Powered by Deep Web Technologies
Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Heat Pump Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Heaters Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales...

2

Selecting a new water heater  

SciTech Connect

This fact sheet describes the types of water heaters available (storage water heaters, demand water heaters, heat pump water heaters, tankless coil and indirect water heaters, and solar water heaters). The criteria for selection are discussed. These are capacity, efficiency rating, and cost. A resource list is provided for further information.

NONE

1995-03-01T23:59:59.000Z

3

Dehumidifying water heater  

SciTech Connect

The indoor swimming pool at the Glen Cove YMCA in Glen Cove, New York, has been selected for the dehumidification/water heating system demonstration project. This report provides the specifications for this system which includes a dehumidifier/air handler, condenser/water heater, and outdoor condenser. Current progress underway includes construction, vendor selection, and control system selection. (SM)

Stark, W.

1991-05-31T23:59:59.000Z

4

Absorption Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

5

Absorption Heat Pump Water Heater  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

6

Heat Pump Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump Water Heaters Heat Pump Water Heaters Standardized Templates for Reporting Test Results heatpumpwaterheaterv1.7.xlsx More Documents & Publications Tankless Gas Water...

7

Do You Have a Solar Water Heater?  

Energy.gov (U.S. Department of Energy (DOE))

Earlier this week, Ernie wrote about theeconomics of getting a solar water heater. As Ernie explained, a solar water heater is more expensive than a normal water heater, but depending on your area...

8

Advanced Hybrid Water Heater using Electrochemical Compressor...  

Energy Savers (EERE)

Advanced Hybrid Water Heater using Electrochemical Compressor Advanced Hybrid Water Heater using Electrochemical Compressor Xergy is using its Electro Chemical Compression (ECC)...

9

Tankless Gas Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Gas Water Heaters Tankless Gas Water Heaters Standardized Templates for Reporting Test Results tanklessgaswaterheaterv12.xlsx More Documents & Publications Heat Pump...

10

Commercial Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heaters Commercial Water Heaters Standardized DOE Testing Templates commercialwaterheater v1.0.xlsx More Documents & Publications Refrigerators and Refrigerator-Freezers...

11

Storage Gas Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storage Gas Water Heaters Storage Gas Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance...

12

Arnold Schwarzenegger WATER HEATERS AND HOT WATER  

E-Print Network (OSTI)

Arnold Schwarzenegger Governor WATER HEATERS AND HOT WATER DISTRIBUTION SYSTEMS;#12;Appendices Appendix A. Multifamily Water Heating Construction Practices, Pricing and Availability Survey Report Appendix B. Multifamily Water Heating Controls Performance Field Report Appendix C. Pipe

13

Heat Pump Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heaters Water Heaters Heat Pump Water Heaters May 4, 2012 - 5:21pm Addthis A diagram of a heat pump water heater. A diagram of a heat pump water heater. What does this mean for me? Heat pump water heaters can be two to three times more energy efficient than conventional electric storage water heaters. Heat pump water heaters work in locations that remain in the 40º-90ºF range year-round. Most homeowners who have heat pumps use them to heat and cool their homes. But a heat pump also can be used to heat water -- either as stand-alone water heating system, or as combination water heating and space conditioning system. How They Work Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. Therefore, they can be two to

14

Tankless Gas Water Heater Performance - Building America Top...  

Energy Savers (EERE)

Tankless Gas Water Heater Performance - Building America Top Innovation Tankless Gas Water Heater Performance - Building America Top Innovation This photo shows a hot water heater...

15

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: Energyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

16

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

2001. Residential Heat Pump Water Heater (HPWH) Development2005. Residential Heat Pump Water Heaters: Energy Efficiencyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

17

Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Ventilation Manufacturing Heat Pumps Appliances & Electronics Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount In-Home Energy Evaluation Program Windows: $500 Duct Repair: $500 Rehabilitation Work: $250 HVAC Replacement: $250/unit HVAC Tune-up: $150/unit Insulation: $500 Water Heater and Pipe Insulation: $50 Air Sealing: $500 Energy Right Program

18

Storage Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storage Water Heaters Storage Water Heaters Storage Water Heaters June 15, 2012 - 6:00pm Addthis Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Conventional storage water heaters remain the most popular type of water heating system for the home. Here you'll find basic information about how storage water heaters work; what criteria to use when selecting the right model; and some installation, maintenance, and safety tips. How They Work A single-family storage water heater offers a ready reservoir -- from 20 to

19

Solar Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Basics Solar Water Heater Basics Solar Water Heater Basics August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel called a flat plate collector is connected to a tank called a solar storage/backup water heater by two pipes. One of these pipes runs through a cylindrical pump into the bottom of the tank, where it becomes a coil called a double-wall heat exchanger. This coil runs up through the tank and out again to the flat plate collector. Antifreeze fluid runs only through this collector loop. Two pipes run out the top of the water heater tank; one is a cold water supply into the tank, and the other sends hot water to the house. Solar water heaters use the sun's heat to provide hot water for a home or

20

Residential Water Heaters Webinar  

Energy.gov (U.S. Department of Energy (DOE))

Jerone Gagliano presents information on water heating technology for U.S Department of Energy Sustainable Energy Resources for Consumers grant program

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Dehumidifying water heater  

SciTech Connect

Drawings and specifications are included for the system to heat water for the swimming pool and dehumidify the building of the Glen Cove YMCA. An overview is presented of the Nautica product used in this system. (MHR)

Not Available

1992-08-18T23:59:59.000Z

22

Electric Storage Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

energy can be wasted even when a hot water tap isn't running. This is called standby heat loss. The American Council for an Energy Efficient Economy provides a helpful...

23

CO2 Heat Pump Water Heater | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heater CO2 Heat Pump Water Heater CO2 Heat Pump Water Heater Prototype
Credit: Oak Ridge National Lab CO2 Heat Pump Water Heater Prototype Credit: Oak Ridge National Lab...

24

Immersible solar water heater  

SciTech Connect

The invention consists in an immersible solar heat collecting means capable of being laid at the bottom of a pool where it can be walked upon. The substantially laminar portions of the collector each includes a surface of higher light absorbence than the other side thereof so that by folding or otherwise overlapping and rearranging the various portions a different number of higher light absorbence surfaces can be presented to the sun to heat the water at any particular time. Such an apparatus makes possible the controlled solar heating of a pool.

Caroon, R.S.

1980-12-09T23:59:59.000Z

25

CO2 Heat Pump Water Heater  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CO 2 Heat Pump Water Heater 2014 Building Technologies Office Peer Review Evaporator Kyle Gluesenkamp, gluesenkampk@ornl.gov Oak Ridge National Laboratory Project Summary Timeline:...

26

Solar Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heaters Solar Water Heaters Solar Water Heaters May 7, 2012 - 9:52am Addthis Solar water heaters -- also called solar domestic hot water systems -- can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they use -- sunshine -- is free. How They Work Solar water heating systems include storage tanks and solar collectors. There are two types of solar water heating systems: active, which have circulating pumps and controls, and passive, which don't. Active Solar Water Heating Systems There are two types of active solar water heating systems: Direct circulation systems Pumps circulate household water through the collectors and into the home. They work well in climates where it rarely freezes. Indirect circulation systems

27

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

heaters heaters Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the flat-plate collector. Solar water heaters use the sun to heat either water

28

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: EnergyA Specification for Residential Heat Pump Water Heaters

Franco, Victor

2011-01-01T23:59:59.000Z

29

Burbank Water and Power - Solar Water Heater Rebate Program (California) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Burbank Water and Power - Solar Water Heater Rebate Program Burbank Water and Power - Solar Water Heater Rebate Program (California) Burbank Water and Power - Solar Water Heater Rebate Program (California) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount $1,500 Provider Rebates Burbank Water and Power is providing incentives for the purchase of solar water heaters. Incentives are only available to residential customers with electric water heaters. There is a limit of one solar water heater per year per property. Applicants must provide access to their residence for a pre-inspection to verify the existing use of an electric water heater. Customers must comply with all code and permit requirements. More

30

Tankless or Demand-Type Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters May 2, 2012 - 6:47pm Addthis Diagram of a tankless water heater. Diagram of a tankless water heater. How does it work? Tankless water heaters deliver hot water as it is needed, eliminating the need for storage tanks. Tankless water heaters, also known as demand-type or instantaneous water heaters, provide hot water only as it is needed. They don't produce the standby energy losses associated with storage water heaters, which can save you money. Here you'll find basic information about how they work, whether a tankless water heater might be right for your home, and what criteria to use when selecting the right model. Check out the Energy Saver 101: Water Heating infographic to learn if a tankless water heater is right for you.

31

Absorption Heat Pump Water Heater - 2013 Peer Review | Department...  

Energy Savers (EERE)

Absorption Heat Pump Water Heater - 2013 Peer Review Absorption Heat Pump Water Heater - 2013 Peer Review Emerging Technologies Project for the 2013 Building Technologies Office's...

32

Residential Absorption Heat Pump Water Heater | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heat Pump Water Heater Residential Absorption Heat Pump Water Heater Photo credit: Oak Ridge National Lab Photo credit: Oak Ridge National Lab Diagram of absorption heat...

33

Ex Parte Memorandum on Grid-Enabled Water Heaters | Department...  

Energy Savers (EERE)

with DOE representatives regarding water heater standards and thermal storage and demand response programs. DOE exparte memo100213 Grid-EnabledWaterHeaterAmendment More...

34

Covered Product Category: Residential Heat Pump Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Heat Pump Water Heaters Covered Product Category: Residential Heat Pump Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance and...

35

Efficient Residential Water Heaters Webinar | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Weatherization Assistance Program Pilot Projects Efficient Residential Water Heaters Webinar Efficient Residential Water Heaters Webinar On Feb. 22, 2011, Jerone Gagliano,...

36

Covered Product Category: Residential Gas Storage Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Storage Water Heaters Covered Product Category: Residential Gas Storage Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for gas storage...

37

Energy Cost Calculator for Electric and Gas Water Heaters | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters Vary equipment size, energy cost, hours of operation, and or efficiency level. INPUT...

38

Tankless Water Heaters: Do They Really Work?  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Water Heaters: Do They Tankless Water Heaters: Do They Really Work? Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer Context * Domestic Water Heating is the next big residential energy in efficiency. - Space heating loads are being reduced - Largest peak load in almost all homes is water heating - Annual water heating load is larger than annual space heating load in many homes - Most DHW equipment is inefficiency 50-60% Technical Approach * TWHs and condensing TWHs have significant energy savings potential - Do these ratings relate to real world performance? - How do TWHs compare to standard water heaters? - What performance/install issues do they have? * 10 home 26 water heater alternating mode field study was conducted Recommended Guidance * In situations where economics are

39

DOE Publishes Notice of Proposed Rulemaking for Residential Water Heater and Certain Commercial Water Heater Test Procedures  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy has published a notice of proposed rulemaking regarding test procedures for residential water heaters and certain commercial water heaters.

40

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

water heaters water heaters (Redirected from - Solar Hot Water) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Sizing a New Water Heater | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sizing a New Water Heater Sizing a New Water Heater Sizing a New Water Heater May 29, 2012 - 7:16pm Addthis Is your water heater the right size for you house? | Photo credit ENERGY STAR® Is your water heater the right size for you house? | Photo credit ENERGY STAR® A properly sized water heater will meet your household's hot water needs while operating more efficiently. Therefore, before purchasing a water heater, make sure it's the correct size. Here you'll find information about how to size these systems: Tankless or demand-type water heaters Solar water heating system Storage and heat pump (with tank) water heaters. For sizing combination water and space heating systems -- including some heat pump systems, and tankless coil and indirect water heaters -- consult a qualified contractor.

42

Selecting a New Water Heater | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Selecting a New Water Heater Selecting a New Water Heater Selecting a New Water Heater August 29, 2012 - 7:30pm Addthis Water heater testing facility at Oak Ridge National Laboratory. Water heater testing facility at Oak Ridge National Laboratory. When selecting a new water heater for your home, choose a water heating system that will not only provide enough hot water but also that will do so energy efficiently, saving you money. This includes considering the different types of water heaters available and determining the right size and fuel source for your home. Check out the Energy Saver 101: Water Heating infographic to learn more about the different types of water heaters and how to select the right model for your home. Types of Water Heaters It's a good idea to know the different types of water heaters available

43

Heat Pump Water Heaters Demonstration Project  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heat Pump Water Heaters Heat Pump Water Heaters Demonstration Project Building America Stakeholder Meeting Ron Domitrovic Ammi Amarnath 3/1/2012 Austin, TX 2 © 2011 Electric Power Research Institute, Inc. All rights reserved. HPWH Field Demonstration: Research Objectives * Assess heat pump water heater technology by measuring efficiency. * Provide credible data on the performance and reliability of heat pump water heaters. * Assess user satisfaction in a residential setting. 3 © 2011 Electric Power Research Institute, Inc. All rights reserved. Demonstration Host Utilities Target: 40 Units per Utility Installed and Potential Sites by Climate Zone Source: Department of Energy (DOE), Building America climate regions 4 © 2011 Electric Power Research Institute, Inc. All rights reserved. Installation Locations-Southern Company Region

44

Tankless Coil and Indirect Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters May 16, 2013 - 7:21pm Addthis An indirect water heater. An indirect water heater. How does it work? Tankless coil and indirect water heaters use your home's heating system to heat water. Tankless coil and indirect water heaters use a home's space heating system to heat water. They're part of what's called integrated or combination water and space heating systems. How They Work A tankless coil water heater provides hot water on demand without a tank. When a hot water faucet is turned on, water is heated as it flows through a heating coil or heat exchanger installed in a main furnace or boiler. Tankless coil water heaters are most efficient during cold months when the heating system is used regularly but can be an inefficient choice for many

45

Solar Water Heater Rebate | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Rebate Solar Water Heater Rebate Solar Water Heater Rebate < Back Eligibility Commercial Fed. Government Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Hawaii Program Type State Rebate Program Rebate Amount Residential Solar Water Heating: $1,000 upfront, or Residential Solar Water Heating Interest Loan Buy-Down: $1,000 Residential Solar Attic Fans: $50 Commercial: $250 per 12,000 Btu/hr derated capacity Provider Hawaii Energy Hawaii Energy, a third-party administered public benefits fund, provides incentives for energy efficiency and conservation to customers of the Hawaiian Electric Company (HECO) and its subsidiaries, Maui Electric Company (MECO) and Hawaii Electric Light Company (HELCO). This incentive is available for installations on the islands of Oahu, Hawaii, Maui, Lanai and

46

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network (OSTI)

Diagram 1: A Typical Tank Water Heater Source: http://to-unit comparisons of tank versus tankless water heaters.Energy Use MJ/(unit*year) Tank Tankless MJ/(unit*year) Tank

Lu, Alison

2011-01-01T23:59:59.000Z

47

Tankless Coil and Indirect Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Coil and Indirect Water Heater Basics Coil and Indirect Water Heater Basics Tankless Coil and Indirect Water Heater Basics August 19, 2013 - 3:03pm Addthis Illustration of a tankless coil water heater. The heater is box-shaped, and has two pipes sticking out one end: one a cold water inlet, and one a hot water outlet. These pipes lead into the heater to a cylindrical coil called a heat exchanger. Long tubes surrounding the heat exchanger are labeled the heated water jacket. At the bottom of the box is a row of small flames, called the boiler heat source. Tankless coil and indirect water heaters use a home or building's space heating system to heat water as part of an integrated or combination water and space heating system. How Tankless Coil and Indirect Water Heaters Work A tankless coil water heater uses a heating coil or heat exchanger

48

Combined Systems with Tankless Water Heaters  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Combined Systems with Tankless Water Heaters Combined Systems with Tankless Water Heaters Armin Rudd Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas 2 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas More builder's wanting to use gas-fired tankless water heaters, and with solar pre-heat  Endless hot water  Helps HERS Index  Space saving 2 3 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas Problem with elevated TWH inlet temperature 60 70 80 90 100 110 120 130 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Maximum Inlet Temperature (F) DHW flow rate (gpm) Maximum TWH inlet temperature to stay below 125 F delivered temperature, with 15 kBtu/h minimum firing rate Typical shower temperature 4 Residential Energy Efficiency Stakeholder Meeting

49

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

E-Print Network (OSTI)

Survey of Electric Storage Tank Water Heater Efficiency andSurvey of Electric Storage Tank Water Heater Efficiency andby electric resistance storage tank water heaters (geysers),

Johnson, Alissa

2013-01-01T23:59:59.000Z

50

Covered Product Category: Commercial Gas Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including commercial gas water heaters, which are covered by the ENERGY STAR program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

51

Building Technologies Office: HVAC and Water Heater Field Tests Research  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

52

Heat Pump Water Heater using Solid-State Energy Converters |...  

