Powered by Deep Web Technologies
Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

High intensity discharge 400-watt sodium ballast. Phase I. Final report  

SciTech Connect

The results of a research and development program directed toward design, test, and evaluation of energy efficient High Intensity Discharge (HID) Solid State 400-Watt Ballast lighting system are reported. Phase I of the project which was designed to modify the existing Datapower ballast to LBL configuration, measure performance characteristics, and compare efficiency with a core/coil ballast including energy loss analysis is covered. In addition, Datapower was tasked to build six (6) prototype 400-Watt High Pressure Sodium Ballasts for verification tests by an independent test facility and follow-on performance and life tests at LBL.

Felper, G.

1980-06-01T23:59:59.000Z

2

Interaction of sodium vapor and graphite studied by ...  

Science Conference Proceedings (OSTI)

The kinetics of the reaction between graphite and sodium vapor is analyzed with support ... High temperature compression test to determine the anode paste...

3

Energy-efficient H. I. D. solid-state ballast: Phase II final report. [150 watt high pressure sodium lamp  

SciTech Connect

The following report presents the results of Phase II, Development of Solid State 150 watt High Pressure Sodium Ballasts. Basically, the objectives of the development program were accomplished, i.e., greater than 90% efficiency, greater than 90% power factor, regulation equivalent to ferro-magnetic ballasts, and energy savings sufficient to warrant the further development of the solid-state HPS ballast for commercial production and marketing. 8 figs., 5 tabs.

1983-06-01T23:59:59.000Z

4

Investigation of a Sodium Vapor Compressor Jet for Nuclear Propulsion of Aircraft  

SciTech Connect

?Analysis indicates that, in order to achieve supersonic flight with nuclear powered aircraft, a reactor -power plant combination capable of operating at temperatures considerably in excess of current practice must be developed. It is pointed out that there exist two general avenues of approach toward the goal of attaining high temperature reactors and power plants. The first approach involves the continuation and augmentation of research along the lines pursued by the conventional turbo-jet engine manufacturer, namely a search for material coatings or materials that will retain structural strength in high temperature oxidizing atmospheres. The second approach seeks to take advantage of the peculiar characteristics of the compressor-jet engine that permit the operation of the high temperature components in a non-oxidizing atmosphere. The results of a preliminary design study of a supersonic aircraft powered by a high temperature sodium, liquid vapor compressor -jet engine are summarized. The analysis considered, in as much detail as was warranted by the limited experimental information available, the characteristics of the reactor, power plant and airframe involved in determining performance. This study has been conducted for the purpose of guiding future, long -t e r rn , research work along the lines of high temperature reactors and power plants for aircraft propulsion. The sodium vapor compressor -jet is not presented as an engine that is presently considered feasible nor is any attempt made to establish a time table for its development. ?The present status of reactor -power plant combinations of the type discussed in this report is such that the configurations presented and the thermodynamic requirements set forth are highly c onj ectural. However, in light of the promising results thus far obtained from very limited experimentation in the field of high temperature materials not subject to oxidizing atmospheres, it appears worthwhile to continue a research effort along these lines in the expectation of making high temperature, high performance aircraft a reality. This report is based upon studies conducted for the Atomic Energy Commission under Contract AT-40-l-GEN-1064. These studies were concluded on September 1, 1951, and were informally made available to the Aircraft Nuclear Propulsion Group at ORNL at that time.

Schwartz, H.

1953-06-25T23:59:59.000Z

5

Sodium  

SciTech Connect

Some of the properties of sodium are reviewed, particularly its properties which make it useful as a FBR coolant. The FFTF and other sodium research facilities at HEDL are described. (DLC)

1979-09-27T23:59:59.000Z

6

Definition: Watt | Open Energy Information  

Open Energy Info (EERE)

Watt Watt Jump to: navigation, search Dictionary.png Watt A unit of measure for power, which measures the rate of energy conversion; equal to one joule per second (or 1/746 horsepower); equivalent to one ampere under a pressure of one volt.[1][2] View on Wikipedia Wikipedia Definition The watt' is a derived unit of power in the International System of Units (SI), named after the Scottish engineer James Watt (1736-1819). The unit, defined as one joule per second, measures the rate of energy conversion or transfer. Also Known As W Related Terms Electricity, Power, Kilowatt References ↑ http://www.eia.gov/tools/glossary/index.cfm?id=W#watt ↑ http://needtoknow.nas.edu/energy/glossary/ Retri LikeLike UnlikeLike You like this.Sign Up to see what your friends like. eved from

7

PlotWatt | Open Energy Information  

Open Energy Info (EERE)

PlotWatt PlotWatt Jump to: navigation, search Tool Summary LAUNCH TOOL Name: PlotWatt Agency/Company /Organization: PlotWatt Sector: Energy Focus Area: Energy Efficiency Resource Type: Software/modeling tools User Interface: Mobile Device Website: plotwatt.com/ Country: United States Web Application Link: plotwatt.com/ Cost: Free OpenEI Keyword(s): Green Button Apps Northern America Language: English PlotWatt Screenshot References: PlotWatt[1]PlotWatt FAQ[2] Logo: PlotWatt PlotWatt helps you to save money and energy, instead of getting hit with high energy bills every month. PlotWatt shows you exactly where to save. Overview PlotWatt's algorithms analyze home energy consumption to figure out spending at the appliance level and figure out how to cost effectively save

8

WattQuiz | Open Energy Information  

Open Energy Info (EERE)

WattQuiz WattQuiz Jump to: navigation, search Tool Summary LAUNCH TOOL Name: WattQuiz Agency/Company /Organization: Genability Sector: Energy Focus Area: Energy Efficiency Resource Type: Software/modeling tools User Interface: Website Website: www.wattquiz.com/ Country: United States Web Application Link: www.wattquiz.com/ Cost: Free Northern America Language: English WattQuiz Screenshot References: Genability[1] NYC Open Data[2] Donors Choose[3] Logo: WattQuiz A social quiz on energy usage that donates proceeds to charity via DonorsChoose.org. Questions are powered by Genability APIs. Overview WattQuiz is a simple social quiz, a la freerice.com, that asks you questions and educates you about your energy. Correct answers generate watts that are donated to worthy charities via DonorsChoose.org!

9

Goodbye, Watts. Hello, LUMENS! | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Goodbye, Watts. Hello, LUMENS! Goodbye, Watts. Hello, LUMENS! Goodbye, Watts. Hello, LUMENS! May 17, 2012 - 2:21pm Addthis John Chu John Chu Communications Specialist with the Office of Energy Efficiency and Renewable Energy For years, I bought light bulbs based on watts, or energy use. Like many light bulb consumers, I looked for a traditional 40, 60, 75, or 100 watt incandescent bulb. Now that stores today carry more and more energy efficient lighting choices, I wanted to replace my old incandescents with new bulbs to save energy and money on my electricity bill. But in shopping for the right bulb, I came across a challenge in looking for bulbs based on watts. Since these newer bulbs use less energy, I found bulbs that use 8, 15, or 26 watts. The wattages are pretty close to each other, but the

10

Denver Watts to Water | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

Denver Watts to Water Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial...

11

Tennessee Nuclear Profile - Watts Bar Nuclear Plant  

U.S. Energy Information Administration (EIA) Indexed Site

Watts Bar Nuclear Plant" "Unit","Summer capacity (mw)","Net generation (thousand mwh)","Summer capacity factor (percent)","Type","Commercial operation date","License expiration...

12

MegaWatt Solar | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Name MegaWatt Solar Place North Carolina Sector Renewable Energy, Solar Product North Carolina-based, technology-centric renewable energy company...

13

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium light tubes are recycled. They are made from aluminum and metal. Aluminum is a silver-white metal and is very light in weight and strong. Because aluminum is ductile, it can be drawn into wires or pressed

Ungerleider, Leslie G.

14

Reducing Leaking Electricity to 1 Watt  

Science Conference Proceedings (OSTI)

In this study we examine some specific opportunities toreduce standby losses in electronic appliances. A review of powerconsumption levels for the major components responsible for standbyfunctions indicates that nearly all standby functions can be performedwith a total appliance standby power consumption of one watt or less. Wetherefore propose that standby losses be limited to one watt perappliance, a significant reduction from current levels for manyappliances. This target could be achieved with little or no extra cost tomanufacturers and could save over $2 billion in annual U.S. energy costs.Globally, a one-watt plan would lead to a significant reduction in carbonemissions.

Meier, A.K.; Huber, Wolfgang; Rosen, Karen

1998-08-01T23:59:59.000Z

15

Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear...

16

TerraWatt Power | Open Energy Information  

Open Energy Info (EERE)

TerraWatt Power TerraWatt Power Jump to: navigation, search Name TerraWatt Power Place Schenectady, New York Zip 12305-1036 Product American manufacturer of micro-inverters, subsidiary of Advanced Energy Conversion. Coordinates 42.81226°, -73.941026° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.81226,"lon":-73.941026,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

17

AstroWatt | Open Energy Information  

Open Energy Info (EERE)

AstroWatt AstroWatt Jump to: navigation, search Name AstroWatt Place Austin, Texas Sector Solar Product Texas-based venture backed company developing a proprietary solar cell technology. Coordinates 30.267605°, -97.742984° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.267605,"lon":-97.742984,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

18

AlphaWatt Ltd | Open Energy Information  

Open Energy Info (EERE)

AlphaWatt Ltd AlphaWatt Ltd Jump to: navigation, search Name AlphaWatt Ltd Place London, United Kingdom Zip EC1V 4PY Sector Solar Product Solar project developer, plans to become an independent power provider. Coordinates 51.506325°, -0.127144° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":51.506325,"lon":-0.127144,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

19

GlobalWatt Inc | Open Energy Information  

Open Energy Info (EERE)

GlobalWatt Inc GlobalWatt Inc Jump to: navigation, search Name GlobalWatt Inc Place Dover, Delaware Zip 19801 Product Shell company, once planned to float on AIM to raise money in order to acquire the business of semiconductor and/or PV manufacturing equipment suppliers. Coordinates 42.67954°, -88.110374° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.67954,"lon":-88.110374,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

20

WASTE TO WATTS Waste is a Resource!  

E-Print Network (OSTI)

WASTE TO WATTS Waste is a Resource! energy forum Case Studies from Estonia, Switzerland, Germany BREFs and their BATs Next Generation of Waste Fired Power Plants: Getting the most out of your trash Bossart,· ABB Waste-to-Energy Plants Edmund Fleck,· ESWET Marcel van Berlo,· Afval Energie Bedrijf From

Columbia University

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

PROGRAM TOPIC: GASIFICATION TECHNOLOGIES PREVENTING AGGLOMERATION PROBLEMS DURING GASIFICATION OF HIGH-SODIUM LIGNITE  

E-Print Network (OSTI)

Previous gasification studies have shown that sodium vapor released from high-sodium lignites can react with silica to form sticky sodium silicates. 1,2,3

Robert S. Dahlin; Johnny R. Dorminey; Southern Company Services; Wanwang Peng; Southern Company Services; Pannalal Vimalch; Southern Company Services

2008-01-01T23:59:59.000Z

22

Watts, Oklahoma: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Watts, Oklahoma: Energy Resources Watts, Oklahoma: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 36.1092487°, -94.5702202° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.1092487,"lon":-94.5702202,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

23

Shanghai Solar Watt Ltd | Open Energy Information  

Open Energy Info (EERE)

Solar Watt Ltd Solar Watt Ltd Jump to: navigation, search Name Shanghai Solar-Watt Ltd Place Shanghai, Shanghai Municipality, China Zip 200040 Sector Renewable Energy, Solar, Wind energy Product Providing photovoltaic systems, solar air heating systems, solar water pumping systems, wind energy systems (small), photovoltaic module manufacturing equipment and renewable energy system batteries. Coordinates 31.247709°, 121.472618° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":31.247709,"lon":121.472618,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

24

Specification for strontium-90 500-watt(e) radioisotopic thermoelectric generator. Final report  

DOE Green Energy (OSTI)

A conceptual design for a demonstration 500-watt(e) radioisotopic thermoelectric generator has been created for the Department of Energy. The design effort was divided into two tasks, viz., create a design specification for a capsule strength member that utilizes a standard Strontium-90 fluoride-filled WESF inner liner, and create a conceptual design for a 500-watt(e) RTG. Both tasks have been accomplished. The strength-member specification was designed to survive an external pressure of 24,500 psi and meet the requirements of special-form radioisotope heat sources. Therefore the capsule can, if desired, be licensed for domestic and international transport. The design for the RTG features a radioisotopic heat source, an array of nine capsules in a tungsten biological shield, four current-technology series-connected thermoelectric-conversion modules, low-conductivity thermal insulation, and a passive finned-housing radiator for waste-heat dissipation. The preliminary RTG specification formulated previous to contract award has been met or exceeded. The power source will generate the required power for the required service period at 28 volts dc with a conversion efficiency of 8%, provided the existing in-pool capsules at WESF meet the assumed thermal-inventory requirements.

Hammel, T.; Himes, J.; Lieberman, A.; McGrew, J.; Owings, D.; Schumann, F.

1983-04-01T23:59:59.000Z

25

Trico Electric Cooperative - SunWatts Incentive Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Trico Electric Cooperative - SunWatts Incentive Program Trico Electric Cooperative - SunWatts Incentive Program Trico Electric Cooperative - SunWatts Incentive Program < Back Eligibility Commercial Residential Savings Category Solar Buying & Making Electricity Heating & Cooling Water Heating Maximum Rebate PV systems 10 kW or smaller: 30% of the total system cost Program Info State Arizona Program Type Utility Rebate Program Rebate Amount PV systems 10 kW or smaller: $0.10/watt DC PV greater than 10 kW up to 1 MW: Performance-Based Incentive (competitive bid process) Solar water heaters: $0.40 per expected first year kWh savings Provider Trico Electric Cooperative, Inc. Through the SunWatts Program, Trico Electric Cooperative offers residential and business customers a rebate for installing photovoltaic (PV) systems

26

Kill-a-Watt Contest at UCF | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kill-a-Watt Contest at UCF Kill-a-Watt Contest at UCF Kill-a-Watt Contest at UCF April 2, 2010 - 5:16pm Addthis The University of Central Florida has created an innovative way to save energy and money on campus through a new dorm-based competition called "Kill-a-Watt". Students representing campus residence halls compete against each other to achieve energy savings and can receive up to $200 in scholarships. Watch how former DOE intern and current UCF DOE Campus Ambassador, Chris Castro, is spearheading this exciting effort and learn more about energy saving tips that students find useful like proper thermostat set points and reducing plug load. Read the DoE's press release about the video. Addthis Related Articles University of Central Florida Students' Energy Saving Work Showcased in New

27

Duncan Valley Electric Cooperative- SunWatts Rebate Program (Arizona)  

Energy.gov (U.S. Department of Energy (DOE))

Duncan Valley Electric Cooperative is providing rebates to for the purchase of renewable energy systems through its SunWatts program. Photovoltaic (PV) and wind energy systems 10 kilowatts (kW) or...

28

One watt initiative: A global effort to reduce leaking electricity  

E-Print Network (OSTI)

Watt when being OFF or on standby. The challenge may appearAction to Reduce Standby Power Waste of Electricalon www.iea.org/standby/ . 18 & 19 .01.99 Siderius Hans-Paul,

Meier, Alan K.; LeBot, Benoit

1999-01-01T23:59:59.000Z

29

Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington SUMMARY This EA evaluates the environmental impacts associated with the U.S. Department of Energy proposed action to conduct a lead test assembly program to confirm the viability of using a commercial light water reactor to produce tritium. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD July 22, 1997 EA-1210: Finding of No Significant Impact Lead Test Assembly Irradiation and Analysis Watts Bar Nuclear Plant, Tennessee and Hanford Site, Richland, Washington July 22, 1997 EA-1210: Final Environmental Assessment

30

VP 100: Retooling Michigan -- Yachts and Watts | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

VP 100: Retooling Michigan -- Yachts and Watts VP 100: Retooling Michigan -- Yachts and Watts VP 100: Retooling Michigan -- Yachts and Watts June 18, 2010 - 4:13pm Addthis Energetx Composites was able to purchase equipment such as this mold for utility-scale wind turbine blades thanks to a Recovery Act grant that matched the company’s $3.5 million investment. | Photo Courtesy of Energetx | Energetx Composites was able to purchase equipment such as this mold for utility-scale wind turbine blades thanks to a Recovery Act grant that matched the company's $3.5 million investment. | Photo Courtesy of Energetx | Joshua DeLung Near the eastern shore of Lake Michigan, there's a shift taking place. Tiara Yachts makes fiber composite structures for boats. Now the Holland, Mich.-based company is transforming part of its factory and using its 30

31

One watt initiative: A global effort to reduce leaking electricity  

SciTech Connect

Many domestic appliances and commercial equipment consume some electric power when they are switched off or not performing their primary purpose. The typical loss per appliance is low (from 1 to 25 W) but, when multiplied by the billions of appliances in houses and in commercial buildings, standby losses represent a significant fraction of total electricity use. Several initiatives to reduce standby losses have appeared in different parts of the world. One proposal, the 1-watt plan, seeks to harmonize these initiatives by establishing a single target for all appliances. This paper explains the background to the 1-watt plan, identifies some unresolved aspects, and gives some estimates of energy savings.

Meier, Alan K.; LeBot, Benoit

1999-05-30T23:59:59.000Z

32

Dealing with failed deregulation: what would price c. Watts do?  

SciTech Connect

There has been much thought given to ways that might fix deregulated markets, and there is still no agreement on the correct fix. The once-pseudonymous Price C. Watts thinks it is time to think seriously about ways to reregulate where deregulation has failed. Here are some steps to get us there. (author)

Rothkopf, Michael H.

2007-08-15T23:59:59.000Z

33

Vapor Degreasing  

Science Conference Proceedings (OSTI)

Table 6   Applications of vapor degreasing by vapor-spray-vapor systems...hardware Brass 2270 5000 Buffing compound; rouge Lacquer spray Racked work on continuous monorail Acoustic ceiling tile Steel 2720 6000 Light oil (stamping lubricant) Painting Monorail conveyor Gas meters Terneplate 4540 10,000 Light oil Painting Monorail conveyor Continuous strip, 0.25??4.1 mm...

34

Vapor Characterization  

Science Conference Proceedings (OSTI)

... thermodynamics (that is, vapor liquid equilibrium) as ... of solids and low volatility liquids is extraordinarily ... such situations is the gas saturation method ...

2013-12-10T23:59:59.000Z

35

Denver Watts to Water | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Denver Watts to Water Denver Watts to Water Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In this section How can we help you? Build an energy program Improve building and plant performance Earn the ENERGY STAR and other recognition Benchmark energy use ENERGY STAR in action Communicate and educate ENERGY STAR communications toolkit Bring Your Green to Work with ENERGY STAR

36

Watts Community, Oklahoma: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Watts Community, Oklahoma: Energy Resources Watts Community, Oklahoma: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 36.035006°, -94.5727598° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.035006,"lon":-94.5727598,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

37

Stacked vapor fed amtec modules  

DOE Patents (OSTI)

The present invention pertains to a stacked AMTEC module. The invention includes a tubular member which has an interior. The member is comprised of a ion conductor that substantially conducts ions relative to electrons, preferably a beta"-alumina solid electrolyte, positioned about the interior. A porous electrode for conducting electrons and allowing sodium ions to pass therethrough, and wherein electrons and sodium ions recombine to form sodium is positioned about the beta"-alumina solid electrolyte. The electrode is operated at a temperature and a pressure that allows the recombined sodium to vaporize. Additionally, an outer current collector grid for distributing electrons throughout the porous electrode is positioned about and contacts the porous electrode. Also included in the invention is transporting means for transporting liquid sodium to the beta"-alumina solid electrolyte of the tubular member. A transition piece is positioned about the interior of the member and contacts the transporting means. The transition piece divides the member into a first cell and a second cell such that each first and second cell has a beta"-alumina solid electrolyte, a first and second porous electrode and a grid. The transition piece conducts electrons from the interior of the tubular member. There is supply means for supplying sodium to the transporting means. Preferably the supply means is a shell which surrounds the tubular member and is operated at a temperature such that the vaporized sodium condenses thereon. Returning means for returning the condensed sodium from the shell to the transporting means provides a continuous supply of liquid sodium to the transporting means. Also, there are first conducting means for conducting electric current from the transition piece which extends through the shell, and second conducting means for conducting electric current to the grid of the first cell which extends through the shell.

Sievers, Robert K. (North Huntingdon, PA)

1989-01-01T23:59:59.000Z

38

New River Light & Power Co | Open Energy Information  

Open Energy Info (EERE)

New River Light & Power Co New River Light & Power Co Place North Carolina Utility Id 13482 Utility Location Yes Ownership S NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt SV TOB Lighting 150 Watt SV TOB Lighting 150 Watt Sodium Vapor Lighting 175 Watt MV TOB Lighting 175 Watt Mercury Vapor Lighting 250 Watt Metal Halide Lighting 250 Watt SV TOB Lighting 250 Watt Sodium Vapor Lighting 400 Watt MV TOB Lighting 400 Watt Mercury Vapor Lighting 400 Watt Metal Halide Lighting 400 Watt SV TOB Lighting 750 Watt SV TOB Lighting

39

Method of removing bulk sodium from metallic surfaces  

DOE Patents (OSTI)

A process of removing sodium from an article, particularly one made of stainless steel, by treating it with a mixture of water vapor and a gas which is inert to sodium is described. By selecting combinations of temperature and water vapor-to-gas ratio, the reaction temperature is controlled to prevent damage to the articles.

Maffei, H.P.; Borisch, R.R.

1975-11-11T23:59:59.000Z

40

Thermophysical Properties of Sodium Nitrate and Sodium Chloride  

Office of Scientific and Technical Information (OSTI)

Thermophysical Properties of Sodium Nitrate and Sodium Chloride Thermophysical Properties of Sodium Nitrate and Sodium Chloride Solutions and Their Effects on Fluid Flow in Unsaturated Media Tianfu Xu and Karsten Pruess Earth Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 ABSTRACT. Understanding movement of saline sodium nitrate (NaNO 3 ) waste solutions is important for assessing the contaminant migration near leaking waste storage tanks in the unsaturated zone at the Hanford site (Washington, USA). The purpose of this study is to contribute a basic understanding of effects of the thermophysical behavior of NaNO 3 solutions on fluid flow in unsaturated media. We first present mathematical expressions for the dependence of density, viscosity, solubility and vapor pressure of

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

HIGH INTENSITY DISCHARGE 400-WATT SODIUM BALLAST PHASE I FINAL REPORT  

E-Print Network (OSTI)

Output as a f n of line volt volts, and the test terminated at77H312 LRL :nG. 18 LA)YLP VOLTS Unh~$$ otherwise stiHed J aU

Felper, G.

2010-01-01T23:59:59.000Z

42

ORNL Trusted Corridors Project: Watts Bar Dam Inland Waterway Project  

Science Conference Proceedings (OSTI)

Radiation has existed everywhere in the environment since the Earth's formation - in rocks, soil, water, and plants. The mining and processing of naturally occurring radioactive materials for use in medicine, power generation, consumer products, and industry inevitably generate emissions and waste. Radiological measuring devices have been used by industry for years to measure for radiation in undesired locations or simply identify radioactive materials. Since the terrorist attacks on the United States on 9-11-01 these radiation measuring devices have proliferated in many places in our nation's commerce system. DOE, TVA, the Army Corps and ORNL collaborated to test the usefulness of these devices in our nation's waterway system on this project. The purpose of the Watts Bar Dam ORNL Trusted Corridors project was to investigate the security, safety and enforcement needs of local, state and federal government entities for state-of-the-art sensor monitoring in regards to illegal cargo including utilization of the existing infrastructure. TVA's inland waterways lock system is a recognized and accepted infrastructure by the commercial carrier industry. Safety Monitoring activities included tow boat operators, commercial barges and vessels, recreational watercraft and their cargo, identification of unsafe vessels and carriers, and, monitoring of domestic and foreign commercial vessels and cargo identification. Safety Enforcement activities included cargo safety, tracking, identification of hazardous materials, waterway safety regulations, and hazardous materials regulations. Homeland Security and Law Enforcement Applications included Radiological Dispersive Devices (RDD) identification, identification of unsafe or illicit transport of hazardous materials including chemicals and radiological materials, and screening for shipments of illicit drugs. In the Fall of 2005 the SensorNet funding for the project expired. After several unsuccessful attempts to find a Federal sponsor to continue with the project, the Watts Bar Dam Project was canceled and the Exploranium radiation monitors were removed from the doors of Watts Bar Dam in early 2006. The DHS Domestic Nuclear Detection Office decided to proceed with a Pilot building on the ORNL work performed at the TN and SC weigh stations in the highway sector of the Trusted Corridors project and eventually expanded it to other southern states under the name of Southeastern Corridor Pilot Project (SETCP). Many of the Phase I goals were achieved however real-world test data of private watercraft and barges was never obtained.

Walker, Randy M [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Hill, David E [ORNL

2011-11-01T23:59:59.000Z

43

Glassy Aging with Modified Kohlrausch-Williams-Watts Form  

E-Print Network (OSTI)

In this report we address the question whether aging in the non equilibrium glassy state is controlled by the equilibrium alpha-relaxation process which occur at temperatures above Tg. Recently Lunkenheimer et. al. [Phys. Rev. Lett. 95, 055702 (2005)] proposed a model for the glassy aging data of dielectric relaxation using a modified Kohlrausch-Williams-Watts (KWW) form. The aging time dependence of the relaxation time is defined by these authors through a functional relation involving the corresponding frequency but the stretching exponent is same as the alpha-relaxation stretching exponent. We present here an alternative functional form directly involving the relaxation time itself. The proposed model fits the data of Lunkenheimer et. al. perfectly with a stretching exponent different from the alpha-relaxation stretching exponent.

Bhaskar Sen Gupta; Shankar P. Das

2007-12-27T23:59:59.000Z

44

University of Hawai`i Watt Watcher: Energy Consumption Data Analysis  

E-Print Network (OSTI)

, 2012 Prepared for: Forest City Military Communities Hawaii Prepared By: UH Watt Watcher Team Hawaii. In its first project, the UH Watt Watcher program teamed with Forest City Military Communities-Hawaii 69% of the monthly consumption. OBJECTIVES The objective of Phase I was to inform Forest City of key

45

City of Elizabethton, Tennessee (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Elizabethton, Tennessee (Utility Company) Elizabethton, Tennessee (Utility Company) Jump to: navigation, search Name City of Elizabethton Place Tennessee Utility Id 5763 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Lighting 1000 Watt Mercury Vapor Lighting 1000 Watt Metal Halide Lighting 150 Watt High Pressure Sodium Lighting 175 Watt Mercury Vapor Lighting 250 Watt High Pressure Sodium Lighting 250 Watt Mercury Vapor Lighting 400 Watt Mercury Vapor Lighting 400 Watt Metal Halide Lighting

46

Data:400e36f6-0b25-4bb8-b4bc-6e1069c0d9f5 | Open Energy Information  

Open Energy Info (EERE)

Rate name: Schedule L-P: Private Area Lighting, 360 Watt, High Pressure Sodium Vapor Street Light Sector: Lighting Description: Rate is subject to a Purchased Power Cost...

47

Data:1e1ff35a-c0f3-461c-8a39-d529ee17b3d2 | Open Energy Information  

Open Energy Info (EERE)

Indiana (Utility Company) Effective date: End date if known: Rate name: Municipal street light service - 250 Watt Sodium Vapor Sector: Lighting Description: Source or...

48

Data:29931a10-7da0-4dbf-8551-6df2a8299026 | Open Energy Information  

Open Energy Info (EERE)

Company) Effective date: End date if known: Rate name: Sodium Vapor 200 Watt Cobra (Street Light Schedule S-1) Sector: Lighting Description: This schedule applies to electric...

49

Data:01672923-58cc-4456-b1e5-ae09b3ab3683 | Open Energy Information  

Open Energy Info (EERE)

(Utility Company) Effective date: End date if known: Rate name: Sodium Vapor 100 Watt (Street Light Schedule S-1) Sector: Lighting Description: This schedule applies to electric...

50

Data:434e0e5c-a044-4d16-b0e5-b780f31eb32e | Open Energy Information  

Open Energy Info (EERE)

(Utility Company) Effective date: End date if known: Rate name: Sodium Vapor 400 Watt (Street Light Schedule S-1) Sector: Lighting Description: This schedule applies to electric...

51

Data:513ed031-9041-4dc6-b8df-07ece9fc12c8 | Open Energy Information  

Open Energy Info (EERE)

Effective date: End date if known: Rate name: Sodium Vapor 100 Watt Cutoff Optic (Street Light Schedule S-1) Sector: Lighting Description: This schedule applies to electric...

52

Calibrated vapor generator source  

DOE Patents (OSTI)

A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet.

Davies, John P. (Idaho Falls, ID); Larson, Ronald A. (Idaho Falls, ID); Goodrich, Lorenzo D. (Shelley, ID); Hall, Harold J. (Idaho Falls, ID); Stoddard, Billy D. (Idaho Falls, ID); Davis, Sean G. (Idaho Falls, ID); Kaser, Timothy G. (Idaho Falls, ID); Conrad, Frank J. (Albuquerque, NM)

1995-01-01T23:59:59.000Z

53

Calibrated vapor generator source  

DOE Patents (OSTI)

A portable vapor generator is disclosed that can provide a controlled source of chemical vapors, such as, narcotic or explosive vapors. This source can be used to test and calibrate various types of vapor detection systems by providing a known amount of vapors to the system. The vapor generator is calibrated using a reference ion mobility spectrometer. A method of providing this vapor is described, as follows: explosive or narcotic is deposited on quartz wool, placed in a chamber that can be heated or cooled (depending on the vapor pressure of the material) to control the concentration of vapors in the reservoir. A controlled flow of air is pulsed over the quartz wool releasing a preset quantity of vapors at the outlet. 10 figs.

Davies, J.P.; Larson, R.A.; Goodrich, L.D.; Hall, H.J.; Stoddard, B.D.; Davis, S.G.; Kaser, T.G.; Conrad, F.J.

1995-09-26T23:59:59.000Z

54

Study of the interactions of molten sodium nitrate-potassium nitrate 50 mol % mixture with water vapor and carbon dioxide in air. Final report, June 2, 1980-June 30, 1981  

DOE Green Energy (OSTI)

The interactions of aerial components such as water, carbon dioxide, and oxygen with the binary 50 mol % mixture of sodium nitrate and potassium nitrate have been studied in the temperature range 300 to 600/sup 0/C using electrochemical methods. In addition, the behavior of nitrite ions in this melt was investigated electrochemically. By judicious choice of techniques, in situ electroanalysis was possible and the necessary relevant data to accomplish this is presented, as well as insight into the corresponding electrochemical mechanisms associated with the electroactive species. The influence of each atmospheric component was examined separately. At temperatures above 300/sup 0/C, nitrite ions are found to accumulate due to thermal decomposition of the nitrate. Water is highly soluble in the salt mixture, but no hydrolytic reactions were observed. Two methods of in situ analysis for water are described. Pure carbon dioxide is found to attack the melt at all temperatures above 250/sup 0/C producing carbonate. (LEW)

White, S.H.; Twardoch, U.M.

1981-09-01T23:59:59.000Z

55

Mercury Vapor Pressure Correlation  

Science Conference Proceedings (OSTI)

An apparent difference between the historical mercury vapor concentration equations used by the mercury atmospheric measurement community ...

2012-10-09T23:59:59.000Z

56

Watch the Watts: Tips for Buying a New Television | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Watch the Watts: Tips for Buying a New Television Watch the Watts: Tips for Buying a New Television Watch the Watts: Tips for Buying a New Television March 8, 2011 - 6:30am Addthis Jeannie Saur Senior Communicator, National Renewable Energy Laboratory Buying a new television in a complex and feature-rich market can be a daunting experience. Sure there are lots of great choices with stunning picture quality and amazing features. And with so much competition, TV prices have fallen dramatically from even a year ago. But when my 1990-era television finally died, I was overwhelmed with choices for a flat screen TV. There are plasmas, liquid crystal displays (LCDs), and light-emitting diodes (LEDs). TVs can be Internet enabled so they can stream programming. And now there are a number of choices for 3D viewing. With so many things to consider, I decided the most important

57

The Kill-a-Watt Competition at University of Central Florida | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Kill-a-Watt Competition at University of Central Florida The Kill-a-Watt Competition at University of Central Florida The Kill-a-Watt Competition at University of Central Florida Addthis Description At the University of Central Florida, students have taken it upon themselves to create a culture of energy efficiency. Each year, different dorm buildings compete to see who can save the most. In 2009, the school saw a total savings of $27,000. As of March 2010, they've saved over $24,000 this year alone. Speakers Chris Castro, Alexandra Kennedy, Margaret Lo, David Norvell, Keith Coelho, John Hitt PhD Duration 5:40 Topic Energy Efficiency Commercial Heating & Cooling Consumption Credit Energy Department Video CHRIS CASTRO: Last summer, I was an intern at the Department of Energy Office of Energy Efficiency and Renewable Energy and I got a chance to

58

Solar-induced chemical vapor deposition of diamond-type carbon films  

DOE Patents (OSTI)

An improved chemical vapor deposition method for depositing transparent continuous coatings of sp[sup 3]-bonded diamond-type carbon films, comprises: (a) providing a volatile hydrocarbon gas/H[sub 2] reactant mixture in a cold wall vacuum/chemical vapor deposition chamber containing a suitable substrate for said films, at pressure of about 1 to 50 Torr; and (b) directing a concentrated solar flux of from about 40 to about 60 watts/cm[sup 2] through said reactant mixture to produce substrate temperatures of about 750 C to about 950 C to activate deposition of the film on said substrate. 11 figs.

Pitts, J.R.; Tracy, C.E.; King, D.E.; Stanley, J.T.

1994-09-13T23:59:59.000Z

59

Direct radiometric observations of the water vapor greenhouse effect over the equatorial Pacific ocean  

SciTech Connect

Airborne radiometric measurements were used to determine tropospheric profiles of the clear sky greenhouse effect. At sea surface temperatures (SSTs) larger than 300 kelvin, the clear sky water vapor greenhouse effect was found to increase with SST at a rate of 13 to 15 watts per square meter per kelvin. Satellite measurements of infrared radiances and SSTs indicate that almost 52 percent of the tropical oceans between 20{degrees}N and 20{degrees}S are affected during all seasons. Current general circulation models suggest that the increase in the clear sky water vapor greenhouse effect with SST may have climatic effects on a planetary scale. 23 refs., 5 figs., 1 tab.

Valero, F.P.J.; Collins, W.D.; Bucholtz, A. [Univ. of California, La Jolla, CA (United States)] [and others

1997-03-21T23:59:59.000Z

60

Solar-induced chemical vapor deposition of diamond-type carbon films  

DOE Patents (OSTI)

An improved chemical vapor deposition method for depositing transparent continuous coatings of sp.sup.3 -bonded diamond-type carbon films, comprising: a) providing a volatile hydrocarbon gas/H.sub.2 reactant mixture in a cold wall vacuum/chemical vapor deposition chamber containing a suitable substrate for said films, at pressure of about 1 to 50 Torr; and b) directing a concentrated solar flux of from about 40 to about 60 watts/cm.sup.2 through said reactant mixture to produce substrate temperatures of about 750.degree. C. to about 950.degree. C. to activate deposition of the film on said substrate.

Pitts, J. Roland (Lakewood, CO); Tracy, C. Edwin (Golden, CO); King, David E. (Lakewood, CO); Stanley, James T. (Beaverton, OR)

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

City of Frankfort, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Frankfort Frankfort Place Indiana Utility Id 6707 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png A Residential Residential B Commercial Commercial C General Power Economic Development Rate OL Outdoor Lighting 100 watt Sodium Vapor Lighting OL Outdoor Lighting 150 watt Sodium Vapor Lighting OL Outdoor Lighting 175 watt Mercury Vapor Lighting OL Outdoor Lighting 250 watt Mercury Vapor Lighting OL Outdoor Lighting 250 watt Sodium Vapor Lighting OL Outdoor Lighting 400 watt Mercury Vapor Lighting

62

A 5-WATT, 37-GHz MONOLITHIC GRID AMPLIFIER Blythe Deckman1  

E-Print Network (OSTI)

of the fabricated active grid. Thermal Management Previous grid amplifiers lacked a heat spreader, so Figure 1A 5-WATT, 37-GHz MONOLITHIC GRID AMPLIFIER Blythe Deckman1 , Donald S. Deakin, Jr.2 , Emilio Sovero has been demonstrated. The area of the grid am- plifier is 1 cm2, and there are 512 transistors

Rutledge, David B.

63

DIESEL AEROSOL SAMPLING IN THE David Kittelson, Jason Johnson, and Winthrop Watts  

E-Print Network (OSTI)

chemical composition of diesel particulate matter collected in laboratory and in wind tunnel #12;In OrderDIESEL AEROSOL SAMPLING IN THE ATMOSPHERE David Kittelson, Jason Johnson, and Winthrop Watts Center for Diesel Research University of Minnesota 10th CRC ON-ROAD VEHICLE EMISSIONS WORKSHOP San Diego, California

Minnesota, University of

64

University of Hawai`i Watt Watcher: Energy Consumption Data Analysis  

E-Print Network (OSTI)

Consumption Data Analysis Phase I Interim Report March 30, 2011 Prepared for: Forest City Military RECOMMENDATIONS TO FOREST CITY 12 ITEMS TO ADD TO FOREST CITY TURNOVER PUNCH LIST 17 APPENDIXUniversity of Hawai`i Watt Watcher: Energy Consumption Data Analysis Phase I Interim Report

65

400-Watt Electronic High-Bay Fixture for Metal-Halide High-Intensity Discharge Lighting  

Science Conference Proceedings (OSTI)

The product under assessment is an advanced lighting technology8212a 400-watt, metal-halide, electronic high-intensity discharge (HID) ballast technology designed to be operated as a stand-alone ballast or integrated as a fixture where the ballast becomes part of the fixture mechanical support system.

2008-06-12T23:59:59.000Z

66

Using Complete Machine Simulation for Software Power Estimation: The SoftWatt Approach  

E-Print Network (OSTI)

Using Complete Machine Simulation for Software Power Estimation: The SoftWatt Approach Sudhanva,anand,mji,vijay,kandemirg@cse.psu.edu Tao Li Lizy Kurian John Dept. of Electrical and Computer Engineering University of Texas at Austin of the SimOS infrastructure, uses validated analytical energy models to identify the power hotspots

John, Lizy Kurian

67

WattApp: an application aware power meter for shared data centers  

Science Conference Proceedings (OSTI)

The increasing heterogeneity between applications in emerging virtualized data centers like clouds introduce significant challenges in estimating the power drawn by the data center. In this work, we presentWattApp: an application-aware power meter for ... Keywords: power modeling

Ricardo Koller; Akshat Verma; Anindya Neogi

2010-06-01T23:59:59.000Z

68

Statistical analysis of wind energy in Chile David Watts a,b,*, Danilo Jara a  

E-Print Network (OSTI)

Data Bank Statistical analysis of wind energy in Chile David Watts a,b,*, Danilo Jara December 2010 Keywords: Wind Wind speed Energy Capacity factor Electricity Chile a b s t r a c t Bearing role in any future national energy generation matrix. With a view to understanding the local wind

Catholic University of Chile (Universidad Católica de Chile)

69

Vapor spill monitoring method  

DOE Patents (OSTI)

Method for continuous sampling of liquified natural gas effluent from a spill pipe, vaporizing the cold liquified natural gas, and feeding the vaporized gas into an infrared detector to measure the gas composition. The apparatus utilizes a probe having an inner channel for receiving samples of liquified natural gas and a surrounding water jacket through which warm water is flowed to flash vaporize the liquified natural gas.

Bianchini, Gregory M. (Livermore, CA); McRae, Thomas G. (Livermore, CA)

1985-01-01T23:59:59.000Z

70

Dalton Utilities | Open Energy Information  

Open Energy Info (EERE)

Dalton Utilities Dalton Utilities Jump to: navigation, search Name Dalton Utilities Place Georgia Utility Id 4744 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 - Watt Sodium Vapor Lighting 1000 - Watt Metal Halide Directional Type Lighting 150 Watt Mercury Vapor Underground Service Lighting 150 Watt Sodium Vapor Underground Service Lighting 175 - Watt Mercury Vapor Lighting 175 - Watt Sodium Vapor Lighting

71

City of Emerson, Nebraska (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Emerson, Nebraska (Utility Company) Emerson, Nebraska (Utility Company) Jump to: navigation, search Name City of Emerson Place Nebraska Utility Id 5850 Utility Location Yes Ownership M NERC Location MRO Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 watt High Pressure Sodium Lighting 150 watt High Pressure Sodium Lighting 175 watt Mercury Vapor Lighting 250 watt High Pressure Sodium Lighting 250 watt High Pressure Sodium Flood Lighting 250 watt Mercury Vapor Lighting 400 watt High Pressure Sodium Flood Lighting

72

The distribution of the electric current in a watt-balance coil  

E-Print Network (OSTI)

In the watt balance experiment, separate measurements of the Lorentz and electromotive forces in a coil in a radial magnetic field enable a virtual comparison between mechanical and electric powers to be carried out, which lead to an accurate measurement of the Planck constant. This paper investigates the effect of a spatially inhomogeneous distribution of the electric current in the coil due to the higher or lower resistance of the outer or inner paths.

Sasso, Carlo Paolo; Mana, Giovanni

2013-01-01T23:59:59.000Z

73

William Watts  

NLE Websites -- All DOE Office Websites (Extended Search)

for David Lorenzetti, and Tracy Thatcher. This Speaker's Seminars GE Nucleus for Residential Energy Use Education, Home Energy ManagementControl, Residential Energy Integration...

74

Acoustic emission monitoring of hot functional testing: Watts Bar Unit 1 Nuclear Reactor  

Science Conference Proceedings (OSTI)

Acoustic emission (AE) monitoring of selected pressure boundary areas at TVA's Watts Bar, Unit 1 Nuclear Power Plant during hot functional preservice testing is described in this report. The report deals with background, methodology, and results. The work discussed here is a major milestone in a program supported by NRC to develop and demonstrate application of AE monitoring for continuous surveillance of reactor pressure boundaries to detect and evaluate growing flaws. The subject work demonstrated that anticipated problem areas can be overcome. Work is continuing toward AE monitoring during reactor operation.

Hutton, P.H.; Dawson, J.F.; Friesel, M.A.; Harris, J.C.; Pappas, R.A.

