Powered by Deep Web Technologies
Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Water Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Quality Water Quality We protect water quality through stormwater control measures and an extensive network of monitoring wells and stations encompassing groundwater, surface...

2

Cost-efficient monitoring of water quality in district heating systems This article examines the monitoring strategy for water quality in a large Danish district  

E-Print Network [OSTI]

Cost-efficient monitoring of water quality in district heating systems This article examines the monitoring strategy for water quality in a large Danish district heating system ­ and makes a proposal for a technical and economic improvement. Monitoring of water quality in district heating systems is necessary

3

South Asia transboundary water quality monitoring workshop summary report.  

SciTech Connect (OSTI)

The Cooperative Monitoring Center (CMC) promotes collaborations among scientists and researchers in several regions as a means of achieving common regional security objectives. To promote cooperation in South Asia on environmental research, an international working group made up of participants from Bangladesh, India, Nepal, Pakistan, and the United States convened in Kathmandu, Nepal, from February 17-23,2002. The workshop was held to further develop the South Asia Transboundary Water Quality Monitoring (SATWQM) project. The project is sponsored in part by the CMC located at Sandia National Laboratories in Albuquerque, New Mexico through funding provided by the US. Department of State, Regional Environmental Affairs Office, American Embassy, Kathmandu, Nepal, and the National Nuclear Security Administration's (NNSA) Office of Nonproliferation and National Security. This report summarizes the SATWQM project, the workshop objectives, process and results. The long-term interests of the participants are to develop systems for sharing regional environmental information as a means of building confidence and improving relations among South Asian countries. The more immediate interests of the group are focused on activities that foster regional sharing of water quality data in the Ganges and Indus River basins. Issues of concern to the SATWQM network participants include studying the impacts from untreated sewage and industrial effluents, agricultural run-off, salinity increases in fresh waters, the siltation and shifting of river channels, and the environmental degradation of critical habitats such as wetlands, protected forests, and endangered aquatic species conservation areas. The workshop focused on five objectives: (1) a deepened understanding of the partner organizations involved; (2) garnering the support of additional regional and national government and non-government organizations in South Asia involved in river water quality monitoring; (3) identification of sites within the region at which water quality data are to be collected; (4) instituting a data and information collection and sharing process; and, (5) training of partners in the use of water quality monitoring equipment.

Betsill, Jeffrey David; Littlefield, Adriane C.; Luetters, Frederick O.; Rajen, Gaurav

2003-04-01T23:59:59.000Z

4

Monitoring and Managing Water Quality in the San Francisco Estuary San Francisco Estuary Institute and the  

E-Print Network [OSTI]

Monitoring and Managing Water Quality in the San Francisco Estuary San Francisco Estuary Institute;Contribution 517 Monitoring and Managing Water Quality in the San Francisco Estuary San Francisco Estuary information generated each year on water quality in the Estu- ary accessible to water quality managers

5

The Role of Isotopes in Monitoring Water Quality Impacts Associated with Shale Gas Drilling  

E-Print Network [OSTI]

The Role of Isotopes in Monitoring Water Quality Impacts Associated with Shale Gas Drilling Methane contamination is usually due to natural causes; however, it can also be the result of drilling activities, including shale gas drilling. Monitoring techniques exist for detecting methane and, in some cases

Wang, Z. Jane

6

A Report of the Regional Monitoring Program for Water Quality in the San Francisco Estuary pollutant effects on aquatic life  

E-Print Network [OSTI]

Program for Water Quality in the San Francisco Estuary 2011 pollutant effects on aquatic life pulse goals of Bay water quality managers is to ensure that pollutants do not interfere with the abilityA Report of the Regional Monitoring Program for Water Quality in the San Francisco Estuary

7

Synthesis of gold nano-particles in a microfluidic platform for water quality monitoring applications  

E-Print Network [OSTI]

A microfluidic lab-on-a-chip (LOC) device for in-situ synthesis of gold nano-particles was developed. The long term goal is to develop a portable hand-held diagnostic platform for monitoring water quality (e.g., detecting metal ion pollutants...

Datta, Sayak

2009-05-15T23:59:59.000Z

8

2-3. Generic Approaches Towards Water Quality Monitoring Based on Paleolimnology  

E-Print Network [OSTI]

phosphorus analysis of Lake St-Charles, the principal drinking water supply for Québec City, #12;62 R environmental records for lake and river ecosystems provide a valuable generic tool for water quality management by way of water quality research on three ecosystems in Québec, Canada. Lake St-Augustin is a small lake

Vincent, Warwick F.

9

Water Quality Modeling and Monitoring in the California North Delta Area Raffi Jirair Moughamian  

E-Print Network [OSTI]

hydraulic model of the northern part of the Sacramento-San Joaquin Delta (the North Delta). It was produced A water quality model, including salinity and temperature, has been linked to a one-dimensional, MIKE 11 Description.................................................................................20 Hydrodynamics

Schladow, S. Geoffrey

10

Water quality monitoring at the Hoe Creek test site: review and preliminary conclusions  

SciTech Connect (OSTI)

Post-burn monitoring of the ground water near to the Hoe creek underground coal gasification site showed that a broad range of gasification products had been introduced into the water system. Although many of these contaminants were eventually absorbed by the surrounding coal, some chemicals continued to appear in the water in concentrations higher than pre-test levels for several years after gasification. Possible mechanisms by which the contaminants entered the ground water include: (1) leakage of pyrolysis products; (2) post-burn leaching of coal ash and overburden rubble by returning ground water; and (3) dissolution of minerals outside the cavity by the CO/SUB/2 generated during gasification.

Wang, F.T.

1983-01-01T23:59:59.000Z

11

Household Water Quality Home Water Quality Problems  

E-Print Network [OSTI]

in water heater. Scale buildup in pipes and re duced water flow. Hard water due to calcium and magnesiumHousehold Water Quality Home Water Quality Problems­ Causes and Treatments Blake Ross, Extension Many areas have water containing impurities from natural or artificial sources. These impurities may

Liskiewicz, Maciej

12

Water Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of desalination research. The primary technological method of generating additional water supplies is through desalination and enhanced water reuse and recycling technologies....

13

Water-quality monitoring at the Hoe Creek test site: review and preliminary conclusions  

SciTech Connect (OSTI)

It has been shown that underground coal gasification (UCG) may introduce a broad range of residual gasification products into the groundwater of a coal aquifer. Sorption of many contaminants by the coal itself is an important factor in restricting the migration of these contaminants in the ground water. However, field studies, conducted at Lawrence Livermore National Laboratory's Hoe Creek site, have shown that sorption of organic compounds by coal is not as effective as expected, perhaps because the coal surface area is limited. Furthermore, if severe roof collapse has taken place during gasification, non-coal aquifers located above the gasified coal seam may be interconnected with the coal aquifer, and contaminants may enter these non-coal aquifers, in which sorption is even less effective. The Hoe Creek II and III experiments have provided opportunities to study the contamination of a sand aquifer located above a gasified coal seam in a hydrological recharge area. Preliminary results indicate that the water in the overlying sand aquifer is much less contaminated with organic compounds than the water in the gasified coal aquifer. In conducting these field investigations, valuable lessons ere learned concerning groundwater monitoring. A suggested monitoring strategy is discussed.

Wang, F T; Mead, S W; Stuermer, D H

1982-05-20T23:59:59.000Z

14

Water Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

which can lead to public health problems. * MtBE (Methyl tert Butyl Ether), a gasoline additive, has begun to contaminate ground water supplies. * Similarly, perchlorate has...

15

Water Resources Water Quality and Water Treatment  

E-Print Network [OSTI]

Water Resources TD 603 Lecture 1: Water Quality and Water Treatment CTARA Indian Institute of Technology, Bombay 2nd November, 2011 #12;OVERVIEW Water Quality WATER TREATMENT PLANTS WATER TREATMENT PLANTS WATER TREATMENT PLANTS WATER TRE OVERVIEW OF THE LECTURE 1. Water Distribution Schemes Hand Pump

Sohoni, Milind

16

LA-UR-00-949 Perched Zone Monitoring Well 1995 Analytical Water Quality and Hydrology Group, ESH-18  

E-Print Network [OSTI]

and Hydrology Group, ESH-18 Mary Mullen Ecology Group, ESH-20 David B. Rogers Water Quality and Hydrology Group

17

Water Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched FerromagnetismWaste and Materials Disposition InformationInteractionsWater

18

Water Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLasDelivered energy consumption byAbout Printable VersionProtectiveWaste to beswim WatchingWaterW

19

Water-quality monitoring at the Hoe Creek test site: review and preliminary conclusions  

SciTech Connect (OSTI)

It has been shown that underground coal gasification (UCG) may introduce a broad range of residual gasification products into the groundwater of a coal aquifer. Sorption of many contaminants by the coal itself is an important factor in restricting the migration of these contaminants in the groundwater. However, our field studies at the Lawrence Livermore National Laboratory (LLNL) Hoe Creek site in northeastern Wyoming have shown that sorption of organic compounds by coal is not as effective as expected, perhaps because the coal surface area is limited. Furthermore, if severe roof collapse has taken place during gasification, non-coal aquifers located above the gasified coal seam may be interconnected with the coal aquifer. Contaminants may enter these non-coal aquifers, in which sorption is even less effective. The Hoe Creek II and III experiments have enabled us to study the contamination of a sand aquifer located above a gasified coal seam in a hydrological recharge area. Our preliminary results indicate that the water in the overlying sand aquifer is much less contaminated with organic compounds than that in the gasified coal aquifer. In conducting these field investigations, we have also learned valuable lessons concerning a strategy for groundwater monitoring. 21 figures.

Wang, F.T.; Mead, S.W.; Stuermer, D.H.

1983-04-16T23:59:59.000Z

20

MONITORING A TOXIC CYANOBACTERIA BLOOM IN LAKE BOURGET (FRANCE) AND ITS CONSEQUENCES FOR WATER QUALITY  

E-Print Network [OSTI]

the turbidity of the water in treatment units providing drinking water. These central supplies obtain their lake of Feuillade et al. [3]. The samples were taken in the water treatment units, before (water intake in treatment unit) and at the end of the treatment steps (in water reaching the consumers). Intracellular

Jacquet, Stéphan

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

General Water Quality (Oklahoma)  

Broader source: Energy.gov [DOE]

The purpose of this water quality rule is to protect, maintain and improve the quality of waters of the State. Any applicant for a federal license, permit or project to conduct any activity...

22

State Water Quality (Virginia)  

Broader source: Energy.gov [DOE]

It is the policy of the Commonwealth of Virginia to: (1) protect existing high quality state waters and restore the quality of all other state waters to permit all reasonable public uses and...

23

North Central Texas Water Quality Final Report  

E-Print Network [OSTI]

source pollution sources in the watershed. The District has already initiated efforts to address the water quality issues, developing a water quality monitoring program to collect data for these reservoirs and their associated watersheds. The District... has collected water quality data for nearly 40 parameters since 1989. Effluent discharges from the wastewater treatment plans and nonpoint source pollution from urban and agricultural runoff are reported as the major causes for water quality...

Berthold, T. Allen

24

Health and water quality monitoring of Pure Home Water's ceramic filter dissemination in the northern region of Ghana  

E-Print Network [OSTI]

Pure Home Water (PHW) is a social enterprise that promotes and disseminates household drinking water technologies in the Northern Region of Ghana. Currently their main product is a pot-shaped Potters for Peace-type ceramic ...

Johnson, Sophie M. (Sophie Marie)

2007-01-01T23:59:59.000Z

25

Water quality monitoring at the Hoe Creek test site: review and preliminary conclusions  

SciTech Connect (OSTI)

It has been shown that underground coal gasification (UCG) may introduce a broad range of residual products into the groundwater of a coal aquifer. Sorption of many contaminants by the coal itself is an important factor in restricting the migration of these contaminants in the groundwater. However, our field studies at the Lawrence Livermore National Laboratory (LLNL) Hoe Creek site in northeastern Wyoming have shown that sorption of organic compounds by coal is not as effective as expected, perhaps because the coal surface area is limited. Furthermore, if severe roof collapse has taken place during gasification, non-coal aquifers located above the gasified coal seam may become interconnected with the cavity. Contaminants may enter these non-coal aquifers, in which sorption is even less effective. The Hoe Creek II and III experiments have enabled us to study the contamination of a sand aquifer located above a gasified coal seam in a hydrological recharge area. The preliminary results indicate that the water in the overlying sand aquifer is much less contaminated with organic compounds than that in the gasified

Wang, F.T.; Mead, S.W.; Sturmer, D.H.

1983-01-01T23:59:59.000Z

26

Water Quality (Oklahoma)  

Broader source: Energy.gov [DOE]

The Water Quality Act establishes cumulative remedies to prevent, abate and control the pollution of the waters of the state. The act establishes responsibilities of the Oklahoma Department of...

27

Surface Water Monitoring and Assessment (Ohio)  

Broader source: Energy.gov [DOE]

This law establishes criteria for three levels of credible data for a surface water quality monitoring and assessment program and establishes the necessary training and experience for persons to...

28

Water Quality Control Act (Tennessee)  

Broader source: Energy.gov [DOE]

The Water Quality Control Act (WQCA) establishes the water pollution control program. The WQCA identifies the responsibilities and extent of authority for the Commissioner of the Water Quality...

29

Water Quality Control (Texas)  

Broader source: Energy.gov [DOE]

The policy of the state of Texas is to promote the quality of the state's water by regulating existing industries, taking into consideration the economic development of the state, and by...

30

Water Quality Criteria Introduction ....................................................................................................................................798  

E-Print Network [OSTI]

APPENDIX G Water Quality Criteria CONTENTS Introduction ....................................................................................................................................798 EPA's Water Quality Criteria and Standards Plan -- Priorities for the Future............................798 Compilation of Recommended Water Quality Criteria and EPA's Process for Deriving New

Pitt, Robert E.

31

Quality monitored distributed voting system  

DOE Patents [OSTI]

A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system. 6 figs.

Skogmo, D.

1997-03-18T23:59:59.000Z

32

Surface Water Quality Standards (Nebraska)  

Broader source: Energy.gov [DOE]

These regulations, promulgated by the Department of Environmental Quality, contain surface water quality standards, stream classifications, discussion of lakes and impounded basins, and water...

33

Water Quality Trading Program (Ohio)  

Broader source: Energy.gov [DOE]

Water quality trading is a tool for achieving water quality improvements. Under the right circumstances, trading has the potential to yield both environmental and economic benefits, while...

34

Surface Water Quality Standards (Kansas)  

Broader source: Energy.gov [DOE]

This act states regulations for the quality of surface water in the state. It also states designated uses of classified surface waters, surface water quality criteria and an antidegradation policy...

35

E-mail: whare@udc.eduhttp://www.udc.edu//wrri Integrating Water Quality Monitoring and Modeling as a Tool for  

E-Print Network [OSTI]

system Ground water quality Storm water Wastewater treatment plant Rainfall runoff Environmental and biological water quality parameters in water and wastewater. Examples are: (1) Senion2, (2) Titrino, (3) p the research and training needs of our faculty, students as well as water and wastewater operators. The main

District of Columbia, University of the

36

Texas Surface Water Quality Standards  

E-Print Network [OSTI]

1 Texas Surface Water Quality Standards 30 TAC Chapter 307 Lori Hamilton Water Quality Standards of the water quality standards for a water body will be conducted Types of UAAs Aquatic Life Use (ALU) UAAs 2 procedures in conjunction with Standards revision Before Conducting a UAA Coordinate with your TCEQ project

37

Water Quality Standards Implementation (Oklahoma)  

Broader source: Energy.gov [DOE]

The Oklahoma Department of Environmental Quality regulates Oklahoma's Water Quality Standards. The law states the requirements and standards for point source discharges. It also establishes...

38

The Development and Optimization of Techniques for Monitoring Water Quality on-Board Spacecraft Using Colorimetric Solid-Phase Extraction (C-SPE)  

SciTech Connect (OSTI)

The main focus of this dissertation is the design, development, and ground and microgravity validation of methods for monitoring drinking water quality on-board NASA spacecraft using clorimetric-solid phase extraction (C-SPE). The Introduction will overview the need for in-flight water quality analysis and will detail some of the challenges associated with operations in the absence of gravity. The ability of C-SPE methods to meet these challenges will then be discussed, followed by a literature review on existing applications of C-SPE and similar techniques. Finally, a brief discussion of diffuse reflectance spectroscopy theory, which provides a means for analyte identification and quantification in C-SPE analyses, is presented. Following the Introduction, four research chapters are presented as separate manuscripts. Chapter 1 reports the results from microgravity testing of existing C-SPE methods and procedures aboard NASA's C-9 microgravity simulator. Chapter 2 discusses the development of a C-SPE method for determining the total concentration of biocidal silver (i.e., in both dissolved and colloidal forms) in water samples. Chapter 3 presents the first application of the C-SPE technique to the determination of an organic analyte (i.e., formaldehyde). Chapter 4, which is a departure from the main focus of the thesis, details the results of an investigation into the effect of substrate rotation on the kinetics involved in the antigen and labeling steps in sandwich immunoassays. These research chapters are followed by general conclusions and a prospectus section.

April Hill

2007-12-01T23:59:59.000Z

39

Installation of River and Drain Instrumentation Stations to Monitor Flow and Water Quality and Internet Data Sharing  

E-Print Network [OSTI]

del Norte Watershed Council With funding support in part by the U.S Department of Interior, Bureau of Reclamation El Paso Water Utilities, U.S. Army Corps of Engineers through Texas AgriLife Research and the U.S. Department of Interior, Geological.../Texas AgriLife research, United States Bureau of Reclamation, United States Geological Survey, United States Army Corps of Engineers, and the United States Section of the International Boundary and Water Commission (IBWC). The Project is also based...

Sheng, Z.; Brown, C.; Creel, B.; Srinivasan, R.; Michelsen, A.; Fahy, M. P.

40

Water Quality Regulations (Rhode Island)  

Broader source: Energy.gov [DOE]

The purpose of these regulations is to establish water quality standards for the state's surface waters. These standards are intended to restore, preserve and enhance the physical, chemical and...

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Bull World Health Organ 2012;90:228235A |doi:10.2471/BLT.11.094284 Accounting for water quality in monitoring access to safe  

E-Print Network [OSTI]

access to safe drinking-water and basic sanitation".1 The World Health Organization (WHO) and the United Programme for Water Supply and Sanitation.2 However, the functioning of the Joint Monitoring Programme-, middle- and high- income countries. Moreover, data comparability between countries was poor since

Bristol, University of

42

publication 426-042 Urban Water-Quality Management  

E-Print Network [OSTI]

publication 426-042 Urban Water-Quality Management Winterizing the Water Garden Lynnette Swanson. Prepare the pond for the winter months by managing the plants, cleaning the pond, and monitoring the water Traci Gilland, Extension Agent, Portsmouth Water gardens require maintenance throughout the year

Liskiewicz, Maciej

43

Hanford Site ground-water monitoring for 1994  

SciTech Connect (OSTI)

This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1994 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiologic and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1994 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1993 and June 1994. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal.

Dresel, P.E.; Thorne, P.D.; Luttrell, S.P. [and others

1995-08-01T23:59:59.000Z

44

Water Quality Act (New Mexico)  

Broader source: Energy.gov [DOE]

This act establishes the Water Quality Control Commission and states the powers and duties of the commission. Rules are stated for adoption of regulations and standards and information is provided...

45

Surface Water Quality Standards  

E-Print Network [OSTI]

recreational uses. ?The Commission will seek substantial additional public comment on any proposed changes to the standards before adopting them into the state admin- istrative code,? Davenport said. ?Because of the com- plexity and regulatory importance... Conservation Board?s state watershed coordinator, said the standards for contact recreation, with only a few exceptions, are uniformly applied regardless of water body type or the actual level of recreation use. ?Because a minimum of 10 water samples over a...

Wythe, Kathy

2007-01-01T23:59:59.000Z

46

Irrigation Monitoring with Soil Water Sensors  

E-Print Network [OSTI]

Monitoring soil water content is essential if growers want to optimize production, conserve water, reduce environmental impacts and save money. This publication illustrates how soil moisture monitoring can improve irrigation decisions and how...

Enciso, Juan; Porter, Dana; Peries, Xavier

2007-01-19T23:59:59.000Z

47

Brackish water pond polyculture of estuarine fishes in power plant thermal effluent and their use as biological monitors of water quality  

E-Print Network [OSTI]

-Old Striped Mullet, 2-Year-Old Atlantic Croaker, 1-Year-Old Southern Flounder Miscellaneous Organisms Unstocked-Unfiltered Ponds. . . . . . . . . . . . Stocked Ponds. Selected Metals and Pesticides Analyses. . . . 21 21 22 23 26 33 40 43 43 46... Station consists of three 750 megawatt units. Name-plate ratings specify maximum cooling water requirements of 76, 840 m /hr. However, ac- 3 tual pumping rates exceed the name-plate ratings by 2% for unit 1, 6% for unit 2, and less than 1% for unit 3...

Branch, Mark Roy

1977-01-01T23:59:59.000Z

48

Brackish water pond culture of fishes and their use as biological monitors of the water quality of thermal effluent from a power station  

E-Print Network [OSTI]

designed temperature change (bT) in the cooling water is 11. 1 C. Ponds Adjacent to the discharge canal are 25 ponds (Fig. 2); 16 ponds were used in this study. Each pond had 0. 1 ha suxface area and was 82. 3 m long, 12. 2 m wide, 1. 5 m deep... FIANT CEGAR RAVOU TRINITY BAY ~ 0 . . 000 ?' 8 OGLl II 0 Kll 0 'll El 9'll . 0 LI 0 GALVESTON BAY ll 'll ' I E RA 5 90 MAF AREA GULF OF MEXICO 9 SG Figure 1. --Map showing location of power plant and research facilities. DRAINAGE...

Kaehler, Todd

1975-01-01T23:59:59.000Z

49

Radionuclide Sensors for Water Monitoring  

SciTech Connect (OSTI)

Radionuclide contamination in the soil and groundwater at U.S. Department of Energy (DOE) sites is a severe problem that requires monitoring and remediation. Radionuclide measurement techniques are needed to monitor surface waters, groundwater, and process waters. Typically, water samples are collected and transported to an analytical laboratory, where costly radiochemical analyses are performed. To date, there has been very little development of selective radionuclide sensors for alpha- and beta-emitting radionuclides such as 90Sr, 99Tc, and various actinides of interest. The objective of this project is to investigate novel sensor concepts and materials for sensitive and selective determination of beta- and alpha-emitting radionuclide contaminants in water. To meet the requirements for low-level, isotope-specific detection, the proposed sensors are based on radiometric detection. As a means to address the fundamental challenge of the short ranges of beta and alpha particles in water, our overall approach is based on localization of preconcentration/separation chemistries directly on or within the active area of a radioactivity detector. Automated microfluidics is used for sample manipulation and sensor regeneration or renewal. The outcome of these investigations will be the knowledge necessary to choose appropriate chemistries for selective preconcentration of radionuclides from environmental samples, new materials that combine chemical selectivity with scintillating properties, new materials that add chemical selectivity to solid-state diode detectors, new preconcentrating column sensors, and improved instrumentation and signal processing for selective radionuclide sensors. New knowledge will provide the basis for designing effective probes and instrumentation for field and in situ measurements.

Grate, Jay W.; Egorov, Oleg B.; DeVol, Timothy A.

2003-06-01T23:59:59.000Z

50

Radionuclide Sensors for Water Monitoring  

SciTech Connect (OSTI)

Radionuclide contamination in the soil and groundwater at U.S. Department of Energy (DOE) sites is a severe problem that requires monitoring and remediation. Radionuclide measurement techniques are needed to monitor surface waters, groundwater, and process waters. Typically, water samples are collected and transported to an analytical laboratory, where costly radiochemical analyses are performed. To date, there has been very little development of selective radionuclide sensors for alpha- and beta-emitting radionuclides such as 90Sr, 99Tc, and various actinides of interest. The objective of this project is to investigate novel sensor concepts and materials for sensitive and selective determination of beta- and alpha-emitting radionuclide contaminants in water. To meet the requirements for low-level, isotope-specific detection, the proposed sensors are based on radiometric detection. As a means to address the fundamental challenge of the short ranges of beta and alpha particle s in water, our overall approach is based on localization of preconcentration/separation chemistries directly on or within the active area of a radioactivity detector. Automated microfluidics is used for sample manipulation and sensor regeneration or renewal. The outcome of these investigations will be the knowledge necessary to choose appropriate chemistries for selective preconcentration of radionuclides from environmental samples, new materials that combine chemical selectivity with scintillating properties, new materials that add chemical selectivity to solid-state diode detectors, new preconcentrating column sensors, and improved instrumentation and signal processing for selective radionuclide sensors. New knowledge will provide the basis for designing effective probes and instrumentation for field and in situ measurements.

Grate, Jay W.; Egorov, Oleg B.; DeVol, Timothy A.

2004-06-29T23:59:59.000Z

51

Georgia Water Quality Control Act (Georgia)  

Broader source: Energy.gov [DOE]

The Georgia Water Quality Control Act (WQCA) is a set of environmental regulations and permitting requirements that comply with the federal Clean Water Act. The Georgia Water Quality Control Act...

52

Assessment of Potential Contribution of Woodland Creation to Mitigating the Impacts of Agriculture on Water Quality  

E-Print Network [OSTI]

PLANTS WATER TRE WATER QUALITY MONITORING NETWORK I Central Pollution Control Board (CPCB) hasEF) promotes basin-wide pollution control strategies. It liaises with State Water Pollution Control BoardsWater Resources TD 603 Lecture 1: Water Quality and Water Treatment CTARA Indian Institute

53

Hanford Site ground-water monitoring for 1993  

SciTech Connect (OSTI)

This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1993 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiological and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1993 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1992 and June 1993. The greatest declines occurred in the 200-West Area. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal. Water levels remained nearly constant in the vicinity of B Pond, as a result of continued disposal to the pond. Water levels measured from wells in the unconfined aquifer north and east of the Columbia River indicate that the primary source of recharge is irrigation practices.

Dresel, P.E.; Luttrell, S.P.; Evans, J.C. [and others

1994-09-01T23:59:59.000Z

54

Chemical drinking water quality in Ghana: Water costs and scope for advanced treatment   

E-Print Network [OSTI]

To reduce child mortality and improve health in Ghana boreholes and wells are being installed across the country by the private sector, NGOs and the Ghanaian government. Water quality is not generally monitored once a ...

Rossiter, Helfrid M.A.; Owusu, Peter A; Awuah, Esi; MacDonald, Alan M; Schäfer, Andrea

2010-01-01T23:59:59.000Z

55

Monitoring SERC Technologies — Solar Hot Water  

Broader source: Energy.gov [DOE]

A webinar by National Renewable Energy Laboratory analyst Eliza Hotchkiss on Solar Hot Water systems and how to properly monitor their installation.

56

Requirements Governing Water Quality Standards (West Virginia)  

Broader source: Energy.gov [DOE]

This rule establishes the requirements governing the discharge or deposit of sewage, industrial wastes and other wastes into waters and establishes water quality standards.

57

Water quality management plan for Cherokee Reservoir  

SciTech Connect (OSTI)

The management plan provides an assessment of Cherokee Reservoir's current water quality, identifies those factors which affect reservoir water quality, and develops recommendations aimed at restoring or maintaining water quality at levels sufficient to support diverse beneficial uses. 20 references, 8 figures, 15 tables. (ACR)

Not Available

1984-01-01T23:59:59.000Z

58

Participatory Patterns in an International Air Quality Monitoring Initiative  

E-Print Network [OSTI]

The issue of sustainability is at the top of the political and societal agenda, being considered of extreme importance and urgency. Human individual action impacts the environment both locally (e.g., local air/water quality, noise disturbance) and globally (e.g., climate change, resource use). Urban environments represent a crucial example, with an increasing realization that the most effective way of producing a change is involving the citizens themselves in monitoring campaigns (a citizen science bottom-up approach). This is possible by developing novel technologies and IT infrastructures enabling large citizen participation. Here, in the wider framework of one of the first such projects, we show results from an international competition where citizens were involved in mobile air pollution monitoring using low cost sensing devices, combined with a web-based game to monitor perceived levels of pollution. Measures of shift in perceptions over the course of the campaign are provided, together with insights int...

Sîrbu, Alina; Caminiti, Saverio; De Baets, Bernard; Elen, Bart; Francis, Louise; Gravino, Pietro; Hotho, Andreas; Ingarra, Stefano; Loreto, Vittorio; Molino, Andrea; Mueller, Juergen; Peters, Jan; Ricchiuti, Ferdinando; Saracino, Fabio; Servedio, Vito D P; Stumme, Gerd; Theunis, Jan; Tria, Francesca; Bossche, Joris Van den

2015-01-01T23:59:59.000Z

59

California State Water Resources Control Board 401 Water Quality...  

Open Energy Info (EERE)

navigation, search OpenEI Reference LibraryAdd to library Web Site: California State Water Resources Control Board 401 Water Quality Certification Website Abstract This website...

60

Distrbuted Sensing Systems for Water Quality Assesment and Management  

E-Print Network [OSTI]

Sensing Systems for Water Quality Assessment and ManagementSensing Systems for Water Quality Assessment and ManagementSensing Systems for Water Quality Assessment and Management

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

History, contamination and monitoring of water bodies at the P/A Mayak  

SciTech Connect (OSTI)

The facts concerning the history and contamination data of surface water at Mayak Production Association are given in the article. Data about the monitoring of contaminated water are presented. The monitoring program solved three main problems: assessment of the water quality of basins, examination of water quality in accordance with actual specifications, and reception of new data about the migration of the most important radionuclides.

Drozhko, E.G.; Sharalapov, V.I.; Posokhov, A.K.; Kuzina, N.V.; Postovalova, G.A. [Ministry of Atomic Energy, Chelyabinsk (Russian Federation)

1993-12-31T23:59:59.000Z

62

Water-Level Monitoring Plan for the Hanford Groundwater Monitoring Project  

SciTech Connect (OSTI)

This document presents the water-level monitoring plan for the Hanford Groundwater Monitoring Project, conducted by the Pacific Northwest National Laboratory (PNNL). Water-level monitoring of the groundwater system beneath the Hanford Site is performed to fulfill the requirements of various state and federal regulations, orders, and agreements. The primary objective of this monitoring is to determine groundwater flow rates and directions. To meet this and other objectives, water-levels are measured annually in monitoring wells completed within the unconfined aquifer system, the upper basalt-confined aquifer system, and in the lower basalt-confined aquifers for surveillance monitoring. At regulated waste units, water levels are taken monthly, quarterly, semi-annually, or annually, depending on the hydrogeologic conditions and regulatory status of a given site. The techniques used to collect water-level data are described in this document along with the factors that affect the quality of the data and the strategies employed by the project to minimize error in the measurement and interpretation of water levels. Well networks are presented for monitoring the unconfined aquifer system, the upper basalt-confined aquifer system, and the lower basalt-confined aquifers, all at a regional scale (surveillance monitoring), as well as the local-scale well networks for each of the regulated waste units studied by this project (regulated-unit monitoring). The criteria used to select wells for water-table monitoring are discussed. It is observed that poor well coverage for surveillance water-table monitoring exists south and west of the 200-West Area, south of the 100-F Area, and east of B Pond and the Treated Effluent Disposal Facility (TEDF). This poor coverage results from a lack of wells suitable for water-table monitoring, and causes uncertainty in representation of the regional water-table in these areas. These deficiencies are regional in scale and apply to regions outside of the operational areas, so these deficiencies do not in anyway reflect on the adequacy of the local-scale well networks used for regulated-unit monitoring. The sediments comprising the unconfined aquifer system have been subdivided into nine hydro-geologic units. The specific hydrogeologic units present within the saturated open interval of each onsite well used for water-level measurements are identified. This was accomplished by geologic interpretation at individual wells combined with extrapolation to nearby wells using a three-dimensional, regional-scale conceptual model of the Hanford Site hydrostratigraphy.

D.R. Newcomer; J.P. McDonald; M.A. Chamness

1999-09-30T23:59:59.000Z

63

Nutrient Management Module No. 12 Water Quality  

E-Print Network [OSTI]

Nutrient Management Module No. 12 Water Quality Considerations and Regulations by Susan Mc Management Competency Area II: Nutrient movement in soil and water. Objectives After completing this module issues 3.Become familiar with federal and state water quality regulations 4.Identify Best Management

Lawrence, Rick L.

64

Agricultural Management, Water Quality and Phosphorus  

E-Print Network [OSTI]

Agricultural Management, Water Quality and Phosphorus: The Long and Winding Road Andrew Sharpley #12;In the beginning Agriculture and water quality Targeted watershed P management Linking ecosystem;#12;Optimal soil PO concentrations for plant growth ~0.20 mg/L #12;For flowing waters ~0.01 to 0.10 mg/L #12

65

Soil Quality Information Sheet Rangeland Soil Quality--Water Erosion  

E-Print Network [OSTI]

Soil Quality Information Sheet Rangeland Soil Quality--Water Erosion USDA, Natural Resources and removal of soil material by water. The process may be natural or accelerated by human activity. The rate of erosion may be very slow to very rapid, depending on the soil, the local landscape, and weather conditions

66

Federal, State, and Local Water Quality Control  

E-Print Network [OSTI]

and non-point pollution is causing many water bodies to fail state water quality standards. Since in many cases these polluted water bodies are vital to communi- ties as both a source of drinking water-5-23.1. These two laws are intended to protect water bodies from excessive point and non-point pollution

Rosemond, Amy Daum

67

Water Quality Program, Volume 1 (Alabama)  

Broader source: Energy.gov [DOE]

This volume of the water quality program mainly deals with the National Pollutant Discharge Elimination System. National Pollutant Discharge Elimination System" or "(NPDES)" means the national...

68

Water Quality Program, Volume 2 (Alabama)  

Broader source: Energy.gov [DOE]

This volume of the water quality program mainly deals with Technical Standards, Corrective Action Requirements and Financial Responsibility for Owners and Operators of Underground Storage Tanks....

69

Montana Water Quality Permit Application, Nondegradation Authorization...  

Open Energy Info (EERE)

LibraryAdd to library PermittingRegulatory Guidance - Supplemental Material: Montana Water Quality Permit Application, Nondegradation Authorization, and Permit FeesPermitting...

70

Pesticide Properties that Affect Water Quality  

E-Print Network [OSTI]

In order to keep our water supplies safe from pesticide contamination, we must understand which pesticide properties affect water quality, and how. The subject is complex, as properties such as pesticide class, formulation, toxicity, dose, effective...

Stevenson, Douglas; Baumann, Paul A.; Jackman, John A.

1997-06-30T23:59:59.000Z

71

2012 BNL Water Quality Consumer Confidence Report  

E-Print Network [OSTI]

includes five wells dedicated to pumping drinking water and the Water Treatment Facility in Bldg. 624 (see-step process to remove iron at the Water Treatment Facil- ity (see photo essay on page 4). While being2012 BNL Water Quality Consumer Confidence Report This special edition of the Brookhaven Bulletin

72

Report Concerns: Storm Water Quality Hotline  

E-Print Network [OSTI]

into storm drains, or suspicious activi- ties that may cause environmental harm to the Storm Water Quality was created for the Storm Water Management Program http://cleanwater.ucsc.edu Contact us at: cleanwater Management Program and UCSC Storm Water Management Plan at cleanwater.ucsc.edu Storm Water Management: 1

California at Santa Cruz, University of

73

Water quality for secondary and tertiary oil recovery  

SciTech Connect (OSTI)

A key element in many secondary and tertiary oil recovery processes is the injection of water into an oil-bearing formation. Water is the fluid which displaces the oil in the pore space of the rock. A successful waterflood requires more than the availability of water and the pumps and piping to inject the water into the formation. It requires an understanding of how water enters the oil bearing formation and what happens once the injected water comes into contact with the rock or sand, the oil, and the water already in the reservoir. Problems in injectivity will arise unless care and constant monitoring are exercised in the water system for a flood operation. This study examines water availability and quality in relation to waterflooding.

Michnick, M.J.

1983-01-01T23:59:59.000Z

74

Condensing Hybrid Water Heater Monitoring Field Evaluation  

SciTech Connect (OSTI)

This paper summarizes the Mascot home, an abandoned property that was extensively renovated. Several efficiency upgrades were integrated into this home, of particular interest, a unique water heater (a Navien CR240-A). Field monitoring was performed to determine the in-use efficiency of the hybrid condensing water heater. The results were compared to the unit's rated efficiency. This unit is Energy Star qualified and one of the most efficient gas water heaters currently available on the market.

Maguire, J.; Earle, L.; Booten, C.; Hancock, C. E.

2011-10-01T23:59:59.000Z

75

assessing water quality: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of Woodland Creation to Mitigating the Impacts of Agriculture on Water Quality Renewable Energy Websites Summary: on Water Quality The report Woodland for Water:...

76

assess water quality: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of Woodland Creation to Mitigating the Impacts of Agriculture on Water Quality Renewable Energy Websites Summary: on Water Quality The report Woodland for Water:...

77

Water Quality Criteria for Intrastate, Interstate, and Coastal Water (Mississippi)  

Broader source: Energy.gov [DOE]

The Water Quality Criteria for Intrastate, Interstate, and Coastal Water were created to embody both state and federal law. State law mandates the protection of public health and welfare and the...

78

16 au Spring 2012 esri.com Areas of concern defined by ZIP Code Water quality monitoring station and hydro buffers  

E-Print Network [OSTI]

on implementing best management practices on livestock farms and mitigating failing septic systems. [Nonpoint landowners whose land-use practices might be contributing to the impair- ment of water bodies in the Catawba and are generally carried off the land by storm water. According to the EPA, a TMDL "is the amount of a single

Short, Daniel

79

Neural Networks ensemble for quality monitoring , M. Noyel1  

E-Print Network [OSTI]

tools of Total Quality Management (TQM). The American Production and Inventory Control Society (APICS) defines Total Quality Management as "A management approach to long-term success through customerNeural Networks ensemble for quality monitoring P. Thomas1 , M. Noyel1 , M.C. Suhner1 , P

Boyer, Edmond

80

Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities  

SciTech Connect (OSTI)

This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs.

Nickels, J.M.

1991-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Sandia National Laboratories, California Quality Assurance Project Plan for Environmental Monitoring Program.  

SciTech Connect (OSTI)

This Quality Assurance Project Plan (QAPP) applies to the Environmental Monitoring Program at the Sandia National Laboratories/California. This QAPP follows DOE Quality Assurance Management System Guide for Use with 10 CFR 830 Subpart A, Quality Assurance Requirements, and DOE O 414.1C, Quality Assurance (DOE G 414.1-2A June 17, 2005). The Environmental Monitoring Program is located within the Environmental Operations Department. The Environmental Operations Department is responsible for ensuring that SNL/CA operations have minimal impact on the environment. The Department provides guidance to line organizations to help them comply with applicable environmental regulations and DOE orders. To fulfill its mission, the department has groups responsible for waste management; pollution prevention, air quality; environmental planning; hazardous materials management; and environmental monitoring. The Environmental Monitoring Program is responsible for ensuring that SNL/CA complies with all Federal, State, and local regulations and with DOE orders regarding the quality of wastewater and stormwater discharges. The Program monitors these discharges both visually and through effluent sampling. The Program ensures that activities at the SNL/CA site do not negatively impact the quality of surface waters in the vicinity, or those of the San Francisco Bay. The Program verifies that wastewater and stormwater discharges are in compliance with established standards and requirements. The Program is also responsible for compliance with groundwater monitoring, and underground and above ground storage tanks regulatory compliance. The Program prepares numerous reports, plans, permit applications, and other documents that demonstrate compliance.