Energy Savers (EERE)

Heat Pump Water Heater using Solid-State Energy Converters Heat Pump Water Heater using Solid-State Energy Converters Sheetak will work on developing a full scale prototype of its...

53

TVA Partner Utilities- Energy Right Water Heater Program  

Energy.gov (U.S. Department of Energy (DOE))

The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each...

54

TVA Partner Utilities- Energy Right Water Heater Program  

Energy.gov (U.S. Department of Energy (DOE))

The Tennessee Valley Authority (TVA) energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local...

55

Making Water Heaters More Efficient | GE Global Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Heaters More Efficient Making Water Heaters More Efficient Jigar Shah 2013.11.13 As children, many of us grow up wanting to make some sort of lasting positive impact on...

56

NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet)  

SciTech Connect

NREL evaluates energy savings potential of heat pump water heaters in homes throughout all U.S. climate zones.

Not Available

2012-02-01T23:59:59.000Z

57

AWSWAH - the heat pipe solar water heater  

SciTech Connect

An all weather heat pipe solar water heater (AWSWAH) comprising a collector of 4 m/sup 2/ (43 ft/sup 2/) and a low profile water tank of 160 liters (42 gal.) was developed. A single heat pipe consisting of 30 risers and two manifolds in the evaporator and a spiral condenser was incorporated into the AWSWAH. Condensate metering was done by synthetic fiber wicks. The AWSWAH was tested alongside two conventional solar water heaters of identical dimensions, an open loop system and a closed loop system. It was found that the AWSWAH was an average of 50% more effective than the open system in the temperature range 30-90 /sup 0/C (86-194 /sup 0/F). The closed loop system was the least efficient of the three systems.

Akyurt, M.

1986-01-01T23:59:59.000Z

58

TVA Partner Utilities - Energy Right' Water Heater Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Right' Water Heater Program Right&#039; Water Heater Program TVA Partner Utilities - Energy Right' Water Heater Program < Back Eligibility Installer/Contractor Residential Utility Savings Category Appliances & Electronics Water Heating Maximum Rebate Member utility water heater rebate programs can range from $25 to total cost. Program Info State Mississippi Program Type Utility Rebate Program Rebate Amount Energy Efficient Water Heater: $50 from TVA Provider Tennessee Valley Authority The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each installation. Power Companies may pass these incentives on to customers. Customers should contact their local power company to see what programs are

59

Condensing Hybrid Water Heater Monitoring Field Evaluation  

NLE Websites -- All DOE Office Websites (Extended Search)

Condensing Hybrid Water Heater Condensing Hybrid Water Heater Monitoring Field Evaluation Jeff Maguire, Lieko Earle, and Chuck Booten National Renewable Energy Laboratory C.E. Hancock Mountain Energy Partnership Produced under direction of the Sacramento Municipal Utilities District by the National Renewable Energy Laboratory (NREL) under Interagency Agreement CRD-05-168 and Task No WR49.3000. Technical Report NREL/TP-5500-52234 October 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308

60

An Overview of the New Residential Water Heater Efficiency Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

An Overview of the New Residential Water Heater Efficiency Standards An Overview of the New Residential Water Heater Efficiency Standards Speaker(s): Alex Lekov Date: April 26, 2010 - 12:00pm Location: 90-3122 DOE issued new standards for residential water heaters last month that will save an estimated 2.6 quads of energy over 30 years. For most product sizes sold, the new standards can be met with modest changes, such as adding more insulation to today's conventional tank-style water heaters. For the most common size electric water heater (50 gallons), the standards will save 4 percent, while for the most common size gas water heater (40 gallons), the new standards will save 3 percent. However, for the biggest products (those with over 55 gallons in storage capacity, which is about 9% and 4% of the electric and gas storage water heater markets, respectively), the new

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Carbon Dioxide Heat Pump Water Heater Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Research Project Carbon Dioxide Heat Pump Water Heater Research Project The U.S. Department of Energy is currently conducting research into carbon dioxide (CO2) heat pump water heaters. This project will employ innovative techniques to adapt water heating technology to meet U.S. market requirements, including specifications, cost, and performance targets. Carbon dioxide is a refrigerant with a global warming potential (GWP) of 1. The CO2 heat pump water heater research seeks to develop an improved life cycle climate performance compared to conventional refrigerants. For example, R134a, another type of refrigerant, has a GWP of 1,300. Project Description This project seeks to develop a CO2-based heat pump water heater (HPWH)

62

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Free high efficiency water Heater; $200 installation fee Water heater and timer with normal installation: $2.50 credit for 10 years Timer only: $200 cash payment and $2.50 credit for 10 years New construction contract home: $250 Provider Aiken Electric Cooperative Aiken Electric Cooperative offers residential members rebates for installing high-efficiency electric water heaters and/or timers in their homes. Customers have four rebate options:

63

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount Existing Homes Solar Water Heater: $750 New Homes Solar Water Heater: $1,250 - $1,500 Provider Coweta-Fayette Electric Membership Corporation Coweta-Fayette Electric Membership Corporation (EMC) provides electric and natural gas service to 58,000 customers in Georgia's Coweta, Fayette, Meriwether, Heard, Troop and Fulton counties. Currently, Coweta-Fayette EMC offers rebates on solar water heaters from $750 up to $1,500 as part of the Touchstone Energy Home Program. Solar

64

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program < Back Eligibility Agricultural Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Iowa Program Type Utility Rebate Program Rebate Amount $500 Provider Linn County Rural Electric Cooperative Association Linn County Rural Electric Cooperative Association (Linn County RECA) is a member-owned cooperative. To encourage energy efficiency, Linn County offers a number of rebates to commercial, residential, and agricultural customers. Owners of both new construction and existing buildings are eligible for a $500 rebate for solar water heaters. The water heaters must have an auxiliary tank of at least 40 gallons and the solar water heater

65

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Water Heater: up to $275 Heat Pump Replacement: $400 Provider Rock Hill Utilities Through the SmartChoice program, Rock Hill Utilities offers rebates for water heater and heat pump replacements. Information on financing for heat pumps can also be found on the web site listed above. If both the water heater and heat pump are purchased then the customer may qualify for the Great Rate program. The Great Rate program will add a 25% discount to a

66

Tankless Demand Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Demand Water Heater Basics Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

67

Tankless Demand Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

68

The Trials and Tribulations of Testing Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

The Trials and Tribulations of Testing Water Heaters The Trials and Tribulations of Testing Water Heaters Speaker(s): James Lutz Date: August 14, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn During our work on efficiency standards for electric water heaters, we discovered significant discrepancies between the rated and tested efficiencies of the highest rated electric resistance water heaters. For high efficiency electric resistance water heaters with an Energy Factor above .92, the heat losses are so small that minor flaws in the tank or obscure problems in the test procedure become more apparent. This seminar reports on our investigation into the causes of inconsistent results obtained during testing of high efficiency electric resistance water heaters at different test labs. We discovered some reasons for the

69

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet)  

SciTech Connect

A new simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes.

Hudon, K.

2012-05-01T23:59:59.000Z

70

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

as conventional electric resistance water heaters, with thetwo technologies: (1) an electric resistance storage watertransfers heat from the electric resistance element to the

Franco, Victor

2011-01-01T23:59:59.000Z

71

Clark Public Utilities - Solar Water Heater Rebate | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate < Back Eligibility Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $500 Provider Clark PUD Clark Public Utilities offers a rebate of $500 to customers who install a solar water heating system. Customers must own the residence or business where the solar water heating system is installed and must have an electric water heater. In addition, Clark Public Utilities offers a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA29F&re=1&ee=1 loan program] for eligible solar water heater equipment. For additional information, call Energy Services at (360) 992-3355.

72

Heat Pump Water Heater Performance in  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

searc searc e er tra A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida searc e er tra Heat Pump Water Heater Performance in Laboratory House Building America Technical Update 2013 ACI National Home Performance Conference April 29- 30 , 2013 Carlos J. Colon carlos@fsec.ucf.edu A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida Hot Water Systems (HWS) Laboratory FSEC Grounds, Florida (east coast) 2009 -Present (Currently fourth testing rotation) FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida

73

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate $600 Program Info State Florida Program Type Utility Rebate Program Rebate Amount 0.01 per BTU output Provider Clay Electric Co-op Clay Electric Cooperative (CEC) provides a rebate of $0.01 per BTU output to its residential members when they purchase qualified solar water heaters. This rebate is capped at 60,000 BTUs per system, or $600. Eligible solar water heaters can be either passive or active systems. The proposed solar system must meet Florida Solar Energy Center (FSEC) specifications and be installed by a contractor certified to install solar water heating

74

Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tri-County Electric Cooperative - Energy Efficient Water Heater Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program < Back Eligibility Commercial Residential Savings Category Appliances & Electronics Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $75 Provider Tri-County Electric Cooperative Tri-County Electric Cooperative offers a $75 rebate on the purchase of energy-efficient electric water heaters. The rebate is valid for new or replacement units which have an Energy Factor Rating of 0.90 or higher. The minimum tank size is 40 gallons, with a minimum 4,500 watt heating element. For validation purposes, a copy of the sales or installation receipt must accompany the [http://www.tcectexas.com/Forms/water%20heater%20rebate%20form.pdf

75

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

Building Energy Efficiency Standards .. 4 Multi-Family Water Heating.. 4 Pipe HeatBuilding Energy Efficiency Standards The scope of this task included the following subtasks; Multi-Family Water Heating, Pipe Heat

Lutz, Jim

2012-01-01T23:59:59.000Z

76

Cost of Increased Energy Efficiency for Residential Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Cost of Increased Energy Efficiency for Residential Water Heaters Cost of Increased Energy Efficiency for Residential Water Heaters Speaker(s): Alex Lekov Date: March 22, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn This presentation describes the analysis of the costs of increased energy efficiency for residential water heaters. Here, we focus on the cost and efficiency data for electric and gas-fired water heaters. This data formed the basis of the Technical Support Document for the Department of Energy's (DOE) Final Rule on Water Heaters. The engineering analysis uses computer simulation models to investigate the efficiency improvements due to design options and combinations thereof. The analysis covers four polyurethane foam insulation types based on non-ozone-depleting substances as blowing

77

FS: heat pump water heaters | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Food Service » Install a heat pump Food Service » Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specificat Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specification The Food Service team developed a Commercial Heat Pump Water Heater Specification that can be used to reduce water heating energy by 70%. An older, electric resistance water heater (operated in a building with a hot water demand of 500 gallons a day) can cost more than $3,500 each year

78

Georgia Power- Residential Solar and Heat Pump Water Heater Rebate (Georgia)  

Energy.gov (U.S. Department of Energy (DOE))

Georgia Power customers may be eligible for rebates up to $250 each toward the installation costs of a 50 gallon or greater solar water heater or heat pump water heater. The solar water heater or...

79

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

SciTech Connect

Residential water heating is a large source of energy use in California homes. This project took a life cycle approach to comparing tank and tankless water heaters in Northern and Southern California. Information about the life cycle phases was calculated using the European Union?s Methodology study for EcoDesign of Energy-using Products (MEEUP) and the National Renewable Energy Laboratory?s Life Cycle Inventory (NREL LCI) database. In a unit-to-unit comparison, it was found that tankless water heaters would lessen impacts of water heating by reducing annual energy use by 2800 MJ/year (16% compared to tank), and reducing global warming emissions by 175 kg CO2 eqv./year (18% reduction). Overall, the production and combustion of natural gas in the use phase had the largest impact. Total waste, VOCs, PAHs, particulate matter, and heavy-metals-to-air categories were also affected relatively strongly by manufacturing processes. It was estimated that tankless water heater users would have to use 10 more gallons of hot water a day (an increased usage of approximately 20%) to have the same impact as tank water heaters. The project results suggest that if a higher percentage of Californians used tankless water heaters, environmental impacts caused by water heating would be smaller.

Lu, Alison; McMahon, James; Masanet, Eric; Lutz, Jim

2008-08-13T23:59:59.000Z

80

Utilization of Heat Pump Water Heaters for Load Management  

SciTech Connect

The Energy Conservation Standards for Residential Water Heaters require residential electric storage water heaters with volumes larger than 55 gallons to have an energy factor greater than 2.0 after April 2015. While this standard will significantly increase the energy efficiency of water heaters, large electric storage water heaters that do not use heat pump technologies may no longer be available. Since utilities utilize conventional large-volume electric storage water heaters for thermal storage in demand response programs, there is a concern that the amended standard will significantly limit demand response capacity. To this end, Oak Ridge National Laboratory partnered with the Tennessee Valley Authority to investigate the load management capability of heat pump water heaters that meet or exceed the forthcoming water heater standard. Energy consumption reduction during peak periods was successfully demonstrated, while still meeting other performance criteria. However, to minimize energy consumption, it is important to design load management strategies that consider the home s hourly hot water demand so that the homeowner has sufficient hot water.

Boudreaux, Philip R [ORNL; Jackson, Roderick K [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Lyne, Christopher T [ORNL

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Solar Water Heater Roadmap Leads Path to Market Expansion (Fact Sheet)  

SciTech Connect

Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace.

Not Available

2012-09-01T23:59:59.000Z

82

Evaluation of TANK water heater simulation model as embedded in HWSim  

E-Print Network (OSTI)

this scheme for operating TANK with HWSim is successful.LBNL # Evaluation of TANK water heater simulation model asCalifornia. Evaluation of TANK water heater simulation model

Lutz, Jim

2012-01-01T23:59:59.000Z

83

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network (OSTI)

Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and PoolConservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating Equipment, and Pool

Lutz, Jim

2012-01-01T23:59:59.000Z

84

New Braunfels Utilities - Residential Solar Water Heater Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Braunfels Utilities - Residential Solar Water Heater Rebate New Braunfels Utilities - Residential Solar Water Heater Rebate Program New Braunfels Utilities - Residential Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $0.265/kWh Provider New Braunfels Utilities New Braunfels Utilities offers a rebate for residential customers who purchase and install solar water heating systems on eligible homes. A rebate of the equivalent of $0.265 per kWh is available to these customers. The maximum rebate amount is $900 for participating customers. Applicants must have an active residential electric service account with NBU in order to be eligible. Solar water heaters must preheat water for an electric

85

The Impact of Blowing Agents on Residential Water Heater Performance  

NLE Websites -- All DOE Office Websites (Extended Search)

The Impact of Blowing Agents on Residential Water Heater Performance The Impact of Blowing Agents on Residential Water Heater Performance Title The Impact of Blowing Agents on Residential Water Heater Performance Publication Type Report LBNL Report Number LBNL-47352 Year of Publication 2001 Authors Lekov, Alexander B., James D. Lutz, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-47352 Date Published January 12 Abstract The National Appliance Energy Conservation Act of 1987 (NAECA) requires the U.S. Department of Energy (DOE) to consider amendments to the energy conservation standards to increase energy efficiency in residential water heaters. A driving force affecting efficiency is the ozone-depletion regulation regarding blowing agents for insulation in all water heater fuel types. This paper presents results of cost and efficiency impacts of three potential blowing agents. Residential water heaters are typically insulated with polyurethane foam in the space between the tank and the jacket. Currently, water heater manufacturers use HCFC-141b, an ozone-depleting substance, as a blowing agent. After 2003, as a result of the Montreal Protocol (1993), manufacturers must use blowing agents that do not deplete the ozone layer. The analysis presented in this paper considers three replacement candidates, HFC-245fa, HFC-134a, and cyclopentane by comparing their efficiency and cost effectiveness when applied to water heater insulation. This analysis used computer simulation models and other analytical methods to investigate the efficiency improvements due to different design options, when alternative blowing agents are applied. The calculations were based on the DOE test procedure for residential water heaters. The analysis used average manufacturer, retailer, and installer costs to calculate the total consumer costs. Consumer operating expenses were calculated based on modeled energy consumption under test procedure conditions and U.S. average energy prices. With this information, a cost-efficiency relationship was developed to show the average manufacturer and consumer cost to achieve increased efficiency.

