1

New Water Booster Pump System Reduces Energy Consumption by 80...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Booster Pump System Reduces Energy Consumption by 80 Percent and Increases Reliability New Water Booster Pump System Reduces Energy Consumption by 80 Percent and Increases...

2

Small solar (thermal) water-pumping system  

SciTech Connect

A small solar (thermal) water pump phototype was tested. The pump works on an organic Rankine cycle using refrigerant R113. The design of the pump is described. Detailed temperature and pressure measurements of the working fluid for different operating conditions are performed. The behaviour of the cycle is analysed to get a clear picture of the thermodynamic process. Power-characteristic curves are obtained by a systematic variation of water temperature, pumping head and heat input. 10 refs., 13 figs., 2 tabs.

Spindler, K.; Hahne, E. [Universitaet Stuttgart (Germany)] [Universitaet Stuttgart (Germany); Chandwalker, K. [Stiletto Engineers, Hyderabad (India)] [Stiletto Engineers, Hyderabad (India)

1996-07-01T23:59:59.000Z

3

A DC Brushless PM Motor Driven Phptovoltaic Water Pumping System  

Science Journals Connector (OSTI)

Along with the worldwide more attention to environment and rapid development of photovoltaic industry, the PV water pumping system has rapidly developed, the economic ... estimated, up to now the operating PV water

Yu Shijie; Xie Lei; He Huiruo; Zhang Hualin…

2009-01-01T23:59:59.000Z

4

Split system CO2 heat pump water heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Split-system-CO2-heat-pump-water-heaters- Sign In About | Careers | Contact | Investors | bpa.gov Search Policy & Reporting Expand Policy & Reporting EE Sectors Expand EE...

5

Heat Pump Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Heaters Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales...

6

Performances of photovoltaic water pumping systems: a case study  

Science Journals Connector (OSTI)

This paper presents a mathematical motor-pump model for photovoltaic (PV) applications which allow us to contribute in the studies of PV pumping sizing. The modelled motor-pump characteristic is flow rate-power (Q, P). The model is established for centrifugal pump (CP) coupled to DC motor. The non-linear relation between flow rate and solar power has been obtained experimentally in a first step and then used for performance prediction. The model proposed enabled us to simulate the electric and hydraulic performances of CP pumps versus the total water heads for different PV array configuration. The experimental data are obtained with our pumping test facility. The performances are calculated using the measured meteorological data of different sites located in Saudi Arabia. The size of the PV array is varied to achieve the optimum performance of the proposed system.

M. Benghanem

2009-01-01T23:59:59.000Z

7

Study on Energy Efficiency Evaluation Method of Cooling Water System of Surface Water Source Heat Pump  

Science Journals Connector (OSTI)

Water source heat pump system is a green air-conditioning system which has high efficiency, energy saving, and environmental protection, but inappropriate design of the system type of water intake will impact on ...

Jibo Long; Siyi Huang

2014-01-01T23:59:59.000Z

8

Optimum Energy Management of a Photovoltaic Water Pumping System  

Science Journals Connector (OSTI)

This paper presents a new management of the energy of a photovoltaic water pumping installation composed of a battery, a water pump and a photovoltaic panel. The approach makes decision on the optimum connecti...

Souhir Sallem; Maher Chaabene; M. B. A. Kamoun

2009-01-01T23:59:59.000Z

9

Economic Analysis of a Waste Water Resource Heat Pump Air-Conditioning System in North China  

E-Print Network (OSTI)

This paper describes the situation of waste water resource in north China and the characteristics and styles of a waste water resource heat pump system, and analyzes the economic feasibility of a waste water resource heat pump air...

Chen, H.; Li, D.; Dai, X.

2006-01-01T23:59:59.000Z

10

Development and Application of Engineering-Scale Solar Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

An engineering-scale solar water heater system assisted by heat pump was developed based on ... . The subunits of modularized system include vacuum solar energy collectors, air source heat pump, ... Energy source...

Xiufeng Gao; Shiyu Feng; Wei Hu…

2009-01-01T23:59:59.000Z

11

Use of electromagnetic clutch water pumps in vehicle engine cooling systems to reduce fuel consumption  

Science Journals Connector (OSTI)

Abstract In general, when the internal combustion engine of a vehicle is started, its operationally connected cooling system provides excessive cooling, resulting in unnecessary energy consumption and excessive emission of exhaust gas. If the rotational speed of the engine is high, the excessive cooling causes the combustion efficiency to decrease. Therefore, better control of the operating temperature range of the engine through use of an active cooling system can achieve better fuel economy and reduction of exhaust gas emission. Effective control of the cooling system in accordance with the operating conditions of the engine can be realized by changing the mass flow rate of the coolant. In this study, we designed electromagnetic clutch water pumps that can control the coolant flow. We made two types of water pump: (1) a planetary gear (PG)-type water pump which can reduce the rotation speed of the water pump by 65%, compared with a pulley; and (2) an on/off-type water pump which can completely stop the rotation of the impeller. The performance evaluation of these pumps consisted of a warm-up test and the New European Driving Cycle (NEDC). Warm-up test results showed that the time required to achieve a temperature of approximately 80 °C with the PG water pump and the on/off water pump was improved by 7.3% and 24.7% respectively, compared with that of a conventional water pump. Based on the NEDC results, we determined that the fuel economy of the engine using the PG water pump and the on/off water pump was improved by 1.7% and 4.0% compared with the fuel economy when using the conventional water pump. The application of clutch water pumps is expected to contribute to the improvement of engine cooling system performance, because their effect in reducing the fuel consumption rate is similar to that of an electric water pump.

Yoon Hyuk Shin; Sung Chul Kim; Min Soo Kim

2013-01-01T23:59:59.000Z

12

Feasibility Analysis of Two Indirect Heat Pump Assisted Solar Domestic Hot Water Systems.  

E-Print Network (OSTI)

??This thesis is an analysis of the simulated performance of two indirect heat pump assisted solar domestic hot water (i-HPASDHW) systems compared to two base… (more)

Sterling, Scott Joseph

2011-01-01T23:59:59.000Z

13

Simulation and Validation of a Single Tank Heat Pump Assisted Solar Domestic Water Heating System.  

E-Print Network (OSTI)

??This thesis is a study of an indirect heat pump assisted solar domestic hot water (I-HPASDHW) system, where the investigated configuration is called the Dual… (more)

Wagar, William Robert

2013-01-01T23:59:59.000Z

14

The integration of water vane pump and hydraulic vane motor for a small desalination system  

Science Journals Connector (OSTI)

An integration of water vane pump and hydraulic vane motor was introduced in small reverse osmosis (RO) system, in which the hydraulic vane motor was used as energy recovery device. The hydraulic performance and energy consumption of one combination of pump and hydraulic motor were investigated under different operation conditions. This type of integration pump reduces energy cost and simplifies the system setup, thus it could be an alternative choice for small RO desalination system. Our results demonstrated that the improvement of volumetric efficiencies of the pump and the hydraulic motor was the main factor to increase the prototype pump performance.

Yong Lu; Yuanyang Zhao; Gaoxuan Bu; Pengcheng Shu

2011-01-01T23:59:59.000Z

15

Techno-Economic Evaluation of Renewable Energy Systems for Irrigation Water Pumping in India  

Science Journals Connector (OSTI)

An attempt to develop a simple framework for techno-economics evaluation of renewable energy (RE) systems for irrigation water pumping has been made. The unit cost of water delivered and unit cost of useful energy

Ishan Purohit; Pallav Purohit

2009-01-01T23:59:59.000Z

16

Economic Analysis and Comparison of Waste Water Resource Heat Pump Heating and Air-Conditioning System  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future, Vol.VIII-8-1 Economic Analysis and Comparison of Waste Water Resource Heat Pump Heating and Air-conditioning System Chunlei Zhang Suilin Wang Hongbing Chen...

Zhang, C.; Wang, S.; Chen, H.; Shi, Y.

2006-01-01T23:59:59.000Z

17

Heat Pump Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heaters Water Heaters Heat Pump Water Heaters May 4, 2012 - 5:21pm Addthis A diagram of a heat pump water heater. A diagram of a heat pump water heater. What does this mean for me? Heat pump water heaters can be two to three times more energy efficient than conventional electric storage water heaters. Heat pump water heaters work in locations that remain in the 40º-90ºF range year-round. Most homeowners who have heat pumps use them to heat and cool their homes. But a heat pump also can be used to heat water -- either as stand-alone water heating system, or as combination water heating and space conditioning system. How They Work Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. Therefore, they can be two to

18

Analysis of off-grid hybrid wind turbine/solar PV water pumping systems  

Science Journals Connector (OSTI)

While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic, wind-electric, diesel powered), few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) and solar photovoltaic (PV) array water pumping systems were analyzed individually and combined as a hybrid system. The objectives were to determine: (1) advantages or disadvantages of using a hybrid system over using a WT or a solar PV array alone; (2) if the WT or solar PV array interfered with the output of the other; and (3) which hybrid system was the most efficient for the location. The WT used in the analysis was rated at 900 W alternating current (AC). There were three different solar PV arrays analyzed, and they were rated at 320, 480, and 640 W direct current (DC). A rectifier converted the 3-phase variable voltage AC output from the WT to DC before combining it with the solar PV array DC output. The combined renewable energies powered a single helical pump. The independent variable used in the hybrid WT/PV array analysis was in units of W/m2. The peak pump efficiency of the hybrid systems at Bushland, TX occurred for the 900 W WT combined with the 640 W PV array. The peak pump efficiencies at a 75 m pumping depth of the hybrid systems were: 47% (WT/320 W PV array), 51% (WT/480 W PV array), and 55% (WT/640 W PV array). Interference occurred between the WT and the different PV arrays (likely due to voltage mismatch between WT and PV array), but the least interference occurred for the WT/320 W PV array. This hybrid system pumped 28% more water during the greatest water demand month than the WT and PV systems would have pumped individually. An additional controller with a buck/boost converter is discussed at end of paper for improvement of the hybrid WT/PV array water pumping system.

Brian D. Vick; Byron A. Neal

2012-01-01T23:59:59.000Z

19

Discussions on Disposal Forms of Auxiliary Heat Source in Surface Water Heat Pump System  

E-Print Network (OSTI)

This paper presents two common forms of auxiliary heat source in surface water heat pump system and puts forward the idea that the disposal forms affect operation cost. It deduces operation cost per hour of the two forms. With a project...

Qian, J.; Sun, D.; Li, X.; Li, G.

2006-01-01T23:59:59.000Z

20

Thermal Economic Analysis of an Underground Water Source Heat Pump System  

E-Print Network (OSTI)

The paper presents the thermal economic analysis of an underground water source heat pump system in a high school building based on usage per exergy cost as an evaluation standard, in which the black box model has been used and the cost...

Zhang, W.; Lin, B.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

SciTech Connect

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

Watzlaf, G.R.; Ackman, T.E.

2006-03-01T23:59:59.000Z

22

Assessment of a Solar Assisted Air Source and a Solar Assisted Water Source Heat Pump System in a Canadian Household  

Science Journals Connector (OSTI)

This paper presents an assessment of two solar assisted heat pump systems integrated into an air distribution system in three different 210 m2 single detached residential houses in Montreal, Canada. The housing types considered are a 1980's house, an energy efficient house and a “net zero ready” house. The advanced heat pump systems considered in the analysis focused on coupling solar energy on the evaporator side of an air source and water source heat pumps to improve performance compared to a standard air source heat pump and provide an alternative to a costly ground source heat pump system. The annual energy consumption and utility cost of the solar assisted heat pump systems were compared to a market available air source heat pump, a ground source heat pump system as well as the typical reference housing heating and cooling system. The results predicted that a solar assisted air source heat pump has a comparable capital cost to a ground source heat pump system in all housing types and the highest energy savings for a “net zero ready” house of 34% compared to the base case. The solar assisted water source heat pump did not yield interesting results, as the solar assisted air source heat pump demonstrated improved energy savings and lower capital costs in all housing types considered. Comparing the 20 year life cycle costs of the solar assisted heat pump systems to the base case, only in the 1980's housing archetype did the solar assisted air source heat pump system demonstrate a lower life cycle cost than the base case. A standard air source heat pump yielded the lowest life cycle cost in the 1980's and energy efficient house considered and the reference base case system had the lowest life cycle cost in the net zero ready house considered.

Martin Kegel; Justin Tamasauskas; Roberto Sunye; Antoine Langlois

2012-01-01T23:59:59.000Z

23

Work plan for vibration cable re-route and water flush system modifications for 107-AN mixer pump  

SciTech Connect

A mixer pump (75 horsepower Hazleton submersible) is to be installed in the central pump pit of Double-Shell Tank 241-AN-107 for the Caustic Addition Project. The mixer pump will be used as a platform to inject, mix, and entrain caustic with the waste, in order to bring the waste hydroxyl ion concentration into compliance with Tank Farm operating specifications. Testing of the mixer pump and caustic addition system revealed that the mixer pump`s vibration cable picks up electromagnetic interference from the motor power cable during variable speed operation of the pump. Also, it was noted that the mixer pump`s water flush system may not be as effective as desired. Ergo this work plan for improving the operation of these mixer pump subsystems. A new vibration cable shall be routed entirely outside the mixer pump support column pipe, up thru a new penetration in the pump mounting flange. The existing penetration in the side of the pipe is to be plugged. Increasing the distance between power and instrument cables may reduce or eliminate electromagnetic interference to the vibration monitor. The mixer pump water flush system shall be modified to allow pressure isolation of individual branches. A header is to be installed on the middle section of the support column. Each branch (there are three) shall contain a solenoid valve (normally open) to control flow into the branch. The solenoid cables shall be routed up thru three new penetrations in the pump mounting flange to a new electrical box mounted on the flange. The existing flush piping to the inlet screen will remain but the continuation of the flush piping to the pump discharge nozzles is to be removed and the tee plugged. New stainless steel tubing is to be run down to the pump discharge nozzles. Pressure isolation of individual branches will maximize the flush system`s effectiveness at blasting potential sediment clogs out of the pump discharge nozzles.

Leshikar, G.A.

1995-04-14T23:59:59.000Z

24

Water and Space Heating Heat Pumps  

E-Print Network (OSTI)

This paper discusses the design and operation of the Trane Weathertron III Heat Pump Water Heating System and includes a comparison of features and performance to other domestic water heating systems. Domestic water is generally provided through...

Kessler, A. F.

1985-01-01T23:59:59.000Z

25

Solar-assisted heat pump – A sustainable system for low-temperature water heating applications  

Science Journals Connector (OSTI)

Abstract Direct expansion solar assisted heat pump systems (DX-SAHP) have been widely used in many applications including water heating. In the DX-SAHP systems the solar collector and the heat pump evaporator are integrated into a single unit in order to transfer the solar energy to the refrigerant. The present work is aimed at studying the use of the DX-SAHP for low temperature water heating applications. The novel aspect of this paper involves a detailed long-term thermo-economic analysis of the energy conservation potential and economic viability of these systems. The thermal performance is simulated using a computer program that incorporates location dependent radiation, collector, economic, heat pump and load data. The economic analysis is performed using the life cycle cost (LCC) method. Results indicate that the DX-SAHP water heaters systems when compared to the conventional electrical water heaters are both economical as well as energy conserving. The analysis also reveals that the minimum value of the system life cycle cost is achieved at optimal values of the solar collector area as well as the compressor displacement capacity. Since the cost of SAHP system presents a barrier to mass scale commercialization, the results of the present study indicating that the SAHP life cycle cost can be minimized by optimizing the collector area would certainly be helpful in lowering, if not eliminating, the economic barrier to these systems. Also, at load temperatures higher than 70 °C, the performance of the single stage heat pump degrades to the extent that its cost and efficiency advantages over the electric only system are lost.

S.K. Chaturvedi; V.D. Gagrani; T.M. Abdel-Salam

2014-01-01T23:59:59.000Z

26

Analysis of a solar assisted heat pump system for indoor swimming pool water and space heating  

Science Journals Connector (OSTI)

Solar energy application is a good alternative to replace primary energy source especially for large-scale installations. Heat pumps are also effective means to reduce primary energy consumption. This paper describes a case study with a new design of solar assisted heat pump (SAHP) for indoor swimming pool space- and water-heating purposes. The system design procedure was first presented. The entire system was then modeled via the TRNSYS simulation environment and the energy performance was evaluated based on the winter time operation schedule. Economic analysis with a range of collector areas was also performed. The simulation results show that the overall system COP can reach 4.5, and the fractional factor of energy saving is 79% as compared to the conventional energy system. The economical payback period is less than 5 years.

T.T. Chow; Y. Bai; K.F. Fong; Z. Lin

2012-01-01T23:59:59.000Z

27

Annual Operating Characteristics of Solar Central Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

The solar central water heater (SCWH) could supply ... massive users effectively and reliably. A SCWH assisted by heat pump (SCWHP) was proposed...

Wei Hu; Zhaolin Gu; Shiyu Feng; Xiufeng Gao…

2009-01-01T23:59:59.000Z

28

Match Pumps to System Requirements  

SciTech Connect

BestPractices Program tip sheet discussing pumping system efficiency matching pumps to system requirements

Not Available

2005-10-01T23:59:59.000Z

29

Municipal water-based heat pump heating and/or cooling systems: Findings and recommendations. Final report  

SciTech Connect

The purpose of the present work was to determine if existing heat pump systems based on municipal water systems meet existing water quality standards, to analyze water that has passed through a heat pump or heat exchanger to determine if corrosion products can be detected, to determine residual chlorine levels in municipal waters on the inlet as well as the outlet side of such installations, to analyses for bacterial contaminants and/or regrowth due to the presence of a heat pump or heat exchanger, to develop and suggest criteria for system design and construction, to provide recommendations and specifications for material and fluid selection, and to develop model rules and regulations for the installation, operation, and monitoring of new and existing systems. In addition, the Washington State University (WSU) has evaluated availability of computer models that would allow for water system mapping, water quality modeling and system operation.

Bloomquist, R.G. [Washington, State Univ., Pullman, WA (United States); Wegman, S. [South Dakota Utilities Commission (United States)

1998-04-01T23:59:59.000Z

30

Water displacement mercury pump  

DOE Patents (OSTI)

A water displacement mercury pump has a fluid inlet conduit and diffuser, a valve, a pressure cannister, and a fluid outlet conduit. The valve has a valve head which seats in an opening in the cannister. The entire assembly is readily insertable into a process vessel which produces mercury as a product. As the mercury settles, it flows into the opening in the cannister displacing lighter material. When the valve is in a closed position, the pressure cannister is sealed except for the fluid inlet conduit and the fluid outlet conduit. Introduction of a lighter fluid into the cannister will act to displace a heavier fluid from the cannister via the fluid outlet conduit. The entire pump assembly penetrates only a top wall of the process vessel, and not the sides or the bottom wall of the process vessel. This insures a leak-proof environment and is especially suitable for processing of hazardous materials.

Nielsen, Marshall G. (Woodside, CA)

1985-01-01T23:59:59.000Z

31

New Water Booster Pump System Reduces Energy Consumption by 80 Percent and Increases Reliability  

Energy.gov (U.S. Department of Energy (DOE))

This case study outlines how General Motors (GM) developed a highly efficient pumping system for their Pontiac Operations Complex in Pontiac, Michigan. In short, GM was able to replace five original 60- to 100-hp pumps with three 15-hp pumps whose speed could be adjusted to meet plant requirements. As a result, the company reduced pumping system energy consumption by 80 percent (225,100 kWh per year), saving an annual $11,255 in pumping costs. With a capital investment of $44,966 in the energy efficiency portion of their new system, GM projected a simple payback of 4 years.

32

Fault Detection and Diagnosis for Brine to Water Heat Pump Systems.  

E-Print Network (OSTI)

?? This research project is part of a wider project called Smart Fault Detection and Diagnosis for HeatPump Systems currently under development by the Royal… (more)

Vecchio, Daniel

2014-01-01T23:59:59.000Z

33

Theoretical model for evaluation of variable frequency drive for cooling water pumps in sea water based once through condenser cooling water systems  

Science Journals Connector (OSTI)

In sea water based once through cooling water system for power plants, sea water is pumped through the condenser and the return hot water is let back to sea. The cooling water pumps (CWP) in power plants generally operate at constant speed, pumping variable quantities of water depending on the tide level in the sea. The variable flow causes variation in condenser back pressure resulting in changes in the turbine cycle heat rate. If the pump speed is controlled using a variable frequency drive (VFD) to maintain design flow irrespective of the tide level, the CWP power consumption can be reduced compared to the case with constant speed CWP. However, the turbine cycle heat rate benefit that could have accrued at tide levels above the pre defined level (for fixing the CWP head) with constant speed CWP would have to be sacrificed. This paper provides a theoretical model with a typical case study to establish viability of providing VFD for \\{CWPs\\} in power plants with sea water based once through condenser cooling water system.

R. Harish; E.E. Subhramanyan; R. Madhavan; S. Vidyanand

2010-01-01T23:59:59.000Z

34

Simulation and Modeling of a Constant Voltage Controller Based Solar Powered Water Pumping System  

Science Journals Connector (OSTI)

In this paper the performance of a squirrel cage induction motor driving a water-pump load is investigated. The induction motor is fed through a Photovoltaic (PV) array. The PV array and the drive is designed ...

Bhavnesh Kumar; Yogesh K. Chauhan…

2013-01-01T23:59:59.000Z

35

Absorption Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

36

Absorption Heat Pump Water Heater  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

37

Heat Pump Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump Water Heaters Heat Pump Water Heaters Standardized Templates for Reporting Test Results heatpumpwaterheaterv1.7.xlsx More Documents & Publications Tankless Gas Water...

38

Pumping System Assessment Tool  

Energy.gov (U.S. Department of Energy (DOE))

The Pumping System Assessment Tool (PSAT) is a free online software tool to help industrial users assess the efficiency of pumping system operations. PSAT uses achievable pump performance data from Hydraulic Institute standards and motor performance data from the MotorMaster+ database to calculate potential energy and associated cost savings. The tool also enables users to save and retrieve log files, default values, and system curves for sharing analyses with other users.

39

Wind pump systems  

Science Journals Connector (OSTI)

The application of wind mills for water pumping is of lesser importance ... it is useful to discuss this type of wind energy application in a wind energy book targeted at development and planning...

Prof. Dr.-Ing. Robert Gasch; Prof. Dr.-Ing. Jochen Twele

2012-01-01T23:59:59.000Z

40

Economical Analysis of a Groundwater Source Heat Pump with Water Thermal Storage System  

E-Print Network (OSTI)

The paper is based on a chilled and heat source for the building which has a total area of 140000m2 in the suburb of Beijing. By comparing the groundwater source heat pump of water thermal storage (GHPWTS) with a conventional chilled and heat source...

Zhou, Z.; Xu, W.; Li, J.; Zhao, J.; Niu, L.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Heat Pump Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pump Systems Pump Systems Heat Pump Systems May 16, 2013 - 5:33pm Addthis A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar. A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar. What does this mean for me? Heat pumps can supply heat, cooling, and hot water. Your climate and site will determine the type of heat pump most appropriate for your home. For climates with moderate heating and cooling needs, heat pumps offer an energy-efficient alternative to furnaces and air conditioners. Like your refrigerator, heat pumps use electricity to move heat from a cool space to a warm space, making the cool space cooler and the warm space warmer. During the heating season, heat pumps move heat from the cool outdoors into

42

Flathead Electric Cooperative Facility Geothermal Heat Pump System...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cooperative is uniquely positioned to provide marketing of ground source heat pump systems * 15' Static Water Level * Low Pumping Power * Reduced Installation Costs * Good...

43

Optimize Parallel Pumping Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pumping Systems This tip sheet describes how to optimize the performance of multiple pumps operating continuously as part of a parallel pumping system. PUMPING SYSTEMS TIP SHEET...

44

Analyzing the efficiency of a heat pump assisted drain water heat recovery system that uses a vertical inline heat exchanger  

Science Journals Connector (OSTI)

Abstract The purpose of the present study is to accumulate knowledge on how a drain water heat recovery system using a vertical inline heat exchanger and a heat pump performs under different drain water flow profile scenarios. Investigating how the intermittent behavior of the drain water influences the performance for this type of system is important because it gives insight on how the system will perform in a real life situation. The scenarios investigated are two 24 h drain water flow rate schedules and one shorter schedule representing a three minute shower. The results from the present paper add to the knowledge on how this type of heat recovery system performs in a setting similar to a multi-family building and how sizing influences the performance. The investigation shows that a heat recovery system of this type has the possibility to recover a large portion of the available heat if it has been sized to match the drain water profile. Sizing of the heat pump is important for the system performance; sizing of the storage tank is also important but not as critical.

Jörgen Wallin; Joachim Claesson

2014-01-01T23:59:59.000Z

45

Performance of an experimental ground-coupled heat pump system for heating, cooling and domestic hot-water operation  

Science Journals Connector (OSTI)

Abstract The ground-coupled heat pump (GCHP) system is a type of renewable energy technology providing space heating and cooling as well as domestic hot water. However, experimental studies on GCHP systems are still insufficient. This paper first presents an energy-operational optimisation device for a GCHP system involving insertion of a buffer tank between the heat pump unit and fan coil units and consumer supply using quantitative adjustment with a variable speed circulating pump. Then, the experimental measurements are used to test the performance of the GCHP system in different operating modes. The main performance parameters (energy efficiency and CO2 emissions) are obtained for one month of operation using both classical and optimised adjustment of the GCHP system, and a comparative analysis of these performances is performed. In addition, using TRNSYS (Transient Systems Simulation) software, two simulation models of thermal energy consumption in heating, cooling and domestic hot-water operation are developed. Finally, the simulations obtained using TRNSYS are analysed and compared to experimental data, resulting in good agreement and thus the simulation models are validated.

Calin Sebarchievici; Ioan Sarbu

2015-01-01T23:59:59.000Z

46

FS: heat pump water heaters | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Food Service » Install a heat pump Food Service » Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specificat Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specification The Food Service team developed a Commercial Heat Pump Water Heater Specification that can be used to reduce water heating energy by 70%. An older, electric resistance water heater (operated in a building with a hot water demand of 500 gallons a day) can cost more than $3,500 each year

47

Covered Product Category: Centrifugal Pumping System | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Centrifugal Pumping System Centrifugal Pumping System Covered Product Category: Centrifugal Pumping System October 7, 2013 - 11:25am Addthis FEMP provides acquisition guidance across a variety of product categories, including centrifugal pumping systems. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Buying Energy-Efficient Centrifugal Pumping Systems The most common applications for pumps at Federal facilities are for fresh water supply, hydronic heating and cooling systems, wastewater treatment, and drainage. For these applications, the most common type of pump is the centrifugal pump. Proper pump selection should consider both constant and variable flow and

48

Effectiveness of solar water-lift system with parabolic cylindrical solar energy collector and jet pump  

Science Journals Connector (OSTI)

Formulas are presented and a computer calculation program is implemented for determining the energy efficiency of a solar water-lift system module with a parabolic...

S. F. Ergashev

2007-03-01T23:59:59.000Z

49

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: Energyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

50

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

2001. Residential Heat Pump Water Heater (HPWH) Development2005. Residential Heat Pump Water Heaters: Energy Efficiencyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

51

Ground and Water Source Heat Pump Performance and Design for Southern Climates  

E-Print Network (OSTI)

Ground and water source heat pump systems have very attractive performance characteristics when properly designed and installed. These systems typically consist of a water-to-air or water-to-water heat pump linked to a closed loop vertical...

Kavanaugh, S.

1988-01-01T23:59:59.000Z

52

Flow pumping system for physiological waveforms  

E-Print Network (OSTI)

controlled pulsatile pump system for physiological ?owthe task of ?ow waveform generation between two pumps: agear pump generates the mean component and a piston pump

Tsai, William; Sava?, Ömer

2010-01-01T23:59:59.000Z

53

Dawdon Mine Water Heat Pump Trial  

E-Print Network (OSTI)

14-Dec-12 Dawdon Mine Water Heat Pump Trial #12;14 December 2012 2 Potential for Mine Water sourced heating Dawdon heat pump trial A demonstration project Contents #12;Friday, 14 December 2012 3 The UK salinity High Iron (removed by lime treatment) Offices , 8 rooms #12;Dawdon heat pump Warm mine water

Oak Ridge National Laboratory

54

Optimal Operation of Variable Speed Pumping System in China’s Eastern Route Project of S?to?N Water Diversion Project  

Science Journals Connector (OSTI)

A dynamic planning model for optimizing operation of variable speed pumping system aiming at minimum power consumption was proposed to achieve economic operation. The No. 4 Jiangdu Pumping Station a source pumping station in China’s Eastern Route of South?to?North Water Diversion Project is taken as a study case. Since the sump water level of Jiangdu Pumping Station is affected by the tide of Yangtze River the daily?average heads of the pumping system varies yearly from 3.8m to 7.8m and the tide level difference in one day up to 1.2m. Comparisons of operation electricity cost between optimized variable speed and fixed speed operations of pumping system were made. When the full load operation mode is adopted whether or not electricity prices in peak?valley periods are considered the benefits of variable speed operation cannot compensate the energy consumption of the VFD. And when the pumping system operates in part load and the peak?valley electricity prices are considered the pumping system should cease operation or lower its rotational speed in peak load hours since the electricity price are much higher and to the contrary the pumping system should raise its rotational speed in valley load hours to pump more water. The computed results show that if the pumping system operates in 80% or 60% loads the energy consumption cost of specified volume of water will save 14.01% and 26.69% averagely by means of optimal variable speed operation and the investment on VFD will be paid back in 2 or 3 years. However if the pumping system operates in 80% or 60% loads and the energy cost is calculated in non peak?valley electricity price the repayment will be lengthened up to 18 years. In China’s S?to?N Water Diversion Project when the market operation and peak?valley electricity prices are taken into effect to supply water and regulate water levels in regulation reservoirs as Hongzehu Lake Luomahu Lake etc. the economic operation of water?diversion pumping stations will be vital and the adoption of VFDs to achieve optimal operation may be a good choice.

Jilin Cheng; Lihua Zhang; Rentian Zhang; Yi Gong; Honggeng Zhu; Dongsheng Deng; Xuesong Feng; Jinxian Qiu

2010-01-01T23:59:59.000Z

55

salt-water pumped-storage hydroelectric plant  

Science Journals Connector (OSTI)

salt-water pumped-storage hydroelectric plant, saltwater pumped-storage hydroelectric station, seawater pumped-storage hydroelectric plant, seawater pumped-storage hydroelectric station ? Salzwasser-...

2014-08-01T23:59:59.000Z

56

Microfluidic system with integrated electroosmotic pumps, concentration gradient generator and fish cell line (RTgill-W1)--towards water toxicity  

E-Print Network (OSTI)

Microfluidic system with integrated electroosmotic pumps, concentration gradient generator and fish that incorporates electroosmotic pumps, a concentration gradient generator and a fish cell line (rainbow trout gill concentration distribution of toxicant in a cell test chamber, (2) an electroosmotic (EO) pump chip

Le Roy, Robert J.

57

Well-pump alignment system  

DOE Patents (OSTI)

An improved well-pump for geothermal wells, an alignment system for a well-pump, and to a method for aligning a rotor and stator within a well-pump are disclosed, wherein the well-pump has a whistle assembly formed at a bottom portion thereof, such that variations in the frequency of the whistle, indicating misalignment, may be monitored during pumping. 6 figs.

Drumheller, D.S.

1998-10-20T23:59:59.000Z

58

Report on New Pumping System Software on Pumping Instrumentation and Control Skids  

SciTech Connect

This report documents the details of the Programmable Logic Controller (PLC) and the Data Table Access Module (DTAM) logic developed for the new pumping system employed for saltwell pumping. The new system is planned first for pumping A-101 where Pumping Instrumentation and Control (PIC) skid ''F'' is located. The new pump requires a bump start under certain conditions that will be controlled by the PLC. The bump start is to ensure sufficient water to the pump bearing cavities. The PLC logic is required to control the shutdown of the injection pump that supplies the water to the saltwell pump bearing cavities. Allowance to start and stop the injection pump will be controlled by the PLC at the PIC skid. This report is written for PIC skid ''P'', but will apply to other PIC skids where the new pumping system is deployed. The logic will remain the same, but the ladder rung-numbers may change from skid to skid.

HORNER, T.M.

2001-04-19T23:59:59.000Z

59

Pump Systems Optimization: Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pump Systems Pump Systems Optimization: Energy Efficiency and Bottom-Line Savings Host this one-day course to help participants learn how to identify and reduce hidden operation and energy costs. Participants will: * Identify energy savings * Increase profitability * Increase reliability * Earn seven PDH credits Attendees of the "Pump Systems Optimization" one-day course will gain valuable new skills to help them improve centrifugal pump system efficiency to reduce energy and operating costs while earning seven professional development hour (PDH) credits from the Hydraulic Institute. Topics covered include:* * Why Efficient Pump Systems Are Important

60

Pumping System Assessment Tool Fact Sheet  

Energy.gov (U.S. Department of Energy (DOE))

This fact sheet describes how industrial plants can improve their pumping system efficiency using AMO's Pumping System Assessment Tool (PSAT).

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Pump Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Consumption by 80 Percent and Increases Reliability Optimizing Electric Motor Systems at a Corporate Campus Facility Optimized Pump Systems Save Coal Preparation Plant...

62

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network (OSTI)

tool for geothermal water loop heat pump systems, 9thInternational IEA Heat Pump Conference, Zürich, Switzerland,Performance of ground source heat pump system in a near-zero

Hong, Tainzhen

2010-01-01T23:59:59.000Z

63

CO2 Heat Pump Water Heater  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CO 2 Heat Pump Water Heater 2014 Building Technologies Office Peer Review Evaporator Kyle Gluesenkamp, gluesenkampk@ornl.gov Oak Ridge National Laboratory Project Summary Timeline:...

64

Fuel pumping system and method  

SciTech Connect

A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

Shafer, Scott F. (Morton, IL); Wang, Lifeng (Normal, IL) ,

2006-12-19T23:59:59.000Z

65

Fuel Pumping System And Method  

DOE Patents (OSTI)

A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

Shafer, Scott F. (Morton, IL); Wang, Lifeng (Normal, IL)

2005-12-13T23:59:59.000Z

66

Pumping System Assessment Tool Overview  

Energy.gov (U.S. Department of Energy (DOE))

This power point presentation provides an overview of AMO's pumping system assessment tool (PSAT) that is used during energy savings assessments at large industrial facilities.

67

MHK Technologies/Water Air Pump WAP | Open Energy Information  

Open Energy Info (EERE)

Pump WAP Pump WAP < MHK Technologies Jump to: navigation, search << Return to the MHK database homepage Water Air Pump WAP.jpg Technology Profile Primary Organization Shamil Ayntrazi Technology Resource Click here Wave Technology Type Click here Point Absorber - Submerged Technology Readiness Level Click here TRL 5 6 System Integration and Technology Laboratory Demonstration Technology Description The Water Air Pump WAP uses a partially submerged funnel shaped air pump to compress air collect it in a piping network and feed it to an air turbine Mooring Configuration Gravity base installed at the sea bed Technology Dimensions Device Testing Date Submitted 11:50.0 << Return to the MHK database homepage Retrieved from "http://en.openei.org/w/index.php?title=MHK_Technologies/Water_Air_Pump_WAP&oldid=681697"

68

To cite this version : Roboam, Xavier and Sareni, Bruno and Nguyen, Duc Trung and Belhadj, Jamel. Optimal system management of a water pumping and  

E-Print Network (OSTI)

sources. (2012). In: 8th Power Plant and Power System Control Conference, 02-05 Sep 2012, Toulouse, France-19Dec2013 Author manuscript, published in "8th Power Plant and Power System Control Conference, Toulouse for a water pumping and desalination process which would be powered by a hybrid (solar PV & wind) renewable

Paris-Sud XI, Université de

69

Optimization of Solar Pump System Without Electrical Storage  

Science Journals Connector (OSTI)

The purpose of this work is to develop a simple pumping system which needs no maintenance, optimizes the conversion efficiency of the peak panel output with respect to the amount of water pumped daily, taking int...

U. Cirri; M. M. Maltagliati

1981-01-01T23:59:59.000Z

70

Improving pumping system efficiency at coal plants  

SciTech Connect

The industry must employ ultramodern technologies when building or upgrading power plant pumping systems thereby using fuels more efficiently. The article discusses the uses and efficiencies of positive displacement pumps, centrifugal pumps and multiple screw pumps. 1 ref., 4 figs.