Holland, Robert C.

2005-09-01T23:59:59.000Z

82

Reservoir vital signs monitoring, 1991: Physical and chemical characteristics of water and sediment  

SciTech Connect (OSTI)

In the second year of TVA's Reservoir Vital signs Monitoring program, physical/chemical measurements of water and sediment were made on fourteen TVA reservoirs (the nine mainstem Tennessee river reservoirs - Kentucky through Fort Loudoun and five tributary reservoirs - Cherokee, Douglas, Norris, Melton Hill and Tellico). In addition in 1991, limited water quality monitoring was initiated on ten tributary storage impoundments. The objective of the Vital Signs monitoring program is to assess the health or integrity of these aquatic ecosystems. Physical/chemical data collected in 1991 showed the water quality of the majority of TVA's reservoirs to be very good, but pointed out areas for improvement and further investigation.

Meinert, D.L.; Fehring, J.P.

1992-07-01T23:59:59.000Z

83

Factors affecting water quality in Cherokee Reservoir  

SciTech Connect (OSTI)

The purpose was to: (1) define reservoir problems related to water quality conditions; (2) identify the probable causes of these problems; and (3) recommend procedures for achieving needed reservoir water quality improvements. This report presents the project findings to date and suggests steps for upgrading the quality of Cherokee Reservoir. Section II presents background information on the characteristics of the basin, the reservoir, and the beneficial uses of the reservoir. Section III identifies the impacts of existing reservoir water quality on uses of the reservoir for water supply, fishery resources, recreation, and waste assimilation. Section IV presents an assessment of cause-effect relationships. The factors affecting water quality addressed in Section IV are: (1) reservoir thermal stratification and hydrodynamics; (2) dissolved oxygen depletion; (3) eutrophication; (4) toxic substances; and (5) reservoir fisheries. Section V presents a preliminary evaluation of alternatives for improving the quality of Cherokee Reservoir. Section VI presents preliminary conclusions and recommendations for developing and implementing a reservoir water quality management plan. 7 references, 22 figures, 21 tables.

Iwanski, M.L.; Higgins, J.M.; Kim, B.R.; Young, R.C.

1980-07-01T23:59:59.000Z

84

COURSE SYLLABUS WETLANDS AND WATER QUALITY  

E-Print Network [OSTI]

COURSE SYLLABUS WETLANDS AND WATER QUALITY SOS 5242 3 Credits I. COURSE DESCRIPTION: Introduction page of this syllabus to contact the instructor if you are not able to make it to an exam ­ prior

Ma, Lena

85

In-situ continuous water monitoring system  

DOE Patents [OSTI]

An in-situ continuous liquid monitoring system for continuously analyzing volatile components contained in a water source comprises: a carrier gas supply, an extraction container and a mass spectrometer. The carrier gas supply continuously supplies the carrier gas to the extraction container and is mixed with a water sample that is continuously drawn into the extraction container by the flow of carrier gas into the liquid directing device. The carrier gas continuously extracts the volatile components out of the water sample. The water sample is returned to the water source after the volatile components are extracted from it. The extracted volatile components and the carrier gas are delivered continuously to the mass spectrometer and the volatile components are continuously analyzed by the mass spectrometer. 2 figs.

Thompson, C.V.; Wise, M.B.

1998-03-31T23:59:59.000Z

86

Cerro Grande Fire Impact to Water Quality and Stream Flow near Los Alamos National Laboratory: Results of Four Years of Monitoring  

SciTech Connect (OSTI)

In May 2000, the Cerro Grande fire burned about 7400 acres of mixed conifer forest on the Los Alamos National Laboratory (LANL), and much of the 10,000 acres of mountainside draining onto LANL was severely burned. The resulting burned landscapes raised concerns of increased storm runoff and transport of contaminants by runoff in the canyons traversing LANL. The first storms after the fire produced runoff peaks that were more than 200 times greater than prefire levels. Total runoff volume for the year 2000 increased 50% over prefire years, despite a decline in total precipitation of 13% below normal and a general decrease in the number of monsoonal thunderstorms. The majority of runoff in 2000 occurred in the canyons at LANL south of Pueblo Canyon (70%), where the highest runoff volume occurred in Water Canyon and the peak discharge occurred in Pajarito Canyon. This report describes the observed effects of the Cerro Grande fire and related environmental impacts to watersheds at and near Los Alamos National Laboratory (LANL) for the first four runoff seasons after the fire, from 2000 through 2003. Spatial and temporal trends in radiological and chemical constituents that were identified as being associated with the Cerro Grande fire and those that were identified as being associated with historic LANL discharges are evaluated with regard to impacts to the Rio Grande and area reservoirs downstream of LANL. The results of environmental sampling performed by LANL, the New Mexico Environment Department (NMED), and U.S. Geological Survey (USGS) after the Cerro Grande fire are included in the evaluation. Effects are described for storm runoff, baseflow, stream sediments, and area regional reservoir sediment.

B.M. Gallaher; R.J. Koch

2004-09-15T23:59:59.000Z

87

Radionuclide Sensors for Subsurface Water Monitoring  

SciTech Connect (OSTI)

Contamination of the subsurface by radionuclides is a persistent and vexing problem for the Department of Energy. These radionuclides must be measured in field studies and monitoed in the long term when they cannot be removed. However, no radionuclide sensors existed for groundwater monitoring prior to this team's research under the EMSP program Detection of a and b decays from radionuclides in water is difficult due to their short ranges in condensed media.

Timothy DeVol

2006-06-30T23:59:59.000Z

88

Field Monitoring Protocol: Heat Pump Water Heaters  

SciTech Connect (OSTI)

This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

2013-02-01T23:59:59.000Z

89

Review of Wildfire Effects on Chemical Water Quality  

SciTech Connect (OSTI)

The Cerro Grande Fire of May 2000 burned almost 43,000 acres of forested land within the Pajarito Plateau watershed in northern New Mexico. Runoff events after the fire were monitored and sampled by Los Alamos National Laboratory. Changes in the composition of runoff water were noted when compared to runoff water composition of the previous 20 years. In order to understand the chemical water quality changes noted in runoff water after the Cerro Grande Fire, a summary of the reported effects of fire on runoff water chemistry and on soils that contribute to runoff water chemistry was compiled. The focus of this report is chemical water quality, so it does not address changes in sediment transport or water quantity associated with fires. Within the general inorganic parameters, increases of dissolved calcium, magnesium, nitrogen, phosphorus, and potassium and pH in runoff water have been observed as a result of fire. However, the dissolved sodium, carbon, and sulfate have been observed to increase and decrease as a result of fire. Metals have been much less studied, but manganese, copper, zinc, and cesium-137 have been observed to increase as a result of fire.

Kelly Bitner; Bruce Gallaher; Ken Mullen

2001-05-01T23:59:59.000Z

90

Water Quality and Water Law Headline UNL's Fifth Annual Water Law, Policy and  

E-Print Network [OSTI]

Water Quality and Water Law Headline UNL's Fifth Annual Water Law, Policy and Science Conference "Water Quality Challenges in the Great Plains" is the theme of this year's University of Nebraska-Lincoln Water, Law, Policy and Science conference. The fifth annual UNL conference is April 22 and 23 at Lincoln

Nebraska-Lincoln, University of

91

Coal conversion siting on coal mined lands: water quality issues  

SciTech Connect (OSTI)

The siting of new technology coal conversion facilities on land disturbed by coal mining results in both environmental benefits and unique water quality issues. Proximity to mining reduces transportation requirements and restores disrupted land to productive use. Uncertainties may exist, however, in both understanding the existing site environment and assessing the impact of the new technology. Oak Ridge National Laboratory is currently assessing the water-related impacts of proposed coal conversion facilities located in areas disturbed by surface and underground coal mining. Past mining practices, leaving highly permeable and unstable fill, may affect the design and quality of data from monitoring programs. Current mining and dewatering, or past underground mining may alter groundwater or surface water flow patterns or affect solid waste disposal stability. Potential acid-forming material influences the siting of waste disposal areas and the design of grading operations. These and other problems are considered in relation to the uncertainties and potentially unique problems inherent in developing new technologies.

Triegel, E.K.

1980-01-01T23:59:59.000Z

92

Texas Stream Team: Ambassadors for Texas water quality  

E-Print Network [OSTI]

tx H2O | pg. 23 Story by Kathy Wythe Ambassadors for Texas water Roger Miranda of Texas Commission on Environmental Quality volunteers as a certified trainer for Texas Stream Team. Photo by Robert Sams, Texas Stream Team Texas stream... team continued tx H2O | pg. 24 An African proverb says it takes a village to raise a child. However, the Texas Stream Team would say it takes a group of citizens to monitor Texas waters. The Texas Stream Team, formerly Texas Watch, is based...

Wythe, Kathy

2010-01-01T23:59:59.000Z

93

Optical monitor for water vapor concentration  

DOE Patents [OSTI]

A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma.

Kebabian, Paul (Acton, MA)

1998-01-01T23:59:59.000Z

94

Impacts of Water Quality on Residential Water Heating Equipment  

SciTech Connect (OSTI)

Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

Widder, Sarah H.; Baechler, Michael C.

2013-11-01T23:59:59.000Z

95

FAPRI-UMC Report #01-07 Estimating Water Quality,  

E-Print Network [OSTI]

Carbon and Carbon Sequestration...................................10 CRP EffectsFAPRI-UMC Report #01-07 Estimating Water Quality, Air Quality, and Soil Carbon Benefits Quality, Air Quality, and Soil Carbon Benefits of the Conservation Reserve Program FAPRI-UMC Report #01

96

Greenland Meadows LID Case Study: Water Quality  

E-Print Network [OSTI]

Greenland Meadows LID Case Study: Water Quality Greenland Meadows is a retail shopping center built in 2008 by Newton, Mass.- based New England Development in Greenland, N.H. The development is located Development and Community Decisions can be found at http://www.unh.edu/unhsc/ftl/ Greenland Meadows features

97

Southern Region Water Quality Coordination Project  

E-Print Network [OSTI]

an existing collaborative process through which new and existing technologies and management systems Committee (SRWQPC) promotes the development and delivery of effective management systems that can be adaptedSouthern Region Water Quality Coordination Project September 14, 2004 to June 1, 2005 Progress

98

120 Ground Water Monitoring & Remediation 32, no. 1/ Winter 2012/pages 120130 NGWA.org Ground Water Monitoring & Remediation  

E-Print Network [OSTI]

120 Ground Water Monitoring & Remediation 32, no. 1/ Winter 2012/pages 120­130 NGWA.org Ground Water Monitoring & Remediation © 2011, National Ground Water Association. Published 2011. This article known as emerging contaminants (ECs) to surrounding groundwater and surface water. ECs consist

99

Non-intrusive water utility monitoring and free-space load monitoring  

E-Print Network [OSTI]

This work presents a non-intrusive, single-point sensing scheme to monitor the water usage for various loads on a water utility pipe network through the vibration of a pipe near the water intake source. Experiments with ...

Neuman, Sabrina M

2011-01-01T23:59:59.000Z

100

Real-Time Water Quality Management in the Grassland Water District  

SciTech Connect (OSTI)

The purpose of the research project was to advance the concept of real-time water quality management in the San Joaquin Basin by developing an application to drainage of seasonal wetlands in the Grassland Water District. Real-time water quality management is defined as the coordination of reservoir releases, return flows and river diversions to improve water quality conditions in the San Joaquin River and ensure compliance with State water quality objectives. Real-time water quality management is achieved through information exchange and cooperation between shakeholders who contribute or withdraw flow and salt load to or from the San Joaquin River. This project complements a larger scale project that was undertaken by members of the Water Quality Subcommittee of the San Joaquin River Management Program (SJRMP) and which produced forecasts of flow, salt load and San Joaquin River assimilative capacity between 1999 and 2003. These forecasts can help those entities exporting salt load to the River to develop salt load targets as a mechanism for improving compliance with salinity objectives. The mass balance model developed by this project is the decision support tool that helps to establish these salt load targets. A second important outcome of this project was the development and application of a methodology for assessing potential impacts of real-time wetland salinity management. Drawdown schedules are typically tied to weather conditions and are optimized in traditional practices to maximize food sources for over-wintering wildfowl as well as providing a biological control (through germination temperature) of undesirable weeds that compete with the more proteinaceous moist soil plants such as swamp timothy, watergrass and smartweed. This methodology combines high resolution remote sensing, ground-truthing vegetation surveys using established survey protocols and soil salinity mapping using rapid, automated electromagnetic sensor technology. This survey methodology could be complemented with biological surveys of bird use and invertebrates to produce a robust long-term monitoring strategy for habitat health and sustainability.

Quinn, Nigel W.T.; Hanna, W. Mark; Hanlon, Jeremy S.; Burns, Josphine R.; Taylor, Christophe M.; Marciochi, Don; Lower, Scott; Woodruff, Veronica; Wright, Diane; Poole, Tim

2004-12-10T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Questa Baseline and Pre-Mining Ground-Water Quality Investigation. 3. Historical Ground-Water  

E-Print Network [OSTI]

............................................................................................................................................................... 9 Mine history and ground-water development ....................................................................................................................................................... 11 Ground-water quality database.......................................................................................................................................................... 29 Compilation of complete database

102

Sensor Networks for Monitoring and Control of Water Distribution Systems  

E-Print Network [OSTI]

Water distribution systems present a significant challenge for structural monitoring. They comprise a complex network of pipelines buried underground that are relatively inaccessible. Maintaining the integrity of these ...

Whittle, Andrew

103

Optimal water quality management in surface water systems and energy recovery in water distribution networks.  

E-Print Network [OSTI]

??Two of the most important environmental challenges in the 21st century are to protect the quality of fresh water resources and to utilize renewable energy… (more)

Telci, Ilker Tonguc

2012-01-01T23:59:59.000Z

104

Water Quality, Resources and Technology | Argonne National Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Quality, Resources and Technology Water is an increasingly valuable natural resource. By identifying typical sources and distribution of microbial communities in waterways,...

105

Implementation and Testing of Water Quality Lucy Cheng  

E-Print Network [OSTI]

Student Fellowship Program #12;1 BACKGROUND In Arizona, due the market development of realtime water quality sensors. These sensors are convenient in detecting aspects of the sensors in their implementations, have not been well studied. The water quality sensors

Fay, Noah

106

Geothermal Power Plants — Meeting Water Quality and Conservation Standards  

Broader source: Energy.gov [DOE]

U.S. geothermal power plants can easily meet federal, state, and local water quality and conservation standards.

107

Reservoir vital signs monitoring, 1991: Physical and chemical characteristics of water and sediment  

SciTech Connect (OSTI)

In the second year of TVA`s Reservoir Vital signs Monitoring program, physical/chemical measurements of water and sediment were made on fourteen TVA reservoirs (the nine mainstem Tennessee river reservoirs - Kentucky through Fort Loudoun and five tributary reservoirs - Cherokee, Douglas, Norris, Melton Hill and Tellico). In addition in 1991, limited water quality monitoring was initiated on ten tributary storage impoundments. The objective of the Vital Signs monitoring program is to assess the health or integrity of these aquatic ecosystems. Physical/chemical data collected in 1991 showed the water quality of the majority of TVA`s reservoirs to be very good, but pointed out areas for improvement and further investigation.

Meinert, D.L.; Fehring, J.P.

1992-07-01T23:59:59.000Z

108

EECLP Webinar #2: Quality Assurance and Evaluation Monitoring Verification-- Text Version  

Broader source: Energy.gov [DOE]

Below is the text version of the EECLP Webinar #2: Quality Assurance and Evaluation Monitoring Verification, presented in December 2014.

109

Abstract--A physically based, spatially-distributed water quality model is being developed to simulate spatial and temporal  

E-Print Network [OSTI]

Abstract--A physically based, spatially-distributed water quality model is being developed, and water quality were used to estimate nonpoint source loading potential in the study watersheds. Animal to the monitored total phosphorous load indicates that both point and nonpoint sources are major contributors

110

La Jolla Children's Pool Beach Management and Water Quality Improvement Project  

E-Print Network [OSTI]

POOL BEACH MANAGEMENT AND WATER QUALITY IMPROVEMENT PROJECTPool Beach Management and Water Quality Improvements ProjectPool Beach Management and Water Quality Improvements Project

Elwany, Hany; Flick, Reinhard; Nichols, Jean; Lindquist, Anne-Lise

1998-01-01T23:59:59.000Z

111

Grass Upland Water Quality Wednesday November 21st 2007  

E-Print Network [OSTI]

Grass Upland Water Quality Workshop Wednesday November 21st 2007 Water Quality in the Uplands financial support to farming could protect rural economies while reducing this damage to water. Help farmers · Unnatural spates ­ potential downstream flooding little water retention on land uneven flows lack

Quinton, John

112

Water Quality: Its Relationship to Livestock  

E-Print Network [OSTI]

concen- trations. Examples are iron, copper, cobalt, zinc, iodide and manganese. These elements do not seem to accumu- late in meat or milk to the extent that they would cause a problem. The most common water quality problems affecting livestock... 0.002 0.01 0.01 Molybdenum Not established No limit Nickel 1.0 Nitrate-N 10.0 100 300 Nitrite-N 10 10 Salinity See Table 2 Selenium 0.01 Silver 0.05 Sulfate e 250 Total Dissolved Solids e 500 Vanadium 0.1 1.0 Zinc 5.0 25...

Faries Jr., Floron C.; Sweeten, John M.; Reagor, John C.

1998-06-30T23:59:59.000Z

113

Operating Experience Review of Tritium-in-Water Monitors  

SciTech Connect (OSTI)

Monitoring tritium facility and fusion experiment effluent streams is an environmental safety requirement. This paper presents data on the operating experience of a solid scintillant monitor for tritium in effluent water. Operating experiences were used to calculate an average monitor failure rate of 4E-05/hour for failure to function. Maintenance experiences were examined to find the active repair time for this type of monitor, which varied from 22 minutes for filter replacement to 11 days of downtime while waiting for spare parts to arrive on site. These data support planning for monitor use; the number of monitors needed, allocating technician time for maintenance, inventories of spare parts, and other issues.

S. A. Bruyere; L. C. Cadwallader

2011-09-01T23:59:59.000Z

114

Increased Mercury Bioaccumulation Follows Water Quality Improvement  

SciTech Connect (OSTI)

Changes in physical and chemical characteristics of aquatic habitats made to reduce or eliminate ecological risks can sometimes have unforeseen consequences. Environmental management activities on the U.S. Dept. of Energy reservation in Oak Ridge, Tennessee,have succeeded in improving water quality in streams impacted by discharges fi-om industrial facilities and waste disposal sites. The diversity and abundance of pollution-sensitive components of the benthic macroinvertebrate communities of three streams improved after new waste treatment systems or remedial actions reduced inputs of various toxic chemicals. Two of the streams were known to be mercury-contaminated from historical spills and waste disposal practices. Waterborne mercury concentrations in the third were typical of uncontaminated systems. In each case, concentrations of mercury in fish, or the apparent biological availability of mercury increased over the period during which ecological metrics indicated improved water quality. In the system where waterborne mercury concentrations were at background levels, increased mercury bioaccumulation was probably a result of reduced aqueous selenium concentrations; however, the mechanisms for increased mercury accumulation in the other two streams remain under investigation. In each of the three systems, reduced inputs of metals and inorganic anions was followed by improvements in the health of aquatic invertebrate communities. However, this reduction in risk to aquatic invertebrates was accompanied by increased risk to humans and piscivorous wildlife related to increased mercury concentrations in fish.

Bogle, M.A.; Peterson, M.J.; Smith, J.G.; Southworth, G.R.

1999-09-15T23:59:59.000Z

115

Research SummaryForest Research Monitoring and evaluating Quality of Life for CSR 07  

E-Print Network [OSTI]

(Target 1), and increases management activities), quality of experience and personal in visitsResearch SummaryForest Research Monitoring and evaluating Quality of Life for CSR 07 As part corporate Quality of Life (QoL) targets, giving rise to the Monitoring and Evaluating Quality of Life

116

On-Farm Soil Monitoring for Water  

E-Print Network [OSTI]

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Soil quality and soil management resources the air which helps build soil organic matter and tilth, and sustains the soil resource for future generations and other species. Improving and protecting soil quality can help support sustainable crop

Holland, Jeffrey

117

Impact of alfalfa on soil and water quality  

SciTech Connect (OSTI)

Dominance of row crop agriculture in rolling landscapes of western and Southwestern Minnesota is identified as a primary, non-point source of sediments and associated pollutants reaching the Minnesota River. Currently as a biomass energy project, alfalfa is being promoted in western Minnesota to harvest the leaves for animal feed and stems to generate electricity. As a perennial, leguminous crop grown with minimum inputs, introduction of alfalfa in row cropped lands has potential to improve both in-situ soil productivity and downstream water quality. A field study was initiated in 1996 to compare the volume of runoff and pollutants coming from alfalfa an com-soybean fields in western Minnesota. Two pair of alfalfa and corn-soybean watersheds were instrumented at Morris in the Fall of 1996 to measure rainfall, runoff, and sample water for sediment load, phosphorus, nitrogen, biochemical oxygen demand, and chemical oxygen demand. Simulated rainfall-runoff experiments were conducted on an existing crop rotation - input management study plots at Lamberton to evaluate soil quality effects of the inclusion of alfalfa in a corn-soybean rotation under manure and fertilization management schemes. Alfalfa soil water use as a function of frequency of harvest was also monitored at Morris to evaluate the effect of cutting schedule on soil water use. During the growing season of 1997, alfalfa under a two-cut management scheme used about 25-mm (an inch) more soil water than under a three-cut schedule. The mean differences between the treatments were not significant. The conclusions drawn in this report come from analysis of data collected during one winter-summer hydrologic and crop management cycle. Continued observations through a period of at least 3-5 years is recommended to improve the instrumentation robustness and discern the variability due to climate, soil, and crop management factors.

Sharma, P.; Moncrief, J.; Gupta, S.

1997-10-30T23:59:59.000Z

118

Enhanced monitor system for water protection  

DOE Patents [OSTI]

An automatic, self-contained device for detecting toxic agents in a water supply includes an analyzer for detecting at least one toxic agent in a water sample, introducing a means for introducing a water sample into the analyzer and discharging the water sample from the analyzer, holding means for holding a water sample for a pre-selected period of time before the water sample is introduced into the analyzer, and an electronics package that analyzes raw data from the analyzer and emits a signal indicating the presence of at least one toxic agent in the water sample.

Hill, David E. (Knoxville, TN) [Knoxville, TN; Rodriquez, Jr., Miguel [Oak Ridge, TN; Greenbaum, Elias (Knoxville, TN) [Knoxville, TN

2009-09-22T23:59:59.000Z

119

SEASONAL RECLAIMED WATER QUALITY; AN ASSESSMENT OFQUALITY; AN ASSESSMENT OF  

E-Print Network [OSTI]

and disinfect anyy microorganisms that may be present The majority of Recycled water produced in ArizonaSEASONAL RECLAIMED WATER QUALITY; AN ASSESSMENT OFQUALITY; AN ASSESSMENT OF BIOLOGICAL VARIABILITY Ch h M R k Ph D W t Q lit S i li tChannah M. Rock, Ph.D., Water Quality Specialist James Walworth, Ph

Fay, Noah

120

Water Quality for Livestock Max Irsik DVM, MAB  

E-Print Network [OSTI]

Water Quality for Livestock Max Irsik DVM, MAB Beef Cattle Extension Veterinarian University of Florida College of Veterinary Medicine Water is an essential nutrient for humans and livestock and drinking water is the primary source of water for most cattle. The most important aspect of water

Watson, Craig A.

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Monitoring SERC Technologies: On-Demand Tankless Water Heaters  

Broader source: Energy.gov [DOE]

A webinar by Ethan MacCormick, VP for Services to Energy Businesses at Performance Systems Development, about On-Demand Tankless Water Heaters and how to properly monitor the installation.

122

Chapter 10 Water Quality Standards (Kentucky)  

Broader source: Energy.gov [DOE]

This administrative regulation establishes procedures to protect the surface waters of the Commonwealth, and thus protect water resources. It states the designated uses of surface water and...

123

2009 Site environmental report5-Water Quality  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities-N Real Time Monitor for Radioactivity, pH, Conductivity Blower Building Abandoned Sand Filter Beds

124

An Approach for QoS Measurements in IP Multicast Networks MQM -Multicast Quality Monitor  

E-Print Network [OSTI]

An Approach for QoS Measurements in IP Multicast Networks MQM - Multicast Quality Monitor Falko@acm.org Abstract MQM - Multicast Quality Monitor represents a new approach to measure QoS within an IP multicast which builds a very basis for the measurements. Keywords IP Multicast, Quality of Service, IP

Breu, Ruth

125

Reservoir vital signs monitoring, 1990: Physical and chemical characteristics of water and sediments  

SciTech Connect (OSTI)

As part of Tennessee Valley Authority`s (TVA`s) Reservoir Vital Signs Monitoring program, physical/chemical measurements of water and sediment were made in 1990 on twelve TVA reservoirs (the nine main steam Tennessee river reservoirs - Kentucky through Fort Loudoun and three major tributary reservoirs - Cherokee, Douglas, and Norris). The objective of this monitoring program is to assess the health or integrity of these aquatic ecosystems. The physical/chemical water quality data collected in 1990 showed the water quality of these reservoirs to be very good. However, hypolimnetic anoxia during the summer months in Watts bars, Douglas, and Cherokee reservoir continues to be a concern. High concentrations of nutrients were measured in the transition zones of Cherokee and Douglas reservoirs, resulting in highly productive and eutrophic conditions in the transition zones of these reservoirs. Fecal coliform organisms were frequently detected in the forebay area of Guntersville reservoir, and higher than expected ammonia nitrogen concentrations were found at the transition zone of Wheeler reservoir. Elevated concentrations of mercury were found in Pickwick and Watts bar reservoir sediment, and high lead concentrations were found in a sediment sample collected from Guntersville reservoir. A TVA Reservoir Water Quality Index (RWQI) was developed and used to summarize water quality conditions on a scale from 0 (worst) to 100 (best).

Meinert, D.L.

1991-05-01T23:59:59.000Z

126

Reservoir vital signs monitoring, 1990: Physical and chemical characteristics of water and sediments  

SciTech Connect (OSTI)

As part of Tennessee Valley Authority's (TVA's) Reservoir Vital Signs Monitoring program, physical/chemical measurements of water and sediment were made in 1990 on twelve TVA reservoirs (the nine main steam Tennessee river reservoirs - Kentucky through Fort Loudoun and three major tributary reservoirs - Cherokee, Douglas, and Norris). The objective of this monitoring program is to assess the health or integrity of these aquatic ecosystems. The physical/chemical water quality data collected in 1990 showed the water quality of these reservoirs to be very good. However, hypolimnetic anoxia during the summer months in Watts bars, Douglas, and Cherokee reservoir continues to be a concern. High concentrations of nutrients were measured in the transition zones of Cherokee and Douglas reservoirs, resulting in highly productive and eutrophic conditions in the transition zones of these reservoirs. Fecal coliform organisms were frequently detected in the forebay area of Guntersville reservoir, and higher than expected ammonia nitrogen concentrations were found at the transition zone of Wheeler reservoir. Elevated concentrations of mercury were found in Pickwick and Watts bar reservoir sediment, and high lead concentrations were found in a sediment sample collected from Guntersville reservoir. A TVA Reservoir Water Quality Index (RWQI) was developed and used to summarize water quality conditions on a scale from 0 (worst) to 100 (best).

Meinert, D.L.

1991-05-01T23:59:59.000Z

127

An Economic Impact Analysis of DC Drinking Water Quality  

E-Print Network [OSTI]

An Economic Impact Analysis of DC Drinking Water Quality Annual Progress Report for FY 2005 In January 2004, District of Columbia residents learned the drinking water supplied by the D.C. Water immediately responded by forming the Interagency Task Force on Lead in Drinking Water (The Task Force

District of Columbia, University of the

128

Water quality and business aspects of sachet-vended water in Tamale, Ghana .  

E-Print Network [OSTI]

??Microbial water quality analyses were conducted on 15 samples of factory-produced sachet water and 15 samples of hand-tied sachet water, sold in Tamale, Ghana. The… (more)

Okioga, Teshamulwa (Teshamulwa Irene)

2007-01-01T23:59:59.000Z

129

Water quality and business aspects of sachet-vended water in Tamale, Ghana  

E-Print Network [OSTI]

Microbial water quality analyses were conducted on 15 samples of factory-produced sachet water and 15 samples of hand-tied sachet water, sold in Tamale, Ghana. The tests included the membrane filtration (MF) test using ...

Okioga, Teshamulwa (Teshamulwa Irene)

2007-01-01T23:59:59.000Z

130

Report Concerns: Storm Water Quality Hotline  

E-Print Network [OSTI]

by Joanne Yee, Storm Water Management Program Intern for the UCSC Storm Water Management Program. Like us on Facebook at UCSC Storm Water Management Program Contact us at: cleanwater@ucsc.edu (831) 459, Volume 5, Number 1 Learn more about the UCSC Storm Water Management Program and UCSC Storm Water

California at Santa Cruz, University of

131

Report Concerns: Storm Water Quality Hotline  

E-Print Network [OSTI]

by Joanne Yee, Storm Water Management Program Intern for the UCSC Storm Water Management Program. Like us on Facebook at UC Santa Cruz Storm Water Management Program Contact us at: cleanwater@ucsc.edu (831) 459, Volume 5, Number 1 Learn more about the UCSC Storm Water Management Program and UCSC Storm Water

California at Santa Cruz, University of

132

E-Print Network 3.0 - adult abundance monitoring Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WATER QUALITY... -FIELD RECEIVING WATER MONITORING OF A BENTHIC COMMUNITY NEAR THE PALO ALTO WATER QUALITY CONTROL PLANT IN SOUTH... ... Source: US Department of the Interior, US...

133

Water Quality and Quantity Concerns Population growth, increasing water demands,  

E-Print Network [OSTI]

systems, private water well screening, and soil nutrient management. Water conservation programs of Agri, efficient use, sustainable practices, watershed management and environmental stewardship. Through 660 and utilizing water-conservation practices will be essential to sustain the state's water supply

134

E-Print Network 3.0 - air quality monitoring Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Trent University Environmental and Resource Studies Program Summary: Chemistry 2 Sep. 22 Air Pollution Overview The Atmosphere Air Quality Monitoring Networks 1 3 Sep. 29......

135

Surface Water Quality Standards (New Jersey)  

Broader source: Energy.gov [DOE]

These standards establish the designated uses and antidegradation categories of the State's surface waters, classify surface waters based on those uses (i.e., stream classifications), and specify...

136

Implantation of an on-line quality process monitoring Mlanie NOYEL, Philippe THOMAS, Patrick  

E-Print Network [OSTI]

this quality monitoring system and to correct neural classifier, a control charts is used to highlight]. This importance is underlined by the huge of methods to manage this quality. One of them is the SPC (Statistical

Paris-Sud XI, Université de

137

LHCb RICH Online-Monitor and Data-Quality  

E-Print Network [OSTI]

The LHCb experiment at the LHC (CERN) has been optimised for high precision measurements of the beauty quark sector. Its main objective is to precisely determine and over-constrain the parameters of the CKM mixing matrix, and to search for further sources of CP violation and new physics beyond the Standard Model in rare B-decays. Efficient particle identification at high purities over a wide momentum range from around 1 to ~100GeV/c is vital to many LHCb analyses. Central to the LHCb particle identification strategy are two Ring Imaging CHerenkov (RICH) detectors which use Silica Aerogel and C4F10 and CF4 gas radiators. A rigorous quality control scheme is being developed to insure that the data recorded by the RICH detector meets the stringent requirements of the physics analyses. The talk summarises the LHCb RICH online monitoring and data-quality strategy. Multiple dedicated algorithms are deployed to detect any potential issue already during data-taking ranging from integrity checks, mis-alignments to cha...

Kerzel, U

2009-01-01T23:59:59.000Z

138

Report Concerns: Storm Water Quality Hotline  

E-Print Network [OSTI]

is imple- menting the Storm Water Manage- ment Plan (SWMP), which identifies many Best Management Practices Management Program Intern for the UCSC Storm Water Management Program. Contact us at: cleanwater@ucsc.edu Like us on Facebook at UCSC Storm Water Management Program (831) 459--4520 In this Issue: Storm Water

California at Santa Cruz, University of

139

Solving Water Quality Problems in the Home  

E-Print Network [OSTI]

If your drinking water comes from a private water well, there are certain procedures you can follow to make sure the water is safe. This publication explains how to get your water tested and, if treatment is necessary, to select the correct...

Dozier, Monty; McFarland, Mark L.

2004-02-20T23:59:59.000Z

140

Storm Water Quality Please report any concerns,  

E-Print Network [OSTI]

) 4594520 http://cleanwater.ucsc.edu Volunteer and intern with the Storm Water Management Program the Campus Stewardship Program Like us on Facebook at UC Santa Cruz Storm Water Management Program Learn more about the UCSC Storm Water Management Program and UCSC Storm Water Management Plan

California at Santa Cruz, University of

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

The Quality of Our Nation's Waters Factors Affecting Public-Supply-Well  

E-Print Network [OSTI]

, and local information needs and decisions related to water-quality management and policy (httpThe Quality of Our Nation's Waters Factors Affecting Public-Supply-Well Vulnerability to Contamination: Understanding Observed Water Quality and Anticipating Future Water Quality National Water-Quality

142

Name ___________________________________________ The laboratory website provides access to multiple water use and water quality publications.  

E-Print Network [OSTI]

to lower water pH) 4. R + Metals + Titration for Drip Irrigation $42.50 per sample 5. R + Metals + Heavy water use and water quality publications. Soil, Water and Forage Testing Laboratory Department of Soil and Crop Sciences Texas AgriLife Extension Service W14 WATER SAMPLE INFORMATION FORM Please submit

143

COSTS OF WATER TREATMENT DUE TO DIMINISHED WATER QUALITY: A CASE STUDY IN TEXAS  

E-Print Network [OSTI]

COSTS OF WATER TREATMENT DUE TO DIMINISHED WATER QUALITY: A CASE STUDY IN TEXAS David Dearmont and Resources Portland State University P O Box 751 Portland OR 97207-0751 October, 1997 Draft of paper in Water Resources Research, 34(4), 849-854, 1998. #12;2 CHEMICAL COSTS OF WATER TREATMENT DUE TO DIMINISHED WATER

McCarl, Bruce A.

144

Air quality monitoring and modelling techniques for street canyons: the Paris  

E-Print Network [OSTI]

2000-37 Air quality monitoring and modelling techniques for street canyons: the Paris experience S of developing efficient air quality monitoring and modelling methodologies to cover the needs of public health, published in "Air Pollution Conference 2000, Cambridge : United Kingdom (2000)" #12;1 Introduction In recent

Paris-Sud XI, Université de

145

FINAL REPORT FOR TRITIUM WATER MONITOR  

SciTech Connect (OSTI)

The objective of this Plant Directed Research and Demonstration (PDRD) task was to develop a system to safetly analyze tritium in moisture collected from glovebox atmospheres in the Savannah River Site (SRS) Tritium Facility. In order to minimize potential radiation exposures that could occur in handling and diluting high-tritium-content water, SRS sought alternatives to liquid-scintillation counting. The proposed system determines tritium concentrations by measuring Bremsstrahlung radiation induced by low-energy beta interactions in liquid samples. Results show that, after a short counting period (30 seconds), detection limits are three orders of magnitude below the described concentration of tritiated water in the zeolite beds. Additionally, this report covers the analysis of process samples and the investigation of several cell window materials including beryllium, aluminum, and copper. Final tests reveal that alternate window materials and thicknesses can be used to obtain useful results. In particular, a window of stainless steel of moderate thickness (0.3 cm) can be used for counting relatively high levels of tritium.

Sigg, R.; Ferguson, B.; DiPrete, D.

2011-04-25T23:59:59.000Z

146

Water Quality Guide for Livestock and Poultry  

E-Print Network [OSTI]

This publication discusses some of the most common contaminants in the drinking water of livestock and poultry. A table lists the Maximum Contaminant Level of some harmful substances....

Mukhtar, Saqib

1998-09-30T23:59:59.000Z

147

Geothermal Direct-Use — Meeting Water Quality Standards  

Broader source: Energy.gov [DOE]

Geothermal direct-use applications—such as greenhouses, district and space heating, and aquaculture—can easily meet local and federal water quality standards, which help protect our environment.

148

Impervious Areas: Examining the Undermining Effects on Surface Water Quality  

E-Print Network [OSTI]

of the classification. The overall accuracy was 85%, and the kappa coefficient was 0.80. Additionally, field sampling and chemical analysis techniques were used to examine the relationship between impervious surfaces and water quality in a rainfall simulation parking...

Young, De'Etra Jenra

2012-02-14T23:59:59.000Z

149

COLLABORATIVE INVESTIGATIONS OF WATER QUALITY POLLUTION PATTERNS: WORKING WITH  

E-Print Network [OSTI]

and Environmental Management Title of Research Project: Collaborative Investigations of Water Quality Pollution: Chair: Jennifer Silver Phd Candidate in Resource and Environmental Management (REM) ___________________________________________ Dr. Evelyn Pinkerton Senior Supervisor Professor of Resource and Environmental Management, SFU

150

Challenges for Water Quality Best Management Practices Andrew Sharpley  

E-Print Network [OSTI]

Challenges for Water Quality Best Management Practices Andrew Sharpley Department of Crop, Soil and Environmental Sciences, University of Arkansas, Fayetteville, AR Agricultural Best Management Practices (BMPs, basing fertilizer applications on soil test recommendations, and transportation from surplus to deficit

151

New Mexico Surface Water Quality Bureau Federal Dredge and Fill...  

Open Energy Info (EERE)

New Mexico Surface Water Quality Bureau Federal Dredge and Fill Permits webpage Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site: New Mexico Surface...

152

Antineutrino monitoring for the Iranian heavy water reactor  

E-Print Network [OSTI]

In this note we discuss the potential application of antineutrino monitoring to the Iranian heavy water reactor at Arak, the IR-40, as a non-proliferation measure. We demonstrate that an above ground detector positioned right outside the IR-40 reactor building could meet and in some cases significantly exceed the verification goals identified by IAEA for plutonium production or diversion from declared inventories. In addition to monitoring the reactor during operation, observing antineutrino emissions from long-lived fission products could also allow monitoring the reactor when it is shutdown. Antineutrino monitoring could also be used to distinguish different levels of fuel enrichment. Most importantly, these capabilities would not require a complete reactor operational history and could provide a means to re-establish continuity of knowledge in safeguards conclusions should this become necessary.

Christensen, Eric; Jaffke, Patrick; Shea, Thomas

2014-01-01T23:59:59.000Z

153

Antineutrino monitoring for the Iranian heavy water reactor  

E-Print Network [OSTI]

In this note we discuss the potential application of antineutrino monitoring to the Iranian heavy water reactor at Arak, the IR-40, as a non-proliferation measure. We demonstrate that an above ground detector positioned right outside the IR-40 reactor building could meet and in some cases significantly exceed the verification goals identified by IAEA for plutonium production or diversion from declared inventories. In addition to monitoring the reactor during operation, observing antineutrino emissions from long-lived fission products could also allow monitoring the reactor when it is shutdown. Antineutrino monitoring could also be used to distinguish different levels of fuel enrichment. Most importantly, these capabilities would not require a complete reactor operational history and could provide a means to re-establish continuity of knowledge in safeguards conclusions should this become necessary.

