation: J.J. Turner et al., "X-Ray Diffraction Microscopy of Magnetic Structures," Phys. Rev. Lett. 107, 033904 (2011). Web: http:prl.aps.orgpdfPRLv107i3e033904...

  15. Magnetism studies using resonant, coherent, x-ray scattering...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Magnetism studies using resonant, coherent, x-ray scattering Monday, September 10, 2012 - 10:00am SLAC, Bldg. 137, Room 226 Keoki Seu Seminar: With the advent of free electron...

  16. Towards attosecond X-ray pulses from the FEL

    E-Print Network [OSTI]

    Zholents, Alexander A.; Fawley, William M.

    2004-01-01T23:59:59.000Z

    can be used instead of HC FEL. In the following illustra-UM is now tuned for resonant FEL interaction with the 32-nmAttosecond X-Ray Pulses from the FEL Alexander A. Zholents,

  17. X-ray mask and method for making

    DOE Patents [OSTI]

    Morales, Alfredo M.

    2004-10-26T23:59:59.000Z

    The present invention describes a method for fabricating an x-ray mask tool which is a contact lithographic mask which can provide an x-ray exposure dose which is adjustable from point-to-point. The tool is useful in the preparation of LIGA plating molds made from PMMA, or similar materials. In particular the tool is useful for providing an ability to apply a graded, or "stepped" x-ray exposure dose across a photosensitive substrate. By controlling the x-ray radiation dose from point-to-point, it is possible to control the development process for removing exposed portions of the substrate; adjusting it such that each of these portions develops at a more or less uniformly rate regardless of feature size or feature density distribution.

  18. High performance x-ray anti-scatter grid

    DOE Patents [OSTI]

    Logan, C.M.

    1995-05-23T23:59:59.000Z

    Disclosed are an x-ray anti-scatter grid for x-ray imaging, particularly for screening mammography, and method for fabricating same, x-rays incident along a direct path pass through a grid composed of a plurality of parallel or crossed openings, microchannels, grooves, or slots etched in a substrate, such as silicon, having the walls of the microchannels or slots coated with a high opacity material, such as gold, while x-rays incident at angels with respect to the slots of the grid, arising from scatter, are blocked. The thickness of the substrate is dependent on the specific application of the grid, whereby a substrate of the grid for mammography would be thinner than one for chest radiology. Instead of coating the walls of the slots, such could be filed with an appropriate liquid, such as mercury. 4 Figs.

  19. High performance x-ray anti-scatter grid

    DOE Patents [OSTI]

    Logan, Clinton M. (Pleasanton, CA)

    1995-01-01T23:59:59.000Z

    An x-ray anti-scatter grid for x-ray imaging, particularly for screening mammography, and method for fabricating same, x-rays incident along a direct path pass through a grid composed of a plurality of parallel or crossed openings, microchannels, grooves, or slots etched in a substrate, such as silicon, having the walls of the microchannels or slots coated with a high opacity material, such as gold, while x-rays incident at angels with respect to the slots of the grid, arising from scatter, are blocked. The thickness of the substrate is dependent on the specific application of the grid, whereby a substrate of the grid for mammography would be thinner than one for chest radiology. Instead of coating the walls of the slots, such could be filed with an appropriate liquid, such as mercury.

  20. Recent Flash X-Ray Injector Modeling

    SciTech Connect (OSTI)

    Houck, T; Blackfield, D; Burke, J; Chen, Y; Javedani, J; Paul, A C

    2004-11-10T23:59:59.000Z

    The injector of the Flash X-Ray (FXR) accelerator has a significantly larger than expected beam emittance. A computer modeling effort involving three different injector design codes was undertaken to characterize the FXR injector and determine the cause of the large emittance. There were some variations between the codes, but in general the simulations were consistent and pointed towards a much smaller normalized, rms emittance (36 cm-mr) than what was measured (193 cm-mr) at the exit of the injector using a pepperpot technique. The simulations also indicated that the present diode design was robust with respect to perturbations to the nominal design. Easily detected mechanical alignment/position errors and magnet errors did not lead to appreciable increase in the simulated emittance. The physics of electron emission was not modeled by any of the codes and could be the source of increased emittance. The nominal simulation assumed uniform Child-Langmuir Law emission from the velvet cathode and no shroud emission. Simulations that looked at extreme non-uniform cathode and shroud emission scenarios resulted in doubling of the emittance. An alternative approach was to question the pepperpot measurement. Simulations of the measurement showed that the pepperpot aperture foil could double the emittance with respect to the non-disturbed beam. This leads to a diplomatic explanation of the discrepancy between predicted and measured emittance where the fault is shared. The measured value is too high due to the effect of the diagnostic on the beam and the simulations are too low because of unaccounted cathode and/or shroud emission physics. Fortunately there is a relatively simple experiment that can resolve the emittance discrepancy. If the large measured emittance value is correct, the beam envelope is emittance dominated at modest values of focusing field and beam radius. Measurements of the beam envelope on an imaging foil at the exit of the injector would lead to an accurate value of the emittance. If the emittance was approximately half of the measured value, the beam envelope is slightly space charge dominated, but envelope measurements would set reasonable bounds on the emittance value. For an emittance much less than 100 cm-mr, the envelope measurements would be insensitive to emittance. The outcome of this envelope experiment determines if a redesigned diode is needed or if more sophisticated emittance measurements should be pursued.

  1. X-ray tube with magnetic electron steering

    DOE Patents [OSTI]

    Reed, Kim W. (Albuquerque, NM); Turman, Bobby N. (Albuquerque, NM); Kaye, Ronald J. (Albuquerque, NM); Schneider, Larry X. (Albuquerque, NM)

    2000-01-01T23:59:59.000Z

    An X-ray tube uses a magnetic field to steer electrons. The magnetic field urges electrons toward the anode, increasing the proportion of electrons emitted from the cathode that reach desired portions of the anode and consequently contribute to X-ray production. The magnetic field also urges electrons reflected from the anode back to the anode, further increasing the efficiency of the tube.

  2. Quantum coherence phenomena in x-ray optics

    E-Print Network [OSTI]

    Anisimov, Petr Mikhailovich

    2009-05-15T23:59:59.000Z

    QUANTUM COHERENCE PHENOMENA IN X-RAY OPTICS A Dissertation by PETR MIKHAILOVICH ANISIMOV Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY December... 2008 Major Subject: Physics QUANTUM COHERENCE PHENOMENA IN X-RAY OPTICS A Dissertation by PETR MIKHAILOVICH ANISIMOV Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of DOCTOR...

  3. New Directions in X-Ray Light Sources

    ScienceCinema (OSTI)

    Roger Falcone

    2010-01-08T23:59:59.000Z

    July 15, 2008 Berkeley Lab lecture: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.

  4. Enhanced betatron X-rays from axially modulated plasma wakefields

    E-Print Network [OSTI]

    Palastro, J P; Gordon, D

    2015-01-01T23:59:59.000Z

    In the cavitation regime of plasma-based accelerators, a population of high-energy electrons tailing the driver can undergo betatron motion. The motion results in X-ray emission, but the brilliance and photon energy are limited by the electrons' initial transverse coordinate. To overcome this, we exploit parametrically unstable betatron motion in a cavitated, axially modulated plasma. Theory and simulations are presented showing that the unstable oscillations increase both the total X-ray energy and average photon energy.

  5. A short working distance multiple crystal x-ray spectrometer

    SciTech Connect (OSTI)

    Dickinson, B.; Seidler, G. T.; Webb, Z. W.; Bradley, J. A.; Nagle, K. P. [Department of Physics, University of Washington, Seattle, Washington 98195 (United States); Heald, S. M. [Advanced Photon Source, Argonne National Laboratories, Argonne, Illinois 60439 (United States); Gordon, R. A. [Department of Physics, Simon Fraser University, Burnaby, British Columbia V5A 1S6 (Canada); Chou, I. M. [U.S. Geological Survey, Reston, Virginia 20192 (United States)

    2008-12-15T23:59:59.000Z

    For x-ray spot sizes of a few tens of microns or smaller, a millimeter-sized flat analyzer crystal placed {approx}1 cm from the sample will exhibit high energy resolution while subtending a collection solid angle comparable to that of a typical spherically bent crystal analyzer (SBCA) at much larger working distances. Based on this observation and a nonfocusing geometry for the analyzer optic, we have constructed and tested a short working distance (SWD) multicrystal x-ray spectrometer. This prototype instrument has a maximum effective collection solid angle of 0.14 sr, comparable to that of 17 SBCA at 1 m working distance. We find good agreement with prior work for measurements of the Mn K{beta} x-ray emission and resonant inelastic x-ray scattering for MnO, and also for measurements of the x-ray absorption near-edge structure for Dy metal using L{alpha}{sub 2} partial-fluorescence yield detection. We discuss future applications at third- and fourth-generation light sources. For concentrated samples, the extremely large collection angle of SWD spectrometers will permit collection of high-resolution x-ray emission spectra with a single pulse of the Linac Coherent Light Source. The range of applications of SWD spectrometers and traditional multi-SBCA instruments has some overlap, but also is significantly complementary.

  6. Quiet Sun X-rays as Signature for New Particles

    E-Print Network [OSTI]

    K. Zioutas; K. Dennerl; L. DiLella; D. H. H. Hoffmann; J. Jacoby; Th. Papaevangelou

    2004-03-08T23:59:59.000Z

    We have studied published data from the Yohkoh solar X-ray mission, with the purpose of searching for signals from radiative decays of new, as yet undiscovered massive neutral particles. This search is based on the prediction that solar axions of the Kaluza-Klein type should result in the emission of X-rays from the Sun direction beyond the limb with a characteristic radial distribution. These X-rays should be observed more easily during periods of quiet Sun. An additional signature is the observed emission of hard X-rays by SMM, NEAR and RHESSI. The recent observation made by RHESSI of a continuous emission from the non-flaring Sun of X-rays in the 3 to ~15 keV range fits the generic axion scenario. This work also suggests new analyses of existing data, in order to exclude instrumental effects; it provides the rationale for targeted observations with present and upcoming (solar) X-ray telescopes, which can provide the final answer on the nature of the signals considered here. Such measurements become more promising during the forthcoming solar cycle minimum with an increased number of quiet Sun periods.

  7. X-ray absorption in distant type II QSOs

    E-Print Network [OSTI]

    Krumpe, M; Corral, A; Schwope, A D; Carrera, F J; Barcons, X; Page, M; Mateos, S; Tedds, J A; Watson, M G

    2008-01-01T23:59:59.000Z

    We present the results of the X-ray spectral analysis of an XMM-Newton-selected type II QSO sample with z>0.5 and 0.5-10 keV flux of 0.3-33 x 10^{-14} erg/s/cm^2. The distribution of absorbing column densities in type II QSOs is investigated and the dependence of absorption on X-ray luminosity and redshift is studied. We inspected 51 spectroscopically classified type II QSO candidates from the XMM-Newton Marano field survey, the XMM-Newton-2dF wide angle survey (XWAS), and the AXIS survey to set-up a well-defined sample with secure optical type II identifications. Fourteen type II QSOs were classified and an X-ray spectral analysis performed. Since most of our sources have only ~40 X-ray counts (PN-detector), we carefully studied the fit results of the simulated X-ray spectra as a function of fit statistic and binning method. We determined that fitting the spectra with the Cash-statistic and a binning of minimum one count per bin recovers the input values of the simulated X-ray spectra best. Above 100 PN coun...

  8. Spectral Formation in X-Ray Pulsar Accretion Columns

    E-Print Network [OSTI]

    Peter A. Becker; Michael T. Wolff

    2005-03-03T23:59:59.000Z

    We present the first self-consistent model for the dynamics and the radiative transfer occurring in bright X-ray pulsar accretion columns, with a special focus on the role of the shock in energizing the emerging X-rays. The pressure inside the accretion column of a luminous X-ray pulsar is dominated by the photons, and consequently the equations describing the coupled radiative-dynamical structure must be solved simultaneously. Spectral formation in these sources is therefore a complex, nonlinear phenomenon. We obtain the analytical solution for the Green's function describing the upscattering of monochromatic radiation injected into the column from the thermal mound located near the base of the flow. The Green's function is convolved with a Planck distribution to model the X-ray spectrum resulting from the reprocessing of blackbody photons produced in the thermal mound. These photons diffuse through the infalling gas and eventually escape out the walls of the column, forming the observed X-ray spectrum. We show that the resulting column-integrated, phase-averaged spectrum has a power-law shape at high energies and a blackbody shape at low energies, in agreement with the observational data for many X-ray pulsars.

  9. Proton Computed Tomography and Constructing Tracker Boards Gatlin Bredeson

    E-Print Network [OSTI]

    Belanger, David P.

    1 ABSTRACT Proton Computed Tomography and Constructing Tracker Boards By Gatlin Bredeson Scientists tomography (xCT) with proton computed tomography (pCT). During a CT scan, protons pass through a phantom University to build tracker boards to assist in creating a system that seeks to replace X-ray computed

  10. 54X-rays from Hot Gases Near the SN1979C Black Hole The Chandra X-Ray Observatory

    E-Print Network [OSTI]

    is in solar mass units, and R is in kilometers. Problem 1 - Combining these equations using the method-Newton and the German ROSAT observatory revealed a bright source of X-rays that has remained steady for the 12 years, or distribution of X-rays with energy, support the idea that the object in SN 1979C is a black hole being fed

  11. X-ray absorption in distant type II QSOs

    E-Print Network [OSTI]

    M. Krumpe; G. Lamer; A. Corral; A. D. Schwope; F. J. Carrera; X. Barcons; M. Page; S. Mateos; J. A. Tedds; M. G. Watson

    2008-03-10T23:59:59.000Z

    We present the results of the X-ray spectral analysis of an XMM-Newton-selected type II QSO sample with z>0.5 and 0.5-10 keV flux of 0.3-33 x 10^{-14} erg/s/cm^2. The distribution of absorbing column densities in type II QSOs is investigated and the dependence of absorption on X-ray luminosity and redshift is studied. We inspected 51 spectroscopically classified type II QSO candidates from the XMM-Newton Marano field survey, the XMM-Newton-2dF wide angle survey (XWAS), and the AXIS survey to set-up a well-defined sample with secure optical type II identifications. Fourteen type II QSOs were classified and an X-ray spectral analysis performed. Since most of our sources have only ~40 X-ray counts (PN-detector), we carefully studied the fit results of the simulated X-ray spectra as a function of fit statistic and binning method. We determined that fitting the spectra with the Cash-statistic and a binning of minimum one count per bin recovers the input values of the simulated X-ray spectra best. Above 100 PN counts, the free fits of the spectrum's slope and absorbing hydrogen column density are reliable. We find only moderate absorption (N_H=(2-10) x 10^22 cm^-2) and no obvious trends with redshift and intrinsic X-ray luminosity. In a few cases a Compton-thick absorber cannot be excluded. Two type II objects with no X-ray absorption were discovered. We find no evidence for an intrinsic separation between type II AGN and high X-ray luminosity type II QSO in terms of absorption. The stacked X-ray spectrum of our 14 type II QSOs shows no iron K-alpha line. In contrast, the stack of the 8 type II AGN reveals a very prominent iron K-alpha line at an energy of ~ 6.6 keV and an EW ~ 2 keV.

  12. A High Efficiency Grazing Incidence Pumped X-ray Laser

    SciTech Connect (OSTI)

    Dunn, J; Keenan, R; Price, D F; Patel, P K; Smith, R F; Shlyaptsev, V N

    2006-08-31T23:59:59.000Z

    The main objective of the project is to demonstrate a proof-of-principle, new type of high efficiency, short wavelength x-ray laser source that will operate at unprecedented high repetition rates (10Hz) that could be scaled to 1kHz or higher. The development of a high average power, tabletop x-ray laser would serve to complement the wavelength range of 3rd and future 4th generation light sources, e.g. the LCLS, being developed by DOE-Basic Energy Sciences. The latter are large, expensive, central, synchrotron-based facilities while the tabletop x-ray laser is compact, high-power laser-driven, and relatively inexpensive. The demonstration of such a unique, ultra-fast source would allow us to attract funding from DOE-BES, NSF and other agencies to pursue probing of diverse materials undergoing ultrafast changes. Secondly, this capability would have a profound impact on the semiconductor industry since a coherent x-ray laser source would be ideal for ''at wavelength'' {approx}13 nm metrology and microscopy of optics and masks used in EUV lithography. The project has major technical challenges. We will perform grazing-incidence pumped laser-plasma experiments in flat or groove targets which are required to improve the pumping efficiency by ten times. Plasma density characterization using our existing unique picosecond x-ray laser interferometry of laser-irradiated targets is necessary. Simulations of optical laser propagation as well as x-ray laser production and propagation through freely expanding and confined plasma geometries are essential. The research would be conducted using the Physics Directorate Callisto and COMET high power lasers. At the end of the project, we expect to have a high-efficiency x-ray laser scheme operating below 20 nm at 10Hz with a pulse duration of {approx}2 ps. This will represent the state-of-the-art in x-ray lasers and would be a major step forward from our present picosecond laser-driven x-ray lasers. There is an added bonus of creating the shortest wavelength laboratory x-ray laser, below 4.5 nm and operating in the water window, by using the high-energy capability of the Titan laser.