1984-06-01T23:59:59.000Z

75

Lumen Maintenance Testing of the Philips 60-Watt Replacement Lamp L Prize Entry  

Science Conference Proceedings (OSTI)

This paper describes testing conducted to evaluate the Philips' L Prize award winning 60-watt LED replacement product's ability to meet the lifetime/lumen maintenance requirement of the competition, which was: "having 70 percent of the lumen value under subparagraph (A) [producing a luminous flux greater than 900 lumens] exceeding 25,000 hours under typical conditions expected in residential use." A custom test apparatus was designed and constructed for this testing and a statistical approach was developed for use in evaluating the test results. This will be the only publicly available, third-party data set of long-term LED product operation.

Gordon, Kelly L.; Hafen, Ryan P.; Hathaway, John E.; McCullough, Jeffrey J.

2012-09-01T23:59:59.000Z

76

Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamp systems are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the systems efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.; Morse, O.

1988-02-01T23:59:59.000Z

77

Remedial investigation/feasibility study report for Lower Watts Bar Reservoir Operable Unit  

SciTech Connect

This document is the combined Remedial Investigation and Feasibility Study Report for the lower Watts Bar Reservoir (LWBR) Operable Unit (OU). The LWBR is located in Roane, Rhea, and Meigs counties, Tennessee, and consists of Watts Bar Reservoir downstream of the Clinch river. This area has received hazardous substances released over a period of 50 years from the US Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). As required by this law, the ORR and all off-site areas that have received contaminants, including LWBR, must be investigated to determine the risk to human health and the environment resulting from these releases, the need for any remedial action to reduce these risks, and the remedial actions that are most feasible for implementation in this OU. Contaminants from the ORR are primarily transported to the LWBR via the Clinch River. There is little data regarding the quantities of most contaminants potentially released from the ORR to the Clinch River, particularly for the early years of ORR operations. Estimates of the quantities released during this period are available for most radionuclides and some inorganic contaminants, indicating that releases 30 to 50 years ago were much higher than today. Since the early 1970s, the release of potential contaminants has been monitored for compliance with environmental law and reported in the annual environmental monitoring reports for the ORR.

NONE

1995-03-01T23:59:59.000Z

78

City of Lebanon, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Indiana Indiana Utility Id 9613 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png CS - Electric Commercial Polyphase Commercial CS - Electric Commercial Single Phase Commercial MS - Electric Municipal OL - Outdoor Lighting 100 watt sodium vapor Lighting OL - Outdoor Lighting 150 watt sodium vapor Lighting OL - Outdoor Lighting 175 watt mercury vapor Lighting OL - Outdoor Lighting 200 watt sodium vapor Lighting OL - Outdoor Lighting 250 watt mercury vapor Lighting

79

Electrolyte vapor condenser  

DOE Patents (OSTI)

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well. 3 figs.

Sederquist, R.A.; Szydlowski, D.F.; Sawyer, R.D.

1983-02-08T23:59:59.000Z

80

Electrolyte vapor condenser  

DOE Patents (OSTI)

A system is disclosed for removing electrolyte from a fuel cell gas stream. The gas stream containing electrolyte vapor is supercooled utilizing conventional heat exchangers and the thus supercooled gas stream is passed over high surface area passive condensers. The condensed electrolyte is then drained from the condenser and the remainder of the gas stream passed on. The system is particularly useful for electrolytes such as phosphoric acid and molten carbonate, but can be used for other electrolyte cells and simple vapor separation as well.

Sederquist, Richard A. (Newington, CT); Szydlowski, Donald F. (East Hartford, CT); Sawyer, Richard D. (Canton, CT)

1983-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Vapor concentration monitor  

DOE Patents (OSTI)

An apparatus for monitoring the concentration of a vapor, such as heavy water, having at least one narrow bandwidth in its absorption spectrum, in a sample gas such as air. The air is drawn into a chamber in which the vapor content is measured by means of its radiation absorption spectrum. High sensitivity is obtained by modulating the wavelength at a relatively high frequency without changing its optical path, while high stability against zero drift is obtained by the low frequency interchange of the sample gas to be monitored and of a reference sample. The variable HDO background due to natural humidity is automatically corrected.

Bayly, John G. (Deep River, CA); Booth, Ronald J. (Deep River, CA)

1977-01-01T23:59:59.000Z

82

Definition: Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor Jump to: navigation, search Dictionary.png Mercury Vapor Mercury is discharged as a highly volatile vapor during hydrothermal activity and high concentrations in...

83

Hickman-Fulton Counties RECC | Open Energy Information  

Open Energy Info (EERE)

Hickman-Fulton Counties RECC Hickman-Fulton Counties RECC Jump to: navigation, search Name Hickman-Fulton Counties RECC Place Kentucky Utility Id 40305 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Lighting 100 Watt Metal Halide Light Lighting 175 Watt Mercury Vapor Light Lighting 175 Watt Metal Halide Light Lighting 200 Watt High Pressure Sodium Lighting 400 Watt High Pressure Sodium Lighting 400 Watt Mercury Vapor Light Lighting GSA Part 1 Commercial GSA Part 2 Industrial

84

Organic vapor jet printing system  

DOE Patents (OSTI)

An organic vapor jet printing system includes a pump for increasing the pressure of an organic flux.

Forrest, Stephen R

2012-10-23T23:59:59.000Z

85

Narrow linewidth picosecond pulsed laser with mega-watt peak power at UV wavelength  

Science Conference Proceedings (OSTI)

We demonstrate a master oscillator power amplifier (MOPA) burst mode laser system to generate 66 ps/402.5 MHz pulses with mega-watt peak power at 355 nm. The seed laser is based on a direct electro-optic modulation of a fiber laser output. A very high extinction ratio (45 dB) has been achieved by using an adaptive bias control. The multi-stage Nd:YAG amplifier system allows a uniformly temporal shaping of macropulses with tunable pulse duration. The light output form the amplifier is converted to 355 nm and over 1 MW UV peak power is obtained when the laser is operating in a 5- s/10-Hz macropulse mode. The laser output has a transform limited spectrum bandwidth with a very narrow linewidth of individual laser mode. The immediate application of the laser system is the laser assisted hydrogen ion beam stripping for the Spallation Neutron Source (SNS).

Liu, Yun [ORNL; Huang, Chunning [ORNL; Deibele, Craig Edmond [ORNL

2013-01-01T23:59:59.000Z

86

Mercury Vapor | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor Mercury Vapor Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Mercury Vapor Details Activities (23) Areas (23) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Fluid Lab Analysis Parent Exploration Technique: Fluid Lab Analysis Information Provided by Technique Lithology: Stratigraphic/Structural: Anomalously high concentrations can indicate high permeability or conduit for fluid flow Hydrological: Field wide soil sampling can generate a geometrical approximation of fluid circulation Thermal: High concentration in soils can be indicative of active hydrothermal activity Dictionary.png Mercury Vapor: Mercury is discharged as a highly volatile vapor during hydrothermal

87

Stratified vapor generator  

DOE Patents (OSTI)

A stratified vapor generator (110) comprises a first heating section (H.sub.1) and a second heating section (H.sub.2). The first and second heating sections (H.sub.1, H.sub.2) are arranged so that the inlet of the second heating section (H.sub.2) is operatively associated with the outlet of the first heating section (H.sub.1). A moisture separator (126) having a vapor outlet (164) and a liquid outlet (144) is operatively associated with the outlet (124) of the second heating section (H.sub.2). A cooling section (C.sub.1) is operatively associated with the liquid outlet (144) of the moisture separator (126) and includes an outlet that is operatively associated with the inlet of the second heating section (H.sub.2).

Bharathan, Desikan (Lakewood, CO); Hassani, Vahab (Golden, CO)

2008-05-20T23:59:59.000Z

88

Fuel vapor canister  

SciTech Connect

This paper discusses an improved fuel vapor storage canister for use in a vehicle emission system of the type utilizing an enclosure with an interior communicated with a source of fuel vapor. The improved canister comprises: the enclosure having a mixture including particles of activated charcoal and many pieces of foam rubber, the pieces of foam rubber in the mixture being randomly and substantially evenly dispersed whereby substantially all the charcoal particles are spaced relatively closely to at least one foam rubber piece; the mixture being packed into the enclosure under pressure so that the pieces of foam rubber are compressed enough to tightly secure the charcoal particles one against another to prevent a griding action therebetween.

Moskaitis, R.J.; Ciuffetelli, L.A.

1991-03-26T23:59:59.000Z

89

METHOD FOR REMOVING SODIUM OXIDE FROM LIQUID SODIUM  

DOE Patents (OSTI)

A method is described for removing sodium oxide from a fluent stream of liquid sodium by coldtrapping the sodium oxide. Apparatus utilizing this method is disclosed in United States Patent No. 2,745,552. Sodium will remain in a molten state at temperatures below that at which sodium oxide will crystallize out and form solid deposits, therefore, the contaminated stream of sodium is cooled to a temperature at which the solubility of sodium oxide in sodium is substantially decreased. Thereafter the stream of sodium is passed through a bed of stainless steel wool maintained at a temperature below that of the stream. The stream is kept in contact with the wool until the sodium oxide is removed by crystal growth on the wool, then the stream is reheated and returned to the system. This method is useful in purifying reactor coolants where the sodium oxide would otherwise deposit out on the walls and eventually plug the coolant tubes.

Bruggeman, W.H.; Voorhees, B.G.

1957-12-01T23:59:59.000Z

90

VAPOR PRESSURES AND HEATS OF VAPORIZATION OF PRIMARY COAL TARS  

DOE Green Energy (OSTI)

This project had as its main focus the determination of vapor pressures of coal pyrolysis tars. It involved performing measurements of these vapor pressures and from them, developing vapor pressure correlations suitable for use in advanced pyrolysis models (those models which explicitly account for mass transport limitations). This report is divided into five main chapters. Each chapter is a relatively stand-alone section. Chapter A reviews the general nature of coal tars and gives a summary of existing vapor pressure correlations for coal tars and model compounds. Chapter B summarizes the main experimental approaches for coal tar preparation and characterization which have been used throughout the project. Chapter C is concerned with the selection of the model compounds for coal pyrolysis tars and reviews the data available to us on the vapor pressures of high boiling point aromatic compounds. This chapter also deals with the question of identifying factors that govern the vapor pressures of coal tar model materials and their mixtures. Chapter D covers the vapor pressures and heats of vaporization of primary cellulose tars. Chapter E discusses the results of the main focus of this study. In summary, this work provides improved understanding of the volatility of coal and cellulose pyrolysis tars. It has resulted in new experimentally verified vapor pressure correlations for use in pyrolysis models. Further research on this topic should aim at developing general vapor pressure correlations for all coal tars, based on their molecular weight together with certain specific chemical characteristics i.e. hydroxyl group content.

Eric M. Suuberg; Vahur Oja

1997-07-01T23:59:59.000Z

91

Human Sodium Risks  

NLE Websites -- All DOE Office Websites (Extended Search)

comes from restaurants and it can be hard for a person to tell how much sodium is in restaurant foods. Brands of foods matter: Different brands of the same foods may have...

92

Solar test of an integrated sodium reflux heat pipe receiver/reactor for thermochemical energy transport  

DOE Green Energy (OSTI)

A chemical reactor for carbon dioxide reforming of methane was integrated into a sodium reflux heat pipe receiver and tested in the solar furnace of the Weizmann Institute of Science, Rehovot, Israel. The receiver/reactor was a heat pipe with seven tubes inside an evacuated metal box containing sodium. The catalyst, 0.5 wt% Rh on alumina, filled two of the tubes with the front surface of the box serving as the solar absorber. In operation, concentrated sunlight heated the front plate and vaporized sodium from a wire mesh wick attached to other side. Sodium vapor condensed on the reactor tubes, releasing latent heat and returning to the wick by gravity. The receiver system performed satisfactorily in many tests under varying flow conditions. The maximum power absorbed was 7.5 kW at temperatures above 800C. The feasibility of operating a heat pipe receiver/reactor under solar conditions was proven, and the advantages of reflux devices confirmed.

Diver, R.B.; Fish, J.D. (Sandia National Labs., Albuquerque, NM (United States)); Levitan, R.; Levy, M.; Meirovitch, E.; Rosin, H. (Weizmann Inst. of Science, Rehovot (Israel)); Paripatyadar, S.A.; Richardson, J.T. (Univ. of Houston, TX (United States))

1992-01-01T23:59:59.000Z

93

Vapor spill pipe monitor  

DOE Patents (OSTI)

The invention is a method and apparatus for continually monitoring the composition of liquefied natural gas flowing from a spill pipe during a spill test by continually removing a sample of the LNG by means of a probe, gasifying the LNG in the probe, and sending the vaporized LNG to a remote ir gas detector for analysis. The probe comprises three spaced concentric tubes surrounded by a water jacket which communicates with a flow channel defined between the inner and middle, and middle and outer tubes. The inner tube is connected to a pump for providing suction, and the probe is positioned in the LNG flow below the spill pipe with the tip oriented partly downward so that LNG is continuously drawn into the inner tube through a small orifice. The probe is made of a high thermal conductivity metal. Hot water is flowed through the water jacket and through the flow channel between the three tubes to provide the necessary heat transfer to flash vaporize the LNG passing through the inner channel of the probe. The gasified LNG is transported through a connected hose or tubing extending from the probe to a remote ir sensor which measures the gas composition.

Bianchini, G.M.; McRae, T.G.

1983-06-23T23:59:59.000Z

94

Williamstown Utility Comm | Open Energy Information  

Open Energy Info (EERE)

Williamstown Utility Comm Williamstown Utility Comm Jump to: navigation, search Name Williamstown Utility Comm Place Kentucky Utility Id 20731 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Area Light Lighting 150 Watt High Pressure Sodium Floodlight Lighting 175 Watt Mercury Vapor Area Light Lighting 250 Watt High Pressure Sodium Area Light Lighting 250 Watt High Pressure Sodium Floodlight Lighting 400 Watt High Pressure Sodium Area Light Lighting

95

Data:D9bee037-417d-431f-b5af-37528d787421 | Open Energy Information  

Open Energy Info (EERE)

if known: Rate name: Schedule L-S: Street Lighting, 150 Watt, High Pressure Sodium Vapor Street Light Sector: Lighting Description: Rate is subject to a Purchased Power Cost...

96

Data:F1d722f0-7529-47e4-9f14-c3e576dbdc58 | Open Energy Information  

Open Energy Info (EERE)

name: Schedule L-S: Street Lighting, 400 Watt (50,000 Lumen), High Pressure Sodium Vapor Street Light Sector: Lighting Description: Rate is subject to a Purchased Power Cost...

97

Data:046dd8fe-854d-43d5-8ab3-4870ccd60173 | Open Energy Information  

Open Energy Info (EERE)

Schedule L-P: Private Area Lighting, 400 Watt (50,000 Lumen), High Pressure Sodium Vapor Street Light Sector: Lighting Description: Rate is subject to a Purchased Power Cost...

98

Terrebonne Parish Consol Gov't | Open Energy Information  

Open Energy Info (EERE)

Terrebonne Parish Consol Gov't Terrebonne Parish Consol Gov't Jump to: navigation, search Name Terrebonne Parish Consol Gov't Place Louisiana Utility Id 8884 Utility Location Yes Ownership M NERC Location SPP NERC SPP Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Vapor Light Lighting 250 Watt High Pressure Sodium Vapor Light Cobra Head Lighting 400 Watt High Pressure Sodium Vapor Flood Light Lighting 400 Watt High Pressure Sodium Vapor Light Cobra Head Lighting

99

Study of cesium volatility from sodium carbonate based melts  

SciTech Connect

Purpose of this study was to obtain thermodynamic data on cesium volatility from sodium carbonate-based molten salts for application to the Rockwell-ETEC molten salt oxidation process. At 1073 to 1373 K, volatility tests were conducted on a horizontal and a vertical transpiration apparatus using a carrier gas composed of CO{sub 2}(g) and H{sub 2}O(g) which was passed over or bubbled through a sodium carbonate bath containing cesium carbonate and various additives. The major vapor species was identified to be CsOH(g) except when greater than 3% chloride is present in the melt, then the major vapor species is CsCl(g). The decrease in volatility of cesium as a function of cesium concentration in Cs{sub 2}CO{sub 3{minus}}Na{sub 2}CO{sub 3} mixtures follows Raoult`s law very closely. Thus, this system exhibits close to ideal solution behavior. Addition of 22.5 wt % sodium sulfate decreases the cesium volatility by just under a factor of 2, and the addition of 10.0 wt % sodium chloride increases the cesium volatility about an order of magnitude. The addition of 2.0 wt % ash, molecular sieve, or silica show little or no effect. However, the data indicate that higher concentrations of ash will decrease the cesium volatility. For the addition of 22.5 wt % sodium sulfate the activity coefficient, {gamma}(Cs{sub 2}CO{sub 3}){sup {1/2}}, is calculated to be 0.720 {plus_minus} 0.068, and for the addition of 10.0 wt % sodium chloride, the activity coefficient, {gamma}(CsCl), is calculated to be 8.118 {plus_minus} 2.317. Assuming that Henry`s law applies, these activity coefficients are used to extrapolate the effect on cesium retention in the molten salt oxidizer of sulfate and chloride at lower cesium concentrations.

Ebbinghaus, B.B.; Krikorian, O.H.; Adamson, M.G.; Fleming, D.L.

1993-12-01T23:59:59.000Z

100

Sodium sulfur battery seal  

DOE Patents (OSTI)

This disclosure is directed to an improvement in a sodium sulfur battery construction in which a seal between various battery compartments is made by a structure in which a soft metal seal member is held in a sealing position by holding structure. A pressure applying structure is used to apply pressure on the soft metal seal member when it is being held in sealing relationship to a surface of a container member of the sodium sulfur battery by the holding structure. The improvement comprises including a thin, well-adhered, soft metal layer on the surface of the container member of the sodium sulfur battery to which the soft metal seal member is to be bonded.

Mikkor, Mati (Ann Arbor, MI)

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Sodium sulfur battery seal  

SciTech Connect

This invention is directed to a seal for a sodium sulfur battery in which a flexible diaphragm sealing elements respectively engage opposite sides of a ceramic component of the battery which separates an anode compartment from a cathode compartment of the battery.

Topouzian, Armenag (Birmingham, MI)

1980-01-01T23:59:59.000Z

102

VAPOR SHIELD FOR INDUCTION FURNACE  

DOE Patents (OSTI)

This patent relates to a water-cooled vapor shield for an inductlon furnace that will condense metallic vapors arising from the crucible and thus prevent their condensation on or near the induction coils, thereby eliminating possible corrosion or shorting out of the coils. This is accomplished by placing, about the top, of the crucible a disk, apron, and cooling jacket that separates the area of the coils from the interior of the cruclbIe and provides a cooled surface upon whlch the vapors may condense.

Reese, S.L.; Samoriga, S.A.

1958-03-11T23:59:59.000Z

103

SURVEY OF SODIUM PUMP TECHNOLOGY  

SciTech Connect

A review is presented of the current status of sodium pump development as related to nuclear power applications. A description is given of the design features and performance characteristics of the more important types of sodium and sodium-- potassium alloy (NaK) pumps. Some requirements for sodium pumps for future large liquid metal reactor systems are presented with some preliminary consideration of the potential of various pump types to meet these requirements. (auth)

Nixon, D.R.

1963-06-01T23:59:59.000Z

104

Vapor adsorption process  

SciTech Connect

The removal of undesirable acid components from sour natural gas is often accomplished by a vapor adsorption process wherein a bed of solid adsorbent material is contacted with an inlet gas stream so that desired components contained in the gas stream are adsorbed on the bed, then regenerated by contact with a heated regeneration gas stream. Adsorbed components are desorbed from the bed and the bed is cooled preparatory to again being contacted with the inlet gas stream. By this process, the bed is contacted, during the regeneration cycle, with a selected adsorbable material. This material has the property of being displaced from the bed by the desired components and has a heat of desorption equal to or greater than the heat of adsorption of the desired components. When the bed is contacted with the inlet gas stream, the selected adsorbable material is displaced by the desired components resulting in the temperature of the bed remaining relatively constant, thereby allowing the utilization of the maximum bed adsorption capacity. (4 claims)

Snyder, C.F.; Casad, B.M.

1973-04-24T23:59:59.000Z

105

Atmospheric Water Vapor over China  

Science Conference Proceedings (OSTI)

Chinese radiosonde data from 1970 to 1990 are relatively homogeneous in time and are used to examine the climatology, trends, and variability of Chinas atmospheric water vapor content. The climatological distribution of precipitable water (PW) ...

Panmao Zhai; Robert E. Eskridge

1997-10-01T23:59:59.000Z

106

Sodium tetraphenylborate solubility and dissolution rates  

DOE Green Energy (OSTI)

The rate of solid sodium tetraphenylborate (NaTPB) dissolution in In-Tank Precipitation salt solutions has been experimentally determined. The data indicates that the dissolution rate of solid NaTPB is a minor contributor the lag time experienced in the 1983 Salt Decontamination Demonstration Test and should not be considered as the rate determining step. Current analytical models for predicting the time to reach the composite lower flammability limit assume that the lag time is not more than 6 hours, and the data supports this assumption (i.e., dissolution by itself requires much less than 6 hours). The data suggests that another step--such as mass transport, the reaction of a benzene precursor or the mixing behavior--is the rate determining factor for benzene release to the vapor space in Tank 48H. In addition, preliminary results from this program show that the degree of agitation employed is not a significant parameter in determining the rate of NaTPB dissolution. As a result of this study, an improved equation for predicting equilibrium tetraphenylborate solubility with respect to temperature and sodium ion concentration has been determined.

Barnes, M.J.; Peterson, R.A.; Swingle, R.F.; Reeves, C.T.

1995-12-31T23:59:59.000Z

107

Vapor deposition of hardened niobium  

DOE Patents (OSTI)

A method of coating ceramic nuclear fuel particles containing a major amount of an actinide ceramic in which the particles are placed in a fluidized bed maintained at ca. 800.degree. to ca. 900.degree. C., and niobium pentachloride vapor and carbon tetrachloride vapor are led into the bed, whereby niobium metal is deposited on the particles and carbon is deposited interstitially within the niobium. Coating apparatus used in the method is also disclosed.

Blocher, Jr., John M. (Columbus, OH); Veigel, Neil D. (Columbus, OH); Landrigan, Richard B. (Columbus, OH)

1983-04-19T23:59:59.000Z

108

Chemical vapor deposition sciences  

SciTech Connect

Chemical vapor deposition (CVD) is a widely used method for depositing thin films of a variety of materials. Applications of CVD range from the fabrication of microelectronic devices to the deposition of protective coatings. New CVD processes are increasingly complex, with stringent requirements that make it more difficult to commercialize them in a timely fashion. However, a clear understanding of the fundamental science underlying a CVD process, as expressed through computer models, can substantially shorten the time required for reactor and process development. Research scientists at Sandia use a wide range of experimental and theoretical techniques for investigating the science of CVD. Experimental tools include optical probes for gas-phase and surface processes, a range of surface analytic techniques, molecular beam methods for gas/surface kinetics, flow visualization techniques and state-of-the-art crystal growth reactors. The theoretical strategy uses a structured approach to describe the coupled gas-phase and gas-surface chemistry, fluid dynamics, heat and mass transfer of a CVD process. The software used to describe chemical reaction mechanisms is easily adapted to codes that model a variety of reactor geometries. Carefully chosen experiments provide critical information on the chemical species, gas temperatures and flows that are necessary for model development and validation. This brochure provides basic information on Sandia`s capabilities in the physical and chemical sciences of CVD and related materials processing technologies. It contains a brief description of the major scientific and technical capabilities of the CVD staff and facilities, and a brief discussion of the approach that the staff uses to advance the scientific understanding of CVD processes.

1992-12-31T23:59:59.000Z

109

Results of Performance Tests Performed on the John Watts WW Casing Connection on 7" Pipe  

SciTech Connect

Stress Engineering Services (SES) was contracted by Mr. John Watts to test his ''WW'' threaded connection developed for oilfield oil and gas service. This work was a continuation of testing performed by SES as reported in August of 1999. The connection design tested was identified as ''WW''. The samples were all integral (no coupled connections) and contained a wedge thread form with 90{sup o} flank angles relative to the pipe centerline. The wedge thread form is a variable width thread that primarily engages on the flanks. This thread form provides very high torque capacity and good stabbing ability and makeup. The test procedure selected for one of the samples was the newly written ISO 13679 procedure for full scale testing of casing and tubing connections, which is currently going through the ISO acceptance process. The ISO procedure requires a variety of tests that includes makeup/breakout testing, internal gas sealability/external water sealability testing with axial tension, axial compression, bending, internal gas thermal cycle tests and limit load (failure) tests. This test procedure was performed with one sample. Four samples were tested to failure. Table 1 contains a summary of the tasks performed by SES. The project started with the delivery of test samples by Mr. Watts. Pipe from the previous round of tests was used for the new samples. Figure 1 shows the structural and sealing results relative to the pipe body. Sample 1 was used to determine the torque capacity of the connection. Torque was applied to the capacity of SES's equipment which was 28,424 ft-lbs. From this, an initial recommended torque range of 7,200 to 8,800 ft-lbs. was selected. The sample was disassembled and while there was no galling observed in the threads, the end of the pin had collapsed inward. Sample 2 received three makeups. Breakouts 1 and 2 also had collapsing of the pin end, with no thread galling. From these make/breaks, it was decided to reduce the amount of lubricant applied to the connection by applying it to the box or pin only and reducing the amount applied. Samples 3 and 4 received one makeup only. Sample 5 initially received two make/breaks to test for galling resistance before final makeup, No galling was observed. Later, three additional make/breaks were performed with no pin end collapse and galling over 1/2 a thread occurring on one of the breakouts. During the make/break tests, the stabbing and hand tight makeup of the WW connection was found to be very easy and trouble free. There was no tendency to crossthread, even when stabbed at an angle, and it screwed together very smoothly up to hand tight. During power tight makeup, there was no heat generated in the box (as checked by hand contact) and no jerkiness associated with any of the makeups or breakouts. Sample 2 was tested in pure compression. The maximum load obtained was 1,051 kips and the connection was beginning to significantly deform as the sample buckled. Actual pipe yield was 1,226 kips. Sample 3 was capped-end pressure tested to failure. The capped-end yield pressure of the pipe was 16,572 psi and the sample began to leak at 12,000 psi. Sample 4 was tested in pure tension. The maximum load obtained was 978 kips and the connection failed by fracture at the pin critical section. Actual pipe yield was 1,226 kips. Sample 5 was tested in combined tension/compression and internal gas pressure. The sample was assembled, setup and tested four times. The first time was with a torque of 7,298 ft-lbs and the connection leaked halfway to ISO Load Point 2 with loads of 693 kips and 4,312 psi. The second time the torque was increased to 14,488 ft-lbs and a leak occurred at 849 kips and 9,400 psi, which was ISO Load Point 2. The third time the makeup torque was again increased, to 20,456 ft-lbs, and a leak occurred at 716 kips and 11,342 psi, ISO Load Point 4. The fourth test was with the same torque as before, 20,617 ft-lbs, and the connection successfully tested up to load step 56, ISO Load Point 6 (second round) before leaking at 354 kips and 11,876 psi. At this point,

John D. Watts

2000-02-01T23:59:59.000Z

110

Evaluating aeroshell materials for the MJS/multi-hundred watt heat source. [Reentry survival from an aborted launch  

DOE Green Energy (OSTI)

In order to evaluate the possibility of improving upon an existing aeroshell design for the Multi-Hundred Watt power source, a trade-off study was conducted on a variety of candidate aeroshell materials. Mariner Jupiter/Saturn mission requirements and aeroshell material criteria were established to form a basis for the evaluation. Material data searches and reentry analyses were made to permit preparation of a quantitative comparison matrix. Depending upon the designer's constraints, either the well-known polycrystalline graphites (POCO-AXF-5Q, ATJS) or the more complex composite materials (AVCO 3D C/C, Pyrocarb-406) may be chosen.

Bennett, G.L.; Hagan, J.C.; Tantino, D.C.

1976-07-01T23:59:59.000Z

111

Town of Bargersville, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Bargersville, Indiana (Utility Company) Bargersville, Indiana (Utility Company) Jump to: navigation, search Name Town of Bargersville Place Indiana Utility Id 1208 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial General Service Commercial Outdoor Lighting- 100 watt high pressure sodium Lighting Outdoor Lighting- 175 Watt Mercury Vapor Lighting Outdoor Lighting- 400 watt high pressure sodium Lighting Outdoor Lighting- 400 watt mercury vapor (directional) Lighting Outdoor Lighting- 400 watt mercury vapor (round) Lighting

112

Development testing of the two-watt RTG heat source and Hastelloy-S/T-111 alloy compatibility studies  

DOE Green Energy (OSTI)

The two-watt radioisotope thermoelectric generator heat source capsules were tested to determine their survivability under extreme environmental conditions: high external pressure, high impact, and high internal pressure. Test results showed that the capsules could withstand external pressures of 1,000 bars and impacts at velocities near 150 meters per second. However, the results of the internal pressure tests (stress-rupture) were not so favorable, possibly because of copper contamination, leading to a recommendation for additional testing. A material compatibility study examined the use of Hastelloy-S as a material to clad the tantalum strength member of the two-watt radioisotopic heat source. Test capsules were subjected to high temperatures for various lengths of time, then cross sectioned and examined with a scanning electron microscope. Results of the study indicate that Hastelloy-S would be compatible with the underlying alloy, not only at the normal operating temperatures of the heat source, but also when exposed to the much higher temperatures of a credible accident scenario.

Howell, E.I.; Teaney, P.E.

1993-09-29T23:59:59.000Z

113

Improved method for removing metal vapor from gas streams  

DOE Patents (OSTI)

This invention relates to a process for gas cleanup to remove one or more metallic contaminants present as vapor. More particularly, the invention relates to a gas cleanup process using mass transfer to control the saturation levels such that essentially no particulates are formed, and the vapor condenses on the gas passage surfaces. It addresses the need to cleanup an inert gas contaminated with cadmium which may escape from the electrochemical processing of Integral Fast Reactor (IFR) fuel in a hot cell. The IFR is a complete, self-contained, sodium-cooled, pool-type fast reactor fueled with a metallic alloy of uranium, plutonium and zirconium, and is equipped with a close-coupled fuel cycle. Tests with a model have shown that removal of cadmium from argon gas is in the order of 99.99%. The invention could also apply to the industrial cleanup of air or other gases contaminated with zinc, lead, or mercury. In addition, the invention has application in the cleanup of other gas systems contaminated with metal vapors which may be toxic or unhealthy.

Ahluwalia, R.K.; Im, K.H.

1994-09-19T23:59:59.000Z

114

It's Elemental - The Element Sodium  

NLE Websites -- All DOE Office Websites (Extended Search)

Neon Neon Previous Element (Neon) The Periodic Table of Elements Next Element (Magnesium) Magnesium The Element Sodium [Click for Isotope Data] 11 Na Sodium 22.98976928 Atomic Number: 11 Atomic Weight: 22.98976928 Melting Point: 370.95 K (97.80°C or 208.04°F) Boiling Point: 1156 K (883°C or 1621°F) Density: 0.97 grams per cubic centimeter Phase at Room Temperature: Solid Element Classification: Metal Period Number: 3 Group Number: 1 Group Name: Alkali Metal What's in a name? From the English word soda and from the Medieval Latin word sodanum, which means "headache remedy." Sodium's chemical symbol comes from the Latin word for sodium carbonate, natrium. Say what? Sodium is pronounced as SO-dee-em. History and Uses: Although sodium is the sixth most abundant element on earth and comprises

115

Heart of Texas Electric Coop | Open Energy Information  

Open Energy Info (EERE)

of Texas Electric Coop of Texas Electric Coop Jump to: navigation, search Name Heart of Texas Electric Coop Place Texas Utility Id 55982 Utility Location Yes Ownership C NERC ERCOT Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt High Pressure Sodium Bulb Lighting 1000 Watt High Pressure Sodium Bulb (Closed Rate) Lighting 175 Watt Mercury Vapor Bulb (Closed Rate) Lighting 175 Watt Mercury Vapor Bulb (Closed Rate) - street lighting Lighting 400 Watt High Pressure Sodium Bulb (Closed Rate) Lighting Commercial Single Phase <24.99 KW Commercial

116

Image Storage in Hot Vapors  

E-Print Network (OSTI)

We theoretically investigate image propagation and storage in hot atomic vapor. A $4f$ system is adopted for imaging and an atomic vapor cell is placed over the transform plane. The Fraunhofer diffraction pattern of an object in the object plane can thus be transformed into atomic Raman coherence according to the idea of ``light storage''. We investigate how the stored diffraction pattern evolves under diffusion. Our result indicates, under appropriate conditions, that an image can be reconstructed with high fidelity. The main reason for this procedure to work is the fact that diffusion of opposite-phase components of the diffraction pattern interfere destructively.

Zhao, L; Xiao, Y; Yelin, S F

2007-01-01T23:59:59.000Z

117

Image Storage in Hot Vapors  

E-Print Network (OSTI)

We theoretically investigate image propagation and storage in hot atomic vapor. A $4f$ system is adopted for imaging and an atomic vapor cell is placed over the transform plane. The Fraunhofer diffraction pattern of an object in the object plane can thus be transformed into atomic Raman coherence according to the idea of ``light storage''. We investigate how the stored diffraction pattern evolves under diffusion. Our result indicates, under appropriate conditions, that an image can be reconstructed with high fidelity. The main reason for this procedure to work is the fact that diffusion of opposite-phase components of the diffraction pattern interfere destructively.

L. Zhao; T. Wang; Y. Xiao; S. F. Yelin

2007-10-22T23:59:59.000Z

118

Coal desulfurization with sodium hypochlorite.  

E-Print Network (OSTI)

??Wet desulfurization of Pittsburgh No. 8 coal and Illinois No. 6 coal were conducted with sodium hypochlorite in the laboratory. Pittsburgh No. 8 coal was (more)

Li, Wei, M.S.

2004-01-01T23:59:59.000Z

119

Town of Selma, North Carolina (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Selma Selma Place North Carolina Utility Id 16914 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes ISO Other Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 W Sodium Vapor/ Semi-enclosed Lighting AREA LIGHTING - 22,000 Lumen Sodium Vapor Lighting AREA LIGHTING - 250 Watt HPS Lighting AREA LIGHTING - 250 Watt HPS with decorative pole Lighting AREA LIGHTING - 27,500 Lumen Sodium Vapor Colbra-head Lighting AREA LIGHTING - 27,500 Lumen Sodium Vapor Flood Lighting AREA LIGHTING - 400 Watt HPS with decorative pole Lighting

120

Task 5: TVA sediment-disturbing activities within the Watts Bar Reservoir and Melton Hill Reservoir areas of the Clinch River  

DOE Green Energy (OSTI)

The objectives of Task 5 of the Interagency Agreement No. DE-AI05-91OR22007 were to review: (1) the extent of dredging, construction, and other sediment-disturbing activities conducted by the Tennessee Valley Authority (TVA) in potentially contaminated areas of Watts Bar Reservoir, and (2) the disposition of the materials from these activities. This memorandum is the final report for Task 5. This memorandum describes major activities in the Watts Bar Reservoir and Melton Hill Reservoir areas of the Clinch River that possibly resulted in significant disturbance of potentially contaminated sediments. TVA records from the construction of Watts Bar Dam, Kingston Fossil Plant, and Melton Hill Dam were reviewed to facilitate qualitative description of the effect of these activities in disturbing potentially contaminated sediments. The critical period for these activities in disturbing contaminated sediments was during or after 1956 when the peak releases of radioactive contaminants occurred from the Oak Ridge Reservation.

NONE

1997-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Part 70 License NRC Docket No. 70-07018 Subject: References: SUPPLEMENT TO APPLICATION FOR A SPECIAL NUCLEAR MATERIAL LICENSE FOR WATTS BAR NUCLEAR PLANT UNIT 2 IN ACCORDANCE  

E-Print Network (OSTI)

(TAC NO. ME0853)" As part of TVA's application for a Special Nuclear Material (SNM) License for Watts Bar Unit 2

Watts Bar; Nuclear Plant; Watts Bar; Nuclear Plant

2009-01-01T23:59:59.000Z

122

Atomic vapor laser isotope separation process  

DOE Patents (OSTI)

A laser spectroscopy system is utilized in an atomic vapor laser isotope separation process. The system determines spectral components of an atomic vapor utilizing a laser heterodyne technique. 23 figs.

Wyeth, R.W.; Paisner, J.A.; Story, T.

1990-08-21T23:59:59.000Z

123

Distribution of Tropical Tropospheric Water Vapor  

Science Conference Proceedings (OSTI)

Utilizing a conceptual model for tropical convection and observational data for water vapor, the maintenance of the vertical distribution of the tropical tropospheric water vapor is discussed. While deep convection induces large-scale subsidence ...

De-Zheng Sun; Richard S. Lindzen

1993-06-01T23:59:59.000Z

124

Atmospheric Water Vapor Characteristics at 70N  

Science Conference Proceedings (OSTI)

Using an extensive rawinsonde archive, characteristics of Arctic water vapor and its transports at 70N are examined for the period 19741991. Monthly-mean profiles and vertically integrated values of specific humidity and meridional vapor fluxes ...

Mark C. Serreze; Roger G. Barry; John E. Walsh

1995-04-01T23:59:59.000Z

125

Vapor Pressure Measurement of Supercooled Water  

Science Conference Proceedings (OSTI)

A new dewpoint hygrometer was developed for subfreezing temperature application. Vapor pressure of supercooled water was determined by measuring temperatures at the dew-forming surface and the vapor source ice under the flux density balance, and ...

N. Fukuta; C. M. Gramada

2003-08-01T23:59:59.000Z

126

High efficiency vapor-fed AMTEC system for direct conversion. Final report  

DOE Green Energy (OSTI)

The Alkali Metal Thermal to Electric Converter (AMTEC) is a high temperature, high efficiency system for converting thermal to electrical energy, with no moving parts. It is based on the unique properties of {beta}{double_prime}-alumina solid electrolyte (BASE), which is an excellent conductor of sodium ions, but an extremely poor conductor of electrons. When the inside of the BASE is maintained at a higher temperature and pressure, a concentration gradient is created across the BASE. Electrons and sodium atoms cannot pass through the BASE. However, the sodium atoms are ionized, and the sodium ions move through the BASE to the lower potential (temperature) region. The electrons travel externally to the AMTEC cell, providing power. There are a number of potential advantages to a wick-pumped, vapor-fed AMTEC system when compared with other designs. A wick-pumped system uses capillary forces to passively return liquid to the evaporator, and to distribute the liquid in the evaporator. Since the fluid return is self-regulating, multiple BASE tubes can use a single remote condenser, potentially improving efficiency in advanced AMTEC designs. Since the system is vapor-fed, sodium vapor is supplied at a uniform temperature and flux to the BASE tube, even with non-uniform heat fluxes and temperatures at the evaporator. The primary objective of the Phase 2 program was to develop wick-pumped AMTEC cells. During the program, procedures to fabricate wicks with smaller pore sizes were developed, to allow operation of an AMTEC cell at 800 C. A revised design was made for a High-Temperature, Wick-Fed AMTEC cell. In addition to the smaller wick pore size, several other changes were made to increase the cell efficiency: (1) internal artery return of condensate; (2) high temperature electrical feedthrough; and (3) separate heat pipe for providing heat to the BASE.

Anderson, W.G.; Bland, J.J.

1997-05-23T23:59:59.000Z

127

Vapor phase modifiers for oxidative coupling  

DOE Patents (OSTI)

Volatilized metal compounds retard vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, Barbara K. (Charleston, WV)

1991-01-01T23:59:59.000Z

128

LOW PRESSURE CHEMICAL VAPOR DEPOSITION OF POLYSILICON  

E-Print Network (OSTI)

THEORY The mass transport processes in low pressure chemical vapor deposition (LPCVD) are similar to those occuring in catalytic reactors

Gieske, R.J.

2011-01-01T23:59:59.000Z

129

City of Greendale, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Greendale, Indiana (Utility Company) Greendale, Indiana (Utility Company) Jump to: navigation, search Name City of Greendale Place Indiana Utility Id 6907 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service Commercial Flasher Signal Lighting Municipal street light service - 100 Watt Sodium Vapor Lighting Municipal street light service - 175 Watt Mercury Vapor Lighting Municipal street light service - 250 Watt Mercury Vapor Lighting Municipal street light service - 250 Watt Sodium Vapor Lighting

130

100-WATT CURIUM-242 FUELED THERMOELECTRIC GENERATOR--CONCEPTUAL DESIGN. SNAP Subtask 5.7 Final Report  

SciTech Connect

A thermoelectric generator which produces 100 watts of electrical power continuously over a six-month operational life in a space environment was designed. It employs the heat produced by the decay of Cm/sup 24/ as the source of power. Uniform output over the operational life of the generator is accomplished by means of a thermally actuated shutter which maintains the hot junction temperature of the thermoelectric conventer at a constunt figure by varying the amount of surplus heat which is radiated directly to space from the heat source. The isotopic heat source is designed to safely contain the Cm/sup 242/ under conditions of launch pad abont and rocket failure, but to burn up upon re-entry to the earth's atmosphere from orbital velocity. (W.L.H.)

Weddell, J.B.; Bloom, J.

1960-05-01T23:59:59.000Z

131

Vapor Pressures and Heats of Vaporization of Primary Coal Tars  

Office of Scientific and Technical Information (OSTI)

/ PC92544-18 / PC92544-18 VAPOR PRESSURES AND HEATS OF VAPORIZATION OF PRIMARY COAL TARS FINAL REPORT Grant Dates: August, 1992 - November, 1996 Principal Authors: Eric M. Suuberg (PI) and Vahur Oja Report Submitted: April, 1997 Revised: July, 1997 Grant Number: DE-FG22-92PC92544 Report Submitted by: ERIC M. SUUBERG DIVISION OF ENGINEERING BROWN UNIVERSITY PROVIDENCE, RI 02912 TEL. (401) 863-1420 Prepared For: U. S. DEPT. OF ENERGY FEDERAL ENERGY TECHNOLOGY CENTER P.O. BOX 10940 PITTSBURGH, PA 15236 DR. KAMALENDU DAS, FETC, MORGANTOWN , WV TECHNICAL PROJECT OFFICER "US/DOE Patent Clearance is not required prior to the publication of this document" ii United States Government Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any

132

Simulation of sodium boiling experiments with THERMIT sodium version  

E-Print Network (OSTI)

Natural and forced convection experiments(SBTF and French) are simulated with the sodium version of the thermal-hydraulic computer code THERMIT. Simulation is done for the test secti- -on with the pressure-velocity boundary ...