Eric Christensen; Patrick Huber; Patrick Jaffke; Thomas Shea

2014-03-27T23:59:59.000Z

154

Reservoir/River System Reliability Considering Water Rights and Water Quality  

E-Print Network [OSTI]

Effective management of the highly variable water resources of a river basin requires an understanding of the amount of suitable quality water that can be provided under various conditions within institutional constraints. Although much research has...

Wurbs, Ralph A.; Sanchez-Torres, Gerardo; Dunn, David D.

155

Regulations Establishing Water Quality Standards for Surface Water of the State of Arkansas (Arkansas)  

Broader source: Energy.gov [DOE]

The Regulations Establishing Water Quality Standards are established pursuant to the provisions of Subchapter 2 of the Arkansas Water and Air Pollution Control Act (Act 472 of the Acts of Arkansas...

156

Water Scarcity, Climate Change, and Water Quality: Three Economic Essays  

E-Print Network [OSTI]

percent being used for municipal purposes, 54 percent for irrigation, 10 percent for industry, and the rest for steam electric and livestock (see Figure 2-1). Ground water accounts for approximately 60 percent of water used, and 79 percent of ground............................................................................................. 125 3.3.4 Regression results ......................................................................... 125 3.3.5 Climate change impacts on water supply...................................... 129 3.4 Climate change impact on municipal water demand...

Cai, Yongxia

2010-07-14T23:59:59.000Z

157

Water Quality Modeling Hydraulics and Hydrology Group  

E-Print Network [OSTI]

: ­ Streamflows ­ Lake basin ­ Meteorology (wind/sun/precip...) · Outputs: ­ Vertical Temperature distribution ­ E. Coli · Temperature changes ­ Long term and short term · Lake circulation ­ Lake circulation ­ Outputs: · Oxygen distribution in water column · Nutrient distribution in water column (N

158

Water Quality Impacts of Bunker Silos  

E-Print Network [OSTI]

and water) as well as feed particles and soil transported by flow. #12;Management and Disposal Options 1 Engineering Department UW ­ Madison with assistance from Larry D. Geohring Biological and Environmental Engineering Department Cornell University Area Soil and Soil & Water Meetings November 28 ­ December 7, 2006

Balser, Teri C.

159

Water Quality and Hydrologic Performance of a Porous Asphalt Pavement as a Storm-Water  

E-Print Network [OSTI]

examined the functionality of a porous pavement storm-water management system in coastal New Hampshire headings: Stormwater management; Runoff; Porous media; Pavements; Cold regions; Best Management Practice; Water quality; Water treatment. Author keywords: Storm-water management; Runoff; Porous pavements; Cold

160

Drinking water treatment and distribution systems must comply with US EPA water quality regula-  

E-Print Network [OSTI]

Drinking water treatment and distribution systems must comply with US EPA water quality regula trihalomethanes (THMs). Drinking water providers do frequent, costly testing for THMs. Field real-time sensors PROJECT GOALS The goal of this project was to bring a team of experts in drinking water, polymers

Fay, Noah

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Current and Long-Term Effects of Delta Water Quality on Drinking Water Treatment Costs from Disinfection Byproduct Formation  

E-Print Network [OSTI]

for protecting public drinking water (CALFED 2000), are alsobest management options for drinking water sourced from theDelta Authority. 2004. Drinking water quality program multi-

Chen, Wei-Hsiang; Haunschild, Kristine; Lund, Jay R.; Fleenor, William E.

2010-01-01T23:59:59.000Z

162

E-Print Network 3.0 - applying water quality Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Powered by Explorit Topic List Advanced Search Sample search results for: applying water quality Page: << < 1 2 3 4 5 > >> 1 Best Management Practices Water Quality Summary:...

163

Youth Water Camp: Ward County 4-H program educates students about water conservation, quality  

E-Print Network [OSTI]

tx H2O | pg. 24 A plant chemist directs Water Camp youth in basic water analysis at a local power plant during a tour. Story by Danielle Supercinski Ward County 4-H program educates students about water conservation, quality In January... 1991, a committee of the Texas Agricultural Extension Service (now Texas AgriLife Extension Service) and Upper Pecos Soil and Water Conservation District person- nel met on the development of a 4-H water camp educating youth on water issues...

Supercinski, Danielle

2008-01-01T23:59:59.000Z

164

Water Quality Modeling in Kranji Catchment  

E-Print Network [OSTI]

This thesis describes the process and results of applying the Soil and Water Assessment Tool (SWAT) to characterize bacterial fate and transport in the Kranji Catchment of Singapore. The goal of this process is to predict ...

Granger, Erika C

2010-01-01T23:59:59.000Z

165

Annual water quality data report for the Waste Isolation Pilot Plant  

SciTech Connect (OSTI)

This is the fourth Annual Water Quality Data Report for the Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico. The WIPP project is operated by the United States Department of Energy (DOE) for the purpose of providing a research and development facility to demonstrate the safe disposal of transuranic radioactive wastes generated by the defense activities of the United States Government. This report presents water quality data collected from January 1988 through December 1988 from 16 designated pre-operational (WIPP facility) monitoring wells, two additional wells, and 10 privately-owned wells in the vicinity of the WIPP. Additionally, water samples were collected from the Air Intake Shaft during shaft construction activities at the WIPP. This report lists pertinent information regarding the monitoring wells sampled, sampling zone, dates pumped, and types of samples collected during 1988. Comparative data from previous samplings of all wells can be found in Uhland and Randall (1986), Uhland et al. (1987), Randall et al. (1988), as well as in this report. The data reported by the Water Quality Sampling Program in this and previous reports indicate that serial sampling is a very useful tool in determining sample representativeness from wells in the WIPP vicinity. Serial sample field chemistry data are demonstrated to be highly accurate and precise as indicated by the excellent overall average percent spike recovery values and low RPD values reported for the sampling events. Serial sample field chemistry data and laboratory water quality parameter analyses gathered by the WQSP since January 1985 are the foundation for a pre-operational water quality baseline at the WIPP. 32 refs., 66 figs., 96 tabs.

Lyon, M.L. (International Technology Corp., Torrance, CA (USA)) [International Technology Corp., Torrance, CA (USA)

1989-04-01T23:59:59.000Z

166

Social Perceptions of Drinking Water Quality in South Texas  

E-Print Network [OSTI]

quality in the Lower Rio Grande Valley were examined, notably trying to assess the gap in social perceptions between key water managers and the colonia residents. A semi-structured interview methodology was used upon the key water managers in order...

Garcia, Victor

2011-04-28T23:59:59.000Z

167

UMTRA project technical assistance contractor quality assurance implementation plan for surface and ground water, Revision 2  

SciTech Connect (OSTI)

This document contains the Technical Assistance Contractor (TAC) Quality Assurance Implementation Plan (QAIP) for the Uranium Mill Tailings Remedial Action (UMTRA) Project. The QAIP outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QA program is designed to use monitoring, audit, and surveillance activities as management tools to ensure that UMTRA Project activities are carried out in amanner to protect public health and safety, promote the success of the UMTRA Project, and meet or exceed contract requirements.

NONE

1995-11-01T23:59:59.000Z

168

UMTRA project technical assistance contractor quality assurance implementation plan for surface and ground water  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project Technical Assistance Contractor (TAC) Quality Assurance Implementation Plan (QAIP) outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QAIP is subordinate to the latest issue of the UMTRA Project TAC Quality Assurance Program Plan (QAPP). The QAIP addresses technical aspects of the TAC UMTRA Project surface and ground water programs. The QAIP is authorized and approved by the TAC Project Manager and QA manager. The QA program is designed to use monitoring, audit, and surveillance functions as management tools to ensure that all Project organization activities are carried out in a manner that will protect public health and safety, promote the success of the UMTRA Project and meet or exceed contract requirements.

Not Available

1994-09-01T23:59:59.000Z

169

Performance Monitoring of Residential Hot Water Distribution Systems  

SciTech Connect (OSTI)

Current water distribution systems are designed such that users need to run the water for some time to achieve the desired temperature, wasting energy and water in the process. We developed a wireless sensor network for large-scale, long time-series monitoring of residential water end use. Our system consists of flow meters connected to wireless motes transmitting data to a central manager mote, which in turn posts data to our server via the internet. This project also demonstrates a reliable and flexible data collection system that could be configured for various other forms of end use metering in buildings. The purpose of this study was to determine water and energy use and waste in hot water distribution systems in California residences. We installed meters at every end use point and the water heater in 20 homes and collected 1s flow and temperature data over an 8 month period. For a typical shower and dishwasher events, approximately half the energy is wasted. This relatively low efficiency highlights the importance of further examining the energy and water waste in hot water distribution systems.

Liao, Anna; Lanzisera, Steven; Lutz, Jim; Fitting, Christian; Kloss, Margarita; Stiles, Christopher

2014-08-11T23:59:59.000Z

170

Water quality parameter measurement using spectral signatures  

E-Print Network [OSTI]

the photography, and Richard Carter of the Data Processing Center of Texas A4M who digitized the scanner data. As- sistance in preparing and editing the manuscript were provided by my committee members, Dr. W. P. James, and Dr. J. P, German, with special... water shown in figure I-1. I=rom cultures of various phytoplankton, he obtained the signatures shown in figure I-2. Figures I- 1 (P. 10) and I- 2 (p . II) indicate that water has a minimum attenuation and phytoplankton a maximum attenuation at short...

White, Paul Edward

1973-01-01T23:59:59.000Z

171

1994 Environmental monitoring drinking water and nonradiological effluent programs annual report  

SciTech Connect (OSTI)

EG&G Idaho, Inc., initiated monitoring programs for drinking water in 1988 and for nonradiological parameters and pollutants in liquid effluents in 1985. These programs were initiated for the facilities operated by EG&G Idaho for the US Department of Energy at the Idaho National Engineering Laboratory. On October 1, 1994, Lockheed Idaho Technologies Company (LITCO) replaced EG&G Idaho as the prime contractor at the INEL and assumed responsibility for these programs. Section I discusses the general site characteristics, the analytical laboratories, and sampling methodology general to both programs. Section 2, the Drinking Water Program, tracks the bacteriological, chemical, and radiological parameters required by State and Federal regulations. This section describes the drinking water monitoring activities conducted at 17 LITCO-operated production wells and 11 distribution systems. It also contains all of the drinking water parameters detected and the regulatory limits exceeded during calendar year 1994. In addition, groundwater quality is discussed as it relates to contaminants identified at the wellhead for LITCO production wells. Section 3 discusses the nonradiological liquid effluent monitoring results for 27 liquid effluent streams. These streams are presented with emphasis on calendar year 1994 activities. All parameter measurements and concentrations were below the Resource Conservation and Recovery Act toxic characteristics limits.

Andersen, B.D.; Brock, T.A.; Meachum, T.R.

1995-10-01T23:59:59.000Z

172

South Asia Water Resources Workshop: An effort to promote water quality data sharing in South Asia  

SciTech Connect (OSTI)

To promote cooperation in South Asia on environmental research, an international working group comprised of participants from Bangladesh, India, Nepal, Pakistan, Sri Lanka, and the US convened at the Soaltee Hotel in Kathmandu, Nepal, September 12 to 14, 1999. The workshop was sponsored in part by the Cooperative Monitoring Center (CMC) at Sandia National Laboratories in Albuquerque, New Mexico, through funding provided by the Department of Energy (DOE) Office of Nonproliferation and National Security. The CMC promotes collaborations among scientists and researchers in regions throughout the world as a means of achieving common regional security objectives. In the long term, the workshop organizers and participants are interested in the significance of regional information sharing as a means to build confidence and reduce conflict. The intermediate interests of the group focus on activities that might eventually foster regional management of some aspects of water resources utilization. The immediate purpose of the workshop was to begin the implementation phase of a project to collect and share water quality information at a number of river and coastal estuary locations throughout the region. The workshop participants achieved four objectives: (1) gaining a better understanding of the partner organizations involved; (2) garnering the support of existing regional organizations promoting environmental cooperation in South Asia; (3) identifying sites within the region at which data is to be collected; and (4) instituting a data and information collection and sharing process.

RAJEN,GAURAV; BIRINGER,KENT L.; BETSILL,J. DAVID

2000-04-01T23:59:59.000Z

173

Aquatic macroinvertebrates and water quality in Sandia Canyon  

SciTech Connect (OSTI)

In 1990, field studies of water quality and stream macroinvertebrate communities were initiated in Sandia Canyon at Los Alamos National Laboratory. The studies were designed to establish baseline data and to determine the effects of routine discharges of industrial and sanitary waste. Water quality measurements were taken and aquatic macroinvertebrates sampled at three permanent stations within the canyon. Two of the three sample stations are located where the stream regularly receives industrial and sanitary waste effluents. These stations exhibited a low diversity of macroinvertebrates and slightly degraded water quality. The last sample station, located approximately 0.4 km (0.25 mi) downstream from the nearest wastewater outfall, appears to be in a zone of recovery where water quality parameters more closely resemble those found in natural streams in the Los Alamos area. A large increase in macroinvertebrate diversity was also observed at the third station. These results indicate that effluents discharged into Sandia Canyon have a marked effect on water quality and aquatic macroinvertebrate communities.

Bennett, K.

1994-05-01T23:59:59.000Z

174

A Simple Method of Signal Quality Monitoring for WAAS LNAV/VNAV  

E-Print Network [OSTI]

A Simple Method of Signal Quality Monitoring for WAAS LNAV/VNAV Peter Shloss, Raytheon Company R expressed herein. Biographies Mr. Peter Shloss is a Senior Principal Systems Engineer with Raytheon Company

Stanford University

175

Water Use and Water Quality Issues Bryan Swistock Webinar Presentation February 19, 2009  

E-Print Network [OSTI]

whether the chemicals used in hydraulic fracturing may threaten the nation's increasingly precious) that are being investigated for treatment and/or re-use of frac water. Issues that must be overcomeWater Use and Water Quality Issues Bryan Swistock Webinar Presentation February 19, 2009 Questions

Boyer, Elizabeth W.

176

ADEQ Water Quality Forms | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,Information Of TheFixed Logo: ACOREState

177

Alaska Water Quality Standards | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWaterBrasilInformation 5-01 EndStatutes: Title 38 Jump

178

Potential Effects of Organic Carbon Production on Ecosystems and Drinking Water Quality  

E-Print Network [OSTI]

National Primary Drinking Water Regulations, disinfectantsand implications for drinking water quality and the Deltaand control in drinking water. American Chemical Society,

Brown, Larry R.

2003-01-01T23:59:59.000Z

179

texas water resources institute Water management is one of the most significant challenges facing Texas today. Major water quantity and water quality  

E-Print Network [OSTI]

texas water resources institute Water management is one of the most significant challenges facing Texas today. Major water quantity and water quality problems exist, affecting the environment and economy. Texas needs solutions. At the Texas Water Resources Institute, we help solve these pressing water

180

PREV'AIR, a platform for air quality monitoring and fore-, Menut, L.2  

E-Print Network [OSTI]

PREV'AIR, a platform for air quality monitoring and fore- casting Honoré C.1 , Menut, L.2, France 4 ADEME, Paris, France 5 CNRM Meteo-France, Toulouse, France 1 Introduction Since 2003, the PREV'AIR system has been delivering an information about air quality, dedicated to any people or organisation

Menut, Laurent

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Distributed GIS for Monitoring and Modeling Urban Air Quality  

E-Print Network [OSTI]

The progress of technology has made the measurement of air quality and the simulation of complex air pollution models both feasible and cost-effective. However, there is a long way to go in terms of facilitating widespread ...

Yeang, Chen-Hsiang, 1969-

182

Discharge indices for water quality loads Richard M. Vogel  

E-Print Network [OSTI]

: effective discharge, transport, sediment, constituents, rating curve, half-load Citation: Vogel, R. M., J. RDischarge indices for water quality loads Richard M. Vogel Department of Civil and Environmental load is ultimately the quantity of interest, we define a new index, the half-load discharge, which

Vogel, Richard M.

183

Current and Long-Term Effects of Delta Water Quality on Drinking Water Treatment Costs from Disinfection Byproduct Formation  

E-Print Network [OSTI]

existing treatment plant. American Water Woks Association Water Quality Technology.plant, representing an existing treatment configuration, to add alternative disinfection and other technologies.

Chen, Wei-Hsiang; Haunschild, Kristine; Lund, Jay R.; Fleenor, William E.

2010-01-01T23:59:59.000Z

184

Flame quality monitor system for fixed firing rate oil burners  

DOE Patents [OSTI]

A method and apparatus for determining and indicating the flame quality, or efficiency of the air-fuel ratio, in a fixed firing rate heating unit, such as an oil burning furnace, is provided. When the flame brightness falls outside a preset range, the flame quality, or excess air, has changed to the point that the unit should be serviced. The flame quality indicator output is in the form of lights mounted on the front of the unit. A green light indicates that the flame is about in the same condition as when the burner was last serviced. A red light indicates a flame which is either too rich or too lean, and that servicing of the burner is required. At the end of each firing cycle, the flame quality indicator goes into a hold mode which is in effect during the period that the burner remains off. A yellow or amber light indicates that the burner is in the hold mode. In this mode, the flame quality lights indicate the flame condition immediately before the burner turned off. Thus the unit can be viewed when it is off, and the flame condition at the end of the previous firing cycle can be observed.

Butcher, Thomas A. (Pt. Jefferson, NY); Cerniglia, Philip (Moriches, NY)

1992-01-01T23:59:59.000Z

185

Water Quality Sampling Locations Along the Shoreline of the Columbia River, Hanford Site, Washington  

SciTech Connect (OSTI)

As environmental monitoring evolved on the Hanford Site, several different conventions were used to name or describe location information for various sampling sites along the Hanford Reach of the Columbia River. These methods range from handwritten descriptions in field notebooks to the use of modern electronic surveying equipment, such as Global Positioning System receivers. These diverse methods resulted in inconsistent archiving of analytical results in various electronic databases and published reports because of multiple names being used for the same site and inaccurate position data. This document provides listings of sampling sites that are associated with groundwater and river water sampling. The report identifies names and locations for sites associated with sampling: (a) near-river groundwater using aquifer sampling tubes; (b) riverbank springs and springs areas; (c) pore water collected from riverbed sediment; and (d) Columbia River water. Included in the listings are historical names used for a particular site and the best available geographic coordinates for the site, as of 2009. In an effort to create more consistency in the descriptive names used for water quality sampling sites, a naming convention is proposed in this document. The convention assumes that a unique identifier is assigned to each site that is monitored and that this identifier serves electronic database management requirements. The descriptive name is assigned for the convenience of the subsequent data user. As the historical database is used more intensively, this document may be revised as a consequence of discovering potential errors and also because of a need to gain consensus on the proposed naming convention for some water quality monitoring sites.

Peterson, Robert E.; Patton, Gregory W.

2009-12-14T23:59:59.000Z

186

Water Quality Trends in the Entiat River Subbasin: Final 2008 Annual Report.  

SciTech Connect (OSTI)

The ISEMP program monitors the status and trend of water quality elements that may affect restoration project effectiveness in the Entiat subbasin. As part of this effort, the PNW Research Station (PNW) measures, analyzes and interprets temporal trends in natural stream water pH, dissolved oxygen, specific conductivity and temperature. The Entiat River is currently on the Clean Water Act 303(d) list for pH exceedence, and there is insufficient information to determine the spatial and temporal extent or potential causes of this exceedence. In the spring 2008, PNW redeployed data-logging, multiparameter probes at four locations in the Entiat subbasin to measure water quality parameters, focusing on pH. This resumed previous data collection that was interrupted by river ice in early December 2007. Instruments were again removed from the river in early December 2008. This annual report covers the period from December 2007 through December 2008. The highest pH values occurred during the low-flow period from midsummer through the following midspring then dropped sharply during the annual snowmelt runoff period from late spring through early summer. Water temperature began rapidly increasing during the receding limb of the annual snowmelt hydrograph. Highest mean monthly temperatures occurred in July and August, while instantaneous maxima occurred during the period July-September. Dissolved oxygen reached its lowest levels during the period of highest water temperature in July-September. Specific conductivity remained very low at all sites throughout the year.

Woodsmith, Richard; Bookter, Andy [PNW Research Station, USDA Forest Service, Wenatchee, WA

2009-03-30T23:59:59.000Z

187

Preliminary geohydrologic site characterization and proposed water quality well locations for WAG 4, WAG 5, WAG 3, and SWSA 1  

SciTech Connect (OSTI)

The purpose of this report is to assess general site conditions and to recommend water quality well locations at Waste Area Groupings (WAGs) 4, 5 and 3 and Solid Waste Storage Area 1 (SWSA 1) within the Oak Ridge National Laboratory (ORNL) complex. The subject sites are identified on the general site location map. For reference, the relationship of the subject sites to other WAGs are shown. WAGs are regions prescribed by Martin Marietta throughout the ORNL complex that require environmental assessment which will include design and installation of ground water monitoring systems. WAGs contain solid waste management units such as SWSAs, as well as pipelines, spill sites, buildings, ponds and experimental test sites. These solid waste management units are considered to be potential sources of contamination requiring further evaluation. This report recommends locations for water quality wells which will be installed at WAG boundaries in order to gather water quality data.

Baughn, D.C. [MCI/Consulting Engineers, Inc., Knoxville, TN (United States)

1987-03-01T23:59:59.000Z

188

Physico-chemical water quality in Ghana: Prospects for water supply technology implementation   

E-Print Network [OSTI]

S/cm and turbidity from 0 to >542 NTU. Many water samples analysed breached the drinking water quality guidelines. High levels of heavy metals were found and also locations high in sulphate and nitrate. In some regions chemical contaminants such as fluoride occur...

Schäfer, Andrea; Rossiter, H.M.A.; Owusu, P.A.; Richards, B.S.; Awuah, E.

2009-01-01T23:59:59.000Z

189

Relationship of regional water quality to aquifer thermal energy storage  

SciTech Connect (OSTI)

Ground-water quality and associated geologic characteristics may affect the feasibility of aquifer thermal energy storage (ATES) system development in any hydrologic region. This study sought to determine the relationship between ground-water quality parameters and the regional potential for ATES system development. Information was collected from available literature to identify chemical and physical mechanisms that could adversely affect an ATES system. Appropriate beneficiation techniques to counter these potential geochemical and lithologic problems were also identified through the literature search. Regional hydrology summaries and other sources were used in reviewing aquifers of 19 drainage regions in the US to determine generic geochemical characteristics for analysis. Numerical modeling techniques were used to perform geochemical analyses of water quality from 67 selected aquifers. Candidate water resources regions were then identified for exploration and development of ATES. This study identified six principal mechanisms by which ATES reservoir permeability may be impaired: (1) particulate plugging, (2) chemical precipitation, (3) liquid-solid reactions, (4) formation disaggregation, (5) oxidation reactions, and (6) biological activity. Specific proven countermeasures to reduce or eliminate these effects were found. Of the hydrologic regions reviewed, 10 were identified as having the characteristics necessary for ATES development: (1) Mid-Atlantic, (2) South-Atlantic Gulf, (3) Ohio, (4) Upper Mississippi, (5) Lower Mississippi, (6) Souris-Red-Rainy, (7) Missouri Basin, (8) Arkansas-White-Red, (9) Texas-Gulf, and (10) California.

Allen, R.D.

1983-11-01T23:59:59.000Z

190

An alternative approach to achieving water quality-based limits  

SciTech Connect (OSTI)

Since May 1982, members of the Iron and Steel Industry have been required to meet effluent limits based on Best Available Technology (BAT) for a process water discharge to receiving stream. US Steel Clairton Works has been successful in meeting these limits in the last three years; however, the current regulatory thrust is toward more stringent limits based on water quality. In cases of smaller streams such as the receiving stream for Clairton Works` process outfall, these limits can be very rigid. This paper will discuss the alternative approaches investigated to meet the new more stringent limits including the solution chosen.

Hart, C.M.; Graeser, W.C.

1995-12-01T23:59:59.000Z

191

Provide Assistance to Improve Water Quality in Hood County  

E-Print Network [OSTI]

and its impact on the environment: 21 67.7 Understanding of rangeland watersheds: 26 83.9 Understanding of collection and storage of harvested rainwater: 24 77.4 Understanding of filtration and sanitation of harvested rainwater: 27 87.1 Understanding... % Knowledge Gain Understanding of how rainwater addresses water quality and quantity issues: 27.6 Understanding of stormwater and its impact on the environment: 32.1 Understanding of rangeland watersheds: 42.4 Understanding of collection and storage...

Lesikar, Bruce; Mechell, Justin; Clayton, Brent; Gerlich, Ryan

192

Montana 2012 Final Water Quality Integrated Report: Appendix A | Open  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to:46 -Energieprojekte3 Climate Zone Subtype A. PlacesEnergy Information Water Quality

193

Understanding the role of trading in water quality management : based on U.S. experience  

E-Print Network [OSTI]

This research demonstrates an overview of the performance of water quality trading programs currently implemented within the U.S. The role of trading in water quality management is identified through systematical comparisons ...

Pharino, Chanathip

2006-01-01T23:59:59.000Z

194

Radioanalytical Data Quality Objectives and Measurement Quality Objectives during a Federal Radiological Monitoring and Assessment Center Response  

SciTech Connect (OSTI)

During the early and intermediate phases of a nuclear or radiological incident, the Federal Radiological Monitoring and Assessment Center (FRMAC) collects environmental samples that are analyzed by organizations with radioanalytical capability. Resources dedicated to quality assurance (QA) activities must be sufficient to assure that appropriate radioanalytical measurement quality objectives (MQOs) and assessment data quality objectives (DQOs) are met. As the emergency stabilizes, QA activities will evolve commensurate with the need to reach appropriate DQOs. The MQOs represent a compromise between precise analytical determinations and the timeliness necessary for emergency response activities. Minimum detectable concentration (MDC), lower limit of detection, and critical level tests can all serve as measurements reflecting the MQOs. The relationship among protective action guides (PAGs), derived response levels (DRLs), and laboratory detection limits is described. The rationale used to determine the appropriate laboratory detection limit is described.

E. C. Nielsen

2006-01-01T23:59:59.000Z

195

Estimating Water Quality Pollution Impacts Based on Economic Loss Models in Urbanization Process  

E-Print Network [OSTI]

Estimating Water Quality Pollution Impacts Based on Economic Loss Models in Urbanization Process Abstract: The study investigates water quality pollution impacts on urbanization by analyzing temporal, more populations were moved from rural area into urban area, and more costs were input in water quality

Yu, Qian

196

MAQS: A Personalized Mobile Sensing System for Indoor Air Quality Monitoring  

E-Print Network [OSTI]

quality (IAQ) influences human health, safety, productivity, and comfort. This paper describes MAQS, a personalized mobile sensing system for IAQ monitoring. In contrast with existing stationary or out- door air personalized IAQ information. To improve accuracy and energy efficiency, MAQS incorporates three novel

Dick, Robert

197

Wastewater Regulations for National Pollutant Discharge Elimination System (NPDES) Permits, Underground Injection Control (UIC) Permits, State Permits, Water Quality Based Effluent Limitations and Water Quality Certification (Mississippi)  

Broader source: Energy.gov [DOE]

The Wastewater Regulations for National Pollutant Discharge Elimination System (NPDES) Permits, Underground Injection Control (UIC) Permits, State Permits, Water Quality Based Effluent Limitations...

198

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Site  

SciTech Connect (OSTI)

This document of Data Quality Objectives (DQOs) was prepared based on the U.S. Environmental Protection Agency (EPA) Guidance on Systematic Planning Using the Data Quality Objectives Process, EPA, QA/G4, 2/2006 (EPA 2006) as well as several other published DQOs. Pacific Northwest National Laboratory (PNNL) is in the process of developing a radiological air monitoring program for the PNNL Site that is distinct from that of the nearby Hanford Site. Radiological emissions at the PNNL Site result from Physical Sciences Facility (PSF) major emissions units. A team was established to determine how the PNNL Site would meet federal regulations and address guidelines developed to monitor and estimate offsite air emissions of radioactive materials. The result is a program that monitors the impact to the public from the PNNL Site.

Barnett, J. M.; Meier, Kirsten M.; Snyder, Sandra F.; Fritz, Brad G.; Poston, Ted M.; Rhoads, Kathleen

2010-05-25T23:59:59.000Z

199

2014 Virginia Polytechnic Institute and State University BSE-158NP Household Water Quality in Loudoun County, Virginia  

E-Print Network [OSTI]

2014 Virginia Polytechnic Institute and State University BSE-158NP Household Water Quality in Loudoun County, Virginia OCTOBER 2013 VIRGINIA HOUSEHOLD WATER QUALITY PROGRAM Erin Ling, Water Quality Extension Associate, and Brian Benham, Extension Specialist and Professor

Liskiewicz, Maciej

200

2014 Virginia Polytechnic Institute and State University BSE-151NP Household Water Quality in Albemarle County, Virginia  

E-Print Network [OSTI]

2014 Virginia Polytechnic Institute and State University BSE-151NP Household Water Quality in Albemarle County, Virginia APRIL 2013 VIRGINIA HOUSEHOLD WATER QUALITY PROGRAM Erin Ling, Water Quality Extension Associate, and Brian Benham, Extension Specialist and Professor

Liskiewicz, Maciej

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

2014 Virginia Polytechnic Institute and State University BSE-162NP Household Water Quality in Pittsylvania County, Virginia  

E-Print Network [OSTI]

2014 Virginia Polytechnic Institute and State University BSE-162NP Household Water Quality in Pittsylvania County, Virginia OCTOBER 2013 VIRGINIA HOUSEHOLD WATER QUALITY PROGRAM Erin Ling, Water Quality Extension Associate, and Brian Benham, Extension Specialist and Professor

Liskiewicz, Maciej

202

Concept Paper for Real-Time Temperature and Water Quality Management for San Joaquin River Riparian Habitat Restoration  

E-Print Network [OSTI]

Report. Real-time Water Quality Management for SJR RiparianReal-time Water Quality Management for SJR Riparian HabitatPaper Real-time Water Quality Management for SJR Riparian

Quinn, Nigel W.T.

2004-01-01T23:59:59.000Z

203

Annual Monitoring Results A REPORT OF THE REGIONAL MONITORING PROGRAM  

E-Print Network [OSTI]

Grainsize 33 Total Organic Carbon (TOC) and Total Nitrogen (TN)33 Trace Metals34 Trace Organics34 Quality Assurance / Quality Control (QA/QC) 37 QA/QC of Percent Solids37 QA/QC of Grain Size 37 QA/QC of TotalAnnual Monitoring Results 2012 A REPORT OF THE REGIONAL MONITORING PROGRAM FOR WATER QUALITY

204

Coupling upland watershed and downstream waterbody hydrodynamic and water quality models  

E-Print Network [OSTI]

. Such models lack the capacity to simulate the hydrodynamics and water quality processes of larger waterCoupling upland watershed and downstream waterbody hydrodynamic and water quality models (SWAT and CE-QUAL-W2) for better water resources management in complex river basins B. Debele & R. Srinivasan

205

Water Quality 101 Dr. Mike Mallin and Matthew McIver  

E-Print Network [OSTI]

+ organic nitrogen Silicate Heavy metals ­ water column aluminum arsenic cadmium chromium copper1 Water Quality 101 Dr. Mike Mallin and Matthew McIver Aquatic Ecology Laboratory UNCW-Center for Marine Science Common Water Quality Sampling Parameters and Analytical Procedures Water temperature

Mallin, Michael

206

Risk perception, drinking water source and quality in a low-income Latino community  

E-Print Network [OSTI]

Risk perception, drinking water source and quality in a low-income Latino community along the U regarding the quality of municipal drinking water supplies The Arizona Republic. 2007. Thirsty Arizona. Vol of bottled and tap water used by residents in Nogales, AZ according to the EPA primary drinking water

Fay, Noah

207

Water Quality Issues facing Indigenous Peoples in North America and Siberia  

E-Print Network [OSTI]

and reverence for water resources in both communities, and that both communities have defined protocols for their interactions with water resources. Each community is facing threats to their water quality from different sources of pollution, and may benefit from...

Mehl, Heidi Elizabeth

2009-04-29T23:59:59.000Z

208

Method, system and apparatus for monitoring and adjusting the quality of indoor air  

DOE Patents [OSTI]

A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.

Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.

2004-03-23T23:59:59.000Z

209

Resource Conservation and Recovery Act ground-water monitoring projects for Hanford facilities: Progress report for the period October 1 to December 31, 1989  

SciTech Connect (OSTI)

This is Volume 1 of a two-volume document that describes the progress of 15 Hanford Site ground-water monitoring projects for the period October 1 to December 31, 1989. This volume discusses the projects. The work described in this document is conducted by the Pacific Northwest Laboratory under the management of Westinghouse Hanford Company for the US Department of Energy. Concentrations of ground-water constituents are compared to federal drinking water standards throughout this document for reference purposes. All drinking water supplied from the samples aquifer meets regulatory standards for drinking water quality. 51 refs., 35 figs., 86 tabs.

Smith, R.M.; Bates, D.J.; Lundgren, R.E. (eds.)

1990-03-01T23:59:59.000Z

210

Water Pollution (Illinois)  

Broader source: Energy.gov [DOE]

This article states regulations for water quality standards, effluent standards, monitoring and reporting methods, sewer discharge criteria and information about permits. It is the purpose of...

211

Biofuels and water quality: challenges and opportunities for simulation modeling  

SciTech Connect (OSTI)

Quantification of the various impacts of biofuel feedstock production on hydrology and water quality is complex. Mathematical models can be used to efficiently evaluate various what if scenarios related to biofeedstock production and their impacts on hydrology and water quality at various spatial and temporal scales. Currently available models, although having the potential to serve such purposes, have many limitations. In this paper, we review the strengths and weaknesses of such models in light of short- and long term biofeedstock production scenarios. The representation of processes in the currently available models and how these processes need to be modified to fully evaluate various complex biofeedstock production scenarios are discussed. Similarly, issues related to availability of data that are needed to parameterize and evaluate these models are presented. We have presented a vision for the development of decision support tools and ecosystem services that can be used to make watershed management decisions to minimize any potentially adverse environmental impacts while meeting biofeedstock demands. We also discuss a case study of biofeedstock impact simulation in relation to watershed management policy implications for various state and federal agencies in the USA.

Engel, Bernard A. [Purdue University; Chaubey, Indrajeet [Purdue University; Thomas, Mark [Purdue University; Saraswat, Dharmendra [University of Arkansas; Murphy, Patrick [Purdue University; Bhaduri, Budhendra L [ORNL

2010-01-01T23:59:59.000Z

212

DATA QUALITY OBJECTIVES SUMMARY REPORT FOR WASTE DISPOSITION OF FY2004 ISRM INJECTION & MONITORING WELLS  

SciTech Connect (OSTI)

The purpose of this data quality objective (DQO) summary report is to develop a sampling plan for waste disposition of soil cuttings and other drilling-related wastes that will result from the drilling of 21 injection wells and one groundwater monitoring well west of the 184-D Powerhouse Ash Pit in the 100-D Area of the Hanford Site. The 21 In Situ Redox Manipulation (ISRM) wells will inject treatment solutions to assist in intercepting and preventing the discharge of a hexavalent chromium plume to the Columbia River. The monitoring well will help establish groundwater chemistry downgradient of the ISRM zone. The proposed well locations are shown.

THOMAS, G.

2004-03-03T23:59:59.000Z

213

Dedicated to Sharing Information About Water Management and the Florida LAKEWATCH Program Volume 58 (2012) Volunteer Ground-Water Monitoring Coming to  

E-Print Network [OSTI]

Water Management Districts (WMDs) or the Florida Department of Environmental1 Dedicated to Sharing Information About Water Management and the Florida LAKEWATCH Program being monitored for water levels by the state's water management districts

Florida, University of

214

APPROACHES TO EVALUATE WATER QUALITY MODEL PARAMETER UNCERTAINTY FOR ADAPTIVE TMDL IMPLEMENTATION1  

E-Print Network [OSTI]

is particularly handy for that task. (KEY TERMS: total maximum daily load; water quality model; ecological quality management and decisions such as total maximum daily load (TMDL) determinations (NRC 2001). ModelsAPPROACHES TO EVALUATE WATER QUALITY MODEL PARAMETER UNCERTAINTY FOR ADAPTIVE TMDL IMPLEMENTATION1

215

Water Quality 5 2004 SITE ENVIRONMENTAL REPORT5-1  

E-Print Network [OSTI]

. Monitoring, pollution prevention, and careful operation of treatment facilities help ensure that wastewater Monitor for Radioactivity, pH, Conductivity Blower Building Abandoned Sand Filter Beds Emergency Holding

216

DECEMBER 2008 WATER QUALITY AND LAND USE: IMPLICATIONS FOR REGULATION AND  

E-Print Network [OSTI]

DECEMBER 2008 WATER QUALITY AND LAND USE: IMPLICATIONS FOR REGULATION AND URBAN PLANNING WRRI Technical Completion Report No. 346 Gwendolyn A. Aldrich Janie Chermak Jennifer A. Thacher NEW MEXICO WATER-0001 Telephone (505) 646-4337 FAX (505) 646-6418 email: nmwrri@wrri.nmsu.edu #12;WATER QUALITY AND LAND USE

Johnson, Eric E.

217

Optimizing turbine withdrawal from a tropical reservoir for improved water quality in downstream wetlands  

E-Print Network [OSTI]

Optimizing turbine withdrawal from a tropical reservoir for improved water quality in downstream using Itezhi-Tezhi Reservoir (Zambia) as a model system aims at defining optimized turbine withdrawal. The water depth of turbine withdrawals was varied in a set of simulations to optimize outflow water quality

Wehrli, Bernhard

218

Improvement of Drinking Water Quality in Developing Countries: Microbial and Geogenic Contamination  

E-Print Network [OSTI]

Improvement of Drinking Water Quality in Developing Countries: Microbial and Geogenic Contamination for chemical and micro- biological treatment of drinking water at the household scale. The course will cover in developing and emerging coun- tries, who wish to learn more about household drinking water quality

Wehrli, Bernhard

219

NEAR FIELD RECEIVING WATER MONITORING OF TRACE METALS IN CLAMS (MACOMA BALTHICA) AND SEDIMENTS  

E-Print Network [OSTI]

THE PALO ALTO WATER QUALITY CONTROL PLANT IN SOUTH SAN FRANCISCO BAY, CALIFORNIA: 1999 NEAR THE PALO ALTO WATER QUALITY CONTROL PLANT IN SOUTH SAN FRANCISCO BAY, CALIFORNIA: 1999-2001 Carlos................................................................................................................................. 13 5. Graph showing near-total and acid-extractable copper concentrations in sediments from 1994

220

Routine Radiological Environmental Monitoring Plan, Volume 2 Appendices  

SciTech Connect (OSTI)

Supporting material for the plan includes: QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR NTS AIR; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR WATER ON AND OFF THE NEVADA TEST SITE; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR NTS BIOTA; QUALITY ASSURANCE, ANALYSIS, AND SAMPLING PLAN FOR DIRECT RADIATION MONITORING; DATA QUALITY OBJECTIVES PROCESS; VADOSE ZONE MONITORING PLAN CHECKLIST.