  13. HIgh Rate X-ray Fluorescence Detector

    SciTech Connect (OSTI)

    Grudberg, Peter Matthew [XIA LLC

    2013-04-30T23:59:59.000Z

    The purpose of this project was to develop a compact, modular multi-channel x-ray detector with integrated electronics. This detector, based upon emerging silicon drift detector (SDD) technology, will be capable of high data rate operation superior to the current state of the art offered by high purity germanium (HPGe) detectors, without the need for liquid nitrogen. In addition, by integrating the processing electronics inside the detector housing, the detector performance will be much less affected by the typically noisy electrical environment of a synchrotron hutch, and will also be much more compact than current systems, which can include a detector involving a large LN2 dewar and multiple racks of electronics. The combined detector/processor system is designed to match or exceed the performance and features of currently available detector systems, at a lower cost and with more ease of use due to the small size of the detector. In addition, the detector system is designed to be modular, so a small system might just have one detector module, while a larger system can have many â?? you can start with one detector module, and add more as needs grow and budget allows. The modular nature also serves to simplify repair. In large part, we were successful in achieving our goals. We did develop a very high performance, large area multi-channel SDD detector, packaged with all associated electronics, which is easy to use and requires minimal external support (a simple power supply module and a closed-loop water cooling system). However, we did fall short of some of our stated goals. We had intended to base the detector on modular, large-area detectors from Ketek GmbH in Munich, Germany; however, these were not available in a suitable time frame for this project, so we worked instead with pnDetector GmbH (also located in Munich). They were able to provide a front-end detector module with six 100 m^2 SDD detectors (two monolithic arrays of three elements each) along with associated preamplifiers; these detectors surpassed the performance we expected to get from the Ketek detectors, however they are housed in a sealed module, which does not offer the ease of repair and expandability weâ??d hoped to achieve with the Ketek SDDâ??s. Our packaging efforts were quite successful, as we came up with a very compact way to mount the detector and to house the associated electronics, as well as a very effective way to reliably take out the heat (from the electronics as well as the detectorâ??s Peltier coolers) without risk of condensation and without external airflow or vibration, which could create problems for the target applications. While we were able to design compact processing electronics that fit into the detector assembly, they are still at the prototype stage, and would require a significant redesign to achieve product status. We have not yet tested this detector at a synchrotron facility; we do still plan on working with some close contacts at the nearby Stanford Synchrotron Radiation Laboratory (SSRL) to get some testing with the beam (using existing commercial electronics for readout, as the integrated processor is not ready for use).

  14. Gain dynamics in a soft X-ray laser ampli er perturbed by a strong injected X-ray eld

    SciTech Connect (OSTI)

    Wang, Yong [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Wang, Shoujun [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Oliva, E [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Lu, L [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Berrill, Mark A [ORNL] [ORNL; Yin, Liang [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Nejdl, J [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Luther, Brad [Colorado State University, Fort Collins] [Colorado State University, Fort Collins; Proux, C [Laboratoire d’Optique Applique´e, ENSTA, CNRS, Ecole Polytechnique] [Laboratoire d’Optique Applique´e, ENSTA, CNRS, Ecole Polytechnique; Le, T. T. [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Dunn, James [Lawrence Livermore National Laboratory (LLNL)] [Lawrence Livermore National Laboratory (LLNL); Ros, D [Laboratoire de Physique des Gaz et des Gaz et des Plasmas] [Laboratoire de Physique des Gaz et des Gaz et des Plasmas; Zeitoun, Philippe [École Polytechnique] [École Polytechnique; Rocca, Jorge [Colorado State University, Fort Collins] [Colorado State University, Fort Collins

    2014-01-01T23:59:59.000Z

    Seeding soft X-ray plasma ampli ers with high harmonics has been demonstrated to generate high-brightness soft X-ray laser pulses with full spatial and temporal coherence. The interaction between the injected coherent eld and the swept-gain medium has been modelled. However, no exper- iment has been conducted to probe the gain dynamics when perturbed by a strong external seed eld. Here, we report the rst X-ray pump X-ray probe measurement of the nonlinear response of a plasma ampli er perturbed by a strong soft X-ray ultra-short pulse. We injected a sequence of two time-delayed high-harmonic pulses (l518.9 nm) into a collisionally excited nickel-like molybdenum plasma to measure with femto-second resolution the gain depletion induced by the saturated ampli cation of the high-harmonic pump and its subsequent recovery. The measured fast gain recovery in 1.5 1.75 ps con rms the possibility to generate ultra-intense, fully phase-coherent soft X-ray lasers by chirped pulse ampli cation in plasma ampli ers.

  15. Water destruction by X-rays in young stellar objects

    E-Print Network [OSTI]

    P. Stauber; J. K. Jorgensen; E. F. van Dishoeck; S. D. Doty; A. O. Benz

    2006-02-06T23:59:59.000Z

    We study the H2O chemistry in star-forming environments under the influence of a central X-ray source and a central far ultraviolet (FUV) radiation field. The gas-phase water chemistry is modeled as a function of time, hydrogen density and X-ray flux. To cover a wide range of physical environments, densities between n_H = 10^4-10^9 cm^-3 and temperatures between T = 10-1000 K are studied. Three different regimes are found: For T water abundance is of order 10^-7-10^-6 and can be somewhat enhanced or reduced due to X-rays, depending on time and density. For 100 K 10^-3 ergs s-1 cm^-2 (t = 10^4 yrs) and for F_X > 10^-4 ergs s^-1 cm^-2 (t = 10^5 yrs). At higher temperatures (T > 250 K) and hydrogen densities, water can persist with x(H2O) ~ 10^-4 even for high X-ray fluxes. The X-ray and FUV models are applied to envelopes around low-mass Class 0 and I young stellar objects (YSOs). Water is destroyed in both Class 0 and I envelopes on relatively short timescales (t ~ 5000 yrs) for realistic X-ray fluxes, although the effect is less prominent in Class 0 envelopes due to the higher X-ray absorbing densities there. FUV photons from the central source are not effective in destroying water. The average water abundance in Class I sources for L_X > 10^27 ergs s^-1 is predicted to be x(H2O) < 10^-6.

  16. Chandra Multiwavelength Project X-ray Point Source Catalog

    E-Print Network [OSTI]

    Minsun Kim; Dong-Woo Kim; Belinda J. Wilkes; Paul J. Green; Eunhyeuk Kim; Craig S. Anderson; Wayne A. Barkhouse; Nancy R. Evans; Zeljko Ivezic; Margarita Karovska; Vinay L. Kashyap; Myung Gyoon Lee; Peter Maksym; Amy E. Mossman; John D. Silverman; Harvey D. Tananbaum

    2006-11-28T23:59:59.000Z

    We present the Chandra Multiwavelength Project (ChaMP) X-ray point source catalog with ~6,800 X-ray sources detected in 149 Chandra observations covering \\~10 deg^2. The full ChaMP catalog sample is seven times larger than the initial published ChaMP catalog. The exposure time of the fields in our sample ranges from 0.9 to 124 ksec, corresponding to a deepest X-ray flux limit of f_{0.5-8.0} = 9 x 10^{-16} erg/cm2/sec. The ChaMP X-ray data have been uniformly reduced and analyzed with ChaMP-specific pipelines, and then carefully validated by visual inspection. The ChaMP catalog includes X-ray photometric data in 8 different energy bands as well as X-ray spectral hardness ratios and colors. To best utilize the ChaMP catalog, we also present the source reliability, detection probability and positional uncertainty. To quantitatively assess those parameters, we performed extensive simulations. In particular, we present a set of empirical equations: the flux limit as a function of effective exposure time, and the positional uncertainty as a function of source counts and off axis angle. The false source detection rate is ~1% of all detected ChaMP sources, while the detection probability is better than ~95% for sources with counts >30 and off axis angle <5 arcmin. The typical positional offset between ChaMP X-ray source and their SDSS optical counterparts is 0.7+-0.4 arcsec, derived from ~900 matched sources.

  17. Regularized Equally Sloped Tomography Algorithm for Low Dose X-Ray Computed Tomography

    E-Print Network [OSTI]

    Zhao, Yunzhe

    2012-01-01T23:59:59.000Z

    of the central slice of Siemens SOMATOM sensation 64 CT3.6. The three inserts from Siemens’ image quality phantom,3.6. The three inserts from Siemens’ image quality EMMA

  18. Regularized Equally Sloped Tomography Algorithm for Low Dose X-Ray Computed Tomography

    E-Print Network [OSTI]

    Zhao, Yunzhe

    2012-01-01T23:59:59.000Z

    without the conjugate gradient method used to calculateimplemented through a conjugate gradient method and can beimplemented through a conjugate gradient method and can be

  19. Tools for a Theoretical X-ray Beamline J. J. Rehr*

    E-Print Network [OSTI]

    Botti, Silvana

    Tools for a Theoretical X-ray Beamline J. J. Rehr* Department of Physics University of Washington, France 22 October 2010 #12;X-ray Spectroscopy Beamline #12;Tools for a Theoretical X-ray Beamline · GOAL Theoretical X-ray Beamline: 2. Tools for EXAFS and XANES, EELS, XMCD, ... 3. DFT/MD-TOOLS 4. Next generation

  20. Fourier analysis of X-ray micro-diffraction profiles to characterize laser shock peened metals

    E-Print Network [OSTI]

    Yao, Y. Lawrence

    .L., 1950. The effect of cold-work distortion on X-ray pat- terns. Journal of Applied Physics 21, 595LSP need to be further studied from the measured X-ray micro-diffraction profile. Broadening of X-rayFourier analysis of X-ray micro-diffraction profiles to characterize laser shock peened metals

  1. Quantification of rapid environmental redox processes with quick-scanning x-ray absorption

    E-Print Network [OSTI]

    Sparks, Donald L.

    Quantification of rapid environmental redox processes with quick-scanning x-ray absorption. Here we apply quick-scanning x-ray absorption spectroscopy (Q-XAS), at sub-second time that can be measured using x-ray absorption spectroscopy. arsenic extended x-ray absorption fine structure

  2. Method and apparatus for micromachining using hard X-rays

    DOE Patents [OSTI]

    Siddons, David Peter (Shoreham, NY); Johnson, Erik D. (Ridge, NY); Guckel, Henry (Madison, WI); Klein, Jonathan L. (Madison, WI)

    1997-10-21T23:59:59.000Z

    An X-ray source such as a synchrotron which provides a significant spectral content of hard X-rays is used to expose relatively thick photoresist such that the portions of the photoresist at an exit surface receive at least a threshold dose sufficient to render the photoresist susceptible to a developer, while the entrance surface of the photoresist receives an exposure which does not exceed a power limit at which destructive disruption of the photoresist would occur. The X-ray beam is spectrally shaped to substantially eliminate lower energy photons while allowing a substantial flux of higher energy photons to pass through to the photoresist target. Filters and the substrate of the X-ray mask may be used to spectrally shape the X-ray beam. Machining of photoresists such as polymethylmethacrylate to micron tolerances may be obtained to depths of several centimeters, and multiple targets may be exposed simultaneously. The photoresist target may be rotated and/or translated in the beam to form solids of rotation and other complex three-dimensional structures.

  3. Method and apparatus for micromachining using hard X-rays

    DOE Patents [OSTI]

    Siddons, D.P.; Johnson, E.D.; Guckel, H.; Klein, J.L.

    1997-10-21T23:59:59.000Z

    An X-ray source such as a synchrotron which provides a significant spectral content of hard X-rays is used to expose relatively thick photoresist such that the portions of the photoresist at an exit surface receive at least a threshold dose sufficient to render the photoresist susceptible to a developer, while the entrance surface of the photoresist receives an exposure which does not exceed a power limit at which destructive disruption of the photoresist would occur. The X-ray beam is spectrally shaped to substantially eliminate lower energy photons while allowing a substantial flux of higher energy photons to pass through to the photoresist target. Filters and the substrate of the X-ray mask may be used to spectrally shape the X-ray beam. Machining of photoresists such as polymethylmethacrylate to micron tolerances may be obtained to depths of several centimeters, and multiple targets may be exposed simultaneously. The photoresist target may be rotated and/or translated in the beam to form solids of rotation and other complex three-dimensional structures. 21 figs.

  4. A multi-crystal wavelength dispersive x-ray spectrometer

    SciTech Connect (OSTI)

    Alonso-Mori, Roberto; Montanez, Paul; Delor, James; Bergmann, Uwe [LCLS, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Kern, Jan [LCLS, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720-8099 (United States); Sokaras, Dimosthenis; Weng, Tsu-Chien; Nordlund, Dennis [SSRL, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Tran, Rosalie; Yachandra, Vittal K.; Yano, Junko [Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720-8099 (United States)

    2012-07-15T23:59:59.000Z

    A multi-crystal wavelength dispersive hard x-ray spectrometer with high-energy resolution and large solid angle collection is described. The instrument is specifically designed for time-resolved applications of x-ray emission spectroscopy (XES) and x-ray Raman scattering (XRS) at X-ray Free Electron Lasers (XFEL) and synchrotron radiation facilities. It also simplifies resonant inelastic x-ray scattering (RIXS) studies of the whole 2d RIXS plane. The spectrometer is based on the Von Hamos geometry. This dispersive setup enables an XES or XRS spectrum to be measured in a single-shot mode, overcoming the scanning needs of the Rowland circle spectrometers. In conjunction with the XFEL temporal profile and high-flux, it is a powerful tool for studying the dynamics of time-dependent systems. Photo-induced processes and fast catalytic reaction kinetics, ranging from femtoseconds to milliseconds, will be resolvable in a wide array of systems circumventing radiation damage.

  5. Viewing spin structures with soft x-ray microscopy

    SciTech Connect (OSTI)

    Fischer, Peter

    2010-06-01T23:59:59.000Z

    The spin of the electron and its associated magnetic moment marks the basic unit for magnetic properties of matter. Magnetism, in particular ferromagnetism and antiferromagnetism is described by a collective order of these spins, where the interaction between individual spins reflects a competition between exchange, anisotropy and dipolar energy terms. As a result the energetically favored ground state of a ferromagnetic system is a rather complex spin configuration, the magnetic domain structure. Magnetism is one of the eldest scientific phenomena, yet it is one of the most powerful and versatile utilized physical effects in modern technologies, such as in magnetic storage and sensor devices. To achieve highest storage density, the relevant length scales, such as the bit size in disk drives is now approaching the nanoscale and as such further developments have to deal with nanoscience phenomena. Advanced characterization tools are required to fully understand the underlying physical principles. Magnetic microscopes using polarized soft X-rays offer a close-up view into magnetism with unique features, these include elemental sensitivity due to X-ray magnetic dichroism effects as contrast mechanism, high spatial resolution provided by state-of-the-art X-ray optics and fast time resolution limited by the inherent time structure of current X-ray sources, which will be overcome with the introduction of ultrafast and high brilliant X-ray sources.

  6. A Soft X-Ray Lag Detected in Centaurus A

    E-Print Network [OSTI]

    Tachibana, Yutaro; Ueda, Yoshihiro; Shidatsu, Megumi; Arimoto, Makoto; Yoshii, Taketoshi; Yatsu, Yoichi; Saito, Yoshihiko; Pike, Sean; Kawai, Nobuyuki

    2015-01-01T23:59:59.000Z

    We performed time lag analysis on the X-ray light curves of Centaurus A (Cen A) obtained by the Gas Slit Camera (GSC) aboard the Monitor of All-sky X-ray Image (MAXI) in three energy bands (2--4 keV, 4--10 keV, and 10--20 keV). We discovered a soft X-ray lag relative to higher energies (soft lag) on a time scale of days by employing the discrete correlation function (DCF) and the z-transformed discrete correlation function (ZDCF) method in a flare episode. A peak in the DCF and the ZDCF was observed at a soft lag of $\\sim 5$ days in 2--4 keV versus 4--10 keV and in 4--10 keV versus 10--20 keV, and $\\sim 10$ days in 2--4 keV versus 10--20 keV. We found it difficult to explain the observed X-ray variation with the one-zone synchrotron self-Compton (SSC) model, in which the soft lags reflect the different cooling times of the relativistic electrons in these three energy bands. Alternatively, if the X-ray variation was produced in a corona surrounding or along the inner part of the accretion disk, we can explain ...

  7. The History of X-ray Free-Electron Lasers

    SciTech Connect (OSTI)

    Pellegrini, C.; /UCLA /SLAC; ,

    2012-06-28T23:59:59.000Z

    The successful lasing at the SLAC National Accelerator Laboratory of the Linear Coherent Light Source (LCLS), the first X-ray free-electron laser (X-ray FEL), in the wavelength range 1.5 to 15 {angstrom}, pulse duration of 60 to few femtoseconds, number of coherent photons per pulse from 10{sup 13} to 10{sup 11}, is a landmark event in the development of coherent electromagnetic radiation sources. Until now electrons traversing an undulator magnet in a synchrotron radiation storage ring provided the best X-ray sources. The LCLS has set a new standard, with a peak X-ray brightness higher by ten orders of magnitudes and pulse duration shorter by three orders of magnitudes. LCLS opens a new window in the exploration of matter at the atomic and molecular scales of length and time. Taking a motion picture of chemical processes in a few femtoseconds or less, unraveling the structure and dynamics of complex molecular systems, like proteins, are some of the exciting experiments made possible by LCLS and the other X-ray FELs now being built in Europe and Asia. In this paper, we describe the history of the many theoretical, experimental and technological discoveries and innovations, starting from the 1960s and 1970s, leading to the development of LCLS.

  8. ON THE X-RAY OUTBURSTS OF TRANSIENT ANOMALOUS X-RAY PULSARS AND SOFT GAMMA-RAY REPEATERS

    SciTech Connect (OSTI)

    Cal Latin-Small-Letter-Dotless-I skan, Sirin; Ertan, Uenal [Sabanc Latin-Small-Letter-Dotless-I University, Orhanl Latin-Small-Letter-Dotless-I -Tuzla, Istanbul, 34956 (Turkey)

    2012-10-20T23:59:59.000Z

    We show that the X-ray outburst light curves of four transient anomalous X-ray pulsars (AXPs) and soft gamma-ray repeaters (SGRs), namely, XTE J1810-197, SGR 0501+4516, SGR 1627-41, and CXOU J164710.2-455216, can be produced by the fallback disk model that was also applied to the outburst light curves of persistent AXPs and SGRs in our earlier work. The model solves the diffusion equation for the relaxation of a disk that has been pushed back by a soft gamma-ray burst. The sets of main disk parameters used for these transient sources are very similar to each other and to those employed in our earlier models of persistent AXPs and SGRs. There is a characteristic difference between the X-ray outburst light curves of transient and persistent sources. This can be explained by the differences in the disk surface density profiles of the transient and persistent sources in quiescence indicated by their quiescent X-ray luminosities. Our results imply that a viscous disk instability operating at a critical temperature in the range of {approx}1300-2800 K is a common property of all fallback disks around AXPs and SGRs. The effect of the instability is more pronounced and starts earlier for the sources with lower quiescent luminosities, which leads to the observable differences in the X-ray enhancement light curves of transient and persistent sources. A single active disk model with the same basic disk parameters can account for the enhancement phases of both transient and persistent AXPs and SGRs. We also present a detailed parameter study to show the effects of disk parameters on the evolution of the X-ray luminosity of AXPs and SGRs in the X-ray enhancement phases.