86

Grays Harbor PUD - Solar Water Heater Rebate | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate < Back Eligibility Commercial Industrial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $600 Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a rebate program for the installation of solar water heaters. Rebates of $600 are available for the installation of solar collectors of 40 square feet or more. Only customers who currently use electricity for hot water are eligible. This rebate is available on a case-by-case basis, so you must contact the utility in order to take advantage of it. Customers may choose a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA09F&re=1&ee=1

87

Grays Harbor PUD - Solar Water Heater Loan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Loan Solar Water Heater Loan Grays Harbor PUD - Solar Water Heater Loan < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate not specified Program Info State District of Columbia Program Type Utility Loan Program Rebate Amount not specified Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a low-interest loan program (currently 4.0%) for the installation of solar water heaters. Loans are available for the installation of solar collectors of 40 square feet or more. The loans are provided through local lenders, with interest subsidized by the PUD. Only customers who currently use electricity for hot water are eligible. Pre-approval is required for this loan and loan amounts are determined on a case-by-case basis.

88

Solar Water Heaters and the Economy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heaters and the Economy Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a warm and sudsy campsite clean-up is possible.

89

Solar Water Heaters and the Economy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heaters and the Economy Solar Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a

90

Covered Product Category: Gas Storage Water Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Gas Storage Water Heaters Gas Storage Water Heaters Covered Product Category: Gas Storage Water Heaters October 7, 2013 - 10:43am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

91

Split system CO2 heat pump water heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Split-system-CO2-heat-pump-water-heaters- Sign In About | Careers | Contact | Investors | bpa.gov Search Policy & Reporting Expand Policy & Reporting EE Sectors Expand EE...

92

Monitoring SERC Technologies: On-Demand Tankless Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

A webinar by Ethan MacCormick, VP for Services to Energy Businesses at Performance Systems Development, about On-Demand Tankless Water Heaters and how to properly monitor the installation.

93

New Home Buyer Solar Water Heater Trade-Off Study  

SciTech Connect

This report details the results of a research conducted in 1998 and 1999 and outlines a marketing deployment plan designed for businesses interested in marketing solar water heaters in the new home industry.

Symmetrics Marketing Corporation

1999-08-18T23:59:59.000Z

94

Marshall Municipal Utilities- Solar Thermal Water Heater Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Marshall Municipal Utilities (MMU) offers residential customers rebates for installing a ENERGY STAR Solar Thermal Water Heater. Rebates are based on the size of the system; MMU offers $20 per...

95

Savings Project: Insulate Your Water Heater Tank | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Addthis Project Level medium Energy Savings $20-$45 annually Time to Complete 1.5 hours Overall Cost $30 Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Just like insulating your walls or roof, insulating your hot water tank is an easy and inexpensive way to improve energy efficiency and save you money each month. If your water tank is new, it is likely already insulated. If you have an older hot water tank, check to see if it has insulation with an R-value of at least 24. If not, consider insulating your water tank, which

96

Determining Benefits and Costs of Improved Water Heater Efficiencies  

NLE Websites -- All DOE Office Websites (Extended Search)

Determining Benefits and Costs of Improved Water Heater Efficiencies Determining Benefits and Costs of Improved Water Heater Efficiencies Title Determining Benefits and Costs of Improved Water Heater Efficiencies Publication Type Report LBNL Report Number LBNL-45618 Year of Publication 2000 Authors Lekov, Alexander B., James D. Lutz, Xiaomin Liu, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-45618 Date Published May 4 Abstract Economic impacts on individual consumers from possible revisions to U.S. residential water heater energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a water heater and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers are significant. At the efficiency level examined in this paper, 35% of households with electric water heaters experience LCC savings, with an average savings of $106, while 4% show LCC losses, with an average loss of $40 compared to a pre-standard LCC average of $2,565. The remainder of the population (61%) are largely unaffected.

97

THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER  

E-Print Network (OSTI)

#12;THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER Laboratory testing and field testing have shown that a heat pump water heater (HPWH) uses about half the electrical energy input that an electric resistance water heater does. However, since the heat pump water heater

Oak Ridge National Laboratory

98

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

99

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

100

SMUD - Solar Water Heater Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Water Heater Rebate Program Solar Water Heater Rebate Program SMUD - Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount 500 - 1,500 per system, depending on energy savings Provider Sacramento Municipal Utility District The Sacramento Municipal Utility District's (SMUD) Solar Domestic Hot Water Program provides rebates and/or loan financing to customers who install solar water heating systems. The amount of the rebate depends on how much electricity the system will offset annually: * 800 - 1,399 kWh: $500 * 1,400 - 2,199 kWh: $1,000 * 2,200 kWh or greater: $1,500 . All solar water-heating units must meet standards set by the Solar Rating

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

List of Water Heaters Incentives | Open Energy Information  

Open Energy Info (EERE)

Heaters Incentives Heaters Incentives Jump to: navigation, search The following contains the list of 973 Water Heaters Incentives. CSV (rows 1-500) CSV (rows 501-973) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes AEP Public Service Company of Oklahoma - Residential Efficiency Rebate Program (Oklahoma) Utility Rebate Program Oklahoma Residential Building Insulation

102

A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.  

E-Print Network (OSTI)

??Heat pump water heaters are a promising technology to reduce energy use and greenhouse gas emissions. A key component is the water heating heat exchanger. (more)

Weerawoot, Arunwattana

2010-01-01T23:59:59.000Z

103

Outdoor Outfitter Gets Greener With Solar Water Heater | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater October 8, 2010 - 12:51pm Addthis L.L. Bean’s flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | L.L. Bean's flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | Lindsay Gsell L.L. Bean is known for its outdoor apparel- jackets, backpacks and cozy winter sweaters. However, the company does more than just dress for the outdoors, it also works to protect and preserve it. For nearly 100 years, L.L. Bean has been committed to environmental conservation and

104

Heat Pump Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heater Basics Water Heater Basics Heat Pump Water Heater Basics August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a larger one on the bottom. In the top chamber are a fan, a cylindrical compressor, and an evaporator that runs along the inside of the chamber. Jutting out from the exterior of the bottom chamber is a temperature and pressure relief valve. This valve has a tube called a hot water outlet attached to the top. Below the valve is the upper thermostat, a small square outside the cylinder that is attached to a curved tube inside the heater. Resistance elements run from the upper thermostat to the similarly shaped lower thermostat. Below the lower thermostat is a drain valve with a cold water inlet attached to the top. Inside the cylinder is an anode, a series of thin tubes running through the bottom chamber to a coiled tube called a condenser. Insulation runs along the inside of the cylinder.

105

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

FEMP Designated Product Assessment for Commercial Gas Water Heaters FEMP Designated Product Assessment for Commercial Gas Water Heaters Title FEMP Designated Product Assessment for Commercial Gas Water Heaters Publication Type Report LBNL Report Number LBNL-5514E Year of Publication 2010 Authors Lutz, James D. Subsidiary Authors Energy Analysis Department Document Number LBNL-5514E Pagination 8 Date Published April 1 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5514E Abstract None Notes This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. Attachment Size PDF 240.22 KB Google Scholar BibTex RIS RTF XML Alternate URL: http://eetd.lbl.gov/node/50317

106

Experimental study of integrated collector storage solar water heaters  

Science Journals Connector (OSTI)

Three Integrated Collector Storage Solar Water Heaters (ICSSWH) have been designed, constructed and experimentally studied in comparison to a Flat Plate Thermosiphonic Unit (FPTU). Each of the ICS experimental models consists of one cylindrical tank horizontally mounted in a stationary symmetrical Compound Parabolic Concentrating (CPC) reflector trough. The main objective is the design and construction of low cost solar water heaters with improved thermal performance and lower possible depths. The experimental models can be mounted on horizontal as well as on inclined roofs by adopting the lowest possible depth. The results show that these solar devices perform more than effectively all year long. This could contribute significantly on the development of ICS type solar water heaters.

M. Souliotis; D. Chemisana; Y.G. Caouris; Y. Tripanagnostopoulos

2013-01-01T23:59:59.000Z

107

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect

This report discusses how a significant opportunity for energy savings is domestic hot water heating, where an emerging technology has recently arrived in the U.S. market: the residential integrated heat pump water heater. A laboratory evaluation is presented of the five integrated HPWHs available in the U.S. today.

Sparn, B.; Hudon, K.; Christensen, D.

2011-09-01T23:59:59.000Z

108

Conventional Storage Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On top of the tank are two thin pipes; one pipe is the hot water outlet, and the other is the cold water inlet. A large pipe in the middle is called a vent pipe. A pressure/temperature relief valve is also on top of the tank and is connected to an open pipe that runs down the side of the tank. Another valve near the bottom of the outside of the tank is the thermostat and gas valve. A cutout shows the parts inside the tank, which include a large tube called a flue tube/heat exchanger. Inside this tube is a jagged insert called a flue baffle. Beside the flue tube/heat exchanger is a thin tube called the anode rod. At the bottom of the tank is a gas burner, and beneath the burner are combustion air openings.

109

Development of a Market Optimized Condensing Gas Water Heater  

SciTech Connect

This program covered the development of a market optimized condensing gas water heater for residential applications. The intent of the program was to develop a condensing design that minimized the large initial cost premium associated with traditional condensing water heater designs. Equally important was that the considered approach utilizes design and construction methods that deliver the desired efficiency without compromising product reliability. Standard condensing water heater approaches in the marketplace utilize high cost materials such as stainless steel tanks and heat exchangers as well as expensive burner systems to achieve the higher efficiencies. The key in this program was to develop a water heater design that uses low-cost, available components and technologies to achieve higher efficiency at a modest cost premium. By doing this, the design can reduce the payback to a more reasonable length, increasing the appeal of the product to the marketplace. Condensing water heaters have been in existence for years, but have not been able to significantly penetrate the market. The issue has typically been cost. The high purchase price associated with existing condensing water heaters, sometimes as much as $2000, has been a very difficult hurdle to overcome in the marketplace. The design developed under this program has the potential to reduce the purchase price of this condensing design by as much as $1000 as compared to traditional condensing units. The condensing water heater design developed over the course of this program led to an approach that delivered the following performance attributes: 90%+ thermal efficiency; 76,000 Btu/hr input rate in a 50 gallon tank; First hour rating greater than 180 gph; Rapid recovery time; and Overall operating condition well matched to combination heat and hot water applications. Over the final three years of the program, TIAX worked very closely with A.O. Smith Water Products Company as our commercial partner to optimize the design for manufacturing. This work included the initiation of a large field testing program (over 125 units) and an in-depth reliability program intended to minimize the risks associated with a new product introduction. At the time of this report, A.O. Smith plans to introduce this product to the marketplace in the early 2006 time period.

Peter Pescatore

2006-01-11T23:59:59.000Z

110

Covered Product Category: Residential Heat Pump Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including residential heat pump water heaters, which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

111

Covered Product Category: Residential Electric Resistance Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

FEMP sets Federal efficiency requirements and provides acquisition guidance across a variety of product categories, including residential electric resistance water heaters. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

112

Applications Tests of Commercial Heat Pump Water Heaters  

E-Print Network (OSTI)

Field application tests have been conducted on three 4 to 6-ton commercial heat pump water heater systems in a restaurant, a coin-operated laundry, and an office building cafeteria in Atlanta. The units provide space cooling while rejecting heat...

Oshinski, J. N..; Abrams, D. W.

1987-01-01T23:59:59.000Z

113

Covered Product Category: Residential Gas Storage Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

114

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers (EERE)

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

115

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

Sparn, B.; Hudon, K.; Christensen, D.

2014-06-01T23:59:59.000Z

116

Modeling and Test-and-Rate Methods for Innovative Thermosiphon Solar Water Heaters: Preprint  

SciTech Connect

Conference paper regarding research in modeling and test-and-rate methods for thermosiphon solar domestic water heaters.

Burch, J.; Shoukas, G.; Brandemuhl, M.; Krarti, M.

2006-05-01T23:59:59.000Z

117

Field Testing of Pre-Production Prototype Residential Heat Pump Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Provides and overview of field testing of 18 pre-production prototype residential heat pump water heaters

118

Assessment of Unglazed Solar Domestic Water Heaters  

SciTech Connect

Conference paper investigating cost-performance tradeoffs in replacing glazed collectors with unglazed collectors in solar domestic water heating systems.

Burch, J.; Salasovich, J.; Hillman, T.

2005-12-01T23:59:59.000Z

119

Placing technology : examining the emerging use of solar water heaters in Oaxaca, Mexico: Examining the emerging use of solar water heaters in Oaxaca, Mexico.  

E-Print Network (OSTI)

??This study is an examination of the (broadly envisioned) process that has led to the emerging use of solar water heaters in Oaxaca de Jua?rez, (more)

Shannon, Steven Jacob

2011-01-01T23:59:59.000Z

120

Salem Electric- Solar Water Heater Rebate  

Energy.gov (U.S. Department of Energy (DOE))

Salem Electric residential customers with electric water heating are eligible for a $600 rebate through Salem's Bright Way program. A program brochure with details is available on the program...

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Dehumidifying water heater. Technical progress report  

SciTech Connect

Drawings and specifications are included for the system to heat water for the swimming pool and dehumidify the building of the Glen Cove YMCA. An overview is presented of the Nautica product used in this system. (MHR)

Not Available

1992-08-18T23:59:59.000Z

122

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

Performance Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Technical Report NREL/TP-5500-52635 September 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Prepared under Task Nos. WTN9.1000, ARRB.2204 Technical Report NREL/TP-5500-52635 September 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government.

123

Selecting a New Water Heater You have a lot to consider when selecting a  

E-Print Network (OSTI)

the water heater's annual operation costs but also its size and energy efficiency. Natural gas, oil or tank water heater operates by releasing hot water from the top of the tank when the hot water tap is turned on. The hot water is released into the hot water line. As the hot water leaves the tank, cold

124

Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Carbon Dioxide-Based Carbon Dioxide-Based Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on AddThis.com...

125

Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater  

NLE Websites -- All DOE Office Websites (Extended Search)

Gas-Fired Absorption Gas-Fired Absorption Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on AddThis.com...

126

Inherent freeze protection for solar water heaters  

SciTech Connect

Research and development of a method for protection of a solar collector from freezing is described. The method is shown to be technically and economically feasible. A prototype water heating system using the inherent freeze protection method was successfully operated during the winter of 1980 to 1981.

Jeter, S.M.; Leonaitis, L.L.; Leonaitis, L.L.

1981-05-01T23:59:59.000Z

127

Advances in the Research of Heat Pump Water Heaters  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future Vol.VIII-12-2 1 Advances in the Research of Heat Pump Water Heaters Shangli Shan Dandan Wang Ruixiang Wang Master Master Professor Beijing...) [21] Wang sui-lin . Affection on fin-and-tube Heat Exchanger's Properties by non azeotropic mixtures[J] . Fluid machinery , 1996 , 24 (5) [22] Ge run-ting . Foundation of Dynamic Parameter Model and Theoritical Calculation of Evaporator...