Bechtel Nevada

1998-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

PURPOSE: This product provides simulation capabilities to allow water resource managers to meet operational and water quality objectives in a basin wide approach under the System-Wide  

E-Print Network [OSTI]

Manage- ment System (CWMS). ERDC TN-SWWRP-11-2 February 2011 Meeting Water Quality and Water Control operational and water quality objectives in a basin wide approach under the System-Wide Water Resources the impact of water quality in reservoir operations system decision-making. As a result, integration

US Army Corps of Engineers

222

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL Site  

SciTech Connect (OSTI)

Pacific Northwest National Laboratory (PNNL) is in the process of developing a radiological air monitoring program for the PNNL Site that is distinct from that of the nearby Hanford Site. The original DQO (PNNL-19427) considered radiological emissions at the PNNL Site from Physical Sciences Facility (PSF) major emissions units. This first revision considers PNNL Site changes subsequent to the implementation of the original DQO. A team was established to determine how the PNNL Site changes would continue to meet federal regulations and address guidelines developed to monitor air emissions and estimate offsite impacts of radioactive material operations. The result is an updated program to monitor the impact to the public from the PNNL Site. The team used the emission unit operation parameters and local meteorological data as well as information from the PSF Potential-to-Emit documentation and Notices of Construction submitted to the Washington State Department of Health (WDOH). The locations where environmental monitoring stations would most successfully characterize the maximum offsite impacts of PNNL Site emissions from the three PSF buildings with major emission units were determined from these data. Three monitoring station locations were determined during the original revision of this document. This first revision considers expanded Department of Energy operations south of the PNNL Site and relocation of the two offsite, northern monitoring stations to sites near the PNNL Site fenceline. Inclusion of the southern facilities resulted in the proposal for a fourth monitoring station in the southern region. The southern expansion added two minor emission unit facilities and one diffuse emission unit facility. Relocation of the two northern stations was possible due to the use of solar power, rather than the previous limitation of the need for access to AC power, at these more remote locations. Addendum A contains all the changes brought about by the revision 1 considerations. This DQO report also updates the discussion of the Environmental Monitoring Plan for the PNNL Site air samples and how existing Hanford Site monitoring program results could be used. This document of Data Quality Objectives (DQOs) was prepared based on the U.S. Environmental Protection Agency (EPA) Guidance on Systematic Planning Using the Data Quality Objectives Process, EPA, QA/G4, 2/2006 (EPA 2006) as well as several other published DQOs.

Barnett, J. M.; Meier, Kirsten M.; Snyder, Sandra F.; Fritz, Brad G.; Poston, Theodore M.; Antonio, Ernest J.

2012-11-12T23:59:59.000Z

223

Drought and Precipitation Monitoring for Enhanced Integrated Water Resources Management in the Caribbean  

E-Print Network [OSTI]

Drought and Precipitation Monitoring for Enhanced Integrated Water Resources Management for water resource management in Jamaica, Grenada and Guyana. A key element to ensuring the success for Water Resources Management, McGill University, Macdonald Campus, 21111 Lakeshore Rd., Ste. Anne de

Barthelat, Francois

224

Water quality investigation of Kingston Fossil Plant dry ash stacking  

SciTech Connect (OSTI)

Changing to a dry ash disposal systems at Kingston Fossil Plant (KFP) raises several water quality issues. The first is that removing the fly ash from the ash pond could alter the characteristics of the ash pond discharge to the river. The second concerns proper disposal of the runoff and possibly leachate from the dry ash stack. The third is that dry ash stacking might change the potential for groundwater contamination at the KFP. This report addresses each of these issues. The effects on the ash pond and its discharge are described first. The report is intended to provide reference material to TVA staff in preparation of environmental review documents for new ash disposal areas at Kingston. Although the investigation was directed toward analysis of dry stacking, considerations for other disposal options are also discussed. This report was reviewed in draft form under the title Assessment of Kingston Fossil Plant Dry Ash Stacking on the Ash Pond and Groundwater Quality.'' 11 refs., 3 figs., 18 tabs.

Bohac, C.E.

1990-04-01T23:59:59.000Z

225

assessing water-quality conditions: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

requirements for the degree of MASTER OF SCIENCE... Richards, Chad Edward 2005-02-17 26 TECHNOLOGY Assessment of Physico-chemical Water Quality Parameters of Surajkund Pondin...

226

Morphology, hydrology, and water quality of two vernal pools in Madera County, California  

E-Print Network [OSTI]

regime on vernal pool hydrology. Freshwater Biology 50:and L. Stromberg. (1998). Hydrology of vernal pools on non-Morphology, hydrology, and water quality of two vernal pools

Renz, Wendy; Higgins, Tanya

2006-01-01T23:59:59.000Z

227

E-Print Network 3.0 - awwa water quality Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Relevant Coursework: Principles of Environmental Chemistry Water and Wastewater Treatment... EPA quality control mandates Worked with Operations department to help achieve...

228

Application of Specialized Optimization Techniques in Water Quantity and Quality Management with Respect to Planning for the Trinity River Basi  

E-Print Network [OSTI]

for the disposal of wastes. Thus, there is a clear interaction between quantity and quality of water. However, largely due to the agency structure in state and federal government, water quality management and water development activities are usually separated...

Meier Jr., W. L.; Shih, C. S.

229

Biosensors & Bioelectronics 16 (2001) 811818 Monitoring of phosphorus bioavailability in water by an  

E-Print Network [OSTI]

of cyanobacteria, known as `algal blooms', has become a major concern for water monitoring. It has been observed from cyanobacterial secretions (Klapper, 1992). Some strains of cyanobacterial genera found in blooms

Gillor, Osnat

230

Vendors of Supplies and Equipment Used in ReceivingWater Monitoring  

E-Print Network [OSTI]

APPENDIX J Vendors of Supplies and Equipment Used in Receiving­Water Monitoring CONTENTS General)................................................................874 GENERAL FIELD AND LABORATORY EQUIPMENT The following vendors and manufacturers supply a large

Pitt, Robert E.

231

Factors Influencing Water Heating Energy Use and Peak Demand in a Large Scale Residential Monitoring Study  

E-Print Network [OSTI]

, as well as obtain improved appliance energy consumption indexes and load profiles. A portion of the monitoring measures water heater energy use and demand in each home on a 15-minute basis....

Bouchelle, M. P.; Parker, D. S.; Anello, M. T.

2000-01-01T23:59:59.000Z

232

Water Quality 5 2005 Site environmental report5-  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities-N Real Time Monitor for Radioactivity, pH, Conductivity Blower Building Abandoned Sand Filter Beds

233

Water Quality 5 2008 Site environmental report5-  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities Sampling Station HM-N Real Time Monitor for Radioactivity, pH, Conductivity Blower Building Abandoned Sand

234

Water quality prediction for recreational use of Kranji Reservoir, Singapore  

E-Print Network [OSTI]

Singapore has been making efforts in relieving its water shortage problems and has been making great progress through its holistic water management. Via the Active, Beautiful, Clean Waters (ABC Waters) Programme, Singapore's ...

Zhang, Yangyue

2011-01-01T23:59:59.000Z

235

Ground-water monitoring compliance plan for the Hanford Site Solid Waste Landfill  

SciTech Connect (OSTI)

Washington state regulations required that solid waste landfill facilities have ground-water monitoring programs in place by May 27, 1987. This document describes the well locations, installation, characterization studies and sampling and analysis plan to be followed in implementing the ground-water monitoring program at the Hanford Site Solid Waste Landfill (SWL). It is based on Washington Administrative Code WAC 173-304-490. 11 refs., 19 figs., 4 tabs.

Fruland, R.M.

1986-10-01T23:59:59.000Z

236

Feasibility of Using Measurements of Internal Components ofTankless Water Heaters for Field Monitoring of Energy and Water Use  

SciTech Connect (OSTI)

The objective of this study was to determine if it was feasible to collect information regarding energy use and hot water delivery from tankless gas water heaters using the sensors and controls built into the water heaters. This could then be used to determine the water heater efficiency ? the ratio of energy out (hot water delivered) to energy in (energy in the gas) in actual residential installations. The goal was to be as unobtrusive as possible, and to avoid invalidating warranties or exposing researchers to liability issues. If feasible this approach would reduce the costs of instrumentation.This paper describes the limited field and laboratory investigations to determine if using the sensors and controls built into tankless water heaters is feasible for field monitoring.It was more complicated to use the existing gas flow, water and temperature sensors than was anticipated. To get the signals from the existing sensors and controls is difficult and may involve making changes that would invalidate manufacturer warrantees. The procedures and methods for using signals from the existing gas valves, water flow meters and temperature sensors will vary by model. To be able to monitor different models and brands would require detailed information about each model and brand.Based on these findings, we believe that for field monitoring projects it would be easier, quicker and safer to connect external meters to measure the same parameters rather than using the sensors and controls built into tankless water heaters.

Lutz, Jim; Biermayer, Peter

2008-04-17T23:59:59.000Z

237

Monitoring and data quality assessment of the ATLAS liquid argon calorimeter  

E-Print Network [OSTI]

The liquid argon calorimeter is a key component of the ATLAS detector installed at the CERN Large Hadron Collider. The primary purpose of this calorimeter is the measurement of electrons and photons. It also provides a crucial input for measuring jets and missing transverse momentum. An advanced data monitoring procedure was designed to quickly identify issues that would affect detector performance and ensure that only the best quality data are used for physics analysis. This article presents the validation procedure developed during the 2011 and 2012 LHC data taking periods, in which more than 98% of the proton proton luminosity recorded by ATLAS at a centre-of-mass energy of 7 and 8 TeV had calorimeter data quality suitable for physics analysis.

ATLAS Collaboration

2014-07-24T23:59:59.000Z

238

Blazing and grazing: influences of fire and bison on tallgrass prairie stream water quality  

E-Print Network [OSTI]

Blazing and grazing: influences of fire and bison on tallgrass prairie stream water quality Danelle for maintaining and managing tallgrass prairie, but we know little about their influences on water-quality dynamics in streams. We analyzed 2 y of data on total suspended solids (TSS), total N (TN), and total P (TP

Dodds, Walter

239

Risk-based modelling of surface water quality: a case study of the Charles River, Massachusetts  

E-Print Network [OSTI]

: Water quality; Risk; Monte Carlo; Sensitivity analysis; Eutrophication 1. Introduction 1.1. Motivation recognised in the development of some decision-support tools, for example, QUAL2E- UNCAS (Brown and BarnwellRisk-based modelling of surface water quality: a case study of the Charles River, Massachusetts

Wagener, Thorsten

240

Groundwater quality monitoring well installation for Waste Area Grouping at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program  

SciTech Connect (OSTI)

This report documents the drilling and installation of 18 groundwater quality monitoring (GQM) wells on the perimeter of Waste Area Grouping (WAG) 11. WAG 11 (White Wing Scrap Yard) is located on the west end of East Fork Ridge between White Wing Road and the Oak Ridge Turnpike. The scrap yard is approximately 25 acres in size. The wells at WAG 11 were drilled and developed between January 1990 and October 1990. These wells were installed to characterize and assess the WAG in accordance with applicable Department of Energy, state, and Environmental Protection Agency regulatory requirements. The wells at WAG 11 were drilled with auger or air rotary rigs. Depending on the hydrogeologic conditions present at each proposed well location, one of four basic installation methods was utilized. Detailed procedures for well construction were specified by the Engineering Division to ensure that the wells would provide water samples representative of the aquifer. To ensure conformance with the specifications, Energy Systems Construction Engineering and ERCE provided continuous oversight of field activities. The purpose of the well installation program was to install GQM wells for groundwater characterization at WAG 11. Data packages produced during installation activities by the ERCE hydrogeologists are an important product of the program. These packages document the well drilling, installation, and development activities and provide valuable data for well sampling and WAG characterization. The forms contained in the packages include predrilling and postdrilling checklists, drilling and construction logs, development and hydraulic conductivity records, and quality control-related documents.

Mortimore, J.A.; Lee, T.A.

1994-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Environmental sensor networks and continuous data quality assurance to manage salinity within a highly regulated river basin  

E-Print Network [OSTI]

and Drainage System for Drainage Water Quality Management,quality management using a novel software tool, Aquarius. Commercial turn-key monitoring systems

Quinn, N.W.T.

2010-01-01T23:59:59.000Z

242

Analysing chromatographic data using data mining to monitor petroleum content in water  

E-Print Network [OSTI]

Analysing chromatographic data using data mining to monitor petroleum content in water Geoffrey the concentrations of petroleum compounds in water samples. Experiments demonstrate that the framework can be used, New Zealand. Abstract Chromatography is an important analytical technique that has wide- spread use

Frank, Eibe

243

Onsite Wastewater Treatment Systems: Graywater Use and Water Quality  

E-Print Network [OSTI]

their homes in their landscapes. This reuse of graywater can reduce the amount of wastewater entering sewers or treatment systems, reduce the amount of fresh water used on landscapes and help preserve limited fresh water supplies. Onsite wastewater...-washing machines ? The code excludes water that has washed materials soiled with human waste, such as diapers, and water that has been in contact with toilet waste. This water, known as blackwater, includes flush water from toilets and urinals and wastewater...

Lesikar, Bruce J.; Mechell, Justin; Alexander, Rachel

2008-08-28T23:59:59.000Z

244

Water Quality 5 2006 Site environmental report5-  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities Building Abandoned Sand Filter Beds Emergency Holding Ponds (lined) Pump Station Sludge Drying Apparatus

245

2011 Site environmental report5-1 Water Quality  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities Abandoned Sand Filter Beds Emergency Holding Ponds (lined) Pump Station Sludge Drying Apparatus Sludge Pumps

246

Interferometric tomography of fuel cells for monitoring membrane water content  

E-Print Network [OSTI]

We have developed a system that uses two 1D interferometric phase projections for reconstruction of 2D water content changes over time in situ in a proton exchange membrane (PEM) fuel cell system. By modifying the filtered ...

Waller, Laura

247

CONSTRUCTED WETLAND TREATMENT SYSTEMS FOR WATER QUALITY IMPROVEMENT  

SciTech Connect (OSTI)

The Savannah River National Laboratory implemented a constructed wetland treatment system (CWTS) in 2000 to treat industrial discharge and stormwater from the Laboratory area. The industrial discharge volume is 3,030 m{sup 3} per day with elevated toxicity and metals (copper, zinc and mercury). The CWTS was identified as the best treatment option based on performance, capital and continuing cost, and schedule. A key factor for this natural system approach was the long-term binding capacity of heavy metals (especially copper, lead, and zinc) in the organic matter and sediments. The design required that the wetland treat the average daily discharge volume and be able to handle 83,280 m{sup 3} of stormwater runoff in a 24 hour period. The design allowed all water flow within the system to be driven entirely by gravity. The CWTS for A-01 outfall is composed of eight one-acre wetland cells connected in pairs and planted with giant bulrush to provide continuous organic matter input to the system. The retention basin was designed to hold stormwater flow and to allow controlled discharge to the wetland. The system became operational in October of 2000 and is the first wetland treatment system permitted by South Carolina DHEC for removal of metals. Because of the exceptional performance of the A-01 CWTS, the same strategy was used to improve water quality of the H-02 outfall that receives discharge and stormwater from the Tritium Area of SRS. The primary contaminants in this outfall were also copper and zinc. The design for this second system required that the wetland treat the average discharge volume of 415 m{sup 3} per day, and be able to handle 9,690 m{sup 3} of stormwater runoff in a 24 hour period. This allowed the building of a system much smaller than the A-01 CWTS. The system became operational in July 2007. Metal removal has been excellent since water flow through the treatment systems began, and performance improved with the maturation of the vegetation during the first season of growth of each system. Sediment samples after the first and third years of operation indicated that copper was being bound in the sediments very rapidly after entering the treatment system. The design of the system encourages low redox and sulfide production in the sediments. The objective is to stabilize metals, including mercury, as sulfide compounds in the sediments. Costs for maintenance and operation of the systems are minimal, consisting primarily of ensuring that the pipes are not clogged and that water is flowing through the system. The treatment cost per thousand gallons is many times less than conventional wastewater treatment facilities. Life expectancy and function of the biological system is based on the life of the engineering aspects and not the wetland ecology.

Nelson, E.

2010-07-19T23:59:59.000Z

248

The impact of climate change on vadose zone pore waters and its implication for long-term monitoring  

SciTech Connect (OSTI)

Protecting groundwater is of growing interest as pressure on these resources grows. Recharge of groundwater takes place through the vadose zone, where complex interactions between thermal-hydrological-geochemical processes affect water quality. Monitoring processes in the vadose zone is an important means of evaluating the long-term health of aquifer systems, and has become an integral part of many subsurface engineering efforts. Monitoring such systems, however, may be affected by changes in climate that slowly propagate through vadose zone systems. We describe in this paper the use of NUFT-C, a reactive transport simulator designed to run on a high performance, massively parallel computer, to compare quantitatively the evolution of a deep vadose zone with changes expected from an engineered high-level nuclear waste repository. The results suggest that the impacts from waste emplacement are, in some instances, similar to those that would be observed as a result of climate change, whereas others are distinguishable from evolution of the natural system. Such simulations facilitate design of long-term monitoring programs that take account of these complex effects. The results emphasize the importance of developing long-term baseline measurements and control sites, in order to enhance confidence in interpretations of complexly evolving data sets that will be obtained from multi-decade monitoring efforts.

Glassley, William E.; Nitao, John J.; Grant, Charles W.; Johnson, James W.; Steefel, Carl I.; Kercher, James R.

2003-03-01T23:59:59.000Z

249

Water Use and Quality Assessment | Argonne National Laboratory  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

energy security and climate change, and not on the possible effects increased biofuel production may have on the quality and quantity of local and regional freshwater...

250

Water-Quality Trading: Can We Get the Price of Pollution Right?1  

E-Print Network [OSTI]

Water-Quality Trading: Can We Get the Price of Pollution Right?1 Yoshifumi Konishi Faculty for pollution can work for air. Should they not work for water pollution too? The U.S. Environmental Protection known (Mauzerall et al., 2005). Spatial dependence is likely even more prominent for water pollution

Weiblen, George D

251

In 2006 and 2007, the Division of Water Qual-ity, North Carolina Department of Environment  

E-Print Network [OSTI]

Roofs, and Water Harvesting (AG-588-6). As the use of permeable pavement increases in North Carolina In 2006 and 2007, the Division of Water Qual- ity, North Carolina Department of Environment: permeable pave- ment runoff reduction, clogging, long-term hydrology, and water quality. In this update

Hunt, William F.

252

2010 SITE ENVIRONMENTAL REPORT5-1 Water Quality  

E-Print Network [OSTI]

prevention, and vigilant operation of treatment facilities ensure that these discharges comply with all-N Real Time Monitor for Radioactivity, pH, Conductivity Blower Building Abandoned Sand Filter Beds

253

2013 SITE ENVIRONMENTAL REPORT5-1 Water Quality  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities for Radioactivity, pH, Conductivity Blower Building Abandoned Sand Filter Beds Emergency Holding Ponds (lined) Pump

254

2012 SITE ENVIRONMENTAL REPORT5-1 Water Quality  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities for Radioactivity, pH, Conductivity Blower Building Abandoned Sand Filter Beds Emergency Holding Ponds (lined) Pump

255

Water Quality 5 2007 Site environmental report5-  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and vigilant operation of treatment facilities for Radioactivity, pH, Conductivity Blower Building Abandoned Sand Filter Beds Emergency Holding Ponds (lined) Pump

256

Establishment of a Hub for the Light Water Reactor Sustainability Online Monitoring Community  

SciTech Connect (OSTI)

Implementation of online monitoring and prognostics in existing U.S. nuclear power plants will involve coordinating the efforts of national laboratories, utilities, universities, and private companies. Internet-based collaborative work environments provide necessary communication tools to facilitate interaction between geographically diverse participants. Available technologies were considered, and a collaborative workspace was established at INL as a hub for the light water reactor sustainability online monitoring community.

Nancy J. Lybeck; Magdy S. Tawfik; Binh T. Pham

2011-08-01T23:59:59.000Z

257

Seymour Aquifer Water Quality Improvement Project Final Report  

E-Print Network [OSTI]

, Wilbarger, and Fisher counties exceeded the federal safe drinking water standard (10 mg/L NO3-N). This high concentration is a concern because although 90% of the water pumped from the aquifer is used for irrigation, it is also used as a municipal water...

Sij, J.; Morgan, C.; Belew, M.; Jones, D.; Wagner, K.

258

40 CFR 265 interim-status ground-water monitoring plan for the 2101-M pond  

SciTech Connect (OSTI)

This report outlines a ground-water monitoring plan for the 2101-M pond, located in the southwestern part of the 200-East Area on the Hanford Site in south-central Washington State. It has been determined that hazardous materials may have been discharged to the pond. Installation of an interim-status ground-water monitoring system is required under the Resource Conservation and Recovery Act to determine if hazardous chemicals are moving out of the pond. This plan describes the location of new wells for the monitoring system, how the wells are to be completed, the data to be collected, and how those data can be used to determine the source and extent of any ground-water contamination from the 2101-M pond. Four new wells are planned, one upgradient and three downgradient. 35 refs., 12 figs., 9 tabs.

Chamness, M.A.; Luttrell, S.P.; Dudziak, S.

1989-03-01T23:59:59.000Z

259

Use of environmental sensors and sensor networks to develop water and salinity budgets for seasonal wetland real-time water quality management  

SciTech Connect (OSTI)

Successful management of river salt loads in complex and highly regulated river basins such as the San Joaquin of California presents significant challenges to Information Technology. Models are used as means of simulating major hydrologic processes in the basin which affect water quality and can be useful as tools for organizing basin information in a structured and readily accessible manner. Models can also be used to extrapolate the results of system monitoring since it is impossible to collect data for every point and non-point source of a pollutant in the Basin. Fundamental to every model is the concept of mass balance. This paper describes the use of state-of-the-art sensor technologies deployed in concert to obtain the first water and salinity budgets for a 60,000 hectare tract of seasonally managed wetlands in the San Joaquin Basin of California.

Quinn, N.W.T.; Ortega, R.; Rahilly, P.J.A,; Royer, C.W.

2009-10-01T23:59:59.000Z

260

Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT  

SciTech Connect (OSTI)

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time 3D tumor monitoring system for cancer radiotherapy. KIM uses the commonly available gantry-mounted x-ray imager as input, making this method potentially more widely available than dedicated real-time 3D tumor monitoring systems. KIM is being piloted in a clinical trial for prostate cancer patients treated with VMAT (NCT01742403). The purpose of this work was to develop clinical process and quality assurance (QA) practices for the clinical implementation of KIM. Methods: Informed by and adapting existing guideline documents from other real-time monitoring systems, KIM-specific QA practices were developed. The following five KIM-specific QA tests were included: (1) static localization accuracy, (2) dynamic localization accuracy, (3) treatment interruption accuracy, (4) latency measurement, and (5) clinical conditions accuracy. Tests (1)–(4) were performed using KIM to measure static and representative patient-derived prostate motion trajectories using a 3D programmable motion stage supporting an anthropomorphic phantom with implanted gold markers to represent the clinical treatment scenario. The threshold for system tolerable latency is <1 s. The tolerances for all other tests are that both the mean and standard deviation of the difference between the programmed trajectory and the measured data are <1 mm. The (5) clinical conditions accuracy test compared the KIM measured positions with those measured by kV/megavoltage (MV) triangulation from five treatment fractions acquired in a previous pilot study. Results: For the (1) static localization, (2) dynamic localization, and (3) treatment interruption accuracy tests, the mean and standard deviation of the difference are <1.0 mm. (4) The measured latency is 350 ms. (5) For the tests with previously acquired patient data, the mean and standard deviation of the difference between KIM and kV/MV triangulation are <1.0 mm. Conclusions: Clinical process and QA practices for the safe clinical implementation of KIM, a novel real-time monitoring system using commonly available equipment, have been developed and implemented for prostate cancer VMAT.

Ng, J. A. [School of Medicine, University of Sydney, NSW 2006, Australia and School of Physics, University of Sydney, NSW 2006 (Australia); Booth, J. T. [School of Physics, University of Sydney, NSW 2006, Australia and Northern Sydney Cancer Centre, Royal North Shore Hospital, NSW 2065 (Australia); O’Brien, R. T.; Huang, C.-Y.; Keall, P. J., E-mail: paul.keall@sydney.edu.au [School of Medicine, University of Sydney, NSW 2006 (Australia); Colvill, E. [School of Medicine, University of Sydney, NSW 2006, Australia and Northern Sydney Cancer Centre, Royal North Shore Hospital, NSW 2065 (Australia); Poulsen, P. R. [Department of Oncology, Aarhus University Hospital, Nørrebrogade 44, Aarhus C 8000 (Denmark)

2014-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Distrbuted Sensing Systems for Water Quality Assesment and Management  

E-Print Network [OSTI]

for environmental management, and in particular, waterenvironmental management efforts at the Environmental Protection Agency (EPA), with a special focus on water-

2007-01-01T23:59:59.000Z

262

E-Print Network 3.0 - ambient water quality Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Powered by Explorit Topic List Advanced Search Sample search results for: ambient water quality Page: << < 1 2 3 4 5 > >> 1 Episodic Toxicity in the San Francisco Bay System...

263

The battle of bacteria: Agencies, stakeholders focusing on restoring water quality  

E-Print Network [OSTI]

to watershed stakeholders, who will determine the next steps in managing water quality in the tributaries. The TMDL task force was also charged with developing a roadmap for scientific research on how bacteria behave under different conditions. Tailored...

Foust, Margaret

2011-01-01T23:59:59.000Z

264

The battle of bacteria: Agencies, stakeholders focusing on restoring water quality  

E-Print Network [OSTI]

to watershed stakeholders, who will determine the next steps in managing water quality in the tributaries. The TMDL task force was also charged with developing a roadmap for scientific research on how bacteria behave under different conditions. Tailored...

Foust, Margaret

2010-01-01T23:59:59.000Z

265

A Modeling Study of the Potential Water Quality Impacts from In-Stream Tidal Energy Extraction  

SciTech Connect (OSTI)

To assess the effects of tidal energy extraction on water quality in a simplified estuarine system, which consists of a tidal bay connected to the coastal ocean through a narrow channel where energy is extracted using in-stream tidal turbines, a three-dimensional coastal ocean model with built-in tidal turbine and water quality modules was applied. The effects of tidal energy extraction on water quality were examined for two energy extraction scenarios as compared with the baseline condition. It was found, in general, that the environmental impacts associated with energy extraction depend highly on the amount of power extracted from the system. Model results indicate that, as a result of energy extraction from the channel, the competition between decreased flushing rates in the bay and increased vertical mixing in the channel directly affects water quality responses in the bay. The decreased flushing rates tend to cause a stronger but negative impact on water quality. On the other hand, the increase of vertical mixing could lead to higher bottom dissolved oxygen at times. As the first modeling effort directly aimed at examining the impacts of tidal energy extraction on estuarine water quality, this study demonstrates that numerical models can serve as a very useful tool for this purpose. However, more careful efforts are warranted to address system-specific environmental issues in real-world, complex estuarine systems.

Wang, Taiping; Yang, Zhaoqing; Copping, Andrea E.

2013-11-09T23:59:59.000Z

266

Cotton production and water quality: Economic and environmental effects of pollution prevention. Agricultural economic report  

SciTech Connect (OSTI)

Cotton production, compared with other crops, is less likely to cause erosion-induced water-quality problems because cotton acreage is not the major source of erosion in most regions. For cotton production, the most widespread potential damages to water quality are nitrates from fertilizer polluting ground water and pesticides contaminating surface water. This damage could be reduced by restricting chemical and fertilizer use on all cotton production, but doing so could reduce cotton yields and raise cotton prices. The same level of water-quality improvement could be achieved at less cost by targeting the chemical use or erosion restrictions only to cotton farms with the most vulnerable soils. Data come from a 1989 USDA survey of cotton producers.

Crutchfield, S.R.; Ribaudo, M.O.; Hansen, L.T.; Quiroga, R.

1992-12-01T23:59:59.000Z

267

Assessment of Dissolved Oxygen Mitigation at Hydropower Dams Using an Integrated Hydrodynamic/Water Quality/Fish Growth Model  

SciTech Connect (OSTI)

Dissolved oxygen (DO) in rivers is a common environmental problem associated with hydropower projects. Approximately 40% of all FERC-licensed projects have requirements to monitor and/or mitigate downstream DO conditions. Most forms of mitigation for increasing DO in dam tailwaters are fairly expensive. One area of research of the Department of Energy's Hydropower Program is the development of advanced turbines that improve downstream water quality and have other environmental benefits. There is great interest in being able to predict the benefits of these modifications prior to committing to the cost of new equipment. In the case of turbine replacement or modification, there is a need for methods that allow us to accurately extrapolate the benefits derived from one or two turbines with better design to the replacement or modification of all turbines at a site. The main objective of our study was to demonstrate a modeling approach that integrates the effects of flow and water quality dynamics with fish bioenergetics to predict DO mitigation effectiveness over long river segments downstream of hydropower dams. We were particularly interested in demonstrating the incremental value of including a fish growth model as a measure of biological response. The models applied are a suite of tools (RMS4 modeling system) originally developed by the Tennessee Valley Authority for simulating hydrodynamics (ADYN model), water quality (RQUAL model), and fish growth (FISH model) as influenced by DO, temperature, and available food base. We parameterized a model for a 26-mile reach of the Caney Fork River (Tennessee) below Center Hill Dam to assess how improvements in DO at the dam discharge would affect water quality and fish growth throughout the river. We simulated different types of mitigation (i.e., at the turbine and in the reservoir forebay) and different levels of improvement. The model application successfully demonstrates how a modeling approach like this one can be used to assess whether a prescribed mitigation is likely to meet intended objectives from both a water quality and a biological resource perspective. These techniques can be used to assess the tradeoffs between hydropower operations, power generation, and environmental quality.

Bevelhimer, Mark S [ORNL; Coutant, Charles C [ORNL

2006-07-01T23:59:59.000Z

268

Monitoring ET, Soil Moisture Saves Farmers Water, Energy, Time and Money  

E-Print Network [OSTI]

Monitoring ET, Soil Moisture Saves Farmers Water, Energy, Time and Money By Sandi Alswager Karstens, IANR News Service High energy costs mean farmers are looking for ways to reduce irrigation costs this summer. Using newer technologies such as evapotranspiration, or ET, gauges and soil moisture sensors

Nebraska-Lincoln, University of

269

Water quantity and quality model for the evaluation of water-management strategies in the Netherlands: application to the province of Friesland  

SciTech Connect (OSTI)

The Netherlands have a rather complex water-management system consisting of a number of major rivers, canals, lakes and ditches. Water-quantity management on a regional scale is necessary for an effective water-quality policy. To support water management, a computer model was developed that includes both water quality and water quantity, based on three submodels: ABOPOL for the water movement, DELWAQ for the calculation of water quality variables and BLOOM-II for the phytoplankton growth. The northern province of Friesland was chosen as a test case for the integrated model to be developed, where water quality is highly related to the water distribution and the main trade-off is minimizing the intake of (eutrophicated) alien water in order to minimize external nutrient load and maximizing the intake in order to flush channels and lakes. The results of the application of these models to this and to a number of hypothetical future situations are described.

Brinkman, J.J.; Griffioen, P.S.; Groot, S.; Los, F.J.

1987-03-01T23:59:59.000Z

270

Path-Quality Monitoring in the Presence of Adversaries (This is the full version of [21] from June 12, 2009)  

E-Print Network [OSTI]

that can make a path look better than it really is. In this paper, we design and analyze path- per, our protocols are efficient enough to run at line rate on high-speed routers. We present a secure-quality monitoring and derive analytic expressions for the trade-off between statistical accuracy and system overhead

Goldwasser, Shafi

271

Path-Quality Monitoring in the Presence of Adversaries This is the full version from March 27, 2008  

E-Print Network [OSTI]

design and analyze path-quality monitoring protocols that reliably raise an alarm when the packet threat model we consider in this pa- per, our protocols are efficient enough to run at line rate on high accuracy and system overhead. We also compare how our protocols per- form in the client-server setting

Barak, Boaz

272

Effects of Original Vegatation on Reservoir Water Quality  

E-Print Network [OSTI]

The purpose of this study was to undertake an initial step that would lead to a better understanding of the effects of nutrients released from vegetation inundated by water at newly constructed reservoirs. Specifically, a series of leaching studies...

Ball, J.; Weldon, C.; Crocker, B.

273

Decentralization and Environmental Quality: An International Analysis of Water Pollution  

E-Print Network [OSTI]

D. Political institutions and pollution control, Review ofAccounting Of?ce. Water Pollution: Differences in IssuingReal Story of the War on Air Pollution. Washington, DC: Cato

Sigman, Hilary

2009-01-01T23:59:59.000Z

274

Forage, soil and water quality responses to animal waste application  

E-Print Network [OSTI]

result in a net surplus of P and potential nutrient escape to surface waters (Dudzinsky et al. , 1983). Dairy effluent poses a lesser risk of phosphorus loading than does poultry litter since the concentration of nutrients in dairy effluent averages...

Johnson, Andrew Floyd

1995-01-01T23:59:59.000Z

275

TOXICITY OF SEDIMENTS As water quality has improved over the past three decades in  

E-Print Network [OSTI]

T TOXICITY OF SEDIMENTS Overview As water quality has improved over the past three decades in North America, diffuse sources of pollution such as storm- water runoff and sediments are now recognized as long-term, widespread pollutant sources to aquatic systems. Substantial impacts on the ecosystem from sediment

276

A Model for Predicting Daily Peak Visitation and Implications for Recreation Management and Water Quality: Evidence  

E-Print Network [OSTI]

A Model for Predicting Daily Peak Visitation and Implications for Recreation Management and Water carrying capacity. Keywords Visitation model Á Recreation management Á Water quality Á River visitation Á Clark, Fort Collins, Colorado 80523, USA 123 Environmental Management DOI 10.1007/s00267-008-9079-5 #12

277

WATER QUALITY CHANGES AS A RESULT OF COALBED METHANE DEVELOPMENT IN A ROCKY MOUNTAIN WATERSHED1  

E-Print Network [OSTI]

WATER QUALITY CHANGES AS A RESULT OF COALBED METHANE DEVELOPMENT IN A ROCKY MOUNTAIN WATERSHED1 Xixi Wang, Assefa M. Melesse, Michael E. McClain, and Wanhong Yang2 ABSTRACT: Coalbed methane (CBM the Powder River. (KEY TERMS: coalbed methane, produced water; Montana; natural gas; pattern analysis

McClain, Michael

278

In Cooperation with the National Park Service Water Quality Program Biogeochemical Processes in an Urban, Restored  

E-Print Network [OSTI]

In Cooperation with the National Park Service Water Quality Program Biogeochemical Processes in an Urban, Restored Wetland of San Francisco Bay, California, 2007­ 2009: Methods and Data for Plant, Sediment, and Water Parameters By Lisamarie Windham-Myers, Mark C. Marvin-DiPasquale, Jennifer L. Agee, Le

279

The Physics and Nuclear Nonproliferation Goals of WATCHMAN: A WAter CHerenkov Monitor for ANtineutrinos  

E-Print Network [OSTI]

This article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational status of the reactor, providing a first- ever demonstration of the potential of large Gd-doped water detectors for remote reactor monitoring for future international nuclear nonproliferation applications. During its first phase, the detector will provide a critical large-scale test of the ability to tag neutrons and thus distinguish low energy electron neutrinos and antineutrinos. This would make WATCHMAN the only detector capable of providing both direction and flavor identification of supernova neutrinos. It would also be the third largest supernova detector, and the largest underground in the western hemisphere. In a...

Askins, M; Bernstein, A; Dazeley, S; Dye, S T; Handler, T; Hatzikoutelis, A; Hellfeld, D; Jaffke, P; Kamyshkov, Y; Land, B J; Learned, J G; Marleau, P; Mauger, C; Gann, G D Orebi; Roecker, C; Rountree, S D; Shokair, T M; Smy, M B; Svoboda, R; Sweany, M; Vagins, M R; van Bibber, K A; Vogelaar, R B; Wetstein, M J; Yeh, M

2015-01-01T23:59:59.000Z

280

Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Pahranagat National Wildlife Refuge, Lincoln County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Pahranagat NWR, Beatty, Rachel, Caliente, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data on completion of the site's sampling program.

J. Englebrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2008-08-01T23:59:59.000Z

282

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Englebrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2008-08-01T23:59:59.000Z

283

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Crater Flat, Nye County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) (cover page figure) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2008-08-01T23:59:59.000Z

284

Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Crater Flat, Nye County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) (cover page figure) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S.Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

285

Letter Report: Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D Campbell; S. Campbell; S. Kohl, D. Shafer

2008-08-01T23:59:59.000Z

286

Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Tonopah Airport, Nye County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Tonopah Airport, Beatty, Rachel, Caliente, Pahranagat NWR, Crater Flat, and the Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

287

Tissue-based water quality biosensors for detecting chemical warfare agents  

DOE Patents [OSTI]

A water quality sensor for detecting the presence of at least one chemical or biological warfare agent includes: a cell; apparatus for introducing water into the cell and discharging water from the cell adapted for analyzing photosynthetic activity of naturally occurring, free-living, indigenous photosynthetic organisms in water; a fluorometer for measuring photosynthetic activity of naturally occurring, free-living, indigenous photosynthetic organisms drawn into the cell; and an electronics package that analyzes raw data from the fluorometer and emits a signal indicating the presence of at least one chemical or biological warfare agent in the water.

Greenbaum, Elias (Oak Ridge, TN); Sanders, Charlene A. (Knoxville, TN)

2003-05-27T23:59:59.000Z

288

Real-Time Water Quality Management in the Grassland Water District  

E-Print Network [OSTI]

Grassland Water District. Solar Panel with 12-volt batteryWater District. Power Solar Panel with 12-volt batteryWater District. Power Solar Panel with 12-volt battery

2004-01-01T23:59:59.000Z

289

Conceptual design of a regional water quality screening model. [RFF; Reach; HANFORD; ARQUAL; SEAS; NASQUAN  

SciTech Connect (OSTI)

This water quality assessment methodology is intended to predict concentrations at future times and to estimate the impacts on water quality of energy-related activities (including industrial boilers). Estimates of impacts on water quality at future times are based on incremental changes in pollutant inputs to the body water. Important features of the model are: use of measured concentrations to account for existing conditions; consideration of incremental changes in pollutant loads; emphasis on the energy sector and industrial boilers; analysis restricted to streams only; no attempt to fully account for pollutant behavior; and flexible design, so that future improvements can be incorporated. The basic approach is very similar to the one used by Argonne's ARQUAL model but will allow more complex pollutant behavior and more flexibility in use. (PSB)

Davis, M J

1981-01-01T23:59:59.000Z

290

NM WAIDS: A PRODUCED WATER QUALITY AND INFRASTRUCTURE GIS DATABASE FOR NEW MEXICO OIL PRODUCERS  

SciTech Connect (OSTI)

The New Mexico Water and Infrastructure Data System (NM WAIDS) seeks to alleviate a number of produced water-related issues in southeast New Mexico. The project calls for the design and implementation of a Geographical Information System (GIS) and integral tools that will provide operators and regulators with necessary data and useful information to help them make management and regulatory decisions. The major components of this system are: (1) databases on produced water quality, cultural and groundwater data, oil pipeline and infrastructure data, and corrosion information, (2) a web site capable of displaying produced water and infrastructure data in a GIS or accessing some of the data by text-based queries, (3) a fuzzy logic-based, site risk assessment tool that can be used to assess the seriousness of a spill of produced water, and (4) a corrosion management toolkit that will provide operators with data and information on produced waters that will aid them in deciding how to address corrosion issues. The various parts of NM WAIDS will be integrated into a website with a user-friendly interface that will provide access to previously difficult-to-obtain data and information. Primary attention during the first six months of this project has been focused on creating the water quality databases for produced water and surface water, along with collection of corrosion information and building parts of the corrosion toolkit. Work on the project to date includes: (1) Creation of a water quality database for produced water analyses. The database was compiled from a variety of sources and currently has over 4000 entries for southeast New Mexico. (2) Creation of a web-based data entry system for the water quality database. This system allows a user to view, enter, or edit data from a web page rather than having to directly access the database. (3) Creation of a semi-automated data capturing system for use with standard water quality analysis forms. This system improves the accuracy and speed of water quality data entry. (4) Acquisition of ground water data from the New Mexico State Engineer's office, including chloride content and TDS (Total Dissolved Solids) for over 30,000 data points in southeast New Mexico. (5) Creation of a web-based scale prediction tool, again with a web-based interface, that uses two common scaling indices (Stiff-Davis and Oddo-Thomson) to predict the likelihood of scaling. This prediction tool can either run from user input data, or the user can select samples from the water analysis database. (6) Creation of depth-to-groundwater maps for the study area. (7) Analysis of water quality data by formation. (8) Continuation of efforts to collect produced water quality information from operators in the southeast New Mexico area. (9) Qualitative assessment of produced water from various formations regarding corrosivity. (10) Efforts at corrosion education in the region through operator visits. Future work on this project will include: (11) Development of an integrated web and GIS interface for all the information collected in this effort. (12) Continued development of a fuzzy logic spill risk assessment tool that was initially developed prior to this project. Improvements will include addition of parameters found to be significant in determining the impact of a brine spill at a specific site. (13) Cleanup and integration of water quality databases. (14) Compilation of both hard copy and online corrosion toolkit material.