Huh, Kang Yul

1982-01-01T23:59:59.000Z

133

Means and method for vapor generation  

DOE Patents (OSTI)

A liquid, in heat transfer contact with a surface heated to a temperature well above the vaporization temperature of the liquid, will undergo a multiphase (liquid-vapor) transformation from 0% vapor to 100% vapor. During this transition, the temperature driving force or heat flux and the coefficients of heat transfer across the fluid-solid interface, and the vapor percentage influence the type of heating of the fluid--starting as "feedwater" heating where no vapors are present, progressing to "nucleate" heating where vaporization begins and some vapors are present, and concluding with "film" heating where only vapors are present. Unstable heating between nucleate and film heating can occur, accompanied by possibly large and rapid temperature shifts in the structures. This invention provides for injecting into the region of potential unstable heating and proximate the heated surface superheated vapors in sufficient quantities operable to rapidly increase the vapor percentage of the multiphase mixture by perhaps 10-30% and thereby effectively shift the multiphase mixture beyond the unstable heating region and up to the stable film heating region.

Carlson, Larry W. (Oswego, IL)

1984-01-01T23:59:59.000Z

134

Water simulation of sodium reactors  

Science Conference Proceedings (OSTI)

The thermal hydraulic simulation of a large sodium reactor by a scaled water model is examined. The Richardson Number, friction coefficient and the Peclet Number can be closely matched with the water system at full power and the similarity is retained for buoyancy driven flows. The simulation of thermal-hydraulic conditions in a reactor vessel provided by a scaled water experiment is better than that by a scaled sodium test. Results from a correctly scaled water test can be tentatively extrapolated to a full size sodium system.

Grewal, S.S.; Gluekler, E.L.

1981-06-28T23:59:59.000Z

135

Low-Pressure Sodium Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Low-pressure sodium lighting provides more energy-efficient outdoor lighting than high-intensity discharge lighting, but it has very poor color rendition. Typical applications include highway and...

136

Summary report on water quality, sediment and water chemistry data for water and sediment samples collected from source areas to Melton Hill and Watts Bar reservoirs  

Science Conference Proceedings (OSTI)

Contamination of surface water and sediments in the Clinch River and Watts Bar Reservoir (CR/WBR) system as a result of past and present activities by the US Department of Energy (DOE) on the Oak Ridge Reservation (ORR) and also activities by non-ORR facilities are being studied by the Clinch River Environmental Restoration Program (CR-ERP). Previous studies have documented the presence of heavy metals, organics, and radionuclides in the sediments of reservoirs in the vicinity. In support of the CR-ERP, during the summer of 1991, TVA collected and evaluated water and sediment samples from swimming areas and municipal water intakes on Watts Bar Reservoir, Melton Hill Reservoir (which is considered part of the Clinch River and Watts Bar Reservoir System), and Norris Reservoir, which was considered a source of less-contaminated reference or background data. Results of this study indicated that the levels of contamination in the samples from the Watts Bar and Melton Hill Reservoir sites did not pose a threat to human health. Despite the numerous studies, until the current work documented by this report, relatively few sediment or water samples had been collected by the CR-ERP in the immediate vicinity of contaminant point sources. This work focused on water and sediment samples taken from points immediately downstream from suspected effluent point sources both on and off the ORR. In August and September, 1994, TVA sampled surface water and sediment at twelve locations in Melton Hill and Watts Bar Reservoirs. Eleven of the sampling sites were selected based on existence of pollutant discharge permits, known locations of hazardous waste sites, and knowledge of past practices. The twelfth sample site was selected as a relatively less contaminated reference site for comparison purposes.

Tomaszewski, T.M.; Bruggink, D.J.; Nunn, D.L.

1995-08-01T23:59:59.000Z

137

Effect of test conditions and sample configuration on the AMTEC electrode/electrolyte characteristics measurements in the Sodium Exposure Test Cell experiment  

E-Print Network (OSTI)

An experimental investigation was conducted to determine the effect of test conditions and sample configuration on the AMTEC electrode/electrolyte characteristic measurements in a Sodium Exposure Test Cell (SETC). The effect of test conditions was determined by identifying the accurate correlation between sodium temperature and vapor pressure in the correct temperature range for the SETC. In addition, temperature distribution in the sodium source in SETC was determined. A correlation was identified that accurately predicted the relationship between the sodium vapor source temperature and the vapor pressure. A means to maintain the uniformity of the temperature across the electrode/electrolyte sample and in the sodium vapor source was determined. Two electrode/electrolyte configurations (tube and disk) were tested to determine if there was a difference in the characteristics determined from the measurements. It was demonstrated that the configuration of the sample had little effect (about 15%) on the measurements at typical AMTEC operating temperatures. Electrochemical Impedance Spectroscopy (EIS) and controlled potential current-voltage curves (iV curves) techniques were used to determine these characteristics.

Azimov, Ulughbek Bakhadirovich

2001-01-01T23:59:59.000Z

138

Vapor-Particle Separation Using Microporous Metallic Membrane in Crossflow Filtration  

SciTech Connect

Simultaneous separation of vapor and particles in industrial processes could be a key step toward manufacturing of high-quality goods. The separation is critical for successful measurement of volatile or semi-volatile aerosol particles, which no reliable technique exists. We have developed a technique for separation of vapor and particles simultaneously using a specialty microporous metallic membrane. The separator allows the thermally denuded particles traverse straight through the membrane tube, while the vapor molecules permeate through the membrane, separate from the particles and are removed subsequently. The separation technique virtually eliminates the possibility of contamination by vapor re- condensation. We tested the prototype of the vapor-particle separator (VPS) using aerosols prepared from sodium chloride to represent non-volatile aerosols. Chemical like dioctyl phthalate was chosen to represent volatile particles. The test aerosol particles were generated by an atomizer followed by a tandem differential mobility analyser to produce a stream of monodisperse particles in the size range of 10 to 100 nm. In real world particles, we tested the VPS using diesel engine particles that is a mixture of complex chemical composition. Number concentration of the nonvolatile particles reduced as the temperature increased, but the mode diameter of the aerosol population remained unchanged. Number concentration of the volatile particles was also reduced as the temperature increased, but their mode diameters became smaller as particles shrunk in diameter. Differences in the thermal behaviour of the particles were attributed to its transition energy barrier and evaporation rate. Mass balance analysis suggests the separation of vapor and test particles was reasonably complete. Thus, we conclude the VPS could provide an effective means for quantitative characterization of aerosol volatility and separation of vapors from particles.

Cheng, Mengdawn [ORNL

2013-01-01T23:59:59.000Z

139

Vapor phase heat transport systems  

DOE Green Energy (OSTI)

Vapor phase heat-transport systems are being tested in two of the passive test cells at Los Alamos. The systems consist of an active fin-and-tube solar collector and a condenser inside a water storage tank. The refrigerant, R-11, can be returned to the collector by a pump or by a self-pumping scheme. In one of the test cells the liquid was self-pumped to the roof-mounted collector 17 ft above the condenser. A mechanical valve was designed and tested that showed that the system could operate in a completely passive mode. Performance comparisons have been made with a passive water wall test cell.

Hedstrom, J.C.

1984-01-01T23:59:59.000Z

140

Data:9b11a6a4-b93e-48bf-8860-1d22715f115f | Open Energy Information  

Open Energy Info (EERE)

-b93e-48bf-8860-1d22715f115f -b93e-48bf-8860-1d22715f115f No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-400 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Data:D32b9210-612f-484b-888b-4eb9cb43e3da | Open Energy Information  

Open Energy Info (EERE)

612f-484b-888b-4eb9cb43e3da 612f-484b-888b-4eb9cb43e3da No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-400 W SV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

142

Data:B1abc200-9467-4663-ad52-ef845d920429 | Open Energy Information  

Open Energy Info (EERE)

abc200-9467-4663-ad52-ef845d920429 abc200-9467-4663-ad52-ef845d920429 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-100 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

143

Coupling apparatus for a metal vapor laser  

DOE Patents (OSTI)

Coupling apparatus for a large bore metal vapor laser is disclosed. The coupling apparatus provides for coupling high voltage pulses (approximately 40 KV) to a metal vapor laser with a high repetition rate (approximately 5 KHz). The coupling apparatus utilizes existing thyratron circuits and provides suitable power input to a large bore metal vapor laser while maintaining satisfactory operating lifetimes for the existing thyratron circuits.

Ball, D.G.; Miller, J.L.

1993-02-23T23:59:59.000Z

144

Mercury Vapor (Kooten, 1987) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor (Kooten, 1987) Mercury Vapor (Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor (Kooten, 1987) Exploration Activity Details Location Unspecified Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Surface soil-mercury surveys are an inexpensive and useful exploration tool for geothermal resources. ---- Surface geochemical surveys for mercury were conducted in 16 areas in 1979-1981 by ARCO Oil and Gas Company as part of its geothermal evaluation program. Three techniques used together have proved satisfactory in evaluating surface mercury data. These are contouring, histograms and cumulative frequency plots of the data. Contouring geochemical data and constructing histograms are standard

145

Vapor phase modifiers for oxidative coupling  

DOE Patents (OSTI)

Volatilized metal compounds are described which are capable of retarding vapor phase alkane conversion reactions in oxidative coupling processes that convert lower alkanes to higher hydrocarbons.

Warren, B.K.

1991-12-17T23:59:59.000Z

146

Thermoplastic Composite with Vapor Grown Carbon Fiber.  

E-Print Network (OSTI)

??Vapor grown carbon fiber (VGCF) is a new class of highly graphitic carbon nanofiber and offers advantages of economy and simpler processing over continuous-fiber composites. (more)

Lee, Jaewoo

2005-01-01T23:59:59.000Z

147

Moisture Durability of Vapor Permeable Insulating Sheathing ...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Existing Homes, Building Technologies Office (BTO) In this project, Building America team Building Science Corporation researched some of the ramifications of using exterior, vapor...

148

Water Vapor Fields Deduced from METEOSAT-1 Water Vapor Channel Data  

Science Conference Proceedings (OSTI)

A quasi-operational process for the determination of water vapor fields from METEPSAT-1 water vapor channel data is described. Each count of the WV picture is replaced by the corresponding mean relative humidity value using both the calibration ...

M. M. Poc; M. Roulleau

1983-09-01T23:59:59.000Z

149

Near real time vapor detection and enhancement using aerosol adsorption  

DOE Patents (OSTI)

A vapor sample detection method where the vapor sample contains vapor and ambient air and surrounding natural background particles. The vapor sample detection method includes the steps of generating a supply of aerosol that have a particular effective median particle size, mixing the aerosol with the vapor sample forming aerosol and adsorbed vapor suspended in an air stream, impacting the suspended aerosol and adsorbed vapor upon a reflecting element, alternatively directing infrared light to the impacted aerosol and adsorbed vapor, detecting and analyzing the alternatively directed infrared light in essentially real time using a spectrometer and a microcomputer and identifying the vapor sample.

Novick, Vincent J.; Johnson, Stanley A.

1997-12-01T23:59:59.000Z

150

G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) Value-Added Product  

SciTech Connect

The G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) value-added product (VAP) computes precipitable water vapor using neural network techniques from data measured by the GVR. The GVR reports time-series measurements of brightness temperatures for four channels located at 183.3 1, 3, 7, and 14 GHz.

Koontz, A; Cadeddu, M

2012-12-05T23:59:59.000Z

151

NREL: Awards and Honors - High-Rate Vapor Transport Deposition...  

NLE Websites -- All DOE Office Websites (Extended Search)

modules. In its first year of production, the technology has helped First Solar cut the price of PV modules to 2.50 per watt. The potential is even greater. A second-generation...

152

Technical Information on the Carbonation of the EBR-II Reactor, Summary Report Part 2: Application to EBR-II Primary Sodium System and Related Systems  

DOE Green Energy (OSTI)

Residual sodium is defined as sodium metal that remains behind in pipes, vessels, and tanks after the bulk sodium metal has been melted and drained from such components. The residual sodium has the same chemical properties as bulk sodium, and differs from bulk sodium only in the thickness of the sodium deposit. Typically, sodium is considered residual when the thickness of the deposit is less than 5-6 cm. This residual sodium must be removed or deactivated when a pipe, vessel, system, or entire reactor is permanently taken out of service, in order to make the component or system safer and/or to comply with decontamination and decomissioning regulations. As an alternative to the established residual sodium deactivation techniques (steam-and-nitrogen, wet vapor nitrogen, etc.), a technique involving the use of moisture and carbon dioxide has been developed. With this technique, sodium metal is converted into sodium bicarbonate by reacting it with humid carbon dioxide. Hydrogen is emitted as a by-product. This technique was first developed in the laboratory by exposing sodium samples to humidifed carbon dioxide under controlled conditions, and then demonstrated on a larger scale by treating residual sodium within the Experimental Breeder Reactor II (EBR-II) secondary cooling system, followed by the primary cooling system, respectively. The EBR-II facility is located at the Idaho National Laboratory (INL) in southeastern Idaho, USA. This report is Part 2 of a two-part report. This second report provides a supplement to the first report and describes the application of the humdidified carbon dioxide technique ("carbonation") to the EBR-II primary tank, primary cover gas systems, and the intermediate heat exchanger. Future treatment plans are also provided.

Steven R. Sherman; Collin J. Knight

2006-03-01T23:59:59.000Z

153

Quantitative organic vapor-particle sampler  

DOE Patents (OSTI)

A quantitative organic vapor-particle sampler for sampling semi-volatile organic gases and particulate components. A semi-volatile organic reversible gas sorbent macroreticular resin agglomerates of randomly packed microspheres with the continuous porous structure of particles ranging in size between 0.05-10 .mu.m for use in an integrated diffusion vapor-particle sampler.

Gundel, Lara (Berkeley, CA); Daisey, Joan M. (Walnut Creek, CA); Stevens, Robert K. (Cary, NC)

1998-01-01T23:59:59.000Z

154

A New Global Water Vapor Dataset  

Science Conference Proceedings (OSTI)

A comprehensive and accurate global water vapor dataset is critical to the adequate understanding of water vapor's role in the earth's climate system. To begin to satisfy this need, the authors have produced a blended dataset made up of global, 5-...

David L. Randel; Thomas J. Greenwald; Thomas H. Vonder Haar; Graeme L. Stephens; Mark A. Ringerud; Cynthia L. Combs

1996-06-01T23:59:59.000Z

155

LNG fire and vapor control system technologies  

SciTech Connect

This report provides a review of fire and vapor control practices used in the liquefied natural gas (LNG) industry. Specific objectives of this effort were to summarize the state-of-the-art of LNG fire and vapor control; define representative LNG facilities and their associated fire and vapor control systems; and develop an approach for a quantitative effectiveness evaluation of LNG fire and vapor control systems. In this report a brief summary of LNG physical properties is given. This is followed by a discussion of basic fire and vapor control design philosophy and detailed reviews of fire and vapor control practices. The operating characteristics and typical applications and application limitations of leak detectors, fire detectors, dikes, coatings, closed circuit television, communication systems, dry chemicals, water, high expansion foam, carbon dioxide and halogenated hydrocarbons are described. Summary descriptions of a representative LNG peakshaving facility and import terminal are included in this report together with typical fire and vapor control systems and their locations in these types of facilities. This state-of-the-art review identifies large differences in the application of fire and vapor control systems throughout the LNG industry.

Konzek, G.J.; Yasutake, K.M.; Franklin, A.L.

1982-06-01T23:59:59.000Z

156

Atomic vapor laser isotope separation  

SciTech Connect

Atomic vapor laser isotope separation (AVLIS) is a general and powerful technique. A major present application to the enrichment of uranium for light-water power reactor fuel has been under development for over 10 years. In June 1985 the Department of Energy announced the selection of AVLIS as the technology to meet the nation's future need for the internationally competitive production of uranium separative work. The economic basis for this decision is considered, with an indicated of the constraints placed on the process figures of merit and the process laser system. We then trace an atom through a generic AVLIS separator and give examples of the physical steps encountered, the models used to describe the process physics, the fundamental parameters involved, and the role of diagnostic laser measurements.

Stern, R.C.; Paisner, J.A.

1985-11-08T23:59:59.000Z

157

ARM - Field Campaign - Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 2000.09.18 - 2000.10.08 Lead Scientist : Henry Revercomb Data Availability Yes For data sets, see below. Description Scientific hypothesis: 1. Microwave radiometer (MWR) observations of the 22 GHz water vapor line can accurately constrain the total column amount of water vapor (assuming a calibration accuracy of 0.5 degC or better, which translates into 0.35 mm PWV). 2. Continuous profiling by Raman lidar provides a stable reference for handling sampling problems and observes a fixed column directly above the site only requiring a single height- independent calibration factor. 3. Agreement between the salt-bath calibrated in-situ probes, chilled

158

Vacuum pyrolysis of sodium stearate  

DOE Green Energy (OSTI)

Vacuum pyrolysis of sodium stearate was studied to provide useful information for Green River oil shale pyrolysis. Sodium stearate is a typical compound of carboxylic acid salts amounting to 3.6% of total organic materials in the oil shale by methanol extraction. Sodium stearate contained in a stainless steel miniature reactor was heated at 450/sup 0/C in a fluidized sand bath. Pyrolysis times ranged from 15 to 120 minutes. The amounts of gas and liquid products were measured and composition determined by gas chromatography. Ethane, methane, propylene plus propane, hydrogen, carbon dioxide, and carbon monoxide are the major gaseous products, in order of decreasing concentration. The predominant liquid product is a C/sub 17/ alkene with C/sub 12/-C/sub 21/ alkene/alkane pairs present. The first order decomposition rate constant for sodium stearate at 450/sup 0/C was calculated to be 6.4 x 10/sup -3/ min./sup -1/. 18 refs., 7 figs.

Chong, S.L.

1985-09-01T23:59:59.000Z

159

Seal for sodium sulfur battery  

SciTech Connect

This invention is directed to a seal for a sodium sulfur battery in which the sealing is accomplished by a radial compression seal made on a ceramic component of the battery which separates an anode compartment from a cathode compartment of the battery.

Topouzian, Armenag (Birmingham, MI); Minck, Robert W. (Lathrup Village, MI); Williams, William J. (Northville, MI)

1980-01-01T23:59:59.000Z

160

Volume efficient sodium sulfur battery  

SciTech Connect

In accordance with the teachings of this specification, a sodium sulfur battery is formed as follows. A plurality of box shaped sulfur electrodes are provided, the outer surfaces of which are defined by an electrolyte material. Each of the electrodes have length and width dimensions substantially greater than the thicknesses thereof as well as upwardly facing surface and a downwardly facing surface. An electrode structure is contained in each of the sulfur electrodes. A holding structure is provided for holding the plurality of sulfur electrodes in a stacked condition with the upwardly facing surface of one sulfur electrode in facing relationship to the downwardly facing surface of another sulfur electrode thereabove. A small thickness dimension separates each of the stacked electrodes thereby defining between each pair of sulfur electrodes a volume which receives the sodium reactant. A reservoir is provided for containing sodium. A manifold structure interconnects the volumes between the sulfur electrodes and the reservoir. A metering structure controls the flow of sodium between the reservoir and the manifold structure.

Mikkor, Mati (Ann Arbor, MI)

1980-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Technical Information on the Carbonation of the EBR-II Reactor, Summary Report Part 1: Laboratory Experiments and Application to EBR-II Secondary Sodium System  

DOE Green Energy (OSTI)

Residual sodium is defined as sodium metal that remains behind in pipes, vessels, and tanks after the bulk sodium metal has been melted and drained from such components. The residual sodium has the same chemical properties as bulk sodium, and differs from bulk sodium only in the thickness of the sodium deposit. Typically, sodium is considered residual when the thickness of the deposit is less than 5-6 cm. This residual sodium must be removed or deactivated when a pipe, vessel, system, or entire reactor is permanently taken out of service, in order to make the component or system safer and/or to comply with decommissioning regulations. As an alternative to the established residual sodium deactivation techniques (steam-and-nitrogen, wet vapor nitrogen, etc.), a technique involving the use of moisture and carbon dioxide has been developed. With this technique, sodium metal is converted into sodium bicarbonate by reacting it with humid carbon dioxide. Hydrogen is emitted as a by-product. This technique was first developed in the laboratory by exposing sodium samples to humidified carbon dioxide under controlled conditions, and then demonstrated on a larger scale by treating residual sodium within the Experimental Breeder Reactor II (EBR-II) secondary cooling system, followed by the primary cooling system, respectively. The EBR-II facility is located at the Idaho National Laboratory (INL) in southeastern Idaho, U.S.A. This report is Part 1 of a two-part report. It is divided into three sections. The first section describes the chemistry of carbon dioxide-water-sodium reactions. The second section covers the laboratory experiments that were conducted in order to develop the residual sodium deactivation process. The third section discusses the application of the deactivation process to the treatment of residual sodium within the EBR-II secondary sodium cooling system. Part 2 of the report, under separate cover, describes the application of the technique to residual sodium treatment within the EBR-II primary sodium cooling system and related systems.

Steven R. Sherman

2005-04-01T23:59:59.000Z

162

A fixed granular-bed sorber for measurement and control of alkali vapors in PFBC (pressurized fluidized-bed combustion)  

SciTech Connect

Alkali vapors (Na and K) in the hot flue gas from the pressurized fluidized-bed combustion (PFBC) of coal could cause corrosion problems with the gas turbine blades. In a laboratory-scale PFBC test with Beulah lignite, a fixed granular bed of activated bauxite sorbent was used to demonstrate its capability for measuring and controlling alkali vapors in the PFBC flue gas. The Beulah lignite was combusted in a bed of Tymochtee dolomite at bed temperatures ranging from 850 to 875{degrees}C and a system pressure of 9.2 atm absolute. The time-averaged concentration of sodium vapor in the PFBC flue gas was determined from the analysis of two identical beds of activated bauxite and found to be 1.42 and 1.50 ppmW. The potassium vapor concentration was determined to be 0.10 ppmW. The sodium material balance showed that only 0.24% of the total sodium in the lignite was released as vapor species in the PFBC flue gas. This results in an average of 1.56 ppmW alkali vapors in the PFBC flue gas. This average is more than 1.5 orders of magnitude greater than the currently suggested alkali specification limit of 0.024 ppm for an industrial gas turbine. The adsorption data obtained with the activated bauxite beds were also analyzed mathematically by use of a LUB (length of unused bed)/equilibrium section concept. Analytical results showed that the length of the bed, L{sub o} in centimeters, relates to the break through time, {theta}{sub b} in hours, for the alkali vapor to break through the bed as follows: L{sub o} = 33.02 + 1.99 {theta}{sub b}. This formula provides useful information for the engineering design of fixed-bed activated bauxite sorbers for the measurement and control of alkali vapors in PFBC flue gas. 26 refs., 4 figs., 4 tabs.

Lee, S.H.D.; Swift, W.M.

1990-01-01T23:59:59.000Z

163

Energy Basics: Low-Pressure Sodium Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Low-Pressure Sodium Lighting Low-pressure sodium lighting provides more energy-efficient outdoor lighting than high-intensity discharge lighting, but it has very poor color...

164

Analytical and experimental simulation of boiling oscillations in sodium with a low-pressure water system. [LMFBR  

SciTech Connect

An experimental and analytical program designed to simulate sodium boiling under low-power, low-flow conditions has been completed. Experiments were performed using atmospheric- pressure water as a simulant fluid and a simple one-dimensional model was developed for the system. Results indicate that water is a suitable simulant for liquid sodium under certain conditions and that the model does a fair job of modeling the system. In addition, oscillations that occur during the boiling process appear to augment substantially the heat transfer between liquid and vapor in condensation.

Levin, A.E.; Griffith, P.

1981-01-01T23:59:59.000Z

165

Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) ...  

Open Energy Info (EERE)

Mercury Vapor At Desert Peak Area (Varekamp & Buseck, 1983) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Desert Peak Area...

166

Mercury Vapor At Socorro Mountain Area (Kooten, 1987) | Open...  

Open Energy Info (EERE)

Mercury Vapor At Socorro Mountain Area (Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Socorro Mountain Area...

167

Abstract: Apparatus for Measuring Vapor-Liquid Equilibrium ...  

Science Conference Proceedings (OSTI)

... Measurements of the vapor pressures and saturated liquid densities of ethanol and the vapor pressure of an ethanol water mixture (ethanol=0.6743 ...

168

Mercury Vapor At Mccoy Geothermal Area (DOE GTP) | Open Energy...  

Open Energy Info (EERE)

Mercury Vapor At Mccoy Geothermal Area (DOE GTP) Exploration Activity Details Location Mccoy Geothermal Area Exploration Technique Mercury Vapor Activity Date Usefulness not...

169

Protective tubes for sodium heated water tubes  

DOE Patents (OSTI)

A heat exchanger in which water tubes are heated by liquid sodium which minimizes the results of accidental contact between the water and the sodium caused by failure of one or more of the water tubes. A cylindrical protective tube envelopes each water tube and the sodium flows axially in the annular spaces between the protective tubes and the water tubes.

Essebaggers, Jan (39 Honeyman Dr., Succasunna, NJ 07876)

1979-01-01T23:59:59.000Z

170

Chloride substitution in sodium borohydride  

Science Conference Proceedings (OSTI)

The dissolution of sodium chloride and sodium borohydride into each other resulting in formation of solid solutions of composition Na(BH{sub 4}){sub 1-x}Cl{sub x} is studied. The dissolution reaction is facilitated by two methods: ball milling or combination of ball milling and annealing at 300 deg. C for three days of NaBH{sub 4}-NaCl samples in molar ratios of 0.5:0.5 and 0.75:0.25. The degree of dissolution is studied by Rietveld refinement of synchrotron radiation powder X-ray diffraction (SR-PXD) data. The results show that dissolution of 10 mol% NaCl into NaBH{sub 4}, forming Na(BH{sub 4}){sub 0.9}Cl{sub 0.1}, takes place during ball milling. A higher degree of dissolution of NaCl in NaBH{sub 4} is obtained by annealing resulting in solid solutions containing up to 57 mol% NaCl, i.e. Na(BH{sub 4}){sub 0.43}Cl{sub 0.57}. In addition, annealing results in dissolution of 10-20 mol% NaBH{sub 4} into NaCl. The mechanism of the dissolution during annealing and the decomposition pathway of the solid solutions are studied by in situ SR-PXD. Furthermore, the stability upon hydrogen release and uptake were studied by Sieverts measurements. - Graphical Abstract: Dissolution of sodium chloride and sodium borohydride into each other resulting in formation of solid solutions of composition Na(BH{sub 4}){sub 1-x}Cl{sub x} is studied. Dissolution is facilitated by two methods: ball milling or annealing at 300 deg. C for three days of NaBH{sub 4}-NaCl samples. Sample compositions and dissolution mechanism are studied by Rietveld refinement of synchrotron radiation powder X-ray diffraction data. Highlights: > Studies of dissolution of sodium chloride and sodium borohydride into each other. > Solid state diffusion facilitated by mechanical and thermal treatments. > Dissolution is more efficiently induced by heating than by mechanical treatment. > Mechanism for dissolution studied by Rietveld refinement of in situ SR-PXD data.

Ravnsbaek, Dorthe B.; Rude, Line H. [Center for Materials Crystallography (CMC), Interdisciplinary Nanoscience Center (iNANO), Department of Chemistry, Aarhus University, Langelandsgade 140, DK-8000 Arhus C (Denmark); Jensen, Torben R., E-mail: trj@chem.au.dk [Center for Materials Crystallography (CMC), Interdisciplinary Nanoscience Center (iNANO), Department of Chemistry, Aarhus University, Langelandsgade 140, DK-8000 Arhus C (Denmark)

2011-07-15T23:59:59.000Z

171

Water vapor retrieval over many surface types  

SciTech Connect

In this paper we present a study of of the water vapor retrieval for many natural surface types which would be valuable for multi-spectral instruments using the existing Continuum Interpolated Band Ratio (CIBR) for the 940 nm water vapor absorption feature. An atmospheric code (6S) and 562 spectra were used to compute the top of the atmosphere radiance near the 940 nm water vapor absorption feature in steps of 2.5 nm as a function of precipitable water (PW). We derive a novel technique called ``Atmospheric Pre-corrected Differential Absorption`` (APDA) and show that APDA performs better than the CIBR over many surface types.

Borel, C.C.; Clodius, W.C.; Johnson, J.

1996-04-01T23:59:59.000Z

172

Modeling engine oil vaporization and transport of the oil vapor in the piston ring pack on internal combustion engines.  

E-Print Network (OSTI)

??A model was developed to study engine oil vaporization and oil vapor transport in the piston ring pack of internal combustion engines. With the assumption (more)

Cho, Yeunwoo, 1973-

2004-01-01T23:59:59.000Z

173

Analysis of binary vapor turbines  

DOE Green Energy (OSTI)

The effect the binary mixture has on the turbine is examined in terms of design and cost. Several flow theories for turbines and turbine blading are reviewed. The similarity method, which uses dimensionless parameters, is used in determining rotative speeds and diameters for a variety of inlet temperatures and exit pressures. It is shown that the ratio of exit to inlet specific volume for each component in the mixture is the same for each specie. The specific volume ratio constraints are combined with the temperature equalities, the condenser pressure, and the total inlet entropy to form the constraints necessary to determine the exit state uniquely in an isentropic expansion. The non-isentropic exit state is found in a similar manner. The expansion process is examined for several cases and compared with the expansion of a single component vapor. Finally, in order to maintain high efficiency and to meet the criteria which makes the similarity method valid at high inlet temperatures, turbine multistaging is examined and a sample case is given for a two stage turbine.

Bliss, R.W.; Boehm, R.F.; Jacobs, H.R.

1976-12-01T23:59:59.000Z

174

Fire suppressing apparatus. [sodium fires  

DOE Patents (OSTI)

Apparatus for smothering a liquid sodium fire comprises a pan, a perforated cover on the pan, and tubed depending from the cover and providing communication between the interior of the pan and the ambient atmosphere through the perforations in the cover. Liquid caught in the pan rises above the lower ends of the tubes and thus serves as a barrier which limits the amount of air entering the pan.

Buttrey, K.E.

1980-12-19T23:59:59.000Z

175

Perfluorocarbon vapor tagging of blasting cap detonators  

DOE Patents (OSTI)

A plug for a blasting cap is made of an elastomer in which is dissolved a perfluorocarbon. The perfluorocarbon is released as a vapor into the ambient over a long period of time to serve as a detectable taggant.

Dietz, Russell N. (Shoreham, NY); Senum, Gunnar I. (Patchogue, NY)

1981-01-01T23:59:59.000Z

176

Perfluorocarbon vapor tagging of blasting cap detonators  

SciTech Connect

A plug for a blasting cap is made of an elastomer in which is dissolved a perfluorocarbon. The perfluorocarbon is released as a vapor into the ambient over a long period of time to serve as a detectable taggant.

Dietz, R.N.; Senum, G.I.

1981-03-17T23:59:59.000Z

177

Aerogel composites using chemical vapor infiltration  

NLE Websites -- All DOE Office Websites (Extended Search)

Aerogel composites using chemical vapor infiltration Aerogel composites using chemical vapor infiltration Title Aerogel composites using chemical vapor infiltration Publication Type Journal Article Year of Publication 1995 Authors Hunt, Arlon J., Michael R. Ayers, and Wanqing Cao Journal Journal of Non-Crystalline Solids Volume 185 Pagination 227-232 Abstract A new method to produce novel composite materials based on the use of aerogels as a starting material is described. Using chemical vapor infiltration, a variety of solid materials were thermally deposited into the open pore structure of aerogel. The resulting materials possess new and unusual properties including photoluminescence, magnetism and altered optical properties. An important characteristic of this preparation process is the very small size of the deposits that gives rise to new behaviors. Silicon deposits exhibit photoluminescence, indicating quantum confinement. Two or more phases may be deposited simultaneously and one or both chemically or thermally reacted to produce new structures.

178

Chemical vapor depositing of metal fluorides  

Science Conference Proceedings (OSTI)

High Purity BeF2 and BeF2AlF3glasses have been deposited by the chemical vapor deposition technique using beryllium and aluminum 1

A. Sarhangi; J. M. Power

1992-01-01T23:59:59.000Z

179

Chemical vapor deposition of antimicrobial polymer coatings  

E-Print Network (OSTI)

There is large and growing interest in making a wide variety of materials and surfaces antimicrobial. Initiated chemical vapor deposition (iCVD), a solventless low-temperature process, is used to form thin films of polymers ...

Martin, Tyler Philip, 1977-

2007-01-01T23:59:59.000Z

180

Chemical vapor deposition of functionalized isobenzofuran polymers  

E-Print Network (OSTI)

This thesis develops a platform for deposition of polymer thin films that can be further tailored by chemical surface modification. First, we explore chemical vapor deposition of functionalized isobenzofuran films using ...

Olsson, Ylva Kristina

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Tropospheric Water Vapor and Climate Sensitivity  

Science Conference Proceedings (OSTI)

Estimates are made of the effect of changes in tropospheric water vapor on the climate sensitivity to doubled carbon dioxide (CO2), using a coarse resolution atmospheric general circulation model coupled to a slab mixed layer ocean. The ...

Edwin K. Schneider; Ben P. Kirtman; Richard S. Lindzen

1999-06-01T23:59:59.000Z

182

Chemical vapor infiltration using microwave energy  

DOE Patents (OSTI)

This invention is comprised of a method for producing reinforced ceramic composite articles by means of chemical vapor infiltration and deposition in which an inverted temperature gradient is utilized. Microwave energy is the source of heat for the process.

Devlin, D.J.; Currier, R.P.; Laia, J.R.; Barbero, R.S.

1992-12-31T23:59:59.000Z

183

Multicomponent fuel vaporization at high pressures.  

DOE Green Energy (OSTI)

We extend our multicomponent fuel model to high pressures using a Peng-Robinson equation of state, and implement the model into KIVA-3V. Phase equilibrium is achieved by equating liquid and vapor fugacities. The latent heat of vaporization and fuel enthalpies are also corrected for at high pressures. Numerical simulations of multicomponent evaporation are performed for single droplets for a diesel fuel surrogate at different pressures.

Torres, D. J. (David J.); O'Rourke, P. J. (Peter J.)

2002-01-01T23:59:59.000Z

184

Lamar County Elec Coop Assn | Open Energy Information  

Open Energy Info (EERE)

Lamar County Elec Coop Assn Lamar County Elec Coop Assn Place Texas Utility Id 10649 Utility Location Yes Ownership C NERC Location TRE Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png LARGE COMMERCIAL Commercial LARGE COMMERCIAL PUBLIC BUILDINGS Commercial RESIDENTIAL & PUBLIC BUILDINGS Residential SMALL COMMERCIAL Commercial security light- 100 watt High Pressure Sodium Lighting security light- 400 watt Metal Halide Lighting security light-1000 watt Mercury Vapor Lighting security light-1000 watt Metal Halide Lighting security light-175 watt Mercury Vapor Lighting

185

Tippah Electric Power Assn | Open Energy Information  

Open Energy Info (EERE)

Tippah Electric Power Assn Tippah Electric Power Assn Place Mississippi Utility Id 18943 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GSA 1 General Power Rate 1 Commercial GSA 2 General Power Rate 2 Commercial GSA 3 General Power Rate 3 Commercial LS Lighting High Pressure Sodium 100 Watts Lighting LS Lighting Mercury Vapor 175 Watts Lighting LS Lighting Mercury Vapor 400 Watts Lighting LS Lighting Metal Halide Cobrahead 400 Watts Lighting LS Lighting Metal Halide Floodlight 1000 Watts Lighting

186

Urania vapor composition at very high temperatures  

SciTech Connect

Due to the chemically unstable nature of uranium dioxide its vapor composition at very high temperatures is, presently, not sufficiently studied though more experimental knowledge is needed for risk assessment of nuclear reactors. We used laser vaporization coupled to mass spectrometry of the produced vapor to study urania vapor composition at temperatures in the vicinity of its melting point and higher. The very good agreement between measured melting and freezing temperatures and between partial pressures measured on the temperature increase and decrease indicated that the change in stoichiometry during laser heating was very limited. The evolutions with temperature (in the range 2800-3400 K) of the partial pressures of the main vapor species (UO{sub 2}, UO{sub 3}, and UO{sub 2}{sup +}) were compared with theoretically predicted evolutions for equilibrium noncongruent gas-liquid and gas-solid phase coexistences and showed very good agreement. The measured main relative partial pressure ratios around 3300 K all agree with calculated values for total equilibrium between condensed and vapor phases. It is the first time the three main partial pressure ratios above stoichiometric liquid urania have been measured at the same temperature under conditions close to equilibrium noncongruent gas-liquid phase coexistence.

Pflieger, Rachel [Institute for Transuranium Elements, Joint Research Centre, European Commission, P.O. Box 2340, 76125 Karlsruhe (Germany); Marcoule Institute for Separation Chemistry (ICSM), UMR 5257, CEA-CNRS-UMII-ENSCM, Bagnols sur Ceze Cedex (France); Colle, Jean-Yves [Institute for Transuranium Elements, Joint Research Centre, European Commission, P.O. Box 2340, 76125 Karlsruhe (Germany); Iosilevskiy, Igor [Joint Institute for High Temperature, Russian Academy of Science, 125412 Moscow (Russian Federation); Moscow Institute of Physics and Technology, State University, 141700 Moscow (Russian Federation); Extreme Matter Institute (EMMI), 64291 Darmstadt (Germany); Sheindlin, Michael [Institute for Transuranium Elements, Joint Research Centre, European Commission, P.O. Box 2340, 76125 Karlsruhe (Germany); Joint Institute for High Temperature, Russian Academy of Science, 125412 Moscow (Russian Federation)

2011-02-01T23:59:59.000Z

187

Halifax Electric Member Corp | Open Energy Information  

Open Energy Info (EERE)

Halifax Electric Member Corp Halifax Electric Member Corp Place North Carolina Utility Id 7978 Utility Location Yes Ownership C NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png MEDIUM GENERAL SERVICE Commercial NC GREENPOWER PROGRAM voluntary RENEWABLE ENERGY GENERATION-Solar RENEWABLE ENERGY GENERATION-Wind RESIDENTIAL SERVICE Residential SECURITY LIGHTING 100-watt high-pressure sodium Lighting SECURITY LIGHTING 140-watt LED Light Commercial SECURITY LIGHTING 175-watt mercury vapor Lighting SECURITY LIGHTING 175-watt metal halide Lighting SECURITY LIGHTING 250-watt high-pressure sodium Lighting

188

Town of Etna Green, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Etna Green, Indiana (Utility Company) Etna Green, Indiana (Utility Company) Jump to: navigation, search Name Town of Etna Green Place Indiana Utility Id 5928 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 150 watt Hi-Pressure Sodium Lighting 1500 watt Quartz Lighting 175 watt Mercury Vapor Lighting 250 watt Hi-Pressure Sodium Lighting 400 watt Metal Halide Lighting General Service Rate Metered Demand - Single Phase Commercial General Service Rate Metered Demand - Three Phase Commercial General Service Rate for Non-residential "GS" - Single Phase Commercial

189

Safety Evaluation Report related to the operation of Watts Bar Nuclear Plant, Units 1 and 2 (Docket Nos. 50-390 and 50-391). Supplement No. 12  

Science Conference Proceedings (OSTI)

Supplement No. 12 to the Safety Evaluation Report for the application filed by the Tennessee Valley Authority for license to operate Watts Bar Nuclear Plant, Units 1 and 2, Docket Nos. 50-390 and 50-391, located in Rhea County, Tennessee, has been prepared by the Office of Nuclear Reactor Regulation of the Nuclear Regulatory Commission. The purpose of this supplement is to update the Safety Evaluation of (1) additional information submitted by the applicant since Supplement No. 11 was issued, and (2) matters that the staff had under review when Supplement No. 11 was issued.

Tam, P.S.

1993-10-01T23:59:59.000Z

190

City of Westerville, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name City of Westerville Place Westerville, Ohio Utility Id 20477 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Westerville, OH Smart Grid Project was awarded $4,320,000 Recovery Act Funding with a total project value of $10,663,000. Utility Rate Schedules Grid-background.png 175 watt mercury vapor light/100 watt high pressure sodium light(pole in place) Lighting 175 watt mercury vapor light/100 watt high pressure sodium light(city

191

Atchison-Holt Electric Coop | Open Energy Information  

Open Energy Info (EERE)

Atchison-Holt Electric Coop Atchison-Holt Electric Coop Jump to: navigation, search Name Atchison-Holt Electric Coop Place Missouri Utility Id 942 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes ISO Other Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 100 Watt Sodium Lighting 175 Watt Mercury Vapor Lighting 250 Watt Sodium Lighting 400 Watt Mercury Vapor Lighting Commercial Multi-Phase Commercial Commercial Single-Phase Commercial Industrial Multi-Phase Industrial Irrigation Multi-Phase Commercial

192

Bowie-Cass Electric Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Bowie-Cass Electric Coop, Inc Bowie-Cass Electric Coop, Inc Jump to: navigation, search Name Bowie-Cass Electric Coop, Inc Place Texas Utility Id 2049 Utility Location Yes Ownership C NERC Location SPP NERC SPP Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Large Power Service Commercial Industrial Large Power Service Industrial Residential Service Residential Schedule ADD-250 Watt High Pressure Sodium Lighting Schedule ADD-400 Watt Mercury vapor. Lighting Schedule DD-100 Watt High Pressure Sodium Lighting Schedule DD-175 Watt Mercury Vapor Lighting

193

City of Westerville, Ohio (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

(Redirected from City of Westerville, OH) (Redirected from City of Westerville, OH) Jump to: navigation, search Name City of Westerville Place Westerville, Ohio Utility Id 20477 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Westerville, OH Smart Grid Project was awarded $4,320,000 Recovery Act Funding with a total project value of $10,663,000. Utility Rate Schedules Grid-background.png 175 watt mercury vapor light/100 watt high pressure sodium light(pole in place) Lighting 175 watt mercury vapor light/100 watt high pressure sodium light(city

194

Southern Pine Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Elec Coop, Inc Elec Coop, Inc Jump to: navigation, search Name Southern Pine Elec Coop, Inc Place Alabama Utility Id 17646 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Security Light: 100 Watt High Pressure Sodium (HPS) Lighting Security Light: 175 Watt Mercury Vapor Lighting Security Light: 400 Watt High Pressure Sodium (HPS) Lighting Security Light: 400 Watt Mercury Vapor Lighting Average Rates Residential: $0.1140/kWh Commercial: $0.0956/kWh Industrial: $0.0928/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

195

Bridger Valley Elec Assn, Inc | Open Energy Information  

Open Energy Info (EERE)

Wyoming Wyoming Utility Id 2215 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Irrigation Pumping Industrial Large General Service Single Phase Industrial Large Power (350 kVA or less) Industrial Large Power (350 kVA to 2000 kVA) Industrial Large Power (Over 2000 kVA) Industrial Lighting Service-100 watt High Pressure Sodium Lighting Lighting Service-175 watt Mercury Vapor Lamp Lighting Lighting Service-250 watt High Pressure Sodium Lighting Lighting Service-400 watt Mercury Vapor Lamp Lighting

196

Sodium technology, 1972--1973  

SciTech Connect

References to 897 publications on sodium and NaK technology cited in Nuclear Science Abstracts Volume 26 (1972) through Volume 27 (1973 through June) are contained in this bibliography. Keyword indexing is displayed under each citation to provide information on the contents of the document. References are arranged in order by the original NSA abstract number which approximately places them in chronological order. Sequence numbers appear beside each reference, and the personal author index refers to these sequence numbers. The subject index refers to the original abstract numbers. (auth)

1974-02-01T23:59:59.000Z

197

Conceptual Design of a MEDE Treatment System for Sodium Bonded Fuel  

SciTech Connect

Unirradiated sodium bonded metal fuel and casting scrap material containing highly enriched uranium (HEU) is stored at the Materials and Fuels Complex (MFC) on the Idaho National Laboratory (INL). This material, which includes intact fuel assemblies and elements from the Fast Flux Test Facility (FFTF) and Experimental Breeder Reactor-II (EBR-II) reactors as well as scrap material from the casting of these fuels, has no current use under the terminated reactor programs for both facilities. The Department of Energy (DOE), under the Sodium-Bonded Spent Nuclear Fuel Treatment Record of Decision (ROD), has determined that this material could be prepared and transferred to an off-site facility for processing and eventual fabrication of fuel for commercial nuclear reactors. A plan is being developed to prepare, package and transfer this material to the DOE High Enriched Uranium Disposition Program Office (HDPO), located at the Y-12 National Security Complex in Oak Ridge, Tennessee. Disposition of the sodium bonded material will require separating the elemental sodium from the metallic uranium fuel. A sodium distillation process known as MEDE (Melt-Drain-Evaporate), will be used for the separation process. The casting scrap material needs to be sorted to remove any foreign material or fines that are not acceptable to the HDPO program. Once all elements have been cut and loaded into baskets, they are then loaded into an evaporation chamber as the first step in the MEDE process. The chamber will be sealed and the pressure reduced to approximately 200 mtorr. The chamber will then be heated as high as 650 C, causing the sodium to melt and then vaporize. The vapor phase sodium will be driven into an outlet line where it is condensed and drained into a receiver vessel. Once the evaporation operation is complete, the system is de-energized and returned to atmospheric pressure. This paper describes the MEDE process as well as a general overview of the furnace systems, as necessary, to complete the MEDE process.