  9. Quantized hard-x-ray phase vortices nucleated by aberrated nanolenses

    SciTech Connect (OSTI)

    Pavlov, Konstantin M. [School of Science and Technology, University of New England, Armidale, New South Wales 2351 (Australia); School of Physics, Monash University, Victoria 3800 (Australia); Paganin, David M. [School of Physics, Monash University, Victoria 3800 (Australia); Vine, David J. [ARC Centre of Excellence for Coherent X-ray Science, School of Physics, The University of Melbourne, Parkville, Victoria 3010 (Australia); Schmalz, Jelena A. [School of Science and Technology, University of New England, Armidale, New South Wales 2351 (Australia); Suzuki, Yoshio; Uesugi, Kentaro; Takeuchi, Akihisa; Yagi, Naoto [SPring-8/JASRI (Japan Synchrotron Radiation Research Institute), Hyogo 679-5198 (Japan); Kharchenko, Alexander; Blaj, Gabriel [PANalytical B.V., P.O. Box 13, 7600 AA Almelo (Netherlands); Jakubek, Jan [Institute of Experimental and Applied Physics, Czech Technical University in Prague, 166 36 Prague 6 (Czech Republic); Altissimo, Matteo [Melbourne Centre for Nanofabrication, 151 Wellington Road, Clayton, Victoria 3168 (Australia); Materials Science and Engineering, Commonwealth Scientific and Industrial Research Organisation, Clayton South, Victoria 3169 (Australia); Clark, Jesse N. [London Centre for Nanotechnology, University College, Gower St, London WC1E 6BT (United Kingdom)

    2011-01-15T23:59:59.000Z

    Quantized x-ray phase vortices, namely, screw-type topological defects in the wave fronts of a coherent monochromatic scalar x-ray wave field, may be spontaneously nucleated by x-ray lenses. Phase retrieval is used to reconstruct the phase and amplitude of the complex disturbance created by aberrated gold nanolenses illuminated with hard x rays. A nanoscale quantized x-ray vortex-antivortex dipole is observed, manifest both as a pair of opposite-helicity branch points in the Riemann sheets of the multivalued x-ray phase map of the complex x-ray field and in the vorticity of the associated Poynting vector field.

  10. In situ synchrotron based x-ray techniques as monitoring tools for atomic layer deposition

    SciTech Connect (OSTI)

    Devloo-Casier, Kilian, E-mail: Kilian.DevlooCasier@Ugent.be; Detavernier, Christophe; Dendooven, Jolien [Department of Solid State Sciences, Ghent University, Krijgslaan 281/S1, B-9000 Ghent (Belgium); Ludwig, Karl F. [Physics Department, Boston University, 590 Commonwealth Avenue, Boston, Massachusetts 02215 (United States)

    2014-01-15T23:59:59.000Z

    Atomic layer deposition (ALD) is a thin film deposition technique that has been studied with a variety of in situ techniques. By exploiting the high photon flux and energy tunability of synchrotron based x-rays, a variety of new in situ techniques become available. X-ray reflectivity, grazing incidence small angle x-ray scattering, x-ray diffraction, x-ray fluorescence, x-ray absorption spectroscopy, and x-ray photoelectron spectroscopy are reviewed as possible in situ techniques during ALD. All these techniques are especially sensitive to changes on the (sub-)nanometer scale, allowing a unique insight into different aspects of the ALD growth mechanisms.

  11. Hard X-rays from Emission Line Galaxies and the X-ray Background: A Test for Advection Dominated Accretion with Radio Sources

    E-Print Network [OSTI]

    Insu Yi; Stephen P. Boughn

    1997-10-14T23:59:59.000Z

    Recent studies of the cosmic X-ray background (XRB) have suggested the possible existence of a population of relatively faint sources with hard X-ray spectra; however, the emission mechanism remains unclear. If the hard X-ray emission is from the radiatively inefficient, advection dominated accretion flows (ADAFs) around massive black holes in galactic nuclei, X-ray luminosity and radio luminosity satisfy the approximate relation $L_R\\sim 7\\times 10^{35}(\

  12. Eta Car and Its Surroundings: the X-ray Diagnosis

    E-Print Network [OSTI]

    M. F. Corcoran; K. Hamaguchi

    2007-03-02T23:59:59.000Z

    X-ray emission from the supermassive star Eta Carinae (\\ec) originates from hot shocked gas produced by current stellar mass loss as well as ejecta from prior eruptive events. Absorption of this emission by cool material allows the determination of the spatial and temporal distribution of this material. Emission from the shocked gas can provide important information about abundances through the study of thermal X-ray line emission. We discuss how studies of the X-ray emission from Eta Car at a variety of temporal, spatial and spectral scales and resolutions have helped refine our knowledge of both the continuous and discrete mass loss from the system, and its interactions with more extended material around the star.

  13. Counterparts to the Nuclear Bulge X-ray source population

    E-Print Network [OSTI]

    Andrew J. Gosling; Reba M. Bandyopadhyay; Katherine M. Blundell; Phil Lucas

    2008-06-25T23:59:59.000Z

    We present an initial matching of the source positions of the Chandra Nuclear Bulge X-ray sources to the new UKIDSS-GPS near-infrared survey of the Nuclear Bulge. This task is made difficult by the extremely crowded nature of the region, despite this, we find candidate counterparts to ~50% of the X-ray sources. We show that detection in the J-band for a candidate counterpart to an X-ray source preferentially selects those candidate counterparts in the foreground whereas candidate counterparts with only detections in the H and K-bands are more likely to be Nuclear Bulge sources. We discuss the planned follow-up for these candidate counterparts.

  14. Biological imaging by soft x-ray diffraction microscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Shapiro, D. [Stony Brook Univ., Stony Brook, NY (United States); Thibault, P. [Cornell Univ., Ithaca, NY (United States); Beetz, T. [Stony Brook Univ., Stony Brook, NY (United States); Brookhaven National Lab., Upton, NY (United States). Center for Functional Nanomaterials; Elser, V. [Cornell Univ., Ithaca, NY (United States); Howells, M. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Advanced Light Source; Jacobsen, C. [Stony Brook Univ., Stony Brook, NY (United States); Brookhaven National Lab., Upton, NY (United States). Center for Functional Nanomaterials; Kirz, J. [Stony Brook Univ., Stony Brook, NY (United States); Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Advanced Light Source; Lima, E. [Stony Brook Univ., Stony Brook, NY (United States); Miao, H. [Stony Brook Univ., Stony Brook, NY (United States); Neiman, A. M. [State Univ. of New York at Stony Brook, NY (United States); Sayre, D. [Stony Brook Univ., Stony Brook, NY (United States)

    2005-10-25T23:59:59.000Z

    We have used the method of x-ray diffraction microscopy to image the complex-valued exit wave of an intact and unstained yeast cell. The images of the freeze-dried cell, obtained by using 750-eV x-rays from different angular orientations, portray several of the cell's major internal components to 30-nm resolution. The good agreement among the independently recovered structures demonstrates the accuracy of the imaging technique. To obtain the best possible reconstructions, we have implemented procedures for handling noisy and incomplete diffraction data, and we propose a method for determining the reconstructed resolution. This work represents a previously uncharacterized application of x-ray diffraction microscopy to a specimen of this complexity and provides confidence in the feasibility of the ultimate goal of imaging biological specimens at 10-nm resolution in three dimensions.

  15. Non-thermal X-ray Emission from Supernova Remnants

    E-Print Network [OSTI]

    Jacco Vink

    2004-09-21T23:59:59.000Z

    Recent studies of narrow, X-ray synchrotron radiating filaments surrounding young supernova remnants indicate that magnetic fields strengths are relatively high, B ~ 0.1 mG, or even higher, and that diffusion is close to the Bohm limit. I illustrate this using Cas A as an example. Also older remnants such as RCW 86 appear to emit X-ray synchrotron radiation, but the emission is more diffuse, and not always confined to a region close to the shock front. I argue that for RCW 86 the magnetic field is likely to be low (B ~ 17 microGauss), and at the location where the shell emits X-ray synchrotron radiation the shock velocity is much higher than the average shock velocity of ~600 km/s.

  16. X-ray radiography with highly charged ions

    DOE Patents [OSTI]

    Marrs, Roscoe E. (Livermore, CA)

    2000-01-01T23:59:59.000Z

    An extremely small (1-250 micron FWHM) beam of slow highly charged ions deexciting on an x-ray production target generates x-ray monochromatic radiation that is passed through a specimen and detected for imaging. The resolution of the x-ray radiograms is improved and such detection is achieved with relatively low dosages of radiation passing through the specimen. An apparatus containing an electron beam ion trap (and modifications thereof) equipped with a focusing column serves as a source of ions that generate radiation projected onto an image detector. Electronic and other detectors are able to detect an increased amount of radiation per pixel than achieved by previous methods and apparati.

  17. Movable anode x-ray source with enhanced anode cooling

    DOE Patents [OSTI]

    Bird, C.R.; Rockett, P.D.

    1987-08-04T23:59:59.000Z

    An x-ray source is disclosed having a cathode and a disc-shaped anode with a peripheral surface at constant radius from the anode axis opposed to the cathode. The anode has stub axle sections rotatably carried in heat conducting bearing plates which are mounted by thermoelectric coolers to bellows which normally bias the bearing plates to a retracted position spaced from opposing anode side faces. The bellows cooperate with the x-ray source mounting structure for forming closed passages for heat transport fluid. Flow of such fluid under pressure expands the bellows and brings the bearing plates into heat conducting contact with the anode side faces. A worm gear is mounted on a shaft and engages serrations in the anode periphery for rotating the anode when flow of coolant is terminated between x-ray emission events. 5 figs.

  18. Movable anode x-ray source with enhanced anode cooling

    DOE Patents [OSTI]

    Bird, Charles R. (Ypsilanti, MI); Rockett, Paul D. (Ann Arbor, MI)

    1987-01-01T23:59:59.000Z

    An x-ray source having a cathode and a disc-shaped anode with a peripheral surface at constant radius from the anode axis opposed to the cathode. The anode has stub axle sections rotatably carried in heat conducting bearing plates which are mounted by thermoelectric coolers to bellows which normally bias the bearing plates to a retracted position spaced from opposing anode side faces. The bellows cooperate with the x-ray source mounting structure for forming closed passages for heat transport fluid. Flow of such fluid under pressure expands the bellows and brings the bearing plates into heat conducting contact with the anode side faces. A worm gear is mounted on a shaft and engages serrations in the anode periphery for rotating the anode when flow of coolant is terminated between x-ray emission events.

  19. Portable X-Ray, K-Edge Heavy Metal Detector

    SciTech Connect (OSTI)

    Fricke, V.

    1999-10-25T23:59:59.000Z

    The X-Ray, K-Edge Heavy Metal Detection System was designed and built by Ames Laboratory and the Center for Nondestructive Evaluation at Iowa State University. The system uses a C-frame inspection head with an X-ray tube mounted on one side of the frame and an imaging unit and a high purity germanium detector on the other side. the inspection head is portable and can be easily positioned around ventilation ducts and pipes up to 36 inches in diameter. Wide angle and narrow beam X-ray shots are used to identify the type of holdup material and the amount of the contaminant. Precise assay data can be obtained within minutes of the interrogation. A profile of the containerized holdup material and a permanent record of the measurement are immediately available.

  20. The nature of the Vela X-ray "jet"

    E-Print Network [OSTI]

    V. V. Gvaramadze

    1999-12-02T23:59:59.000Z

    The nature of the Vela X-ray "jet", recently discovered by Markwardt & \\"Ogelman (1995), is examined. It is suggested that the "jet" arises along the interface of domelike deformations of the Rayleigh-Taylor unstable shell of the Vela supernova remnant; thereby the "jet" is interpreted as a part of the general shell of the remnant. The origin of deformations as well as the general structure of the remnant are discussed in the framework of a model based on a cavity explosion of a supernova star. It is suggested that the shell deformations viewed at various angles appear as filamentary structures visible throughout the Vela supernova remnant at radio, optical, and X-ray wavelengths. A possible origin of the nebula of hard X-ray emission detected by Willmore et al. (1992) around the Vela pulsar is proposed.

  1. Archaeometrical studies using X-ray fluorescence methods

    SciTech Connect (OSTI)

    Pauna, Catalina; Constantinescu, B.; Constantin, F.; Bugoi, R.; Stan, D.; Vasilescu, A. [National Institute of Nuclear Physics and Engineering, POB MG-6, 077125, Bucharest (Romania)

    2010-04-26T23:59:59.000Z

    Elemental analysis contributes to authentication (knowing the elemental composition and considering the information about the usual composition of the objects in different historical periods it can be established if the item is original or fake), provenance studies (minor and trace elements indicates ores origin and 'consequently' mines location), (relative) dating of archaeological objects (e.g. for painted items--the chemical recipes for pigments can offer information about the age of objects). The paper gives a general layout for the NIPNE Archaeometry Laboratory's applications using X-Ray Fluorescence (XRF), micro--Proton Induced X-Ray Emission (micro-PIXE), micro-Synchrotron Radiation Induced X-Ray Fluorescence (micro--SR-XRF) methods.

  2. Fundamental physics at an X-ray free electron laser

    E-Print Network [OSTI]

    A. Ringwald

    2001-12-19T23:59:59.000Z

    X-ray free electron lasers (FELs) have been proposed to be constructed both at SLAC in the form of the so-called Linac Coherent Light Source as well as at DESY, where the so-called XFEL laboratory is part of the design of the electron-positron linear collider TESLA. In addition to the immediate applications in condensed matter physics, chemistry, material science, and structural biology, X-ray FELs may be employed also to study some physics issues of fundamental nature. In this context, one may mention the boiling of the vacuum (Schwinger pair creation in an external field), horizon physics (Unruh effect), and axion production. We review these X-ray FEL opportunities of fundamental physics and discuss the necessary technological improvements in order to achieve these goals.

  3. Imaging X-ray Thomson Scattering Spectrometer Design and Demonstration

    SciTech Connect (OSTI)

    Gamboa, E.J. [University of Michigan; Huntington, C.M. [University of Michigan; Trantham, M.R. [University of Michigan; Keiter, P.A [University of Michigan; Drake, R.P. [University of Michigan; Montgomery, David [Los Alamos National Laboratory; Benage, John F. [Los Alamos National Laboratory; Letzring, Samuel A. [Los Alamos National Laboratory

    2012-05-04T23:59:59.000Z

    In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally-curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

  4. Quiescent X-ray emission from an evolved brown dwarf ?

    E-Print Network [OSTI]

    B. Stelzer

    2004-09-27T23:59:59.000Z

    I report on the X-ray detection of Gl569Bab. During a 25ksec Chandra observation the binary brown dwarf is for the first time spatially separated in X-rays from the flare star primary Gl569A. Companionship to Gl569A constrains the age of the brown dwarf pair to ~300-800 Myr. The observation presented here is only the second X-ray detection of an evolved brown dwarf. About half of the observing time is dominated by a large flare on Gl569Bab, the remainder is characterized by weak and non-variable emission just above the detection limit. This emission -- if not related to the afterglow of the flare -- represents the first detection of a quiescent corona on a brown dwarf, representing an important piece in the puzzle of dynamos in the sub-stellar regime.

  5. X-ray microscope assemblies. Final report and metrology report

    SciTech Connect (OSTI)

    Zehnpfennig, T.F.

    1981-04-13T23:59:59.000Z

    This is the Final Report and Metrology Report prepared under Lawrence Livermore Laboratory Subcontract 9936205, X-ray Microscope Assemblies. The purpose of this program was to design, fabricate, and perform detailed metrology on an axisymmetric grazing-incidence x-ray microscope (XRMS) to be used as a diagnostic instrument in the Lawrence Livermore Laser Fusion Program. The optical configuration chosen for this device consists of two internally polished surfaces of revolution: an hyperboloid facing the object; and a confocal, co-axial elliposid facing the image. This arrangement is known as the Wolter Type-I configuration. The grazing angle of reflection for both surfaces is approximately 1/sup 0/. The general optical performance goals under this program were to achieve a spatial resolution in the object plane in the soft x-ray region of approximately 1 micron, and to achieve an effective solid collecting angle which is an appreciable fraction of the geometric solid collecting angle.

  6. Biological Imaging by Soft X-ray Diffraction Microscopy

    SciTech Connect (OSTI)

    Shapiro,D.; Thibault, P.; Beetz, T.; Elser, V.; Howells, M.; Jacobsen, C.; Kirz, J.; Lima, E.; Miao, H.; et al.

    2005-01-01T23:59:59.000Z

    We have used the method of x-ray diffraction microscopy to image the complex-valued exit wave of an intact and unstained yeast cell. The images of the freeze-dried cell, obtained by using 750-eV x-rays from different angular orientations, portray several of the cell's major internal components to 30-nm resolution. The good agreement among the independently recovered structures demonstrates the accuracy of the imaging technique. To obtain the best possible reconstructions, we have implemented procedures for handling noisy and incomplete diffraction data, and we propose a method for determining the reconstructed resolution. This work represents a previously uncharacterized application of x-ray diffraction microscopy to a specimen of this complexity and provides confidence in the feasibility of the ultimate goal of imaging biological specimens at 10-nm resolution in three dimensions.

  7. Advances in the Detection of As in Environmental Samples Using Low Energy X-ray Fluorescence in a Scanning Transmission X-ray

    E-Print Network [OSTI]

    Hitchcock, Adam P.

