Powered by Deep Web Technologies
Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Household Light Makes Global Heat: High Black Carbon Emissions From Kerosene Wick Lamps  

Science Journals Connector (OSTI)

(3) Lighting is another component of this household energy challenge, with millions of households still relying on simple liquid-fueled lamps, but little is known of the associated environmental and health impacts. ... For laboratory tests, CO2 and CO concentrations were measured in real-time with a Li-COR 6252 (Li-COR Biosciences, Lincoln, NE) and Horiba AIA-220 (Horiba, Kyoto, Japan) nondispersive infrared (NDIR) analyzer, respectively. ...

Nicholas L. Lam; Yanju Chen; Cheryl Weyant; Chandra Venkataraman; Pankaj Sadavarte; Michael A. Johnson; Kirk R. Smith; Benjamin T. Brem; Joseph Arineitwe; Justin E. Ellis; Tami C. Bond

2012-11-19T23:59:59.000Z

2

Black Carbon and Kerosene Lighting: An Opportunity for Rapid Action on Climate Change and Clean Energy for Development  

SciTech Connect

Replacing inefficient kerosene lighting with electric lighting or other clean alternatives can rapidly achieve development and energy access goals, save money and reduce climate warming. Many of the 250 million households that lack reliable access to electricity rely on inefficient and dangerous simple wick lamps and other kerosene-fueled light sources, using 4 to 25 billion liters of kerosene annually to meet basic lighting needs. Kerosene costs can be a significant household expense and subsidies are expensive. New information on kerosene lamp emissions reveals that their climate impacts are substantial. Eliminating current annual black carbon emissions would provide a climate benefit equivalent to 5 gigatons of carbon dioxide reductions over the next 20 years. Robust and low-cost technologies for supplanting simple wick and other kerosene-fueled lamps exist and are easily distributed and scalable. Improving household lighting offers a low-cost opportunity to improve development, cool the climate and reduce costs.

Jacobson, Arne [Humboldt State Univ., MN (United States). Schatz Energy Research Center; Bond, Tami C. [Univ. of Illinois at Urbana-Champaign, IL (United States). Dept. of Civil and Environmental Engineering; Lam, Nicholoas L. [Univ. of California, Berkeley, CA (United States). Dept. of Environmental Health Sciences; Hultman, Nathan [The Brookings Institution, Washington, DC (United States)

2013-04-15T23:59:59.000Z

3

Lamp Divisions  

Office of Legacy Management (LM)

--- --- /A;; i :' r%i;in~house ilEc;' i:Z3:~cra:ion Lamp Divisions , _.. (I +i. 0 :,,,rg. . I . . -= i?e p/q! qe)-' &se pw E.rcale?l iev, Je!sey 07m March 20, 1 gs? ::r . J. A. Jones I ti. 5. Muclear Regulatory Commission .> = ..- haterials Licensing Branch -s - ,.I, - - Division of Fuel Cycle and hateri al Safety LY. , $2 - _ . ' -' . 3 _- - Yeshington, C. C. 2@555 - :_ :--, =-- -- .-?J -.: y...., : :- 7 Dear Mr. Jones : y-- --, ? . *I 2=15 2 r; X -P The following is our final report of the decontamination efZor?s takz in our Bui Iding 7 basement and wi 11 also serve to update our report i& November 12, 1980. As stated in NRC' s report of December 22, 1983, two closeout inspect ions were conducted by your King of Prussia off i ce on November 21 and December 2,

4

Fuel oil and kerosene sales 1995  

SciTech Connect

This publication contains the 1995 survey results of the ``Annual Fuel Oil and Kerosene Sales Report`` (Form EIA-821). This is the seventh year that the survey data have appeared in a separate publication. Except for the kerosene and on-highway diesel information, data presented in Tables 1 through 12 (Sales of Fuel Oil and Kerosene) present results of the EIA-821 survey. Tables 13 through 24 (Adjusted Sales of Fuel Oil and Kerosene) include volumes that are based on the EIA-821 survey but have been adjusted to equal the product supplied volumes published in the Petroleum Supply Annual (PSA). 24 tabs.

NONE

1996-09-01T23:59:59.000Z

5

Geographic Area Month Aviation Gasoline Kerosene-Type Jet Fuel  

Gasoline and Diesel Fuel Update (EIA)

State (Cents per Gallon Excluding Taxes) - Continued Geographic Area Month Aviation Gasoline Kerosene-Type Jet Fuel Kerosene Sales to End Users Sales for Resale Sales to End...

6

Fuel oil and kerosene sales 1993  

SciTech Connect

This publication contains the 1993 survey results of the ``Annual Fuel Oil and Kerosene, Sales Report`` (Form EIA-821). This is the fifth year that the survey data have appeared in a separate publication. Prior to the 1989 report, the statistics appeared in the Petroleum Marketing Annual (PMA) for reference year 1988 and the Petroleum Marketing Monthly (PMM) for reference years 1984 through 1987. The 1993 edition marks the 10th annual presentation of the results of the ongoing ``Annual Fuel Oil and Kerosene Sales Report`` survey. Except for the kerosene and on-highway diesel information, data presented in Tables 1 through 12 (Sales of Fuel Oil and Kerosene) present results of the EIA-821 survey. Tables 13 through 24 (Adjusted Sales of Fuel Oil and Kerosene) include volumes that are based on the EIA-821 survey but have been adjusted to equal the products supplied volumes published in the Petroleum Supply Annual (PSA).

Not Available

1994-10-03T23:59:59.000Z

7

Fuel oil and kerosene sales 1997  

SciTech Connect

The Fuel Oil and Kerosene Sales 1997 report provides information, illustrations and state-level statistical data on end-use sales of kerosene; No. 1, No. 2, and No. 4 distillate fuel oil; and residual fuel oil. State-level kerosene sales include volumes for residential, commercial, industrial, farm, and all other uses. State-level distillate sales include volumes for residential, commercial, industrial, oil company, railroad, vessel bunkering, military, electric utility, farm, on-highway, off highway construction, and other uses. State-level residual fuel sales include volumes for commercial, industrial, oil company, vessel bunkering, military, electric utility, and other uses. 24 tabs.

NONE

1998-08-01T23:59:59.000Z

8

Fuel Oil and Kerosene Sales 2012  

U.S. Energy Information Administration (EIA) Indexed Site

Fuel Oil and Kerosene Sales Fuel Oil and Kerosene Sales 2012 November 2013 Independent Statistics & Analysis www.eia.gov U.S. Department of Energy Washington, DC 20585 U.S. Energy Information Administration | Fuel Oil and Kerosene Sales 2012 i This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIA's data, analyses, and forecasts are independent of approval by any other officer or employee of the United States Government. The views in this report therefore should not be construed as representing those of the U.S. Department of Energy or other federal agencies. U.S. Energy Information Administration | Fuel Oil and Kerosene Sales 2012 1

9

Fuel oil and kerosene sales 1996  

SciTech Connect

The Fuel Oil and Kerosene Sales 1996 report provides information, illustrations and State-level statistical data on end-use sales of kerosene; No. 1, No. 2, and No. 4 distillate fuel oil; and residual fuel oil. State-level kerosene sales include volumes for residential, commercial, industrial, farm, and all other uses. State-level distillate sales include volumes for residential, commercial, industrial, oil company, railroad, vessel bunkering, military, electric utility, farm, on-highway, off highway construction, and other uses. State-level residual fuel sales include volumes for commercial, industrial, oil company, vessel bunkering, military, electric utility, and other uses. The Petroleum Marketing Division, Office of Oil and Gas, Energy Information Administration ensures the accuracy, quality, and confidentiality of the published data in the Fuel Oil and Kerosene Sales 1996. 24 tabs.

NONE

1997-08-01T23:59:59.000Z

10

Turning on LAMP  

ScienceCinema (OSTI)

Christoph Bostedt, a senior staff scientist at SLAC's Linac Coherent Light Source X-ray laser, provides a sneak peek of a powerful new instrument, called LAMP, that is now available for experiments that probe the atomic and molecular realm. LAMP replaces and updates the first instrument at LCLS, dubbed CAMP, which will be installed at an X-ray laser in Germany.

Bostedt, Christoph

2014-07-16T23:59:59.000Z

11

Turning on LAMP  

SciTech Connect

Christoph Bostedt, a senior staff scientist at SLAC's Linac Coherent Light Source X-ray laser, provides a sneak peek of a powerful new instrument, called LAMP, that is now available for experiments that probe the atomic and molecular realm. LAMP replaces and updates the first instrument at LCLS, dubbed CAMP, which will be installed at an X-ray laser in Germany.

Bostedt, Christoph

2014-06-30T23:59:59.000Z

12

Fluorescent Tube Lamps  

Energy.gov (U.S. Department of Energy (DOE))

FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum efficiency standards for fluorescent lamps. The program will issue updated energy efficiency requirements when the market distribution of this product category stabilizes and when doing so has the potential to result in significant Federal energy savings.

13

Magnetic fluorescent lamp  

DOE Patents (OSTI)

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

14

Energy-efficient incandescent lamp: Final report  

E-Print Network (OSTI)

of Energy Conserving Incandescent Lamps", J . Brett, R.July 1981. "Filaments for Incandescent Lamps with Radiation20-22 "Energy Saving Incandescent Lamps with Infrared

Verderber, R.

2010-01-01T23:59:59.000Z

15

Retail Replacement Lamps  

Energy.gov (U.S. Department of Energy (DOE))

Annual CALiPER testing of A19, G25, candelabra, night light, MR16/PAR16, PAR20, and PAR30 replacement lamps – purchased directly from store shelves – offers insights on performance trends from year to year. The report findings offer valuable insights for manufacturers and retailers alike.

16

LED MR16 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The following CALiPER report provides detailed analysis of LED MR16 lamp performance, covering basic performance characteristics as well as subjective evaluation of beam, shadow, and color quality. Pending reports will offer analysis on performance attributes that are not captured by LM-79 testing. These reports are intended to educate the industry on market trends, potential issues, and important areas for improvement.

17

Fuel oil and kerosene sales 1994  

SciTech Connect

This publication contains the 1994 survey results of the ``Annual Fuel Oil and Kerosene Sales Report`` (Form EIA-821). This is the sixth year that the survey data have appeared in a separate publication. Prior to the 1989 report, the statistics appeared in the Petroleum Marketing Annual (PMA)for reference year 1988 and the Petroleum Marketing Monthly (PMM) for reference years 1984 through 1987. The 1994 edition marks the 11th annual presentation of the results of the ongoing ``Annual Fuel Oil and Kerosene Sales Report`` survey. Distillate and residual fuel oil sales continued to move in opposite directions during 1994. Distillate sales rose for the third year in a row, due to a growing economy. Residual fuel oil sales, on the other hand, declined for the sixth year in a row, due to competitive natural gas prices, and a warmer heating season than in 1993. Distillate fuel oil sales increased 4.4 percent while residual fuel oil sales declined 1.6 percent. Kerosene sales decreased 1.4 percent in 1994.

NONE

1995-09-27T23:59:59.000Z

18

LED PAR38 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The following CALiPER reports provide detailed analysis of LED PAR38 lamp performance, covering basic performance characteristics as well as subjective evaluation of beam, shadow, and color quality. Pending reports will offer analysis on flicker, dimming and power quality characteristics; stress testing; and lumen and chromaticity maintenance. These reports are intended to educate the industry on market trends, potential issues, and important areas for improvement.

19

Max Tech and Beyond: Fluorescent Lamps  

E-Print Network (OSTI)

Fluorescent Lamps and Incandescent Reflector Lamps; Finalmany end- use applications. Incandescent Outdoor Stationaryof color compared with the incandescent reference source is

Scholand, Michael

2012-01-01T23:59:59.000Z

20

Fuel Oil and Kerosene Sales - Energy Information Administration  

U.S. Energy Information Administration (EIA) Indexed Site

Petrolem Reports Petrolem Reports Fuel Oil and Kerosene Sales With Data for 2012 | Release Date: November 15, 2013 | Next Release Date: November 2014 Previous Issues Year: 2012 2011 2010 2009 2008 2007 2006 2005 2004 2003 2002 2001 2000 1999 1998 1997 1996 1995 Go The Fuel Oil and Kerosene Sales 2012 report provides information, illustrations and State-level statistical data on end-use sales of kerosene; No.1, No. 2, and No. 4 distillate fuel oil; and residual fuel oil. State-level kerosene sales include volumes for residential, commercial, industrial, farm, and all other uses. State-level distillate sales include volumes for residential, commercial, industrial, oil company, railroad, vessel bunkering, military, electric utility, farm, on-highway, off-highway construction, and other uses. State-level residual fuel sales

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Energy Cost Calculator for Compact Fluorescent Lamps | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours...

22

Life cycle assessment of off-grid lighting applications : kerosene vs. solar lanterns  

E-Print Network (OSTI)

Access to electricity in developing countries is minimal and if available, often unreliable. As a result, fuel-based kerosene lighting is the most common solution to lighting necessities. However, kerosene combustion affects ...

Dave, Shreya H

2008-01-01T23:59:59.000Z

23

Health Implications of New Lamp Technology Progress with Lamp Safety  

E-Print Network (OSTI)

: ­ ACGIH Threshold Limit Values, UV, lasers, etc. ­ ANSI Z136.1 for lasers with MPEs 0.1 ps -30 ks ­ ANSI RP 27.1 to ANSI RP 27.3 Lamp Safety · Internationally: ­ International Commission on Non

California at Davis, University of

24

Convective heat transfer characteristics of China RP-3 aviation kerosene at supercritical pressure  

E-Print Network (OSTI)

Convective heat transfer characteristics of China RP-3 aviation kerosene at supercritical pressure Keywords: Supercritical pressure Aviation kerosene Convective heat transfer Numerical study a b s t r a c convective in kerosene pipe flow is complicated. Here the convective heat transfer characteristics of China

Guo, Zhixiong "James"

25

Capacitive sensing with a fluorescent lamp  

E-Print Network (OSTI)

This work presents a modified fluorescent lamp that can be used as a capacitive sensing system. The lamp sensor measures changes in the electric fields emitted from the fluorescent bulbs in order to deduce the presence and ...

Cooley, John Jacob

2007-01-01T23:59:59.000Z

26

LED Linear Lamps and Troffer Lighting  

Energy.gov (U.S. Department of Energy (DOE))

The CALiPER program performed a series of investigations on linear LED lamps. Each report in the series covers the performance of up to 31 linear LED lamps, which were purchased in late 2012 or 2013. The first report focuses on bare lamp performance of LED T8 replacement lamps and subsequent reports examine performance in various troffers, as well as cost-effectiveness. There is also a concise guidance document that describes the findings of the Series 21 studies and provides practical advice to manufacturers, specifiers, and consumers (Report 21.4: Summary of Linear (T8) LED Lamp Testing , 5 pages, June 2014).

27

Max Tech and Beyond: Fluorescent Lamps  

E-Print Network (OSTI)

varies by watts of power per foot of electrical arc in theFoot Linear Fluorescent Lamps Efficacy Life Lumens Type Base Power

Scholand, Michael

2012-01-01T23:59:59.000Z

28

Covered Product Category: Compact Fluorescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category.

29

Energy saving controller for fluorescent lamps.  

E-Print Network (OSTI)

??Although fluorescent lamp is a very efficient lighting device in daily life, still the high harmonic distortion and low power factor cause unnecessary energy consumption.… (more)

Cheong, Zhi Xiong

2010-01-01T23:59:59.000Z

30

LED Replacements for Linear Fluorescent Lamps Webcast  

Energy.gov (U.S. Department of Energy (DOE))

In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting...

31

Energy conservation treatment in Exxon's “the lamp  

Science Journals Connector (OSTI)

In this article, Mary Ann Ferguson-DeThorne examines The Lamp, a publication sponsored by Exxon, to determine when and to what extent Exxon informed The Lamp's audience about an impending energy shortage and possible energy conservation methods, to learn if The Lamp's energy conservation messages reflected Exxon's stated conservation positions, and to compare The Lamp to mass-circulation news magazines in terms of how well it alerted its audience to the impending energy shortage. The crucial period of study here is 1971–1973; prior to the Arab oil boycott and the 1974 Congressional investigation of charges that the large oil companies had contrived shortages to eliminate competition.

Mary Ann Ferguson-DeThorne

1978-01-01T23:59:59.000Z

32

General Service LED Lamps | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

DOE SSL technology fact sheet that compares general service LED light bulbs with incandescent and CFL bulbs. ledgeneral-service-lamps.pdf More Documents & Publications LED...

33

A SPICE Compatible Model of High Intensity Discharge Lamps  

E-Print Network (OSTI)

from the arc's * Corresponding author behavior of HID lamps. This model are derived from the arc-linear resistance of the lamp, is the global specific conductance of the plasma, V is the volume of the plasma, L is the length of plasma and S is the cross section. ~ Vin G1 Lamp Model Ballast v(lamp) i(lamp) Analytical

34

General service incandescent lamp with improved efficiency  

SciTech Connect

A high efficiency general service incandescent lamp is disclosed. The disclosed improved general service incandescent lamp has an outer and an inner envelope. The inner envelope has a relatively small housing containing a halogen gas and a relatively high pressure efficient fill-gas and in which a low voltage filament is spatially disposed therein.

Berlec, I.

1985-06-18T23:59:59.000Z

35

Portable lamp with dynamically controlled lighting distribution  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2001-01-01T23:59:59.000Z

36

LED T8 Replacement Lamps | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

T8 Replacement Lamps LED T8 Replacement Lamps This documents provides an overview of LED T8 replacement lamps and helps define a reasonable minimum performance level for the...

37

Solid-state lamp with integral occupancy sensor  

E-Print Network (OSTI)

Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

Cooley, John J.

38

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

as any 1ong-li incandescent lamp or system evaluated in thisEFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGYEFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY

Verderber, Rudy

2013-01-01T23:59:59.000Z

39

DuraLamp USA: Order (2010-CE-0912)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

40

Tungsten wire for incandescent lamps  

SciTech Connect

Tungsten wire for incandescent lamp filaments must operate at high temperatures and for long times. To meet these requirements, the grain morphology of the wire must be controlled to reduce the propensity for grain boundary sliding. The morphology is a function of the distribution of very small pockets of potassium in the wire and the mechanical processing from ingot to wire. The behavior of the filament is directly related to the grain morphology. This paper describes the mechanism by which the potassium is incorporated into and distributed in the ingot. The elongation and spheroidization of the bubbles during hot rolling and swaging is also examined and related to the grain morphology of wire. Some indications of the relationship between grain morphology and filament behavior are also given.

Walter, J.L.; Briant, C.L. (General Electric Corporate Research and Development, Schenectady, NY (USA))

1990-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Power factor and harmonic distortion characteristics of energy efficient lamps  

SciTech Connect

This paper evaluates the performance of a new class of lamps which are generally classified as the energy-saving lamps. It is shown that, when compared with the incandescent lamps, these lamps indeed consume less real power and have higher relative illumination. However, the energy-saving lamps operate at a low power factor and produce current distortion which are much higher than the distortion produced by the traditional incandescent lamps.

Etezadi-Amoli, M.; Florence, T.

1989-07-01T23:59:59.000Z

42

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity  

Science Journals Connector (OSTI)

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity ...

Judy L. Mumford; Ron W. Williams; Debra B. Walsh; Robert M. Burton; David J. Svendsgaard; Jane C. Chuang; Virginia S. Houk; Joellen Lewtas

1991-10-01T23:59:59.000Z

43

Cost effectiveness of long life incandescent lamps and energy buttons  

SciTech Connect

Long-life replacement lamps for the incandescent lamp have been evaluated with regard to their cost effectiveness. The replacements include the use of energy buttons that extend lamp life as well as an adaptive fluorescent circline lamp that will fit into existing incandescent lamp sockets. The initial, operating, and replacement costs for one million lumen hours are determined for each lamp system. It is found that the most important component lighting cost is the operating cost. Using lamps that are less efficient or devices that cause lamps to operate less efficiently are not cost-effective. The adaptive fluorescent circline lamp, even at an initial unit cost of $20.00, is the most cost-effective source of illumination compared to the incandescent lamp and lamp systems examined.

Verderber, R.; Morse, O.

1980-04-07T23:59:59.000Z

44

Lamp system for uniform semiconductor wafer heating  

DOE Patents (OSTI)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

2001-01-01T23:59:59.000Z

45

Compact fluorescent lamp applications in luxury hotels  

SciTech Connect

Over the past several years, consumers, lighting designers, and energy conservationists have paid increasing attention to the special characteristics of compact fluorescent lamps (CFLs). CFLs can typically be used to replace incandescent lamps of three to four times their own wattage, and their color rendering indices (CRIs)-80 to 85-make them virtually indistinguishable from incandescents. The typical 10,0000-hour life of a CFL often makes savings in labor its most desirable feature when compared to a shorter-lived incandescent lamp.

Gilleskie, R.J.

1996-01-01T23:59:59.000Z

46

LED lamp power management system and method  

DOE Patents (OSTI)

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

2013-03-19T23:59:59.000Z

47

MagLab - Arc Lamp Tutorial  

NLE Websites -- All DOE Office Websites (Extended Search)

with 2,000 cells to create an arc across a 4-inch (100 millimeter) gap. When suitable electric generators became available in the late 1870s, the practical use of arc lamps began....

48

CALiPER Retail Lamps Study 3  

SciTech Connect

The CALiPER program first began investigating LED lamps sold at retail stores in 2010, purchasing 33 products from eight retailers and covering six product categories. The findings revealed a fragmented marketplace, with large disparities in performance of different products, accuracy of manufacturer claims, and offerings from different retail outlets. Although there were some good products, looking back many would not be considered viable competitors to other available options, with too little lumen output, not high enough efficacy, or poor color quality. CALiPER took another look in late 2011purchasing 38 products of five different types from nine retailers and the improvement was marked. Performance was up; retailer claims were more accurate; and the price per lumen and price per unit efficacy were down, although the price per product had not changed much. Nonetheless, there was still plenty of room for improvement, with the performance of LED lamps not yet reaching that of well-established classes of conventional lamps (e.g., 75 W incandescent A19 lamps). Since the second retail lamp study was published in early 2012, there has been substantial progress in all aspects of LED lamps available from retailers. To document this progress, CALiPER again purchased a sample of lamps from retail stores 46 products in total, focusing on A19, PAR30, and MR16 lamps but instead of a random sample, sought to select products to answer specific hypotheses about performance. These hypotheses focused on expanding ranges of LED equivalency, the accuracy of lifetime claims, efficacy and price trends, as well as changes to product designs. Among other results, key findings include: There are now very good LED options to compete with 60 W, 75 W, and 100 W incandescent A19 lamps, and 75 W halogen PAR30 lamps. MR16 lamps have shown less progress, but there are now acceptable alternatives to 35 W, 12 V halogen MR16 lamps and 50 W, 120 V halogen MR16 lamps for some applications. Other uses, such as in enclosed luminaires, may require more development. At the same price point, lamps purchased in 2013 tended to have higher output and slightly higher efficacy than in 2011 or 2010. Over 30% of the products purchased in 2013 exceeded the maximum efficacy measured in 2011 (71 lm/W), with the most efficacious product measured at 105 lm/W. There appears to be increasing consistency in color quality, with a vast majority of products having a CCT of 2700 K or 3000 K and a CRI between 80 and 85. There were also fewer poor performing products tested and more high-performing products available in 2013 than in previous years. The accuracy of equivalency and performance claims was better than in 2011, but remains a concern, with 43% of tested products failing to completely meet their equivalency claim and 20% of products failing to match the manufacturer’s performance data. Although progress has been substantial, on average LED lamps remain more expensive than other energy efficiency lighting technologies -- although some aspects can be superior. Although not universal to all product lines or all product types, the issue of insufficient lumen output from LED lamps is waning. Thus, manufacturers can focus on other issues, such as reducing cost, improving electrical/dimmer compatibility, eliminating flicker, or improving color quality. While these issues are not inherent to all products, they remain a concern for the broader market.

Royer, Michael P.; Beeson, Tracy A.

2014-02-01T23:59:59.000Z

49

Building Technologies Office: Fluorescent and Incandescent Lamps Public  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent and Fluorescent and Incandescent Lamps Public Meeting to someone by E-mail Share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Facebook Tweet about Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Twitter Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Google Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Delicious Rank Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Digg Find More places to share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement

50

Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps.  

SciTech Connect

To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light output compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one characteristic, but not others. Consumers (and specifiers) may have a hard time distinguishing better-performing lamps from one another; at this time, physical experimentation is likely the best evaluation tool.

Royer, Michael P.; Poplawski, Michael E.; Brown, Charles C.

2014-12-14T23:59:59.000Z

51

Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Compact Fluorescent Lamps Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps October 8, 2013 - 2:18pm Addthis This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 $/kWh Relamper labor costs $/hr Time taken to retrofit all lamps in this project min Time taken to relamp one lamp min Type of Relamping Practiced: Group Relamping: Calculate Simple Payback Period months

52

Comparison of technologies for new energy-efficient lamps  

SciTech Connect

Energy-efficient light bulbs are being developed to replace the incandescent lamp where they can satisfy the design criteria and be used in sockets that have long hours of annual use. The four technologies discussed here include the compact fluorescent lamp, coated-filament lamp, electrodeless fluorescent lamp, and compact high-intensity discharge lamp. The systems demonstrate efficacy improvements of two to four times that of their incandescent counterparts. These new lamps have required considerable advances in lamp technology. They offer the potential for achieving efficacies close to 80 lumens per watt. These new lamps will reduce the energy used annually by incandescent lamps (190 BkWh) by more than 50% in the 1990s, at which times they will be commonly employed.

Verderber, R.R.; Rubinstein, F.R.

1983-06-01T23:59:59.000Z

53

Comparison of technologies for new energy-efficient lamps  

SciTech Connect

Energy-efficient light bulbs are being developed to replace the incandescent lamp where they can satisfy the design criteria and be used in sockets that have long hours of annual use. The four technologies discussed include the compact fluorescent lamp, coated-filament lamp, electrodeless fluorescent lamp, and compact high-intensity discharge lamp. The systems demonstrate efficacy improvements of two to four times that of their incandescent counterparts. These new lamps have required considerable advances in lamp technology. They offer the potential for achieving efficacies close to 80 lm/W. These new lamps will reduce the energy used annually by incandescent lamps (190 billion kWh) by more than 50 percent in the 1990's, at which times they will be commonly employed.

Verderber, R.R.; Rubinstein, F.M.

1984-09-01T23:59:59.000Z

54

Laboratory Evaluation of LED T8 Replacement Lamp Products  

SciTech Connect

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

2011-05-23T23:59:59.000Z

55

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

formation of the electric discharge arc and the metals emitdefined as electric discharge lamps in which the arc tubelamp - an electric discharge lamp in which the arc tube wall

Scholand, Michael

2012-01-01T23:59:59.000Z

56

Text-Alternative Version: LED Replacements for Linear Fluorescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

Below is the text-alternative version of the "LED Replacements for Linear Fluorescent Lamps" webcast, held June 20, 2011.

57

Medium Base Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Templates for Reporting Test Results mediumbasecfltestreporttemplatev1.1.xlsx More Documents & Publications Fluorescent Lamp Ballasts Showerheads Beverage Vending Machines...

58

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and HID (high-intensity discharge) lamps and all other mercury containing labeled for shipment to a recycling plant for mercury, glass and aluminum recovery. The beneficial re

Baker, Chris I.

59

Lighting Group: Sources and Ballasts: LED Reflector Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Reflector Lamp LED Reflector Lamp LED Reflector Lamp Objective LED reflector lamp The goal of this project is to develop a revolutionary new reflector lamp which offers many advantages over current incandescent reflector lamps, including: three times greater efficiency ten times the rated life greater optical and performance properties use of light emitting diodes (LEDs) to generate the light. Although LEDs have been commercially available since the late 1960Â’s, recent dramatic improvements in LED technology have led to white light devices with efficiencies that meet or exceed those of a standard incandescent lamp. This project will build upon these improvements to develop a new type of source for focusing light. Contact Information For more information on this project, please contact:

60

LED lamp color control system and method  

SciTech Connect

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

2013-02-05T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Fluorescent ballast and lamp disposal issues  

SciTech Connect

All around the world, governments, utility companies, and private businesses are attempting to reduce the amount of energy consumed. In the US alone, new economic strategies and programs are being created to facilitate this process. For instance, the recent enactment of the National Energy Policy Act, the Environmental Protection Agency`s (EPA) Green Lights Program, and a surge of utility involvement in Demand Side Management (DSM) Commercial/Industrial Direct Install and Rebate Programs. Many of these problems target commercial/industrial lighting system retrofits as one of the most cost effective avenues for reducing the consumption of energy. Due to this trend, hundreds of millions of lighting ballasts and lamps are being discarded. The benefits of these programs result in enormous reductions in fossil fuels (and subsequent carbon dioxide, sulfur dioxide, and nitrogen oxide emissions) required to generate the displaced electricity. Throughout the US, however, there is an increasing concern for the environmental impacts surrounding the accelerated disposal of both lighting ballasts and lamps. Regulations initially established were for a one by one, retirement (failure) process rather than promoted obsolescence and forced retirement of lamp groups or entire systems (truckloads of old technologies). Recognizing this trend and the potential negative environmental effects, federal, state, and local regulators are reevaluating the impacts and are being asked to promulgate policies to specifically address this situation.

Leishman, D.L. [Alta Resource Management Services, Inc., Springfield, MA (United States)

1996-12-01T23:59:59.000Z

62

3-D modelling of kerosene-fuelled HVOF thermal spray gun  

Science Journals Connector (OSTI)

Liquid-fuelled high-velocity oxy-fuel (HVOF) thermal spraying systems are capable of generating more momentum output to powder particles in comparison with gas-fuelled systems. The use of low-cost fuel such as kerosene makes this technology particular attractive. High-quality coating requires thermal spraying systems delivering consistent performance as a result of the combustion during HVOF spraying. The combustion of kerosene is very complicated due to the variation of fuel composition and subsequently makes it extremely challenging for process control. This paper describes a 3-D simulation using mathematical models available in a commercial finite volume CFD code. The combustion and discrete particle models within the numerical code are applied to solve the combustion of kerosene and couple the motion of fuel droplets with the gas flow dynamics in a Lagrangian fashion. The effects of liquid fuel droplets on the thermodynamics of the combusting gas flow are examined thoroughly.

S. Kamnis; S. Gu

2006-01-01T23:59:59.000Z

63

,"Kerosene-Type Jet Fuel Sales to End Users Refiner Sales Volumes"  

U.S. Energy Information Administration (EIA) Indexed Site

Kerosene-Type Jet Fuel Sales to End Users Refiner Sales Volumes" Kerosene-Type Jet Fuel Sales to End Users Refiner Sales Volumes" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","Kerosene-Type Jet Fuel Sales to End Users Refiner Sales Volumes",60,"Monthly","9/2013","1/15/1983" ,"Release Date:","12/2/2013" ,"Next Release Date:","1/2/2014" ,"Excel File Name:","pet_cons_refoth_a_epjk_vtr_mgalpd_m.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/pet/pet_cons_refoth_a_epjk_vtr_mgalpd_m.htm" ,"Source:","Energy Information Administration"

64

RF driven sulfur lamp having driving electrodes arranged to cool the lamp  

DOE Patents (OSTI)

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1998-10-20T23:59:59.000Z

65

The National Energy Policy Act and lamp replacement options  

SciTech Connect

The National Policy Act of 1992 involves the creation of energy efficiency standards for a wide range of products including fluorescent and incandescent lamps. Minimum efficacy (lumens per watt) and color rendering index (CRI) standards are mandated for the popular fluorescent lamps: four-foot medium bi-pin, two-foot U-bent, eight-foot slimline and eight-foot high output. Minimum efficacies are mandated for specific incandescent R and PAR reflector lamps. These standards will affect selected colors and designs of fluorescent lamps, the most significant being the standard lamps in the cool white and warm white colors. The incandescent reflector lamps will include the R-30, R-40, PAR-38 lamps above 40 watts, excluding the halogen types. These efficiency and color rendering standards will require end-users and specifiers to select replacement fluorescent lamps from a range of performance characteristics (lumen output, efficacy, CRI and price). The choice of replacement for the R and PAR incandescent lamps will include the halogen designs and compact fluorescent designs. In this paper, replacement options will be analyzed and discussed and the effect of these options on the performance of the lighting system will be explored in detail.

Ryerson, C.

