Powered by Deep Web Technologies
Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Kinetics of wet sodium vapor complex plasma  

SciTech Connect

In this paper, we have investigated the kinetics of wet (partially condensed) Sodium vapor, which comprises of electrons, ions, neutral atoms, and Sodium droplets (i) in thermal equilibrium and (ii) when irradiated by light. The formulation includes the balance of charge over the droplets, number balance of the plasma constituents, and energy balance of the electrons. In order to evaluate the droplet charge, a phenomenon for de-charging of the droplets, viz., evaporation of positive Sodium ions from the surface has been considered in addition to electron emission and electron/ion accretion. The analysis has been utilized to evaluate the steady state parameters of such complex plasmas (i) in thermal equilibrium and (ii) when irradiated; the results have been graphically illustrated. As a significant outcome irradiated, Sodium droplets are seen to acquire large positive potential, with consequent enhancement in the electron density.

Mishra, S. K., E-mail: nishfeb@rediffmail.com [Institute for Plasma Research (IPR), Gandhinagar 382428 (India); Sodha, M. S. [Centre of Energy Studies, Indian Institute of Technology Delhi (IITD), New Delhi 110016 (India)] [Centre of Energy Studies, Indian Institute of Technology Delhi (IITD), New Delhi 110016 (India)

2014-04-15T23:59:59.000Z

2

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and HID (high-intensity discharge) lamps and all other mercury containing labeled for shipment to a recycling plant for mercury, glass and aluminum recovery. The beneficial re

Baker, Chris I.

3

0 min 2 4 0 min 2 4 Watts Watts  

E-Print Network (OSTI)

0 min 2 4 0 min 2 4 Watts Watts Time 0 min 2 4 Watts Time TRADEOFFS POWER Jonathan Pearce Advisor D'load IDLE CPU WAVELAN 1.0 .43 1.3 Watts #12;

Smailagic, Asim

4

Discovery of Sodium and Potassium Vapor in the Atmosphere of the Moon  

Science Journals Connector (OSTI)

...lunar atmosphere: Solar-wind implantation and subsequent release of sodium, solar wind-driven sputtering of sodium...internal release. Solar-wind implantation can only supply...near the south pole at large local solar zenith angles suggests...

A. E. Potter; T. H. Morgan

1988-08-05T23:59:59.000Z

5

GEORGE WATTS HILL ALUMNI CENTER  

E-Print Network (OSTI)

BR IN KH O U S- BU LLITT CHILLER BUILDING F KENAN STADIUM GEORGE WATTS HILL ALUMNI CENTER EHRINGHAUS

North Carolina at Chapel Hill, University of

6

Definition: Watt | Open Energy Information  

Open Energy Info (EERE)

Watt Watt Jump to: navigation, search Dictionary.png Watt A unit of measure for power, which measures the rate of energy conversion; equal to one joule per second (or 1/746 horsepower); equivalent to one ampere under a pressure of one volt.[1][2] View on Wikipedia Wikipedia Definition The watt' is a derived unit of power in the International System of Units (SI), named after the Scottish engineer James Watt (1736-1819). The unit, defined as one joule per second, measures the rate of energy conversion or transfer. Also Known As W Related Terms Electricity, Power, Kilowatt References ↑ http://www.eia.gov/tools/glossary/index.cfm?id=W#watt ↑ http://needtoknow.nas.edu/energy/glossary/ Retri LikeLike UnlikeLike You like this.Sign Up to see what your friends like. eved from

7

Symbolic Symbolic Computation Stephen M. Watt  

E-Print Network (OSTI)

Symbolic Symbolic Computation Stephen M. Watt University of Western Ontario London, Ontario, Canada www.csd.uwo.ca/watt Abstract Symbolic mathematical computation has become an important tool

Watt, Stephen M.

8

PlotWatt | Open Energy Information  

Open Energy Info (EERE)

PlotWatt PlotWatt Jump to: navigation, search Tool Summary LAUNCH TOOL Name: PlotWatt Agency/Company /Organization: PlotWatt Sector: Energy Focus Area: Energy Efficiency Resource Type: Software/modeling tools User Interface: Mobile Device Website: plotwatt.com/ Country: United States Web Application Link: plotwatt.com/ Cost: Free OpenEI Keyword(s): Green Button Apps Northern America Language: English PlotWatt Screenshot References: PlotWatt[1]PlotWatt FAQ[2] Logo: PlotWatt PlotWatt helps you to save money and energy, instead of getting hit with high energy bills every month. PlotWatt shows you exactly where to save. Overview PlotWatt's algorithms analyze home energy consumption to figure out spending at the appliance level and figure out how to cost effectively save

9

Partial Pressure of Saturated Sodium Nitrite Vapor over the System NaNO2-NaNO3  

Science Journals Connector (OSTI)

The partial pressure of sodium nitrite was measured in the system NaNO2-NaNO3...at temperatures of 798, 823, and 848 K and the logarithm of the NaNO2 pressure was obtained as a function of inverse temperature. Th...

V. I. Glazov; G. P. Dukhanin; M. Kh. Dkhaibe

2004-02-01T23:59:59.000Z

10

NSCU, September 2004 Duke's Milly Watt Project  

E-Print Network (OSTI)

1 NSCU, September 2004 Duke's Milly Watt Project Carla Ellis Faculty · Alvin Lebeck · Amin Vahdat-power hardware? Milly Watt Motivation #12;2 NSCU, September 2004 Energy should be a "first class" resource energy goals Milly Watt Vision NSCU, September 2004 Energy Management Spectrum · Re-examine interactions

Ellis, Carla

11

Oben: Die Station im Watt bei Spiekeroog.  

E-Print Network (OSTI)

Oben: Die Station im Watt bei Spiekeroog. Unten: Ausschnitt des innen begeh- baren Pfahlrohrs mit Ossietzky Universität Oldenburg Meeresdaten rund um die Uhr: Die Station im Watt Von Rainer Reuter In autumn Rückseiten- watt und offener Nordsee. Die Umwelt zu beobachten und verläss- liche Messungen zu gewinnen, ist

Oldenburg, Carl von Ossietzky Universität

12

WattQuiz | Open Energy Information  

Open Energy Info (EERE)

WattQuiz WattQuiz Jump to: navigation, search Tool Summary LAUNCH TOOL Name: WattQuiz Agency/Company /Organization: Genability Sector: Energy Focus Area: Energy Efficiency Resource Type: Software/modeling tools User Interface: Website Website: www.wattquiz.com/ Country: United States Web Application Link: www.wattquiz.com/ Cost: Free Northern America Language: English WattQuiz Screenshot References: Genability[1] NYC Open Data[2] Donors Choose[3] Logo: WattQuiz A social quiz on energy usage that donates proceeds to charity via DonorsChoose.org. Questions are powered by Genability APIs. Overview WattQuiz is a simple social quiz, a la freerice.com, that asks you questions and educates you about your energy. Correct answers generate watts that are donated to worthy charities via DonorsChoose.org!

13

Goodbye, Watts. Hello, LUMENS! | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Goodbye, Watts. Hello, LUMENS! Goodbye, Watts. Hello, LUMENS! Goodbye, Watts. Hello, LUMENS! May 17, 2012 - 2:21pm Addthis John Chu John Chu Communications Specialist with the Office of Energy Efficiency and Renewable Energy For years, I bought light bulbs based on watts, or energy use. Like many light bulb consumers, I looked for a traditional 40, 60, 75, or 100 watt incandescent bulb. Now that stores today carry more and more energy efficient lighting choices, I wanted to replace my old incandescents with new bulbs to save energy and money on my electricity bill. But in shopping for the right bulb, I came across a challenge in looking for bulbs based on watts. Since these newer bulbs use less energy, I found bulbs that use 8, 15, or 26 watts. The wattages are pretty close to each other, but the

14

Tennessee Nuclear Profile - Watts Bar Nuclear Plant  

U.S. Energy Information Administration (EIA) Indexed Site

Watts Bar Nuclear Plant" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

15

Award of James Watt International Medal  

Science Journals Connector (OSTI)

... THE Council of the Institution of Mechanical Engineers has unanimously awarded the James Watt International Medal to Mr. A. G. M. Michell, of ... the bicentenary of the birth of James Watt on January 19, 1736, and is awarded every two years to an engineer of any nationality who is deemed worthy of the ...

1942-06-06T23:59:59.000Z

16

MagLab - Pioneers in Electricity and Magnetism: James Watt  

NLE Websites -- All DOE Office Websites (Extended Search)

James Watt (1736-1819) James Watt The Scottish instrument maker and inventor James Watt had a tremendous impact on the shape of modern society. His improvements to the steam engine...

17

SciTech Connect: Thermodynamic and transport properties of sodium...  

Office of Scientific and Technical Information (OSTI)

on thermophysical properties of sodium have been included in this critical assessment. Thermodynamic properties of sodium liquid and vapor that have been assessed...

18

Watt Does It Cost To Use It?  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Watt Does It Cost to Use It? Grades: 5-8, 9-12 Topic: Energy Efficiency and Conservation Author: Mark Ziesmer Owner: Alliance to Save Energy This educational material is brought to...

19

TerraWatt Power | Open Energy Information  

Open Energy Info (EERE)

TerraWatt Power TerraWatt Power Jump to: navigation, search Name TerraWatt Power Place Schenectady, New York Zip 12305-1036 Product American manufacturer of micro-inverters, subsidiary of Advanced Energy Conversion. Coordinates 42.81226°, -73.941026° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.81226,"lon":-73.941026,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

20

AstroWatt | Open Energy Information  

Open Energy Info (EERE)

AstroWatt AstroWatt Jump to: navigation, search Name AstroWatt Place Austin, Texas Sector Solar Product Texas-based venture backed company developing a proprietary solar cell technology. Coordinates 30.267605°, -97.742984° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.267605,"lon":-97.742984,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

AlphaWatt Ltd | Open Energy Information  

Open Energy Info (EERE)

AlphaWatt Ltd AlphaWatt Ltd Jump to: navigation, search Name AlphaWatt Ltd Place London, United Kingdom Zip EC1V 4PY Sector Solar Product Solar project developer, plans to become an independent power provider. Coordinates 51.506325°, -0.127144° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":51.506325,"lon":-0.127144,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

22

GlobalWatt Inc | Open Energy Information  

Open Energy Info (EERE)

GlobalWatt Inc GlobalWatt Inc Jump to: navigation, search Name GlobalWatt Inc Place Dover, Delaware Zip 19801 Product Shell company, once planned to float on AIM to raise money in order to acquire the business of semiconductor and/or PV manufacturing equipment suppliers. Coordinates 42.67954°, -88.110374° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.67954,"lon":-88.110374,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

23

WASTE TO WATTS Waste is a Resource!  

E-Print Network (OSTI)

WASTE TO WATTS Waste is a Resource! energy forum Case Studies from Estonia, Switzerland, Germany Bossart,· ABB Waste-to-Energy Plants Edmund Fleck,· ESWET Marcel van Berlo,· Afval Energie Bedrijf From Waste to Energy To Energy from Waste #12;9.00-9.30: Registration 9.30-9.40: Chairman Ella Stengler opens

Columbia University

24

PERFORMANCE RIGHTS FOR SOFTWARE Mark Perry Stephen M. Watt  

E-Print Network (OSTI)

1 PERFORMANCE RIGHTS FOR SOFTWARE Mark Perry Stephen M. Watt Department of Computer Science University of Western Ontario London Ontario, Canada N6A 5B7 {markp,watt}@csd.uwo.ca ABSTRACT As we use

Watt, Stephen M.

25

Symbolic Polynomials with Sparse Exponents Stephen M. Watt  

E-Print Network (OSTI)

Symbolic Polynomials with Sparse Exponents Stephen M. Watt Ontario Research Centre for Computer Algebra Department of Computer Science, University of Western Ontario London Ontario, CANADA N6A 5B7 watt

Watt, Stephen M.

26

Functional Decomposition of Symbolic Polynomials Stephen M. Watt  

E-Print Network (OSTI)

Functional Decomposition of Symbolic Polynomials Stephen M. Watt Ontario Research CentreB7 watt@uwo.ca Abstract Earlier work has presented algorithms to factor and compute GCDs of symbolic

Watt, Stephen M.

27

Improving Pen-Based Mathematical Interfaces Stephen Watt  

E-Print Network (OSTI)

Improving Pen-Based Mathematical Interfaces Stephen Watt Computer Science Department, The University of Western Ontario, Canada watt@scl.csd.uwo.ca Abstract Pen-based user interfaces offer

Watt, Stephen M.

28

Type Specialization in Aldor Laurentiu Dragan and Stephen M. Watt  

E-Print Network (OSTI)

Type Specialization in Aldor Laurentiu Dragan and Stephen M. Watt Computer Science Department The University of Western Ontario London, Canada {ldragan,watt}@csd.uwo.ca Abstract. Computer algebra

Watt, Stephen M.

29

Post Facto Type Extension for Mathematical Programming Stephen M. Watt  

E-Print Network (OSTI)

Post Facto Type Extension for Mathematical Programming Stephen M. Watt Department of Computer Science University of Western Ontario London ON, Canada N6A 5B7 watt@csd.uwo.ca Abstract We present

Watt, Stephen M.

30

Generalization in Maple Cosmin Oancea Clare So Stephen M. Watt  

E-Print Network (OSTI)

Generalization in Maple Cosmin Oancea Clare So Stephen M. Watt Ontario Research Centre for Computer {coancea,clare,watt}@orcca.on.ca Abstract We explore the notion of generalization in the setting

Watt, Stephen M.

31

BOUNDED PARALLELISM IN COMPUTER ALGEBRA Stephen Michael Watt  

E-Print Network (OSTI)

BOUNDED PARALLELISM IN COMPUTER ALGEBRA by Stephen Michael Watt A thesis presented in Computer Science Waterloo, Ontario, 1985 c S.M. Watt 1985 #12;Permission has been granted to the National

Watt, Stephen M.

32

Garbage Collecting the World Wide Web Stephen M. Watt  

E-Print Network (OSTI)

Garbage Collecting the World Wide Web Stephen M. Watt Western University London, Ontario, Canada N6A 5B7 Stephen.Watt@uwo.ca Abstract The World Wide Web has grown over the past decade and a half from

Watt, Stephen M.

33

An Analytic Model for Colluding Processes Stephen M. Watt  

E-Print Network (OSTI)

An Analytic Model for Colluding Processes Stephen M. Watt University of Western Ontario London, Canada www.csd.uwo.ca/watt Abstract--We develop a quantitative framework in order to understand how

Watt, Stephen M.

34

Pivot-Free Block Matrix Inversion Stephen M. Watt  

E-Print Network (OSTI)

Pivot-Free Block Matrix Inversion Stephen M. Watt Ontario Research Centre for Computer Algebra Department of Computer Science University of Western Ontario London Ontario, CANADA N6A 5B7 watt

Watt, Stephen M.

35

PERFORMANCE RIGHTS FOR SOFTWARE Mark Perry & Stephen M. Watt  

E-Print Network (OSTI)

1 PERFORMANCE RIGHTS FOR SOFTWARE Mark Perry & Stephen M. Watt Department of Computer Science University of Western Ontario London Ontario, Canada N6A 5B7 {markp,watt}@csd.uwo.ca ABSTRACT As we use

Perry, Mark

36

Watts, Qian, and Tracey 1 Multivariate OI correlation functions  

E-Print Network (OSTI)

Watts, Qian, and Tracey 1 APPENDIX Multivariate OI correlation functions The optimal interpolation to indicate its dependent variable. #12; Watts, Qian, and Tracey 2 As an example of using this extension

Rhode Island, University of

37

James A. Spudich and Susan Watt PROTEOLYTIC FRAGMENTS OF  

E-Print Network (OSTI)

James A. Spudich and Susan Watt MYOSIN PROTEOLYTIC FRAGMENTS OF COMPLEX WITH ACTIN THE PROTEOLYTlC l?RAGMEKTS OF MYOSLN (Received for publication, March 19, 1971) JAMES h. SPUDICH* AXD Susm WATT

Spudich, James A.

38

Development of a 100-Watt High Temperature Thermoelectric Generator  

Energy.gov (U.S. Department of Energy (DOE))

Test results for low and high temperature thermoelectric generators (TEG) those for a 530-watt BiTe TEG; design and construction of a 100-watt high temperature TEG currently in fabrication.

39

Goodbye, Watts. Hello, Lumens. (High-Resolution EPS Billboard...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EPS Billboard) Goodbye, Watts. Hello, Lumens. (High-Resolution EPS Billboard) High-resolution EPS of billboard reading, 'Goodbye Watts. Hello Lumens. The new way to shop for light....

40

Goodbye, Watts. Hello, Lumens. (High-Resolution JPG Billboard...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hello Lumens. The new way to shop for light. Energysaver.gov DoEBillboardGoodbyeWatts.jpg More Documents & Publications Goodbye, Watts. Hello, Lumens. (High-Resolution EPS...

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Context Sensitive Mathematical Character Recognition Elena Smirnova Stephen M. Watt  

E-Print Network (OSTI)

Context Sensitive Mathematical Character Recognition Elena Smirnova Stephen M. Watt Ontario Research Centre for Computer Algebra The University of Western Ontario London Ontario, Canada {elena,watt handwritten mathematical expressions. Watt and Xie [5, 6] have studied methods to improve the performance

Watt, Stephen M.

42

GIDL User Guide Cosmin Oancea and Stephen M. Watt  

E-Print Network (OSTI)

GIDL User Guide Cosmin Oancea and Stephen M. Watt Ontario Research Centre for Computer Algebra one is "Parametric Polymorphism for Software Component Architectures", by Oancea and Watt [6 language bindings. The paper "Generic Library Extension in a Heterogeneous Environment", by Oancea and Watt

Watt, Stephen M.

43

Writing on Clouds Vadim Mazalov and Stephen M. Watt  

E-Print Network (OSTI)

Writing on Clouds Vadim Mazalov and Stephen M. Watt Department of Computer Science The University of Western Ontario London Ontario, Canada N6A 5B7 {vmazalov,Stephen.Watt}@uwo.ca Abstract. While writer. Watt In our classification paradigm, a character is represented by the coefficients of an approximation

Watt, Stephen M.

44

Watts Professorship of Psychology in association with Wolfson College  

E-Print Network (OSTI)

1 Watts Professorship of Psychology in association with Wolfson College Outline of the post The University intends to make an appointment to the Watts Professorship of Psychology with effect from 1 October Sciences Board's current expectation is that the incoming Watts Professor will become Head of Department

Oxford, University of

45

Watts, Oklahoma: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Watts, Oklahoma: Energy Resources Watts, Oklahoma: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 36.1092487°, -94.5702202° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.1092487,"lon":-94.5702202,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

46

Shanghai Solar Watt Ltd | Open Energy Information  

Open Energy Info (EERE)

Solar Watt Ltd Solar Watt Ltd Jump to: navigation, search Name Shanghai Solar-Watt Ltd Place Shanghai, Shanghai Municipality, China Zip 200040 Sector Renewable Energy, Solar, Wind energy Product Providing photovoltaic systems, solar air heating systems, solar water pumping systems, wind energy systems (small), photovoltaic module manufacturing equipment and renewable energy system batteries. Coordinates 31.247709°, 121.472618° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":31.247709,"lon":121.472618,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

47

Development of a 500 Watt High Temperature Thermoelectric Generator...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

More Documents & Publications Development of a 100-Watt High Temperature Thermoelectric Generator Automotive Waste Heat Conversion to Power Program Automotive Waste Heat...

48

Development of a 500 Watt High Temperature Thermoelectric Generator  

Energy.gov (U.S. Department of Energy (DOE))

A low temperature TEG has been built and tested providing over 500 watts electric power at a ?T of 2000C

49

Development of a 100-Watt High Temperature Thermoelectric Generator...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Generator Development of a 100-Watt High Temperature Thermoelectric Generator Test results for low and high temperature thermoelectric generators (TEG) those for a...

50

Lower Watts Bar Reservoir Clinch River/Poplar Creek  

Energy.gov (U.S. Department of Energy (DOE))

This document explains the cleanup activities and any use limitations for the land surrounding the Lower Watts Bar Reservoir Clinch River/Poplar Creek.

51

Watts, Qian, and Tracey 1 1. Leveling and Mapping  

E-Print Network (OSTI)

Watts, Qian, and Tracey 1 1. Leveling and Mapping Accurate maps of the daily pressure and current other sites, giving \\Delta s P 0 (s) = \\Delta s p(t; s) \\Gamma \\Delta s P 0 (t; s), (1) #12; Watts, Qian

Rhode Island, University of

52

Watt parameters for the Los Alamos Model : Subroutine getab  

E-Print Network (OSTI)

Many neutron transport Monte-Carlo codes can randomly sample fission neutron energies from a Watt spectrum. The quality of simulations depends on how well the Watt spectrum represents the true energy spectrum of the fission neutrons, and on one's choice of the Watt parameters a and b. The energy spectra of fission neutrons have been calculated and tabulated for the neutron induced fission of 235,238U and 239Pu as a function of incoming neutron energy by Madland using the Los Alamos Model. Each of these energy spectra are mapped into time-of-flight space and fitted with a Watt spectrum. A subroutine getab has been written to interpolate these results, so that Watt a and b parameters can be estimated for all incoming neutron energies up to ~16 MeV.

Lestone, J P

2014-01-01T23:59:59.000Z

53

Watt parameters for the Los Alamos Model : Subroutine getab  

E-Print Network (OSTI)

Many neutron transport Monte-Carlo codes can randomly sample fission neutron energies from a Watt spectrum. The quality of simulations depends on how well the Watt spectrum represents the true energy spectrum of the fission neutrons, and on one's choice of the Watt parameters a and b. The energy spectra of fission neutrons have been calculated and tabulated for the neutron induced fission of 235,238U and 239Pu as a function of incoming neutron energy by Madland using the Los Alamos Model. Each of these energy spectra are mapped into time-of-flight space and fitted with a Watt spectrum. A subroutine getab has been written to interpolate these results, so that Watt a and b parameters can be estimated for all incoming neutron energies up to ~16 MeV.

J. P. Lestone

2014-09-18T23:59:59.000Z

54

Trico Electric Cooperative - SunWatts Incentive Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Trico Electric Cooperative - SunWatts Incentive Program Trico Electric Cooperative - SunWatts Incentive Program Trico Electric Cooperative - SunWatts Incentive Program < Back Eligibility Commercial Residential Savings Category Solar Buying & Making Electricity Heating & Cooling Water Heating Maximum Rebate PV systems 10 kW or smaller: 30% of the total system cost Program Info State Arizona Program Type Utility Rebate Program Rebate Amount PV systems 10 kW or smaller: $0.10/watt DC PV greater than 10 kW up to 1 MW: Performance-Based Incentive (competitive bid process) Solar water heaters: $0.40 per expected first year kWh savings Provider Trico Electric Cooperative, Inc. Through the SunWatts Program, Trico Electric Cooperative offers residential and business customers a rebate for installing photovoltaic (PV) systems

55

Kill-a-Watt Contest at UCF | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kill-a-Watt Contest at UCF Kill-a-Watt Contest at UCF Kill-a-Watt Contest at UCF April 2, 2010 - 5:16pm Addthis The University of Central Florida has created an innovative way to save energy and money on campus through a new dorm-based competition called "Kill-a-Watt". Students representing campus residence halls compete against each other to achieve energy savings and can receive up to $200 in scholarships. Watch how former DOE intern and current UCF DOE Campus Ambassador, Chris Castro, is spearheading this exciting effort and learn more about energy saving tips that students find useful like proper thermostat set points and reducing plug load. Read the DoE's press release about the video. Addthis Related Articles University of Central Florida Students' Energy Saving Work Showcased in New

56

Goodbye, Watts. Hello, Lumens. (Low-Resolution Billboard) | Department...  

Energy Savers (EERE)

Hello Lumens. The new way to shop for light. Energysaver.gov DoEBillboardGoodbyeWattsweb.jpg More Documents & Publications Goodbye, Watts. Hello, Lumens. (High-Resolution JPG...

57

Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington SUMMARY This EA evaluates the environmental impacts associated with the U.S. Department of Energy proposed action to conduct a lead test assembly program to confirm the viability of using a commercial light water reactor to produce tritium. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD July 22, 1997 EA-1210: Finding of No Significant Impact Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington July 22, 1997 EA-1210: Final Environmental Assessment

58

Thermophysical Properties of Sodium Nitrate and Sodium Chloride  

Office of Scientific and Technical Information (OSTI)

Thermophysical Properties of Sodium Nitrate and Sodium Chloride Thermophysical Properties of Sodium Nitrate and Sodium Chloride Solutions and Their Effects on Fluid Flow in Unsaturated Media Tianfu Xu and Karsten Pruess Earth Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 ABSTRACT. Understanding movement of saline sodium nitrate (NaNO 3 ) waste solutions is important for assessing the contaminant migration near leaking waste storage tanks in the unsaturated zone at the Hanford site (Washington, USA). The purpose of this study is to contribute a basic understanding of effects of the thermophysical behavior of NaNO 3 solutions on fluid flow in unsaturated media. We first present mathematical expressions for the dependence of density, viscosity, solubility and vapor pressure of

59

New River Light & Power Co | Open Energy Information  

Open Energy Info (EERE)

New River Light & Power Co New River Light & Power Co Place North Carolina Utility Id 13482 Utility Location Yes Ownership S NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt SV TOB Lighting 150 Watt SV TOB Lighting 150 Watt Sodium Vapor Lighting 175 Watt MV TOB Lighting 175 Watt Mercury Vapor Lighting 250 Watt Metal Halide Lighting 250 Watt SV TOB Lighting 250 Watt Sodium Vapor Lighting 400 Watt MV TOB Lighting 400 Watt Mercury Vapor Lighting 400 Watt Metal Halide Lighting 400 Watt SV TOB Lighting 750 Watt SV TOB Lighting

60

VP 100: Retooling Michigan -- Yachts and Watts | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

VP 100: Retooling Michigan -- Yachts and Watts VP 100: Retooling Michigan -- Yachts and Watts VP 100: Retooling Michigan -- Yachts and Watts June 18, 2010 - 4:13pm Addthis Energetx Composites was able to purchase equipment such as this mold for utility-scale wind turbine blades thanks to a Recovery Act grant that matched the company’s $3.5 million investment. | Photo Courtesy of Energetx | Energetx Composites was able to purchase equipment such as this mold for utility-scale wind turbine blades thanks to a Recovery Act grant that matched the company's $3.5 million investment. | Photo Courtesy of Energetx | Joshua DeLung Near the eastern shore of Lake Michigan, there's a shift taking place. Tiara Yachts makes fiber composite structures for boats. Now the Holland, Mich.-based company is transforming part of its factory and using its 30

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Coherent population trapping on the sodium D1 line in high magnetic fields  

Science Journals Connector (OSTI)

We consider the coherent-population-trapping (CPT) phenomenon in a sodium atomic vapor. The experiment leading to the first observation of CPT is revisited with an improved...

Hller, R; Renzoni, F; Windholz, L; Xu, J H

1997-01-01T23:59:59.000Z

62

A Note on the Functional Decomposition of Symbolic Polynomials Stephen M. Watt  

E-Print Network (OSTI)

A Note on the Functional Decomposition of Symbolic Polynomials Stephen M. Watt Ontario Research, CANADA N6A 5B7 watt@uwo.ca It often arises that the general form of a polynomial is known

Watt, Stephen M.

63

Online Recognition of Multi-Stroke Symbols with Orthogonal Series Oleg Golubitsky Stephen M. Watt  

E-Print Network (OSTI)

Online Recognition of Multi-Stroke Symbols with Orthogonal Series Oleg Golubitsky Stephen M. Watt Department of Computer Science University of Western Ontario London, Ontario, Canada N6A 5B7 {ogolubit,watt

Watt, Stephen M.

64

Content-Faithful Stylesheets for MathML Igor Rodionov Stephen M. Watt  

E-Print Network (OSTI)

Content-Faithful Stylesheets for MathML Igor Rodionov Stephen M. Watt Ontario Research Centre for Computer Algebra Department of Computer Science University of Western Ontario London Ontario, Canada {igor,watt

Watt, Stephen M.

65

Report on the SNAP minisymposium at Siam '98 Robert M. Corless and Stephen M. Watt  

E-Print Network (OSTI)

Report on the SNAP minisymposium at Siam '98 Robert M. Corless and Stephen M. Watt Department6A 5B7 Rob.Corless@uwo.ca, Stephen.Watt@uwo.ca July, 1998 1 Background In the essay [10], Nick

Watt, Stephen M.

66

SPARSE EXPONENTS IN SYMBOLIC POLYNOMIALS MATTHEW MALENFANT AND STEPHEN M. WATT  

E-Print Network (OSTI)

SPARSE EXPONENTS IN SYMBOLIC POLYNOMIALS MATTHEW MALENFANT AND STEPHEN M. WATT Abstract. We.M. WATT The algorithms fall into two families: algebraic extension methods and projec- tion methods

Watt, Stephen M.

67

Generic Library Extension in a Heterogeneous Environment Cosmin Oancea Stephen M. Watt  

E-Print Network (OSTI)

Generic Library Extension in a Heterogeneous Environment Cosmin Oancea Stephen M. Watt Department of Computer Science The University of Western Ontario London Ontario, Canada N6A 5B7 {coancea,watt

Watt, Stephen M.

68

Hybrid Mathematical Symbol Recognition using Support Vector Machines Birendra Keshari and Stephen M. Watt  

E-Print Network (OSTI)

. Watt Department of Computer Science University of Western Ontario London, Ontario, Canada N6A 5B7 {bkeshari,watt}@orcca.on.ca Abstract Recognition of mathematical symbols is a challenging task, with a large

Watt, Stephen M.

69

Aspects of Mathematical Expression Analysis in Arabic Handwriting Elena Smirnova and Stephen M. Watt  

E-Print Network (OSTI)

. Watt Ontario Research Centre for Computer Algebra The University of Western Ontario London, ON, N6A5B7, Canada e-smirnova@ti.com, watt@orcca.on.ca Abstract We address the question of recognizing handwritten

Watt, Stephen M.

70

Streaming-Archival InkML Conversion Birendra Keshari and Stephen M. Watt  

E-Print Network (OSTI)

Streaming-Archival InkML Conversion Birendra Keshari and Stephen M. Watt Dept. of Computer Science University of Western Ontario London, Ontario, Canada N6A 5B7 {bkeshari,watt}@csd.uwo.ca Abstract Ink Markup

Watt, Stephen M.

71

InkChat: A Collaboration Tool for Mathematics Rui Hu and Stephen M. Watt  

E-Print Network (OSTI)

InkChat: A Collaboration Tool for Mathematics Rui Hu and Stephen M. Watt The University of Western Ontario London Ontario, Canada N6A 5B7 {rhu8,Stephen.Watt}@uwo.ca Abstract. We investigate the question

Watt, Stephen M.

72

Digital Ink Compression via Functional Approximation Vadim Mazalov and Stephen M. Watt  

E-Print Network (OSTI)

Digital Ink Compression via Functional Approximation Vadim Mazalov and Stephen M. Watt University of Western Ontario London, Ontario, Canada vmazalov@csd.uwo.ca, watt@csd.uwo.ca Abstract Representing digital

Watt, Stephen M.

73

Linear Compression of Digital Ink via Point Selection Vadim Mazalov and Stephen M. Watt  

E-Print Network (OSTI)

Linear Compression of Digital Ink via Point Selection Vadim Mazalov and Stephen M. Watt Ontario, Canada vmazalov@uwo.ca, Stephen.Watt@uwo.ca Abstract--We present a method to compress digital ink based

Watt, Stephen M.

74

A Context for Pen-Based Mathematical Computing Elena Smirnova Stephen M. Watt  

E-Print Network (OSTI)

A Context for Pen-Based Mathematical Computing Elena Smirnova Stephen M. Watt Ontario Research, Canada N6A 5B7 {elena,watt}@orcca.on.ca Abstract We report on an investigation to determine

Watt, Stephen M.

75

Performance Analysis of Generics in Scientific Computing Laurentiu Dragan Stephen M. Watt  

E-Print Network (OSTI)

Performance Analysis of Generics in Scientific Computing Laurentiu Dragan Stephen M. Watt Ontario Research Centre for Computer Algebra University of Western Ontario London, Ontario, Canada N6A 5B7 {ldragan,watt

Watt, Stephen M.

76

A Structure for Adaptive Handwriting Recognition Vadim Mazalov and Stephen M. Watt  

E-Print Network (OSTI)

A Structure for Adaptive Handwriting Recognition Vadim Mazalov and Stephen M. Watt Department of Computer Science University of Western Ontario London, Canada {vmazalov, Stephen.Watt}@uwo.ca Abstract We

Watt, Stephen M.

77

A Collaborative Interface for Multimodal Ink and Audio Documents Amit Regmi and Stephen M. Watt  

E-Print Network (OSTI)

A Collaborative Interface for Multimodal Ink and Audio Documents Amit Regmi and Stephen M. Watt Department of Computer Science University of Western Ontario London, Ontario, Canada N6A 5B7 {aregmi,watt

Watt, Stephen M.

78

An Approach to Mathematical Notation Selection Elena Smirnova, Stephen M. Watt  

E-Print Network (OSTI)

An Approach to Mathematical Notation Selection Elena Smirnova, Stephen M. Watt Ontario Research Centre for Computer Algebra, The University of Western Ontario E-mail: {alena, watt}@orcca.on.ca (Demo

Watt, Stephen M.

79

RECOGNITION FOR LARGE SETS OF HANDWRITTEN MATHEMATICAL SYMBOLS Stephen M. Watt and Xiaofang Xie  

E-Print Network (OSTI)

RECOGNITION FOR LARGE SETS OF HANDWRITTEN MATHEMATICAL SYMBOLS Stephen M. Watt and Xiaofang Xie Dept. of Computer Science University of Western Ontario London Ontario, Canada N6A 5B7 {watt

Watt, Stephen M.

80

A Technique for Generic Iteration and Its Optimization Stephen M. Watt  

E-Print Network (OSTI)

A Technique for Generic Iteration and Its Optimization Stephen M. Watt Department of Computer Science University of Western Ontario London Ontario, Canada N6A 5B7 watt@csd.uwo.ca Abstract Software

Watt, Stephen M.

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

John C. Mitani David Watts The evolution of non-maternal caretaking among anthropoid primates  

E-Print Network (OSTI)

John C. Mitani · David Watts The evolution of non-maternal caretaking among anthropoid primates: do (1997) 40: 213 ­ 220 © Springer-Verlag 1997 J.C. Mitani (&) · David Watts1 Department of Anthropology

82

Processes Coupling the Upper and Deep Ocean on the Continental Slope D. Randolph Watts  

E-Print Network (OSTI)

Processes Coupling the Upper and Deep Ocean on the Continental Slope D. Randolph Watts Graduate-pronged approach has required a combination of expertise from R. Watts, G. Sutyrin, and I. Ginis (who have

Rhode Island, University of

83

Letter-based speech synthesis Oliver Watts, Junichi Yamagishi, Simon King  

E-Print Network (OSTI)

Letter-based speech synthesis Oliver Watts, Junichi Yamagishi, Simon King Centre for Speech Technology Research, University of Edinburgh, UK O.S.Watts@sms.ed.ac.uk jyamagis@inf.ed.ac.uk Simon

Edinburgh, University of

84

Name of the University: HeriotWatt University Names of the students: Katrn Emma Ammendrup  

E-Print Network (OSTI)

Name of the University: HeriotWatt University Names of the students: Katrín Emma Ammendrup Exchange semester: Fall, 2013 Faculty: At HeriotWatt: Built Environment, Civil Engineering. At RU: Science

Karlsson, Brynjar

85

Processes Coupling the Upper and Deep Ocean on the Continental Slope D. Randolph Watts  

E-Print Network (OSTI)

Processes Coupling the Upper and Deep Ocean on the Continental Slope D. Randolph Watts Graduate of expertise from R. Watts, G. Sutyrin, and I. Ginis (who have a coordinated ONR-supported study at URI

Rhode Island, University of

86

A Comparative Evaluation of Three Mobile Languages Heriot-Watt University  

E-Print Network (OSTI)

A Comparative Evaluation of Three Mobile Languages Zara Field Heriot-Watt University Edinburgh, Scotland E-mail: zf1@macs.hw.ac.uk P. W. Trinder Heriot-Watt University Edinburgh, Scotland E-mail: trinder

Trinder, Phil

87

Bruce G. Terrell, Gordon P. Watts & Timothy J. Runyan The Search For Planter  

E-Print Network (OSTI)

May 2014 Bruce G. Terrell, Gordon P. Watts & Timothy J. Runyan The Search For Planter The Ship Design & Layout: Matt McIntosh, ONMS; Liz.Liang, ONMS #12;May 2014 Bruce G. Terrell, Gordon P. Watts

88

Call for Presentations The GPGPU Continuum from mWatts to peta flops  

E-Print Network (OSTI)

Call for Presentations SAVE the DATE The GPGPU Continuum from mWatts to peta flops Organizing on using GPUs as part of mobile devices, which limits the power consumption of the GPU to mWatts. We

Schuster, Assaf

89

AVTA: GE Energy WattStation AC Level 2 Charging System Testing...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

GE Energy WattStation AC Level 2 Charging System Testing Results AVTA: GE Energy WattStation AC Level 2 Charging System Testing Results The Vehicle Technologies Office's Advanced...