Martha Cather; Robert Lee; Ibrahim Gundiler; Andrew Sung; Naomi Davidson; Ajeet Kumar Reddy; Mingzhen Wei

2003-04-01T23:59:59.000Z

291

Site-Wide Integrated Water Monitoring - Defining and Implementing Sampling Objectives to Support Site Closure - 13060  

SciTech Connect (OSTI)

The Underground Test Area (UGTA) activity is responsible for assessing and evaluating the effects of the underground nuclear weapons tests on groundwater at the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), and implementing a corrective action closure strategy. The UGTA strategy is based on a combination of characterization, modeling studies, monitoring, and institutional controls (i.e., monitored natural attenuation). The closure strategy verifies through appropriate monitoring activities that contaminants of concern do not exceed the SDWA at the regulatory boundary and that adequate institutional controls are established and administered to ensure protection of the public. Other programs conducted at the NNSS supporting the environmental mission include the Routine Radiological Environmental Monitoring Program (RREMP), Waste Management, and the Infrastructure Program. Given the current programmatic and operational demands for various water-monitoring activities at the same locations, and the ever-increasing resource challenges, cooperative and collaborative approaches to conducting the work are necessary. For this reason, an integrated sampling plan is being developed by the UGTA activity to define sampling and analysis objectives, reduce duplication, eliminate unnecessary activities, and minimize costs. The sampling plan will ensure the right data sets are developed to support closure and efficient transition to long-term monitoring. The plan will include an integrated reporting mechanism for communicating results and integrating process improvements within the UGTA activity as well as between other U.S. Department of Energy (DOE) Programs. (authors)

Wilborn, Bill; Knapp, Kathryn [U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (United States)] [U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (United States); Farnham, Irene; Marutzky, Sam [Navarro-Intera (United States)] [Navarro-Intera (United States)

2013-07-01T23:59:59.000Z

292

Site-Wide Integrated Water Monitoring -- Defining and Implementing Sampling Objectives to Support Site Closure  

SciTech Connect (OSTI)

The Underground Test Area (UGTA) activity is responsible for assessing and evaluating the effects of the underground nuclear weapons tests on groundwater at the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), and implementing a corrective action closure strategy. The UGTA strategy is based on a combination of characterization, modeling studies, monitoring, and institutional controls (i.e., monitored natural attenuation). The closure strategy verifies through appropriate monitoring activities that contaminants of concern do not exceed the SDWA at the regulatory boundary and that adequate institutional controls are established and administered to ensure protection of the public. Other programs conducted at the NNSS supporting the environmental mission include the Routine Radiological Environmental Monitoring Program (RREMP), Waste Management, and the Infrastructure Program. Given the current programmatic and operational demands for various water-monitoring activities at the same locations, and the ever-increasing resource challenges, cooperative and collaborative approaches to conducting the work are necessary. For this reason, an integrated sampling plan is being developed by the UGTA activity to define sampling and analysis objectives, reduce duplication, eliminate unnecessary activities, and minimize costs. The sampling plan will ensure the right data sets are developed to support closure and efficient transition to long-term monitoring. The plan will include an integrated reporting mechanism for communicating results and integrating process improvements within the UGTA activity as well as between other U.S. Department of Energy (DOE) Programs.

Wilborn, Bill [NNSA/NFO, Nevada Site Office (United States); Farnham, Irene [Navarro-Interra LLC, Las Vegas (United States); Marutzky, Sam [Navarro-Interra LLC, Las Vegas (United States); Knapp, Kathryn [NNSA/NFO, Nevada Site Office (United States)

2013-02-24T23:59:59.000Z

293

Z .The Science of the Total Environment 260 2000 1 9 Assessing water quality impacts and cleanup  

E-Print Network [OSTI]

Z .The Science of the Total Environment 260 2000 1 9 Assessing water quality impacts and cleanup a California Regional Water Quality Control Board, 1515 Clay St., Suite 1400, Oakland, CA 94612, USA b of the Total En¨ironment 260 2000 1 92 quality trends can be more accurately measured by changes

Kirchner, James W.

294

Sensors for monitoring waste glass quality and method of using the same  

DOE Patents [OSTI]

A set of three electrical probes is described for monitoring alkali and oxygen activity of a glass melt. On-line, real time measurements of the potential difference among the probes when they are placed in electrical contact with the melt yield the activity information and can be used to adjust the composition of the melt in order to produce higher quality glass. The first two probes each has a reference gas and a reference electrolyte and a pair of wires in electrical connection with each other in the reference gas but having one of the wires extending further into the reference electrolyte. The reference gases both include a known concentration of oxygen. The third electrode has a pair of wires extending through an otherwise solid body to join electrically just past the body but having one of the wires extend past this junction. Measuring the potential difference between wires of the first and second probes provides the alkali activity; measurement of the potential difference between wires of the second and third probes provides the oxygen activity of the melt. 1 figure.

Bickford, D.F.

1994-03-15T23:59:59.000Z

295

RAPID/BulkTransmission/Water Quality | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: EnergyPotentialUrbanUtilityScalePVCapacityPulaskiRAPID/BulkTransmission/Texas <RAPID/BulkTransmission/Water

296

RAPID/Geothermal/Water Quality/Alaska | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to: navigation, search RAPID Regulatory andInformationRAPID/Geothermal/Water

297

NM WAIDS: A PRODUCED WATER QUALITY AND INFRASTRUCTURE GIS DATABASE FOR NEW MEXICO OIL PRODUCERS  

SciTech Connect (OSTI)

The New Mexico Water and Infrastructure Data System (NM WAIDS) seeks to alleviate a number of produced water-related issues in southeast New Mexico. The project calls for the design and implementation of a Geographical Information System (GIS) and integral tools that will provide operators and regulators with necessary data and useful information to help them make management and regulatory decisions. The major components of this system are: (1) Databases on produced water quality, cultural and groundwater data, oil pipeline and infrastructure data, and corrosion information. (2) A web site capable of displaying produced water and infrastructure data in a GIS or accessing some of the data by text-based queries. (3) A fuzzy logic-based, site risk assessment tool that can be used to assess the seriousness of a spill of produced water. (4) A corrosion management toolkit that will provide operators with data and information on produced waters that will aid them in deciding how to address corrosion issues. The various parts of NM WAIDS will be integrated into a website with a user-friendly interface that will provide access to previously difficult-to-obtain data and information. Primary attention during the first six months of this project was focused on creating the water quality databases for produced water and surface water, along with collecting of corrosion information and building parts of the corrosion toolkit. Work on the project to date includes: (1) Creation of a water quality database for produced water analyses. The database was compiled from a variety of sources and currently has over 7000 entries for New Mexico. (2) Creation of a web-based data entry system for the water quality database. This system allows a user to view, enter, or edit data from a web page rather than having to directly access the database. (3) Creation of a semi-automated data capturing system for use with standard water quality analysis forms. This system improves the accuracy and speed of water quality data entry. (4) Acquisition of ground water data from the New Mexico State Engineer's office, including chloride content and TDS (Total Dissolved Solids) for over 30,000 data points in southeast New Mexico. (5) Creation of a web-based scale prediction tool, again with a web-based interface, that uses two common scaling indices to predict the likelihood of scaling. This prediction tool can either run from user input data, or the user can select samples from the water analysis database. (6) Creation of depth-to-groundwater maps for the study area. (7) Analysis of water quality data by formation. (8) Continuation of efforts to collect produced water quality information from operators in the southeast New Mexico area. (9) Qualitative assessment of produced water from various formations regarding corrosivity. (10) Efforts at corrosion education in the region through operator visits. Future work on this project will include: (1) Development of an integrated web and GIS interface for all the information collected in this effort. (2) Continued development of a fuzzy logic spill risk assessment tool that was initially developed prior to this project. Improvements will include addition of parameters found to be significant in determining the impact of a brine spill at a specific site. (3) Compilation of both hard copy and online corrosion toolkit material.

Martha Cather; Robert Lee; Ibrahim Gundiler; Andrew Sung

2003-09-24T23:59:59.000Z

298

Microsoft Word - S05072_WaterQualityComplStrategy.doc  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545*. . :theWaterNRCGJTaskReview

299

ADEQ 401 Water Quality Forms | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,Information Of TheFixed Logo: ACORE Name:Forms Jump

300

Effects on the Physical Environment (Hydrodynamics, and Water Quality Food  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE: ECM Summary ECMWear |CharacteristicsEffectsWaterWeb) |

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

ARM 17-30 - Water Quality | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,InformationWind Energy JumpEnergyApplication Process0

302

Two-dimensional water quality modeling of Town Creek embayment on Guntersville Reservoir  

SciTech Connect (OSTI)

TVA investigated water quality of Town Creek embayment using a branched two-dimensional model of Guntersville Reservoir. Simulation results were compared in terms of algal biomass, nutrient concentrations, and volume of embayment with depleted dissolved oxygen. Stratification and flushing play a significant role in the embayment water quality. Storms introduce large loadings of organics, nutrients, and suspended solids. Dissolved oxygen depletion is most severe after storms followed by low flow that fails to flush the embayment. Embayment water quality responses to potential animal waste and erosion controls were explored. Modeling indicated animal waste controls were much more cost-effective than erosion controls. Erosion controls will decrease embayment suspended solids and thereby increase algal biomass due to greater light penetration. 29 refs., 16 figs., 4 tabs.

Bender, M.D.; Shiao, Ming C.; Hauser, G.E. (Tennessee Valley Authority, Norris, TN (USA). Engineering Lab.); Butkus, S.R. (Tennessee Valley Authority, Norris, TN (USA). Water Quality Dept.)

1990-09-01T23:59:59.000Z

303

Soil Water Balance and Recharge Monitoring at the Hanford Site - FY09 Status Report  

SciTech Connect (OSTI)

Recharge provides the primary driving force for transporting contaminants from the vadose zone to underlying aquifer systems. Quantification of recharge rates is important for assessing contaminant transport and fate and for evaluating remediation alternatives. This report describes the status of soil water balance and recharge monitoring performed by Pacific Northwest National Laboratory at the Hanford Site for Fiscal Year 2009. Previously reported data for Fiscal Years 2004 - 2008 are updated with data collected in Fiscal Year 2009 and summarized.

Rockhold, Mark L.; Saunders, Danielle L.; Strickland, Christopher E.; Waichler, Scott R.; Clayton, Ray E.

2009-09-28T23:59:59.000Z

304

Soil Water Balance and Recharge Monitoring at the Hanford Site – FY 2010 Status Report  

SciTech Connect (OSTI)

This report summarizes the recharge data collected in FY 2010 at five locations on the Hanford Site in southeastern Washington State. Average monthly precipitation and temperature conditions in FY 2010 were near normal and did not present an opportunity for increased recharge. The recharge monitoring data confirmed those conditions, showing normal behavior in water content, matric head, and recharge rates. Also provided in this report is a strategy for recharge estimation for the next 5 years.

Fayer, Michael J.; Saunders, Danielle L.; Herrington, Ricky S.; Felmy, Diana

2010-10-27T23:59:59.000Z

305

Factors Influencing the Adoption of Water Quality Best Management Practices by Texas Beef Cattle Producers  

E-Print Network [OSTI]

Analysis of variance ATTAINS Assessment, TMDL Tracking and Implementation System BMP Best management practice CWA Clean Water Act DOI Diffusion of innovations EPA Environmental Protection Agency EQIP Environmental Quality Incentives Program GCSP... quality. According to the US Environmental Protection Agency’s (EPA) Assessment, TMDL Tracking and Implementation System (ATTAINS) database (2013), Texas has approximately 191,000 miles of streams and rivers; nearly 2 million acres of lakes...

Peterson, Jennifer

2014-05-28T23:59:59.000Z

306

Deep in the Forests: Program works to protect water quality through forestry practices  

E-Print Network [OSTI]

20 tx H2O Winter 2011 Story by Kathy Wythe The Texas Forest Service works with forestry professionals to implement best management practices to help protect water quality, which is critical for people and wildlife to survive. Photo courtesy... of Texas Forest Service. Deep in the forests Program works to protect water quality through forestry practices Winter 2011 tx H2O 21 ] Deep in the forests of East Texas and sca#27;ered in pockets of other parts of the state are more than...

Wythe, Kathy

2011-01-01T23:59:59.000Z

307

Deep in the forests: Program works to protect water quality through forestry practices  

E-Print Network [OSTI]

20 tx H2O Winter 2011 Story by Kathy Wythe The Texas Forest Service works with forestry professionals to implement best management practices to help protect water quality, which is critical for people and wildlife to survive. Photo courtesy... of Texas Forest Service. Deep in the forests Program works to protect water quality through forestry practices Winter 2011 tx H2O 21 ] Deep in the forests of East Texas and sca#27;ered in pockets of other parts of the state are more than...

Wythe, Kathy

2011-01-01T23:59:59.000Z

308

Cherokee Reservoir: supplement to factors affecting water quality in Cherokee Reservoir  

SciTech Connect (OSTI)

Several rates and/or measurements were assumed in preparation of the Factors Affecting Water Quality in Cherokee Reservoir report prepared by Iwanski, et al. (1980). The following discussions and data were generated to support future modeling efforts of Cherokee Reservoir water quality. These discussions are not wholly intended to define conclusions or new findings, but rather lend support to assumed parameters in the modeling effort. The data include: (1) long-term BOD analyses; (2) limiting nutrient studies algal assays; (3) phytoplankton biomass; (4) primary productivity; and (5) solids transport. 10 references, 3 figures, 5 tables. (ACR)

Poppe, W.L.

1981-09-14T23:59:59.000Z

309

Potential climate change effects on Great Lakes hydrodynamics and water quality  

SciTech Connect (OSTI)

The problem of climate change has become increasingly recognized as a major environmental concern. Its impact can affect many socio-economic and ecosystem components. This book provides a state-of-the-art review of the climate change effects on lake hydrodynamics and water quality. Most of the engineering cases covered deal with the ability of existing infrastructure to cope with extreme weather conditions. The aim is to provide sufficient case studies to illustrate the advancement in modeling research on lake hydrodynamics, thermal stratification, pollutant transport and water quality by highlighting the climate change aspects in the application of these techniques.

Lam, D.C.L.; Schertzer, W.M. [eds.

1999-07-01T23:59:59.000Z

310

Provide Assistance to Improve Water Quality in Hood County Final Report  

E-Print Network [OSTI]

popul ati o n . There are an estima te d 9,000 septic tanks located around Lake Granbur y , with absorpt i o n fields install e d on small lots in close proximi t y to the lake. Most of the i nhabit e d areas around the lake exist on man-ma d e... Upon the Water Quality of the Lake Study identi fi e d the most notab l e area of c oncer n to be in the man- ma d e coves. In 1995 a study titled, Survey of Conditions and Impact of Septic Tank Pollution on the Water Quality in Lake Granbury...

Lesikar, Bruce; Mechell, Justin; Clayton, Brent; Gerlich, Ryan; Kalisek, Danielle; Harris, B.L.

311

Water quality changes as a result of coalbed methane development in a Rocky mountain watershed  

SciTech Connect (OSTI)

Coalbed methane (CBM) development raises serious environmental concerns. In response, concerted efforts have been made to collect chemistry, salinity, and sodicity data on CBM produced water. However, little information on changes of stream water quality resulting from directly and/or indirectly received CBM produced water is available in the literature. The objective of this study was to examine changes in stream water quality, particularly sodicity and salinity, due to CBM development in the Powder River watershed, which is located in the Rocky Mountain Region and traverses the states of Wyoming and Montana. To this end, a retrospective analysis of water quality trends and patterns was conducted using data collected from as early as 1946 up to and including 2002 at four U.S. Geological Survey gauging stations along the Powder River. Trend analysis was conducted using linear regression and Seasonal Kendall tests, whereas, Tukey's test for multiple comparisons was used to detect changes in the spatial pattern. The results indicated that the CBM development adversely affected the water quality in the Powder River. First, the development elevated the stream sodicity, as indicated by a significant increase trend of the sodium adsorption ratio. Second, the development tended to shrink the water quality differences among the three downstream stations but to widen the differences between these stations and the farthest upstream station. In contrast, the development had only a minor influence on stream salinity. Hence, the CBM development is likely an important factor that can be managed to lower the stream sodicity. The management may need to take into account that the effects of the CBMdevelopment were different from one location to another along the Powder River.

Wang, X.; Melesse, A.M.; McClain, M.E.; Yang, W. [Tarleton State University, Stephenville, TX (USA)

2007-12-15T23:59:59.000Z

312

Water quality in the vicinity of Fenton Hill: Progress report, 1983 and 1984  

SciTech Connect (OSTI)

Water quality data have been collected since 1974 from established surface and groundwater stations at and in the vicinity of Fenton Hill (Hot Dry Rock Geothermal Demonstration Site) located in the Jemez Mountains. This is part of a continued program of environmental studies. There has been a slight variation in chemical quality of water from the surface and groundwater stations; however, these variations are within normal seasonal fluctuations. Water supply at the site is pumped from the aquifer in the Abiquiu Tuff. Cumulative production from 1976 through 1984 has been 41.5 x 10/sup 6/ gal. The water level in the supply well declined from 365 ft in 1976 to 379 ft in 1984.

Purtymun, W.D.; Ferenbaugh, R.W.; Becker, N.M.; Williams, M.C.; Maes, M.

1987-01-01T23:59:59.000Z

313

A water quality characterization of a tidally influenced flood control canal of Galveston Bay, Texas  

E-Print Network [OSTI]

H), specific conductance, sulfide, total organic carbon (TOC), and turbidity samples were collected at seven stations in HBDC and from the effluent of two municipal wastewater treatment plants (MWTP) discharging into HBDC in order to detect significant... to MWTP outfall. Specific conductance patterns mirrored salinity trends. TOC levels showed a steady bayward decrease. Turbidity levels were consistently highest in bottom waters. No trends were apparent for COD, pH, and sulfide. HBDC water quality...

Polasek, Jeffrey Steven

1992-01-01T23:59:59.000Z

314

Interim site characterization report and ground-water monitoring program for the Hanford site solid waste landfill  

SciTech Connect (OSTI)

Federal and state regulations governing the operation of landfills require utilization of ground-water monitoring systems to determine whether or not landfill operations impact ground water at the point of compliance (ground water beneath the perimeter of the facility). A detection-level ground-water monitoring system was designed, installed, and initiated at the Hanford Site Solid Waste Landfill (SWL). Chlorinated hydrocarbons were detected at the beginning of the ground-water monitoring program and continue to be detected more than 1 year later. The most probable source of the chlorinated hydrocarbons is washwater discharged to the SWL between 1985 and 1987. This is an interim report and includes data from the characterization work that was performed during well installation in 1987, such as field observations, sediment studies, and geophysical logging results, and data from analyses of ground-water samples collected in 1987 and 1988, such as field parameter measurements and chemical analyses. 38 refs., 27 figs., 8 tabs.

Fruland, R.M.; Hagan, R.A.; Cline, C.S.; Bates, D.J.; Evans, J.C.; Aaberg, R.L.

1989-07-01T23:59:59.000Z

315

Effects of land disposal of municipal sewage sludge on soil, streambed sediment, and ground- and surface-water quality at a site near Denver, Colorado  

SciTech Connect (OSTI)

The report describes the effects of burial and land application of municipal sewage sludge on soil and streambed sediment and water quality in the underlying aquifers and surface water within and around the Lowry sewage-sludge-disposal area. The existing ground-water observation-well network at the disposal area was expanded for the study. Surface-water-sampling sites were selected so that runoff could be sampled from intense rainstorms or snowmelt. The sampling frequency for ground-water and surface-water runoff was changed from yearly to quarterly, and soil samples were collected. Four years of data were collected from 1984 to 1987 during the expanded monitoring program at the Lowry sewage-sludge-disposal area. These data, in addition to the data collected by the U.S. Geological Survey from 1981 to 1983, were used to determine effects of sewage-sludge-disposal on soil and streambed sediment and surface- and ground-water quality at the disposal area.

Gaggiani, N.G.

1991-01-01T23:59:59.000Z

316

Towards benchmarking an in-stream water quality model Hydrol. Earth Syst. Sci., 11(1), 623633, 2007  

E-Print Network [OSTI]

. The project Benchmark Models for the Water Framework Directive (BMW, project website address http:// www.environment. This latter process is benchmarking. The BMW project considers models, primarily of water quality, categorised

Paris-Sud XI, Université de

317

Monitoring  

SciTech Connect (OSTI)

The invention provides apparatus and methods which facilitate movement of an instrument relative to an item or location being monitored and/or the item or location relative to the instrument, whilst successfully excluding extraneous ions from the detection location. Thus, ions generated by emissions from the item or location can successfully be monitored during movement. The technique employs sealing to exclude such ions, for instance, through an electro-field which attracts and discharges the ions prior to their entering the detecting location and/or using a magnetic field configured to repel the ions away from the detecting location.

Orr, Christopher Henry (Calderbridge, GB); Luff, Craig Janson (Calderbridge, GB); Dockray, Thomas (Calderbridge, GB); Macarthur, Duncan Whittemore (Los Alamos, NM)

2004-11-23T23:59:59.000Z

318

Elements of an environmental decision support system for seasonal wetland salt management in a river basin subjected to water quality regulation  

SciTech Connect (OSTI)

Seasonally managed wetlands in the Grasslands Basin on the west-side of California's San Joaquin Valley provide food and shelter for migratory wildfowl during winter months and sport for waterfowl hunters during the annual duck season. Surface water supply to these wetlands contain salt which, when drained to the San Joaquin River during the annual drawdown period, can negatively impact water quality and cause concern to downstream agricultural riparian water diverters. Recent environmental regulation, limiting discharges salinity to the San Joaquin River and primarily targeting agricultural non-point sources, now also targets return flows from seasonally managed wetlands. Real-time water quality management has been advocated as a means of continuously matching salt loads discharged from agricultural, wetland and municipal operations to the assimilative capacity of the San Joaquin River. Past attempts to build environmental monitoring and decision support systems (EDSS's) to implement this concept have enjoyed limited success for reasons that are discussed in this paper. These reasons are discussed in the context of more general challenges facing the successful implementation of a comprehensive environmental monitoring, modelling and decision support system for the San Joaquin River Basin.

Quinn, N.W.T.

2009-06-01T23:59:59.000Z

319

YSI Blue-Green Algae (BGA) Sensors Spatial Water Quality Mapping of the Potomac River Estuary  

E-Print Network [OSTI]

YSI Blue-Green Algae (BGA) Sensors Spatial Water Quality Mapping of the Potomac River Estuary Visit integrated Yellow Spring Instruments (YSI) blue- green algae (BGA) sensors into our system to evaluate of Microcystis aeruginosa. We compared interpolated results of traditional chlorophyll sensors with the BGA data

Boynton, Walter R.

320

Water quality criteria for colored smokes: Solvent Yellow 33, Final report. [Contains glossary  

SciTech Connect (OSTI)

The available data on the environmental fate, aquatic toxicity, and mammalian toxicity of Solvent Yellow 33, a quinoline dye used in colored smoke grenades, were reviewed. The US Environmental Protection Agency (USEPA) guidelines were used in an attempt to generate water quality criteria for the protection of aquatic life and its use and of human health. 87 refs., 2 figs., 13 tabs.

Davidson, K.A.; Hovatter, P.S.

1987-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Impacts of Shale Gas Wastewater Disposal on Water Quality in Western Pennsylvania  

E-Print Network [OSTI]

Impacts of Shale Gas Wastewater Disposal on Water Quality in Western Pennsylvania Nathaniel R. In Pennsylvania, oil and gas wastewater is sometimes treated at brine treatment facilities and discharged to local bioaccumulation in localized areas of shale gas wastewater disposal. INTRODUCTION The safe disposal of large

Jackson, Robert B.

322

An environmental sensor network to determine drinking water quality and security  

E-Print Network [OSTI]

An environmental sensor network to determine drinking water quality and security Anastassia. Small Civil & Environmental Engineering and Engineering & Public Policy Carnegie Mellon University ms35@andrew.cmu.edu Jeanne VanBriesen Civil and Environmental Engineering and Biomedical Engineering Carnegie

Ailamaki, Anastassia

323

Prediction of postmine ground-water quality at a Texas surface lignite mine  

E-Print Network [OSTI]

. The predominant factors which affect spoil water quality have not been completely identified to date. Therefore, the Gibbons Creek Lignite Mine in Grimes County, Texas was chosen as a test site to evaluate the potential factors that can affect the geochemical...

Wise, Clifton Farrell

1995-01-01T23:59:59.000Z

324

Upper Middle Mainstem Columbia River Subbasin Water Quality Parameters Affected by Hydropower Production  

E-Print Network [OSTI]

Appendix E Upper Middle Mainstem Columbia River Subbasin Water Quality Parameters Affected have reappeared as management agencies have reinstituted spill as a means of aiding downstream fish passage throughout the system. The WDOE has set a TDG standard of 110 percent of saturation for all

325

Evaluation of chemical sensors for in situ ground-water monitoring at the Hanford Site  

SciTech Connect (OSTI)

This report documents a preliminary review and evaluation of instrument systems and sensors that may be used to detect ground-water contaminants in situ at the Hanford Site. Three topics are covered in this report: (1) identification of a group of priority contaminants at Hanford that could be monitored in situ, (2) a review of current instrument systems and sensors for environmental monitoring, and (3) an evaluation of instrument systems that could be used to monitor Hanford contaminants. Thirteen priority contaminants were identified in Hanford ground water, including carbon tetrachloride and six related chlorinated hydrocarbons, cyanide, methyl ethyl ketone, chromium (VI), fluoride, nitrate, and uranium. Based on transduction principles, chemical sensors were divided into four classes, ten specific types of instrument systems were considered: fluorescence spectroscopy, surface-enhanced Raman spectroscopy (SERS), spark excitation-fiber optic spectrochemical emission sensor (FOSES), chemical optrodes, stripping voltammetry, catalytic surface-modified ion electrode immunoassay sensors, resistance/capacitance, quartz piezobalance and surface acoustic wave devices. Because the flow of heat is difficult to control, there are currently no environmental chemical sensors based on thermal transduction. The ability of these ten instrument systems to detect the thirteen priority contaminants at the Hanford Site at the required sensitivity was evaluated. In addition, all ten instrument systems were qualitatively evaluated for general selectivity, response time, reliability, and field operability. 45 refs., 23 figs., 7 tabs.

Murphy, E.M.; Hostetler, D.D.

1989-03-01T23:59:59.000Z

326

Geosynthetic Filters for Water Quality Improvement of Urban Storm Water Runoff  

E-Print Network [OSTI]

water treatment are retention ponds, detention basins, wetland ponds, and grass swales (Strecker et al are common subsurface storm water runoff treatment systems used in urban areas. Large subsurface fil- ters the treatment system (SEMCOG 2008). Removal of filtration media such as sand is highly labor

Aydilek, Ahmet

327

Numerically Simulating the Hydrodynamic and Water Quality Environment for Migrating Salmon in the Lower Snake River, 2002-2003 Technical Report.  

SciTech Connect (OSTI)

Summer temperatures in the Lower Snake River can be altered by releasing cold waters that originate from deep depths within Dworshak Reservoir. These cold releases are used to lower temperatures in the Clearwater and Lower Snake Rivers and to improve hydrodynamic and water quality conditions for migrating aquatic species. This project monitored the complex three-dimensional hydrodynamic and thermal conditions at the Clearwater and Snake River confluence and the processes that led to stratification of Lower Granite Reservoir (LGR) during the late spring, summer, and fall of 2002. Hydrodynamic, water quality, and meteorological conditions around the reservoir were monitored at frequent intervals, and this effort is continuing in 2003. Monitoring of the reservoir is a multi-year endeavor, and this report spans only the first year of data collection. In addition to monitoring the LGR environment, a three-dimensional hydrodynamic and water quality model has been applied. This model uses field data as boundary conditions and has been applied to the entire 2002 field season. Numerous data collection sites were within the model domain and serve as both calibration and validation locations for the numerical model. Errors between observed and simulated data varied in magnitude from location to location and from one time to another. Generally, errors were small and within expected ranges, although, as additional 2003 field data becomes available, model parameters may be improved to minimize differences between observed and simulated values. A two-dimensional, laterally-averaged hydrodynamic and water quality model was applied to the three reservoirs downstream of LGR (the pools behind Little Goose, Lower Monumental, and Ice Harbor Dams). A two-dimensional model is appropriate for these reservoirs because observed lateral thermal variations during summer and fall 2002 were almost negligible; however, vertical thermal variations were quite large (see USACE 2003). The numerical model was applied to each reservoir independently to simulate the time period between May 1 and October 1, 2002. Differences between observed and simulated data were small, although improvements to model coefficients may be performed as additional thermal data, collected in the reservoirs during 2003, becomes available.

Cook, C.; Richmond, M.; Coleman, A. (Pacific Northwest National Laboratory)

2003-06-01T23:59:59.000Z

328

Puget Sound Dissolved Oxygen Modeling Study: Development of an Intermediate Scale Water Quality Model  

SciTech Connect (OSTI)

The Salish Sea, including Puget Sound, is a large estuarine system bounded by over seven thousand miles of complex shorelines, consists of several subbasins and many large inlets with distinct properties of their own. Pacific Ocean water enters Puget Sound through the Strait of Juan de Fuca at depth over the Admiralty Inlet sill. Ocean water mixed with freshwater discharges from runoff, rivers, and wastewater outfalls exits Puget Sound through the brackish surface outflow layer. Nutrient pollution is considered one of the largest threats to Puget Sound. There is considerable interest in understanding the effect of nutrient loads on the water quality and ecological health of Puget Sound in particular and the Salish Sea as a whole. The Washington State Department of Ecology (Ecology) contracted with Pacific Northwest National Laboratory (PNNL) to develop a coupled hydrodynamic and water quality model. The water quality model simulates algae growth, dissolved oxygen, (DO) and nutrient dynamics in Puget Sound to inform potential Puget Sound-wide nutrient management strategies. Specifically, the project is expected to help determine 1) if current and potential future nitrogen loadings from point and non-point sources are significantly impairing water quality at a large scale and 2) what level of nutrient reductions are necessary to reduce or control human impacts to DO levels in the sensitive areas. The project did not include any additional data collection but instead relied on currently available information. This report describes model development effort conducted during the period 2009 to 2012 under a U.S. Environmental Protection Agency (EPA) cooperative agreement with PNNL, Ecology, and the University of Washington awarded under the National Estuary Program

Khangaonkar, Tarang; Sackmann, Brandon S.; Long, Wen; Mohamedali, Teizeen; Roberts, Mindy

2012-10-01T23:59:59.000Z

329

Water quality analysis of the piped water supply in Tamale, Ghana  

E-Print Network [OSTI]

The United Nation's Millennium Development Goal Target 7.C is to "halve, by 2015, the proportion of the population without sustainable access to safe drinking water". While the UN claimed to have met this goal, studies ...

Hansen, Allison Jean

2014-01-01T23:59:59.000Z

330

High-frequency precipitation and stream water quality time series from Plynlimon, Wales: an openly accessible data  

E-Print Network [OSTI]

High-frequency precipitation and stream water quality time series from Plynlimon, Wales: an openly Colin Vincent,6 Kathryn Lehto,6 Simon Grant,2 Jeremy Williams,7 Margaret Neal,1 Heather Wickham,1 Sarah-element high- frequency water quality data set that is openly accessible to the research community. The data

Kirchner, James W.

331

Modeling hydrologic and water quality extremes in a changing climate: A statistical approach based on extreme value theory  

E-Print Network [OSTI]

Modeling hydrologic and water quality extremes in a changing climate: A statistical approach based on extreme value theory Erin Towler,1,2 Balaji Rajagopalan,1,3 Eric Gilleland,2 R. Scott Summers,1 David makes quantifying changes to hydrologic extremes, as well as associated water quality effects

Katz, Richard

332

It's worth the work: Proposed water quality standards move Texas closer to cleaner waters  

E-Print Network [OSTI]

are realizing that applying a single standard of primary contact recreation to hundreds of different surface water bodies may not be realistic or beneficial. While public interest is high in having an ambitious standard as possible, Jim Davenport, technical...- ation and non-contact recreation?to four, adding two more levels: secondary contact 1 and 2 (see definitions on page 19). The agency is also proposing different numerical criteria for E. coli that will be applicable in fresh water based...

Wythe, Kathy

2010-01-01T23:59:59.000Z

333

Evaluation of Calendar Year 1996 groundwater and surface water quality data for the Bear Creek Hydrogeologic Regime at the US Department of Energy Y-12 Plant, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

This report presents an evaluation of the groundwater monitoring data obtained in the Bear Creek Hydrogeologic Regime (Bear Creek Regime) during calendar year (CY) 1996. The monitoring data were collected for the multiple programmatic purposes of the Y-12 Plant Groundwater Protection Program (GWPP) and have been reported in Calendar Year 1996 Annual Groundwater Monitoring Report for the Bear Creek Hydrogeologic Regime at the US Department of Energy Y-12 Plant, Oak Ridge, Tennessee. The Annual Monitoring report presents only the results of the monitoring data evaluations required for waste management sites addressed under the Resource Conservation and Recovery Act (RCRA) post-closure permit for the Bear Creek Regime. The Annual Monitoring Report also serves as a consolidated reference for the groundwater and surface water monitoring data obtained throughout the Bear Creek Regime under the auspices of the Y-12 GWPP. This report provides an evaluation of the CY 1996 monitoring data with an emphasis on regime-wide groundwater and surface water quality and long-term concentration trends of regulated and non-regulated monitoring parameters.

NONE

1997-08-01T23:59:59.000Z

334

Ground Water Surveillance Monitoring Implementation Guide for Use with DOE O 450.1, Environmental Protection Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide assists DOE sites in establishing and maintaining surveillance monitoring programs to detect future impacts on ground water resources from site operations, to track existing ground water contamination, and to assess the potential for exposing the general public to site releases. Canceled by DOE N 251.82.

2004-06-24T23:59:59.000Z

335

The Physics and Nuclear Nonproliferation Goals of WATCHMAN: A WAter CHerenkov Monitor for ANtineutrinos  

E-Print Network [OSTI]

This article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational status of the reactor, providing a first- ever demonstration of the potential of large Gd-doped water detectors for remote reactor monitoring for future international nuclear nonproliferation applications. During its first phase, the detector will provide a critical large-scale test of the ability to tag neutrons and thus distinguish low energy electron neutrinos and antineutrinos. This would make WATCHMAN the only detector capable of providing both direction and flavor identification of supernova neutrinos. It would also be the third largest supernova detector, and the largest underground in the western hemisphere. In a follow-on phase incorporating the IsoDAR neutrino beam, the detector would have world-class sensitivity to sterile neutrino signatures and to non-standard electroweak interactions (NSI). WATCHMAN will also be a major, U.S. based integration platform for a host of technologies relevant for the Long-Baseline Neutrino Facility (LBNF) and other future large detectors. This white paper describes the WATCHMAN conceptual design,and presents the results of detailed simulations of sensitivity for the project's nonproliferation and physics goals. It also describes the advanced technologies to be used in WATCHMAN, including high quantum efficiency photomultipliers, Water-Based Liquid Scintillator (WbLS), picosecond light sensors such as the Large Area Picosecond Photo Detector (LAPPD), and advanced pattern recognition and particle identification methods.

M. Askins; M. Bergevin; A. Bernstein; S. Dazeley; S. T. Dye; T. Handler; A. Hatzikoutelis; D. Hellfeld; P. Jaffke; Y. Kamyshkov; B. J. Land; J. G. Learned; P. Marleau; C. Mauger; G. D. Orebi Gann; C. Roecker; S. D. Rountree; T. M. Shokair; M. B. Smy; R. Svoboda; M. Sweany; M. R. Vagins; K. A. van Bibber; R. B. Vogelaar; M. J. Wetstein; M. Yeh

2015-02-04T23:59:59.000Z

336

Ground water elevation monitoring at the Uranium Mill Tailings Remedial Action Salt Lake City, Utah, Vitro processing site  

SciTech Connect (OSTI)

In February 1994, a ground water level monitoring program was begun at the Vitro processing site. The purpose of the program was to evaluate how irrigating the new golf driving range affected ground water elevations in the unconfined aquifer. The program also evaluated potential impacts of a 9-hole golf course planned as an expansion of the driving range. The planned golf course expansion would increase the area to be irrigated and, thus, the water that could infiltrate the processing site soil to recharge the unconfined aquifer. Increased water levels in the aquifer could alter the ground water flow regime; contaminants in ground water could migrate off the site or could discharge to bodies of surface water in the area. The potential effects of expanding the golf course have been evaluated, and a report is being prepared. Water level data obtained during this monitoring program indicate that minor seasonal mounding may be occurring in response to irrigation of the driving range. However, the effects of irrigation appear small in comparison to the effects of precipitation. There are no monitor wells in the area that irrigation would affect most; that data limitation makes interpretations of water levels and the possibility of ground water mounding uncertain. Limitations of available data are discussed in the conclusion.

NONE

1995-04-01T23:59:59.000Z

337

System and method for monitoring water content or other dielectric influences in a medium  

DOE Patents [OSTI]

A sensor system is provided that measures water content or other detectable properties in a medium along the entire length of the sensor at any point in time. The sensor system includes an electromagnetic signal generator and a transmission line disposed in a medium to be monitored. Alternatively, the transmission line can be configured for movement across a medium to be monitored, or the transmission line can be fixed relative to a moving medium being monitored. A signal is transmitted along the transmission line at predetermined frequencies, and the signal is returned back along the transmission line and/or into an optional receive line in proximity to the transmission line. The returned signal is processed to generate a one-dimensional data output profile that is a function of a detectable property of the medium. The data output profile can be mapped onto a physical system to generate a two-dimensional or three-dimensional profile if desired. The sensor system is useful in a variety of different applications such as agriculture, horticulture, biofiltration systems for industrial offgases, leak detection in landfills or drum storage facilities at buried waste sites, and in many other applications.