1995-06-01T23:59:59.000Z

66

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

of color compared with the incandescent reference source isin this report. Standard Incandescent Halogen Low-Pressure:value equivalent to an incandescent filament lamp. Taking

Scholand, Michael

2012-01-01T23:59:59.000Z

67

Lamp for generating high power ultraviolet radiation  

DOE Patents (OSTI)

The apparatus is a gas filled ultraviolet generating lamp for use as a liquid purifier. The lamp is powred by high voltage AC, but has no metallic electrodes within or in contact with the gas enclosure which is constructed as two concentric quartz cylinders sealed together at their ends with the gas fill between the cylinders. Cooling liquid is pumped through the volume inside the inner quartz cylinder where an electrically conductive pipe spaced from the inner cylinder is used to supply the cooling liquid and act as the high voltage electrode. The gas enclosure is enclosed within but spaced from a metal housing which is connected to operate as the ground electrode of the circuit and through which the treated fluid flows. Thus, the electrical circuit is from the central pipe, and through the cooling liquid, the gas enclosure, the treated liquid on the outside of the outer quartz cylinder, and to the housing. The high voltage electrode is electrically isolated from the source of cooling liquid by a length of insulated hose which also supplies the cooling liquid.

Morgan, Gary L. (Elkridge, MD); Potter, James M. (Los Alamos, NM)

2001-01-01T23:59:59.000Z

68

DEFINING THE EFFECTIVENESS OF UV LAMPS  

Office of Scientific and Technical Information (OSTI)

ARTI-21CR/610-40030-01 ARTI-21CR/610-40030-01 DEFINING THE EFFECTIVENESS OF UV LAMPS INSTALLED IN CIRCULATING AIR DUCTWORK Final Report Date Published - November 2002 Douglas VanOsdell and Karin Foarde RTI P.O. Box 12194 Research Triangle Park, NC 27709-2194 Prepared for the AIR-CONDITIONING AND REFRIGERATION TECHNOLOGY INSTITUTE 4100 N. Fairfax Drive, Suite 200, Arlington, Virginia 22203 Distribution A - Approved for public release; further dissemination unlimited. DISCLAIMER This report was prepared as an account of work sponsored by the Air-Conditioning and Refrigeration Technology Institute (ARTI) under its "HVAC&R Research for the 21 st Century" (21-CR) program. Neither ARTI, the financial supporters of the 21-CR program, or any agency

69

Application Summary Report 22: LED MR16 Lamps  

SciTech Connect

This report analyzes the independently tested photometric performance of 27 LED MR16 lamps. It describes initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to a selection of benchmark halogen MR16s and ENERGY STAR qualification thresholds. Three types of products were targeted. First, CALiPER sought 3000 K lamps with the highest rated lumen output (i.e., at least 500 lm) or a claim of equivalency to a 50 W halogen MR16 or higher. The test results indicate that while the initial performance of LED MR16s has improved across the board, market-available products still do not produce the lumen output and center beam intensity of typical 50 W halogen MR16 lamps. In fact, most of the 18 lamps in this category had lower lumen output and center beam intensity than a typical 35 W halogen MR16 lamp. Second, CALiPER sought lamps with a CRI of 90 or greater. Only four manufacturers were identified with a product in this category. CALiPER testing confirmed the performance of these lamps, which are a good option for applications where high color fidelity is needed. A vast majority of the LED MR16 lamps have a CRI in the low 80s; this is generally acceptable for ambient lighting, but may not always be acceptable for focal lighting. For typical LED packages, there is a fundamental tradeoff between CRI and efficacy, but the lamps in the high-CRI group in this report still offer comparable performance to the rest of the Series 22 products in other performance areas. Finally, CALiPER sought lamps with a narrow distribution, denoted as a beam angle less than 15°. Five such lamps were purchased. Notably, no lamp was identified as having high lumen output (500 lumens or greater), high CRI (90 or greater), a narrow distribution (15° or less), and an efficacy greater than 60 lm/W. This would be an important achievement for LED MR16s especially if output could reach approximately 700 800 lumens, or the approximate equivalent of a 50 W halogen MR16 lamp. Many factors beyond photometric performance should be considered during specification. For example, performance over time, transformer and dimmer compatibility, and total system performance are all critical to a successful installation. Subsequent CALiPER reports will investigate more complex issues.

Royer, Michael P.

2014-07-23T23:59:59.000Z

70

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

71

Maintaining optimum fluorescent lamp performance under elevated temperature conditions  

SciTech Connect

This paper describes a new technique for optimizing fluorescent lamp performance under elevated temperature conditions. This approach uses a thermo-electric Peltier device to produce a localized cold spot temperature of approximately 40/sup 0/C, allowing the lamps to maintain maximum light output and efficacy independent of prevailing ambient temperatures inside a luminaire. Experimental data show that a 20% increase in light output and a 10% increase in efficacy over typical lamp performance in a warm fixture environment can be obtained using this device. Only 0.25 watts must be supplied to the Peltier device to produce these results.

Siminovitch, M.J.; Rubinstein, F.M.; Clark, T.A.; Verderber, R.R.

1986-04-01T23:59:59.000Z

72

Covered Product Category: Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps October 7, 2013 - 10:48am Addthis ENERGY STAR Qualified Products Federal Energy Management Program (FEMP) provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR.

73

Information Resources: LED Replacements for Linear Fluorescent Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

Replacements for Linear Fluorescent Lamps Webcast Replacements for Linear Fluorescent Lamps Webcast In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting Facts-listed products as well as products evaluated in the latest CALiPER reports. Eric Richman, also of PNNL, reported on a recently completed GATEWAY demonstration project, in which LED and fluorescent lamps were installed in a variety of recessed troffer luminaires for comparison in an office environment. The presentation concluded with a discussion of specifications listed in a newly updated technology fact sheet. View presentation slides View the text-alternative version View the webcast (WMV 16 MB) Download Windows Media Player

74

Burst Radio-Frequency Excited Pulsed Hollow-Cathode Lamp  

Science Journals Connector (OSTI)

Transient emission characteristics of a hollow-cathode lamp driven by a pulsed current in combination with a radio-frequency burst signal are described. The radio-frequency field...

Araki, Tsutomu; Walters, John P; Minami, Shigeo

1980-01-01T23:59:59.000Z

75

DOE Publishes Long-Term Testing Investigation of Retail Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's CALiPER program has released another special report on LED lamps that are available through the retail marketplace and targeted toward general consumers. CALiPER...

76

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

38 TWh, 10% of which was for incandescent lighting (Fig. 3).The electricity consumed in incandescent lighting can be300 and 400 million incandescent lamps in the country. Let

Gadgil, A.J.

2008-01-01T23:59:59.000Z

77

Optimized Magnetic Components Improve Efficiency of Compact Fluorescent Lamps  

E-Print Network (OSTI)

xtures (designed for incandescent bulbs) has allowed residential and small commercial electric customers of incandescent lamps and last 10 times longer [1]. High-frequency electronic ballasts are used to power CFLs

78

DOE Publishes New CALiPER Report on Retail Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's CALiPER program has released a special report on LED lamps available through the retail marketplace and targeted toward general consumers. While previous reports in...

79

Magnetic fluorescent lamp having reduced ultraviolet self-absorption  

DOE Patents (OSTI)

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly (10) is enhanced by providing means (30) for establishing a magnetic field with lines of force along the path of electron flow through the bulb (12) of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, Samuel M. (San Francisco, CA); Richardson, Robert W. (Pelham, NY)

1985-01-01T23:59:59.000Z

80

Perceptions of compact fluorescent lamps in the residential market  

SciTech Connect

Compact fluorescent lamps offer significant energy savings over other forms of residential lighting and last up to 10 times longer than conventional incandescent bulbs. In order to better understand existing barriers to acceptance and future opportunities for growth of compact fluorescent lighting in the residential retrofit sector, a three stage research project was designed and conducted by MACRO Consulting, Inc. Assessment of whether or not the benefits of compact fluorescent lamps are sufficient to overcome price resistance was one of the major purposes of this project. Residential customers were interviewed in focus group sessions to help determine key issues and motivating forces in the lighting/energy saving/cost saving equation. Residential customers in 5 major market areas were contacted by telephone, and data about their awareness, knowledge and use of compact fluorescent lighting were collected. These customers also participated in an attribute rating exercise in which compact fluorescent lamps were compared with fluorescent tubes and incandescent bulbs on a series of product attributes. A price elasticity exercise was also conducted. Teleconferences with retailers of compact fluorescent lamps were conducted in order to explore their knowledge of and attitudes towards compact fluorescent lamps. Customers agree that energy savings and longer life are both positive attributes for residential lighting products, but they are not yet ready to make the switch away from inexpensive, versatile and readily available incandescent bulbs to compact fluorescent lamps. Compact fluorescent lamps are rated poorly (even by satisfied'' users) on each of seven positive attributes of home lighting. Major barriers to increased use of compact fluorescent lamps include price, convenience, and performance. Prices above $10 are considered outrageous''. Product improvements are needed for appearance, light output and versatility.

Weiner, J.; Campbell, C.J. (Macro Consulting, Inc., Mountain View, CA (United States))

1992-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents (OSTI)

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

82

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network (OSTI)

standard for linear fluorescent lamps Length (mm) Minimum efficacy (lm/W) Efficacy for energy conservation

Lin, Jiang

2002-01-01T23:59:59.000Z

83

All mercury lamps contain small amounts of mercury. An electric current passes through the lamp and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our environment from heavy  

E-Print Network (OSTI)

All mercury lamps contain small amounts of mercury. An electric current passes through the lamp and vaporizes the mercury to generate light. Recycling mercury containing lamps protects human health and our the environment by recycling universal wastes, contact EH&S at (949) 824-6200 or visit: www.ehs.uci.edu Mercury

George, Steven C.

84

Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks Page 1 Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks  

E-Print Network (OSTI)

Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks Page 1 Assessing the Risk of Mercury in Drinking Water after UV Lamp Breaks Heidi Borchers University of New Hampshire, Environmental Ultraviolet (UV) lamps generate ultraviolet light through the vaporization of elemental mercury, by using

85

,"U.S. Total Adjusted Distillate Fuel Oil and Kerosene Sales by End Use"  

U.S. Energy Information Administration (EIA) Indexed Site

Distillate Fuel Oil and Kerosene Sales by End Use" Distillate Fuel Oil and Kerosene Sales by End Use" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","Residential",4,"Annual",2012,"6/30/1984" ,"Data 2","Commercial",10,"Annual",2012,"6/30/1984" ,"Data 3","Industrial",9,"Annual",2012,"6/30/1984" ,"Data 4","Farm",4,"Annual",2012,"6/30/1984" ,"Data 5","Electric Power",2,"Annual",2012,"6/30/1984" ,"Data 6","Oil Company",2,"Annual",2012,"6/30/1984"

86

U.S. Sales to End Users Refiner Sales Volumes of Aviation Fuels, Kerosene,  

Gasoline and Diesel Fuel Update (EIA)

Sales Type: Sales to End Users Sales for Resale Sales Type: Sales to End Users Sales for Resale Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: Product Sales Type Area May-13 Jun-13 Jul-13 Aug-13 Sep-13 Oct-13 View History Aviation Gasoline 93.3 8.2 10.0 12.0 10.9 11.4 1983-2013 Kerosene-Type Jet Fuel 32,893.1 32,452.7 33,281.4 32,532.8 29,876.9 29,004.1 1983-2013 Propane (Consumer Grade) 6,321.3 6,161.4 5,990.4 6,377.7 6,892.8 3,264.5 1983-2013 Kerosene 3.5 2.4 3.6 2.2 3.6 8.8 1983-2013 No. 1 Distillate 45.2 31.9 36.3 32.5 44.6 103.0 1983-2013 No. 2 Distillate 11,266.8 11,311.6 11,647.9 11,375.1 11,192.1 12,138.1 1983-2013 No. 2 Diesel Fuel NA NA NA NA NA NA 1994-2013

87

2014-12-30 Issuance: Energy Conservation Standard for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Final Rule  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register final rule regarding energy conservation standards for general service fluorescent lamps and incandescent reflector lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on December 30, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

88

Confirmation of the chromosomal localization of human lamp genes and their exclusion as candidate genes for Salla disease  

Science Journals Connector (OSTI)

Salla disease is an inherited lysosomal storage disorder caused by accumulation of free sialic acid in the lysosomes. Lamp genes, lamp A and lamp B (lysosome associated membrane proteins), are the first known ...

Johanna Schleutker; Leena Haataja; Martin Renlund; Lea Puhakka…

1991-11-01T23:59:59.000Z

89

Low-pressure microwave plasma ultraviolet lamp for water purification  

Science Journals Connector (OSTI)

Low-pressure mercury lamps are commonly used for germicidal applications. The germicidal effect is due to the emission of light at 254 nm, which leads to the destruction of the most waterborne bacteria and viruses. The microwave plasma ultraviolet (UV) lamp (MPUVL) is a new technology for generating a high-intensity UV light and that can be also controlled to operate at 185 nm; irradiation is in air at this wavelength produces ozone. The microwave power is injected into a resonant cavity and the surface wave excitation takes place within the cavity through that part of the discharge tube (fused silica) protruding inside it. The MPUVL has many advantages over conventional lamps, which are limited to an output power in the region of 30 W m-1, while MPUVL can deliver any amount of power per unit length and the tube can be of any shape, length or diameter. This paper describes the design of the MPUVL and compares its efficiency with that of conventional lamps through spectral analysis. Other results, which include the effects of temperature and different power inputs, are also discussed.

A I Al-Shamma'a; I Pandithas; J Lucas

2001-01-01T23:59:59.000Z

90

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry Speaker(s): Francis Rubinstein Date: February 14, 2008 - 12:00pm Location: 90-3122 Fluorescent lamp ballasts are subject to DOE appliance standards and rulemaking. But currently, only ballasts for older fluorescent lamp types, such as T-12 lamps are subject to minimum efficacy limits. The majority of fluorescent lamps now being shipped (T-8 and T-5 types) type are operated by ballasts that will not be subject to DOE rule until 2011. The metric used by DOE for characterizing the electrical efficiency of the fluorescent lamp-ballast system is called Ballast Efficacy Factor (BEF). Because BEF is not normalized, it is of limited utility for rulemaking and is useless for procurement. But by normalizing BEF to the total lamp power, I have

91

Solid-State Lighting: LED Replacement Lamps: Current Performance and the  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacement Lamps: Current LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® to someone by E-mail Share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Facebook Tweet about Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Twitter Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Google Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Delicious Rank Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Digg Find More places to share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on

92

LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR®  

Energy.gov (U.S. Department of Energy (DOE))

This May 19, 2009 webcast summarized CALiPER's recent benchmark testing of common omnidirectional incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral...

93

DOE Publishes CALiPER Report on Cost-Effectiveness of Linear (T8) LED Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's CALiPER program has released Report 21.3, which is part of a series of investigations on linear LED lamps. Report 21.3 details a set of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38W total power draw) or fluorescent lamps (51W total power draw) over a 10-year study period.

94

Future projections for domestic consumption of dual purpose kerosene in Nigeria  

Science Journals Connector (OSTI)

This paper looks at three socio-economic variables in energy consumption framework for energy planning in Nigeria. The consumption of dual purpose kerosene (DPK) was regressed against the real gross domestic product (GDP), commodity's price, and the lagged variable considering a period of 32 years (1970-2001). A statistical model was developed for the local consumption using partial adjustment model with three independent variables. Some statistical tests were carried out which revealed that consumption was significantly related to the three components. Local consumption of DPK was forecast for the period 2001 to 2025 using three different scenarios of the growth rates (the low, the base and the high growth rates) of the independent variables. Expectedly, result shows that consumption is greatest for high GDP/low price and minimum for low GDP/high price scenario.

Adekunle Omolade Adelaja; Sunday Joshua Ojolo

2013-01-01T23:59:59.000Z

95

Transport phenomena in metal-halide lamps a poly-diagnostic study  

E-Print Network (OSTI)

/ spectroscopie. Subject headings: gas discharges / metal-halide lamps / plasma diagnostics / plasma properties-halide arc lamps . . . . . . . . . . . 7 1.3 Scope of ThesisTransport phenomena in metal-halide lamps a poly-diagnostic study Tanya Nimalasuriya #12;Copyright

Eindhoven, Technische Universiteit

96

U.S. Sales to End Users Refiner Sales Volumes of Aviation Fuels, Kerosene,  

Gasoline and Diesel Fuel Update (EIA)

103.5 144.3 150.9 116.6 117.5 101.0 1983-2012 103.5 144.3 150.9 116.6 117.5 101.0 1983-2012 Kerosene-Type Jet Fuel 40,136.3 39,913.9 37,954.6 34,775.2 33,272.0 32,545.7 1983-2012 Propane (Consumer Grade) 3,263.4 2,672.2 3,671.1 3,871.2 4,457.3 5,556.4 1983-2012 Kerosene 139.7 46.0 39.8 30.3 27.1 21.0 1983-2012 No. 1 Distillate 161.0 102.0 100.9 107.8 108.9 108.5 1983-2012 No. 2 Distillate 24,345.6 20,801.6 17,757.7 15,767.1 13,802.1 12,536.7 1983-2012 No. 2 Diesel Fuel NA NA NA NA NA NA 1994-2012 Ultra Low-Sulfur 12,415.9 12,419.4 12,458.2 11,698.0 10,441.1 10,608.9 2007-2012 Low-Sulfur 7,720.2 6,037.6 3,392.4 3,186.1 2,579.3 1,185.4 1994-2012 High-Sulfur 3,419.6 1,403.5 1,028.3 448.8 402.0 427.5 1994-2012 No. 2 Fuel Oil 789.9 941.0 878.9 434.2 379.7 314.9

97

U.S. Sales for Resale Refiner Sales Volumes of Aviation Fuels, Kerosene,  

Gasoline and Diesel Fuel Update (EIA)

May-13 Jun-13 Jul-13 Aug-13 Sep-13 Oct-13 View May-13 Jun-13 Jul-13 Aug-13 Sep-13 Oct-13 View History Aviation Gasoline 413.1 602.6 593.2 547.1 431.5 432.6 1983-2013 Kerosene-Type Jet Fuel 26,119.1 27,197.0 28,168.9 27,226.7 25,645.0 27,379.5 1983-2013 Propane (Consumer Grade) 26,164.7 24,627.2 25,506.9 30,382.5 31,250.8 38,981.9 1983-2013 Kerosene 1,302.3 897.9 1,049.8 1,199.7 1,224.4 1,318.9 1983-2013 No. 1 Distillate 197.2 124.8 141.7 228.9 336.0 947.3 1983-2013 No. 2 Distillate 148,472.9 149,527.5 153,402.1 152,957.9 149,298.1 160,704.2 1983-2013 No. 2 Diesel Fuel NA NA NA NA NA NA 1994-2013 Ultra Low-Sulfur 140,589.9 143,645.5 145,899.9 142,352.7 139,922.9 151,092.7 2007-2013 Low-Sulfur 1,976.7 1,020.9 2,521.9 2,944.3 2,205.9 3,904.5 1994-2013 High-Sulfur

98

DuraLamp USA: Proposed Penalty (2010-CE-0912) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) September 9, 2010 DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. DuraLamp USA: Proposed Penalty (2010-CE-0912) More Documents & Publications DuraLamp USA: Order (2010-CE-0912)

99

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

100

Sulfur Lamps-The Next Generation of Efficient Light?  

NLE Websites -- All DOE Office Websites (Extended Search)

5 5 Sulfur Lamps-The Next Generation of Efficient Light? The figure above is a schematic of the system installed at the National Air and Space Museum and the DOE headquarters in Washington, D.C., Light from the sulfur lamp is focused by a parabolic reflector so that it enters the light pipe within a small angular cone. Light travels down the pipe, reflecting off the prismatic film (A) that lines the outer acrylic tube. The prismatic film reflects the light through total internal reflection (C), an intrinsically efficient process. Some of the light striking the film (at A) is not reflected and "leaks out" of the pipe walls (B), giving the pipe a glowing appearance. A light ray that travels all the way down the pipe will strike the mirror at the end (D) and return back up the pipe.

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Deployment Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International May 23, 2012 Philips Wins First L Prize 2 * August 3, 2011: Philips announced as winner of 60W replacement bulb category * Product distributed thru commercial and retail channels Image courtesy of Philips -...[O]nce an award is made the authorizing Act directs General Services Administration to develop federal purchasing schedules for solid-state lamps that meet or exceed the specifications laid out in the prize category-so long as it is cost effective. I hope the GSA begins this process soon.‖

102

ISSUANCE 2014-12-29: Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Clarification for Energy Conservation Standards and Test Procedures for Fluorescent Lamp Ballasts

103

Photovoltaic experiment using light from a solar simulator lamp  

Science Journals Connector (OSTI)

A photovoltaic cellexperiment utilizing the convenience of a solar simulating type lamp is described. The circuit for obtaining the cell characteristic drives an X?Y plotter to graph continuously the characteristics from short circuit current to the open circuit voltage. Calibration methods and their limitation are discussed for estimating the irradiance to determine the light conversion efficiency of the cell. The diode junction nature of the cell is clearly supported by the agreement between experiment and theory. The experiment should be exceptionally suitable for an undergraduate physics laboratory experiment.

R. H. Chow

1980-01-01T23:59:59.000Z

104

Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions  

SciTech Connect

The lumen depreciation and color shift of 38 different lamps (32 LED, 2 CFL, 1 ceramic metal halide [CMH], 3 halogen) were monitored in a specially developed automated long-term test apparatus (ALTA2) for nearly 14,000 hours. Five samples of each lamp model were tested, with measurements recorded on a weekly basis. The lamps were operated continuously at a target ambient temperature between 44°C and 45°C.

Royer, Michael P.

2014-12-01T23:59:59.000Z

105

Text-Alternative Version: CALiPER Series 21 on LED Linear Lamps and Troffer Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Following is a text version of a video about CALiPER Application Report Series 21 on LED Linear Lamps and Troffer Lighting.

106

Text-Alternative Version: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR®  

Energy.gov (U.S. Department of Energy (DOE))

Below is the text-alternative version of the LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® webcast.

107

DOE Publishes Special CALiPER Report on Retail Lamps | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

retail marketplace and targeted toward general consumers. The report follows similar reports published in 2011 and 2012. LED replacement lamps are available through many retail...

108

LED Linear Lamps and Troffer Lighting: CALiPER Report Series 21  

SciTech Connect

Video about CALiPER Report Series 21 on LED Linear Lamps and Troffer Lighting, featuring interviews with Tracy Beeson and Naomi Miller of Pacific Northwest National Laboratory.

Beeson, Tracy; Miller, Naomi

2014-06-17T23:59:59.000Z

109

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

110

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

111

J.-A. FLEMING. 2014 On the characteristic curves and surfaces of incandescence lamps (Courbes caractristiques des lampes incandescence) ; Phil. Mag.,  

E-Print Network (OSTI)

80 J.-A. FLEMING. 2014 On the characteristic curves and surfaces of incandescence lamps (Courbes caractéristiques des lampes à incandescence) ; Phil. Mag., 5e série, t. XIX, p. 368; I885. L'auteur étudie les résistance correspondant à la force électromotrice vo à laquelle l'incandescence commence à se produire, et r

Paris-Sud XI, Université de

112

Spatial and time-dependent distribution of plasma parameters in the metal-halide arc lamp.  

E-Print Network (OSTI)

Spatial and time-dependent distribution of plasma parameters in the metal-halide arc lamp. A. Khakhaev, L. Luizova, K. Ekimov and A. Soloviev Petrozavodsk State University, Russia The metal-halide arc lamp is an effective light source and its investigation has a long history, but even at present some

Paris-Sud XI, Université de

113

Demonstration Of A Monitoring Lamp To Visualize The Energy Consumption In Houses  

E-Print Network (OSTI)

Demonstration Of A Monitoring Lamp To Visualize The Energy Consumption In Houses Christophe Gisler1://www.unipg.it Abstract. We report on the development of a wireless lamp dedicated to the feedback of energy consumption is a good solution to make people gain awareness of their energy consumption and hence reduce it [1

Paris-Sud XI, Université de

114

Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range  

SciTech Connect

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

Ojanen, Maija; Kaerhae, Petri; Ikonen, Erkki

2010-02-10T23:59:59.000Z

115

CALiPER Report 20.3: Robustness of LED PAR38 Lamps  

SciTech Connect

Three samples of 40 of the Series 20 PAR38 lamps underwent multi-stress testing, whereby samples were subjected to increasing levels of simultaneous thermal, humidity, electrical, and vibrational stress. The results do not explicitly predict expected lifetime or reliability, but they can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs. On average, the 32 LED lamp models tested were substantially more robust than the conventional benchmark lamps. As with other performance attributes, however, there was great variability in the robustness and design maturity of the LED lamps. Several LED lamp samples failed within the first one or two levels of the ten-level stress plan, while all three samples of some lamp models completed all ten levels. One potential area of improvement is design maturity, given that more than 25% of the lamp models demonstrated a difference in failure level for the three samples that was greater than or equal to the maximum for the benchmarks. At the same time, the fact that nearly 75% of the lamp models exhibited better design maturity than the benchmarks is noteworthy, given the relative stage of development for the technology.

Poplawski, Michael E.; Royer, Michael P.; Brown, Charles C.

2014-12-31T23:59:59.000Z

116

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

117

The evolving price of household LED lamps: Recent trends and historical comparisons for the US market  

SciTech Connect

In recent years, household LED light bulbs (LED A lamps) have undergone a dramatic price decline. Since late 2011, we have been collecting data, on a weekly basis, for retail offerings of LED A lamps on the Internet. The resulting data set allows us to track the recent price decline in detail. LED A lamp prices declined roughly exponentially with time in 2011-2014, with decline rates of 28percent to 44percent per year depending on lumen output, and with higher-lumen lamps exhibiting more rapid price declines. By combining the Internet price data with publicly available lamp shipments indices for the US market, it is also possible to correlate LED A lamp prices against cumulative production, yielding an experience curve for LED A lamps. In 2012-2013, LED A lamp prices declined by 20-25percent for each doubling in cumulative shipments. Similar analysis of historical data for other lighting technologies reveals that LED prices have fallen significantly more rapidly with cumulative production than did their technological predecessors, which exhibited a historical decline of 14-15percent per doubling of production.

Gerke, Brian F.; Ngo, Allison T.; Alstone, Andrea L.; Fisseha, Kibret S.

2014-10-14T23:59:59.000Z

118

Performance of "Ultra-High" Efficient Electronic Ballast for HID Lamps  

E-Print Network (OSTI)

. Index Terms--Electronic ballast, HID lamps, resonant inverter, power loss modeling, Silicon Carbide (Si of >95% for the ballast. Diode bridge rectifier EMI filter Resonant Inverter Power Factor Correction 75423, USA Abstract--A new electronic ballast circuit for High Intensity Discharge (HID) lamps

Tolbert, Leon M.

119

,"U.S. Sales to End Users Refiner Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates"  

U.S. Energy Information Administration (EIA) Indexed Site

Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates" Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","U.S. Sales to End Users Refiner Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates",11,"Monthly","9/2013","1/15/1983" ,"Release Date:","12/2/2013" ,"Next Release Date:","1/2/2014" ,"Excel File Name:","pet_cons_refoth_d_nus_vtr_mgalpd_m.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/pet/pet_cons_refoth_d_nus_vtr_mgalpd_m.htm"

120

,"U.S. Sales for Resale Refiner Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates"  

U.S. Energy Information Administration (EIA) Indexed Site

Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates" Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","U.S. Sales for Resale Refiner Sales Volumes of Aviation Fuels, Kerosene, Propane, No.1 and No. 2 Distillates",11,"Monthly","9/2013","1/15/1983" ,"Release Date:","12/2/2013" ,"Next Release Date:","1/2/2014" ,"Excel File Name:","pet_cons_refoth_d_nus_vwr_mgalpd_m.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/pet/pet_cons_refoth_d_nus_vwr_mgalpd_m.htm"

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

122

Sustainable bio kerosene: Process routes and industrial demonstration activities in aviation biofuels  

Science Journals Connector (OSTI)

Abstract Alternative fuels are expected to play a major role in EU in the coming years due European Directives on the promotion of renewable energies and reduction of greenhouse gas emissions in transports. However, while in road transports a variety of possible renewable fuels (mainly biofuels, but also electricity) can be considered, in aviation only high quality paraffinic biofuels can be adopted. This means that biomass must be converted through advanced processes into pure hydrocarbon fuels, fully compatible with the existing systems. The aviation sector is responsible for the 2% of the world anthropogenic CO2 emissions and the 10% of the fuel consumption: airlines’ costs for fuel reach 30% of operating costs. In addition, the aviation traffic is expected to double within 15 years from 2012, while fuel consumption and CO2 emissions should double in 25 years. Thus, more than 2 billion people and 40 Mt of good/cargo will have to be moved every year. In this context, the EU Flightpath set a target of 2 Mt per year for aviation alternative fuel by 2020 (i.e. 4% of annual fuel consumption). New processes towards bio-hydrocarbons are being developed, demonstrated and soon industrialized. The present work explores the possible routes from biomass feedstock to sustainable paraffinic fuels, either through bio or thermo-chemical processes, as well as discusses those more mature, focusing on industrial demonstration initiatives. In fact, while the number of possible options towards paraffinic biofuel production is very large, and covers both thermochemical and biochemical routes, as well as hybrid one, only two pathways are today ready for testing a significant large scale: these are FT and Hydrotreating. Major industrial activities and testing experiences are thus reported in the present work. In this context, the ITAKA group is developing a full value-chain in Europe to produce sustainable drop-in Synthetic Paraffinic Kerosene (SPK) – called HEFA – in an economically, socially and environmentally sound manner, at large scale enough to allow testing its use in existing logistic systems and in normal flight operations in Europe. The generated knowledge will aim to identify and address barriers to innovation. Within ITAKA, possible pre-processing of used (waste) cooking oil (UCO) to make it compatible with current downstream hydroprocessing techniques are being investigated: this can includes esterification of waste oils, as well as catalytic thermal processing, which will be carried out in a pilot unit available at RE-CORD/CREAR. First samples of feedstock oils were collected and characterized, for further investigation towards their conversion into biokerosene through hydrotreatment.

David Chiaramonti; Matteo Prussi; Marco Buffi; Daniela Tacconi

2014-01-01T23:59:59.000Z

123

190 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 30, NO. 1, FEBRUARY 2002 Gap Closure in a Cold Metal Halide Lamp  

E-Print Network (OSTI)

lamp has been investigated using a two-dimensional, plasma transport model. Im- ages are presented- charge devices, lighting, plasma applications. METAL halide high-intensity-discharge (HID) lamps op- erate as high-pressure thermal arcs [1]. The cold fills of HID lamps are typically 50­100 torr of a rare

Kushner, Mark

124

CALiPER Report 21.3: Cost-Effectiveness of Linear (T8) LED Lamps  

SciTech Connect

Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15 minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.

Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.

2014-05-27T23:59:59.000Z

125

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

DOE Patents (OSTI)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

1999-01-01T23:59:59.000Z

126

Is the light emitting diode (LED) an ultimate lamp?  

Science Journals Connector (OSTI)

Simple diagrams are used to show the transformation of a thin “slab” of intrinsic semiconductor (direct gap k elec =k hole ) from an ideal “flat-band” photopumped recombination-radiation light source into an ultimate lamp a p–n junctionlight emitting diode(LED). A photoexcited intrinsic slab of semiconductor can be regarded as an ideal (“flat-band”) light source with however the photogenerated carriers and voltage available externally instead of as recombination radiation (light) if the slab is converted to half p type (one side) and half n type (the other side) i.e. to a p–n junction. If an equal a “bucking ” external voltage is applied resulting in an input current when the photoexcitation is removed the slab becomes again (remains) an ideal “flat-band” light source a p–n junctionLED. In practice the LED takes the form of a p–n heterostructure in order to improve electron–hole injection reduce the absorption of recombination radiation and to make possible—with proper geometries—improved photon escape.

N. Holonyak Jr.

2000-01-01T23:59:59.000Z

127

Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp  

DOE Patents (OSTI)

An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

1998-01-01T23:59:59.000Z

128

LED Linear Lamps and Troffer Lighting: CALiPER Report Series 21  

Energy.gov (U.S. Department of Energy (DOE))

View the video about CALiPER Report Series 21 on LED Linear Lamps and Troffer Lighting, featuring interviews with Tracy Beeson and Naomi Miller of Pacific Northwest National Laboratory.

129

DOE Publishes CALiPER Report on Lumen and Chromaticity Maintenance of LED PAR38 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's CALiPER program has released Report 20.4, which is part of a series of investigations on LED PAR38 lamps. Report 20.4 focuses on lumen maintenance, chromaticity...

130

DOE Publishes CALiPER Snapshot Report on LED A Lamps  

Energy.gov (U.S. Department of Energy (DOE))

DOE's CALiPER program has released a Snapshot Report on LED A lamps, which utilizes the LED Lighting Facts program's extensive product database to help industry stakeholders understand the current state and trajectory of the market for that class

131

DOE Publishes New CALiPER Report on Subjective Evaluation of LED PAR38 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

DOE has published the first in a series of four special investigations intended to extend the findings of CALiPER Application Summary Report 20: LED PAR38 Lamps, which was published late last year.