Shan, S.; Wang, D.; Wang, R.

2006-01-01T23:59:59.000Z

128

Electric Water Heater Modeling and Control Strategies for Demand Response  

SciTech Connect

Abstract Demand response (DR) has a great potential to provide balancing services at normal operating conditions and emergency support when a power system is subject to disturbances. Effective control strategies can significantly relieve the balancing burden of conventional generators and reduce investment on generation and transmission expansion. This paper is aimed at modeling electric water heaters (EWH) in households and tests their response to control strategies to implement DR. The open-loop response of EWH to a centralized signal is studied by adjusting temperature settings to provide regulation services; and two types of decentralized controllers are tested to provide frequency support following generator trips. EWH models are included in a simulation platform in DIgSILENT to perform electromechanical simulation, which contains 147 households in a distribution feeder. Simulation results show the dependence of EWH response on water heater usage . These results provide insight suggestions on the need of control strategies to achieve better performance for demand response implementation. Index Terms Centralized control, decentralized control, demand response, electrical water heater, smart grid

Diao, Ruisheng; Lu, Shuai; Elizondo, Marcelo A.; Mayhorn, Ebony T.; Zhang, Yu; Samaan, Nader A.

2012-07-22T23:59:59.000Z

129

Economic Analysis of Solar Water Heaters in GuangZhou  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Policy for Energy Efficiency and Comfort, Vol.VII-4-4 Economic Analysis of Solar Water Heaters in GuangZhou Ying Wang LiHua Zhao Graduated Student Associate Professor School of Architecture, South China... and lasting from a social benefit point of view in order to sustainable develop and ICEBO2006, Shenzhen, China Policy for Energy Efficiency and Comfort, Vol.VII-4-4 benefit our offspring. REFERENCES [1] Yi Yun, ShanMing Wang. Market insight of solar...

Wang, Y.; Zhao, L.

2006-01-01T23:59:59.000Z

130

An Evaluation of the Water Heater Load Potential for Providing Regulation Service  

SciTech Connect

This paper investigates the possibility of providing aggregated regulation services with small loads, such as water heaters or air conditioners. A direct-load control algorithm is presented to aggregate the water heater load for the purpose of regulation. A dual-element electric water heater model is developed, which accounts for both thermal dynamics and users water consumptions. A realistic regulation signal was used to evaluate the number of water heaters needed and the operational characteristics of a water heater when providing 2-MW regulation service. Modeling results suggest that approximately 33,333 water heaters are needed to provide a 2-MW regulation service 24 hours a day. However, if water heaters only provide regulation from 6:00 to 24:00, approximately 20,000 will be needed. Because the control algorithm has considered the thermal setting of the water heater, the customer comfort is obstructed little. Therefore, the aggregated regulation service provided by water heater loads can become a major source of revenue for load-service entities when the smart grid enables the direct load control.

Kondoh, Junji; Lu, Ning; Hammerstrom, Donald J.

2011-08-31T23:59:59.000Z

131

Sustainable Energy Resources for Consumers (SERC)- On-Demand Tankless Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

This presentation, aimed at Sustainable Energy Resources for Consumers (SERC) grantees, provides information on Monitoring Checklists for the installation of On-Demand Tankless Water Heaters.

132

Annual Operating Characteristics of Solar Central Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

The solar central water heater (SCWH) could supply ... massive users effectively and reliably. A SCWH assisted by heat pump (SCWHP) was proposed...

Wei Hu; Zhaolin Gu; Shiyu Feng; Xiufeng Gao

2009-01-01T23:59:59.000Z

133

Solar Hot Water Heater Augmented with PV-TEM Heat Pump.  

E-Print Network (OSTI)

??Solar assisted heat pumps (SAHPs) can provide higher collector efficiencies and solar fractions when compared against standard solar hot water heaters. Vapour compression (VC) heat (more)

PRESTON, NATHANIEL

134

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers  

E-Print Network (OSTI)

as conventional electric resistance water heaters. Atwo technologies: (1) an electric resistance storage waterin heat pump or in electric resistance mode. The electric

Lekov, Alex

2011-01-01T23:59:59.000Z

135

Gas-Fired Absorption Heat Pump Water Heater Research Project | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Gas-Fired Absorption Heat Pump Water Emerging Technologies » Gas-Fired Absorption Heat Pump Water Heater Research Project Gas-Fired Absorption Heat Pump Water Heater Research Project The U.S. Department of Energy (DOE) is currently conducting research into carbon gas-fired absorption heat pump water heaters. This project will employ innovative techniques to increase water heating energy efficiency over conventional gas storage water heaters by 40%. Project Description This project seeks to develop a natural gas-fired water heater using an absorption heat. The development effort is targeting lithium bromide aqueous solutions as a working fluid in order to avoid the negative implications of using more toxic ammonia. Project Partners Research is being undertaken through a Cooperative Research and Development

136

Energy Cost Calculator for Electric and Gas Water Heaters | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric and Gas Water Heaters Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters October 8, 2013 - 2:26pm Addthis Vary equipment size, energy cost, hours of operation, and /or efficiency level. INPUT SECTION Input the following data (if any parameter is missing, calculator will set to default value). Defaults Type of Water Heater Electric Gas Electric Average Daily Usage (gallons per day)* gallons 64* Energy Factor† 0.92 (electric) 0.61 (gas) Energy Cost $ / kWh $0.06 per kWh $.60 per therm Quantity of Water Heaters to be Purchased unit(s) 1 unit * See assumptions for various daily water use totals. † The comparison assumes a storage tank water heater as the input type. To allow demand water heaters as the comparison type, users can specify an input EF of up to 0.85; however, 0.66 is currently the best available EF for storage water heaters.

137

Building America Top Innovations Hall of Fame Profile … Tankless Gas Water Heater Performance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incorporating tankless water heaters was one Incorporating tankless water heaters was one of many energy-efficiency recommendations Building America's research team IBACOS had for San Antonio builder Imagine Homes. Although tankless gas water heaters should save approximately 33% on hot water heating compared to a conventional storage water heater, actual energy savings vary significantly based on individual draw volume. Above 10 gallons per draw, the efficiency approaches the rated energy factor. The greatest savings occur at a daily use quantity of about 50 gallons. BUILDING AMERICA TOP INNOVATIONS HALL OF FAME PROFILE INNOVATIONS CATEGORY: 1. Advanced Technologies and Practices 1.2 Energy Efficient Components Tankless Gas Water Heater Performance As improved thermal enclosures dramatically reduce heating and cooling loads,

138

Heat pump water heater and storage tank assembly  

DOE Patents (OSTI)

A water heater and storage tank assembly comprises a housing defining a chamber, an inlet for admitting cold water to the chamber, and an outlet for permitting flow of hot water from the chamber. A compressor is mounted on the housing and is removed from the chamber. A condenser comprises a tube adapted to receive refrigerant from the compressor, and winding around the chamber to impart heat to water in the chamber. An evaporator is mounted on the housing and removed from the chamber, the evaporator being adapted to receive refrigerant from the condenser and to discharge refrigerant to conduits in communication with the compressor. An electric resistance element extends into the chamber, and a thermostat is disposed in the chamber and is operative to sense water temperature and to actuate the resistance element upon the water temperature dropping to a selected level. The assembly includes a first connection at an external end of the inlet, a second connection at an external end of the outlet, and a third connection for connecting the resistance element, compressor and evaporator to an electrical power source.

Dieckmann, John T. (Belmont, MA); Nowicki, Brian J. (Watertown, MA); Teagan, W. Peter (Acton, MA); Zogg, Robert (Belmont, MA)

1999-09-07T23:59:59.000Z

139

Tankless water heaters fill the bill at fast-food restaurants  

SciTech Connect

This article explains why Kentucky Fried Chicken has installed a PH-24 water heater. The tankless water heater meets the restaurant's criteria for space spacing, flow rates, certification and availability, and money saving efficiency. This article describes the system and its advantages.

Not Available

1988-02-01T23:59:59.000Z

140

Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Homes Water Heating Swimming Pool Heaters Swimming Pool Heaters July 10, 2014 Gas Swimming Pool Heaters Selecting the right kind of swimming pool heater...

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates  

E-Print Network (OSTI)

Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads...

Johnson, K. F.; Shedd, A. C.

142

ENERGY STAR Residential Water Heaters to Save Americans Up to $823 Million  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

STAR Residential Water Heaters to Save Americans Up to $823 STAR Residential Water Heaters to Save Americans Up to $823 Million in the Next Five Years ENERGY STAR Residential Water Heaters to Save Americans Up to $823 Million in the Next Five Years December 31, 2008 - 9:18am Addthis WASHINGTON - The U.S. Department of Energy (DOE) today announced the availability of ENERGY STAR® residential water heaters. With today's announcement, the ENERGY STAR® program now addresses every major residential appliance found in most American homes. Introduction of this product provides significant potential savings to consumers. Water heating represents up to 15.5 percent of national residential energy consumption, the second largest end use of energy in homes, following heating and cooling. Using one of five specified water heating technologies, ENERGY

143

Economics of residential gas furnaces and water heaters in United States new construction market  

SciTech Connect

New single-family home construction represents a significant and important market for the introduction of energy-efficient gas-fired space heating and water-heating equipment. In the new construction market, the choice of furnace and water-heater type is primarily driven by first cost considerations and the availability of power vent and condensing water heaters. Few analysis have been performed to assess the economic impacts of the different combinations of space and water-heating equipment. Thus, equipment is often installed without taking into consideration the potential economic and energy savings of installing space and water-heating equipment combinations. In this study, we use a life-cycle cost analysis that accounts for uncertainty and variability of the analysis inputs to assess the economic benefits of gas furnace and water-heater design combinations. This study accounts not only for the equipment cost but also for the cost of installing, maintaining, repairing, and operating the equipment over its lifetime. Overall, this study, which is focused on US single-family new construction households that install gas furnaces and storage water heaters, finds that installing a condensing or power-vent water heater together with condensing furnace is the most cost-effective option for the majority of these houses. Furthermore, the findings suggest that the new construction residential market could be a target market for the large-scale introduction of a combination of condensing or power-vent water heaters with condensing furnaces.

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2009-05-06T23:59:59.000Z

144

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book (EERE)

5 5 Water Heater Efficiencies 2005 2010 Efficiency Stock Minimum Best-Available Residential Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage EF 0.90 0.90 (2) 0.95 (2) Electric Instantaneous EF 0.82 0.82 0.98 Electric Heat Pump EF 2.00 2.00 2.35 Gas-Fired Storage EF 0.60 0.59 (3) 0.85 (3) Gas-Fired Instantaneous EF 0.82 0.82 0.98 Oil-Fired Storage EF 0.50 0.53 (4) 0.68 (4) Solar SEF 2.50 N.A. 2.50 2007 2010 Efficiency Stock Minimum Best-Available Commercial Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage Thermal Efficiency 0.98 0.98 (5) 0.98 (5) Electric Instantaneous Thermal Efficiency 0.98 0.98 0.98 Gas-Fired Storage Thermal Efficiency 0.78 0.80 (6) 0.96 (6) Gas-Fired Instantaneous Thermal Efficiency 0.77 0.80 0.85 Oil-Fired Storage Thermal Efficiency 0.79 0.78 (7) 0.85 (7) Note(s):

145

Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

SciTech Connect

The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

2012-07-01T23:59:59.000Z

146

Economics of Residential Gas Furnaces and Water Heaters in United States  

NLE Websites -- All DOE Office Websites (Extended Search)

Economics of Residential Gas Furnaces and Water Heaters in United States Economics of Residential Gas Furnaces and Water Heaters in United States New Construction Market Speaker(s): Alex Lekov Gabrielle Wong-Parodi James McMahon Victor Franco Date: May 8, 2009 - 12:00pm Location: 90-3122 In the new single-family home construction market, the choice of what gas furnace and gas water heater combination to install is primarily driven by first cost considerations. In this study, the authors use a life-cycle cost analysis approach that accounts for uncertainty and variability of inputs to assess the economic benefits of installing different gas furnace and water heater combinations. Among other factors, it assesses the economic feasibility of eliminating the traditional metal vents and replacing them with vents made of plastic materials used in condensing and power vent

147

Critical Question #8: When are Heat Pump Water Heaters the Best Solution? |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8: When are Heat Pump Water Heaters the Best 8: When are Heat Pump Water Heaters the Best Solution? Critical Question #8: When are Heat Pump Water Heaters the Best Solution? What do we know about actual performance compared to promised performance? What is the best way to manage the space conditioning impacts on a home? Is there an easy decision tree for deciding if this is the best solution for a particular home (Climate? Utility prices? Accessibility? Physical space constraints? Workforce?)? cq8_residential_hpwh_costs_maguire.pdf cq8_hpwh_performance_colon.pdf cq8_hpwhs_multifamily_weitzel.pdf More Documents & Publications Track A - Energy Systems Innovations Illustrative Calculation of Economics for Heat Pump and "Grid-Enabled" Water Heaters Standing Technical Committee Working Sessions

148

Development and Application of Engineering-Scale Solar Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

An engineering-scale solar water heater system assisted by heat pump was developed based on ... . The subunits of modularized system include vacuum solar energy collectors, air source heat pump, ... Energy source...

Xiufeng Gao; Shiyu Feng; Wei Hu

2009-01-01T23:59:59.000Z

149

Design, modeling, and performance of four breadbox passive solar water heaters  

SciTech Connect

As part of the Southwest Border Regional Commission demonstration program on Solar Upgrading of Low-Income Housing, three different types of passive breadbox solar water heaters were designed. Using these designs, a total of six solar water heaters have been installed on public housing units in Las Cruces; these systems act as preheaters to the existing conventional gas-fired water heaters. Under a separate contract from the National Center for Appropriate Technology, four of these installations have been instrumented with two Btu meters each to measure the thermal output of both the solar preheater and conventional backup system. This has enabled measurement of the actual solar fraction of the four instrumented solar systems. The design and construction of the water heaters is described, and the actual performance of the systems is compared with the predicted performance.

Roberts, D. (Energy Management Services, Inc., Santa Fe, NM); Farrer, R.

1981-01-01T23:59:59.000Z

150

Regional Variation in Residential Heat Pump Water Heater Performance in the United States  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Regional Variation in Residential Heat Pump Water Heater Performance in the US Jeff Maguire 4/30/13 Outline * Why HPWHs? * US Water Heating Market * Overview of HPWHs * Model Description * Results o HPWH Performance o Energy Savings Potential o Breakeven Cost 2 Heat Pump Water Heaters Save $300 a year over standard electric? Save $100 a year over standard gas? Heat Pump Electric Gas 3 Questions about HPWHs * Are HPWHs a good replacement for typical gas and electric storage water heaters? o In different locations across the country? o In conditioned/unconditioned space? o Source energy savings?

151

City-level energy and CO2 reduction effect by introducing new residential water heaters  

Science Journals Connector (OSTI)

Simulation models for a variety of new water heater systems were developed and the models were integrated into a city-level residential energy end-use model for Osaka City. Using the model, the potential of energy conservation and CO2 emission-reduction by introducing new residential water heaters was evaluated at the city-level. Optimal water-heating systems for each household category for primary energy reduction, CO2 emission-reduction, or cost reduction were identified by applying the end-use demand model. The effect of subsidies for installing more efficient systems and the influence of diffusion of these systems on electricity load curves were also discussed.

Yoshiyuki Shimoda; Tomo Okamura; Yohei Yamaguchi; Yukio Yamaguchi; Ayako Taniguchi; Takao Morikawa

2010-01-01T23:59:59.000Z

152

Covered Product Category: Residential Heat Pump Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

used for many years for space heating and cooling. It can be found in small and large products alike, such as window air conditioners used in homes through large rooftop units...