90

Evidence of Bottom-Trapped Currents in the Kuroshio Extension Region STUART P. BISHOP AND D. RANDOLPH WATTS  

E-Print Network (OSTI)

. RANDOLPH WATTS Graduate School of Oceanography, University of Rhode Island, Narragansett, Rhode Island JAE trapping (Thompson and Luyten 1976; Hogg 1981; Johns and Watts 1986; Hogg 2000). Johns and Watts (1986

Rhode Island, University of

91

Online Stroke Modeling for Handwriting Recognition Oleg Golubitsky Stephen M. Watt  

E-Print Network (OSTI)

Online Stroke Modeling for Handwriting Recognition Oleg Golubitsky Stephen M. Watt Department of Computer Science University of Western Ontario London Ontario, Canada N6A 5B7 {oleg,watt Stephen M. Watt and Oleg Gol- ubitsky. Permission to copy is hereby granted provided the original

Watt, Stephen M.

92

Programming Language Concepts and Paradigms David A Watt 3-1 Solutions to Exercises 3  

E-Print Network (OSTI)

Programming Language Concepts and Paradigms © David A Watt 3-1 Solutions to Exercises 3 3 lifetime of p lifetime of i #12;Programming Language Concepts and Paradigms © David A Watt 3-2 3) call return #12;Programming Language Concepts and Paradigms © David A Watt 3-3 ** 3.7.2 A possible

Watt, David A.

93

Optimization of Point Selection on Digital Ink Curves Rui Hu and Stephen M. Watt  

E-Print Network (OSTI)

Optimization of Point Selection on Digital Ink Curves Rui Hu and Stephen M. Watt Computer Science Department University of Western Ontario London, Canada rhu8@uwo.ca, Stephen.Watt@uwo.ca Abstract Digital ink. In 2012, Mazalov and Watt [6] described a piecewise linear ap- proximation algorithm to compress digital

Watt, Stephen M.

94

Programming Language Concepts and Paradigms David A Watt 2-1 Solutions to Exercises 2  

E-Print Network (OSTI)

Programming Language Concepts and Paradigms © David A Watt 2-1 Solutions to Exercises 2 2 and Paradigms © David A Watt 2-2 function not (b: Boolean) return Boolean is begin if b then return false; else ::= ... | { Expression ( , Expression )* } #12;Programming Language Concepts and Paradigms © David A Watt 2-3 2

Watt, David A.

95

INVERTED ECHO SOUNDER DEVELOPMENT G. F. Chaplin and D. Randolph Watts  

E-Print Network (OSTI)

INVERTED ECHO SOUNDER DEVELOPMENT G. F. Chaplin and D. Randolph Watts Graduate School thermocline. Watts (1975), in discussing IES data from MODE I, showed that changes in dynamic height can evolving since its initial development. The first multi- instrument deployment was in MODE I (Watts

Rhode Island, University of

96

Cache Size in a Cost Model for Heterogeneous Skeletons Heriot-Watt University, Edinburgh,  

E-Print Network (OSTI)

Cache Size in a Cost Model for Heterogeneous Skeletons K.A. Armih Heriot-Watt University, Edinburgh, Scotland, UK kaa41@hw.ac.uk G.J. Michaelson Heriot-Watt University, Edinburgh, Scotland, UK G.Michaelson@hw.ac.uk P.W. Trinder Heriot-Watt University, Edinburgh, Scotland, UK P.W.Trinder@hw.ac.uk Abstract High

Trinder, Phil

97

Einzigartige energiesparende Lsungen mit einem Stromverbrauch von 0,0 Watt im Standby und  

E-Print Network (OSTI)

Einzigartige energiesparende Lösungen mit einem Stromverbrauch von 0,0 Watt im Standby und ECO,9 cm (22 Zoll) TFT Bildschirm 0-Watt-Energiesparmodus Datenblatt Ausgabedatum April 2009 Genie?en Sie Merkmale IPS (In Plane Switching), 0 Watt im Energiesparmodus, ECO-Taste, ECO-Status-LED: 3 Farben für 3

Ott, Albrecht

98

Name of the University: Heriot-Watt University Names of the student: Andri Mr Reynisson  

E-Print Network (OSTI)

Name of the University: Heriot-Watt University Names of the student: Andri Már Reynisson Exchange ­ very short Heriot-Watt University is based in Riccarton, just outside Edinburgh in Scotland. The school faculty divisions and special areas. These are the schools at Heriot-Watt Universtity: School

Karlsson, Brynjar

99

Einzigartige energiesparende Lsungen mit einem Stromverbrauch von 0,0 Watt im Standby und  

E-Print Network (OSTI)

Einzigartige energiesparende Lösungen mit einem Stromverbrauch von 0,0 Watt im Standby und ECO P Line mit 0-Watt-Energiesparmodus DaTEnBLaTT Ausgabedatum Oktober 2009 Genie?en Sie die perfekte dieses 66 cm (26 Zoll)-Widescreen-Displays der P Line. #12;P26W-5 ECO IPS Besondere Merkmale 0 Watt im

Ott, Albrecht

100

WattProbe: Automatic Learning of Hardware Energy Models Manish Prasad  

E-Print Network (OSTI)

WattProbe: Automatic Learning of Hardware Energy Models Manish Prasad CSE 629 Project Report be the ability to do so without the cumbersome use of externally connected measurement devices. Watt like multi­meters for measurement would be extremely desirable. WattProbe precisely tar­ gets this goal

Chiueh, Tzi-cker

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Towards Better Performance Per Watt in Virtual Environments on Asymmetric Single-ISA Multi-core  

E-Print Network (OSTI)

Towards Better Performance Per Watt in Virtual Environments on Asymmetric Single-ISA Multi, performance-asymmetric multicore architec- tures, performance per watt 1. INTRODUCTION Asymmetric single performance per watt than homogeneous multicore proces- sors. As power consumption in data centers becomes

Fedorova, Alexandra

102

Clinical and Experimental Optometry 88.5 September 2005 Retinal remodelling Jones, Watt and Marc  

E-Print Network (OSTI)

Clinical and Experimental Optometry 88.5 September 2005 282 Retinal remodelling Jones, Watt defects). Even though all these INVITED REVIEW Retinal remodelling Bryan W Jones PhD Carl B Watt Ph and Experimental Optometry 88.5 September 2005 283 Retinal remodelling Jones, Watt and Marc dystrophies

Marc, Robert E.

103

Processes Coupling the Upper and Deep Ocean on the Continental Slope D. Randolph Watts  

E-Print Network (OSTI)

Processes Coupling the Upper and Deep Ocean on the Continental Slope D. Randolph Watts Graduate / modeling) approach requires a combination of expertise from R. Watts, G. Sutyrin, and I. Ginis (who have in a published journal article (Logoutov, Sutyrin and Watts, 2001). These results are being used by Ginis

Rhode Island, University of

104

Denver Watts to Water | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Denver Watts to Water Denver Watts to Water Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In this section How can we help you? Build an energy program Improve building and plant performance Earn the ENERGY STAR and other recognition Benchmark energy use ENERGY STAR in action Communicate and educate ENERGY STAR communications toolkit Bring Your Green to Work with ENERGY STAR

105

Watts Community, Oklahoma: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Watts Community, Oklahoma: Energy Resources Watts Community, Oklahoma: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 36.035006°, -94.5727598° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.035006,"lon":-94.5727598,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

106

White LED Benchmark of 65 Lumens Per Watt Achieved  

Energy.gov (U.S. Department of Energy (DOE))

Novel chip design and the balance of multiple interrelated design parameters have enabled Cree, Inc.'s Santa Barbara Technology Center to demonstrate white LEDs with efficacies greater than 65 lumens per watt at 350 mA. The results are particularly significant because they were achieved with a pre-production prototype chip using the same package used in Cree's commercially available XLamp 7090 high power LED, rather than a laboratory device.

107

Propagation of Kuroshio Extension Meanders between 143 and 149E KAREN L. TRACEY, D. RANDOLPH WATTS, AND KATHLEEN A. DONOHUE  

E-Print Network (OSTI)

WATTS, AND KATHLEEN A. DONOHUE Graduate School of Oceanography, University of Rhode Island, Narragansett

Rhode Island, University of

108

City of Elizabethton, Tennessee (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Elizabethton, Tennessee (Utility Company) Elizabethton, Tennessee (Utility Company) Jump to: navigation, search Name City of Elizabethton Place Tennessee Utility Id 5763 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Lighting 1000 Watt Mercury Vapor Lighting 1000 Watt Metal Halide Lighting 150 Watt High Pressure Sodium Lighting 175 Watt Mercury Vapor Lighting 250 Watt High Pressure Sodium Lighting 250 Watt Mercury Vapor Lighting 400 Watt Mercury Vapor Lighting 400 Watt Metal Halide Lighting

109

Programming Language Concepts and Paradigms David A Watt 6-1 Solutions to Exercises 6  

E-Print Network (OSTI)

Programming Language Concepts and Paradigms © David A Watt 6-1 Solutions to Exercises 6 6;Programming Language Concepts and Paradigms © David A Watt 6-2 6.2.3 Date abstract type in ADA: (a) Possible and Paradigms © David A Watt 6-3 function "+" (r1, r2: Rat) return Rat is begin return (r1.num*r2.den + r2.num

Watt, David A.

110

Absolute Factorization of Bivariate Polynomials with Floating Point Coe cients Andr Galligo and Stephen M. Watt  

E-Print Network (OSTI)

and Stephen M. Watt University of Nice-Sophia Antipolis Given a polynomial px y of degree d and complex oating

Watt, Stephen M.

111

Some Comments on James Watt's Published Account of His Work on Steam and Steam Engines  

Science Journals Connector (OSTI)

1 June 1971 research-article Some Comments on James Watt's Published Account of His Work on Steam and Steam Engines W. A. Smeaton

1971-01-01T23:59:59.000Z

112

ORNL Trusted Corridors Project: Watts Bar Dam Inland Waterway Project  

SciTech Connect

Radiation has existed everywhere in the environment since the Earth's formation - in rocks, soil, water, and plants. The mining and processing of naturally occurring radioactive materials for use in medicine, power generation, consumer products, and industry inevitably generate emissions and waste. Radiological measuring devices have been used by industry for years to measure for radiation in undesired locations or simply identify radioactive materials. Since the terrorist attacks on the United States on 9-11-01 these radiation measuring devices have proliferated in many places in our nation's commerce system. DOE, TVA, the Army Corps and ORNL collaborated to test the usefulness of these devices in our nation's waterway system on this project. The purpose of the Watts Bar Dam ORNL Trusted Corridors project was to investigate the security, safety and enforcement needs of local, state and federal government entities for state-of-the-art sensor monitoring in regards to illegal cargo including utilization of the existing infrastructure. TVA's inland waterways lock system is a recognized and accepted infrastructure by the commercial carrier industry. Safety Monitoring activities included tow boat operators, commercial barges and vessels, recreational watercraft and their cargo, identification of unsafe vessels and carriers, and, monitoring of domestic and foreign commercial vessels and cargo identification. Safety Enforcement activities included cargo safety, tracking, identification of hazardous materials, waterway safety regulations, and hazardous materials regulations. Homeland Security and Law Enforcement Applications included Radiological Dispersive Devices (RDD) identification, identification of unsafe or illicit transport of hazardous materials including chemicals and radiological materials, and screening for shipments of illicit drugs. In the Fall of 2005 the SensorNet funding for the project expired. After several unsuccessful attempts to find a Federal sponsor to continue with the project, the Watts Bar Dam Project was canceled and the Exploranium radiation monitors were removed from the doors of Watts Bar Dam in early 2006. The DHS Domestic Nuclear Detection Office decided to proceed with a Pilot building on the ORNL work performed at the TN and SC weigh stations in the highway sector of the Trusted Corridors project and eventually expanded it to other southern states under the name of Southeastern Corridor Pilot Project (SETCP). Many of the Phase I goals were achieved however real-world test data of private watercraft and barges was never obtained.

Walker, Randy M [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Hill, David E [ORNL

2011-11-01T23:59:59.000Z

113

Calibrated vapor generator source  

DOE Patents (OSTI)

A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.

Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.

1995-09-26T23:59:59.000Z

114

Further testing and development of an 11-watt Stirling converter  

SciTech Connect

Three previous IECEC papers describe the development of an 11-watt Radioisotope Stirling Generator (RSG) intended for remote power applications. This paper describes more recent testing and development activities. Testing of the engineering model (EM) was performed to determine the effect of heat rejection temperature, thermal input and initial charge pressure on thermal efficiency. Shock testing of the generator included a drop test and 3 hours of testing in a random vibration environment where g{sup 2}/Hz = 0.04. Endurance testing of a complete Stirling converter continues, with over 15,000 maintenance-free operating hours. Endurance testing of critical subsystems and components has achieved 14,000 to 26,000 hours of operation without failure. Minor changes to the RSG prototype design, based on the development of the EM, are described.

Ross, B.A.; Montgomery, W.L. [Stirling Technology Co., Richland, WA (United States)

1995-12-31T23:59:59.000Z

115

Programming Language Concepts and Paradigms David A Watt 5-1 Solutions to Exercises 5  

E-Print Network (OSTI)

Programming Language Concepts and Paradigms © David A Watt 5-1 Solutions to Exercises 5 5.1.1 We;Programming Language Concepts and Paradigms © David A Watt 5-2 · Reference parameter mechanisms: v, w, and sum

Watt, David A.

116

New Aspects of InkML for Pen-Based Computing Stephen M. Watt  

E-Print Network (OSTI)

New Aspects of InkML for Pen-Based Computing Stephen M. Watt Department of Computer Science University of Western Ontario London, Ontario, Canada N6A 5B7 watt@csd.uwo.ca Abstract As pen-based computing

Watt, Stephen M.

117

Programming Language Concepts and Paradigms David A Watt 4-1 Solutions to Exercises 4  

E-Print Network (OSTI)

Programming Language Concepts and Paradigms © David A Watt 4-1 Solutions to Exercises 4 4 with a Nat in-parameter } #12;Programming Language Concepts and Paradigms © David A Watt 4-2 4.2.2 Static vs

Watt, David A.

118

Approximate Polynomial Decomposition Robert M. Corless Mark W. Giesbrecht David J. Jeffrey Stephen M. Watt  

E-Print Network (OSTI)

M. Watt Dept. of Computer Science and Dept. of Applied Mathematics University of Western Ontario London, ON, N6A 5B7, Canada email: Rob.Corless, Mark.Giesbrecht David.Jeffrey, Stephen.Watt @uwo.ca 1

Watt, Stephen M.

119

CS 115: Programming I Spring 2014 Instructors Dr. Suzanne Rivoire, Dr. Tia Watts, Noah Melcon  

E-Print Network (OSTI)

CS 115: Programming I ­ Spring 2014 Instructors Dr. Suzanne Rivoire, Dr. Tia Watts, Noah Melcon Meeting times Lecture: TTh 9:20­10:35 Darwin 102 Rivoire Lab (Sections 1/2): T 5:00­7:50 Darwin 25 Watts

Ravikumar, B.

120

Free-hand Sketch Grouping for Video Retrieval J. P. Collomosse, G. McNeill, and L. Watts  

E-Print Network (OSTI)

Free-hand Sketch Grouping for Video Retrieval J. P. Collomosse, G. McNeill, and L. Watts Department of Computer Science, University of Bath, UK {jpc, g.mcneill, l.watts}@cs.bath.ac.uk Abstract We present

Collomosse, John

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

*s.watt@bangor.ac.uk Achieving near-correct focus cues in a 3-D display using multiple  

E-Print Network (OSTI)

*s.watt@bangor.ac.uk Achieving near-correct focus cues in a 3-D display using multiple image planes Simon J. Watt* a , Kurt Akeley b , Ahna R. Girshick c , Martin S. Banks c a School of Psychology

Banks, Marty

122

ARM Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

ARM Water Vapor IOP The SGP CART site will host the third ARM water vapor IOP on September 18-October 8, 2000. The CART site is home to a powerful array of instruments capable of...

123

Utilizing RF-I and Intelligent Scheduling for Better Throughput/Watt in a Mobile GPU Memory System  

E-Print Network (OSTI)

Utilizing RF-I and Intelligent Scheduling for Better Throughput/Watt in a Mobile GPU Memory System system is essential for the mobile GPU. In this article, we propose to improve throughput/watt are able to improve throughput 17% up to 66% while increasing throughput per watt by an average of 18% up

Cong, Jason "Jingsheng"

124

Recycling of sodium waste  

Science Journals Connector (OSTI)

Recycling of sodium waste ... Methods for handling and recycling a dangerous and costly chemical. ...

Bettina Hubler-Blank; Michael Witt; Herbert W. Roesky

1993-01-01T23:59:59.000Z

125

Third generation development of an 11-watt Stirling converter  

SciTech Connect

This paper describes recent design enhancements, performance results, and development of an artificial neural network (ANN) model related to the Radioisotope Stirling Generator (RSG), an 11-watt converter designed for remote power applications. Design enhancements include minor changes to improve performance, increase reliability, facilitate fabrication and assembly for limited production, and reduce mass. Innovative modifications were effected to increase performance and improve reliability of the vacuum foil insulation (VFI) package and linear alternator. High and low operating temperature acceptance testing of the Engineering Model (EM) demonstrated the robust system characteristics. These tests were conducted for 1 week of operation each, with rejector temperatures of 95 C and 20 C, respectively. Endurance testing continues for a complete Stirling converter, the Development Model (DM), with over 25,000 hours of maintenance-free operation. Endurance testing of flexures has attained over 540 flexure-years and endurance testing of linear motors/alternators has achieved nearly 27,000 hours of operation without failure. An ANN model was developed and tested successfully on the DM. Rejection temperatures were varied between 3 C and 75 C while load voltages ranged between engine stall and displacer overstroke. The trained ANN model, based solely on externally measured parameters, predicted values of piston amplitude, displacer amplitude, and piston-displacer phase angle within {+-}2% of the measured values over the entire operating regime. The ANN model demonstrated its effectiveness in the long-term evaluation of free-piston Stirling machines without adding the complexity, reduced reliability, and increased cost of sophisticated diagnostic instrumentation.

Montgomery, W.L.; Ross, B.A.; Penswick, L.B. [Stirling Technology Co., Kennewick, WA (United States)

1996-12-31T23:59:59.000Z

126

A guide to web content for Heriot-Watt University websites  

E-Print Network (OSTI)

1 A guide to web content for Heriot-Watt University websites #12;2 Contents A guide to web content..........................................................................................................................3 Why is writing for the web different?..........................................................................................3 Planning your web content

Howie, Jim

127

WATTS TOWERS: THE EFFECTS OF THERMAL CYCLES ON THE FORMATION AND BEHAVIOR OF CRACKS  

E-Print Network (OSTI)

to make lasting repairs to the Watts Towers. 15 REFERENCES [1] LSTC. "LS-DYNA KEYWROD MANUAL." DYNA Support. Livermore Software Technology Corporation, n.d. Web. 5 Apr. 2013.

Spencer, Matthew T

2013-02-06T23:59:59.000Z

128

Solar-induced chemical vapor deposition of diamond-type carbon films  

DOE Patents (OSTI)

An improved chemical vapor deposition method for depositing transparent continuous coatings of sp[sup 3]-bonded diamond-type carbon films, comprises: (a) providing a volatile hydrocarbon gas/H[sub 2] reactant mixture in a cold wall vacuum/chemical vapor deposition chamber containing a suitable substrate for said films, at pressure of about 1 to 50 Torr; and (b) directing a concentrated solar flux of from about 40 to about 60 watts/cm[sup 2] through said reactant mixture to produce substrate temperatures of about 750 C to about 950 C to activate deposition of the film on said substrate. 11 figs.

Pitts, J.R.; Tracy, C.E.; King, D.E.; Stanley, J.T.

1994-09-13T23:59:59.000Z

129

Solar-induced chemical vapor deposition of diamond-type carbon films  

DOE Patents (OSTI)

An improved chemical vapor deposition method for depositing transparent continuous coatings of sp.sup.3 -bonded diamond-type carbon films, comprising: a) providing a volatile hydrocarbon gas/H.sub.2 reactant mixture in a cold wall vacuum/chemical vapor deposition chamber containing a suitable substrate for said films, at pressure of about 1 to 50 Torr; and b) directing a concentrated solar flux of from about 40 to about 60 watts/cm.sup.2 through said reactant mixture to produce substrate temperatures of about 750.degree. C. to about 950.degree. C. to activate deposition of the film on said substrate.

Pitts, J. Roland (Lakewood, CO); Tracy, C. Edwin (Golden, CO); King, David E. (Lakewood, CO); Stanley, James T. (Beaverton, OR)

1994-01-01T23:59:59.000Z

130

City of Frankfort, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Frankfort Frankfort Place Indiana Utility Id 6707 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png A Residential Residential B Commercial Commercial C General Power Economic Development Rate OL Outdoor Lighting 100 watt Sodium Vapor Lighting OL Outdoor Lighting 150 watt Sodium Vapor Lighting OL Outdoor Lighting 175 watt Mercury Vapor Lighting OL Outdoor Lighting 250 watt Mercury Vapor Lighting OL Outdoor Lighting 250 watt Sodium Vapor Lighting OL Outdoor Lighting 400 watt Mercury Vapor Lighting

131

Vapor spill monitoring method  

DOE Patents (OSTI)

Method for continuous sampling of liquified natural gas effluent from a spill pipe, vaporizing the cold liquified natural gas, and feeding the vaporized gas into an infrared detector to measure the gas composition. The apparatus utilizes a probe having an inner channel for receiving samples of liquified natural gas and a surrounding water jacket through which warm water is flowed to flash vaporize the liquified natural gas.

Bianchini, Gregory M. (Livermore, CA); McRae, Thomas G. (Livermore, CA)

1985-01-01T23:59:59.000Z

132

Structural Studies on the Hydration of L-Glutamic Acid in Solution Sylvia E. McLain,*,, Alan K. Soper, and Anthony Watts,  

E-Print Network (OSTI)

. Soper, and Anthony Watts, Rutherford Appleton Laboratory, ISIS Facility, Chilton, Didcot, Oxfordshire OX

Watts, Anthony

133

Structure and Hydration of L-Proline in Aqueous Solutions Sylvia E. McLain,*,, Alan K. Soper, Ann E. Terry, and Anthony Watts  

E-Print Network (OSTI)

. Terry, and Anthony Watts ISIS Facility, Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire OX

Watts, Anthony

134

ARM - Water Vapor  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Vapor Outreach Home Room News Publications Traditional Knowledge Kiosks Barrow, Alaska Tropical Western Pacific Site Tours Contacts Students Study Hall About ARM Global...

135

Dalton Utilities | Open Energy Information  

Open Energy Info (EERE)

Dalton Utilities Dalton Utilities Jump to: navigation, search Name Dalton Utilities Place Georgia Utility Id 4744 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 - Watt Sodium Vapor Lighting 1000 - Watt Metal Halide Directional Type Lighting 150 Watt Mercury Vapor Underground Service Lighting 150 Watt Sodium Vapor Underground Service Lighting 175 - Watt Mercury Vapor Lighting 175 - Watt Sodium Vapor Lighting

136

City of Emerson, Nebraska (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Emerson, Nebraska (Utility Company) Emerson, Nebraska (Utility Company) Jump to: navigation, search Name City of Emerson Place Nebraska Utility Id 5850 Utility Location Yes Ownership M NERC Location MRO Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 watt High Pressure Sodium Lighting 150 watt High Pressure Sodium Lighting 175 watt Mercury Vapor Lighting 250 watt High Pressure Sodium Lighting 250 watt High Pressure Sodium Flood Lighting 250 watt Mercury Vapor Lighting 400 watt High Pressure Sodium Flood Lighting

137

The Kill-a-Watt Competition at University of Central Florida | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Kill-a-Watt Competition at University of Central Florida The Kill-a-Watt Competition at University of Central Florida The Kill-a-Watt Competition at University of Central Florida Addthis Description At the University of Central Florida, students have taken it upon themselves to create a culture of energy efficiency. Each year, different dorm buildings compete to see who can save the most. In 2009, the school saw a total savings of $27,000. As of March 2010, they've saved over $24,000 this year alone. Speakers Chris Castro, Alexandra Kennedy, Margaret Lo, David Norvell, Keith Coelho, John Hitt PhD Duration 5:40 Topic Energy Efficiency Commercial Heating & Cooling Consumption Credit Energy Department Video CHRIS CASTRO: Last summer, I was an intern at the Department of Energy Office of Energy Efficiency and Renewable Energy and I got a chance to

138

Watch the Watts: Tips for Buying a New Television | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Watch the Watts: Tips for Buying a New Television Watch the Watts: Tips for Buying a New Television Watch the Watts: Tips for Buying a New Television March 8, 2011 - 6:30am Addthis Jeannie Saur Senior Communicator, National Renewable Energy Laboratory Buying a new television in a complex and feature-rich market can be a daunting experience. Sure there are lots of great choices with stunning picture quality and amazing features. And with so much competition, TV prices have fallen dramatically from even a year ago. But when my 1990-era television finally died, I was overwhelmed with choices for a flat screen TV. There are plasmas, liquid crystal displays (LCDs), and light-emitting diodes (LEDs). TVs can be Internet enabled so they can stream programming. And now there are a number of choices for 3D viewing. With so many things to consider, I decided the most important

139

MULTI-WATT ELECTRIC POWER FROM A MICROFABRICATED PERMANENT-MAGNET GENERATOR  

E-Print Network (OSTI)

MULTI-WATT ELECTRIC POWER FROM A MICROFABRICATED PERMANENT-MAGNET GENERATOR S. Das1 , D. P. Arnold2 presents the design, fabrication, and characterization of permanent-magnet (PM) generators for use, coupled to a transformer and rectifier, delivers 1.1 W of DC electrical power to a resistive load

140

HMM adaptation and voice conversion for the synthesis of child speech: a Oliver Watts1  

E-Print Network (OSTI)

, Junichi Yamagishi1 , Simon King1 , Kay Berkling2 1 Centre for Speech Technology Research, University of Edinburgh, UK 2 Inline Internet Online Dienste GmbH, Germany O.S.Watts@sms.ed.ac.uk jyamagis- netically balanced, consistently read, and cleanly recorded. The type of child speech typically available

Edinburgh, University of

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

La question du privilge en France pour la machine de Watt Paul Naegel,  

E-Print Network (OSTI)

;2 The steam engine, invented and patented in 1769 by James Watt, then marketed by him in association of very large diameter. Started in England, matters related to the new steam engines were obtained opportunities were based in France on already known applications, made with Newcomen fire engines

Paris-Sud XI, Université de

142

Sub-100 fs pulses at watt-level powers from a dissipative-soliton fiber laser  

E-Print Network (OSTI)

with cladding pumping for high average power. The laser generates 31 nJ chirped pulses at 70 MHz repetition rate of double-clad (DC) gain fiber is common, and there are a few reports of mode-locked lasers that employ DCSub-100 fs pulses at watt-level powers from a dissipative-soliton fiber laser K. Kieu,* W. H

Kieu, Khanh

143

University of Hawai`i Watt Watcher: Energy Consumption Data Analysis  

E-Print Network (OSTI)

: This material is based upon work supported by the United States Department of Energy under Award Number DE-FC-06 or reflect those of the United States Government or any agency thereof. #12; UH Watt Watcher: Energy A METHODS Background 18 Energy Use Measurement 19 Comfort Level Measurement

144

Statistical analysis of wind energy in Chile David Watts a,b,*, Danilo Jara a  

E-Print Network (OSTI)

Data Bank Statistical analysis of wind energy in Chile David Watts a,b,*, Danilo Jara December 2010 Keywords: Wind Wind speed Energy Capacity factor Electricity Chile a b s t r a c t Bearing role in any future national energy generation matrix. With a view to understanding the local wind

Catholic University of Chile (Universidad Católica de Chile)

145

A 5-WATT, 37-GHz MONOLITHIC GRID AMPLIFIER Blythe Deckman1  

E-Print Network (OSTI)

of the fabricated active grid. Thermal Management Previous grid amplifiers lacked a heat spreader, so Figure 1A 5-WATT, 37-GHz MONOLITHIC GRID AMPLIFIER Blythe Deckman1 , Donald S. Deakin, Jr.2 , Emilio Sovero has been demonstrated. The area of the grid am- plifier is 1 cm2, and there are 512 transistors

146

Rigid Deployable Solar Array A.M. Watt and S. Pellegrino  

E-Print Network (OSTI)

with the design of low-cost rigid-panel deployable solar arrays with self- locking tape-spring hinges. The reportRigid Deployable Solar Array A.M. Watt and S. Pellegrino CUED/D-STRUCT/TR214 Department on the deployment of a solar array wing are evaluated experimentally. #12;#12;Contents 1 Introduction 1 1.1 Layout

Pellegrino, Sergio

147

Gasoline vapor recovery  

SciTech Connect

In a gasoline distribution network wherein gasoline is drawn from a gasoline storage tank and pumped into individual vehicles and wherein the gasoline storage tank is refilled periodically from a gasoline tanker truck, a method of recovering liquid gasoline from gasoline vapor that collects in the headspace of the gasoline storage tank as the liquid gasoline is drawn therefrom, said method comprising the steps of: (a) providing a source of inert gas; (b) introducing inert gas into the gasoline storage tank as liquid gasoline is drawn therefrom so that liquid gasoline drawn from the tank is displaced by inert gas and gasoline vapor mixes with the inert gas in the headspace of the tank; (c) collecting the inert gas/gasoline vapor mixture from the headspace of the gasoline storage tank as the tank is refilled from a gasoline tanker truck; (d) cooling the inert gas/gasoline vapor mixture to a temperature sufficient to condense the gasoline vapor in the mixture to liquid gasoline but not sufficient to liquify the inert gas in the mixture; (e) separating the condensed liquid gasoline from the inert gas; and delivering the condensed liquid gasoline to a remote location for subsequent use.

Lievens, G.; Tiberi, T.P.

1993-06-22T23:59:59.000Z

148

Distributed Models of Thread-Level Speculation Cosmin E. Oancea, Jason W. A. Selby, Mark W. Giesbrecht and Stephen M. Watt  

E-Print Network (OSTI)

. Giesbrecht and Stephen M. Watt Department of Computer Science, University of Western Ontario, London, Ontario, Canada, N6A 5B7 coancea,watt@csd.uwo.ca School of Computer Science, University of Waterloo

Giesbrecht, Mark

149

Federated Authentication & Authorisation for e-Science J. Watt, R.O. Sinnott, J. Jiang, T. Doherty, A.J. Stell, D. Martin, G. Stewart  

E-Print Network (OSTI)

Federated Authentication & Authorisation for e-Science J. Watt, R.O. Sinnott, J. Jiang, T. Doherty, UK j.watt@nesc.gla.ac.uk Abstract The Grid and Web service community are defining a range of stan

Glasgow, University of

150

Sodium removal process development for LMFBR fuel subassemblies  

SciTech Connect

Two 37-pin scale models of Clinch River Breeder Reactor Plant fuel subassemblies were designed, fabricated and used at Westinghouse Advanced Reactors Division in the development and proof-testing of a rapid water-based sodium removal process for the ORNL Hot Experimental Facility, Liquid Metal Fast Breeder Reactor Fuel Reprocessing Cycle. Through a series of development tests on one of the models, including five (5) sodium wettings and three (3) high temperature sodium removal operations, optimum process parameters for a rapid water vapor-argon-water rinse process were identified and successfully proof-tested on a second model containing argon-pressurized, sodium-corroded model fuel pins simulating the gas plenum and cladding conditions expected for spent fuel pins in full scale subassemblies. Based on extrapolations of model proof test data, preliminary process parameters for a water vapor-nitrogen-water rinse process were calculated and recommended for use in processing full scale fuel subassemblies in the Sodium Removal Facility of the Fuel Receiving Cell, ORNL HEF.

Simmons, C.R.; Taylor, G.R.

1981-10-01T23:59:59.000Z

151

City of Lebanon, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Indiana Indiana Utility Id 9613 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png CS - Electric Commercial Polyphase Commercial CS - Electric Commercial Single Phase Commercial MS - Electric Municipal OL - Outdoor Lighting 100 watt sodium vapor Lighting OL - Outdoor Lighting 150 watt sodium vapor Lighting OL - Outdoor Lighting 175 watt mercury vapor Lighting OL - Outdoor Lighting 200 watt sodium vapor Lighting OL - Outdoor Lighting 250 watt mercury vapor Lighting

152

Electrolyte vapor condenser  

DOE Patents (OSTI)

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well. 3 figs.

Sederquist, R.A.; Szydlowski, D.F.; Sawyer, R.D.

1983-02-08T23:59:59.000Z

153

Electrolyte vapor condenser  

DOE Patents (OSTI)

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well.

Sederquist, Richard A. (Newington, CT); Szydlowski, Donald F. (East Hartford, CT); Sawyer, Richard D. (Canton, CT)

1983-01-01T23:59:59.000Z

154

The Model 5000-16C 1000 WATT FEL Lamp Standard pro-vides absolute calibration of spectral irradiance from 250 nm to  

E-Print Network (OSTI)

The Model 5000-16C 1000 WATT FEL Lamp Standard pro- vides absolute calibration of spectral. It has been selected by the National Institute of Standards and Technology to replace the 1000 watt, DXW-pin 1000 watt lamp that is adapted by Gamma Scientific into a bi-post configuration. It is used

155

Wildlife Management: The Case of Bucks Only Hunting The model in Figure 1 is adapted from an example in Ken Watt's (1968) text on Ecology and  

E-Print Network (OSTI)

an example in Ken Watt's (1968) text on Ecology and Resource Management. It distinguishes between bucks that this population will grow, despite the aggressive hunting of the adult bucks. This diagram is adapted from Watt's description of a theoretical deer herd (Watt 1968, p. 127). He uses the numerical example to argue against

Ford, Andrew

156

Submersible sodium pump  

DOE Patents (OSTI)

An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates. 14 figs.

Brynsvold, G.V.; Lopez, J.T.; Olich, E.E.; West, C.W.

1989-11-21T23:59:59.000Z

157

Optimizing performance per watt on GPUs in High Performance Computing: temperature, frequency and voltage effects  

E-Print Network (OSTI)

The magnitude of the real-time digital signal processing challenge attached to large radio astronomical antenna arrays motivates use of high performance computing (HPC) systems. The need for high power efficiency (performance per watt) at remote observatory sites parallels that in HPC broadly, where efficiency is an emerging critical metric. We investigate how the performance per watt of graphics processing units (GPUs) is affected by temperature, core clock frequency and voltage. Our results highlight how the underlying physical processes that govern transistor operation affect power efficiency. In particular, we show experimentally that GPU power consumption grows non-linearly with both temperature and supply voltage, as predicted by physical transistor models. We show lowering GPU supply voltage and increasing clock frequency while maintaining a low die temperature increases the power efficiency of an NVIDIA K20 GPU by up to 37-48% over default settings when running xGPU, a compute-bound code used in radio...

Price, D C; Barsdell, B R; Babich, R; Greenhill, L J

2014-01-01T23:59:59.000Z

158

Organic vapor jet printing system  

SciTech Connect

An organic vapor jet printing system includes a pump for increasing the pressure of an organic flux.