Livoti, W.C.; McCandless, S.; Poltorak, R. [Baldor Electric Co. (United States)

2009-03-15T23:59:59.000Z

71

CO2 Heat Pump Water Heater | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heater CO2 Heat Pump Water Heater CO2 Heat Pump Water Heater Prototype
Credit: Oak Ridge National Lab CO2 Heat Pump Water Heater Prototype Credit: Oak Ridge National Lab...

72

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: EnergyA Specification for Residential Heat Pump Water Heaters

Franco, Victor

2011-01-01T23:59:59.000Z

73

The pumps deliver this water to users in the Bay Area, the southern Central Valley, and Southern California. This system  

E-Print Network (OSTI)

The pumps deliver this water to users in the Bay Area, the southern Central Valley, and Southern Delta is part of the largest estu- ary on the West Coast, providing a home to a diverse array of fish in the Central Valley. This important region is now in a serious, long-term crisis. Many of the Delta's native

Pasternack, Gregory B.

74

Absorption Heat Pump Water Heater - 2013 Peer Review | Department...  

Energy Savers (EERE)

Absorption Heat Pump Water Heater - 2013 Peer Review Absorption Heat Pump Water Heater - 2013 Peer Review Emerging Technologies Project for the 2013 Building Technologies Office's...

75

Residential Absorption Heat Pump Water Heater | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heat Pump Water Heater Residential Absorption Heat Pump Water Heater Photo credit: Oak Ridge National Lab Photo credit: Oak Ridge National Lab Diagram of absorption heat...

76

Covered Product Category: Residential Heat Pump Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Heat Pump Water Heaters Covered Product Category: Residential Heat Pump Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance and...

77

Match Pumps to System Requirements | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Match Pumps to System Requirements Match Pumps to System Requirements This tip sheet describes how to correct imbalanced pumping systems and improve system efficiency. PUMPING...

78

Heat Pump Water Heaters Demonstration Project  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump Water Heaters Heat Pump Water Heaters Demonstration Project Building America Stakeholder Meeting Ron Domitrovic Ammi Amarnath 3/1/2012 Austin, TX 2 © 2011 Electric Power Research Institute, Inc. All rights reserved. HPWH Field Demonstration: Research Objectives * Assess heat pump water heater technology by measuring efficiency. * Provide credible data on the performance and reliability of heat pump water heaters. * Assess user satisfaction in a residential setting. 3 © 2011 Electric Power Research Institute, Inc. All rights reserved. Demonstration Host Utilities Target: 40 Units per Utility Installed and Potential Sites by Climate Zone Source: Department of Energy (DOE), Building America climate regions 4 © 2011 Electric Power Research Institute, Inc. All rights reserved. Installation Locations-Southern Company Region

79

Ag & Water Pump | OpenEI  

Open Energy Info (EERE)

Ag & Water Pump Ag & Water Pump Dataset Summary Description Natural gas consumption data from the California Energy Commission by planning area for Commercial, Residential, Ag & Water Pump, Streetlight, Industry, Mining & Construction and Total Usage. Source California Energy Commission Date Released Unknown Date Updated Unknown Keywords Ag & Water Pump annual energy consumption Commercial Energy Consumption Industry Residential Streetlight Data text/csv icon Natural Gas Consumption by Planning Area (csv, 12.6 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period 1990-2009 License License Other or unspecified, see optional comment below Comment http://www.energy.ca.gov/conditions.html Rate this dataset Usefulness of the metadata

80

IEA Heat Pump Conference 2011, 16 -19 May 2011, Tokyo, Japan DYNAMIC MODELING OF AN AIR SOURCE HEAT PUMP WATER  

E-Print Network (OSTI)

. Compared to those water heaters, heat pump water heating systems can supply much more heat just with the same amount of electric input used for electric water heaters. The ASHPWH absorbs heat from the ambient- 1 - 10th IEA Heat Pump Conference 2011, 16 - 19 May 2011, Tokyo, Japan DYNAMIC MODELING OF AN AIR

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Heat Pump Water Heater Performance in  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

searc searc e er tra A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida searc e er tra Heat Pump Water Heater Performance in Laboratory House Building America Technical Update 2013 ACI National Home Performance Conference April 29- 30 , 2013 Carlos J. Colon carlos@fsec.ucf.edu A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida Hot Water Systems (HWS) Laboratory FSEC Grounds, Florida (east coast) 2009 -Present (Currently fourth testing rotation) FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida

82

Test for Pumping System Efficiency | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Test for Pumping System Efficiency Test for Pumping System Efficiency This tip sheet discusses important considerations when conducting pumping system efficiency tests. PUMPING...

83

Photovoltaic Pumping Systems A Comparison of Two Concepts  

E-Print Network (OSTI)

Photovoltaic Pumping Systems A Comparison of Two Concepts Hans Bloos, Markus Genthner, Detlev of Oldenburg two different concepts of photovoltaic pumping subsystems available on the market were Photovoltaic pumping (PVP) has established itself as a water lifting technique for remote areas in sun

Heinemann, Detlev

84

Process Cooling Pumping Systems Analysis  

E-Print Network (OSTI)

their calculated design conditions. As observed, each system was running +1 pump more than required to meet the requirement. System 1 was overpumped by 25%, or 1100 GPM, and System 2 was overpumped by 37%, or 1850 GPM. Both systems may provide adequate heat...

Sherman, C.

2008-01-01T23:59:59.000Z

85

Pump control system for windmills  

DOE Patents (OSTI)

A windmill control system having lever means, for varying length of stroke of the pump piston, and a control means, responsive to the velocity of the wind to operate the lever means to vary the length of stroke and hence the effective displacement of the pump in accordance with available wind energy, with the control means having a sensing member separate from the windmill disposed in the wind and displaceable thereby in accordance with wind velocity.

Avery, Don E. (45-437 Akimala St., Honolulu, HI 96744)

1983-01-01T23:59:59.000Z

86

Pump Systems Matter Mission and Vision:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pump Systems Matter Mission and Vision: Pump Systems Matter Mission and Vision: Pump Systems Matter(tm) (PSM) places a primary focus on pump systems education and outreach and addresses energy savings and total cost of pump ownership. Vision: Pump Systems Matter initiative assists North American pump users gain a more competitive business advantage through strategic, broad-based energy management and pump system performance optimization. Mission: To provide the marketplace with tools and collaborative opportunities to integrate pump system performance optimization and efficient energy management practices into normal business operations. Essential Elements: * Build awareness of the benefits of systems optimization and pump system life cycle cost at the management, production and technical levels of companies throughout the supply chain.

87

Refrigerant charge management in a heat pump water heater  

DOE Patents (OSTI)

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

Chen, Jie; Hampton, Justin W.

2014-06-24T23:59:59.000Z

88

Heat Pump System Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump System Basics Heat Pump System Basics Heat Pump System Basics August 19, 2013 - 11:02am Addthis Like a refrigerator, heat pumps use electricity to move heat from a cool space into a warm space, making the cool space cooler and the warm space warmer. Because they move heat rather than generate heat, heat pumps can provide up to four times the amount of energy they consume. Air-Source Heat Pump Transfers heat between the inside of a building and the outside air. Ductless Mini-Split Heat Pump Ductless versions of air-source heat pumps. Absorption Heat Pump Uses heat as its energy source. Geothermal Heat Pumps Use the constant temperature of the earth as the exchange medium instead of the outside air temperature. Addthis Related Articles A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar.

89

Irrigation Pump Testing  

NLE Websites -- All DOE Office Websites (Extended Search)

Toolkit The Benefits of Irrigation Pump Testing & System Analysis Almost all irrigation pumps use an "impeller" to provide the centrifugal force to distribute water. Pumps with...

90

Heat Pump Water Heating Modeling in EnergyPlus  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump Water Heater Modeling Heat Pump Water Heater Modeling in EnergyPlus Building America Residential Energy Efficiency Stakeholder Meeting Eric Wilson Craig Christensen March 1, 2012 2 Modeling Issues Results Motivation Heat Pump Water Heater Modeling... 3 Gap: Existing analysis tools cannot accurately model HPWHs with reasonable runtime. 4 What have we achieved so far? Laboratory Evaluations 14 x Field Monitoring 5 Closing the Gap Laboratory Evaluations 6 sec timestep hourly timestep 14 x Field Monitoring CARB 6 Why is modeling important? * Performance varies: Can't just use EF * System interaction o HPWH affects building heating and cooling o Space conditions affect HPWH performance 7 Modeling Goals * Manage Risks o Accuracy o Run time o Occupant satisfaction * Flexibility to explore the effects of:

91

Heat Pump Water Heater using Solid-State Energy Converters |...  

Energy Savers (EERE)

Heat Pump Water Heater using Solid-State Energy Converters Heat Pump Water Heater using Solid-State Energy Converters Sheetak will work on developing a full scale prototype of its...

92

Experimental study on roll-bond collector/evaporator with optimized-channel used in direct expansion solar assisted heat pump water heating system  

Science Journals Connector (OSTI)

Abstract In this investigation, a direct expansion solar assisted heat pump (DX-SAHP) water heating system using an optimized-channel roll-bond collector/evaporator was designed, fabricated and tested. Optimized fractal T-shape and honeycomb shaped channel patterns were adopted to improve the thermal performance of the roll-bond panel, which acts as both the evaporator for the heat pump system and the collector for solar thermal utilization. The performance of the studied water heating system using the south-faced, wall-mounted roll-bond panel with the new composite channel patterns was investigated experimentally. Results show that, under the experimental conditions, the roll-bond panel with optimized channel pattern shows better thermal properties, and the performance the DX-SAHP system is significantly enhanced by using the roll-bond panel with optimized channel pattern. Compared to the conventional parallel channel pattern, fractal T-shaped channel pattern enhanced COP of the system by 14.6%, and heating capacity by 17.3%. And the honeycomb shaped channel pattern further enhanced COP and heating capacity of the system by 5.9% and 6.2%.

Xiaolin Sun; Jingyi Wu; Yanjun Dai; Ruzhu Wang

2014-01-01T23:59:59.000Z

93

NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet)  

SciTech Connect

NREL evaluates energy savings potential of heat pump water heaters in homes throughout all U.S. climate zones.

Not Available

2012-02-01T23:59:59.000Z

94

Applications Tests of Commercial Heat Pump Water Heaters  

E-Print Network (OSTI)

Field application tests have been conducted on three 4 to 6-ton commercial heat pump water heater systems in a restaurant, a coin-operated laundry, and an office building cafeteria in Atlanta. The units provide space cooling while rejecting heat...

Oshinski, J. N..; Abrams, D. W.

1987-01-01T23:59:59.000Z

95

Heat pump system  

DOE Patents (OSTI)

An air heating and cooling system for a building includes an expansion type refrigeration circuit and a vapor power circuit. The refrigeration circuit includes two heat exchangers, one of which is communicated with a source of indoor air from the building and the other of which is communicated with a source of air from outside the building. The vapor power circuit includes two heat exchangers, one of which is disposed in series air flow relationship with the indoor refrigeration circuit heat exchanger and the other of which is disposed in series air flow relationship with the outdoor refrigeration circuit heat exchanger. Fans powered by electricity generated by a vapor power circuit alternator circulate indoor air through the two indoor heat exchangers and circulate outside air through the two outdoor heat exchangers. The system is assembled as a single roof top unit, with a vapor power generator and turbine and compressor thermally insulated from the heat exchangers, and with the indoor heat exchangers thermally insulated from the outdoor heat exchangers.

Swenson, Paul F. (Shaker Heights, OH); Moore, Paul B. (Fedhaven, FL)

1983-01-01T23:59:59.000Z

96

Overview of Pump Systems Matter | Department of Energy  

Energy Savers (EERE)

Pump Systems Matter Pump Systems Matter (PSM) is a non-profit (501(c) 3) educational foundation, established to educate the marketplace and promote pumping systems energy...

97

Pump Systems Matter Mission and Vision | Department of Energy  

Energy Savers (EERE)

issionofPumpSystemsMatter.pdf More Documents & Publications Overview of Pump Systems Matter Hydraulic Institute Member Benefits Course Overview Pump Systems Matter Optimization...

98

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Water Heater: up to $275 Heat Pump Replacement: $400 Provider Rock Hill Utilities Through the SmartChoice program, Rock Hill Utilities offers rebates for water heater and heat pump replacements. Information on financing for heat pumps can also be found on the web site listed above. If both the water heater and heat pump are purchased then the customer may qualify for the Great Rate program. The Great Rate program will add a 25% discount to a

99

PARAMETER ESTIMATION BASED MODELS OF WATER SOURCE HEAT PUMPS  

E-Print Network (OSTI)

PARAMETER ESTIMATION BASED MODELS OF WATER SOURCE HEAT PUMPS By HUI JIN Bachelor of Science validation of the water-to-air heat pump model. It's hard to find any words to express the thanks to my BASED MODELS OF WATER SLOURCE HEAT PUMPS Thesis Approved: Thesis Adviser Dean of the Graduate College ii

100

Screw-fed pump system  

DOE Patents (OSTI)

A pump system includes a pump that includes a first belt and a second belt that are spaced apart from each other to provide generally straight sides of a passage there between. There is an inlet at one end of the passage and an outlet at an opposite end of the passage, with a passage length that extends between the inlet and the outlet. The passage defines a gap distance in a width direction between the straight sides at the passage inlet. A hopper includes an interior space that terminates at a mouth at the passage inlet. At least one screw is located within the interior space of the hopper and includes a screw diameter in the width direction that is less than or equal to the gap distance.

Sprouse, Kenneth M

2014-11-25T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

ROCKY MOUNTAIN OILFIELD TESTING CENTER Texaco Dual Action Pumping System  

NLE Websites -- All DOE Office Websites (Extended Search)

Texaco Dual Action Pumping System Texaco Dual Action Pumping System PROJECT TEST RESULTS March 16, 1998 Michael R. Tyler Project Manager Abstract The Texaco Dual Action Pumping System (DAPS) is designed to separate water from the oil in the casing-tubing annulas and inject most of the water into a lower formation while lifting the oil and remaining water to the surface. As oil production declines in a well the water production can increase. The lifting cost can be reduced per barrel of oil if less water is brought to the surface and processed. The DAPS was installed in a well that had been producing four (4) barrels of oil per day (bopd) and 46 barrels of water per day (bwpd), from the zone that became the injection zone. The well was recompleted in a shallower zone that was expected to yield an excessive quantity of

102

DHV water pumping optimization Simon van Mourik1  

E-Print Network (OSTI)

Chapter 6 DHV water pumping optimization Simon van Mourik1 Joris Bierkens2 Hans Stigter1 Martijn for optimizing a drinking water network over a horizon of 48 hours, given variable water demands, energy prices and constraints on the pumping strategy and water levels in the reservoirs. Both the dynamic model and goal

Rottschäfer, Vivi

103

MHK Technologies/Wave Water Pump WWP | Open Energy Information  

Open Energy Info (EERE)

Pump WWP Pump WWP < MHK Technologies Jump to: navigation, search << Return to the MHK database homepage Wave Water Pump WWP.gif Technology Profile Primary Organization Renewable Energy Wave Pumps Technology Resource Click here Wave Technology Description The Water Wave Pump WWP is a point absorber that uses a submerged water pump to lift a small quantity of water to a higher head collect it in a piping network and feed it to a hydro turbine to produce power Mooring Configuration Gravity base installed at the sea bed Optimum Marine/Riverline Conditions The REWP can pump water to a hgih head fro waves ranging between 1 2 meters to waves in excess of 4 meters high It self adjusts to varyilng sea levels and wave hights It resists storms safe to navigation as red floats are clearly seen during the day and red flashing lights during the night It does not disturb marine life or shore line scenic view

104

Carbon Dioxide Heat Pump Water Heater Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Research Project Carbon Dioxide Heat Pump Water Heater Research Project The U.S. Department of Energy is currently conducting research into carbon dioxide (CO2) heat pump water heaters. This project will employ innovative techniques to adapt water heating technology to meet U.S. market requirements, including specifications, cost, and performance targets. Carbon dioxide is a refrigerant with a global warming potential (GWP) of 1. The CO2 heat pump water heater research seeks to develop an improved life cycle climate performance compared to conventional refrigerants. For example, R134a, another type of refrigerant, has a GWP of 1,300. Project Description This project seeks to develop a CO2-based heat pump water heater (HPWH)

105

VAPOR COMPRESSION HEAT PUMP SYSTEM FIELD TESTS AT THE TECH COMPLEX  

E-Print Network (OSTI)

323 CHAPTER 17 VAPOR COMPRESSION HEAT PUMP SYSTEM FIELD TESTS AT THE TECH COMPLEX \\B E Van D for several novel and conventional heat pump systems for space conditioning and water heating. Systems tested include the Annual Cycle Energy System (ACES), solar assisted heat pumps (SAHP) both parallel and series

Oak Ridge National Laboratory

106

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet)  

SciTech Connect

A new simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes.

Hudon, K.

2012-05-01T23:59:59.000Z

107

Investigation of induction motors of pumps for water wells  

Science Journals Connector (OSTI)

A digital three-phase model of a submersible induction motor drive for pumps of water wells that is convenient for modeling on...

R. I. Mustafaev; R. A. Saidov

2011-04-01T23:59:59.000Z

108

Sustainable Energy Source for Water Pumping at Puttalam Salt Limited.  

E-Print Network (OSTI)

?? The cost of grid based electrical and diesel sea water pumping to salt fields is one of the major cost components out of the… (more)

Kamaldeen, Mohammed Rizwan

2014-01-01T23:59:59.000Z

109

PERFORMANCE MODEL FOR MULTIBLADED WATER-PUMPING WIND-MILLS  

Science Journals Connector (OSTI)

ABSTRACT The steady and the dynamic equilibrium of a multibladed water-pumping wind-mill has been studied under the assumption of a simple model. Good agreement has been found between theoretical and experimental results. KEYWORDS Wind energy; water-pumping wind-mills; wind-mill design; wind-mill test; performance optimization.

R. Pallabazzer

1986-01-01T23:59:59.000Z

110

Method and system for small scale pumping  

DOE Patents (OSTI)

The present invention relates generally to the field of small scale pumping and, more specifically, to a method and system for very small scale pumping media through microtubes. One preferred embodiment of the invention generally comprises: method for small scale pumping, comprising the following steps: providing one or more media; providing one or more microtubes, the one or more tubes having a first end and a second end, wherein said first end of one or more tubes is in contact with the media; and creating surface waves on the tubes, wherein at least a portion of the media is pumped through the tube.

Insepov, Zeke (Darien, IL); Hassanein, Ahmed (Bolingbrook, IL)

2010-01-26T23:59:59.000Z

111

Renewable energy and sustainable developments in Egypt: photovoltaic water pumping in remote areas  

Science Journals Connector (OSTI)

This paper considers the economics of using photovoltaic (PV) technology for developing remote areas. “East Owienat” in Upper Egypt is the chosen region: there, the feasibility of using PV systems for the pumping of ground water in comparison with using diesel units, taking into consideration the different parameters affecting the costs and the present value of both systems, is considered. The study proved that PV-battery systems can be used efficiently for water pumping at East Owienat: the cost of the water unit pumped by PV systems is much less than that pumped using diesel systems, and the water cost is more sensitive to PV cells’ prices than their life-time periods.

Elham Mahmoud; Hoseen el Nather

2003-01-01T23:59:59.000Z

112

Short communication Optimization of hybrid ground coupled and air source heat pump systems  

E-Print Network (OSTI)

Short communication Optimization of hybrid ­ ground coupled and air source ­ heat pump systems 2008 Accepted 14 January 2010 Available online 28 January 2010 Keywords: Ground coupled heat pump Air to water heat pump Thermal storage device Hybrid HVAC system Energy efficiency Numerical simulation a b

Fernández de Córdoba, Pedro

113

Hanford's 200 West Pump and Treat System Garners Worldwide Attention |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

200 West Pump and Treat System Garners Worldwide 200 West Pump and Treat System Garners Worldwide Attention Hanford's 200 West Pump and Treat System Garners Worldwide Attention August 27, 2013 - 12:00pm Addthis The award recognized CH2M HILL for its excellence in the international water industry. CH2M HILL’s Water Business Group's International Client Sector Director Peter Nicol accepted the award from Global Water Awards Speaker and former Mexican President Vicente Fox. The award recognized CH2M HILL for its excellence in the international water industry. CH2M HILL's Water Business Group's International Client Sector Director Peter Nicol accepted the award from Global Water Awards Speaker and former Mexican President Vicente Fox. The 200 West Pump and Treat System design and construction teams utilized energy efficient and sustainable design elements, including recycled steal. This photo shows the system’s processing equipment. Approximately 539 tons, or 5 percent, of the steel used in construction was recycled.

114

Multi-Source Hydronic Heat Pump System Performance Test Bed  

E-Print Network (OSTI)

pump unit) with a central chilled water storage tank. The MSHHP system uses significantly less energy than a conventional HVAC system, and lowers peak demand by shifting required electrical energy consumption to lower-cost, off-peak and mid-peak rates...

Meckler, M.

1984-01-01T23:59:59.000Z

115

Reducing booster-pump-induced contaminant intrusion in Indian water systems with a self-actuated, back-pressure regulating valve  

E-Print Network (OSTI)

Intermittently-operated water systems struggle to equitably and effectively distribute clean water to customers. One common customer response to intermittency is to supplement the water system's pressure by using a household, ...

Taylor, David Donald James

2014-01-01T23:59:59.000Z

116

Flathead Electric Cooperative Facility Geothermal Heat Pump System...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade Project Will Take Advantage of...

117

Optimized Pump Systems Save Coal Preparation Plant Money and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Optimized Pump Systems Save Coal Preparation Plant Money and Energy Optimized Pump Systems Save Coal Preparation Plant Money and Energy This case study describes how Peabody...

118

A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.  

E-Print Network (OSTI)

??Heat pump water heaters are a promising technology to reduce energy use and greenhouse gas emissions. A key component is the water heating heat exchanger.… (more)

Weerawoot, Arunwattana

2010-01-01T23:59:59.000Z

119

Submersible pumping system with heat transfer mechanism  

DOE Patents (OSTI)

A submersible pumping system for downhole use in extracting fluids containing hydrocarbons from a well. In one embodiment, the pumping system comprises a rotary induction motor, a motor casing, one or more pump stages, and a cooling system. The rotary induction motor rotates a shaft about a longitudinal axis of rotation. The motor casing houses the rotary induction motor such that the rotary induction motor is held in fluid isolation from the fluid being extracted. The pump stages are attached to the shaft outside of the motor casing, and are configured to impart fluid being extracted from the well with an increased pressure. The cooling system is disposed at least partially within the motor casing, and transfers heat generated by operation of the rotary induction motor out of the motor casing.

Hunt, Daniel Francis Alan; Prenger, F. Coyne; Hill, Dallas D; Jankowski, Todd Andrew

2014-04-15T23:59:59.000Z

120

Mass spectrometer vacuum housing and pumping system  

DOE Patents (OSTI)

A vacuum housing and pumping system for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof.

Coutts, Gerald W. (Livermore, CA); Bushman, John F. (Oakley, CA); Alger, Terry W. (Tracy, CA)

1996-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Mass spectrometer vacuum housing and pumping system  

DOE Patents (OSTI)

A vacuum housing and pumping system is described for a portable gas chromatograph/mass spectrometer (GC/MS). The vacuum housing section of the system has minimum weight for portability while designed and constructed to utilize metal gasket sealed stainless steel to be compatible with high vacuum operation. The vacuum pumping section of the system consists of a sorption (getter) pump to remove atmospheric leakage and outgassing contaminants as well as the gas chromatograph carrier gas (hydrogen) and an ion pump to remove the argon from atmospheric leaks. The overall GC/MS system has broad application to contaminants, hazardous materials, illegal drugs, pollution monitoring, etc., as well as for use by chemical weapon treaty verification teams, due to the light weight and portability thereof. 7 figs.

Coutts, G.W.; Bushman, J.F.; Alger, T.W.

1996-07-23T23:59:59.000Z

122

In search for sustainable globally cost-effective energy efficient building solar system – Heat recovery assisted building integrated PV powered heat pump for air-conditioning, water heating and water saving  

Science Journals Connector (OSTI)

Abstract Obtained as a research result of conducted project, this paper presents an innovative, energy efficient multipurpose system for a sustainable globally cost-effective building's solar energy use and developed methodology for its dynamic analysis and optimization. The initial research and development goal was to create a cost-effective technical solution for replacing fossil fuel and electricity with solar energy for water heating for different purposes (for pools, sanitary water, washing) in one SPA. After successful realization of the initial goal, the study was proceeded and as a result, the created advanced system has been enriched with AC performance. The study success was based on understanding and combined measurements and by BPS made predictions of AC loads and solar radiation dynamics as well as on the determination of the synergetic relations between all relevant quantities. Further, by the performed BPS dynamic simulations for geographically spread buildings locations, it has been shown that the final result of the conducted scientific engineering R&D work has been the created system of confirmed prestigious to the sustainability relevant performance – globally cost-effective building integrated photovoltaic powered heat pump (HP), assisted by waste water heat recovery, for solar AC, water heating and saving.

Marija S. Todorovic; Jeong Tai Kim

2014-01-01T23:59:59.000Z

123

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of chilled water pumps  

E-Print Network (OSTI)

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of HVAC equipment using variable speed drive (VSD) is an Energy Conservation Opportunity (ECO) which can

Paris-Sud XI, Université de

124

Purge water management system  

DOE Patents (OSTI)

A purge water management system is described for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

Cardoso-Neto, J.E.; Williams, D.W.

1995-01-01T23:59:59.000Z

125

One Machine for Heating Cooling & Domestic Hot Water: Multi-Function Heat Pumps to Enable Zero Net Energy Homes  

E-Print Network (OSTI)

advances to commercialize stand-alone electric heat-pump storage hot water heaters. These systems offer design uses multiple systems and fuels to provide thermal services, the emerging generation of heat to experience this change as air-source heat-pump water heaters deliver obvious energy savings over electric

California at Davis, University of

126

Critical Question #8: When are Heat Pump Water Heaters the Best Solution? |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8: When are Heat Pump Water Heaters the Best 8: When are Heat Pump Water Heaters the Best Solution? Critical Question #8: When are Heat Pump Water Heaters the Best Solution? What do we know about actual performance compared to promised performance? What is the best way to manage the space conditioning impacts on a home? Is there an easy decision tree for deciding if this is the best solution for a particular home (Climate? Utility prices? Accessibility? Physical space constraints? Workforce?)? cq8_residential_hpwh_costs_maguire.pdf cq8_hpwh_performance_colon.pdf cq8_hpwhs_multifamily_weitzel.pdf More Documents & Publications Track A - Energy Systems Innovations Illustrative Calculation of Economics for Heat Pump and "Grid-Enabled" Water Heaters Standing Technical Committee Working Sessions

127

Pump Life Cycle Costs: A Guide to LCC Analysis for Pumping Systems- Executive Summary  

Energy.gov (U.S. Department of Energy (DOE))

This brochure is a management tool that can help companies minimize waste and maximize energy efficiency for pumping systems.

128

Selection of fluids for tritium pumping systems  

SciTech Connect

The degradation characteristics of three types of vacuum pump fluids, polyphenyl ethers, perfluoropolyethers and hydrocarbon oils were reviewed. Fluid selection proved to be a critical factor in the long-term performance of tritium pumping systems and subsequent tritium recovery operations. Thermal degradation and tritium radiolysis of pump fluids produce contaminants which can damage equipment and interfere with tritium recovery operations. General characteristics of these fluids are as follows: polyphenyl ether has outstanding radiation resistance, is very stable under normal diffusion pump conditions, but breaks down in the presence of oxygen at anticipated operating temperatures. Perfluoropolyether fluids are very stable and do not react chemically with most gases. Thermal and mechanical degradation products are inert, but the radiolysis products are very corrosive. Most of the degradation products of hydrogen oils are volatile and the principal radiolysis product is methane. Our studies show that polyphenyl ethers and hydrocarbon oils are the preferred fluids for use in tritium pumping systems. No corrosive materials are formed and most of the degradation products can be removed with suitable filter systems.

Chastagner, P

1984-02-01T23:59:59.000Z

129

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network (OSTI)

as other types of air source heat pumps, VRF systems needconventional packaged air source heat pumps. Typical GSHPis basically an air source heat pump), especially when the

Hong, Tainzhen

2010-01-01T23:59:59.000Z

130

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect

This report discusses how a significant opportunity for energy savings is domestic hot water heating, where an emerging technology has recently arrived in the U.S. market: the residential integrated heat pump water heater. A laboratory evaluation is presented of the five integrated HPWHs available in the U.S. today.

Sparn, B.; Hudon, K.; Christensen, D.

2011-09-01T23:59:59.000Z

131

Chemical heat pump and chemical energy storage system  

DOE Patents (OSTI)

A chemical heat pump and storage system employs sulfuric acid and water. In one form, the system includes a generator and condenser, an evaporator and absorber, aqueous acid solution storage and water storage. During a charging cycle, heat is provided to the generator from a heat source to concentrate the acid solution while heat is removed from the condenser to condense the water vapor produced in the generator. Water is then stored in the storage tank. Heat is thus stored in the form of chemical energy in the concentrated acid. The heat removed from the water vapor can be supplied to a heat load of proper temperature or can be rejected. During a discharge cycle, water in the evaporator is supplied with heat to generate water vapor, which is transmitted to the absorber where it is condensed and absorbed into the concentrated acid. Both heats of dilution and condensation of water are removed from the thus diluted acid. During the discharge cycle the system functions as a heat pump in which heat is added to the system at a low temperature and removed from the system at a high temperature. The diluted acid is stored in an acid storage tank or is routed directly to the generator for reconcentration. The generator, condenser, evaporator, and absorber all are operated under pressure conditions specified by the desired temperature levels for a given application. The storage tanks, however, can be maintained at or near ambient pressure conditions. In another form, the heat pump system is employed to provide usable heat from waste process heat by upgrading the temperature of the waste heat.

Clark, Edward C. (Woodinville, WA); Huxtable, Douglas D. (Bothell, WA)

1985-08-06T23:59:59.000Z

132

Ductless Heat Pumps  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Heaters Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales...

133

Heat pump having improved defrost system  

DOE Patents (OSTI)

A heat pump system includes, in an operable relationship for transferring heat between an exterior atmosphere and an interior atmosphere via a fluid refrigerant: a compressor; an interior heat exchanger; an exterior heat exchanger; an accumulator; and means for heating the accumulator in order to defrost the exterior heat exchanger. 2 figs.

Chen, F.C.; Mei, V.C.; Murphy, R.W.

1998-12-08T23:59:59.000Z

134

Practical Approach to Water System Optimal Operation  

Science Journals Connector (OSTI)

Abstract Optimal pump scheduling is a major consideration when dealing with minimizing operational costs of a water distribution system. Pump operation must balance between three factors. Water balance constraints, including consumer demand and water tank volumes. Hydraulic constraints determining water pump operating point. Electrical tariff rate effecting energy cost. Optimization models may assume linear or discrete pump operation, depending on type and accuracy of the model in use. Linear operation assumes the pump may operate during part of the time step while discrete operation requires the pump to be either on or off during the entire time step. Linear optimization models commonly have short solution times, but cannot contain non-linear constraints such as hydraulic headloss. By such, linear model results may be difficult to implement in a real water system as the hydraulic behavior of the system may render the optimal solution impractical. Likewise, if the pump operation partially uses the time step the pump may be forced to come in and out of duty often causing mechanical ware and tare. Discrete operation provides smooth pump operation and may contain non-linear hydraulic constraint to calculate a more realistic working point for the pump. Discrete models have long solution times due the vast amount of pump operating combinations, which must be explored. Heuristic techniques may be used to shorten solution times but these do not assure global minimization of the solution. The goal of the research is to create a minimum cost optimal operation water distribution system model that utilizes the short solution time of a linear model but also includes non-linear hydraulic constraints effecting pump energy consumption and discrete pump operation. The motivation is to use the model for real-time pump scheduling and for water system design.

E. Price; A. Ostfeld

2014-01-01T23:59:59.000Z

135

An ancillary pumping system for the APS vacuum system  

SciTech Connect

An ancillary pumping system has been designed and installed in the Advanced Photon Source (APS) storage ring. This vacuum system has the ability to pump sectors of the storage ring down from room pressure to ultra-high vacuum (UHV). The ancillary system is a {open_quotes}dry{close_quotes} system that uses a combination of turbomolecular pumps and oil-free roughing pumps. The benefits of this system are the reduction of equipment needed for in-tunnel maintenance, essential for the operation of a UHV storage ring; rapid response to vacuum emergencies and a guard to accidental exposures to hydrocarbon contamination. The operational logic and the pump interlock and controls are described.

Walters, D.; Noonan, J.; Gagliano, J. [and others

1997-06-01T23:59:59.000Z

136

Variational properties of a pumped dynamical system  

SciTech Connect

We earlier constructed a generalized entropy concept to show the direction of time in an evolution following from a Markov generator. In such a dynamical system the entity found changes in a monotonic way starting from any initial state of the system. In this article, we generalize the treatment to the case when population is pumped into the system from levels not explicitly considered. These populations then pass through the coupled levels and exit by decay to levels outside the system. We derive the form of the equation of motion and relate it to our earlier treatments. It turns out that the formalism can be generalized to the new situation. Its physically relevant features are demonstrated and the behavior obtained is illustrated by a numerical treatment of the standard two-level system with pumping and relaxation included.

Andersson, Erika [SUPA, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Stenholm, Stig [Physics Department, Royal Institute of Technology, KTH, Stockholm (Sweden); Laboratory of Computational Engineering, HUT, Espoo (Finland)

2010-02-15T23:59:59.000Z

137

Minimizing Energy Consumption in a Water Distribution System: A Systems Modeling Approach  

E-Print Network (OSTI)

In a water distribution system from groundwater supply, the bulk of energy consumption is expended at pump stations. These pumps pressurize the water and transport it from the aquifer to the distribution system and to elevated storage tanks. Each...

Johnston, John

2011-08-08T23:59:59.000Z

138

A Computational Analysis of Smart Timing Decisions for Heating Based on an Air-to-Water Heat pump SMARTER EUROPE E-world energy & water 2014 Proceedings page 1  

E-Print Network (OSTI)

A Computational Analysis of Smart Timing Decisions for Heating Based on an Air-to-Water Heat pump Decisions for Heating Based on an Air-to-Water Heat pump Jan Treur VU University Amsterdam, Agent Systems be most efficient to use this energy in these periods. For air to water heat pumps a similar issue occurs

Treur, Jan

139

Geothermal pump down-hole energy regeneration system  

DOE Patents (OSTI)

Geothermal deep well energy extraction apparatus is provided of the general kind in which solute-bearing hot water is pumped to the earth's surface from a subterranean location by utilizing thermal energy extracted from the hot water for operating a turbine motor for driving an electrical power generator at the earth 3 s surface, the solute bearing water being returned into the earth by a reinjection well. Efficiency of operation of the total system is increased by an arrangement of coaxial conduits for greatly reducing the flow of heat from the rising brine into the rising exhaust of the down-well turbine motor.

Matthews, Hugh B. (Boylston, MA)

1982-01-01T23:59:59.000Z

140

Hedgehog(tm) Water Contaminant Removal System - Energy Innovation...  

NLE Websites -- All DOE Office Websites (Extended Search)

recirculating treatment system reduces the levels of contaminants in water storage tanks. A recirculation pump continually sends water though a treatment in order to reduce...

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

A NORMETEX MODEL 15 M3/HR WATER VAPOR PUMPING TEST  

SciTech Connect

Tests were performed using a Model 15 m{sup 3}/hr Normetex vacuum pump to determine if pump performance degraded after pumping a humid gas stream. An air feed stream containing 30% water vapor was introduced into the pump for 365 hours with the outlet pressure of the pump near the condensation conditions of the water. Performance of the pump was tested before and after the water vapor pumping test and indicated no loss in performance of the pump. The pump also appeared to tolerate small amounts of condensed water of short duration without increased noise, vibration, or other adverse indications. The Normetex pump was backed by a dual-head diaphragm pump which was affected by the condensation of water and produced some drift in operating conditions during the test.

Klein, J.; Fowley, M.; Steeper, T.

2010-12-20T23:59:59.000Z

142

Energy Efficient Pump Control for an Offshore Oil Processing System  

E-Print Network (OSTI)

Energy Efficient Pump Control for an Offshore Oil Processing System Zhenyu Yang Kian Soleiman Bo, Denmark. Abstract: The energy efficient control of a pump system for an offshore oil processing system control, energy saving 1. INTRODUCTION Pump systems have been extensively used in offshore oil & gas

Yang, Zhenyu

143

Pumping System Measurements To Estimate Energy Savings: Why and How  

E-Print Network (OSTI)

Measuring performance parameters (flow rate, pressures, and power) for existing systems is essential to understanding how both the pump(s) and system are actually performing. Examples of reasons why actual measurements are critical and practical...