153

The Newest Addition to the ENERGY STAR Lineup: Water Heaters | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Newest Addition to the ENERGY STAR Lineup: Water Heaters The Newest Addition to the ENERGY STAR Lineup: Water Heaters The Newest Addition to the ENERGY STAR Lineup: Water Heaters February 17, 2009 - 9:48am Addthis Elizabeth Spencer Communicator, National Renewable Energy Laboratory If you've gone shopping for new appliances sometime in the last decade, then you're probably familiar with the ENERGY STAR® label. ENERGY STAR is a partnership between the U.S. Department of Energy and the U.S. Environmental Protection Agency that sets higher-than-average standards for household appliances, electronics, and commercial products. Products that meet these rigorous energy requirements can be designated as ENERGY STAR products. For the average consumer, it basically means that ENERGY STAR products are more energy efficient than their standard counterparts, and therefore will

154

City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

San Jose - Solar Hot Water Heaters and Photovoltaic Systems San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements < Back Eligibility Commercial Construction Industrial Installer/Contractor Multi-Family Residential Residential Savings Category Solar Buying & Making Electricity Program Info State California Program Type Solar/Wind Permitting Standards Provider City of San Jose Building, Planning and Electrical Permits are required for Photovoltiac (PV) systems installed in San Jose. In most cases, PV systems must also undergo a Building Plan Review and an Electrical Plan Review. Building Plan Reviews are not required for installations that meet all of the following criteria: 1. Total panel weight (including frame) is not greater than 5 lbs. per

155

Feasibility of Using Measurements of Internal Components ofTankless Water Heaters for Field Monitoring of Energy and Water Use  

SciTech Connect

The objective of this study was to determine if it was feasible to collect information regarding energy use and hot water delivery from tankless gas water heaters using the sensors and controls built into the water heaters. This could then be used to determine the water heater efficiency ? the ratio of energy out (hot water delivered) to energy in (energy in the gas) in actual residential installations. The goal was to be as unobtrusive as possible, and to avoid invalidating warranties or exposing researchers to liability issues. If feasible this approach would reduce the costs of instrumentation.This paper describes the limited field and laboratory investigations to determine if using the sensors and controls built into tankless water heaters is feasible for field monitoring.It was more complicated to use the existing gas flow, water and temperature sensors than was anticipated. To get the signals from the existing sensors and controls is difficult and may involve making changes that would invalidate manufacturer warrantees. The procedures and methods for using signals from the existing gas valves, water flow meters and temperature sensors will vary by model. To be able to monitor different models and brands would require detailed information about each model and brand.Based on these findings, we believe that for field monitoring projects it would be easier, quicker and safer to connect external meters to measure the same parameters rather than using the sensors and controls built into tankless water heaters.

Lutz, Jim; Biermayer, Peter

2008-04-17T23:59:59.000Z

156

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

SciTech Connect

Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

Johnson, Alissa; Lutz, James; McNeil, Michael A.; Covary, Theo

2013-11-13T23:59:59.000Z

157

Performance of Heat Pump Water Heaters: Initial Findings of Draw Profile Effect on HPWH Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Performance of Heat Pump Water Heaters Performance of Heat Pump Water Heaters © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved. Evaluation Overview  2000-2002 Evaluated 20 installations with CL&P  Product had problems; not ready for prime time (average COPs of 1.67 was not the problem)  New batch of heaters available, including:  GE's GeoSpring Hybrid (50 gal)  A.O.Smith's Voltex Hybrid (60 & 80 gal)  Stiebel-Eltron's Accelera 300 (80 gal)  Evaluating 14 installations for National Grid, NSTAR, & Cape Light Compact. © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved.

158

Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Recommendations for Applying Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems A. Rudd, K. Ueno, D. Bergey, R. Osser Building Science Corporation June 2012 i This report received minimal editorial review at NREL. NOTICE This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, subcontractors, or affiliated partners makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark,

159

Field Performance of Heat Pump Water Heaters in the Northeast, Massachusetts and Rhode Island (Fact Sheet)  

SciTech Connect

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring, A.O. Smith Voltex, and Stiebel Eltron Accelera 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

Not Available

2013-12-01T23:59:59.000Z

160

Orlando Utilities Commission- Residential Solar Water Heater Rebate Program (Florida)  

Energy.gov (U.S. Department of Energy (DOE))

The Orlando Utilities Commission (OUC) offers residential electric customers a point-of-sale rebate of $1,000 for new solar water heating systems.

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim  

NLE Websites -- All DOE Office Websites (Extended Search)

TANK Water Heater Simulation Model as Embedded in HWSim TANK Water Heater Simulation Model as Embedded in HWSim Title Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim Publication Type Report LBNL Report Number LBNL-5092E Year of Publication 2010 Authors Lutz, James D. Document Number LBNL-5092E Pagination 11 Date Published December 22 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5092E Abstract This report evaluates the hot water temperatures and flow rates as calculated by the combined HWSim and TANK simulation models. Notes This work was sponsored by the Gas Technology Institute (GTI) which is funded by the California Energy Commission, Public Interest Energy Research (PIER) Program, under Residential Water Heating Program Contract No. 500-08-060. This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

162

Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models: Preprint  

SciTech Connect

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. Laboratory results demonstrate the efficiency of this technology under most of the conditions tested and show that differences in control schemes and design features impact the performance of the individual units. These results were used to understand current model limitations, and then to bracket the energy savings potential for HPWH technology in various US climate regions. Simulation results show that HPWHs are expected to provide significant energy savings in many climate zones when compared to other types of water heaters (up to 64%, including impact on HVAC systems).

Hudon, K.; Sparn, B.; Christensen, D.; Maguire, J.

2012-02-01T23:59:59.000Z

163

Refrigerant charge management in a heat pump water heater  

DOE Patents (OSTI)

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

Chen, Jie; Hampton, Justin W.

2014-06-24T23:59:59.000Z

164

Experimental study of a thermosyphon solar water heater coupled to a fibre-reinforced plastic (FRP) storage tank  

Science Journals Connector (OSTI)

The thermal performance of the thermosyphon solar water heater was analyzed to show its ... %. Also, an analysis of the temperature storage characteristics of a novel fibre-reinforced plastic (FRP) storage tank w...

P. N. Nwosu; O. U. Oparaku; W. I. Okonkwo; G. O. Unachukwu

2011-09-01T23:59:59.000Z

165

Performance Analysis of a Transcritical CO2 Heat Pump Water Heater Incorporating a Brazed-Plate Gas-cooler.  

E-Print Network (OSTI)

??This study focuses on the experimental testing and numerical modeling of a 4.5 kW transcritical CO2 heat pump water heater at Queens University in the (more)

Murray, PORTIA

2015-01-01T23:59:59.000Z

166

Analysis of water heater standby energy consumption from ELCAP homes  

Science Journals Connector (OSTI)

The Bonneville Power Administration (Bonneville) routinely prepares forecasts of future energy demands in the Pacific Northwest region of the United States. Bonneville also implements conservation programs to reduce load demands. Results from the End-Use Load and Consumer Assessment Program (ELCAP), undertaken by the Pacific Northwest Laboratory for Bonneville, indicated that single-family homes with electric space-heating equipment consume more than 4700 kWh/yr to heat water for domestic uses. This energy use amounts to about 23% of the total electricity consumed. Additionally, the peak consumption for water heating coincides with regional system peak demands. Detailed analyses of the water heating end-use data acquired for residential buildings in ELCAP reveal that the average standby load for existing homes is 1200 kWh/yr, while homes built as part of the Residential Standards Demonstration Program averaged 1100 kWh/yr. These figures are consistent with the current figure of 1300 kWh/yr that is being used in the regional energy forecast. We also determined that standby loads for some of the participants were behaviorally driven. The data indicated the occurrence of vacancy setbacks in which the participant appears to lower the thermostat to save energy while the house is vacant. Anecdotal evidence from interviews revealed that this does occur. Reasons for setting back the thermostat ranged from not thinking about using the breaker, to fear that the tank would freeze in cold weather. These types of activities also appear to create the occurrence of dueling thermostats where the upper and lower thermostats, after the vacancy period, are not returned to the same temperature. This leads to additional energy use in an attempt to maintain a uniform temperature in the tank.

R.G. Pratt; B.A. Ross; W.F. Sandusky

1993-01-01T23:59:59.000Z

167

Building America Expert Meeting: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

Energy.gov (U.S. Department of Energy (DOE))

The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

168

Control Strategy for Domestic Water Heaters during Peak Periods and its Impact on the Demand for Electricity  

Science Journals Connector (OSTI)

Because they store hot water, water heaters are easily-shifted loads that can be controlled to reduce peak demands. However, load shifting may have some detrimental consequences on the domestic hot water supply temperature if the heating element is deactivated for a long period of time. Furthermore, a new peak may be caused if a significant number of heaters are reactivated at the same time. This study presents a control strategy for water heaters that minimizes the pick-up demand when the heating elements are reactivated at the end of a load shifting period and that ensures, in all cases, the client's hot water supply. The study is based on a simulation model of a water heater that was experimentally validated and takes into account the diversity of the population's hot water withdrawal profile. More specifically, the data of 8,167 real water withdrawal profiles of several clients were input into the simulation model in order to evaluate the performance of water heaters under different operating conditions.

Alain Moreau

2011-01-01T23:59:59.000Z

169

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

170

Impact of Pilot Light Modeling on the Predicted Annual Performance of Residential Gas Water Heaters: Preprint  

SciTech Connect

Modeling residential water heaters with dynamic simulation models can provide accurate estimates of their annual energy consumption, if the units? characteristics and use conditions are known. Most gas storage water heaters (GSWHs) include a standing pilot light. It is generally assumed that the pilot light energy will help make up standby losses and have no impact on the predicted annual energy consumption. However, that is not always the case. The gas input rate and conversion efficiency of a pilot light for a GSWH were determined from laboratory data. The data were used in simulations of a typical GSWH with and without a pilot light, for two cases: 1) the GSWH is used alone; and 2) the GSWH is the second tank in a solar water heating (SWH) system. The sensitivity of wasted pilot light energy to annual hot water use, climate, and installation location was examined. The GSWH used alone in unconditioned space in a hot climate had a slight increase in energy consumption. The GSWH with a pilot light used as a backup to an SWH used up to 80% more auxiliary energy than one without in hot, sunny locations, from increased tank losses.

Maguire, J.; Burch, J.

2013-08-01T23:59:59.000Z

171

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)  

SciTech Connect

Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

Metzger, C.; Puttagunta, S.; Williamson, J.

2013-11-01T23:59:59.000Z

172

Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort  

SciTech Connect

Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

2014-07-21T23:59:59.000Z

173

Microsoft Word - ASHRAE_Water Heater Paper_2010-11-24_Final_LBNL_.docx  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers Presented at: 2011 ASHRAE Winter Conference, Las Vegas, Nevada January 2011 Alex B. Lekov, Victor H. Franco, Steve Meyers, Lisa Thompson, and Virginie Letschert Lawrence Berkeley National Laboratory Environmental Energy Technologies Division One Cyclotron Road Berkeley, CA 94720 This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY 2 Disclaimer This document was prepared as an account of work sponsored by the United States

174

2014-06-27 Issuance: Test Procedures for Residential and Commercial Water Heaters; Final Rule  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register final rule regarding test procedures for residential and commercial water heaters, as issued by the Deputy Assistant Secretary for Energy Efficiency on June 27, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

175

Modeling of Electric Water Heaters for Demand Response: A Baseline PDE Model  

SciTech Connect

Demand response (DR)control can effectively relieve balancing and frequency regulation burdens on conventional generators, facilitate integrating more renewable energy, and reduce generation and transmission investments needed to meet peak demands. Electric water heaters (EWHs) have a great potential in implementing DR control strategies because: (a) the EWH power consumption has a high correlation with daily load patterns; (b) they constitute a significant percentage of domestic electrical load; (c) the heating element is a resistor, without reactive power consumption; and (d) they can be used as energy storage devices when needed. Accurately modeling the dynamic behavior of EWHs is essential for designing DR controls. Various water heater models, simplified to different extents, were published in the literature; however, few of them were validated against field measurements, which may result in inaccuracy when implementing DR controls. In this paper, a partial differential equation physics-based model, developed to capture detailed temperature profiles at different tank locations, is validated against field test data for more than 10 days. The developed model shows very good performance in capturing water thermal dynamics for benchmark testing purposes

Xu, Zhijie; Diao, Ruisheng; Lu, Shuai; Lian, Jianming; Zhang, Yu

2014-09-05T23:59:59.000Z

176

Effect of Fuel Wobbe Number on Pollutant Emissions from Advanced Technology Residential Water Heaters: Results of Controlled Experiments  

SciTech Connect

The research summarized in this report is part of a larger effort to evaluate the potential air quality impacts of using liquefied natural gas in California. A difference of potential importance between many liquefied natural gas blends and the natural gas blends that have been distributed in California in recent years is the higher Wobbe number of liquefied natural gas. Wobbe number is a measure of the energy delivery rate for appliances that use orifice- or pressure-based fuel metering. The effect of Wobbe number on pollutant emissions from residential water heaters was evaluated in controlled experiments. Experiments were conducted on eight storage water heaters, including five with ultra low-NO{sub X} burners, and four on-demand (tankless) water heaters, all of which featured ultra low-NO{sub X} burners. Pollutant emissions were quantified as air-free concentrations in the appliance flue and fuel-based emission factors in units of nanogram of pollutant emitter per joule of fuel energy consumed. Emissions were measured for carbon monoxide (CO), nitrogen oxides (NO{sub X}), nitrogen oxide (NO), formaldehyde and acetaldehyde as the water heaters were operated through defined operating cycles using fuels with varying Wobbe number. The reference fuel was Northern California line gas with Wobbe number ranging from 1344 to 1365. Test fuels had Wobbe numbers of 1360, 1390 and 1420. The most prominent finding was an increase in NO{sub X} emissions with increasing Wobbe number: all five of the ultra low-NO{sub X} storage water heaters and two of the four ultra low-NO{sub X} on-demand water heaters had statistically discernible (p<0.10) increases in NO{sub X} with fuel Wobbe number. The largest percentage increases occurred for the ultra low-NO{sub X} water heaters. There was a discernible change in CO emissions with Wobbe number for all four of the on-demand devices tested. The on-demand water heater with the highest CO emissions also had the largest CO increase with increasing fuel Wobbe number.

Rapp, VH; Singer, BC

2014-03-01T23:59:59.000Z

177

Development of Environmentally Benign Heat Pump Water Heaters for the US Market  

SciTech Connect

Improving energy efficiency in water heating applications is important to the nation's energy strategies. Water heating in residential and commercial buildings accounts for about 10% of U.S. buildings energy consumption. Heat pump water heating (HPWH) technology is a significant breakthrough in energy efficiency, as an alternative to electric resistance water heating. Heat pump technology has shown acceptable payback period with proper incentives and successful market penetration is emerging. However, current HPWH require the use of refrigerants with high Global Warming Potential (GWP). Furthermore, current system designs depend greatly on the backup resistance heaters when the ambient temperature is below freezing or when hot water demand increases. Finally, the performance of current HPWH technology degrades greatly as the water set point temperature exceeds 330 K. This paper presents the potential for carbon dioxide, CO2, as a natural, environmentally benign alternative refrigerant for HPWH technology. In this paper, we first describe the system design, implications and opportunities of operating a transcritical cycle. Next, a prototype CO2 HPWH design featuring flexible component evaluation capability is described. The experimental setup and results are then illustrated followed by a brief discussion on the measured system performance. The paper ends with conclusions and recommendations for the development of CO2 heat pump water heating technology suitable for the U.S. market.