Forrest, Stephen R

2012-10-23T23:59:59.000Z

159

Zinc and cadmium residues in striped bass from Cherokee, Norris, and Watts Bar reservoirs  

SciTech Connect

Zinc and cadmium concentrations in muscle, liver, and kidney were measured in striped bass (Morone saxatilis) from Cherokee, Norris, and Watts Bar reservoirs in East Tennessee to determine if these metals had contributed to fish kills observed in Cherokee during the 1970's. The range of mean concentrations of zinc from collections of Cherokee striped bass (muscle 11-14, liver 98-106, kidney 88-105 mg Zn/kg dry weight) were comparable to ranges in fish from Norris and Watts Bar (muscle 12-13, liver 83-132, kidney 96-108 mg/kg dry weight). With the exception of concentrations in the kidneys of one collection, cadmium residues from Cherokee striped bass (muscle 0.02-0.09, liver 0.3-0.7, kidney 0.2-4.0 mg Cd/kg dry weight) were also similar to residues from Norris and Watts Bar fish (muscle 0.05-0.13, liver 0.3-2.1, kidney 0.3-0.5 mg Cd/kg dry weight). There were significant differences in tissue residues among seasons (summer 1979, spring 1980, summer 1980) in Cherokee Reservoir, as well as significant differences among the three reservoirs (Cherokee, Norris, Watts Bar) during the same season (spring 1980). All concentrations, however, were well below those reported for fish exposed to the maximum non-harmful concentrations of zinc and the lowest potentially harmful concentration of cadmium and moreover, were within the range typically reported for fish tissues. It is, therefore, believed that in at least the last two years, zinc and cadmium in the tissues of striped bass from Cherokee Reservoir have not been harmful to the fish.

Tisa, M.S.; Strange, R.J.

1981-10-01T23:59:59.000Z

160

Hickman-Fulton Counties RECC | Open Energy Information  

Open Energy Info (EERE)

Hickman-Fulton Counties RECC Hickman-Fulton Counties RECC Jump to: navigation, search Name Hickman-Fulton Counties RECC Place Kentucky Utility Id 40305 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Lighting 100 Watt Metal Halide Light Lighting 175 Watt Mercury Vapor Light Lighting 175 Watt Metal Halide Light Lighting 200 Watt High Pressure Sodium Lighting 400 Watt High Pressure Sodium Lighting 400 Watt Mercury Vapor Light Lighting GSA Part 1 Commercial GSA Part 2 Industrial

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Acoustic Emission Monitoring of ASME Section III Hydrostatic Test: Watts Bar Unit 1 Nuclear Reactor  

SciTech Connect

Through the cooperation of the Tennessee Valley Authority, Pacific Northwest Laboratory has installed instrumentation on Watts Bar Nuclear Power Plant Unit 1 for the purpose of test and evaluation of acoustic emission (AE) monitoring of nuclear reactor pressure vessels and piping for flaw detection. This report describes the acoustic emission monitoring performed during the ASME Section III hydrostatic testing of Watts Bar Nuclear Power Plant Unit 1 and the results obtained. Highlights of the results are: Spontaneous AE was detected from a nozzle area during final pressurization. Evaluation of the apparent source of the spontaneous AE using an empirically derived AE/fracture mechanics relationship agreed within a factor of two with an evaluation by ASME Section XI Code procedures. AE was detected from a fracture specimen which was pressure coupled to the 10-inch accumulator nozzle. This provided reassurance of adequate system sensitivity. High background noise was observed when all four reactor coolant pumps were operating. Work is continuing at Watts Bar Unit 1 toward AE monitoring hot functional testing and subsequently monitoring during reactor operation.

Hutton,, P. H.; Taylor,, T. T.; Dawson,, J. F.; Pappas,, R. A.; Kurtz,, R. J.

1982-06-01T23:59:59.000Z

162

Parametric design study of ``mini-generator`` with 6-watt heat source  

SciTech Connect

The Fairchild study showed that generator designs based on a single 1-watt RHU had very poor thermal efficiencies. At their optimum operating point, more than half of the generated heat was lost through the thermal insulation. This resulted in system efficiency of only 2.2%, compared to 7.2% for current Radioisotope Thermoelectric Generators (RTGs). Moreover, there were serious doubts about the fabricability of the required multicouples, particularly of the series/parallel connections between the large number (900) of thermoelectric legs of very small cross-section (0.21 mm square). All in all, the preceding paper showed that neither JPL`s Power Stick design nor the Fairchild-generated derivatives based on the 1-watt heat source looked promising. The present paper describes a similar parametric study of a mini-generator based on a 6-watt heat source, and compares its performance and fabricability to that of the optimum Power Stick derivative and of the current RTG design for the same mission. {copyright} 1995 {ital American} {ital Institute} {ital of} {ital Physics}

Schock, A.; Or, C.T. [Orbital Sciences Corporation, 20301 Century Blvd., Germantown, Maryland 20874 (United States)

1995-01-20T23:59:59.000Z

163

Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor Mercury Vapor Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Mercury Vapor Details Activities (23) Areas (23) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Fluid Lab Analysis Parent Exploration Technique: Fluid Lab Analysis Information Provided by Technique Lithology: Stratigraphic/Structural: Anomalously high concentrations can indicate high permeability or conduit for fluid flow Hydrological: Field wide soil sampling can generate a geometrical approximation of fluid circulation Thermal: High concentration in soils can be indicative of active hydrothermal activity Dictionary.png Mercury Vapor: Mercury is discharged as a highly volatile vapor during hydrothermal

164

Stratified vapor generator  

DOE Patents (OSTI)

A stratified vapor generator (110) comprises a first heating section (H.sub.1) and a second heating section (H.sub.2). The first and second heating sections (H.sub.1, H.sub.2) are arranged so that the inlet of the second heating section (H.sub.2) is operatively associated with the outlet of the first heating section (H.sub.1). A moisture separator (126) having a vapor outlet (164) and a liquid outlet (144) is operatively associated with the outlet (124) of the second heating section (H.sub.2). A cooling section (C.sub.1) is operatively associated with the liquid outlet (144) of the moisture separator (126) and includes an outlet that is operatively associated with the inlet of the second heating section (H.sub.2).

Bharathan, Desikan (Lakewood, CO); Hassani, Vahab (Golden, CO)

2008-05-20T23:59:59.000Z

166

Vapor Barriers or Vapor Diffusion Retarders | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Home Air Sealing for New Home Construction Insulation Types of Insulation Insulation and Air Sealing Products and Services External Resources Find a Local AirVapor Barrier...

167

Acoustic emission monitoring of hot functional testing: Watts Bar Unit 1 Nuclear Reactor  

SciTech Connect

Acoustic emission (AE) monitoring of selected pressure boundary areas at TVA's Watts Bar, Unit 1 Nuclear Power Plant during hot functional preservice testing is described in this report. The report deals with background, methodology, and results. The work discussed here is a major milestone in a program supported by NRC to develop and demonstrate application of AE monitoring for continuous surveillance of reactor pressure boundaries to detect and evaluate growing flaws. The subject work demonstrated that anticipated problem areas can be overcome. Work is continuing toward AE monitoring during reactor operation.

Hutton, P.H.; Dawson, J.F.; Friesel, M.A.; Harris, J.C.; Pappas, R.A.

1984-06-01T23:59:59.000Z

168

Vapor spill pipe monitor  

DOE Patents (OSTI)

The invention is a method and apparatus for continually monitoring the composition of liquefied natural gas flowing from a spill pipe during a spill test by continually removing a sample of the LNG by means of a probe, gasifying the LNG in the probe, and sending the vaporized LNG to a remote ir gas detector for analysis. The probe comprises three spaced concentric tubes surrounded by a water jacket which communicates with a flow channel defined between the inner and middle, and middle and outer tubes. The inner tube is connected to a pump for providing suction, and the probe is positioned in the LNG flow below the spill pipe with the tip oriented partly downward so that LNG is continuously drawn into the inner tube through a small orifice. The probe is made of a high thermal conductivity metal. Hot water is flowed through the water jacket and through the flow channel between the three tubes to provide the necessary heat transfer to flash vaporize the LNG passing through the inner channel of the probe. The gasified LNG is transported through a connected hose or tubing extending from the probe to a remote ir sensor which measures the gas composition.

Bianchini, G.M.; McRae, T.G.

1983-06-23T23:59:59.000Z

169

Williamstown Utility Comm | Open Energy Information  

Open Energy Info (EERE)

Williamstown Utility Comm Williamstown Utility Comm Jump to: navigation, search Name Williamstown Utility Comm Place Kentucky Utility Id 20731 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Area Light Lighting 150 Watt High Pressure Sodium Floodlight Lighting 175 Watt Mercury Vapor Area Light Lighting 250 Watt High Pressure Sodium Area Light Lighting 250 Watt High Pressure Sodium Floodlight Lighting 400 Watt High Pressure Sodium Area Light Lighting

170

Terrebonne Parish Consol Gov't | Open Energy Information  

Open Energy Info (EERE)

Terrebonne Parish Consol Gov't Terrebonne Parish Consol Gov't Jump to: navigation, search Name Terrebonne Parish Consol Gov't Place Louisiana Utility Id 8884 Utility Location Yes Ownership M NERC Location SPP NERC SPP Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Vapor Light Lighting 250 Watt High Pressure Sodium Vapor Light Cobra Head Lighting 400 Watt High Pressure Sodium Vapor Flood Light Lighting 400 Watt High Pressure Sodium Vapor Light Cobra Head Lighting

171

A FIVE-WATTS G-M/J-T REFRIGERATOR FOR LHE TARGET AT BNL.  

SciTech Connect

A five-watts G-M/J-T refrigerator was built and installed for the high-energy physics research at Brookhaven National Laboratory in 2001. A liquid helium target of 8.25 liters was required for an experiment in the proton beam line at the Alternating Gradient Synchrotron (AGS) of BNL. The large radiation heat load towards the target requires a five-watts refrigerator at 4.2 K to support a liquid helium flask of 0.2 meter in diameter and 0.3 meter in length which is made of Mylar film of 0.35 mm in thickness. The liquid helium flask is thermally exposed to the vacuum windows that are also made of 0.35 mm thickness Mylar film at room temperature. The refrigerator uses a two-stage Gifford-McMahon cryocooler for precooling the Joule-Thomson circuit that consists of five Linde-type heat exchangers. A mass flow rate of 0.8 {approx} 1.0 grams per second at 17.7 atm is applied to the refrigerator cold box. The two-phase helium flows between the liquid target and liquid/gas separator by means of thermosyphon. The paper presents the system design as well as the test results including the control of thermal oscillation.

JIA,L.X.; WANG,L.; ADDESSI,L.; MIGLIONICO,G.; MARTIN,D.; LESKOWICZ,J.; MCNEILL,M.; YATAURO,B.; TALLERICO,T.

2001-07-16T23:59:59.000Z

172

Java Collections 2001 D.A. Watt and D.F. Brown 6-1 Solutions to Exercises in Chapter 6  

E-Print Network (OSTI)

Java Collections © 2001 D.A. Watt and D.F. Brown 6-1 Solutions to Exercises in Chapter 6 6 from input to output, using spur: #12;Java Collections © 2001 D.A. Watt and D.F. Brown 6-2 1. For c = 1 `[' 2 depth=3 4 5After scanning `arg[': #12;Java Collections © 2001 D.A. Watt and D.F. Brown 6-3 Figure

Watt, David A.

173

Java Collections 2001 D.A. Watt and D.F. Brown 2-1 Solutions to Exercises in Chapter 2  

E-Print Network (OSTI)

Java Collections © 2001 D.A. Watt and D.F. Brown 2-1 Solutions to Exercises in Chapter 2 2 (non-recursive version): #12;Java Collections © 2001 D.A. Watt and D.F. Brown 2-2 static int factorial of program: #12;Java Collections © 2001 D.A. Watt and D.F. Brown 2-3 static void moveTower (int n, int source

Watt, David A.

174

Java Collections 2001 D.A. Watt and D.F. Brown 10-1 Solutions to Exercises in Chapter 10  

E-Print Network (OSTI)

Java Collections © 2001 D.A. Watt and D.F. Brown 10-1 Solutions to Exercises in Chapter 10 10 the subtree whose topmost node is top (recursive version): #12;Java Collections © 2001 D.A. Watt and D.max(depth(top.left), depth(top.right)); } #12;Java Collections © 2001 D.A. Watt and D.F. Brown 10-3 public static Object get

Watt, David A.

175

Java Collections 2001 D.A. Watt and D.F. Brown 13-1 Solutions to Exercises in Chapter 13  

E-Print Network (OSTI)

Java Collections © 2001 D.A. Watt and D.F. Brown 13-1 Solutions to Exercises in Chapter 13 13 E G A B C D E GF A D G D G D #12;Java Collections © 2001 D.A. Watt and D.F. Brown 13-2 Figure S13 Collections © 2001 D.A. Watt and D.F. Brown 13-3 public class UnsortedLinkedPriorityQueue implements Priority

Watt, David A.

176

P26W-5 eCo iPs P24W-5 eCo iPs special features In Plane Switching (IPS), 0 Watt  

E-Print Network (OSTI)

Watt in power save mode, ECO button, Auto Brightness Control (ABC), DisplayViewTM IT Suite In Plane Switching (IPS), 0 Watt in power save mode, ECO button, Auto Brightness Control (ABC), Display P22W-5 eCo iPs P19-5P eCo special features In Plane Switching (IPS), 0 Watt in power save mode, ECO

Ott, Albrecht

177

DOE Publishes Final Rule for the Request for Exclusion of 100 Watt R20 Short Incandescent Reflector Lamps from Energy Conservation Standards  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy has published a final rule regarding the request for exclusion of 100 Watt R20 short incandescent reflector lamps from energy conservation standards.

178

Hydrogen Cars and Water Vapor  

E-Print Network (OSTI)

. This cycle is currently under way with hydrogen fuel cells. As fuel cell cars are suggested as a solutionHydrogen Cars and Water Vapor D.W.KEITHANDA.E.FARRELL'S POLICY FORUM "Rethinking hydrogen cars" (18 misidentified as "zero-emissions vehicles." Fuel cell vehicles emit water vapor. A global fleet could have

Colorado at Boulder, University of

179

Fuel vapor control device  

SciTech Connect

A fuel vapor control device is described having a valve opening and closing a passage connecting a carburetor and a charcoal canister according to a predetermined temperature. A first coil spring formed by a ''shape memory effect'' alloy is provided to urge the valve to open the passage when the temperature is high. A second coil spring urges the valve to close the passage. A solenoid is provided to urge an armature against the valve to close the passage against the force of the first coil spring when the engine is running. The solenoid heats the first coil spring to generate a spring force therein when the engine is running. When the engine is turned off, the solenoid is deactivated, and the force of the first spring overcomes the force of the second spring to open the passage until such time as the temperature of the first spring drops below the predetermined temperature.

Ota, I.; Nishimura, Y.; Nishio, S.; Yogo, K.

1987-10-20T23:59:59.000Z

180

The Dust Settles on Water Vapor Feedback  

Science Journals Connector (OSTI)

...To understand water vapor feedback...shifts in the atmospheric circulation...caused a positive water vapor feedback...temperature. Condensation, evaporation...shifts in the atmospheric circulation...caused a positive water vapor feedback...temperature. Condensation, evaporation...

Anthony D. Del Genio

2002-04-26T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Category:Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

search GEOTHERMAL ENERGYGeothermal Home Geothermalpower.jpg Looking for the Mercury Vapor page? For detailed information on Mercury Vapor as exploration techniques,...

182

It's Elemental - The Element Sodium  

NLE Websites -- All DOE Office Websites (Extended Search)

Neon Neon Previous Element (Neon) The Periodic Table of Elements Next Element (Magnesium) Magnesium The Element Sodium [Click for Isotope Data] 11 Na Sodium 22.98976928 Atomic Number: 11 Atomic Weight: 22.98976928 Melting Point: 370.95 K (97.80°C or 208.04°F) Boiling Point: 1156 K (883°C or 1621°F) Density: 0.97 grams per cubic centimeter Phase at Room Temperature: Solid Element Classification: Metal Period Number: 3 Group Number: 1 Group Name: Alkali Metal What's in a name? From the English word soda and from the Medieval Latin word sodanum, which means "headache remedy." Sodium's chemical symbol comes from the Latin word for sodium carbonate, natrium. Say what? Sodium is pronounced as SO-dee-em. History and Uses: Although sodium is the sixth most abundant element on earth and comprises

183

Java Collections 2001 D.A. Watt and D.F. Brown 3-1 Solutions to Exercises in Chapter 3  

E-Print Network (OSTI)

Java Collections © 2001 D.A. Watt and D.F. Brown 3-1 Solutions to Exercises in Chapter 3 3 the character array a[left...right] is a palindrome: #12;Java Collections © 2001 D.A. Watt and D.F. Brown 3-2 1

Watt, David A.

184

Four Current Meter Models Compared in Strong Currents in Drake Passage D. RANDOLPH WATTS, MAUREEN A. KENNELLY, KATHLEEN A. DONOHUE,  

E-Print Network (OSTI)

Four Current Meter Models Compared in Strong Currents in Drake Passage D. RANDOLPH WATTS, MAUREEN A February 2013, in final form 11 June 2013) ABSTRACT Seven current meters representing four models: two vector-measuring current meters (VMCMs), two Aanderaa recording current meter (RCM) 11s, two

Rhode Island, University of

185

Policy on the Moderation of Assessment: Approved by the Senate, 22 May 2013 Heriot-Watt University  

E-Print Network (OSTI)

1 Policy on the Moderation of Assessment: Approved by the Senate, 22 May 2013 Heriot-Watt University Policy on the Moderation of Assessment With diversity in form of assessment across multi in all disciplines, across all Schools and in all modes or locations of study. The University Policy

Painter, Kevin

186

Introduction The Fiber-Lite MI-150 is a 150 Watt quartz halogen fiber optic illuminator designed for general microscopy  

E-Print Network (OSTI)

Introduction ® The Fiber-Lite MI-150 is a 150 Watt quartz halogen fiber optic illuminator designed for general microscopy use. When used with specialty fiber optic cables the MI-150 illuminator can also Illuminator from the carton and retain the manual and any additional documents. ! Remove the fiber optic cable

Kleinfeld, David

187

Heriot-Watt University has consolidated and updated its various logos to form a single more distinctive identity.  

E-Print Network (OSTI)

Brand Identity USING THE LOGO It is essential that a consistent use of colour and positioning-Watt Brand Identity. The logo should always appear in Pantone 293 and 30% Pantone 293 with a white keyline, it is necessary to consider the printers normal image parameters. The logo should therefore be positioned using

Glasbey, Chris

188

Vapor deposition of hardened niobium  

DOE Patents (OSTI)

A method of coating ceramic nuclear fuel particles containing a major amount of an actinide ceramic in which the particles are placed in a fluidized bed maintained at ca. 800.degree. to ca. 900.degree. C., and niobium pentachloride vapor and carbon tetrachloride vapor are led into the bed, whereby niobium metal is deposited on the particles and carbon is deposited interstitially within the niobium. Coating apparatus used in the method is also disclosed.

Blocher, Jr., John M. (Columbus, OH); Veigel, Neil D. (Columbus, OH); Landrigan, Richard B. (Columbus, OH)

1983-04-19T23:59:59.000Z

189

Unsteady aspects of sodiumwaterair reaction  

Science Journals Connector (OSTI)

One important issue for the Sodium Fast Reactor (SFR) concept is the reactivity of metallic sodium and its exothermal reaction with water. In particular during equipments washing operations, sodium needs to be firstly converted (destroyed) into non reactive species via a chemical reaction with water. Today, such operations are performed in tanks that confine the system and mitigate the consequences of any possible abnormal condition. Some data were obtained from experiments run by the French Commissariat lEnergie Atomique et aux Energies Alternatives (CEA) and were used as a basis for modelling. Among the principal phenomena identified so far are rapid water vaporization, hydrogen emission and explosion in air. High explosive-like pressure waves are generated from which sodium fragmentation and dispersion in water may ensue increasing the overall reactivity. It is extremely important to clarify the phenomenology to allow realistic extrapolation to full scale plants. A state of the art is proposed in this paper, starting from available experimental data and present perception of the physics. A comparison with present modelling strategy is also performed, underlining the necessity to improve a different and more physical approach aimed to well represent dynamic aspects of reaction.

Sofia Carnevali; Christophe Proust; Michel Soucille

2013-01-01T23:59:59.000Z

190

Chemical vapor deposition sciences  

SciTech Connect

Chemical vapor deposition (CVD) is a widely used method for depositing thin films of a variety of materials. Applications of CVD range from the fabrication of microelectronic devices to the deposition of protective coatings. New CVD processes are increasingly complex, with stringent requirements that make it more difficult to commercialize them in a timely fashion. However, a clear understanding of the fundamental science underlying a CVD process, as expressed through computer models, can substantially shorten the time required for reactor and process development. Research scientists at Sandia use a wide range of experimental and theoretical techniques for investigating the science of CVD. Experimental tools include optical probes for gas-phase and surface processes, a range of surface analytic techniques, molecular beam methods for gas/surface kinetics, flow visualization techniques and state-of-the-art crystal growth reactors. The theoretical strategy uses a structured approach to describe the coupled gas-phase and gas-surface chemistry, fluid dynamics, heat and mass transfer of a CVD process. The software used to describe chemical reaction mechanisms is easily adapted to codes that model a variety of reactor geometries. Carefully chosen experiments provide critical information on the chemical species, gas temperatures and flows that are necessary for model development and validation. This brochure provides basic information on Sandia`s capabilities in the physical and chemical sciences of CVD and related materials processing technologies. It contains a brief description of the major scientific and technical capabilities of the CVD staff and facilities, and a brief discussion of the approach that the staff uses to advance the scientific understanding of CVD processes.

NONE

1992-12-31T23:59:59.000Z

191

Sodium loop framework structural analysis  

SciTech Connect

This document provides the structural analysis of the Sodium Loop framework in a drop condition. The drop is similar to the US Department of Transportation non-bulk, performance-oriented packaging (Packaging Group I) drop test. The drop height evaluated for the Sodium Loop framework is 5.9 ft.

Nguyen, P.M.

1995-06-06T23:59:59.000Z

192
193

The Vaporization Enthalpies and Vapor Pressures of Some Primary Amines of Pharmaceutical Importance by Correlation Gas  

E-Print Network (OSTI)

by Correlation Gas Chromatography Chase Gobble, Nigam Rath, and James Chickos* Department of Chemistry Information ABSTRACT: Vapor pressures, vaporization, and sublimation enthalpies of several pharmaceuticals and boiling temperatures when available. Sublimation enthalpies and vapor pressures are also evaluated for 1

Chickos, James S.

194

Tables of thermodynamic properties of sodium  

SciTech Connect

The thermodynamic properties of saturated sodium, superheated sodium, and subcooled sodium are tabulated as a function of temperature. The temperature ranges are 380 to 2508 K for saturated sodium, 500 to 2500 K for subcooled sodium, and 400 to 1600 K for superheated sodium. Tabulated thermodynamic properties are enthalpy, heat capacity, pressure, entropy, density, instantaneous thermal expansion coefficient, compressibility, and thermal pressure coefficient. Tables are given in SI units and cgs units.

Fink, J.K.

1982-06-01T23:59:59.000Z

195

COSTBI-935; NO. OF PAGES 6 Please cite this article in press as: Oates J, Watts A. Uncovering the intimate relationship between lipids, cholesterol and GPCR activation, Curr Opin Struct Biol (2011), doi:10.1016/  

E-Print Network (OSTI)

COSTBI-935; NO. OF PAGES 6 Please cite this article in press as: Oates J, Watts A. Uncovering between lipids, cholesterol and GPCR activation Joanne Oates and Anthony Watts The membrane bilayer has, Department of Biochemistry, University of Oxford, Oxford OX1 3QU, UK Corresponding author: Watts, Anthony

Watts, Anthony

196

Watts Bar Unit 1 Cycle Zero Power Physics Tests Analysis with VERA-CS  

SciTech Connect

The Consortium for Advanced Simulation of Light Water Reactors (CASL) is developing a collection of methods and software products known as VERA, the Virtual Environment for Reactor Applications, including a core simulation capability called VERA-CS. A key milestone for this endeavor is to validate VERA against measurements from operating nuclear power reactors. The first step in validation against plant data is to determine the ability of VERA to accurately simulate the initial startup physics tests for Watts Bar Nuclear Power Station, Unit 1 (WBN1) cycle 1. VERA-CS calculations were performed with the Insilico code developed at ORNL using cross section processing from the SCALE system and the transport capabilities within the Denovo transport code using the SPN method. The calculations were performed with ENDF/B-VII.0 cross sections in 252 groups (collapsed to 23 groups for the 3D transport solution). The key results of the comparison of calculations with measurements include initial criticality, control rod worth critical configurations, control rod worth, differential boron worth, and isothermal temperature reactivity coefficient (ITC). The VERA results for these parameters show good agreement with measurements, with the exception of the ITC, which requires additional investigation. Results are also compared to those obtained with Monte Carlo methods and a current industry core simulator.

Gehin, Jess C [ORNL; Godfrey, Andrew T [ORNL; Evans, Thomas M [ORNL; Hamilton, Steven P [ORNL; Francheschini, F. [Westinghouse Electric Company, Cranberry Township

2014-01-01T23:59:59.000Z

197

Simulation of Watts Bar Unit 1 Initial Startup Tests with Continuous Energy Monte Carlo Methods  

SciTech Connect

The Consortium for Advanced Simulation of Light Water Reactors* is developing a collection of methods and software products known as VERA, the Virtual Environment for Reactor Applications. One component of the testing and validation plan for VERA is comparison of neutronics results to a set of continuous energy Monte Carlo solutions for a range of pressurized water reactor geometries using the SCALE component KENO-VI developed by Oak Ridge National Laboratory. Recent improvements in data, methods, and parallelism have enabled KENO, previously utilized predominately as a criticality safety code, to demonstrate excellent capability and performance for reactor physics applications. The highly detailed and rigorous KENO solutions provide a reliable nu-meric reference for VERAneutronics and also demonstrate the most accurate predictions achievable by modeling and simulations tools for comparison to operating plant data. This paper demonstrates the performance of KENO-VI for the Watts Bar Unit 1 Cycle 1 zero power physics tests, including reactor criticality, control rod worths, and isothermal temperature coefficients.

Godfrey, Andrew T [ORNL; Gehin, Jess C [ORNL; Bekar, Kursat B [ORNL; Celik, Cihangir [ORNL

2014-01-01T23:59:59.000Z

198

Independent Oversight Review, Sodium Bearing Waste Treatment...  

Energy Savers (EERE)

Federal - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Federal - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project -...

199

Independent Oversight Review, Sodium Bearing Waste Treatment...  

Energy Savers (EERE)

Contractor - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Contractor - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project...

200

Town of Bargersville, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Bargersville, Indiana (Utility Company) Bargersville, Indiana (Utility Company) Jump to: navigation, search Name Town of Bargersville Place Indiana Utility Id 1208 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial General Service Commercial Outdoor Lighting- 100 watt high pressure sodium Lighting Outdoor Lighting- 175 Watt Mercury Vapor Lighting Outdoor Lighting- 400 watt high pressure sodium Lighting Outdoor Lighting- 400 watt mercury vapor (directional) Lighting Outdoor Lighting- 400 watt mercury vapor (round) Lighting

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Heart of Texas Electric Coop | Open Energy Information  

Open Energy Info (EERE)

of Texas Electric Coop of Texas Electric Coop Jump to: navigation, search Name Heart of Texas Electric Coop Place Texas Utility Id 55982 Utility Location Yes Ownership C NERC ERCOT Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Bulb Lighting 1000 Watt High Pressure Sodium Bulb (Closed Rate) Lighting 175 Watt Mercury Vapor Bulb (Closed Rate) Lighting 175 Watt Mercury Vapor Bulb (Closed Rate) - street lighting Lighting 400 Watt High Pressure Sodium Bulb (Closed Rate) Lighting Commercial Single Phase <24.99 KW Commercial

202

Simulation of sodium boiling experiments with THERMIT sodium version  

E-Print Network (OSTI)

Natural and forced convection experiments(SBTF and French) are simulated with the sodium version of the thermal-hydraulic computer code THERMIT. Simulation is done for the test secti- -on with the pressure-velocity boundary ...

Huh, Kang Yul

1982-01-01T23:59:59.000Z

203

VAPORIZATION THERMODYNAMICS OF KCl. COMBINING VAPOR PRESSURE AND GRAVIMETRIC DATA  

E-Print Network (OSTI)

.B. Department of Chemistry, Moscow State University, Moscow, 119899, Russia Bonnell D.W., Hastie J.W. National temperature chemistry situations, vapor pressures are typically less than 100 kPa. The molar volume is p = 101325 Pa). The subscript trs denotes that the changeisfor a transition, typically sublimation

Rudnyi, Evgenii B.

204

Town of Selma, North Carolina (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Selma Selma Place North Carolina Utility Id 16914 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes ISO Other Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 W Sodium Vapor/ Semi-enclosed Lighting AREA LIGHTING - 22,000 Lumen Sodium Vapor Lighting AREA LIGHTING - 250 Watt HPS Lighting AREA LIGHTING - 250 Watt HPS with decorative pole Lighting AREA LIGHTING - 27,500 Lumen Sodium Vapor Colbra-head Lighting AREA LIGHTING - 27,500 Lumen Sodium Vapor Flood Lighting AREA LIGHTING - 400 Watt HPS with decorative pole Lighting

205

Ground beef shelf life assessment as influenced by sodium lactate, sodium propionate, sodium diacetate, and soy protein concentrate  

E-Print Network (OSTI)

In phase I all-beef and soy-added ground beef patties containing sodium lactate, sodium propionate, and sodium diacetate at various levels and combinations were stored for nine months at -10C. Upon cooking, the addition of sodium lactate increased...

Grones, Kelly Leann

2012-06-07T23:59:59.000Z

206

Vacuum vapor deposition gun assembly  

DOE Patents (OSTI)

A vapor deposition gun assembly includes a hollow body having a cylindrical outer surface and an end plate for holding an adjustable heat sink, a hot hollow cathode gun, two magnets for steering the plasma from the gun into a crucible on the heat sink, and a shutter for selectively covering and uncovering the crucible.

Zeren, Joseph D. (Boulder, CO)

1985-01-01T23:59:59.000Z

207

LNG Vaporizer Utilizing Vacuum Steam Condensing  

Science Journals Connector (OSTI)

This report concerns the field test results of a new type of peak-shaving LNG vaporizer (VSV) whose heat source is ... heat of vacuum steam to vaporize and superheat LNG within heat transfer tubes. Prior to the.....

Y. Miyata; M. Hanamure; H. Kujirai; Y. Sato

1991-01-01T23:59:59.000Z

208

Running-Film Vaporizer for LNG  

Science Journals Connector (OSTI)

Advances in welding technology and steel fabrication techniques have permitted the development of a new concept in cryogenic vaporizersthe running-film plate vaporizer. Although similar in heat transfer philosop...

H. H. West; G. L. Puckett

1975-01-01T23:59:59.000Z

209

Vapor Retarder Classification- Building America Top Innovation  

Energy.gov (U.S. Department of Energy (DOE))

This Building America Innovations profile describes research in vapor retarders. Since 2006 the IRC has permitted Class III vapor retarders like latex paint (see list above) in all climate zones under certain conditions thanks to research by Building America teams.

210

Vapor phase modifiers for oxidative coupling  

DOE Patents (OSTI)

Volatilized metal compounds retard vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, Barbara K. (Charleston, WV)

1991-01-01T23:59:59.000Z

211

City of Greendale, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Greendale, Indiana (Utility Company) Greendale, Indiana (Utility Company) Jump to: navigation, search Name City of Greendale Place Indiana Utility Id 6907 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service Commercial Flasher Signal Lighting Municipal street light service - 100 Watt Sodium Vapor Lighting Municipal street light service - 175 Watt Mercury Vapor Lighting Municipal street light service - 250 Watt Mercury Vapor Lighting Municipal street light service - 250 Watt Sodium Vapor Lighting

212

Vapor Pressures and Heats of Vaporization of Primary Coal Tars  

Office of Scientific and Technical Information (OSTI)

/ PC92544-18 / PC92544-18 VAPOR PRESSURES AND HEATS OF VAPORIZATION OF PRIMARY COAL TARS FINAL REPORT Grant Dates: August, 1992 - November, 1996 Principal Authors: Eric M. Suuberg (PI) and Vahur Oja Report Submitted: April, 1997 Revised: July, 1997 Grant Number: DE-FG22-92PC92544 Report Submitted by: ERIC M. SUUBERG DIVISION OF ENGINEERING BROWN UNIVERSITY PROVIDENCE, RI 02912 TEL. (401) 863-1420 Prepared For: U. S. DEPT. OF ENERGY FEDERAL ENERGY TECHNOLOGY CENTER P.O. BOX 10940 PITTSBURGH, PA 15236 DR. KAMALENDU DAS, FETC, MORGANTOWN , WV TECHNICAL PROJECT OFFICER "US/DOE Patent Clearance is not required prior to the publication of this document" ii United States Government Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any

213

Vapor deposition of tantalum and tantalum compounds  

SciTech Connect

Tantalum, and many of its compounds, can be deposited as coatings with techniques ranging from pure, thermal chemical vapor deposition to pure physical vapor deposition. This review concentrates on chemical vapor deposition techniques. The paper takes a historical approach. The authors review classical, metal halide-based techniques and current techniques for tantalum chemical vapor deposition. The advantages and limitations of the techniques will be compared. The need for new lower temperature processes and hence new precursor chemicals will be examined and explained. In the last section, they add some speculation as to possible new, low-temperature precursors for tantalum chemical vapor deposition.

Trkula, M. [Los Alamos National Lab., NM (United States). Materials Science and Technology Div.

1996-04-01T23:59:59.000Z

214

Means and method for vapor generation  

DOE Patents (OSTI)

A liquid, in heat transfer contact with a surface heated to a temperature well above the vaporization temperature of the liquid, will undergo a multiphase (liquid-vapor) transformation from 0% vapor to 100% vapor. During this transition, the temperature driving force or heat flux and the coefficients of heat transfer across the fluid-solid interface, and the vapor percentage influence the type of heating of the fluid--starting as "feedwater" heating where no vapors are present, progressing to "nucleate" heating where vaporization begins and some vapors are present, and concluding with "film" heating where only vapors are present. Unstable heating between nucleate and film heating can occur, accompanied by possibly large and rapid temperature shifts in the structures. This invention provides for injecting into the region of potential unstable heating and proximate the heated surface superheated vapors in sufficient quantities operable to rapidly increase the vapor percentage of the multiphase mixture by perhaps 10-30% and thereby effectively shift the multiphase mixture beyond the unstable heating region and up to the stable film heating region.

Carlson, Larry W. (Oswego, IL)

1984-01-01T23:59:59.000Z

215

The Sodium-Restricted Diet  

E-Print Network (OSTI)

The value of salt has long been known. Feuds and wars were waged for the possession of salt during man's early development. The common expressions "salt of the earth" and "worth his weight in salt" all show the high value placed on salt. Taxes were... collected for possession of salt. Even the word "salary" is connected with salt. Salt remains valuable to us as a source of sodium, an essential nutrient needed by our body to function properly. The body needs sodium to form tissue - to aid a child...

Anonymous,

1979-01-01T23:59:59.000Z

216

Vapor-Particle Separation Using Microporous Metallic Membrane in Crossflow Filtration  

SciTech Connect

Simultaneous separation of vapor and particles in industrial processes could be a key step toward manufacturing of high-quality goods. The separation is critical for successful measurement of volatile or semi-volatile aerosol particles, which no reliable technique exists. We have developed a technique for separation of vapor and particles simultaneously using a specialty microporous metallic membrane. The separator allows the thermally denuded particles traverse straight through the membrane tube, while the vapor molecules permeate through the membrane, separate from the particles and are removed subsequently. The separation technique virtually eliminates the possibility of contamination by vapor re- condensation. We tested the prototype of the vapor-particle separator (VPS) using aerosols prepared from sodium chloride to represent non-volatile aerosols. Chemical like dioctyl phthalate was chosen to represent volatile particles. The test aerosol particles were generated by an atomizer followed by a tandem differential mobility analyser to produce a stream of monodisperse particles in the size range of 10 to 100 nm. In real world particles, we tested the VPS using diesel engine particles that is a mixture of complex chemical composition. Number concentration of the nonvolatile particles reduced as the temperature increased, but the mode diameter of the aerosol population remained unchanged. Number concentration of the volatile particles was also reduced as the temperature increased, but their mode diameters became smaller as particles shrunk in diameter. Differences in the thermal behaviour of the particles were attributed to its transition energy barrier and evaporation rate. Mass balance analysis suggests the separation of vapor and test particles was reasonably complete. Thus, we conclude the VPS could provide an effective means for quantitative characterization of aerosol volatility and separation of vapors from particles.