Casada, D.

2007-01-01T23:59:59.000Z

144

Case study of underground pipe ground coupled heat pump system  

Science Journals Connector (OSTI)

Aiming to give some advices on the ground coupled heat pump system design in Sichuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year,...

Min Zheng ??; Bai-yi Li ???; Zheng-yong Qiao ???

2012-03-01T23:59:59.000Z

145

Electric Fuel Pump Condition Monitor System Using Electricalsignature Analysis  

DOE Patents (OSTI)

A pump diagnostic system and method comprising current sensing probes clamped on electrical motor leads of a pump for sensing only current signals on incoming motor power, a signal processor having a means for buffering and anti-aliasing current signals into a pump motor current signal, and a computer having a means for analyzing, displaying, and reporting motor current signatures from the motor current signal to determine pump health using integrated motor and pump diagnostic parameters.

Haynes, Howard D [Knoxville, TN; Cox, Daryl F [Knoxville, TN; Welch, Donald E [Oak Ridge, TN

2005-09-13T23:59:59.000Z

146

Covered Product Category: Residential Heat Pump Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including residential heat pump water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

147

Water-to-Air Heat Pump Performance with Lakewater  

E-Print Network (OSTI)

The performance of water-to-air heat pumps using lakewater as the heat source and sink has been investigated. Direct cooling with deep lakewater has also been considered. Although the emphasis of the work was with southern lakes, many results also...

Kavanaugh, S.; Pezent, M. C.

1989-01-01T23:59:59.000Z

148

Study on the LWT control schemes of a heat pump for hot water supply  

Science Journals Connector (OSTI)

Heat pump systems have been widely used in buildings and industries due to their high performance. In this study, a leaving water temperature control scheme has been proposed for a water-to-water heat pump for hot water supply. The study was focused on the following four schemes: (1) using an auxiliary electric heater, (2) varying compressor speed, (3) adjusting water flow rate, and (4) adding heat to the secondary fluid flow of the heat source. With schemes (2) and (3), the system showed higher performance than other schemes. However, scheme (2) could not attain the appropriate LWT at low EWT heat source conditions. For all EWT conditions, using schemes (3) and (4) enabled the system to reach an appropriate LWT. Scheme (4) can be adopted as the best technology to control LWT, because it is not easy to vary flow rate of the secondary fluid as in scheme (3).

Jong Min Choi

2013-01-01T23:59:59.000Z

149

THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER  

E-Print Network (OSTI)

#12;THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER Laboratory testing and field testing have shown that a heat pump water heater (HPWH) uses about half the electrical energy input that an electric resistance water heater does. However, since the heat pump water heater

Oak Ridge National Laboratory

150

Optimized Pump Systems Save Coal Preparation Plant Money and Energy  

Energy.gov (U.S. Department of Energy (DOE))

This case study describes how Peabody Holding Company was able to improve the performance of a coal slurry pumping system at its Randolph Coal Preparation plant. Using a systematic approach, three energy-saving opportunities were identified involving the motor, belt drive, and pump components of the pumping system. The modifications saved 87,184 kWh of electricity, equivalent to $5,231 in annual energy cost savings, and overall energy consumption of the pumping system decreased by approximately 15 percent.

151

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

Sparn, B.; Hudon, K.; Christensen, D.

2014-06-01T23:59:59.000Z

152

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM  

SciTech Connect

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

153

Utilization of Heat Pump Water Heaters for Load Management  

SciTech Connect

The Energy Conservation Standards for Residential Water Heaters require residential electric storage water heaters with volumes larger than 55 gallons to have an energy factor greater than 2.0 after April 2015. While this standard will significantly increase the energy efficiency of water heaters, large electric storage water heaters that do not use heat pump technologies may no longer be available. Since utilities utilize conventional large-volume electric storage water heaters for thermal storage in demand response programs, there is a concern that the amended standard will significantly limit demand response capacity. To this end, Oak Ridge National Laboratory partnered with the Tennessee Valley Authority to investigate the load management capability of heat pump water heaters that meet or exceed the forthcoming water heater standard. Energy consumption reduction during peak periods was successfully demonstrated, while still meeting other performance criteria. However, to minimize energy consumption, it is important to design load management strategies that consider the home s hourly hot water demand so that the homeowner has sufficient hot water.

Boudreaux, Philip R [ORNL; Jackson, Roderick K [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Lyne, Christopher T [ORNL

2014-01-01T23:59:59.000Z

154

Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes...  

Energy Savers (EERE)

Air-to-Water Heat Pumps With Radiant Delivery in Low Load Homes Tucson, Arizona and Chico, California PROJECT INFORMATION Project Name: Field testing of air-to-water heat pump...

155

Thermally conductive cementitious grout for geothermal heat pump systems  

DOE Patents (OSTI)

A thermally conductive cement-sand grout for use with a geothermal heat pump system. The cement sand grout contains cement, silica sand, a superplasticizer, water and optionally bentonite. The present invention also includes a method of filling boreholes used for geothermal heat pump systems with the thermally conductive cement-sand grout. The cement-sand grout has improved thermal conductivity over neat cement and bentonite grouts, which allows shallower bore holes to be used to provide an equivalent heat transfer capacity. In addition, the cement-sand grouts of the present invention also provide improved bond strengths and decreased permeabilities. The cement-sand grouts can also contain blast furnace slag, fly ash, a thermoplastic air entraining agent, latex, a shrinkage reducing admixture, calcium oxide and combinations thereof.

Allan, Marita (Old Field, NY)

2001-01-01T23:59:59.000Z

156

Field Testing of Pre-Production Prototype Residential Heat Pump Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Provides and overview of field testing of 18 pre-production prototype residential heat pump water heaters

157

Peak Demand Reduction with Dual-Source Heat Pumps Using Municipal Water  

E-Print Network (OSTI)

The objective of this project was to examine a dual-source (air and/or water-coupled) heat pump concept which would reduce or eliminate the need for supplemental electrical resistance heating (strip heaters). The project examined two system options...

Morehouse, J. H.; Khan, J. A.; Connor, L. N.; Pal, D.

158

Hot water tank for use with a combination of solar energy and heat-pump desuperheating  

DOE Patents (OSTI)

A water heater or system is described which includes a hot water tank having disposed therein a movable baffle to function as a barrier between the incoming volume of cold water entering the tank and the volume of heated water entering the tank which is heated by the circulation of the cold water through a solar collector and/or a desuperheater of a heat pump so as to optimize the manner in which heat is imparted to the water in accordance to the demand on the water heater or system. A supplemental heater is also provided and it is connected so as to supplement the heating of the water in the event that the solar collector and/or desuperheater cannot impart all of the desired heat input into the water.

Andrews, J.W.

1980-06-25T23:59:59.000Z

159

Development of Environmentally Benign Heat Pump Water Heaters for the US Market  

SciTech Connect

Improving energy efficiency in water heating applications is important to the nation's energy strategies. Water heating in residential and commercial buildings accounts for about 10% of U.S. buildings energy consumption. Heat pump water heating (HPWH) technology is a significant breakthrough in energy efficiency, as an alternative to electric resistance water heating. Heat pump technology has shown acceptable payback period with proper incentives and successful market penetration is emerging. However, current HPWH require the use of refrigerants with high Global Warming Potential (GWP). Furthermore, current system designs depend greatly on the backup resistance heaters when the ambient temperature is below freezing or when hot water demand increases. Finally, the performance of current HPWH technology degrades greatly as the water set point temperature exceeds 330 K. This paper presents the potential for carbon dioxide, CO2, as a natural, environmentally benign alternative refrigerant for HPWH technology. In this paper, we first describe the system design, implications and opportunities of operating a transcritical cycle. Next, a prototype CO2 HPWH design featuring flexible component evaluation capability is described. The experimental setup and results are then illustrated followed by a brief discussion on the measured system performance. The paper ends with conclusions and recommendations for the development of CO2 heat pump water heating technology suitable for the U.S. market.

Abdelaziz, Omar [ORNL] [ORNL; Wang, Kai [ORNL] [ORNL; Vineyard, Edward Allan [ORNL] [ORNL; Roetker, Jack [General Electric - Appliance Park] [General Electric - Appliance Park

2012-01-01T23:59:59.000Z

160

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Performance Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Technical Report NREL/TP-5500-52635 September 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Prepared under Task Nos. WTN9.1000, ARRB.2204 Technical Report NREL/TP-5500-52635 September 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government.

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Advances in the Research of Heat Pump Water Heaters  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future Vol.VIII-12-2 1 Advances in the Research of Heat Pump Water Heaters Shangli Shan Dandan Wang Ruixiang Wang Master Master Professor Beijing...) [21] Wang sui-lin . Affection on fin-and-tube Heat Exchanger's Properties by non azeotropic mixtures[J] . Fluid machinery , 1996 , 24 (5) [22] Ge run-ting . Foundation of Dynamic Parameter Model and Theoritical Calculation of Evaporator...

Shan, S.; Wang, D.; Wang, R.

2006-01-01T23:59:59.000Z

162

Heat pump system with selective space cooling  

DOE Patents (OSTI)

A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve. 4 figs.

Pendergrass, J.C.

1997-05-13T23:59:59.000Z

163

Heat pump system with selective space cooling  

DOE Patents (OSTI)

A reversible heat pump provides multiple heating and cooling modes and includes a compressor, an evaporator and heat exchanger all interconnected and charged with refrigerant fluid. The heat exchanger includes tanks connected in series to the water supply and a condenser feed line with heat transfer sections connected in counterflow relationship. The heat pump has an accumulator and suction line for the refrigerant fluid upstream of the compressor. Sub-cool transfer tubes associated with the accumulator/suction line reclaim a portion of the heat from the heat exchanger. A reversing valve switches between heating/cooling modes. A first bypass is operative to direct the refrigerant fluid around the sub-cool transfer tubes in the space cooling only mode and during which an expansion valve is utilized upstream of the evaporator/indoor coil. A second bypass is provided around the expansion valve. A programmable microprocessor activates the first bypass in the cooling only mode and deactivates the second bypass, and vice-versa in the multiple heating modes for said heat exchanger. In the heating modes, the evaporator may include an auxiliary outdoor coil for direct supplemental heat dissipation into ambient air. In the multiple heating modes, the condensed refrigerant fluid is regulated by a flow control valve.

Pendergrass, Joseph C. (Gainesville, GA)

1997-01-01T23:59:59.000Z

164

Heat Pump Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heater Basics Water Heater Basics Heat Pump Water Heater Basics August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a larger one on the bottom. In the top chamber are a fan, a cylindrical compressor, and an evaporator that runs along the inside of the chamber. Jutting out from the exterior of the bottom chamber is a temperature and pressure relief valve. This valve has a tube called a hot water outlet attached to the top. Below the valve is the upper thermostat, a small square outside the cylinder that is attached to a curved tube inside the heater. Resistance elements run from the upper thermostat to the similarly shaped lower thermostat. Below the lower thermostat is a drain valve with a cold water inlet attached to the top. Inside the cylinder is an anode, a series of thin tubes running through the bottom chamber to a coiled tube called a condenser. Insulation runs along the inside of the cylinder.

165

Acid mine water aeration and treatment system  

DOE Patents (OSTI)

An in-line system is provided for treating acid mine drainage which basically comprises the combination of a jet pump (or pumps) and a static mixer. The jet pump entrains air into the acid waste water using a Venturi effect so as to provide aeration of the waste water while further aeration is provided by the helical vanes of the static mixer. A neutralizing agent is injected into the suction chamber of the jet pump and the static mixer is formed by plural sections offset by 90 degrees.

Ackman, Terry E. (Finleyville, PA); Place, John M. (Bethel Park, PA)

1987-01-01T23:59:59.000Z

166

Onsite Wastewater Treatment Systems: Pump Tank  

E-Print Network (OSTI)

Pump tanks are concrete, fiberglass or polyethylene containers that collect wastewater to be dosed into the soil at intervals. This publication explains the design and maintenance of pump tanks, and it offers advice on what to do if a pump tank...

Lesikar, Bruce J.

2008-10-23T23:59:59.000Z

167

HEAT RECOVERY FROM WASTE WATER BY MEANS OF A RECUPERATIVE HEAT EXCHANGER AND A HEAT PUMP  

Science Journals Connector (OSTI)

ABSTRACT The useful heat of warm waste water is generally transferred to cold water using a recuperative heat exchanger. Depending on its design, the heat exchanger is able to utilise up to 90% of the waste heat potential available. The electric energy needed to operate such a system is more than compensated for by an approximately 50-fold gain of useful heat. To increase substantially the waste heat potential available and the amount of heat recovered, the system for recuperative heat exchange can be complemented by a heat pump. Such a heat recovery system on the basis of waste water is being operated in a public indoor swimming pool. Here the recuperative heat exchanger accounts for about 60%, the heat pump for about 40% of the toal heat reclaimed. The system consumes only 1 kWh of electric energy to supply 8 kWh of useful heat. In this way the useful heat of 8 kWh is compensated for by the low consumption of primary energy of 2.8 kWh. Due to the installation of an automatic cleaning device, the heat transfer surfaces on the waste water side avoid deposits so that the troublesome maintenance work required in other cases on the heat exchangers is not required. KEYWORDS Shower drain water, recuperative heat recovery, heat recovery by means of a heat pump, combination of both types of heat recovery, automatic cleaning device for the heat exchangers, ratio of useful heat supply vs. electric energy consumption, economic consideration.

K. Biasin; F.D. Heidt

1988-01-01T23:59:59.000Z

168

Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Carbon Dioxide-Based Carbon Dioxide-Based Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on AddThis.com...

169

Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Gas-Fired Absorption Gas-Fired Absorption Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on AddThis.com...

170

DYNAMIC MODEL OF AN INDUSTRIAL HEAT PUMP USING WATER AS REFRIGERANT  

E-Print Network (OSTI)

1 DYNAMIC MODEL OF AN INDUSTRIAL HEAT PUMP USING WATER AS REFRIGERANT CHAMOUN MARWAN to improve industrial energy efficiency, the development of a high temperature heat pump using water vapor as refrigerant is investigated. Technical problems restraining the feasibility of this industrial heat pump

Paris-Sud XI, Université de

171

Limiting Pumping from the Edwards Aquifer: An Economic Investigation of Proposals, Water Markets and Springflow Guarantees  

E-Print Network (OSTI)

Limiting Pumping from the Edwards Aquifer: An Economic Investigation of Proposals, Water Markets for pumping and springflow which in turn provides water for recreation and habitat for several endangered species. A management authority is charged with aquifer management and is mandated to reduce pumping

McCarl, Bruce A.

172

Trimming of a ground source heat pump system in Saltsjöbaden.  

E-Print Network (OSTI)

?? The real performance of ground source heat pumps systems are not precisely highlighted in most cases, especially when it comes to installations older than… (more)

Garnier, Michel

2014-01-01T23:59:59.000Z

173

Improving Pumping System Performance: A Sourcebook for Industry, Second Edition  

SciTech Connect

Prepared for the DOE Industrial Technologies Program, this sourcebook contains the practical guidelines and information manufacturers need to improve the efficiency of their pumping systems.

Not Available

2006-05-01T23:59:59.000Z

174

Simulation Study of Heat Transportation in an Aquifer about Well-water-source Heat Pump  

E-Print Network (OSTI)

The study of groundwater reinjection, pumping and heat transportation in an aquifer plays an important theoretical role in ensuring the stability of deep-well water reinjection and pumping as well as smooth reinjection. Based on the related...

Cong, X.; Liu, Y.; Yang, W.

2006-01-01T23:59:59.000Z

175

Improving Pumping System Performance: A Sourcebook for Industry- Second Edition  

Energy.gov (U.S. Department of Energy (DOE))

This sourcebook is designed to provide pump system users with a reference that outlines opportunities for improving system performance. It is not meant to be a comprehensive technical text on pumping systems; rather, it provides practical guidelines and information to make users aware of potential performance improvements. Guidance on how to find more information and assistance is also included.

176

Development of High-Pressure Dry Feed Pump for Gasification Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Pressure Dry Feed Pressure Dry Feed Pump for Gasification Systems Background Even though coal-based power generation via Integrated Gasification Combined Cycle (IGCC) is more efficient, cleaner, and uses less water than conventional pulverized coal burning systems, widespread IGCC deployment has not occurred because of its relatively high cost. The Pratt & Whitney Rocketdyne (PWR) high-pressure dry feed pump addresses IGCC cost disparity by enabling lower cost and more reliable coal feed

177

Expert system for online surveillance of nuclear reactor coolant pumps  

DOE Patents (OSTI)

An expert system for online surveillance of nuclear reactor coolant pumps. This system provides a means for early detection of pump or sensor degradation. Degradation is determined through the use of a statistical analysis technique, sequential probability ratio test, applied to information from several sensors which are responsive to differing physical parameters. The results of sequential testing of the data provide the operator with an early warning of possible sensor or pump failure.

Gross, Kenny C. (Bolingbrook, IL); Singer, Ralph M. (Naperville, IL); Humenik, Keith E. (Columbia, MD)

1993-01-01T23:59:59.000Z

178

Training: Pumping Systems | Department of Energy  

Office of Environmental Management (EM)

end users, DOE is working with the pumping industry and the Hydraulic Institute to train and qualify experts in the use of PSAT. The qualifying workshops prepare professionals...

179

Hybrid Geothermal Heat Pump System Research Geothermal Project | Open  

Open Energy Info (EERE)

Hybrid Geothermal Heat Pump System Research Geothermal Project Hybrid Geothermal Heat Pump System Research Geothermal Project Jump to: navigation, search Last modified on July 22, 2011. Project Title Hybrid Geothermal Heat Pump System Research Project Type / Topic 1 Recovery Act - Geothermal Technologies Program: Ground Source Heat Pumps Project Type / Topic 2 Topic Area 2: Data Gathering and Analysis Project Description Geothermal, or ground-source heat pump systems have been shown to have superior energy performance to conventional heating and cooling systems in many building types and climates. There has been significant growth in the application of these systems; yet, geothermal systems have only been able to capture a few percent of the heating and cooling market. This is due primarily to the prohibitively high cost of installing the necessary ground loop.

180

Thermoeconomic Analysis of a Solar Heat-Pump System  

E-Print Network (OSTI)

This paper introduces a solar energy heat-pump system and analyzes the thermoeconomics. The results show that the solar energy heat-pump system can be operated in different modes and used for room heating in winter and cooling in summer and...

Gao, Y.; Wang, S.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

APPLICATIONS OF HYBRID GROUND SOURCE HEAT PUMP SYSTEMS TO  

E-Print Network (OSTI)

APPLICATIONS OF HYBRID GROUND SOURCE HEAT PUMP SYSTEMS TO BUILDINGS AND BRIDGE DECKS. By MAHADEVAN PUMP SYSTEMS TO BUILDINGS AND BRIDGE DECKS. Thesis Approved cannot find enough words to thank my father, H. Ramamoorthy, my mother, R. Devasena, and my brother

182

ENERGY ABSORBER HEAT PUMP SYSTEM TO SUPPLEMENT HEAT RECOVERY SYSTEMS IN AN INDOOR SWIMMING POOL  

Science Journals Connector (OSTI)

ABSTRACT Compared with convontional indoor swimming pools with traditional plant engineering, the Schwalmtal indoor swimming pool has a final energy consumption of just 40%. This low consumption is achieved by improved insulation of the building's enveloping surface, through the operation of systems for the recovery of heat from drain water and waste air as well as by the operation of a heat pump system to gain ambient heat. The decentralised heat recovery systems met between 40 and 80% of the heat requirements in the supply areas where they were used. The electric heat pump system, which is operated in the bivalent mode in parallel to a heating boiler, could generate 75% of the heat provided by the central heating circuit to meet the residual heat requirements. The report illustrates the structure of the residual heat requirements of the central heating circuit. A description is given of the measured coefficients of performance of the brine/water heat pump connected by a brine circuit with two different energy absorber types - energy stack and energy roof. Finally, the ambient energy gained with the absorbers is broken down into the various kinds of heat gains from radiation, convection, condensation etc. KEYWORDS Energy absorber; energy stack; energy roof; heat pump; heat recovery systems; indoor swimming pool; energy engineering concept.

K. Leisen

1988-01-01T23:59:59.000Z

183

Solar Colletors Combined with Ground-Source Heat Pumps in Dwellings - Analyses of System Performance.  

E-Print Network (OSTI)

??The use of ground-source heat pumps for heating buildings and domestic hot water in dwellings is increasing rapidly in Sweden. The heat pump extracts heat… (more)

Kjellsson, Elisabeth

2009-01-01T23:59:59.000Z

184

Submersible purification system for radioactive water  

DOE Patents (OSTI)

A portable, submersible water purification system for use in a pool of water containing radioactive contamination includes a prefilter for filtering particulates from the water. A resin bed is then provided for removal of remaining dissolved, particulate, organic, and colloidal impurities from the prefiltered water. A sterilizer then sterilizes the water. The prefilter and resin bed are suitably contained and are submerged in the pool. The sterilizer is water tight and located at the surface of the pool. The water is circulated from the pool through the prefilter, resin bed, and sterilizer by suitable pump or the like. In the preferred embodiment, the resin bed is contained within a tank which stands on the bottom of the pool and to which a base mounting the prefilter and pump is attached. An inlet for the pump is provided adjacent the bottom of the pool, while the sterilizer and outlet for the system is located adjacent the top of the pool.

Abbott, Michael L. (Fort Collins, CO); Lewis, Donald R. (Pocatello, ID)

1989-01-01T23:59:59.000Z

185

Georgia Power- Residential Solar and Heat Pump Water Heater Rebate (Georgia)  

Energy.gov (U.S. Department of Energy (DOE))

Georgia Power customers may be eligible for rebates up to $250 each toward the installation costs of a 50 gallon or greater solar water heater or heat pump water heater. The solar water heater or...

186

Pump and control unit for a solar heating installation for a water tank and particularly for a swimming pool  

SciTech Connect

The invention relates to a pump and control unit for a solar heating installation system for a water tank, particularly for a swimming pool. The system contains a solar collector, a hydraulic circuit which includes an outward-flow pipe, a return-flow pipe, a pump, a derivative-action control unit and two sensors mounted on the outward-flow pipe and on the return-flow pipe, respectively. The pump, the control unit and the two sensors are integrated into a single case. The case is provided in its top wall with a transparent opening which faces the return-flow sensor and through which said sensor can be exposed to solar radiation, such that the pump may be automatically activated during periods of sunshine, i.e., when the solar collector is heating the water returning to the tank, and stopped due to lack of sunshine.

Cannaux, G.; Calvet, G.

1985-09-17T23:59:59.000Z

187

Hand-pumps as reservoirs for microbial contamination of well water  

E-Print Network (OSTI)

Hand-pumps as reservoirs for microbial contamination of well water Andrew S. Ferguson, Brian J and release of total coliforms and Escherichia coli was investigated in hand-pumps removed from tubewells tapping a faecally contaminated aquifer in Matlab, Bangladesh, and from a new hand-pump deliberately

van Geen, Alexander

188

A key review of wastewater source heat pump (WWSHP) systems  

Science Journals Connector (OSTI)

Abstract Heat pumps (HPs) are part of the environmentally friendly technologies using renewable energy and have been utilized in the developed countries for years. Wastewater is seen as a renewable heat source for HPs. At the beginning of the 1980s, waste (sewage) water source heat pumps (WWSHPs) were widely applied in North European countries like Sweden and Norway and partially applied in China. In the past two decades, the WWSHP has become increasingly popular due to its advantages of relatively higher energy utilization efficiency and environmental protection. The present study comprehensively reviews WWSHP systems in terms of applications and performance assessments including energetic, exergetic, environmental and economic aspects for the first time to the best of the authors’ knowledge. In this context, a historical development of \\{WWSHPs\\} was briefly given first. Next, wastewater potential and its characteristics were presented while a WWSHP system was introduced. The previously conducted studies on \\{WWSHPs\\} were then reviewed and classified in a tabulated form. Finally, some concluding remarks were listed. The COP values of the reviewed studies ranged from 1.77 to 10.63 for heating and 2.23 to 5.35 for cooling based on the experimental and simulated values. The performance assessments are mostly made using energy analysis methods while the number of exergetic evaluations is very low and has not been comprehensively performed. It is expected that the comprehensive review here will be very beneficial to those dealing with the design, analysis, simulation and performance assessment of WWSHP systems.

Arif Hepbasli; Emrah Biyik; Orhan Ekren; Huseyin Gunerhan; Mustafa Araz

2014-01-01T23:59:59.000Z

189

Energy Efficient Integration of Heat Pumps into Solar District Heating Systems with Seasonal Thermal Energy Storage  

Science Journals Connector (OSTI)

Abstract Solar district heating (SDH) with seasonal thermal energy storage (STES) is a technology to provide heat for space heating and domestic hot water preparation with a high fraction of renewable energy. In order to improve the efficiency of such systems heat pumps can be integrated. By preliminary studies it was discovered, that the integration of a heat pump does not always lead to improvements from an overall energy perspective, although the operation of the heat pump increases the efficiency of other components of the system e. g. the STES or the solar collectors. Thus the integration of heat pumps in SDH systems was investigated in detail. Usually, the heat pumps are integrated in such a way, that the STES is used as low temperature heat source. No other heat sources from the ambience are used and only that amount of energy consumed by the heat pump is additionally fed into the system. In the case of an electric driven heat pump, this is highly questionable concerning economic and CO2-emission aspects. Despite that fact the operation of the heat pump influences positively the performance of other components in the system e. g. the STES and makes them more efficient. If the primary energy consumption of the heat pump is lower than the energetic benefits of all other components, the integration makes sense from an energetic point of view. A detailed assessment has been carried out to evaluate the most promising system configurations for the integration of a heat pump. Based on this approach a system concept was developed in which the integration of the heat pump is energetically further improved compared to realised systems. By means of transient system simulations this concept was optimised with regard to the primary energy consumption. A parameter study of this new concept has been performed to identify the most sensitive parameters of the system. The main result and conclusion are that higher solar fractions and also higher primary energy savings can be achieved by SDH systems using heat pumps compared systems without heat pumps.

Roman Marx; Dan Bauer; Harald Drueck

2014-01-01T23:59:59.000Z

190

Designing, selecting and installing a residential ground-source heat pump system  

SciTech Connect

It's a compelling proposition: Use the near-constant-temperature heat underground to heat and cool your home and heat domestic water, slashing your energy bills. Yet despite studies demonstrating significant energy savings from ground-source heat pump (GSHP) systems, their adoption has been hindered by high upfront costs. Fewer than 1% of US homes use a GSHP system. However, compared to a minimum-code-compliant conventional space-conditioning system, when properly designed and installed, a GSHP retrofit at current market prices offers simple payback of 4.3 years on national average, considering existing federal tax credits. Most people understand how air-source heat pumps work: they move heat from indoor air to outdoor air when cooling and from outdoor air to indoor air when heating. The ground-source heat pump operates on the same principle, except that it moves heat to or from the ground source instead of outdoor air. The ground source is usually a vertical or horiontal ground heat exchanger. Because the ground usually has a more favorable temperature than ambient air for the heating and cooling operation of the vapor-compression refrigeration cycle, GSHP sysems can operate with much higher energy efficiencies than air-source heat pump systems when properly designed and installed. A GSHP system used in a residual building typically provides space conditioning and hot water and comprises three major components: a water-source heat pump unit designed to operate at a wider range of entering fluid temperatures (typically from 30 F to 110 F, or 1 C to 43 C) than a conventional water-source heat pump unit; a ground heat exchanger (GHX); and distribution systems to deliver hot water to the storage tank and heating or cooling to the conditioned rooms. In most residual GSHP systems, the circulation pumps and associated valves are integrated with the heat pump to circulate the heat-carrier fluid (water or aqueous antifreeze solution) through the heat pump and the GHX. A recent assessment indicates that if 20% of US homes replaced their existing space-conditioning and water-heating systems with properly designed, installed and operated state-of-the-art GSHP systems, it would yield significant benefits each year. These include 0.8 quad British thermal units (Btu) of primary energy savings, 54.3 million metric tons of CO{sub 2} emission reductions, $10.4 billion in energy cost savings and 43.2 gigawatts of reduction in summer peak electrical demand.

Hughes, Patrick [ORNL; Liu, Xiaobing [ORNL; Munk, Jeffrey D [ORNL

2010-01-01T23:59:59.000Z

191

Solar Hot Water Heater Augmented with PV-TEM Heat Pump.  

E-Print Network (OSTI)

??Solar assisted heat pumps (SAHPs) can provide higher collector efficiencies and solar fractions when compared against standard solar hot water heaters. Vapour compression (VC) heat… (more)

PRESTON, NATHANIEL

192

Combined permeable pavement and ground source heat pump systems   

E-Print Network (OSTI)

The PhD thesis focuses on the performance assessment of permeable pavement systems incorporating ground source heat pumps (GSHP). The relatively high variability of temperature in these systems allows for the survival of pathogenic organisms within...

Grabowiecki, Piotr

2010-01-01T23:59:59.000Z

193

Reducing Life Cycle Cost By Energy Saving in Pump Systems  

E-Print Network (OSTI)

Pumps consume about 15% of all electricity generated world wide. In the USA alone this accounts for over 130TWh per annum. A saving of only 1% would amount to $80 million in electricity cost. The importance of energy saving, in pump systems...

Bower, J. R.

194

Hot gas defrosting method for air-source transcritical CO2 heat pump systems  

Science Journals Connector (OSTI)

Abstract When the air-source heat pump systems operate at low ambient temperatures in winter, frost forms on the coil surface of the outdoor evaporators. The frost substantially affects the operating performance and energy efficiency of heat pump systems, and hence periodic defrosting is essential. In this study, several defrost methods are presented to look for a candidate for air-source transcritical CO2 heat pump systems. The hot gas method proves to be more suitable among other defrosting methods for transcritical CO2 heat pump systems. To validate its reliability and rationality, an air-source transcritical CO2 heat pump water heater was built in a climatic laboratory. Through the experiments, the dynamic process of temperature and pressure were obtained to demonstrate the hot gas defrosting characteristics and system cycle. The hot gas defrosting cycle in the p–h diagram was also validated by experiment results. Meanwhile, instant defrosting images were captured to record the dynamic defrosting process. The defrosting process lasted 10 min and defrosting efficiency was 34.8% for hot gas defrosting method. The effectiveness and applicability of hot gas defrosting method for CO2 heat pump water heater is validated by experiments.

Bin Hu; Dongfang Yang; Feng Cao; Ziwen Xing; Jiyou Fei

2015-01-01T23:59:59.000Z

195

Evaluation of water source heat pumps for the Juneau, Alaska Area  

SciTech Connect

The purposes of this project were to evaluate the technical and economic feasibility of water source heat pumps (WSHP) for use in Juneau, Alaska and to identify potential demonstration projects to verify their feasibility. Information is included on the design, cost, and availability of heat pumps, possible use of seawater as a heat source, heating costs with WSHP and conventional space heating systems, and life cycle costs for WSHP-based heating systems. The results showed that WSHP's are technically viable in the Juneau area, proper installation and maintenance is imperative to prevent equipment failures, use of WSHP would save fuel oil but increase electric power consumption. Life cycle costs for WSHP's are about 8% above that for electric resistance heating systems, and a field demonstration program to verify these results should be conducted. (LCL)

Jacobsen, J.J.; King, J.C.; Eisenhauer, J.L.; Gibson, C.I.

1980-07-01T23:59:59.000Z

196

Vapor compression heat pump system field tests at the tech complex  

Science Journals Connector (OSTI)

The Tennessee Energy Conservation In Housing (TECH) complex has been utilized since 1977 as a field test site for several novel and conventional heat pump systems for space conditioning and water heating. Systems tested include the Annual Cycle Energy System (ACES) solar assisted heat pumps (SAHP) both parallel and series two conventional air?to?air heat pumps an air?to?air heat pump with desuperheater water heater and horizontal coil and multiple shallow vertical coil ground?coupled heat pumps (GCHP). A direct comparison of the measured annual performance of the test systems was not possible. However a cursory examination revealed that the ACES had the best performance however its high cost makes it unlikely that it will achieve wide?spread use. Costs for the SAHP systems are similar to those of the ACES but their performance is not as good. Integration of water heating and space conditioning functions with a desuperheater yielded significant efficiency improvement at modest cost. The GCHP systems performed much better for heating than for cooling and may well be the most efficient alternative for residences in cold climates.

Van D. Baxter

1985-01-01T23:59:59.000Z

197

An air-to-air heat pump (COP-3.11 at 470 F (8.30C)) run alternately with an electric-resistance water  

E-Print Network (OSTI)

- ter than that of the system using electric resistance water heating. An analytical tinclel predicts of a high-efficiency heat pump'/electric-resistance .waterheater (IIP/IZR) system. TEST FACILITIES#12;/ ABSTRACT An air-to-air heat pump (COP-3.11 at 470 F (8.30C)) run alternately with an electric

Oak Ridge National Laboratory

198

Solar powered induction motor-driven water pump operating on a desert well, simulation and field tests  

Science Journals Connector (OSTI)

A photovoltaic-powered water pumping system, employing an induction motor pump, capable of supplying a daily average of 50 m3 at 37-m head has been developed. The system was installed on a desert well in Jordan, where: the average solar radiation amount to 5.5 kW h/m3/day, to provide the Bedouins living in the well area with drinking water. A mathematical model to enable testing the system performance by computer simulation was developed. This model allows the representation of motor torque in function of speed (and slip) at different supply frequencies, as well as the flow rate and efficiency of the system in function of supply frequency and pumping head. Prior to its installation on the desert well, the system performance, in accordance with frequency and head, was thoroughly tested in the laboratory. As illustrated in this paper, simulation and laboratory testing results are well matched. At constant pumping head, the flow rate is proportional to the supply frequency of the motor. At constant flow rate, the pumping head is proportional to the supply frequency squared only in the range below the peak efficiency of the pump. For higher flow rate values, a special algorithm based on the experimental results could be developed. Higher system efficiency is achievable at higher frequency. It is advisable to operate the motor pump at the nominal frequency, flow rate and head corresponding to maximum efficiency. Long-term field testing of the system shows that it is reliable and has an overall efficiency exceeding 3%, which is comparable to the highest efficiencies reported elsewhere for solar powered pumps.

Abdel-Karim Daud; Marwan M. Mahmoud

2005-01-01T23:59:59.000Z

199

Pioneering Heat Pump Project  

Energy.gov (U.S. Department of Energy (DOE))

Project objectives: To install and monitor an innovative WaterFurnace geothermal system that is technologically advanced and evolving; To generate hot water heating from a heat pump that uses non-ozone depleting refrigerant CO2. To demonstrate the energy efficiency of this system ground source heat pump system.

200

Earth-Coupled Water-Source Heat Pump Research, Design and Applications in Louisiana  

E-Print Network (OSTI)

An earth-coupled water-source heat pump uses the earth as the thermal source and sink for economical, energy efficient, space heating and cooling. Water exiting the heat pump passes through an earth heat exchanger, which is a closed loop of plastic...

Braud, H. J.; Klimkowski, H.; Baker, F. E.

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Case Study- The Challenge: Improving Sewage Pump System Performance  

Energy.gov (U.S. Department of Energy (DOE))

This case study looks at how Trumbull, Connecticut increased the energy and operating efficiency of its Reservoir Avenue sewage pump station. With the help of ITT Flygt Corporation, the town altered the existing pump system by adding a smaller pump and modifying the system control scheme. The changes reduced annual electricity consumption by almost 44 percent, or nearly 31,900 kWh, saving more than $2,600 per year. The $12,000 project had a simple payback of 4.6 years.

202

Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates  

E-Print Network (OSTI)

Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads...

Johnson, K. F.; Shedd, A. C.

203

Chapter 9 - Hydraulic Pumps  

Science Journals Connector (OSTI)

Publisher Summary This chapter provides an overview of hydraulic-powered downhole pumps, which are powered by a stream of high pressure power fluid supplied by a power fluid (PF) pump at the surface and sent to a downhole pump or pump engine. Hydraulic pumps are basically of two types—piston downhole pumps that are similar to beam down-hole pumps, and jet downhole pumps that reduce the pressure on the formation by high-speed power fluid flow through the throat of a venturi or jet pump nozzle-diffuser combination. Hydraulic pumps can be used to remove liquids from gas wells. A skid-mounted hydraulic pump can be used to kick off a gas well and then be moved to another well for testing, production, or longer term de-watering. Hydraulic pumping is generally not depth limited, and deviated or crooked wells do not present problems. Hydraulic reciprocating pumps can produce a low bottomhole pressure. A jet pump may require a fluid height over the pump of 20% of submergence. A jet pump is more trouble-free than a reciprocating hydraulic pump and can tolerate some solids in the production. Fairly high rates of more than several hundred bbls/day are possible. In general, hydraulic systems are not rate limited when removing liquids from gas wells.