Abdelaziz, Omar [ORNL] [ORNL; Wang, Kai [ORNL] [ORNL; Vineyard, Edward Allan [ORNL] [ORNL; Roetker, Jack [General Electric - Appliance Park] [General Electric - Appliance Park

2012-01-01T23:59:59.000Z

178

National Solar Water Heater Workshop Present at DOE Region V meeting for managers of State Energy Extension Service and State Energy Conservation Plan, March 18-19, 1981  

SciTech Connect

After a brief description of the National Solar Water Heater Workshop and some comments by users of the solar water heater, the hardware supplier handbook is presented. The performance expected of a hardware supplier is described, solar system components and their specifications are listed, and information is provided to assist the hardware supplier in obtaining necessary materials. (LEW)

Mumma, S.A.; Marinello, M.G.

1981-01-01T23:59:59.000Z

179

Building America Technology Solutions for New and Existing Homes: Multifamily Central Heat Pump Water Heaters (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

To evaluate the performance of central heat pump water heaters for multifamily applications, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California, for 16 months.

180

Thermal performance analysis of a direct-expansion solar-assisted heat pump water heater  

Science Journals Connector (OSTI)

A direct-expansion solar-assisted heat pump water heater (DX-SAHPWH) is described, which can supply hot water for domestic use during the whole year. The system mainly employs a bare flat-plate collector/evaporator with a surface area of 4.2m2, an electrical rotary-type hermetic compressor, a hot water tank with the volume of 150L and a thermostatic expansion valve. R-22 is used as working fluid in the system. A simulation model based on lumped and distributed parameter approach is developed to predict the thermal performance of the system. Given the structure parameters, meteorological parameters, time step and final water temperature, the numerical model can output operational parameters, such as heat capacity, system COP and collector efficiency. Comparisons between the simulation results and the experimental measurements show that the model is able to give satisfactory predictions. The effect of various parameters, including solar radiation, ambient temperature, wind speed and compressor speed, has been analyzed on the thermal performance of the system.

X.Q. Kong; D. Zhang; Y. Li; Q.M. Yang

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Building America Technology Solutions for New and Existing Homes: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a heat pump water heater in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

182

Experimental investigation of the night heat losses of hot water storage tanks in thermosyphon solar water heaters  

Science Journals Connector (OSTI)

The effects of night heat losses on the performance of thermosyphon solar water heaters have been experimentally examined. Three typical thermosyphon solar water heating systems with different storage tank sizes were tested by utilising the method suggested by ISO 9459-2:95. The results were analysed to quantify the night heat losses and to investigate the effect that these may have on the system daily performance. Analysis of the results showed that a linear behavior of the heat losses with the night mean ambient temperature exists. The correlation coefficients of the linearity for the three systems under consideration range from 0.93 to 0.97 with the losses reaching almost 8000 kJ at a mean ambient air temperature of 10 C. This value represents a significant percentage of the daily collected energy making the night losses one of the most important sources of energy loss in thermosyphonic systems.

Ioannis Michaelides; Polyvios Eleftheriou; George A. Siamas; George Roditis; Paraskevas Kyriacou

2011-01-01T23:59:59.000Z

183

Feasibility study of broadband efficient ''water window'' source  

SciTech Connect

We demonstrate a table-top broadband emission water window source based on laser-produced high-Z plasmas. Resonance emission from multiply charged ions merges to produce intense unresolved transition arrays (UTAs) in the 2-4 nm region, extending below the carbon K edge (4.37 nm). Arrays resulting from n=4-n=4 transitions are overlaid with n=4-n=5 emission and shift to shorter wavelength with increasing atomic number. An outline of a microscope design for single-shot live cell imaging is proposed based on a bismuth plasma UTA source, coupled to multilayer mirror optics.

Higashiguchi, Takeshi; Yugami, Noboru [Department of Advanced Interdisciplinary Sciences, Center for Optical Research and Education (CORE), and Optical Technology Innovation Center (OpTIC), Utsunomiya University, Yoto 7-1-2, Utsunomiya, Tochigi 321-8585 (Japan); Japan Science and Technology Agency, CREST, 4-1-8 Honcho, Kanagawa, Saitama 332-0012 (Japan); Otsuka, Takamitsu [Department of Advanced Interdisciplinary Sciences, Center for Optical Research and Education (CORE), and Optical Technology Innovation Center (OpTIC), Utsunomiya University, Yoto 7-1-2, Utsunomiya, Tochigi 321-8585 (Japan); Jiang Weihua [Department of Electrical Engineering, Nagaoka University of Technology, Kami-tomiokamachi 1603-1, Nagaoka, Niigata 940-2188 (Japan); Endo, Akira [Research Institute for Science and Engineering, Waseda University, Okubo 3-4-1, Shinjuku, Tokyo 169-8555 (Japan); Li Bowen; Dunne, Padraig; O'Sullivan, Gerry [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland)

2012-01-02T23:59:59.000Z

184

Short term performance comparisons between a solar thermosyphon water heater and two numerical models  

SciTech Connect

An experimental study of a solar thermosyphon domestic water heater was conducted in the indoor solar simulator facility at Colorado State University (Bickford, 1994). The system consisted of a closed-loop collector circuit filled with propylene glycol and water solution and a horizontal storage tank with an annular tank-in-tank heat exchanger. Short-term irradiated tests with and without timed draws were performed to assess overall performance and monitor collector flow rate, storage tank stratification, and heat exchanger temperature distribution. The measured performance was compared with the ``standard`` thermosyphon model in TRNSYS 13.1 (transient system simulation program). A revised TRNSYS model was developed by Graham Morrison at the University of New South Wales, Australia. The revised model specifically addressed the horizontal tank, closed-loop configuration. The standard TRNSYS version predicted solar gain within 17% of the measured values and differed dramatically from experimental collector temperatures, closed-loop flow rate, and tank stratification. This is not surprising since this model does not include the tank and tank heat exchanger. The revised TRNSYS model agreed more closely with experimental results. It predicted closed-loop flow at 8% lower than observed flow and collector temperature rise that was higher than the observed flow by approximately the same amount, resulting in extremely accurate prediction of collector output energy. Losses from the storage tank and piping were significantly underpredicted in both models, however.

Bickford, C.; Hittle, D.C. [Colorado State Univ., Fort Collins, CO (United States). Solar Energy Applications Lab.

1995-11-01T23:59:59.000Z

185

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet), NREL Highlights, Research & Development, NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

simulation model helps researchers evaluate real-world simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes. Heat pump water heaters (HPWHs) remove heat from the air and use it to heat water, presenting an energy-saving opportunity for homeowners. Researchers at the National Renewable Energy Laboratory (NREL) developed a simulation model to study the inter- actions of HPWHs and space conditioning equipment, related to climate and installa- tion location in the home. This model was created in TRNSYS and is based on data from HPWHs tested at NREL's Advanced HVAC Systems Laboratory. The HPWH model accounts for the condenser coil wrapped around the outside of the storage tank, and uses a data-based performance map. Researchers found that simulated energy use was within 2% of lab results, which confirms

186

Development of minimum efficiency standards for large capacity air conditioners, and commercial water heaters, refrigerators, and freezers. Final report  

SciTech Connect

The California Energy Resources Conservation and Development Commission has promulgated appliance energy efficiency standards and energy conservation standards for new construction with the objective of reducing energy consumption in the State of California. The following appliance categories are specifically addressed: large capacity air conditioners; commercial water heaters; and commercial refrigerators and freezers. The tasks that have been performed include: an energy use pattern study for the subject equipment; an examination of the size distribution of commercial air conditioning equipment; an examination of the different types of commercial air conditioning systems; an evaluation of the effectiveness of economizers in reducing commercial air conditioning system energy consumption in California; an examination of the effects of oversizing commercial air conditioners; a detailed study of supermarket refrigeration and air conditioning equipment; an evaluation of the economic feasibility of utilizing air conditioner waste heat to heat water; an assessment of the applicability of existing test procedures for small water heaters to large water heaters; and a brief investigation of the marketing and distribution systems for air conditioning and refrigeration equipment. Results of the efforts are described.

Merrill, P.S.; Rettberg, R.J.; Erickson, R.C.; Toor, J.S.

1980-05-01T23:59:59.000Z

187

Development of a cogenerating thermophotovoltaic powered combination hot water heater/hydronic boiler  

Science Journals Connector (OSTI)

A cogenerating thermophotovoltaic (TPV) device for hot water hydronic space heating and electric power generation was developed designed fabricated and tested under a Department of Energy contracted program. The device utilizes a cylindrical ytterbia superemissive ceramic fiber burner (SCFB) and is designed for a nominal capacity of 80 kBtu/hr. The burner is fired with premixed natural gas and air. Narrow band emission from the SCFB is converted to electricity by single crystal silicon (Si) photovoltaic (PV) arrays arranged concentrically around the burner. A three-way mixing valve is used to direct heated water to either the portable water storage tank radiant baseboard heaters or both. As part of this program QGI developed a microprocessor-based control system to address the safety issues as well as photovoltaic power management. Flame sensing is accomplished via the photovoltaics a technology borrowed from QGIs Quantum Control safety shut-off system. Device testing demonstrated a nominal photovoltaic power output of 200 W. Power consumed during steady state operation was 33 W with power drawn from the combustion air blower hydronic system pump three-way switching valve and the control system resulting in a net power surplus of 142 W. Power drawn during the ignition sequence was 55 W and a battery recharge time of 1 minute 30 seconds was recorded. System efficiency was measured and found to be more than 83%. Pollutant emissions at determined operating conditions were below the South Coast Air Quality Management Districts (California) limit of 40 ng/J for NOx and carbon monoxide emissions were measured at less than 50 dppm.

Aleksandr S. Kushch; Steven M. Skinner; Richard Brennan; Pedro A. Sarmiento

1997-01-01T23:59:59.000Z

188

Building America Technology Solutions for New and Existing Homes: Field Performance of Heat Pump Water Heaters in the Northeast (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE))

In this project, the Consortium for Advanced Residential Buildings evaluated three newly released heat pump water heater products in order to provide publicly available field data on these products.

189

Water Window Ptychographic Imaging with Characterized Coherent X-rays  

E-Print Network (OSTI)

We report on a ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at $500~\\mathrm{eV}$. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of the PETRA III synchrotron radiation source. We measured the beam coherence with the newly developed non-redundant array method. A pinhole $2.6~\\mathrm{\\mu m}$ in size selected the coherent part of the beam and was used for ptychographic measurements of a lithographically manufactured test sample and fossil diatom. The achieved resolution was $53~\\mathrm{nm}$ for the test sample and only limited by the size of the detector. The diatom was imaged at a resolution better than $90~\\mathrm{nm}$.

Rose, Max; Dzhigaev, Dmitry; Gorobtsov, Oleg; Senkbeil, Tobias; von Gundlach, Andreas; Gorniak, Thomas; Shabalin, Anatoly; Viefhaus, Jens; Rosenhahn, Axel; Vartanyants, Ivan

2015-01-01T23:59:59.000Z

190

2014-10-14 Issuance: Test Procedures and Energy Conservation Standards for Residential Solar Water Heaters; Request for Information  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register request for information regarding test procedures and energy conservation standards for residential solar water heaters, as issued by the Deputy Assistant Secretary for Energy Efficiency on October 14, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

191

DOE Publishes Notice of Proposed Rulemaking for Residential Water...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Water Heater and Certain Commercial Water Heater Test Procedures DOE Publishes Notice of Proposed Rulemaking for Residential Water Heater and Certain Commercial Water Heater Test...

192

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Final report  

SciTech Connect

The Federal government is the largest single energy consumer in the United States with consumption of nearly 1.5 quads/year of energy (10{sup 15} quad = 1015 Btu) and cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP) seeks to evaluate new energy -- saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This report provides the results of a field evaluation that PNL conducted for DOE/FEMP with funding support from the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of 4 candidate energy-saving technology-a water heater conversion system to convert electrically powered water heaters to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-12-01T23:59:59.000Z

193

Auto-Calibration and Control Strategy Determination for a Variable-Speed Heat Pump Water Heater Using Optimization  

SciTech Connect

This paper introduces applications of the GenOpt optimizer coupled with a vapor compression system model for auto-calibration and control strategy determination towards the development of a variable-speed ground-source heat pump water heating unit. The GenOpt optimizer can be linked with any simulation program using input and output text files. It effectively facilitates optimization runs. Using our GenOpt wrapper program, we can flexibly define objectives for optimizations, targets, and constraints. Those functionalities enable running extensive optimization cases for model calibration, configuration design and control strategy determination. In addition, we describe a methodology to improve prediction accuracy using functional calibration curves. Using the calibrated model, we investigated control strategies of the ground-source heat pump water heater, considering multiple control objectives, covering the entire operation range.

Shen, Bo [ORNL] [ORNL; Abdelaziz, Omar [ORNL] [ORNL; Rice, C Keith [ORNL] [ORNL

2012-01-01T23:59:59.000Z

194

Radiation Efficiency of Water-Window Cherenkov Sources Using Atomic Shell Resonances  

Science Journals Connector (OSTI)

We developed simple theory of Cherenkov radiation at atomic resonances in the X-ray water window for L-shells in 5 trans-oxigen elements and proposed K-shell resonance in liquid...

Kaplan, Alexander E; Shkolnikov, Peter L

195

Solar-assisted auto-cascade heat pump cycle with zeotropic mixture R32/R290 for small water heaters  

Science Journals Connector (OSTI)

Abstract In this study, a novel solar-assisted auto-cascade heat pump cycle (SAHPC) operating with the zeotropic mixture of R32/R290 for small water heaters is proposed. In the SAHPC system, a cascade heat exchanger (CHEX) associated with a phase separator is used to achieve auto cascade cycle and enhance the overall system performance. The performances of the SAHPC are evaluated by using the developed mathematical model, and then compared with the conventional air-sourced heat pump cycle (CAHPC). Simulation results show the SAHPC has 4.239.85% and 4.379.68% improvements in COP and volumetric heating capacity compared with those of the CAHPC, respectively, under the same operating conditions. However, the improvement of performance of this novel cycle largely depends on the absorbing heat ratio and the zeotropic composition. It is expected that this new cycle will be beneficial to developing dual-source coupled heat pump applications.

Xiaolong Lv; Gang Yan; Jianlin Yu

2015-01-01T23:59:59.000Z

196

Review of experiments to evaluate the ability of electrical heater rods to simulate nuclear fuel rod behavior during postulated loss-of-coolant accidents in light water reactors  

SciTech Connect

Issues related to using electrical fuel rod simulators to simulate nuclear fuel rod behavior during postulated loss-of-coolant accident (LOCA) conditions in light water reactors are summarized. Experimental programs which will provide a data base for comparing electrical heater rod and nuclear fuel rod LOCA responses are reviewed.

McPherson, G D; Tolman, E L

1980-01-01T23:59:59.000Z

197

Convective heater  

DOE Patents (OSTI)

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1983-01-01T23:59:59.000Z

198

Convective heater  

DOE Patents (OSTI)

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1986-01-01T23:59:59.000Z

199

Solar Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Swimming Pool Heaters Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool A flow control valve -- automatic or manual device that diverts pool

200

Solar Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Swimming Pool Heaters Solar Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network (OSTI)

hot water distribution losses and waste heat recovery.Distribution losses are those heat losses that occur betweenDistribution losses Smart controls Wasted water Solar Heat

Lutz, Jim

2012-01-01T23:59:59.000Z

202

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network (OSTI)

air source to be added Discharge Includes: Source energy multiplier Distribution losses Smart controls Wasted water Solar Heat pump

Lutz, Jim

2012-01-01T23:59:59.000Z

203

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Interim report, 1994 Summer  

SciTech Connect

The federal government is the largest single energy consumer in the United States cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This interim report provides the results of a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology-a hot water heater conversion system to convert electrically heated hot water tanks to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-01-01T23:59:59.000Z

204

Performance of Gas-fired Water Heaters in a 10-home Field Study  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "Are high-efficiency hot water heating systems worth the cost?"