Cheng, Mengdawn [ORNL] [ORNL

2013-01-01T23:59:59.000Z

217

Technical Information on the Carbonation of the EBR-II Reactor, Summary Report Part 2: Application to EBR-II Primary Sodium System and Related Systems  

SciTech Connect

Residual sodium is defined as sodium metal that remains behind in pipes, vessels, and tanks after the bulk sodium metal has been melted and drained from such components. The residual sodium has the same chemical properties as bulk sodium, and differs from bulk sodium only in the thickness of the sodium deposit. Typically, sodium is considered residual when the thickness of the deposit is less than 5-6 cm. This residual sodium must be removed or deactivated when a pipe, vessel, system, or entire reactor is permanently taken out of service, in order to make the component or system safer and/or to comply with decontamination and decomissioning regulations. As an alternative to the established residual sodium deactivation techniques (steam-and-nitrogen, wet vapor nitrogen, etc.), a technique involving the use of moisture and carbon dioxide has been developed. With this technique, sodium metal is converted into sodium bicarbonate by reacting it with humid carbon dioxide. Hydrogen is emitted as a by-product. This technique was first developed in the laboratory by exposing sodium samples to humidifed carbon dioxide under controlled conditions, and then demonstrated on a larger scale by treating residual sodium within the Experimental Breeder Reactor II (EBR-II) secondary cooling system, followed by the primary cooling system, respectively. The EBR-II facility is located at the Idaho National Laboratory (INL) in southeastern Idaho, USA. This report is Part 2 of a two-part report. This second report provides a supplement to the first report and describes the application of the humdidified carbon dioxide technique ("carbonation") to the EBR-II primary tank, primary cover gas systems, and the intermediate heat exchanger. Future treatment plans are also provided.

Steven R. Sherman; Collin J. Knight

2006-03-01T23:59:59.000Z

218

Surface-Driven Sodium Ion Energy Storage in Nanocellular Carbon...  

NLE Websites -- All DOE Office Websites (Extended Search)

Surface-Driven Sodium Ion Energy Storage in Nanocellular Carbon Foams. Surface-Driven Sodium Ion Energy Storage in Nanocellular Carbon Foams. Abstract: Sodium ion (Na+) batteries...

219

Wick for metal vapor laser  

DOE Patents (OSTI)

An improved wick for a metal vapor laser is made of a refractory metal cylinder, preferably molybdenum or tungsten for a copper laser, which provides the wicking surface. Alternately, the inside surface of the ceramic laser tube can be metalized to form the wicking surface. Capillary action is enhanced by using wire screen, porous foam metal, or grooved surfaces. Graphite or carbon, in the form of chunks, strips, fibers or particles, is placed on the inside surface of the wick to reduce water, reduce metal oxides and form metal carbides.

Duncan, David B. (Livermore, CA)

1992-01-01T23:59:59.000Z

220

Non-Vapor Compression HVAC Technologies Report  

Energy.gov (U.S. Department of Energy (DOE))

While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. The Building Technologies Office is evaluating low-global warming potential (GWP) alternatives to vapor-compression technologies.

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Mercury Vapor (Kooten, 1987) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor (Kooten, 1987) Mercury Vapor (Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor (Kooten, 1987) Exploration Activity Details Location Unspecified Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Surface soil-mercury surveys are an inexpensive and useful exploration tool for geothermal resources. ---- Surface geochemical surveys for mercury were conducted in 16 areas in 1979-1981 by ARCO Oil and Gas Company as part of its geothermal evaluation program. Three techniques used together have proved satisfactory in evaluating surface mercury data. These are contouring, histograms and cumulative frequency plots of the data. Contouring geochemical data and constructing histograms are standard

222

Vapor phase modifiers for oxidative coupling  

DOE Patents (OSTI)

Volatilized metal compounds are described which are capable of retarding vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, B.K.

1991-12-17T23:59:59.000Z

223

Data:D32b9210-612f-484b-888b-4eb9cb43e3da | Open Energy Information  

Open Energy Info (EERE)

612f-484b-888b-4eb9cb43e3da 612f-484b-888b-4eb9cb43e3da No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-400 W SV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

224

Data:B1abc200-9467-4663-ad52-ef845d920429 | Open Energy Information  

Open Energy Info (EERE)

abc200-9467-4663-ad52-ef845d920429 abc200-9467-4663-ad52-ef845d920429 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-100 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

225

Data:9b11a6a4-b93e-48bf-8860-1d22715f115f | Open Energy Information  

Open Energy Info (EERE)

-b93e-48bf-8860-1d22715f115f -b93e-48bf-8860-1d22715f115f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-400 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

226

Near real time vapor detection and enhancement using aerosol adsorption  

SciTech Connect

A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

Novick, Vincent J.; Johnson, Stanley A.

1997-12-01T23:59:59.000Z

227

Near real time vapor detection and enhancement using aerosol adsorption  

DOE Patents (OSTI)

A vapor sample detection method is described where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample. 13 figs.

Novick, V.J.; Johnson, S.A.

1999-08-03T23:59:59.000Z

228

Near real time vapor detection and enhancement using aerosol adsorption  

DOE Patents (OSTI)

A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

Novick, Vincent J. (Downers Grove, IL); Johnson, Stanley A. (Countryside, IL)

1999-01-01T23:59:59.000Z

229

G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) Value-Added Product  

SciTech Connect

The G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) value-added product (VAP) computes precipitable water vapor using neural network techniques from data measured by the GVR. The GVR reports time-series measurements of brightness temperatures for four channels located at 183.3 1, 3, 7, and 14 GHz.

Koontz, A; Cadeddu, M

2012-12-05T23:59:59.000Z

230

Environmental test report on the CTI-Cryogenics 1-watt integral Stirling cooler (long-life HD-1033d). Final report, 16 June-24 July 1988  

SciTech Connect

This final report describes and provides the data on the environmental testing of the CTI-Cryogenics 1-Watt Integral Stirling Cooler (Long-Life HD-1033D). The 1-Watt Integral Cooler (HD-1033B/C) is currently used in the M1 FLIR, M60 FLIR, and the Advanced Attack Helicopter FLIR. The long life cooler (clearance seal) improves life of the cooler by approximately two and one half times. C2NVEO evaluated the cooler performance at environmental extremes per the purchase description, PD-0182-001(CR). The cooler successfully passed all the environmental tests with no failures.

Doggett, G.; Dunmire, H.; Samuels, R.; Shaffer, J.

1989-04-01T23:59:59.000Z

231

Quantitative organic vapor-particle sampler  

DOE Patents (OSTI)

A quantitative organic vapor-particle sampler for sampling semi-volatile organic gases and particulate components. A semi-volatile organic reversible gas sorbent macroreticular resin agglomerates of randomly packed microspheres with the continuous porous structure of particles ranging in size between 0.05-10 .mu.m for use in an integrated diffusion vapor-particle sampler.

Gundel, Lara (Berkeley, CA); Daisey, Joan M. (Walnut Creek, CA); Stevens, Robert K. (Cary, NC)

1998-01-01T23:59:59.000Z

232

LNG fire and vapor control system technologies  

SciTech Connect

This report provides a review of fire and vapor control practices used in the liquefied natural gas (LNG) industry. Specific objectives of this effort were to summarize the state-of-the-art of LNG fire and vapor control; define representative LNG facilities and their associated fire and vapor control systems; and develop an approach for a quantitative effectiveness evaluation of LNG fire and vapor control systems. In this report a brief summary of LNG physical properties is given. This is followed by a discussion of basic fire and vapor control design philosophy and detailed reviews of fire and vapor control practices. The operating characteristics and typical applications and application limitations of leak detectors, fire detectors, dikes, coatings, closed circuit television, communication systems, dry chemicals, water, high expansion foam, carbon dioxide and halogenated hydrocarbons are described. Summary descriptions of a representative LNG peakshaving facility and import terminal are included in this report together with typical fire and vapor control systems and their locations in these types of facilities. This state-of-the-art review identifies large differences in the application of fire and vapor control systems throughout the LNG industry.

Konzek, G.J.; Yasutake, K.M.; Franklin, A.L.

1982-06-01T23:59:59.000Z

233

ARM - Field Campaign - Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 2000.09.18 - 2000.10.08 Lead Scientist : Henry Revercomb Data Availability Yes For data sets, see below. Description Scientific hypothesis: 1. Microwave radiometer (MWR) observations of the 22 GHz water vapor line can accurately constrain the total column amount of water vapor (assuming a calibration accuracy of 0.5 degC or better, which translates into 0.35 mm PWV). 2. Continuous profiling by Raman lidar provides a stable reference for handling sampling problems and observes a fixed column directly above the site only requiring a single height- independent calibration factor. 3. Agreement between the salt-bath calibrated in-situ probes, chilled

234

Energy balance in laser-irradiated vaporizing droplets  

Science Journals Connector (OSTI)

The interactions of vaporizing aerosols with a high energy laser beam are analyzed in the diffusive vaporization regime. This is the regime in which diffusive mass transport and...

Zardecki, Andrew; Armstrong, Robert L

1988-01-01T23:59:59.000Z

235

Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Gravity Survey At Cove Fort Area - Vapor (Warpinski, Et...

236

Hydrogen-Bond Acidic Polymers for Chemical Vapor Sensing. | EMSL  

NLE Websites -- All DOE Office Websites (Extended Search)

Acidic Polymers for Chemical Vapor Sensing. Hydrogen-Bond Acidic Polymers for Chemical Vapor Sensing. Abstract: A review with 171 references. Hydrogen-bond acidic polymers for...

237

Gelcasting Polycrystalline Alumina  

SciTech Connect

OSRAM SYLVANIA INC. is a major U.S. manufacturer of high-intensity lighting. Among its products is the Lumalux TM line of high-pressure sodium vapor arc lamps, which are used for industrial, highway, and street lighting. The key to the performance of these lamps is the polycrystalline alumina (PCA) tube that is used to contain the plasma that is formed in the electric arc. That plasma consists of ionized sodium, mercury, and xenon vapors. The key attributes of the PCA tubes are their transparency ({approximately}97% total transmittance in the visible), their refractoriness (inner wall temperature can reach l2OOC), and their chemical resistance (sodium and mercury vapor are extremely corrosive). The current efficiency of the lamps is very high, up to 100 initial lumens per watt. (Compare incandescent lamps 10-20 lumens per watt, fluorescent lamps 25-90 lumens per watt.)

Janney, M.A.; Zuk, K.J.; Wei, G.C.

2000-01-01T23:59:59.000Z

238

POLICY ON STAFF USE OF WEB 2.0 TECHNOLOGIES Heriot-Watt University encourages staff to make appropriate use of Web 2.0 technologies in  

E-Print Network (OSTI)

POLICY ON STAFF USE OF WEB 2.0 TECHNOLOGIES Summary Heriot-Watt University encourages staff to make appropriate use of Web 2.0 technologies in work and private life. In order to promote student and staff safety and reduce legal, operational, financial and reputational risk to the University, all staff who use Web 2

Howie, Jim

239

Advanced Security Infrastructures for Grid Education Prof R.O. Sinnott, A.J. Stell, Dr J.P. Watt, Prof D.W. Chadwick,  

E-Print Network (OSTI)

Advanced Security Infrastructures for Grid Education Prof R.O. Sinnott, A.J. Stell, Dr J.P. Watt domain. Keywords: Grid, education, Security, PERMIS, Shibboleth. 1. Introduction As Grid technology addressing these challenges. This is one of the first full Grid computing courses available today. Security

Kent, University of

240

Recovering hydrocarbons from hydrocarbon-containing vapors  

DOE Patents (OSTI)

Values are recovered from a hydrocarbon-containing vapor by contacting the vapor with quench liquid consisting essentially of hydrocarbons to form a condensate and a vapor residue, the condensate and quench fluid forming a combined liquid stream. The combined liquid stream is mixed with a viscosity-lowering liquid to form a mixed liquid having a viscosity lower than the viscosity of the combined liquid stream to permit easy handling of the combined liquid stream. The quench liquid is a cooled portion of the mixed liquid. Viscosity-lowering liquid is separated from a portion of the mixed liquid and cycled to form additional mixed liquid.

Mirza, Zia I. (La Verne, CA); Knell, Everett W. (Los Alamitos, CA); Winter, Bruce L. (Danville, CA)

1980-09-30T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Independent Oversight Assessment, Idaho Cleanup Project Sodium...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Bearing Waste Treatment Project - November 2012 November 2012 Assessment of Nuclear Safety Culture at the Idaho Cleanup Project Sodium Bearing Waste Treatment Project This...

242

Viscosity of Liquid Sodium and Potassium  

Science Journals Connector (OSTI)

2 November 1936 research-article Viscosity of Liquid Sodium and Potassium Y. S. Chiong The Royal Society is collaborating with JSTOR to digitize, preserve, and extend...

1936-01-01T23:59:59.000Z

243

Sodium sulfide leaching of low-grade jamesonite concentrate in production of sodium pyroantimoniate  

Science Journals Connector (OSTI)

Sodium sulfide leaching of a low-grade jamesonite concentrate in the production of sodium pyroantimoniate through the air oxidation process and the influencing factors on the leaching rate of antimony were...

Tian-zu Yang PhD; Ming-xi Jiang

2005-06-01T23:59:59.000Z

244

Aerogel composites using chemical vapor infiltration  

NLE Websites -- All DOE Office Websites (Extended Search)

Aerogel composites using chemical vapor infiltration Aerogel composites using chemical vapor infiltration Title Aerogel composites using chemical vapor infiltration Publication Type Journal Article Year of Publication 1995 Authors Hunt, Arlon J., Michael R. Ayers, and Wanqing Cao Journal Journal of Non-Crystalline Solids Volume 185 Pagination 227-232 Abstract A new method to produce novel composite materials based on the use of aerogels as a starting material is described. Using chemical vapor infiltration, a variety of solid materials were thermally deposited into the open pore structure of aerogel. The resulting materials possess new and unusual properties including photoluminescence, magnetism and altered optical properties. An important characteristic of this preparation process is the very small size of the deposits that gives rise to new behaviors. Silicon deposits exhibit photoluminescence, indicating quantum confinement. Two or more phases may be deposited simultaneously and one or both chemically or thermally reacted to produce new structures.

245

Chemical vapor detection using nanomechanical platform  

Science Journals Connector (OSTI)

For high sensitive and multiplexed chemical analysis, an opto-mechanical detection platform has been built. To check the performance of the platform, we performed water vapor response measurements for ... sensors...

S. H. Lim

2007-11-01T23:59:59.000Z

246

Chemical vapor deposition of functionalized isobenzofuran polymers  

E-Print Network (OSTI)

This thesis develops a platform for deposition of polymer thin films that can be further tailored by chemical surface modification. First, we explore chemical vapor deposition of functionalized isobenzofuran films using ...

Olsson, Ylva Kristina

2007-01-01T23:59:59.000Z

247

Recovery of acids and sodium hydroxide from solutions of sodium sulfate and sodium chloride with the use of bipolar membranes  

SciTech Connect

The authors examined the kinetic laws governing the electrodialysis recovery of hydrochloric acid and sulfuric acid, as well as sodium hydroxide, from 1M sodium chloride and 0.5 M sodium sulfate solutions and from a mixture of these salts with the use of the MB-1, MB-2, and MB-3 bipolar membranes. Kinetic plots of the current density and the concentration of the acid and the base in the chambers next to the bipolar membranes during the electrodialysis treatment of 1M sodium chloride, 0.5 M sodium sulfate, and solutions are presented. It was established that it is better to use the MB-3 membrane for the electrodialysis conversion of sodium chloride and sodium sulfate into acids and sodium hydroxide owing to the high rate and current efficiency and low expenditure of electrical energy and degree of contamination of the products obtained by the salts. It was also established that the resistance of the MB-1 and MB-2 bipolar membranes is almost an order of magnitude higher than that of the MB-3 membrane.

Bobrinskaya, G.A.; Pavlova, T.V.; Shatalov, A.Ya.

1985-09-01T23:59:59.000Z

248

Vapor Power Systems MAE 4263 Final Exam  

E-Print Network (OSTI)

Vapor Power Systems MAE 4263 Final Exam Wednesday, May 5, 2004 Prof. P.M. Moretti Key Instructions, then think, then write! 1. What is the dewpoint of the exhaust of your car, if the gasoline consists2 so that the mole fraction of water vapor is yH2 O = 9 9 + 8 + 47 = 0:14063 pH2 O = 0:14063 14

249

Optical monitor for water vapor concentration  

DOE Patents (OSTI)

A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma. 5 figs.

Kebabian, P.

1998-06-02T23:59:59.000Z

250

Optical monitor for water vapor concentration  

DOE Patents (OSTI)

A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma.

Kebabian, Paul (Acton, MA)

1998-01-01T23:59:59.000Z

251

Lamar County Elec Coop Assn | Open Energy Information  

Open Energy Info (EERE)

Lamar County Elec Coop Assn Lamar County Elec Coop Assn Place Texas Utility Id 10649 Utility Location Yes Ownership C NERC Location TRE Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png LARGE COMMERCIAL Commercial LARGE COMMERCIAL PUBLIC BUILDINGS Commercial RESIDENTIAL & PUBLIC BUILDINGS Residential SMALL COMMERCIAL Commercial security light- 100 watt High Pressure Sodium Lighting security light- 400 watt Metal Halide Lighting security light-1000 watt Mercury Vapor Lighting security light-1000 watt Metal Halide Lighting security light-175 watt Mercury Vapor Lighting

252

Tippah Electric Power Assn | Open Energy Information  

Open Energy Info (EERE)

Tippah Electric Power Assn Tippah Electric Power Assn Place Mississippi Utility Id 18943 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GSA 1 General Power Rate 1 Commercial GSA 2 General Power Rate 2 Commercial GSA 3 General Power Rate 3 Commercial LS Lighting High Pressure Sodium 100 Watts Lighting LS Lighting Mercury Vapor 175 Watts Lighting LS Lighting Mercury Vapor 400 Watts Lighting LS Lighting Metal Halide Cobrahead 400 Watts Lighting LS Lighting Metal Halide Floodlight 1000 Watts Lighting

253

Atlas Sodium Automated Batch Synthesis System  

E-Print Network (OSTI)

Atlas Sodium Automated Batch Synthesis System (Syrris) June 2013 #12;Introduction to the system · The Atlas Sodium system consists of an Atlas base equipped with a 400ºC hotplate, a stacking dry bath systemL) for automated addition and/or removal of solution. · The system is computer controlled by the Atlas software

Subramanian, Venkat

254

Sodium Heat Engine Development Program  

SciTech Connect

The Sodium Heat Engine (SHE) is an efficient thermoelectric conversion device which directly generates electricity from a thermally regenerative electrochemical cell that relies on the unique conduction properties of {beta}{double prime}-alumina solid electrolyte (BASE). Laboratory models of a variety of SHE devices have demonstrated the feasibility and efficiency of the system, engineering development of large prototype devices has been slowed by a series of materials and fabrication problems. Failure of the electrolyte tubes has been a recurring problem and a number of possible causes have been postulated. To address these issues, a two-phase engineering development program was undertaken. This report summarizes the final results of the first phase of the program, which included extensive materials characterization activities, a study of applicable nondestructive evaluation methods, an investigation of possible stress states that would contribute to fracture, and certain operational issues associated with the electromagnetic pumps used in the SHE prototype. Mechanical and microstructural evaluation of commercially obtained BASE tubes revealed that they should be adequate for SHE applications and that sodium exposure produced no appreciable deleterious strength effects. Processing activities to produce a more uniform and smaller grain size for the BASE tubes were completed using isostatic pressing, extrusion, and slip casting. Green tubes were sintered by conventional and microwave plasma methods. Of particular interest is the residual stress state in the BASE tubes, and both analysis and nondestructive evaluation methods were employed to evaluate these stresses. X-ray and neutron diffraction experiments were performed to determine the bulk residual stresses in commercially fabricated BASE tubes; however, tube-to-tube variations and variations among the various methods employed did not allow formulation of a definitive definition of the as-fabricated stress state.

Singh, J.P.; Kupperman, D.S.; Majumdar, S.; Dorris, S.; Gopalsami, N.; Dieckman, S.L.; Jaross, R.A.; Johnson, D.L.; Gregar, J.S.; Poeppel, R.B.; Raptis, A.C.; Valentin, R.A.

1992-01-01T23:59:59.000Z

255

Bowie-Cass Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Bowie-Cass Electric Coop, Inc Bowie-Cass Electric Coop, Inc Jump to: navigation, search Name Bowie-Cass Electric Coop, Inc Place Texas Utility Id 2049 Utility Location Yes Ownership C NERC Location SPP NERC SPP Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Large Power Service Commercial Industrial Large Power Service Industrial Residential Service Residential Schedule ADD-250 Watt High Pressure Sodium Lighting Schedule ADD-400 Watt Mercury vapor. Lighting Schedule DD-100 Watt High Pressure Sodium Lighting Schedule DD-175 Watt Mercury Vapor Lighting

256

City of Westerville, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

(Redirected from City of Westerville, OH) (Redirected from City of Westerville, OH) Jump to: navigation, search Name City of Westerville Place Westerville, Ohio Utility Id 20477 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Westerville, OH Smart Grid Project was awarded $4,320,000 Recovery Act Funding with a total project value of $10,663,000. Utility Rate Schedules Grid-background.png 175 watt mercury vapor light/100 watt high pressure sodium light(pole in place) Lighting 175 watt mercury vapor light/100 watt high pressure sodium light(city

257

Southern Pine Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Elec Coop, Inc Elec Coop, Inc Jump to: navigation, search Name Southern Pine Elec Coop, Inc Place Alabama Utility Id 17646 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Security Light: 100 Watt High Pressure Sodium (HPS) Lighting Security Light: 175 Watt Mercury Vapor Lighting Security Light: 400 Watt High Pressure Sodium (HPS) Lighting Security Light: 400 Watt Mercury Vapor Lighting Average Rates Residential: $0.1140/kWh Commercial: $0.0956/kWh Industrial: $0.0928/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

258

Bridger Valley Elec Assn, Inc | Open Energy Information  

Open Energy Info (EERE)

Wyoming Wyoming Utility Id 2215 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Irrigation Pumping Industrial Large General Service Single Phase Industrial Large Power (350 kVA or less) Industrial Large Power (350 kVA to 2000 kVA) Industrial Large Power (Over 2000 kVA) Industrial Lighting Service-100 watt High Pressure Sodium Lighting Lighting Service-175 watt Mercury Vapor Lamp Lighting Lighting Service-250 watt High Pressure Sodium Lighting Lighting Service-400 watt Mercury Vapor Lamp Lighting

259

City of Westerville, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name City of Westerville Place Westerville, Ohio Utility Id 20477 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Westerville, OH Smart Grid Project was awarded $4,320,000 Recovery Act Funding with a total project value of $10,663,000. Utility Rate Schedules Grid-background.png 175 watt mercury vapor light/100 watt high pressure sodium light(pole in place) Lighting 175 watt mercury vapor light/100 watt high pressure sodium light(city

260

Atchison-Holt Electric Coop | Open Energy Information  

Open Energy Info (EERE)

Atchison-Holt Electric Coop Atchison-Holt Electric Coop Jump to: navigation, search Name Atchison-Holt Electric Coop Place Missouri Utility Id 942 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes ISO Other Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt Sodium Lighting 175 Watt Mercury Vapor Lighting 250 Watt Sodium Lighting 400 Watt Mercury Vapor Lighting Commercial Multi-Phase Commercial Commercial Single-Phase Commercial Industrial Multi-Phase Industrial Irrigation Multi-Phase Commercial

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Halifax Electric Member Corp | Open Energy Information  

Open Energy Info (EERE)

Halifax Electric Member Corp Halifax Electric Member Corp Place North Carolina Utility Id 7978 Utility Location Yes Ownership C NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png MEDIUM GENERAL SERVICE Commercial NC GREENPOWER PROGRAM voluntary RENEWABLE ENERGY GENERATION-Solar RENEWABLE ENERGY GENERATION-Wind RESIDENTIAL SERVICE Residential SECURITY LIGHTING 100-watt high-pressure sodium Lighting SECURITY LIGHTING 140-watt LED Light Commercial SECURITY LIGHTING 175-watt mercury vapor Lighting SECURITY LIGHTING 175-watt metal halide Lighting SECURITY LIGHTING 250-watt high-pressure sodium Lighting

262

Town of Etna Green, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Etna Green, Indiana (Utility Company) Etna Green, Indiana (Utility Company) Jump to: navigation, search Name Town of Etna Green Place Indiana Utility Id 5928 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 150 watt Hi-Pressure Sodium Lighting 1500 watt Quartz Lighting 175 watt Mercury Vapor Lighting 250 watt Hi-Pressure Sodium Lighting 400 watt Metal Halide Lighting General Service Rate Metered Demand - Single Phase Commercial General Service Rate Metered Demand - Three Phase Commercial General Service Rate for Non-residential "GS" - Single Phase Commercial

263

A summary of the Planck constant measurements using a watt balance with a superconducting solenoid at NIST  

E-Print Network (OSTI)

Researchers at the National Institute of Standards and Technology have been using a watt balance, NIST-3, to measure the Planck constant $h$ for over ten years. Two recently published values disagree by more than one standard uncertainty. The motivation for the present manuscript is twofold. First, we correct the latest published number to take into account a recently discovered systematic error in mass dissemination at the Bureau International des Poids et Mesures (BIPM). Second, we provide guidance on how to combine the two numbers into one final result. In order to adequately reflect the discrepancy, we added an additional systematic uncertainty to the published uncertainty budgets. The final value of $h$ measured with NIST-3 is $h = 6.626\\,069\\,36(37)\\times 10^{-34}\\,\\mbox{J\\,s}$. This result is $77(57) \\times 10^{-9}$ fractionally higher than $h_{\\mathrm{90}}$. Each number in parentheses gives the value of the standard uncertainty in the last two digits of the respective value and $h_{\\mathrm{90}}$ is th...

Schlamminger, S; Haddad, D; Newell, D B; Seifert, F; Chao, L S; Liu, R; Williams, E R; Pratt, J R

2015-01-01T23:59:59.000Z

264

In-Situ Method for Treating Residual Sodium  

DOE Patents (OSTI)

A unique process for deactivating residual sodium in Liquid Metal Fast Breeder Reactor (LMFBR) systems which uses humidified (but not saturated) carbon dioxide at ambient temperature and pressure to convert residual sodium into solid sodium bicarbonate.

Sherman, Steven R.; Henslee, S. Paul

2005-07-19T23:59:59.000Z

265

In-situ method for treating residual sodium  

SciTech Connect

A unique process for deactivating residual sodium in Liquid Metal Fast Breeder Reactor (LMFBR) systems which uses humidified (but not saturated) carbon dioxide at ambient temperature and pressure to convert residual sodium into solid sodium bicarbonate.

Sherman, Steven R. (Idaho Falls, ID); Henslee, S. Paul (Idaho Falls, ID)

2005-07-19T23:59:59.000Z

266

Vapor Pressures and Vaporization, Sublimation, and Fusion Enthalpies of Some Fatty Acids  

E-Print Network (OSTI)

Vapor Pressures and Vaporization, Sublimation, and Fusion Enthalpies of Some Fatty Acids Joe A. Wilson and James S. Chickos* Department of Chemistry and Biochemistry, University of MissouriSt. Louis, St. Louis, Missouri 63121, United States *S Supporting Information ABSTRACT: Sublimation enthalpies

Chickos, James S.

267

Vapor Pressures and Vaporization Enthalpies of a Series of Dialkyl Phthalates by Correlation Gas Chromatography  

E-Print Network (OSTI)

Chromatography Chase Gobble and James Chickos* Department of Chemistry and Biochemistry University of Missouri-St. Louis, St. Louis Missouri 63121, United States Sergey P. Verevkin Department of Physical Chemistry: Experimental vapor pressures, vaporization, fusion and sublimation enthalpies of a number of dialkyl

Chickos, James S.

268

Hydrogen embrittlement of type 410 stainless steel in sodium chloride, sodium sulfate, and sodium hydroxide environments at 90 C  

SciTech Connect

Susceptibility of martensitic type 410 (UNS S41000) stainless steel (SS) to environmental cracking was evaluated at 90 C in concentrated sodium chloride, sodium sulfate and sodium hydroxide solutions, all of which are environments related to steam turbine conditions, using the slow strain rate testing (SSRT) technique. In NaCl, the effects of solution pH, concentration, and anodic and cathodic polarization were investigated. Tests were supplemented by detailed electron fractography and hydrogen permeation measurements. A clear correlation was found between the degree of embrittlement and the amount of hydrogen permeating the steel, suggesting a hydrogen-induced cracking mechanism.

Gonzalez-Rodriguez, J.G.; Salinas-Bravo, V.M. [Inst. de Investigaciones Electricas, Cuernavaca (Mexico). Dept. Fisico Quimica Aplicada; Martinez-Villafane, A. [Centro de Investigaciones en Materiales Avanzados Leon Tolstoi, Chihuahua (Mexico)

1997-06-01T23:59:59.000Z

269

High-capacity hydrogen storage in lithium and sodium amidoboranes...  

NLE Websites -- All DOE Office Websites (Extended Search)

capacity hydrogen storage in lithium and sodium amidoboranes. High-capacity hydrogen storage in lithium and sodium amidoboranes. Abstract: A substantial effort worldwide has been...

270

Superfund record of decision (EPA Region 4): USDOE Oak Ridge Reservation, Lower Watts Bar Reservoir Operable Unit, Oak Ridge, TN, September 29, 1995  

SciTech Connect

The decision document presents the selected remedial action for the Lower Watts Bar Reservoir (LWBR) Operable Unit (OU). The selected remedy for the LWBR OU addresses the contamination of the Watts Bar Reservoir area from Tennessee River mile (TRM) 529.9 at Watts Bar Dam upstream to TRM 567.5 at the confluence of the Clinch and Tennessee Rivers. The response action was chosen from a full range of actions that could possibly address the two primary risks identified in the remedial investigation (RI). Risks to human health posed by LWBR include exposure to metals in deep sediment of the main river channel and to polychlorinated biphenyls (PCBs), chlordane, aldrin, arsenic, and mercury in fish tissue. The same response actions are applicable to reducing ecological risk in LWBR. The selected remedy uses existing institutional controls to reduce exposure to contaminated sediment; fish consumption advisories to reduce exposure to contaminants in fish tissue; and annual monitoring to detect changes in LWBR contaminant levels or mobility.

NONE

1996-02-01T23:59:59.000Z

271

IAEA sodium void reactivity benchmark calculations  

SciTech Connect

In this paper, the IAEA-1 992 ``Benchmark Calculation of Sodium Void Reactivity Effect in Fast Reactor Core`` problem is evaluated. The proposed design is a large axially heterogeneous oxide-fueled fast reactor as described in Section 2; the core utilizes a sodium plenum above the core to enhance leakage effects. The calculation methods used in this benchmark evaluation are described in Section 3. In Section 4, the calculated core performance results for the benchmark reactor model are presented; and in Section 5, the influence of steel and interstitial sodium heterogeneity effects is estimated.

Hill, R.N.; Finck, P.J.

1992-12-01T23:59:59.000Z

272

IAEA sodium void reactivity benchmark calculations  

SciTech Connect

In this paper, the IAEA-1 992 Benchmark Calculation of Sodium Void Reactivity Effect in Fast Reactor Core'' problem is evaluated. The proposed design is a large axially heterogeneous oxide-fueled fast reactor as described in Section 2; the core utilizes a sodium plenum above the core to enhance leakage effects. The calculation methods used in this benchmark evaluation are described in Section 3. In Section 4, the calculated core performance results for the benchmark reactor model are presented; and in Section 5, the influence of steel and interstitial sodium heterogeneity effects is estimated.

Hill, R.N.; Finck, P.J.

1992-01-01T23:59:59.000Z

273

ARM - Field Campaign - Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 1996.09.10 - 1996.09.30 Lead Scientist : Henry Revercomb For data sets, see below. Summary SCHEDULE This IOP will be conducted from September 10 - 30, 1996 (coincident with the Fall ARM-UAV IOP). Instruments that do not require supervision will be operated continuously during this period. Instruments that do require supervision are presently planned to be operated for 8-hour periods each day. Because it is necessary to cover as broad a range of environmental conditions as possible, the daily 8-hour period will be shifted across the diurnal cycle as deemed appropriate during the IOP (but will be maintained as a contiguous 8-hour block).

274

atmospheric water vapor | OpenEI  

Open Energy Info (EERE)

atmospheric water vapor atmospheric water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for 2-axis tracking concentrating collectors for Mexico, Central America, and the Caribbean Islands. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to a concentrating collector, such as a dish collector, which tracks the sun continuously. Source NREL Date Released July 31st, 2006 (8 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmospheric water vapor Carribean Islands Central America DNI GIS Mexico NREL GEF solar SWERA UNEP Data application/zip icon Download Shapefile (zip, 247.8 KiB) text/csv icon Download Data (csv, 370.6 KiB) Quality Metrics Level of Review Some Review

275

atmoshperic water vapor | OpenEI  

Open Energy Info (EERE)

atmoshperic water vapor atmoshperic water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for flat-plate collectors tilted at latitude for China. Source NREL Date Released April 12th, 2005 (9 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmoshperic water vapor China GEF GIS NREL solar SWERA TILT UNEP Data application/zip icon Download Shapefile (zip, 625.6 KiB) text/csv icon Download Data (csv, 704.1 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period 01/01/1985 - 12/31/1991 License License Open Data Commons Public Domain Dedication and Licence (PDDL) Comment Rate this dataset Usefulness of the metadata Average vote Your vote Usefulness of the dataset Average vote Your vote Ease of access

276

Vapor characterization of Tank 241-C-103  

SciTech Connect

The Westinghouse Hanford Company Tank Vapor Issue Resolution Program has developed, in cooperation with Northwest Instrument Systems, Inc., Oak Ridge National Laboratory, Oregon Graduate Institute of Science and Technology, Pacific Northwest Laboratory, and Sandia National Laboratory, the equipment and expertise to characterize gases and vapors in the high-level radioactive waste storage tanks at the Hanford Site in south central Washington State. This capability has been demonstrated by the characterization of the tank 241-C-103 headspace. This tank headspace is the first, and for many reasons is expected to be the most problematic, that will be characterized (Osborne 1992). Results from the most recent and comprehensive sampling event, sample job 7B, are presented for the purpose of providing scientific bases for resolution of vapor issues associated with tank 241-C-103. This report is based on the work of Clauss et al. 1994, Jenkins et al. 1994, Ligotke et al. 1994, Mahon et al. 1994, and Rasmussen and Einfeld 1994. No attempt has been made in this report to evaluate the implications of the data presented, such as the potential impact of headspace gases and vapors to tank farm workers health. That and other issues will be addressed elsewhere. Key to the resolution of worker health issues is the quantitation of compounds of toxicological concern. The Toxicology Review Panel, a panel of Pacific Northwest Laboratory experts in various areas, of toxicology, has chosen 19 previously identified compounds as being of potential toxicological concern. During sample job 7B, the sampling and analytical methodology was validated for this preliminary list of compounds of toxicological concern. Validation was performed according to guidance provided by the Tank Vapor Conference Committee, a group of analytical chemists from academic institutions and national laboratories assembled and commissioned by the Tank Vapor Issue Resolution Program.

Huckaby, J.L. [Westinghouse Hanford Co., Richland, WA (United States); Story, M.S. [Northwest Instrument Systems, Inc. Richland, WA (United States)

1994-06-01T23:59:59.000Z

277

Thermal electric vapor trap arrangement and method  

DOE Patents (OSTI)

A technique for trapping vapor within a section of a tube is disclosed herein. This technique utilizes a conventional, readily providable thermal electric device having a hot side and a cold side and means for powering the device to accomplish this. The cold side of this device is positioned sufficiently close to a predetermined section of the tube and is made sufficiently cold so that any condensable vapor passing through the predetermined tube section is condensed and trapped, preferably within the predetermined tube section itself. 4 figs.