Cherry, Robert S. (Idaho Falls, ID); Anderson, Allen A. (Firth, ID)

2001-01-01T23:59:59.000Z

338

The CitiSense Air Quality Monitoring Mobile Sensor Node Piero Zappi, Elizabeth Bales, Jing Hong Park, William Griswold and Tajana Simuni Rosing  

E-Print Network [OSTI]

conditions than the national ambient air quality standard [1]. Current air pollutant measurement networks. For example, The San Diego Air Pollution Control District (SDAPCD) maintains only five air pollutant samplingThe CitiSense Air Quality Monitoring Mobile Sensor Node Piero Zappi, Elizabeth Bales, Jing Hong

Simunic, Tajana

339

Monitoring indoor air quality in French schools and day-care centres. Results from the first phase of a pilot survey.  

E-Print Network [OSTI]

. KEYWORDS Air pollution, air stuffiness, formaldehyde, benzene. 1 INTRODUCTION Indoor air quality to determine an air stuffiness index as an indirect mean to assess pollutants accumulation in a closed spaceMonitoring indoor air quality in French schools and day-care centres. Results from the first phase

Boyer, Edmond

340

Groundwater quality monitoring well installation for Lower Waste Area Grouping 2 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program  

SciTech Connect (OSTI)

This report documents the drilling and installation of 11 groundwater quality monitoring (GQM) wells on the perimeter of Lower Waste Area Grouping (WAG) 2. Lower WAG 2 consists of White Oak Lake and the embayment below White Oak Dam above the Clinch River. The wells in Lower WAG 2 were drilled and developed between December 1989 and September 1990. These wells were installed to characterize and assess the WAG in accordance with applicable Department of Energy, state, and Environmental Protection Agency regulatory requirements. The wells at Lower WAG 2 were drilled with auger or air rotary rigs. Depending on the hydrogeologic conditions present at each proposed well location, one of three basic installation methods was utilized. Detailed procedures for well construction were specified by the Engineering Division to ensure that the wells would provide water samples representative of the aquifer. To ensure conformance with the specifications, Energy Systems Construction Engineering and ERCE provided continuous oversight of field activities. The purpose of the well installation program was to install GQM wells for groundwater characterization at Lower WAG 2. Data packages produced during installation activities by the ERCE hydrogeologists are an important product of the program. These packages document the well drilling, installation, and development activities and provide valuable data for well sampling and WAG characterization. The forms contained in the packages include predrilling and postdrilling checklists, drilling and construction logs, development and hydraulic conductivity records, and quality control-related documents.

Mortimore, J.A.; Lee, T.A.

1994-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Water quality and urban runoff in selected canal communities along the Texas coast  

E-Print Network [OSTI]

at points along the canal. There are data included in this report on monthly canal water quality for the seven study areas. Samples were analyzed for coli- forms, nitrite, nitrate, Kjeldahl nitrogen (organic nitrogen), phos- phates, TOC, BOD , dissolved..., temperature and salinity profiles, and Rhodamine dye dis- placement. The purpose of this report is to evaluate the sources of pollu- tional loading within the study communities . These data along with information from the literature on coastal canals...

Messenger, Allen Lester

1979-01-01T23:59:59.000Z

342

Air Quality  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Why Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data...

343

5 CCR 1002-42 Site Specific Water Quality Standards for Ground Water | Open  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights, Substantive Jump to:Species |2008 |44 Basic Standards

344

Feasibility of Using Measurements of Internal Components of Tankless Water Heaters for Field Monitoring of Energy and Water Use  

E-Print Network [OSTI]

Test Procedures for Water Heaters; Final Rule," FederalTesting of Tankless Gas Water Heater Performance," DavisInc. , "T-K2 Instantaneous Water Heater Installation Manual

Lutz, Jim

2008-01-01T23:59:59.000Z

345

Water quality effects of tire chip fills placed above the groundwater table  

SciTech Connect (OSTI)

Two field trials were constructed to investigate the effect on water quality of tire chip fills placed above the groundwater table. Control wells were used to distinguish the substances naturally present in groundwater from those that leached from tire chips. There was no evidence that tire chips increased the level of substances that have a primary drinking water standard. In addition, there was no evidence that tire chips increased the levels of aluminum, zinc, chloride or sulfate which have secondary (aesthetic) drinking water standards. Under some conditions iron levels may exceed their secondary standard. It is likely that manganese levels will exceed their secondary standard, however, manganese is naturally present in groundwater in many areas. Two sets of samples were tested for organics. Results were below the method detection limit for all compounds.

Humphrey, D.N.; Katz, L.E. [Univ. of Maine, Orono, ME (United States). Dept. of Civil and Environmental Engineering; Blumenthal, M. [Scrap Tire Management Council, Washington, DC (United States)

1997-12-31T23:59:59.000Z

346

Use of caged fish for mariculture and environmental monitoring in a power-plant cooling-water system  

E-Print Network [OSTI]

-nydrocarbon pesticides in fishes cultured at various locations within the cooling system. 203 LIST OF FIGURES Figure Page Map of the research site ~g the location of the power plant, cooling-water system, and research facilities 17 Schematic representation... quality might conceivably be available considering the large number of power plants utilizing coastal waters for cooling. Other important benefits of thermal fish-culture include ample water supply, and reduced pumping costs as a result of the massive...

Chamberlain, George William

2012-06-07T23:59:59.000Z

347

Real-time Air Quality Monitoring Through Mobile Sensing in Metropolitan Areas  

E-Print Network [OSTI]

. General Terms Measurement, Design, Experimentation, Human Factors. Keywords Air Quality, Pollution, Urban levels in the urban and suburban settings. According to the US EPA [3], the six common air pollutants. These are called the criteria pollutants and thus are required to be measured to tell us how healthy the air

Iftode, Liviu

348

Air Quality Monitoring with SensorMap Pter Vlgyesi, Andrs Ndas, Xenofon Koutsoukos, kos Ldeczi  

E-Print Network [OSTI]

and for charging the integrated Li-ion battery. The battery life of the device is limited to a few hours (in active factors affecting the quality of life and the health of the increasingly urban population of industrial cable. This wired interface can also provide power to the board both for on-line operation

Koutsoukos, Xenofon D.

349

Environmental Monitoring Plan: Environmental Monitoring Section. Appendix A, Procedures  

SciTech Connect (OSTI)

This document presents information about the environmental monitoring program at Lawrence Livermore National Laboratory. Topics discussed include: air sampling; air tritium calibrations; storm water discharge; non-storm water discharge; sampling locations; ground water sampling; noise and blast forecasting; analytical laboratory auditing; document retention; procedure writing; quality assurance programs for sampling; soil and sediment sampling; sewage sampling; diversion facility tank sampling; vegetation and foodstuff sampling; and radiological dose assessments.

NONE

1995-02-01T23:59:59.000Z

350

Use of global navigation satellite systems for monitoring deformations of water-development works  

SciTech Connect (OSTI)

The feasibility of using global radio-navigation satellite systems (GNSS) to improve functional safety of high-liability water-development works - dams at hydroelectric power plants, and, consequently, the safety of the population in the surrounding areas is examined on the basis of analysis of modern publications. Characteristics for determination of displacements and deformations with use of GNSS, and also in a complex with other types of measurements, are compared. It is demonstrated that combined monitoring of deformations of the ground surface of the region, and engineering and technical structures is required to ensure the functional safety of HPP, and reliable metrologic assurance of measurements is also required to obtain actual characteristics of the accuracy and effectiveness of GNSS observations.

Kaftan, V. I. [Russian Academy of Sciences, Geophysical Center (Russian Federation); Ustinov, A. V. [JSC Institut Gidropreoekt (Russian Federation)

2013-05-15T23:59:59.000Z

351

Bio-energy feedstock yields and their water quality benefits in Mississippi  

SciTech Connect (OSTI)

Cellulosic and agricultural bio-energy crops can, under careful management, be harvested as feedstock for bio-fuels production and provide environmental benefits. However, it is required to quantify their relative advantages in feedstock production and water quality. The primary objective of this research was to evaluate potential feedstock yield and water quality benefit scenarios of bioenergy crops: Miscanthus (Miscanthus-giganteus), Switchgrass (Panicum virgatum), Johnsongrass (Sorghum halepense), Alfalfa (Medicago sativa L.), Soybean {Glycine max (L.) Merr.}, and Corn (Lea mays) in the Upper Pearl River watershed (UPRW), Mississippi using a Soil and Water Assessment Tool (SWAT). The SWAT model was calibrated (January 1981 to December 1994) and validated (January 1995 to September 2008) using monthly measured stream flow data. The calibrated and validated model determined good to very good performance for stream flow prediction (R2 and E from 0.60 to 0.86). The RMSE values (from 14 m3 s-1 to 37 m3 s-1) were estimated at similar levels of errors during model calibration and validation. The long-term average annual potential feedstock yield as an alternative energy source was determined the greatest when growing Miscanthus grass (373,849 Mg) as followed by Alfalfa (206,077 Mg), Switchgrass (132,077 Mg), Johnsongrass (47,576 Mg), Soybean (37,814 Mg), and Corn (22,069 Mg) in the pastureland and cropland of the watershed. Model results determined that average annual sediment yield from the Miscanthus grass scenario determined the least (1.16 Mg/ha) and corn scenario the greatest (12.04 Mg/ha). The SWAT model simulated results suggested that growing Miscanthus grass in the UPRW would have the greatest potential feedstock yield and water quality benefits.

Parajuli, Prem B.

2011-08-10T23:59:59.000Z

352

D.C. Water Resources Research Center Annual Technical Report  

E-Print Network [OSTI]

of Storm and Wastewater Management. The Water Quality Testing Lab has allowed the Institute and the Water as a predictive tool for water resource management. Integrating monitoring and mathematical modeling, both labs as well weed control in urban gardening. The Cooperative Extension Service/Water Quality Education Program

353

Community Environmental Monitoring Program (CEMP) Data related to Air, Soil, and Water Monitoring around the Nevada Test Site  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The Community Environmental Monitoring Program (CEMP) is a network of 29 monitoring stations located in communities surrounding and downwind of the Nevada Test Site (NTS) that monitor the airborne environment for manmade radioactivity that could result from NTS activities. The network stations, located in Nevada, Utah, and California are comprised of instruments that collect a variety of environmental radiological and meteorological data. The emphasis of the CEMP is to monitor airborne radioactivity and weather conditions, and make the results available to the public. Instrumentation that records these data is connected to a datalogger, and real-time radiation levels or weather conditions can immediately and easily be seen on a display at each station. These data are transmitted via direct or wireless internet connection, landline or cellular phone, or satellite transmission to DRI's Western Regional Climate Center in Reno, Nevada, and are updated as frequently as every 10 minutes on the World Wide Web at http://www.cemp.dri.edu. DOE and DRI also publish the results of the monitoring program and distribute these reports throughout the network community. The reports provide summaries of average values for each station and the entire network, and show deviations from the expected range values. [Copied from the CEMP website (Introduction) at http://www.cemp.dri.edu/cemp/moreinfo.html

354

Up-Stream Dissolved Oxygen TMDL Project Quality Assurance ProjectPlan  

SciTech Connect (OSTI)

A quality assurance project plan (QAPP) for the execution of an ecosystem level monitoring and research program examining algal ecology in highly impaired rivers. Procedures for executing both field and laboratory surface water quality and flow analysis are described. The procedures described here are compatible with the California Surface Water Ambient Monitoring program (SWAMP).

Stringfellow, William T.

2005-05-13T23:59:59.000Z

355

Assessment of Stormflow and Water Quality from Undisturbed and Site Prepared Forest Land in East Texas (Interim Report)  

E-Print Network [OSTI]

TR- 117 1981 Assessment of Stormflow and Water Quality from Undisturbed and Site Prepared Forest Land in East Texas, Interim Report M.G. DeHaven W.H. Blackburn R.W. Knight A.T. Weichert...

DeHaven, M. G.; Blackburn, W. H.; Knight, R. W.; Weichert, A. T.

356

Effect of Forest Site Preparation and Livestock Grazing on Stormflow and Water Quality in the South East  

E-Print Network [OSTI]

of Texas. However, little is known about the influence of intensive forest practices or livestock grazing on water quality, yield or site productivity in Texas. This is the only instrumented watershed study in Texas or Louisiana that is currently evaluating...

Hunter, T. K.; Blackburn, W. H.; Weichert, A. T.; Dobrowolski, J. P.

357

Development of a portable fuel-cetane-quality monitor. Interim report, Nov 86-Nov 90  

SciTech Connect (OSTI)

In a program sponsored by the U.S. Army Belvoir Research, Development and Engineering Center, researchers at Southwest Research Institute have been developing a new procedure for rating the ignition quality of fuels for diesel engines. The ultimate goal is to develop a new scale (to replace the current cetane scale) and procedure. The preliminary goal, however, is to develop an apparatus and procedure to determine cetane number using ignition delay time as determined in a small constant-volume combustion bomb. The development activities have involved experiments designed to determine the relationship between the various experimental variables, experiments designed to assess the quality of the cetane determinations, and development activities designed to improve or refine the calibration and test procedures. This report is a summary of the findings of these experiments and a discussion of the validity of the techniques for cetane determination.

Ryan, T.W.

1992-05-01T23:59:59.000Z

358

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the Marine Sciences Laboratory, Sequim Site  

SciTech Connect (OSTI)

This document of Data Quality Objectives (DQOs) was prepared based on the U.S. Environmental Protection Agency (EPA) Guidance on Systematic Planning Using the Data Quality Objectives Process, EPA, QA/G4, 2/2006 (EPA 2006), as well as several other published DQOs. The intent of this report is to determine the necessary steps required to ensure that radioactive emissions to the air from the Marine Sciences Laboratory (MSL) headquartered at the Pacific Northwest National Laboratory’s Sequim Marine Research Operations (Sequim Site) on Washington State’s Olympic Peninsula are managed in accordance with regulatory requirements and best practices. The Sequim Site was transitioned in October 2012 from private operation under Battelle Memorial Institute to an exclusive use contract with the U.S. Department of Energy, Office of Science, Pacific Northwest Site Office.

Barnett, J. M.; Meier, Kirsten M.; Snyder, Sandra F.; Antonio, Ernest J.; Fritz, Brad G.; Poston, Theodore M.

2012-12-27T23:59:59.000Z

359

Sewage sludge application effects on runoff water quality in a semiarid grassland  

SciTech Connect (OSTI)

One of the concerns of land application of sewage sludge (also referred to as biosolids) to rangeland is its effect on the amount and quality of runoff water. In this study, we applied three treatments consisting of 0, 22, and 41 Mg ha{sup -1} of municipal sewage sludge to Larim gravelly sandy loam (Ustollic Argiustoll) and Altvan sandy loam (Aridic Argiustoll) soils in paired plots on two slope gradients (8 and 15%). We used a one-time application of simulated rainfall for 30 min at a rate of 100 mm h{sup -1} and collected and analyzed the runoff. Results are described. 22 refs., 1 fig., 5 tabs.

Harris-Pierce, R.L.; Redente, E.F.; Barbarick, K.A. [Colorado State Univ., Fort Collins, CO (United States)

1995-01-01T23:59:59.000Z

360

RCRA (Resource Conservation and Recovery Act) ground-water monitoring projects for Hanford facilities: Annual Progress Report for 1989  

SciTech Connect (OSTI)

This report describes the progress during 1989 of 16 Hanford Site ground-water monitoring projects covering 25 hazardous waste facilities and 1 nonhazardous waste facility. Each of the projects is being conducted according to federal regulations based on the Resource Conservation and Recovery Act of 1976 and the State of Washington Administrative Code. 40 refs., 75 figs., 6 tabs.

Smith, R.M.; Gorst, W.R. (eds.)

1990-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Tracking Non-point Fecal Pollution in the Guadalupe River: Distinguishing Urban and Rural Influences upon Water Quality  

E-Print Network [OSTI]

, Assistant Professor University of Houston - Victoria Non-point fecal pollution is a problem in water bodiesTracking Non-point Fecal Pollution in the Guadalupe River: Distinguishing Urban and Rural Influences upon Water Quality Matthew Boyett University of Houston - Victoria boyettmr@uhv.edu Dmitri Sobolev

362

Small Drains, Big Problems: The Impact of Dry Weather Runoff on Shoreline Water Quality at Enclosed Beaches  

E-Print Network [OSTI]

. In this paper we present field measurements and modeling studies aimed at evaluating the impact of small storm is minimal and human contact likely. Outdoor water conservation and urban retrofits that minimize the volume beach water quality in Newport Bay and other urban-impacted enclosed beaches. INTRODUCTION Enclosed

AghaKouchak, Amir

363

A modeling approach to evaluate the impacts of water quality management plans implemented in a watershed in Texas  

E-Print Network [OSTI]

best management practices (BMPs) have been implemented through Water Quality Management Plans (WQMPs; Best management practices Software availability Name of the software: Soil and Water Assessment Tool. doi:10.1016/j.envsoft.2005.05.013 www.elsevier.com/locate/envsoft Environmental Modelling & Software

364

A new technique to monitor ground-water quality at municipal solid waste landfills  

E-Print Network [OSTI]

government substantially increased its role in managing solid waste when Congress passed the Resource Conservation and Recovery Act (RCRA, 1976). Subtitle D of this act requires the Federal government to establish guidelines and provide technical... assistance to the States for the planning and developing of nonhazardous solid waste management programs. Under authority of Sections 1003(a)(3) and 40D4(a) of RCRA, the EPA issued the "Criteria for Classification of Solid Maste Disposal Facilities...

Hart, Steven Charles

1989-01-01T23:59:59.000Z

365

Water Quality Monitoring in the Buck Creek Watershed and Facilitation of Buck Creek Watershed Partnership  

E-Print Network [OSTI]

around well-publicized events in the watershed including the two watershed partnership meetings and the announcement of the Texas Environmental Excellence Award winners. www.buckcreek.tamu.edu Educational Programming Providing educational...

Gregory, L.; Dyer, P.

366

Raft River monitor well potentiometric head responses and water quality as  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to: navigation, search RAPIDColoradosource HistoryRaft River Sector Geothermal

367

Water quality criteria for colored smokes: Solvent Green 3: Final report  

SciTech Connect (OSTI)

The available data on the environmental fate, aquatic toxicity, and mammalian toxicity of Solvent Green 3, an anthraquinone dye used in colored smoke grenades, were reviewed. The US Environmental Protection Agency (USEPA) guidelines were used in an attempt to generate water quality criteria for the protection of human health and of aquatic life and its uses. Sufficient data to determine the toxicity of Solvent Green 3 in freshwater aquatic organisms are lacking. The 96-hr TL/sub 50/ for Pimephales promelas is >100 mg/L. Solvent Green 3, at a concentration of 10 mg/L, causes a transient reduction in growth of the green alga Selenastrum capricornutum. No data are available concerning the chronic toxicity or bioaccumulation of Solvent Green 3 in aquatic organisms. No data are available on any of the toxicity parameters for Solvent Green 3 in humans. No data on the pharmacokinetics of Solvent Green 3 administered orally in laboratory animals are available. Solvent Green 3 has a low order of toxicity whether administered by the oral, dermal, or inhalation route. The acute oral LD/sub 50/ is >3.16 g/kg in rats, but may be as high as 15 g/kg, >1 g/kg in dogs, and 10 g/kg in rabbits. Sufficient pertinent data were not available for deriving a water quality criterion for the protection of human health. 83 refs., 3 figs., 10 tabs.

Davidson, K.A.; Hovatter, P.S.

1987-12-01T23:59:59.000Z

368

West Village Community: Quality Management Processes and Preliminary Heat Pump Water Heater Performance  

SciTech Connect (OSTI)

West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. The project when complete will provide housing for students, faculty, and staff with a vision to minimize the community's impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

Dakin, B.; Backman, C.; Hoeschele, M.; German, A.

2012-11-01T23:59:59.000Z

369

Chemical trends at lakes ans streams in the UK Acid Waters Monitoring Network, 19882000 Hydrology and Earth System Sciences, 5(3), 351366 (2001) EGS  

E-Print Network [OSTI]

of `acid rain' were first documented in the Pennines, Northern England, following the onsetChemical trends at lakes ans streams in the UK Acid Waters Monitoring Network, 1988­2000 351 in the UK Acid Waters Monitoring Network, 1988-2000: Evidence for recent recovery at a national scale C

Paris-Sud XI, Université de

370

Groundwater Protection Program Calendar Year 1998 Evaluation of Groundwater and Surface Water Quality Data for the Bear Creek Hydrogeologic Regime at the U.S. Department of Energy Y-12 Plant, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

This report presents an evaluation of the water quality monitoring data obtained by the Y-12 Plant Groundwater Protection Program (GWPP) in the Bear Creek Hydrogeologic Regime (Bear Creek Regime) during calendar year (CY) 1998. The Bear Creek Regime contains many confirmed and potential sources of groundwater and surface water contamination associated with the U.S. Department of Energy (DOE) Oak Ridge Y-12 Plant. Applicable provisions of DOE Order 5400.1A - General Environmental Protection Program - require evaluation of groundwater and surface water quality near the Y-12 Plant to: (1) gauge groundwater quality in areas that are, or could be, affected by plant operations, (2) determine the quality of surface water and groundwater where contaminants are most likely to migrate beyond the DOE Oak Ridge Reservation (ORR) property line, and (3) identify and characterize long-term trends in groundwater quality. The following sections of this report contain relevant background information (Section 2.0); describe the results of the respective data evaluations required under DOE Order 5400.1A (Section 3.0); summarize significant findings of each evaluation (Section 4.0); and list the technical reports and regulatory documents cited for more detailed information (Section 5.0). All of the figures (maps and trend graphs) and data tables referenced in each section are presented in Appendix A and Appendix B, respectively.

None

1999-09-01T23:59:59.000Z

371

COLLINS, KELLY ALYSSA. A Field Evaluation of Four Types of Permeable Pavement with Respect to Water Quality Improvement and Flood Control. (Under the direction of  

E-Print Network [OSTI]

to Water Quality Improvement and Flood Control. (Under the direction of Dr.William F. Hunt.) In North were compared to permeable pavement exfiltrate quality for pH and concentrations of total nitrogen (TN capabilities in reducing runoff, but are not credited for improving water quality. To further test

Hunt, William F.

372

Twelve Months of Air Quality Monitoring at Ash Meadows National Wildlife Refuge, Southwestern Rural Nevada, U.S.A (EMSI April 2007)  

SciTech Connect (OSTI)

The one year of air quality monitoring data collected at the Ash Meadows National Wildlife Refuge (NWR) was the final part of the air quality "Scoping Studies" for the Environmental Monitoring Systems Initiative (EMSI) in southern and central Nevada. The objective of monitoring at Ash Meadows was to examine aerosol and meteorological data, seasonal trends in aerosol and meteorological parameters as well as to examine evidence for long distance transport of some constituents. The 9,307 hectare refuge supports more than 50 springs and 24 endemic species, including the only population of the federally listed endangered Devil’s Hole pupfish (Cyprinodon diabolis) (U.S. Fish and Wildlife Service, 1990). Ash Meadows NWR is located in a Class II air quality area, and the aerosol measurements collected with this study are compared to those of Interagency Monitoring of Protected Visual Environments (IMPROVE) sites. Measurements taken at Ash Meadows NWR over a period of 12 months provide new baseline air quality and meteorological information for rural southwestern Nevada, specifically Nye County and the Amargosa Valley.

Engelbrecht, Johann P; Shafer, David S; Campbell, Dave; Campbell, Scott; McCurdy, Greg; Kohl, Steven D; Nikolich, George; Sheetz, Larry

2011-08-01T23:59:59.000Z

373

Lake Whitney Comprehensive Water Quality Assessment, Phase 1B- Physical and Biological Assessment (USDOE)  

SciTech Connect (OSTI)

Baylor University Center for Reservoir and Aquatic Systems Research (CRASR) has conducted a phased, comprehensive evaluation of Lake Whitney to determine its suitability for use as a regional water supply reservoir. The area along the Interstate 35 corridor between Dallas / Fort Worth Metroplex and the Waco / Temple Centroplex represents one of the fastest growth areas in the State of Texas and reliable water supplies are critical to sustainable growth. Lake Whitney is situated midway between these two metropolitan areas. Currently, the City of Whitney as well as all of Bosque and Hill counties obtain their potable water from the Trinity Sands aquifer. Additionally, parts of the adjoining McLennan and Burleson counties utilize the Trinity sands aquifer system as a supplement to their surface water supplies. Population growth coupled with increasing demands on this aquifer system in both the Metroplex and Centroplex have resulted in a rapid depletion of groundwater in these rural areas. The Lake Whitney reservoir represents both a potentially local and regional solution for an area experiencing high levels of growth. Because of the large scope of this project as well as the local, regional and national implications, we have designed a multifaceted approach that will lead to the solution of numerous issues related to the feasibility of using Lake Whitney as a water resource to the region. Phase IA (USEPA, QAPP Study Elements 1-4) of this research focused on the physical limnology of the reservoir (bathymetry and fine scale salinity determination) and develops hydrodynamic watershed and reservoir models to evaluate how salinity would be expected to change with varying hydrologic and climatic factors. To this end, we implemented a basic water quality modeling program in collaboration with the Texas Parks and Wildlife Department and the Texas Commission on Environmental Quality to add to the developing long-term database on Lake Whitney. Finally, we conducted an initial assessment of knowledge of watershed and water quality related issues by local residents and stakeholders of Lake Whitney and design an intervention educational program to address any deficiencies discovered. Phase IA was funded primarily from EPA Cooperative Agreement X7-9769 8901-0. Phase IC (USEPA, QAPP Study Element 5) of this research focused on the ambient toxicity of the reservoir with respect to periodic blooms of golden algae. Phase IC was funded primarily from Cooperative Agreement EM-96638001. Phase 1B (USDOE, Study Elements 6-11) complemented work being done via EPA funding on study elements 1-5 and added five new study elements: 6) Salinity Transport in the Brazos Watershed to Lake Whitney; 7) Bacterial Assessment; 8) Organic Contaminant Analysis on Lake Whitney; 9) Plankton Photosynthesis; 10) Lake Whitney Resident Knowledge Assessment; and 11) Engineering Scoping Perspective: Recommendations for Use.

Doyle, Robert D; Byars, Bruce W

2009-11-24T23:59:59.000Z

374

Water quality criteria for colored smokes: 1,4-diamino-2,3-dihydroanthraquinone: Final report  

SciTech Connect (OSTI)

The available data on the environmental fate, aquatic toxicity, and mammalian toxicity of 1,4-diamino-2,3-dihydroanthraquinone (DDA), and anthraquinone dye used in violet-colored smoke grenades, were reviewed. The US Environmental Protection Agency (USEPA) guidelines were used in an attempt to generate water quality criteria for the protection of human health and of aquatic life and its uses. DDA will readily oxidize to 1,4-diaminoanthraquinone (DAA) in air or during combustion of the smoke grenade. The dye is insoluble in water; however, no information is available concerning its transformation or transport in soil, water, and sediments. No data are available concerning the toxic effects of DDA in aquatic organisms; therefore, a Criterion maximum Concentration and a Criterion Continuous Concentration cannot be determined. Toxicity studies following the USEPA guidelines are recommended. DDA is a weak mutagen in the Salmonella Reversin Assay, but the combustion or oxidation product, DAA is a strong mutagen in the same test. Violet smoke is noncarcinogenic in the SENCAR Mouse Skin Tumor Bioassay. 63 refs., 1 fig., 3 tabs.

Davidson, K.A.; Hovatter, P.S.; Ross, R.H.

1988-01-01T23:59:59.000Z

375

DOE/NV/26383-LTR2008-01 Letter Report Yucca Mountain Environmental Monitoring Systems Initiative - Air Quality Scoping Study for Caliente, Lincoln County, Nevada  

SciTech Connect (OSTI)

The Desert Research Institute (DRI) is performing a scoping study as part of the U.S. Department of Energy's Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at eight sites outside the NTS, including Ash Meadows National Wildlife Refuge (NWR), Beatty, Sarcobatus Flats, Rachel, Caliente, Pahranagat NWR, Crater Flat, and Tonopah Airport, and at four sites on the NTS (Engelbrecht et al., 2007a-d). The trailer is stationed at any one site for approximately eight weeks at a time. This letter report provides a summary of air quality and meteorological data, on completion of the site's sampling program.

J. Engelbrecht; I. Kavouras; D. Campbell; S. Campbell; S. Kohl; D. Shafer

2009-04-02T23:59:59.000Z

376

Assessing environmental impacts on stream water quality: deforestation in mid-Wales Hydrology and Earth System Sciences, 6(3), 421431 (2002) EGS  

E-Print Network [OSTI]

Assessing environmental impacts on stream water quality: deforestation in mid-Wales 421 Hydrology and Earth System Sciences, 6(3), 421­431 (2002) © EGS Assessing environmental impacts on stream water the environmental sciences, there are major management issues over the impact of man on the water quality

Boyer, Edmond

377

Studien-und Prfungsordnung der Universitt Stuttgart fr den auslandsorientierten Studiengang Air Quality Control, Solid Waste and Waste Water Process Engineering  

E-Print Network [OSTI]

Air Quality Control, Solid Waste and Waste Water Process Engineering (WASTE) mit Abschluss Master Quality Control, Solid Waste and Waste Water Process Engineering" (WASTE) beschlossen. Der Rektor hat Control, Solid Waste and Waste Water Process Engineering" (WASTE) überblickt werden, die Fähigkeit

Reyle, Uwe

378

The effects of an intermittent piped water network and storage practices on household water quality in Tamale, Ghana  

E-Print Network [OSTI]

The United Nations Millennium Development Goals include a target to halve the number of people without access to "improved" water sources, which include piped water supply. However, an "improved" source of water does not ...

Vacs Renwick, Deborah Alexandra

2013-01-01T23:59:59.000Z

379

Montana Ground Water Assessment Act (Montana)  

Broader source: Energy.gov [DOE]

This statute establishes a program to systematically assess and monitor the state's ground water and to disseminate the information to interested persons in order to improve the quality of ground...

380

Gadolinium-doped water cerenkov-based neutron and high energy gamma-ray detector and radiation portal monitoring system  

DOE Patents [OSTI]

A water Cerenkov-based neutron and high energy gamma ray detector and radiation portal monitoring system using water doped with a Gadolinium (Gd)-based compound as the Cerenkov radiator. An optically opaque enclosure is provided surrounding a detection chamber filled with the Cerenkov radiator, and photomultipliers are optically connected to the detect Cerenkov radiation generated by the Cerenkov radiator from incident high energy gamma rays or gamma rays induced by neutron capture on the Gd of incident neutrons from a fission source. The PMT signals are then used to determine time correlations indicative of neutron multiplicity events characteristic of a fission source.

Dazeley, Steven A; Svoboda, Robert C; Bernstein, Adam; Bowden, Nathaniel

2013-02-12T23:59:59.000Z

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

UV Disinfection Equipment Marketing Plan. "The Impact of New Water Quality Effluent Standards and Whole Body Contact Classification of Missouri Waters"  

E-Print Network [OSTI]

3 State of Missouri Regulatory Impact Report for Proposed Rule Amendment 10 CSR 20-7.03 Water Quality Standards, Missouri Department of Natural Resources, Water Protection and Soil Conservation Division, Water Protection Program, http://www.dnr.mo.gov/env..., USEPA, Region 7, letter from U.S. Environmental Protection Agency (USEPA) that approved and disapproved parts of Missouri?s WQS, U, Kansas City, Kansas, Sept. 8, 2000. http://www.dnr.mo.gov/env/wpp/rules/usepa_2000_letter-pgs1- 14.pdf, http://www.dnr.mo.gov/env...

Koehler, Paul

2006-05-19T23:59:59.000Z

382

Preliminary evaluation of VTA effectiveness to protect runoff water quality on small pork production facilities in Texas  

E-Print Network [OSTI]

/or Robertson County sites on the following dates: • January 9, 2013 • February 10, 2013 • March 10, 2013 • April 3, 2013 • May 9, 2013 • May 16, 2013 • May 21, 2013 • June 3, 2013 • June 10, 2013 • July 15, 2013 Results from the analysis... Research Service Texas Water Resources Institute TR-452 November 2013 Preliminary evaluation of VTA effectiveness to protect runoff water quality on small pork production facilities in Texas STATE NONPOINT SOURCE GRANT PROGRAM TSSWCB PROJECT...

Wagner, K.; Harmel, D.; Higgs, K.

2013-01-01T23:59:59.000Z

383

The Weather Is Our Water Supply:The Weather Is Our Water Supply: Community Involvement in Monitoring Climate  

E-Print Network [OSTI]

University Presented at New Mexico State University March 10, 2005, Las Cruces, NM. Prepared by Odie Bliss Climatologist and Senior Research Associate, nolan@atmos.colostate.edu Odie Bliss Coordinator, odie Monitoring Activities Fort Collins Historic Weather Station ­ Continuous observations from 1889 to present

384

Changing the spatial location of electricity generation to increase water availability in areas with drought: a feasibility study and quantification of air quality impacts in Texas  

E-Print Network [OSTI]

The feasibility, cost, and air quality impacts of using electrical grids to shift water use from drought-stricken regions to areas with more water availability were examined. Power plant cooling represents a large portion ...

Pacsi, Adam P

385

Division of Water, Parts 700-750 and Parts 800-941: Classes and Standards of Quality and Purity (New York)  

Broader source: Energy.gov [DOE]

These sections describe general standards of water quality and purity as well as standards for specific water bodies (Parts 800-941). The regulations provide classifications for different types of...

386

Water Heaters and Hot Water Distribution Systems  

E-Print Network [OSTI]

24 Figure 7. Comparison of Daily Water Heater28 Figure 8. Monitored Field Efficiency of Tankless Water28 Figure 9. Monitored Lab Efficiency of Tankless Water

Lutz, Jim

2012-01-01T23:59:59.000Z

387

Communication Pathways in the Light Water Reactor Sustainability Online Monitoring Project  

SciTech Connect (OSTI)

Implementation of online monitoring and prognostics in existing U.S. nuclear power plants will involve coordinating the efforts of national laboratories, utilities, universities, and private companies. Large amounts of operational data, including failure data, are necessary for the development and calibration of diagnostic and prognostic algorithms. The ability to use data from all available resources will provide the most expeditious avenue to implementation of online monitoring in existing NPPs; however, operational plant data are often considered proprietary. Secure methods for transferring and storing data are discussed, along with a potential technology for implementation of online monitoring.

Nancy J. Lybeck; Magdy S. Tawfik; Binh T. Pham; Vivek Agarwal; Jamie Coble

2011-09-01T23:59:59.000Z

388

Remote Sensing of Soil and Water Quality in Agroecosystems Vincent de Paul Obade & Rattan Lal & Jiquan Chen  

E-Print Network [OSTI]

and reflection radiometer ASD Analytical spectral device AVIRIS Airborne visible/infrared imaging spectrometer near real-time information on soil and water quality in the context of major land use practices SPOT Satellites pour l'observation de la terre or earth-observing satellites SWIR Short-wave infrared

Chen, Jiquan

389

organized in cooperation with TU Vienna, (Institute for Water Quality, Resource and Waste Management) Analysis, Evaluation and Design of  

E-Print Network [OSTI]

organized in cooperation with TU Vienna, (Institute for Water Quality, Resource and Waste Management) Analysis, Evaluation and Design of Sustainable Waste Management Systems Goal The objective of the ISWA-TU Vienna Summer School (iTOOL) is to provide advanced knowledge in the field of waste management

Szmolyan, Peter

390

Twenty-Plus Years of Environmental Change and Ecological Recovery of East Fork Poplar Creek: Background and Trends in Water Quality  

SciTech Connect (OSTI)

In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Department of Energy's Y-12 National Security Complex (Y-12 Complex) in Oak Ridge, Tennessee, USA, allowing discharge of effluents to East Fork Poplar Creek (EFPC). The effluents ranged from large volumes of chlorinated once-through cooling water and cooling tower blow-down to smaller discharges of treated and untreated process wastewaters, which contained a mixture of heavy metals, organics, and nutrients, especially nitrates. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to meet two major objectives: demonstrate that the established effluent limitations were protecting the classified uses of EFPC, and document the ecological effects resulting from implementing a Water Pollution Control Program at the Y-12 Complex. The second objective is the primary focus of the other papers in this special series. This paper provides a history of pollution and the remedial actions that were implemented; describes the geographic setting of the study area; and characterizes the physicochemical attributes of the sampling sites, including changes in stream flow and temperature that occurred during implementation of the BMAP. Most of the actions taken under the Water Pollution Control Program were completed between 1986 and 1998, with as many as four years elapsing between some of the most significant actions. The Water Pollution Control Program included constructing nine new wastewater treatment facilities and implementation of several other pollution-reducing measures, such as a best management practices plan; area-source pollution control management; and various spill-prevention projects. Many of the major actions had readily discernable effects on the chemical and physical conditions of EFPC. As controls on effluents entering the stream were implemented, pollutant concentrations generally declined and, at least initially, the volume of water discharged from the Y-12 Complex declined. This reduction in discharge was of ecological concern and led to implementation of a flow management program for EFPC. Implementing flow management, in turn, led to substantial changes in chemical and physical conditions of the stream: stream discharge nearly doubled and stream temperatures decreased, becoming more similar to those in reference streams. While water quality clearly improved, meeting water quality standards alone does not guarantee protection of a waterbody's biological integrity. Results from studies on the ecological changes stemming from pollution-reduction actions, such as those presented in this series, also are needed to understand how best to restore or protect biological integrity and enhance ecological recovery in stream ecosystems. With a better knowledge of the ecological consequences of their decisions, environmental managers can better evaluate alternative actions and more accurately predict their effects.

Smith, John G [ORNL; Stewart, Arthur J [ORNL; Loar, James M [ORNL

2011-01-01T23:59:59.000Z

391

Air/water subchannel measurements of the equilibrium quality and mass-flux distribution in a rod bundle. [BWR  

SciTech Connect (OSTI)

Subchannel measurements were performed in order to determine the equilibrium quality and mass flux distribution in a four rod bundle, using air/water flow. An isokinetic technique was used to sample the flow in the center, side and corner subchannels of this test section. Flow rates of the air and water in each sampled subchannel were measured. Experiments were performed for two test-section-average mass fluxes (0.333x10/sup 6/ and 0.666x10/sup 6/ lb/sub m//h-ft/sup 2/), and the test-section-average quality was varied from 0% to 0.54% for each mass flux. Single-phase liquid, bubbly, slug and churn-turbulent two-phase flow regimes were achieved. The observed data trends agreed with previous diabatic measurements in which the center subchannel had the highest quality and mass flux, while the corner subchannel had the lowest.

Sterner, R.W.; Lahey, R.T. Jr.