205

Efficiency of a parabolic trough collector as a water heater system in Yucatn, Mexico  

Science Journals Connector (OSTI)

The performance of a parabolic trough collector (PTC) manufactured in Merida Yucatn was evaluated under the ANSI/ASHRAE 93-1986 standard. The water heating system for testing with a constant flow limited to a maximum temperature of 55 C was built; thus the tests were at low temperatures. Using water as working fluid it was found that the maximum efficiency of the collector was 5.43% with a flow rate of 0.022?kg/s at a direct solar irradiance with incidence angle 0. The evaluation methodology and design of the system for testing the collector is reported in this paper.

N. Rosado Hau; M. A. Escalante Soberanis

2011-01-01T23:59:59.000Z

206

Analysis of field-test data from domestic solar-water heaters in the southern United States, period through September 1982  

SciTech Connect

The monitored performance data used here was gathered from 137 solar water heaters. All but 51 are located in Florida. The gathered data accumulated from weekly mailers consists of the following measurements: total gallons of hot water consumed; total kWh of electricity used; total hours the circulating pump operated; hot and cold water temperatures at the top; number of household members at home since last reading; tank thermostat setting and any changes to it; total number of hours that the tank's backup heating element had power available; and problems or comments concerning system operational status or component reliability and maintenance. The data analysis is described and results are presented. (MHR)

Jones, W.M.; Fenner, M.F.

1983-01-01T23:59:59.000Z

207

ELECTRICAL HEATERS FOR THERMO-MECHANICAL TESTS AT THE STRIPA MINE  

E-Print Network (OSTI)

5.5 Dewatering Pump 6. ELECTRICAL HEATER CONTROL SYSTEMS 6.1water influx ABSTRACT Electrical heaters were installed atcanister) which houses the electrical heater elements; c. d.

Burleigh, R.H.

2010-01-01T23:59:59.000Z

208

Feasibility of Using Measurements of Internal Components of Tankless Water Heaters for Field Monitoring of Energy and Water Use  

E-Print Network (OSTI)

speed motor that modulates the blower speed, this watermotor amps Energy Efficiency versus gas input for both waterWater flow versus gas input At this site we also compared gas consumption to blower motor

Lutz, Jim

2008-01-01T23:59:59.000Z

209

Water Heaters (Storage Electric)  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR verification, DOE rulemakings, and enforcement of the federal energy conservation standards.

210

Movable insulation. A guide to reducing heating and cooling losses through the windows in your home  

SciTech Connect

A typical house loses 25 to 30% of its heat through windows, and a house with large windows may lose as much as 50%. Numerous movable-insulation systems that will cut the heat loss through windows in half are described. Chapters are: The Energy-Responsive Dwelling, Past to Present; Window Heat Losses and Gains; Enhanced Glazing Systems; Choosing a Window-Insulation Design for Your Home; Pop-In Shutters; Thermal Curtains - Blankets that Fold; Thermal Shades - Blankets that Roll; Thermal Shutters and Folding Screens; Insulation Between Glazing and Interior Louvers; Exterior Hinged and Sliding Shutters; Sun-Shading Screens; Exterior Roll Shutters; Shutters for Skylights; Shutters for Clerestory Windows; Interior Greenhouse Insulation Systems; Exterior Insulation for Greenhouses; Movable Insulation to Assist Passive Space Heating; and Movable Insulation to Assist Solar Water Heaters. Appendices include the following: insulated shade and shutter construction; the economics of window insulation; movable insulation products, hardware, and components; further technical information; and design sources. (MCW)

Langdon, W.K.

1980-01-01T23:59:59.000Z

211

Soft X-Ray Emission in the Water Window Region with Nitrogen Filling in a Low Energy Plasma Focus  

Science Journals Connector (OSTI)

For operation of the plasma focus in nitrogen, a focus pinch compression temperature...62נ106...K) is found to be suitable for good yield of nitrogen soft X-rays in the water window region. Using this temperat...

M. Akel; S. Lee

2013-02-01T23:59:59.000Z

212

Solar heater for swimming pools  

SciTech Connect

A solar heater for swimming pools is provided having one or more heating panels installable on a roof or the like and arranged to discharge into a pool equipped with an apron without need for disturbing or obstructing the apron. This is accomplished by the provision of an elevated bistable dumper adjacent the perimeter of the apron having a dispensing spout normally inclined upwardly but pivoting at intervals to discharge into the pool across the apron without obstructing it. Water to be heated is diverted from the pool filtering system to the solar heater via a pressure regulator and a solar responsive flow control.

Babcock, H.W.

1984-12-04T23:59:59.000Z

213

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Performance of a Performance of a Heat Pump Water Heater in the Hot-Humid Climate Windermere, Florida Over recent years, heat pump water heaters (HPWHs) have become more read- ily available and more widely adopted in the marketplace. A key feature of an HPWH unit is that it is a hybrid system. When conditions are favorable, the unit will operate in heat pump mode (using a vapor compression system that extracts heat from the surrounding air) to efficiently provide domestic hot water (DHW). Homeowners need not adjust their behavior to conform to the heat pump's capabilities. If a heat pump cannot meet a higher water draw demand, the heater will switch to electric resistance to provide a higher heating rate. This flexibility

214

Water Heating | Department of Energy  

Energy Savers (EERE)

Energy Saver Water Heating Water Heating Infographic: Water Heaters 101 Infographic: Water Heaters 101 Everything you need to know about saving money on water heating costs....

215

The minimum gas temperature at the inlet of regulators in natural gas pressure reduction stations (CGS) for energy saving in water bath heaters  

Science Journals Connector (OSTI)

Abstract In this study a computational procedure for the computation of JouleThomson coefficient of natural gas has been developed using fundamental thermodynamic equations and AGA-8 equation of state, and then the minimum possible temperature of the natural gas entering to the pressure regulator of city gate stations (CGS) is calculated. As a case study, a CGS located in Bistoon (of Iran's CGSs) with nominal capacity of 20,000 SCMH has been considered. A comparison has been made between the calculated results and corresponding collected data from the station within 10 months. Results of this study help to determine the minimum temperature values of entering gas with different pressures to the regulator in order to avoid hydrate formation of the outlet gas, and can be used to design appropriate temperature control systems for water bath heaters and in turn save consumed energy for gas heating. The results show that heating the gas up to calculated minimum temperatures can save energy consumption of heaters by 43%. Also, it is indicated that by applying a control system, based on the result of this study, in the CGS the payback period would be less than a year.

Esmail Ashouri; Farzad Veysi; Ehsan Shojaeizadeh; Maryam Asadi

2014-01-01T23:59:59.000Z

216

Grouped exposed metal heaters  

DOE Patents (OSTI)

A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

Vinegar, Harold J. (Bellaire, TX); Coit, William George (Bellaire, TX); Griffin, Peter Terry (Brixham, GB); Hamilton, Paul Taylor (Houston, TX); Hsu, Chia-Fu (Granada Hills, CA); Mason, Stanley Leroy (Allen, TX); Samuel, Allan James (Kular Lumpar, MY); Watkins, Ronnie Wade (Cypress, TX)

2010-11-09T23:59:59.000Z

217

Excitation wavelength dependence of water-window line emissions from boron-nitride laser-produced plasmas  

SciTech Connect

We investigated the effects of laser excitation wavelength on water-window emission lines of laser-produced boron-nitride plasmas. Plasmas are produced by focusing 1064 nm and harmonically generated 532 and 266 nm radiation from a Nd:YAG laser on BN target in vacuum. Soft x-ray emission lines in the water-window region are recorded using a grazing-incidence spectrograph. Filtered photodiodes are used to obtain complementary data for water-window emission intensity and angular dependence. Spectral emission intensity changes in nitrogen Ly-{alpha} and He-{alpha} are used to show how laser wavelength affects emission. Our results show that the relative intensity of spectral lines is laser wavelength dependent, with the ratio of Ly-{alpha} to He-{alpha} emission intensity decreasing as laser wavelength is shortened. Filtered photodiode measurements of angular dependence showed that 266 and 532 nm laser wavelengths produce uniform emission.

Crank, M.; Harilal, S. S.; Hassan, S. M.; Hassanein, A. [Center for Materials Under Extreme Environment, School of Nuclear Engineering, Purdue University, West Lafayette, Indiana 47907 (United States)

2012-02-01T23:59:59.000Z

218

Spatio-temporal isolation of attosecond soft X-ray pulses in the water window  

E-Print Network (OSTI)

We demonstrate experimentally the isolation of single attosecond pulses at the carbon K- shell edge in the soft-X-ray water window. Attosecond pulses at photon energies that cover the principal absorption edges of the building blocks of materials are a prerequisite for time resolved probing of the triggering events leading to electronic dynamics such as exciton formation and annihilation. Herewith, we demonstrate successful isolation of individual attosecond pulses at the carbon K edge (284 eV) with a pulse duration below 400 as and with a bandwidth supporting a 30 as pulse duration. Our approach is based on spatio-temporal isolation of ponderomotively shifted harmonics and validates a straightforward and scalable approach for robust and reproducible attosecond pulse isolation.

Silva, Francisco; Cousin, Seth L; Hemmer, Michael; Biegert, Jens

2014-01-01T23:59:59.000Z

219

'Water window' sources: Selection based on the interplay of spectral properties and multilayer reflection bandwidth  

SciTech Connect

Development of laser-produced plasma 'water window' sources poses a major challenge in x-ray research and most effort has focused on line sources for use with zone plate optics. Here, a comparison of carbon and nitrogen line emission with that from both 3d - 4f and 4d - 4f unresolved transition arrays shows that, at power densities available from 'table-top' solid-state lasers, 3d - 4f emission from zirconium plasmas is most intense, and calculations show that in an imaging system based on multilayer mirrors, for reflectance bandwidths >1% has superior performance than either line or broader-band sources. For bandwidths <1%, line sources are preferable.

Li, Bowen; Dunne, Padraig; O'Sullivan, Gerry [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland)] [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland); Higashiguchi, Takeshi; Otsuka, Takamitsu [Department of Advanced Interdisciplinary Sciences, Center for Optical Research and Education (CORE), and Optical Technology Innovation Center (OpTIC), Utsunomiya University, Yoto 7-1-2, Utsunomiya, Tochigi 321-8585 (Japan)] [Department of Advanced Interdisciplinary Sciences, Center for Optical Research and Education (CORE), and Optical Technology Innovation Center (OpTIC), Utsunomiya University, Yoto 7-1-2, Utsunomiya, Tochigi 321-8585 (Japan); Jiang, Weihua [Department of Electrical Engineering, Nagaoka University of Technology, Kami-tomiokamachi 1603-1, Nagaoka, Niigata 940-2188 (Japan)] [Department of Electrical Engineering, Nagaoka University of Technology, Kami-tomiokamachi 1603-1, Nagaoka, Niigata 940-2188 (Japan); Endo, Akira [HiLASE Project, Institute of Physics AS, CR, Na Slovance 2, 18221 Prague 8 (Czech Republic)] [HiLASE Project, Institute of Physics AS, CR, Na Slovance 2, 18221 Prague 8 (Czech Republic)

2013-01-28T23:59:59.000Z

220

Explosives tester with heater  

DOE Patents (OSTI)

An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.

Del Eckels, Joel (Livermore, CA); Nunes, Peter J. (Danville, CA); Simpson, Randall L. (Livermore, CA); Whipple, Richard E. (Livermore, CA); Carter, J. Chance (Livermore, CA); Reynolds, John G. (San Ramon, CA)

2010-08-10T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Water Heating | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

to cut your water heating bill. Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water Heaters A water heater's energy efficiency is determined by the energy...

222

Department of Energy - Swimming Pool Heaters  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

736189 en Gas Swimming Pool Heaters http:energy.govenergysaverarticlesgas-swimming-pool-heaters heaters" class"title-link">

223

Heat Pump Swimming Pool Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Swimming Pool Heaters Swimming Pool Heaters Heat Pump Swimming Pool Heaters May 29, 2012 - 1:49pm Addthis How a heat pump works. How a heat pump works. How They Work Heat pumps use electricity to capture heat and move it from one place to another. They don't generate heat. As the pool pump circulates the swimming pool's water, the water drawn from the pool passes through a filter and the heat pump heater. The heat pump heater has a fan that draws in the outside air and directs it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor increases the heat, creating a very hot gas that then passes through the condenser. The condenser transfers the heat from the hot gas to the cooler pool water circulating

224

Solar pool heaters: The simplest use of active solar energy  

SciTech Connect

Solar pool heating is the most attractive solar water heating market today, because most pool heaters pay back their purchase price in lower utility bills in two to three years. This article describes why solar pool heaters are popular and their design, operation, and return on investment. 1 fig.

Sheinkopf, K. [Florida Solar Energy Center, Cocoa, FL (United States)

1997-11-01T23:59:59.000Z

225

Floating solar pool heater  

SciTech Connect

A floating solar heater for swimming pools is disclosed which includes a top cover, a vertical outer side wall with inclined inner side wall segments connected thereto, an outside rim and a bottom wall. The inner side wall segments are octagonal, coated with light reflective material, and aid in reflecting the sun's rays to heat the space inside the walls formed by the cover which dead air space also provides for floatation of the heater. The bottom wall is heated by direct sun inpingement and by the air in contact with it and is formed of a material having high heat conductivity.

McCluskey, J.E.

1981-08-18T23:59:59.000Z

226

Development of a gas backup heater for solar domestic hot-water systems. Final report, April 1978-April 1980  

SciTech Connect

A comprehensive program was undertaken to develop a unique gas fired backup for solar domestic hot water systems. Detailed computer design tools were written. A series of heat transfer experiments were performed to characterize the performance of individual components. A full scale engineering prototype, including the solar preheat tank and solar heat exchanger, was designed, fabricated and subjected to limited testing. Firing efficiency for the backup system was found to be 81.4% at a firing rate of 50,000 Btu/h. Long term standby losses should be negligible.

Morrison, D.J.; Grunes, H.E.; de Winter, F.; Armstrong, P.R.

1980-06-01T23:59:59.000Z

227

Portable Heaters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Portable Heaters Portable Heaters Portable Heaters November 26, 2013 - 2:41pm Addthis Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com What does this mean for me? A portable heater is a good choice if you have a space that requires supplemental heating or is infrequently occupied. You should carefully follow all the manufacturer's installation and operation instructions. Small space heaters are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. In some cases, small space heaters can be less expensive to use if you only want to heat one room or supplement inadequate heating in one room. They

228

Energy Conservation in Process Heaters  

E-Print Network (OSTI)

ENERGY CONSERVATION IN PROCESS HEATERS Roger l~. Bagge Neste Engineering Porvoo, Finland ABSTRACT OPTIMIZATION OF EMER~Y USE Energy savings in refinery and petrochemical fired heaters can basically be achieved in two ways: Thru optimization...

Bagge, R. W.

1982-01-01T23:59:59.000Z

229

Immersible solar heater for fluids  

DOE Patents (OSTI)

An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Kronberg, James W. (Aiken, SC)

1995-01-01T23:59:59.000Z

230

Covered Product Category: Residential Electric Resistance Water...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric Resistance Water Heaters Covered Product Category: Residential Electric Resistance Water Heaters The Federal Energy Management Program (FEMP) sets Federal efficiency...

231

Immersible solar heater for fluids  

DOE Patents (OSTI)

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Hazen, T.C.; Fliermans, C.B.

1994-01-01T23:59:59.000Z

232

Immersible solar heater for fluids  

DOE Patents (OSTI)

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

Kronberg, J.W.