132

Text-Alternative Version: CALiPER Report Series 20 on LED PAR38 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

Michael Royer, Lighting Engineer, Pacific Northwest National Laboratory: The CALiPER program looks at typical LED lamp performance attributes. As we've gone through the progression of reports, we...

133

MISSION CATHODIQUE A L'INTRIEUR DES LAMPES A INCANDESCENCE ; par M. L. HOULLEVIGUE (1).  

E-Print Network (OSTI)

523 �MISSION CATHODIQUE A L'INT�RIEUR DES LAMPES A INCANDESCENCE ; par M. L. HOULLEVIGUE (1). I. Lorsqu'on survolte fortement une lampe à incandescence à filament de charbon, par exemple en mettant sous incandescent. ' , Fic.. 1. Tous ces effets peuvent être attribués, en première analyse, aux électrons émanés du

Boyer, Edmond

134

ISSUANCE 2015-01-26: Energy Conservation Program: Energy Conservation Standards for High-Intensity Lamps, Notice to Reopen Comment Period  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for High-Intensity Lamps, Notice to Reopen Comment Period

135

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art  

SciTech Connect

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

Miller, Naomi J.

2011-09-01T23:59:59.000Z

136

Energy-Efficient, High-Color-Rendering LED Lamps Using Oxyfluoride and Fluoride Phosphors  

SciTech Connect

LED lamps using phosphor downconversion can be designed to replace incandescent or halogen sources with a 'warm-white' correlated color temperature (CCT) of 2700-3200 K and a color rendering index (CRI) greater than 90. However, these lamps have efficacies of {approx}70% of standard 'cool-white' LED packages (CCT = 4500-6000 K; CRI = 75-80). In this report, we describe structural and luminescence properties of fluoride and oxyfluoride phosphors, specifically a (Sr,Ca){sub 3}(Al,Si)O{sub 4}(F,O):Ce{sup 3+} yellow-green phosphor and a K{sub 2}TiF{sub 6}:Mn{sup 4+} red phosphor, that can reduce this gap and therefore meet the spectral and efficiency requirements for high-efficacy LED lighting. LED lamps with a warm-white color temperature (3088 K), high CRI (90), and an efficacy of {approx}82 lm/W are demonstrated using these phosphors. This efficacy is {approx}85% of comparable cool-white lamps using typical Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+}-based phosphors, significantly reducing the efficacy gap between warm-white and cool-white LED lamps that use phosphor downconversion.

Setlur, A.; Radkov, E; Henderson, C; Her, J; Srivastava, A; Karkada, N; Kishore, M; Kumar, N; Aesram, D; et al.

2010-01-01T23:59:59.000Z

137

DOE Publishes Notice of Public Meeting and Availability of the Framework Document for General Service Lamps Energy Conservation Standards  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy has published a Federal Register notice of public meeting and availability of the framework document regarding energy conservation standards for general service lamps.

138

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

139

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

140

Pump-lamp firing-pulse generator for solid-state lasers  

SciTech Connect

This paper describes a generator that provides, with maximum output-pulse amplitude, sequential or external firing of four INP16/250 (IFP-8000) lamps at a frequency of 1 Hz. The energy and time characteristics of the generator are improved as compared with similar devices, which provides a time instability of the delay between a generator-trigger pulse and the optical pumping pulse of + or - 1 usec. The output-pulse amplitude can be varied according to the type and number of lamps fired. Measures are taken to reduce the supply noise produced in firing-pulse generation and to increase the operating safety of the device.

Denishchik, Y.S.

1985-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

The Fuzzy Design of the Intelligent System for the Energy-Saving Lamps  

Science Journals Connector (OSTI)

In the paper, a intelligent system was proposed. It consists of variable converter and intelligent controller. Variable reactor which concludes variable reactance converter and power converter has wide applications in the soft starting, speed controlling ... Keywords: fuzzy control, variable reactor, intelligent control, power converter, Energy-Saving Lamps

Youxin Yuan; Kaihua Cui; Yiping Xiao; Tieliang Xu

2008-12-01T23:59:59.000Z

142

RF driven sulfur lamp having driving electrodes which face each other  

DOE Patents (OSTI)

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1999-06-22T23:59:59.000Z

143

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

144

Laboratory for Advanced Materials Processing University of Maryland http://www.enma.umd.edu/LAMP  

E-Print Network (OSTI)

) = Rs x (L / W), with Rs: sheet resistance of a layer of this material The sheet resistance is expressedLaboratory for Advanced Materials Processing � University of Maryland http Operating Procedure for LAMP four point probe sheet resistance measurements Overview of 4 point probe

Rubloff, Gary W.

145

Report 20.3: Stress Testing of LED PAR38 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

A small sample of each of the Application Summary Report 20 PAR38 lamp types underwent stress testing that included substantial temperature and humidity changes, electrical variation, and vibration. The results do not directly address expected lifetime, but can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs. (24 pages, December 2014)

146

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

147

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

Simpson, J.E.

1999-06-08T23:59:59.000Z

148

Predicted Pulsed-Power/Flash-Lamp Performance of the NIF Main Amplifier  

SciTech Connect

The laser glass for the National Ignition Facility (NIF) Main Amplifier system is pumped by a system of 192 pulsed power/flash lamp assemblies. Each of these 192 assemblies consists of a 1.6 MJ (nominal) capacitor bank working with a Pre-Ionization/Lamp Check (PILC) pulser to drive an array of 40 flash lamps. This paper describes the predicted performance of these Power Conditioning System (PCS) modules in concert with flashlamp assemblies in NIF. Each flashlamp assembly consists of 20 parallel sets of lamps in series pairs. The sensitivity of system performance to various design parameters of the PILC pulser and the main capacitor bank is described. Results of circuit models are compared to sub-scale flashlamp tests and to measurements taken in tests of a PCS module driving a flashlamp assembly in the First Article NIF Test Module facility at Sandia National Laboratories. Also included are predictions from a physics-based, semi-empirical amplifier gain code.

Fulkerson, E. Steven; Hammond, Jud; Harjes, Henry C.; Moore, William B.S.; Smith, David L.; Wilson, J. Michael

1999-06-22T23:59:59.000Z

149

Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps  

E-Print Network (OSTI)

greater than incandescent lamps [1,2]. In fact, recent technological breakthroughs [3-7] in the high of LED lighting: An incandescent source produces 10 ­ 20 lumens/watt, while several manufacturers have? Incandescent bulbs primarily utilize phase modulating dimming through triac switches to control the power sent

Lehman, Brad

150

Hands On Science with NOAA TITLE: Plate Tectonics and Lava Lamps  

E-Print Network (OSTI)

and geological events?" Answer = heat from radioactive decay · Compare the light bulb in lava to Earth's internal in the lava lamp. · Plot recent earthquakes and volcanic activity on a world map and compare to the location.education.noaa.gov/Ocean_and_Coasts/Ocean_Floor_Features.html USGS Earthquake Hazards - http

151

Energy Savings and NOx Emissions Reduction Potential from the 2012 Federal Legislation to Phase Out Incandescent Lamps in Texas  

E-Print Network (OSTI)

Lamps in Texas Description Value Reference Total Housing Units in Texas in 2013: 10,204,056 Real Estate Center, Texas A&M University3, U.S. Census Bureau4 5 Average Lighting Electricity Usage per House: 1,946 kWh/yr NREL Building America Program6... Savings in Texas: 10,424,973 MWh/yr OSD CFL Savings in Texas: 28,562 MWh/day By 2013, it is estimated that total savings of 10,424,973 MWh/yr would be achieved from replacing incandescent lamps with compact fluorescent lamps (CFL) in residential...

Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit

152

LED lamp or bulb with remote phosphor and diffuser configuration with enhanced scattering properties  

DOE Patents (OSTI)

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor carrier having a conversions material and arranged over an opening to the cavity. The phosphor carrier comprises a thermally conductive transparent material and is thermally coupled to the heat sink structure. An LED based light source is mounted in the optical cavity remote to the phosphor carrier with light from the light source passing through the phosphor carrier. A diffuser dome is included that is mounted over the optical cavity, with light from the optical cavity passing through the diffuser dome. The properties of the diffuser, such as geometry, scattering properties of the scattering layer, surface roughness or smoothness, and spatial distribution of the scattering layer properties may be used to control various lamp properties such as color uniformity and light intensity distribution as a function of viewing angle.

Tong, Tao; Le Toquin, Ronan; Keller, Bernd; Tarsa, Eric; Youmans, Mark; Lowes, Theodore; Medendorp, Jr., Nicholas W; Van De Ven, Antony; Negley, Gerald

2014-11-11T23:59:59.000Z

153

Xenon flash lamp pumped self-frequency doubling NYAB pulsed laser  

Science Journals Connector (OSTI)

Neodymium doped yttrium aluminum borate (NYAB) crystals with sizes up to 45mm have been grown successfully. NYAB rod of 4 ? 12mm was pumped by xenon flash lamp, and several mJ of 0.53?m green laser output was obtained. The oscillation threshold, the pulse duration, the laser beam polarization, and the laser beam divergence were measured to be 78mJ, 100ns, 90% and 2mrad, respectively.

Luo Zundu; Jiang Aidong; Huang Yichuan; Qiu Minwang

1989-01-01T23:59:59.000Z

154

2015-01-28 Issuance: Test Procedure for Fluorescent Lamp Ballasts; Final Rule Correction  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register final rule correction regarding test procedures for fluorescent lamp ballasts, as issued by the Deputy Assistant Secretary for Energy Efficiency on January 28, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

155

Performance, emission and combustion characteristics of DI diesel engine running on blends of calophyllum inophyllum linn oil (honne oil)/diesel fuel/kerosene  

Science Journals Connector (OSTI)

Kerosene (K)/diesel fuel (D)/honne oil (H) blends have a potential to improve the performance and emissions and to be alternatives to neat diesel fuel (ND) and has not been reported in the literature. Experiments have been conducted on DI diesel engine when fuelled with ND, H10 (10%H + 90%D, by volume) to H30, HK10 (10%H + 45%K + 45%D), HK20 (20%H + 40%K + 40%D) and HK30 (30%H + 35%K + 35%D). The emissions [CO, HC and smoke density (SD)] of fuel blend HK20 are found to be lowest, with CO and HC dropping significantly. The NOx level is higher with HK10 to HK30 compared to ND and H10 to H30. The brake thermal efficiency of HK10 to HK30 is almost the same and it is higher as compared to ND and H10 to H30. There is a good trade off between NOx and SD. Peak cylinder pressure and premixed combustion phase increases as kerosene content increases.

B.K. Venkanna; C. Venkataramana Reddy

2011-01-01T23:59:59.000Z

156

Creating markets for new products to replace incandescent lamps: The international experience  

SciTech Connect

Since the summer of 1995, several organizations have been in pursuit of what many consider the Holy Grail of lighting technology--a low-cost, drop-in, energy-efficient replacement for the incandescent lamp. This paper summarizes the international experience in attempting to catalyze the commercialization of a mass-market, replacement product that could have major impact on residential lighting energy consumption in US and EU homes. The technology procurement effort was originally spearheaded by US Federal Government through a loose collaboration between the Department of Defense (DoD), the Environmental Protection Agency (EPA) and the Department of Energy (DOE). The DoD agreed to serve as the anchor buyer for a low-cost, drop-in replacement product for standard-sized light bulbs that provide at least 30 percent energy savings compared to traditional incandescent lamps. In parallel to the US effort, the International Energy Agency launched a co-operative technology procurement effort by assembling large buyers' groups in Finland, the Netherlands, Sweden, and the United Kingdom to pull a similar efficient lighting product into the European market. The lukewarm response from lamp manufacturers to these two technology procurement efforts illustrates the challenges of transforming residential lighting from incandescent to efficient lighting.

Rubinstein, F.; Borg, N.; Horowitz, N.; Narel, T.; Morehouse, E.T. Jr.

1998-07-01T23:59:59.000Z

157

Performance of a novel LED lamp arrangement to reduce SNR fluctuation for multi-user visible light communication systems  

Science Journals Connector (OSTI)

This paper investigates the performance of our recently proposed LED lamp arrangement to reduce the SNR fluctuation from different locations in the room for multi-user visible light...

Wang, Zixiong; Yu, Changyuan; Zhong, Wen-De; Chen, Jian; Chen, Wei

2012-01-01T23:59:59.000Z

158

Total Sales of Kerosene  

U.S. Energy Information Administration (EIA) Indexed Site

End Use: Total Residential Commercial Industrial Farm All Other Period: End Use: Total Residential Commercial Industrial Farm All Other Period: Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: End Use Area 2007 2008 2009 2010 2011 2012 View History U.S. 492,702 218,736 269,010 305,508 187,656 81,102 1984-2012 East Coast (PADD 1) 353,765 159,323 198,762 237,397 142,189 63,075 1984-2012 New England (PADD 1A) 94,635 42,570 56,661 53,363 38,448 15,983 1984-2012 Connecticut 13,006 6,710 8,800 7,437 7,087 2,143 1984-2012 Maine 46,431 19,923 25,158 24,281 17,396 7,394 1984-2012 Massachusetts 7,913 3,510 5,332 6,300 2,866 1,291 1984-2012 New Hampshire 14,454 6,675 8,353 7,435 5,472 1,977 1984-2012

159

A New Rb Lamp Exciter Circuit for Rb atomic clocks and Studies on Transition from Ring to Red mode  

E-Print Network (OSTI)

In this paper we describe the development of novel RF exciter circuit for electrode less Rb lamp. The lamp exciter circuit is a RF oscillator with a a new configuration operating at 60 to 65 MHz frequency with 3 to 4 watt power. The Rb lamp is used in exciting the ground state hyperfine transitions in Rb atom in a glass cell placed inside a tuned microwave cavity, As the frequency of these hyperfine transitions is very stable it is used in the development of Rb atomic clock by phase locking the oven controlled crystal oscillator (OCXO) to this atomic transition frequency. The details of the Rb lamp exciter are presented in the paper.The Lamp is ideally operated in ring mode as in this mode the linewidth is narrow and there is no self reversal. However, high temperature and RF excitation power may drive the Rb lamp to red mode which gives rise to line broadening and self reversal. It is the experience that mode change from ring to red deteriorates the atomic signal strength and S/N. In this paper the reasons of mode change are also discussed.

Savita Singh; Bikash Ghosal; G M Saxena

2010-11-10T23:59:59.000Z

160

Impending U.S. lighting standards will boost market for halogen-infrared lamps: New product line expanding  

SciTech Connect

Many of the incandescent floodlights and spotlights manufactured today will not meet lighting efficiency standards taking effect in the US in 1995. As these models cease production, demand will grow for higher efficiency units to fill this huge market, which now totals about 100 million lamps per year. One prime contender is a new class of halogen lamps that use a spectrally selective coating to reflect heat back onto the filament, reducing the amount of electricity needed to generate light. GE Lighting`s Halogen-IR line is the only series of such lamps currently available to replace the conventional floodlights and spotlights that will be banned by the new standards. Other manufacturers may adopt the technology, however, and the Japanese producer Ushio already sells in the US a line of smaller halogen lamps with a similar heat-reflective coating. In terms of efficacy and lifetime, Halogen-IR lamps out perform standard incandescents and standard halogens, but fall far short of fluorescent, metal halide, and high-pressure sodium sources. These other lighting systems are more appropriate and cost-effective than incandescents for many ambient lighting applications. For accent lighting and other tasks that are best suited to incandescent lighting, however, the Halogen-IR lamp is often a superior choice.

Sardinsky, R.; Shepard, M.

1993-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Mercury Vapor Release from Broken Compact Fluorescent Lamps and In Situ Capture by New Nanomaterial Sorbents  

Science Journals Connector (OSTI)

There is one report of Hg poisoning (acrodynia) in a child exposed to broken tube-type fluorescents in a detailed case study presented by Tunnessen et al. (6). ... Similar release patterns but lower amounts were seen for spent bulbs (example result 90 ?g in 24 h) or from the fracture site of a new bulb after glass removal to simulate cleanup. ... Artificial lighting systems are transitioning from incandescent to compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs in response to the U.S. Energy Independence and Security Act and the EU Ecodesign Directive, which leads to energy ... ...

Natalie C. Johnson; Shawn Manchester; Love Sarin; Yuming Gao; Indrek Kulaots; Robert H. Hurt

2008-06-27T23:59:59.000Z

162

2014-10-14 Issuance: Test Procedures Correction for Fluorescent Lamp Ballasts; Notice of Proposed Rulemaking  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register notice of proposed rulemaking regarding test procedures for fluorescent lamp ballasts, as issued by the Deputy Assistant Secretary for Energy Efficiency on October 14, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

163

Influence of the lamp filling on the pumping conditions in a pulsed YAG:Nd3+ laser  

Science Journals Connector (OSTI)

The pumping conditions in pulsed YAG:Nd3+ lasers are determined, to a great extent, by the filling and the discharge conditions in the pump lamps. It is reported that the highest efficiency under free-oscillation conditions was obtained when krypton discharge lamps were used. These lamps had a discharge gap 60 mm long and 5 mm in diameter. They emitted flashes of about 200 ?sec duration. The best results were obtained when the initial gas pressure was ~1000 torr and the discharge energy was W ~ 100–150 J. The efficiency was lower when the value of W was either larger or smaller. The nature of the filling had little effect on the laser efficiency when xenon and krypton lamps were used to provide energies W close to the nominal value of 250 J. The pumping conditions could not be improved significantly by the use of other fillings (inert gases or their mixtures were used). The principal results obtained were valid also when the lamps were operated at a repetition frequency of ? ? 10 Hz.

Vitalii M Podgaetskii; B V Skvortsov; A N Tokareva

1971-01-01T23:59:59.000Z

164

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, Mark W. (Belmont, MA)

1993-01-01T23:59:59.000Z

165

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, M.W.

1993-02-16T23:59:59.000Z

166

DOE Publishes Final Rule for the Request for Exclusion of 100 Watt R20 Short Incandescent Reflector Lamps from Energy Conservation Standards  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy has published a final rule regarding the request for exclusion of 100 Watt R20 short incandescent reflector lamps from energy conservation standards.

167

A theoretical study of the incandescent filament lamp performance under voltage flicker  

SciTech Connect

Incandescent filament lamp flicker, produced by voltage fluctuation, is a power quality problem that caused engineering concern since the onset of electrical illumination technology. The flicker phenomenon was analyzed and explained in early studies. Standards dealing with acceptable flicker levels are well known, nevertheless, today the discussion about flicker continues to be a top priority topic due to the fact that steady-state and transient voltage waveform distortion is a growing problem in low and medium voltage systems. In many situations voltage flicker is caused by subharmonics and interharmonics of voltage. Cycloconverters, welders and arc furnaces, eccentrically operating tools and integral cycle controlled power equipment are notorious for producing voltage flicker. The goal of this paper is to provide solid mathematical basis for the analytical modeling of incandescent filament lamp flicker when the voltage is nonsinusoidal. A mathematical model that enables the evaluation of the luminous flux modulation caused by noninteger harmonics (subharmonics and interharmonics) is presented. Three situations are detailed: square-wave voltage modulation, sinusoidal modulation and the case of noninteger harmonics with nearly contiguous frequencies.

Peretto, L. [Univ. of Bologna (Italy)] [Univ. of Bologna (Italy); Emanuel, A.E. [Worcester Polytechnic Inst., MA (United States)] [Worcester Polytechnic Inst., MA (United States)

1997-01-01T23:59:59.000Z

168

The Model 5000-16C 1000 WATT FEL Lamp Standard pro-vides absolute calibration of spectral irradiance from 250 nm to  

E-Print Network (OSTI)

The Model 5000-16C 1000 WATT FEL Lamp Standard pro- vides absolute calibration of spectral. It has been selected by the National Institute of Standards and Technology to replace the 1000 watt, DXW-pin 1000 watt lamp that is adapted by Gamma Scientific into a bi-post configuration. It is used

169

Effect of helium addition on discharge characteristics in a flat fluorescent lamp  

SciTech Connect

The discharge characteristics of a multielectrode dual coplanar in a mercury-free flat fluorescent lamp were investigated using brightness-efficiency measurement and the infrared (IR) spectrum and intensified charge coupled device (ICCD) characteristics. The level of brightness was above 14 900 cd/m{sup 2} under the conditions of neon--50% xenon-8% He gas composition, 150 Torr pressure, and 20 kHz alternating current pulse. The ICCD results revealed a faster and wider discharge with a Ne-50% Xe-8% He gas composition. The effect of adding helium (He) to Ne-50% Xe revealed a faster peak emission, as confirmed by ICCD images. From the gated IR emission spectrum, the intensity ratio of I{sub 823nm}/I{sub 828nm} was {approx}8% higher with Ne-50% Xe-8% He than with Ne-50% Xe under the same pressure and applied voltage conditions.

Lee, Seong-Eui; Lee, Ho-Nyeon; Park, Hyoung-Bin; Lee, Kyo Sung; Choi, Kyung Cheol [Materials and Devices Research Center, Samsung Advanced Institute of Technology, Suwon 440-600 (Korea, Republic of); Department of Electronics Engineering, Sejong University, Seoul 143-747 (Korea, Republic of); Department of Electrical Engineering and Computer Science, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701 (Korea, Republic of)

2005-11-01T23:59:59.000Z

170

A Novel High-Power-Factor LED-Lamp Driver Based on a Single-Stage Power Conversion  

Science Journals Connector (OSTI)

This paper proposes a novel single-stage driver for supplying a T8-type light-emitting diode (LED) lamp with high power factor. The presented driver integrates a dual buck-boost converter with coupled inductors and a half-bridge series-resonant converter ... Keywords: converter, driver, light-emitting diode (LED)

Chun An Cheng, En Chih Chang, Ching Shien Tseng, Tsung Yuan Chung

2014-06-01T23:59:59.000Z

171

New Energy Efficiency Standards for Metal Halide Lamp Fixtures to Save on Energy Bills and Reduce Carbon Pollution  

Office of Energy Efficiency and Renewable Energy (EERE)

As part of the Energy Department’s efforts to develop efficiency standards that cut carbon pollution and save money by saving energy, U.S. Energy Secretary Ernest Moniz announced that the Department has finalized new energy efficiency standards for metal halide lamp fixtures.

172

DOE CALiPER Program, Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers  

SciTech Connect

Although lensed troffers are numerous, there are many other types of optical systems as well. This report looked at the performance of three linear (T8) LED lamps chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles) as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.

Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.; Wilkerson, Andrea M.; Beeson, Tracy A.

2014-05-20T23:59:59.000Z

173

Color stable phosphors for LED lamps and methods for preparing them  

SciTech Connect

An LED lamp includes a light source configured to emit radiation with a peak intensity at a wavelength between about 250 nm and about 550 nm; and a phosphor composition configured to be radiationally coupled to the light source. The phosphor composition includes particles of a phosphor of formula I, said particles having a coating composition disposed on surfaces thereof; ((Sr.sub.1-zM.sub.z).sub.1-(x+w)A.sub.wCe.sub.x).sub.3(Al.sub.1-ySi.sub.y-)O.sub.4+y+3(x-w)F.sub.1-y-3(x-w) I wherein the coating composition comprises a material selected from aluminum oxide, magnesium oxide, calcium oxide, barium oxide, strontium oxide, zinc oxide, aluminum hydroxide, magnesium hydroxide, calcium hydroxide, barium hydroxide, strontium hydroxide, zinc hydroxide, aluminum phosphate, magnesium phosphate, calcium phosphate, barium phosphate, strontium phosphate, and combinations thereof; and A is Li, NA, K, or Rb, or a combination thereof; M is Ca, Ba, Mg, Zn, or a combination thereof; and 0

Murphy, James Edward; Setlur, Anant Achyut; Camardello, Samuel Joseph

2013-11-26T23:59:59.000Z

174

Iterative Boltzmann plot method for temperature and pressure determination in a xenon high pressure discharge lamp  

SciTech Connect

The Boltzmann plot method allows to calculate plasma temperatures and pressures if absolutely calibrated emission coefficients of spectral lines are available. However, xenon arcs are not very well suited to be analyzed this way, as there are only a limited number of lines with atomic data available. These lines have high excitation energies in a small interval between 9.8 and 11.5 eV. Uncertainties in the experimental method and in the atomic data further limit the accuracy of the evaluation procedure. This may result in implausible values of temperature and pressure with inadmissible uncertainty. To omit these shortcomings, an iterative scheme is proposed that is making use of additional information about the xenon fill pressure. This method is proved to be robust against noisy data and significantly reduces the uncertainties. Intentionally distorted synthetic data are used to illustrate the performance of the method, and measurements performed on a laboratory xenon high pressure discharge lamp are analyzed resulting in reasonable temperatures and pressures with significantly reduced uncertainties.

Zalach, J.; Franke, St. [INP Greifswald, Felix-Hausdorff-Str. 2, 17489 Greifswald (Germany)

2013-01-28T23:59:59.000Z

175

Analysis of Na and Ba in an atomic fluorescence method with excitation by a pulsed dye laser with lamp pumping  

SciTech Connect

Among the laser methods used in atomic spectroscopy, atomic fluorescence resonance spectroscopy together with an atomic ionization technique make it possible to work with individual atoms. This paper reports on the determination of Na and Ba in aqueous solutions of their salts with atomic fluorescence analysis performed wih a dye laser and lamp pumping, the pulse of generation having a length of 1-2 usec. The detection limit of elements in atomic fluorescence analysis performed wih dye lasers with lamp pumping can be reduced by increasing the spectral density of the laser radiation through narrowing the line of generation, by employing other dyes to excite lines of greater intensity, by improving the recording system of the fluorescence spectra, and by improving the atomization of the samples to be analyzed.

Kukvshim, V.G.

1986-04-01T23:59:59.000Z

176

Design and Realize of the Graphics Platform for LED Lamps’ Layout Based on GDI+ and Dual-Buffer  

Science Journals Connector (OSTI)

Based on the GDI+ class library and dual-buffer technology of .NET framework, the software for LED lamps’ layout is developed. On the basis of determining the scheme of layout platform, the metafile class library model by Composite design-set and the process of calling the LED pixels metafile symbol interface are designed firstly. The design method of realizing the LED pixels metafile visual editing on the drawn LED logical pixel based on GDI+ is analyzed. The dual-buffer technology is used to solve the problem of flicker when fast refreshing. The testing results show that the platform can meet the basic function requirements of engineering application, and realize partial adjust on the process of LED lamps layout without distortion.

Wen Yuanmei; Nie Xinming; Liu Guixiong

2012-01-01T23:59:59.000Z

177

Mechanical design of PlayLamp : a minimally intrusive device for recording the behavior of children at-risk of developmental disorders  

E-Print Network (OSTI)

This thesis paper documents the design process, decisions, and outcomes of the design of the physical form factor of PlayLamp, a device for video and audio recording the development of children at-risk of having developmental ...

Steger, Stephen Andrew

2008-01-01T23:59:59.000Z

178

CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

This December 3, 2013 webinar explored the findings of CALiPER 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps and discussed what attributes to...

179

Local Resistance Profiling of Ultra Shallow Junction Annealed with Combination of Spike Lamp and Laser Annealing Processes using Scanning Spreading Resistance Microscope  

SciTech Connect

Local resistance profiles of ultra shallow boron and arsenic implanted into silicon with energies of 2.0 and 4.0 keV and doses of 2.0x10{sup 15} and 1.0x10{sup 15} ions/cm{sup 2} activated by a combination of conventional spike lamp and laser annealing processes were measured by scanning spreading resistance microscope (SSRM) with a depth resolution of less than 10 nm. The lowest local resistance at the low resistance region in 2.0 keV boron implanted silicon with 1050 deg. C spike lamp annealing followed by 0.35 kW/mm{sup 2} laser annealing was half of that without laser annealing. The lowest local resistance at the low resistance region in the arsenic implanted silicon activated by 1050 deg. C spike lamp annealing followed by 0.39 kW/mm{sup 2} laser annealing was 74% lower than that followed by 0.36 kW/mm{sup 2} laser annealing. The lowest local resistances at the low resistance regions in the arsenic implanted silicon with 0.36 and 0.39 kW/mm{sup 2} laser annealing followed by 1050 deg. C spike lamp annealing were 41 and 33% lower than those with spike lamp annealing followed by laser annealing. Laser annealing followed by spike lamp annealing could suppress the diffusion of the impurities and was suitable for making the ultra shallow and low resistance regions.

Abo, Satoshi; Nishikawa, Kazuhisa; Ushigome, Naoya; Wakaya, Fujio; Takai, Mikio [Center for Quantum Science and Technology under Extreme Conditions, Osaka University, 1-3, Machikaneyama, Toyonaka, Osaka, 560-8531 (Japan); Iwamatsu, Toshiaki; Oda, Hidekazu [Advanced Device Technology Department, Production and Technology Unit, Devices and Analysis Technology Division, Renesas Electronics Corporation, 751, Horiguchi, Hitachinaka, Ibaraki, 312-8504 (Japan)

2011-01-07T23:59:59.000Z

180

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

SciTech Connect

Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

2009-03-21T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Glass and glass-derivative seals for use in energy-efficient fuel cells and lamps  

SciTech Connect

For solid oxide fuel cells (SOFC), a series of 18 sealing glasses have been prepared and characterized. From the whole design space, several glasses were ''downselected'' and studied in detail to describe their behaviors in simulated fuel cell environments. One of the glasses was found to outperform all others, including the well-known G18 sealant developed at Pacific Northwest National Laboratory. The new glass composition showed lower bulk electrical conductivity, excellent sealing and wetting behavior when sealing under applied load, and qualitatively superior performance when exposed to wet hydrogen for 800 hours. Traditional melting was used to prepare all of the glasses that were studied in detail. The sol-gel approach was used to synthesize several compositions, but it was found that the glasses crystallized very rapidly during heating, precluding sealing. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. The body of fundamental data provides a platform for future developments for high temperature sealants, and the newly-developed glass compositions appear promising for large-scale testing. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria-alumina-silica system at various silica levels. Functional testing of one of the candidate sealants demonstrated that it performs well in current HID lighting applications. Further testing is required to evaluate its performance in next-generation lamps that operate at higher temperatures, but the baseline phase equilibria and crystallization behavior has been established for additional development. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase.

Scott Misture; Arun Varshineya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2005-07-28T23:59:59.000Z

182

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED) Bulbs  

Science Journals Connector (OSTI)

Artificial lighting systems are transitioning from incandescent to compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs in response to the U.S. Energy Independence and Security Act and the EU Ecodesign Directive, which leads to energy savings and reduced greenhouse gas emissions. ... The CFLs and LEDs have higher resource depletion and toxicity potentials than the incandescent bulb due primarily to their high aluminum, copper, gold, lead, silver, and zinc. ... mercury pollution; redn. in electricity demand from the substitution of incandescent bulbs with fluorescents leads to reduced mercury emissions during the use of the bulb. ...