1983-07-01T23:59:59.000Z

392

A new approach to power quality and electricity reliability monitoring-case study illustrations of the capabilities of the I-GridTM system  

SciTech Connect (OSTI)

This report describes a new approach for collecting information on power quality and reliability and making it available in the public domain. Making this information readily available in a form that is meaningful to electricity consumers is necessary for enabling more informed private and public decisions regarding electricity reliability. The system dramatically reduces the cost (and expertise) needed for customers to obtain information on the most significant power quality events, called voltage sags and interruptions. The system also offers widespread access to information on power quality collected from multiple sites and the potential for capturing information on the impacts of power quality problems, together enabling a wide variety of analysis and benchmarking to improve system reliability. Six case studies demonstrate selected functionality and capabilities of the system, including: Linking measured power quality events to process interruption and downtime; Demonstrating the ability to correlate events recorded by multiple monitors to narrow and confirm the causes of power quality events; and Benchmarking power quality and reliability on a firm and regional basis.

Divan, Deepak; Brumsickle, William; Eto, Joseph

2003-04-01T23:59:59.000Z

393

Monitoring and evaluation of a ceramic water filter and hand-washing intervention in Northern Ghana  

E-Print Network [OSTI]

Through a Rotary Club contract, PHW will sell Kosim filters and install Tippy-Tap hand-washing stations in 1250 households in Northern Ghana. This thesis presents the following project monitoring and evaluation components: ...

Lu, Connie C

2012-01-01T23:59:59.000Z

394

Monitoring effective use of household water treatment and safe storage technologies in Ethiopia and Ghana  

E-Print Network [OSTI]

Household water treatment and storage (HWTS) technologies dissemination is beginning to scale-up to reach the almost 900 million people without access to an improved water supply (WHO/UNICEF/JMP, 2008). Without well-informed ...

Stevenson, Matthew M

2009-01-01T23:59:59.000Z

395

Effect of drought and fires on the quality of water in Lithuanian rivers Hydrology and Earth System Sciences, 7(3), 423427 (2003) EGU  

E-Print Network [OSTI]

to the surface water. Keywords: heavy metals, river water quality, Lithuania Introduction Increasingly, negative of secondary heavy metal pollution (Crossland and LaPoint, 1992). These processes may make water bodies unsuitable for human consumption and toxic to organisms living in the water. Heavy metals are harmful

Boyer, Edmond

396

Sanitary Landfill Groundwater Monitoring Report - Fourth Quarter 1998 and 1998 Summary  

SciTech Connect (OSTI)

A maximum of fifty-three wells of the LFW series monitor groundwater quality in the Steed Pond Aquifer (Water Table) beneath the Sanitary Landfill at the Savannah River Site (SRS). These wells are sampled quarterly to comply with the South Carolina Department of Health and Environmental Control Domestic Water permit and as part of the SRS Groundwater Monitoring Program.

Chase, J.

1999-04-09T23:59:59.000Z

397

ICDP Complex Groundwater Monitoring Plan REV 5  

SciTech Connect (OSTI)

This Groundwater Monitoring Plan, along with the Quality Assurance Project Plan for Waste Area Groups 1, 2, 3, 4, 5, 6, 7, 10, and Removal Actions, constitutes the sampling and analysis plan for groundwater and perched water monitoring at the Idaho CERCLA Disposal Facility (ICDF). A detection monitoring system was installed in the Snake River Plan Aquifer to comply with substantive requirements of "Releases from Solid Waste Management Units" of the Resource Conservation and Recovery Act. This detection monitoring wells constructed in the Snake River Plain Aquifer.

Cahn, L. S.

2007-08-09T23:59:59.000Z

398

Acoustic Emission and Guided Ultrasonic Waves for Detection and Continuous Monitoring of Cracks in Light Water Reactor Components  

SciTech Connect (OSTI)

Acoustic emission (AE) and guided ultrasonic waves (GUW) are considered for continuous monitoring and detection of cracks in Light Water Reactor (LWR) components. In this effort, both techniques are applied to the detection and monitoring of fatigue crack growth in a full scale pipe component. AE results indicated crack initiation and rapid growth in the pipe, and significant GUW responses were observed in response to the growth of the fatigue crack. After initiation, the crack growth was detectable with AE for approximately 20,000 cycles. Signals associated with initiation and rapid growth where distinguished based on total rate of activity and differences observed in the centroid frequency of hits. An intermediate stage between initiation and rapid growth was associated with significant energy emissions, though few hits. GUW exhibit a nearly monotonic trend with crack length with an exception of measurements obtained at 41 mm and 46 mm.

Meyer, Ryan M.; Coble, Jamie B.; Ramuhalli, Pradeep; Watson, Bruce E.; Cumblidge, Stephen E.; Doctor, Steven R.; Bond, Leonard J.

2012-06-28T23:59:59.000Z

399

Water Quality Co-effects of Greenhouse Gas Mitigation in US Agriculture Subhrendu K. Pattanayak, Bruce A. McCarl, Allan J. Sommer, Brian C. Murray, Timothy  

E-Print Network [OSTI]

greenhouse gas (GHG) emission offset strategies in U.S. agriculture by linking a national level agriculturalWater Quality Co-effects of Greenhouse Gas Mitigation in US Agriculture Subhrendu K. Pattanayak sector model (ASMGHG) to a national level water quality model (NWPCAM). The simulated policy scenario

McCarl, Bruce A.

400

Environmental Quality: Air (Louisiana)  

Broader source: Energy.gov [DOE]

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Impacts of motor vehicle operation on water quality - Clean-up Costs and Policies  

E-Print Network [OSTI]

Contribution of heavy metals to storm water from automotiveheavy metals can make highway runoff chronically toxic to receiving waters.heavy metals (such as Pb, Zn, or Cu) or hydrocarbon loadings of surface water

Nixon, Hilary; Saphores, Jean-Daniel M

2007-01-01T23:59:59.000Z

402

Modeling Urban Storm-Water Quality Treatment: Model Development and Application to a Surface Sand Filter  

E-Print Network [OSTI]

water impacts has led us to the develop- ment of different storm-water treatment strategies. Previous knowledge regarding traditional water treatment systems drink- ing and wastewater and the evaluation

403

Design and installation of continuous flow and water quality monitoring stations to improve water quality forecasting in the lower San Joaquin River  

E-Print Network [OSTI]

¼ mile south of Hwy 140. Solar Panel with 12-volt batteryMarshall Road Reservoir. Solar Panel with 12-volt batteryflows from adjacent fields. Solar Panel with 12-volt battery

Quinn, Nigel W.T.

2007-01-01T23:59:59.000Z

404

CEMS (continuous emission monitoring systems) pilot project: evaluation of opacity CEMS reliability and QA (quality assurance) procedures. Volume 1  

SciTech Connect (OSTI)

A study was conducted in Missouri to evaluate the reliability of opacity-monitoring data and to facilitate the development and evaluation of QA procedures for opacity CEMS's. The study included opacity CEMS's installed on six coal-fired electric utility generating units at four generating stations, each owned by a different company. The sources were representative of a wide range of monitoring applications and conditions, and were equipped with contemporary opacity monitoring instrumentation. For each station, monitor- and source-specific opacity CEMS QA procedures were developed and CEMS audits were conducted at the beginning of the study. Plant personnel implemented and revised the QA procedures and conducted a performance audit during a 6- to 8-month period. Performance audits were also conducted at the end of the study. The report presents evaluations both of opacity CEMS reliability (i.e., accuracy, precision, and availability) and of the QA procedures that were used in the study. In summary, appropriate and effective QA procedures can be developed and implemented for a variety of opacity monitoring equipment and applications without imposing an undue burden on the monitor operators. Such procedures are inherently source- and monitor-specific. Reliable opacity monitoring data are obtained when appropriate QA procedures are implemented.

Peeler, J.W.

1986-05-01T23:59:59.000Z

405

The mineral content of water as a variable in the quality control of reconstituted non-fat dry milk products  

E-Print Network [OSTI]

LibK?ARr '< A 4 M CuLLEftE ?F TEXAf. THE MINERAL CONTENT OF WATER AS A VARIABLE IN THE QUALITY CONTROL OF RECONSTITUTED NONFAT DRY MILK PRODUCTS By JOHN 0. KAPSAUS A Dissertation Submitted to the Graduate School of the Agricultural...). This is the CO2 evolved in the milk, which has been reconstituted with the respective level of bicarbonate water, in the uninoculated tube. (E) CO2 produced from the action of the apparent milk acidity on the bicarbonate. This is the CO2 calculated from...

Kapsalis, John G.

2013-10-04T23:59:59.000Z

406

Environmental monitoring plan - environmental monitoring section. Revision 1  

SciTech Connect (OSTI)

This report presents the environmental monitoring plan for the Lawrence Livermore National Laboratory. A site characterization is provided along with monitoring and measurement techniques and quality assurance measures.

Wilt, G.C. [ed.; Tate, P.J.; Brigdon, S.L. [and others

1994-11-01T23:59:59.000Z

407

Water Distribution System Monitoring and Decision Support Using a Wireless Sensor Network  

E-Print Network [OSTI]

Water distribution systems comprise labyrinthine networks of pipes, often in poor states of repair, that are buried beneath our city streets and relatively inaccessible. Engineers who manage these systems need reliable ...

Allen, Michael

408

A water quality assessment of the import of turfgrass sod grown with composted dairy manure into a suburban watershed  

E-Print Network [OSTI]

) have caused water quality concerns in many rural watersheds, sometimes forcing the State of Texas to conduct Total Maximum Daily Load (TMDL) assessments of stream nutrients such as nitrogen (N) and phosphorus (P). One suggested Best Management... Practice (BMP) is the export of phosphorus (P) through turfgrass sod produced with composted dairy manure from an impaired rural watershed to an urban watershed. The manure-grown sod releases P slowly and would not require additional P fertilizer for up...

Richards, Chad Edward

2005-02-17T23:59:59.000Z

409

Risk perception, drinking water source and quality in a low-income Latino community along the U.S.-Mexico Border.  

E-Print Network [OSTI]

1 Risk perception, drinking water source and quality in a low-income Latino community along the U Dental Association (ADA) is concerned that individuals who primarily drink bottled water may, elucidated why Latinos perceive tap water to be unsafe for drinking, and identified whether individuals have

Fay, Noah

410

Data Visualization for Quality-Check Purposes of Monitored Electricity Consumption in All Office Buildings in the ESL Database  

E-Print Network [OSTI]

This report comprises an effort to visualize the monitored electricity consumption in all office buildings (not including the office buildings comprising other functions as classrooms and laboratories, for instance) in the ESL database. This data...

Sreshthaputra, A.; Abushakra, B.; Haberl, J. S.; Claridge, D. E.

2000-01-01T23:59:59.000Z

411

Bacterial Monitoring for the Buck Creek Watershed  

E-Print Network [OSTI]

The “Bacterial Monitoring for the Buck Creek Watershed” project was developed in response to the creek’s listing on the Texas Water Quality Inventory and 303(d) List due to a bacterial impairment and subsequent total maximum daily load (TMDL...

412

CHAPTER 6: WATER QUALITY 1998 SITE ENVIRONMENTAL REPORT6-1  

E-Print Network [OSTI]

facilities at Brookhaven National Laboratory (BNL) discharge or have the potential to dis- charge radioactive Real Time Monitor for Radioactivity pH, Conductivity, Oil (S5) Blower Building Abandoned Sand Filter

413

5-1 2002 SITE ENVIRONMENTAL REPORT CHAPTER 5: WATER QUALITY  

E-Print Network [OSTI]

, or inorganic contaminants. Monitoring, pollution prevention, and careful operation of treatment facilities for Radioactivity pH, Conductivity Blower Building Abandoned Sand Filter Beds Emergency Holding Ponds (lined) Pump

Homes, Christopher C.

414

Preventing Water Quality Contamination through the Texas Well Owners Network (TWON): Final Report  

E-Print Network [OSTI]

the Tex*A*Syst materials, additional TWON Fact Sheets were developed: ? Hydraulic Fracturing and Your Private Water Well (ESC-012) ? Protect Your Water Well During Drought (ESC-014) A TWON curriculum, including a handbook for participants...

Boellstorff, D.; Gholson, D.; Kalisek, D.; Smith, J.; Gerlich, R.; Wagner, K.; McFarland, M.; Mukhtar, S.

2014-01-01T23:59:59.000Z

415

Trading pollution for water quality : assessing the effects of market-based instruments in three basins  

E-Print Network [OSTI]

Since its passage in 1972, the majority of pollution reduction under the federal Clean Water Act has resulted from technology-based limits imposed on point source dischargers. However, most U.S. water bodies are unmonitored ...

Wallace, Katherine Hay

2007-01-01T23:59:59.000Z

416

Ceramic filter manufacturing in Northern Ghana : water storage and quality control  

E-Print Network [OSTI]

In 2009, Pure Home Water (PHW), a Ghana based non-profit organization working to provide affordable and safe drinking water to people in the Northern Region of Ghana, began the construction of a ceramic pot filter (CPF) ...

Kleiman, Shanti Lisa

2011-01-01T23:59:59.000Z

417

Legacy of historic mining and water quality in a heavily mined Scottish river catchment   

E-Print Network [OSTI]

Mine abandonment and the discharge of contaminated mine water is recognised globally as a major source of surface water and groundwater pollution. Contamination generally arises from the oxidation of sulphide minerals, ...

Haunch, Simon

2013-11-28T23:59:59.000Z

418

Feasibility Study of the Effects of Water Quality on Soil Properties in the Red River Valley  

E-Print Network [OSTI]

on permeability of soil to water. The effects of specific ions such as Na or lack of salts in the water can reduce permeability to the extent that crops are not adequately supplied with water and yields are reduced. As pointed out by Rhoades and Ingvalson...

Gerard, C. J.; Hipp, B. W.; Runkles, J. R.; Bordovsky, D. J.; McCully, W. G.

419

The Project The Southern Region Water Quality Regional Coordination Project is designed to promote regional collaboration,  

E-Print Network [OSTI]

issues: · Drinking Water and Human Health · Environmental Restoration · Waste Management · Nutrient to protect and restore water resources. Effective approaches for watershed management, pollution prevention and Pesticide Management · Pollution Assessment and Prevention · Watershed Management · Water Quantity

420

Water Quality Improvements: How do we know if we're doing  

E-Print Network [OSTI]

buffer grassland 250 m buffer Targeted Wetland crop to switchgrassPresettlement Conservation Tillage We or irritation Value of avoided water treatment Value of commercial fishing Fish abundance and productivity, illness or irritation Value of avoided water treatment #12;Trout angling Nitrogen Water clarity/ Algal

Farritor, Shane

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Advanced Metering Plan for Monitoring Energy and Potable Water Use in PNNL EMS4 Buildings  

SciTech Connect (OSTI)

This updated Advanced Metering Plan for monitoring whole building energy use in Pacific Northwest National Laboratory (PNNL) EMS4 buildings on the PNNL campus has been prepared in accordance with the requirements of the Energy Policy Act of 2005 (EPAct 2005), Section 103, U.S. Department of Energy (DOE) Order 430.2B, and Metering Best Practices, A Guide to Achieving Utility Resource Efficiency, Federal Energy Management Program, October 2007 (Sullivan et al. 2007). The initial PNNL plan was developed in July 2007 (Olson 2007), updated in September 2008 (Olson et al. 2008), updated in September 2009 (Olson et al. 2009), and updated again in August 2010 (Olson et al. 2010).

Pope, Jason E.; Olson, Norman J.; Berman, Marc J.; Schielke, Dale R.

2011-08-17T23:59:59.000Z

422

MONITORING PRESENT DAY CHANGES IN WATER VAPOUR AND THE RADIATIVE ENERGY BALANCE USING SATELLITE DATA,  

E-Print Network [OSTI]

precipitation events are expected to exert an adverse effect on agriculture, water resources, human health in the total area affected by drought and the flood risk associated with increased frequency of heavy of droughts. While there is evidence for this response (e.g. Neelin et al., 2006; Seager et al. 2007

Allan, Richard P.

423

Effects of Biochar Recycling on Switchgrass Growth and Soil and Water Quality in Bioenergy Production Systems  

E-Print Network [OSTI]

Intensive biomass production in emerging bioenergy systems could increase nonpoint-source sediment and nutrient losses and impair surface and groundwater quality. Recycling biochar, a charcoal byproduct from pyrolysis of biomass, provides potential...

Husmoen, Derek Howard

2012-07-16T23:59:59.000Z

424

Dedicated to Sharing Information About Water Management and the Florida LAKEWATCH Program Volume 61 (2013) LAKEWATCH Welcomes New Director Mark Hoyer  

E-Print Network [OSTI]

1 Dedicated to Sharing Information About Water Management and the Florida LAKEWATCH Program monitoring programs. Since 1986, reliable long-term water quality data have been to lakes management activities. Professionally, Mark is an active member

Florida, University of

425

Detection limits for real-time source water monitoring using indigenous freshwater microalgae  

SciTech Connect (OSTI)

This research identified toxin detection limits using the variable fluorescence of naturally occurring microalgae in source drinking water for five chemical toxins with different molecular structures and modes of toxicity. The five chemicals investigated were atrazine, Diuron, paraquat, methyl parathion, and potassium cyanide. Absolute threshold sensitivities of the algae for detection of the toxins in unmodified source drinking water were measured. Differential kinetics between the rate of action of the toxins and natural changes in algal physiology, such as diurnal photoinhibition, are significant enough that effects of the toxin can be detected and distinguished from the natural variance. This is true even for physiologically impaired algae where diminished photosynthetic capacity may arise from uncontrollable external factors such as nutrient starvation. Photoinhibition induced by high levels of solar radiation is a predictable and reversible phenomenon that can be dealt with using a period of dark adaption of 30 minutes or more.

Rodriguez Jr, Miguel [ORNL; Greenbaum, Elias [ORNL

2009-01-01T23:59:59.000Z

426

Trading pollution for water quality : assessing the effects of market-based instruments in three basins .  

E-Print Network [OSTI]

??Since its passage in 1972, the majority of pollution reduction under the federal Clean Water Act has resulted from technology-based limits imposed on point source… (more)

Wallace, Katherine Hay

2007-01-01T23:59:59.000Z

427

The impact of Texas water quality laws on dairy firm profitability and survival  

E-Print Network [OSTI]

Francis Schmucker, B. A. , Texas Tech University Chair of Advisory Committee: Dr. David J. Leatham Dairy waste management is one of the most important issues faced by Texas dairy producers. The Texas Water Commission regulations state there shall... be no discharge of waste and/or waste water into the waters of the State of Texas. The regulations also require a dairy having 250 or more milking cows to have a Texas Water Commission permit to operate. Dairy managers should therefore determine the least...

Schmucker, John Francis

1990-01-01T23:59:59.000Z

428

Grantee Checklist for the Inspection & Monitoring Requirement  

Broader source: Energy.gov [DOE]

This document walks Grantees through the Inspection & Monitoring requirement of the Quality Work Plan.

429

Water Quality Improvement Policies: Lessons Learned from the Implementation of Proposition O in Los Angeles, California  

E-Print Network [OSTI]

environmental strategies, management policies, and programs in response to increasingly stringent waterenvironmental nonpro?t applicants Selected experts working on storm-water managementEnvironmental Management (2009) 43:514–522 DOI 10.1007/s00267-008-9262-8 ENVIRONMENTAL ASSESSMENT Water

Park, Mi-Hyun; Stenstrom, Michael; Pincetl, Stephanie

2009-01-01T23:59:59.000Z

430

Treatment of drinking water to improve its sanitary or bacteriological quality is  

E-Print Network [OSTI]

,000 gallons), such an approach can be wasteful, increasing energy costs for the well pump to refill the tank Chlorine Amounts To sanitize water properly, enough chlorine needs to be added to a storage tank to reach bacteria have been properly destroyed by the sanitation process, submit water samples from a faucet served

431

Global impacts of conversions from natural to agricultural ecosystems on water resources: Quantity versus quality  

E-Print Network [OSTI]

for $90% of global freshwater consumption. Irrigation based on surface water reduced streamflow and raised is a critical issue because 1.1 billion of the world's 6 billion people lack access to safe drinking water [World Health Organization, 2003]. Agricultural food pro- duction accounted for an average of $90

Scanlon, Bridget R.

432

Application Study of the Pump Water Flow Station for Building Energy Consumption Monitoring and Control Optimization  

E-Print Network [OSTI]

. For example, the Venturi meter is commonly used for steam flow measurement, but it is less commonly used for water flow measurement because of the poor accuracy at low flow rates and high installation cost. 2) Displacement flow meter: The meter works... by using the fluid to rotate or displace a device inserted into the flow stream, e.g., a turbine flow meter, tangential paddlewheel meter, etc. It causes extra pressure drop. The bearing wears out and calibration is often needed to ensure accuracy...

Liu, G.; Liu, M.

2006-01-01T23:59:59.000Z

433

A process for selecting ecological indicators for application in monitoring impacts to Air Quality Related Values (AQRVs) from atmospheric pollutants. Final report  

SciTech Connect (OSTI)

Section 160 of the Clean Air Act (CAA) calls for measures be taken {open_quotes}to preserve, protect, and enhance air quality in national parks, national wilderness areas, national monuments, national seashores, and other areas of special national or regional natural, recreational, scenic, or historic value.{close_quotes} Pursuant to this, stringent requirement have been established for {open_quotes}Class I{close_quotes} areas, which include most National Parks and Wilderness Areas. Federal Land Managers (FLMs) are charged with the task of carrying out these requirements through the identification of air quality related values (AQRVs) that are potentially at risk from atmospheric pollutants. This is a complex task, the success of which is dependent on the gathering of information on a wide variety of factors that contribute to the potential for impacting resources in Class I areas. Further complicating the issue is the diversity of ecological systems found in Class I areas. There is a critical need for the development of monitoring programs to assess the status of AQRVs in Class I areas with respect to impacts caused by atmospheric pollutants. These monitoring programs must be based on the measurement of a carefully selected suite of key physical, chemical, and biological parameters that serve as indicators of the status of the ecosystems found in Class I areas. Such programs must be both scientifically-based and cost-effective, and must provide the data necessary for FLMs to make objective, defensible decisions. This document summarizes a method for developing AQRV monitoring programs in Class I areas.

White, G.J.; Breckenridge, R.P.

1997-01-01T23:59:59.000Z

434

Water Permits (Louisiana)  

Broader source: Energy.gov [DOE]

The Water Permits Division authorizes permits administered under the Water Quality Regulations. Louisiana's Water Quality Regulations require permits for the discharge of pollutants from any point...

435

Hydrological and water quality characteristics of three rock glaciers: Blanca Massif, Colorado, USA  

E-Print Network [OSTI]

interstitially or as discrete lenses. The geometry of a rock glacier is conducive not only to the formation and growth of ice, but also to the entrapment of water in the fluid state. It is the ice and the trapped water that are important in providing a source... and the trapped water that are important in providing a source for maintaining flow of many alpine streams during the summer. In many alpine areas of the world, streams flow from the frontal slopes of rock glaciers. Although rock glaciers have been studied...

DeMorett, Joseph Lawrence

1989-01-01T23:59:59.000Z

436

DECISION SUPPORT SYSTEM FOR MANAGEMENT OF WATER SOURCES  

E-Print Network [OSTI]

DECISION SUPPORT SYSTEM FOR MANAGEMENT OF WATER SOURCES Nejc Trdin1, 2 , Marko Bohanec1 , Mitja.bohanec}@ijs.si, mitja.janza@geo-zs.si ABSTRACT Meeting the quality criteria for drinking water is one of the areas which of data collected while monitoring water adequacy, an expert carries a large burden and also his decisions

Bohanec, Marko

437

Tennessee Water Resources Research Center Annual Technical Report  

E-Print Network [OSTI]

and administrative system for the management of water resources in Tennessee. While the situation is improving to be an abundant and good quality water supply. Historically, federal government agencies, such as the Tennessee, have been the primary contributors to the management and monitoring of water resources. In recent years

438

Signatures of Restoration and Management Changes in the Water Quality of a Central California Estuary  

E-Print Network [OSTI]

Beck, N.G. , and K.W. Bruland. 2000. Diel biogeochemicalA.T. Fisher, and K.W. Bruland. 2001. Modeling water, heat,1984; Nixon 1995; Beck and Bruland 2000; Beck et al. 2001;

Gee, Alison K.; Wasson, Kerstin; Shaw, Susan L.; Haskins, John

2010-01-01T23:59:59.000Z

439

On Managing Texas Rural Water Supply Systems: A Socioeconomic Analysis and Quality Evaluation  

E-Print Network [OSTI]

. The study uses a set of indicators to identify effectiveness and efficiency of rural water projects. Such measures for analysis and appraisal of these projects may contribute to more informed and intelligent planning for the future. The study is also...

Singh, R.N.

440

The impact of conifer harvesting on stream water quality: the Afon Hafren, mid-Wales Hydrology and Earth System Sciences, 8(3), 503520 (2004) EGU  

E-Print Network [OSTI]

The impact of conifer harvesting on stream water quality: the Afon Hafren, mid-Wales 503 Hydrology and Earth System Sciences, 8(3), 503520 (2004) © EGU The impact of conifer harvesting on stream water. The results are linked to within-catchment information to describe the influence of conifer harvesting

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Critical review: Radionuclide transport, sediment transport, and water quality mathematical modeling; and radionuclide adsorption/desorption mechanisms  

SciTech Connect (OSTI)

This report describes the results of a detailed literature review of radionuclide transport models applicable to rivers, estuaries, coastal waters, the Great Lakes, and impoundments. Some representatives sediment transport and water quality models were also reviewed to evaluate if they can be readily adapted to radionuclide transport modeling. The review showed that most available transport models were developed for dissolved radionuclide in rivers. These models include the mechanisms of advection, dispersion, and radionuclide decay. Since the models do not include sediment and radionuclide interactions, they are best suited for simulating short-term radionuclide migration where: (1) radionuclides have small distribution coefficients; (2) sediment concentrations in receiving water bodies are very low. Only 5 of the reviewed models include full sediment and radionuclide interactions: CHMSED developed by Fields; FETRA SERATRA, and TODAM developed by Onishi et al, and a model developed by Shull and Gloyna. The 5 models are applicable to cases where: (1) the distribution coefficient is large; (2) sediment concentrations are high; or (3) long-term migration and accumulation are under consideration. The report also discusses radionuclide absorption/desorption distribution ratios and addresses adsorption/desorption mechanisms and their controlling processes for 25 elements under surface water conditions. These elements are: Am, Sb, C, Ce, Cm, Co, Cr, Cs, Eu, I, Fe, Mn, Np, P, Pu, Pm, Ra, Ru, Sr, Tc, Th, {sup 3}H, U, Zn and Zr.

Onishi, Y.; Serne, R.J.; Arnold, E.M.; Cowan, C.E.; Thompson, F.L. [Pacific Northwest Lab., Richland, WA (United States)

1981-01-01T23:59:59.000Z

442

Monitoring of Total Type II Pyrethroid Pesticides in Citrus Oils and Water by Converting to a Common Product 3-Phenoxybenzoic Acid  

E-Print Network [OSTI]

Monitoring of Total Type II Pyrethroid Pesticides in Citrus Oils and Water by Converting to a Common Product 3-Phenoxybenzoic Acid Mark R. McCoy, Zheng Yang, Xun Fu,§ Ki Chang Ahn, Shirley J. Gee an alternative method that converts the type II pyrethroids to a common chemical product, 3-phenoxybenzoic acid

Hammock, Bruce D.

443

Implementation of a Geographic Information System for municipal water quality assurance  

E-Print Network [OSTI]

of Northwest Agencies with ARC/INFO Projects. . . . . . 64 I: INTRODUCTION The difficult task of watershed management involves maximizing the quality and quantity of wata for domestic, industrial, and transport uses while maintaining conditions favorable... to its ability to work with the AutoCAD drawings, the TPUW forester chose to have the Environmental Systems Research Institute's (ESRI) ARC/INFO coverages from WADNR converted to ArcCAD format. ArcCAD is a computer-aided design (CAD) system which...

Murphy, Eileen Marie

1996-01-01T23:59:59.000Z

444

A.A.C. R18-11: Water Quality Standards | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,Information Of The Transiel Method OnAand1: Water

445

ARM 17-30-101 - Water Quality: 401 Certification | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,InformationWind Energy JumpEnergyApplicationWater

446

File:06MTFShortTermWaterQualityStandardForTurbidity318Authorization.pdf |  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic UtilitiesCABConstructionStormWaterProgram.pdf Jump to: navigation,EnergyMTCDrinkingWaterPermit.pdfOpen

447

Water quality modeling for the Kennet and Avon Canal, a navigational canal in an inland catchment  

E-Print Network [OSTI]

...........................................................128 Figure 46. The outlet of Wilton Water Reservoir next to the Crofton Pumping Station. ....................................................................................................................................131 17 Figure 47. Control... waterways, cruiseways (for amenity use only), and remainder waterways, only 2000 miles (3220 km) remained (Kennet and Avon Canal Trust Ltd. 1981). Of these, 570 miles (917 km) were classified as ‘remainder’ waterways: not legally abandoned...

Zeckoski, Rebecca

2010-10-12T23:59:59.000Z

448

The Influence of Spray Water Quality on Herbicide www.btny.purdue.edu/weedscience  

E-Print Network [OSTI]

for crop protection products applications, constituting more than 95% of the spray volume. The properties calcium, magnesium, iron, aluminum, zinc, manganese, sodium, potassium, cesium, and lithium can influence. Cations dissolved in water can interact with the herbicide structure and can form complexes

449

BENEFITS OF IMPROVING WATER QUALITY IN THE ABBOTSFORD AQUIFER: AN APPLICATION OF CONTINGENT VALUATION METHODS  

E-Print Network [OSTI]

that, with further development of the region, there may be pesticide or heavy metal leaching problems of the Canadian Department of the Environment. #12;Executive Summary Nitrate pollution is a problem in many exmple of groundwater pollution. This aquifer is the primary source of municipal water for the District

450

Engineers, are focused on advanced water quality modeling on the Cumberland River in Kentucky and  

E-Print Network [OSTI]

hydropower dams in the Columbia River Basin to protect aquatic life. ORNL is providing an assessment of the effects of climate change on water availability for federal hydropower and on marketing of hydropower by increased understanding the role of climate variability and change. Collaborating with the Hydropower

451

Water Quality at Caddo Lake, Center for Invasive Species Eradication: Final Report  

E-Print Network [OSTI]

Giant salvinia, a highly invasive aquatic fern native to South America, poses a serious threat to Texas’ waters and has done so since its discovery in the state in the 1990s. If left unmanaged, giant salvinia can cause a multitude of impacts...

Gregory, L.; Knutson, A.; Ederton, E.; Mukherjee, A.; Baumann, P.; Masser, M.; Wagner, K.

2014-01-01T23:59:59.000Z

452

Appendix A. ASA's WQMAP WQMAP (Water Quality Mapping and Analysis Program) is a proprietary  

E-Print Network [OSTI]

-based personal computer. Color graphics and animation are used to display model prediction. The system-dimensional conservation of water mass, momentum, salt and energy equations on a spherical, non-orthogonal, boundary, energy, dissolved constituents, turbulent #12;294 kinetic energy, and turbulent dissipation. Implicit

Chen, Changsheng

453

Freshwater mussels and water quality: A review of the effects of hydrologic and instream habitat alterations  

E-Print Network [OSTI]

, The Ohio State University, Columbus, OH 43212 ABSTRACT: Hydraulic impacts represent a suite of habitat. These hydraulic impacts thus overlap each other to one degree or another. I have attempted to break them down to divert water to mills and turbines, where its seemingly limitless power ground grain, cut lumber

Watters, G. Thomas

454

Concept Paper for Real-Time Temperature and Water QualityManagement for San Joaquin River Riparian Habitat Restoration  

SciTech Connect (OSTI)

The San Joaquin River Riparian Habitat Restoration Program (SJRRP) has recognized the potential importance of real-time monitoring and management to the success of the San Joaquin River (SJR) restoration endeavor. The first step to realizing making real-time management a reality on the middle San Joaquin River between Friant Dam and the Merced River will be the installation and operation of a network of permanent telemetered gauging stations that will allow optimization of reservoir releases made specifically for fish water temperature management. Given the limited reservoir storage volume available to the SJJRP, this functionality will allow the development of an adaptive management program, similar in concept to the VAMP though with different objectives. The virtue of this approach is that as management of the middle SJR becomes more routine, additional sensors can be added to the sensor network, initially deployed, to continue to improve conditions for anadromous fish.

Quinn, Nigel W.T.

2004-12-20T23:59:59.000Z

455

Quality indexes based on water measurements for low and medium energy x-ray beams: A theoretical study with PENELOPE  

SciTech Connect (OSTI)

Purpose : To study the use of quality indexes based on ratios of absorbed doses in water at two different depths to characterize x-ray beams of low and medium energies. Methods : A total of 55 x-ray beam spectra were generated with the codes XCOMP5R and SPEKCALC and used as input of a series of Monte Carlo simulations performed with PENELOPE, in which the percentage depth doses in water and thek{sub Q,Q{sub 0}} factors, defined in the TRS-398 protocol, were determined for each beam. Some of these calculations were performed by simulating the ionization chamber PTW 30010. Results : The authors found that the relation betweenk{sub Q,Q{sub 0}} and the ratios of absorbed doses at two depths is almost linear. A set of ratios statistically compatible with that showing the best fit has been determined. Conclusions : The results of this study point out which of these ratios of absorbed doses in water could be used to better characterize x-ray beams of low and medium energies.

Chica, U. [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada, Spain and FISRAD S.A.S Carrera 64 a No 22-41, Bogotá D.C. (Colombia)] [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada, Spain and FISRAD S.A.S Carrera 64 a No 22-41, Bogotá D.C. (Colombia); Anguiano, M.; Lallena, A. M., E-mail: lallena@ugr.es [Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain); Vilches, M. [Servicio de Radiofísica, Hospital Universitario “San Cecilio”, Avda. Dr. Olóriz, 16, E-18012 Granada (Spain)] [Servicio de Radiofísica, Hospital Universitario “San Cecilio”, Avda. Dr. Olóriz, 16, E-18012 Granada (Spain)

2014-01-15T23:59:59.000Z

456

I.C. 39-3602 - Water Quality--Definitions | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio:GreerHiCalifornia: Energythe SecondInformation 3 -2 - Water

457

Water quality in the vicinity of Mosquito Creek Lake, Trumbull County, Ohio, in relation of the chemistry of locally occurring oil, natural gas, and brine  

SciTech Connect (OSTI)

The purpose of this report is to describe current water quality and the chemistry of oil, natural gas, and brine in the Mosquito Creek Lake area. Additionally, these data are used to characterize water quality in the Mosquito Creek Lake area in relation to past oil and natural gas well drilling and production. To meet the overall objective, several goals for this investigation were established. These include (1) collect water-quality and subsurface-gas data from shallow sediments and rock that can be used for future evaluation of possible effects of oil and natural gas well drilling and production on water supplies, (2) characterize current surface-water and ground-water quality as it relates to the natural occurrence and (or) release of oil, gas, and brine (3) sample and chemically characterize the oil in the shallow Mecca Oil Pool, gas from the Berea and Cussewago Sandstone aquifers, and the oil, gas, and brine from the Clinton sandstone, and (4) identify areas where aquifers are vulnerable to contamination from surface spills at oil and natural gas drilling and production sites.

Barton, G.J.; Burruss, R.C.; Ryder, R.T.

1998-12-31T23:59:59.000Z

458

Fish condition as an indicator of water quality in upper Galveston Bay system, Texas  

E-Print Network [OSTI]

: (Chairman of Committee) (Efead of Department) L-- ( Nle n ) b l) Annnst 1972 'LBSTMC T 1-'ish C!l!!di tion a in lnclicator of V/ater Guality in Ifpper GalvosLon Bay Syste!n, Telcas, (!&:, !gust 1972) Gary Car! . on hiatlock, B. A. , Uniuerst&qr of Te...!cas at Austin Dli-ecto!1 by: Dr. K!rk Stravim Tho Fnvironmcntal Prot" ctioil I)cjo!icy has; ':pr, !s!Sd coi!c. em thait "h! e v/aLer quality of Tr in! ty Bay viou lc bo elect!! ?Ocl a:!! Cs u It of !ious on Lightir g Llr!d Povi r Cornpu, ly's Cedar. )Baton...

Matlock, Gary C

1972-01-01T23:59:59.000Z

459

49 A.R.S. 321 et seq.: Water Quality Appeals | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights, Substantive Jump to:Species |2008 |44 Tech Inc.Program

460

ARS Title 49-200 Water Quality Control | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160 East 300 SouthWater Rights,InformationWind EnergyPublic Utilities and20249 The

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

The use of fishes in cages as biological monitors of the quality of water passing through a power plant  

E-Print Network [OSTI]

I I I \\ I 'I I I I I I 0 0 0 0 0 0 CC 0 Cl CCI (Wc!c() AXO O 3A1OSSIO CI (0 0 0 0 0 0 0 lO CC CO CC Cl QQI ~ WO/SOIIW Rrl(l!JOOQICOO 0 Ol O CO ICc 4 CC O 0 (O ) 3((!!lV83 W3j 0 R Cl W CI CC o I- Ch C' SO 4 IO 8 0 8...? O EU 8 () CC) CO IO '0 ( I 4 C) g (3 2 o CO (3 4 -~ G CO S) It) O (OI 4 0 (3 IO 4 p, I I 27 o a ao o o 0 0 0 0 0 0 0 0 0 a\\ I N ( WVH) ( N30AXO 03A105510 0 0 0 0 0 0 'O N 0 V 1V /SOHWN AAIAIAPOON00 0 N 000 I I I...

Hammerschmidt, Paul C

1973-01-01T23:59:59.000Z

462

Environmental Monitoring Plan, Revision 6  

SciTech Connect (OSTI)

The purpose of environmental monitoring is to promote the early identification of, and response to, potential adverse environmental impacts associated with Lawrence Livermore National Laboratory (LLNL) operations. Environmental monitoring supports the Integrated Safety Management System (ISMS), International Organization for Standardization (ISO) 14001 Environmental Management Systems standard, and U. S. Department of Energy (DOE) Order 458.1, Radiation Protection of the Public and the Environment. Specifically, environmental monitoring enables LLNL to detect, characterize, and respond to releases from LLNL activities; assess impacts; estimate dispersal patterns in the environment; characterize the pathways of exposure to members of the public; characterize the exposures and doses to individuals and to the population; and to evaluate the potential impacts to the biota in the vicinity of LLNL. Environmental monitoring is also a major component of compliance demonstration for permits and other regulatory requirements. The Environmental Monitoring Plan (EMP) addresses the sample collection and analytical work supporting environmental monitoring to ensure the following: (1) A consistent system for collecting, assessing, and documenting environmental data of known and documented quality; (2) A validated and consistent approach for sampling and analysis of samples to ensure laboratory data meets program-specific needs and requirements within the framework of a performance-based approach for analytical laboratory work; and (3) An integrated sampling approach to avoid duplicative data collection. LLNL prepares the EMP because it provides an organizational framework for ensuring that environmental monitoring work, which is integral to the implementation of LLNL's Environmental Management System, is conducted appropriately. Furthermore, the Environmental Monitoring Plan helps LLNL ensure compliance with DOE Order 231.1 Change 2, Environment, Safety and Health Reporting, which require the publication of an annual report that characterizes the site's environmental management performance. To summarize, the general regulatory drivers for this environmental monitoring plan are ISO 14001, DOE Order 458.1, and DOE Order 231.1. The environmental monitoring addressed by this plan includes preoperational characterization and assessment, effluent and surveillance monitoring, and permit and regulatory compliance monitoring. Additional environmental monitoring is conducted at LLNL as part of compliance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA, also known as Superfund). LLNL coordinates its ground water surveillance monitoring program with the CERCLA monitoring program to gain sampling efficiencies.