Alger, T.

1988-03-15T23:59:59.000Z

278

Diode pumped alkali vapor fiber laser  

DOE Patents (OSTI)

A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.

Payne, Stephen A. (Castro Valley, CA); Beach, Raymond J. (Livermore, CA); Dawson, Jay W. (Livermore, CA); Krupke, William F. (Pleasanton, CA)

2006-07-26T23:59:59.000Z

279

Diode pumped alkali vapor fiber laser  

DOE Patents (OSTI)

A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.

Payne, Stephen A. (Castro Valley, CA); Beach, Raymond J. (Livermore, CA); Dawson, Jay W. (Livermore, CA); Krupke, William F. (Pleasanton, CA)

2007-10-23T23:59:59.000Z

280

Sodium Alanate Nanoparticles for Hydrogen Storage.  

E-Print Network (OSTI)

??Preparation and characterization of sodium alanate (NaAlH4) based hydrogen storage materials are described in this book. The effect of the NaAlH4 particle size, particularly in (more)

Bald, C.P.

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Watt steam governor  

Science Journals Connector (OSTI)

The physics of the fly-ball governor, introduced to regulate the speed of steam engines, is here analysed anew. The original analysis is generalized to arbitrary governor geometry. The well-known stability criterion for the linearized system breaks down for large excursions from equilibrium; we show approximately how this criterion changes.

Mark Denny

2002-01-01T23:59:59.000Z

282

Quanta vs. watts  

Science Journals Connector (OSTI)

power available. In plant groups other than phaeophytes neither quantum or energy measurements are entirely satisfactory. In green and red algae the quantum...

2000-01-03T23:59:59.000Z

283

James Watt and biotechnology  

Science Journals Connector (OSTI)

... be if universities were genuinely autonomous and not as at present constrained by an invidious numerus ...

1982-08-05T23:59:59.000Z

284

The Sodium Process Facility at Argonne National Laboratory-West  

SciTech Connect

Argonne National Laboratory-West (ANL-W) has approximately 680,000 liters of raw sodium stored in facilities on site. As mandated by the State of Idaho and the US Department of Energy (DOE), this sodium must be transformed into a stable condition for land disposal. To comply with this mandate, ANL-W designed and built the Sodium Process Facility (SPF) for the processing of this sodium into a dry, sodium carbonate powder. The major portion of the sodium stored at ANL-W is radioactively contaminated. The sodium will be processed in three separate and distinct campaigns: the 290,000 liters of Fermi-1 primary sodium, the 50,000 liters of the Experimental Breeder Reactor-II (EBR-II) secondary sodium, and the 330,000 liters of the EBR-II primary sodium. The Fermi-1 and the EBR-II secondary sodium contain only low-level of radiation, while the EBR-II primary sodium has radiation levels up to 0.5 mSv (50 mrem) per hour at 1 meter. The EBR-II primary sodium will be processed last, allowing the operating experience to be gained with the less radioactive sodium prior to reacting the most radioactive sodium. The sodium carbonate will be disposed of in 270 liter barrels, four to a pallet. These barrels are square in cross-section, allowing for maximum utilization of the space on a pallet, minimizing the required landfill space required for disposal.

Michelbacher, J.A.; Henslee, S.P. McDermott, M.D.; Price, J.R.; Rosenberg, K.E.; Wells, P.B.

1998-07-01T23:59:59.000Z

285

Environmental Chemistry at Vapor/Water Interfaces  

E-Print Network (OSTI)

Environmental Chemistry at Vapor/Water Interfaces: Insights from Vibrational Sum Frequency Generation Spectroscopy Aaron M. Jubb, Wei Hua, and Heather C. Allen Department of Chemistry, The Ohio State/0505-0107$20.00 Keywords salts, lipids, atmospheric chemistry, ion binding, oxidation Abstract The chemistry that occurs

286

Advancing Explosives Detection Capabilities: Vapor Detection  

ScienceCinema (OSTI)

A new, PNNL-developed method provides direct, real-time detection of trace amounts of explosives such as RDX, PETN and C-4. The method selectively ionizes a sample before passing the sample through a mass spectrometer to detect explosive vapors. The method could be used at airports to improve aviation security.

Atkinson, David

2014-07-24T23:59:59.000Z

287

Program performs vapor-liquid equilibrium calculations  

SciTech Connect

A program designed for the Hewlett-Packard HP-41CV or 41C calculators solves basic vapor-liquid equilibrium problems, including figuring the dewpoint, bubblepoint, and equilibrium flash. The algorithm uses W.C. Edmister's method for predicting ideal-solution K values.

Rice, V.L.

1982-06-28T23:59:59.000Z

288

Synchroton X-Ray Studies of Liquid-Vapor Interfaces  

Science Journals Connector (OSTI)

The variation of density across the liquid-vapor interface from essentially zero density far out in the vapor phase to a homogeneous density deep in the liquid phase can be determined by X-ray reflectivity mea...

J. Als-Nielsen

1988-01-01T23:59:59.000Z

289

Vapor intrusion modeling : limitations, improvements, and value of information analyses  

E-Print Network (OSTI)

Vapor intrusion is the migration of volatile organic compounds (VOCs) from a subsurface source into the indoor air of an overlying building. Vapor intrusion models, including the Johnson and Ettinger (J&E) model, can be ...

Friscia, Jessica M. (Jessica Marie)

2014-01-01T23:59:59.000Z

290

Estimating the Atmospheric Water Vapor Content from Sun Photometer Measurements  

Science Journals Connector (OSTI)

The differential absorption technique for estimating columnar water vapor values from the analysis of sunphotometric measurements with wide- and narrowband interferential filters centered near 0.94 ?m is discussed and adapted. Water vapor line ...

Artemio Plana-Fattori; Michel Legrand; Didier Tanr; Claude Devaux; Anne Vermeulen; Philippe Dubuisson

1998-08-01T23:59:59.000Z

291

OPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL  

E-Print Network (OSTI)

given by U.S. Department of Energy, Geothermal Division. #12;vii Table of Contents ABSTRACTOPTIMIZATION OF INJECTION INTO VAPOR-DOMINATED GEOTHERMAL RESERVOIRS CONSIDERING ADSORPTION governing the behavior of vapor- dominated geothermal reservoirs. These mechanisms affect both

Stanford University

292

Apparent Temperature Dependence on Localized Atmospheric Water Vapor  

E-Print Network (OSTI)

Apparent Temperature Dependence on Localized Atmospheric Water Vapor Matthew Montanaroa, Carl), hence water vapor is the primary constituent of concern. The tower generates a localized water vapor, Office B108, Aiken, SC, USA ABSTRACT The atmosphere is a critical factor in remote sensing. Radiance from

Salvaggio, Carl

293

Advanced Membrane Systems: Recovering Wasteful and Hazardous Fuel Vapors at the Gasoline Tank  

Energy.gov (U.S. Department of Energy (DOE))

Case study covering Compact Membrane Systems, Inc. and its membrane vapor processor that recovers fuel vapors from gasoline refueling.

294

Design, fabrication, and testing of a sodium evaporator for the STM4-120 kinematic Stirling engine  

SciTech Connect

This report describes the development and testing of a compact heat-pipe heat exchanger kW(e) designed to transfer thermal energy from hot combustion gases to the heater tubes of a 25-kW(e) Stirling engine. In this system, sodium evaporates from a surface that is heated by a stream of hot gases. The liquid metal then condenses on the heater tubes of a Stirling engine, where energy is transferred to the engine`s helium working fluid. Tests on a prototype unit illustrated that a compact (8 cm {times} 13 cm {times} 16 cm) sodium evaporator can routinely transfer 15 kW(t) of energy at an operating vapor temperature of 760 C. Four of these prototype units were eventually used to power a 25-kW(e) Stirling engine system. Design details and test results from the prototype unit are presented in this report.

Rawlinson, K.S.; Adkins, D.R.

1995-05-01T23:59:59.000Z

295

Precision micro drilling with copper vapor lasers  

SciTech Connect

The authors have developed a copper vapor laser based micro machining system using advanced beam quality control and precision wavefront tilting technologies. Micro drilling has been demonstrated through percussion drilling and trepanning using this system. With a 30 W copper vapor laser running at multi-kHz pulse repetition frequency, straight parallel holes with size varying from 500 microns to less than 25 microns and with aspect ratio up to 1:40 have been consistently drilled on a variety of metals with good quality. For precision trepanned holes, the hole-to-hole size variation is typically within 1% of its diameter. Hole entrance and exit are both well defined with dimension error less than a few microns. Materialography of sectioned holes shows little (sub-micron scale) recast layer and heat affected zone with surface roughness within 1--2 microns.

Chang, J.J.; Martinez, M.W.; Warner, B.E.; Dragon, E.P.; Huete, G.; Solarski, M.E.

1994-09-02T23:59:59.000Z

296

Copper vapor laser modular packaging assembly  

DOE Patents (OSTI)

A modularized packaging arrangement for one or more copper vapor lasers and associated equipment is disclosed herein. This arrangement includes a single housing which contains the laser or lasers and all their associated equipment except power, water and neon, and means for bringing power, water, and neon which are necessary to the operation of the lasers into the container for use by the laser or lasers and their associated equipment.

Alger, Terry W. (Tracy, CA); Ault, Earl R. (Dublin, CA); Moses, Edward I. (Castro Valley, CA)

1992-01-01T23:59:59.000Z

297

A High Temperature Electrochemical Energy Storage System Based on Sodium Beta-Alumina Solid Electrolyte (Base)  

SciTech Connect

This report summarizes the work done during the period September 1, 2005 and March 31, 2008. Work was conducted in the following areas: (1) Fabrication of sodium beta{double_prime} alumina solid electrolyte (BASE) using a vapor phase process. (2) Mechanistic studies on the conversion of {alpha}-alumina + zirconia into beta{double_prime}-alumina + zirconia by the vapor phase process. (3) Characterization of BASE by X-ray diffraction, SEM, and conductivity measurements. (4) Design, construction and electrochemical testing of a symmetric cell containing BASE as the electrolyte and NaCl + ZnCl{sub 2} as the electrodes. (5) Design, construction, and electrochemical evaluation of Na/BASE/ZnCl{sub 2} electrochemical cells. (6) Stability studies in ZnCl{sub 2}, SnCl{sub 2}, and SnI{sub 4} (7) Design, assembly and testing of planar stacks. (8) Investigation of the effect of porous surface layers on BASE on cell resistance. The conventional process for the fabrication of sodium ion conducting beta{double_prime}-alumina involves calcination of {alpha}-alumina + Na{sub 2}CO{sub 3} + LiNO{sub 3} at 1250 C, followed by sintering powder compacts in sealed containers (platinum or MgO) at {approx}1600 C. The novel vapor phase process involves first sintering a mixture of {alpha}-alumina + yttria-stabilized zirconia (YSZ) into a dense ceramic followed by exposure to soda vapor at {approx}1450 C to convert {alpha}-alumina into beta{double_prime}-alumina. The vapor phase process leads to a high strength BASE, which is also resistant to moisture attack, unlike BASE made by the conventional process. The PI is the lead inventor of the process. Discs and tubes of BASE were fabricated in the present work. In the conventional process, sintering of BASE is accomplished by a transient liquid phase mechanism wherein the liquid phase contains NaAlO{sub 2}. Some NaAlO{sub 2} continues to remain at grain boundaries; and is the root cause of its water sensitivity. In the vapor phase process, NaAlO{sub 2} is never formed. Conversion occurs by a coupled transport of Na{sup +} through BASE formed and of O{sup 2-} through YSZ to the reaction front. Transport to the reaction front is described in terms of a chemical diffusion coefficient of Na{sub 2}O. The conversion kinetics as a function of microstructure is under investigation. The mechanism of conversion is described in this report. A number of discs and tubes of BASE have been fabricated by the vapor phase process. The material was investigated by X-ray diffraction (XRD), optical microscopy and scanning electron microscopy (SEM), before and after conversion. Conductivity (which is almost exclusively due to sodium ion transport at the temperatures of interest) was measured. Conductivity was measured using sodium-sodium tests as well as by impedance spectroscopy. Various types of both planar and tubular electrochemical cells were assembled and tested. In some cases the objective was to determine if there was any interaction between the salt and BASE. The interaction of interest was mainly ion exchange (possible replacement of sodium ion by the salt cation). It was noted that Zn{sup 2+} did not replace Na+ over the conditions of interest. For this reason much of the work was conducted with ZnCl{sub 2} as the cathode salt. In the case of Sn-based, Sn{sup 2+} did ion exchange, but Sn{sup 4+} did not. This suggests that Sn{sup 4+} salts are viable candidates. These results and implications are discussed in the report. Cells made with Na as the anode and ZnCl{sub 2} as the cathode were successfully charged/discharged numerous times. The key advantages of the batteries under investigation here over the Na-S batteries are: (1) Steel wool can be used in the cathode compartment unlike Na-S batteries which require expensive graphite. (2) Planar cells can be constructed in addition to tubular, allowing for greater design flexibility and integration with other devices such as planar SOFC. (3) Comparable or higher open circuit voltage (OCV) than the Na-S battery. (4) Wider operating temperature range and higher temper

Anil Virkar

2008-03-31T23:59:59.000Z

298

Safety Evaluation Report related to the operation of Watts Bar Nuclear Plant, Units 1 and 2 (Docket Numbers 50-390 and 50-391). Supplement Number 13  

SciTech Connect

This report supplements the Safety Evaluation Report (SER), NUREG-0847 (June 1982), Supplement No. 1 (September 1982), Supplement No. 2 (January 1984), Supplement No. 3 (January 1985), Supplement No. 4 (March 1985), Supplement No. 5 (November 1990), Supplement No. 6 (April 1991), Supplement No. 7 (September 1991), Supplement No. 8 (January 1992), Supplement No. 9 (June 1992), Supplement No. 10 (October 1992), Supplement No. 11 (April 1993), and Supplement No. 12 (October 1993), issued by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission with respect to the application filed by the Tennessee Valley Authority, as applicant and owner, for licenses to operate the Watts Bar Nuclear Plant, Units 1 and 2 (Docket Nos. 50-390 and 50-391). The facility is located in Rhea County, Tennessee, near the Watts Bar Dam on the Tennessee River. This supplement provides recent information regarding resolution of some of the outstanding and confirmatory items, and proposed license conditions identified in the SER. These issues relate to: Design criteria -- structures, components, equipment, and systems; Reactor; Instrumentation and controls; Electrical power systems; Auxiliary systems; Conduct of operations; Accident analysis; and Quality assurance.

Not Available

1994-04-01T23:59:59.000Z

299

Village of Endicott, New York (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Village of Endicott Village of Endicott Place New York Utility Id 5875 Utility Location Yes Ownership M NERC Location NPCC NERC NPCC Yes ISO NY Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial, Professional and Small Power Installs Commercial Large Power and Light Installations Commercial Residential and Religious Customers Residential Security Lighting (100 Watt Glow) Lighting Security Lighting (175 Watt Mercury Vapor) Commercial Security Lighting (400 Watt Mercury Vapor) Commercial Security Lighting (400 Watt Sodium) Commercial

300

Jo-Carroll Energy Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Jo-Carroll Energy Coop Inc Jo-Carroll Energy Coop Inc Jump to: navigation, search Name Jo-Carroll Energy Coop Inc Place Illinois Utility Id 9750 Utility Location Yes Ownership C NERC Location MRO NERC MRO Yes ISO MISO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Area Lighting Rate(100 Watts Sodium Vapor) Lighting Area Lighting Rate(175 Watts Mercury Vapor) Lighting Area Lighting Rate(250 Watts) Lighting Area Lighting Rate(400 Watts) Lighting Coincident Peak Service(OPTIONAL) Commercial Dual Fuel - A Commercial Electric Large General Service Commercial Electric Large General Service Time-of-day use Commercial

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

City of Lexington, Tennessee (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Tennessee (Utility Company) Tennessee (Utility Company) Jump to: navigation, search Name City of Lexington Place Tennessee Utility Id 10968 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Area Lighting Metal service(175 Watt Mercury Vapor) Lighting Area Lighting Service(100 Watt High Pressure Sodium) Lighting Area Lighting Service(400 Watt Metal Halide Shoe-Box Single) Lighting Area Lighting Service(400 Watt Metal Halide Shoe-Box Twin) Lighting Area Lighting service(100 Watt Decorative Acorn) Lighting

302

Reaction of Sodium Borohydride with Wool  

Science Journals Connector (OSTI)

... It has recently been found that sodium borohydride in alkaline solution rapidly dissolves wool under conditions of temperature and pH milder than many in current use. The reaction ... in current use. The reaction has been studied as follows: 1 gm. of solvent-scoured Merino ...

J. M. GILLESPIE

1959-01-31T23:59:59.000Z

303

In sodium tests of ultrasonic transducers  

SciTech Connect

Ultrasonic techniques are seen as suitable candidates for the in-service inspection and for the continuous surveillance of sodium cooled reactors (SFR). These techniques need the development and the qualification of immersed ultrasonic transducers, and materials. This paper presents some developments performed by CEA (DTN and LIST) and AREVA (NDE Solutions), and some results. (authors)

Lhuillier, C.; Descombin, O.; Baque, F. [CEA, DTN, 13108 Saint Paul lez Durance Cedex (France); Marchand, B. [CEA, LIST, 91191 Gif-sur-Yvette (France); Saillant, J. F. [AREVA/NDE Solutions, 4 rue Thomas Dumorey, 71109 Chalon sur Saone Cedex (France); Augem, J. M. [EDF, 12-14 avenue Dutrievoz, 69628 Villeurbanne (France)

2011-07-01T23:59:59.000Z

304

Inhibition Of Washed Sludge With Sodium Nitrite  

SciTech Connect

This report describes the results of electrochemical tests used to determine the relationship between the concentration of the aggressive anions in washed sludge and the minimum effective inhibitor concentration. Sodium nitrate was added as the inhibitor because of its compatibility with the DWPF process. A minimum of 0.05M nitrite is required to inhibit the washed sludge simulant solution used in this study. When the worst case compositions and safety margins are considered, it is expected that a minimum operating limit of nearly 0.1M nitrite will be specified. The validity of this limit is dependent on the accuracy of the concentrations and solubility splits previously reported. Sodium nitrite additions to obtain 0.1M nitrite concentrations in washed sludge will necessitate the additional washing of washed precipitate in order to decrease its sodium nitrite inhibitor requirements sufficiently to remain below the sodium limits in the feed to the DWPF. Nitrite will be the controlling anion in "fresh" washed sludge unless the soluble chloride concentration is about ten times higher than predicted by the solubility splits. Inhibition of "aged" washed sludge will not be a problem unless significant chloride dissolution occurs during storage. It will be very important tomonitor the composition of washed sludge during processing and storage.

Congdon, J. W.; Lozier, J. S.

2012-09-25T23:59:59.000Z

305

Central Texas Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Elec Coop, Inc Elec Coop, Inc Place Texas Utility Id 3282 Utility Location Yes Ownership C NERC Location TRE NERC ERCOT Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rate Schedule Commercial General Service Residential Irrigation and Large Pumping Rate Schedule Commercial Large Power Schedule Industrial Security Lights(100 Watt High Pressure Sodium) Lighting Security Lights(175 Watt Mercury Vapor ) Lighting Security Lights(250 Watt High Pressure Sodium) Lighting Security Lights(250 Watt Metal Halide (Special Application Only) Lighting

306

Gypsum and Polyacrylamide Soil Amendments Used With High Sodium Wastewater  

E-Print Network (OSTI)

Using wastewater for irrigation of crops represents an attractive alternative to disposal. Typically, municipal wastewaters are high in sodium, and the resulting high sodium absorption ratio (SAR) alters the soil structure making it more impermeable...

Gardiner, Duane

307

ARM - Field Campaign - Fall 1997 Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Vapor IOP Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Fall 1997 Water Vapor IOP 1997.09.15 - 1997.10.05 Lead Scientist : Henry Revercomb For data sets, see below. Summary The Water Vapor IOP was conducted as a follow-up to a predecessor IOP on water vapor held in September 1996. This IOP relied heavily on both ground-based guest and CART instrumentation and in-situ aircraft and tethered sonde/kite measurements. Primary operational hours were from 6 p.m. Central until at least midnight, with aircraft support normally from about 9 p.m. until midnight when available. However, many daytime measurements were made to support this IOP. The first Water Vapor IOP primarily concentrated on the atmosphere's lowest

308

G-Band Vapor Radiometer Profiler (GVRP) Handbook  

SciTech Connect

The G-Band Vapor Radiometer Profiler (GVRP) provides time-series measurements of brightness temperatures from 15 channels between 170 and 183.310 GHz. Atmospheric emission in this spectral region is primarily due to water vapor, with some influence from liquid water. Channels between 170.0 and 176.0 GHz are particularly sensitive to the presence of liquid water. The sensitivity to water vapor of the 183.31-GHz line is approximately 30 times higher than at the frequencies of the two-channel microwave radiometer (MWR) for a precipitable water vapor (PWV) amount of less than 2.5 mm. Measurements from the GVRP instrument are therefore especially useful during low-humidity conditions (PWV < 5 mm). In addition to integrated water vapor and liquid water, the GVRP can provide low-resolution vertical profiles of water vapor in very dry conditions.

Caddeau, MP

2010-06-23T23:59:59.000Z

309

Vapor port and groundwater sampling well  

DOE Patents (OSTI)

A method and apparatus has been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing.

Hubbell, Joel M. (Idaho Falls, ID); Wylie, Allan H. (Idaho Falls, ID)

1996-01-01T23:59:59.000Z

310

Chemical vapor deposition of epitaxial silicon  

DOE Patents (OSTI)

A single chamber continuous chemical vapor deposition (CVD) reactor is described for depositing continuously on flat substrates, for example, epitaxial layers of semiconductor materials. The single chamber reactor is formed into three separate zones by baffles or tubes carrying chemical source material and a carrier gas in one gas stream and hydrogen gas in the other stream without interaction while the wafers are heated to deposition temperature. Diffusion of the two gas streams on heated wafers effects the epitaxial deposition in the intermediate zone and the wafers are cooled in the final zone by coolant gases. A CVD reactor for batch processing is also described embodying the deposition principles of the continuous reactor.

Berkman, Samuel (Florham Park, NJ)

1984-01-01T23:59:59.000Z

311

Storing images in warm atomic vapor  

E-Print Network (OSTI)

Reversible and coherent storage of light in atomic medium is a key-stone of future quantum information applications. In this work, arbitrary two-dimensional images are slowed and stored in warm atomic vapor for up to 30 $\\mu$s, utilizing electromagnetically induced transparency. Both the intensity and the phase patterns of the optical field are maintained. The main limitation on the storage resolution and duration is found to be the diffusion of atoms. A techniqueanalogous to phase-shift lithography is employed to diminish the effect of diffusion on the visibility of the reconstructed image.

M. Shuker; O. Firstenberg; R. Pugatch; A. Ron; N. Davidson

2008-06-17T23:59:59.000Z

312

PUD No 1 of Cowlitz County | Open Energy Information  

Open Energy Info (EERE)

Cowlitz County Cowlitz County Jump to: navigation, search Name PUD No 1 of Cowlitz County Place Washington Utility Id 4442 Utility Location Yes Ownership P NERC Location WECC NERC WECC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png DIRECT ACCESS DELIVERY CHARGE TRANSMISSION VOLTAGE DELIVERY SCHEDULE 62 Commercial GENERAL SERVICE SCHEDULE 5 Industrial PRIVATE STREET AND AREA LIGHTING SCHEDULE 10 Sodium Vapor 100 watts Lighting PRIVATE STREET AND AREA LIGHTING SCHEDULE 10 Sodium Vapor 200 watts Lighting PUBLIC STREET LIGHTING SERVICE SCHEDULE 40 - HPS 100 Watt Lighting

313

Recovery of benzene in an organic vapor monitor  

E-Print Network (OSTI)

solid adsorbents available (silica gel, activated alumina, etc. ), activated charcoal is most frequently utilized. Activated charcoal has retentivity for sorbed vapors several times that of silica gel and it displays a selectivity for organic vapors... (diffusion rate) of the vapor molecules to the sur- face of the adsorbent. The adsorption process determine how effective the adsorbent collects and holds the contam- inant on the surface of the activated charcoal. Recovery of the contaminant from...

Krenek, Gregory Joel

2012-06-07T23:59:59.000Z

314

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Exploration Activity Details Location Haleakala Volcano Area Exploration Technique Mercury Vapor Activity Date Usefulness not indicated DOE-funding Unknown Notes The field survey program on the northwest rift zone consisted of soil mercury and radon emanometry surveys, groundwater temperature and chemistry studies, Schlumberger resistivity soundings and self-potential profiles. Geophysical and geochemical surveys along this rift (southwest) were limited by difficult field conditions and access limitations. The geophysical program consisted of one Schlumberger sounding, one

315

Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity Details...

316

Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity...

317

Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck,...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity...

318

Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) ...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) Exploration Activity Details...

319

Mercury Vapor At Socorro Mountain Area (Kooten, 1987) | Open...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Socorro Mountain Area (Kooten, 1987) Exploration Activity Details Location...

320

Mercury Vapor At Lassen Volcanic National Park Area (Varekamp...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Lassen Volcanic National Park Area (Varekamp & Buseck, 1983) Exploration...

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Thermal Performance of a Double-Tube Type Lng Vaporizer  

Science Journals Connector (OSTI)

This report concerns the confirmed test results and method of analysis of the thermal performance of a double-tube type LNG vaporizer (DTV). The DTV is a...

Y. Miyata; T. Miura; S. Kasahara; H. Shohtani

1994-01-01T23:59:59.000Z

322

Optimal Control of Vapor Extraction of Heavy Oil.  

E-Print Network (OSTI)

??Vapor extraction (Vapex) process is an emerging technology for viscous oil recovery that has gained much attention in the oil industry. However, the oil production (more)

Muhamad, Hameed (Author)

2012-01-01T23:59:59.000Z

323

Geographic Information System At Cove Fort Area - Vapor (Nash...  

Open Energy Info (EERE)

navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geographic Information System At Cove Fort Area - Vapor (Nash, Et Al., 2002) Exploration Activity Details...

324

Raman Lidar Measurements of Aerosols and Water Vapor During the...  

NLE Websites -- All DOE Office Websites (Extended Search)

modifications reduced but could not eliminate these adverse effects. The Raman lidar water vapor (aerosol extinction) measurements produced by these modified algorithms were,...

325

Thermal Gradient Holes At Cove Fort Area - Vapor (Warpinski,...  

Open Energy Info (EERE)

Warpinski, Et Al., 2004) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Thermal Gradient Holes At Cove Fort Area - Vapor (Warpinski, Et Al.,...

326

Ground Magnetics At Cove Fort Area - Vapor (Warpinski, Et Al...  

Open Energy Info (EERE)

Vapor (Warpinski, Et Al., 2004) Exploration Activity Details Location Cove Fort Geothermal Area Exploration Technique Ground Magnetics Activity Date Usefulness useful DOE-funding...

327

Spray structures and vaporizing characteristics of a GDI fuel spray  

Science Journals Connector (OSTI)

The spray structures and distribution characteristics of liquid and vapor phases in non-evaporating and evaporating Gasoline Direct Injection (GDI) fuel sprays were investigated using Laser Induced...

Dong-Seok Choi; Gyung-Min Choi; Duck-Jool Kim

2002-07-01T23:59:59.000Z

328

Cast Stone Formulation At Higher Sodium Concentrations  

SciTech Connect

A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, including production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leachability indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the l

Fox, K. M.; Roberts, K. A.; Edwards, T. B.

2014-02-28T23:59:59.000Z

329

Breakup of Ring Beams Carrying Orbital Angular Momentum in Sodium Vapor Matthew S. Bigelow, Petros Zerom, and Robert W. Boyd  

E-Print Network (OSTI)

Zerom, and Robert W. Boyd The Institute of Optics, University of Rochester, Rochester, New York 14627

Boyd, Robert W.

330

Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates  

NLE Websites -- All DOE Office Websites (Extended Search)

Integration of Global Positioning System and Scanning Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates V. Mattioli and P. Basili Department of Electronic and Information Engineering University of Perugia Perugia, Italy E. R. Westwater Cooperative Institute for Research in Environmental Sciences University of Colorado National Oceanic and Atmospheric Administration Environmental Technology Laboratory Boulder, Colorado Introduction In recent years the Global Positioning System (GPS) has proved to be a reliable instrument for measuring precipitable water vapor (PWV) (Bevis et al. 1992), offering an independent source of information on water vapor when compared with microwave radiometers (MWRs), and/or radiosonde

331

Vapor and gas sampling of Single-Shell Tank 241-T-111 using the vapor sampling system  

SciTech Connect

This document presents sampling data resulting from the January 20, 1995, sampling of SST 241-T-111 using the vapor sampling system.

Caprio, G.S.

1995-09-01T23:59:59.000Z

332

Vapor and gas sampling of single-shell tank 241-BY-112 using the vapor sampling system  

SciTech Connect

This document presents sampling data from the November 18, 1994, sampling of SST 241-BY-112 using the vapor sampling system.

Caprio, G.S.

1995-09-20T23:59:59.000Z

333

Filtration of Sludge and Sodium Nonatitanate Solutions  

SciTech Connect

The proposed facility designs for the ion exchange and solvent extraction flowsheets under development to treat high level waste at the Savannah River Site use crossflow filtration to remove entrained sludge and monosodium titanate (MST). Bench-scale and pilot-scale testing performed with simulated feed streams showed much lower filtration rates than desired for the process. This report documents an investigation of the impact on filtration of using Honeywell sodium nonatitanate (ST), rather than MST, for strontium and actinide removal.

Poirier, M.R.

2000-10-16T23:59:59.000Z

334

City of Auburn, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Auburn, Indiana (Utility Company) Auburn, Indiana (Utility Company) Jump to: navigation, search Name City of Auburn Place Auburn, Indiana Utility Id 994 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Auburn, IN Smart Grid Project was awarded $2,075,080 Recovery Act Funding with a total project value of $4,150,160. Utility Rate Schedules Grid-background.png Private Outdoor Lighting- 100 watt sodium vapor lamp Lighting Private Outdoor Lighting- 175 watt mercury vapor lamp Lighting Private Outdoor Lighting- 250 watt mercury vapor lamp Lighting

335

Sodium Plugging Test Loop - Nuclear Engineering Division (Argonne)  

NLE Websites -- All DOE Office Websites (Extended Search)

Sodium Plugging Test Loop Sodium Plugging Test Loop Sodium Plugging Test Loop Overview Other Facilities Work with Argonne Contact us For Employees Site Map Help Join us on Facebook Follow us on Twitter NE on Flickr Sodium Plugging Test Loop This experimental setup is part of the Global Nuclear Energy Partnership (GNEP) Advanced Fuel Cycle R&D work carried out at Argonne on advanced sodium component technology. Bookmark and Share For long range sodium technology research and development, employing supercritical CO2 Brayton cycle power conversion technology as an advanced balance of plant technology is being considered. The component that provides the interface between the sodium and supercritical CO2 is a compact heat exchanger known as a printed circuit heat exchanger (PCHE). This heat exchanger has very small coolant flow passages that may foul or

336

Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Obtains Patent for Nuclear Reactor Sodium Cleanup Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment March 28, 2013 - 12:00pm Addthis CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. Piping in the east boiler basement of the sodium processing building was color coded for easy identification. Orange indicates sodium and green identifies cooling water.

337

Low-Pressure Sodium Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics August 16, 2013 - 10:17am Addthis Low-pressure sodium lighting provides more energy-efficient outdoor lighting than high-intensity discharge lighting, but it has very poor color rendition. Typical applications include highway and security lighting, where color is not important. Low-pressure sodium lamps work somewhat like fluorescent lamps. Like high-intensity discharge lighting, low-pressure sodium lamps require up to 10 minutes to start and have to cool before they can restart. Therefore, they are most suitable for applications in which they stay on for hours at a time. They are not suitable for use with motion detectors. The chart below compares low-pressure sodium lamps and high-intensity

338

Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment March 28, 2013 - 12:00pm Addthis CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. Piping in the east boiler basement of the sodium processing building was color coded for easy identification. Orange indicates sodium and green identifies cooling water.

339

Informal Report . VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY-  

E-Print Network (OSTI)

I BNL- 62834 Informal Report . VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY-· [D VAPOR DETECTION OF TRAFFICKING OF CONTRABAND MONEY- A DISCUSSION OF TECHNICAL FEASIBILITY Concept MONEY --A DISCUSSION OF TECHNICAL FEASffiILITY Russell N. Dietz, Head Tracer Technology Center

340

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR  

E-Print Network (OSTI)

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR By SCOTT RUSSELL WAITUKAITIS A Thesis Submitted: #12;Abstract I describe a study of Faraday rotation in a hot lithium vapor. I begin by dis- cussing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.3 The Lithium Oven and Solenoid . . . . . . . . . . . . . . . . . 7 3 Theoretical Framework

Cronin, Alex D.

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Recent Sodium Technology Development for the Decommissioning of the Rapsodie and Superphenix Reactors and the Management of Sodium Wastes  

SciTech Connect

The Commissariat a l'Energie Atomique (CEA) has recently developed and/or conducted experiments on several processes in support of the decommissioning of two French liquid-metal fast reactors (LMFRs), Rapsodie and Superphenix, as well as on the treatment of CEA sodium wastes. CEA has demonstrated that it is possible to define appropriate and efficient processes to meet the different situations encountered in decommissioning LMFRs. Mechanical techniques derived from standard technologies have been successfully applied to fast reactor decommissioning to complete primary vessel draining from sodium. In addition, specific chemical processes have been developed to deal safely with metallic sodium reactivity. Sodium-contaminated equipment has been successfully cleaned by reacting sodium with water mist in an atmosphere with carbon dioxide to form inert sodium carbonate. Bulk sodium has been successfully converted into aqueous caustic soda by injection of liquid-metallic sodium into sodium hydroxide solution. Several processes were also defined to deal with specific sodium wastes. In all cases the principle is based on a sodium/water chemical reaction where the released hydrogen and heat are controlled. With the development of a wide variety of processes, all steps in the decommissioning of LMFRs are assumed to be now properly mastered.

Rodriguez, G.; Gastaldi, O.; Baque, F. [Commissariat a l'Energie Atomique Cadarache (France)

2005-04-15T23:59:59.000Z

342

FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS  

Office of Scientific and Technical Information (OSTI)

Bulletin 627 Bulletin 627 BUREAU o b MINES FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS By Michael G. Zabetakis DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency Thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement,

343

New Regenerative Cycle for Vapor Compression Refrigeration  

Office of Scientific and Technical Information (OSTI)

SCIENTIFIC REPORT SCIENTIFIC REPORT Title Page Project Title: New Regenerative Cycle for Vapor Compression Refrigeration DOE Award Number: DE-FG36-04GO14327 Document Title: Final Scientific Report Period Covered by Report: September 30, 2004 to September 30, 2005 Name and Address of Recipient Organization: Magnetic Development, Inc., 68 Winterhill Road, Madison, CT 06443, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Contact Information: Mark J. Bergander, Ph.D., P.E., Principal Investigator, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Project Objective (as stated in the proposal): The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient

344

Chemical vapor deposition of group IIIB metals  

DOE Patents (OSTI)

Coatings of Group IIIB metals and compounds thereof are formed by chemical vapor deposition, in which a heat decomposable organometallic compound of the formula given in the patent where M is a Group IIIB metal, such as lanthanum or yttrium and R is a lower alkyl or alkenyl radical containing from 2 to about 6 carbon atoms, with a heated substrate which is above the decomposition temperature of the organometallic compound. The pure metal is obtained when the compound of the formula 1 is the sole heat decomposable compound present and deposition is carried out under nonoxidizing conditions. Intermetallic compounds such as lanthanum telluride can be deposited from a lanthanum compound of formula 1 and a heat decomposable tellurium compound under nonoxidizing conditions.

Erbil, A.