Carl E. Baily; Karen A. Moore; Collin J. Knight; Peter B. Wells; Paul J. Petersen; Ali S. Siahpush; Matthew T. Weseman

2008-05-01T23:59:59.000Z

198

Solar test of an integrated sodium reflux heat-pipe receiver/reactor for thermochemical energy transport  

DOE Green Energy (OSTI)

In October 1987, a chemical reactor integrated into a sodium reflux heat-pipe receiver was tested in the solar furnace at the Weizmann Institute of Science, Rehovot, Israel. The reaction carried out was the carbon dioxide reforming of methane. This reaction is one of the leading candidates for thermochemical energy transport either within a distributed solar receiver system or over long distances. The Schaeffer Solar Furnace consists of a 96 square meter heliostat and a 7.3 meter diameter dish concentrator with a 65-degree rim angle and a 3.5 meter focal length. Measurements have shown a peak concentration ratio of over 10,000 and a total power of 15 kW at an insolation of 800 w/square meter. The receiver/reactor contains seven catalyst-filled tubes inside an evacuated metal box containing sodium. The front surface of this box serves as the solar absorber of the receiver. In operation, concentrated sunlight heats the 1/8-inch Inconel plate and vaporizes sodium from the wire-mesh wick attached to the back of it. The sodium vapor condenses on the reactor tubes, releases its latent heat, and returns by gravity to the wick. Test results and areas for future development are discussed.

Diver, R.B.; Fish, J.D.; Levitan, R.; Levy, M.; Rosin, H.; Richardson, J.T.

1988-01-01T23:59:59.000Z

199

Vapor scavenging by atmospheric aerosol particles  

Science Conference Proceedings (OSTI)

Particle growth due to vapor scavenging was studied using both experimental and computational techniques. Vapor scavenging by particles is an important physical process in the atmosphere because it can result in changes to particle properties (e.g., size, shape, composition, and activity) and, thus, influence atmospheric phenomena in which particles play a role, such as cloud formation and long range transport. The influence of organic vapor on the evolution of a particle mass size distribution was investigated using a modified version of MAEROS (a multicomponent aerosol dynamics code). The modeling study attempted to identify the sources of organic aerosol observed by Novakov and Penner (1993) in a field study in Puerto Rico. Experimentally, vapor scavenging and particle growth were investigated using two techniques. The influence of the presence of organic vapor on the particle`s hydroscopicity was investigated using an electrodynamic balance. The charge on a particle was investigated theoretically and experimentally. A prototype apparatus--the refractive index thermal diffusion chamber (RITDC)--was developed to study multiple particles in the same environment at the same time.

Andrews, E.

1996-05-01T23:59:59.000Z

200

Safety evaluation report related to the operation of Watts Bar Nuclear Plant, Units 1 and 2 (Docket Nos. 50-390 and 50-391). Supplement No. 15  

Science Conference Proceedings (OSTI)

This report supplements the Safety Evaluation Report (SER), NUREG-0847 (June 1982), Supplement No. 1 (September 1982), Supplement No. 2 (January 1984), Supplement No. 3 (January 1985), Supplement No. 4 (March 1985), Supplement No. 5 (November 1990), Supplement No. 6 (April 1991), Supplement No. 7 (September 1991), Supplement No. 8 (January 1992), Supplement No. 9 (June 1992), Supplement No. 10 (October 1992), Supplement No. 11 (April 1993), Supplement No. 12 (October 1993), Supplement No. 13 (April 1994), and Supplement No. 14 (December 1994) issued by the Office of Nuclear Reactor Regulation of the US Nuclear Regulatory Commission with respect to the application filed by the Tennessee Valley Authority, as applicant and owner, for licenses to operate the Watts Bar Nuclear Plant, Units 1 and 2 (Docket Nos. 50-390 and 50-391). The facility is located in Rhea County, Tennessee, near the Watts Bar Dam on the Tennessee River. This supplement provides recent information regarding resolution of some of the outstanding and confirmatory items, and proposed license conditions identified in the SER.

Tam, P.S.

1995-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

SPR-8 multi-mega watt space power system (MMW-SPS) concept description and concept refinement plan  

SciTech Connect

The SPR-8 MMW-SPS concept can satisfy both continuous and burst mode power requirements. At 10 MWe continuous mode power for 5 yr and 75 MWe burst mode power for 200 sec, the SPR-8 concept can power radar systems for detecting ballistic missile launchings and for discriminating between warheads and decoys. When enemy action is detected the SPR-8 MMW-SPS can power a rail gun, free electron laser, or particle beam and destroy the missile in the boost phase or warheads in space flight. The SPR-8 concept is based on the SPR-6 system (ref. 1) for providing continuous mode power. The system uses a fast UN-fueled, lithium-cooled reactor. Heat is transferred from the lithium coolant to potassium in a shell and tube heat exchanger-boiler. Potassium vapor is expanded through a turbine in a saturated Rankine cycle. After passing through the turbine the potassium is condensed in a compact heat exchanger by transferring heat to the radiator working fluid. An advanced radiator design is envisioned. Much work will be required in radiator technology to achieve low mass and plan form. For completeness of the SPR-8 system concept, a charged liquid droplet radiator is assumed but other types should be considered. Mechanical pumps are used for simplicity, but other types should be considered. A block diagram of the SPR-8 system is given.

Walter, C.E.

1985-04-15T23:59:59.000Z

202

Batteries with Orthorhombic Sodium Manganese Oxide Cathodes  

Berkeley National Laboratory researchers have discovered a low-cost, low-toxicity manganese oxide for rechargeable lithium and sodium batteries.

203

Electrolytic process to produce sodium hypochlorite using sodium ion conductive ceramic membranes  

SciTech Connect

An electrochemical process for the production of sodium hypochlorite is disclosed. The process may potentially be used to produce sodium hypochlorite from seawater or low purity un-softened or NaCl-based salt solutions. The process utilizes a sodium ion conductive ceramic membrane, such as membranes based on NASICON-type materials, in an electrolytic cell. In the process, water is reduced at a cathode to form hydroxyl ions and hydrogen gas. Chloride ions from a sodium chloride solution are oxidized in the anolyte compartment to produce chlorine gas which reacts with water to produce hypochlorous and hydrochloric acid. Sodium ions are transported from the anolyte compartment to the catholyte compartment across the sodium ion conductive ceramic membrane. Sodium hydroxide is transported from the catholyte compartment to the anolyte compartment to produce sodium hypochlorite within the anolyte compartment.

Balagopal, Shekar; Malhotra, Vinod; Pendleton, Justin; Reid, Kathy Jo

2012-09-18T23:59:59.000Z

204

atmospheric water vapor | OpenEI  

Open Energy Info (EERE)

atmospheric water vapor atmospheric water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for 2-axis tracking concentrating collectors for Mexico, Central America, and the Caribbean Islands. (Purpose): Provide information on the solar resource potential for the data domain. The insolation values represent the average solar energy available to a concentrating collector, such as a dish collector, which tracks the sun continuously. Source NREL Date Released July 31st, 2006 (8 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmospheric water vapor Carribean Islands Central America DNI GIS Mexico NREL GEF solar SWERA UNEP Data application/zip icon Download Shapefile (zip, 247.8 KiB) text/csv icon Download Data (csv, 370.6 KiB) Quality Metrics Level of Review Some Review

205

ARM - Field Campaign - Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsWater Vapor IOP govCampaignsWater Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Water Vapor IOP 1996.09.10 - 1996.09.30 Lead Scientist : Henry Revercomb For data sets, see below. Summary SCHEDULE This IOP will be conducted from September 10 - 30, 1996 (coincident with the Fall ARM-UAV IOP). Instruments that do not require supervision will be operated continuously during this period. Instruments that do require supervision are presently planned to be operated for 8-hour periods each day. Because it is necessary to cover as broad a range of environmental conditions as possible, the daily 8-hour period will be shifted across the diurnal cycle as deemed appropriate during the IOP (but will be maintained as a contiguous 8-hour block).

206

atmoshperic water vapor | OpenEI  

Open Energy Info (EERE)

atmoshperic water vapor atmoshperic water vapor Dataset Summary Description (Abstract): Monthly Average Solar Resource for flat-plate collectors tilted at latitude for China. Source NREL Date Released April 12th, 2005 (9 years ago) Date Updated October 30th, 2007 (7 years ago) Keywords atmoshperic water vapor China GEF GIS NREL solar SWERA TILT UNEP Data application/zip icon Download Shapefile (zip, 625.6 KiB) text/csv icon Download Data (csv, 704.1 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period 01/01/1985 - 12/31/1991 License License Open Data Commons Public Domain Dedication and Licence (PDDL) Comment Rate this dataset Usefulness of the metadata Average vote Your vote Usefulness of the dataset Average vote Your vote Ease of access

207

Thermal electric vapor trap arrangement and method  

DOE Patents (OSTI)

A technique for trapping vapor within a section of a tube is disclosed herein. This technique utilizes a conventional, readily providable thermal electric device having a hot side and a cold side and means for powering the device to accomplish this. The cold side of this device is positioned sufficiently close to a predetermined section of the tube and is made sufficiently cold so that any condensable vapor passing through the predetermined tube section is condensed and trapped, preferably within the predetermined tube section itself.

Alger, Terry (Tracy, CA)

1988-01-01T23:59:59.000Z

208

Adsorption of water vapor on reservoir rocks  

DOE Green Energy (OSTI)

Progress is reported on: adsorption of water vapor on reservoir rocks; theoretical investigation of adsorption; estimation of adsorption parameters from transient experiments; transient adsorption experiment -- salinity and noncondensible gas effects; the physics of injection of water into, transport and storage of fluids within, and production of vapor from geothermal reservoirs; injection optimization at the Geysers Geothermal Field; a model to test multiwell data interpretation for heterogeneous reservoirs; earth tide effects on downhole pressure measurements; and a finite-difference model for free surface gravity drainage well test analysis.

Not Available

1993-07-01T23:59:59.000Z

209

Method and Apparatus for Concentrating Vapors for Analysis  

DOE Patents (OSTI)

An apparatus and method are disclosed for pre-concentrating gaseous vapors for analysis. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable. Vapors sorbed and concentrated within the bed of the apparatus can be thermally desorbed achieving at least partial separation of vapor mixtures. The apparatus is suitable, e.g., for preconcentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than for direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications.

Grate, Jay W. (West Richland, WA); Baldwin, David L. (Kennewick, WA); Anheier, Jr., Norman C. (Richland, WA)

2008-10-07T23:59:59.000Z

210

Low Temperature Direct Growth of Graphene Films on Transparent Substrates by Chemical Vapor Deposition  

E-Print Network (OSTI)

and Few- Layer Graphene by Chemical Vapor Deposition",Liu, W. , et al. (2010). "Chemical vapor deposition of large5 1.3.3. Chemical Vapor

Antoine, Geoffrey Sandosh Jeffy

2013-01-01T23:59:59.000Z

211

Profiling Atmospheric Water Vapor by Microwave Radiometry  

Science Conference Proceedings (OSTI)

High-altitude microwave radiometric observations at frequencies near 92 and 183.3 GHz were used to study the potential of retrieving atmospheric water vapor profiles over both land and water. An algorithm based on an extended Kaiman-Bucy filter ...

J. R. Wang; J. L. King; T. T. Wilheit; G. Szejwach; L. H. Gesell; R. A. Nieman; D. S. Niver; B. M. Krupp; J. A. Gagliano

1983-05-01T23:59:59.000Z

212

Polynomial Fits to Saturation Vapor Pressure  

Science Conference Proceedings (OSTI)

The authors describe eighth- and sixth-order polynomial fits to Wexler's and Hyland-Wexler's saturation-vapor-pressure expressions. Fits are provided in both least-squares and relative-error norms. Error analysis is presented. The authors show ...

Piotr J. Flatau; Robert L. Walko; William R. Cotton

1992-12-01T23:59:59.000Z

213

Vaporization of synthetic fuels. Final report. [Thesis  

DOE Green Energy (OSTI)

The problem of transient droplet vaporization in a hot convective environment is examined. The main objective of the present study is to develop an algorithm for the droplet vaporization which is simple enough to be feasibly incorporated into a complete spray combustion analysis and yet will also account for the important physics such as liquid-phase internal circulation, unsteady droplet heating and axisymmetric gas-phase convection. A simplified liquid-phase model has been obtained based on the assumption of the existence of a Hill's spherical vortex inside the droplet together with some approximations made in the governing diffusion equation. The use of the simplified model in a spray situation has also been examined. It has been found that droplet heating and vaporization are essentially unsteady and droplet temperature is nonuniform for a significant portion of its lifetime. It has also been found that the droplet vaporization characteristic can be quite sensitive to the particular liquid-phase and gas-phase models. The results of the various models are compared with the existing experimental data. Due to large scattering in the experimental measurements, particularly the droplet diameter, no definite conclusion can be drawn based on the experimental data. Finally, certain research problems which are related to the present study are suggested for future studies.

Sirignano, W.A.; Yao, S.C.; Tong, A.Y.; Talley, D.

1983-01-01T23:59:59.000Z

214

Chemical vapor deposition of mullite coatings  

DOE Patents (OSTI)

This invention is directed to the creation of crystalline mullite coatings having uniform microstructure by chemical vapor deposition (CVD). The process comprises the steps of establishing a flow of reactants which will yield mullite in a CVD reactor, and depositing a crystalline coating from the reactant flow. The process will yield crystalline coatings which are dense and of uniform thickness.

Sarin, Vinod (Lexington, MA); Mulpuri, Rao (Boston, MA)

1998-01-01T23:59:59.000Z

215

A Water Vapor Index from Satellite Measurements  

Science Conference Proceedings (OSTI)

A method for deriving a water vapor index is presented. An important feature of the index is the fact that it does not rely on radiosondes. Thus, it is not influenced by problems associated with radiosondes and the extent to which the horizontal ...

Larry M. McMillin; David S. Crosby; Mitchell D. Goldberg

1995-07-01T23:59:59.000Z

216

In-Situ Method for Treating Residual Sodium  

DOE Patents (OSTI)

A unique process for deactivating residual sodium in Liquid Metal Fast Breeder Reactor (LMFBR) systems which uses humidified (but not saturated) carbon dioxide at ambient temperature and pressure to convert residual sodium into solid sodium bicarbonate.

Sherman, Steven R.; Henslee, S. Paul

2005-07-19T23:59:59.000Z

217

Microwave plasma chemical vapor deposition of nano-composite...  

NLE Websites -- All DOE Office Websites (Extended Search)

plasma chemical vapor deposition of nano-composite CPt thin-films Title Microwave plasma chemical vapor deposition of nano-composite CPt thin-films Publication Type Journal...

218

Microwave Plasma Chemical Vapor Depositon of Nano-Structured...  

NLE Websites -- All DOE Office Websites (Extended Search)

Plasma Chemical Vapor Depositon of Nano-Structured SnC Composite Thin-Film anodes for Li-ion Battteries Title Microwave Plasma Chemical Vapor Depositon of Nano-Structured SnC...

219

The Effect of vapor subcooling on film condensation of metals  

E-Print Network (OSTI)

This work presents an analysis of the interfacial "vapor-condensate" temperature distribution, which includes the effect of subcooling (supersaturation) in the vapor. Experimental data from previous investigators for ...

Fedorovich, Eugene D.

1968-01-01T23:59:59.000Z

220

Waste tank headspace gas and vapor characterization reference guide  

SciTech Connect

This document is to serve as a reference guide for gas and vapor sample results presented in tank characterization reports. It describes sampling equipment, devices, and protocols, and sample collection and analysis methods common to all vapor samples.

Huckaby, J.L.

1995-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Atmospheric Solar Heating Rate in the Water Vapor Bands  

Science Conference Proceedings (OSTI)

The total absorption of solar radiation by water vapor in clear atmosphere is parameterized as a simple function of the scaled water vapor amount. For applications to cloudy and hazy atmospheres, the flux-weighted k-distribution functions are ...

Ming-Dah Chou

1986-11-01T23:59:59.000Z

222

Estimating the Atmospheric Water Vapor Content from Sun Photometer Measurements  

Science Conference Proceedings (OSTI)

The differential absorption technique for estimating columnar water vapor values from the analysis of sunphotometric measurements with wide- and narrowband interferential filters centered near 0.94 ?m is discussed and adapted. Water vapor line ...

Artemio Plana-Fattori; Michel Legrand; Didier Tanr; Claude Devaux; Anne Vermeulen; Philippe Dubuisson

1998-08-01T23:59:59.000Z

223

Moisture Durability of Vapor Permeable Insulating Sheathing (Fact Sheet)  

SciTech Connect

In this project, Building America team Building Science Corporation researched some of the ramifications of using exterior, vapor permeable insulation on retrofit walls with vapor permeable cavity insulation. Retrofit strategies are a key factor in reducing exterior building stock consumption.

Not Available

2013-10-01T23:59:59.000Z

224

Improved Retrieval of Integrated Water Vapor from Water Vapor Radiometer Measurements Using Numerical Weather Prediction Models  

Science Conference Proceedings (OSTI)

Water vapor radiometer (WVR) retrieval algorithms require a priori information on atmospheric conditions along the line of sight of the radiometer in order to derive opacities from observed brightness temperatures. This paper's focus is the mean ...

Steven R. Chiswell; Steven Businger; Michael Bevis; Fredrick Solheim; Christian Rocken; Randolph Ware

1994-10-01T23:59:59.000Z

225

Effects of capillarity and vapor adsorption in the depletion of vapor-dominated geothermal reservoirs  

DOE Green Energy (OSTI)

Vapor-dominated geothermal reservoirs in natural (undisturbed) conditions contain water as both vapor and liquid phases. The most compelling evidence for the presence of distributed liquid water is the observation that vapor pressures in these systems are close to saturated vapor pressure for measured reservoir temperatures (White et al., 1971; Truesdell and White, 1973). Analysis of natural heat flow conditions provides additional, indirect evidence for the ubiquitous presence of liquid. From an analysis of the heat pipe process (vapor-liquid counterflow) Preuss (1985) inferred that effective vertical permeability to liquid phase in vapor-dominated reservoirs is approximately 10{sup 17} m{sup 2}, for a heat flux of 1 W/m{sup 2}. This value appears to be at the high end of matrix permeabilities of unfractured rocks at The Geysers, suggesting that at least the smaller fractures contribute to liquid permeability. For liquid to be mobile in fractures, the rock matrix must be essentially completely liquid-saturated, because otherwise liquid phase would be sucked from the fractures into the matrix by capillary force. Large water saturation in the matrix, well above the irreducible saturation of perhaps 30%, has been shown to be compatible with production of superheated steam (Pruess and Narasimhan, 1982). In response to fluid production the liquid phase will boil, with heat of vaporization supplied by the reservoir rocks. As reservoir temperatures decline reservoir pressures will decline also. For depletion of ''bulk'' liquid, the pressure would decline along the saturated vapor pressure curve, while for liquid held by capillary and adsorptive forces inside porous media, an additional decline will arise from ''vapor pressure lowering''. Capillary pressure and vapor adsorption effects, and associated vapor pressure lowering phenomena, have received considerable attention in the geothermal literature, and also in studies related to geologic disposal of heat generating nuclear wastes, and in the drying of porous materials. Geothermally oriented studies were presented by Chicoine et al. (1977), Hsieh and Ramey (1978, 1981), Herkelrath et al. (1983), and Nghiem and Ramey (1991). Nuclear waste-related work includes papers by Herkelrath and O'Neal (1985), Pollock (1986), Eaton and Bixler (1987), Pruess et al. (1990), Nitao (1990), and Doughty and E'ruess (1991). Applications to industrial drying of porous materials have been discussed by Hamiathy (1969) arid Whitaker (1977). This paper is primarily concerned with evaluating the impact of vapor pressure lowering (VPL) effects on the depletion behavior of vapor-dominated reservoirs. We have examined experimental data on vapor adsorption and capillary pressures in an effort to identify constitutive relationships that would be applicable to the tight matrix rocks of vapor-dominated systems. Numerical simulations have been performed to evaluate the impact of these effects on the depletion of vapor-dominated reservoirs.

Pruess, Karsten; O'Sullivan, Michael

1992-01-01T23:59:59.000Z

226

High-intensity-discharger 400-W sodium ballast. Phase II. Final report  

SciTech Connect

A research and development program directed toward design, test, and evaluation of an energy efficient High Intensity Discharge (HID) Solid-State 400 Watt Ballast lighting system was undertaken. Under Phase I of the project, the existing ballast was modified, performance characteristics were measured, efficiency was compared with a core/coil ballast including energy loss analysis. Six (6) prototype 400 W High Pressure Sodium Ballasts were built, for verification tests by an independent test facility prior to follow-on performance and life tests. This report covers Phase II of the project which was designed to make test data comparisons on results received from the independent test laboratory, determine methods to increase ballast efficiency, determine the importance of power factors, conduct bulb life tests, perform specification review, performance versus cost analysis, investigate the ballast to determine compliance with new FCC requirement, and determine a line transient specification in respect to solid state ballasting. In addition, Phase II required reliability testing, a manufacturing test plan, a marketing study for solid-state ballast, and the manufacture and delivery of fifteen (15) demonstration ballast units to LBL. These requirements are discussed.

Felper, G.

1981-10-01T23:59:59.000Z

227

SO/sub 2/ scrubbing: more work for sodium  

SciTech Connect

The effects that dry scrubbing of flue gases with sodium sorbents could have on supplies of naturally-occurring sodium compounds such as nahcolite and trona are discussed.

Not Available

1984-07-18T23:59:59.000Z

228

Modeling engine oil vaporization and transport of the oil vapor in the piston ring pack on internal combustion engines  

E-Print Network (OSTI)

A model was developed to study engine oil vaporization and oil vapor transport in the piston ring pack of internal combustion engines. With the assumption that the multi-grade oil can be modeled as a compound of several ...

Cho, Yeunwoo, 1973-

2004-01-01T23:59:59.000Z

229

Advanced Membrane Systems: Recovering Wasteful and Hazardous Fuel Vapors at the Gasoline Tank  

Energy.gov (U.S. Department of Energy (DOE))

Case study covering Compact Membrane Systems, Inc. and its membrane vapor processor that recovers fuel vapors from gasoline refueling.

230

Vapor-pressure lowering in geothermal systems  

SciTech Connect

The water vapor-pressure lowering phenomenon in porous media was investigated for a range of temperatures by measuring vapor pressure vs. mass of water adsorbed in consolidated sandstone cores and unconsolidated silica sands. Experimental results showed that the mass of water adsorbed on the rock surface is much more than the amount of pore steam. Results also revealed that the water adsorption is caused mainly by micropores in the porous medium. Measurement of the mass of methane and ethane adsorbed on dry rocks showed that the amount of adsorption is not great in comparison with the pore gas. It was found that adsorption data for water/sandstone core studies could be normalized with respect to temperature. Although this appears not to have been reported previously, it does agree in principle with findings for solid powders with micropores. Another interesting result was that reanalysis of previous studies of capillarity in sandstones indicates that experimental data probably were influenced mostly by adsorption.

Hsieh, C.H.; Ramey, H.J. Jr.

1983-02-01T23:59:59.000Z

231

Hydrocarbon pool and vapor fire data analysis  

SciTech Connect

The flame geometry and thermal radiation data from a series of large scale experiments involving liquefied petroleum gas (LPG) and gasoline spills on water were analyzed. The experiments were conducted at the Naval Weapons Center, China Lake, California. Two types of fires have been studied; namely, pool fires and vapor fires. The spill quantity varied from 4 m/sup 3/ to approximately 6 m/sup 3/. The LPG pool fire flame height to diameter ratio were between 3.5 and 4.5. The gasoline flame height was about 2. The flame emissive powers for LPG pool fires ranged from 78 kW/m/sup 2/ to 115 kW/m/sup 2/. The average surface emissive power for gasoline pool fire was 40 kW/m/sup 2/. The LPG vapor fire emissive power ranged from 159 to 269 kW/m/sup 2/. 63 figures, 13 tables.

Mudan, K.S.

1984-10-01T23:59:59.000Z

232

Copper vapor laser modular packaging assembly  

DOE Patents (OSTI)

A modularized packaging arrangement for one or more copper vapor lasers and associated equipment is disclosed herein. This arrangement includes a single housing which contains the laser or lasers and all their associated equipment except power, water and neon, and means for bringing power, water, and neon which are necessary to the operation of the lasers into the container for use by the laser or lasers and their associated equipment.

Alger, Terry W. (Tracy, CA); Ault, Earl R. (Dublin, CA); Moses, Edward I. (Castro Valley, CA)

1992-01-01T23:59:59.000Z

233

Copper vapor laser modular packaging assembly  

DOE Patents (OSTI)

A modularized packaging arrangement for one or more copper vapor lasers and associated equipment is disclosed herein. This arrangement includes a single housing which contains the laser or lasers and all their associated equipment except power, water and neon, and means for bringing power, water, and neon which are necessary to the operation of the lasers into the container for use by the laser or lasers and their associated equipment. 2 figs.

Alger, T.W.; Ault, E.R.; Moses, E.I.

1992-12-01T23:59:59.000Z

234

DuPont Chemical Vapor Technical Report  

Science Conference Proceedings (OSTI)

DuPont Safety Resources was tasked with reviewing the current chemical vapor control practices and providing preventive recommendations on best commercial techniques to control worker exposures. The increased focus of the tank closure project to meet the 2024 Tri-Party Agreement (TPA) milestones has surfaced concerns among some CH2MHill employees and other interested parties. CH2MHill is committed to providing a safe working environment for employees and desires to safely manage the tank farm operations using appropriate control measures. To address worker concerns, CH2MHill has chartered a ''Chemical Vapors Project'' to integrate the activities of multiple CH2MHill project teams, and solicit the expertise of external resources, including an independent Industrial Hygiene expert panel, a communications consultant, and DuPont Safety Resources. Over a three-month time period, DuPont worked with CH2MHill ESH&Q, Industrial Hygiene, Engineering, and the independent expert panel to perform the assessment. The process included overview presentations, formal interviews, informal discussions, documentation review, and literature review. DuPont Safety Resources concluded that it is highly unlikely that workers in the tank farms are exposed to chemicals above established standards. Additionally, the conventional and radiological chemistry is understood, the inherent chemical hazards are known, and the risk associated with chemical vapor exposure is properly managed. The assessment highlighted management's commitment to addressing chemical vapor hazards and controlling the associated risks. Additionally, we found the Industrial Hygiene staff to be technically competent and well motivated. The tank characterization data resides in a comprehensive database containing the tank chemical compositions and relevant airborne concentrations.

MOORE, T.L.

2003-10-03T23:59:59.000Z

235

OPERATIONAL TESTS OF EBWR VAPOR RECOVERY SYSTEM  

SciTech Connect

A description of the Experimental Boiling Water Reactor vapor-recovery system is given. The seal air operating pressures, temperatures, and moisture content were measured. Air flow through the seals was measured and seal wear was assessed. Assuming direct-cycle D/sub 2/ operation, the seals were evaluated relative to the amount of D/sub 2/ leakage that would be controlled (C.J.G.)

Gariboldi, R.J.; Jacobson, D.R.

1960-08-01T23:59:59.000Z

236

Transport properties of fission product vapors  

DOE Green Energy (OSTI)

Kinetic theory of gases is used to calculate the transport properties of fission product vapors in a steam and hydrogen environment. Provided in tabular form is diffusivity of steam and hydrogen, viscosity and thermal conductivity of the gaseous mixture, and diffusivity of cesium iodide, cesium hydroxide, diatomic tellurium and tellurium dioxide. These transport properties are required in determining the thermal-hydraulics of and fission product transport in light water reactors.

Im, K.H.; Ahluwalia, R.K.

1983-07-01T23:59:59.000Z

237

Apparatus and method for photochemical vapor deposition  

DOE Patents (OSTI)

A photochemical vapor deposition apparatus includes a reactor housing having a window in one wall above a reaction chamber in the housing. A transparent curtain divides the reaction chamber into a reaction zone and a flush zone. At least one substrate is mounted in the reaction zone in light communication with the window so that ultraviolet radiation may penetrate through the window into the reaction zone. The window is kept clear by a gas flowing through the flush zone.

Jackson, Scott C. (Wilmington, DE); Rocheleau, Richard E. (Wilmington, DE)

1987-03-31T23:59:59.000Z

238

Passive vapor transport solar heating systems  

DOE Green Energy (OSTI)

In the systems under consideration, refrigerant is evaporated in a solar collector and condensed in thermal storage for space or water heating located within the building at a level below that of the collector. Condensed liquid is lifted to an accumulator above the collector by the vapor pressure generated in the collector. Tests of two systems are described, and it is concluded that one of these systems offers distinct advantages.

Hedstrom, J.C.; Neeper, D.A.

1985-01-01T23:59:59.000Z

239

Radial power flattening in sodium fast reactors  

E-Print Network (OSTI)

In order to improve a new design for a uranium startup sodium cooled fast reactor which was proposed at MIT, this thesis evaluated radial power flattening by varying the fuel volume fraction at a fixed U-235 enrichment of ...

Krentz-Wee, Rebecca (Rebecca Elizabeth)

2012-01-01T23:59:59.000Z

240

Low-temperature Sodium-Beta Battery  

Rechargeable metallic sodium batteries have application in large-scale energy storage applications such as electric power generation and distribution, in motive applications such as electric vehicles, hybrids, and plug-in hybrids, and for aerospace ...

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

A molecular view of vapor deposited glasses  

SciTech Connect

Recently, novel organic glassy materials that exhibit remarkable stability have been prepared by vapor deposition. The thermophysical properties of these new ''stable'' glasses are equivalent to those that common glasses would exhibit after aging over periods lasting thousands of years. The origin of such enhanced stability has been elusive; in the absence of detailed models, past studies have discussed the formation of new polyamorphs or that of nanocrystals to explain the observed behavior. In this work, an atomistic molecular model of trehalose, a disaccharide of glucose, is used to examine the properties of vapor-deposited stable glasses. Consistent with experiment, the model predicts the formation of stable glasses having a higher density, a lower enthalpy, and higher onset temperatures than those of the corresponding ''ordinary'' glass formed by quenching the bulk liquid. Simulations reveal that newly formed layers of the growing vapor-deposited film exhibit greater mobility than the remainder of the material, thereby enabling a reorganization of the film as it is grown. They also reveal that ''stable'' glasses exhibit a distinct layered structure in the direction normal to the substrate that is responsible for their unusual properties.

Singh, Sadanand; Pablo, Juan J. de [Department of Chemical and Biological Engineering, University of Wisconsin, Madison Wisconsin 53706 (United States)

2011-05-21T23:59:59.000Z

242

Method of preparing silicon from sodium fluosilicate  

DOE Patents (OSTI)

A process for preparing high purity silicon metal from Na.sub.2 SiF.sub.6 (sodium fluosilicate). The sodium fluosilicate is heated to decomposition temperature to form NaF, which retains most of the impurities, and gaseous SiF.sub.4. The SiF.sub.4 is then reduced by the bomb reduction method using a reductant having a low packing density.

Schmidt, Frederick A. (Ames, IA); Rehbein, David (Ames, IA); Chiotti, Premo (Ames, IA)

1984-01-01T23:59:59.000Z

243

City of Lexington, Tennessee (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Tennessee (Utility Company) Tennessee (Utility Company) Jump to: navigation, search Name City of Lexington Place Tennessee Utility Id 10968 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Area Lighting Metal service(175 Watt Mercury Vapor) Lighting Area Lighting Service(100 Watt High Pressure Sodium) Lighting Area Lighting Service(400 Watt Metal Halide Shoe-Box Single) Lighting Area Lighting Service(400 Watt Metal Halide Shoe-Box Twin) Lighting Area Lighting service(100 Watt Decorative Acorn) Lighting

244

Village of Endicott, New York (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Village of Endicott Village of Endicott Place New York Utility Id 5875 Utility Location Yes Ownership M NERC Location NPCC NERC NPCC Yes ISO NY Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial, Professional and Small Power Installs Commercial Large Power and Light Installations Commercial Residential and Religious Customers Residential Security Lighting (100 Watt Glow) Lighting Security Lighting (175 Watt Mercury Vapor) Commercial Security Lighting (400 Watt Mercury Vapor) Commercial Security Lighting (400 Watt Sodium) Commercial

245

Jo-Carroll Energy Coop Inc | Open Energy Information  

Open Energy Info (EERE)

Jo-Carroll Energy Coop Inc Jo-Carroll Energy Coop Inc Jump to: navigation, search Name Jo-Carroll Energy Coop Inc Place Illinois Utility Id 9750 Utility Location Yes Ownership C NERC Location MRO NERC MRO Yes ISO MISO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Area Lighting Rate(100 Watts Sodium Vapor) Lighting Area Lighting Rate(175 Watts Mercury Vapor) Lighting Area Lighting Rate(250 Watts) Lighting Area Lighting Rate(400 Watts) Lighting Coincident Peak Service(OPTIONAL) Commercial Dual Fuel - A Commercial Electric Large General Service Commercial Electric Large General Service Time-of-day use Commercial

246

Central Texas Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Elec Coop, Inc Elec Coop, Inc Place Texas Utility Id 3282 Utility Location Yes Ownership C NERC Location TRE NERC ERCOT Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rate Schedule Commercial General Service Residential Irrigation and Large Pumping Rate Schedule Commercial Large Power Schedule Industrial Security Lights(100 Watt High Pressure Sodium) Lighting Security Lights(175 Watt Mercury Vapor ) Lighting Security Lights(250 Watt High Pressure Sodium) Lighting Security Lights(250 Watt Metal Halide (Special Application Only) Lighting

247

Development of models for the sodium version of the two-phase three-dimensional thermal hydraulics code THERMIT. [LMFBR  

SciTech Connect

Several different models and correlations were developed and incorporated in the sodium version of THERMIT, a thermal-hydraulics code written at MIT for the purpose of analyzing transients under LMFBR conditions. This includes: a mechanism for the inclusion of radial heat conduction in the sodium coolant as well as radial heat loss to the structure surrounding the test section. The fuel rod conduction scheme was modified to allow for more flexibility in modelling the gas plenum regions and fuel restructuring. The formulas for mass and momentum exchange between the liquid and vapor phases were improved. The single phase and two phase friction factors were replaced by correlations more appropriate to LMFBR assembly geometry.

Wilson, G.J.; Kazimi, M.S.

1980-05-01T23:59:59.000Z

248

Design, fabrication, and testing of a sodium evaporator for the STM4-120 kinematic Stirling engine  

DOE Green Energy (OSTI)

This report describes the development and testing of a compact heat-pipe heat exchanger kW(e) designed to transfer thermal energy from hot combustion gases to the heater tubes of a 25-kW(e) Stirling engine. In this system, sodium evaporates from a surface that is heated by a stream of hot gases. The liquid metal then condenses on the heater tubes of a Stirling engine, where energy is transferred to the engine`s helium working fluid. Tests on a prototype unit illustrated that a compact (8 cm {times} 13 cm {times} 16 cm) sodium evaporator can routinely transfer 15 kW(t) of energy at an operating vapor temperature of 760 C. Four of these prototype units were eventually used to power a 25-kW(e) Stirling engine system. Design details and test results from the prototype unit are presented in this report.

Rawlinson, K.S.; Adkins, D.R.

1995-05-01T23:59:59.000Z

249

Vapor port and groundwater sampling well  

DOE Patents (OSTI)

A method and apparatus have been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing. 10 figs.

Hubbell, J.M.; Wylie, A.H.

1996-01-09T23:59:59.000Z

250

Vapor port and groundwater sampling well  

DOE Patents (OSTI)

A method and apparatus has been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing.

Hubbell, Joel M. (Idaho Falls, ID); Wylie, Allan H. (Idaho Falls, ID)

1996-01-01T23:59:59.000Z

251

Copper vapor laser acoustic thermometry system  

DOE Patents (OSTI)

A copper vapor laser (CVL) acoustic thermometry system is disclosed. The invention couples an acoustic pulse a predetermined distance into a laser tube by means of a transducer and an alumina rod such that an echo pulse is returned along the alumina rod to the point of entry. The time differential between the point of entry of the acoustic pulse into the laser tube and the exit of the echo pulse is related to the temperature at the predetermined distance within the laser tube. This information is processed and can provide an accurate indication of the average temperature within the laser tube.

Galkowski, J.J.

1986-08-27T23:59:59.000Z

252

Photochemical studies of alkali halide vapors  

SciTech Connect

Thesis. An apparatus has been constructed for studying the photodissociation of alkali halides to produce excited alkali metal atoms. The key component is a low pressure H/sub 2/ arc continuum uv source. Radiation from this source, modulated by a chopping wheel and analyzed by a monochromator, enters a cell containing the alkali halide vapor. In the appropriate wavelength range, photodissociation occurs to produce the alkali atom in an excited /sup 2/p state, the flourescence from which is detected by a photomultiplier-lock-in amplifier combination. (auth)

Earl, B.L.

1973-08-01T23:59:59.000Z

253

Suppression of spurious mode oscillation in mega-watt 77-GHz gyrotron as a high quality probe beam source for the collective Thomson scattering in LHD  

Science Conference Proceedings (OSTI)

Collective Thomson scattering (CTS) diagnostic requires a strong probing beam to diagnose a bulk and fast ion distribution function in fusion plasmas. A mega-watt gyrotron for electron cyclotron resonance heating is used as a probing beam in the large helical device. Spurious mode oscillations are often observed during the turning on/off phase of the modulation. The frequency spectra of the 77-GHz gyrotron output power have been measured, and then one of the spurious modes, which interferes with the CTS receiver system, is identified as the TE{sub 17,6} mode at the frequency of 74.7 GHz. The mode competition calculation indicates that the increase of the magnetic field strength at the gyrotron resonator can avoid such a spurious mode and excite only the main TE{sub 18,6} mode. The spurious radiation at the 74.7 GHz is experimentally demonstrated to be suppressed in the stronger magnetic field than that optimized for the high-power operation.

Ogasawara, S. [Department of Energy Engineering and Science, Nagoya University, Nagoya 464-8463 (Japan); Kubo, S. [Department of Energy Engineering and Science, Nagoya University, Nagoya 464-8463 (Japan); National Institute for Fusion Science, 322-6 Oroshi-cho, Toki-shi 509-5292 (Japan); Nishiura, M.; Tanaka, K.; Shimozuma, T.; Yoshimura, Y.; Igami, H.; Takahashi, H.; Ito, S.; Takita, Y.; Kobayashi, S.; Mizuno, Y.; Okada, K. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki-shi 509-5292 (Japan); Tatematsu, Y.; Saito, T. [Research Center for Development of Far-Infrared Region, University of Fukui, Fukui 910-8507 (Japan); Minami, R.; Kariya, T.; Imai, T. [Plasma Research Center, University of Tsukuba, Tsukuba 305-8577 (Japan)

2012-10-15T23:59:59.000Z

254

ARM - Field Campaign - Fall 1997 Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Vapor IOP Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Fall 1997 Water Vapor IOP 1997.09.15 - 1997.10.05 Lead Scientist : Henry Revercomb For data sets, see below. Summary The Water Vapor IOP was conducted as a follow-up to a predecessor IOP on water vapor held in September 1996. This IOP relied heavily on both ground-based guest and CART instrumentation and in-situ aircraft and tethered sonde/kite measurements. Primary operational hours were from 6 p.m. Central until at least midnight, with aircraft support normally from about 9 p.m. until midnight when available. However, many daytime measurements were made to support this IOP. The first Water Vapor IOP primarily concentrated on the atmosphere's lowest

255

Analysis of the transient compressible vapor flow in heat pipe  

SciTech Connect

The transient compressible one-dimensional vapor flow dynamics in a heat pipe is modeled. The numerical results are obtained by using the implicit non-iterative Beam-Warming finite difference method. The model is tested for simulated heat pipe vapor flow and actual vapor flow in cylindrical heat pipes. A good comparison of the present transient results for the simulated heat pipe vapor flow with the previous results of a two-dimensional numerical model is achieved and the steady state results are in agreement with the existing experimental data. The transient behavior of the vapor flow under subsonic, sonic, and supersonic speeds and high mass flow rates are successfully predicted. The one-dimensional model also describes the vapor flow dynamics in cylindrical heat pipes at high temperatures.

Jang, J.H.; Faghri, A. [Wright State Univ., Dayton, OH (United States); Chang, W.S. [Wright Research and Development Center, Wright-Patterson, OH (United States)

1989-07-01T23:59:59.000Z

256

Method and apparatus for concentrating vapors for analysis  

DOE Patents (OSTI)

A pre-concentration device and a method are disclosed for concentrating gaseous vapors for analysis. Vapors sorbed and concentrated within the bed of the pre-concentration device are thermally desorbed, achieving at least partial separation of the vapor mixtures. The pre-concentration device is suitable, e.g., for pre-concentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable.