James Lea; Henry Nickens; Michael Wells

2003-01-01T23:59:59.000Z

204

Building America Webinar: Central Multifamily Water Heating Systems  

Energy.gov (U.S. Department of Energy (DOE))

Hosted by DOE's Building America program, this webinar will focus on the effective use of central heat pump water heaters (HPWHs) and control systems to reduce the energy use in hot water distribution.

205

Webinar: ENERGY STAR Hot Water Systems for High Performance Homes  

Energy.gov (U.S. Department of Energy (DOE))

This presentation is from the Building America research team BA-PIRC webinar on September 30, 2011 providing informationprovide information about how to achieve energy savings from solar water heating, electric dedicated heat pump water heating, and gas tankless systems.

206

A comprehensive study on the important faults in heat pump system during the warranty period  

Science Journals Connector (OSTI)

Abstract The heat pump market has become mature in many countries. There are millions of heat pumps installed worldwide. So any improvement in the installation, operation, and maintenance of heat pump systems can save a considerable amount of energy and cost, and reduce Green House Emissions to a large extent. The present study suggests a Smart Fault Detection and Diagnosis (SFDD) mechanism as the essential part of the next generation of heat pumps. A SFDD mechanism can minimize the installation and control errors, decrease the performance degradation during operation, avoid unnecessary visual inspections and components replacement, and reduce the maintenance cost and down-time of the system. To develop a SFDD mechanism, the first essential step is to obtain knowledge about the most common and expensive faults experienced by heat pumps. The heat pump manufacturers are one of the best sources to find out the most common and costliest faults occurring in heat pump systems during the first few years of their life. The present paper, as the first part of two, describes the results from a comprehensive study done on the most recent faults which were reported to some of the heat pump manufacturers in Sweden during the warranty period. The most common and the costliest faults in the Air/Air, Air/Water, Brine/Water, and exhaust air heat pumps are presented. Some of the faults such as faulty pressure switches or fans are only related to the heat pump unit, i.e. the thermodynamic cycle which facilitates the heat pumping cycle. Some of the common and expensive faults such as faulty shuttle or shunt valve are related to the faulty components in the heating systems. Generally, the results show that faults in Control and Electronics are almost the most common and costliest faults in all types of heat pumps. Faults in Control and Electronics include any fault related to control unit, electrical faults (such as short circuit, etc.), Printed Circuit Board (PCB), display, soft starter, overcurrent and motor protection relay, etc.

Hatef Madani; Erica Roccatello

2014-01-01T23:59:59.000Z

207

Technical details regarding the design, the construction and the operation of seawater pumped storage systems  

Science Journals Connector (OSTI)

This paper presents important technical details for the design, construction and operation of seawater pumped storage systems (S-PSS). S-PSS co-operating with wind parks, features as the most promising technology towards maximizing Renewable Energy penetration in insular systems with low annual rainfalls. This article summarises the fundamental points of integrated studies of S-PSS, from the feasibility study to the precise positioning of the systems' components and the selection of the main equipment. Special issues regarding the use of seawater from the PSS (pumped storage system), such as the use of materials for the construction of the penstock, the construction of the upper reservoir, placing the pump station and the hydro power plant on the coast and the selection of pump and hydro-turbine models are presented thoroughly. Indicative results are presented from two S-PSS of small and medium size. The study proves that current technology enables the secure use of seawater in PSS. The electricity surplus from Wind Powered Pumped Storage Systems (WP-PSS) can also be exploited in reverse osmosis desalination plants for producing potable water. Seawater can be pumped directly from the sea, thus construction of a lower reservoir is avoided, compensating higher costs arising from the use of corrosion-resistant materials for certain components.

Dimitris Al. Katsaprakakis; Dimitris G. Christakis; Ioannis Stefanakis; Petros Spanos; Nikos Stefanakis

2013-01-01T23:59:59.000Z

208

U.S. Department of Energy UMTRA Ground Water Project Ground Water Pumping and Monitoring Plan  

Office of Legacy Management (LM)

GWMON 1.12-1 GWMON 1.12-1 U.S. Department of Energy UMTRA Ground Water Project Ground Water Pumping and Monitoring Plan for the Land Farm Pilot Test Monument Valley, Arizona August 2000 Prepared by U.S. Department of Energy Grand Junction Ofice Grand Junction, Colorado Project Number UGW-5 1 1-001 5-21-000 Document Number U0106701 This page intentionally left blank Document Number U0106701 Contents Contents 1.0 Introduction ....................................................................................................................... 1 2.0 Purpose and Scope ........................................................................................................... 1 3.0 Pilot-Test Extraction Wellfield 2 4.0 Water Elevation Measurements and Monitoring ............... 4

209

Is My Water Safe? disaster may disrupt the electricity needed to pump  

E-Print Network (OSTI)

. Water purification tablets -- These tablets are available at drug stores. Follow the manufacturerIs My Water Safe? A disaster may disrupt the electricity needed to pump water in the home and/or contaminate the water supply. Planning ahead can assure there is enough safe water for drinking, preparing

210

Gas-Fired Absorption Heat Pump Water Heater Research Project | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Gas-Fired Absorption Heat Pump Water Emerging Technologies » Gas-Fired Absorption Heat Pump Water Heater Research Project Gas-Fired Absorption Heat Pump Water Heater Research Project The U.S. Department of Energy (DOE) is currently conducting research into carbon gas-fired absorption heat pump water heaters. This project will employ innovative techniques to increase water heating energy efficiency over conventional gas storage water heaters by 40%. Project Description This project seeks to develop a natural gas-fired water heater using an absorption heat. The development effort is targeting lithium bromide aqueous solutions as a working fluid in order to avoid the negative implications of using more toxic ammonia. Project Partners Research is being undertaken through a Cooperative Research and Development

211

An approach to energy saving assessment of solar assisted heat pumps for swimming pool water heating  

Science Journals Connector (OSTI)

A steady state off-design model of a Water Solar Assisted Heat Pump (W-SAHP) and the results of monthly based averaged simulations are presented. The W-SAHP system is arranged with a commercial water-to-water heat pump, coupled with unglazed flat plate solar collectors. The study is purposely developed for swimming pools, however most of the analysis criteria and outcomes are valid for any building (user) having hot water needs. Calculations are made for given thermal load and user operating temperatures with reference to the climatic data of all Italian Municipalities, that is degree days (DD) in the range from 700 to 3000, altitude from 0 to 1500 m (above sea level), and latitude from 36.5°N to 46.3°N. The primary energy saving capability of the W-SAHP solution, compared to a traditional gas-boiler plant, is analyzed as a function of the DD index of each site. Despite the large spread of climatic and altitude data, the results show that the W-SAHP performance is usually well correlated to DD, which can therefore be assumed as the main independent variable for the energy saving assessment of these systems, and make the results easily extended to other possible geographical locations.

Luca A. Tagliafico; Federico Scarpa; Giulio Tagliafico; Federico Valsuani

2012-01-01T23:59:59.000Z

212

E-Print Network 3.0 - air-lift water-pumping wind-turbines Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

water-pumping wind-turbines Search Powered by Explorit Topic List Advanced Search Sample search results for: air-lift water-pumping wind-turbines Page: << < 1 2 3 4 5 > >> 1 Review...

213

Energy optimization of water distribution system  

SciTech Connect

In order to analyze pump operating scenarios for the system with the computer model, information on existing pumping equipment and the distribution system was collected. The information includes the following: component description and design criteria for line booster stations, booster stations with reservoirs, and high lift pumps at the water treatment plants; daily operations data for 1988; annual reports from fiscal year 1987/1988 to fiscal year 1991/1992; and a 1985 calibrated KYPIPE computer model of DWSD`s water distribution system which included input data for the maximum hour and average day demands on the system for that year. This information has been used to produce the inventory database of the system and will be used to develop the computer program to analyze the system.

Not Available

1993-02-01T23:59:59.000Z

214

A refrigerator-heat-pump desalination scheme for fresh-water and salt recovery  

Science Journals Connector (OSTI)

This study concerns a refrigerator-heat-pump desalination scheme (RHPDS), which allows energy-efficient recovery of fresh water and salt from the sea. In this scheme, a salt-water chamber is continuously refilled with sea water via atmospheric pressure. Sea water is evaporated into a vacuum chamber and the water vapor is condensed on top of a fresh-water chamber. A refrigerator-heat-pump circuit maintains the two water chambers at suitably different operating temperatures and allows efficient recovery of the latent heat of condensation. The scheme is analyzed with special consideration to potential exploitation of renewable energy sources such as solar and wind energy.

M. Reali

1984-01-01T23:59:59.000Z

215

Chapter 5 - Solar Water-Heating Systems  

Science Journals Connector (OSTI)

Abstract Chapter 5 is on solar water-heating systems. Both passive and active systems are described. Passive systems include thermosiphon and integrated collector storage systems. The former include theoretical performance of thermosiphon solar water heaters, reverse circulation in thermosiphon systems, vertical against horizontal tank configurations, freeze protection, and tracking thermosiphons. Subsequently, active systems are described, which include direct circulation systems, indirect water-heating systems, air water-heating systems, heat pump systems and pool heating systems, which include the analysis of various heat losses like evaporation, radiation, convection heat losses, make-up water load, and solar radiation-heat gain. Then the characteristics and thermal analysis of heat storage systems for both water and air systems are presented. The module and array design methods are then described and include the effects of shading, thermal expansion, galvanic corrosion, array sizing, heat exchangers, pipe and duct losses, partially shaded collectors and over-temperature protection—followed by an analysis of the characteristics of differential thermostats. Finally, methods to calculate the hot water demand are given as well as a review of international standards used to evaluate the solar water heaters performance. The chapter includes also simple system models and practical considerations for the setup of solar water-heating systems, which include: pipes, supports and insulation; pumps; valves and instrumentation.

Soteris A. Kalogirou

2014-01-01T23:59:59.000Z

216

Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water Heaters Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water Heaters June 14, 2012 - 7:38pm Addthis A water heater's energy efficiency is determined by the energy factor (EF), which is based on the amount of hot water produced per unit of fuel consumed over a typical day. The higher the energy factor, the more efficient the water heater. A water heater's energy efficiency is determined by the energy factor (EF), which is based on the amount of hot water produced per unit of fuel consumed over a typical day. The higher the energy factor, the more efficient the water heater. What does this mean for me? Estimate the annual operating costs and compare several water heaters to determine whether it is worth investing in a more efficient

217

The Application of Frequency-Conversion Technology in Groundwater Source Heat Pump System Reconstruction  

E-Print Network (OSTI)

Deep well pump power is relatively ubiquitous in the groundwater heat pump air-conditioning system in some hotels in Hunan, and the heat pump usually meets the change of the load by throttling. Therefore, frequency conversion technology is proposed...

Dai, X.; Song, S.

2006-01-01T23:59:59.000Z

218

A ground-coupled storage heat pump system with waste heat recovery  

SciTech Connect

This paper reports on an experimental single-family residence that was constructed to demonstrate integration of waste heat recovery and seasonal energy storage using both a ventilating and a ground-coupled heat pump. Called the Idaho energy Conservation Technology House, it combines superinsulated home construction with a ventilating hot water heater and a ground coupled water-to-water heat pump system. The ground heat exchangers are designed to economically promote seasonal and waste heat storage. Construction of the house was completed in the spring of 1989. Located in Moscow, Idaho, the house is occupied by a family of three. The 3,500 ft{sup 2} (325 m{sup 2}) two-story house combines several unique sub-systems that all interact to minimize energy consumption for space heating and cooling, and domestic hot water.

Drown, D.C.; Braven, K.R.D. (Univ. of Idaho, ID (US)); Kast, T.P. (Thermal Dynamic Towers, Boulder, CO (US))

1992-02-01T23:59:59.000Z

219

Basics of pump-and-treat ground-water remediation technology. Special report  

SciTech Connect

The pump-and-treat process, whereby contaminated ground water is pumped to the surface for treatment, is one of the most common ground-water remediation technologies used at hazardous waste sites. However, recent research has identified complex chemical and physical interactions between contaminants and the subsurface media which may impose limitations on the extraction part of the process. The report was developed to summarize the basic considerations necessary to determine when, where, and how pump-and-treat technology can be used effectively to remediate ground-water contamination.

Mercer, J.W.; Skipp, D.C.; Giffin, D.

1990-03-01T23:59:59.000Z

220

Improving Heating System Operations Using Water Re-Circulation  

E-Print Network (OSTI)

In order to solve the imbalance problem of a heating system, brought about by consumer demand and regulation, and save the electricity energy consumed by a circulation pump, a water mixing and pressure difference control heating system is proposed...

Li, F.; Han, J.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Energy Efficient Control of a Boosting System with Multiple Variable-Speed Pumps in Parallel  

E-Print Network (OSTI)

with multiple variable-speed pumps in parallel is to minimize the pump system energy consumption by controlEnergy Efficient Control of a Boosting System with Multiple Variable-Speed Pumps in Parallel Zhenyu. The experimental results show a huge potential to improve the energy efficiency of multi-pump systems using

Yang, Zhenyu

222

Modeling and Experimental Investigation of a Variable Speed Drive Water Source Heat Pump  

Science Journals Connector (OSTI)

Accurate variable speed characteristics are needed for water source heat pumps (WSHP) to design variable speed controls to adjust refrigerant flow rates in heat pumps and air conditioners. The system capacity can then be regulated to match the compressor loads to the heating or cooling needs to improve the energy efficiency and lower energy costs. The motor and compression characteristics of WSHP were modeled to include the coupling between the motor speed and the torque characteristics and compression characteristics. An analytical model is given for a variable speed hermetic scroll compressor that describes various factors, such as the drive frequency, suction pressure, and discharge pressure as a function of the compressor speed. The model was validated experimentally using R22 and \\{R134a\\} in an experimental WSHP with variable speed control using frequency conversion. The results show that the analytical model properly describes the variable speed characteristics and provides a control strategy for adjusting the capacity of scroll compressors to match the heat pump or air conditioner operating conditions.

Zhifang Xue; Lin Shi

2010-01-01T23:59:59.000Z

223

Thermal performance analysis of a direct-expansion solar-assisted heat pump water heater  

Science Journals Connector (OSTI)

A direct-expansion solar-assisted heat pump water heater (DX-SAHPWH) is described, which can supply hot water for domestic use during the whole year. The system mainly employs a bare flat-plate collector/evaporator with a surface area of 4.2 m2, an electrical rotary-type hermetic compressor, a hot water tank with the volume of 150 L and a thermostatic expansion valve. R-22 is used as working fluid in the system. A simulation model based on lumped and distributed parameter approach is developed to predict the thermal performance of the system. Given the structure parameters, meteorological parameters, time step and final water temperature, the numerical model can output operational parameters, such as heat capacity, system COP and collector efficiency. Comparisons between the simulation results and the experimental measurements show that the model is able to give satisfactory predictions. The effect of various parameters, including solar radiation, ambient temperature, wind speed and compressor speed, has been analyzed on the thermal performance of the system.

X.Q. Kong; D. Zhang; Y. Li; Q.M. Yang

2011-01-01T23:59:59.000Z

224

Enhancing geothermal heat pump systems with parametric performance analyses.  

E-Print Network (OSTI)

??Parametric performance analyses and comparison of a basic geothermal heat pump, a heat pump cycle with motor cooling/refrigerant preheating, and a heat pump cycle utilizing… (more)

Self, Stuart

2010-01-01T23:59:59.000Z

225

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)  

SciTech Connect

Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

Metzger, C.; Puttagunta, S.; Williamson, J.

2013-11-01T23:59:59.000Z

226

Optimization of a photovoltaic pumping system based on the optimal control theory  

SciTech Connect

This paper suggests how an optimal operation of a photovoltaic pumping system based on an induction motor driving a centrifugal pump can be realized. The optimization problem consists in maximizing the daily pumped water quantity via the optimization of the motor efficiency for every operation point. The proposed structure allows at the same time the minimization the machine losses, the field oriented control and the maximum power tracking of the photovoltaic array. This will be attained based on multi-input and multi-output optimal regulator theory. The effectiveness of the proposed algorithm is described by simulation and the obtained results are compared to those of a system working with a constant air gap flux. (author)

Betka, A.; Attali, A. [Laboratoire de Genie Electrique de Biskra (LGEB), Electrical Engineering Department, University of Biskra (Algeria)

2010-07-15T23:59:59.000Z

227

Managing Uncertainty in Operational Control of Water Distribution Systems  

E-Print Network (OSTI)

Managing Uncertainty in Operational Control of Water Distribution Systems A. Bargiela Department. There are system management decisions concerning the regulatory measures such as water pricing principles, effluent in water distribution systems con- cern reservoir(s) management with associated pump scheduling

Bargiela, Andrzej

228

Optimized design of a heat exchanger for an air-to-water reversible heat pump working with propane (R290)  

E-Print Network (OSTI)

Optimized design of a heat exchanger for an air-to-water reversible heat pump working with propane-to-water reversible heat pump unit was carried out using two different fin-and-tube heat exchanger ``coil'' designs concepts. The performance of the heat pump was evaluated for each coil design at different superheat

Fernández de Córdoba, Pedro

229

Solar-assisted auto-cascade heat pump cycle with zeotropic mixture R32/R290 for small water heaters  

Science Journals Connector (OSTI)

Abstract In this study, a novel solar-assisted auto-cascade heat pump cycle (SAHPC) operating with the zeotropic mixture of R32/R290 for small water heaters is proposed. In the SAHPC system, a cascade heat exchanger (CHEX) associated with a phase separator is used to achieve auto cascade cycle and enhance the overall system performance. The performances of the SAHPC are evaluated by using the developed mathematical model, and then compared with the conventional air-sourced heat pump cycle (CAHPC). Simulation results show the SAHPC has 4.23–9.85% and 4.37–9.68% improvements in COP and volumetric heating capacity compared with those of the CAHPC, respectively, under the same operating conditions. However, the improvement of performance of this novel cycle largely depends on the absorbing heat ratio and the zeotropic composition. It is expected that this new cycle will be beneficial to developing dual-source coupled heat pump applications.

Xiaolong Lv; Gang Yan; Jianlin Yu

2015-01-01T23:59:59.000Z

230

Performance Analysis of Air-Source Variable Speed Heat Pumps and Various Electric Water Heating Options  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Analysis of Air- Analysis of Air- Source Variable Speed Heat Pumps and Various Electric Water Heating Options Jeffrey Munk Oak Ridge National Laboratory 2 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Acknowledgements * Tennessee Valley Authority - David Dinse * U.S. Department of Energy * Roderick Jackson * Tony Gehl * Philip Boudreaux * ZEBRAlliance 3 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Overview * Electric Water Heating Options - Conventional Electric Water Heaters - Heat Pump Water Heaters * Air-Source * Ground-Source - Solar Thermal Water Heater * Variable Speed Heat Pumps - Energy Use Analysis - Measured Performance - Operational Characteristics 4 Managed by UT-Battelle for the U.S. Department of Energy Presentation_name Water Heating Options

231

Offshore Floating Wind Turbine-driven Deep Sea Water Pumping for Combined Electrical Power and District Cooling  

Science Journals Connector (OSTI)

A new concept utilising floating wind turbines to exploit the low temperatures of deep sea water for space cooling in buildings is presented. The approach is based on offshore hydraulic wind turbines pumping pressurised deep sea water to a centralised plant consisting of a hydro-electric power system coupled to a large-scale sea water-cooled air conditioning (AC) unit of an urban district cooling network. In order to investigate the potential advantages of this new concept over conventional technologies, a simplified model for performance simulation of a vapour compression AC unit was applied independently to three different systems, with the AC unit operating with (1) a constant flow of sea surface water, (2) a constant flow of sea water consisting of a mixture of surface sea water and deep sea water delivered by a single offshore hydraulic wind turbine and (3) an intermittent flow of deep sea water pumped by a single offshore hydraulic wind turbine. The analysis was based on one year of wind and ambient temperature data for the Central Mediterranean that is known for its deep waters, warm climate and relatively low wind speeds. The study confirmed that while the present concept is less efficient than conventional turbines utilising grid-connected electrical generators, a significant portion of the losses associated with the hydraulic transmission through the pipeline are offset by the extraction of cool deep sea water which reduces the electricity consumption of urban air-conditioning units.

T Sant; D Buhagiar; R N Farrugia

2014-01-01T23:59:59.000Z

232

Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models: Preprint  

SciTech Connect

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. Laboratory results demonstrate the efficiency of this technology under most of the conditions tested and show that differences in control schemes and design features impact the performance of the individual units. These results were used to understand current model limitations, and then to bracket the energy savings potential for HPWH technology in various US climate regions. Simulation results show that HPWHs are expected to provide significant energy savings in many climate zones when compared to other types of water heaters (up to 64%, including impact on HVAC systems).

Hudon, K.; Sparn, B.; Christensen, D.; Maguire, J.

2012-02-01T23:59:59.000Z

233

Highly sensitive vacuum ion pump current measurement system  

DOE Patents (OSTI)

A vacuum system comprising: 1) an ion pump; 2) power supply; 3) a high voltage DC--DC converter drawing power from the power supply and powering the vacuum pump; 4) a feedback network comprising an ammeter circuit including an operational amplifier and a series of relay controlled scaling resistors of different resistance for detecting circuit feedback; 5) an optional power block section intermediate the power supply and the high voltage DC--DC converter; and 6) a microprocessor receiving feedback information from the feedback network, controlling which of the scaling resistors should be in the circuit and manipulating data from the feedback network to provide accurate vacuum measurement to an operator.

Hansknecht, John Christopher (Williamsburg, VA)

2006-02-21T23:59:59.000Z

234

Maintain Pumping Systems Effectively | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2005) More Documents & Publications Minimize Compressed Air Leaks Determining the Right Air Quality for Your Compressed Air System Effect of Intake on Compressor Performance...

235

Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade  

SciTech Connect

High initial cost and lack of public awareness of ground source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights findings of a case study of one of the ARRA-funded GSHP demonstration projects, which is a heating only central GSHP system using shallow aquifer as heat source and installed at a warehouse and truck bay at Kalispell, MT. This case study is based on the analysis of measured performance data, utility bills, and calculations of energy consumptions of conventional central heating systems for providing the same heat outputs as the central GSHP system did. The evaluated performance metrics include energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of GSHP system compared with conventional heating systems. This case study also identified areas for reducing uncertainties in performance evaluation, improving operational efficiency, and reducing installed cost of similar GSHP systems in the future. Publication of ASHRAE at the annual conference in Seattle.

Liu, Xiaobing [Oak Ridge National Lab] [Oak Ridge National Lab

2014-06-01T23:59:59.000Z

236

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet), NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

simulation model helps researchers evaluate real-world simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes. Heat pump water heaters (HPWHs) remove heat from the air and use it to heat water, presenting an energy-saving opportunity for homeowners. Researchers at the National Renewable Energy Laboratory (NREL) developed a simulation model to study the inter- actions of HPWHs and space conditioning equipment, related to climate and installa- tion location in the home. This model was created in TRNSYS and is based on data from HPWHs tested at NREL's Advanced HVAC Systems Laboratory. The HPWH model accounts for the condenser coil wrapped around the outside of the storage tank, and uses a data-based performance map. Researchers found that simulated energy use was within 2% of lab results, which confirms

237

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems  

SciTech Connect

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL

2011-01-01T23:59:59.000Z

238

A capital cost comparison of commercial ground-source heat pump systems  

SciTech Connect

The report provides a capital cost comparison of commercial ground source heat pump systems. The study includes groundwater systems, ground-coupled systems and hybrid systems.

Rafferty, K.

1994-06-01T23:59:59.000Z

239

Regional Variation in Residential Heat Pump Water Heater Performance in the United States  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Regional Variation in Residential Heat Pump Water Heater Performance in the US Jeff Maguire 4/30/13 Outline * Why HPWHs? * US Water Heating Market * Overview of HPWHs * Model Description * Results o HPWH Performance o Energy Savings Potential o Breakeven Cost 2 Heat Pump Water Heaters Save $300 a year over standard electric? Save $100 a year over standard gas? Heat Pump Electric Gas 3 Questions about HPWHs * Are HPWHs a good replacement for typical gas and electric storage water heaters? o In different locations across the country? o In conditioned/unconditioned space? o Source energy savings?

240

Ground Source Heat Pump System Data Analysis  

NLE Websites -- All DOE Office Websites (Extended Search)

Peer Review Peer Review GSHP System Data Analysis Xiaobing Liu, Ph.D. Oak Ridge National Laboratory liux2@ornl.gov (865-574-2593) 4/3/2013 - GSHP Data Analysis in 1 st phase of U.S.-China CERC-BEE - GSHP ARRA Grantee Data Mining 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: High first cost of ground heat exchangers (GHXs) and lack of knowledge/trust in achievable benefits are major barriers preventing

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Ground Source Heat Pump System Data Analysis  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Peer Review Peer Review GSHP System Data Analysis Xiaobing Liu, Ph.D. Oak Ridge National Laboratory liux2@ornl.gov (865-574-2593) 4/3/2013 - GSHP Data Analysis in 1 st phase of U.S.-China CERC-BEE - GSHP ARRA Grantee Data Mining 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: High first cost of ground heat exchangers (GHXs) and lack of knowledge/trust in achievable benefits are major barriers preventing

242

Experimental investigation on system with combination of ground-source heat pump and solar collector  

Science Journals Connector (OSTI)

This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by ...

Tao Hu ? ?; Jialing Zhu ???; Wei Zhang ? ?

2013-06-01T23:59:59.000Z

243

Application Prospect Analysis of the Surface Water Source Heat-Pump in China  

E-Print Network (OSTI)

Surface water resources in China are rather abundant and it can be use as the heat or cool source for heat pump. The winter surface water temperatures of 17 typical cities are investigated in December, and they are all distributed in the interval...

Zhang, C.; Zhuang, Z.; Huang, L.; Li, X.; Li, G.; Sun, D.

2006-01-01T23:59:59.000Z

244

Figure 1. Schematic of initial air pump design Design of Air Pump System Using Bond Graph  

E-Print Network (OSTI)

, is presented in Figure 1. It is a vibratory pump in which an electromagnetic circuit drives a small permanent magnet attached to a pivoted lever that, in turn, drives a rubber bellows pump. The bellows pump has of the cascaded arrangement of three coupled subsystems: the electromagnetic actuator, the lever, and the air

Fernandez, Thomas

245

Measured Space Conditioning and Water Heating Performance of a Ground-Source Integrated Heat Pump in a Residential Application  

SciTech Connect

In an effort to reduce residential building energy consumption, a ground-source integrated heat pump was developed to meet a home s entire space conditioning and water heating needs, while providing 50% energy savings relative to a baseline suite of minimum efficiency equipment. A prototype 7.0 kW system was installed in a 344 m2 research house with simulated occupancy in Oak Ridge, TN. The equipment was monitored from June 2012 through January 2013.

Munk, Jeffrey D [ORNL] [ORNL; Ally, Moonis Raza [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2014-01-01T23:59:59.000Z

246

Environmentally Friendly Systems: Earth Heat Pump System with Vertical Pipes for Heat Extraction for Domestic Heating and Cooling  

Science Journals Connector (OSTI)

Geothermal heat pumps (GSHPs), or direct expansion (DX) ground source heat pumps, are highly efficient renewable energy technology, ... the earth, groundwater or surface water as heat sources when operating in heating

Saffa Riffat; Siddig Omer; Abdeen Omer

2014-01-01T23:59:59.000Z

247

Ciliary pumping with arrays of ciliated tentacles is one of the most universal mechanisms of water movement used by  

E-Print Network (OSTI)

Ciliary pumping with arrays of ciliated tentacles is one of the most universal mechanisms of water echinoderms (Strathmann, 1973; Jørgensen, 1989; Hart, 1991, 1994). The effectiveness of ciliary pumping hydromechanical principles may govern the functional morphology of ciliary pumping across taxa. In each example

Grünbaum, Daniel

248

Building America Technology Solutions for New and Existing Homes: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a heat pump water heater in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

249

Method and system for homogenizing diode laser pump arrays  

DOE Patents (OSTI)

An optical amplifier system includes a diode pump array including a plurality of semiconductor diode laser bars disposed in an array configuration and characterized by a periodic distance between adjacent semiconductor diode laser bars. The periodic distance is measured in a first direction perpendicular to each of the plurality of semiconductor diode laser bars. The diode pump array provides a pump output propagating along an optical path and characterized by a first intensity profile measured as a function of the first direction and having a variation greater than 10%. The optical amplifier system also includes a diffractive optic disposed along the optical path. The diffractive optic includes a photo-thermo-refractive glass member. The optical amplifier system further includes an amplifier slab having an input face and position along the optical path and separated from the diffractive optic by a predetermined distance. A second intensity profile measured at the input face of the amplifier slab as a function of the first direction has a variation less than 10%.

Bayramian, Andy J

2013-10-01T23:59:59.000Z

250

Auto-Calibration and Control Strategy Determination for a Variable-Speed Heat Pump Water Heater Using Optimization  

SciTech Connect

This paper introduces applications of the GenOpt optimizer coupled with a vapor compression system model for auto-calibration and control strategy determination towards the development of a variable-speed ground-source heat pump water heating unit. The GenOpt optimizer can be linked with any simulation program using input and output text files. It effectively facilitates optimization runs. Using our GenOpt wrapper program, we can flexibly define objectives for optimizations, targets, and constraints. Those functionalities enable running extensive optimization cases for model calibration, configuration design and control strategy determination. In addition, we describe a methodology to improve prediction accuracy using functional calibration curves. Using the calibrated model, we investigated control strategies of the ground-source heat pump water heater, considering multiple control objectives, covering the entire operation range.

Shen, Bo [ORNL] [ORNL; Abdelaziz, Omar [ORNL] [ORNL; Rice, C Keith [ORNL] [ORNL

2012-01-01T23:59:59.000Z

251

New test methodologies to analyse direct expansion solar assisted heat pumps for domestic hot water  

Science Journals Connector (OSTI)

Abstract Since there are not specific standards for testing direct expansion solar assisted heat pumps for domestic hot water, new testing methodologies are proposed supported by laboratory experiments. Two methodologies were developed for performance measurement: modified BIN method and long term performance prediction with a TRNSYS model validated with specific experimental conditions. The long term performance prediction is a methodology similar to the already obtained for solar thermal systems. A system was tested in Lisbon during one year, covering almost all possible local weather conditions. The hot water tapping test cycle used was in agreement with recent standards EN16147:2011 or EN15316-3-1:2007. The influence of average daily air temperature, dew point temperature and solar irradiation was analysed. The seasonal performance factor was calculated for two cities in Portugal (Lisbon and Porto) and for additional four cities in Europe (Davos, Athens, Helsinki and Strasburg). The establishment of a procedure to calculate the seasonal performance of this kind of systems is very important according to the directive 2009/28/EC of the European Parliament and of the Council.

Jorge Facão; Maria João Carvalho

2014-01-01T23:59:59.000Z

252

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

as conventional electric resistance water heaters, with thetwo technologies: (1) an electric resistance storage watertransfers heat from the electric resistance element to the

Franco, Victor

2011-01-01T23:59:59.000Z

253

E-Print Network 3.0 - absorption-sorption heat pumps Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Corporation Auxiliary - Heat pump water heater 50... -gal tank, electric auxiliary heating Multiple operating modes: heat pump, hybrid and standard... and Ventilation Systems...

254

E-Print Network 3.0 - absorption-type heat pumps Sample Search...  

NLE Websites -- All DOE Office Websites (Extended Search)

Corporation Auxiliary - Heat pump water heater 50... -gal tank, electric auxiliary heating Multiple operating modes: heat pump, hybrid and standard... and Ventilation Systems...

255

Exergy and Energy analysis of a ground-source heat pump for domestic water heating under simulated occupancy conditions  

SciTech Connect

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

Ally, Moonis Raza [ORNL; Munk, Jeffrey D [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL

2012-01-01T23:59:59.000Z

256

Ultra high vacuum pumping system and high sensitivity helium leak detector  

DOE Patents (OSTI)

An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10.sup.-13 atm cc s.sup.-1. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces backstreaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium.

Myneni, Ganapati Rao (Yorktown, VA)

1997-01-01T23:59:59.000Z

257

Ultra high vacuum pumping system and high sensitivity helium leak detector  

DOE Patents (OSTI)

An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10{sup {minus}13} atm cc/s. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces back streaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium. 2 figs.

Myneni, G.R.

1997-12-30T23:59:59.000Z

258

PERFORMANCE ANALYSIS OF A RESIDENTIAL GROUND SOURCE HEAT PUMP SYSTEM WITH ANTIFREEZE SOLUTION  

E-Print Network (OSTI)

PERFORMANCE ANALYSIS OF A RESIDENTIAL GROUND SOURCE HEAT PUMP SYSTEM WITH ANTIFREEZE SOLUTION M in a ground source heat pump system falls near or below 0o C, an antifreeze mixture must be used to prevent freezing in the heat pump. The antifreeze mixture type and concentration has a number of implications

259

Efficiency improvement of a ground coupled heat pump system from energy management  

E-Print Network (OSTI)

Efficiency improvement of a ground coupled heat pump system from energy management N. Pardo a,*, Á coupled heat pump Energy efficiency Numerical simulation a b s t r a c t The installed capacity of an air to improve the efficiency of a ground coupled heat pump air conditioning system by adapting its produced

Fernández de Córdoba, Pedro

260

Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade  

Energy.gov (U.S. Department of Energy (DOE))

Project Will Take Advantage of Abundant Water in Shallow Aquifer. Demonstrate Low Temperature GSHP System Design. Provides a Baseline for Local Industrial Geothermal Project Costs and Benefits.

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

System Modeling of Gas Engine Driven Heat Pump  

SciTech Connect

To improve the system performance of the GHP, modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated by using ORNL Modulating Heat Pump Design Software, which is used to predict steady-state heating and cooling performance of variable-speed vapor compression air-to-air heat pumps for a wide range of operational variables. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using desiccant system regenerated by waste heat from engine, the SHR can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% in rated operating conditions.

Mahderekal, Isaac [Oak Ridge National Laboratory (ORNL)] [Oak Ridge National Laboratory (ORNL); Shen, Bo [ORNL] [ORNL; Vineyard, Edward [Oak Ridge National Laboratory (ORNL)] [Oak Ridge National Laboratory (ORNL)

2012-01-01T23:59:59.000Z

262

Reactor water cleanup system  

DOE Patents (OSTI)

A reactor water cleanup system includes a reactor pressure vessel containing a reactor core submerged in reactor water. First and second parallel cleanup trains are provided for extracting portions of the reactor water from the pressure vessel, cleaning the extracted water, and returning the cleaned water to the pressure vessel. Each of the cleanup trains includes a heat exchanger for cooling the reactor water, and a cleaner for cleaning the cooled reactor water. A return line is disposed between the cleaner and the pressure vessel for channeling the cleaned water thereto in a first mode of operation. A portion of the cooled water is bypassed around the cleaner during a second mode of operation and returned through the pressure vessel for shutdown cooling.

Gluntz, Douglas M. (San Jose, CA); Taft, William E. (Los Gatos, CA)

1994-01-01T23:59:59.000Z

263

Reactor water cleanup system  

DOE Patents (OSTI)

A reactor water cleanup system includes a reactor pressure vessel containing a reactor core submerged in reactor water. First and second parallel cleanup trains are provided for extracting portions of the reactor water from the pressure vessel, cleaning the extracted water, and returning the cleaned water to the pressure vessel. Each of the cleanup trains includes a heat exchanger for cooling the reactor water, and a cleaner for cleaning the cooled reactor water. A return line is disposed between the cleaner and the pressure vessel for channeling the cleaned water thereto in a first mode of operation. A portion of the cooled water is bypassed around the cleaner during a second mode of operation and returned through the pressure vessel for shutdown cooling. 1 figure.

Gluntz, D.M.; Taft, W.E.