Seong-Rin Lim; Daniel Kang; Oladele A. Ogunseitan; Julie M. Schoenung

2012-12-13T23:59:59.000Z

183

2014-05-05 Issuance: Test Procedures for High-Intensity Discharge Lamps; Supplemental Notice of Proposed Rulemaking  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register supplemental notice of proposed rulemaking regarding test procedures for high-intesity discharge lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on May 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

184

2015-01-26 Issuance: Energy Conservation Standards for General Service Lamps; Extension of Public Comment Period  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register extension of comment period regarding energy conservation standards for general service lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on January 26, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

185

Kerosene Sales for Residential Use  

Gasoline and Diesel Fuel Update (EIA)

325,320 157,505 205,136 215,587 137,232 57,316 1984-2012 325,320 157,505 205,136 215,587 137,232 57,316 1984-2012 East Coast (PADD 1) 267,992 126,642 159,414 172,303 107,007 47,028 1984-2012 New England (PADD 1A) 75,986 33,235 44,681 41,961 29,375 12,315 1984-2012 Connecticut 5,428 2,061 1,938 1,794 1,303 580 1984-2012 Maine 40,203 17,657 22,748 22,057 15,638 6,295 1984-2012 Massachusetts 6,783 2,633 4,172 4,214 2,585 1,219 1984-2012 New Hampshire 12,493 5,880 7,758 6,854 4,930 1,830 1984-2012 Rhode Island 675 441 1,002 746 551 258 1984-2012 Vermont 10,403 4,563 7,062 6,297 4,369 2,133 1984-2012 Central Atlantic (PADD 1B) 109,558 55,603 78,260 82,460 54,894 25,429 1984-2012 Delaware 2,040 1,048 2,224 1,672 1,043 441 1984-2012 District of Columbia 0 0 0 0 0 0 1984-2012

186

Total Adjusted Sales of Kerosene  

U.S. Energy Information Administration (EIA) Indexed Site

End Use: Total Residential Commercial Industrial Farm All Other Period: End Use: Total Residential Commercial Industrial Farm All Other Period: Annual Download Series History Download Series History Definitions, Sources & Notes Definitions, Sources & Notes Show Data By: End Use Area 2007 2008 2009 2010 2011 2012 View History U.S. 492,702 218,736 269,010 305,508 187,656 81,102 1984-2012 East Coast (PADD 1) 353,765 159,323 198,762 237,397 142,189 63,075 1984-2012 New England (PADD 1A) 94,635 42,570 56,661 53,363 38,448 15,983 1984-2012 Connecticut 13,006 6,710 8,800 7,437 7,087 2,143 1984-2012 Maine 46,431 19,923 25,158 24,281 17,396 7,394 1984-2012 Massachusetts 7,913 3,510 5,332 6,300 2,866 1,291 1984-2012 New Hampshire 14,454 6,675 8,353 7,435 5,472 1,977 1984-2012

187

Kerosene Sales for Industrial Use  

Gasoline and Diesel Fuel Update (EIA)

88,372 22,445 25,536 45,145 22,557 12,920 1984-2012 88,372 22,445 25,536 45,145 22,557 12,920 1984-2012 East Coast (PADD 1) 34,350 10,998 15,113 36,274 15,732 9,177 1984-2012 New England (PADD 1A) 7,027 3,968 6,700 5,785 5,752 2,148 1984-2012 Connecticut 6,143 3,261 6,133 5,297 5,408 1,507 1984-2012 Maine 661 191 116 79 37 22 1984-2012 Massachusetts 84 9 426 119 22 8 1984-2012 New Hampshire 103 205 4 27 86 5 1984-2012 Rhode Island 1 129 0 0 0 0 1984-2012 Vermont 35 172 21 263 199 606 1984-2012 Central Atlantic (PADD 1B) 22,319 6,224 6,981 28,376 8,916 6,571 1984-2012 Delaware 5 2 181 164 0 0 1984-2012 District of Columbia 0 0 0 0 0 0 1984-2012 Maryland 207 133 107 87 27 3 1984-2012 New Jersey 10,815 3,713 2,988 3,886 1,948 610 1984-2012

188

Kerosene Sales for Farm Use  

Gasoline and Diesel Fuel Update (EIA)

9,531 4,893 6,414 6,763 3,410 1,712 1984-2012 9,531 4,893 6,414 6,763 3,410 1,712 1984-2012 East Coast (PADD 1) 2,946 1,190 1,660 1,564 1,726 822 1984-2012 New England (PADD 1A) 1,221 394 457 341 164 161 1984-2012 Connecticut 1 78 1 2 2 0 1984-2012 Maine 648 71 118 66 45 91 1984-2012 Massachusetts 1 14 8 9 0 1 1984-2012 New Hampshire 209 101 9 10 8 3 1984-2012 Rhode Island 0 0 0 0 0 0 1984-2012 Vermont 361 130 321 255 110 66 1984-2012 Central Atlantic (PADD 1B) 980 329 866 669 1,236 518 1984-2012 Delaware 8 4 5 11 3 1 1984-2012 District of Columbia 0 0 0 0 0 0 1984-2012 Maryland 115 46 43 45 24 42 1984-2012 New Jersey 3 3 207 6 1 1 1984-2012 New York 626 224 268 329 888 421 1984-2012 Pennsylvania 228 53 343 277 321 53 1984-2012

189

A numerical study of the supply mode effects on high-pressure mercury discharge lamp dynamic thermal behavior  

SciTech Connect

This paper presents a numerical study of the dynamic behavior of high-pressure mercury discharge lamp as a function of supply mode. Bidimensional time-dependent equations have been solved by using a semi-implicit finite-element code. The model has been developed in the frame of the local thermodynamic equilibrium hypothesis. After validation by using experimental data from the literature, this model was applied to analyze the effects of some key parameters such as frequency for an ac arc current and the ratio cycle parameter for square arc-current wave form on the convective process. The results obtained have been used to analyze the dynamic thermal behavior of high-pressure mercury plasma (pressure equal to 0.3 MPa) working under currents widely different in frequency and wave form.

Kaziz, S.; Ahmed, R. Ben; Araoud, Z.; Gazzah, M.H.; Charrada, K.; Said, R. [EMIR, IPEIM, route de Skanes, 5019 Monastir (Tunisia); FSM, avenue de l'environnement, 5019 Monastir (Tunisia); EMIR, IPEIM, route de Skanes, 5019 Monastir (Tunisia)

2005-06-15T23:59:59.000Z

190

Jade Sky Technologies Partners with CLTC on LED Replacement Lamp Upgrade Project UC Davis' California Lighting Technology Center will utilize Jade Sky Technologies' driver ICs to help spur  

E-Print Network (OSTI)

Jade Sky Technologies Partners with CLTC on LED Replacement Lamp Upgrade Project UC Davis of cost-effective, easy-to-use LED lighting solutions Milpitas, Calif. ­ October 15, 2013 ­ Jade Sky Technologies (JST), a clean-tech start-up manufacturer of driver ICs for LED lighting applications, announces

California at Davis, University of

191

Facility for high-heat flux testing of irradiated fusion materials and components using infrared plasma arc lamps  

Science Journals Connector (OSTI)

A new high-heat flux testing (HHFT) facility using water-wall stabilized high-power high-pressure argon plasma arc lamps (PALs) has been developed for fusion applications. It can accommodate irradiated plasma facing component materials and sub-size mock-up divertor components. Two PALs currently available at Oak Ridge National Laboratory can provide maximum incident heat fluxes of 4.2 and 27 MW m?2, which are prototypic of fusion steady state heat flux conditions, over a heated area of 9 ? 12 and 1 ? 10 cm2, respectively. The use of PAL permits the heat source to be environmentally separated from the components of the test chamber, simplifying the design to accommodate safe testing of low-level irradiated articles and materials under high-heat flux. Issues related to the operation and temperature measurements during testing of tungsten samples are presented and discussed. The relative advantages and disadvantages of this photon-based HHFT facility are compared to existing e-beam and particle beam facilities used for similar purposes.

Adrian S Sabau; Evan K Ohriner; Jim Kiggans; David C Harper; Lance L Snead; Charles R Schaich

2014-01-01T23:59:59.000Z

192

Facility for high heat flux testing of irradiated fusion materials and components using infrared plasma arc lamps  

SciTech Connect

A new high-heat flux testing facility using water-wall stabilized high-power high-pressure argon Plasma Arc Lamps (PALs) has been developed for fusion applications. It can handle irradiated plasma facing component materials and mock-up divertor components. Two PALs currently available at ORNL can provide maximum incident heat fluxes of 4.2 and 27 MW/m2 over a heated area of 9x12 and 1x10 cm2, respectively, which are fusion-prototypical steady state heat flux conditions. The facility will be described and the main differences between the photon-based high-heat flux testing facilities, such as PALs, and the e-beam and particle beam facilities more commonly used for fusion HHF testing are discussed. The components of the test chamber were designed to accommodate radiation safety and materials compatibility requirements posed by high-temperature exposure of low levels irradiated tungsten articles. Issues related to the operation and temperature measurements during testing are presented and discussed.

Sabau, Adrian S [ORNL] [ORNL; Ohriner, Evan Keith [ORNL] [ORNL; Kiggans, Jim [ORNL] [ORNL; Harper, David C [ORNL] [ORNL; Snead, Lance Lewis [ORNL] [ORNL; Schaich, Charles Ross [ORNL] [ORNL

2014-01-01T23:59:59.000Z

193

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

SciTech Connect

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

2013-10-01T23:59:59.000Z

194

Results from the Carbon-Land Model Intercomparison Project (C-LAMP) and Availability of the Data on the Earth System Grid (ESG)  

SciTech Connect

This paper describes the Carbon-Land Model Intercomparison Project (C-LAMP) being carried out through a collaboration between the Community Climate System Model (CCSM) Biogeochemistry Working Group, a DOE SciDAC-2 project, and the DOE Program for Climate Model Diagnosis and Intercomparison (PCMDI). The goal of the project is to intercompare terrestrial biogeochemistry models running within the CCSM framework to determine the best set of processes to include in future versions of CCSM. As a part of the project, observational datasets are being collected and used to score the scientific performance of these models following a well-defined set of metrics. In addition, metadata standards for terrestrial biosphere models are being developed to support archival and distribution of the C-LAMP model output via the Earth System Grid (ESG). Progress toward completion of this project and preliminary results from the first set of experiments are reported.

Hoffman, Forrest M [ORNL; Covey, Curtis [Lawrence Livermore National Laboratory (LLNL); Fung, Inez [University of California, Berkeley; Randerson, Jim [University of California, Irvine; Thornton, Peter [National Center for Atmospheric Research (NCAR); Lee, Jeff [National Center for Atmospheric Research (NCAR); Rosenbloom, Nan [National Center for Atmospheric Research (NCAR); Stockli, Reto [Colorado State University, Fort Collins; Running, Steven [University of Montana, Missoula; Bernholdt, David E [ORNL; Williams, Dean [Lawrence Livermore National Laboratory (LLNL)

2007-01-01T23:59:59.000Z

195

DOE/EA-1664: Environmental Assessment for 10 CFR 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps (June 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 4 Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps June 2009 16-i CHAPTER 16. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 16.1 INTRODUCTION ......................................................................................................... 16-1 16.2 AIR EMISSIONS ANALYSIS...................................................................................... 16-1 16.2.1 Air Emissions Descriptions............................................................................................ 16-1 16.2.2 Air Quality Regulation................................................................................................... 16-3 16.2.3 Global Climate Change..................................................................................................

196

Phosphors for LED lamps  

SciTech Connect

A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

2013-08-13T23:59:59.000Z

197

The Carbon-Land Model Intercomparison Project (C-LAMP): A Model-Data Comparison System for Evaluation of Coupled Biosphere-Atmosphere Models  

SciTech Connect

The need to capture important climate feebacks in general circulation models (GCMs) has resulted in new efforts to include atmospheric chemistry and land and ocean biogeochemistry into the next generation of production climate models, now often referred to as Earth System Models (ESMs). While many terrestrial and ocean carbon models have been coupled to GCMs, recent work has shown that such models can yield a wide range of results, suggesting that a more rigorous set of offline and partially coupled experiments, along with detailed analyses of processes and comparisons with measurements, are warranted. The Carbon-Land Model Intercomparison Project (C-LAMP) provides a simulation protocol and model performance metrics based upon comparisons against best-available satellite- and ground-based measurements (Hoffman et al., 2007). C-LAMP provides feedback to the modeling community regarding model improvements and to the measurement community by suggesting new observational campaigns. C-LAMP Experiment 1 consists of a set of uncoupled simulations of terrestrial carbon models specifically designed to examine the ability of the models to reproduce surface carbon and energy fluxes at multiple sites and to exhibit the influence of climate variability, prescribed atmospheric carbon dioxide (CO{sub 2}), nitrogen (N) deposition, and land cover change on projections of terrestrial carbon fluxes during the 20th century. Experiment 2 consists of partially coupled simulations of the terrestrial carbon model with an active atmosphere model exchanging energy and moisture fluxes. In all experiments, atmospheric CO{sub 2} follows the prescribed historical trajectory from C{sup 4}MIP. In Experiment 2, the atmosphere model is forced with prescribed sea surface temperatures (SSTs) and corresponding sea ice concentrations from the Hadley Centre; prescribed CO{sub 2} is radiatively active; and land, fossil fuel, and ocean CO{sub 2} fluxes are advected by the model. Both sets of experiments have been performed using two different terrestrial biogeochemistry modules coupled to the Community Land Model version 3 (CLM3) in the Community Climate System Model version 3 (CCSM3): The CASA model of Fung, et al., and the carbon-nitrogen (CN) model of Thornton. Comparisons against Ameriflus site measurements, MODIS satellite observations, NOAA flask records, TRANSCOM inversions, and Free Air CO{sub 2} Enrichment (FACE) site measurements, and other datasets have been performed and are described in Randerson et al. (2009). The C-LAMP diagnostics package was used to validate improvements to CASA and CN for use in the next generation model, CLM4. It is hoped that this effort will serve as a prototype for an international carbon-cycle model benchmarking activity for models being used for the Inter-governmental Panel on Climate Change (IPCC) Fifth Assessment Report. More information about C-LAMP, the experimental protocol, performance metrics, output standards, and model-data comparisons from the CLM3-CASA and CLM3-CN models are available at http://www.climatemodeling.org/c-lamp.

Hoffman, Forrest M [ORNL; Randerson, Jim [University of California, Irvine; Thornton, Peter E [ORNL; Mahowald, Natalie [Cornell University; Bonan, Gordon [National Center for Atmospheric Research (NCAR); Running, Steven [University of Montana, Missoula; Fung, Inez [University of California, Berkeley

2009-01-01T23:59:59.000Z

198

2014-12-05 Issuance: Energy Conservation Standard for General Service Lamps; Notice of Public Meeting and Availability of the Preliminary Technical Support Document  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register notice of public meeting and availability of the preliminary technical support document regarding energy conservation standards for general service lamps, as issued by the Deputy Assistant Secretary for Energy Efficiency on December 5, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

199

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search  

SciTech Connect

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

NONE

1997-01-01T23:59:59.000Z

200

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent database). Published Search  

SciTech Connect

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography. (Contains a minimum of 97 citations and includes a subject term index and title list.)

Not Available

1993-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search  

SciTech Connect

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

NONE

1995-12-01T23:59:59.000Z

202

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search  

SciTech Connect

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography. (Contains a minimum of 115 citations and includes a subject term index and title list.)

NONE

1995-02-01T23:59:59.000Z

203

Thorium, uranium and rare earth elements content in lanthanide concentrate (LC) and water leach purification (WLP) residue of Lynas advanced materials plant (LAMP)  

SciTech Connect

Lynas Advanced Materials Plant (LAMP) has been licensed to produce the rare earths elements since early 2013 in Malaysia. LAMP processes lanthanide concentrate (LC) to extract rare earth elements and subsequently produce large volumes of water leach purification (WLP) residue containing naturally occurring radioactive material (NORM). This residue has been rising up the environmental issue because it was suspected to accumulate thorium with significant activity concentration and has been classified as radioactive residue. The aim of this study is to determine Th-232, U-238 and rare earth elements in lanthanide concentrate (LC) and water leach purification (WLP) residue collected from LAMP and to evaluate the potential radiological impacts of the WLP residue on the environment. Instrumental Neutron Activation Analysis and ?-spectrometry were used for determination of Th, U and rare earth elements concentrations. The results of this study found that the concentration of Th in LC was 1289.7 ± 129 ppm (5274.9 ± 527.6Bq/kg) whereas the Th and U concentrations in WLP were determined to be 1952.9±17.6 ppm (7987.4 ± 71.9 Bq/kg) and 17.2 ± 2.4 ppm respectively. The concentrations of Th and U in LC and WLP samples determined by ?- spectrometry were 1156 ppm (4728 ± 22 Bq/kg) and 18.8 ppm and 1763.2 ppm (7211.4 Bq/kg) and 29.97 ppm respectively. This study showed that thorium concentrations were higher in WLP compare to LC. This study also indicate that WLP residue has high radioactivity of {sup 232}Th compared to Malaysian soil natural background (63 - 110 Bq/kg) and come under preview of Act 304 and regulations. In LC, the Ce and Nd concentrations determined by INAA were 13.2 ± 0.6% and 4.7 ± 0.1% respectively whereas the concentrations of La, Ce, Nd and Sm in WLP were 0.36 ± 0.04%, 1.6%, 0.22% and 0.06% respectively. This result showed that some amount of rare earth had not been extracted and remained in the WLP and may be considered to be reextracted.

AL-Areqi, Wadeeah M., E-mail: walareqi@yahoo.com; Majid, Amran Ab., E-mail: walareqi@yahoo.com; Sarmani, Sukiman, E-mail: walareqi@yahoo.com [Nuclear Science Programme, School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi (Malaysia)

2014-02-12T23:59:59.000Z

204

Kerosene Sales for All Other Uses  

Gasoline and Diesel Fuel Update (EIA)

1,520 1,036 633 2,297 809 245 1984-2012 1,520 1,036 633 2,297 809 245 1984-2012 East Coast (PADD 1) 795 248 336 1,110 558 120 1984-2012 New England (PADD 1A) 232 23 31 10 105 49 1984-2012 Connecticut 8 5 18 0 0 0 1984-2012 Maine 16 6 3 0 99 45 1984-2012 Massachusetts 0 0 0 2 0 0 1984-2012 New Hampshire 6 1 0 2 2 1 1984-2012 Rhode Island 0 0 0 0 1 2 1984-2012 Vermont 203 12 10 6 3 1 1984-2012 Central Atlantic (PADD 1B) 408 133 79 277 113 56 1984-2012 Delaware 0 0 0 0 0 0 1984-2012 District of Columbia 0 0 0 0 0 0 1984-2012 Maryland 10 4 3 11 4 1 1984-2012 New Jersey 81 0 7 8 0 2 1984-2012 New York 205 88 18 179 89 40 1984-2012 Pennsylvania 112 41 51 79 19 13 1984-2012 Lower Atlantic (PADD 1C) 154 92 225 823 341 16 1984-2012

205

Prices of Refiner Kerosene Sales for Resale  

Gasoline and Diesel Fuel Update (EIA)

May-13 Jun-13 Jul-13 Aug-13 Sep-13 Oct-13 View May-13 Jun-13 Jul-13 Aug-13 Sep-13 Oct-13 View History U.S. 2.793 2.806 2.996 3.055 3.057 3.029 1983-2013 East Coast (PADD 1) 3.018 2.989 3.173 3.132 3.172 3.182 1983-2013 New England (PADD 1A) W - - W W NA 1983-2013 Connecticut W - - W W NA 1984-2013 Maine - - - - - - 1984-2013 Massachusetts - - - - - - 1984-2013 New Hampshire - - - - - - 1984-2013 Rhode Island - - - - - - 1984-2013 Vermont - - - - - - 1984-2013 Central Atlantic (PADD 1B) 2.952 2.985 3.173 3.096 3.146 3.140 1983-2013 Delaware - W W - W W 1984-2013 District of Columbia - - - - - - 1984-2013 Maryland W W W W W W 1984-2013 New Jersey W W W W W W 1984-2013 New York W W W W 3.328 3.258 1984-2013 Pennsylvania W W W W 3.408 W 1984-2013

206

LA-12503-MS KIVA-3:A KIVA Program with  

E-Print Network (OSTI)

. Gasoline ............................................................................ 35 b. Kerosene

207

Kerosene’s Price Impact on Air Travel Demand: A Cause-and-Effect Chain  

Science Journals Connector (OSTI)

This paper examines the impact of rising fuel prices on future air traffic. Using route and ... specific data the short-term impact of higher fuel prices on airline operating costs, passenger fares and ... advers...

Prof. Dr Richard Klophaus

2009-01-01T23:59:59.000Z

208

Tungsten and tungsten-alloy powder metallurgy: Powder production and applications-excluding lamps. November 1971-July 1989 (Citations from the US Patent data base). Report for November 1971-July 1989  

SciTech Connect

This bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys including various applications of these materials. The hydrogen reduction of tungsten compounds together with alloying-element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of various cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. Tungsten halogen lamps are examined in a separate bibliography. (Contains 60 citations fully indexed and including a title list.)

Not Available

1989-10-01T23:59:59.000Z

209

Geographic Area Month Aviation Gasoline Kerosene-Type Jet Fuel  

Gasoline and Diesel Fuel Update (EIA)

99.6 99.6 92.9 52.3 52.2 67.4 56.6 February ............................. 99.8 93.2 52.2 52.0 62.8 55.2 March .................................. 99.0 93.1 50.5 50.1 59.4 52.8 April .................................... 101.3 96.6 52.8 52.6 56.1 56.0 May ..................................... 105.8 102.2 55.0 54.7 51.7 57.7 June .................................... 106.4 101.6 53.2 53.1 54.9 53.2 July ..................................... 101.8 100.1 51.9 51.3 51.3 52.3 August ................................ 99.2 98.9 53.4 53.1 53.3 54.9 September .......................... 101.3 98.7 55.7 55.2 57.3 58.0 October ............................... 96.8 96.3 54.9 54.1 56.5 57.0 November ........................... 95.4 94.2 57.0 56.3 62.8 60.5 December ........................... 96.0 95.3 59.2 58.6

210

U.S. Sales of Kerosene by End Use  

U.S. Energy Information Administration (EIA) Indexed Site

Area: U.S. East Coast (PADD 1) New England (PADD 1A) Connecticut Maine Massachusetts New Hampshire Rhode Island Vermont Central Atlantic (PADD 1B) Delaware District of Columbia Maryland New Jersey New York Pennsylvania Lower Atlantic (PADD 1C) Florida Georgia North Carolina South Carolina Virginia West Virginia Midwest (PADD 2) Illinois Indiana Iowa Kansas Kentucky Michigan Minnesota Missouri Nebraska North Dakota Ohio Oklahoma South Dakota Tennessee Wisconsin Gulf Coast (PADD 3) Alabama Arkansas Louisiana Mississippi New Mexico Texas Rocky Mountain (PADD 4) Colorado Idaho Montana Utah Wyoming West Coast (PADD 5) Alaska Arizona California Hawaii Nevada Oregon Washington Period:

211

Prime Supplier Sales Volumes of Kerosene-Type Jet Fuel  

Gasoline and Diesel Fuel Update (EIA)

58,921.8 56,922.5 55,453.9 54,959.2 53,458.9 54,523.8 1983-2012 58,921.8 56,922.5 55,453.9 54,959.2 53,458.9 54,523.8 1983-2012 East Coast (PADD 1) 15,392.8 16,081.8 15,898.2 15,821.2 15,588.0 15,512.9 1983-2012 New England (PADD 1A) 1,279.6 1,525.1 1,132.7 1,146.9 1,177.7 1,153.8 1983-2012 Connecticut 204.6 192.9 153.5 157.1 W 181.0 1983-2012 Maine 175.6 141.7 134.2 161.7 132.7 125.2 1983-2012 Massachusetts 819.4 1,118 676.6 675.6 720.1 710.2 1983-2012 New Hampshire 15.1 15.4 W 62.0 64.1 38.8 1983-2012 Rhode Island 33.3 30.3 75.7 67.2 W W 1983-2012 Vermont 31.6 26.9 W 23.4 23.8 W 1983-2012 Central Atlantic (PADD 1B) 7,527.2 7,614.5 7,315.1 7,397.0 7,311.6 7,228.9 1983-2012 Delaware 11.2 11.9 8.7 10.1 10.0 14.1 1983-2012 District of Columbia - - - - - - 1983-2012

212

Geographic Area Month Aviation Gasoline Kerosene-Type Jet Fuel  

Gasoline and Diesel Fuel Update (EIA)

01.2 01.2 94.7 61.3 60.3 71.8 65.8 February ............................. 100.6 96.5 56.9 57.3 73.4 65.7 March .................................. 105.0 100.6 59.0 59.6 69.0 68.0 April .................................... 111.4 107.5 66.0 65.3 80.5 75.1 May ..................................... 114.4 110.0 63.3 62.2 68.4 66.1 June .................................... 113.5 107.0 57.7 57.5 58.5 59.8 July ..................................... 113.7 105.3 60.3 59.6 64.6 61.7 August ................................ 114.4 107.1 65.1 64.5 69.5 66.6 September .......................... 114.3 106.8 71.8 71.6 76.4 75.6 October ............................... 115.0 107.1 73.6 73.6 87.1 80.7 November ........................... 115.1 108.4 71.7 72.2 88.7 79.7 December ........................... 115.3

213

Prime Supplier Sales Volumes of Total Distillate and Kerosene  

U.S. Energy Information Administration (EIA) Indexed Site

158,110.5 153,279.5 150,543.5 150,826.0 154,151.9 151,155.6 158,110.5 153,279.5 150,543.5 150,826.0 154,151.9 151,155.6 1983-2013 East Coast (PADD 1) 45,616.9 39,584.9 37,386.4 37,249.3 38,108.9 40,198.6 1983-2013 New England (PADD 1A) 7,083.6 5,358.2 4,555.3 4,567.5 4,734.9 5,447.0 1983-2013 Connecticut 1,603.8 1,148.9 910.2 889.6 964.7 1,155.0 1983-2013 Maine 1,265.6 1,082.5 977.7 1,002.5 996.8 1,198.0 1983-2013 Massachusetts 2,233.0 1,639.5 1,372.6 1,377.2 1,415.8 1,509.8 1983-2013 New Hampshire 812.5 588.7 497.7 491.5 480.2 607.0 1983-2013 Rhode Island 656.7 518.7 450.0 478.7 499.4 548.0 1983-2013 Vermont 512.0 379.7 347.0 328.0 378.0 429.1 1983-2013 Central Atlantic (PADD 1B) 18,767.7 14,932.6 14,136.2 14,447.3 14,730.4 16,140.3 1983-2013 Delaware 259.8 215.9 200.5 302.1 236.3 296.3 1983-2013

214

Prime Supplier Sales Volumes of Distillate Fuel Oils and Kerosene...  

Gasoline and Diesel Fuel Update (EIA)

4,106.0 4,006.7 38,958.1 80,476.9 22,053.6 102,530.5 141,488.5 1,130.9 150,732.2 December ... 5,173.6 4,790.0 44,723.2 74,097.8 21,268.2...

215

Table 45. Refiner Volumes of Aviation Fuels, Kerosene, No. 1...  

Annual Energy Outlook 2012 (EIA)

145.8 461.3 48,876.2 13,893.0 268.5 3,966.8 391.5 3,072.0 3,773.6 35,832.0 December ... 138.2 466.6 49,701.7 14,199.8 342.2 4,861.0 599.8 3,200.2...

216

Geographic Area Month Aviation Gasoline Kerosene-Type Jet Fuel  

U.S. Energy Information Administration (EIA) Indexed Site

64.9 63.8 79.2 64.7 November ... 116.4 108.1 68.2 66.5 84.8 72.8 December ... 119.6 110.2 73.3 72.1 89.1 76.5 1999 Average...

217

Table 45. Refiner Volumes of Aviation Fuels, Kerosene, No. 1...  

Gasoline and Diesel Fuel Update (EIA)

... 64.5 101.3 12,742.5 2,029.5 190.8 2,042.2 12.7 38.0 91.2 4,874.9 December ... 57.1 89.7 13,275.8 2,017.6 210.4 2,595.6 26.2 58.1 112.5...

218

Prime Supplier Sales Volumes of Distillate Fuel Oils and Kerosene...  

U.S. Energy Information Administration (EIA) Indexed Site

6,760.2 5,346.9 52,887.5 75,799.8 21,654.3 97,454.1 150,341.6 1,882.4 164,331.1 February ... 4,728.6 3,460.9 46,281.0 77,949.8 20,779.4 98,729.2 145,010.2...

219

Ignition Delay Times of Kerosene(Jet-A)/Air Mixtures  

E-Print Network (OSTI)

Ignition of Jet-A/air mixtures was studied behind reflected shock waves. Heating of shock tube at temperature of 150 C was used to prepare a homogeneous fuel mixture. Ignition delay times were measured from OH emission at 309 nm and from absorption of He-Ne laser radiation at 3.3922 micrometers. The conditions behind shock waves were calculated by one-dimensional shock wave theory from initial conditions T1, P1, mixture composition and incident shock wave velocity. The ignition delay times were obtained at two fixed pressures 10, 20 atm for lean, stoichiometric and rich mixtures (ER=0.5, 1, 2) at an overall temperature range of 1040-1380 K.

Zhukov, V P; Starikovskii, A Yu

2012-01-01T23:59:59.000Z

220

U.S. Adjusted Sales of Kerosene by End Use  

U.S. Energy Information Administration (EIA) Indexed Site

Area: U.S. East Coast (PADD 1) New England (PADD 1A) Connecticut Maine Massachusetts New Hampshire Rhode Island Vermont Central Atlantic (PADD 1B) Delaware District of Columbia Maryland New Jersey New York Pennsylvania Lower Atlantic (PADD 1C) Florida Georgia North Carolina South Carolina Virginia West Virginia Midwest (PADD 2) Illinois Indiana Iowa Kansas Kentucky Michigan Minnesota Missouri Nebraska North Dakota Ohio Oklahoma South Dakota Tennessee Wisconsin Gulf Coast (PADD 3) Alabama Arkansas Louisiana Mississippi New Mexico Texas Rocky Mountain (PADD 4) Colorado Idaho Montana Utah Wyoming West Coast (PADD 5) Alaska Arizona California Hawaii Nevada Oregon Washington Period:

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Prime Supplier Sales Volumes of Kerosene-Type Jet Fuel  

U.S. Energy Information Administration (EIA) Indexed Site

58,386.8 57,380.8 57,511.7 61,022.4 59,252.0 55,062.2 1983-2013 58,386.8 57,380.8 57,511.7 61,022.4 59,252.0 55,062.2 1983-2013 East Coast (PADD 1) 18,284.2 16,437.1 16,943.8 16,884.2 16,412.3 14,287.5 1983-2013 New England (PADD 1A) 1,211.3 1,172.2 1,228.4 1,207.8 1,432.6 1,121.1 1983-2013 Connecticut 212.1 202.7 207.0 164.4 246.4 169.3 1983-2013 Maine 115.8 127.2 131.1 141.6 144.0 137.8 1983-2013 Massachusetts 738.4 705.5 738.7 743.0 863.8 670.3 1983-2013 New Hampshire 37.4 29.5 35.2 41.8 50.6 44.1 1983-2013 Rhode Island 88.5 W 89.9 89.9 99.2 76.9 1983-2013 Vermont 19.1 W 26.5 27.0 28.7 22.7 1983-2013 Central Atlantic (PADD 1B) 9,320.4 7,996.8 8,594.9 8,104.5 8,284.9 7,114.1 1983-2013 Delaware W W W W W W 1983-2013 District of Columbia W W W W W W 1983-2013

222

Das Prfzentrum Carsten Lampe, Daniel Eggert,  

E-Print Network (OSTI)

Kalibrierlaboratorien" · Qualitätswesen analog den Anforderungen der ISO 9001 z.B. Sensorkalibriersystem / Dokumentation Prüfinstitut (durch DGWK, heute DIN CERTCO) · Seit 2003 ISO/IEC 17025 akkreditiert · Seit 2003 Prüfungen und;4 Was verlangt die Akkreditierung? ISO IEC 17025 ,,Allgemeine Anforderungen an die Kompetenz von Prüf- und

223

Max Tech and Beyond: Fluorescent Lamps  

E-Print Network (OSTI)

contain one or more rare earth elements in their chemicalcomposition. The rare earth elements are a collection of

Scholand, Michael

2012-01-01T23:59:59.000Z

224

Covered Product Category: Compact Fluorescent Lamps | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

per watt performance. Buyer Tips CFLs installed in enclosed fixtures designed for incandescent bulbs may overheat. This can significantly reduce both light output and lifetime....