Grate, Jay W. (West Richland, WA); Baldwin, David L. (Kennewick, WA); Anheier, Jr., Norman C. (Richland, WA)

2012-06-05T23:59:59.000Z

257

PUD No 1 of Cowlitz County | Open Energy Information  

Open Energy Info (EERE)

Cowlitz County Cowlitz County Jump to: navigation, search Name PUD No 1 of Cowlitz County Place Washington Utility Id 4442 Utility Location Yes Ownership P NERC Location WECC NERC WECC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png DIRECT ACCESS DELIVERY CHARGE TRANSMISSION VOLTAGE DELIVERY SCHEDULE 62 Commercial GENERAL SERVICE SCHEDULE 5 Industrial PRIVATE STREET AND AREA LIGHTING SCHEDULE 10 Sodium Vapor 100 watts Lighting PRIVATE STREET AND AREA LIGHTING SCHEDULE 10 Sodium Vapor 200 watts Lighting PUBLIC STREET LIGHTING SERVICE SCHEDULE 40 - HPS 100 Watt Lighting

258

Interfacial instability induced by lateral vapor pressure fluctuation in bounded thin liquid-vapor layers  

E-Print Network (OSTI)

We study an instability of thin liquid-vapor layers bounded by rigid parallel walls from both below and above. In this system, the interfacial instability is induced by lateral vapor pressure fluctuation, which is in turn attributed to the effect of phase change: evaporation occurs at the hotter portion of the interface and condensation at the colder one. The high vapor pressure drives the liquid away and the low one pulls it up. A set of equations describing the temporal evolution of the interface of the liquid-vapor layers is derived. This model neglects the effect of mass loss or gain at the interface and guarantees the mass conservation of the liquid layer. The result of linear stability analysis of the model shows that the presence of the pressure dependence of the local saturation temperature suppresses the growth of long-wave disturbances. We find the stability criterion, which suggests that only slight temperature gradients are sufficient to overcome the stabilizing gravitational effect for a water an...

Kanatani, Kentaro

2008-01-01T23:59:59.000Z

259

Method for controlling corrosion in thermal vapor injection gases  

DOE Patents (OSTI)

An improvement in the method for producing high pressure thermal vapor streams from combustion gases for injection into subterranean oil producing formations to stimulate the production of viscous minerals is described. The improvement involves controlling corrosion in such thermal vapor gases by injecting water near the flame in the combustion zone and injecting ammonia into a vapor producing vessel to contact the combustion gases exiting the combustion chamber.

Sperry, John S. (Houston, TX); Krajicek, Richard W. (Houston, TX)

1981-01-01T23:59:59.000Z

260

Development of a model to predict flow oscillations in low-flow sodium boiling. [Loss-of-Piping Integrity accidents  

Science Conference Proceedings (OSTI)

Tests performed in a small scale water loop showed that voiding oscillations, similar to those observed in sodium, were present in water, as well. An analytical model, appropriate for either sodium or water, was developed and used to describe the water flow behavior. The experimental results indicate that water can be successfully employed as a sodium simulant, and further, that the condensation heat transfer coefficient varies significantly during the growth and collapse of vapor slugs during oscillations. It is this variation, combined with the temperature profile of the unheated zone above the heat source, which determines the oscillatory behavior of the system. The analytical program has produced a model which qualitatively does a good job in predicting the flow behavior in the wake experiment. The amplitude discrepancies are attributable to experimental uncertainties and model inadequacies. Several parameters (heat transfer coefficient, unheated zone temperature profile, mixing between hot and cold fluids during oscillations) are set by the user. Criteria for the comparison of water and sodium experiments have been developed.

Levin, A.E.; Griffith, P.

1980-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Mercury Vapor At Lassen Volcanic National Park Area (Varekamp...  

Open Energy Info (EERE)

Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon Mercury Vapor At Lassen Volcanic National Park Area (Varekamp & Buseck, 1983) Jump to:...

262

Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck,...  

Open Energy Info (EERE)

Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon Mercury Vapor At Mickey Hot Springs Area (Varekamp & Buseck, 1983) Jump to: navigation,...

263

Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck...  

Open Energy Info (EERE)

Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Breitenbush Hot Springs Area (Varekamp & Buseck, 1983) Exploration Activity...

264

Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983...  

Open Energy Info (EERE)

Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon Mercury Vapor At Vale Hot Springs Area (Varekamp & Buseck, 1983) Jump to: navigation, search...

265

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Haleakala Volcano Area (Thomas, 1986) Exploration Activity Details Location Haleakala Volcano Area Exploration Technique Mercury Vapor Activity Date Usefulness not indicated DOE-funding Unknown Notes The field survey program on the northwest rift zone consisted of soil mercury and radon emanometry surveys, groundwater temperature and chemistry studies, Schlumberger resistivity soundings and self-potential profiles. Geophysical and geochemical surveys along this rift (southwest) were limited by difficult field conditions and access limitations. The geophysical program consisted of one Schlumberger sounding, one

266

Measurements of Vapor Pressures and PVT Properties for n ...  

Science Conference Proceedings (OSTI)

Page 1. Measurements of Vapor Pressures and PVT Properties for n-Butane from 280 to 440 K at Pressures to 200 MPa ...

2006-07-20T23:59:59.000Z

267

Optimal Control of Vapor Extraction of Heavy Oil.  

E-Print Network (OSTI)

??Vapor extraction (Vapex) process is an emerging technology for viscous oil recovery that has gained much attention in the oil industry. However, the oil production (more)

Muhamad, Hameed

2012-01-01T23:59:59.000Z

268

ARM - Field Campaign - ARM-FIRE Water Vapor Experiment  

NLE Websites -- All DOE Office Websites (Extended Search)

Order Data Browell, Edward LASE Order Data Gutman, Seth GPS Order Data Richardson, Scott Chilled Mirror Order Data Sachse, G. Water Vapor Order Data Schmidlin, Francis CM Sondes...

269

Molecular restrictions for human eye irritation by chemical vapors  

E-Print Network (OSTI)

and reactive airborne chemicals. Pharmacol. Toxicol. 1998;WL. Chemesthesis: The Common Chemical Sense. In: Finger TE,MH. Quantification of chemical vapors in chemosensory

Cometto-Muniz, J. Enrique; Cain, William S.; Abraham, Michael H.

2005-01-01T23:59:59.000Z

270

Raman Lidar Measurements of Aerosols and Water Vapor During the...  

NLE Websites -- All DOE Office Websites (Extended Search)

Raman Lidar Measurements of Aerosols and Water Vapor During the May 2003 Aerosol IOP R. A. Ferrare National Aeronautics and Space Administration Langley Research Center Hampton,...

271

Cesium vapor cycle for an advanced LMFBR  

SciTech Connect

A review indicates that a cesium vapor topping cycle appears attractive for use in the intermediate fluid circuit of an advanced LMFBR designed for a reactor outlet temperature of 1250$sup 0$F or more and would have the following advantages: (1) it would increase the thermal efficiency by about 5 to 10 points (from approximately 40 percent to approximately 45 to 50 percent) thus reducing the amount of waste heat rejected to the environment by 15 to 30 percent. (2) the higher thermal efficiency should reduce the overall capital cost of the reactor plant in dollars per kilowatt. (3) the cesium can be distilled out of the intermediate fluid circuit to leave it bone-dry, thus greatly reducing the time and cost of maintenance work (particularly for the steam generator). (4) the large volume and low pressure of the cesium vapor region in the cesium condenser-steam generator greatly reduces the magnitude of pressure fluctuations that might occur in the event of a leak in a steam generator tube, and the characteristics inherent in a condenser make it easy to design for rapid concentration of any noncondensibles that may form as a consequence of a steam leak into the cesium region so that a steam leak can be detected easily in the very early stages of its development. (auth)

Fraas, A.P.

1975-01-01T23:59:59.000Z

272

Reactions of atmospheric vapors with lunar soil  

SciTech Connect

Detailed experimental data have been acquired for the hydration of the surfaces of lunar fines. Inert vapor adsorption has been employed to measure the surface properties (surface energy, surface area, porosity, etc.) and changes wrought in the hydration-dehydration processes. Plausible mechanisms have been considered and the predominant process involves hydration of the metamict metallosilicate surfaces to form a hydrated laminar structure akin to terrestrial clays. Additional credence for this interpretation is obtained by comparison to existing geochemical literature concerning terrestrial weathering of primary metallosilicates. The surface properties of the hydrated lunar fines are compared favorably to those of terrestrial clay minerals. In addition, experimental results are given to show that fresh disordered surfaces of volcanic sand react with water vapor in a manner virtually identical to the majority of the lunar fines. The results show that ion track etching and/or grain boundary attack are minor contributions in the weathering of lunar fines in the realm of our microgravimetric experimental conditions. 14 references. (auth)

Fuller, E.L. Jr.; Agron, P.A.

1976-03-01T23:59:59.000Z

273

Ethanol production by vapor compression distillation  

DOE Green Energy (OSTI)

The goal of this project is to develop and demonstrate a one gallon per hour vapor compression distillation unit for fuel ethanol production that can be profitably manufactured and economically operated by individual family units. Vapor compression distillation is already an industrially accepted process and this project's goal is to demonstrate that it can be done economically on a small scale. Theoretically, the process is independent of absolute pressure. It is only necessary that the condenser be at higher pressure than the evaporator. By reducing the entire process to a pressure of approximately 0.1 atmosphere, the evaporation and condensation can occur at near ambient temperature. Even though this approach requires a vacuum pump, and thus will not represent the final cost effective design, it does not require preheaters, high temperature materials, or as much insulation as if it were to operate a near ambient pressure. Therefore, the operation of the ambient temperature unit constitutes the first phase of this project. Presently, the ambient temperature unit is fully assembled and has begun testing. So far it has successfully separated ethanol from a nine to one diluted input solution. However the production rate has been very low.

Ellis, G.S.

1981-01-01T23:59:59.000Z

274

Method of making a sodium sulfur battery  

SciTech Connect

A method of making a portion of a sodium sulfur battery is disclosed. The battery portion made is a portion of the container which defines the volume for the cathodic reactant materials which are sulfur and sodium polysulfide materials. The container portion is defined by an outer metal casing with a graphite liner contained therein, the graphite liner having a coating on its internal diameter for sealing off the porosity thereof. The steel outer container and graphite pipe are united by a method which insures that at the operating temperature of the battery, relatively low electrical resistance exists between the two materials because they are in intimate contact with one another.

Elkins, Perry E. (Santa Ana, CA)

1981-01-01T23:59:59.000Z

275

A High Temperature Electrochemical Energy Storage System Based on Sodium Beta-Alumina Solid Electrolyte (Base)  

DOE Green Energy (OSTI)

This report summarizes the work done during the period September 1, 2005 and March 31, 2008. Work was conducted in the following areas: (1) Fabrication of sodium beta{double_prime} alumina solid electrolyte (BASE) using a vapor phase process. (2) Mechanistic studies on the conversion of {alpha}-alumina + zirconia into beta{double_prime}-alumina + zirconia by the vapor phase process. (3) Characterization of BASE by X-ray diffraction, SEM, and conductivity measurements. (4) Design, construction and electrochemical testing of a symmetric cell containing BASE as the electrolyte and NaCl + ZnCl{sub 2} as the electrodes. (5) Design, construction, and electrochemical evaluation of Na/BASE/ZnCl{sub 2} electrochemical cells. (6) Stability studies in ZnCl{sub 2}, SnCl{sub 2}, and SnI{sub 4} (7) Design, assembly and testing of planar stacks. (8) Investigation of the effect of porous surface layers on BASE on cell resistance. The conventional process for the fabrication of sodium ion conducting beta{double_prime}-alumina involves calcination of {alpha}-alumina + Na{sub 2}CO{sub 3} + LiNO{sub 3} at 1250 C, followed by sintering powder compacts in sealed containers (platinum or MgO) at {approx}1600 C. The novel vapor phase process involves first sintering a mixture of {alpha}-alumina + yttria-stabilized zirconia (YSZ) into a dense ceramic followed by exposure to soda vapor at {approx}1450 C to convert {alpha}-alumina into beta{double_prime}-alumina. The vapor phase process leads to a high strength BASE, which is also resistant to moisture attack, unlike BASE made by the conventional process. The PI is the lead inventor of the process. Discs and tubes of BASE were fabricated in the present work. In the conventional process, sintering of BASE is accomplished by a transient liquid phase mechanism wherein the liquid phase contains NaAlO{sub 2}. Some NaAlO{sub 2} continues to remain at grain boundaries; and is the root cause of its water sensitivity. In the vapor phase process, NaAlO{sub 2} is never formed. Conversion occurs by a coupled transport of Na{sup +} through BASE formed and of O{sup 2-} through YSZ to the reaction front. Transport to the reaction front is described in terms of a chemical diffusion coefficient of Na{sub 2}O. The conversion kinetics as a function of microstructure is under investigation. The mechanism of conversion is described in this report. A number of discs and tubes of BASE have been fabricated by the vapor phase process. The material was investigated by X-ray diffraction (XRD), optical microscopy and scanning electron microscopy (SEM), before and after conversion. Conductivity (which is almost exclusively due to sodium ion transport at the temperatures of interest) was measured. Conductivity was measured using sodium-sodium tests as well as by impedance spectroscopy. Various types of both planar and tubular electrochemical cells were assembled and tested. In some cases the objective was to determine if there was any interaction between the salt and BASE. The interaction of interest was mainly ion exchange (possible replacement of sodium ion by the salt cation). It was noted that Zn{sup 2+} did not replace Na+ over the conditions of interest. For this reason much of the work was conducted with ZnCl{sub 2} as the cathode salt. In the case of Sn-based, Sn{sup 2+} did ion exchange, but Sn{sup 4+} did not. This suggests that Sn{sup 4+} salts are viable candidates. These results and implications are discussed in the report. Cells made with Na as the anode and ZnCl{sub 2} as the cathode were successfully charged/discharged numerous times. The key advantages of the batteries under investigation here over the Na-S batteries are: (1) Steel wool can be used in the cathode compartment unlike Na-S batteries which require expensive graphite. (2) Planar cells can be constructed in addition to tubular, allowing for greater design flexibility and integration with other devices such as planar SOFC. (3) Comparable or higher open circuit voltage (OCV) than the Na-S battery. (4) Wider operating temperature range and higher temper

Anil Virkar

2008-03-31T23:59:59.000Z

276

City of Auburn, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Auburn, Indiana (Utility Company) Auburn, Indiana (Utility Company) Jump to: navigation, search Name City of Auburn Place Auburn, Indiana Utility Id 994 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] SGIC[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. City of Auburn, IN Smart Grid Project was awarded $2,075,080 Recovery Act Funding with a total project value of $4,150,160. Utility Rate Schedules Grid-background.png Private Outdoor Lighting- 100 watt sodium vapor lamp Lighting Private Outdoor Lighting- 175 watt mercury vapor lamp Lighting Private Outdoor Lighting- 250 watt mercury vapor lamp Lighting

277

Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates  

NLE Websites -- All DOE Office Websites (Extended Search)

Integration of Global Positioning System and Scanning Integration of Global Positioning System and Scanning Water Vapor Radiometers for Precipitable Water Vapor and Cloud Liquid Path Estimates V. Mattioli and P. Basili Department of Electronic and Information Engineering University of Perugia Perugia, Italy E. R. Westwater Cooperative Institute for Research in Environmental Sciences University of Colorado National Oceanic and Atmospheric Administration Environmental Technology Laboratory Boulder, Colorado Introduction In recent years the Global Positioning System (GPS) has proved to be a reliable instrument for measuring precipitable water vapor (PWV) (Bevis et al. 1992), offering an independent source of information on water vapor when compared with microwave radiometers (MWRs), and/or radiosonde

278

Vapor and gas sampling of Single-Shell Tank 241-A-101 using the Vapor Sampling System  

Science Conference Proceedings (OSTI)

This document presents sampling data resulting from the June 8, 1995, sampling of SST 241-A-101 using the Vapor Sampling System.

Caprio, G.S.

1995-11-01T23:59:59.000Z

279

Vapor and gas sampling of single-shell tank 241-SX-106 using the vapor sampling system  

SciTech Connect

This document presents sampling data resulting from the March 24, 1995, sampling of SST 241-SX-106 using the vapor sampling system.

Caprio, G.S.

1995-09-20T23:59:59.000Z

280

eclipsePower : Watt daylightPower : Watt  

E-Print Network (OSTI)

Highly Scalable Distributed Dataflow Analysis Joseph L. Greathouse, Chelsea LeBlanc, Todd Austin- visor's page fault handler then checks the page number against a list of pages that contain shadowed timekeeping code in the timer interrupt handler and the scheduler code of dom0 and the hypervisor. We

de Weck, Olivier L.

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Heat-source specification 500 watt(e) RTG  

DOE Green Energy (OSTI)

This specification establishes the requirements for a /sup 90/SrF/sub 2/ heat source and its fuel capsule for application in a 500 W(e) thermoelectric generator. The specification covers: fuel composition and quantity; the Hastelloy S fuel capsule material and fabrication; and the quality assurance requirements for the assembled heat source. (LCL)

Not Available

1983-02-01T23:59:59.000Z

282

INHIBITION OF WASHED SLUDGE WITH SODIUM NITRITE  

SciTech Connect

This report describes the results of electrochemical tests used to determine the relationship between the concentration of the aggressive anions in washed sludge and the minimum effective inhibitor concentration. Sodium nitrate was added as the inhibitor because of its compatibility with the DWPF process. A minimum of 0.05M nitrite is required to inhibit the washed sludge simulant solution used in this study. When the worst case compositions and safety margins are considered, it is expected that a minimum operating limit of nearly 0.1M nitrite will be specified. The validity of this limit is dependent on the accuracy of the concentrations and solubility splits previously reported. Sodium nitrite additions to obtain 0.1M nitrite concentrations in washed sludge will necessitate the additional washing of washed precipitate in order to decrease its sodium nitrite inhibitor requirements sufficiently to remain below the sodium limits in the feed to the DWPF. Nitrite will be the controlling anion in "fresh" washed sludge unless the soluble chloride concentration is about ten times higher than predicted by the solubility splits. Inhibition of "aged" washed sludge will not be a problem unless significant chloride dissolution occurs during storage. It will be very important tomonitor the composition of washed sludge during processing and storage.

Congdon, J.; Lozier, J.

2012-09-25T23:59:59.000Z

283

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR  

E-Print Network (OSTI)

RESONANT FARADAY ROTATION IN A HOT LITHIUM VAPOR By SCOTT RUSSELL WAITUKAITIS A Thesis Submitted: #12;Abstract I describe a study of Faraday rotation in a hot lithium vapor. I begin by dis- cussing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.3 The Lithium Oven and Solenoid . . . . . . . . . . . . . . . . . 7 3 Theoretical Framework

Cronin, Alex D.

284

New Regenerative Cycle for Vapor Compression Refrigeration  

Office of Scientific and Technical Information (OSTI)

SCIENTIFIC REPORT SCIENTIFIC REPORT Title Page Project Title: New Regenerative Cycle for Vapor Compression Refrigeration DOE Award Number: DE-FG36-04GO14327 Document Title: Final Scientific Report Period Covered by Report: September 30, 2004 to September 30, 2005 Name and Address of Recipient Organization: Magnetic Development, Inc., 68 Winterhill Road, Madison, CT 06443, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Contact Information: Mark J. Bergander, Ph.D., P.E., Principal Investigator, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Project Objective (as stated in the proposal): The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient

285

FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS  

Office of Scientific and Technical Information (OSTI)

Bulletin 627 Bulletin 627 BUREAU o b MINES FLAMMABILITY CHARACTERISTICS OF COMBUSTIBLE GASES AND VAPORS By Michael G. Zabetakis DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency Thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement,

286

Gas transport model for chemical vapor infiltration  

Science Conference Proceedings (OSTI)

A node-bond percolation model is presented for the gas permeability and pore surface area of the coarse porosity in woven fiber structures during densification by chemical vapor infiltration (CVI). Model parameters include the number of nodes per unit volume and their spatial distribution, and the node and bond radii and their variability. These parameters relate directly to structural features of the weave. Some uncertainty exists in the proper partition of the porosity between ``node`` and ``bond`` and between intra-tow and inter-tow, although the total is constrained by the known fiber loading in the structure. Applied to cloth layup preforms the model gives good agreement with the limited number of available measurements.

Starr, T.L. [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0245 (United States)

1995-09-01T23:59:59.000Z

287

How solvent vapors can improve steam floods  

Science Conference Proceedings (OSTI)

Thermal recovery methods depend for their success on the viscosity reduction of heavy crude oils at high temperatures. The viscosity of a heavy oil can also be reduced if it is diluted with a low-viscosity solvent, such as one of the lighter hydrocarbons. It is not surprising that there has been considerable interest in combining the two methods. The process of injecting vaporized solvent with the steam for a gravity drainage type recovery is described here along with a description of the particular phase behavior of steam/solvent mixtures which is beneficial to the process. And computer simulations which compare steam-only and steam/solvent floods under Athabasca-type conditions are overviewed.

Vogel, J. [Vogel, (Jack), Seabrook, TX (United States)

1996-11-01T23:59:59.000Z

288

The electrical conductivity of sodium polysulfide melts  

DOE Green Energy (OSTI)

The sodium polysulfide melt has been described by a macroscopic model. This model considers the melt to be composed of sodium cations, monosulfide anions, and neutral sulfur solvent. The transport equations of concentrated-solution theory are used to derived the governing equations for this binaryelectrolyte melt model. These equations relate measurable transport properties to fundamental transport parameters. The focus of this research is to measure the electrical conductivity of sodium polysulfide melts and calculate one of fundamental transport parameters from the experimental data. The conductance cells used in the conductivity measurements are axisymmetric cylindrical cells with a microelectrode. The electrode effects, including double-layer capacity, charge transfer resistance, and concentration overpotential, were minimized by the use of the alternating current at an adequately high frequency. The high cell constants of the conductance cells not only enhanced the experimental accuracy but also made the electrode effects negligible. The electrical conductivities of sodium polysulfide Na{sub 2}S{sub 4} and Na{sub 2}S{sub 5} were measured as a function of temperature (range: 300 to 360{degree}C). Variations between experiments were only up to 2%. The values of the Arrhenius activation energy derived from the experimental data are about 33 kJ/mol. The fundamental transport parameter which quantifies the interaction within sodium cations and monosulfide anions are of interest and expected to be positive. Values of it were calculated from the experimental conductivity data and most of them are positive. Some negative values were obtained probably due to the experimental errors of transference number, diffusion coefficient, density or conductivity data.

Meihui Wang

1992-06-01T23:59:59.000Z

289

Viscosity and density tables of sodium chloride solutions  

DOE Green Energy (OSTI)

A file is presented containing tabulated data extracted from the scientific literature on the density and viscosity of aqueous sodium chloride solutions. Also included is a bibliography of the properties of aqueous sodium chloride solutions. (MHR)

Fair, J.A.; Ozbek, H. (comps.) [comps.

1977-04-01T23:59:59.000Z

290

NIST Pico-Watt ACR  

Science Conference Proceedings (OSTI)

... ACR the equivalence between the electrical and optical ... ACR cavity has significantly lower heat capacity ... Low frequency temperature noise of a TES ...

2013-04-10T23:59:59.000Z

291

Hybrid Vapor Compression Adsorption System: Thermal Storage Using Hybrid Vapor Compression Adsorption System  

SciTech Connect

HEATS Project: UTRC is developing a new climate-control system for EVs that uses a hybrid vapor compression adsorption system with thermal energy storage. The targeted, closed system will use energy during the battery-charging step to recharge the thermal storage, and it will use minimal power to provide cooling or heating to the cabin during a drive cycle. The team will use a unique approach of absorbing a refrigerant on a metal salt, which will create a lightweight, high-energy-density refrigerant. This unique working pair can operate indefinitely as a traditional vapor compression heat pump using electrical energy, if desired. The project will deliver a hot-and-cold battery that provides comfort to the passengers using minimal power, substantially extending the driving range of EVs.

None

2012-01-04T23:59:59.000Z

292

Structure and Properties of Piezoelectric Sodium Bismuth Titanate ...  

Science Conference Proceedings (OSTI)

Presentation Title, Structure and Properties of Piezoelectric Sodium Bismuth Titanate ... Nanostructures and Their Potential for Mechanical Energy Scavenging.

293

Worker Protection from Chemical Vapors: Hanford Tank Farms  

Science Conference Proceedings (OSTI)

Chemical vapor emissions from underground hazardous waste storage tanks on the Hanford site in eastern Washington State are a potential concern because workers enter the tank farms on a regular basis for waste retrievals, equipment maintenance, and surveillance. Tank farm contractors are in the process of retrieving all remaining waste from aging single-shell tanks, some of which date to World War II, and transferring it to newer double-shell tanks. During the waste retrieval process, tank farm workers are potentially exposed to fugitive chemical vapors that can escape from tank head-spaces and other emission points. The tanks are known to hold more than 1,500 different species of chemicals, in addition to radionuclides. Exposure assessments have fully characterized the hazards from chemical vapors in half of the tank farms. Extensive sampling and analysis has been done to characterize the chemical properties of hazardous waste and to evaluate potential health hazards of vapors at the ground surface, where workers perform maintenance and waste transfer activities. Worker concerns, risk communication, and exposure assessment are discussed, including evaluation of the potential hazards of complex mixtures of chemical vapors. Concentrations of vapors above occupational exposure limits (OEL) were detected only at exhaust stacks and passive breather filter outlets. Beyond five feet from the sources, vapors disperse rapidly. No vapors have been measured above 50% of their OELs more than five feet from the source. Vapor controls are focused on limited hazard zones around sources. Further evaluations of vapors include analysis of routes of exposure and thorough analysis of nuisance odors. (authors)

Anderson, T.J. [CH2M HILL Hanford Group, Inc. / Environmental Health, Richland, WA (United States)

2007-07-01T23:59:59.000Z

294

The Effects of Water Vapor on the Oxidation of Nickel-Base ...  

Science Conference Proceedings (OSTI)

water vapor are compared at temperatures from 700C to 1100C. It is shown that water vapor affects the oxidation of such alloys in different ways. Water vapor...

295

Water Vapor Flux Measurements from Ground-Based Vertically Pointed Water Vapor Differential Absorption and Doppler Lidars  

Science Conference Proceedings (OSTI)

For the first time, two lidar systems were used to measure the vertical water vapor flux in a convective boundary layer by means of eddy correlation. This was achieved by combining a water vapor differential absorption lidar and a heterodyne wind ...

Andreas Giez; Gerhard Ehret; Ronald L. Schwiesow; Kenneth J. Davis; Donald H. Lenschow

1999-02-01T23:59:59.000Z

296

Sodium and sulfur release and recapture during black liquor burning  

DOE Green Energy (OSTI)

The objective of this study was to provide data on sulfur and sodium volatilization during black liquor burning, and on SO2 capture by solid sodium carbonate and sodium chloride. This data was interpreted and modeled into rate equations suitable for use in computational models for recovery boilers.

Frederick, W.J.; Iisa, K.; Wag, K.; Reis, V.V.; Boonsongsup, L.; Forssen, M.; Hupa, M.

1995-08-01T23:59:59.000Z

297

Corrosion performance of advanced structural materials in sodium.  

SciTech Connect

This report gives a description of the activities in design, fabrication, construction, and assembling of a pumped sodium loop for the sodium compatibility studies on advanced structural materials. The work is the Argonne National Laboratory (ANL) portion of the effort on the work project entitled, 'Sodium Compatibility of Advanced Fast Reactor Materials,' and is a part of Advanced Materials Development within the Reactor Campaign. The objective of this project is to develop information on sodium corrosion compatibility of advanced materials being considered for sodium reactor applications. This report gives the status of the sodium pumped loop at Argonne National Laboratory, the specimen details, and the technical approach to evaluate the sodium compatibility of advanced structural alloys. This report is a deliverable from ANL in FY2010 (M2GAN10SF050302) under the work package G-AN10SF0503 'Sodium Compatibility of Advanced Fast Reactor Materials.' Two reports were issued in 2009 (Natesan and Meimei Li 2009, Natesan et al. 2009) which examined the thermodynamic and kinetic factors involved in the purity of liquid sodium coolant for sodium reactor applications as well as the design specifications for the ANL pumped loop for testing advanced structural materials. Available information was presented on solubility of several metallic and nonmetallic elements along with a discussion of the possible mechanisms for the accumulation of impurities in sodium. That report concluded that the solubility of many metals in sodium is low (<1 part per million) in the temperature range of interest in sodium reactors and such trace amounts would not impact the mechanical integrity of structural materials and components. The earlier report also analyzed the solubility and transport mechanisms of nonmetallic elements such as oxygen, nitrogen, carbon, and hydrogen in laboratory sodium loops and in reactor systems such as Experimental Breeder Reactor-II, Fast Flux Test Facility, and Clinch River Breeder Reactor. Among the nonmetallic elements discussed, oxygen is deemed controllable and its concentration in sodium can be maintained in sodium for long reactor life by using cold-trap method. It was concluded that among the cold-trap and getter-trap methods, the use of cold trap is sufficient to achieve oxygen concentration of the order of 1 part per million. Under these oxygen conditions in sodium, the corrosion performance of structural materials such as austenitic stainless steels and ferritic steels will be acceptable at a maximum core outlet sodium temperature of {approx}550 C. In the current sodium compatibility studies, the oxygen concentration in sodium will be controlled and maintained at {approx}1 ppm by controlling the cold trap temperature. The oxygen concentration in sodium in the forced convection sodium loop will be controlled and monitored by maintaining the cold trap temperature in the range of 120-150 C, which would result in oxygen concentration in the range of 1-2 ppm. Uniaxial tensile specimens are being exposed to flowing sodium and will be retrieved and analyzed for corrosion and post-exposure tensile properties. Advanced materials for sodium exposure include austenitic alloy HT-UPS and ferritic-martensitic steels modified 9Cr-1Mo and NF616. Among the nonmetallic elements in sodium, carbon was assessed to have the most influence on structural materials since carbon, as an impurity, is not amenable to control and maintenance by any of the simple purification methods. The dynamic equilibrium value for carbon in sodium systems is dependent on several factors, details of which were discussed in the earlier report. The current sodium compatibility studies will examine the role of carbon concentration in sodium on the carburization-decarburization of advanced structural materials at temperatures up to 650 C. Carbon will be added to the sodium by exposure of carbon-filled iron tubes, which over time will enable carbon to diffuse through iron and dissolve into sodium. The method enables addition of dissolved carbon (without carb

Natesan, K.; Momozaki, Y.; Li, M.; Rink, D.L. (Nuclear Engineering Division)

2012-05-16T23:59:59.000Z

298

Mercury Vapor At Silver Peak Area (Henkle, Et Al., 2005) | Open...  

Open Energy Info (EERE)

Mercury Vapor At Silver Peak Area (Henkle, Et Al., 2005) Exploration Activity Details Location Silver Peak Area Exploration Technique Mercury Vapor Activity Date Usefulness useful...

299

EA-0881: Tank 241-c-103 Organic Vapor and Liquid Characterization...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

881: Tank 241-c-103 Organic Vapor and Liquid Characterization and Supporting Activities, Hanford Site, Richland, Washington EA-0881: Tank 241-c-103 Organic Vapor and Liquid...

300

Does EIA report water vapor emissions data? - FAQ - U.S. Energy ...  

U.S. Energy Information Administration (EIA)

Does EIA report water vapor emissions data? No. Water vapor is the most abundant greenhouse gas, but most scientists believe that human activity has a very small ...

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

CAST STONE FORMULATION AT HIGHER SODIUM CONCENTRATIONS  

SciTech Connect

A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, including production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leach indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the limited

Fox, K.; Edwards, T.; Roberts, K.

2013-10-02T23:59:59.000Z

302

CAST STONE FORMULATION AT HIGHER SODIUM CONCENTRATIONS  

SciTech Connect

A low temperature waste form known as Cast Stone is being considered to provide supplemental Low Activity Waste (LAW) immobilization capacity for the Hanford site. Formulation of Cast Stone at high sodium concentrations is of interest since a significant reduction in the necessary volume of Cast Stone and subsequent disposal costs could be achieved if an acceptable waste form can be produced with a high sodium molarity salt solution combined with a high water to premix (or dry blend) ratio. The objectives of this study were to evaluate the factors involved with increasing the sodium concentration in Cast Stone, including production and performance properties and the retention and release of specific components of interest. Three factors were identified for the experimental matrix: the concentration of sodium in the simulated salt solution, the water to premix ratio, and the blast furnace slag portion of the premix. The salt solution simulants used in this study were formulated to represent the overall average waste composition. The cement, blast furnace slag, and fly ash were sourced from a supplier in the Hanford area in order to be representative. The test mixes were prepared in the laboratory and fresh properties were measured. Fresh density increased with increasing sodium molarity and with decreasing water to premix ratio, as expected given the individual densities of these components. Rheology measurements showed that all of the test mixes produced very fluid slurries. The fresh density and rheology data are of potential value in designing a future Cast Stone production facility. Standing water and density gradient testing showed that settling is not of particular concern for the high sodium compositions studied. Heat of hydration measurements may provide some insight into the reactions that occur within the test mixes, which may in turn be related to the properties and performance of the waste form. These measurements showed that increased sodium concentration in the salt solution reduced the time to peak heat flow, and reducing the amount of slag in the premix increased the time to peak heat flow. These observations may help to describe some of the cured properties of the samples, in particular the differences in compressive strength observed after 28 and 90 days of curing. Samples were cured for at least 28 days at ambient temperature in the laboratory prior to cured properties analyses. The low activity waste form for disposal at the Hanford Site is required to have a compressive strength of at least 500 psi. After 28 days of curing, several of the test mixes had mean compressive strengths that were below the 500 psi requirement. Higher sodium concentrations and higher water to premix ratios led to reduced compressive strength. Higher fly ash concentrations decreased the compressive strength after 28 days of curing. This may be explained in that the cementitious phases matured more quickly in the mixes with higher concentrations of slag, as evidenced by the data for the time to peak heat generation. All of the test mixes exhibited higher mean compressive strengths after 90 days of curing, with only one composition having a mean compressive strength of less than 500 psi. Leach indices were determined for the test mixes for contaminants of interest. The leaching performance of the mixes evaluated in this study was not particularly sensitive to the factors used in the experimental design. This may be beneficial in demonstrating that the performance of the waste form is robust with respect to changes in the mix composition. The results of this study demonstrate the potential to achieve significantly higher waste loadings in Cast Stone and other low temperature, cementitious waste forms. Additional work is needed to elucidate the hydration mechanisms occurring in Cast Stone formulated with highly concentrated salt solutions since these reactions are responsible for determining the performance of the cured waste form. The thermal analyses completed in this study provide some preliminary insight, although the limited

Fox, K.; Roberts, K.; Edwards, T.

2013-09-17T23:59:59.000Z

303

Large-scale sodium spray fire code validation (SOFICOV) test  

Science Conference Proceedings (OSTI)

A large-scale, sodium, spray fire code validation test was performed in the HEDL 850-m/sup 3/ Containment System Test Facility (CSTF) as part of the Sodium Spray Fire Code Validation (SOFICOV) program. Six hundred fifty eight kilograms of sodium spray was sprayed in an air atmosphere for a period of 2400 s. The sodium spray droplet sizes and spray pattern distribution were estimated. The containment atmosphere temperature and pressure response, containment wall temperature response and sodium reaction rate with oxygen were measured. These results are compared to post-test predictions using SPRAY and NACOM computer codes.

Jeppson, D.W.; Muhlestein, L.D.

1985-01-01T23:59:59.000Z

304

New Regenerative Cycle for Vapor Compression Refrigeration  

SciTech Connect

The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient of performance for geothermal heat pumps based on a new regenerative thermodynamic cycle as comparing to existing technology. In order to demonstrate the improved performance of the prototype, it will be compared to published parameters of commercially available geothermal heat pumps manufactured by US and foreign companies. Other objectives are to optimize the design parameters and to determine the economic viability of the new technology. Background (as stated in the proposal): The proposed technology closely relates to EERE mission by improving energy efficiency, bringing clean, reliable and affordable heating and cooling to the residential and commercial buildings and reducing greenhouse gases emission. It can provide the same amount of heating and cooling with considerably less use of electrical energy and consequently has a potential of reducing our nations dependence on foreign oil. The theoretical basis for the proposed thermodynamic cycle was previously developed and was originally called a dynamic equilibrium method. This theory considers the dynamic equations of state of the working fluid and proposes the methods for modification of T-S trajectories of adiabatic transformation by changing dynamic properties of gas, such as flow rate, speed and acceleration. The substance of this proposal is a thermodynamic cycle characterized by the regenerative use of the potential energy of two-phase flow expansion, which in traditional systems is lost in expansion valves. The essential new features of the process are: (1) The application of two-step throttling of the working fluid and two-step compression of its vapor phase. (2) Use of a compressor as the initial step compression and a jet device as a second step, where throttling and compression are combined. (3) Controlled ratio of a working fluid at the first and second step of compression. In the proposed system, the compressor compresses the vapor only to 50-60% of the final pressure, while the additional compression is provided by a jet device using internal potential energy of the working fluid flow. Therefore, the amount of mechanical energy required by a compressor is significantly reduced, resulting in the increase of efficiency (either COP or EER). The novelty of the cycle is in the equipment and in the way the multi-staging is accomplished. The anticipated result will be a new refrigeration system that requires less energy to accomplish a cooling task. The application of this technology will be for more efficient designs of: (1) Industrial chillers, (2) Refrigeration plants, (3) Heat pumps, (4) Gas Liquefaction plants, (5) Cryogenic systems.

Mark J. Bergander

2005-08-29T23:59:59.000Z

305

Enhanced Attenuation Technologies: Passive Soil Vapor Extraction  

SciTech Connect

Passive soil vapor extraction (PSVE) is an enhanced attenuation (EA) approach that removes volatile contaminants from soil. The extraction is driven by natural pressure gradients between the subsurface and atmosphere (Barometric Pumping), or by renewable sources of energy such as wind or solar power (Assisted PSVE). The technology is applicable for remediating sites with low levels of contamination and for transitioning sites from active source technologies such as active soil vapor extraction (ASVE) to natural attenuation. PSVE systems are simple to design and operate and are more cost effective than active systems in many scenarios. Thus, PSVE is often appropriate as an interim-remedial or polishing strategy. Over the past decade, PSVE has been demonstrated in the U.S. and in Europe. These demonstrations provide practical information to assist in selecting, designing and implementing the technology. These demonstrations indicate that the technology can be effective in achieving remedial objectives in a timely fashion. The keys to success include: (1) Application at sites where the residual source quantities, and associated fluxes to groundwater, are relatively low; (2) Selection of the appropriate passive energy source - barometric pumping in cases with a deep vadose zone and barrier (e.g., clay) layers that separate the subsurface from the atmosphere and renewable energy assisted PSVE in other settings and where higher flow rates are required. (3) Provision of sufficient access to the contaminated vadose zones through the spacing and number of extraction wells. This PSVE technology report provides a summary of the relevant technical background, real-world case study performance, key design and cost considerations, and a scenario-based cost evaluation. The key design and cost considerations are organized into a flowchart that dovetails with the Enhanced Attenuation: Chlorinated Organics Guidance of the Interstate Technology and Regulatory Council (ITRC). The PSVE flowchart provides a structured process to determine if the technology is, or is not, reasonable and defensible for a particular site. The central basis for that decision is the expected performance of PSVE under the site specific conditions. Will PSVE have sufficient mass removal rates to reduce the release, or flux, of contamination into the underlying groundwater so that the site can meet it overall remedial objectives? The summary technical information, case study experiences, and structured decision process provided in this 'user guide' should assist environmental decision-makers, regulators, and engineers in selecting and successfully implementing PSVE at appropriate sites.

Vangelas, K.; Looney, B.; Kamath, R.; Adamson, D.; Newell, C.

2010-03-15T23:59:59.000Z

306

Desalination Using Vapor-Compression Distillation  

E-Print Network (OSTI)

The ability to produce potable water economically is the primary purpose of seawater desalination research. Reverse osmosis (RO) and multi-stage flash (MSF) cost more than potable water produced from fresh water resources. As an alternative to RO and MSF, this research investigates a high-efficiency mechanical vapor-compression distillation system that employs an improved water flow arrangement. The incoming salt concentration was 0.15% salt for brackish water and 3.5% salt for seawater, whereas the outgoing salt concentration was 1.5% and 7%, respectively. Distillation was performed at 439 K (331oF) and 722 kPa (105 psia) for both brackish water feed and seawater feed. Water costs of the various conditions were calculated for brackish water and seawater feeds using optimum conditions considered as 25 and 20 stages, respectively. For brackish water at a temperature difference of 0.96 K (1.73oF), the energy requirement is 2.0 kWh/m3 (7.53 kWh/kgal). At this condition, the estimated water cost is $0.39/m3 ($1.48/kgal) achieved with 10,000,000 gal/day distillate, 30-year bond, 5% interest rate, and $0.05/kWh electricity. For seawater at a temperature difference of 0.44 K (0.80oF), the energy requirement is 3.97 kWh/m3 (15.0 kWh/kgal) and the estimated water cost is $0.61/m3 ($2.31/kgal). Greater efficiency of the vapor compression system is achieved by connecting multiple evaporators in series, rather than the traditional parallel arrangement. The efficiency results from the gradual increase of salinity in each stage of the series arrangement in comparison to parallel. Calculations using various temperature differences between boiling brine and condensing steam show the series arrangement has the greatest improvement at lower temperature differences. The following table shows the improvement of a series flow arrangement compared to parallel: ?T (K) Improvement (%)*1.111 2.222 3.333 15.21 10.80 8.37 * Incoming salt concentration: 3.5% Outgoing salt concentration: 7% Temperature: 450 K (350oF) Pressure: 928 kPa (120 psig) Stages: 4

Lubis, Mirna R.

2009-05-01T23:59:59.000Z

307

Numerical simulation of water injection into vapor-dominated reservoirs  

DOE Green Energy (OSTI)

Water injection into vapor-dominated reservoirs is a means of condensate disposal, as well as a reservoir management tool for enhancing energy recovery and reservoir life. We review different approaches to modeling the complex fluid and heat flow processes during injection into vapor-dominated systems. Vapor pressure lowering, grid orientation effects, and physical dispersion of injection plumes from reservoir heterogeneity are important considerations for a realistic modeling of injection effects. An example of detailed three-dimensional modeling of injection experiments at The Geysers is given.

Pruess, K.

1995-01-01T23:59:59.000Z

308

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.

Grossman, Mark W. (Belmont, MA); George, William A. (Rockport, MA)

1988-01-01T23:59:59.000Z

309

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.