    X-ray emission (PIXE),4 or energy dispersive X-ray (EDX) spectrometry in scanning or transmission XAdvances in the Detection of As in Environmental Samples Using Low Energy X-ray Fluorescence at high spatial resolution is needed in many areas of geobiochemistry and environmental science. Scanning

  8. Advances in X-Ray Chemical Analysis, Japan, 45 (2014) ISSN 0911-7806 Report on 10th Chinese X-Ray Spectrometry Conference (CXRSC)

    E-Print Network [OSTI]

    Jun, Kawai

    and Information Technology), Dr. Yidong Zhao (Institute of High Energy Physics of Chinese Academy of Sciences-Ray Spectrometry Conference (CXRSC) Ying LIU #12;#12;45 345 Report on 10th Chinese X-Ray Spectrometry Conference (CXRSC) Adv. X-Ray. Chem. Anal., Japan 45, pp.345-348 (2014) Report on 10th Chinese X-Ray Spectrometry

  9. Probing stellar winds and accretion physics in high-mass X-ray binaries and ultra-luminous X-ray sources with LOFT

    E-Print Network [OSTI]

    Orlandini, M; Zampieri, L; Bozzo, E; Baykal, A; Blay, P; Chernyakova, M; Corbet, R; D'Aě, A; Enoto, T; Ferrigno, C; Finger, M; Klochkov, D; Kreykenbohm, I; Inam, S C; Jenke, P; Masetti, N; Manousakis, A; Mihara, T; Paul, B; Postnov, K; Reig, P; Romano, P; Santangelo, A; Shakura, N; Staubert, R; Torrejón, J M; Walter, R; Wilms, J; Wilson-Hodge, C

    2015-01-01T23:59:59.000Z

    This is a White Paper in support of the mission concept of the Large Observatory for X-ray Timing (LOFT), proposed as a medium-sized ESA mission. We discuss the potential of LOFT for the study of high-mass X-ray binaries and ultra-luminous X-ray sources. For a summary, we refer to the paper.

  10. High-resolution X-ray spectroscopy of Theta Car

    E-Print Network [OSTI]

    Yael Naze; Gregor Rauw

    2008-08-25T23:59:59.000Z

    Context : The peculiar hot star Theta Car in the open cluster IC2602 is a blue straggler as well as a single-line binary of short period (2.2d). Aims : Its high-energy properties are not well known, though X-rays can provide useful constraints on the energetic processes at work in binaries as well as in peculiar, single objects. Methods : We present the analysis of a 50ks exposure taken with the XMM-Newton observatory. It provides medium as well as high-resolution spectroscopy. Results : Our high-resolution spectroscopy analysis reveals a very soft spectrum with multiple temperature components (1--6MK) and an X-ray flux slightly below the `canonical' value (log[L_X(0.1-10.)/L_{BOL}] ~ -7). The X-ray lines appear surprisingly narrow and unshifted, reminiscent of those of beta Cru and tau Sco. Their relative intensities confirm the anomalous abundances detected in the optical domain (C strongly depleted, N strongly enriched, O slightly depleted). In addition, the X-ray data favor a slight depletion in neon and iron, but they are less conclusive for the magnesium abundance (solar-like?). While no significant changes occur during the XMM-Newton observation, variability in the X-ray domain is detected on the long-term range. The formation radius of the X-ray emission is loosely constrained to <5 R_sol, which allows for a range of models (wind-shock, corona, magnetic confinement,...) though not all of them can be reconciled with the softness of the spectrum and the narrowness of the lines.

  11. X-RAY BINARY EVOLUTION ACROSS COSMIC TIME

    SciTech Connect (OSTI)

    Fragos, T.; Zezas, A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)] [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Lehmer, B.; Tzanavaris, P. [Department of Physics and Astronomy, The Johns Hopkins University, Homewood Campus, Baltimore, MD 21218 (United States)] [Department of Physics and Astronomy, The Johns Hopkins University, Homewood Campus, Baltimore, MD 21218 (United States); Tremmel, M. [Department of Astronomy, University of Washington, Box 351580, U.W., Seattle, WA 98195-1580 (United States)] [Department of Astronomy, University of Washington, Box 351580, U.W., Seattle, WA 98195-1580 (United States); Basu-Zych, A.; Hornschemeier, A.; Jenkins, L.; Ptak, A. [NASA Goddard Space Flight Centre, Code 662, Greenbelt, MD 20771 (United States)] [NASA Goddard Space Flight Centre, Code 662, Greenbelt, MD 20771 (United States); Belczynski, K. [Astronomical Observatory, University of Warsaw, Al. Ujazdowskie 4, 00-478 Warsaw (Poland)] [Astronomical Observatory, University of Warsaw, Al. Ujazdowskie 4, 00-478 Warsaw (Poland); Kalogera, V., E-mail: tfragos@cfa.harvard.edu [Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States)

    2013-02-10T23:59:59.000Z

    High-redshift galaxies permit the study of the formation and evolution of X-ray binary (XRB) populations on cosmological timescales, probing a wide range of metallicities and star formation rates (SFRs). In this paper, we present results from a large-scale population synthesis study that models the XRB populations from the first galaxies of the universe until today. We use as input to our modeling the Millennium II cosmological simulation and the updated semi-analytic galaxy catalog by Guo et al. to self-consistently account for the star formation history and metallicity evolution of the universe. Our modeling, which is constrained by the observed X-ray properties of local galaxies, gives predictions about the global scaling of emission from XRB populations with properties such as SFR and stellar mass, and the evolution of these relations with redshift. Our simulations show that the X-ray luminosity density (X-ray luminosity per unit volume) from XRBs in our universe today is dominated by low-mass XRBs, and it is only at z {approx}> 2.5 that high-mass XRBs become dominant. We also find that there is a delay of {approx}1.1 Gyr between the peak of X-ray emissivity from low-mass XRBs (at z {approx} 2.1) and the peak of SFR density (at z {approx} 3.1). The peak of the X-ray luminosity from high-mass XRBs (at z {approx} 3.9) happens {approx}0.8 Gyr before the peak of the SFR density, which is due to the metallicity evolution of the universe.

  12. X Ray Precursors in SGRs: Precessing Gamma Jet Tails

    E-Print Network [OSTI]

    Daniele Fargion

    2001-05-18T23:59:59.000Z

    Weak isolated X-ray precursor events before the main Gamma Ray Burst, GRB, and also rare Soft Gamma Repeaters, SGR, events are in complete disagreement with any Fireball, or Magnetar, one-shoot explosive scenarios. Fireball model in last two years has been deeply modified into a fountain beamed Jet exploding and interacting on external shells to explain GRB fine time structure. On the contrary earlier we proposed a unified scenario for both GRBs-SGRs where a precessing Gamma Jet (of different intensity) and its geometrical beaming is the source of both GRB and SGRs wide morphology. GRBs are peaked SNs Jet spinning and precessing observed along the thin Jet axis. Their mysterious weak X precursors bursts, corresponding to non-negligible energy powers, up to million Supernova ones for GRB, are gamma Jet tails beamed off-axis, observed at X-Ray tails. They are rare, about (3-6)% of all GRBs, but not unique at all. Comparable brief X-ray precursor flashes occurred in rarest and most detailed SGRs events as the 27 and the 29 August 1998 event from SGR 1900+14. The same source has been in very power-full activity on recent 18 April 2001 once again preceded by X-Ray precursors. These events are inconsistent with any Fireball or Magnetar-Mini-Fireball models. We interpret them naturally as earlier marginal blazing of outlying X conical precessing Jet, an off-axis tails surrounding a narrower gamma precessing Jet. Only when the light-house Jet is in on-axis blazing mode toward the Earth we observe the harder power-full SGR event. We predict such a rich X-Ray precursor signals (more numerous then gamma ones) during Soft Gamma Repeater peak activities; they should be abundant and within detection threshold by a permanent monitoring SGRs by Beppo-Sax WFC or Chandra X ray satellites while at peak activity.

  13. X-ray imaging crystal spectroscopy for use in plasma transport research

    SciTech Connect (OSTI)

    Reinke, M. L.; Podpaly, Y. A.; Hutchinson, I. H.; Rice, J. E.; Gao, C.; Greenwald, M.; Howard, N. T.; Hubbard, A.; Hughes, J. W.; White, A. E.; Wolfe, S. M. [MIT-Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Bitter, M.; Delgado-Aparicio, L.; Hill, K.; Pablant, N. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2012-11-15T23:59:59.000Z

    This research describes advancements in the spectral analysis and error propagation techniques associated with x-ray imaging crystal spectroscopy (XICS) that have enabled this diagnostic to be used to accurately constrain particle, momentum, and heat transport studies in a tokamak for the first time. Doppler tomography techniques have been extended to include propagation of statistical uncertainty due to photon noise, the effect of non-uniform instrumental broadening as well as flux surface variations in impurity density. These methods have been deployed as a suite of modeling and analysis tools, written in interactive data language (IDL) and designed for general use on tokamaks. Its application to the Alcator C-Mod XICS is discussed, along with novel spectral and spatial calibration techniques. Example ion temperature and radial electric field profiles from recent I-mode plasmas are shown, and the impact of poloidally asymmetric impurity density and natural line broadening is discussed in the context of the planned ITER x-ray crystal spectrometer.

  14. Sparse signal reconstruction from polychromatic X-ray CT measurements via mass attenuation discretization

    SciTech Connect (OSTI)

    Gu, Renliang; Dogandži?, Aleksandar [Iowa State University, Center for Nondestructive Evaluation, 1915 Scholl Road, Ames, IA 50011 (United States)

    2014-02-18T23:59:59.000Z

    We propose a method for reconstructing sparse images from polychromatic x-ray computed tomography (ct) measurements via mass attenuation coefficient discretization. The material of the inspected object and the incident spectrum are assumed to be unknown. We rewrite the Lambert-Beer’s law in terms of integral expressions of mass attenuation and discretize the resulting integrals. We then present a penalized constrained least-squares optimization approach for reconstructing the underlying object from log-domain measurements, where an active set approach is employed to estimate incident energy density parameters and the nonnegativity and sparsity of the image density map are imposed using negative-energy and smooth ?{sub 1}-norm penalty terms. We propose a two-step scheme for refining the mass attenuation discretization grid by using higher sampling rate over the range with higher photon energy, and eliminating the discretization points that have little effect on accuracy of the forward projection model. This refinement allows us to successfully handle the characteristic lines (Dirac impulses) in the incident energy density spectrum. We compare the proposed method with the standard filtered backprojection, which ignores the polychromatic nature of the measurements and sparsity of the image density map. Numerical simulations using both realistic simulated and real x-ray ct data are presented.

  15. Region-of-interest reconstructions from truncated 3D x-ray projections

    E-Print Network [OSTI]

    Robert Azencott; Bernhard G. Bodmann; Demetrio Labate; Anando Sen; Daniel Vera

    2015-02-04T23:59:59.000Z

    This paper introduces a method of region-of-interest (ROI) reconstruction from truncated 3D X-ray projections, consisting of a wavelet-based regularized iterative reconstruction procedure that, under appropriate conditions, converges within the ROI to an exact or highly accurate solution. ROI tomography is motivated by the goal to reduce the overall radiation exposure when primarily the reconstruction of a specified region rather than the entire object is required. Our approach assumes that only the 3D truncated X-ray projections, i.e., the projection data restricted to the image of the ROI, are known and does not assume any previous knowledge about the density function, except for standard assumptions about integrability and regularity needed to ensure that forward and backward transforms are well defined. We provide rigorous theoretical justification for the convergence of our regularized reconstruction algorithm in the continuous setting and prove the existence of a critical radius of a spherical ROI that ensures the convergence of the algorithm. Theoretical results are validated numerically using simulated acquisition and truncation of projection data for various acquisition geometries and ROI sizes and locations. We provide a numerical analysis of the ROI reconstruction stability as a function of the ROI size, showing that our algorithm converges also for ROI sizes which are rather small with respect to the support of the density function.

  16. Bragg x-ray survey spectrometer for ITER

    SciTech Connect (OSTI)

    Varshney, S. K.; Jakhar, S. [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, Gujarat 382428 (India); Barnsley, R. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); O'Mullane, M. G. [Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom)

    2012-10-15T23:59:59.000Z

    Several potential impurity ions in the ITER plasmas will lead to loss of confined energy through line and continuum emission. For real time monitoring of impurities, a seven channel Bragg x-ray spectrometer (XRCS survey) is considered. This paper presents design and analysis of the spectrometer, including x-ray tracing by the Shadow-XOP code, sensitivity calculations for reference H-mode plasma and neutronics assessment. The XRCS survey performance analysis shows that the ITER measurement requirements of impurity monitoring in 10 ms integration time at the minimum levels for low-Z to high-Z impurity ions can largely be met.

  17. The NIF x-ray spectrometer calibration campaign at Omega

    SciTech Connect (OSTI)

    Pérez, F.; Kemp, G. E.; Barrios, M. A.; Pino, J.; Scott, H.; Ayers, S.; Chen, H.; Emig, J.; Colvin, J. D.; Fournier, K. B., E-mail: fournier2@llnl.gov [Lawrence Livermore National Laboratory, P. O. Box 808, Livermore, California 94551 (United States); Regan, S. P.; Bedzyk, M.; Shoup, M. J.; Agliata, A.; Yaakobi, B.; Marshall, F. J.; Hamilton, R. A. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Jaquez, J.; Farrell, M.; Nikroo, A. [General Atomics, P.O. Box 85608, San Diego, California 92186 (United States)

    2014-11-15T23:59:59.000Z

    The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the OMEGA laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2–18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

  18. X-Ray Binary Systems in the Small Magellanic Cloud

    E-Print Network [OSTI]

    P. Kahabka; W. Pietsch

    1997-06-09T23:59:59.000Z

    We present the result of a systematic search for spectrally hard and soft X-ray binary systems in the Small Magellanic Cloud (SMC). This search has been applied to ROSAT PSPC data (0.1-2.4 keV) collected during 9 pointed observations towards this galaxy covering a time span of 2 years from October 91 till October 93. Selection criteria have been defined in order to confine the sample of candidates. Finally 7 spectrally hard and 4 spectrally soft sources were selected from the list as candidates for binaries in the SMC. The sample is luminosity limited (>3.10**35 erg/s). SMC X-1 has been observed during a full binary orbit starting with a low-state covering an X-ray eclipse and emerging into a bright long-duration flare with two short-duration flares separated by 10 hours. The Be type transient SMC X-2 has been redetected with ROSAT. Variability has been found in the sources RX J0051.8-7231 and RX J0052.1-731 already discovered with Einstein. RX J0101.0-7206 has been discovered at the north-eastern boundary of the giant SMC HII region N66 during an X-ray outburst and half a year later during a quiescent phase. A variable source, RX J0049.1-7250, located north-east of the SMC supernova remnant N19 and which may either be an X-ray binary or an AGN turns out to be strongly absorbed. It may be located behind the SMC. If it is an X-ray binary then it radiates at the Eddington limit in the X-ray bright state. Another variable and hard X-ray source RX J0032.9-7348 has been discovered at the south-eastern border of the body of the SMC. A high mass X-ray binary nature is favored for this source. We searched for CAL87 like systems in the SMC catalog and found none. A new candidate supersoft source RX J0103.8-7254 has been detected. We cannot exclude that it is a foreground object.

  19. The dominant X-ray wind in massive star binaries

    E-Print Network [OSTI]

    J. M. Pittard; I. R. Stevens

    2002-04-15T23:59:59.000Z

    We investigate which shocked wind is responsible for the majority of the X-ray emission in colliding wind binaries, an issue where there is some confusion in the literature, and which we show is more complicated than has been assumed. We find that where both winds rapidly cool (typically close binaries), the ratio of the wind speeds is often more important than the momentum ratio, because it controls the energy flux ratio, and the faster wind is generally the dominant emitter. When both winds are largely adiabatic (typically long-period binaries), the slower and denser wind will cool faster and the stronger wind generally dominates the X-ray luminosity.

  20. The First Angstrom X-Ray Free-Electron Laser

    SciTech Connect (OSTI)

    Galayda, John; /SLAC

    2012-08-24T23:59:59.000Z

    The Linac Coherent Light Source produced its first x-ray laser beam on 10 April 2009. Today it is routinely producing x-ray pulses with energy >2 mJ across the operating range from 820-8,200 eV. The facility has begun operating for atomic/molecular/optical science experiments. Performance of the facility in its first user run (1 October - 21 December) and current machine development activities will be presented. Early results from the preparations for the start of the second user run is also reported.

  1. Viscosity in X-ray clusters: Braginskii over 5

    E-Print Network [OSTI]

    A. Gruzinov

    2006-11-07T23:59:59.000Z

    We argue that it is currently impossible to simulate X-ray clusters using correct equations, because even the MHD description is not applicable. But since fluid simulations actually reproduce observations quite well, one may try to improve the fluid codes by including molecular transport of heat and momentum. We calculate the effective molecular viscosity for the simplest model of magnetic field and obtain 1/5 of the Braginskii value, similar to 1/3 of Spitzer for the heat conduction. This is large enough to noticeably damp the X-ray cluster turbulence.

  2. Confusion of Diffuse Objects in the X-ray Sky

    E-Print Network [OSTI]

    G. Mark Voit; August E. Evrard; Greg L. Bryan

    2000-12-08T23:59:59.000Z

    Most of the baryons in the present-day universe are thought to reside in intergalactic space at temperatures of 10^5-10^7 K. X-ray emission from these baryons contributes a modest (~10%) fraction of the ~ 1 keV background whose prominence within the large-scale cosmic web depends on the amount of non-gravitational energy injected into intergalactic space by supernovae and AGNs. Here we show that the virialized regions of groups and clusters cover over a third of the sky, creating a source-confusion problem that may hinder X-ray searches for individual intercluster filaments and contaminate observations of distant groups.

  3. Stratigraphic correlation with X-ray powder patterns

    E-Print Network [OSTI]

    Singletary, John B

    1951-01-01T23:59:59.000Z

    pattern of maxima characteristic of all the principal spacings. For instance, if the radiation detector is set so as to observe the secondary diffracted beam at an angle which satisfies Bragg~s Law for some value of d found in the crystal, then a... focusing x-ray spectrometer manufac- tured by the North American Philips Company for commercial use. This instrument, shown in Fig. RB, consists of an x-ray generating unit, a goniometer, and a Geiger counter radiation detector. The patte ns were...

  4. High-resolution radio observations of X-ray binaries

    E-Print Network [OSTI]

    James Miller-Jones

    2008-09-15T23:59:59.000Z

    I present an overview of important results obtained using high-resolution very long baseline interferometry (VLBI) observations of X-ray binary systems. These results derive from both astrometric observations and resolved imaging of sources, from black holes to neutron star and even white dwarf systems. I outline a number of upcoming developments in instrumentation, both new facilities and ongoing upgrades to existing VLBI instruments, and I conclude by identifying a number of important areas of investigation where VLBI will be crucial in advancing our understanding of X-ray binaries.