1989-11-21T23:59:59.000Z

345

Photo-Electric Ionization of Caesium Vapor  

Science Journals Connector (OSTI)

Measurement of photo-electric ionization in gases.The current from a filament, normally limited by space change, is increased by the presence of positive ions. As shown by Kingdon this effect may be greatly magnified if a small cathode is practically enclosed by the anode so that the ions are imprisoned. This method was used for the detection of photo-electric ionization. Besides possessing extreme sensitivity it is unaffected by photo-electric emission from the electrodes.Photo-electric effect in caesium vapor.The change in thermionic current with the unresolved radiation from a mercury arc was measured as functions of the applied voltage, filament temperature, and vapor pressure. Then the photo-electric effect as a function of wave-length was studied using a monochromatic illuminator to disperse light from the arc or a Mazda lamp. The ionization per unit flux was found to increase with increasing wave-length to a sharp maximum at the limit 1s=3184A of the principal series, as is required by the Bohr theory. For longer wave-lengths the ionization decreased to about 10 percent at 3400A. Photo-excitation. The simple theory does not admit of ionization by wave-lengths greater than 3184A but the data are in qualitative agreement with the hypothesis that such radiation produces excited atoms which upon collision with other atoms acquire sufficient additional energy to become ionized. Hence, unlike an x-ray limit, the photo-ionization effect for a valence electron is not sharply discontinuous at the true threshold for direct ionization.Photo-ionization photometer and intensitometer. A tube of the type described, with suitable gases for the range of wave-length involved, may be used as a photometer or may be calibrated to measure intensity of radiation directly.

Paul D. Foote and F. L. Mohler

1925-08-01T23:59:59.000Z

346

Gas Separation Using Organic-Vapor-Resistent Membranes In Conjunctin With Organic-Vapor-Selective Membranes  

DOE Patents (OSTI)

A process for treating a gas mixture containing at least an organic compound gas or vapor and a second gas, such as natural gas, refinery off-gas or air. The process uses two sequential membrane separation steps, one using membrane selective for the organic compound over the second gas, the other selective for the second gas over the organic vapor. The second-gas-selective membranes use a selective layer made from a polymer having repeating units of a fluorinated polymer, and demonstrate good resistance to plasticization by the organic components in the gas mixture under treatment, and good recovery after exposure to liquid aromatic hydrocarbons. The membrane steps can be combined in either order.

Baker, Richard W. (Palo Alto, CA); Pinnau, Ingo (Palo Alto, CA); He, Zhenjie (Fremont, CA); Da Costa, Andre R. (Menlo Park, CA); Daniels, Ramin (San Jose, CA); Amo, Karl D. (Mountain View, CA); Wijmans, Johannes G. (Menlo Park, CA)

2003-06-03T23:59:59.000Z

347

Hybrid Vapor Compression Adsorption System: Thermal Storage Using Hybrid Vapor Compression Adsorption System  

SciTech Connect

HEATS Project: UTRC is developing a new climate-control system for EVs that uses a hybrid vapor compression adsorption system with thermal energy storage. The targeted, closed system will use energy during the battery-charging step to recharge the thermal storage, and it will use minimal power to provide cooling or heating to the cabin during a drive cycle. The team will use a unique approach of absorbing a refrigerant on a metal salt, which will create a lightweight, high-energy-density refrigerant. This unique working pair can operate indefinitely as a traditional vapor compression heat pump using electrical energy, if desired. The project will deliver a hot-and-cold battery that provides comfort to the passengers using minimal power, substantially extending the driving range of EVs.

None

2012-01-04T23:59:59.000Z

348

Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems  

E-Print Network (OSTI)

engineer, improved upon the steam engine then patented theBoulton and Watt steam engine in 1775 [6]. Since then thean atmospheric heat engine that used steam) was developed by

Ho, Tony

2012-01-01T23:59:59.000Z

349

Factors contributing to the breakdown of sodium beta-alumina  

SciTech Connect

Clarification of the breakdown process occurring during charge transfer in sodium beta alumina solid electrolytes was derived from: (1) studying the effects of molten sodium contact at 350/sup 0/C on single crystal sodium beta alumina and polycrystalline sodium beta alumina; (2) determination of critical current density by monitoring acoustic emissions accompanying crack growth in sodium/sodium beta alumina/sodium cells subjected to linear current ramping at 1 mA cm/sup -2/ sec/sup -1/; (3) failure analysis conducted on cycled electrolytes, some from commercial sodium/sulfur cells, which had been subjected to up to 703 Ahr cm/sup -2/ of charge transfer. Gray coloration developing in beta aluminas in contact with molten sodium was found to be a consequence of formation, through reduction by sodium, of oxygen vacancies charge compensated by electrons. Electronic conductivity of the electrolyte increases as a result. No second phase formation was detected. Colored electrolytes from sodium/sulfur cells show evidence of a newly recognized degradation mechanism in which fracture occurs when sodium is reduced and deposited internally under pressure as metal in regions where an electronic conductivity gradient exists. Heating colored beta aluminas in air produces reoxidation and bleaching. Kinetics and other properties of the coloration and bleaching processes were determined. Critical current density was found to bear an inverse relation to average electrolyte grain size. Evidence was found in the cycled electrolytes for a slow crack growth mechanism and a progressive mode of degradation advancing from the sulfur electrode interface. Implications of the findings for the construction and operation of sodium/sulfur battery systems are discussed.

Buechele, A.C.

1982-05-01T23:59:59.000Z

350

E-Print Network 3.0 - atomic vapor laser Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

with the exception of pagination. IEEE TRANSACTIONS ON PLASMA SCIENCE 1 Summary: vapor, atomic physics and vapor ionization, absorption reflection in a heated plasma layer, and...

351

E-Print Network 3.0 - atom vapor cells Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

rotation in the vapor cell due to inten- sity-induced birefringence in the rubidium atomic vapor. While... Super efficient absorption filter for quantum memory using atomic...

352

Fact Sheet: Sodium-Beta Batteries (October 2012)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sodium-Beta Batteries Sodium-Beta Batteries Improving the performance and reducing the cost of sodium-beta batteries for large-scale energy storage Sodium-beta batteries (Na-beta batteries or NBBs) use a solid beta-alumina (ß˝-Al 2 O 3 ) electrolyte membrane that selectively allows sodium ion transport between a positive electrode (e.g., a metal halide) and a negative sodium electrode. NBBs typically operate at temperatures near 350˚C. They are increasingly used in renewable storage and utility applications due to their high round-trip efficiency, high energy densities, and energy storage capacities ranging from a few kilowatt-hours to multiple megawatt-hours. In fact, U.S. utilities

353

Sodium/Phosphorus-Sulfur Cells II. Phase Equilibria  

NLE Websites -- All DOE Office Websites (Extended Search)

II. Phase Equilibria II. Phase Equilibria Title Sodium/Phosphorus-Sulfur Cells II. Phase Equilibria Publication Type Journal Article Year of Publication 1996 Authors Ridgway, Paul L., Frank R. McLarnon, and John S. Newman Journal Journal of the Electrochemistry Society Volume 143 Issue 2 Pagination 412-417 Keywords 25 ENERGY STORAGE, 36 MATERIALS SCIENCE, ALUMINIUM OXIDES, equilibrium, performance, PHASE DIAGRAMS, PHOSPHIDES, PHOSPHORUS ADDITIONS, SODIUM COMPOUNDS, SODIUM SULFIDES, SODIUM-SULFUR BATTERIES Abstract Equilibrium open-circuit cell voltage data from a sodium/{beta}{double_prime}-alumina/phosphorus-sulfur cell utilizing P/S ratios of 0, 0.143, and 0.332 and a sodium atom fraction ranging from 0 to 0.4 were interpreted to construct ternary phase diagrams of the Na-P-S ternary system at 350 and 400 C.

354

Review of Chemical Processes for the Synthesis of Sodium Borohydride  

NLE Websites -- All DOE Office Websites (Extended Search)

Review of Chemical Processes for the Synthesis of Sodium Borohydride Review of Chemical Processes for the Synthesis of Sodium Borohydride Millennium Cell Inc. Prepared by Ying Wu Michael T. Kelly Jeffrey V. Ortega Under DOE Cooperative Agreement DE-FC36-04GO14008 August 2004 Table of Contents Introduction..................................................................................................................................... 1 Section 1: Commercially Practiced Sodium Borohydride Synthesis Process ............................... 2 The Brown-Schlesinger Process ................................................................................................. 2 The Bayer Process.......................................................................................................................

355

Data:99760b7a-6540-4145-ad9c-c25af6a93a26 | Open Energy Information  

Open Energy Info (EERE)

Incorporated (Alabama) Effective date: 20110319 End date if known: Rate name: 400 Watt Watt Mercury Vapor Sector: Lighting Description: Source or reference: https:...

356

Sodium cobalt bronze batteries and a method for making same  

DOE Patents (OSTI)

A solid state secondary battery utilizing a low cost, environmentally sound, sodium cobalt bronze electrode. A method is provided for producing same.

Doeff, Marca M. (Hayward, CA); Ma, Yanping (Berkeley, CA); Visco, Steven J. (Berkeley, CA); DeJonghe, Lutgard (Lafayette, CA)

1999-01-01T23:59:59.000Z

357

Internal temperatures of neutral sodium clusters: a PIE-thermometer  

Science Journals Connector (OSTI)

Distinct temperature effects could be observed in the threshold regions of photoionisation efficiency (PIE) measurements of sodium clusters. Simulations of the PIE thresholds at various temperatures were carried ...

U. Rthlisberger; M. Schr; E. Schumacher

1989-01-01T23:59:59.000Z

358

Preliminary assessment of halogenated alkanes as vapor-phase tracers  

SciTech Connect

New tracers are needed to evaluate the efficiency of injection strategies in vapor-dominated environments. One group of compounds that seems to meet the requirements for vapor-phase tracing are the halogenated alkanes (HCFCs). HCFCs are generally nontoxic, and extrapolation of tabulated thermodynamic data indicate that they will be thermally stable and nonreactive in a geothermal environment. The solubilities and stabilities of these compounds, which form several homologous series, vary according to the substituent ratios of fluorine, chlorine, and hydrogen. Laboratory and field tests that will further define the suitability of HCFCs as vapor-phase tracers are under way.

Adams, Michael C.; Moore, Joseph N.; Hirtz, Paul

1991-01-01T23:59:59.000Z

359

Mercury Vapor At Medicine Lake Area (Kooten, 1987) | Open Energy  

Open Energy Info (EERE)

Kooten, 1987) Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Medicine Lake Area (Kooten, 1987) Exploration Activity Details Location Medicine Lake Area Exploration Technique Mercury Vapor Activity Date Usefulness could be useful with more improvements DOE-funding Unknown References Gerald K. Van Kooten (1987) Geothermal Exploration Using Surface Mercury Geochemistry Retrieved from "http://en.openei.org/w/index.php?title=Mercury_Vapor_At_Medicine_Lake_Area_(Kooten,_1987)&oldid=386431" Category: Exploration Activities What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

360

Catalytic Reactor For Oxidizing Mercury Vapor  

DOE Patents (OSTI)

A catalytic reactor (10) for oxidizing elemental mercury contained in flue gas is provided. The catalyst reactor (10) comprises within a flue gas conduit a perforated corona discharge plate (30a, b) having a plurality of through openings (33) and a plurality of projecting corona discharge electrodes (31); a perforated electrode plate (40a, b, c) having a plurality of through openings (43) axially aligned with the through openings (33) of the perforated corona discharge plate (30a, b) displaced from and opposing the tips of the corona discharge electrodes (31); and a catalyst member (60a, b, c, d) overlaying that face of the perforated electrode plate (40a, b, c) opposing the tips of the corona discharge electrodes (31). A uniformly distributed corona discharge plasma (1000) is intermittently generated between the plurality of corona discharge electrode tips (31) and the catalyst member (60a, b, c, d) when a stream of flue gas is passed through the conduit. During those periods when corona discharge (1000) is not being generated, the catalyst molecules of the catalyst member (60a, b, c, d) adsorb mercury vapor contained in the passing flue gas. During those periods when corona discharge (1000) is being generated, ions and active radicals contained in the generated corona discharge plasma (1000) desorb the mercury from the catalyst molecules of the catalyst member (60a, b, c, d), oxidizing the mercury in virtually simultaneous manner. The desorption process regenerates and activates the catalyst member molecules.

Helfritch, Dennis J. (Baltimore, MD)

1998-07-28T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Laser techniques for studying chemical vapor deposition  

SciTech Connect

Chemical vapor deposition (CVD) is widely used to produce thin films for microelectronics, protective coatings and other materials processing applications. Despite the large number of applications, however, little is known about the fundamental chemistry and physics of most CVD processes. CVD recipes have generally been determined empirically, but as process requirements become more stringent, a more basic understanding will be needed to improve reactor design and speed process optimization. In situ measurements of the reacting gas are important steps toward gaining such an understanding, both from the standpoint of characterizing the reactor and testing models of a CVD process. Our work, a coordinated program of experimental and theoretical research in the fundamental mechanisms of CVD, illustrates the application of laser techniques to the understanding of a CVD system. We have used a number of laser-based techniques to probe CVD systems and have compared our measurements with predictions from computer models, primarily for the silane CVD system. The silane CVD model solves the two-dimensional, steady-state boundary layer equations of fluid flow coupled to 26 elementary chemical reactions describing the thermal decomposition of silane and the subsequent reactions of intermediate species that result in the deposition of a silicon film.

Ho, P.; Breiland, W.G.; Coltrin, M.E.

1990-01-01T23:59:59.000Z

362

ARM - Field Campaign - Arctic Winter Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsArctic Winter Water Vapor IOP govCampaignsArctic Winter Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Arctic Winter Water Vapor IOP 2004.03.09 - 2004.04.09 Lead Scientist : Ed Westwater Data Availability http://www.etl.noaa.gov/programs/2004/wviop/data will contain quicklooks of all of the data. For data sets, see below. Summary During the IOP, the Ground-based Scanning Radiometer of NOAA/ETL, and the ARM MicroWave Radiometer and Microwave Profiler, yielded excellent data over a range of conditions. In all, angular-scanned and calibrated radiometric data from 22.345 to 380 GHz were taken. The Precipitable Water Vapor varied about an order of magnitude from 1 to 10 mm, and surface temperatures varied from about -10 to -40 deg. Celcius. Vaisala RS90

363

Overview of the ARM/FIRE Water Vapor Experiment (AFWEX)  

NLE Websites -- All DOE Office Websites (Extended Search)

Overview of the ARM/FIRE Water Vapor Overview of the ARM/FIRE Water Vapor Experiment (AFWEX) D. C. Tobin, H. E. Revercomb, and D. D. Turner University of Wisconsin-Madison Madison, Wisconsin Introduction An overview of the ARM/FIRE Water Vapor Experiment (AFWEX) is given. This field experiment was conducted during November-December 2000 near the central ground-based Atmospheric Radiation Measurement (ARM) site in north central Oklahoma, and was sponsored jointly by the ARM, the National Aeronautics and Space Administration (NASA) First ISCCP Regional Experiment (FIRE), and the National Polar-orbiting Operational Environmental Satellite System (NPOESS) programs. Its primary goal was to collect accurate measurements of upper-level (~8 to 12 km) water vapor near the ground-based ARM site. These data are being used to determine the accuracy of measurements that are

364

Initiated chemical vapor deposition of functional polyacrylic thin films  

E-Print Network (OSTI)

Initiated chemical vapor deposition (iCVD) was explored as a novel method for synthesis of functional polyacrylic thin films. The process introduces a peroxide initiator, which can be decomposed at low temperatures (<200?C) ...

Mao, Yu, 1975-

2005-01-01T23:59:59.000Z

365

Low Level Heat Recovery Through Heat Pumps and Vapor Recompression  

E-Print Network (OSTI)

The intent of this paper is to examine the methods and economics of recovering low level heat through heat pumps and vapor recompression. Actual commercially available equipment is considered to determine the near-term and future economic viability...

Gilbert, J.

1980-01-01T23:59:59.000Z

366

Applications of Mechanical Vapor Recompression to Evaporation and Crystallization  

E-Print Network (OSTI)

there is no boiler plant available or when electrical power is priced competitively in comparison to steam. Vapor recompression is accomplished using centrifugal, axial-flow, or positive displacement compressors and these compressors can be powered by electricity...

Outland, J. S.

367

Enabling integration of vapor-deposited polymer thin films  

E-Print Network (OSTI)

Initiated Chemical Vapor Deposition (iCVD) is a versatile, one-step process for synthesizing conformal and functional polymer thin films on a variety of substrates. This thesis emphasizes the development of tools to further ...

Petruczok, Christy D. (Christy Danielle)

2014-01-01T23:59:59.000Z

368

Hyperfine Studies of Lithium Vapor using Saturated Absorption Spectroscopy  

E-Print Network (OSTI)

the frequency of a laser with respect to an atomic spectral feature.[20] As such, saturated absorptionHyperfine Studies of Lithium Vapor using Saturated Absorption Spectroscopy? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3.3 Broadening Mechanisms . . . . . . . . . . . . . . . . . . . . . 15 3.4 Saturated Absorption

Cronin, Alex D.

369

All graphene electromechanical switch fabricated by chemical vapor deposition  

E-Print Network (OSTI)

We demonstrate an electromechanical switch comprising two polycrystalline graphene films; each deposited using ambient pressure chemical vapor deposition. The top film is pulled into electrical contact with the bottom film ...

Milaninia, Kaveh M.

370

Systems and methods for generation of hydrogen peroxide vapor  

DOE Patents (OSTI)

A system according to one embodiment includes a moisture trap for drying air; at least one of a first container and a second container; and a mechanism for at least one of: bubbling dried air from the moisture trap through a hydrogen peroxide solution in the first container for producing a hydrogen peroxide vapor, and passing dried air from the moisture trap into a headspace above a hydrogen peroxide solution in the second container for producing a hydrogen peroxide vapor. A method according one embodiment includes at least one of bubbling dried air through a hydrogen peroxide solution in a container for producing a first hydrogen peroxide vapor, and passing dried air from the moisture trap into a headspace above the hydrogen peroxide solution in a container for producing a second hydrogen peroxide vapor. Additional systems and methods are also presented.

Love, Adam H; Eckels, Joel Del; Vu, Alexander K; Alcaraz, Armando; Reynolds, John G

2014-12-02T23:59:59.000Z

371

Optical Precursors in Rubidium Vapor and Their Relation to Superradiance  

E-Print Network (OSTI)

Optical precursor is the sharp optical pulse front that does not show delay in absorptive media. In this thesis, optical precursor behavior in rubidium (Rb) vapor was investigated in the picoseconds regime. An amplified femtosecond laser was shaped...

Yang, Wenlong

2012-10-19T23:59:59.000Z

372

Photocoupling of Methane in Water Vapor to Saturated Hydrocarbons  

Science Journals Connector (OSTI)

Methane can be converted into alkanes (from C2 to C6) continuously by ultraviolet (185nm) irradiation in the presence of water vapor. The products from this reaction are alkanes, which is different from the comp...

JunePyo Oh; Taketoshi Matsumoto; Junji Nakamura

2008-08-01T23:59:59.000Z

373

Mercury Vapor At Kawaihae Area (Thomas, 1986) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor At Kawaihae Area (Thomas, 1986) Mercury Vapor At Kawaihae Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Kawaihae Area (Thomas, 1986) Exploration Activity Details Location Kawaihae Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The soil geochemistry yielded quite complex patterns of mercury concentrations and radonemanation rates within the survey area (Cox and Cuff, 1981c). Mercury concentrations (Fig. 38) showed a general minimum along the Kawaihae-Waimea roads and a broad trend of increasing mercury concentrations toward both the north and south. There is no correlation apparent between the mercury patterns and either the resistivity sounding data or the surface geology in the area. The radon emanometry data (Fig.

374

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Exploration Activity Details Location Lualualei Valley Area Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Soil mercury and radon emanation surveys were performed over much of the accessible surface of Lualualei Valley (Cox and Thomas, 1979). The results of these surveys (Figs 7 and 8) delineated several areas in which soil mercury concentrations or radon emanation rates were substantially above normal background values. Some of these areas were apparently coincident with the mapped fracture systems associated with the caldera boundaries.

375

Function and Regulation of the Saccharomyces cerevisiae ENA Sodium ATPase System  

Science Journals Connector (OSTI)

...sodium when sodium is present in excess in the external medium relies...of sensitivity to sodium and lithium cations (31, 36, 70, 77...confer distinct sodium and lithium tolerances, with the former...The accumulation of sodium or lithium cations in calcineurin-deficient...

Amparo Ruiz; Joaqun Ario

2007-10-19T23:59:59.000Z

376

Advanced Chemical Heat Pumps Using Liquid-Vapor Reactions  

E-Print Network (OSTI)

ically feasible systems have significant potential advantage over conventional tech nology. An electric drive reactive heat pump can use smaller heat exchangers and compressor than a vapor-compression machine, and have more flexible operating... are discussed, and performance is bounded. A discussion on liquid-vapor equilibria is included as introduction to the systems I- considered. The electric drive heat pump and TA are promising systems; the TA has potential for higher COP than absorption...

Kirol, L.

377

D/sup -/ production by charge transfer in metal vapors  

SciTech Connect

Fast D/sup -/ ions can be produced from D/sup +/ by multiple charge-transfer collisions in a metal-vapor target. Experimental cross sections and thick-target D/sup -/ yields are presented and discussed. The high D/sup -/ yield experimentally observed from charge transfer in cesium vapor is consistent with recent low-energy cross-section calculations and measurements.

Schlachter, A.S.

1980-10-01T23:59:59.000Z

378

Injection locked oscillator system for pulsed metal vapor lasers  

DOE Patents (OSTI)

An injection locked oscillator system for pulsed metal vapor lasers is disclosed. The invention includes the combination of a seeding oscillator with an injection locked oscillator (ILO) for improving the quality, particularly the intensity, of an output laser beam pulse. The present invention includes means for matching the first seeder laser pulses from the seeding oscillator to second laser pulses of a metal vapor laser to improve the quality, and particularly the intensity, of the output laser beam pulse.

Warner, Bruce E. (Livermore, CA); Ault, Earl R. (Dublin, CA)

1988-01-01T23:59:59.000Z

379

Tank 241-S-102 headspace gas and vapor characterization results for samples collected in March 1995  

SciTech Connect

Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

Huckaby, J.L. [Pacific Northwest Lab., Richland, WA (United States); Bratzel, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

1995-09-26T23:59:59.000Z

380

investigating the source, transport, and isotope fractionation of water vapor in the atmospheric boundary layer  

E-Print Network (OSTI)

investigating the source, transport, and isotope fractionation of water vapor in the atmospheric cospectral similarity for temperature and water vapor isotope fluxes. mixing ratio generator Routine field use in water vapor isotope research. The unit generates a stable water vapor mixing ratio by measuring

Minnesota, University of

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Calculating the vapor pressure of water from the second law of thermodynamics  

Science Journals Connector (OSTI)

Calculating the vapor pressure of water from the second law of thermodynamics ... Thermodynamics ...

M. H. Everdell

1969-01-01T23:59:59.000Z

382

The growth of vapor bubble and relaxation between two-phase bubble flow  

Science Journals Connector (OSTI)

This paper presents the behavior of the bubble growth and relaxation between vapor and superheated...

S. Mohammadein; Rama Subba Reddy Gorla

2003-01-01T23:59:59.000Z

383

Tank Vapor Characterization Project: Annual status report for FY 1996  

SciTech Connect

In Fiscal Year 1996, staff at the Vapor Analytical Laboratory at Pacific Northwest National Laboratory performed work in support of characterizing the vapor composition of the headspaces of radioactive waste tanks at the Hanford Site. Work performed included support for technical issues and sampling methodologies, upgrades for analytical equipment, analytical method development, preparation of unexposed samples, analyses of tank headspaces samples, preparation of data reports, and operation of the tank vapor database. Progress made in FY 1996 included completion and issuance of 50 analytical data reports. A sampling system comparison study was initiated and completed during the fiscal year. The comparison study involved the vapor sampling system (VSS), a truck-based system, and the in situ vapor sampling system (ISVS), a cart-based system. Samples collected during the study were characterized for inorganic, permanent gases, total non-methane organic compounds and organic speciation by SUMMA{trademark} and TST methods. The study showed comparable sampling results between the systems resulting in the program switching from the VSS to the less expensive ISVS methodology in late May 1996. A temporal study was initiated in January 1996 in order to understand the influences seasonal temperatures changes have on the vapors in the headspace of Hanford waste tanks. A holding time study was initiated in the fourth quarter of FY 1996. Samples were collected from tank S-102 and rushed to the laboratory for time zero analysis. Additional samples will be analyzed at 1, 2, 4, 8, 16, and 32 weeks.

Silvers, K.L.; Fruchter, J.S.; Huckaby, J.L.; Almeida, T.L.; Evans, J.C. Jr.; Pool, K.H.; Simonen, C.A.; Thornton, B.M.

1997-01-01T23:59:59.000Z

384

It's Elemental - Isotopes of the Element Sodium  

NLE Websites -- All DOE Office Websites (Extended Search)

Neon Neon Previous Element (Neon) The Periodic Table of Elements Next Element (Magnesium) Magnesium Isotopes of the Element Sodium [Click for Main Data] Most of the isotope data on this site has been obtained from the National Nuclear Data Center. Please visit their site for more information. Naturally Occurring Isotopes Mass Number Natural Abundance Half-life 23 100% STABLE Known Isotopes Mass Number Half-life Decay Mode Branching Percentage 18 1.3×10-21 seconds Proton Emission 100.00% 19 < 40 nanoseconds Proton Emission No Data Available 20 447.9 milliseconds Electron Capture with delayed Alpha Decay 20.05% Electron Capture 100.00% 21 22.49 seconds Electron Capture 100.00% 22 2.6027 years Electron Capture 100.00% 23 STABLE - - 24 14.997 hours Beta-minus Decay 100.00%

385

Mercury exosphere I. Global circulation model of its sodium component  

E-Print Network (OSTI)

Mercury exosphere I. Global circulation model of its sodium component Francois Leblanc a,*, R 2010 Accepted 27 April 2010 Available online 5 May 2010 Keywords: Mercury, Atmosphere Aeronomy a b s t r a c t Our understanding of Mercury's sodium exosphere has improved considerably in the last 5

Johnson, Robert E.

386

RESEARCH Open Access Half-molar sodium lactate infusion improves  

E-Print Network (OSTI)

RESEARCH Open Access Half-molar sodium lactate infusion improves cardiac performance in acute heart for the myocardium at rest and during stress. We tested the effects of half-molar sodium lactate infusion on cardiac by 1 ml/kg/h continuous infusion for 24 hours. The control group received only a 3 ml/kg bolus

Paris-Sud XI, Université de

387

Solgel synthesis of sodium and lithium based materials  

Science Journals Connector (OSTI)

Sodium and lithium cobaltates are important materials for thermoelectric and ... the solgel synthesis of sodium- and lithium-based materials by using acetate precursors. The produced Na2/3CoO2, Li(Ni1/3Mn1/3Co1/...

Sandra Hildebrandt; Andreas Eva

2012-09-01T23:59:59.000Z

388

Alternatives for sodium-potassium alloy treatment  

SciTech Connect

Sodium-potassium alloy (NaK) is currently treated at the Y-12 Plant by open burning. Due to uncertainties with future permits for this process alternative treatment methods were investigated, revealing that two treatment processes are feasible. One process reacts the NaK with water in a highly concentrated molten caustic solution (sodium and potassium hydroxide). The final waste is a caustic that may be used elsewhere in the plant. This process has two safety concerns: Hot corrosive materials used throughout the process present handling difficulties and the process must be carefully controlled (temperature and water content) to avoid explosive NaK reactions. To avoid these problems a second process was developed that dissolves NaK in a mixture of propylene glycol and water at room temperature. While this process is safer, it generates more waste than the caustic process. The waste may possibly be used as a carbon food source in biological waste treatment operations at the Y-12 Plant. Experiments were conducted to demonstrate both processes, and they showed that both processes are feasible alternatives for NaK treatment. Process flow sheets with mass balances were generated for both processes and compared. While the caustic process generates less waste, the propylene glycol process is safer in several ways (temperature, material handling, and reaction control). The authors recommend that the propylene glycol alternative be pursued further as an alternative for NaK treatment. To optimize this process for a larger scale several experiments should be conducted. The amount of NaK dissolved in propylene glycol and subsequent waste generated should be optimized. The offgas processes should be optimized. The viability of using this waste as a carbon food source at one of the Y-12 Plant treatment facilities should be investigated. If the state accepts this process as an alternative, design and construction of a pilot-scale treatment system should begin.

Takacs, T.J.; Johnson, M.E.

1993-04-08T23:59:59.000Z

389

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sodium Bearing Waste Treatment Sodium Bearing Waste Treatment Project - Contractor - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Contractor - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Contractor Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) contractor Operational Readiness Review (C-ORR). The review was conducted at the Idaho Site from February 27 to March 6, 2012. This report discusses the background, scope, results, and conclusions of the review, as well as

390

Independent Oversight Assessment, Idaho Cleanup Project Sodium Bearing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Idaho Cleanup Project Sodium Idaho Cleanup Project Sodium Bearing Waste Treatment Project - November 2012 Independent Oversight Assessment, Idaho Cleanup Project Sodium Bearing Waste Treatment Project - November 2012 November 2012 Assessment of Nuclear Safety Culture at the Idaho Cleanup Project Sodium Bearing Waste Treatment Project The U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), conducted an independent assessment of nuclear safety culture at the DOE Sodium Bearing Waste Treatment Project (SBWTP). The primary objective of the evaluation was to provide information regarding the status of the safety culture at SBWTP. The data collection phase of the assessment occurred in April and May 2012. SBWTP is one of DOE's largest nuclear

391

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sodium Bearing Waste Treatment Sodium Bearing Waste Treatment Project - Federal - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Federal - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Federal Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) DOE (Federal) Operational Readiness Review (D-ORR). The review was performed by the HSS Office of Safety and Emergency Management Evaluations and was intended to assess the effectiveness of the CORR process as implemented for

392

EIS-0287: Notice of Preferred Sodium Bearing Waste Treatment Technology |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Preferred Sodium Bearing Waste Treatment Preferred Sodium Bearing Waste Treatment Technology EIS-0287: Notice of Preferred Sodium Bearing Waste Treatment Technology Idaho High-Level Waste (HLW) and Facilities Disposition In October 2002, the U.S. Department of Energy (DOE or the Department) issued the Final Idaho High-Level Waste (HLW) and Facilities Disposition Environmental Impact Statement (DOE/EIS-0287 (Final EIS)). The Final EIS contains an evaluation of reasonable alternatives for the management of mixed transuranic waste/sodium bearing waste (SBW),1 mixed HLW calcine, and associated low-level waste (LLW), as well as disposition alternatives for HLW facilities when their missions are completed. DOE/EIS-0287, Notice of Preferred Sodium Bearing Waste Treatment Technology, Office of Environmental Management, Idaho, 70 FR 44598 (August

393

Production of sodium-22 from proton irradiated aluminum  

DOE Patents (OSTI)

A process for selective separation of sodium-22 from a proton irradiated minum target including dissolving a proton irradiated aluminum target in hydrochloric acid to form a first solution including aluminum ions and sodium ions, separating a portion of the aluminum ions from the first solution by crystallization of an aluminum salt, contacting the remaining first solution with an anion exchange resin whereby ions selected from the group consisting of iron and copper are selectively absorbed by the anion exchange resin while aluminum ions and sodium ions remain in solution, contacting the solution with an cation exchange resin whereby aluminum ions and sodium ions are adsorbed by the cation exchange resin, and, contacting the cation exchange resin with an acid solution capable of selectively separating the adsorbed sodium ions from the cation exchange resin while aluminum ions remain adsorbed on the cation exchange resin is disclosed.

Taylor, Wayne A. (Los Alamos, NM); Heaton, Richard C. (Los Alamos, NM); Jamriska, David J. (Los Alamos, NM)

1996-01-01T23:59:59.000Z

394

Theoretical Adiabatic Temperature and Chemical Composition of Sodium Combustion Flame  

SciTech Connect

Sodium fire safety analysis requires fundamental combustion properties, e.g., heat of combustion, flame temperature, and composition. We developed the GENESYS code for a theoretical investigation of sodium combustion flame.Our principle conclusions on sodium combustion under atmospheric air conditions are (a) the maximum theoretical flame temperature is 1950 K, and it is not affected by the presence of moisture; the uppermost limiting factor is the chemical instability of the condensed sodium-oxide products under high temperature; (b) the main combustion product is liquid Na{sub 2}O in dry air condition and liquid Na{sub 2}O with gaseous NaOH in moist air; and (c) the chemical equilibrium prediction of the residual gaseous reactants in the flame is indispensable for sodium combustion modeling.

Okano, Yasushi; Yamaguchi, Akira [O-arai Engineering Center (Japan)

2003-12-15T23:59:59.000Z

395

Sodium reflux pool-boiler solar receiver on-sun test results  

SciTech Connect

The efficient operation of a Stirling engine requires the application of a high heat flux to the relatively small area occupied by the heater head tubes. Previous attempts to couple solar energy to Stirling engines generally involved directly illuminating the heater head tubes with concentrated sunlight. In this study, operation of a 75-kW{sub t} sodium reflux pool-boiler solar receiver has been demonstrated and its performance characterized on Sandia's nominal 75-kW{sub t} parabolic-dish concentrator, using a cold-water gas-gap calorimeter to simulate Stirling engine operation. The pool boiler (and more generally liquid-metal reflux receivers) supplies heat to the engine in the form of latent heat released from condensation of the metal vapor on the heater head tubes. The advantages of the pool boiler include uniform tube temperature, leading to longer life and higher temperature available to the engine, and decoupling of the design of the solar absorber from the engine heater head. The two-phase system allows high input thermal flux, reducing the receiver size and losses, therefore improving system efficiency. The receiver thermal efficiency was about 90% when operated at full power and 800{degree}C. Stable sodium boiling was promoted by the addition of 35 equally spaced artificial cavities in the wetted absorber surface. High incipient boiling superheats following cloud transients were suppressed passively by the addition of small amounts of xenon gas to the receiver volume. Stable boiling without excessive incipient boiling superheats was observed under all operating conditions. The receiver developed a leak during performance evaluation, terminating the testing after accumulating about 50 hours on sun. The receiver design is reported here along with test results including transient operations, steady-state performance evaluation, operation at various temperatures, infrared thermography, x-ray studies of the boiling behavior, and a postmortem analysis.

Andraka, C E; Moreno, J B; Diver, R B; Moss, T A [Oak Ridge National Lab., TN (United States)] [Oak Ridge National Lab., TN (United States)

1992-06-01T23:59:59.000Z

396

City of Mishawaka, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Indiana (Utility Company) Indiana (Utility Company) Jump to: navigation, search Name City of Mishawaka Place Indiana Utility Id 12674 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Power Service Commercial Commerical(10kW or more) Commercial Commerical(less than 10kW) Commercial Electric Heating Commercial Municipal Electric Service Commercial Outdoor lighting- 1,000 watt mercury vapor lamp Lighting Outdoor lighting- 100 watt sodium lamp Lighting Outdoor lighting- 175 watt mercury vapor lamp Lighting

397

E-Print Network 3.0 - acetate sodium lactate Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

sodium-high lactate infusion'. Of course, it is easy to demonstrate that high lactate infusion... . Also, sodium-lactate infusion in humans ... Source: Ecole Polytechnique, Centre...

398

High-resolution lidar observations of mesospheric sodium and implications for adaptive optics  

Science Journals Connector (OSTI)

Observations of sodium density variability in the upper mesosphere/lower thermosphere, obtained using a high-resolution lidar system, show rapid fluctuations in the sodium centroid...