Grossman, M.W.; George, W.A.

1988-05-24T23:59:59.000Z

310

Simple microwave field imaging technique using hot atomic vapor cells  

E-Print Network (OSTI)

We demonstrate a simple technique for microwave field imaging using alkali atoms in a vapor cell. The microwave field to be measured drives Rabi oscillations on atomic hyperfine transitions, which are detected in a spatially resolved way using a laser beam and a CCD camera. Our vapor cell geometry enables single-shot recording of two-dimensional microwave field images with 350 {\\mu}m spatial resolution. Using microfabricated vapor cell arrays, a resolution of a few micrometers seems feasible. All vector components of the microwave magnetic field can be imaged. Our apparatus is simple and compact and does not require cryogenics or ultra-high vacuum.

Bhi, Pascal

2012-01-01T23:59:59.000Z

311

Simple microwave field imaging technique using hot atomic vapor cells  

E-Print Network (OSTI)

We demonstrate a simple technique for microwave field imaging using alkali atoms in a vapor cell. The microwave field to be measured drives Rabi oscillations on atomic hyperfine transitions, which are detected in a spatially resolved way using a laser beam and a camera. Our vapor cell geometry enables single-shot recording of two-dimensional microwave field images with 350 {\\mu}m spatial resolution. Using microfabricated vapor cell arrays, a resolution of a few micrometers seems feasible. All vector components of the microwave magnetic field can be imaged. Our apparatus is simple and compact and does not require cryogenics or ultra-high vacuum.

Pascal Bhi; Philipp Treutlein

2012-07-20T23:59:59.000Z

312

Preliminary assessment of halogenated alkanes as vapor-phase tracers  

DOE Green Energy (OSTI)

New tracers are needed to evaluate the efficiency of injection strategies in vapor-dominated environments. One group of compounds that seems to meet the requirements for vapor-phase tracing are the halogenated alkanes (HCFCs). HCFCs are generally nontoxic, and extrapolation of tabulated thermodynamic data indicate that they will be thermally stable and nonreactive in a geothermal environment. The solubilities and stabilities of these compounds, which form several homologous series, vary according to the substituent ratios of fluorine, chlorine, and hydrogen. Laboratory and field tests that will further define the suitability of HCFCs as vapor-phase tracers are under way.

Adams, Michael C.; Moore, Joseph N.; Hirtz, Paul

1991-01-01T23:59:59.000Z

313

Mercury Vapor At Medicine Lake Area (Kooten, 1987) | Open Energy  

Open Energy Info (EERE)

Kooten, 1987) Kooten, 1987) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Medicine Lake Area (Kooten, 1987) Exploration Activity Details Location Medicine Lake Area Exploration Technique Mercury Vapor Activity Date Usefulness could be useful with more improvements DOE-funding Unknown References Gerald K. Van Kooten (1987) Geothermal Exploration Using Surface Mercury Geochemistry Retrieved from "http://en.openei.org/w/index.php?title=Mercury_Vapor_At_Medicine_Lake_Area_(Kooten,_1987)&oldid=386431" Category: Exploration Activities What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

314

Sodium Plugging Test Loop - Nuclear Engineering Division (Argonne)  

NLE Websites -- All DOE Office Websites (Extended Search)

Sodium Plugging Test Loop Sodium Plugging Test Loop Sodium Plugging Test Loop Overview Other Facilities Work with Argonne Contact us For Employees Site Map Help Join us on Facebook Follow us on Twitter NE on Flickr Sodium Plugging Test Loop This experimental setup is part of the Global Nuclear Energy Partnership (GNEP) Advanced Fuel Cycle R&D work carried out at Argonne on advanced sodium component technology. Bookmark and Share For long range sodium technology research and development, employing supercritical CO2 Brayton cycle power conversion technology as an advanced balance of plant technology is being considered. The component that provides the interface between the sodium and supercritical CO2 is a compact heat exchanger known as a printed circuit heat exchanger (PCHE). This heat exchanger has very small coolant flow passages that may foul or

315

Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Obtains Patent for Nuclear Reactor Sodium Cleanup Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment March 28, 2013 - 12:00pm Addthis CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. Piping in the east boiler basement of the sodium processing building was color coded for easy identification. Orange indicates sodium and green identifies cooling water.

316

Low-Pressure Sodium Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics Low-Pressure Sodium Lighting Basics August 16, 2013 - 10:17am Addthis Low-pressure sodium lighting provides more energy-efficient outdoor lighting than high-intensity discharge lighting, but it has very poor color rendition. Typical applications include highway and security lighting, where color is not important. Low-pressure sodium lamps work somewhat like fluorescent lamps. Like high-intensity discharge lighting, low-pressure sodium lamps require up to 10 minutes to start and have to cool before they can restart. Therefore, they are most suitable for applications in which they stay on for hours at a time. They are not suitable for use with motion detectors. The chart below compares low-pressure sodium lamps and high-intensity

317

Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment Idaho Site Obtains Patent for Nuclear Reactor Sodium Cleanup Treatment March 28, 2013 - 12:00pm Addthis CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. CWI engineers Jeff Jones, David Tolman, right, and Kirk Dooley (seated) developed a treatment to safely dissolve a bicarbonate crust and treat and remove the sodium in the Experimental Breeder Reactor-II at the Idaho site. Piping in the east boiler basement of the sodium processing building was color coded for easy identification. Orange indicates sodium and green identifies cooling water.

318

Catalytic Reactor For Oxidizing Mercury Vapor  

DOE Patents (OSTI)

A catalytic reactor (10) for oxidizing elemental mercury contained in flue gas is provided. The catalyst reactor (10) comprises within a flue gas conduit a perforated corona discharge plate (30a, b) having a plurality of through openings (33) and a plurality of projecting corona discharge electrodes (31); a perforated electrode plate (40a, b, c) having a plurality of through openings (43) axially aligned with the through openings (33) of the perforated corona discharge plate (30a, b) displaced from and opposing the tips of the corona discharge electrodes (31); and a catalyst member (60a, b, c, d) overlaying that face of the perforated electrode plate (40a, b, c) opposing the tips of the corona discharge electrodes (31). A uniformly distributed corona discharge plasma (1000) is intermittently generated between the plurality of corona discharge electrode tips (31) and the catalyst member (60a, b, c, d) when a stream of flue gas is passed through the conduit. During those periods when corona discharge (1000) is not being generated, the catalyst molecules of the catalyst member (60a, b, c, d) adsorb mercury vapor contained in the passing flue gas. During those periods when corona discharge (1000) is being generated, ions and active radicals contained in the generated corona discharge plasma (1000) desorb the mercury from the catalyst molecules of the catalyst member (60a, b, c, d), oxidizing the mercury in virtually simultaneous manner. The desorption process regenerates and activates the catalyst member molecules.

Helfritch, Dennis J. (Baltimore, MD)

1998-07-28T23:59:59.000Z

319

Dynamics of nucleation in chemical vapor deposition  

Science Conference Proceedings (OSTI)

We study the evolution of layer morphology during the early stages of metal chemical vapor deposition (CVD) onto Si(100) via pyrolysis of Fe(CO){sub 5} below 250{degrees}C. Scanning tunneling microscopy (STM) shows that nuclei formation is limited by precursor dissociation which occurs on terraces, not at step sites. Also, the average size of clusters formed during CVD is larger than for Fe growth by evaporation (a random deposition process). Based on STM data and Monte Carlo simulations, we conclude that the CVD-growth morphology is affected by preferential dissociation of Fe(CO){sub 5} molecules at existing Fe clusters -- an autocatalytic effect. We demonstrate that nucleation kinetics can be used to control formation of metal nanostructures on chemically tailored surfaces. Reactive sites on Si (001) are first passivated by hydrogen. H atoms are locally removed by electron stimulated desorption using electrons emitted from the STM tip. Subsequent pyrolysis of Fe(CO){sub 5} leads to selective nucleation and growth of Fe films in the areas where H has been removed.

Mayer, T.M.; Adams, D.P.; Swartzentruber, B.S.; Chason, E.

1995-11-01T23:59:59.000Z

320

Modeling of LNG Pool Spreading and Vaporization  

E-Print Network (OSTI)

In this work, a source term model for estimating the rate of spreading and vaporization of LNG on land and sea is introduced. The model takes into account the composition changes of the boiling mixture, the varying thermodynamic properties due to preferential boiling within the mixture and the effect of boiling on conductive heat transfer. The heat, mass and momentum balance equations are derived for continuous and instantaneous spills and mixture thermodynamic effects are incorporated. A parameter sensitivity analysis was conducted to determine the effect of boiling heat transfer regimes, friction, thermal contact/roughness correction parameter and VLE/mixture thermodynamics on the pool spreading behavior. The aim was to provide a better understanding of these governing phenomena and their relative importance throughout the pool lifetime. The spread model was validated against available experimental data for pool spreading on concrete and sea. The model is solved using Matlab for two continuous and instantaneous spill scenarios and is validated against experimental data on cryogenic pool spreading found in literature.

Basha, Omar 1988-

2012-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Occupational Exposure Evaluation of Complex Vapor Mixtures at the Hanford Nuclear Waste Site, Washington Work-site Vapor Characterization  

SciTech Connect

Extensive sampling and analysis has been done over the years to characterize the radioactive and chemical properties of hazardous waste stored in 177 underground tanks at the Hanford site in eastern Washington State. The purpose of these analyses was to evaluate safety and environmental concerns related to tank stability. More recently, characterization studies have broadened to evaluate potential health hazards of chemical vapors at the ground surface, where workers perform maintenance and waste transfer activities. Chemical vapor emissions from underground hazardous waste storage tanks on the Hanford site are a potential concern because workers enter the tank farms on a regular basis for waste retrievals, equipment maintenance, and surveillance. The extensive sampling done during this campaign evaluated vapor concentrations of more than 100 different chemical at 70 sites in and around one section of the tank farms. Sampling identified only four vapors (ammonia, nitrous oxide, nitrosodimethylamine, and nitrosomethylethylamine) that were present above occupational exposure limits. These elevated concentrations were detected only at exhaust stacks and passive breather filter outlets. Beyond five feet from the sources, vapors disperse rapidly. No vapors were measured above 10% of their OELs more than five feet from the source. This suggests that vapor controls can be focused on limited hazard zones around sources. (authors)

Anderson, T. J. [CH2M HILL Hanford Group, Inc. / Environmental Health, P.O. Box 1000, S7-70, Richland, WA 99352 (United States)

2006-07-01T23:59:59.000Z

322

Industrial Heat Pumps Using Solid/Vapor Working Fluids  

E-Print Network (OSTI)

Industrial heat pumps have the potential to reduce the operating costs of chemical and heat treating processes in the chemical, petroleum, paper, dairy, and many other industries. The cost development of fossil fuel and other prime energy require excellent efficiency/cost ratios and hardware designs adaptable to specific process needs, in order to compete with vapor re-compression recovery systems. The state-of-the-art heat pump equipment employing liquid/vapor working fluids fulfills the requirements only in some applications. The employment of solid/vapor complex compounds leads to more cost effective heat recovery, which is due to simple hardware with no moving parts, extraordinary low maintenance effort, excellent temperature lifts avoiding the need of two-stage systems, and low first cost. This paper describes the advantages and disadvantages of solid/vapor working media.

Rockenfeller, U.

1986-06-01T23:59:59.000Z

323

Broadband Water Vapor Transmission Functions for Atmospheric IR Flux Computations  

Science Conference Proceedings (OSTI)

Transmission functions associated with water vapor molecular line and e-type absorption in the IR spectral regions are presented in the form of simple analytical functions and small tables, from which atmospheric IR fluxes and cooling rates can ...

Ming-Dah Chou

1984-05-01T23:59:59.000Z

324

Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers  

Science Conference Proceedings (OSTI)

Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range ...

Refaat Tamer F.; Halama Gary E.; DeYoung Russell J.

2000-07-01T23:59:59.000Z

325

ARM - Field Campaign - Arctic Winter Water Vapor IOP  

NLE Websites -- All DOE Office Websites (Extended Search)

govCampaignsArctic Winter Water Vapor IOP govCampaignsArctic Winter Water Vapor IOP Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign : Arctic Winter Water Vapor IOP 2004.03.09 - 2004.04.09 Lead Scientist : Ed Westwater Data Availability http://www.etl.noaa.gov/programs/2004/wviop/data will contain quicklooks of all of the data. For data sets, see below. Summary During the IOP, the Ground-based Scanning Radiometer of NOAA/ETL, and the ARM MicroWave Radiometer and Microwave Profiler, yielded excellent data over a range of conditions. In all, angular-scanned and calibrated radiometric data from 22.345 to 380 GHz were taken. The Precipitable Water Vapor varied about an order of magnitude from 1 to 10 mm, and surface temperatures varied from about -10 to -40 deg. Celcius. Vaisala RS90

326

Overview of the ARM/FIRE Water Vapor Experiment (AFWEX)  

NLE Websites -- All DOE Office Websites (Extended Search)

Overview of the ARM/FIRE Water Vapor Overview of the ARM/FIRE Water Vapor Experiment (AFWEX) D. C. Tobin, H. E. Revercomb, and D. D. Turner University of Wisconsin-Madison Madison, Wisconsin Introduction An overview of the ARM/FIRE Water Vapor Experiment (AFWEX) is given. This field experiment was conducted during November-December 2000 near the central ground-based Atmospheric Radiation Measurement (ARM) site in north central Oklahoma, and was sponsored jointly by the ARM, the National Aeronautics and Space Administration (NASA) First ISCCP Regional Experiment (FIRE), and the National Polar-orbiting Operational Environmental Satellite System (NPOESS) programs. Its primary goal was to collect accurate measurements of upper-level (~8 to 12 km) water vapor near the ground-based ARM site. These data are being used to determine the accuracy of measurements that are

327

Numerical analysis of vapor flow in a micro heat pipe  

E-Print Network (OSTI)

The vapor flow in a flat plate micro heat pipe with both uniform and linear heat flux boundary conditions has been numerically analyzed. For both types of boundary conditions, the Navier-Stokes equations with steady incompressible two-dimensional flow were solved using the SIMPLE method. The results indicate that the pressure, shear stress, and friction factor under linear heat flux boundary conditions are considerably smoother, and hence, more closely approximate the real situation. As the heat flux increases, the pressure drop increases, but the friction factor demonstrates only a slight change for different heat flux conditions. The size and shape of the micro heat pipe vapor space was shown to have a significant influence on the vapor flow behavior for micro heat pipes. When the vapor space area decreases, the pressure drop, shear stress, and friction factor all significantly increase.

Liu, Xiaoqin

1996-01-01T23:59:59.000Z

328

Intercomparison of Four Commercial Analyzers for Water Vapor Isotope Measurement  

Science Conference Proceedings (OSTI)

The ?18O and ?D of atmospheric water vapor are important tracers in hydrological and ecological studies. Isotope ratio infrared spectroscopy (IRIS) provides an in situ technology for measuring ?18O and ?D in ambient conditions. An intercomparison ...

Xue-Fa Wen; Xuhui Lee; Xiao-Min Sun; Jian-Lin Wang; Ya-Kun Tang; Sheng-Gong Li; Gui-Rui Yu

2012-02-01T23:59:59.000Z

329

Moisture Vertical Structure, Column Water Vapor, and Tropical Deep Convection  

Science Conference Proceedings (OSTI)

The vertical structure of the relationship between water vapor and precipitation is analyzed in 5 yr of radiosonde and precipitation gauge data from the Nauru Atmospheric Radiation Measurement (ARM) site. The first vertical principal component of ...

Christopher E. Holloway; J. David Neelin

2009-06-01T23:59:59.000Z

330

Improved Magnus Form Approximation of Saturation Vapor Pressure  

Science Conference Proceedings (OSTI)

Algorithms, based on Magnus's form equations, are described that minimize the difference between several relationships between temperature and water vapor pressure at saturation that are commonly used in archiving data. The work was initiated in ...

Oleg A. Alduchov; Robert E. Eskridge

1996-04-01T23:59:59.000Z

331

Advanced Chemical Heat Pumps Using Liquid-Vapor Reactions  

E-Print Network (OSTI)

Chemical heat pumps utilizing liquid-vapor reactions can be configured in forms analogous to electric drive vapor-compression heat pumps and heat activated absorption heat pumps. Basic thermodynamic considerations eliminate some heat pumps and place restrictive working fluid requirements on others, but two thermodynamically feasible systems have significant potential advantage over conventional technology. An electric drive reactive heat pump can use smaller heat exchangers and compressor than a vapor-compression machine, and have more flexible operating characteristics. A waste heat driven heat pump (temperature amplifier) using liquid-vapor chemical reactions- can operate with higher coefficient of performance and smaller heat exchangers than an absorption temperature amplifying heat pump. Higher temperatures and larger temperature lifts should also be possible.

Kirol, L.

1987-09-01T23:59:59.000Z

332

Upper-Tropospheric Water Vapor from UARS MLS  

Science Conference Proceedings (OSTI)

Initial results of upper-tropospheric water vapor obtained from the Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) are presented. MLS is less affected by clouds than infrared or visible techniques, and the UARS ...

W. G. Read; J. W. Waters; D. A. Flower; L. Froidevaux; R. F. Jarnot; D. L. Hartmann; R. S. Harwood; R. B. Rood

1995-12-01T23:59:59.000Z

333

Ice Growth from the Vapor at ?5C  

Science Conference Proceedings (OSTI)

Results are summarized and illustrated from a long series of experiments on ice growth from the vapor, nearly all in a very small range of conditions: ?5C, slightly below liquid water saturation, with minimal environmental gradients and no ...

Charles A. Knight

2012-06-01T23:59:59.000Z

334

New Equations for Computing Vapor Pressure and Enhancement Factor  

Science Conference Proceedings (OSTI)

Equations are presented which relate saturation vapor pressure to temperature for moist air. The equations are designed to be easily implemented on a calculator or computer and can be used to convert in either direction. They are more accurate ...

Arden L. Buck

1981-12-01T23:59:59.000Z

335

Solar Radiation Absorption due to Water Vapor: Advanced Broadband Parameterizations  

Science Conference Proceedings (OSTI)

Accurate parameterizations for calculating solar radiation absorption in the atmospheric column due to water vapor lines and continuum are proposed for use in broadband shortwave radiative transfer codes. The error in the absorption values is ...

Tatiana A. Tarasova; Boris A. Fomin

2000-11-01T23:59:59.000Z

336

Water vapor and the dynamics of climate changes  

E-Print Network (OSTI)

Water vapor is not only Earth's dominant greenhouse gas. Through the release of latent heat when it condenses, it also plays an active role in dynamic processes that shape the global circulation of the atmosphere and thus ...

Schneider, Tapio

337

Heat transfer during film condensation of a liquid metal vapor  

E-Print Network (OSTI)

The object of this investigation is to resolve the discrepancy between theory and experiment for the case of heat transfer durirnfilm condensation of liquid metal vapors. Experiments by previous investigators have yielded ...

Sukhatme, S. P.

1964-01-01T23:59:59.000Z

338

Heat transfer during film condensation of potassium vapor  

E-Print Network (OSTI)

The object of this work is to investigate theoretically and experimentally the following two phases of heat transfer during condensation of potassium vapore, a. Heat transfer during film condensation of pure saturated ...

Kroger, Detlev Gustav

1966-01-01T23:59:59.000Z

339

Photoinitiated chemical vapor depostion [sic] : mechanism and applications  

E-Print Network (OSTI)

Photoinitiated chemical vapor deposition (piCVD) is developed as a simple, solventless, and rapid method for the deposition of swellable hydrogels and functional hydrogel copolymers. Mechanistic experiments show that piCVD ...

Baxamusa, Salmaan Husain

2009-01-01T23:59:59.000Z

340

Chemical vapor deposition of organosilicon and sacrificial polymer thin films  

E-Print Network (OSTI)

Chemical vapor deposition (CVD) produced films for a wide array of applications from a variety of organosilicon and organic precursors. The structure and properties of thin films were controlled by varying processing ...

Casserly, Thomas Bryan

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

The Arm Program's Water Vapor Intensive Observation Periods  

Science Conference Proceedings (OSTI)

A series of water vapor intensive observation periods (WVIOPs) were conducted at the Atmospheric Radiation Measurement (ARM) site in Oklahoma between 1996 and 2000. The goals of these WVIOPs are to characterize the accuracy of the operational ...

H. E. Revercomb; D. D. Turner; D. C. Tobin; R. O. Knuteson; W. F. Feltz; J. Barnard; J. Bsenberg; S. Clough; D. Cook; R. Ferrare; J. Goldsmith; S. Gutman; R. Halthore; B. Lesht; J. Liljegren; H. Linn; J. Michalsky; V. Morris; W. Porch; S. Richardson; B. Schmid; M. Splitt; T. Van Hove; E. Westwater; D. Whiteman

2003-02-01T23:59:59.000Z

342

Column Water Vapor Content in Clear and Cloudy Skies  

Science Conference Proceedings (OSTI)

With radiosonde data from 15 Northern Hemisphere stations, surface-to-400-mb column water vapor is computed from daytime soundings for 19881990. On the basis of simultaneous surface visual cloud observations, the data are categorized according ...

Dian J. Gaffen; William P. Elliott

1993-12-01T23:59:59.000Z

343

Initiated chemical vapor deposition of functional polyacrylic thin films  

E-Print Network (OSTI)

Initiated chemical vapor deposition (iCVD) was explored as a novel method for synthesis of functional polyacrylic thin films. The process introduces a peroxide initiator, which can be decomposed at low temperatures (<200?C) ...

Mao, Yu, 1975-

2005-01-01T23:59:59.000Z

344

Mercury Vapor At Kawaihae Area (Thomas, 1986) | Open Energy Information  

Open Energy Info (EERE)

Mercury Vapor At Kawaihae Area (Thomas, 1986) Mercury Vapor At Kawaihae Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Kawaihae Area (Thomas, 1986) Exploration Activity Details Location Kawaihae Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The soil geochemistry yielded quite complex patterns of mercury concentrations and radonemanation rates within the survey area (Cox and Cuff, 1981c). Mercury concentrations (Fig. 38) showed a general minimum along the Kawaihae-Waimea roads and a broad trend of increasing mercury concentrations toward both the north and south. There is no correlation apparent between the mercury patterns and either the resistivity sounding data or the surface geology in the area. The radon emanometry data (Fig.

345

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Lualualei Valley Area (Thomas, 1986) Exploration Activity Details Location Lualualei Valley Area Exploration Technique Mercury Vapor Activity Date Usefulness useful DOE-funding Unknown Notes Soil mercury and radon emanation surveys were performed over much of the accessible surface of Lualualei Valley (Cox and Thomas, 1979). The results of these surveys (Figs 7 and 8) delineated several areas in which soil mercury concentrations or radon emanation rates were substantially above normal background values. Some of these areas were apparently coincident with the mapped fracture systems associated with the caldera boundaries.

346

Raman Lidar Profiling of Tropospheric Water Vapor over Kangerlussuaq, Greenland  

Science Conference Proceedings (OSTI)

A new measurement capability has been implemented in the Arctic Lidar Technology (ARCLITE) system at the Sondrestrom upper-atmosphere research facility near Kangerlussuaq, Greenland (67.0N, 50.9W), enabling estimates of atmospheric water vapor ...

Ryan Reynolds Neely III; Jeffrey P. Thayer

2011-09-01T23:59:59.000Z

347

Lidar Monitoring of the Water Vapor Cycle in the Troposphere  

Science Conference Proceedings (OSTI)

The water vapor mixing ratio distribution in the lower and middle troposphere has been continuously monitored, using an active lidar system. The methodology of the differential absorption laser method used for these measurements is summarized and ...

C. Cahen; G. Megie; P. Flamant

1982-10-01T23:59:59.000Z

348

Report on sodium compatibility of advanced structural materials.  

SciTech Connect

This report provides an update on the evaluation of sodium compatibility of advanced structural materials. The report is a deliverable (level 3) in FY11 (M3A11AN04030403), under the Work Package A-11AN040304, 'Sodium Compatibility of Advanced Structural Materials' performed by Argonne National Laboratory (ANL), as part of Advanced Structural Materials Program for the Advanced Reactor Concepts. This work package supports the advanced structural materials development by providing corrosion and tensile data from the standpoint of sodium compatibility of advanced structural alloys. The scope of work involves exposure of advanced structural alloys such as G92, mod.9Cr-1Mo (G91) ferritic-martensitic steels and HT-UPS austenitic stainless steels to a flowing sodium environment with controlled impurity concentrations. The exposed specimens are analyzed for their corrosion performance, microstructural changes, and tensile behavior. Previous reports examined the thermodynamic and kinetic factors involved in the purity of liquid sodium coolant for sodium reactor applications as well as the design, fabrication, and construction of a forced convection sodium loop for sodium compatibility studies of advanced materials. This report presents the results on corrosion performance, microstructure, and tensile properties of advanced ferritic-martensitic and austenitic alloys exposed to liquid sodium at 550 C for up to 2700 h and at 650 C for up to 5064 h in the forced convection sodium loop. The oxygen content of sodium was controlled by the cold-trapping method to achieve {approx}1 wppm oxygen level. Four alloys were examined, G92 in the normalized and tempered condition (H1 G92), G92 in the cold-rolled condition (H2 G92), G91 in the normalized and tempered condition, and hot-rolled HT-UPS. G91 was included as a reference to compare with advanced alloy, G92. It was found that all four alloys showed weight loss after sodium exposures at 550 and 650 C. The weight loss of the four alloys was comparable after sodium exposures at 550 C; the weight loss of ferritic-martensitic steels, G92 and G91 is more significant than that of austenitic stainless steel, HT-UPS after sodium exposures at 650 C. Sodium exposures up to 2700 h at 550 C had no significant influence on tensile properties, while sodium exposures up to 5064 h at 650 C dramatically lowered the tensile strengths of the four alloys. The ultimate tensile strength of H1 G92, H2 G92, and G91 ferritic-martensitic steels was reduced to as much as nearly half of its initial value after sodium exposures at 650 C. Though the uniform elongation was recovered to some extent, these three ferritic-martensitic steels showed considerable strain softening after sodium exposures. The yield stress of HT-UPS austenitic stainless steel increased, the ultimate tensile strength decreased, and the total elongation was reduced after sodium exposures at 650 C. The dynamic strain aging effect observed in the as-received HT-UPS specimens became less pronounced after sodium exposures at 650 C. Microstructural characterization of sodium-exposed specimens showed no appreciable surface deterioration or grain structure changes under an optical microscope, except for the H2 G92 steel, in which the martensite structure transformed to large grain ferrite after sodium exposures at 650 C. TEM observations of the sodium-exposed H2 G92 steel showed significant recrystallization after sodium exposure for 2700 h at 550 C, and transformation of martensite to ferrite and high density of precipitates in nearly dislocation-free matrix after sodium exposures at 650 C. Further microstructural analysis and evaluation of decarburization/carburization behavior is needed to understand the dramatic changes in the tensile strengths of advanced ferritic-martensitic and austenitic steels after sodium exposures at 650 C.

Li, M.; Natesan, K.; Momozaki, Y.; Rink, D.L.; Soppet, W.K.; Listwan, J.T. (Nuclear Engineering Division)

2012-07-09T23:59:59.000Z

349

Injection locked oscillator system for pulsed metal vapor lasers  

SciTech Connect

An injection locked oscillator system for pulsed metal vapor lasers is disclosed. The invention includes the combination of a seeding oscillator with an injection locked oscillator (ILO) for improving the quality, particularly the intensity, of an output laser beam pulse. The present invention includes means for matching the first seeder laser pulses from the seeding oscillator to second laser pulses of a metal vapor laser to improve the quality, and particularly the intensity, of the output laser beam pulse.

Warner, Bruce E. (Livermore, CA); Ault, Earl R. (Dublin, CA)

1988-01-01T23:59:59.000Z

350

Determination of the Vapor Pressure of Lanthanum Fluoride  

SciTech Connect

Preliminary experiments have been made to determine the vapor pressure of lanthanum fluoride between 0.001 and 0.1 millimeter of mercury by means of the Knudsen effusion method. A tantalum cell for this purpose is described. Only preliminary results were obtained and they were all in a relatively high pressure region. However, a plot of the vapor pressure against the reciprocal of absolute temperature approximates a straight line such as would be predicted from theoretical considerations.

Stone, B. D.

1954-04-07T23:59:59.000Z

351

Heat Recovery in Distillation by Mechanical Vapor Recompression  

E-Print Network (OSTI)

A significant reduction in distillation tower energy requirements can be achieved by mechanical vapor recompression. Three design approaches for heating a distillation tower reboiler by mechanical vapor recompression are presented. The advantages of using a screw compressor are discussed in detail. An example of a xylene extraction tower is sited, illustrating the economic attractiveness in which a simple payback period of less than two years is achievable.

Becker, F. E.; Zakak, A. I.

1986-06-01T23:59:59.000Z

352

Super-radiance in the sodium resonance lines from sodium iodide arc lamps  

Science Conference Proceedings (OSTI)

Super-radiance observed within the centers of the sodium resonance D lines emitted by arc lamps containing sodium iodide as additive in a high-pressure mercury plasma environment was studied by high-resolution emission spectroscopy. The spectral radiance of these self-reversed lines including super-radiance was simulated by considering a local enhancement of the source function due to the presence of an additional source of radiation near the arc wall. Causes of this hitherto unrecognized source of radiation are given.

Karabourniotis, D. [Department of Physics, Institute of Plasma Physics, University of Crete, 71003 Heraklion (Greece); Drakakis, E. [Department of Electrical Engineering, Technological Educational Institute, Heraklion (Greece)

2010-08-09T23:59:59.000Z

353

Factors contributing to the breakdown of sodium beta-alumina  

DOE Green Energy (OSTI)

Clarification of the breakdown process occurring during charge transfer in sodium beta alumina solid electrolytes was derived from: (1) studying the effects of molten sodium contact at 350/sup 0/C on single crystal sodium beta alumina and polycrystalline sodium beta alumina; (2) determination of critical current density by monitoring acoustic emissions accompanying crack growth in sodium/sodium beta alumina/sodium cells subjected to linear current ramping at 1 mA cm/sup -2/ sec/sup -1/; (3) failure analysis conducted on cycled electrolytes, some from commercial sodium/sulfur cells, which had been subjected to up to 703 Ahr cm/sup -2/ of charge transfer. Gray coloration developing in beta aluminas in contact with molten sodium was found to be a consequence of formation, through reduction by sodium, of oxygen vacancies charge compensated by electrons. Electronic conductivity of the electrolyte increases as a result. No second phase formation was detected. Colored electrolytes from sodium/sulfur cells show evidence of a newly recognized degradation mechanism in which fracture occurs when sodium is reduced and deposited internally under pressure as metal in regions where an electronic conductivity gradient exists. Heating colored beta aluminas in air produces reoxidation and bleaching. Kinetics and other properties of the coloration and bleaching processes were determined. Critical current density was found to bear an inverse relation to average electrolyte grain size. Evidence was found in the cycled electrolytes for a slow crack growth mechanism and a progressive mode of degradation advancing from the sulfur electrode interface. Implications of the findings for the construction and operation of sodium/sulfur battery systems are discussed.

Buechele, A.C.

1982-05-01T23:59:59.000Z

354

ARM: Microwave Radiometer data (MWR Profiles - QME), water vapor, temp, cloud liquid water, precip water retrievals  

DOE Data Explorer (OSTI)

Microwave Radiometer data (MWR Profiles - QME), water vapor, temp, cloud liquid water, precip water retrievals

Maria Cadeddu

355

Low temperature plasma enhanced chemical vapor deposition of silicon oxide films using disilane and nitrous oxide  

Science Conference Proceedings (OSTI)

Keywords: disilane, low temperature, nitrous oxide, plasma enhanced chemical vapor deposition, silicon oxide

Juho Song; G. S. Lee; P. K. Ajmera

1995-10-01T23:59:59.000Z

356

Fact Sheet: Sodium-Beta Batteries (October 2012)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sodium-Beta Batteries Sodium-Beta Batteries Improving the performance and reducing the cost of sodium-beta batteries for large-scale energy storage Sodium-beta batteries (Na-beta batteries or NBBs) use a solid beta-alumina (ß˝-Al 2 O 3 ) electrolyte membrane that selectively allows sodium ion transport between a positive electrode (e.g., a metal halide) and a negative sodium electrode. NBBs typically operate at temperatures near 350˚C. They are increasingly used in renewable storage and utility applications due to their high round-trip efficiency, high energy densities, and energy storage capacities ranging from a few kilowatt-hours to multiple megawatt-hours. In fact, U.S. utilities

357

Sodium/Phosphorus-Sulfur Cells II. Phase Equilibria  

NLE Websites -- All DOE Office Websites (Extended Search)

II. Phase Equilibria II. Phase Equilibria Title Sodium/Phosphorus-Sulfur Cells II. Phase Equilibria Publication Type Journal Article Year of Publication 1996 Authors Ridgway, Paul L., Frank R. McLarnon, and John S. Newman Journal Journal of the Electrochemistry Society Volume 143 Issue 2 Pagination 412-417 Keywords 25 ENERGY STORAGE, 36 MATERIALS SCIENCE, ALUMINIUM OXIDES, equilibrium, performance, PHASE DIAGRAMS, PHOSPHIDES, PHOSPHORUS ADDITIONS, SODIUM COMPOUNDS, SODIUM SULFIDES, SODIUM-SULFUR BATTERIES Abstract Equilibrium open-circuit cell voltage data from a sodium/{beta}{double_prime}-alumina/phosphorus-sulfur cell utilizing P/S ratios of 0, 0.143, and 0.332 and a sodium atom fraction ranging from 0 to 0.4 were interpreted to construct ternary phase diagrams of the Na-P-S ternary system at 350 and 400 C.

358

City of Mishawaka, Indiana (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Indiana (Utility Company) Indiana (Utility Company) Jump to: navigation, search Name City of Mishawaka Place Indiana Utility Id 12674 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes RTO PJM Yes Activity Buying Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Power Service Commercial Commerical(10kW or more) Commercial Commerical(less than 10kW) Commercial Electric Heating Commercial Municipal Electric Service Commercial Outdoor lighting- 1,000 watt mercury vapor lamp Lighting Outdoor lighting- 100 watt sodium lamp Lighting Outdoor lighting- 175 watt mercury vapor lamp Lighting

359

Review of Chemical Processes for the Synthesis of Sodium Borohydride  

NLE Websites -- All DOE Office Websites (Extended Search)

Review of Chemical Processes for the Synthesis of Sodium Borohydride Review of Chemical Processes for the Synthesis of Sodium Borohydride Millennium Cell Inc. Prepared by Ying Wu Michael T. Kelly Jeffrey V. Ortega Under DOE Cooperative Agreement DE-FC36-04GO14008 August 2004 Table of Contents Introduction..................................................................................................................................... 1 Section 1: Commercially Practiced Sodium Borohydride Synthesis Process ............................... 2 The Brown-Schlesinger Process ................................................................................................. 2 The Bayer Process.......................................................................................................................

360

METHOD FOR REDUCING THE IMPURITY RESISTIVITY OF SODIUM  

DOE Patents (OSTI)

The inherent resistivity of sodium, at cryogenic temperatures, can be reduced by clustering the impurity atoms within the crystal latiice structure of the sodium, thereby reducing the effective electron collision cross section and thus reducing the number of collisions between the electrons and such lattice imperfections. The clustering is effected by heating the sodium to a temperature approaching its melting point, and maintaining the temperature for a period of time ranging generally from two to six days. (AEC)

Post, R.F.; Taylor, C.E.

1963-08-13T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

PROCESSING OF SODIUM--POTASSIUM NIOBATE CERAMICS.  

SciTech Connect

Sintering studies of undoped (Na{sub 0.5}K{sub 0.5})NbO{sub 3} and the same material doped with 1/2, 1, 2, and 4 mole percent BaO and 2 mole % B{sub 2}O{sub 3} were made. The persistence of a second phase after calcining to form the compound led to a study of reactions occurring during calcination. The calcining of sodium-potassium niobates involves the formation of an intermediate compound (the second phase) and its subsequent reaction with sodium oxide and potassium oxide to form (Na{sub 0.5}K{sub 0.5})NbO{sub 3}. Sintering data show that up to 1/2 mole % BaO added to the system increases the initial densification. However, the sintered bodies then exhibit densification and form sharp cubic grains and large voids. Indications are that a liquid phase is the major contributor to densification of this system through the mechanism of particle rearrangement, and that the contribution of any sintering mechanism to densification is negligible.

Powell, B.R. Jr.

1971-01-01T23:59:59.000Z

362

Sodium Reactor Experiment decommissioning. Final report  

Science Conference Proceedings (OSTI)

The Sodium Reactor Experiment (SRE) located at the Rockwell International Field Laboratories northwest of Los Angeles was developed to demonstrate a sodium-cooled, graphite-moderated reactor for civilian use. The reactor reached full power in May 1958 and provided 37 GWh to the Southern California Edison Company grid before it was shut down in 1967. Decommissioning of the SRE began in 1974 with the objective of removing all significant radioactivity from the site and releasing the facility for unrestricted use. Planning documentation was prepared to describe in detail the equipment and techniques development and the decommissioning work scope. A plasma-arc manipulator was developed for remotely dissecting the highly radioactive reactor vessels. Other important developments included techniques for using explosives to cut reactor vessel internal piping, clamps, and brackets; decontaminating porous concrete surfaces; and disposing of massive equipment and structures. The documentation defined the decommissioning in an SRE dismantling plan, in activity requirements for elements of the decommissioning work scope, and in detailed procedures for each major task.

Carroll, J.W.; Conners, C.C.; Harris, J.M.; Marzec, J.M.; Ureda, B.F.

1983-08-15T23:59:59.000Z

363

Sodium Bearing Waste Treatment Project ? Countdown to Startup  

NLE Websites -- All DOE Office Websites (Extended Search)

Date: March 19, 2012 Media Contact: Natalie Packer, 208-533-0253 Sodium Bearing Waste Treatment Project Countdown to Startup Marking completion of another major...

364

Energy absorber for sodium-heated heat exchanger  

DOE Patents (OSTI)

A heat exchanger is described in which water-carrying tubes are heated by liquid sodium and in which the results of accidental contact between the water and the sodium caused by failure of one or more of the water tubes is minimized. An energy absorbing chamber contains a compressible gas and is connected to the body of flowing sodium by a channel so that, in the event of a sodium-water reaction, products of the reaction will partially fill the energy absorbing chamber to attenuate the rise in pressure within the heat exchanger.

Essebaggers, J.

1975-12-01T23:59:59.000Z

365

Battery Electrode Materials Based on Layered Sodium Titanates  

Berkeley Lab researcher Marca Doeff and colleagues have developed a new electrode material based on a layered sodium titanate compound that can be ...

366

Low Temperature Sodium-Sulfur Grid Storage and EV Battery  

Berkeley Lab researcher Gao Liu has developed an innovative design for a battery, made primarily of sodium and sulfur, that holds promise for both ...

367

Low Temperature Sodium-Sulfur Grid Storage and EV Battery ...  

Berkeley Lab researcher Gao Liu has developed an innovative design for a battery, made primarily of sodium and sulfur, that holds promise for both large-scale grid ...

368

NASICON-Type Electrolytes for Low Temperature Sodium Battery ...  

Science Conference Proceedings (OSTI)

Presentation Title, NASICON-Type Electrolytes for Low Temperature Sodium Battery Applications. Author(s), Hui Zhang, Xingbo Liu. On-Site Speaker ( Planned)...

369

ESS 2012 Peer Review - Sodium Intercalation Battery for Stationary...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

LLC 35 Hartwell Avenue Lexington, MA 02421-3102 www.TIAXLLC.com Sodium Intercalation Battery for Stationary Storage Energy Storage Systems Program (ESS) Peer Review and Update...

370

Sodium cobalt bronze batteries and a method for making same  

SciTech Connect

A solid state secondary battery utilizing a low cost, environmentally sound, sodium cobalt bronze electrode. A method is provided for producing same.

Doeff, Marca M. (Hayward, CA); Ma, Yanping (Berkeley, CA); Visco, Steven J. (Berkeley, CA); DeJonghe, Lutgard (Lafayette, CA)

1999-01-01T23:59:59.000Z

371

Reductive Sulfur-fixation Smelting of Stibnite Concentrate in Sodium ...  

Science Conference Proceedings (OSTI)

Abstract Scope, A new process to extracted antimony directly from stibnite concentrate by reductive sulfur-fixation smelting in sodium molten salt has been...

372

Influence of Petroleum Coke Sulphur Content on the Sodium ... - TMS  

Science Conference Proceedings (OSTI)

Feb 1, 1993 ... Influence of Petroleum Coke Sulphur Content on the Sodium Sensitivity of Carbon Anodes by S.M. Hume ... TMS Student Member price: 0.00.

373

Sodium cobalt bronze batteries and a method for making same  

DOE Patents (OSTI)

A solid state secondary battery utilizing a low cost, environmentally sound, sodium cobalt bronze electrode is described. A method is provided for producing same. 11 figs.

Doeff, M.M.; Ma, Y.; Visco, S.J.; DeJonghe, L.

1999-06-29T23:59:59.000Z

374

Planar Sodium Metal Halide Battery for Renewable Integration and ...  

Science Conference Proceedings (OSTI)

In this work we will present a sodium ߔ-alumina cell designed for widespread renewable energy integration and electrical grid applications. The new generation...

375

Sodium fast reactor safety and licensing research plan. Volume II.  

SciTech Connect

Expert panels comprised of subject matter experts identified at the U.S. National Laboratories (SNL, ANL, INL, ORNL, LBL, and BNL), universities (University of Wisconsin and Ohio State University), international agencies (IRSN, CEA, JAEA, KAERI, and JRC-IE) and private consultation companies (Radiation Effects Consulting) were assembled to perform a gap analysis for sodium fast reactor licensing. Expert-opinion elicitation was performed to qualitatively assess the current state of sodium fast reactor technologies. Five independent gap analyses were performed resulting in the following topical reports: (1) Accident Initiators and Sequences (i.e., Initiators/Sequences Technology Gap Analysis), (2) Sodium Technology Phenomena (i.e., Advanced Burner Reactor Sodium Technology Gap Analysis), (3) Fuels and Materials (i.e., Sodium Fast Reactor Fuels and Materials: Research Needs), (4) Source Term Characterization (i.e., Advanced Sodium Fast Reactor Accident Source Terms: Research Needs), and (5) Computer Codes and Models (i.e., Sodium Fast Reactor Gaps Analysis of Computer Codes and Models for Accident Analysis and Reactor Safety). Volume II of the Sodium Research Plan consolidates the five gap analysis reports produced by each expert panel, wherein the importance of the identified phenomena and necessities of further experimental research and code development were addressed. The findings from these five reports comprised the basis for the analysis in Sodium Fast Reactor Research Plan Volume I.