  5. Femtosecond Time-Delay X-ray Holography

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist. CategoryFebruaryFebruary 17,Time-Delay X-ray Holography X-ray

  6. Simulation et analyse par tomographie X de la dformation l'chelle msoscopique de renforts textiles de composites en cours de mise en forme

    E-Print Network [OSTI]

    Boyer, Edmond

    like permeability evaluations. A mechanical analysis of the reinforcement at meso-scale is proposed mésoscopique, Hypo-élasticité, Tomographie Keywords : Composite Forming, Finite Element, X-Ray tomography, Meso-scale

  7. Three-dimensional foam flow resolved by fast X-ray tomographic microscopy

    E-Print Network [OSTI]

    Raufaste, Christophe; Mader, Kevin; Santucci, Stéphane; Mokso, Rajmund

    2015-01-01T23:59:59.000Z

    Thanks to ultra fast and high resolution X-ray tomography, we managed to capture the evolution of the local structure of the bubble network of a 3D foam flowing around a sphere. As for the 2D foam flow around a circular obstacle, we observed an axisymmetric velocity field with a recirculation zone, and indications of a negative wake downstream the obstacle. The bubble deformations, quantified by a shape tensor, are smaller than in 2D, due to a purely 3D feature: the azimuthal bubble shape variation. Moreover, we were able to detect plastic rearrangements, characterized by the neighbor-swapping of four bubbles. Their spatial structure suggest that rearrangements are triggered when films faces get smaller than a characteristic area.

  8. Three-dimensional foam flow resolved by fast X-ray tomographic microscopy

    E-Print Network [OSTI]

    Christophe Raufaste; Benjamin Dollet; Kevin Mader; Stéphane Santucci; Rajmund Mokso

    2015-03-19T23:59:59.000Z

    Thanks to ultra fast and high resolution X-ray tomography, we managed to capture the evolution of the local structure of the bubble network of a 3D foam flowing around a sphere. As for the 2D foam flow around a circular obstacle, we observed an axisymmetric velocity field with a recirculation zone, and indications of a negative wake downstream the obstacle. The bubble deformations, quantified by a shape tensor, are smaller than in 2D, due to a purely 3D feature: the azimuthal bubble shape variation. Moreover, we were able to detect plastic rearrangements, characterized by the neighbor-swapping of four bubbles. Their spatial structure suggest that rearrangements are triggered when films faces get smaller than a characteristic area.

  9. Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources

    SciTech Connect (OSTI)

    Sisniega, A.; Vaquero, J. J., E-mail: juanjose.vaquero@uc3m.es [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid ES28911 (Spain); Instituto de Investigación Sanitaria Gregorio Marańón, Madrid ES28007 (Spain); Desco, M. [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid ES28911 (Spain) [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Madrid ES28911 (Spain); Instituto de Investigación Sanitaria Gregorio Marańón, Madrid ES28007 (Spain); Centro de Investigación Biomédica en Red de Salud Mental (CIBERSAM), Madrid ES28029 (Spain)

    2014-01-15T23:59:59.000Z

    Purpose: The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammography. However, most of these models cannot be used directly for modeling microfocus x-ray sources due to differences in inherent filtration, energy range and/or anode material. For this reason the authors propose in this work a new model for the simulation of microfocus spectra based on existing models for mammography and radiology, modified to compensate for the effects of inherent filtration and energy range. Methods: The authors used the radiology and mammography versions of an existing empirical model [tungsten anode spectral model interpolating polynomials (TASMIP)] as the basis of the microfocus model. First, the authors estimated the inherent filtration included in the radiology model by comparing the shape of the spectra with spectra from the mammography model. Afterwards, the authors built a unified spectra dataset by combining both models and, finally, they estimated the parameters of the new version of TASMIP for microfocus sources by calibrating against experimental exposure data from a microfocus x-ray source. The model was validated by comparing estimated and experimental exposure and attenuation data for different attenuating materials and x-ray beam peak energy values, using two different x-ray tubes. Results: Inherent filtration for the radiology spectra from TASMIP was found to be equivalent to 1.68 mm Al, as compared to spectra obtained from the mammography model. To match the experimentally measured exposure data the combined dataset required to apply a negative filtration of about 0.21 mm Al and an anode roughness of 0.003 mm W. The validation of the model against real acquired data showed errors in exposure and attenuation in line with those reported for other models for radiology or mammography. Conclusions: A new version of the TASMIP model for the estimation of x-ray spectra in microfocus x-ray sources has been developed and validated experimentally. Similarly to other versions of TASMIP, the estimation of spectra is very simple, involving only the evaluation of polynomial expressions.

  10. Correlated long-term optical and X-ray variations in NGC 5548

    E-Print Network [OSTI]

    Phil Uttley; Rick Edelson; Ian McHardy; Bradley M. Peterson; Alex Markowitz

    2003-01-13T23:59:59.000Z

    We combine the long-term optical light curve of the Seyfert 1 galaxy NGC5548 with the X-ray light curve measured by the Rossi X-ray Timing Explorer over 6 years, to determine the relationship between the optical and X-ray continua. The X-ray light curve is strongly correlated with the optical light curve on long (~year) time-scales. The amplitude of the long-term optical variability in NGC5548 is larger than that of the X-ray variability (after accounting for the host galaxy contribution), implying that X-ray reprocessing is not the main source of the optical/X-ray correlation. The correlated X-ray and optical variations in NGC5548 may be caused by instabilities in the inner part of the accretion flow, where both the X-ray and optical emission regions may be located.

  11. A mirror for lab-based quasi-monochromatic parallel x-rays

    SciTech Connect (OSTI)

    Nguyen, Thanhhai; Lu, Xun; Lee, Chang Jun; Jeon, Insu, E-mail: i-jeon@chonnam.ac.kr [School of Mechanical Engineering, Chonnam National University, 300 Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of); Jung, Jin-Ho [Pro-optics Co., Ltd., 475 Ami-ri, Bubal-eup, Icheon 467-866 (Korea, Republic of); Jin, Gye-Hwan [Department of Radiology, Nambu University, 76 Chumdan Jungang 1-ro, Gwangsan-gu, Gwangju 506-706 (Korea, Republic of); Kim, Sung Youb [School of Mechanical and Advanced Materials Engineering, Ulsan National Institute of Science and Technology, 100 Banyeon-ri, Eonyang-eup, Ulju-gun, Ulsan 689-798 (Korea, Republic of)

    2014-09-15T23:59:59.000Z

    A multilayered parabolic mirror with six W/Al bilayers was designed and fabricated to generate monochromatic parallel x-rays using a lab-based x-ray source. Using this mirror, curved bright bands were obtained in x-ray images as reflected x-rays. The parallelism of the reflected x-rays was investigated using the shape of the bands. The intensity and monochromatic characteristics of the reflected x-rays were evaluated through measurements of the x-ray spectra in the band. High intensity, nearly monochromatic, and parallel x-rays, which can be used for high resolution x-ray microscopes and local radiation therapy systems, were obtained.

  12. Thermal X-ray composites as an effect of projection

    E-Print Network [OSTI]

    O. Petruk

    2001-03-21T23:59:59.000Z

    A new possibility to explain the nature of thermal X-ray composites (TXCs), i.e. a class of supernova remnants (SNRs) with a thermal X-ray centrally-filled morphology within a radio shell, as a projection effect of the 2- or 3-dimensional shell-like SNR evolved in a nonuniform medium with scale-height <10 pc is proposed. Both X-ray and radio morphologies, as well as the basic theoretical features of this kind of SNR and the surrounding medium, are considered. Theoretical properties of a shell-like SNR evolved at the edge of a molecular cloud correspond to the observed properties of TXCs if the gradient of the ambient density does not lie in the projection plane and the magnetic field is nearly aligned with the line of sight. So, at least a part of objects from the class may be interpreted within the framework of the considered effect. The proposed model suggests that SNRs with barrel-like radio and centrally-brightened thermal X-ray morphologies should exist. The model allows us to consider TXCs as prospective sources of proton origin gamma-rays.

  13. Multidimensional analysis of X-ray variability of AGN

    E-Print Network [OSTI]

    A. V. Halevin

    2004-09-07T23:59:59.000Z

    In this work we analyzed X-ray light curves of active galactic nucleus NGC 4051 obtained using Advanced CCD Imaging Spectrometer of Chandra satellite. Taking into account mainly flaring behaviour of AGNs we have used wavelet analysis for searching of short time lived events on light curves.

  14. Quantum coherence phenomena in x-ray optics 

    E-Print Network [OSTI]

    Anisimov, Petr Mikhailovich

    2009-05-15T23:59:59.000Z

    effects in a three-level coherently driven system. Second, we show that the interference effects may appear in X-ray radiation at the nuclear transitions under the condition of the nuclear level anti-crossing. This effects are similar...

  15. Thermal management of masks for deep x-ray lithography.

    SciTech Connect (OSTI)

    Khounsary, A.; Chojnowski, D.; Mancini, D.C.; Lai, B.; Dejus, R.

    1997-11-18T23:59:59.000Z

    This paper addresses some options and techniques in the thermal management of masks used in deep x-ray lithography. The x-ray masks are thin plates made of low-atomic-number materials on which a patterned thin film of a high-atomic-number metal has been deposited. When they are exposed to an x-ray beam, part of the radiation is transmitted to replicate the pattern on a downstream photoresist, and the remainder is absorbed in the mask in the form of heat. This heat load can cause deformation of the mask and thus image distortion in the lithography process. The mask geometry considered in the present study is 100 mm x 100 mm in area, and about 0.1 to 2 mm thick. The incident radiation is a bending magnet x-ray beam having a footprint of 60 mm x 4 mm at the mask. The mask is scanned vertically about {+-} 30 mm so that a 60 mm x 60 mm area is exposed. the maximum absorbed heat load in the mask is 80 W, which is significantly greater than a few watts encountered in previous systems. In this paper, cooling techniques, substrate material selection, transient and steady state thermal and structural behavior, and other thermo-mechanical aspects of mask design are discussed. It is shown that, while diamond and graphite remain attractive candidates, at present beryllium is a more suitable material for this purpose and, when properly cooled, can provide the necessary dimensional tolerance.

  16. DEDUCING ELECTRON PROPERTIES FROM HARD X-RAY OBSERVATIONS

    E-Print Network [OSTI]

    Piana, Michele

    of the accelerated electron distribution. Keywords: Sun: flares; Sun: X-rays; Sun: acceleration; Sun: energetic distribution 31 4.5 Low-energy cutoffs in the electron distribution 32 4.6 Temperature distribution of thermal-ray emission process(es) in question with the electron distribution function, which is in turn a function

  17. X-Ray Astronomy to Resonant Theranostics for Cancer Treatment

    E-Print Network [OSTI]

    Nahar, Sultana Nurun

    of Astronomy, The Ohio State University, Columbus, OH 43210, USA E-mail: nahar@astronomy.ohio. The falling particles spiral around the black hole, move faster close to it and release energy in the form jets at the center (Observed by X-ray space observatory Chandra). In the image: red indicates low-energy

  18. Lensless imaging of nanoporous glass with soft X-rays

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Turner, Joshua J.; Nelson, Johanna; Huang, Xiaojing; Steinbrener, Jan; Jacobsen, Chris

    2013-06-01T23:59:59.000Z

    Coherent soft X-ray diffraction has been used to image nanoporous glass structure in two dimensions using different methods. The merit of the reconstructions was judged using a new method of Fourier phase correlation with a final, refined image. The porous structure was found to have a much larger average size then previously believed.

  19. X-ray Emission from Thunderstorms and Lightning

    ScienceCinema (OSTI)

    Joseph Dwyer

    2010-01-08T23:59:59.000Z

    How lightning is initiated in the relatively low electric fields inside thunderclouds and how it can then propagate for tens of kilometers through virgin air are two of the great unsolved problems in the atmospheric sciences.  Until very recently it was believed that lightning was entirely a conventional discharge, involving only low-energy (a few eV) electrons.  This picture changed completely a few years ago with the discovery of intense x-ray emission from both natural cloud-to-ground lightning and rocket-triggered lightning.  This energetic emission cannot be produced by a conventional discharge, and so the presence of x-rays strongly implies that runaway breakdown plays a role in lightning processes.  During runaway breakdown, electrons are accelerated through air to nearly the speed of light by strong electric fields.  These runaway electrons then emit bremsstrahlung x-rays and gamma-rays during collisions with air.  Indeed, the x-ray and gamma-ray emission produced by runaway breakdown near the tops of thunderstorms is bright enough to be seen from outer space, 600 km away.  As a result, the physics used for decades to describe thunderstorm electrification and lightning discharges is incomplete and needs to be revisited. 

  20. Helium and Iron in X-ray galaxy clusters

    E-Print Network [OSTI]

    Stefano Ettori

    2006-10-16T23:59:59.000Z

    I discuss the role of the sedimentation of helium in galaxy cluster cores on the observed X-ray properties and present a history of the metal accumulation in the ICM, with new calculations with respect to my previous work following the recent evidence of a bi-modal distribution of the delay time in Supernovae Type Ia.

  1. In-situ mechanical testing during X-ray diffraction

    SciTech Connect (OSTI)

    Van Swygenhoven, Helena, E-mail: helena.vanswygenhoven@psi.ch; Van Petegem, Steven

    2013-04-15T23:59:59.000Z

    Deforming metals during recording X-ray diffraction patterns is a useful tool to get a deeper understanding of the coupling between microstructure and mechanical behaviour. With the advances in flux, detector speed and focussing techniques at synchrotron facilities, in-situ mechanical testing is now possible during powder diffraction and Laue diffraction. The basic principle is explained together with illustrative examples.

  2. Crystal defect studies using x-ray diffuse scattering

    SciTech Connect (OSTI)

    Larson, B.C.

    1980-01-01T23:59:59.000Z

    Microscopic lattice defects such as point (single atom) defects, dislocation loops, and solute precipitates are characterized by local electronic density changes at the defect sites and by distortions of the lattice structure surrounding the defects. The effect of these interruptions of the crystal lattice on the scattering of x-rays is considered in this paper, and examples are presented of the use of the diffuse scattering to study the defects. X-ray studies of self-interstitials in electron irradiated aluminum and copper are discussed in terms of the identification of the interstitial configuration. Methods for detecting the onset of point defect aggregation into dislocation loops are considered and new techniques for the determination of separate size distributions for vacancy loops and interstitial loops are presented. Direct comparisons of dislocation loop measurements by x-rays with existing electron microscopy studies of dislocation loops indicate agreement for larger size loops, but x-ray measurements report higher concentrations in the smaller loop range. Methods for distinguishing between loops and three-dimensional precipitates are discussed and possibilities for detailed studies considered. A comparison of dislocation loop size distributions obtained from integral diffuse scattering measurements with those from TEM show a discrepancy in the smaller sizes similar to that described above.

  3. Soft x-ray laser microscope. Final report

    SciTech Connect (OSTI)

    Suckewer, P.I.

    1990-10-01T23:59:59.000Z

    The program consisted of two phases (Phase I and Phase II). The goal of the Phase I (first year program) was to design and construct the Soft X-ray Laser Contact Microscope. Such microscope was constructed and adapted to PPL`s 18.2nm soft X-ray Laser (SXL), which in turn was modified and prepared for microscopy experiments. Investigation of the photoresist response to 18.2nm laser radiation and transmissivity of 0.1m thick silicion-nitride (Si{sub 3}N{sub 4}) windows were important initial works. The goal of the first year of Phase II was to construct X-ray contact microscope in combination with existing optical phase microscope, already used by biologists. In the second year of Phase II study of dehydrated Horeseshoe Crab and Hela cancer cells were performed with COXRALM. Also during Phase II, the Imaging X-Ray Laser Microscope (IXRALM) was designed and constructed. This paper describes the development of each of the microscopes and their application for research.

  4. Vanadium-pumped titanium x-ray laser

    DOE Patents [OSTI]

    Nilsen, J.

    1992-05-26T23:59:59.000Z

    A resonantly photo-pumped x-ray laser is formed of a vanadium and titanium foil combination that is driven by two beams of intense line focused optical laser radiation. Ground state neon-like titanium ions are resonantly photo-pumped by line emission from fluorine-like vanadium ions. 4 figs.

  5. Soft x-ray diagnostics for pulsed power machines

    SciTech Connect (OSTI)

    Idzorek, G.C.; Coulter, W.L.; Walsh, P.J.; Montoya, R.R.

    1995-08-01T23:59:59.000Z

    A variety of soft x-ray diagnostics are being fielded on the Los Alamos National Laboratory Pegasus and Procyon pulsed power systems and also being fielded on joint US/Russian magnetized target fusion experiments known as MAGO (Magnitoye Obzhatiye). The authors have designed a low-cost modular photoemissive detector designated the XRD-96 that uses commercial 1100 series aluminum for the photocathode. In addition to photocathode detectors a number of designs using solid state silicon photodiodes have been designed and fielded. They also present a soft x-ray time-integrated pinhole camera system that uses standard type TMAX-400 photographic film that obviates the need for expensive and no longer produced zero-overcoat soft x-ray emulsion film. In a typical experiment the desired spectral energy cuts, signal intensity levels, and desired field of view will determine diagnostic geometry and x-ray filters selected. The authors have developed several computer codes to assist in the diagnostic design process and data deconvolution. Examples of the diagnostic design process and data analysis for a typical pulsed power experiment are presented.

  6. X-rays at Solid-Liquid Surfaces

    SciTech Connect (OSTI)

    Dosch, Helmut (Max Planck Institute for Metals Research) [Max Planck Institute for Metals Research

    2007-05-02T23:59:59.000Z

    Solid-liquid interfaces play an important role in many areas of current and future technologies, and in our biosphere. They play a key role in the development of nanofluidics and nanotribology, which sensitively depend on our knowledge of the microscopic structures and phenomena at the solid-liquid interface. The detailed understanding of how a fluid meets a wall is also a theoretical challenge. In particular, the phenomena at repulsive walls are of interest, since they affect many different phenomena, such as water-repellent surfaces or the role of the hydrophobic interaction in protein folding. Recent x-ray reflectivity studies of various solid-liquid interfaces have disclosed rather intriguiing phenomena, which will be discussed in this lecture: premelting of ice in contact with silica; liquid Pb in contact with Si; water in contact with hydrophobic surfaces. These experiments, carried out with high-energy x-ray microbeams, reveal detailed insight into the liquid density profile closest to the wall. A detailed insight into atomistic phenomena at solid-liquid interfaces is also a prerequisite in the microscopic control of electrochemical reactions at interfaces. Recent x-ray studies show the enormous future potential of such non-destructive analytical tools for the in situ observation of (electro-)chemical surface reactions. This lecture will review recent x-ray experiments on solid-liquid interfaces.