Gallegos, G M; Bertoldo, N A; Blake, R G; Campbell, C G; Grayson, A R; Nelson, J C; Revelli, M A; Rosene, C A; Wegrecki, T; Williams, R A; Wilson, K R; Jones, H E

2012-03-02T23:59:59.000Z

463

Environmental monitoring at the Lawrence Livermore National Laboratory. 1982 annual report  

SciTech Connect (OSTI)

Environmental monitoring efforts spanned air, water, vegetation and foodstuffs, and radiation doses. Monitoring data collection, analysis, and evaluation are presented for air, soils, sewage, water, vegetation and foodstuffs, milk, and general environmental radioactivity. Non-radioactive monitoring addresses beryllium, chemical effluents in sewage, noise pollution, and storm runoff and liquid discharge site pollutants. Quality assurance efforts are addressed. Five appendices present tabulated data; environmental activity concentration; dose calculation method; discharge limits to sanitary sewer systems of Livermore; and sampling and analytical procedures for environmental monitoring. (PSB)

Griggs, K.S.; Gonzalez, M.A.; Buddemeier, R.W.

1983-03-14T23:59:59.000Z

464

WATER-QUALITY CONDITIONS DURING LOW FLOW IN THE LOWER YOUGHIOGHENY RIVER BASIN, PENNSYLVANIA, OCTOBER 5-7, 1998  

SciTech Connect (OSTI)

In October 1998, a chemical synoptic survey was conducted by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, National Energy Technology Laboratory, in the Lower Youghiogheny River Basin in Pennsylvania to give a snap-shot of present (1998) water quality during low-flow conditions. Water samples from 38 sites--12 mainstem sites, 22 tributaries, and 4 mine discharges that discharge directly to the Youghiogheny River--were used to identify sources of contaminants from mining operations. Specific conductance, water temperature, pH, and dissolved oxygen were measured in the field at each site and concentrations of major ions and trace elements were measured in the laboratory. Unaccounted for gains and losses in streamflow were measured during the study. Unaccounted for losses in streamflow might be attributed to water loss through streambed fractures. Extensive mine tunnels are present in the basin and loss of water to these tunnels seems likely. Unaccounted for gains in streamflow may be from unmeasured tributaries or surface seeps, but most of the gains are suspected to come from artesian flow through fractures in the streambed from underground mine pools. Influent flows of rust-colored water were noted in some river sections. The pH values for all the samples collected during this survey were above 5.8, and most (33 of 38 samples) were above 7.0. Samples from the four mine-discharge sites also had pH values between 6.3 and 6.7. The lowest pH (5.8) was in a tributary, Galley Run. All 38 sampling sites had net alkalinity. The alkalinity load in the Youghiogheny River increased between Connellsville and McKeesport from 35 to 79 tons per day. Above Smithton, the measured alkalinity load in the Lower Youghiogheny River agreed well with the estimated alkalinity load. Below Smithton, measured alkalinity loads in the Lower Youghiogheny River are greater than calculated loads, resulting in unaccounted for gains in alkalinity. These gains are believed to be from seeps in the streambed. Approximately one-third of the load of total alkalinity in the Youghiogheny River at McKeesport is attributed to Sewickley Creek, which contributes 14 tons per day. Sulfate concentrations in the Youghiogheny River steadily increase from 33 milligrams per liter at Connellsville to 77 milligrams per liter near McKeesport. The measured concentrations of sulfate exceeded Pennsylvania water-quality standards at four tributary sites (Galley Run, Hickman Run, Sewickley Creek, and Gillespie Run) and all four mine-discharge sites but not at any main-stem sites. A large increase in sulfate load between West Newton and Sutersville can be attributed almost entirely to the contribution from Sewickley Creek (49 tons per day). Approximately 25 percent of the load measured between Connellsville and McKeesport is unaccounted for. These gains are believed to be from seeps in the streambed from underground mine pools. Similar patterns also were observed for loads of sodium, calcium, and magnesium. Unmeasured inputs from mine rainage are believed to be the source of these loads. Elevated concentrations (above background levels) of chemicals associated with drainage from coal-mining operations were measured in samples from tributaries, especially from Galley Run, Gillespie Run, and Sewickley Creek, and from the mine-discharge sites. The synoptic survey conducted for this study was successful in identifying generalized reaches of the Youghiogheny River where unaccounted for loads of constituents associated with mining activities are entering the river. However, the survey was not able to pinpoint the location of these loads. Remote-sensing techniques, such as thermal infrared imaging by the National Energy Technology Laboratory, could be useful for determining the precise locations of these inputs.

James I. Sams, III, Karl T. Schroeder; Terry E. Ackman; J. Kent Crawford; Kim L. Otto

2001-01-01T23:59:59.000Z

465

UMTRA project water sampling and analysis plan -- Shiprock, New Mexico  

SciTech Connect (OSTI)

Water sampling and analysis plan (WSAP) is required for each U.S. Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site to provide a basis for ground water and surface water sampling at disposal and former processing sites. This WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring stations at the Navaho Reservation in Shiprock, New Mexico, UMTRA Project site. The purposes of the water sampling at Shiprock for fiscal year (FY) 1994 are to (1) collect water quality data at new monitoring locations in order to build a defensible statistical data base, (2) monitor plume movement on the terrace and floodplain, and (3) monitor the impact of alluvial ground water discharge into the San Juan River. The third activity is important because the community of Shiprock withdraws water from the San Juan River directly across from the contaminated alluvial floodplain below the abandoned uranium mill tailings processing site.

Not Available

1994-02-01T23:59:59.000Z

466

Biomass production, forage quality, and cation uptake of Quail bush, four-wing saltbush, and seaside barley irrigated with moderately saline-sodic water  

SciTech Connect (OSTI)

The study reported here investigated capacity of Atriplex lentiformis (Torr.) S. Wats. (Quail bush), Atriplex X aptera A. Nels. (pro sp.) (Wytana four-wing saltbush), and Hordeum marinum Huds. (seaside barley) to produce biomass and crude protein and take up cations when irrigated with moderately saline-sodic water, in the presence of a shallow water table. Water tables were established at 0.38, 0.76, and 1.14m below the surface in sand-filled columns. The columns were then planted to the study species. Study plants were irrigated for 224 days; irrigation water was supplied every 7 days equal to water lost to evapotranspiration (ET) plus 100mL (the volume of water removed in the most previous soil solution sampling). Water representing one of two irrigation sources was used: Powder River (PR) or coalbed natural gas (CBNG) wastewater. Biomass production did not differ significantly between water quality treatments but did differ significantly among species and water table depth within species. Averaged across water quality treatments, Hordeum marinum produced 79% more biomass than A. lentiformis and 122% more biomass than Atriplex X aptera, but contained only 11% crude protein compared to 16% crude protein in A. lentiformis and 14% crude protein in Atriplex X aptera. Atriplex spp. grown in columns with the water table at 0.38m depth produced more biomass, took up less calcium on a percentage basis, and took up more sodium on a percentage basis than when grown with the water table at a deeper depth. Uptake of cations by Atriplex lentiformis was approximately twice the uptake of cations by Atriplex X aptera and three times that of H. marinum. After 224 days of irrigation, crop growth, and cation uptake, followed by biomass harvest, EC and SAR of shallow groundwater in columns planted to A. lentiformis were less than EC and SAR of shallow ground water in columns planted to either of the other species.

Bauder, J.W.; Browning, L.S.; Phelps, S.D.; Kirkpatrick, A.D. [Montana State University, Bozeman, MT (United States)

2008-07-01T23:59:59.000Z

467

Monitoring well  

DOE Patents [OSTI]

The present invention relates to a monitoring well which includes an enclosure defining a cavity and a water reservoir enclosed within the cavity and wherein the reservoir has an inlet and an outlet. The monitoring well further includes a porous housing borne by the enclosure and which defines a fluid chamber which is oriented in fluid communication with the outlet of the reservoir, and wherein the porous housing is positioned in an earthen soil location below-grade. A geophysical monitoring device is provided and mounted in sensing relation relative to the fluid chamber of the porous housing; and a coupler is selectively moveable relative to the outlet of reservoir to couple the porous housing and water reservoir in fluid communication. An actuator is coupled in force transmitting relation relative to the coupler to selectively position the coupler in a location to allow fluid communication between the reservoir and the fluid chamber defined by the porous housing.

Hubbell, Joel M. (Idaho Falls, ID); Sisson, James B. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

468

Environmental monitoring report, May 10, 1993--June 1, 1994  

SciTech Connect (OSTI)

The Tennessee Department of Environment and Conservation (TDEC) DOE Oversight Division (DOE-O) monitoring effort will serve as oversight with ongoing compliance and ambient sampling by Oak Ridge Reservation (ORR), Department of Energy (DOE) and contractor staff programs. These sources provide a comprehensive database which must be reviewed and analyzed in order to streamline DOE-O sampling efforts. DOE-O monitoring is necessary to provide quality control, to ensure compliance, to ensure completeness, and to assure protection of public health and the environment. The Tennessee Oversight Agreement (TOA), includes a section on Environmental Monitoring as Attachment A. To accomplish these objectives, DOE-O will implement the following monitoring programs: surface waters; ground water; air; fish and wildlife. In addition, radiation monitoring has been conducted in all of these areas.

Not Available

1994-09-01T23:59:59.000Z

469

Environmental control technology survey of selected US strip mining sites. Volume 2B. Alabama. Water quality impacts and overburden chemistry of Alabama study site  

SciTech Connect (OSTI)

As part of a program to examine the ability of existing control technologies to meet federal guidelines for the quality of aqueous effluents from coal mines, an intensive study of water, coal, and overburden chemistry was conducted at a surface coal mine in Alabama from May 1976 through July 1977. Sampling sites included the pit sump, a stream downgrade from the mine, the discharge from the water treatment facility, and a small stream outside the mine drainage. Water samples were collected every two weeks by Argonne subcontractors at the Alabama Geological Survey and analysed for the following parameters: specific conductance, pH, temperature, acidity, bicarbonate, carbonate, chloride, total dissolved solids, suspended solids, sulfate, and 20 metals. Analysis of the coal and overburden shows that no potential acid problem exists at this mine. Water quality is good in both streams sampled, and high levels of dissolved elements are found only in water collected from the pit sump. The mine effluent is in compliance with Office of Surface Mining water quality standards.

Henricks, J D; Bogner, J E; Olsen, R D; Schubert, J P; Sobek, A A; Johnson, D O

1980-05-01T23:59:59.000Z

470

Mississippi Water Resources Research Institute Annual Technical Report  

E-Print Network [OSTI]

include: water quality, surface and groundwater management, water quality management and water resources Category: Water Quality Focus Category: Wetlands, Water Quality, Management and Planning Descriptors; to assist state agencies in the development and maintenance of a state water management plan

471

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms  

SciTech Connect (OSTI)

An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found to work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

Apte, Michael G.; Norman, Bourassa; Faulkner, David; Hodgson, Alfred T.; Hotchi, Toshfumi; Spears, Michael; Sullivan, Douglas P.; Wang, Duo

2008-04-04T23:59:59.000Z

472

Application of a spatially referenced water quality model to predict E. coli flux in two Texas river basins  

E-Print Network [OSTI]

of contaminants collected at monitoring stations for the prediction, the effect of the locations and selections of the monitoring stations was analyzed. The results of SPARROW application were studied in detail to evaluate the contribution from the statistically...

, Deepti

2009-05-15T23:59:59.000Z

473

Groundwater monitoring at the Waste Isolation Pilot Plant  

SciTech Connect (OSTI)

This paper discusses the Groundwater Monitoring Program (GPM) being conducted at the Waste Isolation Pilot Plant (WIPP) in Carlsbad, New Mexico. The Regulatory and Environmental Programs (REP) section of the Environment, Safety and Health department (ES H) is responsible for conducting environmental monitoring at the WIPP. Groundwater monitoring is one of the ongoing environmental activities currently taking place. The REP section includes water quality sampling and water level monitoring. The WIPP Project is a research and develop facility designed to demonstrate the safe disposal of defense-generated waste in a geologic repository. Water quality sampling for physical, chemical, and radiological parameters has been an ongoing activity at the WIPP site for the past six years, and will continue through the life of the project. The water quality of a well is sampled while the well is continuously pumped. Serial samples of the pumped water are collected and tested for pH, Eh, temperature, specific gravity, specific conductivity, alkalinity, chlorides, divalent cations, ferrous iron, and total iron. Stabilization of serial sampling parameters determined if a representative sample is being obtained, Representative samples are sent to contract laboratories and analyzed for general chemistry, major cations and anions, and radionuclides. 13 refs., 4 figs., 1 tab.

Kehrman, R.; Broberg, K.; Tatro, G.; Richardson, R.; Dasczcyszak, W.

1990-01-01T23:59:59.000Z

474

Impacts of Motor Vehicle Operation on Water Quality in the United States - Clean-up Costs and Policies  

E-Print Network [OSTI]

of structural storm-water best management practices. Waterbest management practices (BMPs) for removing them. Storm-water

Nixon, Hilary; Saphores, Jean-Daniel

2007-01-01T23:59:59.000Z

475

Creating solutions for water quality issues in New Jersey It has been a year since our last newsletter, so we have a lot of  

E-Print Network [OSTI]

Jersey designs stormwater best management practices (BMPs) for the water quality design storm of 1 and graphic design, and stormwater best management practice design. Hae-An received a Master of Architecture a background in ecological restoration, watershed assessment and planning, stormwater best management practice

Goodman, Robert M.

476

Presented at 2012 IEEE Systems and Information Engineering Design Symposium, University of Virginia, April 27, 2012 Abstract--The water quality in the West and Rhode Rivers  

E-Print Network [OSTI]

Presented at 2012 IEEE Systems and Information Engineering Design Symposium, University of Virginia, April 27, 2012 Abstract-- The water quality in the West and Rhode Rivers (WRR), two mezohaline sub be the most cost-effective and sustainable alternative. I. INTRODUCTION HE West and Rhode rivers are two sub

477

Improving water quality with a "territorial" agri-environmental policy? Insights from the new generation AES in South-West France  

E-Print Network [OSTI]

1 Improving water quality with a "territorial" agri-environmental policy? Insights from the new with the Local Agri-Environmental Schemes (LAES), the French contractual policy instrument within the European underlie the French agri-environmental policy, from a retrospective of the successive national schemes set

Paris-Sud XI, Université de

478

Use of Treated Municipal Wastewater as Power Plant Cooling System Makeup Water: Tertiary Treatment versus Expanded Chemical Regimen for Recirculating Water Quality Management  

SciTech Connect (OSTI)

Treated municipal wastewater is a common, widely available alternative source of cooling water for thermoelectric power plants across the U.S. However, the biodegradable organic matter, ammonia-nitrogen, carbonate and phosphates in the treated wastewater pose challenges with respect to enhanced biofouling, corrosion, and scaling, respectively. The overall objective of this study was to evaluate the benefits and life cycle costs of implementing tertiary treatment of secondary treated municipal wastewater prior to use in recirculating cooling systems. The study comprised bench- and pilot-scale experimental studies with three different tertiary treated municipal wastewaters, and life cycle costing and environmental analyses of various tertiary treatment schemes. Sustainability factors and metrics for reuse of treated wastewater in power plant cooling systems were also evaluated. The three tertiary treated wastewaters studied were: secondary treated municipal wastewater subjected to acid addition for pH control (MWW_pH); secondary treated municipal wastewater subjected to nitrification and sand filtration (MWW_NF); and secondary treated municipal wastewater subjected nitrification, sand filtration, and GAC adsorption (MWW_NFG). Tertiary treatment was determined to be essential to achieve appropriate corrosion, scaling, and biofouling control for use of secondary treated municipal wastewater in power plant cooling systems. The ability to control scaling, in particular, was found to be significantly enhanced with tertiary treated wastewater compared to secondary treated wastewater. MWW_pH treated water (adjustment to pH 7.8) was effective in reducing scale formation, but increased corrosion and the amount of biocide required to achieve appropriate biofouling control. Corrosion could be adequately controlled with tolytriazole addition (4-5 ppm TTA), however, which was the case for all of the tertiary treated waters. For MWW_NF treated water, the removal of ammonia by nitrification helped to reduce the corrosivity and biocide demand. Also, the lower pH and alkalinity resulting from nitrification reduced the scaling to an acceptable level, without the addition of anti-scalant chemicals. Additional GAC adsorption treatment, MWW_NFG, yielded no net benefit. Removal of organic matter resulted in pitting corrosion in copper and cupronickel alloys. Negligible improvement was observed in scaling control and biofouling control. For all of the tertiary treatments, biofouling control was achievable, and most effectively with pre-formed monochloramine (2-3 ppm) in comparison with NaOCl and ClO2. Life cycle cost (LCC) analyses were performed for the tertiary treatment systems studied experimentally and for several other treatment options. A public domain conceptual costing tool (LC3 model) was developed for this purpose. MWW_SF (lime softening and sand filtration) and MWW_NF were the most cost-effective treatment options among the tertiary treatment alternatives considered because of the higher effluent quality with moderate infrastructure costs and the relatively low doses of conditioning chemicals required. Life cycle inventory (LCI) analysis along with integration of external costs of emissions with direct costs was performed to evaluate relative emissions to the environment and external costs associated with construction and operation of tertiary treatment alternatives. Integrated LCI and LCC analysis indicated that three-tiered treatment alternatives such as MWW_NSF and MWW_NFG, with regular chemical addition for treatment and conditioning and/or regeneration, tend to increase the impact costs and in turn the overall costs of tertiary treatment. River water supply and MWW_F alternatives with a single step of tertiary treatment were associated with lower impact costs, but the contribution of impact costs to overall annual costs was higher than all other treatment alternatives. MWW_NF and MWW_SF alternatives exhibited moderate external impact costs with moderate infrastructure and chemical conditioner dosing, which makes them (especially

David Dzombak; Radisav Vidic; Amy Landis

2012-06-30T23:59:59.000Z

479

Evaluation of Phytoremediation of Coal Bed Methane Product Water and Waters of Quality Similar to that Associated with Coal Bed Methane Reserves of the Powder River Basin, Montana and Wyoming  

SciTech Connect (OSTI)

U.S. emphasis on domestic energy independence, along with advances in knowledge of vast biogenically sourced coalbed methane reserves at relatively shallow sub-surface depths with the Powder River Basin, has resulted in rapid expansion of the coalbed methane industry in Wyoming and Montana. Techniques have recently been developed which constitute relatively efficient drilling and methane gas recovery and extraction techniques. However, this relatively efficient recovery requires aggressive reduction of hydrostatic pressure within water-saturated coal formations where the methane is trapped. Water removed from the coal formation during pumping is typically moderately saline and sodium-bicarbonate rich, and managed as an industrial waste product. Current approaches to coalbed methane product water management include: surface spreading on rangeland landscapes, managed irrigation of agricultural crop lands, direct discharge to ephermeral channels, permitted discharge of treated and untreated water to perennial streams, evaporation, subsurface injection at either shallow or deep depths. A Department of Energy-National Energy Technology Laboratory funded research award involved the investigation and assessment of: (1) phytoremediation as a water management technique for waste water produced in association with coalbed methane gas extraction; (2) feasibility of commercial-scale, low-impact industrial water treatment technologies for the reduction of salinity and sodicity in coalbed methane gas extraction by-product water; and (3) interactions of coalbed methane extraction by-product water with landscapes, vegetation, and water resources of the Powder River Basin. Prospective, greenhouse studies of salt tolerance and water use potential of indigenous, riparian vegetation species in saline-sodic environments confirmed the hypothesis that species such as Prairie cordgrass, Baltic rush, American bulrush, and Nuttall's alkaligrass will thrive in saline-sodic environments when water supplies sourced from coalbed methane extraction are plentiful. Constructed wetlands, planted to native, salt tolerant species demonstrated potential to utilize substantial volumes of coalbed methane product water, although plant community transitions to mono-culture and limited diversity communities is a likely consequence over time. Additionally, selected, cultured forage quality barley varieties and native plant species such as Quail bush, 4-wing saltbush, and seaside barley are capable of sustainable, high quality livestock forage production, when irrigated with coalbed methane product water sourced from the Powder River Basin. A consequence of long-term plant water use which was enumerated is elevated salinity and sodicity concentrations within soil and shallow alluvial groundwater into which coalbed methane product water might drain. The most significant conclusion of these investigations was the understanding that phytoremediation is not a viable, effective technique for management of coalbed methane product water under the present circumstances of produced water within the Powder River Basin. Phytoremediation is likely an effective approach to sodium and salt removal from salt-impaired sites after product water discharges are discontinued and site reclamation is desired. Coalbed methane product water of the Powder River Basin is most frequently impaired with respect to beneficial use quality by elevated sodicity, a water quality constituent which can cause swelling, slaking, and dispersion of smectite-dominated clay soils, such as commonly occurring within the Powder River Basin. To address this issue, a commercial-scale fluid-bed, cationic resin exchange treatment process and prototype operating treatment plant was developed and beta-tested by Drake Water Technologies under subcontract to this award. Drake Water Technologies secured U.S. Patent No. 7,368,059-B2, 'Method for removal of benevolent cations from contaminated water', a beta Drake Process Unit (DPU) was developed and deployed for operation in the Powder River Basin. First year operatio

James Bauder

2008-09-30T23:59:59.000Z

480

Tennessee Water Resources Research Center Annual Technical Report  

E-Print Network [OSTI]

moved to establish an integrated and coordinated policy and administrative system for the management of Tennessee Tennessee is fortunate to have what many consider to be an abundant and good quality water supply to the management and monitoring of water resources. In recent years, however, the State, through the Tennessee

Note: This page contains sample records for the topic "water quality monitoring" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Water Resources Advisory Panel Updates By Rachael Herpel,  

E-Print Network [OSTI]

of invasive species (i.e., Phragmites australis) for their study of riparian vegetation impacts on water feet to be taller than the Phragmites being studied. Water quality monitoring equipment was also installed at three locations. After collecting baseline data, Phragmites will be removed

Nebraska-Lincoln, University of

482

An evaluation of hydrologic, geotechnical, and chemical behavior of processed oil shale solid waste 2; The use of time domain reflectometry (TDR) for monitoring in-situ volumetric water content in processed oil shale  

SciTech Connect (OSTI)

This paper describes the use of time domain reflectometry (TDR) for monitoring volumetric water contents in processed oil shale solid waste. TDR measures soil water content via a correlation between the dielectric constant (K) of the 3 phase (soil-water-air) system and the volumetric water content ({theta}{sub v}). An extensive bench top research program has been conducted to evaluate and verify the use of this technique in processed oil shale solid waste. This study utilizes columns of processed oil shale packed to known densities and varying water contents and compares the columetric water content measured via TDR and the volumetric water content measured through gravimetric determination.

Reeves, T.L.; Elgezawi, S.M. (Wyoming Univ., Laramie, WY (USA). Dept. of Civil Engineering); Kaser, T.G. (GIGO Computer and Electronic, Laramie, WY (US))

1989-01-01T23:59:59.000Z

483

Computeer-based decision support tools for evaluation of actions affecting flow and water quality in the San Joaquin Basin  

SciTech Connect (OSTI)

This document is a preliminary effort to draw together some of the important simulation models that are available to Reclamation or that have been developed by Reclamation since 1987. This document has also attempted to lay out a framework by which these models might be used both for the purposes for which they were originally intended and to support the analysis of other issues that relate to the hydrology and to salt and water quality management within the San Joaquin Valley. To be successful as components of a larger Decision Support System the models should to be linked together using custom designed interfaces that permit data sharing between models and that are easy to use. Several initiatives are currently underway within Reclamation to develop GIS - based and graphics - based decision support systems to improve the general level of understanding of the models currently in use, to standardize the methodology used in making planning and operations studies and to permit improved data analysis, interpretation and display. The decision support systems should allow greater participation in the planning process, allow the analysis of innovative actions that are currently difficult to study with present models and should lead to better integrated and more comprehensive plans and policy decisions in future years.

Quinn, N.W.T.

1993-01-01T23:59:59.000Z

484

Cost reduction performance enhancements of multiple site cooling water systems, enabled by remote system monitoring/control and multifaceted data management  

SciTech Connect (OSTI)

An outsourced cooling water treatment automated control and data acquisition package, has been designed, installed, and commissioned in over 70 sites in North America and offshore. The standard package consists of a controller, sensors, human-machine interface software, data acquisition and management software, communications, and reporting. Significant challenges to applying this standard package in multiple sites arose from variations in cooling system design and makeup water quality as well as operations, environmental considerations, metrics, and language. A standard approach has met these challenges and overcome effects of downsizing through significant reduction in non-value-added, manual activities. Overall system reliability has been improved by migration to best practice throughout the organizations involved and immediate proactive response to out-of-specification conditions. This paper documents the evolution of a standard cooling water automation and data management package from its inception to current practice.

Cook, B. [BetzDearborn Water Management Group, Horsham, PA (United States); Young, D. [BetzDearborn Water Management Group, Mississauga, Ontario (Canada); Tari, K. [Praxair, Inc., Tonawanda, New York, NY (United States)

1998-12-31T23:59:59.000Z

485

Managing For High-quality Hay  

E-Print Network [OSTI]

This publication highlights the factors determining hay quality and discusses fertility and water interaction, harvesting, quality losses and storage losses....

Stichler, Charles; Bade, David H.

1998-09-22T23:59:59.000Z

486

The culture of marine fish and their use as biological monitors of water quality in ponds receiving heated discharge water from a power station  

E-Print Network [OSTI]

Map showing location of power plant snd research facilities. 12 Diagram showing research facilities. Ponds numbered 1 through 25 from west to east. Daily hydrological data for the intake canal (Janu- ary 23, 1973 ? March 5, 1974... pond was approximately 0. 1 ha in surface area, 82. 3 m long, TS 00 SS 20 COOI INC IAXE 29 ~ 5 INTAKE AREA RESEARCH I CILITIES DISCHAROE CANAL POWER PLANT CEOAR RATOU TRINITY SAY ~ 0 0% M 0 0 OO . ~, OO 0 0 +I 0 Oll CLI 0 HLI 08 ~ '0...

Linder, Donald Ray

1974-01-01T23:59:59.000Z

487

Environmental monitoring plan, July 1--December 31, 1994  

SciTech Connect (OSTI)

The Tennessee Department of Environment and Conservation, DOE Oversight Division (TDEC/DOE-O) under the terms of the Tennessee Oversight Agreement (TOA) are providing annual reports: reporting of State`s monitoring and analysis, and findings of DOE`s quality and effectiveness of DOE`s monitoring and surveillance. This report blends some of both of the required annual reports as described in the TOA section A.7.2.2. The Federal Facilities Agreement (FFA) integrates the Resource Conservation and Recovery Act (RCRA) and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) for the Oak Ridge Reservation. This report presents the results of environmental monitoring in Tennessee in the following areas: surface waters; ground water; air; and fish and wildlife. In addition, radiation monitoring has been conducted in all of these areas.

Not Available

1994-07-01T23:59:59.000Z

488

Authority of states of use section 401 water quality certification to deny or condition Federal Energy Regulatory Commission licenses. Master's thesis  

SciTech Connect (OSTI)

This thesis discusses a recent United States Supreme Court case that will have a profound influence on the licensure of hydroelectric projects and the related ability of States to protect the quality of their waters. On October 4, 1993, the Supreme Court granted a Writ of Certiorari to resolve a conflict among the state courts of last resort. This case involves two fundamental and competing national interests: the nation's thirst for cheap, dependable power versus its equally strong desire to improve the quality of its water resources. It also involves two underlying regulatory regimes that overlap and conflict with each other in some ways. This case illustrates how those two national interests and their underlying regulatory regimes cannot always be reconciled. It also demonstrates how Congress, with its muddled ways of passing legislation, can create conflicts between federal and state regulatory agencies.

Hart, E.O.

1994-09-01T23:59:59.000Z

489

Work plan for monitor well installation water and sediment sample collection aquifer testing and topographic surveying at the Riverton, Wyoming, UMTRA Project Site  

SciTech Connect (OSTI)

Investigations conducted during preparation of the site observational work plan (SOWP) at the Uranium Mill Tailings Remedial Action (UMTRA) Project site support a proposed natural flushing ground water compliance strategy, with institutional controls. However, additional site-specific data are needed to reduce uncertainties in order to confirm the applicability and feasibility of this proposed compliance strategy option. This proposed strategy will be analyzed in the site-specific environmental assessment. The purpose of this work plan is to summarize the data collection objectives to fill those data needs, describe the data collection activities that will be undertaken to meet those objectives, and elaborate on the data quality objectives which define the procedures that will be followed to ensure that the quality of these data meet UMTRA Project needs.

NONE

1995-06-01T23:59:59.000Z

490

S-K Final Report Project Title: Examination of Coastal Aquaculture Effluent and Receiving Water Quality throughout the  

E-Print Network [OSTI]

Bratvold Savannah River Ecology Laboratory University of Georgia Date: October 31, 2005 Abstract. The receiving water for this facility is an intercoastal water way. The second facility is a small operation

491

A field-based study of alternative microbial indicator tests for drinking water quality in Northern Ghana  

E-Print Network [OSTI]

Safe drinking water is essential for human survival, yet it is unavailable to over 1 billion of the world's people living in poverty (World Bank, 2009). The current methods used to identify drinking water sources are ...

O'Keefe, Samantha F

2012-01-01T23:59:59.000Z

492

M-area hazardous waste management facility groundwater monitoring and corrective-action report, First quarter 1995, Volume 1  

SciTech Connect (OSTI)

This report, in three volumes, describes the ground water monitoring and c corrective-action program at the M-Area Hazardous Waste Management Facility (HWMF) at the Savannah River Site (SRS) during the fourth quarter 1994 and first quarter 1995. Concise description of the program and considerable data documenting the monitoring and remedial activities are included in the document. This is Volume 1 covering the following topics: sampling and results; hydrogeologic assessment; water quality assessment; effectiveness of the corrective-action program; corrective-action system operation and performance; monitoring and corrective-action program assessment; proposed monitoring and corrective-action program modifications. Also included are the following appendicies: A-standards; B-flagging criteria; C-figures; D-monitoring results tables; E-data quality/usability assessment.

NONE

1995-05-01T23:59:59.000Z

493

Experimental investigation of a flow monitoring instrument in an upper plenum of an air-water reflood test facility. [PWR  

SciTech Connect (OSTI)

Instrumentation was developed for measuring fluid phenomena in the upper plenum of pressurized water reactor reflood facilities. In particular, the instrumentation measured two-phase flow velocity and void fraction. The principle of operation of the instrumentation scheme was based on the measurement of electrical impedance. The technique of analysis of random signals from two spatially separated impedance sensors was employed to measure two-phase flow velocity. A relative admittance technique was used to determine void fraction. The performance of the instrumentaton was studied in an air-water test facility.

Combs, S.K.; Hardy, J.E.

1980-01-01T23:59:59.000Z

494

Inventory of current environmental monitoring projects in the US-Canadian transboundary region  

SciTech Connect (OSTI)

This document presents the results of a study commissioned to survey and summarize major environmental monitoring projects in the US-Canadian transboundary region. Projects with field sites located within 400 km (250 mi) of the border and active after 1980 were reviewed. The types of projects included: ambient air-quality monitoring, ambient water-quality monitoring, deposition monitoring, forest/vegetation monitoring and research, soil studies, and ecosystem studies. Ecosystem studies included projects involving the measurement of parameters from more than one monitoring category (e.g., studies that measured both water and soil chemistry). Individual descriptions were formulated for 184 projects meeting the spatial and temporal criteria. Descriptions included the official title for the project, its common abbreviation, program emphasis, monitoring site locations, time period conducted, parameters measured, protocols employed, frequency of sample collection, data storage information, and the principal contact for the project. A summary inventory subdivided according to the six monitoring categories was prepared using a computerized data management system. Information on major centralized data bases in the field of environmental monitoring was also obtained, and summary descriptions were prepared. The inventory and data base descriptions are presented in appendices to this document.

Glantz, C.S.; Ballinger, M.Y.; Chapman, E.G.

1986-05-01T23:59:59.000Z

495

Groundwater Quality Rules (New Jersey)  

Broader source: Energy.gov [DOE]

The protection of ambient ground water quality through the establishment of constituent standards for ground water pollutants is the subject of this chapter. These constituent standards are...

496

Some Simple Principles in the Collection of Engineering and Quality Assurance Whether data are to be used to monitor process stability/performance or to guide changes  

E-Print Network [OSTI]

Some Simple Principles in the Collection of Engineering and Quality Assurance Data Whether data. (For example, a blanket "take a 10% sample" rule will sometimes over-sample and sometimes under presentation quality displays. 6. In order to be useful in indicating sources of variation in a data set, care

Vardeman, Stephen B.

497

Calendar Year 2007 Groundwater Monitoring Report, U.S. Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

This report contains the groundwater and surface water monitoring data that were obtained during calendar year (CY) 2007 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (hereafter referenced as Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The CY 2007 monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12 (Figure A.1). The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system). The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Section 2 of this report provides background information pertinent to groundwater and surface water quality monitoring in each hydrogeologic regime, including the topography and bedrock geology, surface water drainage, groundwater system, and extent of groundwater contamination. The CY 2007 groundwater and surface water monitoring data in this report were obtained from sampling and analysis activities implemented under the Y-12 Groundwater Protection Program (GWPP) managed by BWXT Y-12, L.L.C. (BWXT), and from sampling and analysis activities implemented under several monitoring programs managed by Bechtel Jacobs Company LLC (BJC). In December 2007, the BWXT corporate name was changed to Babcock & Wilcox Technical Services Y-12, LLC (B&W Y-12), which is applied to personnel and organizations throughout CY 2007 for this report. Cooperative implementation of the monitoring programs directed by the Y-12 GWPP and BJC (i.e., coordinating sample collection and sharing data) ensures that the CY 2007 monitoring results fulfill requirements of all the applicable monitoring drivers with no duplication of sampling and analysis efforts. Section 3 of this report contains a summary of information regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP including sampling locations and frequency; quality assurance (QA)/quality control (QC) sampling; sample collection and handling; field measurements and laboratory analytes; data management and data quality objective (DQO) evaluation; and groundwater elevation monitoring. However, this report does not include equivalent information regarding the groundwater and surface water sampling and analysis activities associated with the monitoring programs implemented by BJC. Such details are deferred to the respective programmatic plans and reports issued by BJC (see Section 3.0). Collectively, the groundwater and surface water monitoring data obtained during CY 2007 by the Y-12 GWPP and BJC address DOE Order 450.1 (Environmental Protection Program) requirements for monitoring groundwater and surface water quality in areas: (1) which are, or could be, affected by operations at Y-12 (surveillance monitoring); and (2) where contaminants from Y-12 are most likely to migrate beyond the boundaries of the ORR (exit pathway/perimeter monitoring). Section 4 of this report presents a summary evaluation of the monitoring data with regard to the respective objectives of surveillance monitoring and exit pathway/perimeter monitoring, based on the analytical results for the principal groundwater and surface water contaminants at Y-12: nitrate, uranium, volatile organic compounds (VOCs), gross alpha activity, and gross beta activity. Section 5 of this report summarizes the most pertinent findings regarding the principal contaminants, along with recommendations proposed for ongoing groundwater and surface water quality monitoring performed under the Y-12 GWPP.

Elvado Environmental LLC

2008-12-01T23:59:59.000Z

498

Calendar Year 2006 Groundwater Monitoring Report, U.S Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee  

SciTech Connect (OSTI)

This report contains the groundwater and surface water monitoring data that were obtained during calendar year (CY) 2006 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (hereafter referenced as Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The CY 2006 monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12 (Figure A.1). The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system). The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Section 2 of this report provides background information pertinent to groundwater and surface water quality monitoring in each hydrogeologic regime, including the topography and bedrock geology, surface water drainage, groundwater system, and extent of groundwater contamination. The CY 2006 groundwater and surface water monitoring data in this report were obtained from sampling and analysis activities implemented under the Y-12 Groundwater Protection Program (GWPP) managed by BWXT Y-12, L.L.C. (BWXT), and from sampling and analysis activities implemented under several monitoring programs managed by Bechtel Jacobs Company LLC (BJC). Cooperative implementation of the monitoring programs directed by the Y-12 GWPP and BJC (i.e., preparing SAPs, coordinating sample collection, and sharing data) ensures that the CY 2006 monitoring results fulfill requirements of all the applicable monitoring drivers with no duplication of sampling and analysis efforts. Section 3 of this report contains a summary of information regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP including sampling locations and frequency; quality assurance (QA)/quality control (QC) sampling; sample collection and handling; field measurements and laboratory analytes; data management and data quality objective (DQO) evaluation; and groundwater elevation monitoring. However, this report does not include equivalent information regarding the groundwater and surface water sampling and analysis activities associated with the monitoring programs implemented by BJC. Such details are deferred to the respective programmatic plans and reports issued by BJC (see Section 3.0). Collectively, the groundwater and surface water monitoring data obtained during CY 2006 by the Y-12 GWPP and BJC address DOE Order 450.1 (Environmental Protection Program) requirements for monitoring groundwater and surface water quality in areas: (1) which are, or could be, affected by operations at Y-12 (surveillance monitoring); and (2) where contaminants from Y-12 are most likely to migrate beyond the boundaries of the ORR (exit pathway/perimeter monitoring). Section 4 of this report presents a summary evaluation of the monitoring data with regard to the respective objectives of surveillance monitoring and exit pathway/perimeter monitoring, based on the analytical results for the principal groundwater and surface water contaminants at Y-12: nitrate, uranium, volatile organic compounds (VOCs), gross alpha activity, and gross beta activity. Section 5 of this report summarizes the most pertinent findings regarding the principal contaminants, along with recommendations proposed for ongoing groundwater and surface water quality monitoring performed under the Y-12 GWPP. Narrative sections of this report reference several appendices. Figures (maps and diagrams) and tables (excluding data summary tables presented in the narrative sections) are in Appendix A and Appendix B, respectively. Appendix C contains construction details for the wells in each regime that were sampled during CY 2006 by either the Y-12 GWPP or BJC. F

N /A

2007-09-01T23:59:59.000Z

499

Protocols for Monitoring Habitat Restoration Projects in the Lower Columbia River and Estuary  

SciTech Connect (OSTI)

Protocols for monitoring salmon habitat restoration projects are essential for the U.S. Army Corps of Engineers' environmental efforts in the Columbia River estuary. This manual provides state-of-the science data collection and analysis methods for landscape features, water quality, and fish species composition, among others.

Roegner, G. Curtis; Diefenderfer, Heida L.; Borde, Amy B.; Thom, Ronald M.; Dawley, Earl M.; Whiting, Allan H.; Zimmerman, Shon A.; Johnson, Gary E.

2008-04-25T23:59:59.000Z

500

Assessing effects of highway bridge deck runoff on near-by recieving waters in coastal margins using remote monitoring techniques  

E-Print Network [OSTI]

different pollutant loading by sampling the receiving water body (Clear Creek). The collected samples were analyzed for total suspended solids, toxic metals, and other relevant constituents of concerns. The results illustrated that the runoff from... the bridge deck iv exhibited low total suspended solids concentr ations (which were highest in the creek). However, other metal constituents like the zi nc and cooper concentration were high and above standards. The phosphate concentrations...

Nwaneshiudu, Oke

2005-02-17T23:59:59.000Z