225

U.S. Adjusted Distillate Fuel Oil and Kerosene Sales by End Use  

U.S. Energy Information Administration (EIA) Indexed Site

Area: U.S. East Coast (PADD 1) New England (PADD 1A) Connecticut Maine Massachusetts New Hampshire Rhode Island Vermont Central Atlantic (PADD 1B) Delaware District of Columbia Maryland New Jersey New York Pennsylvania Lower Atlantic (PADD 1C) Florida Georgia North Carolina South Carolina Virginia West Virginia Midwest (PADD 2) Illinois Indiana Iowa Kansas Kentucky Michigan Minnesota Missouri Nebraska North Dakota Ohio Oklahoma South Dakota Tennessee Wisconsin Gulf Coast (PADD 3) Alabama Arkansas Louisiana Mississippi New Mexico Texas Rocky Mountain (PADD 4) Colorado Idaho Montana Utah Wyoming West Coast (PADD 5) Alaska Arizona California Hawaii Nevada Oregon Washington Period:

226

U.S. Distillate Fuel Oil and Kerosene Sales by End Use  

U.S. Energy Information Administration (EIA) Indexed Site

Area: U.S. East Coast (PADD 1) New England (PADD 1A) Connecticut Maine Massachusetts New Hampshire Rhode Island Vermont Central Atlantic (PADD 1B) Delaware District of Columbia Maryland New Jersey New York Pennsylvania Lower Atlantic (PADD 1C) Florida Georgia North Carolina South Carolina Virginia West Virginia Midwest (PADD 2) Illinois Indiana Iowa Kansas Kentucky Michigan Minnesota Missouri Nebraska North Dakota Ohio Oklahoma South Dakota Tennessee Wisconsin Gulf Coast (PADD 3) Alabama Arkansas Louisiana Mississippi New Mexico Texas Rocky Mountain (PADD 4) Colorado Idaho Montana Utah Wyoming West Coast (PADD 5) Alaska Arizona California Hawaii Nevada Oregon Washington Period:

227

Kerosene-Type Jet Fuel Sales to End Users Refiner Sales Volumes  

Gasoline and Diesel Fuel Update (EIA)

2007 2008 2009 2010 2011 2012 View 2007 2008 2009 2010 2011 2012 View History U.S. 40,136.3 39,913.9 37,954.6 34,775.2 33,272.0 32,545.7 1983-2012 East Coast (PADD 1) 9,039.8 9,693.3 9,041.1 8,730.4 7,785.9 6,813.2 1983-2012 New England (PADD 1A) 606.3 930.0 766.0 790.7 679.4 373.7 1983-2012 Connecticut 171.1 W W W W W 1983-2012 Maine W W W W W W 1983-2012 Massachusetts W W W W 495.6 189.3 1983-2012 New Hampshire W W W W W - 1983-2012 Rhode Island W W W W W W 1983-2012 Vermont W W - - - W 1983-2012 Central Atlantic (PADD 1B) 4,645.2 4,946.6 5,127.5 4,696.7 3,983.7 3,569.8 1983-2012 Delaware W - - W - - 1983-2012 District of Columbia - - - - - - 1983-2012 Maryland W 209.8 210.3 190.8 177.5 W 1983-2012 New Jersey 1,463.5 1,555.6 2,006.2 1,922.4 1,913.2 1,646.2 1983-2012

228

Table 45. Refiner Volumes of Aviation Fuels, Kerosene, No. 1 Distillate,  

Gasoline and Diesel Fuel Update (EIA)

34.7 34.7 428.4 46,539.7 12,728.4 790.3 6,200.2 648.4 4,283.7 3,323.4 44,204.9 February ......................... 151.1 456.7 46,811.8 13,168.9 661.0 5,865.0 639.0 3,498.4 4,030.8 40,811.0 March .............................. 155.1 534.1 47,764.0 11,796.0 685.4 3,081.1 347.2 1,274.9 2,912.8 32,094.6 April ................................ 181.4 632.9 48,092.4 12,418.7 309.0 1,382.4 162.4 425.7 2,671.8 27,292.6 May ................................. 194.0 730.2 48,978.1 11,174.4 288.0 868.9 122.3 240.3 2,628.8 22,213.6 June ................................ 184.4 739.6 50,091.3 10,034.5 424.7 571.0 151.7 314.2 2,237.4 23,117.3 July ................................. 205.9 830.4 50,287.4 11,139.2 226.4 714.5 145.1 261.5 2,057.6 25,037.3 August ............................ 200.2 854.8 50,327.4 11,706.4 202.7 1,112.1

229

Table A2. Refiner/Reseller Prices of Aviation Fuels, Propane, and Kerosene,  

Gasoline and Diesel Fuel Update (EIA)

PAD District I 1983 ...................................... 127.8 123.0 87.0 87.8 91.3 52.8 94.5 90.1 1984 ...................................... 124.7 119.5 83.5 85.0 93.3 50.9 106.0 92.2 1985 ...................................... 121.4 115.3 78.5 82.2 91.5 44.9 104.9 88.1 1986 ...................................... 100.6 91.8 52.8 52.2 86.0 32.7 81.0 61.6 1987 ...................................... 90.9 85.0 54.1 55.6 82.3 31.0 78.1 58.9 1988 ...................................... 89.5 82.9 51.2 51.3 84.8 29.8 73.3 55.3 1989 ...................................... 99.2 92.2 59.1 60.1 75.8 29.2 69.3 67.2 1990 ...................................... 112.3 105.3 75.9 78.3 91.8 45.0 86.4 84.4 1991 ...................................... 105.6 100.3 65.3 67.2 W 40.5 81.0 74.0 1992 ......................................

230

Table 45. Refiner Volumes of Aviation Fuels, Kerosene, No. 1 Distillate,  

Gasoline and Diesel Fuel Update (EIA)

4.2 4.2 406.0 45,968.1 11,079.0 534.5 5,366.3 833.9 4,675.6 3,248.9 44,872.7 February ......................... 146.6 499.8 47,800.3 10,256.4 357.8 3,591.8 621.7 2,731.9 3,684.2 38,357.8 March .............................. 150.3 518.6 48,152.6 10,316.6 365.5 2,056.1 336.2 1,114.2 3,284.7 28,091.6 April ................................ 171.8 592.8 49,135.3 9,493.8 287.9 1,335.2 199.7 438.4 3,352.9 25,786.2 May ................................. 172.2 665.1 49,770.4 9,886.7 249.2 1,017.4 176.2 314.9 2,935.6 24,783.5 June ................................ 175.3 759.4 52,048.3 10,834.1 192.7 754.0 194.4 360.2 2,313.9 24,285.6 July ................................. 239.2 853.3 51,725.7 10,840.4 136.7 1,348.8 199.7 362.4 2,083.2 26,581.1 August ............................ 201.6 810.9 52,026.8 12,609.7 241.1 1,226.9

231

Prices of Refiner Kerosene-Type Jet Fuel Sales to End Users  

U.S. Energy Information Administration (EIA) Indexed Site

2.922 2.787 2.813 2.908 3.002 3.040 1975-2013 2.922 2.787 2.813 2.908 3.002 3.040 1975-2013 East Coast (PADD 1) 2.907 2.783 2.825 2.919 3.028 3.055 1983-2013 New England (PADD 1A) W W W 2.973 3.085 3.129 1983-2013 Connecticut W W W W W W 1984-2013 Maine W W W W W W 1984-2013 Massachusetts W W W W W W 1984-2013 New Hampshire - - - W - - 1984-2013 Rhode Island W W W W W W 1984-2013 Vermont - - - - - - 1984-2013 Central Atlantic (PADD 1B) 2.899 2.763 2.816 2.904 3.011 3.043 1983-2013 Delaware - - - - - - 1984-2013 District of Columbia - - - - - - 1984-2013 Maryland W W W W W W 1984-2013 New Jersey 2.881 2.748 2.805 2.895 3.003 3.038 1984-2013 New York 2.930 2.788 2.830 W W W 1984-2013 Pennsylvania 2.906 2.766 2.852 2.908 3.018 3.020 1984-2013

232

Table A2. Refiner/Reseller Prices of Aviation Fuels, Propane, and Kerosene,  

Gasoline and Diesel Fuel Update (EIA)

PAD District I 1983 ...................................... 127.8 123.0 87.0 87.8 91.3 52.8 94.5 90.1 1984 ...................................... 124.7 119.5 83.5 85.0 93.3 50.9 106.0 92.2 1985 ...................................... 121.4 115.3 78.5 82.2 91.5 44.9 104.9 88.1 1986 ...................................... 100.6 91.8 52.8 52.2 86.0 32.7 81.0 61.6 1987 ...................................... 90.9 85.0 54.1 55.6 82.3 31.0 78.1 58.9 1988 ...................................... 89.5 82.9 51.2 51.3 84.8 29.8 73.3 55.3 1989 ...................................... 99.2 92.2 59.1 60.1 75.8 29.2 69.3 67.2 1990 ...................................... 112.3 105.3 75.9 78.3 91.8 45.0 86.4 84.4 1991 ...................................... 105.6 100.3 65.3 67.2 W 40.5 81.0 74.0 1992 ......................................

233

Table 50. Prime Supplier Sales Volumes of Distillate Fuel Oils and Kerosene  

Gasoline and Diesel Fuel Update (EIA)

048.9 048.9 3,882.7 43,253.5 78,544.5 20,983.0 99,527.5 142,781.0 1,215.1 152,927.6 February ............................. 4,331.5 2,419.0 42,453.9 81,957.0 20,781.0 102,737.9 145,191.8 1,145.6 153,087.9 March .................................. 3,374.8 1,616.3 38,313.8 87,940.5 21,866.1 109,806.6 148,120.5 1,062.2 154,173.8 April .................................... 1,699.2 728.2 28,122.4 90,081.2 20,288.6 110,369.8 138,492.2 639.3 141,558.9 May ..................................... 1,294.6 643.7 22,565.9 88,582.4 20,702.3 109,284.6 131,850.5 482.9 134,271.8 June .................................... 1,675.6 579.4 23,580.9 96,532.1 21,436.8 117,968.9 141,549.8 385.0 144,189.9 July ..................................... 1,577.3 605.1 22,198.4 92,096.8 21,709.0 113,805.8 136,004.2 656.0 138,842.6

234

Prime Supplier Sales Volumes of Distillate Fuel Oils and Kerosene by PAD District and State  

Gasoline and Diesel Fuel Update (EIA)

7,583.7 7,583.7 5,086.5 57,988.5 72,118.7 20,784.9 92,903.6 150,892.1 2,271.3 165,833.6 February ............................. 7,190.5 4,192.4 55,685.0 76,234.8 22,030.8 98,265.6 153,950.6 2,265.8 167,599.4 March .................................. 3,741.4 1,832.9 42,789.1 78,746.7 20,513.7 99,260.4 142,049.5 1,644.7 149,268.5 April .................................... 1,759.1 694.2 33,643.2 85,180.7 21,967.4 107,148.0 140,791.2 1,157.8 144,402.3 May ..................................... 1,029.0 473.8 25,651.8 83,213.2 21,779.5 104,992.8 130,644.5 661.5 132,808.8 June .................................... 1,148.6 527.8 23,238.7 83,513.2 21,394.3 104,907.5 128,146.2 536.4 130,359.0 July ..................................... 868.0 541.3 22,987.0 82,742.6 20,917.3 103,659.8 126,646.8 517.0 128,573.1

235

Kerosene-Type Jet Fuel Sales to End Users Refiner Sales Volumes  

U.S. Energy Information Administration (EIA) Indexed Site

33,033.1 32,893.1 32,452.7 33,281.4 32,532.8 30,000.3 1983-2013 33,033.1 32,893.1 32,452.7 33,281.4 32,532.8 30,000.3 1983-2013 East Coast (PADD 1) 8,170.7 7,484.8 7,317.4 7,494.1 7,085.1 5,550.5 1983-2013 New England (PADD 1A) W W W 337.4 390.2 279.7 1983-2013 Connecticut W W W W W W 1984-2013 Maine W W W W W W 1984-2013 Massachusetts W W W W W W 1984-2013 New Hampshire - - - W - - 1984-2013 Rhode Island W W W W W W 1984-2013 Vermont - - - - - - 1984-2013 Central Atlantic (PADD 1B) 4,254.7 4,171.6 4,469.2 4,834.6 4,713.8 3,787.7 1983-2013 Delaware - - - - - - 1984-2013 District of Columbia - - - - - - 1984-2013 Maryland W W W W W W 1984-2013 New Jersey 2,477.5 2,444.1 2,660.1 2,524.8 2,448.5 1,789.9 1984-2013 New York 1,435.8 1,430.6 1,480.5 W W W 1984-2013

236

Table A2. Refiner/Reseller Prices of Aviation Fuels, Propane, and Kerosene,  

Gasoline and Diesel Fuel Update (EIA)

PAD District I 1983 ...................................... 127.8 123.0 87.0 87.8 91.3 52.8 94.5 90.1 1984 ...................................... 124.7 119.5 83.5 85.0 93.3 50.9 106.0 92.2 1985 ...................................... 121.4 115.3 78.5 82.2 91.5 44.9 104.9 88.1 1986 ...................................... 100.6 91.8 52.8 52.2 86.0 32.7 81.0 61.6 1987 ...................................... 90.9 85.0 54.1 55.6 82.3 31.0 78.1 58.9 1988 ...................................... 89.5 82.9 51.2 51.3 84.8 29.8 73.3 55.3 1989 ...................................... 99.2 92.2 59.1 60.1 75.8 29.2 69.3 67.2 1990 ...................................... 112.3 105.3 75.9 78.3 91.8 45.0 86.4 84.4 1991 ...................................... 105.6 100.3 65.3 67.2 W 40.5 81.0 74.0 1992 ......................................

237

Prices of Refiner Kerosene-Type Jet Fuel Sales to End Users  

Gasoline and Diesel Fuel Update (EIA)

2007 2008 2009 2010 2011 2012 View 2007 2008 2009 2010 2011 2012 View History U.S. 2.165 3.052 1.704 2.201 3.054 3.104 1978-2012 East Coast (PADD 1) 2.161 3.068 1.707 2.201 3.064 3.126 1983-2012 New England (PADD 1A) 2.224 3.113 1.737 2.216 3.098 3.179 1983-2012 Connecticut 2.222 W W W W W 1983-2012 Maine W W W W W W 1983-2012 Massachusetts W W W W 3.088 3.154 1983-2012 New Hampshire W W W W W - 1983-2012 Rhode Island W W W W W W 1983-2012 Vermont W W - - - W 1983-2012 Central Atlantic (PADD 1B) 2.158 3.080 1.694 2.192 3.060 3.116 1983-2012 Delaware W - - W - - 1983-2012 District of Columbia - - - - - - 1983-2012 Maryland 2.151 2.962 1.645 2.198 3.039 W 1983-2012 New Jersey 2.106 3.014 1.684 2.182 3.050 3.105 1983-2012

238

Extraction of naphthenic acid from kerosene using porous and nonporous polymeric membranes  

SciTech Connect

A systematic study of membrane-assisted extraction of naphthenic acids from hydrocarbon fractions by aqueous caustic soda using both porous and nonporous membranes is reported. The effects of hydrodynamic factors, concentration of naphthenic acids and caustic soda, and temperature on the transmembrane flux are discerned. The film model is used to determine the intrinsic mass transfer characteristics of the membranes.

Netke, S.A.; Pangarkar, V.G. [Univ. of Bombay, Matunga (India)

1996-01-01T23:59:59.000Z

239

,"U.S. Total Adjusted Distillate Fuel Oil and Kerosene Sales...  

U.S. Energy Information Administration (EIA) Indexed Site

"KD0VABNUS1","KPRVABNUS1" "Date","U.S. Total Distillate Adj SalesDeliveries to Vessel Bunker Consumers (Thousand Gallons)","U.S. Residual Fuel Oil Adj SalesDeliveries to Vessel...

240

NOPM and Availability of Framework Document for HID Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

8:48 Feb 27, 2012 8:48 Feb 27, 2012 Jkt 226001 PO 00000 Frm 00008 Fmt 4702 Sfmt 4702 E:\FR\FM\28FEP1.SGM 28FEP1 mstockstill on DSK4VPTVN1PROD with PROPOSALS Federal Register / Vol. 77, No. 39 / Tuesday, February 28, 2012 / Proposed Rules 11785 collections for particular program, except where required by statute. III. Questions for Comment The list below includes the questions about these reform ideas that address issues which are of greatest interest to OMB at this stage of the process. Comments addressing any other concerns, and other types of feedback, are also welcome. In addition, as was explained at the beginning of this notice, the public comments received by OMB will be posted on OMB's Web site and at http:// www.regulations.gov. Accordingly, please do not include in your comments

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1988. The private sector in Brazil owned (in 1986) 40% ofElectricity Conservation in Brazil: Potential and Pro-electricity consumption in Brazil's residential sector was

Gadgil, A.J.

2008-01-01T23:59:59.000Z

242

Ancient Lamps, Earrings Yield Their Secrets Under Neutron Imaging...  

NLE Websites -- All DOE Office Websites (Extended Search)

a colonial-period plantation in Rhode Island. The samples include artifacts from daily life: a clothing buckle, a knife, and some building hardware. One circular object from...

243

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

also additional benefits from avoided costs of environmentalpremium for India)) - (avoided annual cost of incandescents)electricity) + (avoided annual cost of incandescents) - (

Gadgil, A.J.

2008-01-01T23:59:59.000Z

244

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

Schultz, W.N.; Thomas, R.J.

1999-08-31T23:59:59.000Z

245

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

demonstration (like street lights) and commercialization andthe dominant light source for street and roadway lighting,has been a popular light source for street lighting because

Scholand, Michael

2012-01-01T23:59:59.000Z

246

LED Performance Specification Series: T8 Replacement Lamps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

program of SSL research, development, and commercialization. For Program Information: Kelly Gordon Pacific Northwest National Laboratory Phone: (503) 417-7558 E-mail:...

247

Photo-Polarography with a Flash-Lamp  

Science Journals Connector (OSTI)

... PHOTO-POLAROGRAPHY, originating from the synthesis of ... -POLAROGRAPHY, originating from the synthesis of photo-chemistry and polarography, records photokinetic-currents caused by ...

H. BERG; H. SCHWEISS

1961-09-23T23:59:59.000Z

248

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1.7% of in- stalled hydroelectric capacity. Op. cit. ref [in Ig86) based on hydroelectric generation, and most of thethe still abundant hydroelectric potential of the country.

Gadgil, A.J.

2008-01-01T23:59:59.000Z

249

Apparatus to facilitate lengthening the life of incandescent lamps  

SciTech Connect

An energizing circuit is described for an incandescent bulb comprising a transformer having a primary winding connectable to an AC mains source and first and second secondary windings for producing first and second voltages. The first secondary winding is connected to an input of a first full-wave rectifier means and the second secondary winding is connected to an input of a second full-wave rectifier means, the full-wave rectifier means having outputs connected in parallel across the bulb. The first voltage is sufficient to fully illuminate the bulb and the second voltage is sufficient to maintain the bulb warm but with little or no light output, a first switch being connected between the first secondary winding and the first rectifier means whereby, when the first switch is open, the bulb is energized solely by the second voltage.

Spissinger, F.H.

1987-03-17T23:59:59.000Z

250

Series Resonant Inverter with Contactless Transformers for Multiple LED Lamps.  

E-Print Network (OSTI)

??A half-bridge series-resonant inverter adopted to realize the quasi current source and the constant current source with a number of contactless transformers in series for… (more)

Cheng, Shuen-Wen

2013-01-01T23:59:59.000Z

251

Solid-State Lighting on a Shoestring Budget: The Economics of Off-Grid Lighting for Small Businesses in Kenya  

SciTech Connect

superior lighting services to low income people in off-grid areas of developing countries, many of whom currently rely on fuel based lighting sources such as kerosene. If this potential is to be achieved in the near term, however, manufacturers must produce off-grid lighting products that are inexpensive, perform well, and meet the needs of potential end users. At present, relatively few products meet all three of these goals. In this article, we report results from a detailed study of lighting use by micro-enterprises in two small towns in Kenya's Rift Valley Province. The work included a survey about lighting use by 50 small businesses, careful measurements of kerosene lighting use patterns and associated costs for 23 of these businesses, and a subsequent field trial in which 14 of the 23 businesses purchased and used low cost LED lamps over a number of months.

Radecsky, Kristen; Johnstone, Peter; Jacobson, Arne; Mills, Evan

2008-12-14T23:59:59.000Z

252

Identifying Options for Deep Reductions in Greenhouse Gas Emissions from California Transportation: Meeting an 80% Reduction Goal in 2050  

E-Print Network (OSTI)

Instate Gasoline Jet Fuel (kerosene) Biofuels HydrogenOverall Gasoline Jet Fuel (kerosene) Biofuels Hydrogen MJ/Instate Gasoline Jet Fuel (kerosene) Biofuels Hydrogen

Yang, Christopher; McCollum, David L; McCarthy, Ryan; Leighty, Wayne

2008-01-01T23:59:59.000Z

253

Inventory of China's Energy-Related CO2 Emissions in 2008  

E-Print Network (OSTI)

kerosene other kerosene shale oil gas/diesel oil residualbituminous coal lignite oil shale other petroleum products (

Fridley, David

2011-01-01T23:59:59.000Z

254

Power Capture (PowCap) Board for Non Intrusive Load Monitoring and Power Line Communication Exploration and Development  

E-Print Network (OSTI)

including a) LED lamp, b) incandescent lamp, c) Macbook Pro,W) a LED Lamp 15W b Incandescent Lamp 25W c Macbook 200W dLED lamp (LED) from the incandescent lamp (Lamp) and the Fan

Balakrishnan, Vikram

2013-01-01T23:59:59.000Z

255

L&E: Refrigerated Display Case | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Adopt the Lighting & Electrical » Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs The LED Refrigerated Display Case Lighting Specification delivers nearly 50% energy savings compared to typical display case lighting. If all retail refrigerated display cases switched today to LED systems, over 2.1 TWh of electricity could be saved annually. LED Refrigerated Display Case Lighting Specification

256

L&E: Participate in a field test for high-efficiency troffer lighting. |  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Participate Lighting & Electrical » Participate in a field test for high efficiency troffer lighting Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Participate in a field test for high-efficiency troffer lighting 50% of all commercial fluorescent lighting fixtures are recessed troffers in 1'x4', 2'x2' and 2'x4' configurations, in operation for more than 10 hours a day on average and collectively consuming more than 87 TWh of electricity annually. The Lighting & Electrical team supported the market introduction of high-efficiency troffers by developing a specification that allows for

257

L&E - high efficiency lighting for parking structure | The Better Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

structure structure Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking structure Parking structures and garages are typically lighted by older HID lighting technology without any energy-saving controls. The latest high-efficiency alternatives with energy-saving controls-including light-emitting diode (LED), induction, and fluorescent technology options-can save building owners over 40% on their parking lot lighting bills while delivering additional benefits such as better-lighted spaces. The Lighting & Electrical team developed a performance specification that

258

L&E: Adopt high-efficiency lighting for your parking lot | The Better  

NLE Websites -- All DOE Office Websites (Extended Search)

lot lot Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking lot Most parking lots are illuminated by older high-intensity discharge (HID) lighting technology without any energy-saving controls. New light-emitting diode (LED) technology can cut parking lot lighting energy bills by 40%, or much more with controls, while delivering additional benefits including long life, reduced maintenance costs, and improved lighting uniformity. The Lighting & Electrical team developed a performance specification to help building owners take advantage of these improved lighting

259

Spatial and time-dependent distribution of plasma parameters in the metal-halide arc lamp  

E-Print Network (OSTI)

It was shown by several authors that closed high pressure arc a.c. discharge in mercury vapors with addition of metal halide cannot be described in frames of the local thermodynamic equilibrium (LTE) model. However some plasma parameters (electron and high lying excited states densities as well as Hg metastable levels densities) are assumed to be in equilibrium with electron temperature and these assumptions are applied in plasma diagnostics. To verify these supposition the method of local plasma spectroscopy based on spatial and temporal distribution of spectral line profiles was developed. The experimental set up is based on diffraction spectrometer with large aperture, spatial scanning device and photodetector, which allows to carry out the measurements in chosen phases of current period. The software for data acquisition and processing is based on LabVIEW system. The original method of joint data processing was applied to data arrays containing spatial, spectral and temporal distribution of a source surfa...

Khakhaev, A; Ekimov, K; Soloviev, A; Khakhaev, Anatoly; Luizova, Lidia; Ekimov, Konstantin; Soloviev, Alexey

2004-01-01T23:59:59.000Z

260

E-LAMP: integration of innovative ideas for multimedia event detection  

Science Journals Connector (OSTI)

Detecting multimedia events in web videos is an emerging hot research area in the fields of multimedia and computer vision. In this paper, we introduce the core methods and technologies of the framework we developed recently for our Event Labeling through ... Keywords: Multimedia content analysis, Multimedia event detection

Wei Tong; Yi Yang; Lu Jiang; Shoou-I Yu; Zhenzhong Lan; Zhigang Ma; Waito Sze; Ehsan Younessian; Alexander G. Hauptmann

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Side-by-Side Testing of Commercial Office Lighting Systems: Two-lamp Fluorescent Fixtures  

E-Print Network (OSTI)

. Guide to Performance Evaluation of Efficient Lighting Products, Lighting Research Center, Rensselaer Polytechnic Institute, Troy, NY. IES, 1987. IES Lighting Handbook: 1987 Ap~lications Volume, Illuminating Engineering Society of North America, New... Transactions on Industrv A~plications, No. 5, pp. 1189-1 197. Verderber, R.R. and Rubinstein, F.M. and Ward, G., 1989. Photoelectric Control of Daylight Following Lighting Systems, CU- 6243, Electric Power Research Institute, Palo Alto, CA. Rubinstein, F...

Parker, D. S.; Schrum, L.; Sonne, J. K.; Stedman, T. C.

1996-01-01T23:59:59.000Z

262

Contribution to the numerical study of turbulence in high intensity discharge lamps  

SciTech Connect

We present in this paper a comparison between results obtained with a laminar and turbulent models for high-pressure mercury arc. The two models are based on the resolution of bidimensional time-dependent equations by a semi-implicit finite-element code. The numerical computation of turbulent model is solved with large eddy simulation model; this approach takes into account the various scales of turbulence by a filtering method on each scale. The results show the quantitative influence of turbulence on the flow fields and also the difference between laminar and turbulent effects on the dynamic thermal behaviour and on the characteristics of the discharge.

Kaziz, S.; Ben Ahmed, R.; Helali, H.; Gazzah, H.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-07-15T23:59:59.000Z

263

Low Frequency Architecture for Multi-Lamp CCFL Systemswith Capacitive Ignition  

E-Print Network (OSTI)

uniformity degradation, and electromagnetic interference (EMI). The architecture i s capable of driving

264

Market Research on the Use of Energy Saving Lamps: The DELight Project  

Science Journals Connector (OSTI)

This paper describes the DELight project. DELight is studying European domestic lighting and the potential for energy-efficient lighting in terms of the technology, aesthetics and behaviour.

Agneta Persson

1999-01-01T23:59:59.000Z

265

Report 20.4: Lumen and Chromaticity Maintenance of LED PAR38 Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy (DOE) CALiPER program has been purchasing and testing general illumination solid-state lighting (SSL) products since 2006. CALiPER relies on standardized photometric testing (following the Illuminating Engineering Society of North America [IES] approved method LM-79-081) conducted by accredited, independent laboratories. Results from CALiPER testing are available to the public via detailed reports for each product or through summary reports, which assemble data from several product tests and provide comparative analyses. Increasingly, CALiPER investigations also rely on new test procedures that are not industry standards; these experiments provide data that is essential for understanding the most current issues facing the SSL industry.

266

Solid-state lighting : lamp targets and implications for the semiconductor chip.  

SciTech Connect

A quiet revolution is underway. Over the next 5-10 years inorganic-semiconductor-based solid-state lighting technology is expected to outperform first incandescent, and then fluorescent and high-intensity-discharge, lighting. Along the way, many decision points and technical challenges will be faced. To help understand these challenges, the U.S. Department of Energy, the Optoelectronics Industry Development Association and the National Electrical Manufacturers Association recently updated the U.S. Solid-State Lighting Roadmap. In the first half of this paper, we present an overview of the high-level targets of the inorganic-semiconductor part of that update. In the second half of this paper, we discuss some implications of those high-level targets on the GaN-based semiconductor chips that will be the 'engine' for solid-state lighting.

Tsao, Jeffrey Yeenien

2003-08-01T23:59:59.000Z

267

E-Print Network 3.0 - antigen-dc-lamp messenger rna-electroporated...  

NLE Websites -- All DOE Office Websites (Extended Search)

Virus Research 102 (2004) 5964 RNA interference against retroviruses Summary: Viral gene HIV-1 Tat, Rev siRNA transfection, siRNA electroporation 293T, Jurkat, PBMC Coburn and...

268

E-Print Network 3.0 - ave lamp margareete Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Medicine 9 GortnerAve.. Buford Ave. Summary: GortnerAve.. Buford Ave. UnderwoodST. Dan Patch Ave. Directions to Gortner Ave Ramp From I-94... Eastbound 1. Exit at Snelling Ave....

269

Mines and Quarries: The Coal and Other Mines (Safety -Lamps and Lighting) Order, 1956   

E-Print Network (OSTI)

This order is made under the Mines and Quarries Act, 1954, s. 190, which empowers the Minister of Fuel and Power to re-enact (to the extent to which they could be enacted in regulations made under the Act and subject to modifications of the kind...

Her Majesty's Stationary Office

1960-01-01T23:59:59.000Z

270

Embodied Energy and Off-Grid Lighting  

SciTech Connect

The greenhouse gas (GHG) emissions from fuel-based lighting are substantial given the paltry levels of lighting service provided to users, leading to a great opportunity for GHG mitigation byencouraging the switch from fuel-based to rechargeable LED lighting. However, as with most new energy technology, switching to efficient lighting requires an up-front investment of energy(and GHGs) embedded in the manufacture of replacement components. We studied a population of off-grid lighting users in 2008-2009 in Kenya who were given the opportunity to adopt LEDlighting. Based on their use patterns with the LED lights and the levels of kerosene offset we observed, we found that the embodied energy of the LED lamp was"paid for" in only one month for grid charged products and two months for solar charged products. Furthermore, the energyreturn-on investment-ratio (energy produced or offset over the product's service life divided by energy embedded) for off-grid LED lighting ranges from 12 to 24, which is on par with on-gridsolar and large-scale wind energy. We also found that the energy embodied in the manufacture of a typical hurricane lantern is about one-half to one-sixth of that embodied in the particular LEDlights that we evaluated, indicating that the energy payback time would be moderately faster if LEDs ultimately displace the production of kerosene lanterns. As LED products improve, weanticipate longer service lives and more successful displacement of kerosene lighting, both of which will speed the already rapid recovery of embodied energy in these products. Our studyprovides a detailed appendix with embodied energy values for a variety of components used to construct off-grid LED lighting, which can be used to analyze other products.

Alstone, Peter; Mills, Evan; Jacobson, Arne

2011-01-25T23:59:59.000Z

271

Environmental Energy Technologies Division News  

NLE Websites -- All DOE Office Websites (Extended Search)

0: 0: Vol. 9, No. 2 Driving Demand Bennett-Nordman IEEE Standard Nicotine and Ozone SVOW Renewables Portfolio Standard Report Kerosene Lamp Particulate Study Research Highlights Sources and Credits PDF of EETD News Homeowner Motivations for Energy Efficiency Improvements Driving Demand report cover Hundreds of millions of dollars in public money are supporting home energy efficiency improvements. Researchers at the Lawrence Berkeley National Laboratory's (Berkeley Lab) Environmental Energy Technologies Division (EETD) are helping to ensure that these funds have their maximum impact with a new report that examines what motivates homeowners to seek out home energy improvements. "Convincing millions of Americans to divert their time and resources into upgrading their homes to eliminate energy waste, avoid high utility bills,

272

Environmental Energy Technologies Division News  

NLE Websites -- All DOE Office Websites (Extended Search)

9, No. 2 [http://eetd.lbl.gov/newsletter/nl33/] 9, No. 2 [http://eetd.lbl.gov/newsletter/nl33/] Environmental Energy Technologies Division News [http://eetd.lbl.gov/newsletter/] © 2010 Environmental Energy Technologies Division [http://eetd.lbl.gov/] E.O. Lawrence Berkeley National Laboratory [http://www.lbl.gov/] Disclaimer [http://www.lbl.gov/Disclaimers.html] FALL NEWSLETTER: VOL. 9, NO. 2 Driving Demand Bennett-Nordman IEEE Standard Nicotine and Ozone SVOW Renewables Portfolio Standard Report Kerosene Lamp Particulate Study Research Highlights Sources and Credits New ways of convincing homeowners of the benefits of energy efficiency improvements to their homes-and new language to use in discussing these benefits-is discussed in a report titled "Driving Demand" from Environmental Energy Technologies Division researchers. This issue also

273

Workbook Contents  

U.S. Energy Information Administration (EIA) Indexed Site

"KDRVTESCA1","KDRVTESHI1","KDRVTESNV1","KDRVTESOR1","KDRVTESWA1" "Date","U.S. Kerosene Retail Deliveries (Thousand Gallons)","East Coast (PADD 1) Kerosene Retail Deliveries...

274

Workbook Contents  

U.S. Energy Information Administration (EIA) Indexed Site

EPPKPWGSNVDPG","EMAEPPKPWGSORDPG","EMAEPPKPWGSWADPG" "Date","U.S. Kerosene WholesaleResale Price by Refiners (Dollars per Gallon)","East Coast (PADD 1) Kerosene...

275

untitled  

Annual Energy Outlook 2012 (EIA)

by PAD District, 1983-Present (Cents per Gallon Excluding Taxes) - Continued Geographic Area Year Aviation Gasoline Kerosene-Type Jet Fuel Propane Kerosene Sales to End Users...

276

X:\\Data_Publication\\Pma\\current\\ventura\\pma00.vp  

Annual Energy Outlook 2012 (EIA)

by PAD District, 1983-Present (Cents per Gallon Excluding Taxes) - Continued Geographic Area Year Aviation Gasoline Kerosene-Type Jet Fuel Propane Kerosene Sales to End Users...

277

X:\\L6046\\Data_Publication\\Pma\\current\\ventura\\pma.vp  

U.S. Energy Information Administration (EIA) Indexed Site

by PAD District, 1983-Present (Cents per Gallon Excluding Taxes) - Continued Geographic Area Year Aviation Gasoline Kerosene-Type Jet Fuel Propane Kerosene Sales to End Users...