  7. X-ray characterization of solid small molecule organic materials

    SciTech Connect (OSTI)

    Billinge, Simon; Shankland, Kenneth; Shankland, Norman; Florence, Alastair

    2014-06-10T23:59:59.000Z

    The present invention provides, inter alia, methods of characterizing a small molecule organic material, e.g., a drug or a drug product. This method includes subjecting the solid small molecule organic material to x-ray total scattering analysis at a short wavelength, collecting data generated thereby, and mathematically transforming the data to provide a refined set of data.

  8. Compact X-ray Light Source Workshop Report

    SciTech Connect (OSTI)

    Thevuthasan, Suntharampillai; Evans, James E.; Terminello, Louis J.; Koppenaal, David W.; Manke, Kristin L.; Plata, Charity

    2012-12-01T23:59:59.000Z

    This report, produced jointly by EMSL and FCSD, is the result of a workshop held in September 2011 that examined the utility of a compact x-ray light source (CXLS) in addressing many scientific challenges critical to advancing energy science and technology.

  9. Transient x-ray absorption spectroscopy of hydrated halogen atom

    E-Print Network [OSTI]

    Elles, Christopher G.; Shkrob, Ilya A.; Crowell, Robert A.; Arms, Dohn A.; Landahl, Eric C.

    2008-02-11T23:59:59.000Z

    Time-resolved x-ray absorption spectroscopy has been used to observe the transient species generated by one-photon detachment of an electron from aqueous bromide. The K-edge spectrum of the short-lived Br(0) atom exhibits a resonant 1s-4p transition...

  10. Simultaneous CT and SPECT tomography using CZT detectors

    DOE Patents [OSTI]

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Lubbock, TX); Simpson, Michael L. (Knoxville, TN); Britton, Jr., Charles L. (Alcoa, TN)

    2002-01-01T23:59:59.000Z

    A method for simultaneous transmission x-ray computed tomography (CT) and single photon emission tomography (SPECT) comprises the steps of: injecting a subject with a tracer compound tagged with a .gamma.-ray emitting nuclide; directing an x-ray source toward the subject; rotating the x-ray source around the subject; emitting x-rays during the rotating step; rotating a cadmium zinc telluride (CZT) two-sided detector on an opposite side of the subject from the source; simultaneously detecting the position and energy of each pulsed x-ray and each emitted .gamma.-ray captured by the CZT detector; recording data for each position and each energy of each the captured x-ray and .gamma.-ray; and, creating CT and SPECT images from the recorded data. The transmitted energy levels of the x-rays lower are biased lower than energy levels of the .gamma.-rays. The x-ray source is operated in a continuous mode. The method can be implemented at ambient temperatures.

  11. X-ray ablation measurements and modeling for ICF applications

    SciTech Connect (OSTI)

    Anderson, A.T.

    1996-09-01T23:59:59.000Z

    X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and hohlraum wall thickness are also described. Experiments have been conducted at the Nova laser on the effects of relevant x-ray fluences on various materials. The response was diagnosed using post-shot examinations of the surfaces with scanning electron microscope and atomic force microscope instruments. Judgments were made about the dominant removal mechanisms for each material. Measurements of removal depths were made to provide data for the modeling. The finite difference ablation code developed here (ABLATOR) combines the thermomechanical response of materials to x-rays with models of various removal mechanisms. The former aspect refers to energy deposition in such small characteristic depths ({approx} micron) that thermal conduction and hydrodynamic motion are significant effects on the nanosecond time scale. The material removal models use the resulting time histories of temperature and pressure-profiles, along with ancillary local conditions, to predict rates of surface vaporization and the onset of conditions that would lead to spallation.

  12. Soft X-ray spectral variability of AM Herculis

    E-Print Network [OSTI]

    K. Beuermann; E. El Kholy; K. Reinsch

    2008-02-19T23:59:59.000Z

    Polars (AM Herculis binaries) are a prominent class of bright soft X-ray sources, many of which were discovered with ROSAT. We present a homogenous analysis of all the pointed ROSAT PSPC observations of polars subdivided into two papers that discuss the prototype polar AM Her in detail and summarize the class properties of all other polars. We derive the high-state soft X-ray flux and short-term spectral variability of AM Her using a new detector response matrix and a confirmed flux calibration of the ROSAT PSPC below 0.28 keV. The best-fit mean single-blackbody temperature and integrated bright-phase energy flux of AM Her in its April 1991 high state are 27.2 +/- 1.0 eV and (2.6 +/- 0.6) x 10^-9 erg cm^-2s^-1, respectively. The total blackbody flux of a multi-temperature model that fits both the soft X-ray and the fluctuating far-ultraviolet components is Fbb = (4.5 +/- 1.5) x 10^-9 erg cm^-2s^-1. The total accretion luminosity at a distance of 80 pc, Lbb = (2.1 +/- 0.7) x 10^33 erg s-1, implies an accretion rate of Mdot = (2.4 +/- 0.8) x 10^-10 Msun yr^-1 for an 0.78 Msun white dwarf. The soft X-ray flux displays significant variability on time scales down to 200 ms. Correlated spectral and count-rate variations are seen in flares on time scales down to 1 s, demonstrating the heating and cooling associated with individual accretion events. Our spectral and temporal analysis provides direct evidence for the blobby accretion model and suggests a connection between the soft X-ray and the fluctuating far-ultraviolet components.

  13. SUPERLUMINOUS X-RAYS FROM A SUPERLUMINOUS SUPERNOVA

    SciTech Connect (OSTI)

    Levan, A. J.; Wheatley, P. J. [Department of Physics, University of Warwick, Coventry CV4 7AL (United Kingdom); Read, A. M.; Tanvir, N. R. [Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Metzger, B. D., E-mail: a.j.levan@warwick.ac.uk [Department of Physics, Columbia University, 538 West 120th Street, 704 Pupin Hall, MC 5255, New York, NY 10027 (United States)

    2013-07-10T23:59:59.000Z

    The discovery of a population of superluminous supernovae (SLSNe), with peak luminosities a factor of {approx}100 brighter than normal supernovae (SNe; typically SLSNe have M{sub V} < -21), has shown an unexpected diversity in core-collapse SN properties. Numerous models have been postulated for the nature of these events, including a strong interaction of the shockwave with a dense circumstellar environment, a re-energizing of the outflow via a central engine, or an origin in the catastrophic destruction of the star following a loss of pressure due to pair production in an extremely massive stellar core (so-called pair instability SNe). Here we consider constraints that can be placed on the explosion mechanism of hydrogen-poor SLSNe (SLSNe-I) via X-ray observations, with XMM-Newton, Chandra, and Swift, and show that at least one SLSN-I is likely the brightest X-ray SN ever observed, with L{sub X} {approx} 10{sup 45} erg s{sup -1}, {approx}150 days after its initial discovery. This is a luminosity three orders of magnitude higher than seen in other X-ray SNe powered via circumstellar interactions. Such high X-ray luminosities are sufficient to ionize the ejecta and markedly reduce the optical depth, making it possible to see deep into the ejecta and any source of emission that resides there. Alternatively, an engine could have powered a moderately relativistic jet external to the ejecta, similar to those seen in gamma-ray bursts. If the detection of X-rays does require an engine it implies that these SNe do create compact objects, and that the stars are not completely destroyed in a pair instability event. Future observations will determine which, if any, of these mechanisms are at play in SLSNe.

  14. GAMMA-RAY VARIABILITY FROM WIND CLUMPING IN HIGH-MASS X-RAY BINARIES This article has been downloaded from IOPscience. Please scroll down to see the full text article.

    E-Print Network [OSTI]

    Townsend, Richard

    the resulting gamma-ray emissivity depends on the target density, the detection of rapid variabilityGAMMA-RAY VARIABILITY FROM WIND CLUMPING IN HIGH-MASS X-RAY BINARIES WITH JETS This article has Society. All rights reserved. Printed in the U.S.A. GAMMA-RAY VARIABILITY FROM WIND CLUMPING IN HIGH

  15. X-ray absorption spectroscopy by full-field X-ray microscopy of a thin graphite flake: Imaging and

    E-Print Network [OSTI]

    Hitchcock, Adam P.

    .bittencourt@ua.ac.be * Corresponding author Keywords: carbon; graphene; nanostructure; NEXAFS; X-ray microscopy Beilstein J structure of graphite flakes consisting of a few graphene layers. The flake was produced by exfoli- ation of the remarkable transport properties of graphene in 2004 by Geim and Novoselov triggered intense interest in its

  16. X-ray source system at the MSFC x-ray calibration facility J. J. Kolodziejczak, R. A. Austin

    E-Print Network [OSTI]

    Wargelin, Bradford J.

    hyperbolic shells, which combine to form AXAF's Wolter-I High-resolution mirror assembly (HRMA), is a phase. A part of this time will be devoted exclusively to x-ray characterization of the HRMA using a set of instruments developed by personnel at the Smithsonian Astrophysical Observatory (SAO) called the HRMA X

  17. X-ray crystal structure and small-angle X-ray scattering of sheep liver sorbitol dehydrogenase

    SciTech Connect (OSTI)

    Yennawar, Hemant [Pennsylvania State University, 8 Althouse Laboratory, University Park, PA 16802 (United States); Mřller, Magda [Cornell High Energy Synchrotron Source, Ithaca, NY 14853 (United States); University of Copenhagen, DK-2100 Copenhagen (Denmark); Gillilan, Richard [Cornell High Energy Synchrotron Source, Ithaca, NY 14853 (United States); Yennawar, Neela, E-mail: nhy1@psu.edu [Pennsylvania State University, 8 Althouse Laboratory, University Park, PA 16802 (United States)

    2011-05-01T23:59:59.000Z

    The X-ray crystal structure and a small-angle X-ray scattering solution structure of sheep liver sorbitol dehydrogenase have been determined. The details of the interactions that enable the tetramer scaffold to be the functional biological unit have been analyzed. The X-ray crystal structure of sheep liver sorbitol dehydrogenase (slSDH) has been determined using the crystal structure of human sorbitol dehydrogenase (hSDH) as a molecular-replacement model. slSDH crystallized in space group I222 with one monomer in the asymmetric unit. A conserved tetramer that superposes well with that seen in hSDH (despite belonging to a different space group) and obeying the 222 crystal symmetry is seen in slSDH. An acetate molecule is bound in the active site, coordinating to the active-site zinc through a water molecule. Glycerol, a substrate of slSDH, also occupies the substrate-binding pocket together with the acetate designed by nature to fit large polyol substrates. The substrate-binding pocket is seen to be in close proximity to the tetramer interface, which explains the need for the structural integrity of the tetramer for enzyme activity. Small-angle X-ray scattering was also used to identify the quaternary structure of the tetramer of slSDH in solution.

  18. Distribution of unresolvable anisotropic microstructures revealed in visibility-contrast images using x-ray Talbot interferometry

    SciTech Connect (OSTI)

    Yashiro, Wataru; Harasse, Sebastien; Kawabata, Katsuyuki; Kuwabara, Hiroaki; Yamazaki, Takashi; Momose, Atsushi [Department of Advanced Materials Science, Graduate School of Frontier Sciences, the University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan)

    2011-09-01T23:59:59.000Z

    X-ray Talbot interferometry has been widely used as a technique for x-ray phase imaging and tomography. We propose a method using this interferometry for mapping distribution of parameters characterizing anisotropic microstructures, which are typically of the order of {mu}m in size and cannot be resolved by the imaging system, in a sample. The method uses reduction in fringe visibility, which is caused by such unresolvable microstructures, in moire images obtained using an interferometer. We applied the method to a chloroprene rubber sponge sample, which exhibited uniaxial anisotropy of reduced visibility. We measured the dependencies of reduced visibility on both the Talbot order and the orientation of the sample and obtained maps of three parameters and their anisotropies that characterize the unresolvable anisotropic microstructures in the sample. The maps indicated that the anisotropy of the sample's visibility contrast mainly originated from the anisotropy of the microstructure elements' average size. Our method directly provides structural information on unresolvable microstructures in real space, which is only accessible through the ultra-small-angle x-ray scattering measurements in reciprocal space, and is expected to be broadly applied to material, biological, and medical sciences.

  19. Beam damage of poly(vinyl chloride) [PVC] as observed by x-ray...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    damage of poly(vinyl chloride) PVC as observed by x-ray photoelectron spectroscopy at 143 K, 303 K and 373 K. Beam damage of poly(vinyl chloride) PVC as observed by x-ray...

  20. Non-Destructive X-ray Measurement of Soot, Ash, Washcoat and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    X-ray Measurement of Soot, Ash, Washcoat and Regeneration Damage for DPFs Non-Destructive X-ray Measurement of Soot, Ash, Washcoat and Regeneration Damage for DPFs New commercially...

  1. Simple Method for Estimating and Comparing of X-Ray Damage Rates...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Method for Estimating and Comparing of X-Ray Damage Rates. Simple Method for Estimating and Comparing of X-Ray Damage Rates. Abstract: This note describes an approach for...

  2. The ALS X-Ray Streak Camera: Bringing the Ultrafast and Ultrasmall...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ultrafast is at the frontier of scientific research. Two x-ray approaches can be used for ultrafast examinations. The first entails developing sources that have short x-ray pulses...

  3. Development of procedures for refurbishing x-ray optics at the Advanced Light Source

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2013-01-01T23:59:59.000Z

    and Setting of Bendable Optics for Diffraction- Limitedof Soft X-Rays,” Abstract to SPIE Optics and Photonics 2012,Metrology for X-Ray and EUV Optics IV (San Diego, August 12-

  4. A New Analysis of X-Ray Adsorption Branching Ratios: Use ofRussell...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Analysis of X-Ray Adsorption Branching Ratios: Use of Russell-Saunders Coupling . A New Analysis of X-Ray Adsorption Branching Ratios: Use of Russell-Saunders Coupling . Abstract:...

  5. Ultra-high Resolution Optics for EUV and Soft X-ray Inelastic Scattering

    E-Print Network [OSTI]

    Voronov, Dmitry L.

    2010-01-01T23:59:59.000Z

    16. Yu. Shvyd’ko, X-Ray Optics, Berlin: Springer-Verlag,Ultra-high Resolution Optics for EUV and Soft X-rayspectral resolution soft x-ray optics. Conventionally in the

  6. Advanced X-ray Optics Metrology for Nanofocusing and Coherence Preservation

    E-Print Network [OSTI]

    Goldberg, Kenneth A.

    2008-01-01T23:59:59.000Z

    workshop: “Advanced X-Ray Optics Metrology for Nano-focusinglight sources if beamline optics won’t be available toTitled, “Advanced X-Ray Optics Metrology for Nano-focusing

  7. Automated suppression of errors in LTP-II slope measurements with x-ray optics

    E-Print Network [OSTI]

    Ali, Zulfiqar

    2012-01-01T23:59:59.000Z

    precise reflective X-ray optics,” Nucl. Instrum. and Methods70 (2001). [2] P. Z. Takacs, “X- ray optics metrology,” in [Handbook of Optics], 3rd ed. , Vol. V, M. Bass, Ed. ,

  8. Bendable X-ray Optics at the ALS: Design, Tuning, Performance and Applications

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.; Advanced Light Source, Lawrence Berkeley National Laboratory

    2008-01-01T23:59:59.000Z

    BENDABLE X-RAY OPTICS AT THE ALS: DESIGN, TUNING,ALS) of bendable x- ray optics widely used for focusing ofAn example of a bendable optic used at ALS beamline 5.0.2.

  9. Development of at-wavelength metrology for x-ray optics at the ALS

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2010-01-01T23:59:59.000Z

    alignment of bendable x-ray optics to realize diffraction-Bass (Ed. ), Handbook of Optics, third ed. , vol. V, ch. 46,wavelength metrology for x-ray optics at the ALS* Valeriy V.

  10. SciTech Connect: White and Monochromatic X-ray Microbeam Investigation...

    Office of Scientific and Technical Information (OSTI)

    White and Monochromatic X-ray Microbeam Investigations of Materials Microstructure and Tri-Axial Stress Citation Details In-Document Search Title: White and Monochromatic X-ray...

  11. Advanced Research in Diesel Fuel Sprays Using X-rays from the...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Research in Diesel Fuel Sprays Using X-rays from the Advanced Photon Source Advanced Research in Diesel Fuel Sprays Using X-rays from the Advanced Photon Source 2003 DEER...

  12. Lithium fluoride (LiF) crystal for parametric X-ray (PXR) production

    E-Print Network [OSTI]

    Danon, Yaron

    Lithium fluoride (LiF) crystal for parametric X-ray (PXR) production B. Sones *, Y. Danon, R 2004 Abstract Parametric X-ray (PXR) production is reported using lithium fluoride (LiF) as a target

  13. Studies of a Linac Driver for a High Repetition Rate X-Ray FEL

    E-Print Network [OSTI]

    Venturini, M.

    2012-01-01T23:59:59.000Z

    REPETITION RATE X-RAY FEL ? M. Venturini † , J. Corlett, L.support a high repetition rate FEL operating in the soft x-of high-repetition rate FEL machine generat- ing soft x-rays

  14. Technique for the Generation of Attosecond X-Ray Pulses Using an FEL

    E-Print Network [OSTI]

    Penn, G.; Zholents, A.A.

    2005-01-01T23:59:59.000Z

    experiments at a X-ray SASE FEL”, Optics Communications,considerations for a SASE X-ray FEL”, Nucl. Instr. Methodsa fully 3D time-dependent FEL simulation code”, Nucl. Instr.