Pfrommer, Thomas; Hickson, Paul

2010-01-01T23:59:59.000Z

399

City of Lincoln Center, Kansas (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Center, Kansas (Utility Company) Center, Kansas (Utility Company) Jump to: navigation, search Name City of Lincoln Center Place Kansas Utility Id 11017 Utility Location Yes Ownership M NERC Location SPP NERC SPP Yes RTO SPP Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png City Commercial Dusk to Dawn Yardlights- 100 Watt HP Sodium Lighting City Commercial Dusk to Dawn Yardlights- 175 Watt Merc. Vapor Lighting City Commercial Dusk to Dawn Yardlights- 250 Watt HP Sodium Lighting

400

Monroe County Elec Power Assn | Open Energy Information  

Open Energy Info (EERE)

Power Assn Power Assn Place Mississippi Utility Id 40303 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rate Over 50 KW Commercial Commercial Rate Under 50 KW Commercial Demand Rate Outdoor Lights -100 watt Sodium Lighting Outdoor Lights 175 watt Mercury Vapor Lighting Outdoor Lights 400 watt Sodium Lighting Residential Rate Residential Average Rates Residential: $0.0916/kWh Commercial: $0.1110/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Greenwood Commissioners-Pub Wk | Open Energy Information  

Open Energy Info (EERE)

Commissioners-Pub Wk Commissioners-Pub Wk Jump to: navigation, search Name Greenwood Commissioners-Pub Wk Place South Carolina Utility Id 7646 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large Commercial Service rate V2 Commercial Large Commercial service rate Commercial Large Power service rate Industrial Large Power service rate V2 Industrial Lighting Service - 175 Watt Mercury Vapor Lighting Lighting service - 100 Watt High Pressure Sodium Lighting Lighting service - 1000 Watt High Pressure Sodium Lighting

402

Comanche County Elec Coop Assn | Open Energy Information  

Open Energy Info (EERE)

Comanche County Elec Coop Assn Comanche County Elec Coop Assn Jump to: navigation, search Name Comanche County Elec Coop Assn Place Texas Utility Id 4295 Utility Location Yes Ownership C NERC Location TRE NERC ERCOT Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service - Three Phase Service Commercial General Service-Single Phase Commercial Large Power Rate Industrial Large Power Rate Primary Metering Industrial Residential Residential SECURITY LIGHTS:100 watt HP Sodium Lighting SECURITY LIGHTS:175 watt Mercury Vapor Lighting SECURITY LIGHTS:250 watt HP Sodium Lighting

403

Delta Electric Power Assn | Open Energy Information  

Open Energy Info (EERE)

Delta Electric Power Assn Delta Electric Power Assn Place Mississippi Utility Id 22815 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 01 Farm and Residential Electric Service Residential 09 Residential Electric Service Water Heater Residential 10 All Electric Residential Service Residential 12 Small Commercial Service Commercial 13 Street Lighting High Pressure Sodium 100 Watt Lighting 13 Street Lighting High Pressure Sodium 400 Watt Lighting 13 Street Lighting Mercury Vapor 175 Watt enclosed Lighting

404

Chapter 13. No Watt Left Behind No Watt Left Behind  

E-Print Network (OSTI)

­ from the smallest refrigerator to the largest building air-conditioning system ­ become fouled of previous forays. Much of the current thinking for making buildings "smart" about their energy consumption. This information is essential in order to understand and optimize energy consumption, to detect and #12;Chapter 13

405

Mercury Source Zone Identification using Soil Vapor Sampling and Analysis  

SciTech Connect

Development and demonstration of reliable measurement techniqes that can detect and help quantify the nature and extent of elemental mercury (Hg(0)) in the subsurface are needed to reduce certainties in the decision making process and increase the effectiveness of remedial actions. We conducted field tests at the Y-12 National Security Complex (NSC) in Oak Ridge, TN, to determine if sampling and analysis of Hg(0) vapors in the shallow subsurface (<0.3 m depth) can be used to as an indicator of the location and extent of Hg(0) releases in the subsurface. We constructed a rigid PVC pushprobe assembly, which was driven into the ground. Soil gas samples were collected through a sealed inner tube of the assembly and analyzed immediately in the field with a Lumex and/or Jerome Hg(0) analyzer. Time-series sampling showed that Hg vapor concentrations were fairly stable over time suggesting that the vapor phase Hg(0) was not being depleted and that sampling results were not dependent on the soil gas purge volume. Hg(0) vapor data collected at over 200 pushprobe locations at 3 different release sites correlated well to areas of known Hg(0) contamination. Vertical profiling of Hg(0) vapor concentrations conducted at 2 locations provided information on the vertical distribution of Hg(0) contamination in the subsurface. We concluded from our studies that soil gas sampling and analysis can be conducted rapidly and inexpensively at a large scale to help identify areas contaminated with Hg(0).

Watson, David B [ORNL] [ORNL; Miller, Carrie L [ORNL] [ORNL; Lester, Brian P [ORNL] [ORNL; Lowe, Kenneth Alan [ORNL] [ORNL; Southworth, George R [ORNL] [ORNL; Bogle, Mary Anna [ORNL] [ORNL; Liang, Liyuan [ORNL] [ORNL; Pierce, Eric M [ORNL] [ORNL

2014-01-01T23:59:59.000Z

406

Vapor etching of nuclear tracks in dielectric materials  

DOE Patents (OSTI)

A process involving vapor etching of nuclear tracks in dielectric materials for creating high aspect ratio (i.e., length much greater than diameter), isolated cylindrical holes in dielectric materials that have been exposed to high-energy atomic particles. The process includes cleaning the surface of the tracked material and exposing the cleaned surface to a vapor of a suitable etchant. Independent control of the temperatures of the vapor and the tracked materials provide the means to vary separately the etch rates for the latent track region and the non-tracked material. As a rule, the tracked regions etch at a greater rate than the non-tracked regions. In addition, the vapor-etched holes can be enlarged and smoothed by subsequent dipping in a liquid etchant. The 20-1000 nm diameter holes resulting from the vapor etching process can be useful as molds for electroplating nanometer-sized filaments, etching gate cavities for deposition of nano-cones, developing high-aspect ratio holes in trackable resists, and as filters for a variety of molecular-sized particles in virtually any liquid or gas by selecting the dielectric material that is compatible with the liquid or gas of interest.

Musket, Ronald G. (Danville, CA); Porter, John D. (Berkeley, CA); Yoshiyama, James M. (Fremont, CA); Contolini, Robert J. (Lake Oswego, OR)

2000-01-01T23:59:59.000Z

407

Risk Management for Sodium Fast Reactors.  

SciTech Connect

Accident management is an important component to maintaining risk at acceptable levels for all complex systems, such as nuclear power plants. With the introduction of self - correcting, or inherently safe, reactor designs the focus has shifted from management by operators to allowing the syste m's design to manage the accident. While inherently and passively safe designs are laudable, extreme boundary conditions can interfere with the design attributes which facilitate inherent safety , thus resulting in unanticipated and undesirable end states. This report examines an inherently safe and small sodium fast reactor experiencing a beyond design basis seismic event with the intend of exploring two issues : (1) can human intervention either improve or worsen the potential end states and (2) can a Bayes ian Network be constructed to infer the state of the reactor to inform (1). ACKNOWLEDGEMENTS The author s would like to acknowledge the U.S. Department of E nergy's Office of Nuclear Energy for funding this research through Work Package SR - 14SN100303 under the Advanced Reactor Concepts program. The authors also acknowledge the PRA teams at A rgonne N ational L aborator y , O ak R idge N ational L aborator y , and I daho N ational L aborator y for their continue d contributions to the advanced reactor PRA mission area.

Denman, Matthew R; Groth, Katrina; Cardoni, Jeffrey N; Wheeler, Timothy A.

2015-01-01T23:59:59.000Z

408

Pulse radiolysis of solutions of sodium tetraphenylborate  

SciTech Connect

Pulse radiolysis of solutions of sodium tetraphenylborate (NaBPh/sub 4/) indicates that the absorption observed in organic amides with lambda/sub max/ in the range 650-724 nm is not due to Na/sup -/, an electron adduct to BPh/sub 4//sup -/, a triplet excited state, or a proton-donating solvent cation. Experiments in aqueous solution are described in which the reactions of selected radicals with NaBPh/sub 4/ are studied. One-electron oxidation of NaBPh/sub 4/ by N/sub 3//sup .-/ radicals yields a species, assumed to be NaBPh/sub 4//sup ./, with absorption maxima at 335 and 800 nm. A similar spectrum is observed on pulse radiolysis of solutions of NaBPh/sub 4/ in tetramethylurea (TMU), but the long-wavelength absorption is shifted to 725 nm. The formation of an oxidizing radical in irradiated TMU was confirmed by the observation of I/sub 2//sup .-/ on pulse radiolysis of solutions of KI in this solvent. Pulse radiolysis of solution of NaBPh/sub 4/ and KI in TMU demonstrated that these solutes compete for the oxidizing intermediate.

Liu, K.J.; Langan, J.R.; Salmon, G.A.; Holton, D.M.; Edwards, P.P.

1988-05-05T23:59:59.000Z

409

Validation of TES Temperature and Water Vapor Retrievals with ARM  

NLE Websites -- All DOE Office Websites (Extended Search)

Validation of TES Temperature and Water Vapor Retrievals with ARM Validation of TES Temperature and Water Vapor Retrievals with ARM Observations Cady-Pereira, Karen Atmospheric and Environmental Research, Inc. Shephard, Mark Atmospheric and Environmental Research, Inc. Clough, Shepard Atmospheric and Environmental Research Mlawer, Eli Atmospheric & Environmental Research, Inc. Turner, David University of Wisconsin-Madison Category: Atmospheric State and Surface The primary objective of the TES (Tropospheric Emission Spectrometer) instrument on the Aura spacecraft is the retrieval of trace gases, especially water vapor and ozone. The TES retrievals extremely useful for global monitoring of the atmospheric state, but they must be validated. The ARM sites are well instrumented and provide continuous measurements, which

410

VAPORIZATION OF TUNGSTEN-METAL IN STEAM AT HIGH TEMPERATURES.  

SciTech Connect

The vaporization of tungsten from the APT spallation target dominates the radiological source term for unmitigated target overheating accidents. Chemical reactions of tungsten with steam which persist to tungsten temperatures as low as 800 C result in the formation of a hydrated tungsten-oxide which has a high vapor pressure and is readily convected in a flowing atmosphere. This low-temperature vaporization reaction essentially removes the oxide film that forms on the tungsten-metal surface as soon as it forms, leaving behind a fresh metallic surface for continued oxidation and vaporization. Experiments were conducted to measure the oxidative vaporization rates of tungsten in steam as part of the effort to quantify the MT radiological source term for severe target accidents. Tests were conducted with tungsten rods (1/8 inch diameter, six inches long) heated to temperatures from approximately 700 C to 1350 C in flowing steam which was superheated to 140 C. A total of 19 experiments was conducted. Fifteen tests were conducted by RF induction heating of single tungsten rods held vertical in a quartz glass retort. Four tests were conducted in a vertically-mounted tube furnace for the low temperature range of the test series. The aerosol which was generated and transported downstream from the tungsten rods was collected by passing the discharged steam through a condenser. This procedure insured total collection of the steam along with the aerosol from the vaporization of the rods. The results of these experiments revealed a threshold temperature for tungsten vaporization in steam. For the two tests at the lowest temperatures which were tested, approximately 700 C, the tungsten rods were observed to oxidize without vaporization. The remainder of the tests was conducted over the temperature range of 800 C to 1350 C. In these tests, the rods were found to have lost weight due to vaporization of the tungsten and the missing weight was collected in the downstream condensate system. The aerosol formed a fine white smoke of tungsten-oxide which was visible to the eye as it condensed in the laminar boundary layer of steam which flowed along the surface of the rod. The aerosol continued to flow as a smoke tube downstream of the rod, flowing coaxially along the centerline axis of the quartz glass tube and depositing by impaction along the outside of a bend and at sudden area contractions in the piping. The vaporization rate data from the 17 experiments which exceeded the vaporization threshold temperature are shown in Figure 5 in the form of vaporization rates (g/cm{sup 2} s) vs. inverse temperature (K{sup {minus}1}). Two correlations to the present data are presented and compared to a published correlation by Kilpatrick and Lott. The differences are discussed.

GREENE,G.A.; FINFROCK,C.C.

2000-10-01T23:59:59.000Z

411

Sodium bromide electron-extraction layers for polymer bulk-heterojunction solar cells  

SciTech Connect

Inexpensive and non-toxic sodium bromide (NaBr) was introduced into polymer solar cells (PSCs) as the cathode buffer layer (CBL) and the electron extraction characteristics of the NaBr CBL were investigated in detail. The PSCs based on NaBr CBL with different thicknesses (i.e., 0?nm, 0.5?nm, 1?nm, and 1.5?nm) were prepared and studied. The optimal thickness of NaBr was 1?nm according to the photovoltaic data of PSCs. The open-circuit voltage (V{sub oc}), short-circuit current density (J{sub sc}), fill factor (FF), and power conversion efficiency (PCE) of the PSC with 1?nm NaBr were evaluated to be 0.58?V, 7.36?mA/cm{sup 2}, 0.63, and 2.70%, respectively, which were comparable to those of the reference device with the commonly used LiF. The optimized photovoltaic performance of PSC with 1?nm NaBr was ascribed to the improved electron transport and extraction capability of 1?nm NaBr in PSCs. In addition, the NaBr CBL could prevent the diffusion of oxygen and water vapor into the active layer and prolong the lifetime of the devices to some extent. Therefore, NaBr layer could be considered as a promising non-toxic CBL for PSCs in future.

Gao, Zhi; Qu, Bo, E-mail: bqu@pku.edu.cn; Xiao, Lixin; Chen, Zhijian [State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China) [State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China); New Display Device and System Integration Collaborative Innovation Center of the West Coast of the Taiwan Strait, Fuzhou 350002 (China); Zhang, Lipei [State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China)] [State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China); Gong, Qihuang [State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China) [State Key Laboratory for Artificial Microstructures and Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter, Beijing 100871 (China)

2014-03-10T23:59:59.000Z

412

Internal structure, hygroscopic and reactive properties of mixed sodium  

NLE Websites -- All DOE Office Websites (Extended Search)

Internal structure, hygroscopic and Internal structure, hygroscopic and reactive properties of mixed sodium methanesulfonate-sodium chloride particles Internal structure, hygroscopic and reactive properties of mixed sodium methanesulfonate-sodium chloride particles Print Friday, 13 May 2011 00:00 Scientists recently combined experimental approaches and molecular dynamics modeling to gain new insights into the internal structure of sea salt particles and relate it to their fundamental chemical reactivity in the atmosphere. This research shows that surface enhancement or depletion of chemical components in marine particles can occur because of the difference in the chemical nature of the species. Because the atmospheric chemistry of the salt particles takes place at the gas-particle interface, understanding their complex surfaces provides new insights about their effect on the environment and climate change. Article Link.

413

Loop simulation capability for sodium-cooled systems  

E-Print Network (OSTI)

A one-dimensional loop simulation capability has been implemented in the thermal-hydraulic analysis code, THERMIT-4E. This code had been used to simulate and investigate flow in test sections of experimental sodium loops ...

Adekugbe, Oluwole A.

1984-01-01T23:59:59.000Z

414

Neutron Activation Analysis of Manganese and Sodium in Bacterial Cells  

Science Journals Connector (OSTI)

...research-article Metabolism and Products Neutron Activation Analysis of Manganese and Sodium...Columbus, Ohio 43210. The application of neutron activation analysis for mineral determinations...two elements. The results indicate that neutron activation analysis is readily applicable...

Woodrow B. Krueger; Walter E. Carey; Bruno J. Kolodzeij

1970-12-01T23:59:59.000Z

415

Phase effects for electrons in liquid water and water vapor  

SciTech Connect

The objective of these studies is to compare transport, energy loss, and other phenomena for electrons in water in the liquid and vapor phases. Understanding the differences and similarities is an interesting physics problem in its own right. It is also important for applying the relatively large body of experimental data available for the vapor to the liquid, which is of greater relevance in radiobiology. This paper presents a summary of results from a series of collaborative studies carried out by the authors at Oak Ridge National Laboratory (ORNL) and the Gesellschaft fuer Strahlen- und Umweltforschung (GSF). 14 figs.

Turner, J.E.; Paretzke, H.G.; Wright, H.A.; Hamm, R.N.; Ritchie, R.H.

1988-01-01T23:59:59.000Z

416

Growth of manganese filled carbon nanofibers in the vapor phase  

Science Journals Connector (OSTI)

We report the vapor phase growth of partially filled graphitic fibers, 20-30 nm in diameter and up to a micron in length, during a manganese catalyzed carbon electric arc discharge. The fiber morphology resembles that of catalytic chemical vapor deposited carbon filaments but the inside hollow contains intermittent precipitates and continuous filling of Mn that at times occupy >50% of fiber lengths. Transmission electron microscopy and electron energy loss line spectra show that the fillings form as solid cores and may correspond to pure metal.

P. M. Ajayan; C. Colliex; J. M. Lambert; P. Bernier; L. Barbedette; M. Tence; O. Stephan

1994-03-14T23:59:59.000Z

417

The development of a passive dosimeter for airborne aniline vapors  

E-Print Network (OSTI)

passive sampl1ng dosimeter was designed to measure concen- trat1ons of aniline vapor in air. Diffus1on tubes of 1. 5, 3. 0 and 4. 5 cm lengths were tested under controlled conditions of relative humid1ty, air temperature and vapor concentrations. A... of Measured vs Calculated Concentrations APPENDIX D-Student-t Test on Slopes of Measured vs Calculated Data . APPENDIX E-Statistical Analysis of Four Hour Time- Weighted Average Study on 3. 0 cm Dosimeter VITA ~pa e 42 45 48 59 62 63 65 70 73...

Campbell, James Evan

1977-01-01T23:59:59.000Z

418

SolidLiquidVapor Equilibrium Models for Cryogenic Biogas Upgrading  

Science Journals Connector (OSTI)

In cryogenic upgrading processes involving dry ice formation, accurate predictions of solidliquid, solidvapor, and solidliquidvapor equilibria are fundamental for a correct design of the heat exchanger surface in order to achieve the desired biomethane purity. ... Moreover, the liquefied biogas production process, particularly interesting for cryogenic upgrading processes due to the low temperature of the obtained biomethane, requires an accurate knowledge of carbon dioxide solubility in liquid methane to avoid solid deposition. ... For some applications demanding a high energy content gas, namely vehicle fuels and injection in the natural gas grid, the biogas has to be upgraded into biomethane. ...

Mauro Riva; Marco Campestrini; Joseph Toubassy; Denis Clodic; Paolo Stringari

2014-10-13T23:59:59.000Z

419

The Salt or Sodium Chloride Content of Feeds  

E-Print Network (OSTI)

1 EXAS AGRICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, Preeident BULLETIN NO. 271 OCTOBER, 1920 DIVISION OF CHEMISTRY THE SALT OR SODIUM CHLORIDE CONTENT OF FEEDS B. YOUNGBLOOD, DIRECTOK COLLEGE.... ............... Salt content of feecls.. ......... Salt content of mixed feeds.. ................... Summary ancl conclusions. Page. l1 [Blank Page in Original Bulletin] BULLETIN XO. 271. OCTOBE- '"On THE SALT OR SODIUM CHLORIDE CONTENT OF FEI The Texas feed...

Fraps, G. S. (George Stronach); Lomanitz, S. (Sebastian)

1920-01-01T23:59:59.000Z

420

Data:9ed8f281-7c9a-4f4f-a8f0-1fabf477296b | Open Energy Information  

Open Energy Info (EERE)

-7c9a-4f4f-a8f0-1fabf477296b -7c9a-4f4f-a8f0-1fabf477296b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-250 W SV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Data:506e7491-7a10-4e8b-bf1b-8e28fdee71d1 | Open Energy Information  

Open Energy Info (EERE)

91-7a10-4e8b-bf1b-8e28fdee71d1 91-7a10-4e8b-bf1b-8e28fdee71d1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-175 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

422

Method of and apparatus for removing silicon from a high temperature sodium coolant  

DOE Patents (OSTI)

A method of and system for removing silicon from a high temperature liquid sodium coolant system for a nuclear reactor. The sodium is cooled to a temperature below the silicon saturation temperature and retained at such reduced temperature while inducing high turbulence into the sodium flow for promoting precipitation of silicon compounds and ultimate separation of silicon compound particles from the liquid sodium.

Yunker, Wayne H. (Richland, WA); Christiansen, David W. (Kennewick, WA)

1987-01-01T23:59:59.000Z

423

City of Johnson City, Tennessee (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Johnson City City of Johnson City City of Place Tennessee Utility Id 9777 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GENERAL POWER RATE - GSA 1 - 1PH (Rate 440) Commercial GENERAL POWER RATE - GSA 1 - 3PH (Rate 440) Commercial GENERAL POWER RATE - GSA 2 (Rate 550) Commercial GENERAL POWER RATE - GSA 3 (Rate 554) Commercial RS Residential Rate 556 Seasonal - Over 5,000 KW Commercial SECURITY LIGHTS 100 WATT SODIUM VAPOR Lighting SECURITY LIGHTS 250 WATT SODIUM VAPOR Lighting

424

Duncan Valley Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name Duncan Valley Elec Coop, Inc Place Arizona Utility Id 5438 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes ISO Other Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Schedule LS - Private Area Lighting Service(100 and 175 watt mercury and sodium vapor) Lighting Schedule LS - Private Area Lighting Service with pole(100 and 175 watt mercury and sodium vapor) Lighting Schedule PSHL - Public Street & Highway Lighting - 100W Lamp Lighting Schedule PSHL - Public Street & Highway Lighting - 175W Lamp Lighting

425

UNCORRECTEDPROOF 2 Vaporization, fusion and sublimation enthalpies of the  

E-Print Network (OSTI)

UNCORRECTEDPROOF 2 Vaporization, fusion and sublimation enthalpies of the 3 dicarboxylic acids from of Chemistry and Biochemistry, University of Missouri-St. Louis, 8001 Natural Bridge, St. Louis, MO 63121, USA observed previously in the sublimation enthalpies of these compounds. The results are dis- 16 cussed

Chickos, James S.

426

Vapor-side corrosion in thermal desalination plants  

SciTech Connect

This article reports the results of vapor-size corrosion monitoring studies carried out in multistage flash (MSF) desal unit No. 100 of Al-Khafji power and Desalination Plant in Saudi Arabia. Corrosion behavior of 70/30 Cu-Ni alloy, carbon steel (CS), and type 316L stainless steel (SS) was studied in vents and in the vapor size of distillers for 2,000, 4,000, and 9,000 h. Analyses of the experimental data indicated that in addition to O{sub 2}, S-containing compounds evolved during flashing of seawater reacted more with Cu-Ni alloy than with CS and type 316L SS. Explanations for comparatively higher corrosion of alloys exposed to the vapors of the first three (1 to 3) and middle (11 to 13) stages of the MSF plant are given with experimental results. Type 316L SS was found to be the alloy most resistant to vapor-side corrosion in all stages of distillers.

Asrar, N.; Malik, A.U.; Ahmed, S. [Saline Water Conversion Corp. (Saudi Arabia); Al-Khalidi, M.; Al-Moaili, K. [Al-Khafji Desalination Plant (Saudi Arabia)

1999-04-01T23:59:59.000Z

427

Fatigue Resistance of Asphalt Mixtures Affected by Water Vapor Movement  

E-Print Network (OSTI)

This dissertation has two key objectives: the first objective is to develop a method of predicting and quantifying the amount of water that can enter into a pavement system by vapor transport; the second objective is to identify to which extent...

Tong, Yunwei

2013-11-08T23:59:59.000Z

428

The chemical vapor deposition of zirconium carbide onto ceramic substrates  

SciTech Connect

Zirconium carbide is an attractive ceramic material due to its unique properties such as high melting point, good thermal conductivity, and chemical resistance. The controlled preparation of zirconium carbide films of superstoichiometric, stoichiometric, and substoichiometric compositions has been achieved utilizing zirconium tetrachloride and methane precursor gases in an atmospheric pressure high temperature chemical vapor deposition system.

Glass, John A, Jr.; Palmisiano, Nick, Jr.; Welsh, R. Edward

1999-07-01T23:59:59.000Z

429

A transient model for a cesium vapor thermionic converter. [Cs  

SciTech Connect

This paper presents an analytical model for simulating the transient and steady-state operation of cesium vapor thermionic converters. A parametric analysis is performed to assess the transient response of the converter to changes in fission power and width of interelectrode gap. The model optimizes the converter performance for maximum electric power to the load.(AIP)

El-Genk, M.S.; Murray, C.S.; Chaudhuri, S. (Institute for Space Nuclear Power Studies, Department of Chemical and Nuclear Engineering, The University of New Mexico, Albuquerque, New Mexico (USA))

1991-01-10T23:59:59.000Z

430

Experimental Study of Water Vapor Adsorption on Geothermal  

E-Print Network (OSTI)

Geothermal Program under Department of Energy Grant No. DE-FG07-90IDI2934,and by the Department of PetroleumSGP-TR-148 Experimental Study of Water Vapor Adsorption on Geothermal Reservoir Rocks Shubo Shang Engineering, Stanford University Stanford Geothermal Program Interdisciplinary Research in Engineering

Stanford University

431

CVD CNT CNT (Vapor-grown carbon fiber, VGCF)  

E-Print Network (OSTI)

CNT CNT CVD CNT CNT (Vapor-grown carbon fiber, VGCF) 10001300 CNT CVD Smalley CO 24 CCVD 1 #12; 27 mm 3% 200 sccm 800 10 10 Torr 300 sccm Ethanol tank Hot bath boat Ar/H2 Ar or Ethanol tank Hot bath Ethanol tank Hot bath Pressure gauge Maindraintube Subdraintube

Maruyama, Shigeo

432

Method for removing metal vapor from gas streams  

DOE Patents (OSTI)

A process for cleaning an inert gas contaminated with a metallic vapor, such as cadmium, involves withdrawing gas containing the metallic contaminant from a gas atmosphere of high purity argon; passing the gas containing the metallic contaminant to a mass transfer unit having a plurality of hot gas channels separated by a plurality of coolant gas channels; cooling the contaminated gas as it flows upward through the mass transfer unit to cause contaminated gas vapor to condense on the gas channel walls; regenerating the gas channels of the mass transfer unit; and, returning the cleaned gas to the gas atmosphere of high purity argon. The condensing of the contaminant-containing vapor occurs while suppressing contaminant particulate formation, and is promoted by providing a sufficient amount of surface area in the mass transfer unit to cause the vapor to condense and relieve supersaturation buildup such that contaminant particulates are not formed. Condensation of the contaminant is prevented on supply and return lines in which the contaminant containing gas is withdrawn and returned from and to the electrorefiner and mass transfer unit by heating and insulating the supply and return lines.

Ahluwalia, R. K. (6440 Hillcrest Dr., Burr Ridge, IL 60521); Im, K. H. (925 Lehigh Cir., Naperville, IL 60565)

1996-01-01T23:59:59.000Z

433

Sorption and Diffusion of Organic Vapors in Two Fluoroelastomers  

E-Print Network (OSTI)

Sorption and Diffusion of Organic Vapors in Two Fluoroelastomers PING WANG,* NATHANIEL S. SCHNEIDER of II in polar liquids: over 100% (wt/wt) in two ketones and a phosphate ester. Sorption isotherms deter determined from sorption kinetics, corrected for nonisothermal effects, and converted to solvent self

Wang, Ping

434

High-resolution terahertz atmospheric water vapor continuum measurements  

E-Print Network (OSTI)

High-resolution terahertz atmospheric water vapor continuum measurements David M. Slocum,* Thomas M such as pollution monitoring and the detection of energetic chemicals using remote sensing over long path lengths through the atmosphere. Although there has been much attention to atmospheric effects over narrow

Massachusetts at Lowell, University of

435

Method and apparatus to measure vapor pressure in a flow system  

DOE Patents (OSTI)

The present invention is directed to a method for determining, by a condensation method, the vapor pressure of a material with a known vapor pressure versus temperature characteristic, in a flow system particularly in a mercury isotope enrichment process.

Grossman, Mark W. (Belmont, MA); Biblarz, Oscar (Swampscott, MA)

1991-01-01T23:59:59.000Z

436

Tropical Water Vapor and Cloud Feedbacks in Climate Models: A Further Assessment Using Coupled Simulations  

Science Journals Connector (OSTI)

By comparing the response of clouds and water vapor to ENSO forcing in nature with that in Atmospheric Model Intercomparison Project (AMIP) simulations by some leading climate models, an earlier evaluation of tropical cloud and water vapor ...

De-Zheng Sun; Yongqiang Yu; Tao Zhang

2009-03-01T23:59:59.000Z

437

Metalorganic chemical vapor deposition of carbon-free ZnO using...  

NLE Websites -- All DOE Office Websites (Extended Search)

Metalorganic chemical vapor deposition of carbon-free ZnO using the bis(2,2,6,6-tetramethyl-3,5-heptanedionato)zinc precursor. Metalorganic chemical vapor deposition of carbon-free...

438

Economic and Technical Tradeoffs Between Open and Closed Cycle Vapor Compression Evaporators  

E-Print Network (OSTI)

and solute. Evaporation tends to be a very energy intensive process. Approximately 1000 BTUs of energy are required to vaporize one pound of water. Many techniques have been developed to reuse energy Within an evaporation system so as to vaporize... Recompression A schematic of an open cycle vapor recompression evaporator is shown in Figure 2. This method uses the vapor in an open cycle for both heating and cooling. Rather than being condensed after the last effect, steam is compressed to a slightly...

Timm, M. L.

439

Quantitative Analysis of Ternary Vapor Mixtures Using a Microcantilever-Based Electronic Nose  

SciTech Connect

The authors report the identification and quantification of the components of a ternary vapor mixture using a microcantilever-based electronic nose. An artificial neural network was used for pattern recognition. Dimethyl methyl phosphonate vapor in ppb concentrations and water and ethanol vapors in ppm concentrations were quantitatively identified either individually or in binary and ternary mixtures at varying concentrations.

Pinnaduwage, Lal A [ORNL; Zhao, Weichang [ORNL; Gehl, Anthony C [ORNL; Allman, Steve L [ORNL

2007-01-01T23:59:59.000Z

440

Sample Vapor Introduction Techniques for Use with Cryofocusing GC Inlet Systems  

Science Journals Connector (OSTI)

......the vapor generator was operated at atmospheric pressure for...condensed water. Other studies...Because the water vapor was...tail of the water peak. Thus...obtained from an atmospheric pressure source...the vapor generator over a 1......

Christine L. Rankin; Richard D. Sacks

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Measurements of atmospheric water vapor above Mauna Kea using an infrared radiometer  

E-Print Network (OSTI)

Measurements of atmospheric water vapor above Mauna Kea using an infrared radiometer David A in atmospheric water vapor that distort the phase coherence of incoming celestial signals. The signal received water vapor, this paper presents results obtained with a second generation IRMA operating at the James

Naylor, David A.

442

Development of under sodium inspection techniques for FBR  

SciTech Connect

The reactor vessel of a fast breeder reactor (FBR) is filled with opaque liquid sodium and ultrasonic inspection techniques are effective and useful for observing the in-vessel structures under sodium. Firstly, in the development of the under sodium visual inspection technique, the synthetic aperture focusing technique (SAFT) and cross-correlation processing have been applied to realize ultrasonic 3-dimensional cross-correlation image processing with high resolution. Cross-correlation processing improves the S/N ratio of the ultrasonic echoes which are deteriorated by sodium wetting, and realizes high-density integration of the matrix arrayed transducer. Matrix arrayed transducer, in which 100 piezoelectric elements are arranged as a 10 x 10 matrix array, has been manufactured for the in-water visualizing test. Secondly, in the development of the under sodium volumetric inspection technique, a prototype electric scanning UT sensor has been developed for the volumetric test of the core support structures in the reactor vessel. The UT sensor consists of 60 arrayed piezoelectric elements, non-organic materials such as ceramic backing. Ultrasonic echoes transmitted from the elements is scanned electronically and real-time B-scope images of the structures can be realized. A prototype UT sensor has been tested to evaluate the acoustic characteristics in water and confirm the heat-proof performance under high temperature silicon oil. The performance of the UT sensor satisfied the requirements.

Karasawa, H.; Suzuki, T.; Nagai, S.; Izumi, M.; Kobayashi, T. [Toshiba Corp., Yokohama (Japan); Sasaki, S.; Ota, S.; Kai, M. [Japan Atomic Power Co., Tokyo (Japan)

1996-08-01T23:59:59.000Z

443

ESS 2012 Peer Review - Sodium-based Battery Development - Dave Ingersoll, SNL  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sodium-based Battery Development Sodium-based Battery Development A Family of Batteries for Large Scale Energy Storage D. Ingersoll, C. Apblett, E. Spoerke, K. Zavadil, R. Cygan, J. Ihlefeld, F. Delnick, & T. Anderson Sandia National Laboratories, Albuquerque, NM Prof. E. Wachsman University of Maryland, College Park, MD Profs. R. Kee & J. Porter, Dr. H. Zhu Colorado School of Mines, Golden, CO S. Bhavaraju & M. Robins Ceramatec, Inc, Salt Lake City, UT D. Beeaff CoorsTek, Inc, Golden, CO J. Martin Boulder Ionics, Golden CO US DOE Energy Storage Systems Research Program Peer Review, Washington, DC, Sept. 26-28, 2012 Sodium-based batteries  Purpose  Demonstrate a family of sodium-based battery chemistries  sodium-iodine, sodium-bromine, sodium-air, sodium insertion, sodium-metal, etc

444

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Contractor - June 2012 Contractor - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Contractor - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Contractor Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) contractor Operational Readiness Review (C-ORR). The review was conducted at the Idaho Site from February 27 to March 6, 2012. This report discusses the background, scope, results, and conclusions of the review, as well as opportunities for improvement (OFIs) and items identified for further

445

Generation IV International Forum Signs Agreement to Collaborate on Sodium  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Forum Signs Agreement to Collaborate on Forum Signs Agreement to Collaborate on Sodium Cooled Fast Reactors Generation IV International Forum Signs Agreement to Collaborate on Sodium Cooled Fast Reactors February 17, 2006 - 11:58am Addthis FUKUI , JAPAN - The Department of Energy today announced that the United States signed a sodium-cooled fast reactor systems arrangement with France and Japan, providing the framework for collaboration among these countries on the research and development of these advanced nuclear reactors. The signing of the agreement took place on February 16, 2006. This arrangement will support the development of technologies associated with the U.S.-led Global Nuclear Energy Partnership (GNEP), announced earlier this month by Secretary of Energy Samuel W. Bodman. GNEP is a

446

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Federal - June 2012 Federal - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Federal - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Federal Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) DOE (Federal) Operational Readiness Review (D-ORR). The review was performed by the HSS Office of Safety and Emergency Management Evaluations and was intended to assess the effectiveness of the CORR process as implemented for the SBWTP-IWTU. This review also provides additional data regarding

447

Method for the generation of variable density metal vapors which bypasses the liquidus phase  

DOE Patents (OSTI)

The present invention provides a method for producing a metal vapor that includes the steps of combining a metal and graphite in a vessel to form a mixture; heating the mixture to a first temperature in an argon gas atmosphere to form a metal carbide; maintaining the first temperature for a period of time; heating the metal carbide to a second temperature to form a metal vapor; withdrawing the metal vapor and the argon gas from the vessel; and separating the metal vapor from the argon gas. Metal vapors made using this method can be used to produce uniform powders of the metal oxide that have narrow size distribution and high purity.

Kunnmann, Walter (Stony Brook, NY); Larese, John Z. (Rocky Point, NY)

2001-01-01T23:59:59.000Z

448

Numerical Methodology to Evaluate Fast Reactor Sodium Combustion  

SciTech Connect

In the present study, a numerical methodology for sodium combustion has been developed for the safety evaluation of a liquid-metal-cooled fast reactor. The methodology includes a fast-running zone model computer program for safety evaluation, a field model program for multidimensional thermal hydraulics, and a chemical reaction analysis program based on chemical equilibrium theory. Two recently performed experiments have been analyzed using the computer programs, and the numerical results are in good agreement with the experiments. Although sodium combustion is a complex phenomenon, use of these computer programs gives better understanding of the coupled thermal hydraulics and chemical reaction.

Yamaguchi, Akira; Takata, Takashi; Okano, Yasushi [Japan Nuclear Cycle Development Institute (Japan)

2001-12-15T23:59:59.000Z

449

The magnesium nutrition of cotton as influenced by sodium  

E-Print Network (OSTI)

1964 Major Subject. Plant Physic logy THE MAGNESIUM NUTRITION OF COTTON AS INFLUENCED BY SODIUM A Thesis By MERVYN M. THENABADU Approved as to style and content by: Chairman of Commi. e Nun Head of Department Member Mem, er Member Member... REVIEW OF LITERATURE (a) Sodium as a plant nutrient (b) I'he role of magnesium in plant nutrition MATERIALS AND METHODS RESUL:S DISCUSSION 13 21 24 (a) The effect of treatments on grcwth and reproduction (b) The effect of treatments on the ccr...