278

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2011  

E-Print Network (OSTI)

Fluorescent Lamps and Incandescent Reflector Lamps EPACTBallasts and Fixtures General Service Incandescent Lamps,Intermediate Base Incandescent Lamps and Candelabra Base

Meyers, Stephen

2013-01-01T23:59:59.000Z

279

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 through 2012  

E-Print Network (OSTI)

Fluorescent Lamps and Incandescent Reflector Lamps EPACTBallasts and Fixtures General Service Incandescent Lamps,Intermediate Base Incandescent Lamps and Candelabra Base

Meyers, Stephen

2013-01-01T23:59:59.000Z

280

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2010  

E-Print Network (OSTI)

Fluorescent Lamps and Incandescent Reflector Lamps MediumBallasts and Fixtures General Service Incandescent Lamps,Intermediate Base Incandescent Lamps and Candelabra Base

Meyers, Stephen

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Tomorrow's cities -the lamp-posts watching every move1 by Jane Wakefield for BBC News2  

E-Print Network (OSTI)

that data can be used for both good9 and bad. If that is the bad then consider the good. In Oslo, the city) industry.18 19 It can make cities much more efficient.20 In the US, Philadelphia estimates the city council is looking to upgrade its23 streetlights to more energy-efficient LED lights - likely

South Bohemia, University of

282

Visible Light Digital Camera --Up to 2.3MP resolution with LED lamps provides sharp images  

E-Print Network (OSTI)

· Laser LocatIRTM Pointer -- Pinpoints the hot spot on the IR image with the real physical target (FLIR i case FLIR i40 Additional Features · 0.6MP Visible Light Camera resolution · Picture in Picture (PIP) fixed · 14,400 pixels (120 x 120) FLIR i50 Additional Features · 2.3MP Visible Light Camera resolution

Short, Daniel

283

Utveckling av elektronik och solpanel till portabel solcellsdriven lampa; Development of electronics and solar panel for portable solar cell lamp.  

E-Print Network (OSTI)

?? Syftet med detta projekt har varit att utveckla en solpanel och elektroniken till en portabel solcellsdriven lampa. Huvuddelarna i systemet är en solpanel, en… (more)

Melin, David

2010-01-01T23:59:59.000Z

284

Experimental Security Analyses of Non-Networked Compact Fluorescent Lamps: A Case Study of Home Automation Security  

E-Print Network (OSTI)

}@uw.edu ABSTRACT Background. With a projected rise in the procurement of home automation systems, we experimentally-enabled home automation systems. Aim. This work seeks to investigate the feasibility of causing physical harm--such as through the explosion of CFLs--to home occupants through an exploited home automation system. Method. We

Kohno, Tadayoshi

285

Fading of quinoline dye by light: application to the measurement of the integrated lamp output and solar energy  

Science Journals Connector (OSTI)

The fading rates of plastic plates dyed with a quinoline derivative (quinophthalone) have been measured under exposure to light of 366-, 404.7-, and 435.8-nm wavelengths and to a high...

Okabe, Hideo

1981-01-01T23:59:59.000Z

286

THE CARBON-LAND MODEL INTERCOMPARISON PROJECT (C-LAMP): A PROTOTYPE FOR COUPLED BIOSPHERE-ATMOSPHERE MODEL  

E-Print Network (OSTI)

often referred to as Earth System Models (ESMs). While a number of terrestrial and ocean carbon models

Hoffman, Forrest M.

287

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in India  

E-Print Network (OSTI)

Equipment years years Incandescent Lamps (Residential)W CFL 4hr/day Chinese Data Incandescent Lamps (Commercial)and Industrial End Uses Incandescent Lamps Refrigerators Air

McNeil, Michael A.

2013-01-01T23:59:59.000Z

288

ENERGY EFFICIENT LIGHTING PROGRAM. CHAPTER FROM THE ENERGY AND ENVIRONMENT DIVISION ANNUAL REPORT 1979  

E-Print Network (OSTI)

socket for a standard incandescent lamp. Once the diffuserwhether the lamp is fluorescent or incandescent, Comparedto the incandescent lamp, the circline fluorescent improves

Berman, S.

2013-01-01T23:59:59.000Z

289

2006 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network (OSTI)

10,000 hours) than incandescent lamps (usually estimated atcurrent plus several future incandescent lamp purchases. Themany times longer than incandescent lamps, maintenance costs

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla; Homan, Gregory K.

2006-01-01T23:59:59.000Z

290

Radiative Heat Transfer in Enhanced Hydrogen Outgassing of Glass  

E-Print Network (OSTI)

samples are exposed to an incandescent lamp. Acknowledgmentin a furnace or by an incandescent lamp. It was observedwhen heated by an incandescent lamp than within furnace.

Kitamura, Rei; Pilon, Laurent

2009-01-01T23:59:59.000Z

291

2007 Status Report: Savings Estimates for the ENERGY STAR(R) VoluntaryLabeling Program  

E-Print Network (OSTI)

10,000 hours) than incandescent lamps (usually estimated atcurrent plus several future incandescent lamp purchases. Themany times longer than incandescent lamps, maintenance costs

Sanchez, Marla; Webber, Carrie A.; Brown, Richard E.; Homan, Gregory K.

2007-01-01T23:59:59.000Z

292

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China  

E-Print Network (OSTI)

and Industrial End Uses Incandescent Lamps RefrigeratorsMachines Industrial Motors Incandescent Lamps Standby PowerGas Water  Heaters,  Incandescent  Lamps, 286 Industrial 

McNeil, Michael A.

2012-01-01T23:59:59.000Z

293

2005 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network (OSTI)

10,000 hours) than incandescent lamps (usually estimated atcurrent plus several future incandescent lamp purchases. Themany times longer than incandescent lamps, maintenance costs

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

2006-01-01T23:59:59.000Z

294

White Paper on Energy Efficiency Status of Energy-Using Products in China (2012)  

E-Print Network (OSTI)

Gradually Phasing Out Incandescent Lamps in China has beenhand, a phase- out of incandescent lamps has begun to “Gradually Phasing Out Incandescent Lamps in China in 2011.

Zhou, Nan

2013-01-01T23:59:59.000Z

295

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in the United States  

E-Print Network (OSTI)

Commercial Equipment Incandescent Lamps Refrigerators RoomElectric Water Heaters Incandescent Lamps In 2020 In 2030512 Central AC &  HP , 264 Incandescent  Lamps, 513 Standby 

Bojda, Nicholas

2011-01-01T23:59:59.000Z

296

DOE/EIA-0207/2 Residential Energy Consumption Survey:  

Gasoline and Diesel Fuel Update (EIA)

IF HOUSEHOLD DOES NOT USE AND PAY FOR FUEL OIL OR KEROSENE, SKIP TO Q. 58. 49. How many tanks do you have for fuel oil or kerosene? 1 ONE 2 TWQ 3 THREE OR MORE ASK...

297

India Energy Outlook: End Use Demand in India to 2020  

E-Print Network (OSTI)

rural, k=Kerosene m=rural, k=biogas m =urban, k=LPG m=urban,k=LPG k=wood k=kerosene k=biogas k=electricity k=electricity

de la Rue du Can, Stephane

2009-01-01T23:59:59.000Z

298

Word Pro - Untitled1  

U.S. Energy Information Administration (EIA) Indexed Site

5 Fuel Oil and Kerosene Sales, 1984-2010 Total by Fuel Distillate Fuel Oil by Selected End Use Residual Fuel Oil by Major End Use Kerosene by Major End Use 154 U.S. Energy...

299

Identifying Options for Deep Reductions in Greenhouse Gas Emissions from California Transportation: Meeting an 80% Reduction Goal in 2050  

E-Print Network (OSTI)

jet fuel/kerosene, and marine bunker fuels) were principallyjet fuel/kerosene, and marine bunker fuels) dominated thediesel, jet fuel, and marine bunker fuel to over 100 gCO 2

Yang, Christopher; McCollum, David L; McCarthy, Ryan; Leighty, Wayne

2008-01-01T23:59:59.000Z

300

untitled  

Annual Energy Outlook 2012 (EIA)

Gallon Excluding Taxes) Geographic Area Year Aviation Gasoline Kerosene-Type Jet Fuel Propane Kerosene Sales to End Users Sales for Resale Sales to End Users Sales for Resale...

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Illuminating the Pecking Order in Off-Grid Lighting: A Demonstration of LED Lighting for Saving Energy in the Poultry Sector  

E-Print Network (OSTI)

powered by a solar-wind hybrid system, the kerosene house,a 520-watt solar-wind hybrid system to power fluorescentLighting System Kerosene Solar-Wind Hybrid Fluorescent Solar

Tracy, Jennifer

2012-01-01T23:59:59.000Z

302

Identifying Options for Deep Reductions in Greenhouse Gas Emissions from California Transportation: Meeting an 80% Reduction Goal in 2050  

E-Print Network (OSTI)

aviation fuel, up to 50% of marine fuel, 20% of agriculturaljet fuel/kerosene, and marine bunker fuels) were principallyjet fuel/kerosene, and marine bunker fuels) dominated the

Yang, Christopher; McCollum, David L; McCarthy, Ryan; Leighty, Wayne

2008-01-01T23:59:59.000Z

303

Appendix B Page B-1 2008 Nonresidential Compliance Manual August 2008  

E-Print Network (OSTI)

.............................................................B-18 K-2 Standards for Incandescent Reflector Lamps..................................................

304

Bottom-Up Energy Analysis System - Methodology and Results  

E-Print Network (OSTI)

Documents U.S. Rulemaking Documents TSL 4 PHP IncandescentLamps Incandescent Lamps Fluorescent Lamp Ballasts kWh/yrand T5 fluorescent tubes, incandescent lamps, CFLs, Halogen

McNeil, Michael A.

2013-01-01T23:59:59.000Z

305

Energy Efficiency Standards and Labels in North America: Opportunities for Harmonization  

E-Print Network (OSTI)

The US has a standard for incandescent non-reflector lamps.ve ,S m L mc ,L ve ,S m Incandescent Lamps and Luminaires SFluorescent lamps Incandescent reflector lamps Incandescent

Wiel, Stephen

2008-01-01T23:59:59.000Z

306

Rural Vehicles in China: Appropriate Policy for Appropriate Technology  

E-Print Network (OSTI)

gasoline, kerosene and diesel fuel market. Pet Petrochemicalto produce and market single-cylinder diesel engines that

Sperling, Dan; Lin, Zhenhong; Hamilton, Peter

2005-01-01T23:59:59.000Z

307

ICDERS July 27-31, 2009 Minsk, Belarus Correspondence to: Jean-Marc.Pascaud@bourges.univ-orleans.fr  

E-Print Network (OSTI)

is the heat of combustion of kerosene. Vm is the molar volume depending on the initial conditions. * Transport

Paris-Sud XI, Université de

308

Fuel.vp  

Gasoline and Diesel Fuel Update (EIA)

1: Kerosene Consumption, Price, and Expenditure Estimates, 2012 State Consumption Prices Expenditures Residential Commercial Industrial Total Residential Commercial Industrial...

309

Intense pulsed light sintering of copper nanoink for printed electronics  

E-Print Network (OSTI)

During the arc plasma generation, the ?ash lamp emits anusing an arc plasma phenomenon in the xenon ?ash lamp [7].

Kim, Hak-Sung; Dhage, Sanjay R.; Shim, Dong-Eun; Hahn, H. Thomas

2009-01-01T23:59:59.000Z

310

Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances  

E-Print Network (OSTI)

Report on Potential Impact of Possible Energy Efficiencyenergy saver”) lamps based on a report analyzing potential lamp efficiency

Meyers, Stephen P.

2008-01-01T23:59:59.000Z

311

Catalog of DC Appliances and Power Systems  

E-Print Network (OSTI)

bulb or tube, a compact fluorescent lamp typically includes an integral ballast, as do HID lamps, and an LED

Garbesi, Karina

2012-01-01T23:59:59.000Z

312

Energy Consumption, Efficiency, Conservation, and Greenhouse Gas Mitigation in Japan's Building Sector  

E-Print Network (OSTI)

and a washroom with bulb-type fluorescent lamps, (5) closingusing incandescent bulbs to fluorescent lamps. This switch

2006-01-01T23:59:59.000Z

313

LED Lamp Project Lights the Way to Flicker-Free Replacement Jade Sky Technologies and UC Davis's California Lighting Technology Center demonstrate the  

E-Print Network (OSTI)

, 2014 ­ Jade Sky Technologies ("JST"), a clean-tech start-up manufacturer of LED Technologies and UC Davis's California Lighting Technology Center demonstrate the lighting Specification. JST collaborated with UC Davis's California Lighting Technology Center

California at Davis, University of

314

CALIFORNIA LIGHTING TECHNOLOGY CENTER, UC DAVIS PHONE: (530) 747-3838 FAX: (530) 747-3812 CLTC.UCDAVIS.EDU DOES YOUR LAMP MEET THE  

E-Print Network (OSTI)

CALIFORNIA LIGHTING TECHNOLOGY CENTER, UC DAVIS PHONE: (530) 747-3838 FAX: (530) 747-3812 CLTC years with free replacement 3 years #12;ABOUT THE CALIFORNIA LIGHTING TECHNOLOGY CENTER, UC DAVIS: CLTC was developed by the California Energy Commission in collaboration with the California Public Utilities

California at Davis, University of

315

Tungsten and tungsten alloy powder metallurgy: Powder production and applications excluding lamps. (Latest citations from the US Patent bibliographic file with exemplary claims). Published Search  

SciTech Connect

The bibliography contains citations of selected patents concerning the preparation of metallic and ceramic powders of tungsten and tungsten alloys, including applications of these materials. The hydrogen reduction of tungsten compounds together with alloying element compounds produce forms with characteristics of high density, hardness, wear resistance, high melting points, and abrasiveness. Topics include production of cathodes, heaters, filament wires, electrical contacts, acoustic absorbers, high-density sheets and coatings, hard penetrators, and tungsten carbide and metallized ceramics. (Contains a minimum of 109 citations and includes a subject term index and title list.)

Not Available

1994-04-01T23:59:59.000Z

316

Table Set-up with Materials near Lamp Stand (below) Target Audience: Parents of elementary school students (grades 3-6) and Middle and High School Students  

E-Print Network (OSTI)

spectrum with different light sources; compact fluorescent, LED, incandescent. 5. Discuss light bulb. Observe difference of color spectrum with different light sources; compact fluorescent, LED, incandescent type of bulb at different horizontal level. Electromagnetic Spectrum handouts that includes spectrum

Linhardt, Robert J.

317

Universal Waste Management Procedure: 8.42 Created: 7/30/2014 Version: 1.2 Revised: 7/30/2014  

E-Print Network (OSTI)

fluorescent lamps are classified as Universal Wastes due to their mercury content. Other examples of lamps pressure sodium, and metal halide lamps. It can be expected that fluorescent and HID lamps, including green batteries are managed as universal waste. 2. Lamps are defined by the above regulations as "the bulb or tube

Jia, Songtao

318

Effectiveness and relative cost of chemical treatments for the control of post oak and blackjack oak  

E-Print Network (OSTI)

SyylieS SnrinS cetera at SO OhO ppa in &dL an4 Siving 75 ye@eat control, ~ ~, Oeneral vice of the area of the 1950 ~ atony treatnante phetographeC in JlLLgy 1950@ e ~ ~ S treateS in 4?~ aeaear of 19 ~ Photograph taken cming ~ 1954 i ~ ~ ~ ~ e... 2)~) 5-T I Ester 16 ) UOO pe% 20)000 ppst 8)000 ppm 12 ) 000 pps 16)000 pp)a 20 ) 000 ppa Kerosene 5 7 Kerosene 13 8 Kerosene 3 14 0 0 5 7 0 2 51 5 7 0 3 25 Kerosene 10 12 3 8 0 2 37 Kerosene 18 7 5 3 0 0 69 Kerosene 14 13 2 4 0 0 49...

Suffel, Paul H

2012-06-07T23:59:59.000Z

319

851 S.W. Sixth Avenue, Suite 1100 Steve Crow 503-222-5161 Portland, Oregon 97204-1348 Executive Director 800-452-5161  

E-Print Network (OSTI)

th Plan estimated that the conversion of standard incandescent bulbs used in the residential sector standard does not cover all incandescent lamps (e.g., lamps over 100 watts, 3- way lamps are exempt

320

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

reports power savings from incandescent/CFL lamp replacementreplacement of a 65 W incandescent lamp with a 16 W compactthe equivalent of 109 W incandescent lamp, the average of

Homan, GregoryK

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

851 S.W. Sixth Avenue, Suite 1100 Steve Crow 503-222-5161 Portland, Oregon 97204-1348 Executive Director 800-452-5161  

E-Print Network (OSTI)

Plan estimated that the conversion of standard incandescent bulbs used in the residential sector not cover all incandescent lamps (e.g., lamps over 100 watts, 3-way lamps are exempt), it does cover 70

322

ENERGY EFFICIENT LIGHTING PRODUCTS TEST METHOD SELECTION LIST  

E-Print Network (OSTI)

:1991 Incandescent Lamps - Electrical Measurements ______ 22/E13* IES LM-45:2000 Incandescent Lamps - Electrical Measurements ______ 22/E13a* IES LM-45:2009 Incandescent Lamps - Electrical Measurements ______ 22/E14 IES LM

323

The impact of modern headlamps on the design of sag vertical curves  

E-Print Network (OSTI)

to the lens. The housing serves as a reflector and lens, and is made of plastic. These lamps may be comprised of different light emitting diode?s (LEDs), high intensity discharge (HID) lamps, and halogen lamps. Halogen headlamps are further comprised... on. HID lamps produce more light compared to halogen lamps (22). Also, HID lamps have a sharper horizontal cut-off beam pattern further reducing the portion of lighted highway on sag curves (25). Light emitting diode is another headlamp...

Gogula, Madhuri

2006-08-16T23:59:59.000Z

324

State of Maine residential heating oil survey 2001-02 season summary [SHOPP  

SciTech Connect

This, as the title implies, is a summary report of the price trends for heating oil, propane and kerosene heating fuels for the heating season.

Elder, Betsy

2002-05-22T23:59:59.000Z

325

China Energy Databook - Rev. 4  

E-Print Network (OSTI)

I.I Electricity f District Heating U Kerosene Town Naturalper hour) for district heating systems, in cogenerationThe electricity and district heating categories are composed

Sinton Editor, J.E.

2010-01-01T23:59:59.000Z

326

Key China Energy Statistics 2012  

E-Print Network (OSTI)

Kerosene Petroleum Other Products Refinery Gas Diesel OilGasoline Liquid Petroleum Gas Refinery Production by ProductPetroleum Other Products Refinery Gas Diesel Oil Gasoline

Levine, Mark

2013-01-01T23:59:59.000Z

327

Residential Buildings Historical Publications reports, data and...  

Annual Energy Outlook 2012 (EIA)

1 Average Fuel OilKerosene Residential Buildings Consumption Expenditures per Total per Square per per per Total Total Floorspace Building Foot per Household per Square per...

328

Residential Buildings Historical Publications reports, data and...  

Gasoline and Diesel Fuel Update (EIA)

90 Average Fuel OilKerosene Residential Buildings Consumption Expenditures per Total per Square per per per Total Total Floorspace Building Foot per Household per Square per...

329

Residential Buildings Historical Publications reports, data and...  

Annual Energy Outlook 2012 (EIA)

7 Average Fuel OilKerosene Residential Buildings Consumption Expenditures per Total per Square per per per Total Total Floorspace Building Foot per Household per Square per...

330

Residential Buildings Historical Publications reports, data and...  

Gasoline and Diesel Fuel Update (EIA)

2 Average Fuel OilKerosene Residential Buildings Consumption Expenditures per Total per Square per per per Total Total Floorspace Building Foot per Household per Square per...

331

Residential Buildings Historical Publications reports, data and...  

Gasoline and Diesel Fuel Update (EIA)

0 Average Fuel OilKerosene Residential Buildings Consumption Expenditures per Total per Square per per per Total Total Floorspace Building Foot per Household per Square per...

332

Residential Buildings Historical Publications reports, data and...  

Gasoline and Diesel Fuel Update (EIA)

4 Average Fuel OilKerosene Residential Buildings Consumption Expenditures per Total per Square per per per Total Total Floorspace Building Foot per Household per Square per...

333

Biofuel Characteristics in Micro Turbojet Engine Application.  

E-Print Network (OSTI)

?? The engine performance and fuel consumption of a micro gas turbojet engine running mixtures of B1OO biodiesel fuel and kerosene are reported in this… (more)

Tan, Ing Huang

2012-01-01T23:59:59.000Z

334

Alternative Fuels Data Center  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Biofuels Quality Specifications The Tennessee Department of Agriculture may inspect and test biofuels under the Kerosene and Motor Fuels Quality Inspection Act of 1989. (Reference...

335

Energy Information Administration/Petroleum Marketing Annual  

Gasoline and Diesel Fuel Update (EIA)

19 Table A2. RefinerReseller Prices of Aviation Fuels, Propane, and Kerosene, by PAD District, 1983-Present (Cents per Gallon Excluding Taxes) Geographic Area Year Aviation...

336

Table A2. Refiner/Reseller Prices of Aviation Fuels, Propane...  

Gasoline and Diesel Fuel Update (EIA)

Marketing Annual 1995 467 Table A2. RefinerReseller Prices of Aviation Fuels, Propane, and Kerosene, by PAD District, 1983-Present (Cents per Gallon Excluding Taxes) -...

337

This Week In Petroleum Printer-Friendly Version  

Gasoline and Diesel Fuel Update (EIA)

motor gasoline, distillate fuel oil, kerosene-type jet fuel, residual fuel oil, and propane, and there is no weekly inventory data for "other oils." Therefore, both weekly...

338

Table A2. Refiner/Reseller Prices of Aviation Fuels, Propane...  

Gasoline and Diesel Fuel Update (EIA)

Marketing Annual 1999 421 Table A2. RefinerReseller Prices of Aviation Fuels, Propane, and Kerosene, by PAD District, 1983-Present (Cents per Gallon Excluding Taxes) -...

339

Word Pro - Untitled1  

Annual Energy Outlook 2012 (EIA)

Information Administration Annual Energy Review 2011 1 Electricity only; excludes electrical system energy losses. 2 Distillate fuel oil, residual fuel oil, and kerosene....

340

oil1990.xls  

Annual Energy Outlook 2012 (EIA)

(dollars) (dollars) (dollars) (dollars) Table 1. Consumption and Expenditures in U.S. Households that Use Fuel OilKerosene, 1990 Residential Buildings Average Fuel Oil...

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Pre-clinical Measures of Eye Damage (Lens Opacity), Case-control Study of Tuberculosis, and Indicators of Indoor Air Pollution from Biomass Smoke  

E-Print Network (OSTI)

air pollution from biomass combustion and acute respiratoryparticulate matter from combustion of biomass fuels in ruralcountries where combustion of biomass and kerosene is common

Pokhrel, Amod Kumar

2010-01-01T23:59:59.000Z

342

Distillate Fuel Oil Sales for Residential Use  

Annual Energy Outlook 2012 (EIA)

End Use Product: Residential - Distillate Fuel Oil Residential - No. 1 Residential - No. 2 Residential - Kerosene Commercial - Distillate Fuel Oil Commercial - No. 1 Distillate...

343

LIFE CYCLE ASSESSMENTS (LCAs) OF PYROLYSIS-BASED GASOLINE AND DIESEL FROM DIFFERENT REGIONAL FEEDSTOCKS: CORN STOVER, SWITCHGRASS, SUGAR CANE BAGASSE, WASTE WOOD, GUINEA GRASS, ALGAE, AND ALBIZIA.  

E-Print Network (OSTI)

?? Renewable hydrocarbon biofuels are being investigated as possible alternatives to conventional liquid transportation fossil fuels like gasoline, kerosene (aviation fuel), and diesel. A diverse… (more)

Mihalek, Matthew J.

2014-01-01T23:59:59.000Z

344

PHASE I FINAL REPORT SUBCONTRACT NO. 2019702 "ENERGY EFFICIENT FLUORESCENT BALLASTS"  

E-Print Network (OSTI)

RELATIVE EFFICIENCY (FOOT CANDLES/POWER IN) LAMP TEMPERATUREEFFICIENCY (FOOT CANDLES/POWER IN) LAMP TEMPERATURE *INPUT CURRENT POWER INPUT POWER FACTOR LIGHT IN FOOT CANDLES

Authors, Various

2011-01-01T23:59:59.000Z

345

Federal Register Vol. 76 No. 44, 12422-12505 - Energy Conservation...  

Energy Savers (EERE)

for High-Intensity Discharge Lamps; Supplemental Notice of Proposed Rulemaking 2014-05-16 Issuance: Test Procedures for Integrated Light-Emitting Diode Lamps; Supplemental...

346

Sandia National Laboratories: Brief History of Artificial Lighting...  

NLE Websites -- All DOE Office Websites (Extended Search)

lifetime; as demonstrated by the evolution from lamps that utilize the electric arc then to carbon-filament and finally to metal-filament lamps. Incandescence culmination...

347

2014-10-14 Issuance: Test Procedures Correction for Fluorescent...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

10-14 Issuance: Test Procedures Correction for Fluorescent Lamp Ballasts; Notice of Proposed Rulemaking 2014-10-14 Issuance: Test Procedures Correction for Fluorescent Lamp...

348

Slide 0  

U.S. Energy Information Administration (EIA) Indexed Site

(August 6, 2001 version) for efficacy, lumen maintenance, lamp life, rapid cycle stress test, CRI, etc. The standard is effective for lamps manufactured on or after January 1,...

349

2014-05-05 Issuance: Test Procedures for High-Intensity Discharge...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Test Procedures for High-Intensity Discharge Lamps; Supplemental Notice of Proposed Rulemaking 2014-05-05 Issuance: Test Procedures for High-Intensity Discharge Lamps; Supplemental...

350

DSM Electricity Savings Potential in the Buildings Sector in APP Countries  

E-Print Network (OSTI)

150 million compact fluorescent light bulbs in 2010. (ChinaCleaners Incandescent Bulbs Fluorescent Lamps Ballasts forincandescent bulbs with compact fluorescent lamps. Consumers

McNeil, MIchael

2011-01-01T23:59:59.000Z

351

Zinc Oxide and Nitride Nanowire Based Light Emitting Diodes  

E-Print Network (OSTI)

of incandescent light bulb, fluorescent lamp, and blue lightof incandescent light bulb, fluorescent lamp, and blue lightincandescent bulb and is on the same order as fluorescent

Lai, Elaine Michelle

2009-01-01T23:59:59.000Z

352

National High Magnetic Field Laboratory: Museum of Electricity...  

NLE Websites -- All DOE Office Websites (Extended Search)

example, are often useful in widefield fluorescence microscopy. Related Electricity & Magnetism Pages Interactive Java Tutorials: Arc Lamp Museum: Fluorescent Lamp Pioneers: Sir...

353

National High Magnetic Field Laboratory: Museum of Electricity...  

NLE Websites -- All DOE Office Websites (Extended Search)

and businesses as an energy-saving alternative to incandescent. Related Electricity & Magnetism Pages Interactive Java Tutorials: Arc Lamp Museum: Arc Lamp Pioneers: Nikola Tesla...

354

Global Potential of Energy Efficiency Standards and Labeling Programs  

E-Print Network (OSTI)

lighting (replacement of incandescent lamps with CFLs) withof each type of lamp: incandescent; fluorescent tubes; andless consumptive than incandescent bulbs. Second, it impacts

McNeil, Michael A

2008-01-01T23:59:59.000Z

355

Stalled on the Road to the Market: Analysis of Field Experience with a Project to Promote Lighting Efficiency in India  

E-Print Network (OSTI)

several rea- sons: (1) incandescent lamps, the products thatin replacing an incandescent with a CFL is unmatched in anysame quantity of light as an incandescent lamp. The BELLE

Gadgil, A.J.

2008-01-01T23:59:59.000Z

356

Residential Electricity Demand in China -- Can Efficiency Reverse the Growth?  

E-Print Network (OSTI)

2000: Lighting Type Incandescent Fluorescent CFL Percentagescenario, we assume that incandescent bulbs are graduallyW 60W 15W Fluorescent Lamps Incandescent Lamps CFL We then

Letschert, Virginie

2010-01-01T23:59:59.000Z

357

Synthesis and luminescence properties of rare earth activated phosphors for near UV-emitting LEDs for efficacious generation of white light  

E-Print Network (OSTI)

lighting using incandescent lights and fluorescent lamps, asenergy used for the incandescent lamp is wasted as infraredsource to replace incandescent and fluorescent lighting [2].

Han, Jinkyu

2013-01-01T23:59:59.000Z

358

Economic Analysis of Ilumex, A Project to Promote Energy-Efficient Residential Lighting in Mexico  

E-Print Network (OSTI)

Results for Replaceable Incandescent Lamps GUADALAJARA:new pesoslkWh respectively. Incandescent bulb purchase iscompared to conventional incandescent lamps, but its much

Sathaye, Jayant A.

2008-01-01T23:59:59.000Z

359

2014-04-11 Issuance: Energy Conservation Standards for General...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps; Notice of Proposed Rulemaking 2014-04-11 Issuance: Energy Conservation...

360

Calendar Year 2007 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network (OSTI)

weighted average across incandescent, CFL, and non-ENERGYreports power savings from incandescent/CFL lamp replacementreplacement of a 65 W incandescent lamp with a 16 W compact

Sanchez, Marla Christine

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Acting Globally: Potential Carbon Emissions Mitigation Impacts from an International Standards and Labelling Program  

E-Print Network (OSTI)

both fluorescent and incandescent), standby power (forFluorescent Tubes Incandescent Lamps All % of CFL variableRefrigerator Savings Incandescent Lamp Savings Fluorescent

Letschert, Virginie E.

2010-01-01T23:59:59.000Z

362

Energy Management A Program of Energy Conservation for the Community College Facility  

E-Print Network (OSTI)

whenever possible) Lamps Type (incandescent, fluorescent,are as follows: Lamp Type Incandescent FI uorescent Mercurylumens/watt lumens/watt Incandescent Mercury Metal Additive

Authors, Various

2011-01-01T23:59:59.000Z

363

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps High-Intensity Discharge Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for high-intensity discharge (HID) lamps. HID lamps are electric discharge lamps and include high-pressure sodium, mercury vapor, and metal halide lamps. HID lamps require an HID ballast to start and regulate electric current flow through the lamp. HID lamps are used in street and roadway lighting, area lighting such as for parking lots and plazas, industrial and commercial building interior lighting, security lighting for commercial, industrial, and residential spaces, and landscape lighting. The Standards and Test Procedures for this product are related to Rulemaking for High Intensity Discharge Lamps Energy Conservation Standard and Rulemaking for High Intensity Discharge Lamps Test Procedures.

364

Cost effective lighting  

SciTech Connect

Long-life replacement lamps for the incandescent lamp have been evaluated with regard to their cost effectiveness. The replacements include the use of energy buttons that extend lamp life as well as an adaptive fluorescent circline lamp that will fit into existing incandescent lamp sockets. The initial, operating, and replacement costs for one million lumen-hours are determined for each lamp system. We find the most important lighting cost component is the operating cost. Using lamps that are less efficient or devices that cause lamps to operate less efficiently are not cost-effective. The adaptive fluorescent circline lamp, even at an initial cost of $15.00, is the most cost effective source of illumination compared to the incandescent lamp and lamp systems examined. 3 refs., 6 tabs.

Morse, O.; Verderber, R.

1987-07-01T23:59:59.000Z

365

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES  

E-Print Network (OSTI)

;Page #3 b. The tank is for storage of fuel oil, kerosene, gasoline or diesel fuel used solely for on-site heating, irrigation, or intermittent stationary power production c. The tank is located on residential of the tank is less than 1,100 gallons b. The tank is for storage of fuel oil, kerosene, gasoline or diesel

366

Suffolk County Department of Health Services  

E-Print Network (OSTI)

, the product stored is #2 fuel oil, #4 fuel oil, #6 fuel oil, kerosene, or diesel, the purpose of which is solely for on-site heating or intermittent stationary power production and whose total on-site storage storing #2 fuel oil, #4 fuel oil, #6 fuel oil, kerosene, or diesel, the purpose of which is solely for on

367

Lung Cancer in Never Smokers: Clinical Epidemiology and Environmental Risk Factors  

Science Journals Connector (OSTI)

...modern cooking fuels (gas, electricity, or kerosene...modern cooking fuel (gas, electricity, or kerosene...which involve heating oil to high temperatures...for different types of oils used for cooking and exposure...case-control study from Missouri (OR 1.1; 95% CI 0...