1994-12-20T23:59:59.000Z

264

Heat pump water heater and storage tank assembly  

DOE Patents (OSTI)

A water heater and storage tank assembly comprises a housing defining a chamber, an inlet for admitting cold water to the chamber, and an outlet for permitting flow of hot water from the chamber. A compressor is mounted on the housing and is removed from the chamber. A condenser comprises a tube adapted to receive refrigerant from the compressor, and winding around the chamber to impart heat to water in the chamber. An evaporator is mounted on the housing and removed from the chamber, the evaporator being adapted to receive refrigerant from the condenser and to discharge refrigerant to conduits in communication with the compressor. An electric resistance element extends into the chamber, and a thermostat is disposed in the chamber and is operative to sense water temperature and to actuate the resistance element upon the water temperature dropping to a selected level. The assembly includes a first connection at an external end of the inlet, a second connection at an external end of the outlet, and a third connection for connecting the resistance element, compressor and evaporator to an electrical power source.

Dieckmann, John T. (Belmont, MA); Nowicki, Brian J. (Watertown, MA); Teagan, W. Peter (Acton, MA); Zogg, Robert (Belmont, MA)

1999-09-07T23:59:59.000Z

265

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Performance of a Performance of a Heat Pump Water Heater in the Hot-Humid Climate Windermere, Florida Over recent years, heat pump water heaters (HPWHs) have become more read- ily available and more widely adopted in the marketplace. A key feature of an HPWH unit is that it is a hybrid system. When conditions are favorable, the unit will operate in heat pump mode (using a vapor compression system that extracts heat from the surrounding air) to efficiently provide domestic hot water (DHW). Homeowners need not adjust their behavior to conform to the heat pump's capabilities. If a heat pump cannot meet a higher water draw demand, the heater will switch to electric resistance to provide a higher heating rate. This flexibility

266

The Coordinated Control of a Central Air Conditioning System Based on Variable Chilled Water Temperature and Variable Chilled Water Flow  

E-Print Network (OSTI)

At present, regulation of water flow by means of pump frequency conversion is one of the major methods for power-saving in central air conditioning systems. In this article, optimization regulation for central air conditioning system on the basis...

Liu, J.; Mai, Y.; Liu, X.

2006-01-01T23:59:59.000Z

267

Optimization of Advanced Ground-Coupled Heat Pump Systems A heat pump is a technology in which heating and cooling are provided by a single piece of equipment.  

E-Print Network (OSTI)

Optimization of Advanced Ground-Coupled Heat Pump Systems A heat pump is a technology in which heating and cooling are provided by a single piece of equipment. In a Ground Coupled Heat Pump (GCHP) system a length of pipe is buried in the ground and the ground acts as a reservoir to store the heat

Wisconsin at Madison, University of

268

Pilot study of commercial water-loop heat pump compressor life  

SciTech Connect

This study of the service life of water-loop heat pump compressors in commercial office buildings, using data gathered from the service records of one heat pump service contractor, focused on the replacement of compressors in small console ( perimeter'') water-loop heat pumps and in larger vertical and horizontal ( core'') units. A statistical methodology for dealing with censored data was developed for this study which is an extension of the methodologies used in other EPRI studies of heat pump and heat pump compressor life. By extrapolating a Weibull distribution curve fitted to the data, the median service life of the sample of perimeter unit compressors (the age at which 50% of the original population of compressors would be expected to have been replaced) was estimated to be 47 years. The median service life of a sample that excluded compressors with a known manufacturing defect was estimated to be 69 years. Core unit compressor replacements were analyzed in the same manner. Extrapolation of a Weibull distribution yielded an estimated median service life of core unit compressors of 12 years. As with the perimeter unit compressors, there was an identified manufacturing defect. When the compressors with the identified fault were excluded from the sample and the data reanalyzed, the median service life for the compressors in the remainder of the buildings was estimated to be 18 years.

Ross, D.P. (Policy Research Associates, Inc., Reston, VA (USA))

1990-03-01T23:59:59.000Z

269

Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort  

SciTech Connect

Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes’ space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

2014-07-21T23:59:59.000Z

270

Graded pitch electromagnetic pump for thin strip metal casting systems  

DOE Patents (OSTI)

A metal strip casing system is provided with an electromagnetic pump which includes a pair of primary blocks having a graded pole pitch, polyphase ac winding and being arranged on opposite sides of a movable heat sink. A nozzle is provided for depositing liquid metal on the heat sink such that the resulting metal strip and heat sink combination is subjected to a longitudinal electromagnetic field which increases in wavelength in the direction of travel of the heat sink, thereby subjecting the metal and heat sink to a longitudinal force having a magnitude which increases in the direction of travel. 4 figs.

Kuznetsov, S.B.

1986-04-01T23:59:59.000Z

271

Computer system design description for the spare pump mini-dacs data acquisition and control system  

SciTech Connect

The attached document outlines the computer software design for the mini data acquisition and control system (DACS), that supports the testing of the spare pump for Tank 241-SY-101, at the maintenance and storage facility (MASF).

Vargo, G.F. Jr.

1994-09-29T23:59:59.000Z

272

GROUND-COUPLED HEAT-PUMP-SYSTEM EXPERIMENTAL RESULTS* Philip D. Metz  

E-Print Network (OSTI)

#12;GROUND-COUPLED HEAT-PUMP-SYSTEM EXPERIMENTAL RESULTS* Philip D. Metz _Solar and Renewables house in Upton, Long Island, New York has been heated and cooled by a liquid source heat pump using- saving construction with a heating load of 7.8 X 106 J/OC-day (4.1 X 103 Btu/ OF-day). The heat pump used

Oak Ridge National Laboratory

273

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 15, NO. 3, JUNE 2006 717 Electroosmotic Pumps Fabricated From Porous  

E-Print Network (OSTI)

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 15, NO. 3, JUNE 2006 717 Electroosmotic Pumps electroos- motic pumps with high flow rates per applied potential difference. The porosity and pore size of the polysilicon layer, resulting in a pore radius varying from 1 to 3 m. Pumping performance of these devices

Santiago, Juan G.

274

Pumping fluids in microfluidic systems using the elastic deformation of poly(dimethylsiloxane){  

E-Print Network (OSTI)

Pumping fluids in microfluidic systems using the elastic deformation of polyth October 2007 DOI: 10.1039/b714664g This paper demonstrates a methodology for storing and pumping. Introduction This note describes a technique for storing and pumping fluids in microfluidic devices fabricated

Prentiss, Mara

275

Failure and Reliability Analysis for the Master Pump Shutdown System  

SciTech Connect

The Master Pump Shutdown System (MPSS) will be installed in the 200 Areas of the Hanford Site to monitor and control the transfer of liquid waste between tank farms and between the 200 West and 200 East areas through the Cross-Site Transfer Line. The Safety Function provided by the MPSS is to shutdown any waste transfer process within or between tank farms if a waste leak should occur along the selected transfer route. The MPSS, which provides this Safety Class Function, is composed of Programmable Logic Controllers (PLCs), interconnecting wires, relays, Human to Machine Interfaces (HMI), and software. These components are defined as providing a Safety Class Function and will be designated in this report as MPSS/PLC. Input signals to the MPSS/PLC are provided by leak detection systems from each of the tank farm leak detector locations along the waste transfer route. The combination of the MPSS/PLC, leak detection system, and transfer pump controller system will be referred to as MPSS/SYS. The components addressed in this analysis are associated with the MPSS/SYS. The purpose of this failure and reliability analysis is to address the following design issues of the Project Development Specification (PDS) for the MPSS/SYS (HNF 2000a): (1) Single Component Failure Criterion, (2) System Status Upon Loss of Electrical Power, (3) Physical Separation of Safety Class cables, (4) Physical Isolation of Safety Class Wiring from General Service Wiring, and (5) Meeting the MPSS/PLC Option 1b (RPP 1999) Reliability estimate. The failure and reliability analysis examined the system on a component level basis and identified any hardware or software elements that could fail and/or prevent the system from performing its intended safety function.

BEVINS, R.R.

2000-09-05T23:59:59.000Z

276

Pressure pulsations in reciprocating pump piping systems Part 1: Modelling  

E-Print Network (OSTI)

A distributed parameter model of pipeline transmission line behaviour is presented, based on a Galerkin method incorporating frequency-dependent friction. This is readily interfaced to an existing model of the pumping dynamics of a plunger pump to allow time-domain simulations of pipeline pressure pulsations in both suction and delivery lines. A new model for the pump inlet manifold is also proposed.

Shu, Jian-Jun; Edge, Kevin A

2014-01-01T23:59:59.000Z

277

Energy Audit of a Water System Network  

Science Journals Connector (OSTI)

The energy audit of water networks has to be focused... i - Operational schedule of pumping stations and available storage to atte...

Edmundo Koelle

1995-01-01T23:59:59.000Z

278

Building America Technology Solutions for New and Existing Homes: Air-to-Water Heat Pumps with Radiant Delivery in Low Load Homes (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

Researchers from Alliance for Residential Building Initiative worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation.

279

Analysis of solar desalination system using heat pump  

Science Journals Connector (OSTI)

Abstract This paper investigates a pilot desalination system which consists of a direct expansion solar assisted heat pump (DXSAHP) coupled to a single-effect evaporator unit. The working fluid used is \\{R134a\\} and distillate is obtained via falling film evaporation and flashing in the unit. Experiments have been conducted in both day and night meteorological conditions in Singapore and the effects of solar irradiation and compressor speed have been studied against the system performance. From the experiments, the Performance Ratio (PR) obtained ranges from 0.43 to 0.88, the average Coefficient of Performance (COP) was 8 and the highest distillate production recorded was 1.38 kg/h.

Zakaria Mohd Amin; M.N.A. Hawlader

2015-01-01T23:59:59.000Z

280

Pump Selection Considerations  

Energy.gov (U.S. Department of Energy (DOE))

This tip sheet outlines important pump selection considerations, including fluid properties and pumping system end use requirements.

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Study of Low Global Warming Potential Refrigerants in Heat Pump System for Residential Applications.  

E-Print Network (OSTI)

??R410A is one of the major refrigerants used for air conditioning and heat pump systems in residential applications. It has zero ODP but its GWP… (more)

Barve, Atharva

2012-01-01T23:59:59.000Z

282

Heat pump systems and their costs from the perspective of insurance companies, users and environment.  

E-Print Network (OSTI)

?? This report is based on a project which aims to evaluate the costs for the heat pump system from the perspective of Swedish insurance… (more)

Trang, Leon

2014-01-01T23:59:59.000Z

283

Problems of improving the methods of technicoeconomic substantiation of pumped-storage stations in power systems  

Science Journals Connector (OSTI)

The method of substantiating pumped-storage stations requires further development and perfection toward a more complete consideration of their system effect.

V. S. Sharygin

1981-02-01T23:59:59.000Z

284

Performance of Heat Pump Water Heaters: Initial Findings of Draw Profile Effect on HPWH Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Performance of Heat Pump Water Heaters Performance of Heat Pump Water Heaters © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved. Evaluation Overview  2000-2002 Evaluated 20 installations with CL&P  Product had problems; not ready for prime time (average COPs of 1.67 was not the problem)  New batch of heaters available, including:  GE's GeoSpring Hybrid (50 gal)  A.O.Smith's Voltex Hybrid (60 & 80 gal)  Stiebel-Eltron's Accelera 300 (80 gal)  Evaluating 14 installations for National Grid, NSTAR, & Cape Light Compact. © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved.

285

Infrared Pump–Probe Study of Nanoconfined Water Structure in Reverse Micelle  

Science Journals Connector (OSTI)

In the cases of the HN3 molecules in bulk water as well as in large RMs, the azido IR PP signal does not completely decay to zero due to the local heating contribution to the PP signal. ... This libration decay rate is consistent with the results of previous IR pump-probe measurement analyses for the appearance of heat following excitation resonant with the bend or stretch fundamentals. ...

Jooyong Lee; Micha? Maj; Kyungwon Kwak; Minhaeng Cho

2014-09-19T23:59:59.000Z

286

Energy Saving Pumping Systems in Chemical Plant Design  

E-Print Network (OSTI)

column without proper regard to the calandria circulating pump's net positive suction head (NPSH) requirements. The column designer will always want to keep the skirt height to an absolute minimum to save on steel and piping costs. Also, he seldom... has adequate appreciation of the centrifugal pump's requirements. The process or project design engineer has the prime responsibility to provide for adequate NPSH. He can accomplish this by consulting: (1) with a pump application engineer, either...

Reynolds, J. A.

1980-01-01T23:59:59.000Z

287

Chapter 9 - Hydraulic pumping  

Science Journals Connector (OSTI)

Publisher Summary The hydraulic pumping system takes liquid (water or oil) from a liquid reservoir on the surface, puts it through a reciprocating multiplex piston pump or horizontal electrical submersible pump to increase the pressure, and then injects the pressurized liquid (power fluid) down-hole through a tubing string. At the bottom of the injection tubing string, the power fluid is directed into the nozzle of a jet pump or to the hydraulic engine of a piston pump, both of which have been set well below the producing fluid level. The surface injection pressures normally range from approximately 2000 psi up to 4000 psi, with some going up to but rarely above 4500 psi. An electric motor, diesel engine, or gas engine is used to drive the multiplex pump. The fundamental operating principle of subsurface hydraulic pumps is Pascal's Law, postulated by Blaise Pascal in 1653. This principle makes it possible to transmit pressure from the surface by means of a liquid-filled tubing string to any given point below the surface. The chapter further highlights applications to dewatering wells-gas and coal bed methane, limitations of other forms of lift, advantages of hydraulic pumping, disadvantages of hydraulic pumping, and different types of operating systems.

James F. Lea; Henry V. Nickens; Mike R. Wells

2008-01-01T23:59:59.000Z

288

Investigations of novel heat pump systems for low carbon homes.  

E-Print Network (OSTI)

??The European standard EN15450 states that the Coefficient of Performance (COP) target range for a Ground Source Heat Pump (GSHP) installation should lie within the… (more)

Mempouo, B.

2011-01-01T23:59:59.000Z

289

Performance Analysis of a Transcritical CO2 Heat Pump Water Heater Incorporating a Brazed-Plate Gas-cooler.  

E-Print Network (OSTI)

??This study focuses on the experimental testing and numerical modeling of a 4.5 kW transcritical CO2 heat pump water heater at Queen’s University in the… (more)

Murray, PORTIA

2015-01-01T23:59:59.000Z

290

Experimental study of a photovoltaic solar-assisted heat-pump/heat-pipe system  

Science Journals Connector (OSTI)

A practical design for a heat pump with heat-pipe photovoltaic/thermal (PV/T) collectors is presented. The hybrid system is called the photovoltaic solar-assisted heat-pump/heat-pipe (PV-SAHP/HP) system. To focus on both actual demand and energy savings, the PV-SAHP/HP system was designed to be capable of operating in three different modes, namely, the heat-pipe, solar-assisted heat pump, and air-source heat-pump modes. Based on solar radiation, the system operates in an optimal mode. A series of experiments were conducted in Hong Kong to study the performance of the system when operating in the heat-pipe and the solar-assisted heat-pump modes. Moreover, energy and exergy analyses were used to investigate the total PV/T performance of the system.

H.D. Fu; G. Pei; J. Ji; H. Long; T. Zhang; T.T. Chow

2012-01-01T23:59:59.000Z

291

Survey of hybrid solar heat pump drying systems  

Science Journals Connector (OSTI)

Solar drying is in practice since the ancient time for preservation of food and agriculture crops. The objective of most drying processes is to reduce the moisture content of the product to a specified value. Solar dryers used in agriculture for food ... Keywords: coefficient of performance (COP), direct expansion SAHD, drying chamber, heat pump, solar assisted heat pumps dryer (SAHPD), solar fraction

R. Daghigh; K. Sopian; M. H. Ruslan; M. A. Alghoul; C. H. Lim; S. Mat; B. Ali; M. Yahya; A. Zaharim; M. Y. Sulaiman

2009-02-01T23:59:59.000Z

292

Optimal Scheduling and Control of a Multi-Pump Boosting System Zhenyu Yang and Hakon Brsting  

E-Print Network (OSTI)

a significant impact on the energy consumption of entire pump associated systems. For instance, the energy Abstract-- An optimal scheduling and control method for a multiple pump system is proposed from the energy, refrigeration, sewage treatment, oil and gas pipeline transportation, marine relevant services etc.. Today over

Yang, Zhenyu

293

Absorption free superluminal light propagation in a three level pump-probe system  

E-Print Network (OSTI)

We investigate the dispersion and the absorption properties of a weak probe field in a three-level pump-probe atomic system. It is shown that the slope of dispersion changes from positive to negative just with the intensity of the coherent or indirect incoherent pumping fields. It is demonstrated that the absorption free superluminal light propagation is appeared in this system.

M. Mahmoudi; S. Worya Rabiei; L. Ebrahimi Zohravi; M. Sahrai

2007-11-21T23:59:59.000Z

294

Alternate Water Supply System  

Office of Legacy Management (LM)

Alternate Water Supply Alternate Water Supply System Flushing Report Riverton, Wyoming, Processing Site January 2008 Office of Legacy Management DOE M/1570 2008 - -L Work Performed Under DOE Contract No. for the U.S. Department of Energy Office of Legacy Management. DE-AC01-02GJ79491 Approved for public release; distribution is unlimited. Office of Legacy Management Office of Legacy Management Office of Legacy Management U.S. Department of Energy This page intentionally left blank DOE-LM/1570-2008 Alternate Water Supply System Flushing Report Riverton, Wyoming, Processing Site January 2008 Work Performed by S.M. Stoller Corporation under DOE Contract No. DE-AC01-02GJ79491 for the U.S. Department of Energy Office of Legacy Management, Grand Junction, Colorado This page intentionally left blank

295

Method for eliminating gas blocking in electrokinetic pumping systems  

DOE Patents (OSTI)

A method for eliminating gas bubble blockage of current flow during operation of an electrokinetic pump. By making use of the ability to modify the surface charge on the porous dielectric medium used in electrokinetic pumps, it becomes possible to place electrodes away from the pressurized region of the electrokinetic pump. While gas is still generated at the electrodes they are situated such that the generated gas can escape into a larger buffer reservoir and not into the high pressure region of the pump where the gas bubbles can interrupt current flow. Various combinations of porous dielectric materials and ionic conductors can be used to create pumps that have desirable electrical, material handling, and flow attributes.

Arnold, Don W. (Livermore, CA); Paul, Phillip H. (Livermore, CA); Schoeniger, Joseph S. (Oakland, CA)

2001-09-11T23:59:59.000Z

296

Effect of motor vibration problem on the power quality of water pumping stations  

Science Journals Connector (OSTI)

Abstract In this paper the effect of motor vibration problems on the dynamic performance and electrical power quality of water pumping stations is studied. A pump unit was tested for a full load and no load operating conditions. The dynamic results indicated that there is a problem of looseness in the motor base plate. The measurements were repeated again after achieving good support to the motor on its base plate. The results indicated that the vibration level decreased about 48% due to good support. The electrical power quality analysis showed that; the total harmonic distortion (THD) increases by about 1–2% due to the effect of bad motor vibration, and the 5th and 7th harmonic contents also increased by about 0.5–1.0%. Also the bad motor vibration caused large values of instantaneous flicker. These results indicated that the bad motor support causes many dynamics troubles and causes some power quality problems for the electrical feeder.

Khaled Fetyan; Dalia El_Gazzar

2014-01-01T23:59:59.000Z

297

Simulation study on supply temperature optimization in domestic heat pump systems  

Science Journals Connector (OSTI)

An air-to-water heat pump system for the heating of a one-family home is numerically analysed. The influence of the supply temperature on the seasonal performance factor of the heating system is examined by varying the heating curve. Furthermore, an adaptive control algorithm is studied which lowers the supply temperature according to the actual heating demand. The study includes a variation of control parameters. The different configurations are evaluated with respect to their efficiency (seasonal performance factor) and the comfort (room temperature). In systems with correctly parametrized heating curve controlling the room temperature is likely to be too high because of inner loads and solar gains. Instead of dealing with these gains by lowering the mass flow using thermostatic valves, the supply temperature can be dropped. This has a positive effect on heat pump efficiency because it decreases the total temperature lift. The control algorithm adapts the supply temperature in discrete time steps depending on the position of the thermostatic valve. Special attention has to be paid for the resulting room temperature and its deviation. With the control algorithm presented in this paper, the seasonal performance factor can be increased by up to 0.19, depending on the allowed variability of room temperature. Savings in annual primary energy demand compared to a standard controlling are up to 6.8%.

K. Huchtemann; D. Müller

2013-01-01T23:59:59.000Z

298

Review of solar assisted heat pump drying systems for agricultural and marine products  

Science Journals Connector (OSTI)

Combining solar energy and heat pump technology is a very attractive concept. It is able to eliminate some difficulties and disadvantages of using solar dryer systems or solely using heat pump drying separately. Solar assisted heat pump drying systems have been studied and applied since the last decades in order to increase the quality of products where low temperature and well-controlled drying conditions are needed. This paper reviewed studies on the advances in solar heat pump drying systems. Results and observation from the studies of solar assisted heat pump dryer systems indicated that for heat sensitive materials; improved quality control, reduced energy consumption, high coefficient of performance and high thermal efficiency of the dryer were achieved. The way forward and future directions in R&D in this field are further research regarding theoretical and experimental analysis as well as for the replacement of conventional solar dryer or heat pump dryer with solar assisted heat pump drying systems and solar assisted chemical and ground source heat pump dryers which should present energy efficient applications of the technologies.

Ronak Daghigh; Mohd Hafidz Ruslan; Mohamad Yusof Sulaiman; Kamaruzzaman Sopian

2010-01-01T23:59:59.000Z

299

Experimental performance analysis of a solar assisted ground source heat pump system under different heating operation modes  

Science Journals Connector (OSTI)

Abstract This paper presents an experimental study on the influence of operation modes on the heating performance of a solar assisted ground source heat pump system (SAGSHPS). Through experiments conducted in January, the characteristics of the SAGSHPS were investigated under different heating operation modes. The results indicate that the solar thermal could be used to accelerate the soil recovery when the heat pump unit is turned off, but the duration of solar use to recharge boreholes should be optimized according to the water temperature in the solar heat storage water tank to avoid unnecessary power consumption of the circulation pump. In addition, the solar heat storage water tank is beneficial for the stable operation of the SAGSHPS. The volumetric flow rate in the water tank has a significant impact on the electricity consumption of the SAGSHPS. From comprehensive analysis of the integral effect of the SAGSHPS under different modes, the mode in which the water tank is connected with the ground heat exchangers (GHES) in series is the recommended mode for the SAGSHPS in the coldest month in Dalian.

Lanhua Dai; Sufen Li; Lin DuanMu; Xiangli Li; Yan Shang; Ming Dong

2015-01-01T23:59:59.000Z

300

The Design of Ground-Coupled Heat Pump Systems  

E-Print Network (OSTI)

Ground-coupled heat pumps are being installed in increasing numbers due to proven performance and economy. The overall thermal resistance between the ground coupling fluid and a given type of surrounding soil is affected by pipe material, wall...

Parker, J. D.

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Economical Aspects of Adjustable Speed Drives in Pumping Systems  

E-Print Network (OSTI)

Speed variations of pumps have become increasingly popular as the technology to produce variable frequency drives has progressed. Variable speed drives have many advantages compared to throttle valves when it comes to regulation of flow. They offer...

Hovstadius, G.

302

Combined Operation of Solar Energy Source Heat Pump, Low-vale Electricity and Floor Radiant System  

E-Print Network (OSTI)

solar energy, low-vale electricity as heat sources in a floor radiant system are analyzed. This paper presents a new heat pump system and discusses its operational modes in winter....

Liu, G.; Guo, Z.; Hu, S.

2006-01-01T23:59:59.000Z

303

Energy Consumption Simulation and Analysis of Heat Pump Air Conditioning System in Wuhan by the BIN Method  

E-Print Network (OSTI)

to simulate the annual energy consumption of groundwater heat pump systems (GWHPS) for an office building in Wuhan. Its annual energy consumption was obtained and compared with the partner of the air source heat pump systems (ASHPS). The results show...

Wen, Y.; Zhao, F.

2006-01-01T23:59:59.000Z

304

Best Practices for Energy Efficient Cleanrooms: Variable Speed Pumping  

E-Print Network (OSTI)

efficiency of chilled water and condenser pumps, along with chiller efficiency and cooling tower efficiency, operate, and control water-pumping systems to achieve high efficiency and to lower life-cycle costsLBNL-58637 Best Practices for Energy Efficient Cleanrooms: Variable Speed Pumping Tengfang Xu June

305

SYSTEM PERFORMANCE OF A STIRLING ENGINE POWERED HEAT ACTIVATED HEAT PUMP  

E-Print Network (OSTI)

AUG 1979 SYSTEM PERFORMANCE OF A STIRLING ENGINE POWERED HEAT ACTIVATED HEAT PUMP W. D. Richards W The development of the first prototype heat activated heat pump (HAHP) jointly sponsored by the Gas Research as a unitary heating and cooling product competing for the same market as is currently served by the gas year

Oak Ridge National Laboratory

306

Geothermal Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Geothermal Heat Pumps Geothermal Heat Pumps Geothermal Heat Pumps June 24, 2012 - 5:08pm Addthis Watch how geothermal heat pumps heat and cool buildings by concentrating the naturally existing heat contained within the earth -- a clean, reliable, and renewable source of energy. How does it work? A geothermal heat pump uses the constant below ground temperature of soil or water to heat and cool your home. Geothermal heat pumps (GHPs), sometimes referred to as GeoExchange, earth-coupled, ground-source, or water-source heat pumps, have been in use since the late 1940s. They use the constant temperature of the earth as the exchange medium instead of the outside air temperature. This allows the system to reach fairly high efficiencies (300% to 600%) on the coldest winter nights, compared to 175% to 250% for air-source heat pumps on cool

307

OPTIMIZATION OF HYBRID GEOTHERMAL HEAT PUMP SYSTEMS Scott Hackel, Graduate Research Assistant; Gregory Nellis, Professor; Sanford Klein,  

E-Print Network (OSTI)

1 OPTIMIZATION OF HYBRID GEOTHERMAL HEAT PUMP SYSTEMS Scott Hackel, Graduate Research Assistant, Madison, WI, United States Abstract: Hybrid ground-coupled heat pump systems (HyGCHPs) couple conventional ground- coupled heat pump (GCHP) equipment with supplemental heat rejection or extraction systems

Wisconsin at Madison, University of

308

Improvement of photovoltaic pumping systems based on standard frequency converters by means of programmable logic controllers  

SciTech Connect

Photovoltaic pumping systems (PVPS) based on standard frequency converters (SFCs) are currently experiencing a growing interest in pumping programmes implemented in remote areas because of their high performance in terms of component reliability, low cost, high power range and good availability of components virtually anywhere in the world. However, in practical applications there have appeared a number of problems related to the adaptation of the SFCs to the requirements of the photovoltaic pumping systems (PVPS). Another disadvantage of dedicated PVPS is the difficulty in implementing maximum power point tracking (MPPT). This paper shows that these problems can be solved through the addition of a basic industrial programmable logic controller (PLC) to the system. This PLC does not increase the cost and complexity of the system, but improves the adaptation of the SFC to the photovoltaic pumping system, and increases the overall performance of the system. (author)

Fernandez-Ramos, Jose [Departamento de Electronica, Universidad de Malaga, Complejo Tecnologico de Teatinos (2.2.39), 29071 Malaga (Spain); Narvarte-Fernandez, Luis; Poza-Saura, Fernando [Instituto de Energia Solar, Universidad Politecnica de Madrid (IES-UPM), Avenida Complutense s/n (204), 28040 Madrid (Spain)

2010-01-15T23:59:59.000Z

309

Field Performance of Heat Pump Water Heaters in the Northeast, Massachusetts and Rhode Island (Fact Sheet)  

SciTech Connect

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring, A.O. Smith Voltex, and Stiebel Eltron Accelera 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

Not Available

2013-12-01T23:59:59.000Z

310

Analysis of recoverable waste heat of circulating cooling water in hot-stamping power system  

Science Journals Connector (OSTI)

This article studies the possibility of using heat pump instead of cooling tower to decrease temperature and recover waste heat of circulating cooling water of power system. Making use of heat transfer theory ......

Panpan Qin; Hui Chen; Lili Chen; Chong Wang…

2013-08-01T23:59:59.000Z

311

Heat Pump Market in Thailand  

Science Journals Connector (OSTI)

The value of hot water system in Thailand, rarely mentioned or quantified, is almost 3,000 million Baht per year. The heat pump is an option of hot water system. The development of heat pump in Thailand is officially started in 2002 according to the program of subsidy for heat pump but before that there was some slow development. Comparing to the cost of hot water production from instantaneous system, local manufactured heat pump is commercial viable even without the subsidy. The imported heat pump compared to local production can be sold to only high end user or high awareness of energy. The important factor of heat pump development is depended on the selling price, performance, and the customer behavior. The highest efficiency may not be the winner in Thai market as the drivers for higher efficiency or co-efficiency of performance of heat pump is not so strong compared to the price. Some of information in this paper cannot be supported by the real data because of the brand name of heat pump cannot be published.

Kuaanan Techato

2012-01-01T23:59:59.000Z

312

System analysis of membrane facilitated water generation from air humidity  

Science Journals Connector (OSTI)

Abstract The use of water vapor selective membranes can reduce the energy requirement for extracting water out of humid air by more than 50%. We performed a system analysis of a proposed unit, that uses membranes to separate water vapor from other atmospheric gases. This concentrated vapor can then be condensed specifically, rather than cooling the whole body of air. The driving force for the membrane permeation is maintained with a condenser and a vacuum pump. The pump regulates the total permeate side pressure by removing non-condensable gases that leak into the system. We show that by introducing a low-pressure, recirculated, sweep stream, the total permeate side pressure can be increased without impairing the water vapor permeation. This measure allows energy efficiency even in the presence of leakages, as it significantly lowers the power requirements of the vacuum pump. Such a constructed atmospheric water generator with a power of 62 kW could produce 9.19 m3/day of water (583 MJ/m3) as compared to 4.45 m3/day (1202 MJ/m3) that can be condensed without membranes. Due to the physical barrier the membrane imposes, fresh water generated in this manner is also cleaner and of higher quality than water condensed directly out of the air.

D. Bergmair; S.J. Metz; H.C. de Lange; A.A. van Steenhoven

2014-01-01T23:59:59.000Z

313

Solar pumping installation for pumping liquid and solar collector construction  

SciTech Connect

A solar pumping system, comprises, a pumping housing which defines a pump chamber therein which is adapted to be positioned in the ground below ground water level. Displacer means in the form of, for example, a bladder, arranged within the pump chamber, is capable of displacing liquid out of the pump chamber in response to a pressurized medium acting thereon to expel the water out of the chamber and up to a level above the ground for use. A suction valve connected into the chamber permits the ground water to flow into the chamber and a discharge valve connected out of the chamber permits the outflow of the ground water during the action of the displacer means. The construction includes a solar collector having at least one hydride conduit which is adapted to be exposed to the sun for solar heating to act on the hydride to cause hydrogen to be formed, the pressure of which acts against the displacer means to displace the ground liquid out of the pump chamber. When the solar collector is shielded and the hydride is permitted to cool or is cooled rapidly by the circulation of water thereover, the pressure of the generated hydrogen decreases, permitting ground water to enter into the pumping chamber once again through the suction valves.

Seidel, A.; Wolf, D.

1984-03-27T23:59:59.000Z

314

Solar Assisted Heat Pump Systems with Ground Heat Exchanger – Simulation Studies  

Science Journals Connector (OSTI)

Abstract Different concepts of solar assisted heat pump systems with ground heat exchanger are simulated according to IEA SHC Task44/HPP Annex38 reference conditions. Two aspects of the concepts are investigated using TRNSYS simulations. First, the solar impact on system efficiency is assessed by the seasonal performance factor. Second, the solar impact on the possible shortening of the ground heat exchanger is evaluated by the minimum temperature at the ground heat exchanger inlet. The simulation results reveal diverging optimums for the concepts. The direct use of solar energy clearly achieves the best effect on the efficiency improvement. A simple domestic hot water system reaches a seasonal performance factor of 4.5 and solar combi-systems seasonal performance factors up to 6. In contrast, the use of solar energy on the cold side of the heat pump achieves the best effects on the shortening of the ground heat exchanger of up to 20%. Two highly sensitive influences are investigated with the developed transient system model. First, the minimum allowed heat source temperature is varied. Here 1 K equals a variation of 0.25 in the seasonal performance or of around 10% ground heat exchanger length. Second, the ground heat exchanger model is simulated without and with a pre-pipe that improves the transient model behavior. The influence of this pre-pipe on the SPF is small for conventionally designed ground heat exchangers, but of around 2 K for the minimum inlet temperature. Therefore, the dynamic model quality reveals potential to reduce the size of the ground heat exchanger corresponding to investment costs.

Erik Bertram

2014-01-01T23:59:59.000Z

315

Test results of a combined distributed ion pump/non-evaporable getter pump design developed as a proposed alternative pumping system for the PEP-II asymmetric B-Factory collider  

SciTech Connect

The authors have built and tested an all-in-one combination plate-type distributed ion pump/non-evaporable getter pump design (DIP/NEG) considered as a proposed alternative pumping system for the PEP-II B-Factory High Energy Ring (HER). The DIP portion of the design used a Penning cell hole size of 12 mm in a mostly uniform magnetic field of 0.18 T. The NEG portion of the design used commercially available non-evaporable getter material type St-707{trademark}. A detailed description of the design is presented along with results of pumping speed measurements.

Holdener, F.; Behne, D.; Hathaway, D. [Lawrence Livermore National Lab., CA (United States)] [and others

1995-04-24T23:59:59.000Z

316

Hydraulic conductivity imaging from 3-D transient hydraulic tomography at several pumping/observation densities  

E-Print Network (OSTI)

of transport and design and operation of ground- water remediation systems, are crucially dependent transient hydraulic tomography at several pumping/observation densities, Water Resour. Res., 49, 7311

Barrash, Warren

317

Carbon and Water Resource Management for Water Distribution Systems  

E-Print Network (OSTI)

the embodied energy in drinking water supply systems: a caselosses to 5% of total drinking water supply for threeResearch Council. Drinking Water Distribution Systems:

Hendrickson, Thomas Peter

2013-01-01T23:59:59.000Z

318

Successful Application of Heat Pumps to a DHC System in the Tokyo Bay Area  

E-Print Network (OSTI)

The Harumi-Island District Heating & Cooling (DHC), which is located in the Tokyo Bay area, introduced the heat pump and thermal storage system with the aim of achieving minimum energy consumption, minimum environmental load, and maximum economical...

Yanagihara, R.; Okagaki, A.

2006-01-01T23:59:59.000Z

319

Simulation Study of Hybrid Ground Source Heat Pump System in the Hot-Humid Climate.  

E-Print Network (OSTI)

??The beachfront hotel with hybrid geothermal heat pump system (HyGSHP), located in the hot-humid climate, is simulated by TRNSYS in the thesis, and the simulation… (more)

Zhu, Jiang

2011-01-01T23:59:59.000Z

320

Measurement of Shaft Vibration Using Ultrasonic Sensor in Sump Pump Systems  

Science Journals Connector (OSTI)

Conventional diagnosis methods for bearings use acceleration sensors. But, the diagnosis method cannot be applied when the bearing is invisible like in sump pump systems in nuclear power plants. For such a cas...

Shogo Tanaka; Hajime Morishige

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

A New Concept of an Electrochemical Heat Pump System: Theoretical Consideration and Experimental Results  

Science Journals Connector (OSTI)

A new concept of an electrochemical heat pump system is described which consists of two identical electrochemical cells operating at different temperatures in opposite directions. The principle is based on the...

L. Dittmar; K. Jüttner; G. Kreysa

1994-01-01T23:59:59.000Z

322

Pumps, pipes and valves: The heart of a system  

SciTech Connect

This is a guide to suppliers of pumps, pipes and valves for construction or repair of hazardous materials. The article contains a compilation of the suppliers/manufacturers and how to contact them, the corrosion resistance of the component, whether double-secondary containment is available, and the material used to construct the component.

NONE

1996-05-01T23:59:59.000Z

323

Role of the System Effect in the Optimization of the Operating Modes of Pumped-Storage Power Plants1  

Science Journals Connector (OSTI)

An original method for optimizing the operation of pumped-storage power plants in the grid under the ... the new power market is presented. The system effect due to the operation of a pumped-storage power plant i...

Yu. A. Miroshnikova

2013-09-01T23:59:59.000Z

324

Energy Savings and Peak Demand Reduction of a SEER 21 Heat Pump vs. a SEER 13 Heat Pump with Attic and Indoor Duct Systems  

SciTech Connect

This report describes results of experiments that were conducted in an unoccupied 1600 square foot house--the Manufactured Housing (MH Lab) at the Florida Solar Energy Center (FSEC)--to evaluate the delivered performance as well as the relative performance of a SEER 21 variable capacity heat pump versus a SEER 13 heat pump. The performance was evaluated with two different duct systems: a standard attic duct system and an indoor duct system located in a dropped-ceiling space.