Thenabadu, Mervyn Wellesly

2012-06-07T23:59:59.000Z

450

Aluminum Zintl anion moieties within sodium aluminum clusters  

SciTech Connect

Through a synergetic combination of anion photoelectron spectroscopy and density functional theory based calculations, we have established that aluminum moieties within selected sodium-aluminum clusters are Zintl anions. Sodiumaluminum cluster anions, Na{sub m}Al{sub n}{sup ?}, were generated in a pulsed arc discharge source. After mass selection, their photoelectron spectra were measured by a magnetic bottle, electron energy analyzer. Calculations on a select sub-set of stoichiometries provided geometric structures and full charge analyses for both cluster anions and their neutral cluster counterparts, as well as photodetachment transition energies (stick spectra), and fragment molecular orbital based correlation diagrams.

Wang, Haopeng; Zhang, Xinxing; Ko, Yeon Jae; Grubisic, Andrej; Li, Xiang; Gantefr, Gerd; Bowen, Kit H., E-mail: AKandalam@wcupa.edu, E-mail: kiran@mcneese.edu, E-mail: kbowen@jhu.edu [Department of Chemistry, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Schnckel, Hansgeorg [Institute of Inorganic Chemistry, Karlsruhe Institute of Technology, 76128 Karlsruhe (Germany)] [Institute of Inorganic Chemistry, Karlsruhe Institute of Technology, 76128 Karlsruhe (Germany); Eichhorn, Bryan W. [Department of Chemistry, University of Maryland at College Park, College Park, Maryland 20742 (United States)] [Department of Chemistry, University of Maryland at College Park, College Park, Maryland 20742 (United States); Lee, Mal-Soon; Jena, P. [Department of Physics, Virginia Commonwealth University, Richmond, Virginia 23284 (United States)] [Department of Physics, Virginia Commonwealth University, Richmond, Virginia 23284 (United States); Kandalam, Anil K., E-mail: AKandalam@wcupa.edu, E-mail: kiran@mcneese.edu, E-mail: kbowen@jhu.edu [Department of Physics, West Chester University of Pennsylvania, West Chester, Pennsylvania 19383 (United States); Kiran, Boggavarapu, E-mail: AKandalam@wcupa.edu, E-mail: kiran@mcneese.edu, E-mail: kbowen@jhu.edu [Department of Chemistry, McNeese State University, Lake Charles, Louisiana 70609 (United States)] [Department of Chemistry, McNeese State University, Lake Charles, Louisiana 70609 (United States)

2014-02-07T23:59:59.000Z

451

Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mokapu Penninsula Area (Thomas, 1986) Mokapu Penninsula Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) Exploration Activity Details Location Mokapu Penninsula Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The high degree of cultural activity (e.g. residential areas, streets, jet runways, etc.) on Mokapu both limited the extent of the soil geochemical surveys performed and rendered their interpretation much more difficult. Soil mercury concentrations and radon emanometry data on the peninsula showed a few localized high values (Figs 13, 14), but no consistent correlation between the anomalous zones and geologic features could be

452

Detonation wave driven by condensation of supersaturated carbon vapor  

Science Journals Connector (OSTI)

An experimental observation of a detonation wave driven by the energy of condensation of supersaturated carbon vapor is reported. The carbon vapor was formed by the thermal decay of unstable carbon suboxide C3O2 behind shock waves in mixtures containing 1030% C3O2 in Ar. In the mixture 10% C3O2+Ar the insufficient heat release resulted in a regime of overdriven detonation. In the mixture 20% C3O2+Ar measured values of the pressure and wave velocity coincident with calculated Chapman-Jouguet parameters were attained. In the richest mixture 30% C3O2+Ar an excess heat release caused the slowing down of the condensation rate and the regime of underdriven detonation was observed.

A. Emelianov; A. Eremin; V. Fortov; H. Jander; A. Makeich; H. Gg. Wagner

2009-03-10T23:59:59.000Z

453

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents (OSTI)

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (approximately 1100.degree.-1300.degree. C.) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20-50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Brian, Riley (Willimantic, CT); Szreders, Bernard E. (Oakdale, CT)

1989-01-01T23:59:59.000Z

454

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents (OSTI)

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (/approximately/1100/degree/ /minus/ 1300/degree/C) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20--50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Riley, B.; Szreders, B.E.

1988-04-26T23:59:59.000Z

455

Specific Mass Estimates for A Vapor Core Reactor With MHD  

SciTech Connect

This study investigated the development of a system concept for space power generation and nuclear electric propulsion based on a vapor core reactor (VCR) with magnetohydrodynamic (MHD) power conversion system, coupled to a magnetoplasma-dynamic (MPD) thruster. The VCR is a liquid-vapor core reactor concept operating with metallic uranium or uranium tetrafluoride (UF{sub 4}) vapor as the fissioning fuel and alkali metals or their fluorides as working fluid in a closed Rankine cycle with MHD energy conversion. Gaseous and liquid-vapor core reactors can potentially provide the highest reactor and cycle temperature among all existing or proposed fission reactor designs. This unique feature makes this reactor concept a very natural and attractive candidate for very high power (10 to 1000 MWe) and low specific mass (0.4 to 5 kg/kWe) nuclear electric propulsion (NEP) applications since the MHD output could be coupled with minimal power conditioning to MPD thrusters or other types of thruster for producing thrust at very high specific impulse (I{sub sp} 1500 to 10,000 s). The exceptional specific mass performance of an optimized VCRMHD- NEP system could lead to a dramatic reduction in the cost and duration of manned or robotic interplanetary as well as interstellar missions. The VCR-MHD-NEP system could enable very efficient Mars cargo transfers or short (<8 month) Mars round trips with less initial mass in low Earth orbit (IMLEO). The system could also enable highly efficient lunar cargo transfer and rapid missions to other destinations throughout the solar system. (authors)

Knight, Travis; Smith, Blair; Anghaie, Samim [Innovative Nuclear Space Power and Propulsion Institute (INSPI), PO Box 116502, University of Florida, Gainesville, FL 32611-6502 (United States)

2002-07-01T23:59:59.000Z

456

Heat Recovery in Distillation by Mechanical Vapor Recompression  

E-Print Network (OSTI)

be classified generally into two types,.aerodynamic and positive displacement (Figure 5). Among the various types of compressors, centrifugal, reciprocating, lobe and screw have been used for vapor recompression. I AXIAL AERODYNAMIC I I CENTRIFUGAL I... speeds of centri fugal compressors make them highly susceptible to erosion from entrained liquid droplets. This ero sion can reduce the efficiency and cause dynamic instability from rotor imbalance and mechanical failure. Next, it is important...

Becker, F. E.; Zakak, A. I.

457

High average power magnetic modulator for metal vapor lasers  

DOE Patents (OSTI)

A three-stage magnetic modulator utilizing magnetic pulse compression designed to provide a 60 kV pulse to a copper vapor laser at a 4.5 kHz repetition rate is disclosed. This modulator operates at 34 kW input power. The circuit includes a step up auto transformer and utilizes a rod and plate stack construction technique to achieve a high packing factor.

Ball, Don G. (Livermore, CA); Birx, Daniel L. (Oakley, CA); Cook, Edward G. (Livermore, CA); Miller, John L. (Livermore, CA)

1994-01-01T23:59:59.000Z

458

Methanol vaporization and injection system for internal combustion engine  

SciTech Connect

An engine equipped with an alcohol vaporization injection system operates as a four stroke cycle diesel engine that transfers the heat of exiting exhaust gases and cylinder head walls to the fuel. The engine runs on alcohol. The alcohol becomes vaporized and its pressure is high enough so that when a valve is opened between the high pressure fuel line and the combustion chamber (when it is at the peak of its compression ratio) enough alcohol will enter the combustion chamber to allow proper combustion. The overall advantages to this type of alcohol vaporization injection system is that it adds relatively few new mechanisms to the spark ignition four cycle internal combustion engine to enable it to operate as a diesel engine with a high thermal efficiency. This alcohol injection system exploits the engine's need for greater volumes of alcohol caused by the alcohol's relatively low heat of combustion (When compared to gasoline) by using this greater volume of fuel to return greater quantities of heat back to the engine to a much greater degree than other fuels can.

Bayley, R.I.

1980-05-06T23:59:59.000Z

459

Program plan for the resolution of tank vapor issues  

SciTech Connect

Since 1987, workers at the Hanford Site waste tank farms in Richland, Washington, have reported strong odors emanating from the large, underground high-level radioactive waste storage tanks. Some of these workers have complained of symptoms (e.g., headaches, nausea) related to the odors. In 1992, the U.S. Department of Energy, which manages the Hanford Site, and Westinghouse Hanford Company determined that the vapor emissions coming from the tanks had not been adequately characterized and represented a potential health risk to workers in the immediate vicinity of the tanks. At that time, workers in certain areas of the tank farms were required to use full-face, supplied-breathing-air masks to reduce their exposure to the fugitive emissions. While use of supplied breathing air reduced the health risks associated with the fugitive emissions, it introduced other health and safety risks (e.g., reduced field of vision, air-line tripping hazards, and heat stress). In 1992, an aggressive program was established to assure proper worker protection while reducing the use of supplied breathing air. This program focuses on characterization of vapors inside the tanks and industrial hygiene monitoring in the tank farms. If chemical filtration systems for mitigation of fugitive emissions are deemed necessary, the program will also oversee their design and installation. This document presents the plans for and approach to resolving the Hanford Site high-level waste tank vapor concerns. It is sponsored by the Department of Energy Office of Environmental Restoration and Waste Management.

Osborne, J.W.; Huckaby, J.L.

1994-05-01T23:59:59.000Z

460

Ion Recognition Approach to Volume Reduction of Alkaline Tank Waste by Separation and Recycle of Sodium Hydroxide and Sodium Nitrate  

SciTech Connect

This research has focused on new liquid-liquid extraction chemistry applicable to separation of major sodium salts from alkaline tank waste. It was the overall goal to provide the scientific foundation upon which the feasibility of liquid-liquid extraction chemistry for bulk reduction of the volume of tank waste can be evaluated. Sodium hydroxide represented the initial test case and primary focus. It is a primary component of the waste1 and has the most value for recycle. A full explanation of the relevance of this research to USDOE Environmental Management needs will be given in the Relevance, Impact, and Technology Transfer section below. It should be noted that this effort was predicated on the need for sodium removal primarily from low-activity waste, whereas evolving needs have shifted attention to volume reduction of the high-activity waste. The results of the research to date apply to both applications, though treatment of high-activity wastes raises new questions that will be addressed in the renewal period. Toward understanding the extractive chemistry of sodium hydroxide and other sodium salts, it was the intent to identify candidate extractants and determine their applicable basic properties regarding selectivity, efficiency, speciation, and structure. A hierarchical strategy was to be employed in which the type of liquid-liquid-extraction system varied in sophistication from simple, single-component solvents to solvents containing designer host molecules. As an aid in directing this investigation toward addressing the fundamental questions having the most value, a conceptualization of an ideal process was advanced. Accordingly, achieving adequate selectivity for sodium hydroxide represented a primary goal, but this result is worthwhile for waste applications only if certain conditions are met.

Moyer, Bruce A.; Marchand, Alan P.; Bonnesen, Peter V.; Bryan, Jeffrey C.; Haverlock, Tamara J.

2002-03-30T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

The influence of prestrained metalorganic vapor phase epitaxial gallium-nitride templates on hydride vapor phase epitaxial growth  

Science Journals Connector (OSTI)

We have varied the strain situation in metalorganic vapor phase epitaxial (MOVPE) grown gallium-nitride (GaN) by exchanging the nucleation layer and by inserting a submono-Si x N y -interlayer in the first few hundred nanometers of growth on sapphire substrates. The influence on the MOVPE template and subsequent hydride vapor phase epitaxial (HVPE) growth could be shown by in-situ measurements of the sample curvature. Using the results of these investigations we have established a procedure to confine the curvature development in MOVPE and HVPE growth to a minimum. By increasing the layer thickness in HVPE we could create self-separated freestanding GaN layers with small remaining curvature.

2014-01-01T23:59:59.000Z

462

Tank 241-TX-118 headspace gas and vapor characterization results for samples collected in September 1994 and December 1994  

SciTech Connect

Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories

Huckaby, J.L. [Pacific Northwest Lab., Richland, WA (United States); Bratzel, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

1995-09-27T23:59:59.000Z

463

Bench-scale screening tests for a boiling sodium-potassium alloy solar receiver  

SciTech Connect

Bench-scale tests were carried out in support of the design of a second-generation 75-kW{sub t} reflux pool-boiler solar receiver. The receiver will be made from Haynes Alloy 230 and will contain the sodium-potassium alloy NaK-78. The bench-scale tests used quartz-lamp-heated boilers to screen candidate boiling-stabilization materials and methods at temperatures up to 750{degree}C. Candidates that provided stable boiling were tested for hot-restart behavior. Poor stability was obtained with single 1/4-inch diameter patches of powdered metal hot-press-sintered onto the wetted side of the heat-input area. Laser-drilled and electric-discharge-machined cavities in the heated surface also performed poorly. Small additions of xenon, and heated-surface tilt out of the vertical dramatically improved poor boiling stability; additions of helium or oxygen did not. The most stable boiling was obtained when the entire heat-input area was covered by a powdered-metal coating. The effect of heated-area size was assessed for one coating: at low incident fluxes, when even this coating performed poorly, increasing the heated-area size markedly improved boiling stability. Good hot-restart behavior was not observed with any candidate, although results were significantly better with added xenon in a boiler shortened from 3 to 2 feet. In addition to the screening tests, flash-radiography imaging of metal-vapor bubbles during boiling was attempted. Contrary to the Cole-Rohsenow correlation, these bubble-size estimates did not vary with pressure; instead they were constant, consistent with the only other alkali metal measurements, but about 1/2 their size.

Moreno, J.B.; Moss, T.A.

1993-06-01T23:59:59.000Z

464

Multiple reheat helium Brayton cycles for sodium fast reactors  

SciTech Connect

Sodium fast reactors (SFR) traditionally adopt the steam Rankine cycle for power conversion. The resulting potential for water-sodium reaction remains a continuing concern which at least partly delays the SFR technology commercialization and is a contributor to higher capital cost. Supercritical CO2 provides an alternative, but is also capable of sustaining energetic chemical reactions with sodium. Recent development on advanced inert-gas Brayton cycles could potentially solve this compatibility issue, increase thermal efficiency, and bring down the capital cost close to light water reactors. In this paper, helium Brayton cycles with multiple reheat and intercooling states are presented for SFRs with reactor outlet temperatures in the range of 510C to 650C. The resulting thermal efficiencies range from 39% and 47%, which is comparable with supercritical recompression CO2 cycles (SCO2 cycle). A systematic comparison between multiple reheat helium Brayton cycle and the SCO2 cycle is given, considering compatibility issues, plant site cooling temperature effect on plant efficiency, full plant cost optimization, and other important factors. The study indicates that the multiple reheat helium cycle is the preferred choice over SCO2 cycle for sodium fast reactors.

Haihua Zhao; Per F. Peterson

2008-07-01T23:59:59.000Z

465

FATE OF INGESTED SODIUM BICARBONATE IN THE FOWL  

E-Print Network (OSTI)

. 100 calcium while rations 3 and4contained 3.85 p. 100 calcium. Sodium bicarbonate was added at a level. The duodenum was entered at the top of the loop and the electrode tip immersed its full length down the posterior side of the loop. The #12;mid-intestinal reading was taken with the incision at approximately

Paris-Sud XI, Université de

466

Process for making boron nitride using sodium cyanide and boron  

DOE Patents (OSTI)

This a very simple process for making boron nitride by mixing sodium cyanide and boron phosphate and heating the mixture in an inert atmosphere until a reaction takes place. The product is a white powder of boron nitride that can be used in applications that require compounds that are stable at high temperatures and that exhibit high electrical resistance.

Bamberger, Carlos E. (Oak Ridge, TN)

1990-01-01T23:59:59.000Z

467

Method of Manufacturing Micro-Disperse Particles of Sodium Borohydride  

DOE Patents (OSTI)

A compact solid source of hydrogen gas, where the gas is generated by contacting water with micro-disperse particles of sodium borohydride in the presence of a catalyst, such as cobalt or ruthenium. The micro-disperse particles can have a substantially uniform diameter of 1-10 microns, and preferably about 3-5 microns. Ruthenium or cobalt catalytic nanoparticles can be incorporated in the micro-disperse particles of sodium borohydride, which allows a rapid and complete reaction to occur without the problems associated with caking and scaling of the surface by the reactant product sodium metaborate. A closed loop water management system can be used to recycle wastewater from a PEM fuel cell to supply water for reacting with the micro-disperse particles of sodium borohydride in a compact hydrogen gas generator. Capillary forces can wick water from a water reservoir into a packed bed of micro-disperse fuel particles, eliminating the need for using an active pump.

Kravitz, Stanley H. (Placitas, NM); Hecht, Andrew M. (Sandia Park, NM); Sylwester. Alan P. (Albuquerque, NM); Bell, Nelson S. (Albuquerque, NM)

2008-09-23T23:59:59.000Z

468

Method of generating hydrogen gas from sodium borohydride  

DOE Patents (OSTI)

A compact solid source of hydrogen gas, where the gas is generated by contacting water with micro-disperse particles of sodium borohydride in the presence of a catalyst, such as cobalt or ruthenium. The micro-disperse particles can have a substantially uniform diameter of 1-10 microns, and preferably about 3-5 microns. Ruthenium or cobalt catalytic nanoparticles can be incorporated in the micro-disperse particles of sodium borohydride, which allows a rapid and complete reaction to occur without the problems associated with caking and scaling of the surface by the reactant product sodium metaborate. A closed loop water management system can be used to recycle wastewater from a PEM fuel cell to supply water for reacting with the micro-disperse particles of sodium borohydride in a compact hydrogen gas generator. Capillary forces can wick water from a water reservoir into a packed bed of micro-disperse fuel particles, eliminating the need for using an active pump.

Kravitz, Stanley H. (Placitas, NM); Hecht, Andrew M. (Sandia Park, NM); Sylwester, Alan P. (Albuquerque, NM); Bell, Nelson S. (Albuquerque, NM)

2007-12-11T23:59:59.000Z

469

Headspace vapor characterization of Hanford Waste Tank 241-T-110: Results from samples collected on August 31, 1995. Tank Vapor Characterization Project  

SciTech Connect

This report describes the results of vapor samples taken from the headspace of waste storage tank 241-T-110 (Tank T-110) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Vapor Sampling and Analysis Plan{close_quotes}, and the sample job was designated S5056. Samples were collected by WHC on August 31, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace.

McVeety, B.D.; Thomas, B.L.; Evans, J.C. [and others

1996-05-01T23:59:59.000Z

470

Final Report for ARM Project Measuring 4-D Water Vapor Fields with GPS  

SciTech Connect

Water vapor is a primary element in the Earths climate system. Atmospheric water vapor is central to cloud processes, radiation transfer, and the hydrological cycle. Using funding from Department of Energy (DOE) grant DE-FG03-02ER63327, the University Corporation for Atmospheric Research (UCAR) developed new observational techniques to measure atmospheric water vapor and applied these techniques to measure four dimensional water vapor fields throughout the United States Southern Great Plains region. This report summarizes the development of a new observation from ground based Global Positioning System (GPS) stations called Slant Water Vapor (SW) and its utilization in retrieving four dimensional water vapor fields. The SW observation represents the integrated amount of water vapor between a GPS station and a transmitting satellite. SW observations provide improved temporal and spatial sampling of the atmosphere when compared to column-integrated quantities such as preciptitable water vapor (PW). Under funding from the DOE Atmospheric Radiation Measurement (ARM) program, GPS networks in the Southern Great Plains (SGP) region were deployed to retrieve SW to improve the characterization of water vapor throughout the region. These observations were used to estimate four dimensional water vapor fields using tomographic approaches and through assimilation into the MM5 numerical weather model.

Braun, John

2006-02-06T23:59:59.000Z

471

Chemistry of Petroleum Crude Oil Deposits: Sodium Naphthenates 2009 NHMFL Science Highlight for NSF  

E-Print Network (OSTI)

Chemistry of Petroleum Crude Oil Deposits: Sodium Naphthenates 2009 NHMFL Science Highlight for NSF-355. Chemistry of Petroleum Crude Oil Deposits: Sodium Naphthenates 2009 NHMFL Science Highlight for NSF DMR

Weston, Ken

472

Structural basis for the transformation pathways of the sodium naproxen anhydrate-hydrate system  

Science Journals Connector (OSTI)

Relationships between the crystal structures of two polymorphs of sodium naproxen dihydrate and its monohydrate and anhydrate phases provide a basis to rationalize the observed transformation pathways in the sodium (S)-naproxen anhydrate-hydrate system.

Bond, A.D.

2014-08-20T23:59:59.000Z

473

SnSb@carbon nanocable anchored on graphene sheets for sodium ion batteries  

Science Journals Connector (OSTI)

The development of materials with unique nanostructures is an effective strategy for the improvement of sodium storage in sodium ion batteries to achieve stable cycling performance and good ... , SnSbcore/carbon-...

Li Li; Kuok Hau Seng; Dan Li; Yongyao Xia; Hua Kun Liu; Zaiping Guo

2014-10-01T23:59:59.000Z

474

Go No-Go Recommendation for Sodium Borohydride for On-Board Vehicular Hydrogen Storage  

Fuel Cell Technologies Publication and Product Library (EERE)

Independent review panel recommendation for go/no go decision on use of hydrolysis of sodium borohydride for hydrogen storage.

475

Cannelton Utilities | Open Energy Information  

Open Energy Info (EERE)

Cannelton Utilities Cannelton Utilities Jump to: navigation, search Name Cannelton Utilities Place Indiana Utility Id 2964 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting: Murcury Vapor Light, 175 Watt Lighting Rate 1: Residential Residential Rate 2: Multi-Phase Commercial Rate 2: Single Phase Commercial Rate 3: Industrial Phase II Residential Rate 3: Industrial phase I Industrial Street Lighting: Decorative Metal Halide, 175 Watt Lighting Street Lighting: High Pressure Sodium, 100 Watt Lighting

476

Effect of sodium montmorillonite nanoclay on the water absorbency and cationic dye removal of carrageenan-based nanocomposite superabsorbents  

Science Journals Connector (OSTI)

Nanocomposite superabsorbents were synthesized by simultaneously solution copolymerization of acrylamide (AAm) and sodium acrylate (Na-AA) in the presence of carrageenan biopolymer and sodium montmorillonite (Na-...

Gholam Reza Mahdavinia; Bakhshali Massoumi; Karim Jalili

2012-08-01T23:59:59.000Z

477

Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Salt Wells Area (Henkle, Et Al., 2005) Exploration Activity Details Location Salt Wells Area Exploration Technique Mercury Vapor Activity Date - 2005 Usefulness useful DOE-funding Unknown Exploration Basis Adsorbed mercury soil geochemical surveys and radiometric geophysical surveys were carried out in conjunction with geologic mapping to test the application of these ground-based techniques to geothermal exploration at three prospects in Nevada by Henkle Jr. et al. in 2005. Mercury soil vapor surveys were not widely used in geothermal exploration in the western US at the time, although the association of mercury vapors with geothermal

478

MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN  

NLE Websites -- All DOE Office Websites (Extended Search)

MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN MEASUREMENTS AND RETRIEVALS FROM A NEW 183-GHz WATER VAPOR RADIOMETER IN THE ARCTIC Cadeddu, Maria Argonne National Laboratory Category: Instruments A new G-band (183 GHz) vapor radiometer (GVR), developed and built by Prosensing Inc. (http://www.prosensing.com), was deployed in Barrow, Alaska, in April 2005. The radiometer was deployed as part of the ongoing Atmospheric Radiation Measurement (ARM) program's effort to improve water vapor retrievals in the cold, dry Arctic environment. The instrument measures brightness temperatures from four double sideband channels centered at 1, 3, 7, and 14 GHz from the 183.31-GHz water vapor line. Atmospheric emission in this spectral region is primarily due to water vapor, with some influence from liquid water. The GVR will remain in Barrow

479

Chemical vapor deposition of amorphous semiconductor films. Final subcontract report  

SciTech Connect

Chemical vapor deposition (CVD) from higher order silanes has been studied for fabricating amorphous hydrogenated silicon thin-film solar cells. Intrinsic and doped a-Si:H films were deposited in a reduced-pressure, tubular-flow reactor, using disilane feed-gas. Conditions for depositing intrinsic films at growth rates up to 10 A/s were identified. Electrical and optical properties, including dark conductivity, photoconductivity, activation energy, optical absorption, band-gap and sub-band-gap absorption properties of CVD intrinsic material were characterized. Parameter space for depositing intrinsic and doped films, suitable for device analysis, was identified.

Rocheleau, R.E.

1984-12-01T23:59:59.000Z

480

A thermoacoustic oscillator powered by vaporized water and ethanol  

Science Journals Connector (OSTI)

We measure the temperature difference required to drive a thermoacoustic oscillator containing air water vapor and liquid water as the working fluids. The oscillator is composed of a large tube containing an array of narrow tubes connected at one end to a tank of liquid water. When the water is heated the temperature difference across the tube array increases until thermoacoustic oscillations occur. The temperature difference at the onset of oscillation is measured to be 56 ? C significantly smaller (by ? 200 ? C ) than the temperature measured when the tank is filled with dry air instead of water. The temperature difference can be further reduced to 47 ? C by using ethanol instead of water.

Daisuke Noda; Yuki Ueda

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Io - Are vapor explosions responsible for the 5-micron outbursts  

SciTech Connect

It is proposed that a vapor explosion of a submerged pool of liquid sulfur will remove the crust overlying an area of about 50-km diam. Thermal radiation from the exposed liquid sulfur pool with a surface temperature of 600 K is then presumed to be responsible for the 5-micron outbursts that have been observed. The explosive volcanoes are expected to leave black sulfur calderas, which are, indeed, found on the surface. The 5-micron outburst observed by Sinton (1980), on June 11, 1979 (UT), is identified with a new caldera found on Voyager 2 photographs but which had not been present on Voyager 1 pictures.

Sinton, W.M.

1980-01-01T23:59:59.000Z

482

Optical waveguides in SBN by zinc vapor diffusion  

E-Print Network (OSTI)

at 600'C for a 12. 5 i1m Wide 1000'C Zinc Vapor Diffused SBN:60 Waveguide Measured at X = 0. 81 pm. IV. SBN:60 Amplitude Modulator Results . . . . . V. SBN:60 Mach-Zehnder Interferometer Results. . . . VI. Voltage-Length Product Comparison...: (a) extraordinary (TM), (b) 1. 5 x ordinary (TE). 12. Surface damage on SBN:60 diffused at 1000'C with an SiOz diffusion mask. 13. Zinc in-diffusion in SBN:60 25 . . . . . 26 . . . . . 27 . . . . . 28 29 14. Barium out-diffuison in SBN:60...

Quinn, Jeffrey Dale

1991-01-01T23:59:59.000Z

483

Combustion chemical vapor deposited coatings for thermal barrier coating systems  

SciTech Connect

The new deposition process, combustion chemical vapor deposition, shows a great deal of promise in the area of thermal barrier coating systems. This technique produces dense, adherent coatings, and does not require a reaction chamber. Coatings can therefore be applied in the open atmosphere. The process is potentially suitable for producing high quality CVD coatings for use as interlayers between the bond coat and thermal barrier coating, and/or as overlayers, on top of thermal barrier coatings. In this report, the evaluation of alumina and ceria coatings on a nickel-chromium alloy is described.

Hampikian, J.M.; Carter, W.B. [Georgia Institute of Technology, Atlanta, GA (United States). School of Materials Science and Engineering

1995-12-31T23:59:59.000Z

484

Unusual thermopower of inhomogeneous graphene grown by chemical vapor deposition  

SciTech Connect

We report on thermopower (TEP) and resistance measurements of inhomogeneous graphene grown by chemical vapor deposition (CVD). Unlike the conventional resistance of pristine graphene, the gate-dependent TEP shows a large electron-hole asymmetry. This can be accounted for by inhomogeneity of the CVD-graphene where individual graphene regions contribute with different TEPs. At the high magnetic field and low temperature, the TEP has large fluctuations near the Dirac point associated with the disorder in the CVD-graphene. TEP measurements reveal additional characteristics of CVD-graphene, which are difficult to obtain from the measurement of resistance alone.

Nam, Youngwoo, E-mail: youngwoo.nam@chalmers.se [Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of); Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Sun, Jie; Lindvall, Niclas; Yurgens, August [Department of Microtechnology and Nanoscience, Chalmers University of Technology, SE-412 96 Gothenburg (Sweden); Jae Yang, Seung; Rae Park, Chong [Department of Materials Science and Engineering, Seoul National University, Seoul 151-747 (Korea, Republic of); Woo Park, Yung [Department of Physics and Astronomy, Seoul National University, Seoul 151-747 (Korea, Republic of)

2014-01-13T23:59:59.000Z

485

Dosimeter for monitoring vapors and aerosols of organic compounds  

DOE Patents (OSTI)

A dosimeter is provided for collecting and detecting vapors and aerosols of organic compounds. The dosimeter comprises a lightweight, passive device that can be conveniently worn by a person as a badge or placed at a stationary location. The dosimeter includes a sample collector comprising a porous web treated with a chemical for inducing molecular displacement and enhancing phosphorescence. Compounds are collected onto the web by molecular diffusion. The web also serves as the sample medium for detecting the compounds by a room temperature phosphorescence technique. 7 figs.

Vo-Dinh, T.

1987-07-14T23:59:59.000Z

486

The Prospects of Alternatives to Vapor Compression Technology for Space Cooling and Food Refrigeration Applications  

SciTech Connect

Five alternatives to vapor compression technology were qualitatively evaluated to determine their prospects for being better than vapor compression for space cooling and food refrigeration applications. The results of the assessment are summarized in the report. Overall, thermoacoustic and magnetic technologies were judged to have the best prospects for competing with vapor compression technology, with thermotunneling, thermoelectric, and thermionic technologies trailing behind in that order.

Brown, Daryl R.; Dirks, James A.; Fernandez, Nicholas; Stout, Tyson E.

2010-03-31T23:59:59.000Z

487

A thermodynamics based analysis of exergy destruction in vapor compression cycle systems.  

E-Print Network (OSTI)

??In the last few decades, vapor-compression cycle systems (VCSs) have undergone many advances in actuation, allowing for variable aperture valves, variable speed compressors, and variable (more)

Kania, Megan

2013-01-01T23:59:59.000Z

488

Synthesis and Characterization of Magnetic Nanowires Prepared by Chemical Vapor Deposition.  

E-Print Network (OSTI)

??Various metal silicide and germanide magnetic nanowires were synthesized using a home-built CVD [chemical vapor deposition] system. The morphology, composition, and magnetic properties of the (more)

Tang, Siwei

2014-01-01T23:59:59.000Z

489

Liquid fuel vaporizer and combustion chamber having an adjustable thermal conductor  

DOE Patents (OSTI)

The efficiency and effectiveness of apparatuses for vaporizing and combusting liquid fuel can be improved using thermal conductors. For example, an apparatus having a liquid fuel vaporizer and a combustion chamber can be characterized by a thermal conductor that conducts heat from the combustion chamber to the vaporizer. The thermal conductor can be a movable member positioned at an insertion depth within the combustion chamber that corresponds to a rate of heat conduction from the combustion chamber to the vaporizer. The rate of heat conduction can, therefore, be adjusted by positioning the movable member at a different insertion depth.

Powell, Michael R; Whyatt, Greg A; Howe, Daniel T; Fountain, Matthew S

2014-03-04T23:59:59.000Z

490

Stable-Isotope Studies Of Rocks And Secondary Minerals In A Vapor...  

Open Energy Info (EERE)

Stable-Isotope Studies Of Rocks And Secondary Minerals In A Vapor-Dominated Hydrothermal System At The Geysers, Sonoma County, California Jump to: navigation, search GEOTHERMAL...

491

The Patuha geothermal system: a numerical model of a vapor-dominated system.  

E-Print Network (OSTI)

??The Patuha geothermal system is a vapor-dominated reservoir located about 40 kilometers southwest of Bandung on western Java, Indonesia. The geothermal system consists of a (more)

Schotanus, M.R.J.

2013-01-01T23:59:59.000Z

492

E-Print Network 3.0 - alkali atom vapor Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

a vapor cell magneto-optical trap. 1999 American... to the vacuum pumps or due to adsorption of the ... Source: Jin, Deborah - JILA, University of Colorado at Boulder...

493

Removal of hydrogen sulfide as ammonium sulfate from hydropyrolysis product vapors  

SciTech Connect

A system and method for processing biomass into hydrocarbon fuels that includes processing a biomass in a hydropyrolysis reactor resulting in hydrocarbon fuels and a process vapor stream and cooling the process vapor stream to a condensation temperature resulting in an aqueous stream. The aqueous stream is sent to a catalytic reactor where it is oxidized to obtain a product stream containing ammonia and ammonium sulfate. A resulting cooled product vapor stream includes non-condensable process vapors comprising H.sub.2, CH.sub.4, CO, CO.sub.2, ammonia and hydrogen sulfide.

Marker, Terry L; Felix, Larry G; Linck, Martin B; Roberts, Michael J

2014-10-14T23:59:59.000Z

494

Response of passive organic vapor dosimeters to a mixed gas exposure  

E-Print Network (OSTI)

of Advisory Comm1ttee: Dr. Richard B. Konzen The effects of the sampling order of two chemicals adsorbed onto a DuPont Pro-Tek Organic Vapor Dosimeters were investigated. The dosimeters were exposed to varying known concentrations of methyl methacrylate...-powered pump to draw a known volume of air through a charcoal packed tube. The charcoal adsorbs the organic vapors and separates the small amount of vapor from a large amount of air. The organic vapors are then desorbed and analyzed by means of gas...

Anderson, Scott Merritt

2012-06-07T23:59:59.000Z

495

Low-Cost, Modular Electrothermal Vaporization System for Inductively Coupled Plasma Atomic Emission Spectrometry  

Science Journals Connector (OSTI)

In this investigation, commercially available tungsten filaments were employed to electrothermally vaporize liquid samples prior to their introduction into an inductively coupled...

Levine, Keith; Wagner, Karl A; Jones, Bradley T

1998-01-01T23:59:59.000Z

496

E-Print Network 3.0 - atomic vapor deposited Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Articles Surfactant-Catalyzed Chemical Vapor Deposition of Copper Thin Films Eui Seong Hwang... and demonstrated for deposition of copper thin films from ... Source:...

497

E-Print Network 3.0 - acoustic wave vapor Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

(6). While previous systems have demonstrated success in chemical... striking visual identification of a range of ligating vapors (including alcohols, amines, ethers... ,...

498

Advanced Organic Vapor Cycles for Improving Thermal Conversion Efficiency in Renewable Energy Systems.  

E-Print Network (OSTI)

??The Organic Flash Cycle (OFC) is proposed as a vapor power cycle that could potentially increase power generation and improve the utilization efficiency of renewable (more)

Ho, Tony

2012-01-01T23:59:59.000Z

499

Towards improved spinnability of chemical vapor deposition generated multi-walled carbon nanotubes  

E-Print Network (OSTI)

P. J. F. 1999 Carbon nanotubes and related structures: newof vapor grown carbon nanotubes and single wall nanotubes, Eto Carbon Materials in Carbon Nanotubes: Preparation and

McKee, Gregg Sturdivant Burke

2008-01-01T23:59:59.000Z

500

Opals infiltrated with a stimuli-responsive hydrogel for ethanol vapor sensing  

Science Journals Connector (OSTI)

We report on a novel class of optical materials for ethanol vapor sensing, based on polystyrene opals infiltrated with an innovative stimuli-responsive hydrogel. We describe the...

Pernice, Riccardo; Adamo, Gabriele; Stivala, Salvatore; Parisi, Antonino; Busacca, Alessandro C; Spigolon, Dario; Sabatino, Maria Antonietta; DAcquisto, Leonardo; Dispenza, Clelia

2013-01-01T23:59:59.000Z