Ludewig, H. (Brokhaven National Laboratory, Upton, NY); Powers, D. A.; Hewson, John C.; LaChance, Jeffrey L.; Wright, A. (Argonne National Laboratory, Argonne, IL); Phillips, J.; Zeyen, R. (Institute for Energy Petten, Saint-Paul-lez-Durance, France); Clement, B. (IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France); Garner, Frank (Radiation Effects Consulting, Richland, WA); Walters, Leon (Advanced Reactor Concepts, Los Alamos, NM); Wright, Steve; Ott, Larry J. (Oak Ridge National Laboratory, Oak Ridge, TN); Suo-Anttila, Ahti Jorma; Denning, Richard (Ohio State University, Columbus, OH); Ohshima, Hiroyuki (Japan Atomic Energy Agency, Ibaraki, Japan); Ohno, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Miyhara, S. (Japan Atomic Energy Agency, Ibaraki, Japan); Yacout, Abdellatif (Argonne National Laboratory, Argonne, IL); Farmer, M. (Argonne National Laboratory, Argonne, IL); Wade, D. (Argonne National Laboratory, Argonne, IL); Grandy, C. (Argonne National Laboratory, Argonne, IL); Schmidt, R.; Cahalen, J. (Argonne National Laboratory, Argonne, IL); Olivier, Tara Jean; Budnitz, R. (Lawrence Berkeley National Laboratory, Berkeley, CA); Tobita, Yoshiharu (Japan Atomic Energy Agency, Ibaraki, Japan); Serre, Frederic (Centre d'%C3%94etudes nucl%C3%94eaires de Cadarache, Cea, France); Natesan, Ken (Argonne National Laboratory, Argonne, IL); Carbajo, Juan J. (Oak Ridge National Laboratory, Oak Ridge, TN); Jeong, Hae-Yong (Korea Atomic Energy Research Institute, Daejeon, Korea); Wigeland, Roald (Idaho National Laboratory, Idaho Falls, ID); Corradini, Michael (University of Wisconsin-Madison, Madison, WI); Thomas, Justin (Argonne National Laboratory, Argonne, IL); Wei, Tom (Argonne National Laboratory, Argonne, IL); Sofu, Tanju (Argonne National Laboratory, Argonne, IL); Flanagan, George F. (Oak Ridge National Laboratory, Oak Ridge, TN); Bari, R. (Brokhaven National Laboratory, Upton, NY); Porter D. (Idaho National Laboratory, Idaho Falls, ID); Lambert, J. (Argonne National Laboratory, Argonne, IL); Hayes, S. (Idaho National Laboratory, Idaho Falls, ID); Sackett, J. (Idaho National Laboratory, Idaho Falls, ID); Denman, Matthew R.

2012-05-01T23:59:59.000Z

376

Atmospheric-Pressure Chemical Vapor Deposition of Iron Pyrite Thin Films  

Science Conference Proceedings (OSTI)

Iron pyrite (cubic FeS{sub 2}) is a promising candidate absorber material for earth-abundant thin-film solar cells. In this report, single-phase, large-grain, and uniform polycrystalline pyrite thin films are fabricated on glass and molybdenum-coated glass substrates by atmospheric-pressure chemical vapor deposition (AP-CVD) using the reaction of iron(III) acetylacetonate and tert-butyl disulfide in argon at 300 C, followed by sulfur annealing at 500--550 C to convert marcasite impurities to pyrite. The pyrite-marcasite phase composition depends strongly on the concentration of sodium in the growth substrate and the sulfur partial pressure during annealing. Phase and elemental composition of the films are characterized by X-ray diffraction, Raman spectroscopy, Auger electron spectroscopy, secondary ion mass spectrometry, Rutherford backscattering spectrometry, and X-ray photoelectron spectroscopy. The in-plane electrical properties are surprisingly insensitive to phase and elemental impurities, with all films showing p-type, thermally activated transport with a small activation energy ({approx}30 meV), a room- temperature resistivity of {approx}1 {Omega} cm, and low mobility. These ubiquitous electrical properties may result from robust surface effects. These CVD pyrite thin films are well suited to fundamental electrical studies and the fabrication of pyrite photovoltaic device stacks.

Berry, Nicholas; Cheng, Ming; Perkins, Craig L.; Limpinsel, Moritz; Hemminger, John C.; Law, Matt (NREL); (UCI)

2012-10-23T23:59:59.000Z

377

City of Lincoln Center, Kansas (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Center, Kansas (Utility Company) Center, Kansas (Utility Company) Jump to: navigation, search Name City of Lincoln Center Place Kansas Utility Id 11017 Utility Location Yes Ownership M NERC Location SPP NERC SPP Yes RTO SPP Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png City Commercial Dusk to Dawn Yardlights- 100 Watt HP Sodium Lighting City Commercial Dusk to Dawn Yardlights- 175 Watt Merc. Vapor Lighting City Commercial Dusk to Dawn Yardlights- 250 Watt HP Sodium Lighting

378

Monroe County Elec Power Assn | Open Energy Information  

Open Energy Info (EERE)

Power Assn Power Assn Place Mississippi Utility Id 40303 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rate Over 50 KW Commercial Commercial Rate Under 50 KW Commercial Demand Rate Outdoor Lights -100 watt Sodium Lighting Outdoor Lights 175 watt Mercury Vapor Lighting Outdoor Lights 400 watt Sodium Lighting Residential Rate Residential Average Rates Residential: $0.0916/kWh Commercial: $0.1110/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

379

Greenwood Commissioners-Pub Wk | Open Energy Information  

Open Energy Info (EERE)

Commissioners-Pub Wk Commissioners-Pub Wk Jump to: navigation, search Name Greenwood Commissioners-Pub Wk Place South Carolina Utility Id 7646 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large Commercial Service rate V2 Commercial Large Commercial service rate Commercial Large Power service rate Industrial Large Power service rate V2 Industrial Lighting Service - 175 Watt Mercury Vapor Lighting Lighting service - 100 Watt High Pressure Sodium Lighting Lighting service - 1000 Watt High Pressure Sodium Lighting

380

Comanche County Elec Coop Assn | Open Energy Information  

Open Energy Info (EERE)

Comanche County Elec Coop Assn Comanche County Elec Coop Assn Jump to: navigation, search Name Comanche County Elec Coop Assn Place Texas Utility Id 4295 Utility Location Yes Ownership C NERC Location TRE NERC ERCOT Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Service - Three Phase Service Commercial General Service-Single Phase Commercial Large Power Rate Industrial Large Power Rate Primary Metering Industrial Residential Residential SECURITY LIGHTS:100 watt HP Sodium Lighting SECURITY LIGHTS:175 watt Mercury Vapor Lighting SECURITY LIGHTS:250 watt HP Sodium Lighting

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Delta Electric Power Assn | Open Energy Information  

Open Energy Info (EERE)

Delta Electric Power Assn Delta Electric Power Assn Place Mississippi Utility Id 22815 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png 01 Farm and Residential Electric Service Residential 09 Residential Electric Service Water Heater Residential 10 All Electric Residential Service Residential 12 Small Commercial Service Commercial 13 Street Lighting High Pressure Sodium 100 Watt Lighting 13 Street Lighting High Pressure Sodium 400 Watt Lighting 13 Street Lighting Mercury Vapor 175 Watt enclosed Lighting

382

Environmental, health, and safety issues of sodium-sulfur batteries for electric and hybrid vehicles. Volume 3, Transport of sodium-sulfur and sodium-metal-chloride batteries  

DOE Green Energy (OSTI)

This report examines the shipping regulations that govern the shipment of dangerous goods. Since the elemental sodium contained in both sodium-sulfur and sodium-metal-chloride batteries is classified as a dangerous good, and is listed on both the national and international hazardous materials listings, both national and international regulatory processes are considered in this report The interrelationships as well as the differences between the two processes are highlighted. It is important to note that the transport regulatory processes examined in this report are reviewed within the context of assessing the necessary steps needed to provide for the domestic and international transport of sodium-beta batteries. The need for such an assessment was determined by the Shipping Sub-Working Group (SSWG) of the EV Battery Readiness Working Group (Working Group), created in 1990. The Working Group was created to examine the regulatory issues pertaining to in-vehicle safety, shipping, and recycling of sodium-sulfur batteries, each of which is addressed by a sub-working group. The mission of the SSWG is to establish basic provisions that will ensure the safe and efficient transport of sodium-beta batteries. To support that end, a proposal to the UN Committee of Experts was prepared by the SSWG, with the goal of obtaining a proper shipping name and UN number for sodium-beta batteries and to establish the basic transport requirements for such batteries (see the appendix for the proposal as submitted). It is emphasized that because batteries are large articles containing elemental sodium and, in some cases, sulfur, there is no existing UN entry under which they can be classified and for which modal transport requirements, such as the use of packaging appropriate for such large articles, are provided for. It is for this reason that a specific UN entry for sodium-beta batteries is considered essential.

Hammel, C.J.

1992-09-01T23:59:59.000Z

383

Dynamic modeling of plasma-vapor interactions during plasma disruptions  

SciTech Connect

Intense deposition of energy in short times on fusion reactor components during a plasma disruption may cause severe surface erosion due to ablation of these components. The exact amount of the eroded material is very important to the reactor design and its lifetime. During the plasma deposition, the vaporized wall material will interact with the incoming plasma particles and may shield the rest of the wall from damage. The vapor shielding may then prolong the lifetime of these components and increase the reactor duty cycle. To correctly evaluate the impact of vapor shielding effect a comprehensive model is developed. In this model the dynamic slowing down of the plasma particles, both ions and electrons, with the eroded wall material is established. Different interaction processes between the plasma particles and the ablated material is included. The generated photons radiation source and the transport of this radiation through the vapor to the wall is modeled. Recent experimental data on disruptions is analyzed and compared with model predictions. Vapor shielding may be effective in reducing the overall erosion rate for certain plasma disruption parameters and conditions.

Hassanein, A.; Ehst, D.A.

1992-05-01T23:59:59.000Z

384

Vapor etching of nuclear tracks in dielectric materials  

DOE Patents (OSTI)

A process involving vapor etching of nuclear tracks in dielectric materials for creating high aspect ratio (i.e., length much greater than diameter), isolated cylindrical holes in dielectric materials that have been exposed to high-energy atomic particles. The process includes cleaning the surface of the tracked material and exposing the cleaned surface to a vapor of a suitable etchant. Independent control of the temperatures of the vapor and the tracked materials provide the means to vary separately the etch rates for the latent track region and the non-tracked material. As a rule, the tracked regions etch at a greater rate than the non-tracked regions. In addition, the vapor-etched holes can be enlarged and smoothed by subsequent dipping in a liquid etchant. The 20-1000 nm diameter holes resulting from the vapor etching process can be useful as molds for electroplating nanometer-sized filaments, etching gate cavities for deposition of nano-cones, developing high-aspect ratio holes in trackable resists, and as filters for a variety of molecular-sized particles in virtually any liquid or gas by selecting the dielectric material that is compatible with the liquid or gas of interest.

Musket, Ronald G. (Danville, CA); Porter, John D. (Berkeley, CA); Yoshiyama, James M. (Fremont, CA); Contolini, Robert J. (Lake Oswego, OR)

2000-01-01T23:59:59.000Z

385

Drying of pulverized material with heated condensible vapor  

DOE Patents (OSTI)

Apparatus for drying pulverized material utilizes a high enthalpy condensable vapor such as steam for removing moisture from the individual particles of the pulverized material. The initially wet particulate material is tangentially delivered by a carrier vapor flow to an upper portion of a generally vertical cylindrical separation drum. The lateral wall of the separation drum is provided with a plurality of flow guides for directing the vapor tangentially therein in the direction of particulate material flow. Positioned concentrically within the separation drum and along the longitudinal axis thereof is a water-cooled condensation cylinder which is provided with a plurality of collection plates, or fines, on the outer lateral surface thereof. The cooled collection fines are aligned counter to the flow of the pulverized material and high enthalpy vapor mixture to maximize water vapor condensation thereon. The condensed liquid which includes moisture removed from the pulverized materials then flows downward along the outer surface of the coolant cylinder and is collected and removed. The particles travel in a shallow helix due to respective centrifugal and vertical acceleration forces applied thereto. The individual particles of the pulverized material are directed outwardly by the vortex flow where they contact the inner cylindrical surface of the separation drum and are then deposited at the bottom thereof for easy collection and removal. The pulverized material drying apparatus is particularly adapted for drying coal fines and facilitates the recovery of the pulverized coal. 2 figs.

Carlson, L.W.

1984-08-16T23:59:59.000Z

386

Vaporization behavior of non-stoichiometric refractory carbide materials and direct observations of the vapor phase using laser diagnostics  

DOE Green Energy (OSTI)

Transition metal and actinide carbides, such as ZrC or NbC and UC or ThC, exhibit a wide range of stoichiometry, and therefore vaporize incongruently. At long times, steady state vaporization can be achieved where relative concentrations of atomic species on solid surface equals that in the gas phase. The surface composition under these steady state conditions is termed the congruently vaporizing composition, (CVC). Modeling the vaporization or corrosion behavior of this dynamic process is complex and requires an understanding of how the surface composition changes with time and a knowledge of CVC, which is both temperature and atmosphere dependent. This paper describes vaporization and corrosion behavior of non-stoichiometric refractory carbide materials and, as an example, describes a thermokinetic model that characterizes the vaporization behavior of the complex carbide U{sub x}Zr{sub 1-x}C{sub y} in hydrogen at 2500 to 3200 K. This model demonstrates that steady state corrosion of U{sub x}Zr{sub l-x}C{sub y} is rate limited by gaseous transport of Zr where partial pressure of Zr is determined by CVC. This paper also briefly describes efforts to image and characterize the vapor phase above the surface of ZrC in static and flowing gas environments using planar laser induced fluorescence. We have developed the method for monitoring and controlling the corrosion behavior of nuclear fuels in nuclear thermal rockets. However, the techniques described can be used, to image boundary layers, and could be used verifying corrosion models.

Butt, D.P.; Wantuck, P.J.; Rehse, S.J.; Wallace, T.C. Sr.

1993-09-01T23:59:59.000Z

387

Sodium waste technology: A summary report. [Melt-drain-evaporation-calcination (MEDEC)  

SciTech Connect

The Sodium Waste Technology (SWT) Program was established to resolve long-standing issues regarding disposal of sodium-bearing waste and equipment. Comprehensive SWT research programs investigated a variety of approaches for either removing sodium from sodium-bearing items, or disposal of items containing sodium residuals. The most successful of these programs was the design, test, and the production operation of the Sodium Process Demonstration Facility at ANL-W. The technology used was a series of melt-drain-evaporate operations to remove nonradioactive sodium from sodium-bearing items and then converting the sodium to storable compounds.

Abrams, C.S.; Witbeck, L.C.

1987-01-01T23:59:59.000Z

388

An advanced vapor-compression desalination system  

E-Print Network (OSTI)

Currently, the two dominant desalination methods are reverse osmosis (RO) and multi-stage flash (MSF). RO requires large capital investment and maintenance, whereas MSF is too energy intensive. An innovative vapor-compression desalination system is developed in this study. A comprehensive mathematical model for the heat exchanger/evaporator is described. The literature indicates that extraordinarily high overall heat transfer coefficients for the evaporator are possible at selected operating conditions that employ dropwise condensation in the steam side and pool boiling in the liquid side. A smooth titanium surface is chosen to promote dropwise condensation and to resist corrosion. To maximize energy efficiency, a combined-cycle cogeneration scheme is employed composed of a gas turbine, a heat recovery boiler, and a steam turbine that drive a compressor. The combined-cycle power source is oversized relative to the needs of the compressor. The excess power is converted to electricity and sold to the open market. A three-effect evaporator is employed. It is fed with seawater, assumed to be 3.5% salt. Boiling brine (7% salt) is in the low pressure side of the heat exchanger and condensing steam is in the high-pressure side of the heat exchanger. The condensing steam flows at 1.52 m/s (5 ft/s), which maximizes the heat transfer coefficient. The plant is sized to produce 37,854 m3/d (10 mill gal/day) and is assumed to be financed with a 5%, 30-yr municipal bond. Two economic cases were emphasized: the United States and the Middle East. For the United States, the fuel costs $5/GJ ($5.27/mill Btu) with the latent heat exchanger at ( ) 1.11 K 2.00 F T ? = ° . The required compressor energy is 14 MJ/m3 (14.7 kW h/thous gal). The capital cost for the U.S. is $884 d/m3 ($3,342/thous gal) and the delivered water selling price is $0.47/m3 ($1.79/thous/gal). For the Middle East, the fuel costs $0.5/GJ ($0.53/mill Btu) with the latent heat exchanger at K T 33 . 3 = ? ( ) F 00 . 6 ° . The required compressor energy is 26 MJ/m3 (27.3 kW h/thous gal). ). The capital cost for the Middle East is $620 d/m3 ($2,344/thous gal), and the delivered water selling price is $0.25/m3 ($0.95/thous/gal). In all cases, the water selling price is attractive relative to competing technologies.

Lara Ruiz, Jorge Horacio Juan

2005-12-01T23:59:59.000Z

389

Low temperature photochemical vapor deposition of alloy and mixed metal oxide films  

DOE Patents (OSTI)

Method and apparatus for formation of an alloy thin film, or a mixed metal oxide thin film, on a substrate at relatively low temperatures. Precursor vapor(s) containing the desired thin film constituents is positioned adjacent to the substrate and irradiated by light having wavelengths in a selected wavelength range, to dissociate the gas(es) and provide atoms or molecules containing only the desired constituents. These gases then deposit at relatively low temperatures as a thin film on the substrate. The precursor vapor(s) is formed by vaporization of one or more precursor materials, where the vaporization temperature(s) is selected to control the ratio of concentration of metals present in the precursor vapor(s) and/or the total precursor vapor pressure.

Liu, David K. (San Pablo, CA)

1992-01-01T23:59:59.000Z

390

Validation of TES Temperature and Water Vapor Retrievals with ARM  

NLE Websites -- All DOE Office Websites (Extended Search)

Validation of TES Temperature and Water Vapor Retrievals with ARM Validation of TES Temperature and Water Vapor Retrievals with ARM Observations Cady-Pereira, Karen Atmospheric and Environmental Research, Inc. Shephard, Mark Atmospheric and Environmental Research, Inc. Clough, Shepard Atmospheric and Environmental Research Mlawer, Eli Atmospheric & Environmental Research, Inc. Turner, David University of Wisconsin-Madison Category: Atmospheric State and Surface The primary objective of the TES (Tropospheric Emission Spectrometer) instrument on the Aura spacecraft is the retrieval of trace gases, especially water vapor and ozone. The TES retrievals extremely useful for global monitoring of the atmospheric state, but they must be validated. The ARM sites are well instrumented and provide continuous measurements, which

391

High temperature vapor pressure and the critical point of potassium  

SciTech Connect

The vapor pressure of potassium was experimentally determined from 2100 deg F up to-its critical temperature. An empirical equation of the form ln P = A + B/T + C ln T + DT/sup 1.5/ was found to best fit the data. A critical pressure of 2378.2 plus or minus 4.0 psia (161.79 plus or minus 0.27 ata) was measured. The corresponding critical temperature, extrapolated from the pressure-- temperature curve, is 4105.4 plus or minus 5 deg R (2280.8 plus or minus 3 deg K). The technique employed was tae pressure tube method developed earlier in this laboratory and used for determining the vapor pressure of rubidium and cesium. This method measures tae critical pressure directly, as well as the vapor pressure st lower temperatures. (4 tables, 6 figures, 26 references) (auth)

Jerez, W.R.; Bhise, V.S.; Das Gupta, S.; Bonilla, C.F.

1973-01-01T23:59:59.000Z

392

Atmospheric Precorrected Differential Absorption technique to retrieve columnar water vapor  

Science Conference Proceedings (OSTI)

Differential absorption techniques are suitable to retrieve the total column water vapor contents from imaging spectroscopy data. A technique called Atmospheric Precorrected Differential Absorption (APDA) is derived directly from simplified radiative transfer equations. It combines a partial atmospheric correction with a differential absorption technique. The atmospheric path radiance term is iteratively corrected during the retrieval of water vapor. This improves the results especially over low background albedos. The error of the method for various ground reflectance spectra is below 7% for most of the spectra. The channel combinations for two test cases are then defined, using a quantitative procedure, which is based on MODTRAN simulations and the image itself. An error analysis indicates that the influence of aerosols and channel calibration is minimal. The APDA technique is then applied to two AVIRIS images acquired in 1991 and 1995. The accuracy of the measured water vapor columns is within a range of {+-}5% compared to ground truth radiosonde data.

Schlaepfer, D.; Itten, K.I. [Univ. of Zuerich (Switzerland). Dept. of Geography] [Univ. of Zuerich (Switzerland). Dept. of Geography; Borel, C.C. [Los Alamos National Lab., NM (United States)] [Los Alamos National Lab., NM (United States); Keller, J. [Paul Scherrer Inst., Villigen (Switzerland)] [Paul Scherrer Inst., Villigen (Switzerland)

1998-09-01T23:59:59.000Z

393

Interactions between Liquid-Wall Vapor and Edge Plasmas  

DOE Green Energy (OSTI)

The use of liquid walls for fusion reactors could help solve problems associated with material erosion from high plasma heat-loads and neutronic activation of structures. A key issue analyzed here is the influx of impurity ions to the core plasma from the vapor of liquid side-walls. Numerical 2D transport simulations are performed for a slab geometry which approximates the edge region of a reactor-size tokamak. Both lithium vapor (from Li or SnLi walls) and fluorine vapor (from Flibe walls) are considered for hydrogen edge-plasmas in the high- and low-recycling regimes. It is found that the minimum influx is from lithium with a low-recycling hydrogen plasma, and the maximum influx occurs for fluorine with a high-recycling hydrogen plasma.

Rognlien, T D; Rensink, M E

2000-05-25T23:59:59.000Z

394

Intermediate Vapor Expansion Distillation and Nested Enrichment Cascade Distillation  

E-Print Network (OSTI)

Although it is known that incorporating an intermediate reboiler or reflux condenser in a distillation column will improve column efficiency by 15 to 100%, there has been little use of this technique to date." Intermediate vapor compression heat pumping was recently introduced as one practical means of achieving this benefit. Introduced in this paper are two new means having added advantages over compression: intermediate vapor expansion heat pumping, and nested enrichment cascades. In both cases the efficiency advantage is obtained without requiring import of shaft work. With intermediate vapor expansion, the expander is more efficient and less costly than the compressor which achieves comparable improvement in distillation efficiency. With the "nested enrichment" technique, the increased efficiency is obtained without requiring either compressors or expanders.

Erickson, D. C.

1986-06-01T23:59:59.000Z

395

It's Elemental - Isotopes of the Element Sodium  

NLE Websites -- All DOE Office Websites (Extended Search)

Neon Neon Previous Element (Neon) The Periodic Table of Elements Next Element (Magnesium) Magnesium Isotopes of the Element Sodium [Click for Main Data] Most of the isotope data on this site has been obtained from the National Nuclear Data Center. Please visit their site for more information. Naturally Occurring Isotopes Mass Number Natural Abundance Half-life 23 100% STABLE Known Isotopes Mass Number Half-life Decay Mode Branching Percentage 18 1.3×10-21 seconds Proton Emission 100.00% 19 < 40 nanoseconds Proton Emission No Data Available 20 447.9 milliseconds Electron Capture with delayed Alpha Decay 20.05% Electron Capture 100.00% 21 22.49 seconds Electron Capture 100.00% 22 2.6027 years Electron Capture 100.00% 23 STABLE - - 24 14.997 hours Beta-minus Decay 100.00%

396

Low temperature sodium-beta battery  

SciTech Connect

A battery that will operate at ambient temperature or lower includes an enclosure, a current collector within the enclosure, an anode that will operate at ambient temperature or lower within the enclosure, a cathode that will operate at ambient temperature or lower within the enclosure, and a separator and electrolyte within the enclosure between the anode and the cathode. The anode is a sodium eutectic anode that will operate at ambient temperature or lower and is made of a material that is in a liquid state at ambient temperature or lower. The cathode is a low melting ion liquid cathode that will operate at ambient temperature or lower and is made of a material that is in a liquid state at ambient temperature or lower.

Farmer, Joseph C

2013-11-19T23:59:59.000Z

397

Update; Sodium advanced fast reactor (SAFR) concept  

SciTech Connect

This paper reports on the sodium advanced fast reactor (SAFR) concept developed by the team of Rockwell International, Combustion Engineering, and Bechtel during the 3-year period extending from January 1985 to December 1987 as one element in the U.S. Department of Energy's Advanced Liquid Metal Reactor Program. In January 1988, the team was expanded to include Duke Engineering and Services, Inc., and the concept development was extended under DOE's Program for Improvement in Advanced Modular LMR Design. The SAFR plant concept employs a 450-MWe pool-type liquid metal cooled reactor as its basic module. The reactor assembly module is a standardized shop-fabricated unit that can be shipped to the plant site by barge for installation. Shop fabrication minimizes nuclear-grade field fabrication and reduces the plant construction schedule. Reactor modules can be used individually or in multiples at a given site to supply the needed generating capacity.

Oldenkamp, R.D.; Brunings, J.E. (Rockwell International Corp., Canoga Park, CA (USA)); Guenther, E. (Combustion Engineering, Windsor, CT (US)); Hren, R. (Bechtel National Inc., San Francisco, CA (US))

1988-01-01T23:59:59.000Z

398

FUEL PROGRAMMING FOR SODIUM GRAPHITE REACTORS  

SciTech Connect

The effect of fuel programming, i.e., the scheme used for changing fuel in a core, on the reactivity and specific power of a sodium graphite reactor is discussed Fuel programs considered Include replacing fuel a core-load at a time or a radial zone at a time, replacing fuel to manutain the same average exposure of fuel elements throughout the core, and replacing and transferring fuel elements to maintain more highly exposed fuel in the center or at the periphery of the core. Flux and criticality calculations show the degree of power flattening and the concurrent decrease in effective multiplication which results from maintaining more exposed fuel toward the core center. Corverse effects are shown for the case of maintaining more exposed fuel near the core periphery. The excess reactivity which must be controlled in the various programs is considered. Illustrative schedules for implementing each of these programs in an SGR are presented. (auth)

Connolly, T.J.

1959-10-15T23:59:59.000Z

399

Liquid-phase compositions from vapor-phase analyses  

SciTech Connect

Arsenic normally is not considered to be a contaminant. However, because arsenic was found in many cylinders of UF{sub 6}, including in corrosion products, a study was performed of the distribution of the two arsenic fluorides, AsF{sub 3} and AsF{sub 5}, between liquid and vapor phases. The results of the study pertain to condensation or vaporization of liquid UF{sub 6}. This study includes use of various experimental data plus many extrapolations necessitated by the meagerness of the experimental data. The results of this study provide additional support for the vapor-liquid equilibrium model of J.M. Prausnitz and his coworkers as a means of describing the distribution of various impurities between vapor and liquid phases of UF{sub 6}. Thus, it is concluded that AsF{sub 3} will tend to concentrate in the liquid phase but that the concentration of AsF{sub 5} in the vapor phase will exceed its liquid-phase concentration by a factor of about 7.5, which is in agreement with experimental data. Because the weight of the liquid phase in a condensation operation may be in the range of thousands of times that of the vapor phase, most of any AsF{sub 5} will be in the liquid phase in spite of this separation factor of 7.5. It may also be concluded that any arsenic fluorides fed into a uranium isotope separation plant will either travel with other low-molecular-weight gases or react with materials present in the plant. 25 refs., 3 figs., 6 tabs.

Davis, W. Jr. (Oak Ridge Gaseous Diffusion Plant, TN (USA)); Cochran, H.D. (Oak Ridge National Lab., TN (USA))

1990-02-01T23:59:59.000Z

400

Data:9ed8f281-7c9a-4f4f-a8f0-1fabf477296b | Open Energy Information  

Open Energy Info (EERE)

-7c9a-4f4f-a8f0-1fabf477296b -7c9a-4f4f-a8f0-1fabf477296b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-250 W SV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Data:506e7491-7a10-4e8b-bf1b-8e28fdee71d1 | Open Energy Information  

Open Energy Info (EERE)

91-7a10-4e8b-bf1b-8e28fdee71d1 91-7a10-4e8b-bf1b-8e28fdee71d1 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Continental Divide El Coop Inc Effective date: End date if known: Rate name: STREET LIGHTING (Public)-175 W MV* Sector: Lighting Description: * As of Dec. 31, 1999, new mercury vapor fixtures are no longer available. The rates and adjustments set forth below are based on average billing period consumption, as follows: 100-watt fixture:47 kWh/fixture 175-watt fixture:76 kWh/fixture 250-watt fixture:110 kWh/fixture 400-watt mercury vapor fixture:166 kWh/fixture 400-watt sodium vapor fixture:176 kWh/fixture

402

Vapor sampling of the headspace of radioactive waste storage tanks  

DOE Green Energy (OSTI)

This paper recants the history of vapor sampling in the headspaces of radioactive waste storage tanks at Hanford. The first two tanks to receive extensive vapor pressure sampling were Tanks 241-SY-101 and 241-C-103. At various times, a gas chromatography, on-line mass spectrometer, solid state hydrogen monitor, FTIR, and radio acoustic ammonia monitor have been installed. The head space gas sampling activities will continue for the next few years. The current goal is to sample the headspace for all the tanks. Some tank headspaces will be sampled several times to see the data vary with time. Other tanks will have continuous monitors installed to provide additional data.

Reynolds, D.A., Westinghouse Hanford

1996-05-22T23:59:59.000Z

403

Independent Oversight Assessment, Idaho Cleanup Project Sodium Bearing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Idaho Cleanup Project Sodium Idaho Cleanup Project Sodium Bearing Waste Treatment Project - November 2012 Independent Oversight Assessment, Idaho Cleanup Project Sodium Bearing Waste Treatment Project - November 2012 November 2012 Assessment of Nuclear Safety Culture at the Idaho Cleanup Project Sodium Bearing Waste Treatment Project The U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), conducted an independent assessment of nuclear safety culture at the DOE Sodium Bearing Waste Treatment Project (SBWTP). The primary objective of the evaluation was to provide information regarding the status of the safety culture at SBWTP. The data collection phase of the assessment occurred in April and May 2012. SBWTP is one of DOE's largest nuclear

404

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sodium Bearing Waste Treatment Sodium Bearing Waste Treatment Project - Federal - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Federal - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Federal Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) DOE (Federal) Operational Readiness Review (D-ORR). The review was performed by the HSS Office of Safety and Emergency Management Evaluations and was intended to assess the effectiveness of the CORR process as implemented for

405

EIS-0287: Notice of Preferred Sodium Bearing Waste Treatment Technology |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Preferred Sodium Bearing Waste Treatment Preferred Sodium Bearing Waste Treatment Technology EIS-0287: Notice of Preferred Sodium Bearing Waste Treatment Technology Idaho High-Level Waste (HLW) and Facilities Disposition In October 2002, the U.S. Department of Energy (DOE or the Department) issued the Final Idaho High-Level Waste (HLW) and Facilities Disposition Environmental Impact Statement (DOE/EIS-0287 (Final EIS)). The Final EIS contains an evaluation of reasonable alternatives for the management of mixed transuranic waste/sodium bearing waste (SBW),1 mixed HLW calcine, and associated low-level waste (LLW), as well as disposition alternatives for HLW facilities when their missions are completed. DOE/EIS-0287, Notice of Preferred Sodium Bearing Waste Treatment Technology, Office of Environmental Management, Idaho, 70 FR 44598 (August

406

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sodium Bearing Waste Treatment Sodium Bearing Waste Treatment Project - Contractor - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Contractor - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Contractor Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) contractor Operational Readiness Review (C-ORR). The review was conducted at the Idaho Site from February 27 to March 6, 2012. This report discusses the background, scope, results, and conclusions of the review, as well as

407

Solid-state sodium batteries using polymer electrolytes and sodium intercalation electrode materials  

DOE Green Energy (OSTI)

Solid-state sodium cells using polymer electrolytes (polyethylene oxide mixed with sodium trifluoromethanesulfonate: PEO{sub n}NaCF{sub 3}SO{sub 3}) and sodium cobalt oxide positive electrodes are characterized in terms of discharge and charge characteristics, rate capability, cycle life, and energy and power densities. The P2 phase Na{sub x}CoO{sub 2} can reversibly intercalate sodium in the range of x = 0.3 to 0.9, giving a theoretical specific energy of 440 Wh/kg and energy density of 1,600 Wh/l. Over one hundred cycles to 60% depth of discharge have been obtained at 0.5 mA/cm{sup 2}. Experiments show that the electrolyte/Na interface is stable and is not the limiting factor to cell cycle life. Na{sub 0.7}CoO{sub 2} composite electrodes containing various amounts of carbon black additive are investigated. The transport properties of polymer electrolytes are the critical factors for performance. These properties (the ionic conductivity, salt diffusion coefficient, and ion transference number) are measured for the PEO{sub n}NaCF{sub 3}SO{sub 3} system over a wide range of concentrations at 85 C. All the three transport properties are very salt-concentration dependent. The ionic conductivity exhibits a maximum at about n = 20. The transference number, diffusion coefficient, and thermodynamic factor all vary with salt concentration in a similar fashion, decreasing as the concentration increases, except for a local maximum. These results verify that polymer electrolytes cannot be treated as ideal solutions. The measured transport-property values are used to analyze and optimize the electrolytes by computer simulation and also cell testing. Salt precipitation is believed to be the rate limiting process for cells using highly concentrated solutions, as a result of lower values of these properties, while salt depletion is the limiting factor when a dilute solution is used.

Ma, Y. [Univ. of California, Berkeley, CA (United States). Dept. of Materials Science and Mineral Engineering]|[Lawrence Berkeley National Lab., CA (United States). Materials Sciences Div.

1996-08-01T23:59:59.000Z

408

Decommissioning of Experimental Breeder Reactor - II Complex, Post Sodium Draining  

Science Conference Proceedings (OSTI)

The Experimental Breeder Reactor - II (EBR-II) was shutdown in September 1994 as mandated by the United States Department of Energy. This sodium-cooled reactor had been in service since 1964. The bulk sodium was drained from the primary and secondary systems and processed. Residual sodium remaining in the systems after draining was converted into sodium bicarbonate using humid carbon dioxide. This technique was tested at Argonne National Laboratory in Illinois under controlled conditions, then demonstrated on a larger scale by treating residual sodium within the EBR-II secondary cooling system, followed by the primary tank. This process, terminated in 2002, was used to place a layer of sodium bicarbonate over all exposed surfaces of sodium. Treatment of the remaining EBR-II sodium is governed by the Resource Conservation and Recovery Act (RCRA). The Idaho Department of Environmental Quality issued a RCRA Operating Permit in 2002, mandating that all hazardous materials be removed from EBR-II within a 10 year period, with the ability to extend the permit and treatment period for another 10 years. A preliminary plan has been formulated to remove the remaining sodium and NaK from the primary and secondary systems using moist carbon dioxide, steam and nitrogen, and a water flush. The moist carbon dioxide treatment was resumed in May 2004. As of August 2005, approximately 60% of the residual sodium within the EBR-II primary tank had been treated. This process will continue through the end of 2005, when it is forecast that the process will become increasingly ineffective. At that time, subsequent treatment processes will be planned and initiated. It should be noted that the processes and anticipated costs associated with these processes are preliminary. Detailed engineering has not been performed, and approval for these methods has not been obtained from the regulator or the sponsors.

J. A. (Bart) Michelbacher; S. Paul Henslee; Collin J. Knight; Steven R. sherman

2005-09-01T23:59:59.000Z

409

Effect of higher water vapor content on TBC performance  

Science Conference Proceedings (OSTI)

Coal gasification, or IGCC (integrated gasification combined cycle), is one pathway toward cleaner use of coal for power generation with lower emissions. However, when coal-derived synthesis gas (i.e., syngas) is burned in turbines designed for natural gas, turbine manufacturers recommend 'derating,' or lowering the maximum temperature, which lowers the efficiency of the turbine, making electricity from IGCC more expensive. One possible reason for the derating is the higher water vapor contents in the exhaust gas. Water vapor has a detrimental effect on many oxidation-resistant high-temperature materials. In a turbine hot section, Ni-base superalloys are coated with a thermal barrier coating (TBC) allowing the gas temperature to be higher than the superalloy solidus temperature. TBCs have a low thermal conductivity ceramic top coating (typically Y{sub 2}O{sub 3}-stabilized ZrO{sub 2}, or YSZ) and an oxidation-resistant metallic bond coating. For land-based gas turbines, the industry standard is air plasma sprayed (APS) YSZ and high velocity oxygen fuel (HVOF) sprayed NiCoCrAlY bond coatings. To investigate the role of higher water vapor content on TBC performance and possible mitigation strategies, furnace cycling experiments were conducted in dry O{sub 2} and air with 10% (typical with natural gas or jet fuel) or 50 vol% water vapor. Cycle frequency and temperature were accelerated to one hour at 1100 C (with 10 minute cooling to {approx}30 C between each thermal cycle) to induce early failures in coatings that are expected to operate for several years with a metal temperature of {approx}900 C. Coupons (16 mm diameter x 2 mm thick) of commercial second-generation single crystal superalloy CMSX4 were HVOF coated on both sides with {approx}125 {micro}m of Ni-22wt%Co-17Cr-12Al either with 0.7Y or 0.7Y-0.3Hf-0.4Si. One side was then coated with 190-240 {micro}m of APS YSZ. Coatings were cycled until the YSZ top coating spalled. Figure 2 shows the results of the initial phase of experiments. Compared to dry O{sub 2}, the addition of 10% water vapor decreased the lifetime of MCrAlY by {approx}30% for the conventional CMSX4 substrates. Higher average lifetimes were observed with Hf in the bond coating, but a similar decrease in lifetime was observed when water vapor was added. The addition of Y and La to the superalloy substrate did not change the YSZ lifetime with 10% water vapor. However, increasing water vapor content from 10 to 50% did not further decrease the lifetime of either bond coating with the doped superalloy substrate. Thus, these results suggest that higher water vapor contents cannot explain the derating of syngas-fired turbines, and other factors such as sulfur and ash from imperfect syngas cleanup (or upset conditions) need to be explored. Researchers continue to study effects of water vapor on thermally grown alumina scale adhesion and growth rate, and are looking for bond coating compositions more resistant to oxidation in the presence of water vapor.

Pint, Bruce A [ORNL; Haynes, James A [ORNL

2012-01-01T23:59:59.000Z

410

Ion Recognition Approach to Volume Reduction of Alkaline Tank Waste by Separation and Recycle of Sodium Hydroxide and Sodium Nitrate  

SciTech Connect

This research was intended to provide the scientific foundation upon which the feasibility of liquid-liquid extraction chemistry for bulk reduction of the volume of high-activity tank waste can be evaluated. Primary focus has been on sodium hydroxide separation, with potential Hanford application. Value in sodium hydroxide separation can potentially be found in alternative flowsheets for treatment and disposal of low-activity salt waste. Additional value can be expected in recycle of sodium hydroxide for use in waste retrieval and sludge washing, whereupon additions of fresh sodium hydroxide to the waste can be avoided. Potential savings are large both because of the huge cost of vitrification of the low-activity waste stream and because volume reduction of high-activity wastes could obviate construction of costly new tanks. Toward these ends, the conceptual development begun in the original proposal was extended with the formulation of eight fundamental approaches that could be undertaken for extraction of sodium hydroxide.

Bruce A. Moyer; Alan P. Marchand; Peter V. Bonnesen; Jeffrey C. Bryan; Tamara J. Haverlock

2004-06-08T23:59:59.000Z

411

The Atomic Vapor Laser Isotope Separation Program. [Atomic Vapor Laser Isotope Separation (AVLIS) Program  

SciTech Connect

This report provides the finding and recommendations on the audit of the Atomic Vapor Laser Isotope Separation (AVLIS) program. The status of the program was assessed to determine whether the Department was achieving objectives stated in its January 1990 Plan for the Demonstration, Transition and Deployment of AVLIS Technology. Through Fiscal Year 1991, the Department had spent about $1.1 billion to develop AVLIS technology. The January 1990 plan provided for AVLIS to be far enough along by September to enable the Department to make a determination of the technical and economic feasibility of deployment. However, the milestones needed to support that determination were not met. An estimated $550 million would be needed to complete AVLIS engineering development and related testing prior to deployment. The earliest possible deployment date has slipped to beyond the year 2000. It is recommended that the Department reassess the requirement for AVLIS in light of program delays and changes that have taken place in the enrichment market since January 1990. Following the reassessment, a decision should be made to either fully support and promote the actions needed to complete AVLIS development or discontinue support for the program entirely. Management's position is that the Department will successfully complete the AVLIS technology demonstration and that the program should continue until it can be transferred to a Government corporation. Although the auditors recognize that AVLIS may be transferred, there are enough technical and financial uncertainties that a thorough assessment is warranted.

Not Available

1992-11-09T23:59:59.000Z

412

Vapor-Liquid Partitioning of Sulfuric Acid and Ammonium Sulfate  

Science Conference Proceedings (OSTI)

The quality of water and steam is central to ensuring power plant component availability and reliability. A key part of developing operating cycle chemistry guidelines is an understanding of the impurity distribution between water and steam. This study focused on the partitioning of sulfuric acid and ammonium bisulfate between the liquid and vapor phases.

1999-03-31T23:59:59.000Z

413

Computation of Infrared Cooling Rates in the Water Vapor Bands  

Science Conference Proceedings (OSTI)

A fast but accurate method for calculating the infrared radiative terms due to water vapor has been developed. It makes use of the behavior in the far wings of absorption lines to scale transmission along an inhomogencous path to an equivalent ...

Ming Dah Chou; Albert Arking

1980-04-01T23:59:59.000Z

414

Probing Hurricanes with Stable Isotopes of Rain and Water Vapor  

Science Conference Proceedings (OSTI)

Rain and water vapor were collected during flights in Hurricanes Olivia (1994), Opal (1995), Marilyn (1995), and Hortense (1995) and analyzed for their stable isotopic concentrations, or ratios, H218O:H2O and HDO:H2O. The spatial patterns and ...