  15. Ion implantation for figure correction of high-resolution x-ray telescope mirrors

    E-Print Network [OSTI]

    Chalifoux, Brandon D

    2014-01-01T23:59:59.000Z

    Fabricating mirrors for future high-resolution, large-aperture x-ray telescopes continues to challenge the x-ray astronomy instrumentation community. Building a large-aperture telescope requires thin, lightweight mirrors; ...

  16. Design and development of a 3D X-ray microscope

    E-Print Network [OSTI]

    Brayanov, Jordan, 1981-

    2006-01-01T23:59:59.000Z

    The rapid development of needle-free injection systems demands better and faster imaging systems, capable of imaging the transient and steady state response of an injection into real tissue. X-ray radiography, x-ray ...

  17. Simulating Ru L3-edge X-ray Absorption Spectroscopy with Time...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Ru L3-edge X-ray Absorption Spectroscopy with Time-Dependent Density Functional Theory: Model Complexes and Electron Simulating Ru L3-edge X-ray Absorption Spectroscopy with...

  18. High-Resolution Computed Tomography Study of the Cranium of

    E-Print Network [OSTI]

    Allman, John M.

    High-Resolution Computed Tomography Study of the Cranium of a Fossil Anthropoid Primate of these characteristics may have important implications for brain evolution. Here computed tomography is used to examine in the evolutionary development of anthropoids did these characteristics evolve? We recently used X-ray computed

  19. Fiber fed x-ray/gamma ray imaging apparatus

    DOE Patents [OSTI]

    Hailey, C.J.; Ziock, K.P.

    1992-06-02T23:59:59.000Z

    X-ray/gamma ray imaging apparatus is disclosed for detecting the position, energy, and intensity of x-ray/gamma ray radiation comprising scintillation means disposed in the path of such radiation and capable of generating photons in response to such radiation; first photodetection means optically bonded to the scintillation means and capable of generating an electrical signal indicative of the intensity, and energy of the radiation detected by the scintillation means; second photodetection means capable of generating an electrical signal indicative of the position of the radiation in the radiation pattern; and means for optically coupling the scintillation means to the second photodetection means. The photodetection means are electrically connected to control and storage means which may also be used to screen out noise by rejecting a signal from one photodetection means not synchronized to a signal from the other photodetection means; and also to screen out signals from scattered radiation. 6 figs.

  20. LCLS - The X-ray Laser Has Turned On

    SciTech Connect (OSTI)

    Bergmann, Uwe (Linac Coherent Light Source) [Linac Coherent Light Source

    2010-11-03T23:59:59.000Z

    On April 10, 2009 the Linac Coherent Light Source (LCLS), the world's first hard x-ray free electron laser, was brought to lasing. Producing an x-ray beam with over a billion times higher peak brightness that then most powerful existing syncrotron sources, it marked the beginning of a new era of science. The LCLS pulses arrive at a rate of 60 - 120 Hz in an energy range from 480 eV to 10 keV, with pulse lengths as short as a few fs to about 300 fs. Since October 2009, users have been performing experiments at the LCLS, and currently three of the six planned instruments are available. Although we stand only at the beginning of LCLS science, there is no doubt about the strong sense of early excitement.

  1. A New Measurement of Kaonic Hydrogen X rays

    E-Print Network [OSTI]

    M. Bazzi; G. Beer; L. Bombelli; A. M. Bragadireanu; M. Cargnelli; G. Corradi; C. Curceanu; A. d'Uffizi; C. Fiorini; T. Frizzi; F. Ghio; B. Girolami; C. Guaraldo; R. S. Hayano; M. Iliescu; T. Ishiwatari; M. Iwasaki; P. Kienle; P. Levi Sandri; A. Longoni; V. Lucherini; J. Marton; S. Okada; D. Pietreanu; T. Ponta; A. Rizzo; A. Romero Vidal; A. Scordo; H. Shi; D. L. Sirghi; F. Sirghi; H. Tatsuno; A. Tudorache; V. Tudorache; O. Vazquez Doce; E. Widmann; J. Zmeskal

    2011-08-09T23:59:59.000Z

    The $\\bar{K}N$ system at threshold is a sensitive testing ground for low energy QCD, especially for the explicit chiral symmetry breaking. Therefore, we have measured the $K$-series x rays of kaonic hydrogen atoms at the DA$\\Phi$NE electron-positron collider of Laboratori Nazionali di Frascati, and have determined the most precise values of the strong-interaction energy-level shift and width of the $1s$ atomic state. As x-ray detectors, we used large-area silicon drift detectors having excellent energy and timing resolution, which were developed especially for the SIDDHARTA experiment. The shift and width were determined to be $\\epsilon_{1s} = -283 \\pm 36 \\pm 6 {(syst)}$ eV and $\\Gamma_{1s} = 541 \\pm 89 {(stat)} \\pm 22 {(syst)}$ eV, respectively. The new values will provide vital constraints on the theoretical description of the low-energy $\\bar{K}N$ interaction.

  2. Superluminous X-rays from a superluminous supernova

    E-Print Network [OSTI]

    Levan, A J; Metzger, B D; Wheatley, P J; Tanvir, N R

    2013-01-01T23:59:59.000Z

    The discovery of a population of superluminous supernovae (SLSNe), with peak luminosities a factor of ~100 brighter than normal SNe (typically SLSNe have M_V engine, or an origin in the catastrophic destruction of the star following a loss of pressure due to pair production in an extremely massive stellar core (so-called pair instability supernovae). Here we consider constraints that can be placed on the explosion mechanism of Hydrogen-poor SLSNe (SLSNe-I) via X-ray observations, with XMM-Newton, Chandra and Swift, and show that at least one SLSNe-I is likely the brightest X-ray supernovae ever observed, with L_X ~ 10^45 ergs/s, ~150 days after its initial discovery. This is a luminosity 3 orders of magnitude higher than seen in ...

  3. Segmentation of x-ray images using Probabilistic Relaxation Labeling

    SciTech Connect (OSTI)

    Thai, T.Q.

    1991-01-01T23:59:59.000Z

    Segmentation is a process of separating objects of interest from their background or from other objects in an image. Without a suitable segmentation scheme, it is very difficult to detect contraband in X-rays images. In this paper, a Probabilistic Relaxation Labeling (PRL) segmentation scheme is presented and compared with other segmentation methods. PRL segmentation is an interative algorithm that labels each pixel in an image by cooperative use of two information sources: the pixel probability and the degree of certainty of its probability supported by the neighboring pixels. The practical implementation and results of the PRL segmentation on X-ray baggage images are also discussed and compared with other segmentation methods. 13 refs., 12 figs.

  4. Rotational Doppler effect in x-ray photoionization

    SciTech Connect (OSTI)

    Sun Yuping; Wang Chuankui [College of Physics and Electronics, Shandong Normal University, 250014 Jinan (China); Theoretical Chemistry, Roslagstullsbacken 15, Royal Institute of Technology, S-106 91 Stockholm (Sweden); Gel'mukhanov, Faris [Theoretical Chemistry, Roslagstullsbacken 15, Royal Institute of Technology, S-106 91 Stockholm (Sweden)

    2010-11-15T23:59:59.000Z

    The energy of the photoelectron experiences a red or blue Doppler shift when the molecule recedes from the detector or approaches him. This results in a broadening of the photoelectron line due to the translational thermal motion. However, the molecules also have rotational degrees of freedom and we show that the translational Doppler effect has its rotational counterpart. This rotational Doppler effect leads to an additional broadening of the spectral line of the same magnitude as the Doppler broadening caused by translational thermal motion. The rotational Doppler broadening as well as the rotational recoil broadening is sensitive to the molecular orbital from which the photoelectron is ejected. This broadening should be taken into account in analysis of x-ray photoemission spectra of super-high resolution and it can be directly observed using x-ray pump-probe spectroscopy.

  5. Phase Effects on Mesoscale Object X-ray Absorption Images

    SciTech Connect (OSTI)

    Martz, Jr., H E; Aufderheide, M B; Barty, A; Lehman, S K; Kozioziemski, B J; Schneberk, D J

    2004-09-24T23:59:59.000Z

    At Lawrence Livermore National Laboratory particular emphasis is being placed on the nondestructive characterization (NDC) of 'mesoscale' objects.[Martz and Albrecht 2003] We define mesoscale objects as objects that have mm extent with {micro}m features. Here we confine our discussions to x-ray imaging methods applicable to mesoscale object characterization. The goal is object recovery algorithms including phase to enable emerging high-spatial resolution x-ray imaging methods to ''see'' inside or image mesoscale-size materials and objects. To be successful our imaging characterization effort must be able to recover the object function to one micrometer or better spatial resolution over a few millimeters field-of-view with very high contrast.

  6. Background-reducing X-ray multilayer mirror

    DOE Patents [OSTI]

    Bloch, Jeffrey J. (Los Alamos, NM); Roussel-Dupre', Diane (Los Alamos, NM); Smith, Barham W. (Los Alamos, NM)

    1992-01-01T23:59:59.000Z

    Background-reducing x-ray multilayer mirror. A multiple-layer "wavetrap" deposited over the surface of a layered, synthetic-microstructure soft x-ray mirror optimized for reflectivity at chosen wavelengths is disclosed for reducing the reflectivity of undesired, longer wavelength incident radiation incident thereon. In three separate mirror designs employing an alternating molybdenum and silicon layered, mirrored structure overlaid by two layers of a molybdenum/silicon pair anti-reflection coating, reflectivities of near normal incidence 133, 171, and 186 .ANG. wavelengths have been optimized, while that at 304 .ANG. has been minimized. The optimization process involves the choice of materials, the composition of the layer/pairs as well as the number thereof, and the distance therebetween for the mirror, and the simultaneous choice of materials, the composition of the layer/pairs, and their number and distance for the "wavetrap."

  7. Single photon energy dispersive x-ray diffraction

    SciTech Connect (OSTI)

    Higginbotham, Andrew; Patel, Shamim; Ciricosta, Orlando; Suggit, Matthew J.; Wark, Justin S. [Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford OX1 3PU (United Kingdom)] [Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford OX1 3PU (United Kingdom); Hawreliak, James A.; Collins, Gilbert W.; Coppari, Federica; Eggert, Jon H. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States)] [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Tang, Henry [Department of Earth and Planetary Science, University of California Berkeley, Berkeley, California 94720 (United States)] [Department of Earth and Planetary Science, University of California Berkeley, Berkeley, California 94720 (United States)

    2014-03-15T23:59:59.000Z

    With the pressure range accessible to laser driven compression experiments on solid material rising rapidly, new challenges in the diagnosis of samples in harsh laser environments are emerging. When driving to TPa pressures (conditions highly relevant to planetary interiors), traditional x-ray diffraction techniques are plagued by increased sources of background and noise, as well as a potential reduction in signal. In this paper we present a new diffraction diagnostic designed to record x-ray diffraction in low signal-to-noise environments. By utilising single photon counting techniques we demonstrate the ability to record diffraction patterns on nanosecond timescales, and subsequently separate, photon-by-photon, signal from background. In doing this, we mitigate many of the issues surrounding the use of high intensity lasers to drive samples to extremes of pressure, allowing for structural information to be obtained in a regime which is currently largely unexplored.

  8. Relativistic Effects on Reflection X-ray Spectra of AGN

    SciTech Connect (OSTI)

    Lee, Khee-Gan; /University Coll. London; Fuerst, Steven V.; /KIPAC, Menlo Park; Brandwardi-Raymond, Graziella; Wu, Kinwah; Crowley, Oliver; /University Coll. London

    2007-01-05T23:59:59.000Z

    We have calculated the reflection component of the X-ray spectra of active galactic nuclei (AGN) and shown that they can be significantly modified by the relativistic motion of the accretion flow and various gravitational effects of the central black hole. The absorption edges in the reflection spectra suffer severe energy shifts and smearing. The degree of distortion depends on the system parameters, and the dependence is stronger for some parameters such as the inner radius of the accretion disk and the disk viewing inclination angles. The relativistic effects are significant and are observable. Improper treatment of the reflection component of the X-ray continuum in spectral fittings will give rise to spurious line-like features, which will mimic the fluorescent emission lines and mask the relativistic signatures of the lines.

  9. Thermal X-ray emission of the remnants of ashperical Supernova explosions

    E-Print Network [OSTI]

    O. Petruk

    2001-03-26T23:59:59.000Z

    Evolution of adiabatic remnants of an aspherical supernova explosion in uniform medium are considered. Thermal X-ray emission of such remnants are investigated. It is shown that integral thermal X-ray characteristics (X-ray luminosity and spectrum) of the objects do not allow us to reveal the assymetry in the explosion because these characteristics are close to their Sedov counterparts. Surface distribution of X-ray emission is sensitive to anisotropy of the explosion and nonuniformity of the interstellar medium.

  10. A grazing incidence x-ray streak camera for ultrafast, single-shot measurements

    E-Print Network [OSTI]

    Feng, Jun

    2010-01-01T23:59:59.000Z

    provided by UV pulses derived from an ultrafast laser. Dueultrafast dynamics using a single synchrotron x-ray pulse.

  11. Scanning Transmission X-ray Microscopy: Applications in Atmospheric Aerosol Research

    E-Print Network [OSTI]

    Moffet, Ryan C.

    2011-01-01T23:59:59.000Z

    X-ray microscope at BESSY II. Journal of SynchrotronSaskatoon, Canada), 11 BESSY II (Berlin, Germany), 12 Swiss

  12. Final report: high resolution lensless 3D imaging of nanostructures with coherent x-rays

    SciTech Connect (OSTI)

    Jacobsen, Chris

    2014-12-07T23:59:59.000Z

    Final report on the project "High resolution lensless 3D imaging of nanostructures with coherent x-rays"

  13. Attenuation of high-energy x rays by iron shielding

    SciTech Connect (OSTI)

    Bespalov, V.I.; Chakhlov, V.L.; Shtein, M.M.

    1988-04-01T23:59:59.000Z

    Monte Carlo calculations are presented on electron-accelerator x-ray spectra for actual target thicknesses and electron energies of 4-50 MeV. Effective attenuation coefficients have been obtained as well as build-up factors for collimated beams andiron shielding of thickness form 1 to 80 cm. The radiation contrast has been determined as a function of thickness for this energy range.

  14. A laser triggered vacuum spark x-ray lithography source 

    E-Print Network [OSTI]

    Keating, Richard Allen

    1987-01-01T23:59:59.000Z

    was 50 cm. Obviously, this type of configurat, ion is totally impractical for a step and repeat system. Synchrotron radiation is being considered as an x-ray lithography source. Many laboratories are experi- menting with synchrotron sources. Also... for production of submicron geometries and improvements needed is presented. 1v ACKNOWLEDGMENT This thesis was made possible through the assistance of a number of people. Huang Wei Ling helped gather much of the data presented in this thesis. She also...

  15. The Soft X-ray Spectromicroscopy Beamline at SSRF

    SciTech Connect (OSTI)

    Guo, Z.; Tai, R.; Wand, Y.; Yan, R.; Chen, M.; Wu, Y.; Chen, J.; Xue, S.; Xu, H. [Shanghai Synchrotron Radiation Facility, Shanghai Institute of Appled Physics, CAS 239 Zhang Heng Road, Pudong District, Shanghai (China)

    2011-09-09T23:59:59.000Z

    Commissioning of the soft x-ray spectromicroscopy beanmline at SSRF was formally started on Dec 26, 2008. Beamline performance has reached or surpassed the designing goals according to the measurements by domestic experts, especially for its high energy resolution and high spatial resolution. Since its first operation by users on May 6, 2009, tens of experiments have been conducted, and some preliminary exciting results have been acquired.

  16. Generating X-ray lines from annihilating dark matter

    E-Print Network [OSTI]

    Emilian Dudas; Lucien Heurtier; Yann Mambrini

    2014-05-08T23:59:59.000Z

    We propose different scenarios where a keV dark matter annihilates to produce a monochromatic signal. The process is generated through the exchange of a light scalar of mass of order 300 keV - 50 MeV coupling to photon through loops or higher dimensional operators. For natural values of the couplings and scales, the model can generate a gamma-ray line which can fit with the recently identified 3.5 keV X-ray line.

  17. Calibrations of a multichannel soft x-ray spectrometer

    SciTech Connect (OSTI)

    Blake, R.L.; Hockaday, R.G.; Grosso, J.S.

    1986-01-01T23:59:59.000Z

    A time resolved, 14 channel spectrometer with an absolutely calibrated response, was developed to cove an x-ray photon energy spectrum from 70 to 650 eV. The spectrometer utilized a combination of thin film prefilters, layered synthetic microstructure (LSM) diffractors, metal coated plastic scintillators, and photomultiplier detector tubes. Calibration of the spectrometer was done piecemeal for each component with standard techniques and the component calibrations were convolved to get a complete spectrometer response function. The two calibration procedures were compared.

  18. 18. Ultrasonic Computed Tomography Philippe Lasaygues, Rgine Guillermin, Jean-Pierre Lefebvre

    E-Print Network [OSTI]

    Boyer, Edmond

    18. Ultrasonic Computed Tomography Philippe Lasaygues, Régine Guillermin, Jean-Pierre Lefebvre ­ France Abstract: Ultrasonic Computed Tomography (UCT) is a full digital imaging technique, which consists, or the acoustical impedance of the medium. Ultrasonic Computed Tomography (UCT), which combines X-ray Computed

  19. Flat-response x-ray-diode-detector development

    SciTech Connect (OSTI)

    Tirsell, G.

    1982-10-01T23:59:59.000Z

    In this report we discuss the design of an improved sub-nanosecond flat response x-ray diode detector needed for ICF diagnostics. This device consists of a high Z cathode and a complex filter tailored to flatten the response so that the total x-ray energy below 1.5 keV can be measured using a single detector. Three major problems have become evident as a result of our work with the original LLNL design including deviation from flatness due to a peak in the response below 200 eV, saturation at relatively low x-ray fluences, and long term gold cathode instability. We are investigating grazing incidence reflection to reduce the response below 200 eV, new high Z cathode materials for long term stability, and a new complex filter for improved flatness. Better saturation performance will require a modified XRD detector under development with reduced anode to cathode spacing and increased anode bias voltage.