Cummings, J.; Withers, C.

2014-03-01T23:59:59.000Z

325

Taking Another Look at Pumping Systems: Opportunities Go Well Beyond Just Energy Savings  

E-Print Network (OSTI)

payback periods. Basing decisions, however, on total cost of ownership and established life-cycle cost methodologies provides compelling arguments to shift business decision-making away from initial cost considerations. Pumping systems account... payback periods. Basing decisions, however, on total cost of ownership and established life-cycle cost methodologies provides compelling arguments to shift business decision-making away from initial cost considerations. Pumping systems account...

Tutterow, V.; Walters, T.

2006-01-01T23:59:59.000Z

326

Numerical Study on the Operating Performance of an Indirect Expansion Solar Assisted Multifunctional Heat Pump in Water Heating Mode  

Science Journals Connector (OSTI)

An indirect expansion solar assisted multifunctional heat pump (IE-SAMHP) is ... SAMHP consists of an all-glass evacuated-tube solar collector system, a compressor, two air-...

Ji Jie; Jiang Aiguo; Yang Jichun; Pei Gang…

2009-01-01T23:59:59.000Z

327

Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies  

SciTech Connect

Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from the surface to the downhole motor. The two-phase flow program is directed at understanding the hydrodynamics of two-phase flows. The two-phase flow regime is characterized by a series of flow patterns that are designated as bubble, slug, churn, and annular flow. Churn flow has received very little scientific attention. This lack of attention cannot be justified because calculations predict that the churn flow pattern will exist over a substantial portion of the two-phase flow zone in producing geothermal wells. The University of Houston is experimentally investigating the dynamics of churn flow and is measuring the holdup over the full range of flow space for which churn flow exists. These experiments are being conducted in an air/water vertical two-phase flow loop. Brown University has constructed and is operating a unique two-phase flow research facility specifically designed to address flow problems of relevance to the geothermal industry. An important feature of the facility is that it is dedicated to two-phase flow of a single substance (including evaporation and condensation) as opposed to the case of a two-component two-phase flow. This facility can be operated with horizontal or vertical test sections of constant diameter or with step changes in diameter to simulate a geothermal well profile.

Hanold, R.J.

1983-12-01T23:59:59.000Z

328

Domestic demand-side management (DSM): Role of heat pumps and thermal energy storage (TES) systems  

Science Journals Connector (OSTI)

Heat pumps are seen as a promising technology for load management in the built environment, in combination with the smart grid concept. They can be coupled with thermal energy storage (TES) systems to shift electrical loads from high-peak to off-peak hours, thus serving as a powerful tool in demand-side management (DSM). This paper analyzes heat pumps with radiators or underfloor heating distribution systems coupled with TES with a view to showing how a heat pump system behaves and how it influences the building occupants' thermal comfort under a DSM strategy designed to flatten the shape of the electricity load curve by switching off the heat pump during peak hours (16:00–19:00). The reference scenario for the analysis was Northern Ireland (UK). The results showed that the heat pump is a good tool for the purposes of DSM, also thanks to the use of TES systems, in particular with heating distribution systems that have a low thermal inertia, e.g. radiators. It proved possible to achieve a good control of the indoor temperature, even if the heat pump was turned off for 3 h, and to reduce the electricity bill if a “time of use” tariff structure was adopted.

A. Arteconi; N.J. Hewitt; F. Polonara

2013-01-01T23:59:59.000Z

329

U.S. Department of Energy Pumping System Assessment  

E-Print Network (OSTI)

& environmental stewardship Executive Order 13514 #12;10 Energy management requirements Energy management and water management requirements Energy and Water Audits Metering and benchmarking EPAct 2005 E.O. 13423 E of fiscal year 2015 from a fiscal year 2003 baseline · Water Management Requirements ­ Reduce potable water

Oak Ridge National Laboratory

330

Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line  

DOE Patents (OSTI)

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

Gaul, Christopher J. (Thornton, CO)

2001-01-01T23:59:59.000Z

331

Case Study- The Challenge: Saving Energy at a Sewage Lift Station Through Pump System Modifications  

Energy.gov (U.S. Department of Energy (DOE))

This case study explores how the City of Milford, Connecticut saved energy at the Welches Point sewage lift station. By adding a small booster pump to the sewage pumping system, the city reduced the station's annual energy consumption by 36,096 kWh, or more than 15 percent, which resulted in annual savings of $2,960. With a total implementation cost of $16,000, the project yielded a simple payback of 5.4 years.

332

A Demonstration System for Capturing Geothermal Energy from Mine Waters  

Open Energy Info (EERE)

System for Capturing Geothermal Energy from Mine Waters System for Capturing Geothermal Energy from Mine Waters beneath Butte, MT Geothermal Project Jump to: navigation, search Last modified on July 22, 2011. Project Title A Demonstration System for Capturing Geothermal Energy from Mine Waters beneath Butte, MT Project Type / Topic 1 Recovery Act - Geothermal Technologies Program: Ground Source Heat Pumps Project Type / Topic 2 Topic Area 1: Technology Demonstration Projects Project Description Butte, Montana, like many other mining towns that developed because of either hard-rock minerals or coal, is underlain by now-inactive water-filled mines. In Butte's case, over 10,000 miles of underground workings have been documented, but as in many other mining communities these waters are regarded as more of a liability than asset. Mine waters offer several advantages:

333

Building America Technology Solutions for New and Existing Homes: Multifamily Central Heat Pump Water Heaters (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

To evaluate the performance of central heat pump water heaters for multifamily applications, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California, for 16 months.

334

Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)  

SciTech Connect

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

Not Available

2013-11-01T23:59:59.000Z

335

Asymmetric frequency conversion in nonlinear systems driven by a biharmonic pump  

E-Print Network (OSTI)

A novel mechanism of asymmetric frequency conversion is investigated in nonlinear dispersive devices driven parametrically with a biharmonic pump. When the relative phase between the first and second harmonics combined in a two-tone pump is appropriately tuned, nonreciprocal frequency conversion, either upward or downward, can occur. Full directionality and efficiency of the conversion process is possible, provided that the distribution of pump power over the harmonics is set correctly. While this asymmetric conversion effect is generic, we describe its practical realization in a model system consisting of a current-biased, resistively-shunted Josephson junction. Here, the multiharmonic Josephson oscillations, generated internally from the static current bias, provide the pump drive.

Kamal, Archana; Clarke, John; Devoret, Michel H

2014-01-01T23:59:59.000Z

336

Water preheater system  

SciTech Connect

A heat transfer liquid collects heat in a solar collector and transfers the heat to water in a preheater heat exchanger. Use of a negative-pressure collector by means of an ejector and pressure relief valve allows inexpensive and readily available materials to be used in the collector. Preferably, the preheat heat exchanger is a converted gas hot water heater in which the heat transfer liquid is sprayed onto a portion of the storage tank and is collected in a reservoir. The negative-pressure solar collector can also be used to heat swimming pool water.

Dunstan, Ph.E.

1985-03-12T23:59:59.000Z

337

Optimal design of ground source heat pump system integrated with phase change cooling storage tank in an office building  

E-Print Network (OSTI)

Optimal design of ground source heat pump system integrated with phase change cooling storage tank in an office building Na Zhu*, Yu Lei, Pingfang Hu, Linghong Xu, Zhangning Jiang Department of Building Environment and Equipment Engineering... heat pump system integrated with phase change cooling storage technology could save energy and shift peak load. This paper studied the optimal design of a ground source heat pump system integrated with phase change thermal storage tank in an office...

Zhu, N.

2014-01-01T23:59:59.000Z

338

Large Solar Assisted Heat Pump Systems in Collective Housing: In-situ Monitoring Results for Summer Season  

Science Journals Connector (OSTI)

Abstract This article presents the behavior of an existing system combining solar collectors and heat pumps at large scale (10’000 living m2, more than 1’000 m2 solar collectors) for space heating and domestic hot water production, focusing on summer period. Ongoing detailed monitoring enables to measure its energy performance. The monitoring results for 2012 show a system SPF of 2.9 (2.6 in winter and 4.4 in summer). The direct solar fraction in summer is lower than 50%, which is low considering the oversizing of the solar collector area for domestic hot water production. The high domestic hot water demand (?50 kWh/m2/yr whereas the usual value is around 20) can partly explain this low value, but other factors should also be considered. The results presented in this article are part of a research project aiming to assess the relevance of the concept of coupling solar thermal and heat pumps in various types of building (especially existing buildings with low efficient thermal envelope).

Carolina Fraga; Floriane Mermoud; Pierre Hollmuller; Eric Pampaloni; Bernard Lachal

2014-01-01T23:59:59.000Z

339

Heat pumps and under floor heating as a heating system for Finnish low-rise residential buildings.  

E-Print Network (OSTI)

??In bachelor’s thesis the study of under floor heating system with ground source heat pump for the heat transfers fluid heating is considered. The case… (more)

Chuduk, Svetlana

2010-01-01T23:59:59.000Z

340

Study of Energy and Demand Savings on a High Efficiency Hydraulic Pump System with Infinite Turn Down Technology (ITDT)  

E-Print Network (OSTI)

and demand savings between an injection molding machine retrofitted with the high efficiency hydraulic pump system or variable frequency drive will also be presented....

Sfeir, R. A.; Kanungo, A.; Liou, S.

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

NREL: Learning - Geothermal Heat Pump Basics  

NLE Websites -- All DOE Office Websites (Extended Search)

Heat Pump Basics Heat Pump Basics Photo of the West Philadelphia Enterprise Center. The West Philadelphia Enterprise Center uses a geothermal heat pump system for more than 31,000 square feet of space. Geothermal heat pumps take advantage of the nearly constant temperature of the Earth to heat and cool buildings. The shallow ground, or the upper 10 feet of the Earth, maintains a temperature between 50° and 60°F (10°-16°C). This temperature is warmer than the air above it in the winter and cooler in the summer. Geothermal heat pump systems consist of three parts: the ground heat exchanger, the heat pump unit, and the air delivery system (ductwork). The heat exchanger is a system of pipes called a loop, which is buried in the shallow ground near the building. A fluid (usually water or a mixture of

342

Reducing Pumping Related Electricity Costs - A Case Study of Three Water Utility Companies in Zambia.  

E-Print Network (OSTI)

?? Electric pumps are extensively used in many industrial and commercial applications worldwide and account for about twenty percent of the world’s electrical energy demand.… (more)

Siyingwa, Bennet

2013-01-01T23:59:59.000Z

343

Characteristics of a semicircular heat exchanger used in a water heated condenser pump .  

E-Print Network (OSTI)

??According to literature 6% of South Africa’s primary energy consumption could be saved if heat pumps were used to their full technical potential. Although there… (more)

Da Veiga, Willem Richter

2009-01-01T23:59:59.000Z

344

Maximizing Gross Margin of a Pumped Storage Hydroelectric Facility Under Uncertainty in Price and Water Inflow.  

E-Print Network (OSTI)

??The operation of a pumped storage hydroelectric facility is subject to uncertainty. This is especially true in today’s energy markets. Published models to achieve optimal… (more)

Ikudo, Akina

2009-01-01T23:59:59.000Z

345

Design and performance of main vacuum pumping system of SST-1 Tokamak  

Science Journals Connector (OSTI)

Abstract Steady-state Superconducting Tokamak (SST-1) was installed and it is commissioning for overall vacuum integrity, magnet systems functionality in terms of successful cool down to 4.5 K and charging up to 10 kA current was started from August 2012. Plasma operation of 100 kA current for more than 100 ms was also envisaged. It is comprised of vacuum vessel (VV) and cryostat (CST). Vacuum vessel, an ultra-high (UHV) vacuum chamber with net volume of 23 m3 was maintained at the base pressure of 6.3 × 10?7 mbar for plasma confinement. Cryostat, a high-vacuum (HV) chamber with empty volume 39 m3 housing superconducting magnet system, bubble thermal shields and hydraulics for these circuits, maintained at 1.3 × 10?5 mbar in order to provide suitable environment for these components. In order to achieve these ultimate vacuums, two numbers of turbo-molecular pumps (TMP) are installed in vacuum vessel while three numbers of turbo-molecular pumps are installed in cryostat. Initial pumping of both the chambers was carried out by using suitable Roots pumps. PXI based real time controlled system is used for remote operation of the complete pumping operation. In order to achieve UHV inside the vacuum vessel, it was baked at 150 °C for longer duration. Aluminum wire-seals were used for all non-circular demountable ports and a leak tightness < 1.0 × 10?9 mbar l/s were achieved.

Ziauddin Khan; Firozkhan Pathan; Siju George; Kalpesh Dhanani; Yuvakiran Paravastu; Pratibha Semwal; Subrata Pradhan

2014-01-01T23:59:59.000Z

346

Quantized Pumping and Topology of the Phase Diagram for a System of Interacting Bosons  

SciTech Connect

Interacting lattice bosons at integer filling can support two distinct insulating phases, which are separated by a critical point: the Mott insulator and the Haldane insulator [E. G. Dalla Torre, E. Berg, and E. Altman, Phys. Rev. Lett. 97, 260401 (2006).]. The critical point can be gapped out by breaking lattice inversion symmetry. Here, we show that encircling this critical point adiabatically pumps one boson across the system. When multiple chains are coupled, the two insulating phases are no longer sharply distinct, but the pumping property survives. This leads to strict constraints on the topology of the phase diagram of systems of quasi-one-dimensional interacting bosons.

Berg, Erez [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Levin, Michael [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States)] [Department of Physics, University of Maryland, College Park, Maryland 20742-4111 (United States); Altman, Ehud [Department of Condensed Matter Physics, The Weizmann Institute of Science, Rehovot, 76100 (Israel)

2011-03-18T23:59:59.000Z

347

Continuous Commissioning of a Central Chilled Water & Hot Water System  

E-Print Network (OSTI)

A central chilled water / hot water system provides cooling / heating energy from central utility plants to multiple customers (buildings) through campus distribution loops. To effectively transport the chilled water and hot water to the buildings...

Deng, S.; Turner, W. D.; Batten, T.; Liu, M.

2000-01-01T23:59:59.000Z

348

Permanent scatterer InSAR reveals seasonal and long-term aquifer-system response to groundwater pumping and artificial  

E-Print Network (OSTI)

and precisely measuring long-term and seasonal aquifer-system response to pumping and recharge. In contrast this methodology can be utilized in heavily pumped groundwater basins to analyze aquifer-system response to long characterize the storage properties of an aquifer system with a high degree of spatial resolution. Citation

Amelung, Falk

349

Systems study of drilling for installation of geothermal heat pumps  

SciTech Connect

Geothermal, or ground-source, heat pumps (GHP) are much more efficient than air-source units such as conventional air conditioners. A major obstacle to their use is the relatively high initial cost of installing the heat-exchange loops into the ground. In an effort to identify drivers which influence installation cost, a number of site visits were made during 1996 to assess the state-of-the-art in drilling for GHP loop installation. As an aid to quantifying the effect of various drilling-process improvements, we constructed a spread-sheet based on estimated time and material costs for all the activities required in a typical loop-field installation. By substituting different (improved) values into specific activity costs, the effect on total project costs can be easily seen. This report contains brief descriptions of the site visits, key points learned during the visits, copies of the spread-sheet, recommendations for further work, and sample results from sensitivity analysis using the spread-sheet.

Finger, J.T.; Sullivan, W.N.; Jacobson, R.D.; Pierce, K.G.

1997-09-01T23:59:59.000Z

350

Split-System Cold Climate Heat Pump | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

prototype test system ORNLEmerson laboratory prototype test system Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN Partners: -- Unico, Inc. - St. Louis, MO --...

351

A Review of the Security of Insulin Pump Infusion Systems Nathanael Paul, Ph.D. Tadayoshi Kohno, Ph.D. David C. Klonoff, M.D., FACP  

E-Print Network (OSTI)

A Review of the Security of Insulin Pump Infusion Systems Nathanael Paul, Ph.D. Tadayoshi Kohno, Ph is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we safety and information security. From 2005 to 2009, there were 56,000 adverse events in infusion pump

Matsuoka, Yoky

352

The research of 1D / 3D coupling simulation on pump and pipe system  

Science Journals Connector (OSTI)

The research of performances of hydraulic mechanical depends on static complete characteristic curves, which have great difference compared with the actual work condition and have accidents potential. So we need a new way to compute the dynamic system, which is more reasonable. So the method to couple one dimensional simulation and three dimensional CFD analysis based on Flowmaster and Fluent is explored, and the dynamic characteristics and internal flow of the pumping system are analyzed. First, a pipe system model is created in Flowmaster and a pump model is created in Fluent; then VB code and scheme code are used to realize the automated operation for Flowmaster and Fluent; at last, the exchange of data between these two parts is realized by an interface program. In this paper, the interaction between pumps and pipe system are analyzed by coupling one-dimensional and three-dimensional simulations. This study would be helpful to identify the influences of the rapid adjustment process on stability of system and provide guides for design of pump system.

D Z Wu; Q L Liu; P Wu; L Q Wang; T Paulus; B G Wang; M Oesterle

2012-01-01T23:59:59.000Z

353

Experimental Research on Solar Assisted Heat Pump Heating System with Latent Heat Storage  

E-Print Network (OSTI)

-reaching meaning of solving energy and environment problems if new type energy conservation and environment protection heating system ? solar assisted ground-source heat pump (SAGHP) heating system with a latent heat storage tank will be practical... was established at the laboratory of construction energy conservation in Harbin Institute of Technology (HIT) in 2004. It added a latent heat storage tank in original SAGHP system. The schematic diagram of the system is shown in Figure 1. The experimental...

Han, Z.; Zheng, M.; Liu, W.; Wang, F.

2006-01-01T23:59:59.000Z

354

Geothermal Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Geothermal Heat Pumps Geothermal Heat Pumps June 24, 2012 - 5:08pm Addthis Watch how geothermal heat pumps heat and cool buildings by concentrating the naturally existing heat contained within the earth -- a clean, reliable, and renewable source of energy. How does it work? A geothermal heat pump uses the constant below ground temperature of soil or water to heat and cool your home. Geothermal heat pumps (GHPs), sometimes referred to as GeoExchange, earth-coupled, ground-source, or water-source heat pumps, have been in use since the late 1940s. They use the constant temperature of the earth as the exchange medium instead of the outside air temperature. This allows the system to reach fairly high efficiencies (300% to 600%) on the coldest

355

Improving water and energy metabolism efficiency in urban water supply system through pressure stabilization by optimal operation on water tanks  

Science Journals Connector (OSTI)

Abstract Water supply consumes 2–3% of the worldwide energy. Water distribution system, which accounts for 70% electricity consumption of water supply, is a key link of urban water and energy metabolism. The operation of the secondary water supply system (SWSS) has great influence on the pressure stability and associated energy consumption as well as water loss of urban water distribution. This research developed an approach based on the hydraulic solver EPANET and genetic algorithm (GA) to investigate the impacts of two different operation strategies, user demand regulation (UDR) and tank level regulation (TLR) of SWSS, on pressure stability and energy efficiency. The results showed that the strategy of TLR could reduce the pressure fluctuations and increase the minimal pressure of the distribution network under the same supply–demand condition. Reduction of the pressure fluctuations is beneficial to the reliability and leakage control of pipe networks. Increase of the minimal pressure indicates that less energy is lost during the distribution. Therefore, the TLR strategy of SWSS can support to initiatively lower the water pressure of the pumps at the water plant outlet, thus improves the water and energy metabolism efficiency in urban water supply system.

Qiang Xu; Qiuwen Chen; Siliang Qi; Desuo Cai

2014-01-01T23:59:59.000Z

356

Parametric sensitivity study for solar-assisted heat-pump systems. Final report  

SciTech Connect

A sensitivity study is performed of the engineering and economic parameters affecting life-cycle costs for solar-assisted heat pump systems. The change in energy usage resulting from each engineering parameter varied has been developed from computer simulations, and is compared with results from a stand-alone heat pump system. Three geographical locations are considered: Washington, DC, Fort Worth, TX, and Madison, WI. Results indicate that most engineering changes to the systems studied do not provide significant energy savings. The most promising parameters to vary are the solar collector parameters tau ..cap alpha.. and U/sub L/ the heat pump capactiy at design point, and the minimum utilizable evaporator temperature. Costs associated with each change are estimated, and life-cycle costs computed for both engineering parameters and economic variations in interest rate, discount rate, tax credits, fuel unit costs and fuel inflation rates. Results indicate that none of the feasible engineering changes for the system configuration studied will make these systems economically competitive with the stand-alone heat pump without a considerable tax credit.

White, N.M.; Morehouse, J.H.

1981-07-01T23:59:59.000Z

357

Electronic Submersible Pump (ESP) Technology and Limitations with Respect to Geothermal Systems (Fact Sheet)  

SciTech Connect

The current state of geothermal technology has limitations that hinder the expansion of utility scale power. One limitation that has been discussed by the current industry is the limitation of Electric Submersible Pump (ESP) technology. With the exception of a few geothermal fields artificial lift technology is dominated by line shaft pump (LSP) technology. LSP's utilize a pump near or below reservoir depth, which is attached to a power shaft that is attached to a motor above ground. The primary difference between an LSP and an ESP is that an ESP motor is attached directly to the pump which eliminates the power shaft. This configuration requires that the motor is submersed in the geothermal resource. ESP technology is widely used in oil production. However, the operating conditions in an oil field vary significantly from a geothermal system. One of the most notable differences when discussing artificial lift is that geothermal systems operate at significantly higher flow rates and with the potential addition of Enhanced Geothermal Systems (EGS) even greater depths. The depths and flow rates associated with geothermal systems require extreme horsepower ratings. Geothermal systems also operate in a variety of conditions including but not limited to; high temperature, high salinity, high concentrations of total dissolved solids (TDS), and non-condensable gases.

Not Available

2014-09-01T23:59:59.000Z

358

Preoperational test report, cross-site transfer water flush system (POTP-001)  

SciTech Connect

This report documents the results of the testing performed per POTP-001, for the Cross-Site Transfer Water Flush System. (HNF-1552, Rev. 0) The Flush System consists of a 47,000 gallon tank (302C), a 20 hp pump, two 498kW heaters, a caustic addition pump, various valves, instruments, and piping. The purpose of this system is to provide flush water at 140 F, 140gpm, and pH 11-12 for the Cross-Site Transfer System operation.

Parsons, G.L.

1998-02-20T23:59:59.000Z

359

Design and Construction of a High Pressure System for Evaluating Multiphase Twin-Screw Pumps  

E-Print Network (OSTI)

Twin-screw pumps are currently sold by manufacturers without adequate data predicting the pump behavior when pumping multiphase mixtures. In light of the fact that pump behavior is known to change significantly under these conditions, a new closed...

Hatch, Theodore Isaac

2013-08-26T23:59:59.000Z

360

DSM strategy for national water pumping systems / André Nortjé.  

E-Print Network (OSTI)

??The continual increase in electrical energy demand in South Africa has resulted in a precariously low reserve margin in supply from the primary utility, Eskom.… (more)

Nortjé, André

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Study on Alternative Refrigerants for Direct Expansion Solar Assisted Heat Pump System  

Science Journals Connector (OSTI)

This paper reports the investigation results of the possibilities for using pure and mixed refrigerants as working fluids to replace R22 for the DX-SAHP systems. Firstly, pure refrigerants are compared in terms of COP, discharge temperature and mass ... Keywords: direct expansion, heat pump, refrigerant, steady state, simulation

Hong Li

2012-05-01T23:59:59.000Z

362

A Novel Integrated Frozen Soil Thermal Energy Storage and Ground-Source Heat Pump System  

E-Print Network (OSTI)

In this paper, a novel integrated frozen soil thermal energy storage and ground-source heat pump (IFSTS&GSHP) system in which the GHE can act as both cold thermal energy storage device and heat exchanger for GSHP is first presented. The IFSTS...

Jiang, Y.; Yao, Y.; Rong, L.; Ma, Z.

2006-01-01T23:59:59.000Z

363

Nonsensor control of centrifugal water pump with asynchronous electric-drive motor based on extended Kalman filter  

Science Journals Connector (OSTI)

An approach is described for estimating the pump’s variables based only on measuring the motor’s electrical variables. The method is based on extended Kalman filter estimation of the pump’s shaft power and vel...

O. I. Kiselichnik; M. Bodson

2011-02-01T23:59:59.000Z

364

STUDY OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS  

E-Print Network (OSTI)

STUDY OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS OF FROST GROWTH ON HEAT EXCHANGERS USED AS OUTDOOR COILS IN AIR SOURCE HEAT PUMP SYSTEMS Dissertation . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3.5.3 Air Side Heat Transfer Rates . . . . . . . . . . . . . . . . . . 43 3.5.4 Fluid Side Heat

365

Water/Wastewater Engineering Report (High Efficiency Pump/Motor Replacement - M2 Model)  

E-Print Network (OSTI)

. In eGRID the NOx production for each power plant is provided for ten electric utility suppliers (i.e., AEP, Austin Energy, Brownsville Public Utility, LCRA, Reliant, San Antonio Public Service, South Texas Coop, TMPP, TNMP, and TXU). In the case... about the old pump and motor including motor HP, motor nominal efficiency, rated pump capacity, and total dynamic head. Then the user can choose from one of the three screens (screen 2A, 2B or 2C) to input the flow rate, motor power/head, old pump...

Liu, Z.; Brumbelow, K.; Haberl, J. S.

2006-10-30T23:59:59.000Z

366

Optimal Ground-Source Heat Pump System Design  

Energy.gov (U.S. Department of Energy (DOE))

Project objectives: Develop a least-cost design tool (OptGSHP) that will enable GSHP developers to analyze system cost and performance in a variety of building applications to support both design, operational and purchase decisions. Integrate groundwater flow and heat transport into OptGSHP. Demonstrate the usefulness of OptGSHP and the significance of a systems approach to the design of GSHP systems.

367

Multiple pump housing  

DOE Patents (OSTI)

A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

Donoho, II, Michael R. (Edelstein, IL); Elliott, Christopher M. (Metamora, IL)

2010-03-23T23:59:59.000Z

368

Water in clay-water systems (1) Philip F. LOW  

E-Print Network (OSTI)

Water in clay-water systems (1) Philip F. LOW Department of Agronomy, Purdue University. Agric. Exp. Stn., West Lafayette, IN 47907, U.S.A. SUMMARY The swelling of clay-water systems and the thermodynamic, hydrodynamic and spectroscopic properties of water in these systems are discussed. The swelling

Paris-Sud XI, Université de

369

Demonstration of SCADA system to Manage Oilfield Pump Off Controllers  

SciTech Connect

PC-based SCADA systems are today widely accepted by the oil and gas industry, thanks to the increased power and capabilities of PCs, their reduced costs, and the wider use of PCs by energy companies in office and field operations. More and more field operators are using laptops in their daily work duties. This has made the PC the choice for field SCADA systems, and for making SCADA data available throughout company operations. As PCs have become more powerful, it has allowed SCADA software developers to add more capabilities to their systems. SCADA systems have become tools that now help field operators perform their jobs more efficiently, facilitate in optimizing producing wells, provide an active interface for monitoring and controlling plants and compressors, and provide real-time and historical well data to engineers to help them develop strategies for optimizing field operations.

Newquist, Dan

2000-09-11T23:59:59.000Z

370

Supply Air Temperature Control Using a VFD Pump  

E-Print Network (OSTI)

Supply Air Temperature Control Using a VFD Pump Bin Zheng and Mingsheng Liu Ph.D., P.E. Energy Systems Laboratory University of Nebraska-Lincoln Abstract Traditionally, chilled water pump speed is modulated to maintain the water loop... speed to maintain the supply air temperature set point can: 1. save pump electricity energy; 2. improve control valve control performance; 3. reduce control valve initial cost; 4. save maintenance cost. References [1] Zheng B., Liu M. (2004...

Zheng, B.; Liu, M.

2005-01-01T23:59:59.000Z

371

Building America Technology Solutions for New and Existing Homes: Field Performance of Heat Pump Water Heaters in the Northeast (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

In this project, the Consortium for Advanced Residential Buildings evaluated three newly released heat pump water heater products in order to provide publicly available field data on these products.

372

Stochastic pump effect and geometric phases in dissipative and stochastic systems  

SciTech Connect

The success of Berry phases in quantum mechanics stimulated the study of similar phenomena in other areas of physics, including the theory of living cell locomotion and motion of patterns in nonlinear media. More recently, geometric phases have been applied to systems operating in a strongly stochastic environment, such as molecular motors. We discuss such geometric effects in purely classical dissipative stochastic systems and their role in the theory of the stochastic pump effect (SPE).

Sinitsyn, Nikolai [Los Alamos National Laboratory

2008-01-01T23:59:59.000Z

373

Geothermal Heat Pumps Produce Dramatic Savings  

E-Print Network (OSTI)

applications. One approach now expanding the direct use of geothermal energy is coupling this energy resource with high temperature, industrial-type water-to water heat pumps. Such systems can tap geothermal energy in 50 F to 120 F water, normally available...

Niess, R. C.

1983-01-01T23:59:59.000Z

374

Open-Cycle Vapor Compression Heat Pump System  

E-Print Network (OSTI)

to the desired pressure level for process use. The compressor is driven by a gas turbine or gas engine prime mover. To enhance the system performance, the prime mover exhaust and/or cooling jacket heat is recovered to generate additional process steam or hot...

Pasquinelli, D. M.; Becker, F. E.

1983-01-01T23:59:59.000Z

375

Research on Optimal Operation Method of Large Scale Urban Water Distribution System  

Science Journals Connector (OSTI)

Abstract In consideration of using fewer decision variables in building least cost pumping operation optimal, the two-phase optimal method is used as the frame. By abstracting pump stations into high level reservoirs, the water distribution system hydraulic model can be modified into a modality, which can be used in first optimal phase of two-phase optimal method. And by building on feasible pump combination database, a new optimal method in the second optimal phase will be proposed. And the proposed new method in the second optimal phase will be embedded into the first optimal phase, so that the problem of results discordant in different phases of two-phase optimal method will be solved. By introducing new concept and improving present optimal method, a more practical optimal operation method of water distribution system (WDS) will be established. By applying to a large scale water distribution system, the practicability of proposed method has been evaluated.

X. Jin; W. Wu

2014-01-01T23:59:59.000Z

376

Performance analysis of PV pumping systems using switched reluctance motor drives  

SciTech Connect

A PV pumping system using switched reluctance motor (SRM) is thoroughly investigated in this work. This motor is supplied by a d.c. voltage through a simple switching circuit. This drive circuit is much simpler than the normal d.c./a.c. inverter required to supply the induction motor. The efficiency of this motor is considerably higher than that of the equivalent d.c. or induction motors. In addition, because of the simple construction, SRM is cheaper than these conventional drives. Because of the above advantages of the SRM, the proposed system has higher efficiency and lower cost as compared with other systems. A design example is studied in detail to explore the advantages of PV pumping systems based on this new drive. The study of the performance of the proposed system showed that the operating efficiency of the motor is about 85% during most of its working time. The matching efficiency between the PV array and the proposed system approaches 95%. The major part of the losses takes place in the pump and the riser pipes. This loss represents one-third of the total available energy. 21 refs., 10 figs.

Metwally, H.M.B. [Zagazig Univ. (Egypt)] [Zagazig Univ. (Egypt); Anis, W.R. [Ain Shams Univ., Cairo (Egypt)] [Ain Shams Univ., Cairo (Egypt)

1996-12-31T23:59:59.000Z

377

Comparison between automated and manual DSM pumping projects / R.P. Richter.  

E-Print Network (OSTI)

??The purpose of this dissertation is to identify the best alternative method of load shifting on clear water pumping systems in the mining industry. This… (more)

Richter, Rudolph Petrus

2008-01-01T23:59:59.000Z

378

Review of combined photovoltaic/thermal collector: solar assisted heat pump system options  

SciTech Connect

The advantages of using photovoltaic (PV) and combined photovoltaic/thermal (PV/T) collectors in conjunction with residential heat pumps are examined. The thermal and electrical power requirements of similar residences in New York City and Fort Worth are the loads under consideration. The TRNSYS energy balance program is used to simulate the operations of parallel, series, and cascade solar assisted heat pump systems. Similar work involving exclusively thermal collectors is reviewed, and the distinctions between thermal and PV/T systems are emphasized. Provided the defrost problem can be satisfactorily controlled, lifecycle cost analyses show that at both locations the optimum collector area is less than 50 m/sup 2/ and that the parallel system is preferred.

Sheldon, D.B.; Russell, M.C.

1980-01-01T23:59:59.000Z

379

Adjustable Speed Pumping Applications  

Energy.gov (U.S. Department of Energy (DOE))

This tip sheet provides practical tips on the application of adjustable speed drives in industrial pumping systems.

380

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

Building Energy Efficiency Standards .. 4 Multi-Family Water Heating.. 4 Pipe HeatBuilding Energy Efficiency Standards The scope of this task included the following subtasks; Multi-Family Water Heating, Pipe Heat

Lutz, Jim

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Experimental analysis of a direct expansion solar assisted heat pump with integral storage tank for domestic water heating under zero solar radiation conditions  

Science Journals Connector (OSTI)

This paper deals with the experimental evaluation of the performance of a direct expansion solar assisted heat pump water heating (DX-SAHPWH) system working under zero solar radiation conditions at static heating operation mode of the storage tank. The DX-SAHPWH system includes two bare solar collectors as evaporator, a \\{R134a\\} rotary-type hermetic compressor, a thermostatic expansion valve and a helical coil condenser immersed in a 300 L water storage tank. The zero solar radiation and stable ambient air temperature working conditions were established by placing the solar collectors into a climate chamber. The analysis is based on experimental data taken from the DX-SAHPWH provided by the manufacturer and equipped with an appropriate data acquisition system. In the paper, the experimental facility, the data acquisition system and the experimental methodology are described. Performance parameters to evaluate the energy efficiency, such as COP and equivalent seasonal performance factors (SPFe) for the heating period, and the water thermal stratification in the storage tank are defined and obtained from the experimental data. Results from the experimental analysis under transient operating working conditions of the DX-SAHPWH system and its main components are shown and discussed. Lastly, the Huang and Lee DX-SAHPWH performance evaluation method was applied resulting in a characteristic COP of 3.23 for the DX-SAHPWH system evaluated under zero solar radiation condition.

José Fernández-Seara; Carolina Piñeiro; J. Alberto Dopazo; F. Fernandes; Paulo X.B. Sousa

2012-01-01T23:59:59.000Z

382

Robust Energy Cost Optimization of Water Distribution System with ...  

E-Print Network (OSTI)

Energy cost optimization of a water-supply network is a very important ..... ci(t) is the cost of pumping in a unit of water from source # i in period t (in ... of the pump, ? is an appropriate constant factor, and ?(t) is the price of energy (H is measured.

2011-02-21T23:59:59.000Z

383

AN OPTIMIZED TWO-CAPACITY ADVANCED ELECTRIC HEAT PUMP S. E. Veyo, Manager, Heat Exchange Systems Research  

E-Print Network (OSTI)

#12;AN OPTIMIZED TWO-CAPACITY ADVANCED ELECTRIC HEAT PUMP S. E. Veyo S. E. Veyo, Manager, Heat Exchange Systems Research Westinghouse Electric Corporation, R&D Center 1310 Beulah Road Pittsburgh, PA 15235 KEYWORDS: heat pump, air conditioner, electric, residential, energy, compressor, fan, blower, heat

Oak Ridge National Laboratory

384

Alternative backing up pump for turbomolecular pumps  

DOE Patents (OSTI)

As an alternative to the use of a mechanical backing pump in the application of wide range turbomolecular pumps in ultra-high and extra high vacuum applications, palladium oxide is used to convert hydrogen present in the evacuation stream and related volumes to water with the water then being cryo-pumped to a low pressure of below about 1.e.sup.-3 Torr at 150.degree. K. Cryo-pumping is achieved using a low cost Kleemenco cycle cryocooler, a somewhat more expensive thermoelectric cooler, a Venturi cooler or a similar device to achieve the required minimization of hydrogen partial pressure.

Myneni, Ganapati Rao (Yorktown, VA)

2003-04-22T23:59:59.000Z

385

Solar hot water system installed at Las Vegas, Nevada. Final report  

SciTech Connect

The solar hot water system installed at LaQuinta Motor Inn Inc., at Las Vegas, Nevada is described. The Inn is a three-story building with a flat roof for installation of the solar panels. The system consists of 1200 square feet of liquid flat plate collectors, a 2500 gallon insulated vertical steel storage tank, two heat exchangers and pumps and controls. The system was designed to supply approximately 74 percent of the total hot water load.