Jonathan M. Samet; Erika Avila-Tang; Paolo Boffetta; Lindsay M. Hannan; Susan Olivo-Marston; Michael J. Thun; and Charles M. Rudin

2009-09-15T23:59:59.000Z

368

FACILITIES MAINTENANCE MAIN WAREHOUSE  

E-Print Network (OSTI)

Just-In-Time delivery (HVAC filters, automotive tires, lamps) (In Work) - Unrestricted warehouse access

Hemmers, Oliver

369

EA-1881: Final Environmental Assessment  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011)

370

Power Quality Improvements in Lighting Systems Mr. Ashish Shrivastava  

E-Print Network (OSTI)

from early incandescent lamps to present generation light emitting diodes (LEDs). Incandescent light

Kumar, M. Jagadesh

371

Assessing the Performance of 5mm White LED Light Sources for Developing-Country Applications  

E-Print Network (OSTI)

performance variations. Incandescent and fluorescent lightbetter than the common incandescent lamp. Off-grid lighting

Mills, Evan

2007-01-01T23:59:59.000Z

372

 

U.S. Energy Information Administration (EIA) Indexed Site

821, Annual Fuel Oil and Kerosene Sales Report Page 1 821, Annual Fuel Oil and Kerosene Sales Report Page 1 U.S. DEPARTMENT OF ENERGY U.S. ENERGY INFORMATION ADMINISTRATION Washington, D. C. 20585 OMB No. 1905-0174 Expiration Date: 12/31/2015 Version No.: 2013.01 FORM EIA-821 ANNUAL FUEL OIL AND KEROSENE SALES REPORT INSTRUCTIONS 1. QUESTIONS? If you have any questions about Form EIA-821 after reading the instructions, please call our toll-free number 1-800-638- 8812. 2. PURPOSE The U.S. Energy Information Administration (EIA) Form EIA- 821, "Annual Fuel Oil and Kerosene Sales Report," is used to collect annual data on the sales of distillate and residual fuel oils, and kerosene to various categories of energy users at the State level. The data are used by EIA and the Department of

373

Experience of the Städtische Werke AG (the Municipal Utility of the City of Kassel, Germany) with Rebate Programmes for Energy-Efficient Household Appliances and Lamps Over the Last 4 Years  

Science Journals Connector (OSTI)

Please permit me to commence with a brief presentation of our company and the city of Kassel (201,500 habitants). Geographically speaking, Kassel is in the centre of Germany and thus right in the middle of Eur...

Günther Frey

1999-01-01T23:59:59.000Z

374

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Certain Lamps Exempted from General Service Incandescent Lamp Standards Certain Lamps Exempted from General Service Incandescent Lamp Standards Sign up for e-mail updates on regulations for this and other products The information on this page pertains to the Department of Energy's (DOE) analysis of and unit sales forecast for five lamp types, which was mandated by the Energy Independence and Security Act of 2007 (EISA 2007). Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to evaluate and publish within 1 year a benchmark unit sales estimate for five types of incandescent lamps (rough service lamps, vibration service lamps, 3-way incandescent lamps, 2,601-3,300 lumen general service incandescent lamps, and shatter-resistant lamps). These lamp types were not made subject to the regulatory standards for general service incandescent lamps established by EISA 2007. Among the requirements of subtitle B of title III of EISA 2007 were provisions directing DOE to collect, analyze, and monitor unit sales of these five lamp types.

375

Workbook Contents  

U.S. Energy Information Administration (EIA) Indexed Site

Total Distillate and Kerosene " Total Distillate and Kerosene " ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","Prime Supplier Sales Volumes of Total Distillate and Kerosene ",60,"Monthly","9/2013","1/15/1983" ,"Release Date:","11/26/2013" ,"Next Release Date:","12/23/2013" ,"Excel File Name:","pet_cons_prim_a_epded_k_p00_mgalpd_m.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/pet/pet_cons_prim_a_epded_k_p00_mgalpd_m.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.gov"

376

Finished Motor Gasoline Net Production  

Gasoline and Diesel Fuel Update (EIA)

Data Series: Finished Motor Gasoline Finished Motor Gasoline (less Adj.) Reformulated Gasoline Reformulated Gasoline Blenede w/ Fuel Ethanol Reformulated Other Gasoline Conventional Gasoline Conventional Gasoline Blended w/ Fuel Ethanol Conventional Gasoline Blended w/ Fuel Ethanol, Ed55 & Ed55 Other Conventional Gasoline Finished Motor Gasoline Adjustment Kerosene-Type Jet Fuel Kerosene-Type Jet, Commercial Kerosene-Type Jet, Military Distillate Fuel Oil Distillate Fuel Oil, 15 ppm Sulfur and Under Distillate Fuel Oil > 15 ppm to 500 ppm Sulfur Distillate Fuel Oil > 500 ppm Sulfur Residual Fuel Oil Propane/Propylene Period: Weekly 4-Week Average

377

EA-1664: Final Environmental Assessment | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

64: Final Environmental Assessment 64: Final Environmental Assessment EA-1664: Final Environmental Assessment 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps,

378

Group decision making based autonomous control system for street lighting  

Science Journals Connector (OSTI)

Most traditional street lighting systems do not have the function of autonomous control. Inspired by social animals and insects, an autonomous control system for street lighting is presented in this paper. All the lamp nodes compose a wireless sensor network (WSN) based lamp group in which there are a lamp leader, a succeeding leader, and some lamp members. All the lamp members communicate with the lamp leader by forming a tree topology. The lamp member collects ambient illumination using a light sensor periodically. When finding the illumination is under the preset threshold, the lamp member will send a turning-on vote to the lamp leader. The lamp leader counts the number of votes received from the members. When the number of the votes is larger than the preset threshold, the lamp leader will send a turning-on command to all the lamp members. Just like the succession behavior in social animals, the succeeding leader in the proposed system can automatically take the place of the current lamp leader when it is disabled. A failure message can be sent to the remote street lighting maintenance center by a GPRS network. Leader switching and group decision making tests have been carried out for validating these proposed methods. The experimental results show that the proposed system can automatically response to ambient light changes. The method of group decision making improves the anti-interference capability and the intelligence level of the lighting control system.

Jun Zhang; Guifang Qiao; Guangming Song; Hongtao Sun; Jian Ge

2013-01-01T23:59:59.000Z

379

This Week In Petroleum Printer-Friendly Version  

Annual Energy Outlook 2012 (EIA)

distillates, kerosene-jet fuel, residual fuel oil, and propane in the Weekly Petroleum Status Report (WPSR), could be tempted to read too much into the week-to-week fluctuations...

380

Images in Emergency Medicine: Irritant Contact Dermatitis from Jet Fuel  

E-Print Network (OSTI)

and penetration of JP-8 jet fuel and its components. Toxicoland other kerosene-based fuels have been shown to cause skinContact Dermatitis from Jet Fuel Christopher C. Trigger, MD

Trigger, Christopher C; Eilbert, Wesley

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Table 50. Prime Supplier Sales Volumes of Distillate Fuel Oils...  

U.S. Energy Information Administration (EIA) Indexed Site

No. 2 Distillate No. 4 Fuel a Total Distillate and Kerosene No. 2 Fuel Oil No. 2 Diesel Fuel No. 2 Distillate Low-Sulfur High-Sulfur Total United States January...

382

OMB No. 038-R0459 EIA 457B  

U.S. Energy Information Administration (EIA) Indexed Site

PARTS q and r), ASK Q. 163 ff. OTHERWISE SKIP TO INSTRUCTION FOR Q. 176. 163. How many tanks do you have for fuel oil or kerosene? ONE TWO THREE OR MORE 1232 164. What is the...

383

TEX-A-SYST: Reducing the Risk of Ground Water Contamination by Improving Petroleum Product Storage  

E-Print Network (OSTI)

This publication focuses on safe storage of gasoline, diesel, kerosene and liquid heating fuels. It includes information about storage tank location, tank design and installation, tank monitoring, and tank closure....

Harris, Bill L.; Hoffman, D.; Mazac Jr., F. J.; Kantor, A. S.

1997-08-29T23:59:59.000Z

384

Inference from a Deterministic Population Dynamics Model for Bowhead Whales  

E-Print Network (OSTI)

. This research was supported by the North Slope Borough, Alaska, the State of Alaska (through the Alaska, the replacement of whale oil by kerosene, and the decreased use of baleen corset stays discouraged commercial

Givens, Geof H.

385

Heats of Combustion of Fatty Acids and Fatty Acid Esters  

Science Journals Connector (OSTI)

...The military uses JP-8, a kerosene type hydrocarbon, to fuel most of its vehicles and ... , no traditional biodiesel meets the requirements for heat of combustion, freezing point, viscosity and oxidative stabi...

Felicia Levine; Ronald V. Kayea III…

2014-02-01T23:59:59.000Z

386

Dynamic study of coupled heavy hydrocarbon pyrolysis and combustion. N. Gascoina*  

E-Print Network (OSTI)

1/28 Dynamic study of coupled heavy hydrocarbon pyrolysis and combustion. N. Gascoina* , P of the heat transfer dynamics. Finally, the combustion mechanism is applied and validated experimentally for kerosene pyrolysis application. Keywords Regenerative cooling; Hydrocarbon pyrolysis; Supersonic Combustion

Boyer, Edmond

387

Mutagenicity of Soot and Associated Polycyclic Aromatic Hydrocarbons to Salmonella typhimurium  

Science Journals Connector (OSTI)

...polycyclic aromatic hydrocarbons were quantitatively...polycyclic aromatic hydrocarbon constituent in a kerosene...polycyclic aromatic hydrocarbon fraction in terms of...formed by the incomplete combustion of organic material...and sediments (1), heat and power generation...

Debra A. Kaden; Ronald A. Hites; and William G. Thilly

1979-10-01T23:59:59.000Z

388

Pre-clinical Measures of Eye Damage (Lens Opacity), Case-control Study of Tuberculosis, and Indicators of Indoor Air Pollution from Biomass Smoke  

E-Print Network (OSTI)

Indoor air pollution from biomass fuels and respiratoryTuberculosis and Indoor Biomass and Kerosene Use in Nepal: AR.D. Retherford, and K.R. Smith, Biomass cooking fuels and

Pokhrel, Amod Kumar

2010-01-01T23:59:59.000Z

389

,"Housing Units1","Average Square Footage Per Housing Unit",...  

U.S. Energy Information Administration (EIA) Indexed Site

"Fuel Oil",0.2,2365,2071,308,966,846,126 "Kerosene",0.2,1913,1729,751,640,579,251 "Solar",0.5,2530,1924,1084,963,732,413 "Main Space Heating Fuel" "Natural...

390

The Transuranium Elements  

E-Print Network (OSTI)

TBP diluted with a kerosene type solvent is used. The uranium slugs are dissolved in nitric acid,nitric acid solution containing a reducing is agent. LJranium(~1) left in the TBP

Hyde, Earl K.; Seaborg, Glenn T.

1956-01-01T23:59:59.000Z

391

Thermodynamic Investigations of Aqueous Ternary Complexes for Am/Cm Separation  

E-Print Network (OSTI)

not extractable by TBP at high nitric acid concentrations.that TBP is also more stable against attack by nitric acid.TBP in kerosene to extract Pu(IV) and U(VI) from nitric acid

Leggett, Christina Joy

2012-01-01T23:59:59.000Z

392

Solar-powered drip irrigation enhances food security in the Sudano–Sahel  

Science Journals Connector (OSTI)

...vegetable consumption increased...a liquid-fuel (gasoline...kerosene) engine-driven pump...of total consumption expenditure...household produce consumption, kg/month...and liquid-fuel engine-driven...

Jennifer Burney; Lennart Woltering; Marshall Burke; Rosamond Naylor; Dov Pasternak

2010-01-01T23:59:59.000Z

393

Solar-powered drip irrigation enhances food security in the Sudano–Sahel  

Science Journals Connector (OSTI)

...as expected, consumption of vegetables for...entirely by increased consumption during the dry season...above, vegetable consumption increased...which a liquid-fuel (gasoline, diesel, kerosene) engine-driven pump has...

Jennifer Burney; Lennart Woltering; Marshall Burke; Rosamond Naylor; Dov Pasternak

2010-01-01T23:59:59.000Z

394

Your Home Fire Safety Checklist  

NLE Websites -- All DOE Office Websites (Extended Search)

operates ventilated (e.g. door open or the window ajar). This will prevent an indoor air pollution problem and minimize health prob- lems. Kerosene heaters are not usually...

395

Table A2. Refiner/Reseller Prices of Aviation Fuels, Propane...  

Gasoline and Diesel Fuel Update (EIA)

- W 73.5 See footnotes at end of table. A2. RefinerReseller Prices of Aviation Fuels, Propane, and Kerosene, by PAD District, 1983-Present Energy Information Administration ...

396

Coaggregation by the Freshwater Bacterium Sphingomonas natatoria Alters Dual-Species Biofilm Formation  

Science Journals Connector (OSTI)

...180 min were the occasional larger glass-attached clusters observed...continued to develop to form large stacks of biofilm cells that...diversity in kerosene-based drilling fluid from the deep ice borehole at Vostok, East Antarctica...

K. R. Min; A. H. Rickard

2009-04-17T23:59:59.000Z

397

Opportunities to reduce greenhouse gas emissions from households in Nigeria  

Science Journals Connector (OSTI)

Efforts to mitigate climate threats should not exclude the household as the household is a major driver of greenhouse gas (GHG) emissions through its consumption...2) emissions from kerosene combustion for lighting

O. Adeoti; S. O. Osho

2012-02-01T23:59:59.000Z

398

Bibliography and Index to the Literature on Gas Chromatography—1966 November 1, 1965 to November 1, 1966  

Science Journals Connector (OSTI)

......CHROIVIATOGRAPHY. I. SOME GENERAL RELATIONSHIPS BETWEEN THE QUANTI...IN PLU- TONIUM PURIFICATION CYCLES WITH TRILAURYLAMINE, Perez...1306 KEROSENE, JET FUELS AND DIESEL FUELS, Peters, U. James...PERIPHERAL BLOOD OF THE MENSTRUAL CYCLE, Runnebaum, Benno, van der......

Seaton T. Preston; Jr.; Mignon Gill

1966-12-01T23:59:59.000Z

399

Transportation Biofuels in the US A Preliminary Innovation Systems Analysis  

E-Print Network (OSTI)

Production by Source (Base_Bio) Quads Fuel Quads_Corn Quads_fuel Residual Kerosene Electricity CNG F-T Diesel Bio-Dieselfuel). 28 Figure 7: Energy use and greenhouse gases (base_bio) .

Eggert, Anthony

2007-01-01T23:59:59.000Z

400

Transportation Biofuels in the USA Preliminary Innovation Systems Analysis  

E-Print Network (OSTI)

Production by Source (Base_Bio) Quads Fuel Quads_Corn Quads_fuel Residual Kerosene Electricity CNG F-T Diesel Bio-Dieselfuel). 28 Figure 7: Energy use and greenhouse gases (base_bio) .

Eggert, Anthony

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Solvent extraction of uranyl (II) ion with N,N,N,N-tetrabutylsucinylamide from nitric acid solution  

Science Journals Connector (OSTI)

N,N,N,N-tetrabutylsuccinylamide (TBSA) in a diluent composed of 50% trimethylbenzene (TMB) and 50% kerosene (OK) can extract uranyl (II) ion from nitric acid solution. The results of extraction study suggested...

You-Shao Wang; Chao-Hong Shen; Jian-Kang Zhu…

1996-01-20T23:59:59.000Z

402

European Bulletin of Himalayan Research (EBHR) Volume 27, Autumn 2004  

E-Print Network (OSTI)

. Over the last decade the people of upper Mustang, including Lo Monthang, have borne witness to and helped to create micro-hydro electricity projects, schools, and eco-tourism ventures, to choreograph cultural shows, and build kerosene depots...

South Asia Institute, Heidelberg University, Germany; (CNRS) Centre National de la Recherche Scientifique, France; (SOAS) School of Oriental and African Studies, UK

2004-01-01T23:59:59.000Z

403

Isolation of Penicillium corylophium Dierckx from acid mine water and its optimal growth on hydrocarbons at acid pH  

Science Journals Connector (OSTI)

Penicillium corylophilum Dierckx was isolated from sludge collected at the interface of an aqueous, copper-bearing leachate and an organic, kerosene based, ion exchange solvent. The organism assi...

N. A. Sinclair; C. M. Herring

1975-01-01T23:59:59.000Z

404

Towards Comprehensive Hydrocarbons Analysis of Middle Distillates by LC-GCxGC  

Science Journals Connector (OSTI)

......separation in GC is limited to gasoline (3); that is, products having...especially for the characterization of gasoline (9), kerosene (10), and diesel...of crude oils (referred to as straight run [SR] diesel), from cracking......

Frédérick Adam; Fabrice Bertoncini; Didier Thiébaut; Sébastien Esnault; Didier Espinat; M.C. Hennion

405

--No Title--  

Gasoline and Diesel Fuel Update (EIA)

(bottled gas), or 4. Fuel oil? 5. Kerosene (IF VOLUNTEERED) 6. Wood (IF VOLUNTEERED) 7. Solar (IF VOLUNTEERED) 8. District steam or hot water (IF VOLUNTEERED) 9. Some other fuel...

406

Federal Energy Management Program: Energy Cost Calculator for Compact  

NLE Websites -- All DOE Office Websites (Extended Search)

Compact Fluorescent Lamps to someone by E-mail Compact Fluorescent Lamps to someone by E-mail Share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Facebook Tweet about Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Twitter Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Google Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Delicious Rank Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Digg Find More places to share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories

407

MICROCAVITYMICROCAVITY PLASMA SCIENCE AND RECENTPLASMA SCIENCE AND RECENT APPLICATIONS: BOUNDAPPLICATIONS: BOUND--FREE COUPLING, TRANSISTORFREE COUPLING, TRANSISTOR  

E-Print Network (OSTI)

Plasma Surface Treatment High Intensity Plasma Arc Lamp Spark Gap Plasma Display (150 inch Panasonic Electrode Glass6 mm 250 m LED Backlight Microcavity Lamp #12;OPERATION OF MICROCAVITY PLASMA DEVICESMICROCAVITYMICROCAVITY PLASMA SCIENCE AND RECENTPLASMA SCIENCE AND RECENT APPLICATIONS

Shyy, Wei

408

DOE Publishes New CALiPER Report on Subjective Evaluation of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CALiPER Report on Subjective Evaluation of LED PAR38 Lamps DOE Publishes New CALiPER Report on Subjective Evaluation of LED PAR38 Lamps November 7, 2013 - 12:00am Addthis DOE has...

409

DOE Publishes CALiPER Report on Cost-Effectiveness of Linear...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Report on Cost-Effectiveness of Linear (T8) LED Lamps DOE Publishes CALiPER Report on Cost-Effectiveness of Linear (T8) LED Lamps May 30, 2014 - 4:58pm Addthis The U.S. Department...

410

ADVANCED COATINGS LAB EQUIPMENT & TESTING  

E-Print Network (OSTI)

Mixers � Paint Shakers � Sieve Shaker � Engraver � Abrasive Blast Systems �Application � Robotic Paint Air Breathing System � Virtual Paint Training Units � UV Cure Lamp � IR Cure Lamp �Surface Preparation

411

Metal and metal-free photocatalysts: mechanistic approach and application as  

E-Print Network (OSTI)

.g., household fluorescence or LED bulbs, halogen lamps, sunlight, Xe lamp), e.g., enantioselective alkylation.lalevee@uha.fr * Corresponding author Keywords: LEDs; photoinitiators; photopolymerization; photoredox catalysis Beilstein J. Org

Boyer, Edmond

412

851 S.W. Sixth Avenue, Suite 1100 Steve Crow 503-222-5161 Portland, Oregon 97204-1348 Executive Director 800-452-5161  

E-Print Network (OSTI)

Commercial Central AC and Heat Pumps Refrigerators and Freezers Room Air Conditioners Fluorescent Lamp efficiency standards program and described the historical impact on regional electricity use, Commercial Refrigeration Equipment, Commercial Vending Machines General Service Fluorescent Lamps

413

Secondary Organic Aerosol Formation From Aromatic Hydrocarbon  

E-Print Network (OSTI)

Edney E.O. Izumi K. Sato K. 244 cm fluorescent bulbs 244cm fluorescent bulbs 1.6 kW Xe lamps 19 kW xenon arc lamps

Tang, Ping

2013-01-01T23:59:59.000Z

414

Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards and Labeling Programs for Clothes Washers, Water Dispensers, Vending Machines and CFLs  

E-Print Network (OSTI)

top_runner//tr_fluorescent_light_bulb_jul.2009.pdf NiskinSubcommittee Final Report (bulb type fluorescent lamp). ”Fluorescent Lamps (CFLs) are an efficient lighting alternative to traditional incandescent light bulbs

Fridley, David

2010-01-01T23:59:59.000Z

415

CX-011406: Categorical Exclusion Determination  

Energy.gov (U.S. Department of Energy (DOE))

Notice of Proposed Rulemaking for Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps CX(s) Applied: B5.1 Date: 11/21/2013 Location(s): Nationwide Offices(s): Golden Field Office

416

ENERGY EFFICIENT LIGHTING PRODUCTS NOTICE (2011-04-25) i ENERGY EFFICIENT LIGHTING PRODUCTS  

E-Print Network (OSTI)

Measurements ______ 22/E12* IES LM-45:1991 Incandescent Lamps - Electrical Measurements ______ 22/E13* IES LM-45:2000 Incandescent Lamps - Electrical Measurements ______ 22/E13a* IES LM-45:2009 Incandescent

417

DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Manufacturer and Labeler to Cease Sale of Incandescent Reflector Lamps DOE Requires Manufacturer and Labeler to Cease Sale of Incandescent Reflector Lamps June 24, 2010 - 2:40pm...

418

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION CHECKLIST  

E-Print Network (OSTI)

Watts: 1. Type of luminaire (i.e.: post top, wall pack, surface, shoe box); for non-incandescent luminaires, indicate nominal lamp wattage and lamp type ( i.e.: fluorescent, incandescent, HID); ballast type. For incandescent luminaires, the lum

419

Energy Data Sourcebook for the U.S. Residential Sector  

E-Print Network (OSTI)

and Compact Fluorescent Bulbs Style Lamp Wattage Approximatebulbs is 112 TWh. If the PG&E survey's estimate of fluorescent (

Wenzel, T.P.

2010-01-01T23:59:59.000Z

420

Catalog of DC Appliances and Power Systems  

E-Print Network (OSTI)

loss for the compact fluorescent bulb replacement. For mosta light bulb or tube, a compact fluorescent lamp typically

Garbesi, Karina

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

iEMSs 2008:International Congress on Environmental Modelling and Software Integrating Sciences and Information Technology for Environmental Assessment and Decision Making  

E-Print Network (OSTI)

to be based on results from integrated Earth System Models (ESMs), C-LAMP is helping to establish the metadata

Hoffman, Forrest M.

422

GW RESIDENCE HALL HEALTH AND SAFETY KNOW WHAT'S PROHIBITED...  

E-Print Network (OSTI)

heaters · Halogen lamps · Sandwich makers/grills, hot plates, rice cookers, crock-pots, waffle makers

Vertes, Akos

423

Open Archive TOULOUSE Archive Ouverte (OATAO) OATAO is an open access repository that collects the work of Toulouse researchers and  

E-Print Network (OSTI)

phenomenon, provoking lamp arc instability, known as Acoustic Resonance (AR) [1-2]. Nowadays, commonly used in an HPS Lamp. (2013) IEEE Transactions on Industry Applications, vol. 49 (n° 3). pp. 1154-1160. ISSN 0093 Lamp A. Toumi, L. Chhun, S. Bhosle, G. Zissis and P. Maussion Université de Toulouse; UPS-INPT; LAPLACE

Mailhes, Corinne

424

518 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 33, NO. 2, APRIL 2005 Plasma Dynamics During Breakdown in  

E-Print Network (OSTI)

, lamp, modeling, plasma. METAL halide arc lamps are widely used sources of in- door and large area plasma hydrodynamics model was used to investigate breakdown in metal halide lamp. Images depicting518 IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 33, NO. 2, APRIL 2005 Plasma Dynamics During

Kushner, Mark

425

Source Four Ellipsoidal Series  

E-Print Network (OSTI)

parallel-blade U-ground connector -B two-pin and ground, 20 amp connector -c grounded, 20 amp, twistlock. to convert data when using any other HpL lamp, use the lumen or candela multiplying factors (Lm mf or cd mf) for that specific lamp, listed in the Lamps table in this datasheet. for lumen data, multiply by the Lm mf

Martin, Jeff

426

Vibronic origin of sulfur mass-independent isotope effect in photoexcitation of SO2 and the implications to the early earth’s atmosphere  

Science Journals Connector (OSTI)

...from ozone generated by an electric discharge or UV radiation (9, 10...radiation source (150-W Xe arc lamp) was used to excite SO 2 to the mixed 1...150-W UV-enhanced Xenon arc lamp (model 6254; Newport...using a 30-W deuterium arc lamp with a spectrometer...

Andrew R. Whitehill; Changjian Xie; Xixi Hu; Daiqian Xie; Hua Guo; Shuhei Ono

2013-01-01T23:59:59.000Z

427

Working Paper Sustainability and Innovation No. S 3/2014  

E-Print Network (OSTI)

efficient compact fluorescent lamps (CFLs) or light emitting diodes (LEDs) using a large nationally rebound effects associated with the switch from incandescent lamps (ILs) or halogen bulbs to more energy is decomposed into changes in lamp luminosity and burn time. On average, more efficient replace- ment bulbs

Paris-Sud XI, Université de

428

January 2002 LPipe ineKEEPING FACILITIES MANAGEMENT EMPLOYEES INFORMED  

E-Print Network (OSTI)

of Minnesota is changing the type of fluorescent lamps it purchases. The new bulbs contain about 60 percent has played a tremendous role in the success of this campus over the last ten years. Eric has led less mercury than regular lamps. The University collects fluorescent lamps from all of its campuses

Webb, Peter

429

Explosions in Coal Mines1  

Science Journals Connector (OSTI)

... compel, to exert themselves as keenly for the illumination of a murky, dirty coal-pit, as in the transformation of a plot of ground in South Kensington into fairyland. ... when the best safety lamps may be of little use, even if they continue to burn. Such electric lamps must indeed become formidable competitors of the Fleuss lamp (included in ...

1885-12-10T23:59:59.000Z

430

Office of Environmental Health and Safety The University of Texas at Austin  

E-Print Network (OSTI)

202 Austin, Texas 78712 (512) 471-3511; Fax: (512) 471-6918 INFO SHEET Fluorescent Light Bulb Disposal such as small lamps, mercury vapor lamps, and other odd shaped fluorescent tubes. In the case of smaller bulbs Used Fluorescent, high intensity discharge (HID), and UV germicidal lamps are considered a hazardous

431

PHYSICS DIVISION ESH BULLETIN 2004-01 1/5/04 OFFICES, SAFETY GUIDELINES  

E-Print Network (OSTI)

to these lamps. Energy Star® labeled torchiere floor lamps use compact fluorescent bulbs that burn much cooler fluorescent bulb which give the same amount of light as a 200 watt halogen bulb. Incidental Soldering. Most torchiere floor lamps use halogen bulbs that burn at temperatures exceeding 1,200 degrees F, hot

432

Presented at the 1998 ACEEE Summer Study on Energy Efficiency in Buildings, August 23-28, 1998, Pacific Grove, CA, and published in the Proceedings.  

E-Print Network (OSTI)

Incandescent Lamps: The International Experience Francis Rubinstein Building Technologies Department 22311-1772 March 1998 #12;1 Creating Markets For New Products To Replace Incandescent Lamps-in, energy-efficient replacement for the incandescent lamp. This paper summarizes the international

433

Author's personal copy Radiative heat transfer in enhanced hydrogen  

E-Print Network (OSTI)

tube and heated in a furnace or by an incandescent lamp. It was observed that hydrogen release from the glass sample was faster and stronger when heated by an incandescent lamp than within a furnace. Here and the glass samples. In brief, the radiation emitted by the incandescent lamp is concentrated between 0

Pilon, Laurent

434

Environmental and health aspects of lighting: Mercury  

SciTech Connect

Most discharge lamps, including fluorescent lamps, metal halide lamps, and high pressure sodium lamps, contain Mercury, a toxic chemical. Lighting professionals need to be able to respond to questions about the direct hazards of Mercury from accidentally breaking lamps, and the potential environmental hazards of lamp operation and disposal. We calculated the exposures that could occur from an accidental breakage of lamps. Acute poisoning appears almost impossible. Under some circumstances a sealed environment, such as a space station, could be contaminated enough to make it unhealthy for long-term occupation. Mercury becomes a potential environmental hazard after it becomes methylated. Mercury is methylated in aquatic environments, where it may accumulate in fish, eventually rendering them toxic to people and other animals. Lighting causes Mercury to enter the environment directly from lamp disposal, and indirectly from power plant emissions. The environmental tradeoffs between incandescent and discharge lamps depend upon the amounts released by these two sources, their local concentrations, and their probabilities of being methylated. Indirect environmental effects of lighting also include the release of other heavy metals (Cadmium, Lead and Arsenic), and other air pollutants and carbon dioxide that are emitted by fossil fuel power plants. For a given light output, the level of power plant emissions depends upon the efficacy of the light source, and is thus much larger for incandescent lamps than for fluorescent or discharge lamps. As disposal and control technologies change the relative direct and indirect emissions from discharge and incandescent lamps will change.

Clear, R.; Berman, S.

1993-07-01T23:59:59.000Z

435

PipelineJuly 2012 Volume 4, Issue 4 (From President Kaler's June 14 e-mail)  

E-Print Network (OSTI)

the LightEnergy Management seeks incandescent and T12 lamps Energy Management Senior Engineer Alicia inefficient light sources. Although the vast majority of the campus's number one offenders -- incandescent fluorescent lamps and classic incandescent A-lamps. T12's can be identified by their "fat" appearance (1

Webb, Peter

436

Colin Fink was a pioneer in electrochemical processing of materials. Fink is best known for his ground-breaking developments in the electro-deposi:on of metals, and par:cularly for  

E-Print Network (OSTI)

:le tungsten for incandescent lamp filaments, an insoluble anode used in the copper! ! Invented process to produce ductile tungsten for incandescent lamp filaments! ! Taught S. Ruben, who for incandescent lamp filaments! ! Taught S. Ruben, who invented alkaline baJery (Duracell Company

Columbia University

437

Sponsored by The Meyer Fund for Sustainable Development  

E-Print Network (OSTI)

incandescent bulbs 5. Photocell Output vs. Lamp Distance To investigate the photovoltaic (PV) cell output power dependence on the distance between the PV cell and an incandescent lamp. 6. Output Current between the PV cell and an incandescent lamp. Appendix C: Vocabulary Brief explanation of terminology

Oregon, University of

438

EA-1664: Finding of No Significant Impact | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Finding of No Significant Impact 4: Finding of No Significant Impact EA-1664: Finding of No Significant Impact Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Finding of No Significant Impact for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent

439

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High Intensity Discharge Lamps Test Procedures High Intensity Discharge Lamps Test Procedures Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is establishing test procedures for HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). ( 42 U.S.C. 6291-6309) This Rulemaking is related to the High-Intensity Discharge Lamps Standard and Test Procedure. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding test procedures for HID lamps. 76 FR 77914 (Dec. 15, 2011).

440

Lighting Research Group: Facilities: Integrating Sphere  

NLE Websites -- All DOE Office Websites (Extended Search)

Integrating Sphere Integrating Sphere integrating sphere Integrating Sphere Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer The integrating sphere is used to quickly measure the total light output of a lamp. The lamp being tested is placed in the center of the integrating sphere. At one side of the sphere is a light meter which measures the light output of the lamp. Between the lamp and the light meter there is a baffle to prevent the meter from seeing any direct light from the lamp. The inside of the sphere (including the baffle) is coated with a very white paint that reflects all wavelengths equally. This allows us to get very accurate measurements. The light from the lamp bounces around the sphere until it reaches the light meter. It is important that nothing else is in the sphere besides the lamp and the

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Metal Halide Lamp Fixtures Metal Halide Lamp Fixtures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of metal halide lamp fixtures since 2007. A metal halide lamp fixture uses a metal halide lamp and a metal halide lamp ballast. The lamp is the light source and the ballast starts and regulates current. Metal halide fixtures or lighting systems provide lighting for parking lots and streets, flood lighting, athletics facilities, big-box stores, and warehouses. The current standards will save approximately 6.4 quads of energy and result in approximately $9.6 billion in energy bill savings for products shipped from 2009-2038. The standard will avoid about 93.6 million metric tons of carbon dioxide emissions.