Stanley Gedzelman; James Lawrence; John Gamache; Michael Black; Edward Hindman; Robert Black; Jason Dunion; Hugh Willoughby; Xiaoping Zhang

2003-06-01T23:59:59.000Z

415

City of Johnson City, Tennessee (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Johnson City City of Johnson City City of Place Tennessee Utility Id 9777 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png GENERAL POWER RATE - GSA 1 - 1PH (Rate 440) Commercial GENERAL POWER RATE - GSA 1 - 3PH (Rate 440) Commercial GENERAL POWER RATE - GSA 2 (Rate 550) Commercial GENERAL POWER RATE - GSA 3 (Rate 554) Commercial RS Residential Rate 556 Seasonal - Over 5,000 KW Commercial SECURITY LIGHTS 100 WATT SODIUM VAPOR Lighting SECURITY LIGHTS 250 WATT SODIUM VAPOR Lighting

416

Duncan Valley Elec Coop, Inc | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search Name Duncan Valley Elec Coop, Inc Place Arizona Utility Id 5438 Utility Location Yes Ownership C NERC Location WECC NERC WECC Yes ISO Other Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Schedule LS - Private Area Lighting Service(100 and 175 watt mercury and sodium vapor) Lighting Schedule LS - Private Area Lighting Service with pole(100 and 175 watt mercury and sodium vapor) Lighting Schedule PSHL - Public Street & Highway Lighting - 100W Lamp Lighting Schedule PSHL - Public Street & Highway Lighting - 175W Lamp Lighting

417

Experimental investigations on sodium plugging in narrow flow channels.  

SciTech Connect

A series of experiments was performed to investigate the potential for plugging of narrow flow channels of sodium by impurities (e.g., oxides). In the first phase of the experiments, clean sodium was circulated through the test sections simulating flow channels in a compact diffusion-bonded heat exchanger such as a printed circuit heat exchanger. The primary objective was to see if small channels whose cross sections are semicircles of 2, 4, and 6 mm in diameter are usable in liquid sodium applications where sodium purity is carefully controlled. It was concluded that the 2-mm channels, the smallest of the three, could be used in clean sodium systems at temperatures even as low as 100 to 110 C without plugging. In the second phase, sodium oxide was added to the loop, and the oxygen concentration in the liquid sodium was controlled by means of varying the cold-trap temperature. Intentional plugging was induced by creating a cold spot in the test sections, and the subsequent plugging behavior was observed. It was found that plugging in the 2-mm test section was initiated by lowering the cold spot temperature below the cold-trap temperature by 10 to 30 C. Unplugging of the plugged channels was accomplished by heating the affected test section.

Momozaki, Y.; Cho, D. H.; Sienicki, J. J.; Moisseytsev, A.; Nuclear Engineering Division

2010-08-01T23:59:59.000Z

418

Observation of Water Vapor Greenhouse Absorption over the Gulf of Mexico Using Aircraft and Satellite Data  

Science Conference Proceedings (OSTI)

Through its interaction with radiation, water vapor provides an important link between the ocean and atmosphere. One way this occurs is through the greenhouse effect; observations of water vapor greenhouse absorption in the Gulf of Mexico during ...

David Marsden; Francisco P. J. Valero

2004-03-01T23:59:59.000Z

419

Investigation of Turbulent Processes in the Lower Troposphere with Water Vapor DIAL and RadarRASS  

Science Conference Proceedings (OSTI)

High-resolution water vapor and wind measurements in the lower troposphere within the scope of the Baltic Sea Experiment (BALTEX) are presented. The measurements were performed during a field campaign with a new water vapor differential ...

V. Wulfmeyer

1999-04-01T23:59:59.000Z

420

Method and apparatus to measure vapor pressure in a flow system  

DOE Patents (OSTI)

The present invention is directed to a method for determining, by a condensation method, the vapor pressure of a material with a known vapor pressure versus temperature characteristic, in a flow system particularly in a mercury isotope enrichment process.

Grossman, Mark W. (Belmont, MA); Biblarz, Oscar (Swampscott, MA)

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Influence of a Tropical Island Mountain on Solar Radiation, Air Temperature and Vapor Pressure  

Science Conference Proceedings (OSTI)

Measured solar radiation, air temperature, and water vapor pressure at 17 stations on the northwest flank of Haleakala, Maui, Hawaii are compared with modeled clear day solar radiation and free atmosphere air temperature and water vapor pressure. ...

Dennis Nullet

1989-03-01T23:59:59.000Z

422

Modes and Mechanisms of Global Water Vapor Variability over the Twentieth Century  

Science Conference Proceedings (OSTI)

The modes and mechanisms of the annual water vapor variations over the twentieth century are investigated based on a newly developed twentieth-century atmospheric reanalysis product. It is found that the leading modes of global water vapor ...

Liping Zhang; Lixin Wu; Bolan Gan

2013-08-01T23:59:59.000Z

423

Water Vapor Transport and the Production of Precipitation in the Eastern Fertile Crescent  

Science Conference Proceedings (OSTI)

The study presented here attempts to quantify the significance of southerly water vapor fluxes on precipitation occurring in the eastern Fertile Crescent region. The water vapor fluxes were investigated at high temporal and spatial resolution by ...

J. P. Evans; R. B. Smith

2006-12-01T23:59:59.000Z

424

Automated Retrievals of Water Vapor and Aerosol Profiles from an Operational Raman Lidar  

Science Conference Proceedings (OSTI)

Automated routines have been developed to derive water vapor mixing ratio, relative humidity, aerosol extinction and backscatter coefficient, and linear depolarization profiles, as well as total precipitable water vapor and aerosol optical ...

D. D. Turner; R. A. Ferrare; L. A. Heilman Brasseur; W. F. Feltz; T. P. Tooman

2002-01-01T23:59:59.000Z

425

Tropical Water Vapor and Cloud Feedbacks in Climate Models: A Further Assessment Using Coupled Simulations  

Science Conference Proceedings (OSTI)

By comparing the response of clouds and water vapor to ENSO forcing in nature with that in Atmospheric Model Intercomparison Project (AMIP) simulations by some leading climate models, an earlier evaluation of tropical cloud and water vapor ...

De-Zheng Sun; Yongqiang Yu; Tao Zhang

2009-03-01T23:59:59.000Z

426

A Comparison of Water Vapor Measurements Made by Raman Lidar and Radiosondes  

Science Conference Proceedings (OSTI)

This paper examines the calibration characteristics of the NASA/GSFC Raman water vapor lidar during three field experiments that occurred between 1991 and 1993. The lidar water vapor profiles are calibrated using relative humidity profiles ...

R. A. Ferrare; S. H. Melfi; D. N. Whiteman; K. D. Evans; F. J. Schmidlin; D. O'C. Starr

1995-12-01T23:59:59.000Z

427

Heat transfer during film condensation of potassium vapor on a horizontal plate  

E-Print Network (OSTI)

The object of the investigation is to analyze the following two features of heat transfer during condensation of potassium vapor: a. Heat transfer during film condensation of a pure saturated potassium vapor on a horizontal ...

Meyrial, Paul M.

1968-01-01T23:59:59.000Z

428

Distributions of Liquid, Vapor, and Ice in an Orographic Cloud from Field Observations  

Science Conference Proceedings (OSTI)

The phase distribution of the water mass of a cold orographic cloud into vapor, liquid, and ice is calculated from measurements made from an instrumented aircraft. The vapor values are calculated from thermodynamic measurements, and the liquid is ...

Taneil Uttal; Robert M. Rauber; Lewis O. Grant

1988-04-01T23:59:59.000Z

429

Chemical vapor deposition thin films as biopassivation coatings and directly patternable dielectrics  

E-Print Network (OSTI)

Organosilicon thin films deposited by pulsed plasma-enhanced chemical vapor deposition (PPECVD) and hot-filament chemical vapor deposition (HFCVD) were investigated as potential biopassivation coatings for neural probes. ...

Pryce Lewis, Hilton G. (Hilton Gavin), 1973-

2001-01-01T23:59:59.000Z

430

Determination of concentration-dependent dispersion of propane in vapor extraction of heavy oil.  

E-Print Network (OSTI)

??Vapex (vapor extraction) is a solvent-based non-thermal in-situ heavy oil recovery process. In Vapex process, a vaporized hydrocarbon solvent is injected into an upper horizontal (more)

Abukhalifeh, Hadil

2010-01-01T23:59:59.000Z

431

Measurements of the Vapor Pressure of Supercooled Water Using Infrared Spectroscopy  

Science Conference Proceedings (OSTI)

Measurements are presented of the vapor pressure of supercooled water utilizing infrared spectroscopy, which enables unambiguous verification that the authors data correspond to the vapor pressure of liquid water, not a mixture of liquid water ...

Will Cantrell; Eli Ochshorn; Alexander Kostinski; Keith Bozin

2008-09-01T23:59:59.000Z

432

Molecular dynamics study of sodium using a model pseudopotential  

Science Conference Proceedings (OSTI)

The dynamics of sodium is investigated using the coulomb and Born-Mayer interaction augmented by a model pseudopotential to represent the electron interactions including screening, exchange, and correlation. The model parameters were previously determined and have been shown to accurately reproduce experimental equation-of-state, lattice vibration, and crystal phase properties of sodium in the harmonic limit. In this paper the equation-of-state and structural properties are examined in molecular dynamics calculations. The long range effects of the potential are included. Typically, each particle interacts with about 500 neighbors. The calculated equation of state of sodium in the hcp, bcc, and liquid structures is discussed.

Swanson, R.E.; Straub, G.K.; Holian, B.L.

1981-01-01T23:59:59.000Z

433

Sodium Bearing Waste Processing Alternatives Analysis  

SciTech Connect

A multidisciplinary team gathered to develop a BBWI recommendation to DOE-ID on the processing alternatives for the sodium bearing waste in the INTEC Tank Farm. Numerous alternatives were analyzed using a rigorous, systematic approach. The data gathered were evaluated through internal and external peer reviews for consistency and validity. Three alternatives were identified to be top performers: Risk-based Calcination, MACT to WIPP Calcination and Cesium Ion Exchange. A dual-path through early Conceptual design is recommended for MACT to WIPP Calcination and Cesium Ion Exchange since Risk-based Calcination does not require design. If calcination alternatives are not considered based on giving Type of Processing criteria significantly greater weight, the CsIX/TRUEX alternative follows CsIX in ranking. However, since CsIX/TRUEX shares common uncertainties with CsIX, reasonable backups, which follow in ranking, are the TRUEX and UNEX alternatives. Key uncertainties must be evaluated by the decision-makers to choose one final alternative. Those key uncertainties and a path forward for the technology roadmapping of these alternatives is provided.

Murphy, James Anthony; Palmer, Brent J; Perry, Keith Joseph

2003-12-01T23:59:59.000Z

434

Structure and Aqueous Solubility of Sodium Isosaccharinate  

SciTech Connect

It has been recently shown that isosaccharinic acid, C6H12O6 (ISA), and its derivative salts have a great potential for practical application in the area of nuclear waste treatment and disposal sites management. Several studies demonstrated the effect of ISA complexation on radionuclide solubility and sorptive properties, especially on actinides in (+4) oxidation state like Np(IV) and Th(IV). The presence of ISA and/or its derivatives strongly affects the migration of radionuclides by increasing their solubility in water by several orders of magnitude and Na-ISA has been proposed as a component of decontamination formulations for actinide-contaminated surfaces. Here we report the synthesis, crystal's structure and characterization (FTIR, TGA) of sodium isosaccharate, NaC6H11O6-H2O (Na-ISA). The structure has been solved by single crystal X-ray diffraction methods. The solubility of Na-ISA has been evaluated and compared to that of Ca-ISA based on the structural features of both compounds.

Bontchev, Ranko P.; Moore, Robert; Tucker, Mark; Holt, Kathleen

2004-03-29T23:59:59.000Z

435

Coupled hydrodynamic-structural analysis of an integral flowing sodium test loop in the TREAT reactor  

SciTech Connect

A hydrodynamic-structural response analysis of the Mark-IICB loop was performed for the TREAT (Transient Reactor Test Facility) test AX-1. Test AX-1 is intended to provide information concerning the potential for a vapor explosion in an advanced-fueled LMFBR. The test will be conducted in TREAT with unirradiated uranium-carbide fuel pins in the Mark-IICB integral flowing sodium loop. Our analysis addressed the ability of the experimental hardware to maintain its containment integrity during the reference accident postulated for the test. Based on a thermal-hydraulics analysis and assumptions for fuel-coolant interaction in the test section, a pressure pulse of 144 MPa maximum pressure and pulse width of 1.32 ms has been calculated as the reference accident. The response of the test loop to the pressure transient was obtained with the ICEPEL and STRAW codes. Modelling of the test section was completed with STRAW and the remainder of the loop was modelled by ICEPEL.

Zeuch, W.R.; A-Moneim, M.T.

1979-01-01T23:59:59.000Z

436

NMR monitoring of intracellular sodium in dog and rabbit kidney tubules  

SciTech Connect

{sup 23}Na-nuclear magnetic resonance (NMR) was used to monitor intra- and extracellular sodium in suspensions of dog cortical tubules, rabbit cortical tubules, and dog thick ascending limbs. The NMR visibility of the intracellular sodium was determined by comparing the NMR and flame photometry results and by redistributing the sodium ions between the intra- and extracellular compartments using the ionophore nystatin (influx) or sodium substitution for choline in the extracellular fluid (efflux). The intracellular sodium visibility was {approximately}30% for the total sodium and 58% for the transportable sodium. Addition of sodium to sodium-depleted homogenates of dog renal cortex also showed a loss of visibility. The values of the relaxation times T{sub 1} and T{sub 2} were determined but could not be correlated with the visibility measurements. The intracellular sodium concentration in dog cortical tubules incubated in optimal biochemical conditions was estimated at 51 mM was dependent on the extracellular sodium concentration.

Boulanger, Y.; Vinay, P.; Boulanger, M. (Universite de Montreal, Quebec (Canada))

1987-11-01T23:59:59.000Z

437

High efficiency vapor-fed AMTEC system for direct conversion. Appendices for final report  

DOE Green Energy (OSTI)

This report consists of four appendices for the final report. They are: Appendix A: 700 C Vapor-Fed AMTEC Cell Calculations; Appendix B: 700 C Vapor-Fed AMTEC Cell Parts Drawings; Appendix C: 800 C Vapor-Fed AMTEC Cell Calculations; and Appendix D: 800 C Wick-Pumped AMTEC Cell System Design.

Anderson, W.G.; Bland, J.J.

1997-05-23T23:59:59.000Z

438

ADVANCED ONCE-THROUGH STEAM GENERATOR FOR SODIUM APPLICATION  

SciTech Connect

Preliminary design calculations were performed for a once-through type steam generator and reheater for advanced sodium power plants in the 300-Mwe range. Parameters and performance data are presented. (D.L.C.)

Terpe, G.R.

1960-09-19T23:59:59.000Z

439

Internal structure, hygroscopic and reactive properties of mixed sodium  

NLE Websites -- All DOE Office Websites (Extended Search)

Internal structure, hygroscopic and Internal structure, hygroscopic and reactive properties of mixed sodium methanesulfonate-sodium chloride particles Internal structure, hygroscopic and reactive properties of mixed sodium methanesulfonate-sodium chloride particles Print Friday, 13 May 2011 00:00 Scientists recently combined experimental approaches and molecular dynamics modeling to gain new insights into the internal structure of sea salt particles and relate it to their fundamental chemical reactivity in the atmosphere. This research shows that surface enhancement or depletion of chemical components in marine particles can occur because of the difference in the chemical nature of the species. Because the atmospheric chemistry of the salt particles takes place at the gas-particle interface, understanding their complex surfaces provides new insights about their effect on the environment and climate change. Article Link.

440

Probabilistic transient analysis of fuel choices for sodium fast reactors  

E-Print Network (OSTI)

This thesis presents the implications of using a risk-informed licensing framework to inform the design of Sodium Fast Reactors. NUREG-1860, more commonly known as the Technology Neutral Framework (TNF), is a risk-informed ...

Denman, Matthew R

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

United States, France and Japan Increase Cooperation on Sodium...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

on Sodium-Cooled Fast Reactor Prototypes February 1, 2008 - 11:13am Addthis WASHINGTON, DC -The U.S Department of Energy (DOE), the French Atomic Energy Commission (CEA) and...

442

Probabilistic transient analysis of fuel choices for sodium fast reactors.  

E-Print Network (OSTI)

??This thesis presents the implications of using a risk-informed licensing framework to inform the design of Sodium Fast Reactors. NUREG-1860, more commonly known as the (more)

Denman, Matthew R

2011-01-01T23:59:59.000Z

443

Reactor protection system design alternatives for sodium fast reactors  

E-Print Network (OSTI)

Historically, unprotected transients have been viewed as design basis events that can significantly challenge sodium-cooled fast reactors. The perceived potential consequences of a severe unprotected transient in a ...

DeWitte, Jacob D. (Jacob Dominic)

2011-01-01T23:59:59.000Z

444

Loop simulation capability for sodium-cooled systems  

E-Print Network (OSTI)

A one-dimensional loop simulation capability has been implemented in the thermal-hydraulic analysis code, THERMIT-4E. This code had been used to simulate and investigate flow in test sections of experimental sodium loops ...

Adekugbe, Oluwole A.

1984-01-01T23:59:59.000Z

445

ESS 2012 Peer Review - Sodium-based Battery Development - Dave...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nuclear Security Administration under contract DE-AC04-94AL85000. Sodium-based Battery Development A Family of Batteries for Large Scale Energy Storage D. Ingersoll, C....

446

Wall pressure exerted by hydrogenation of sodium aluminum hydride.  

DOE Green Energy (OSTI)

Wall pressure exerted by the bulk expansion of a sodium aluminum hydride bed was measured as a function of hydrogen content. A custom apparatus was designed and loaded with sodium alanates at densities of 1.0, 1.1, and 1.16 g/cc. Four complete cycles were performed to identify variations in measured pressure. Results indicated poor correlation between exerted pressure and hydrogen capacity of the sodium alanate beds. Mechanical pressure due to the hydrogenation of sodium alanates does not influence full-scale system designs as it falls within common design factors of safety. Gas pressure gradients within the porous solid were identified and may limit reaction rates, especially for high aspect ratio beds.

Perras, Yon E.; Dedrick, Daniel E.; Zimmerman, Mark D.

2009-06-01T23:59:59.000Z

447

SODIUM-HEATED STEAM GENERATOR DEVELOPMENT. Interim Status Report  

SciTech Connect

Design and development of a once -through sodiumheated steam generator are discussed. Research proposals are discussed for evaluating: carbon transfer and mass transfer effects in the steam generator, effect on heat transfer and two- phase flow of coiling tubes, corrosion of Croloy 21/4 in products of sodium-water reactions, procedure for welding tube to back side of the tube sheet, radiographic inspection of back side tube welds, and chemical simulation of sodium environment for leak testing. (N.W.R.)

1964-01-22T23:59:59.000Z

448

High temperature sodium testing of the CRBR prototype primary pump  

Science Conference Proceedings (OSTI)

Qualification testing in sodium of the CRBR primary pump was conducted through 1982. This paper presents an overview of the test program, a description of the Sodium Pump Test Facility (largest of its kind in the world), a brief description of the test article and summary overview of results. Of special interest were the high temperature gas convection tests and the extensive flow/speed control (dynamic) tests. Special innovative test methods were employed to investigate these phenomena.

Tessier, M.J.; Grimaldi, J.L.

1983-01-01T23:59:59.000Z

449

Alignment and operability analysis of a vertical sodium pump  

SciTech Connect

With the objective of identifying important alignment features of pumps such as FFTF, HALLAM, EBR II, PNC, PHENIX, and CRBR, alignment of the vertical sodium pump for the Clinch River Breeder Reactor Plant (CRBRP) is investigated. The CRBRP pump includes a flexibly coupled pump shaft and motor shaft, two oil-film tilting-pad hydrodynamic radial bearings in the motor plus a vertical thrust bearing, and two sodium hydrostatic bearings straddling the double-suction centrifugal impeller in the pump.

Gupta, V.K.; Fair, C.E.

1981-01-01T23:59:59.000Z

450

Hydrogen storage in sodium aluminum hydride.  

DOE Green Energy (OSTI)

Sodium aluminum hydride, NaAlH{sub 4}, has been studied for use as a hydrogen storage material. The effect of Ti, as a few mol. % dopant in the system to increase kinetics of hydrogen sorption, is studied with respect to changes in lattice structure of the crystal. No Ti substitution is found in the crystal lattice. Electronic structure calculations indicate that the NaAlH{sub 4} and Na{sub 3}AlH{sub 6} structures are complex-ionic hydrides with Na{sup +} cations and AlH{sub 4}{sup -} and AlH{sub 6}{sup 3-} anions, respectively. Compound formation studies indicate the primary Ti-compound formed when doping the material at 33 at. % is TiAl{sub 3} , and likely Ti-Al compounds at lower doping rates. A general study of sorption kinetics of NaAlH{sub 4}, when doped with a variety of Ti-halide compounds, indicates a uniform response with the kinetics similar for all dopants. NMR multiple quantum studies of solution-doped samples indicate solvent interaction with the doped alanate. Raman spectroscopy was used to study the lattice dynamics of NaAlH{sub 4}, and illustrated the molecular ionic nature of the lattice as a separation of vibrational modes between the AlH{sub 4}{sup -} anion-modes and lattice-modes. In-situ Raman measurements indicate a stable AlH{sub 4}{sup -} anion that is stable at the melting temperature of NaAlH{sub 4}, indicating that Ti-dopants must affect the Al-H bond strength.

Ozolins, Vidvuds; Herberg, J.L. (Lawrence Livermore National Laboratories, Livermore, CA); McCarty, Kevin F.; Maxwell, Robert S. (Lawrence Livermore National Laboratories, Livermore, CA); Stumpf, Roland Rudolph; Majzoub, Eric H.

2005-11-01T23:59:59.000Z

451

Advanced sodium fast reactor accident source terms : research needs.  

Science Conference Proceedings (OSTI)

An expert opinion elicitation has been used to evaluate phenomena that could affect releases of radionuclides during accidents at sodium-cooled fast reactors. The intent was to identify research needed to develop a mechanistic model of radionuclide release for licensing and risk assessment purposes. Experts from the USA, France, the European Union, and Japan identified phenomena that could affect the release of radionuclides under hypothesized accident conditions. They qualitatively evaluated the importance of these phenomena and the need for additional experimental research. The experts identified seven phenomena that are of high importance and have a high need for additional experimental research: High temperature release of radionuclides from fuel during an energetic eventEnergetic interactions between molten reactor fuel and sodium coolant and associated transfer of radionuclides from the fuel to the coolantEntrainment of fuel and sodium bond material during the depressurization of a fuel rod with breached claddingRates of radionuclide leaching from fuel by liquid sodiumSurface enrichment of sodium pools by dissolved and suspended radionuclidesThermal decomposition of sodium iodide in the containment atmosphereReactions of iodine species in the containment to form volatile organic iodides. Other issues of high importance were identified that might merit further research as development of the mechanistic model of radionuclide release progressed.

Powers, Dana Auburn; Clement, Bernard [IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France] IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France; Denning, Richard [Ohio State University, Columbus, OH] Ohio State University, Columbus, OH; Ohno, Shuji [Japan Atomic Energy Agency, Ibaraki, Japan] Japan Atomic Energy Agency, Ibaraki, Japan; Zeyen, Roland [Institute for Energy Petten, Saint-Paul-lez-Durance, France] Institute for Energy Petten, Saint-Paul-lez-Durance, France

2010-09-01T23:59:59.000Z

452

Advanced sodium fast reactor accident source terms : research needs.  

SciTech Connect

An expert opinion elicitation has been used to evaluate phenomena that could affect releases of radionuclides during accidents at sodium-cooled fast reactors. The intent was to identify research needed to develop a mechanistic model of radionuclide release for licensing and risk assessment purposes. Experts from the USA, France, the European Union, and Japan identified phenomena that could affect the release of radionuclides under hypothesized accident conditions. They qualitatively evaluated the importance of these phenomena and the need for additional experimental research. The experts identified seven phenomena that are of high importance and have a high need for additional experimental research: High temperature release of radionuclides from fuel during an energetic eventEnergetic interactions between molten reactor fuel and sodium coolant and associated transfer of radionuclides from the fuel to the coolantEntrainment of fuel and sodium bond material during the depressurization of a fuel rod with breached claddingRates of radionuclide leaching from fuel by liquid sodiumSurface enrichment of sodium pools by dissolved and suspended radionuclidesThermal decomposition of sodium iodide in the containment atmosphereReactions of iodine species in the containment to form volatile organic iodides. Other issues of high importance were identified that might merit further research as development of the mechanistic model of radionuclide release progressed.

Powers, Dana Auburn; Clement, Bernard [IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France] IRSN/DPAM.SEMIC Bt 702, Saint-Paul-lez-Durance, France; Denning, Richard [Ohio State University, Columbus, OH] Ohio State University, Columbus, OH; Ohno, Shuji [Japan Atomic Energy Agency, Ibaraki, Japan] Japan Atomic Energy Agency, Ibaraki, Japan; Zeyen, Roland [Institute for Energy Petten, Saint-Paul-lez-Durance, France] Institute for Energy Petten, Saint-Paul-lez-Durance, France

2010-09-01T23:59:59.000Z

453

Method for the generation of variable density metal vapors which bypasses the liquidus phase  

DOE Patents (OSTI)

The present invention provides a method for producing a metal vapor that includes the steps of combining a metal and graphite in a vessel to form a mixture; heating the mixture to a first temperature in an argon gas atmosphere to form a metal carbide; maintaining the first temperature for a period of time; heating the metal carbide to a second temperature to form a metal vapor; withdrawing the metal vapor and the argon gas from the vessel; and separating the metal vapor from the argon gas. Metal vapors made using this method can be used to produce uniform powders of the metal oxide that have narrow size distribution and high purity.

Kunnmann, Walter (Stony Brook, NY); Larese, John Z. (Rocky Point, NY)

2001-01-01T23:59:59.000Z

454

Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) | Open Energy  

Open Energy Info (EERE)

Mokapu Penninsula Area (Thomas, 1986) Mokapu Penninsula Area (Thomas, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Mercury Vapor At Mokapu Penninsula Area (Thomas, 1986) Exploration Activity Details Location Mokapu Penninsula Area Exploration Technique Mercury Vapor Activity Date Usefulness not useful DOE-funding Unknown Notes The high degree of cultural activity (e.g. residential areas, streets, jet runways, etc.) on Mokapu both limited the extent of the soil geochemical surveys performed and rendered their interpretation much more difficult. Soil mercury concentrations and radon emanometry data on the peninsula showed a few localized high values (Figs 13, 14), but no consistent correlation between the anomalous zones and geologic features could be

455

Catalytic hydrogenation process and apparatus with improved vapor liquid separation  

DOE Patents (OSTI)

A continuous hydrogenation process and apparatus wherein liquids are contacted with hydrogen in an ebullated catalyst reaction zone with the liquids and gas flowing vertically upwardly through that zone into a second zone substantially free of catalyst particles and wherein the liquid and gases are directed against an upwardly inclining surface through which vertical conduits are placed having inlet ends at different levels in the liquid and having outlet ends at different levels above the inclined surface, such that vapor-rich liquid is collected and discharged through conduits terminating at a higher level above the inclined surface than the vapor-poor liquid which is collected and discharged at a level lower than the inclined surface.

Chervenak, Michael C. (Pennington, NJ); Comolli, Alfred G. (Trenton, NJ)

1980-01-01T23:59:59.000Z

456

Enhanced frequency up-conversion in Rb vapor  

E-Print Network (OSTI)

We demonstrate highly efficient generation of coherent 420 nm light via up-conversion of near-infrared lasers in a hot rubidium vapor cell. By optimizing pump polarizations and frequencies we achieve a single-pass conversion efficiency of 260%/W, significantly higher than in previous experiments. A full 2D exploration of the coherent light generation and fluorescence as a function of the pump frequencies reveals that coherent blue light is generated at 85Rb two-photon resonances, as predicted by theory, but at high vapor pressure it is suppressed in spectral regions that don't support phase matching or exhibit single-photon Kerr refraction. Favorable scaling of our current 1 mW blue beam power with additional pump power is predicted. Infrared pump polarization could be used for future intensity switching experiments.

Vernier, A; Riis, E; Arnold, A S

2009-01-01T23:59:59.000Z

457

Hydrocarbon pool and vapor fire data analysis. Final report  

SciTech Connect

The flame geometry and thermal radiation data from a series of large scale experiments involving liquefied petroleum gas (LPG) and gasoline spills on water were analyzed. The experiments were conducted at the Naval Weapons Center, China Lake, California. Two types of fires have been studied; namely, pool fires and vapor fires. The spill quantity varied from 4 m/sup 3/ to approximately 6 m/sup 3/. The LPG pool fire flame height to diameter ratio were between 3.5 and 4.5. The gasoline flame height was about 2. The flame emissive powers for LPG pool fires ranged from 78 kW/m/sup 2/ to 115 kW/m/sup 2/. The average surface emissive power for gasoline pool fire was 40 kW/m/sup 2/. The LPG vapor fire emissive power ranged from 159 to 269 kW/m/sup 2/. 63 figures, 13 tables.

Mudan, K.S.

1984-10-01T23:59:59.000Z

458

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents (OSTI)

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (approximately 1100.degree.-1300.degree. C.) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20-50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Brian, Riley (Willimantic, CT); Szreders, Bernard E. (Oakdale, CT)

1989-01-01T23:59:59.000Z

459

Fabrication of solid oxide fuel cell by electrochemical vapor deposition  

DOE Patents (OSTI)

In a high temperature solid oxide fuel cell (SOFC), the deposition of an impervious high density thin layer of electrically conductive interconnector material, such as magnesium doped lanthanum chromite, and of an electrolyte material, such as yttria stabilized zirconia, onto a porous support/air electrode substrate surface is carried out at high temperatures (/approximately/1100/degree/ /minus/ 1300/degree/C) by a process of electrochemical vapor deposition. In this process, the mixed chlorides of the specific metals involved react in the gaseous state with water vapor resulting in the deposit of an impervious thin oxide layer on the support tube/air electrode substrate of between 20--50 microns in thickness. An internal heater, such as a heat pipe, is placed within the support tube/air electrode substrate and induces a uniform temperature profile therein so as to afford precise and uniform oxide deposition kinetics in an arrangement which is particularly adapted for large scale, commercial fabrication of SOFCs.

Riley, B.; Szreders, B.E.

1988-04-26T23:59:59.000Z

460

Independent Oversight Assessment, Idaho Cleanup Project Sodium Bearing Waste Treatment Project- November 2012  

Energy.gov (U.S. Department of Energy (DOE))

Assessment of Nuclear Safety Culture at the Idaho Cleanup Project Sodium Bearing Waste Treatment Project

Note: This page contains sample records for the topic "watt sodium vapor" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Method of and apparatus for removing silicon from a high temperature sodium coolant  

DOE Patents (OSTI)

A method of and system for removing silicon from a high temperature liquid sodium coolant system for a nuclear reactor. The sodium is cooled to a temperature below the silicon saturation temperature and retained at such reduced temperature while inducing high turbulence into the sodium flow for promoting precipitation of silicon compounds and ultimate separation of silicon compound particles from the liquid sodium.

Yunker, Wayne H. (Richland, WA); Christiansen, David W. (Kennewick, WA)

1987-01-01T23:59:59.000Z

462

High average power magnetic modulator for metal vapor lasers  

DOE Patents (OSTI)

A three-stage magnetic modulator utilizing magnetic pulse compression designed to provide a 60 kV pulse to a copper vapor laser at a 4.5 kHz repetition rate is disclosed. This modulator operates at 34 kW input power. The circuit includes a step up auto transformer and utilizes a rod and plate stack construction technique to achieve a high packing factor.

Ball, Don G. (Livermore, CA); Birx, Daniel L. (Oakley, CA); Cook, Edward G. (Livermore, CA); Miller, John L. (Livermore, CA)

1994-01-01T23:59:59.000Z

463

System for the removal of contaminant soil-gas vapors  

DOE Patents (OSTI)

A system extracts contaminated vapors from soil or other subsurface regions by using changes in barometric pressure to operate sensitive check valves that control air entry and removal from wells in the ground. The system creates an efficient subterranean flow of air through a contaminated soil plume and causes final extraction of the contaminants from the soil to ambient air above ground without any external energy sources. 4 figs.

Weidner, J.R.; Downs, W.C.; Kaser, T.G.; Hall, H.J.

1997-12-16T23:59:59.000Z

464

Vaporizing Flow in Hot Fractures: Observations from Laboratory Experiments  

DOE Green Energy (OSTI)

Understanding water seepage in hot fractured rock is important in a number of fields including geothermal energy recovery and nuclear waste disposal. Heat-generating high-level nuclear waste packages which will be emplaced in the partially saturated fractured tuffs at the potential high-level nuclear waste repository at Yucca Mountain, Nevada, if it becomes a high-level nuclear waste repository, will cause significant impacts on moisture distribution and migration. Liquid water, which occupies anywhere from 30 to 100% of the porespace, will be vaporized as the temperature reaches the boiling temperature. Flowing primarily in fractures, the vapor will condense where it encounters cooler rock, generating mobile water. This water will flow under gravitational and capillary forces and may flow back to the vicinity of the emplaced waste where it may partially escape vaporization. Water flowing down (sub-) vertical fractures may migrate considerable distances through fractured rock that is at above-boiling temperatures; thus, flowing condensate may contact waste packages, and provide a pathway for the transport of water-soluble radionuclides downward to the saturated zone. Thermally-driven flow processes induced by repository heat may be as important or even more important for repository performance than natural infiltration. For a nominal thermal loading of 57 kW/acre, vaporization may generate an average equivalent percolation flux from condensate of 23.1 mm/yr over 1,000 years, and 5.2 mm/yr over 10,000 years. These numbers are comparable to or larger than current estimates of net infiltration at Yucca Mountain. This condensate, which is generated in the immediate vicinity (meters) of the waste packages, will likely have a larger impact on waste package and repository performance than a similar amount of water introduced at the land surface.

Kneafsey, T.; Pruess, K.

1998-12-01T23:59:59.000Z

465

Applications of Mechanical Vapor Recompression to Evaporation and Crystallization  

E-Print Network (OSTI)

Over the past 10-15 years, mechanical vapor recompression (MVR) has become the preferred system in many industrial evaporation and crystallization applications, because of its economy and simplicity of operation. In most instances, the need for steam to provide heat for the evaporation and cooling water for condensing the overhead vapors is virtually eliminated; and, at the same time, a wide range of turndown is available. An MVR is generally found to be the most economical choice when there is no boiler plant available or when electrical power is priced competitively in comparison to steam. Vapor recompression is accomplished using centrifugal, axial-flow, or positive displacement compressors and these compressors can be powered by electricity, steam turbine or a gas turbine. The use of an MVR Evaporator/Crystallizer provides a comparatively low cost means of expanding the production capability of an existing evaporation plant either by adding a "stand alone" unit or by reconfiguring a multiple-effect system into several single-effect MVR's.

Outland, J. S.

1995-04-01T23:59:59.000Z

466

Method of and apparatus for measuring vapor density  

DOE Patents (OSTI)

Apparatus and method are disclosed which determine the concentration of an individual component, such as water vapor, of a multi-component mixture, such as a gaseous mixture for cooling a nuclear reactor. A hygrometer apparatus includes an infrared source for producing a broadband infrared energy beam that includes a strong water vapor absorption band and a weak water vapor absorption region. The beam is chopped to select infrared pulses. A temporally first pulse has a wavelength in the weakly absorbing region, a temporally second pulse has a wavelength in the strong band and a temporally third pulse has a wavelength in the weakly absorbing region. A fourth reference pulse representing background radiation is interposed in such chopped pulses. An indium arsenide infrared sensor is responsive to the pulses for generating an output signal in proportion to an equation given in the patent where N1 is proportional to the transmission through the sample of the first signal, N4 is related to the background radiation, and [K2 (N2-N4) + K3 (N3-N4)] is the time-weighted average of the transmission through the sample of the second and third pulses applicable at the time of the second pulse, with the reference pulse N4 being subtracted in each case to render the ratio independent of variations in the background radiation. 11 figs.

Nelson, L.D.; Cerni, T.A.

1989-10-17T23:59:59.000Z

467

M.D.?Lukin, Storage of light in atomic vapor  

E-Print Network (OSTI)

We report an experiment in which a light pulse is decelerated and trapped in a vapor of Rb atoms, stored for a controlled period of time, and then released on demand. We accomplish this storage of light by dynamically reducing the group velocity of the light pulse to zero, so that the coherent excitation of the light is reversibly mapped into a collective Zeeman (spin) coherence of the Rb vapor. PACS numbers 03.67.-a, 42.50.-p, 42.50.Gy Typeset using REVTEX 1 Photons are the fastest and most robust carriers of information, but they are difficult to localize and store. The present Letter reports a proof-of-principle demonstration of a technique [1,2] to trap, store, and release excitations carried by light pulses. Specifically, a pulse of light which is several kilometers long in free space is compressed to a length of a few centimeters and then converted into collective spin excitations in a vapor of Rb atoms. After a controllable storage time, the process is reversed and the atomic coherence is converted

D. F. Phillips; A. Fleischhauer; A. Mair; R. L. Walsworth; M. D. Lukin

2001-01-01T23:59:59.000Z

468

Method of and apparatus for measuring vapor density  

DOE Patents (OSTI)

Apparatus and method determine the concentration of an individual component, such as water vapor, of a multi-component mixture, such as a gaseous mixture for cooling a nuclear reactor. A hygrometer apparatus includes an infrared source for producing a broadband infrared energy beam that includes a strong water vapor absorption band and a weak water vapor absorption region. The beam is chopped to select infrared pulses. A temporally first pulse has a wavelength in the weakly absorbing region, a temporally second pulse has a wavelength in the strong band and a temporally third pulse has a wavlength in the weakly absorbing region. A fourth reference pulse representing background radiation is interposed in such chopped pulses. An indium arsenide infrared sensor is responsive to the pulses for generating an output signal in proportion to: ##EQU1## where N1 is proportional to the transmission through the sample of the first signal, N4 is related to the background radiation, and [K2 (N2-N4)+K3 (N3-N4)] is the time-weighted average of the transmission through the sample of the second and third pulses applicable at the time of the second pulse, with the reference pulse N4 being subtracted in each case to render the ratio independent of variations in the background radiation.

Nelson, Loren D. (Morrison, CO); Cerni, Todd A. (Littleton, CO)

1989-01-01T23:59:59.000Z

469

Fast Flux Test Facility, Sodium Storage Facility project-specific project management plan  

SciTech Connect

This Project-Specific Project Management Plan describes the project management methods and controls used by the WHC Projects Department to manage Project 03-F-031. The Sodium Storage Facility provides for storage of the 260,000 gallons of sodium presently in the FFTF Plant. The facility will accept the molten sodium transferred from the FFTF sodium systems, and store the sodium in a solid state under an inert cover gas until such time as a Sodium Reaction Facility is available for final disposal of the sodium.

Shank, D.R.

1994-12-29T23:59:59.000Z

470

Tank 241-BY-110 Headspace Gas and Vapor Characterization Results for Samples Collected in November 1994. Revision 2  

Science Conference Proceedings (OSTI)

Significant changes have been made to all of the original vapor characterization reports. This report documents specific headspace gas and vapor characterization results for all vapor sampling events to date. In addition, changes have been made to the original vapor reports to qualify the data based on quality assurance issues associated with the performing laboratories.

Huckaby, J.L. [Pacific Northwest Lab., Washington, DC (United States); Bratzel, D.R. [Westinghouse Hanford Co., Richland, WA (United States)

1995-09-01T23:59:59.000Z

471

LESSONS LEARNED FROM PREVIOUS WASTE STORAGE TANK VAPOR CONTROL ATTEMPTS ON SINGLE SHELL TANK (SST) & DOUBLE SHELL TANK (DST) FARMS  

Science Conference Proceedings (OSTI)

This report forms the basis for a feasibility study and conceptual design to control vapor emissions from waste storage tanks at the Hanford Site. The Carbtrol, Vapor Mixing, and High Efficiency Gas Absorber (HEGA) vapor controls were evaluated to determine the lessons learned from previous failed vapor control attempts. This document illustrates the resulting findings based on that evaluation.

BAKER, D.M.

2004-08-03T23:59:59.000Z

472

Tank Vapor Characterization Project -- Headspace vapor characterization of Hanford waste Tank 241-C-107: Results from samples collected on 01/17/96  

DOE Green Energy (OSTI)

This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-C-107 (Tank C-107) at the Hanford Site in Washington State. The results described in this report were obtained to compare vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system with and without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane hydrocarbons (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs). Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.

Thomas, B.L.; Evans, J.C.; Pool, K.H.; Olsen, K.B.; Fruchter, J.S.; Silvers, K.L.

1996-07-01T23:59:59.000Z

473

Cannelton Utilities | Open Energy Information  

Open Energy Info (EERE)

Cannelton Utilities Cannelton Utilities Jump to: navigation, search Name Cannelton Utilities Place Indiana Utility Id 2964 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Outdoor Lighting: Murcury Vapor Light, 175 Watt Lighting Rate 1: Residential Residential Rate 2: Multi-Phase Commercial Rate 2: Single Phase Commercial Rate 3: Industrial Phase II Residential Rate 3: Industrial phase I Industrial Street Lighting: Decorative Metal Halide, 175 Watt Lighting Street Lighting: High Pressure Sodium, 100 Watt Lighting

474

Generation IV International Forum Signs Agreement to Collaborate on Sodium  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Forum Signs Agreement to Collaborate on Forum Signs Agreement to Collaborate on Sodium Cooled Fast Reactors Generation IV International Forum Signs Agreement to Collaborate on Sodium Cooled Fast Reactors February 17, 2006 - 11:58am Addthis FUKUI , JAPAN - The Department of Energy today announced that the United States signed a sodium-cooled fast reactor systems arrangement with France and Japan, providing the framework for collaboration among these countries on the research and development of these advanced nuclear reactors. The signing of the agreement took place on February 16, 2006. This arrangement will support the development of technologies associated with the U.S.-led Global Nuclear Energy Partnership (GNEP), announced earlier this month by Secretary of Energy Samuel W. Bodman. GNEP is a

475

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Federal - June 2012 Federal - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Federal - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Federal Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) DOE (Federal) Operational Readiness Review (D-ORR). The review was performed by the HSS Office of Safety and Emergency Management Evaluations and was intended to assess the effectiveness of the CORR process as implemented for the SBWTP-IWTU. This review also provides additional data regarding

476

Independent Oversight Review, Sodium Bearing Waste Treatment Project -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Contractor - June 2012 Contractor - June 2012 Independent Oversight Review, Sodium Bearing Waste Treatment Project - Contractor - June 2012 June 2012 Review of the Sodium Bearing Waste Treatment Project - Integrated Waste Treatment Unit Contractor Operational Readiness Review This report documents the U.S. Department of Energy (DOE) Office of Enforcement and Oversight (Independent Oversight), within the Office of Health, Safety and Security (HSS), independent review of the Sodium Bearing Waste Treatment Project-Integrated Waste Treatment Unit (SBWTP-IWTU) contractor Operational Readiness Review (C-ORR). The review was conducted at the Idaho Site from February 27 to March 6, 2012. This report discusses the background, scope, results, and conclusions of the review, as well as opp