None

1981-01-01T23:59:59.000Z

386

Energy 101: Geothermal Heat Pumps  

SciTech Connect

An energy-efficient heating and cooling alternative, the geothermal heat pump system moves heat from the ground to a building (or from a building to the ground) through a series of flexible pipe "loops" containing water. This edition of Energy 101 explores the benefits Geothermal and the science behind how it all comes together.

None

2011-01-01T23:59:59.000Z

387

Energy 101: Geothermal Heat Pumps  

ScienceCinema (OSTI)

An energy-efficient heating and cooling alternative, the geothermal heat pump system moves heat from the ground to a building (or from a building to the ground) through a series of flexible pipe "loops" containing water. This edition of Energy 101 explores the benefits Geothermal and the science behind how it all comes together.

None

2013-05-29T23:59:59.000Z

388

Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future Vol.VIII-13-3 Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC Wei Mu Suilin Wang Shuyuan Pan Yongzheng Shi Master Student... the Jurisdiction of Beijing Municipality (BJE10016200511). REFERENCES [1]Rongguang Wang,Yufeng Zhang,Yang,Xiaotong Zheng. Study on Direct Use Of Geothermal Energy For Heating And Its Energy Efficency Effects [J]. ACTA ENERGIAE SOLARIS SINICA, 2002, 23...

Mu, W.; Wang, S.; Pan, S.; Shi, Y.

2006-01-01T23:59:59.000Z

389

Select an Energy-Efficient Centrifugal Pump  

SciTech Connect

BestPractices Program tip sheet discussing pumping system efficiency by selecting an energy-efficient centrifugal pump.

Not Available

2005-10-01T23:59:59.000Z

390

Water Research 38 (2004) 38693880 A reactor model for pulsed pumping groundwater remediation  

E-Print Network (OSTI)

to cost effectively remediate a carbon tetrachloride plume in Schoolcraft, Michigan. The pulsed pumping of Schoolcraft Plume A, a carbon tetrachloride plume in an unconfined aquifer in south- west Michigan (Hyndman et;carbon tetrachloride into carbon dioxide and other non- volatile organic compounds without production

Lastoskie, Christian M.

391

Chapter 13 - Progressing cavity pumps  

Science Journals Connector (OSTI)

Publisher Summary Progressing cavity pumps (PCPs) have the advantage of being able to easily pump solids, liquids, and gasses. With comparatively the lowest capital cost and highest operating efficiencies of any ALS, \\{PCPs\\} are the preferred artificial lift system for many CBM operations. Dewatering CBM wells with \\{PCPs\\} is a relatively routine operation that has been deployed successfully since the mid-1980s. The PC pump is composed of two components, the rotor and the stator. The rotor is manufactured from high strength steel and covered with a chrome layer 0.010 to 0.020 inches thick. The rotor is the only moving component of the pump. The stator has an internal helix shape molded into an elastomer compound that is chemically bonded to the inside of a steel tube. When the rotor is inserted into the stator, it creates a continuous seal line (compression/interference fit between the rotor and stator elastomer) that extends from the pump suction to discharge. This creates a series of identical, but separate, cavities that progress from the pump suction to the discharge as the rotor turns. Water production handling, gas production handling, critical tubing flow velocity, and pump landing depth are briefly discussed in this chapter

James F. Lea; Henry V. Nickens; Mike R. Wells

2008-01-01T23:59:59.000Z

392

Boiler Upgrades and Decentralizing Steam Systems Save Water and Energy at Naval Air Station Oceana  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Location at NAS Oceana. Location at NAS Oceana. by these changes, including bachelor housing, hangers, the galley, office buildings, the chapel, and maintenance facilities. This ESPC also included installing ground source heat pumps in three buildings, adding digital control systems to increase heating, ventilation and air conditioning (HVAC) efficiency, efficient lighting retrofits, and other water conservation measures. These other water conservation measures include over 5,000 water efficient domestic fixtures, includ- ing faucets, showerheads, and toilets

393

Boiler Upgrades and Decentralizing Steam Systems Save Water and Energy at Naval Air Station Oceana  

NLE Websites -- All DOE Office Websites (Extended Search)

Location at NAS Oceana. Location at NAS Oceana. by these changes, including bachelor housing, hangers, the galley, office buildings, the chapel, and maintenance facilities. This ESPC also included installing ground source heat pumps in three buildings, adding digital control systems to increase heating, ventilation and air conditioning (HVAC) efficiency, efficient lighting retrofits, and other water conservation measures. These other water conservation measures include over 5,000 water efficient domestic fixtures, includ- ing faucets, showerheads, and toilets

394

System Modeling and Building Energy Simulations of Gas Engine Driven Heat Pump  

SciTech Connect

To improve the system performance of a gas engine driven heat pump (GHP) system, an analytical modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated with a detailed vapor compression heat pump system design model. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using the desiccant system the sensible heat ratio (SHR- sensible heat ratio) can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% at rated operating conditions. In addtion,using EnergyPlus, building energy simulations have been conducted to assess annual energy consumptions of GHP in sixteen US cities, and the performances are compared to a baseline unit, which has a electrically-driven air conditioner with the seasonal COP of 4.1 for space cooling and a gas funace with 90% fuel efficiency for space heating.

Mahderekal, Isaac [Oak Ridge National Laboratory (ORNL); Vineyard, Edward [Oak Ridge National Laboratory (ORNL)

2013-01-01T23:59:59.000Z

395

Intermittent experimental study of a vertical ground source heat pump system  

Science Journals Connector (OSTI)

Abstract In this paper, the intermittent experiment of a vertical ground source heat pump (GSHP) system is investigated and the corresponding geo-temperature variations are studied. The performance of the GSHP system under intermittent operation and the comparisons of different intermittent modes are presented in the paper. The parameters of soil backfill material, air temperature and inlet volume flow rate are also investigated. Experimental results suggest that, due to the recovery in ground thermal energy in intermittent time, the heat exchange rate and the operation performance coefficient (COP) of the heat pump increases, and the compressor power decreases in the successive working. But an insufficient soil recovery time leads to a rapid decline of the performance parameters and the soil temperature. The temperature transports faster under large soil thermal conductivity conditions and the soil temperature decreases more quickly and recovers more slowly with larger inlet flow rate and lower weather temperature for different soil thermal diffusivities. Through multiple nonlinear regression analysis, a curve formula can be fitted to predict the soil temperature variations under intermittent operation of the ground source heat pump in winter, Dalian. It can be found that the soil temperature increases at an exponential function with each factor.

Yan Shang; Ming Dong; Sufen Li

2014-01-01T23:59:59.000Z

396

LANSCE Drift Tube Linac Water Control System Refurbishment  

SciTech Connect

There are several refurbishment projects underway at the Los Alamos National Laboratory LANSCE linear accelerator. Systems involved are: RF, water cooling, networks, diagnostics, timing, controls, etc. The Drift Tube Linac (DTL) portion of the accelerator consists of four DTL tanks, each with three independent water control systems. The systems are about 40 years old, use outdated and non-replaceable equipment and NIM bin control modules, are beyond their design life and provide unstable temperature control. Insufficient instrumentation and documentation further complicate efforts at maintaining system performance. Detailed design of the replacement cooling systems is currently in progress. Previous design experience on the SNS accelerator water cooling systems will be leveraged, see the SNS DTL FDR. Plans call for replacement of water piping, manifolds, pumps, valves, mix tanks, instrumentation (flow, pressure and temperature) and control system hardware and software. This presentation will focus on the control system design with specific attention on planned use of the National Instruments Compact RIO platform with the Experimental Physics and Industrial Control system (EPICS) software toolkit.

Marroquin, Pilar S. [Los Alamos National Laboratory

2011-01-01T23:59:59.000Z

397

WATER DISTRIBUTION SYSTEM OPERATION: APPLICATION OF  

E-Print Network (OSTI)

CHAPTER 5 WATER DISTRIBUTION SYSTEM OPERATION: APPLICATION OF SIMULATED ANNEALING Fred E. Goldman Arizona State University, Tempe, Arizona 5.1 INTRODUCTION The operation of water distribution systems affects the water quality in these systems. EPA regulations require that water quality be maintained

Mays, Larry W.

398

Hybrid Membrane System for Industrial Water Reuse  

Energy.gov (U.S. Department of Energy (DOE))

Demonstrate an advanced water treatment and reuse process in a single hybrid system that combines forward osmosis with membrane distillation to achieve greater efficiency and increased water reuse.

399

Numerical Simulation of a Latent Heat Storage System of a Solar-Aided Ground Source Heat Pump  

E-Print Network (OSTI)

In this study, the rectangular phase change storage tank (PCST) linked to a solar-aided ground source heat pump (SAGSHP) system is investigated experimentally and theoretically. The container of the phase change material (PCM) is the controlling...

Wang, F.; Zheng, M.; Li, Z.; Lei, B.

2006-01-01T23:59:59.000Z

400

Energy Conservation and Comfort of Heat Pump Desiccant Air Conditioning System in Actual Living Space in Summer  

E-Print Network (OSTI)

Energy Conservation and Comfort of Heat Pump Desiccant Air Conditioning System in Actual Living and total heat exchanger in terms of both energy conservation and thermal comfort in summer. 1. COP

Miyashita, Yasushi

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Dynamic Performance Study on the Solar Collector/Evaporator of Direct Expansion Solar Assisted Heat Pump Systems  

Science Journals Connector (OSTI)

A dynamic simulation model is developed for predicting performance of the solar collector/evaporator of direct expansion solar assisted heat pump systems. In this model, ... meteorological and configuration param...

Li Hong; Yang Hongxing

2009-01-01T23:59:59.000Z

402

High performance in low-flow solar domestic hot water systems  

SciTech Connect

Low-flow solar hot water heating systems employ flow rates on the order of 1/5 to 1/10 of the conventional flow. Low-flow systems are of interest because the reduced flow rate allows smaller diameter tubing, which is less costly to install. Further, low-flow systems result in increased tank stratification. Lower collector inlet temperatures are achieved through stratification and the useful energy produced by the collector is increased. The disadvantage of low-flow systems is the collector heat removal factor decreases with decreasing flow rate. Many solar domestic hot water systems require an auxiliary electric source to operate a pump in order to circulate fluid through the solar collector. A photovoltaic driven pump can be used to replace the standard electrical pump. PV driven pumps provide an ideal means of controlling the flow rate, as pumps will only circulate fluid when there is sufficient radiation. Peak performance was always found to occur when the heat exchanger tank-side flow rate was approximately equal to the average load flow rate. For low collector-side flow rates, a small deviation from the optimum flow rate will dramatically effect system performance.

Dayan, M.

1997-12-31T23:59:59.000Z

403

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

from controlling heat loss through the distribution pipes.distribution system configurations; a collection of analytical heat lossdistribution system configurations; a collection of analytical heat loss

Lutz, Jim

2012-01-01T23:59:59.000Z

404

Ecological and Economical efficient Heating and Cooling by innovative Gas Motor Heat Pump Systems and Solutions  

E-Print Network (OSTI)

#12;Ecological and Economical efficient Heating and Cooling by innovative Gas Motor Heat Pump use of buildings Gas Heat Pump Solution #12;Gas Heat Pump - deserves special attention due to its source in addition to the outside air ·A further essential component of Gas Heat Pump air conditioning

Oak Ridge National Laboratory

405

Matching of photovolatic motor-pump systems for maximum efficiency operation  

Science Journals Connector (OSTI)

A PV array is a nonlinear d.c. source and its operation has to be carefully matched to that of its equivalent electrical load in order to extract the maximum available energy. Two PV pumping schemes are investigated to get the maximum gross mechanical power. The system based on the separately-excited d.c. motor is matched through the control of the motor excitation, while for the system based on the induction motor, the voltage source inverter frequency is controlled by maximum mechanical power operation.

Aziza M. Zaki; Mona N. Eskander

1996-01-01T23:59:59.000Z

406

Industrial Heat Pumps: Where and When  

E-Print Network (OSTI)

pump analysis. INDUSTRIAL HEAT PUMPS: WHAT NEXT? There is definitely a need to develop heat pump systems with higher delivery temperatures. Chemical heat pumps (based on two-step endothermic/exothermic reactions) seem promising in this regard...

Ranade, S. M.; Chao, Y. T.

407

NREL: Learning - Pumped Hydropower  

NLE Websites -- All DOE Office Websites (Extended Search)

Pumped Hydropower Pumped Hydropower Pumped hydro facilities use off-peak electricity to pump water from a lower reservoir into one at a higher elevation. When the water stored in the upper reservoir is released, it is passed through hydraulic turbines to generate electricity. The off-peak electrical energy used to pump the water up hill can be stored indefinitely as gravitational energy in the upper reservoir. Thus, two reservoirs in combination can be used to store electrical energy for a long period of time, and in large quantities. Utilities generally prefer to operate large coal and nuclear power stations at full power all the time (referred to as "baseload generation"), so in the middle of the night, these plants often produce more power than is needed. Pumped hydro energy storage can be used to smooth out the demand

408

Photovoltaic array driven adjustable speed heat pump and power system scheme for a lunar based habitat  

SciTech Connect

A high reliability power system scheme, incorporating a photovoltaic power supply and adjustable speed heat pump for life support is presented in this paper. Initial design guidelines and also a description of the state of technology available is presented herein. The power supply scheme will be used as input to an Adjustable Speed Drive (ASD) which will be driving a heat pump. A brief study of various aspects of ASDs is presented, further a summary of the relative merits of different ASD systems presently in vogue is discussed. The advantages of using microcomputer based ASDs is widely understood and accepted. Of the three most popular drive systems, namely the Induction Motor Drive, Switched Reluctance Motor Drive and Brushless DC Motor Drive, any one may be chosen. The choice would depend on the nature of the application and its requirements. The suitability of the above mentioned drive systems and control techniques for a photovoltaic array driven ASD for an aerospace application are discussed. Also discussed are several possible power system designs for a potential lunar habitat.

Domijan, A. Jr.; Buchh, T.A. [Univ. of Florida, Gainesville, FL (United States). Dept. of Electrical and Computer Engineering] [Univ. of Florida, Gainesville, FL (United States). Dept. of Electrical and Computer Engineering

1998-12-01T23:59:59.000Z

409

Feasibility of combined solar thermal and ground source heat pump systems in cold climate, Canada  

Science Journals Connector (OSTI)

This document presents a study for examining the viability of hybrid ground source heat pump (GSHP) systems that use solar thermal collectors as the supplemental component in heating dominated buildings. Loads for an actual house in the City of Milton near Toronto, Canada, were estimated. TRNSYS, a system simulation software tool, was used to model yearly performance of a conventional GSHP system as well as a proposed hybrid GSHP system. Actual yearly data collected from the site were examined against the simulation results. This study demonstrates that hybrid ground source heat pump system combined with solar thermal collectors is a feasible choice for space conditioning for heating dominated houses. It was shown that the solar thermal energy storage in the ground could reduce a large amount of ground heat exchanger (GHX) length. Combining three solar thermal collectors with a total area of 6.81 m2 to a GSHP system will reduce GHX length by 15%. Sensitivity analysis was carried out for different cities of Canada and resulted that Vancouver, with mildest climate compared to other cities, was the best candidate for the proposed solar hybrid GSHP system with a GHX length reduction to solar collector area ratio of 7.64 m/m2. Overall system economic viability was also evaluated using a 20-year life-cycle cost analysis. The analysis showed that there is small economic benefit in comparing to the conventional GSHP system. The net present value of the proposed hybrid system based on the 20-year life-cycle cost analysis was estimated to be in a range of 3.7%–7.6% (or $1500 to $3430 Canadian dollar) lower than the conventional GSHP system depending on the drilling cost.

Farzin M. Rad; Alan S. Fung; Wey H. Leong

2013-01-01T23:59:59.000Z

410

Milli-Q Reference Water Purification System  

E-Print Network (OSTI)

Milli-Q® Reference Water Purification System The reference for ultrapure water systems EMD the requirements of the most demanding norms. We've achieved all this with a new purification strategy. Water. This water is sent through a small recirculation loop to the POD pak, where a final purification step

Woodall, Jerry M.

411

Development of a Procedure for the Predictive Control Strategy of a Chilled Water Storage System  

E-Print Network (OSTI)

-peak months to minimize demand charges. By optimizing the operation of the building air handling units (AHUs), chilled water pumps, chiller plant and the thermal storage system, the storage tank is better charged while chiller run time is reduced. Both on...

Wei, G.; Sakuri, Y.; Claridge, D. E.; Turner, W. D.; Liu, M.

2000-01-01T23:59:59.000Z

412

Experiments and thermal modeling on hybrid energy supply system of gas engine heat pumps and organic Rankine cycle  

Science Journals Connector (OSTI)

Abstract This paper presents a hybrid energy supply system, which is composed of two subsystems (gas engine-driven heat pump system (GEHP) and organic Rankine cycle system (ORC)) and three major thermodynamic cycles (the vapor compression refrigeration cycle, the internal combustion gas engine cycle and ORC). In order to convert the low-grade gas engine waste heat into high-grade electricity, the ORC system is built up using R245fa, \\{R152a\\} and R123 as working fluids, and the ORC thermal model is also developed. Meanwhile, experiments of \\{GHEPs\\} in cooling mode are conducted, and several factors which influence the cooling performance are also discussed. The results indicate that the cooling capacity, gas engine energy consumption, gas engine waste heat increase with increasing of gas engine speed and decrease with decreasing of evaporator water inlet temperature. The waste heat recovered from gas engine is more than 55% of gas engine energy consumption. F6urthermore, R123 in ORC system yields the highest thermal and exergy efficiency of 11.84% and 54.24%, respectively. Although, thermal and exergy efficiency of \\{R245fa\\} is 11.42% and 52.25% lower than that of R123, its environmental performance exhibits favorable utilization for ORC using gas engine waste heat as low-grade heat source.

Huanwei Liu; Qiushu Zhou; Haibo Zhao; Peifeng Wang

2015-01-01T23:59:59.000Z

413

Simulation Models for Improved Water Heating Systems  

E-Print Network (OSTI)

The DLM accounts for the distribution heat loss within eachHot-Water Distribution System Piping Heat Loss Factors—PhaseHot Water Distribution System Piping Heat Loss Factors-

Lutz, Jim

2014-01-01T23:59:59.000Z

414

Energy Engineering Analysis Program (EEAP), Fort Bliss Water Distribution System, Fort Bliss, El Paso, Texas  

SciTech Connect

The purpose of this study is to analyze the existing system and two alternate methods of peak electrical demand shaving for the water distribution system at Fort Bliss, Texas. The existing system will be referred to as Alternative Number 1 throughout the report. Alternative Number 2 includes the addition of water storage capacity in order to allow the well and booster pumps to operate only during non-peak electrical periods. Alternative Number 3 includes the use of natural gas powered electric generators at each well and booster pumping station. These generators would be utilized during the peak electrical periods. This report is prepared in accordance with the detailed scope of work for Contract No. DACA63-91-D-0048, Delivery Order 0005 (Refer to Appendix J for complete scope of work). The blast Life Cycle Cost In Design (LCCID) program with the ECIP option was used to determine the Life Cycle Cost (LCC) and Savings to Investment Ratio (SIR) for the analyzed retrofit for a 25 year study life. The existing water distribution system consists of 17 well pumps and 5 booster pumping stations. The desert field well and booster pumps were not included in this study due to their remote location. The well and booster pumps provide water supply to several ground elevated storage tanks located across the reservation (Refer to Appendix K for map indicating general locations). These storage tanks are located to provide three pressure zones. The upper pressure zone is maintained by a one million gallon tank. The intermediate pressure zone is maintained by a 0.6 million gallon tank. Pressure in the lower zone is maintained by three (3) elevated storage tanks.

NONE

1993-02-01T23:59:59.000Z

415

Requirements Analysis Study for Master Pump Shutdown System Project Development Specification [SEC 1 and 2  

SciTech Connect

This document has been updated during the definitive design portion of the first phase of the W-314 Project to capture additional software requirements and is planned to be updated during the second phase of the W-314 Project to cover the second phase of the Project's scope. The objective is to provide requirement traceability by recording the analysis/basis for the functional descriptions of the master pump shutdown system. This document identifies the sources of the requirements and/or how these were derived. Each requirement is validated either by quoting the source or an analysis process involving the required functionality, performance characteristics, operations input or engineering judgment.

BEVINS, R.R.

2000-03-24T23:59:59.000Z

416

Rate Setting for Small Water Systems  

E-Print Network (OSTI)

in detail the many resources that are available to help managers of small water systems make wise business decisions....

Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

2007-03-28T23:59:59.000Z

417

Water reactive hydrogen fuel cell power system  

DOE Patents (OSTI)

A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into the fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

Wallace, Andrew P; Melack, John M; Lefenfeld, Michael

2014-11-25T23:59:59.000Z

418

Water reactive hydrogen fuel cell power system  

DOE Patents (OSTI)

A water reactive hydrogen fueled power system includes devices and methods to combine reactant fuel materials and aqueous solutions to generate hydrogen. The generated hydrogen is converted in a fuel cell to provide electricity. The water reactive hydrogen fueled power system includes a fuel cell, a water feed tray, and a fuel cartridge to generate power for portable power electronics. The removable fuel cartridge is encompassed by the water feed tray and fuel cell. The water feed tray is refillable with water by a user. The water is then transferred from the water feed tray into a fuel cartridge to generate hydrogen for the fuel cell which then produces power for the user.

Wallace, Andrew P; Melack, John M; Lefenfeld, Michael

2014-01-21T23:59:59.000Z

419

Mining Gold from your Cooling Water System  

E-Print Network (OSTI)

to be achieved. GPM 2 /GPM 1 = RPM 2 /RPM 1 Equation (1) (RPM 2 /RPM 1 ) 3 = HP 2 /HP 1 Equation (2) ESL-IE-07-05-25 Proceedings from the Twenty-ninth Industrial Energy Technology Conference, New Orleans, LA, May 8-11, 2007. COOLING WATER PUMPING Pumping... Apr May Jun Jul Aug Sep Oct Nov Months Ri ver l eve l ( f t ) 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 T e mp er at ur e ( F) Average River Level Average River Temperature ESL-IE-07-05-25 Proceedings from the Twenty...

Mendez, T.

420

System of laser pump and synchrotron radiation probe microdiffraction to investigate optical recording process  

SciTech Connect

We have developed a system of laser-pump and synchrotron radiation probe microdiffraction to investigate the phase-change process on a nanosecond time scale of Ge{sub 2}Sb{sub 2}Te{sub 5} film embedded in multi-layer structures, which corresponds to real optical recording media. The measurements were achieved by combining (i) the pump-laser system with a pulse width of 300 ps, (ii) a highly brilliant focused microbeam with wide peak-energy width ({Delta}E/E {approx} 2%) made by focusing helical undulator radiation without monochromatization, and (iii) a precise sample rotation stage to make repetitive measurements. We successfully detected a very weak time-resolved diffraction signal by using this system from 100-nm-thick Ge{sub 2}Sb{sub 2}Te{sub 5} phase-change layers. This enabled us to find the dependence of the crystal-amorphous phase change process of the Ge{sub 2}Sb{sub 2}Te{sub 5} layers on laser power.

Yasuda, Nobuhiro; Fukuyama, Yoshimitsu; Osawa, Hitoshi [Research and Utilization Division, Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Kimura, Shigeru [Research and Utilization Division, Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Japan Science and Technology Agency, CREST, 5 Sanbancho, Chiyoda-ku, Tokyo 102-0075 (Japan); Ito, Kiminori; Tanaka, Yoshihito [RIKEN SPring-8 Center, RIKEN, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Matsunaga, Toshiyuki; Kojima, Rie; Hisada, Kazuya; Tsuchino, Akio; Birukawa, Masahiro [R and D Division, Panasonic Corporation, 3-4 Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237 (Japan); Yamada, Noboru [Department of Materials Science and Engineering, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto, Kyoto 606-8501 (Japan); Sekiguchi, Koji; Fujiie, Kazuhiko; Kawakubo, Osamu [Advanced Optical Storage Development Department, Advanced Device Technology Platform, Sony Corporation, 4-14-1 Asahi-cho, Atsugi, Kanagawa 243-0014 (Japan); Takata, Masaki [Research and Utilization Division, Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); RIKEN SPring-8 Center, RIKEN, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Department of Advanced Materials Science, School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan)

2013-06-15T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Boiler Upgrades and Decentralizing Steam Systems Save Water and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

replacing its central plant with a combination of distributed boilers and ground source heat pumps. The results saved more than 1 million MBtu in energy and 19,574 Kgal of water...

422

Characteristics of hydrostatic bearing/seal parts for water hydraulic pumps and motors. Part 1: Experiment and theory  

Science Journals Connector (OSTI)

In this study, the characteristics of disk-type hydrostatic thrust bearings supporting concentric loads, simulating the major bearing/seal parts of water hydraulic pumps and motors, are presented. The bearing is made up of a combination of stainless steel/stainless steel and stainless steel/plastics. The characteristics are evaluated by studying the relationships among the load-carrying capacity, pocket pressure, film thickness, and leakage flow rate. For the elastic material, Young’s modulus is a nonlinear relationship between stress acting on the seal surface and compressive strain. The load-carrying capacity expressed by the ratio of hydrostatic balance is not only dependent on the supply pressure (with the same restrictor) but also on the elastic modulus of materials. The calculated results coincide well with the experimental results.

X. Wang; A. Yamaguchi

2002-01-01T23:59:59.000Z

423

Heating and cooling performance analysis of a ground source heat pump system in Southern Germany  

Science Journals Connector (OSTI)

Abstract This paper examines thermal performance of a ground source heat pump (GSHP) system. The GSHP system was installed in an office building in Nuremberg city of Germany. In order to evaluate system performance the GSHP system has been continuously monitored for 4 years. Heating and cooling performance of the GSHP system is analyzed based on the accumulated data. Major findings of this work include: (1) coefficient of performance (COP) is estimated to be 3.9 for a typical winter day and energy efficiency ratio (EER) is assessed to be 8.0 for a typical summer day. These results indicate that the GSHP system has a higher efficiency for building cooling than building heating. (2) For a long-term period, the seasonal energy efficiency ratio (SEER) of the GSHP system is observed to increase by 8.7% annually, whereas the seasonal COP is decreased by 4.0% over a 4-year period. The heating and cooling performance of the GSHP system migrates in opposite trend is caused by the unevenly distributed heating and cooling load of the building. This phenomenon deserves serious attention in the design of future GSHP systems in order to avoid the reducing of energy efficiency over long-term operation.

Jin Luo; Joachim Rohn; Manfred Bayer; Anna Priess; Lucas Wilkmann; Wei Xiang

2015-01-01T23:59:59.000Z

424

Use of caged fish for mariculture and environmental monitoring in a power-plant cooling-water system  

E-Print Network (OSTI)

-nydrocarbon pesticides in fishes cultured at various locations within the cooling system. 203 LIST OF FIGURES Figure Page Map of the research site ~g the location of the power plant, cooling-water system, and research facilities 17 Schematic representation... quality might conceivably be available considering the large number of power plants utilizing coastal waters for cooling. Other important benefits of thermal fish-culture include ample water supply, and reduced pumping costs as a result of the massive...

Chamberlain, George William

2012-06-07T23:59:59.000Z

425

Analysis of Pump-Turbine S Instability and Reverse Waterhammer Incidents in Hydropower Systems  

SciTech Connect

Hydraulic systems continually experience dynamic transients or oscillations which threaten the hydroelectric plant from extreme water hammer pressures or resonance. In particular, the minimum pressure variations downstream of the turbine runner during the load rejection or other events may cause dangerous water column separation and subsequent rejoinder. Water column separation can be easily observed from the measurements of site transient tests, and has indeed caused serious historical damages to the machine and water conveyance system. Several technical issues regarding water column separation in draft tubes, including S instability of turbine characteristic curves, numerical instability and uncertainty of computer programs, are discussed here through case studies and available model and site test data. Catastrophic accidents experienced at a Kaplan turbine and in a long tailrace tunnel project, as well as other troubles detected in a more timely fashion, are revisited in order to demonstrate the severity of reverse water hammer. However, as there is no simple design solutions for such complex systems, this paper emphasizes that the design of hydraulic systems is always difficult, difficulties that are compounded when the phenomena in question are non-linear (water hammer), dynamic (involving wave interaction and complex devices of turbines, controls, and electrical systems), and non-monotonic (severity of response is seldom simply connected to severity of load as with vibrations and resonance, and the complexity of transient loads), and thus may lead to high economic and safety challenges and consequences.

Pejovic, Dr. Stanislav [University of Toronto] [University of Toronto; Zhang, Qin Fen [ORNL] [ORNL; Karney, Professor Byran W. [University of Toronto] [University of Toronto; Gajic, Prof. Aleksandar [University of Belgrade, Belgrade, Serbia] [University of Belgrade, Belgrade, Serbia

2011-01-01T23:59:59.000Z

426

Preliminary Analysis of a Solar Heat Pump System with Seasonal Storage for Heating and Cooling  

E-Print Network (OSTI)

and cooling were set up, which is responsible for the space heating and cooling and domestic hot water for a residential block. Through hourly simulation, the performance and the economics of such systems were analyzed, for the different tank volumes...

Yu, G.; Chen, P.; Dalenback, J.

2006-01-01T23:59:59.000Z

427

Illustrative Calculation of Economics for Heat Pump and "Grid...  

Energy Savers (EERE)

Illustrative Calculation of Economics for Heat Pump and "Grid-Enabled" Water Heaters Illustrative Calculation of Economics for Heat Pump and "Grid-Enabled" Water Heaters Rate...

428

Comparative study of power and water cogeneration systems  

Science Journals Connector (OSTI)

The performance of three combined systems using reverse osmosis to produce drinkable water and a Rankine cycle which produces mechanical power have been analyzed and compared. The RO subsystem incorporates a power recovery unit (a hydraulic turbine in the first two cases and a pressure exchange unit in the third case). The coupling between the RO and Rankine subsystems is only mechanical in the first case (the Rankine cycle provides mechanical power to the pumps of the RO subsystem), while in the two other cases the coupling is both mechanical and thermal (the heat rejected by the condenser of the Rankine cycle is transferred to the seawater). The minimum values of the Rankine cycle mass ratio for the three systems and the maximum operating temperature for the two last systems have been established. Energy and exergy efficiencies are also compared for identical entering parameters.

N. Bouzayani; N. Galanis; J. Orfi

2007-01-01T23:59:59.000Z

429

High-speed pumping to UHV  

Science Journals Connector (OSTI)

Development of a high-speed pumping system for ultra high vacuum (UHV) process dose not reduce only cost and waiting time for experiment and production, but also reduces CO2 emission that is known as one of the serious causes in the global warming problem. Reduction of vapor water concentration in a purge gas line would be one of the most effective measures to reduce pumping time to UHV. We carried out control of water vapor in a nitrogen gas purge line in addition to surface treatments of chambers using buff polishing and electrolytic polishing, followed by measurement of outgassing rate of the chambers. Under the reasonable control of the water vapor, the pumping time to reach the pressure of 1 × 10?6 Pa was able to be shortened with two orders of the magnitude. And it was also found that the main residual gas in the chamber was hydrogen after pumping down with the low concentration of water vapor. The quality of residual gas was equivalent to the quality in a baked UHV system. The introduction of well controlled nitrogen gas to the vacuum system which was not baked out during its pumping has proved a pressure of 3 × 10?8 Pa for 24 h in the chamber without orifice.

Ko Yamazaki; Junichi Shike; Motoi Yamagata; Masahiro Kitano; Michiru Nishiwaki; Shigeki Kato

2009-01-01T23:59:59.000Z

430

Carbon and Water Resource Management for Water Distribution Systems  

E-Print Network (OSTI)

were evaluated using different energy mixes consisting of aon the embodied energy and electricity mix as defined by the5.8 Pumping Energy The electricity mix for pumping energy

Hendrickson, Thomas Peter

2013-01-01T23:59:59.000Z

431

Analysis of Selection of Single or Double U-bend Pipes in a Ground Source Heat Pump System  

E-Print Network (OSTI)

The ground source heat pump (GSHP) system is widely used because of its energy-saving and environmental-friendly characteristics. The buried pipes heat exchangers play an important role in the whole GSHP system design. However, in most cases, single...

Shu, H.; Duanmu, L.; Hua, R.

2006-01-01T23:59:59.000Z

432

Study of the design Method of an Efficient Ground Source Heat Pump Thermal Source System in a Cold Area  

E-Print Network (OSTI)

The ground source heat pump (GSHP) system-an energy efficiency and environment friendly system-is becoming popular in many parts of China. However, an imbalance usually exists between the annual heat extracted from and rejected to the ground due...

Shu, H.; Duanmu, L.; Hua, R.; Zou, Y.; Du, G.

2006-01-01T23:59:59.000Z

433

Geothermal Heat Pump System for the New 500-bed 200,000 SF Student Housing Project at the University at Albanys Main Campus  

Energy.gov (U.S. Department of Energy (DOE))

This project proposes to heat and cool planned 500-bed apartment-style student housing with closed loop vertical bore geothermal heat pump system installation.

434

Ductless, Mini-Split Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless, Mini-Split Heat Pump Basics Ductless, Mini-Split Heat Pump Basics Ductless, Mini-Split Heat Pump Basics August 19, 2013 - 11:04am Addthis Ductless, mini-split-system heat pumps (mini splits), as their name implies, do not have ducts. Therefore, they make good retrofit add-ons to houses or buildings with "non-ducted" heating systems, such as hydronic (hot water heat), radiant panels, and space heaters (wood, kerosene, propane). They can also be a good choice for room additions, where extending or installing distribution ductwork is not feasible. How Ductless, Mini-Split Heat Pumps Work Like standard air-source heat pumps, mini splits have two main components: an outdoor compressor/condenser, and an indoor air-handling unit. A conduit, which houses the power cable, refrigerant tubing, suction tubing,

435

Ductless, Mini-Split Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless, Mini-Split Heat Pumps Ductless, Mini-Split Heat Pumps Ductless, Mini-Split Heat Pumps June 24, 2012 - 4:19pm Addthis What does this mean for me? You can take advantage of the fact that -- unlike earlier versions -- newer models of ductless mini-split heat pumps operate effectively in cold temperatures. If you are building an addition or doing a major remodel and your home does not have heating and cooling ducts, a ductless mini-split heat pump may be a cost-effective, energy-efficient choice. Ductless, mini-split-system heat pumps (mini splits) make good retrofit add-ons to houses with "non-ducted" heating systems, such as hydronic (hot water heat), radiant panels, and space heaters (wood, kerosene, propane). They can also be a good choice for room additions where extending or

436

Carbon and Water Resource Management for Water Distribution Systems  

E-Print Network (OSTI)

wastewater transmission and sewage treatment. Distribution pumping and sewage treatment were found to contribute the most to climate change

Hendrickson, Thomas Peter

2013-01-01T23:59:59.000Z

437

Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pumps Heat Pumps Heat Pumps Geothermal heat pumps are expensive to install but pay for themselves over time in reduced heating and cooling costs. Learn more about how geothermal heat pumps heat and cool buildings by concentrating the naturally existing heat contained within the earth -- a clean, reliable, and renewable source of energy. In moderate climates, heat pumps can be an energy-efficient alternative to furnaces and air conditioners. Several types of heat pumps are available, including air-source; geothermal; ductless, mini-split; and absorption heat pumps. Learn more about the different options and how to use your heat pump efficiently to save money and energy at home. Featured Heat Pump Systems A heat pump can provide an alternative to using your air conditioner. | Photo courtesy of iStockPhoto/LordRunar.

438

Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Rebate Program Kosciusko REMC - Residential Geothermal and Air-source Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Maximum Rebate Maximum of two rebates per household Program Info State Indiana Program Type Utility Rebate Program Rebate Amount Geothermal System: $250 Air-Source Heat Pump: $150 Electric Water Heater: $75 - $125 Provider Kosciusko REMC Kosciusko REMC offers rebates (as bill credits) to residential members for the purchase and installation of high efficiency air-source heat pumps, geothermal heat pumps, and electric water heaters. For each purchase of an

439

Optimization of Chilled Water Systems  

E-Print Network (OSTI)

the absorption chiller has the least increase in COP per degree change in supply water. METHODS OF IMPLEMENTATION Using Space Conditions. (Figure 2). By evaluating the performance of all the cooling coils through a selector switch, then establishing.....::::.....L-...L-....L..-...L..-+--"""---.L.--"----"------1 15~--1---~-+---+---+---+-7' Reciprocating Absorption 40 c Leaving chIlled water temperature - C F Fig. 1 Effect of chilled water temperature on chiller coefficient of performance Using Return Water Temperature. (Figure 3). This method...