442

U.S. Department of Energy NEPA Categorical Exclusion Determination Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Reflector Lamps (RIN: 1904-AC15) Program or Field Office:EERE - Buildings Technology Program Location(s} (City/County/State): Nationwide Proposed Action Description: In this NQPR, DOE proposes to adopt new standards for the large diameter Incandescent Reflector Lamps (which will hereafter be referred to as certain "R, ER, and BR IRLs") include: (1) lamps rated 50 watts or less that are ER30, BR30, BR40, or ER40; (2) lamps rated 65 watts that are BR30, BR40, or ER40 lamps; and (3) R20 incandescent reflector lamps rated 45 watts or less. DOE also presents analysis for small diameter lamps and requests further comment on an appropriate standard for these products. The proposed standards, if adopted, would apply to all the

443

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Light Emitting Diode Lamps Light Emitting Diode Lamps Sign up for e-mail updates on regulations for this and other products There are currently no energy conservation standards for light emitting diode (LED) lamps.LED lamps are comprised of an LED source, such as LED packages or LED arrays; an LED driver; an American National Standards Institute (ANSI) standard base, and other optical, thermal, mechanical, and electrical components. These LED lamps are primarily used in residential applications as replacement lamps. The Department of Energy (DOE) will conduct an analysis of the energy, emissions, and costs associated with LEDs during any future energy conservation standard rulemakings. The Standards and Test Procedures for this product are related to Rulemaking for Light-Emitting Diode Lamps Test Procedure.

444

Comparative study of energy saving light sources  

Science Journals Connector (OSTI)

Techno-economic performance comparison of compact fluorescent lamps (CFL) with light emitting diodes (LED), electrode less fluorescent lamps (EEFL), fluorescent tubes, incandescent bulbs, photovoltaic (PV) and fiber optic lighting systems was carried out in view of worsening power and energy crisis in Pakistan. Literature survey showed 23 W CFL, 21 W EEFL, 18 W fluorescent tube or 15 W LED lamps emit almost same quantity of luminous flux (lumens) as a standard 100 W incandescent lamp. All inclusive, operational costs of LED lamps were found 1.21, 1.62. 1.69, 6.46, 19.90 and 21.04 times lesser than fluorescent tubes, CFL, EEFL, incandescent bulbs, fiber optic solar lighting and PV systems, respectively. However, tubes, LED, CFL and EEFL lamps worsen electric power quality of low voltage networks due to high current harmonic distortions (THD) and poor power factors (PF). Fluorescent lamps emit UV and pollute environment by mercury and phosphors when broken or at end of their life cycle. Energy consumption, bio-effects, and environmental concerns prefer LED lamps over phosphor based lamps but power quality considerations prefer EEFL. CFL and EEFL manufacturers claim operating temperatures in range of ?20 °C LED lamps may be five to ten times higher that high THD and low PF lamps. Choice of a lamp depends upon its current THD, PF, life span, energy consumption, efficiency, efficacy, color rendering index (CRI) and associated physical effects. This work proposes manufacturing and user level innovations to get rid of low PF problems. Keeping in view downside of phosphor based lamps our research concludes widespread adoption of LED lamps. Government and commercial buildings may consider full spectrum hybrid thermal photovoltaic and solar fiber optic illumination systems.

N. Khan; N. Abas

2011-01-01T23:59:59.000Z

445

Adjusted Distillate Fuel Oil Sales for Residential Use  

U.S. Energy Information Administration (EIA) Indexed Site

End Use/ Product: Residential - Distillate Fuel Oil Residential - No. 1 Residential - No. 2 Residential - Kerosene Commercial - Distillate Fuel Oil Commercial - No. 1 Distillate Commercial - No. 2 Distillate Commercial - No. 2 Fuel Oil Commercial - Ultra Low Sulfur Diesel Commercial - Low Sulfur Diesel Commercial - High Sulfur Diesel Commercial - No. 4 Fuel Oil Commercial - Residual Fuel Oil Commercial - Kerosene Industrial - Distillate Fuel Oil Industrial - No. 1 Distillate Industrial - No. 2 Distillate Industrial - No. 2 Fuel Oil Industrial - Low Sulfur Diesel Industrial - High Sulfur Diesel Industrial - No. 4 Fuel Oil Industrial - Residual Fuel Oil Industrial - Kerosene Farm - Distillate Fuel Oil Farm - Diesel Farm - Other Distillate Farm - Kerosene Electric Power - Distillate Fuel Oil Electric Power - Residual Fuel Oil Oil Company Use - Distillate Fuel Oil Oil Company Use - Residual Fuel Oil Total Transportation - Distillate Fuel Oil Total Transportation - Residual Fuel Oil Railroad Use - Distillate Fuel Oil Vessel Bunkering - Distillate Fuel Oil Vessel Bunkering - Residual Fuel Oil On-Highway - No. 2 Diesel Military - Distillate Fuel Oil Military - Diesel Military - Other Distillate Military - Residual Fuel Oil Off-Highway - Distillate Fuel Oil Off-Highway - Distillate F.O., Construction Off-Highway - Distillate F.O., Non-Construction All Other - Distillate Fuel Oil All Other - Residual Fuel Oil All Other - Kerosene Period:

446

Price of Motor Gasoline Through Retail Outlets  

Gasoline and Diesel Fuel Update (EIA)

Prices, Sales Volumes & Stocks by State Prices, Sales Volumes & Stocks by State (Dollars per Gallon Excluding Taxes) Data Series: Retail Price - Motor Gasoline Retail Price - Regular Gasoline Retail Price - Midgrade Gasoline Retail Price - Premium Gasoline Retail Price - Aviation Gasoline Retail Price - Kerosene-Type Jet Fuel Retail Price - Propane Retail Price - Kerosene Retail Price - No. 1 Distillate Retail Price - No. 2 Distillate Retail Price - No. 2 Fuel Oil Retail Price - No. 2 Diesel Fuel Retail Price - No. 4 Fuel Oil Prime Supplier Sales - Motor Gasoline Prime Supplier Sales - Regular Gasoline Prime Supplier Sales - Midgrade Gasoline Prime Supplier Sales - Premium Gasoline Prime Supplier Sales - Aviation Gasoline Prime Supplier Sales - Kerosene-Type Jet Fuel Prime Supplier Sales - Propane (Consumer Grade) Prime Supplier Sales - Kerosene Prime Supplier Sales - No. 1 Distillate Prime Supplier Sales - No. 2 Distillate Prime Supplier Sales - No. 2 Fuel Oil Prime Supplier Sales - No. 2 Diesel Fuel Prime Supplier Sales - No. 4 Fuel Oil Prime Supplier Sales - Residual Fuel Oil Stocks - Finished Motor Gasoline Stocks - Reformulated Gasoline Stocks - Conventional Gasoline Stocks - Motor Gasoline Blending Components Stocks - Kerosene Stocks - Distillate Fuel Oil Stocks - Distillate F.O., 15 ppm and under Sulfur Stocks - Distillate F.O., Greater than 15 to 500 ppm Sulfur Stocks - Distillate F.O., Greater 500 ppm Sulfur Stocks - Residual Fuel Oil Stocks - Propane/Propylene Period: Monthly Annual

447

Workbook Contents  

U.S. Energy Information Administration (EIA) Indexed Site

Kerosene-Type Jet Fuel Sales to End Users " Kerosene-Type Jet Fuel Sales to End Users " ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","Prices of Refiner Kerosene-Type Jet Fuel Sales to End Users ",60,"Monthly","9/2013","7/15/1975" ,"Release Date:","12/2/2013" ,"Next Release Date:","1/2/2014" ,"Excel File Name:","pet_pri_refoth_a_epjk_ptg_dpgal_m.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/pet/pet_pri_refoth_a_epjk_ptg_dpgal_m.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.gov"

448

Workbook Contents  

U.S. Energy Information Administration (EIA) Indexed Site

Kerosene by End Use" Kerosene by End Use" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","U.S. Adjusted Sales of Kerosene by End Use",6,"Annual",2012,"6/30/1984" ,"Release Date:","11/15/2013" ,"Next Release Date:","10/31/2014" ,"Excel File Name:","pet_cons_821kera_dcu_nus_a.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/pet/pet_cons_821kera_dcu_nus_a.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.gov" ,,"(202) 586-8800",,,"11/14/2013 4:22:05 PM"

449

Residential Buildings Historical Publications reports, data and housing  

Gasoline and Diesel Fuel Update (EIA)

Fuel Oil/Kerosene, 2001 Fuel Oil/Kerosene, 2001 Average Fuel Oil/Kerosene Residential Buildings Consumption Expenditures per Total per Square per per per Total Total Floorspace Building Foot per Household per Square per Household Households Number (billion (million (thousand Household Member Building Foot Household Member Characteristics (million) (million) sq. ft.) Btu) Btu) (million Btu) (million Btu) (dollars) (dollars) (dollars) (dollars) Total U.S. Households 11.2 9.4 26.0 80 29 67.1 26 723 0.26 607 236 Census Region and Division Northeast 7.1 5.4 16.8 111 36 84.7 33 992 0.32 757 297 New England 2.9 2.5 8.0 110 35 96.3 39 1,001 0.32 875 350 Middle Atlantic 4.2 2.8 8.8 112 36 76.6 30 984 0.32 675 260

450

2005 Residential Energy Consumption Survey  

U.S. Energy Information Administration (EIA) Indexed Site

G (2005) - Household Fuel Oil or Kerosene Usage Form G (2005) - Household Fuel Oil or Kerosene Usage Form OMB No. 1905-0092, Expiring May 31, 2008 Household Fuel Oil or Kerosene Usage Form Service Address: If the customer account number is not shown on the label, please enter it here. STEP 1 Customer Account: __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/ STEP 2 Now, please turn the page and answer the seven questions for the household identified above. Completed forms are due by March 4, 2006. If you have any questions, please call (toll-free) 1-NNN-NNN-NNNN. Ask for the Supplier Survey Specialist. This report is mandatory under Public Law 93-275, as amended. See the enclosed Answers to Frequently Asked Questions for more details concerning confidentiality and sanctions.

451

Workbook Contents  

U.S. Energy Information Administration (EIA) Indexed Site

Kerosene by End Use" Kerosene by End Use" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description","# Of Series","Frequency","Latest Data for" ,"Data 1","U.S. Total Sales of Kerosene by End Use",6,"Annual",2012,"6/30/1984" ,"Release Date:","11/15/2013" ,"Next Release Date:","10/31/2014" ,"Excel File Name:","pet_cons_821ker_dcu_nus_a.xls" ,"Available from Web Page:","http://www.eia.gov/dnav/pet/pet_cons_821ker_dcu_nus_a.htm" ,"Source:","Energy Information Administration" ,"For Help, Contact:","infoctr@eia.gov" ,,"(202) 586-8800",,,"11/14/2013 4:20:08 PM"

452

FAQs for Survey Form EIA-821  

Gasoline and Diesel Fuel Update (EIA)

21 21 What is the purpose of the EIA-821 survey? The EIA-821 survey is used to collect annual data on the sales of distillate and residual fuel oils, and kerosene to various categories of energy users at the state level. How is this data used? The data collected on the EIA-821 survey are used by EIA and the Department of Energy (DOE) in determining petroleum product supply and demand changes. In addition, the data are used by Federal, State, and local agencies, Congress, industry analysts, trade publications, academia, and the public to analyze, model and forecast petroleum product sales by state and energy use category. Where can I find published data from the EIA-821 survey? The annual data are published in the Fuel Oil and Kerosene Sales. The Fuel Oil and Kerosene Sales report provides information, illustrations

453

(1) Telegraphy (2) Continuous and Alternating Current Machinery An Elementary Text—book for use in Technical Schools (3) Laboratory Manual, Direct and Alternating Current (4) Transmission Line Formulas for Electrical Engineers and Engineering Students (5) Wireless Telegraphy (6) Incandescent Electric Lamps and Their Application  

Science Journals Connector (OSTI)

... the various kinds of electrical machinery now in use. Although the treatment is of an elementary kind and includes very few formulas, it is very thorough. It discusses all the ... special circumstances we should never think of using i io—volt mains for measuring the resistance of a yard or two of wire or of the armature of a dynamo, ...

DAVID ROBERTSON

1914-10-08T23:59:59.000Z

454

Northeastern Rural E M C | Open Energy Information  

Open Energy Info (EERE)

Northeastern Rural E M C Northeastern Rural E M C Jump to: navigation, search Name Northeastern Rural E M C Place Indiana Utility Id 20603 Utility Location Yes Ownership C NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting Energy: Ballasted Lamps 1000W Lighting Outdoor Lighting Energy: Ballasted Lamps 100W Lighting Outdoor Lighting Energy: Ballasted Lamps 150W Lighting Outdoor Lighting Energy: Ballasted Lamps 175W Lighting Outdoor Lighting Energy: Ballasted Lamps 200W Lighting Outdoor Lighting Energy: Ballasted Lamps 250W Lighting

455

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps Energy Conservation Standard High-Intensity Discharge Lamps Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is considering establishing energy conservation standards for certain HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). (42 USC 6311-6317) Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of public meeting and availability of interim technical support document regarding energy conservation standards for high-intensity discharge lamps. 78 FR 13566 (February 28, 2013).

456

Lighting Research Group: Facilities: Power Analyzer  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Analyzer Power Analyzer Power Analyzer power analyzer Gonio-photometer | Integrating sphere | Power analyzer | Spectro-radiometer A power analyzer is a very necessary tool for lighting research. With the power analyzer we are able to monitor the input voltage to the lamp as well as the input power and current. The amount of power a lamp or a lamp-ballast combination uses is very important when determining its efficiency. It is also important to monitor the input voltage to make sure it doesn't vary. This can affect the light output of a lamp greatly. With the power analyzer we can also measure things like the power factor, harmonic distortion, and current crest factor of some lamps. These measurements tell us how well a lamp is working. For example, a high power

457

City of Beresford, South Dakota (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Beresford, South Dakota (Utility Company) Beresford, South Dakota (Utility Company) Jump to: navigation, search Name City of Beresford Place South Dakota Utility Id 1601 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Dusk to Dawn Lighting Service- (1000W Lamp) Lighting Dusk to Dawn Lighting Service- (100W Lamp) Lighting Dusk to Dawn Lighting Service- (150W Lamp) Lighting Dusk to Dawn Lighting Service- (250W Lamp) Lighting Dusk to Dawn Lighting Service- (400W Lamp) Lighting Dusk to Dawn Lighting Service- (70W Lamp) Lighting

458

CX-007850: Categorical Exclusion Determination | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

850: Categorical Exclusion Determination 850: Categorical Exclusion Determination CX-007850: Categorical Exclusion Determination Notice of Proposed Rulemaking for Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Reflector Lamps CX(s) Applied: B5.1 Date: 01/09/2012 Location(s): Nationwide Offices(s): Energy Efficiency and Renewable Energy In this Notice of Proposed Rulemaking (NOPR), DOE proposes to adopt new standards for the large diameter Incandescent Reflector Lamps (which will hereafter be referred to as certain "R, ER, and BR IRLs") include: (1) lamps rated 50 watts or less that are ER30, BR30, BR40, or ER40; (2) lamps rated 65 watts that are BR30, BR40, or ER40 lamps; and (3) R20 incandescent reflector lamps rated 45 watts or less. DOE also presents analysis for

459

Source Four Ellipsoidal Series  

E-Print Network (OSTI)

Parallel-blade U-ground connector -B Two-pin and ground, 20 amp connector -C grounded, 20 amp, twistlock lamp, use the lumen or candela multiplying factors (Lm mF or Cd mF) for that specific lamp, listed in the Lamps table in this datasheet. For lumen data, multiply by the Lm mF. For candela or footcandle data

Martin, Jeff

460

Measurement of optical efficiency of fluorescent luminaires  

SciTech Connect

By controlling the lamp wall temperature of fluorescent lamps with a Peltier device, the optical efficiency of luminaires can be measured directly. Measurements of the fixture efficiency for a luminaire can vary by over 8% depending upon the lamp-ballast system used in the measurement. The authors suggest that optical efficiency may be an improved metric for evaluating fixture designs. 6 refs., 3 figs., 5 tabs.

Verderber, R.R.; Morse, O.; Rubinstein, F.; Siminovitch, M.

1987-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

SUPPLEMENTARY INFORMATION FOR Increased Robustness of Single-Molecule Counting with Microfluidics,  

E-Print Network (OSTI)

Chips / dRT-LAMP amplification of HIV-1 RNA on SlipChip Page S9 ­ Real-time RT-LAMP amplification of HIV-1 for RT-LAMP amplification of HIV viral RNA selected from a previous publication1 with several single BIP TAT TGC ACC AGG CCA GAT GAT TTT GTA CTA GTA GTT CCT GCT ATG p24 FIP CAG CTT CCT CAT TGA TGG TCT

Ismagilov, Rustem F.

462

Use Patterns of LED Flashlights in Kenya and a One-Year Cost Analysis of Flashlight Ownership  

SciTech Connect

Flashlight usage is widespread across much of sub-Saharan Africa.1 In Kenya in particular, over half of all households report owning a flashlight (Kamfor, 2002). Aside from household use, flashlights are also widely used to perform income-earning jobs in Kenya. Lumina Research Note No.4, the first report in this series documenting flashlight use in Kenya, highlights flashlight use patterns of night watchmen and bicycle taxi drivers. Both of these are occupations that rely on the use of flashlights on a nightly basis (Tracy et al., 2009). Also highlighted by Research Note No.4, flashlight users in Kenya have reported being highly dissatisfied with the quality of the low-cost LED flashlights that are available, and they identify several reoccurring problems they have faced as flashlight end-users (Tracy et al., 2009). The fact that there exists a substantial dependency upon flashlights in Kenya and that users are disgruntled with the available products suggests reasons for concern about flashlight quality. This concern is present despite two recent technological transitions in the flashlight market. First, LED technology has quickly emerged as the dominant source of portable lighting in Kenya, outpacing incandescent flashlights (Johnstone et al., 2009). LED technology has the potential to provide efficiency and performance benefits relative to incandescent bulbs, and low-cost LEDs have achieved price levels that make them cost competitive with conventional lighting sources for a number of applications (Mills, 2005). Second, rechargeable sealed-lead acid (SLA) batteries are also becoming more prevalent alternatives to disposable dry cell batteries. Flashlights using rechargeable SLA batteries tend to have a lower total cost of ownership over a two-year period than a flashlight using dry cell batteries (Radecsky, 2009); however, as this current report highlights, this may vary depending on the intensity of use patterns. To avoid a potential market spoiling effect for off-grid lighting products based on LED technology (Mills and Jacobson, 2008; Lighting Africa, 2007) a better understanding of flashlight use-patterns is crucial (Tracy et al., 2009). In addition, the economic implications faced by rural flashlight end-users provide further incentive for a move toward higher quality low-cost flashlights. In this report, our team uses interviews with 46 end users of flashlights to collect information about their use patterns and costs associated with owning and operating flashlight products. While flashlights used in their portable mode typically do not represent a substitute for kerosene or other forms of fuel-based lighting, at times they are used in stationary applications in place of a fuel-based lamp. In either case, these products often represent end users first exposure to LED technology and rechargeable dry cell batteries, and thus stand to either provide a positive or negative impression of these technologies for a diversity of lighting applications.

Tracy, Jennifer; Jacobson, Arne; Mills, Evan

2010-02-16T23:59:59.000Z

463

,"Energy Source","State Energy Data System","Annual/Monthly Energy Review"  

U.S. Energy Information Administration (EIA) Indexed Site

A. Comparison of fuel detail for the State Energy Data System and the Annual and Monthly Energy Review data systems" A. Comparison of fuel detail for the State Energy Data System and the Annual and Monthly Energy Review data systems" ,"Energy Source","State Energy Data System","Annual/Monthly Energy Review" "Consumption Sector","Category","Fuel Detail","Fuel Detail" "Residential ","Coal","Coal","Coal" "Residential ","Natural Gas","Natural Gas","Natural Gas" "Residential ","Petroleum","Distillate Fuel","Distillate Fuel" "Residential ","Petroleum","Kerosene","Kerosene" "Residential ","Petroleum","LPG","LPG"

464

The effect of wettability on capillary pressure and oil recovery  

E-Print Network (OSTI)

Electric Motor Core Holder Figure 2. Core Cutter Condenser Graduated Tube Core Thinb]e Toluene Electric Heater Figure 3. Extraction Apparatus 13 The extracted core plugs were dried in a Precision Scientific drying oven, set and maintained at 212... P e Volume cc Core No. Kerosene Water Kerosene Water All A12 Bll B12 Cll C12 Dll D12 A21 A22 821 822 C21 C22 D21 D22 A31 A32 831 B32 C31 C32 D31 D32 5. 689 5. 608 5. 665 5. 482 5. 298 5. 255 5. 628 5. 372 5. 536 5...

Chon, Bohyun

2012-06-07T23:59:59.000Z

465

Reading Municipal Light Department - Business Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reading Municipal Light Department - Business Lighting Rebate Reading Municipal Light Department - Business Lighting Rebate Program Reading Municipal Light Department - Business Lighting Rebate Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Commercial Customers: $10,000 per calendar year Municipal Customers: $15,000 per calendar year Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount T-8/T-5 Lamp with Electronic Ballasts: $11 - $35/fixture Interior High Output Lamp with Electronic Ballasts: $100/fixture De-lamping: $4 - $9/lamp Lighting Sensors: $20/sensor LED Exit Signs: $20/fixture Provider Incentive Programs

466

EA-1881: Energy Conservation Program: Energy Conservation Standards for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81: Energy Conservation Program: Energy Conservation Standards 81: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts Summary This EA evaluates the environmental impacts of a proposal to amend energy conservation standards for various consumer products and certain commercial and industrial equipment, including fluorescent lamp ballasts. Public Comment Opportunities No public comment opportunities available at this time. Documents Available for Download October 20, 2011 EA-1881: Finding of No Significant Impact Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011) October 5, 2011 EA-1881: Final Environmental Assessment Energy Conservation Program: Energy Conservation Standards for Fluorescent

467

Buildings Energy Data Book: 7.6 Efficiency Standards for Lighting  

Buildings Energy Data Book (EERE)

2 2 Efficiency Standards for Incandescent Reflector Lamps (1) Effective for lamps manufactured after November 1, 1995 and before July 14, 2012 Minimum Nominal Average Lamp Lamp Wattage Efficacy (lm/W) 40-50 10.5 51-66 11.0 67-85 12.5 86-115 14.0 116-155 14.5 156-205 15.0 Effective for lamps manufactured on or after July 14, 2012 Minimum Rated Lamp Rated Average Lamp Lamp Wattage Lamp Spectrum Diameter (in) Voltage (V) Efficacy (lm/W) (2) 40-205 Standard Spectrum >2.5 ≥125 6.8*P^0.27 40-205 Standard Spectrum >2.5 <125 5.9*P^0.27 40-205 Standard Spectrum ≤2.5 ≥125 5.7*P^0.27 40-205 Standard Spectrum ≤2.5 <125 5.0*P^0.27 40-205 Modified Spectrum >2.5 ≥125 5.8*P^0.27 40-205 Modified Spectrum >2.5 <125 5.0*P^0.27 40-205 Modified Spectrum ≤2.5 ≥125 4.9*P^0.27

468

HISTORICAL PERSPECTIVE ON HETEROGENEOUS GAS-PARTICLE INTERACTION  

E-Print Network (OSTI)

-- the physics and chemistry of matter. Practical: Rate of sublimation of tungsten lamp filaments. Practical Chemistry Program #12;OUTLINE Interfacial mass flux Detailed balance ­ The Hertz

Schwartz, Stephen E.

469

Apparatus for isotopic alteration of mercury vapor  

DOE Patents (OSTI)

An apparatus for enriching the isotopic Hg content of mercury is provided. The apparatus includes a reactor, a low pressure electric discharge lamp containing a fill including mercury and an inert gas. A filter is arranged concentrically around the lamp. In a preferred embodiment, constant mercury pressure is maintained in the filter by means of a water-cooled tube that depends from it, the tube having a drop of mercury disposed in it. The reactor is arranged around the filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of a material which is transparent to ultraviolet light.

Grossman, Mark W. (Belmont, MA); George, William A. (Gloucester, MA); Marcucci, Rudolph V. (Danvers, MA)

1988-01-01T23:59:59.000Z

470

Photochemistry of Methyl Bromide on the ?-Cr2O3(0001) Surface...  

NLE Websites -- All DOE Office Websites (Extended Search)

desorption (PSD). Irradiation of adsorbed CH3Br with broad band light from a Hg arc lamp resulted in both photodesorption and photodecomposition of the parent molecule at...

471

E-Print Network 3.0 - approaches neoadjuvant chemotherapy Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

of optical spectroscopy in early monitoring of neo-adjuvant... chemotherapy Xenon Arc Lamp + Monochromator Collection Fibers In vivo Breast Tissue Illumination Fibers Imaging...

472

E-Print Network 3.0 - aspiration biopsy diagnosis Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

OPTICAL BIOPSY EX VIVO MARGIN ASSESSMENT Quantitative Optical Physiology "Toolbox" Xenon Arc Lamp Source: Ramanujam, Nimmi - Department of Biomedical Engineering, Duke University...

473

Microsoft Word - DOE-ID-14-067 MesoCoat EC B3-6.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

Title: Functionally Gradient Transition Joint for Dissimilar Metal Welding using Plasma Arc Lamps- MesoCoat, Inc. SECTION B. Project Description MesoCoat, Inc. will conduct...

474

Features Index - ORNL Review - Vol. 41, No. 2, 2008  

NLE Websites -- All DOE Office Websites (Extended Search)

and control intense lighting in the lab coming from the world's most powerful plasma arc-based lamp. More... Under Extreme Pressure Achieving the pressure at Earth's...

475

Notes  

Science Journals Connector (OSTI)

... concrete, 37; phonograph, 37; incandescent electric lamp, 35; steam turbine, 34; electric car, 34; calculating machine, 33; internal-combustion engine, 33.

1913-11-20T23:59:59.000Z

476

No such thing as society : : art and the crisis of the European welfare state  

E-Print Network (OSTI)

context. Besides the mobile biogas system, Superflex hasa lamp, a radio station and a biogas production unit. Almostof this fact, Supergas, the biogas unit, bares striking

Lookofsky, Sarah Elsie

2009-01-01T23:59:59.000Z

477

Energy Department Announces $4 Million Solicitation for Solid...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

fluorescent lamps. SSL sources are already replacing conventional technologies in automobile brake lights, traffic signals, exit signs and flashlights. The solid-state lighting...

478

Collaboration  

NLE Websites -- All DOE Office Websites (Extended Search)

field sites and case studies of mogul-base LED lamps. Working group to develop national standards for data reports from advanced lighting controls (future CEE subcommittee)....

479

Modelling of Radiative Transfer in Light Sources  

E-Print Network (OSTI)

. . . . . . . . . . . . . . . 30 2.5.3 Temperature distribution . . . . . . . . . . . . . . . . . . . . . . . . . 32 2-X radiative transition that is responsible for the sulfur lamp's bright sun-like spectrum #12;Contents 1

Eindhoven, Technische Universiteit

480

Guiding Market Introduction of High-Performance SSL Products...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Program Fact Sheet guidingmarketfactsheetsept2013.pdf More Documents & Publications LED T8 Replacement Lamps DOE Lighting Program Update: LED Validation Activities Solid State...

Note: This page contains sample records for the topic "wick-fed lamps kerosene" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Energy Department Announces Next Phase of L Prize® Competition...  

Office of Environmental Management (EM)

The competition announced today will spur leading-edge companies to build innovative LED replacements for conventional parabolic aluminized reflector (PAR 38) lamps, commonly...

482

B O N N E V I L L E P O W E R A D M I N I S T R A T I O N  

NLE Websites -- All DOE Office Websites (Extended Search)

May 2013 Commercial & Industrial Lighting LED Retrofits for Troffers LED retrofit kits and linear replacement lamps are now avail- able to convert recessed fluorescent light...

483

Data:F4be6666-f245-48c1-b5a5-88c79d2a1476 | Open Energy Information  

Open Energy Info (EERE)

Lamp 100 Watts Sector: Lighting Description: This rate applies to accounting schedule 444 Street lights. Source or reference: http:www.pioneerelectric.coopdocuments...

484

Data:E91e4129-ff68-4098-854b-46b777bdc22f | Open Energy Information  

Open Energy Info (EERE)

Lamp 175 Watts Sector: Lighting Description: This rate applies to accounting schedule 444 Street lights. Source or reference: http:www.pioneerelectric.coopdocuments...

485

High-performance LED street lighting using microlens arrays  

Science Journals Connector (OSTI)

An efficient LED lamp that illuminates the street with high quality is presented. The luminaire shows high optical efficiency, high optical utilization factor, low glare, and...

Lee, Xuan-Hao; Moreno, Ivan; Sun, Ching-Cherng

2013-01-01T23:59:59.000Z

486

Data:6bfaf28c-faad-4298-b9e5-315309a16859 | Open Energy Information  

Open Energy Info (EERE)

Lamp 150 Watts Sector: Lighting Description: This rate applies to accounting schedule 444 Street lights. Source or reference: http:www.pioneerelectric.coopdocuments...

487

Data:B20cef55-4517-4bad-b99f-f313cf45418d | Open Energy Information  

Open Energy Info (EERE)

Lamp 400 Watts Sector: Lighting Description: This rate applies to accounting schedule 444 Street lights. Source or reference: http:www.pioneerelectric.coopdocuments...

488

PhiladelphiAmble  

E-Print Network (OSTI)

and Fitz, tree-lined, street light sheds a modest orange onstars, light specks washed dim from the rusted street lamp

Schall, Daniel

2014-01-01T23:59:59.000Z

489

Licht- und Beleuchtungstechnik, Elektrowärmegeräte  

Science Journals Connector (OSTI)

Elektrische Lampen (Glühlampen und Gasentladungslampen) wandeln elektrische Energie in Lichtenergie um. Eine elektrische Beleuchtungseinrichtung besteht aus der Lampe als Lichtquelle und der Leuchte. Die Leuch...

Hille; Schneider; Großmann; Lensch

1991-01-01T23:59:59.000Z

490

Work-piece alignment for a hybrid multi-axis laser-aided manufacturing system .  

E-Print Network (OSTI)

??"The Laser Aided Manufacturing Process (LAMP) is a multi-axis hybrid manufacturing process comprised of both an additive process, laser deposition, and a subtractive process, CNC… (more)

Panackal, Ajay

2006-01-01T23:59:59.000Z

491

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Test Results roomairconditioner v1.6.xlsx More Documents & Publications Commercial Air Conditioners and Heat Pumps Fluorescent Lamp Ballasts Residential Condensing Gas Furnaces...

492

Most Viewed Documents for Biology and Medicine: September 2014...  

Office of Scientific and Technical Information (OSTI)

Robert Hayes (2008) 16 Defining the Effectiveness of UV Lamps Installed in Circulating Air Ductwork Douglas VanOsdell; Karin Foarde (2002) 15 Toxicity and physical properties of...

493

September 2013 Most Viewed Documents for Biology And Medicine...  

Office of Scientific and Technical Information (OSTI)

Cramer, E. (1997) 16 > Defining the Effectiveness of UV Lamps Installed in Circulating Air Ductwork Douglas VanOsdell; Karin Foarde (2002) 16 > Synthesis of Polycyclic Natural...

494

July 2013 Most Viewed Documents for Biology And Medicine | OSTI...  

Office of Scientific and Technical Information (OSTI)

1994 NONE (1995) 39 > Defining the Effectiveness of UV Lamps Installed in Circulating Air Ductwork Douglas VanOsdell; Karin Foarde (2002) 32 > Mesoporous Silica Nanomaterials...

495

Plant-wide Systems | Department of Energy  

Energy Savers (EERE)

Outdoor Area Lighting LED T8 Replacement Lamps Demonstration Assessment of Light-Emitting Diode (LED) Freezer Case Lighting 2010 U.S. Lighting Market Characterization Building...

496

Effect of mechanical vibrations on light emitting diode luminaires.  

E-Print Network (OSTI)

??In this work, a LED and two types of Compact fluorescent lamps were investigated for the intensity variation due to mechanical vibrations in the range… (more)

Paladugu, Jayalakshmi

2009-01-01T23:59:59.000Z

497

Chapter 6, Residential Lighting Evaluation Protocol: The Uniform...  

Office of Environmental Management (EM)

STAR lighting fixtures. More recently, programs are introducing solid-state light-emitting diode (LED) lamps. The future of savings claims from residential lighting programs is...

498

Nationwide Professional Skills Training Program - Presolicitation...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

isotope in each container. Materials disposed of included radium-226, cobalt-60, strontium-90, promethium-147, phosphorus-32, fission products, heat lamps, and beryllium...

499

Data:Dc5cbc5d-73c0-4b83-9363-aabc0684d3fd | Open Energy Information  

Open Energy Info (EERE)

and Regulations. APPLICABILITY: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaires and poles conforming to...

500

Data:E3f4ce5f-059c-48a2-8bf9-377f80f3ad2d | Open Energy Information  

Open Energy Info (EERE)

and Regulations. APPLICABILITY: Applicable only for dusk to dawn lighting by means of photo-electric controlled, ballast operated vapor lamp luminaires and poles conforming to...