  20. X-ray Synchrotron Radiation in a Plasma Wiggler

    SciTech Connect (OSTI)

    Wang, Shuoquin; /UCLA /SLAC, SSRL

    2005-09-27T23:59:59.000Z

    A relativistic electron beam can radiate due to its betatron motion inside an ion channel. The ion channel is induced by the electron bunch as it propagates through an underdense plasma. In the theory section of this thesis the formation of the ion channel, the trajectories of beam electrons inside the ion channel, the radiation power and the radiation spectrum of the spontaneous emission are studied. The comparison between different plasma wiggler schemes is made. The difficulties in realizing stimulated emission as the beam traverses the ion channel are investigated, with particular emphasis on the bunching mechanism, which is important for the ion channel free electron laser. This thesis reports an experiment conducted at the Stanford Linear Accelerator Center (SLAC) to measure the betatron X-ray radiations for the first time. They first describe the construction and characterization of the lithium plasma source. In the experiment, the transverse oscillations of the SLAC 28.5 GeV electron beam traversing through a 1.4 meter long lithium plasma source are clearly seen. These oscillations lead to a quadratic density dependence of the spontaneously emitted betatron X-ray radiation. The divergence angle of the X-ray radiation is measured. The absolute photon yield and the spectral brightness at 14.2 KeV photon energy are estimated and seen to be in reasonable agreement with theory.

  1. Soft X-ray Pulsations in Solar Flares

    E-Print Network [OSTI]

    Simőes, Paulo J A; Fletcher, Lyndsay

    2014-01-01T23:59:59.000Z

    The soft X-ray emissions of solar flares come mainly from the bright coronal loops at the highest temperatures normally achieved in the flare process. Their ubiquity has led to their use as a standard measure of flare occurrence and energy, although the bulk of the total flare energy goes elsewhere. Recently Dolla et al. (2012) noted quasi-periodic pulsations (QPP) in the soft X-ray signature of the X-class flare SOL2011-02-15, as observed by the standard photometric data from the GOES (Geostationary Operational Environmental Satellite) spacecraft. We analyze the suitability of the GOES data for this kind of analysis and find them to be generally valuable after Sept. 2010 (GOES-15). We then extend Dolla et al. results to a list of X-class flares from Cycle 24, and show that most of them display QPP in the impulsive phase. During the impulsive phase the footpoints of the newly-forming flare loops may also contribute to the observed soft X-ray variations. The QPP show up cleanly in both channels of the GOES dat...

  2. THz Pump and X-Ray Probe Development at LCLS

    SciTech Connect (OSTI)

    Fisher, Alan S; /SLAC, LCLS; Durr, Hermann; /SIMES, Stanford /SLAC, PULSE; Lindenberg, Aaron; Stanford U., Materials Sci.Dept.; /SIMES, Stanford /SLAC, PULSE; Reis, David; /SIMES, Stanford /SLAC, PULSE /Stanford U., Dept. Appl. Phys.; Frisch, Josef; Loos, Henrik; Petree, Mark; /SLAC, LCLS; Daranciang, Dan; /Stanford U., Chem. Dept.; Fuchs, Matthias; /SLAC, PULSE; Ghimire, Shambhu; /SLAC, PULSE; Goodfellow, John; /Stanford U., Materials Sci. Dept.

    2011-11-08T23:59:59.000Z

    We report on measurements of broadband, intense, coherent transition radiation at terahertz frequencies, generated as the highly compressed electron bunches in Linear Coherent Light Source (LCLS) pass through a thin metal foil. The foil is inserted at 45{sup o} to the electron beam, 31 m downstream of the undulator. The THz emission passes downward through a diamond window to an optical table below the beamline. A fully compressed 350-pC bunch produces up to 0.5 mJ in a nearly half-cycle pulse of 50 fs FWHM with a spectrum peaking at 10 THz. We estimate a peak field at the focus of over 2.5 GV/m. A 20-fs Ti:sapphire laser oscillator has recently been installed for electro-optic measurements. We are developing plans to add an x-ray probe to this THz pump, by diffracting FEL x rays onto the table with a thin silicon crystal. The x rays would arrive with an adjustable time delay after the THz. This will provide a rapid start to user studies of materials excited by intense single-cycle pulses and will serve as a step toward a THz transport line for LCLS-II.

  3. X-ray Lenses Fabricated by LIGA Technology

    SciTech Connect (OSTI)

    Nazmov, Vladimir; Last, Arndt; Saile, Volker [Institut fuer Microstrukturtechnik, Forschungszentrum Karlsruhe GmbH, 76021 Karlsruhe (Germany); Karlsruhe University, 76131 Karlsruhe (Germany); Reznikova, Elena; Mohr, Jurgen [Institut fuer Microstrukturtechnik, Forschungszentrum Karlsruhe GmbH, 76021 Karlsruhe (Germany); Simon, Rolf [Institut fuer Synchrotronstrahlung, Forschungszentrum Karlsruhe GmbH, 76021 Karlsruhe (Germany); DiMichiel, Marco [European Synchrotron Radiation Facility, BP220, 38043, Grenoble (France)

    2007-01-19T23:59:59.000Z

    X-ray refractive optical lens systems have been successfully elaborated, designed, fabricated at the Institute for Microstructure Technology at the Forschungszentrum Karlsruhe (Germany) using LIGA technology in recent years. The lenses are structured in a SU-8 polymer. The capability of the LIGA technique to create an arbitrary profile of the focusing microstructures allow the fabrication of lenses with different curvature radius of parabolic geometry, minimized absorption and a large depth of focus. Also a set of planar lens systems on one substrate can be realized with 17 lenses providing identical focal distances for different X-ray energies from 2 to over 100 keV. Nickel lenses fabricated by electroforming using polymer templates can be applied for energies larger than 80 keV. The parabolic crossed lenses are used for 2D nano focusing of monochromatic beams. The quasi-parabolic crossed lenses with a submicron focus and a focus depth of the centimetre range can be used as an achromatic system. Mosaic truncated parabolic lenses with a focusing aperture up to 1 mm are made to increase the X-ray intensity in the focused spot.

  4. Soft X-ray emission in flaring coronal loops

    E-Print Network [OSTI]

    Pinto, R F; Brun, A S

    2014-01-01T23:59:59.000Z

    Solar flares are associated with intense soft X-ray emission generated by the hot flaring plasma in coronal magnetic loops. Kink unstable twisted flux-ropes provide a source of magnetic energy which can be released impulsively and account for the heating of the plasma in flares. We investigate the temporal, spectral and spatial evolution of the properties of the thermal X-ray emission produced in such kink-unstable magnetic flux-ropes using a series of MHD simulations. We deduce emission diagnostics and their temporal evolution and discuss the results of the simulations with respect to observations. The numerical setup used consists of a highly twisted loop embedded in a region of uniform and untwisted background coronal magnetic field. We let the kink instability develop, compute the evolution of the plasma properties in the loop (density, temperature) and deduce the X-ray emission properties of the plasma during the whole flaring episode. During the initial phase of the instability plasma heating is mostly ...

  5. Ultrafast extended x-ray absorption fine structure ,,EXAFS...--theoretical considerations

    E-Print Network [OSTI]

    Cao, Jianshu

    13­20 to generate ultrafast x-ray pulses, however, the prospect of ultrafast EXAFS seems encouragingUltrafast extended x-ray absorption fine structure ,,EXAFS...--theoretical considerations Frank L by the recent experimental demonstration of ultrafast x-ray absorption spectroscopy, we present a framework

  6. X-ray timing of the accreting millisecond pulsar SAX J1808.4-3658

    E-Print Network [OSTI]

    Hartman, Jacob M., Ph. D. Massachusetts Institute of Technology

    2007-01-01T23:59:59.000Z

    We present a 7 yr timing study of the 2.5 ms X-ray pulsar SAX J1808.4-3658, an X-ray transient with a recurrence time of =2 yr, using data from the Rossi X-ray Timing Explorer covering 4 transient outbursts (1998-2005). ...

  7. National School on Neutron and X-ray Scattering August 10-24, 2013

    E-Print Network [OSTI]

    Kemner, Ken

    National School on Neutron and X-ray Scattering August 10-24, 2013 Argonne National Laboratory National Laboratory 3:15 ­ 3:30 Break #12;National School on Neutron and X-ray Scattering August 10 Dinner Week 1 wrap-up Picnic #12;National School on Neutron and X-ray Scattering August 10-24, 2012 Oak

  8. National School on Neutron and X-ray Scattering June 14-28, 2014

    E-Print Network [OSTI]

    Kemner, Ken

    National School on Neutron and X-ray Scattering June 14-28, 2014 Argonne National Laboratory:00 Dinner Dinner Dinner Dinner Week 1 wrap-up Picnic #12;National School on Neutron and X-ray Scattering Restaurant 9:45 - 10:45 Lecture Interaction of X-rays and Neutrons with Matter Roger Pynn University

  9. Soft X-Ray and Vacuum Ultraviolet Based Spectroscopy of the Actinides

    SciTech Connect (OSTI)

    Tobin, J G

    2011-03-17T23:59:59.000Z

    The subjects of discussion included: VUV photoelectron spectroscopy, X-ray photoelectron spectroscopy, Synchrotron-radiation-based photoelectron spectroscopy, Soft x-ray absorption spectroscopy, Soft x-ray emission spectroscopy, Inverse photoelectron spectroscopy, Bremstrahlung Isochromat Spectroscopy, Low energy IPES, Resonant inverse photoelectron spectroscopy.

  10. Characterization of Microstructure of Severely Deformed Titanium by X-ray Diffraction Profile Analysis

    E-Print Network [OSTI]

    Gubicza, Jenő

    Characterization of Microstructure of Severely Deformed Titanium by X-ray Diffraction Profile deformation, X-ray peak profile analysis. Abstract. Nanocrystalline titanium was produced by equal channel of the measured X-ray diffraction peak profiles. The peak profile analysis provided the median and the variance

  11. X-Ray Emission from Jupiter, Saturn, and Earth: A Short Review

    E-Print Network [OSTI]

    Anil Bhardwaj

    2006-05-11T23:59:59.000Z

    Jupiter, Saturn, and Earth - the three planets having dense atmosphere and a well developed magnetosphere - are known to emit X-rays. Recently, Chandra X-ray Observatory has observed X-rays from these planets, and XMM-Newton has observed them from Jupiter and Saturn. These observations have provided improved morphological, temporal, and spectral characteristics of X-rays from these planets. Both auroral and non-auroral (low-latitude) 'disk' X-ray emissions have been observed on Earth and Jupiter. X-rays have been detected from Saturn's disk, but no convincing evidence for X-ray aurora on Saturn has been observed. The non-auroral disk X-ray emissions from Jupiter, Saturn, and Earth, are mostly produced due to scattering of solar X-rays. X-ray aurora on Earth is mainly generated via bremsstrahlung from precipitating electrons and on Jupiter via charge exchange of highlyionized energetic heavy ions precipitating into the polar atmosphere. Recent unpublished work suggests that at higher (>2 keV) energies electron bremsstrahlung also plays a role in Jupiter's X-ray aurora. This paper summarizes the recent results of X-ray observations on Jupiter, Saturn, and Earth mainly in the soft energy (~0.1-2.0 keV) band and provides a comparative overview.

  12. GENTLE IONISATION AND VIOLENT BREAK-UP OF MOLECULES USING SOFT X-RAYS

    E-Print Network [OSTI]

    Bapat, Bhas

    GENTLE IONISATION AND VIOLENT BREAK-UP OF MOLECULES USING SOFT X-RAYS Bhas Bapat PRL, Ahmedabad RRCAT Indore, June 2012 BHAS BAPAT (PRL, AHMEDABAD) BREAK-UP OF MOLECULES USING SOFT X-RAYS RRCAT INDORE INVESTIGATED RECENT RESULTS BHAS BAPAT (PRL, AHMEDABAD) BREAK-UP OF MOLECULES USING SOFT X-RAYS RRCAT INDORE

  13. Spectral Modeling of X-rays from Hot Star Winds Emma E. Wollman, Swarthmore College `09

    E-Print Network [OSTI]

    Cohen, David

    and absorption. Consequently, the more luminous a star is, the stronger the wind it can support. This wind-driving1 Spectral Modeling of X-rays from Hot Star Winds Emma E. Wollman, Swarthmore College `09 Prof x-ray spectra from Chandra's archive. Models of x-ray production in hot star winds predict broad

  14. At-wavelength and optical metrology of bendable x-ray optics for nanofocusing at the ALS

    E-Print Network [OSTI]

    Yashchuk, Valeriy V.

    2009-01-01T23:59:59.000Z

    metrology of bendable x-ray optics for nanofocusing at theof super-high-quality x-ray optics with sub-microradianalignment of bendable x-ray optics to realize sub-100-nrad

  15. Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance

    E-Print Network [OSTI]

    Yashchuk, V. V.

    2010-01-01T23:59:59.000Z

    Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL:USA 4 Center for X-Ray Optics, Lawrence Berkeley Nationaldevelopment of bendable x-ray optics used for focusing of

  16. Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars

    E-Print Network [OSTI]

    Robert R. Gibson; W. N. Brandt; Donald P. Schneider

    2008-08-19T23:59:59.000Z

    We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL QSOs generally have weaker, blueshifted CIV$\\lambda$1549 emission and broader CIII]$\\lambda$1909 lines. The CIV emission line strength depends on both UV and X-ray luminosity, suggesting that the physical mechanism driving the global Baldwin effect is also associated with X-ray emission.

  17. Laboratory-size three-dimensional x-ray microscope with Wolter type I mirror optics and an electron-impact water window x-ray source

    SciTech Connect (OSTI)

    Ohsuka, Shinji, E-mail: ohsuka@crl.hpk.co.jp [Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu-City, 434-8601 (Japan); The Graduate School for the Creation of New Photonics Industries, 1955-1 Kurematsu-cho, Nishi-ku, Hamamatsu-City, 431-1202 (Japan); Ohba, Akira; Onoda, Shinobu; Nakamoto, Katsuhiro [Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu-City, 434-8601 (Japan); Nakano, Tomoyasu [Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu-City, 434-8601 (Japan); Ray-Focus Co. Ltd., 6009 Shinpara, Hamakita-ku, Hamamatsu-City, 434-0003 (Japan); Miyoshi, Motosuke; Soda, Keita; Hamakubo, Takao [Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8904 (Japan)

    2014-09-15T23:59:59.000Z

    We constructed a laboratory-size three-dimensional water window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques, and observed bio-medical samples to evaluate its applicability to life science research fields. It consists of a condenser and an objective grazing incidence Wolter type I mirror, an electron-impact type oxygen K? x-ray source, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit of around 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-?m scale three-dimensional fine structures were resolved.

  18. Feasibility considerations of a soft-x-ray distributed feedback laser pumped by an x-ray free electron laser

    E-Print Network [OSTI]

    André, Jean-Michel; Jonnard, Philippe

    2014-01-01T23:59:59.000Z

    We discuss the feasibility of a soft-x-ray distributed feedback laser (DFL) pumped by an x-ray free electron laser (X-FEL). The DFL under consideration is a Mg/SiC bi-layered Bragg reflector pumped by a single X-FEL bunch at 57.4 eV, stimulating the Mg L2,3 emission at 49 eV corresponding to the 3s-3d â??2p1/2,3/2 transition. Based on a model developed by Yariv and Yeh and an extended coupled-wave theory, we show that it would be possible to obtain a threshold gain compatible with the pumping provided by available X-FEL facilities.

  19. Note: Experiments in hard x-ray chemistry: In situ production of molecular hydrogen and x-ray induced combustion

    SciTech Connect (OSTI)

    Pravica, Michael; Bai Ligang; Liu Yu; Galley, Martin; Robinson, John [High Pressure Science and Engineering Center (HiPSEC) and Department of Physics, University of Nevada Las Vegas (UNLV), Las Vegas, Nevada 89154-4002 (United States); Park, Changyong [HPCAT, Geophysical Laboratory, Carnegie Institution of Washington, 9700 South Cass Ave., Argonne, Illinois 60437 (United States); Hatchett, David [Department of Chemistry, University of Nevada Las Vegas (UNLV), Las Vegas, Nevada 89154-4003 (United States)

    2012-03-15T23:59:59.000Z

    We have successfully loaded H{sub 2} into a diamond anvil cell at high pressure using the synchrotron x-ray induced decomposition of NH{sub 3}BH{sub 3}. In a second set of studies, radiation-assisted release of O{sub 2} from KCLO{sub 3}, H{sub 2} release from NH{sub 3}BH{sub 3}, and reaction of these gases in a mixture of the reactants to form liquid water using x-rays at ambient conditions was observed. Similar observations were made using a KCLO{sub 3} and NaBH{sub 4} mixture. Depending on reaction conditions, an explosive or far slower reaction producing water was observed.

  20. A Chandra X-ray Study of NGC 1068: II. The Luminous X-ray Source Population

    E-Print Network [OSTI]

    David A. Smith; Andrew S. Wilson

    2003-03-17T23:59:59.000Z

    We present an analysis of the compact X-ray source population in the Seyfert~2 galaxy NGC 1068, imaged with Chandra. We find a total of 84 compact sources, of which 66 are projected onto the galactic disk of NGC 1068. Spectra of the brightest sources have been modeled with both multi-color disk blackbody and power-law models. The power-law model provides the better description of the spectrum for most of these sources. Five sources have 0.4-8 keV intrinsic luminosities greater than 10^{39} erg/s, assuming that their emission is isotropic and that they are associated with NGC 1068. We refer to these sources as Intermediate Luminosity X-ray Objects (IXOs). If these five sources are X-ray binaries accreting with luminosities that are both sub-Eddington and isotropic, then the implied source masses are >7 solar masses, and so they are inferred to be black holes. The brightest source has a much harder spectrum (Gamma = 0.9\\pm0.1) than that found in Galactic black hole candidates and other IXOs. It also shows large-amplitude variability on both short-term and long-term timescales. The ratio of the number of sources with luminosities greater than 2.1 x 10^{38} erg/s in the 0.4-8 keV band to the rate of massive star formation is the same, to within a factor of two, for NGC 1068, the Antennae, NGC 5194 (the main galaxy in M51), and the Circinus galaxy. This suggests that the rate of production of X-ray binaries per massive star is approximately the same for galaxies with currently active star formation, including ``starbursts''.