Gidwani, B. N.

440

Green Systems Solar Hot Water  

E-Print Network (OSTI)

,2; basement) Pre-heats water so water heaters don't need to use as much energy Gas-powered, high efficiency heated water before it is circulated through the building Two gas boilers (GWB-1,2; basement) can be used

Schladow, S. Geoffrey

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Foundation heat exchangers for residential ground source heat pump systems Numerical modeling and experimental validation  

SciTech Connect

A new type of ground heat exchanger that utilizes the excavation often made for basements or foundations has been proposed as an alternative to conventional ground heat exchangers. This article describes a numerical model that can be used to size these foundation heat exchanger (FHX) systems. The numerical model is a two-dimensional finite-volume model that considers a wide variety of factors, such as soil freezing and evapotranspiration. The FHX numerical model is validated with one year of experimental data collected at an experimental house located near Oak Ridge, Tennessee. The model shows good agreement with the experimental data-heat pump entering fluid temperatures typically within 1 C (1.8 F) - with minor discrepancies due to approximations, such as constant moisture content throughout the year, uniform evapotranspiration over the seasons, and lack of ground shading in the model.

Xing, Lu [Oklahoma State University; Cullin, James [Oklahoma State University; Spitler, Jeffery [Oklahoma State University; Im, Piljae [ORNL; Fisher, Daniel [Oklahoma State University

2011-01-01T23:59:59.000Z

442

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions  

SciTech Connect

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2012-01-01T23:59:59.000Z

443

A Simple and Quick Chilled Water Loop Balancing for Variable Flow System  

E-Print Network (OSTI)

. It was built in 1995 with a modem EMCS control for the HVAC systems. The building was mostly occupied in late 1996. The whole complex primarily consists of outpatient clinic rooms, pharmacy, nuclear medicine, ICUs, CCUs, surgical areas, inpatient beds... the building owner, facility engineers or HVAC operators more opportunities to run the chilled water system more efficiently. Generally, the pump speeds are controlled by the EMCS or a stand-alone controller to maintain the differential pressure setpoints...

Zhu, Y.; Batten, T.; Turner, W. D.; Claridge, D. E.; Liu, M.

2000-01-01T23:59:59.000Z

444

Application Study of the Pump Water Flow Station for Building Energy Consumption Monitoring and Control Optimization  

E-Print Network (OSTI)

. For example, the Venturi meter is commonly used for steam flow measurement, but it is less commonly used for water flow measurement because of the poor accuracy at low flow rates and high installation cost. 2) Displacement flow meter: The meter works... by using the fluid to rotate or displace a device inserted into the flow stream, e.g., a turbine flow meter, tangential paddlewheel meter, etc. It causes extra pressure drop. The bearing wears out and calibration is often needed to ensure accuracy...

Liu, G.; Liu, M.

2006-01-01T23:59:59.000Z

445

Study of integrated metal hydrides heat pump and cascade utilization of liquefied natural gas cold energy recovery system  

Science Journals Connector (OSTI)

The traditional cold energy utilization of the liquefied natural gas system needs a higher temperature heat source to improve exergy efficiency, which barricades the application of the common low quality thermal energy. The adoption of a metal hydride heat pump system powered by low quality energy could provide the necessary high temperature heat and reduce the overall energy consumption. Thus, an LNG cold energy recovery system integrating metal hydride heat pump was proposed, and the exergy analysis method was applied to study the case. The performance of the proposed integration system was evaluated. Moreover, some key factors were also theoretically investigated about their influences on the system performance. According to the results of the analysis, some optimization directions of the integrated system were also pointed out.

Xiangyu Meng; Feifei Bai; Fusheng Yang; Zewei Bao; Zaoxiao Zhang

2010-01-01T23:59:59.000Z

446

Infusion Pump Informatics IMPACT STATEMENT  

E-Print Network (OSTI)

Infusion Pump Informatics NEED IMPACT STATEMENT INITIATIVE Working with Purdue's Rosen Center for Advanced Computing, RCHE developed the Infusion Pump Informatics (IPI) System. IPI member hospitals upload their infusion pump alert data to the system each month. The system is web-based and highly interactive. Drawing

Ginzel, Matthew

447

John Snow Cholera Map as Rectified Raster Data, Water Pump Location Data, Deaths by Building Data  

E-Print Network (OSTI)

John Snow’s investigation of cholera in 1850s London used analysis techniques that would now likely entail use of geographic information systems (GIS), as well as laying the foundation for modern epidemiology. Snow’s ...

Houser, Rhonda

2013-01-31T23:59:59.000Z

448

Electric equipment providing space conditioning, water heating, and refrigeration consumes 12.5% of the nation's  

E-Print Network (OSTI)

Electric equipment providing space conditioning, water heating, and refrigeration consumes 12 are the heart of air conditioners, heat pumps, chillers, supermarket refrigeration systems, and more. Global use of vapor compression system configurations including multi-functional integrated heat pumps, multi

Oak Ridge National Laboratory

449

Public Health Issues Associated with Small Drinking Water Systems  

E-Print Network (OSTI)

Public Health Issues Associated with Small Drinking Water Systems Not Regulated by the Safe Drinking Water Act From: Nonfederally Regulated Drinking Water Systems: State and Local Public Health ...........................................................................................5 Priority Environmental Public Health Challenges for Small Drinking Water Systems

450

Pump8  

NLE Websites -- All DOE Office Websites (Extended Search)

Preferred Upstream Management Practices Preferred Upstream Management Practices Rewriting the Meaning of "Standard Business Practices" PUMP U.S. Department of Energy * National Energy Technology Laboratory TECHNOLOGY TRANSFER TO THE USER * Regional Production Obstacles: Identification of specific regional obstacles to oil production, and the preferred management practices to overcome the problems. Demonstrate drilling, field opera- tions technology, reservoir man- agement approaches, computer tools, or better ways to comply with environmental regulations in a case study. * Research Groups or Councils: Use established groups or councils in a region to formulate the "best practices" appropriate to that region. The goal is to develop a self- sustaining system to identify pro- duction constraints and solve them

451

Energy 101: Geothermal Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy 101: Geothermal Heat Pumps Energy 101: Geothermal Heat Pumps Energy 101: Geothermal Heat Pumps January 4, 2011 - 12:15pm Addthis An energy-efficient heating and cooling alternative, the geothermal heat pump system moves heat from the ground to a building (or from a building to the ground) through a series of flexible pipe "loops" containing water. This edition of Energy 101 explores the benefits Geothermal and the science behind how it all comes together. John Schueler John Schueler Former New Media Specialist, Office of Public Affairs Quick Facts Heat pump systems can lower energy bills by up to 70% over traditional types of heating systems. During this time of year, many homeowners are searching for ways to reduce steep heating costs. One of the options they should consider during the

452

Energy 101: Geothermal Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy 101: Geothermal Heat Pumps Energy 101: Geothermal Heat Pumps Energy 101: Geothermal Heat Pumps January 4, 2011 - 12:15pm Addthis An energy-efficient heating and cooling alternative, the geothermal heat pump system moves heat from the ground to a building (or from a building to the ground) through a series of flexible pipe "loops" containing water. This edition of Energy 101 explores the benefits Geothermal and the science behind how it all comes together. John Schueler John Schueler Former New Media Specialist, Office of Public Affairs Quick Facts Heat pump systems can lower energy bills by up to 70% over traditional types of heating systems. During this time of year, many homeowners are searching for ways to reduce steep heating costs. One of the options they should consider during the

453

The Well-Group Distribution of Groundwater Source Heat Pump System Optimized Research  

E-Print Network (OSTI)

It is the key question that how does the well group arrange for application of GWSHP system. Based on the fact that the water movement is the important factor of heat transfer on aquifer, this paper presents two steps analysis method and analyze...

Liu, Z.; Lu, L.; Yoshida, H.

2006-01-01T23:59:59.000Z

454

Optimal Well-Group Distribution of a Groundwater Source Heat Pump System  

E-Print Network (OSTI)

It is critical to determine how the well group arranges for application of the GWSHP system. Based on the fact that water movement is the most important factor influencing heat transfer in an aquifer, this paper presents a two-step analysis method...

Liu, Z.; Lu, L.; Yoshida, H.

2006-01-01T23:59:59.000Z

455

A solid polymer water electrolysis system utilizing natural circulation  

Science Journals Connector (OSTI)

Abstract Solid Polymer Water Electrolysis (SPWE) is a method to efficiently produce high-purity hydrogen gas using a polymer electrolyte membrane-based system. SPWE systems that utilize natural water circulation (resulting from a difference in buoyancy) are a promising technology, which need no additional circulation pump for water supply to the electrolysis cells, and generate no pressure difference between the hydrogen generation and oxygen generation chambers. However, despite not needing an accurate pressure control, gas bubbles formed and trapped within the cell stacks can inhibit heat convection, leading to hot-spot formation and consequent destructive degradation. Improving the reliability is therefore one of the most important technological issues in natural circulation SPWEs. In this study, hot-spot formation is studied both by numerical heat and flow analysis, and by experimental in-situ visualization. This leads to insights into the degradation mechanisms of SPWE stacks, and their possible solutions. An improved design for an SPWE cell stack is successfully fabricated, and reliable operation up to 5000 h is demonstrated.

Yoshinori Kobayashi; Kenichiro Kosaka; Takashi Yamamoto; Yuya Tachikawa; Kohei Ito; Kazunari Sasaki

2014-01-01T23:59:59.000Z

456

Screening reactor steam/water piping systems for water hammer  

SciTech Connect

A steam/water system possessing a certain combination of thermal, hydraulic and operational states, can, in certain geometries, lead to a steam bubble collapse induced water hammer. These states, operations, and geometries are identified. A procedure that can be used for identifying whether an unbuilt reactor system is prone to water hammer is proposed. For the most common water hammer, steam bubble collapse induced water hammer, six conditions must be met in order for one to occur. These are: (1) the pipe must be almost horizontal; (2) the subcooling must be greater than 20 C; (3) the L/D must be greater than 24; (4) the velocity must be low enough so that the pipe does not run full, i.e., the Froude number must be less than one; (5) there should be void nearby; (6) the pressure must be high enough so that significant damage occurs, that is the pressure should be above 10 atmospheres. Recommendations on how to avoid this kind of water hammer in both the design and the operation of the reactor system are made.

Griffith, P. [Massachusetts Inst. of Tech., Cambridge, MA (United States)

1997-09-01T23:59:59.000Z

457

Trim or Replace Impellers on Oversized Pumps  

Energy.gov (U.S. Department of Energy (DOE))

This tip sheet discusses the reasoning behind trimming or replacing impellers on oversized pumps and describes how it works to improve pumping system efficiency.

458

Human Health Science Building Geothermal Heat Pumps  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HUMAN HEALTH SCIENCE BLDG GEO HEAT PUMP SYSTEMS Principal Investigator Source Heat Pumps Demo Projects May 20, 2010 This presentation does not contain any proprietary confidential,...

459

Building America Webinar: Central Multifamily Water Heating Systems- Multifamily Central Heat Pump Water Heating  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was delivered at the U.S. Department of Energy Building America webinar on January 21, 2015.

460

Emergy Synthesis and Its Application on Water Efficiency of Water Ecological-Economic System  

Science Journals Connector (OSTI)

Water ecological-economic system (WEES) is a coupling system of traditional water resource system (WS) and eco-environment, social economy system. Water efficiency is an important index and comprehensively reflec...

Cuimei Lv; Minhua Ling

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Absorption Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Absorption Heat Pump Basics Absorption Heat Pump Basics Absorption Heat Pump Basics August 19, 2013 - 11:11am Addthis Absorption heat pumps are essentially air-source heat pumps driven not by electricity, but by a heat source such as natural gas, propane, solar-heated water, or geothermal-heated water. Because natural gas is the most common heat source for absorption heat pumps, they are also referred to as gas-fired heat pumps. There are also absorption coolers available that work on the same principal, but are not reversible and cannot serve as a heat source. These are also called gas-fired coolers. How Absorption Heat Pumps Work Residential absorption heat pumps use an ammonia-water absorption cycle to provide heating and cooling. As in a standard heat pump, the refrigerant (in this case, ammonia) is condensed in one coil to release its heat; its

462

Absorption Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Absorption Heat Pumps Absorption Heat Pumps Absorption Heat Pumps June 24, 2012 - 2:11pm Addthis Absorption heat pumps are essentially air-source heat pumps driven not by electricity, but by a heat source such as natural gas, propane, solar-heated water, or geothermal-heated water. Because natural gas is the most common heat source for absorption heat pumps, they are also referred to as gas-fired heat pumps. There are also absorption (or gas-fired) coolers available that work on the same principle. Unlike some absorption heat pumps, however, these are not reversible and cannot serve as a heat source. Residential absorption heat pumps use an ammonia-water absorption cycle to provide heating and cooling. As in a standard heat pump, the refrigerant (in this case, ammonia) is condensed in one coil to release its heat; its

463

Absorption Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Absorption Heat Pumps Absorption Heat Pumps Absorption Heat Pumps June 24, 2012 - 2:11pm Addthis Absorption heat pumps are essentially air-source heat pumps driven not by electricity, but by a heat source such as natural gas, propane, solar-heated water, or geothermal-heated water. Because natural gas is the most common heat source for absorption heat pumps, they are also referred to as gas-fired heat pumps. There are also absorption (or gas-fired) coolers available that work on the same principle. Unlike some absorption heat pumps, however, these are not reversible and cannot serve as a heat source. Residential absorption heat pumps use an ammonia-water absorption cycle to provide heating and cooling. As in a standard heat pump, the refrigerant (in this case, ammonia) is condensed in one coil to release its heat; its

464

Ignition reactor and pump pulse parameters in a reactor–laser system  

Science Journals Connector (OSTI)

The experience gained in operating a demonstration nuclear-pumped laser in stand B (Physics and Power- Engineering Institute (FEI)) with a pulsed ignition reactor based on the 235U BARS-6 reactor is analyzed. It ...

P. P. D’yachenko; G. N. Fokin

2012-09-01T23:59:59.000Z

465

[Waste water heat recovery system  

SciTech Connect

The production capabilities for and field testing of the heat recovery system are described briefly. Drawings are included.

Not Available

1993-04-28T23:59:59.000Z

466

Resources for Small Water Systems in Texas  

E-Print Network (OSTI)

supply and wastewater treatment projects through state bonds and federal grants. TWDB administers the Economically Distressed Areas Program (EDAP), which provides fi nancial assistance to eligible counties and communities. Some counties are eligible.... The U.S. Department of Agriculture Rural Utilities Service has a Water and Wastewater Disposal Program that gives loans and grants to water systems in rural areas and to towns with fewer than 10,000 people. Emergency Community Water Assistance...

Dozier, Monty; Theodori, Gene L.; Jensen, Ricard

2007-03-28T23:59:59.000Z

467

Residential hot water distribution systems: Roundtablesession  

SciTech Connect

Residential building practice currently ignores the lossesof energy and water caused by the poor design of hot water systems. Theselosses include: combustion and standby losses from water heaters, thewaste of water (and energy) while waiting for hot water to get to thepoint of use; the wasted heat as water cools down in the distributionsystem after a draw; heat losses from recirculation systems and thediscarded warmth of waste water as it runs down the drain. Severaltechnologies are available that save energy (and water) by reducing theselosses or by passively recovering heat from wastewater streams and othersources. Energy savings from some individual technologies are reported tobe as much as 30 percent. Savings calculations of prototype systemsincluding bundles of technologies have been reported above 50 percent.This roundtable session will describe the current practices, summarizethe results of past and ongoing studies, discuss ways to think about hotwater system efficiency, and point to areas of future study. We will alsorecommend further steps to reduce unnecessary losses from hot waterdistribution systems.

Lutz, James D.; Klein, Gary; Springer, David; Howard, Bion D.

2002-08-01T23:59:59.000Z

468

Passive safety injection system using borated water  

DOE Patents (OSTI)

A passive safety injection system relies on differences in water density to induce natural circulatory flow patterns which help maintain prescribed concentrations of boric acid in borated water, and prevents boron from accumulating in the reactor vessel and possibly preventing heat transfer.

Conway, Lawrence E. (Allegheny, PA); Schulz, Terry L. (Westmoreland, PA)

1993-01-01T23:59:59.000Z

469

Robot design for leak detection in water-pipe systems  

E-Print Network (OSTI)

Leaks are major problem that occur in the water pipelines all around the world. Several reports indicate loss of around 20 to 30 percent of water in the distribution of water through water pipe systems. Such loss of water ...

Choi, Changrak

2012-01-01T23:59:59.000Z

470

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network (OSTI)

Comparison of energy efficiency between variable refrigeranttheir superior energy efficiency. The variable refrigerantfew studies reporting the energy efficiency of VRF systems

Hong, Tainzhen

2010-01-01T23:59:59.000Z

471

SYSTEM OPTIMIZTION OF HOT WATER CONCENTRATED SOLAR THERMOELECTRIC GENERATION  

E-Print Network (OSTI)

In this report, we describe the design of a concentrated solar thermoelectric (TE) system which can provide both electricity and hot water. Today’s thermoelectric materials have a relatively low efficiency (~6 % for temperature difference across the thermoelement on the order of 300 o C). However since thermoelectrics don’t need their cold side to be near room temperature, (in another word, one can chose the particular thermoelectric material to match to the operational temperature) it is possible to use the waste heat to provide hot water and this makes the overall efficiency of the combined system to be quite high. A key factor in the optimization of the thermoelectric module is the thermal impedance matching with the incident solar radiation, and also with the hot water heat exchanger on the cold side of the thermoelectric module. We have developed an analytic model for the whole system and optimized each component in order to minimize the material cost. TE element fill factor is found to be an important parameter to optimize at low solar concentrations (generated per mass of the thermoelectric elements. Similarly the co-optimization of the microchannel heat exchanger and the TE module can be used to minimize the amount of material in the heat exchanger and the pumping power required for forced convection liquid cooling. Changing the amount of solar concentration, changes the input heat flux and this is another parameter that can be optimized in order to reduce the cost of heat exchanger (by size), the tracking requirement and the whole system. A series of design curves for different solar concentration are obtained. It is shown that the overall efficiency of the system can be more than 80 % at 200x concentration which is independent of the material ZT (TE figure-of-merit). For a material with ZThot~0.9, the electrical conversion efficiency is ~10%. For advanced materials with ZThot ~ 2.8, the electrical conversion efficiency could reach ~21%. 1.

Kazuaki Yazawa; Ali Shakouri

472

Renewable Energy Powered Water Treatment Systems   

E-Print Network (OSTI)

There are many motivations for choosing renewable energy technologies to provide the necessary energy to power water treatment systems for reuse and desalination. These range from the lack of an existing electricity grid, ...

Richards, Bryce S.; Schäfer, Andrea

2009-01-01T23:59:59.000Z

473

INTEGRATED WATER TREATMENT SYSTEM PERFORMANCE EVALUATION  

SciTech Connect

This document describes the results of an evaluation of the current Integrated Water Treatment System (IWTS) operation against design performance and a determination of short term and long term actions recommended to sustain IWTS performance.

SEXTON RA; MEEUWSEN WE

2009-03-12T23:59:59.000Z

474

Indexes of pumps for oil field pumping units  

SciTech Connect

As reported previously, a series of oil field pumping units has been developed with power outputs of 125, 250, 500, and 1000 kW, designed for injecting working fluids in cementing operations in oil and gas wells, hydraulic fracturing of formations, washing out sand plugs, and other production operations. The units are designed for the use of three-plunger pumps with individual power outputs of 125 or 500 kW. In the 250- and 1000-kW units, two such pumps are used. The 1000-kW pumping unit serves mainly for deep-penetration hydraulic fracturing of formations, and also for fracturing deep formations. The hydraulic fracturing process does not require the use of units with two pumps; this has been demonstrated by experience, both here and in other countries. All units intended for use in hydraulic fracturing are built with a single pump, transmission, and drive. Pumping units for well cementing must have two pumps that will give a high delivery rate. At the start of the operation, a single pump can be used to feed water into the cement mixer, with the second pump used to transfer the cement slurry to the well. Then both pumps are connected to the slurry injection line. The operation of these pumps is described.

Ibragimov, E.S.

1995-07-01T23:59:59.000Z

475

Microhydropower Turbine, Pump, and Waterwheel Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Microhydropower Turbine, Pump, and Waterwheel Basics Microhydropower Turbine, Pump, and Waterwheel Basics Microhydropower Turbine, Pump, and Waterwheel Basics August 16, 2013 - 3:58pm Addthis A microhydropower system needs a turbine, pump, or waterwheel to transform the energy of flowing water into rotational energy, which is then converted into electricity. Turbines Turbines are commonly used to power microhydropower systems. The moving water strikes the turbine blades, much like a waterwheel, to spin a shaft. But turbines are more compact in relation to their energy output than waterwheels. They also have fewer gears and require less material for construction. There are two general types of turbines: impulse and reaction. Impulse Turbines Impulse turbines, which have the least complex design, are most commonly

476

Microhydropower Turbine, Pump, and Waterwheel Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Microhydropower Turbine, Pump, and Waterwheel Basics Microhydropower Turbine, Pump, and Waterwheel Basics Microhydropower Turbine, Pump, and Waterwheel Basics August 16, 2013 - 3:58pm Addthis A microhydropower system needs a turbine, pump, or waterwheel to transform the energy of flowing water into rotational energy, which is then converted into electricity. Turbines Turbines are commonly used to power microhydropower systems. The moving water strikes the turbine blades, much like a waterwheel, to spin a shaft. But turbines are more compact in relation to their energy output than waterwheels. They also have fewer gears and require less material for construction. There are two general types of turbines: impulse and reaction. Impulse Turbines Impulse turbines, which have the least complex design, are most commonly

477

Distribution of bacteria within operating laboratory water purification systems.  

Science Journals Connector (OSTI)

...within operating laboratory water purification systems. G A McFeters S C...within operating laboratory water purification systems. | Experiments were...within Operating Laboratory Water Purification Systems GORDON A. McFETERS...

G A McFeters; S C Broadaway; B H Pyle; Y Egozy

1993-05-01T23:59:59.000Z

478

Tips: Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pumps Heat Pumps Tips: Heat Pumps June 24, 2013 - 5:48pm Addthis Heat pumps can be a cost-effective choice in moderate climates, especially if you heat your home with electricity. Heat pumps can be a cost-effective choice in moderate climates, especially if you heat your home with electricity. Heat pumps are the most efficient form of electric heating in moderate climates. Because they move heat rather than generate heat, heat pumps can provide equivalent space conditioning at as little as one quarter of the cost of operating conventional heating or cooling appliances. A heat pump does double duty as a central air conditioner by collecting the heat inside your house and pumping it outside. There are three types of heat pumps: air-to-air, water source, and geothermal. They collect heat from the air, water, or ground outside your

479

Combined cooling and purification system for nuclear reactor spent fuel pit, refueling cavity, and refueling water storage tank  

DOE Patents (OSTI)

The spent fuel pit of a pressured water reactor (PWR) nuclear power plant has sufficient coolant capacity that a safety rated cooling system is not required. A non-safety rated combined cooling and purification system with redundant branches selectively provides simultaneously cooling and purification for the spent fuel pit, the refueling cavity, and the refueling water storage tank, and transfers coolant from the refueling water storage tank to the refueling cavity without it passing through the reactor core. Skimmers on the suction piping of the combined cooling and purification system eliminate the need for separate skimmer circuits with dedicated pumps.

Corletti, Michael M. (New Kensington, PA); Lau, Louis K. (Monroeville, PA); Schulz, Terry L. (Murrysville Boro, PA)

1993-01-01T23:59:59.000Z

480

Designing a 'Near Optimum' Cooling-Water System  

E-Print Network (OSTI)

Cooling water is expensive to circulate. Reducing its flow - i.e., hiking exchanger outlet temperatures - can cut tower, pump and piping investment as much as one-third and operating cost almost in half. Heat-exchanger-network optimization has been...

Crozier, R. A., Jr.

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water pumping systems" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Ground-source Heat Pumps Applied to Commercial Buildings  

SciTech Connect

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

Parker, Steven A.; Hadley, Donald L.

2009-07-14T23:59:59.000Z

482

Ground-Source Heat Pumps Applied to Commercial Buildings  

SciTech Connect

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

Parker, Steven A.; Hadley, Donald L.

2006-12-31T23:59:59.000Z

483

Vulnerability assessment of water supply systems for insufficient fire flows  

E-Print Network (OSTI)

and Data Acquisition (SCADA) systems. Generally speaking, SCADA systems are the monitoring and control systems in the utility industries which help in operating the water system components with proper timing and sequence, measuring water quality... parameters, etc., without physically accessing the network. Thus, SCADA systems can reduce operating cost for a water utility and thereby increase a water system?s efficiency. The proposed hardening methodology of the water supply system was based...

Kanta, Lufthansa Rahman

2009-05-15T23:59:59.000Z

484

Luminescent light source for laser pumping and laser system containing same  

DOE Patents (OSTI)

The invention relates to a pumping lamp for use with lasers comprising a porous substrate loaded with a component capable of emitting light upon interaction of the component with exciting radiation and a source of exciting radiation. Preferably, the pumping lamp comprises a source of exciting radiation, such as an electron beam, and an aerogel or xerogel substrate loaded with a component capable of interacting with the exciting radiation, e.g., a phosphor, to produce light, e.g., visible light, of a suitable band width and of a sufficient intensity to generate a laser beam from a laser material.

Hamil, Roy A. (Tijeras, NM); Ashley, Carol S. (Albuquerque, NM); Brinker, C. Jeffrey (Albuquerque, NM); Reed, Scott (Albuquerque, NM); Walko, Robert J. (Albuquerque, NM)

1994-01-01T23:59:59.000Z

485

Webinar: ENERGY STAR Hot Water Systems for High Performance Homes...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Webinar: ENERGY STAR Hot Water Systems for High Performance Homes Webinar: ENERGY STAR Hot Water Systems for High Performance Homes This presentation is from the Building America...

486

Energy 101: Geothermal Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Geothermal Heat Pumps Geothermal Heat Pumps Energy 101: Geothermal Heat Pumps Addthis Description An energy-efficient heating and cooling alternative, the geothermal heat pump system moves heat from the ground to a building (or from a building to the ground) through a series of flexible pipe "loops" containing water. This edition of Energy 101 explores the benefits Geothermal and the science behind how it all comes together. Duration 2:32 Topic Tax Credits, Rebates, Savings Heating & Cooling Geothermal Consumption Credit Energy Department Video MR. : We all want to save money heating or cooling our house or office, right? The answer may be under your feet, literally. Much of the heating and cooling can come from the ground, below the surface, with something called a geothermal heat pump. You see, below the frost line

487

Nuclear reactor with makeup water assist from residual heat removal system  

DOE Patents (OSTI)

A pressurized water nuclear reactor uses its residual heat removal system to make up water in the reactor coolant circuit from an in-containment refueling water supply during staged depressurization leading up to passive emergency cooling by gravity feed from the refueling water storage tank, and flooding of the containment building. When depressurization commences due to inadvertence or a manageable leak, the residual heat removal system is activated manually and prevents flooding of the containment when such action is not necessary. Operation of the passive cooling system is not impaired. A high pressure makeup water storage tank is coupled to the reactor coolant circuit, holding makeup coolant at the operational pressure of the reactor. The staged depressurization system vents the coolant circuit to the containment, thus reducing the supply of makeup coolant. The level of makeup coolant can be sensed to trigger opening of successive depressurization conduits. The residual heat removal pumps move water from the refueling water storage tank into the coolant circuit as the coolant circuit is depressurized, preventing reaching the final depressurization stage unless the makeup coolant level continues to drop. The residual heat removal system can also be coupled in a loop with the refueling water supply tank, for an auxiliary heat removal path.

Corletti, Michael M. (New Kensington, PA); Schulz, Terry L. (Murrysville, PA)

1993-01-01T23:59:59.000Z

488

Combined Systems with Tankless Water Heaters  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Combined Systems with Tankless Water Heaters Combined Systems with Tankless Water Heaters Armin Rudd Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas 2 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas More builder's wanting to use gas-fired tankless water heaters, and with solar pre-heat  Endless hot water  Helps HERS Index  Space saving 2 3 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas Problem with elevated TWH inlet temperature 60 70 80 90 100 110 120 130 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Maximum Inlet Temperature (F) DHW flow rate (gpm) Maximum TWH inlet temperature to stay below 125 F delivered temperature, with 15 kBtu/h minimum firing rate Typical shower temperature 4 Residential Energy Efficiency Stakeholder Meeting

489

Analysis of Energy and Soft Dirt in an Urban Untreated Sewage Source Heat Pump System  

E-Print Network (OSTI)

When using urban untreated sewage as a cool and heat source of heat pump, it is unavoidable to form soft dirt. Based on the method of exergy, an analysis is given of the impact the dirt growth of a tube-shell sewage heat exchanger will have...

Qian, J.; Sun, D.; Li, X.

2006-01-01T23:59:59.000Z

490

Study of Performance of Heat Pump Usage in Sewage Treatment and Fouling Impact on System  

E-Print Network (OSTI)

A heat pump using disposed sewage as a heat source to heat raw sewage is presented to solve the problem that sewage temperature is low in sewage biologic treatment in cold region. According to the status of one medicine factory in Harbin, China...

Song, Y.; Yao, Y.; Ma, Z.; Na, W.

2006-01-01T23:59:59.000Z

491

Miniature thermo-electric cooled cryogenic pump  

SciTech Connect

A miniature thermo-electric cooled cryogenic pump is described for removing residual water molecules from an inlet sample prior to sample analysis in a mass spectroscopy system, such as ion cyclotron resonance (ICR) mass spectroscopy. The cryogenic pump is a battery operated, low power (<1.6 watts) pump with a {Delta}T=100 C characteristic. The pump operates under vacuum pressures of 5{times}10{sup {minus}4} Torr to ultra high vacuum (UHV) conditions in the range of 1{times}10{sup {minus}7} to 3{times}10{sup {minus}9} Torr and will typically remove partial pressure, 2{times}10{sup {minus}7} Torr, residual water vapor. The cryogenic pump basically consists of an inlet flange piece, a copper heat sink with a square internal bore, four two tier Peltier (TEC) chips, a copper low temperature square cross sectional tubulation, an electronic receptacle, and an exit flange piece, with the low temperature tubulation being retained in the heat sink at a bias angle of 5{degree}, and with the TECs being positioned in parallel to each other with a positive potential being applied to the top tier thereof. 2 figs.

Keville, R.F.

1997-11-18T23:59:59.000Z

492

Miniature thermo-electric cooled cryogenic pump  

SciTech Connect

A miniature thermo-electric cooled cryogenic pump for removing residual water molecules from an inlet sample prior to sample analysis in a mass spectroscopy system, such as ion cyclotron resonance (ICR) mass spectroscopy. The cryogenic pump is a battery operated, low power (<1.6 watts) pump with a .DELTA.T=100.degree. C. characteristic. The pump operates under vacuum pressures of 5.times.10.sup.-4 Torr to ultra high vacuum (UHV) conditions in the range of 1.times.10.sup.-7 to 3.times.10.sup.-9 Torr and will typically remove partial pressure, 2.times.10.sup.-7 Torr, residual water vapor. The cryogenic pump basically consists of an inlet flange piece, a copper heat sink with a square internal bore, four two tier Peltier (TEC) chips, a copper low temperature square cross sectional tubulation, an electronic receptacle, and an exit flange piece, with the low temperature tubulation being retained in the heat sink at a bias angle of 5.degree., and with the TECs being positioned in parallel to each other with a positive potential being applied to the top tier thereof.

Keville, Robert F. (Valley Springs, CA)

1997-01-01T23:59:59.000Z

493

Water injected fuel cell system compressor  

DOE Patents (OSTI)

A fuel cell system including a dry compressor for pressurizing air supplied to the cathode side of the fuel cell. An injector sprays a controlled amount of water on to the compressor's rotor(s) to improve the energy efficiency of the compressor. The amount of water sprayed out the rotor(s) is controlled relative to the mass flow rate of air inputted to the compressor.

Siepierski, James S. (Williamsville, NY); Moore, Barbara S. (Victor, NY); Hoch, Martin Monroe (Webster, NY)

2001-01-01T23:59:59.000Z

494

Ground Source Heat Pumps | Open Energy Information  

Open Energy Info (EERE)

Ground Source Heat Pumps Ground Source Heat Pumps (Redirected from Geothermal Heat Pumps) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Ground Source Heat Pumps Geothermal Technologies There are many types of Geothermal Technologies that take advantage of the earth's heat: Hydrothermal Systems Enhanced Geothermal Systems (EGS) Sedimentary Geothermal Systems Co-Produced Geothermal Systems Geothermal Direct Use Ground Source Heat Pumps GSHP Links Related documents and websites An Information Survival Kit for the Prospective Geothemral Heat Pump Owner List of Heat Pumps Incentives List of Ground Source Heat Pumps Incentives Policy Makers' Guidebook for Geothermal Heating and Cooling Various ways to configure a geothermal heat pump system. (Source: The Geo-Heat Center's Survival Kit for the Prospective Geothemral Heat Pump

495

The ABCs of pump selection for mine dewatering  

SciTech Connect

Choosing the right type of pump for removing water from mine operations can provide significant benefits in overall performance and cost of operation. The article describes the types of pump most commonly used: vertical turbine pumps, electric and hydraulic submersible pumps, horizontal multistage centrifugal pumps and horizontal single-stage centrifugal pumps. It gives points to consider when selecting a suitable pump, including solids handling capacity and acid content, portability, automatic operation, easy maintenance and parts availability. 1 photo.

Morgan, S.E.

2008-10-15T23:59:59.000Z

496

Simulating Insulin Infusion Pump Risks by In-Silico Modeling of the Insulin-Glucose Regulatory System.  

E-Print Network (OSTI)

Simulating Insulin Infusion Pump Risks by In-Silico Modeling of the Insulin-Glucose Regulatory for simulating risks due to insulin infusion pump us- age by diabetic patients. Insulin infusion pumps allow-regulate their blood glucose levels. However, the use of infusion pumps and continuous glucose monitors can pose risks

Sankaranarayanan, Sriram

497

Effects of refrigerant charge and structural parameters on the performance of a direct-expansion solar-assisted heat pump system  

Science Journals Connector (OSTI)

Abstract The direct-expansion solar-assisted heat pump (DX-SAHP) is widely studied as a refrigeration system, which can supply hot water for domestic use during the whole year. The system refrigerant charge and structure parameters are believed to have a great effect on the cycling thermal performance. The refrigerant mass charge including two-phase and single-phase in heat exchangers and pipes is calculated with distributed and lumped parameter approach mathematical models, respectively. Based on the system simulation program, the refrigerant distribution characteristics and system performance under varied structural parameters are obtained. The mathematical calculation results show that the 70%–80% refrigerant charge exists in the condenser and collector; the optimum refrigerant charge, solar collector area, condenser pipe length and condenser internal diameter for the system are 1.65–1.75 kg, 6.0 m2, 70 m and 9 mm, respectively. In the optimum parameters, the better system performance and feasible cost can be achieved.

D. Zhang; Q.B. Wu; J.P. Li; X.Q. Kong

2014-01-01T23:59:59.000Z

498

Hot Water Heating System Operation and Energy Conservation  

E-Print Network (OSTI)

Based on an example of the reconstruction of a hot water heating system, this paper provides an analysis and comparison of the operations of hot water heating systems, including supply water temperature adjustment, flow adjustment during each...

Shao, Z.; Chen, H.; Wei, P.

2006-01-01T23:59:59.000Z

499

Seawater pumping as an electricity storage solution for photovoltaic energy systems  

Science Journals Connector (OSTI)

Abstract The stochastic nature of several renewable energy sources has raised the problem of designing and building storage facilities, which can help the electricity grid to sustain larger and larger contribution of renewable energy. Seawater pumped electricity storage is proposed as a good option for PV (Photovoltaic) or solar thermal power plants, located in suitable places close to the coast line. Solar radiation has a natural daily cycle, and storage reservoirs of limited capacity can substantially reduce the load to the electricity grid. Different modes of pump operation (fixed or variable speed) are considered, the preliminary sizing of the PV field and seawater reservoir is performed, and the results are comparatively assessed over a year-long simulated operation. The results show that PV pumped storage, even if not profitable in the present situation of the renewable energy Italian electricity market, is effective in decreasing the load on the transmission grid, and would possibly be attractive in the future, also in the light of developing off-grid applications.

Giampaolo Manfrida; Riccardo Secchi

2014-01-01T23:59:59.000Z

500