1995-07-11T23:59:59.000Z

233

Window Properties  

NLE Websites -- All DOE Office Websites (Extended Search)

Window Properties: measurements, simulations and ratings Window Properties: measurements, simulations and ratings Determining the thermal and optical performance of window systems is essential to researchers striving to develop improved products and to window manufacturers who need to demonstrate the energy performance of their products to architects, engineers, builders, and the general public. LBNL is involved in basic research in this field, in developing software and test procedures to analyze and quantify window heat transfer and optics, and in developing standards and rating procedures. Infrared Laboratory experiments provide surface temperature maps of window products. A companion Traversing System measures air velocity and air temperatures near the surface of test specimens. The MoWiTT facility provides accurate measurements of the heat flow through complete window systems subjected to real weather conditions. MoWiTT results have been used to validate the performance of emerging technologies and research prototypes as well as to validate thermal performance models.

234

Methods for forming long subsurface heaters  

DOE Patents (OSTI)

A method for forming a longitudinal subsurface heater includes longitudinally welding an electrically conductive sheath of an insulated conductor heater along at least one longitudinal strip of metal. The longitudinal strip is formed into a tubular around the insulated conductor heater with the insulated conductor heater welded along the inside surface of the tubular.

Kim, Dong Sub

2013-09-17T23:59:59.000Z

235

Heater head for stirling engine  

DOE Patents (OSTI)

A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

Corey, John A. (R.D. #2, Box 101 E, North Troy, NY 12182)

1985-07-09T23:59:59.000Z

236

Phase change material storage heater  

DOE Patents (OSTI)

A storage heater for storing heat and for heating a fluid, such as water, has an enclosure defining a chamber therein. The chamber has a lower portion and an upper portion with a heating element being disposed within the enclosure. A tube through which the fluid flows has an inlet and an outlet, both being disposed outside of the enclosure, and has a portion interconnecting the inlet and the outlet that passes through the enclosure. A densely packed bed of phase change material pellets is disposed within the enclosure and is surrounded by a viscous liquid, such as propylene glycol. The viscous liquid is in thermal communication with the heating element, the phase change material pellets, and the tube and transfers heat from the heating element to the pellets and from the pellets to the tube. The viscous fluid has a viscosity so that the frictional pressure drop of the fluid in contact with the phase change material pellets substantially reduces vertical thermal convection in the fluid. As the fluid flows through the tube heat is transferred from the viscous liquid to the fluid flowing through the tube, thereby heating the fluid.

Goswami, D. Yogi (Gainesville, FL); Hsieh, Chung K. (Gainesville, FL); Jotshi, Chand K. (Gainesville, FL); Klausner, James F. (Gainesville, FL)

1997-01-01T23:59:59.000Z

237

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

from controlling heat loss through the distribution pipes.distribution system configurations; a collection of analytical heat lossdistribution system configurations; a collection of analytical heat loss

Lutz, Jim

2012-01-01T23:59:59.000Z

238

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

Building Energy Efficiency Standards .. 4 Multi-FamilyBuilding Energy Efficiency Standards 11 Multi-FamilyBuilding Energy Efficiency Standards 48 Multi-Family

Lutz, Jim

2012-01-01T23:59:59.000Z

239

The water vapour self- and waternitrogen continuum absorption in the 1000 and 2500?cm?1 atmospheric windows  

Science Journals Connector (OSTI)

...measurements with a multi-pass cell, shown in figure-2 by...would like to thank the NIST Physics Laboratory Management for the...atmospheric fluxes and cooling rates: application to water vapor...base-length White-type multi-pass cell coupled with a BOMEM DA3-002...

2012-01-01T23:59:59.000Z

240

Small Space Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Space Heater Basics Small Space Heater Basics Small Space Heater Basics August 19, 2013 - 10:38am Addthis Small space heaters, also called portable heaters, are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. Space heater capacities generally range between 10,000 Btu to 40,000 Btu per hour. Common fuels used for this purpose are electricity, propane, natural gas, and kerosene. Although most space heaters rely on convection (the circulation of air in a room), some rely on radiant heating; that is, they emit infrared radiation that directly heats up objects and people that are within their line of sight. Combustion Space Heaters Space heaters are classified as vented and unvented, or "vent free." Unvented combustion units are not recommended for inside use, as they

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Repair Existing Windows Repair Existing Windows Lead Paint and Window Replacement: Challenges and Opportunities In older homes, windows are a likely source of lead contamination in homes. Dust from lead paint can create serious health problems, especially in young children. While window replacement can increase lead dust during renovation, it can also permanently eliminate lead hazards by removing lead-painted windows. Download fact sheet» A variety of options exist for improving the energy-efficiency of your existing windows. Before investing in these options, check your windows for potential issues that may call for replacement instead: Moisture and mold between window frame and wall: If water and water vapors are allowed to penetrate around the window frame, the moisture can

242

A performance correlation of horizontal solar heaters  

E-Print Network (OSTI)

The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL... The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL...

Gopffarth, Wilford Hugo

2012-06-07T23:59:59.000Z

243

Heater head for Stirling engine  

SciTech Connect

This patent describes a heater head for a Stirling engine comprising: a housing for enclosing the heater head with gas at a substantial elevated pressure; insulator means attached to the housing for insulating the heater head; inlet means attached to a regenerator in the housing for admission of relatively high pressure working fluid from the regenerator of a Stirling engine; a first annular heating wall in the housing attached to the inlet means for heating the working fluid; and, a second annular heating wall in the housing concentric with the first heating wall but of lesser diameters so that an annular space is formed between the first heating wall and the second heating wall for heating working fluid; and a third heating wall in the housing concentric with and smaller in diameter than the second heating wall forming the condensing area of a heat pipe between the second heating wall and the third heating wall.

White, M.A.; Emigh, S.G.

1987-06-09T23:59:59.000Z

244

An internal winding high temperature heater  

Science Journals Connector (OSTI)

An internal winding high temperature heater ... General principles are outlined for the construction of compact heaters that are suitable for heating small containers or reaction vessels at constant temperature and up to about 1000 C. ...

A. J. Delbouille; E. G. Derouane

1973-01-01T23:59:59.000Z

245

Energy conversion by an electric space heater  

Science Journals Connector (OSTI)

By means of measuring the temperature of the air blown by an electric space heater one can show students that the air is heated at a rate approximately equal to the rated wattage of the heater.

Willem H. van den Berg

1998-01-01T23:59:59.000Z

246

Water Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heating Water Heating Water Heating Infographic: Water Heaters 101 Everything you need to know about saving money on water heating costs Read more Selecting a New Water Heater Tankless? Storage? Solar? Save money on your water heating bill by choosing the right type of energy-efficient water heater for your needs. Read more Sizing a New Water Heater When buying a new water heater, bigger is not always better. Learn how to buy the right size of water heater. Read more You can reduce your monthly water heating bills by selecting the appropriate water heater for your home or pool and by using some energy-efficient water heating strategies. Some simple do-it-yourself projects, like insulating hot water pipes and lowering your water heating temperature, can also help you save money and energy on your water heating.

247

Oil and Gas Air Heaters  

E-Print Network (OSTI)

ICEBO2006, Shenzhen, China Heating technologies for energy efficiency Vol.III-1-2 Oil and Gas Air Heaters1 Guangxiao Kou Hanqing Wang Jiemin Zhou Doctoral Ph.D Ph.D Candidate Professor Professor Hunan University of Technology Hunan...

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

248

Spring Home Maintenance: Windows, Windows, Windows! | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Spring Home Maintenance: Windows, Windows, Windows! Spring Home Maintenance: Windows, Windows, Windows! Spring Home Maintenance: Windows, Windows, Windows! April 26, 2013 - 11:42am Addthis Caulking is an easy way to reduce air leakage around your windows. | Photo courtesy of ©iStockphoto.com/BanksPhotos Caulking is an easy way to reduce air leakage around your windows. | Photo courtesy of ©iStockphoto.com/BanksPhotos Erin Connealy Communications Specialist, Office of Energy Efficiency and Renewable Energy How can I participate? Use these tips for window maintence and treatments to save energy this spring. The beginning of spring marks the point in the year when I'm cleaning, purging the house of things I no longer need, and updating my home on needed repairs. This year, I'm focusing on how to lower my energy bills

249

Spring Home Maintenance: Windows, Windows, Windows! | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Home Maintenance: Windows, Windows, Windows! Home Maintenance: Windows, Windows, Windows! Spring Home Maintenance: Windows, Windows, Windows! April 26, 2013 - 11:42am Addthis Caulking is an easy way to reduce air leakage around your windows. | Photo courtesy of ©iStockphoto.com/BanksPhotos Caulking is an easy way to reduce air leakage around your windows. | Photo courtesy of ©iStockphoto.com/BanksPhotos Erin Connealy Communications Specialist, Office of Energy Efficiency and Renewable Energy How can I participate? Use these tips for window maintence and treatments to save energy this spring. The beginning of spring marks the point in the year when I'm cleaning, purging the house of things I no longer need, and updating my home on needed repairs. This year, I'm focusing on how to lower my energy bills

250

Advancement of Electrochromic Windows  

E-Print Network (OSTI)

Guide for Early-Market Electrochromic Windows. LBNL-59950.Guide for Early-Market Electrochromic Windows Attachment 17:electrochromic prototype windows that were deemed sufficiently mature for market

2006-01-01T23:59:59.000Z

251

Zero Energy Windows  

E-Print Network (OSTI)

Energy Performance of Electrochromic Windows Controlled for2006). Advancement of Electrochromic Windows, CaliforniaSavings Potential of Electrochromic Windows in the U.S.

Arasteh, Dariush; Selkowitz, Steve; Apte, Josh; LaFrance, Marc

2006-01-01T23:59:59.000Z

252

Welding shield for coupling heaters  

DOE Patents (OSTI)

Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.

Menotti, James Louis (Dickinson, TX)

2010-03-09T23:59:59.000Z

253

Regenerative Boiler Feedwater Heater Economics  

E-Print Network (OSTI)

REGENERATIVE BOILER FEEDWATER HEATER ECONOMICS William L. Viar, PE waterland, Viar & Associates, Inc. Wilmington, Delaware ABSTRACT The basic Rankine Vapor Cycle has been r,~peatedly modified to improve efficiency. Always, the objective....g., first and second laws of thermodynamics) have improved and contributed to the evolution. The demands for larger systems with higher performance have been persistent. Progress i ve changes in the app1icat ion of the fundamental Rankine cycle have...

Viar, W. L.

254

Performance improvement of direct- and indirect-fired heaters  

SciTech Connect

The operating performance of direct and indirect heaters is discussed, and principles and guidelines that can be applied to effect improvements in efficiency are presented. This paper also discusses the associated heater efficiencies and several useful operating techniques to approach the maximum, steady-state heater efficiency. The techniques presented apply to all types of direct-and indirect-fired heaters: salt bath heaters, propane vaporizers, heater/treaters, production heaters, and glycol and amine regenerators.

Sams, G.W.; Hunter, J.D.

1988-08-01T23:59:59.000Z

255

Adjusting alloy compositions for selected properties in temperature limited heaters  

DOE Patents (OSTI)

Heaters for treating a subsurface formation are described herein. Such heaters can be obtained by using the systems and methods described herein. The heater includes a heater section including iron, cobalt, and carbon. The heater section has a Curie temperature less than a phase transformation temperature. The Curie temperature is at least 740.degree. C. The heater section provides, when time varying current is applied to the heater section, an electrical resistance.

Brady; Michael Patrick (Oak Ridge, TN), Horton, Jr.; Joseph Arno (Oak Ridge, TN), Vitek; John Michael (Oak Ridge, TN)

2010-03-23T23:59:59.000Z

256

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

CGDB Import Into WINDOW CGDB Import Into WINDOW Updated: 11/14/12 Detailed Instructions for Importing CGDB data into WINDOW These instructions apply to either WINDOW 6 or 7. WINDOW 6 vs WINDOW 7 Because the database structure of WINDOW 6 is different that WINDOW 7, there are different CGDB files to go with each version of WINDOW. There are also different versions of the XML files for each version, because in WINDOW 7 some problems with the files were fixed. Setup of CGDB The CGDB consists of a WINDOW database of records in the Shading Layer, Shade Material Library, and Glass Library, as well as a set of text files for systems that reference BSDF XML files. Database: The installation will put two databases into the "LBNL Shared" directory: (the location will depend on your operating system):

257

CO2 Conversion By Nano Heaters  

SciTech Connect

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-03-11T23:59:59.000Z

258

CO2 Conversion By Nano Heaters  

ScienceCinema (OSTI)

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-06-23T23:59:59.000Z

259

Parallel heater system for subsurface formations  

DOE Patents (OSTI)

A heating system for a subsurface formation is disclosed. The system includes a plurality of substantially horizontally oriented or inclined heater sections located in a hydrocarbon containing layer in the formation. At least a portion of two of the heater sections are substantially parallel to each other. The ends of at least two of the heater sections in the layer are electrically coupled to a substantially horizontal, or inclined, electrical conductor oriented substantially perpendicular to the ends of the at least two heater sections.

Harris, Christopher Kelvin (Houston, TX); Karanikas, John Michael (Houston, TX); Nguyen, Scott Vinh (Houston, TX)

2011-10-25T23:59:59.000Z

260

Combustion heater for oil shale  

DOE Patents (OSTI)

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650 to 700/sup 0/C for use as a process heat source.

Mallon, R.; Walton, O.; Lewis, A.E.; Braun, R.

1983-09-21T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Combustion heater for oil shale  

DOE Patents (OSTI)

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650.degree.-700.degree. C. for use as a process heat source.

Mallon, Richard G. (Livermore, CA); Walton, Otis R. (Livermore, CA); Lewis, Arthur E. (Los Altos, CA); Braun, Robert L. (Livermore, CA)

1985-01-01T23:59:59.000Z

262

Window and Envelope Technologies Overview - 2014 BTO Peer Review...  

Energy Savers (EERE)

Research and Development Roadmap: Windows and Building Envelope Research & Development Roadmap: Emerging Water Heating Technologies Research & Development Roadmap: Emerging HVAC...

263

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Ensure Proper Installation of New Windows Ensure Proper Installation of New Windows Information Regarding Lead-based Hazards Comprehensive information about lead paint exit disclaimer by U.S. EPA Literature ASTM E 2112, "Standard Practice for Installation of Exterior Windows, Doors and Skylights." www.astm.org exit disclaimer Water Management Guide, Joseph W. Lstiburek, Energy & Environmental Building Association. www.eeba.org exit disclaimer Proper installation is necessary for optimal window performance, to ensure an airtight fit and avoid water leakage. Always follow manufacturers installation guidelines and use trained professionals for window installation. The Importance of Quality Window Installation Quite simply, windows are only as good as their installation. Proper installation will:

264

A Study on the Failure of Industrial Electric Heater  

E-Print Network (OSTI)

The break down mechanism of a cylindrical electric heater is investigated by studying the uneven heating behavior of the heater by measuring the surface temperature variation of the heater when it is subjected to a boundary condition of constant...

Chyu, M. C.

265

Field Demonstration of High Efficiency Gas Heaters  

Energy.gov (U.S. Department of Energy (DOE))

For many buildings that do not require space cooling, non-centralized equipment such as unit heaters provide space heating to building occupants. Unit heaters are a major source of energy use nationally, accounting for nearly 18% of primary space heating energy use for commercial buildings, and most prominently appear in warehouses, distribution centers, loading docks, etc.

266

Subsurface connection methods for subsurface heaters  

DOE Patents (OSTI)

A system for heating a subsurface formation is described. The system includes a first elongated heater in a first opening in the formation. The first elongated heater includes an exposed metal section in a portion of the first opening. The portion is below a layer of the formation to be heated. The exposed metal section is exposed to the formation. A second elongated heater is in a second opening in the formation. The second opening connects to the first opening at or near the portion of the first opening below the layer to be heated. At least a portion of an exposed metal section of the second elongated heater is electrically coupled to at least a portion of the exposed metal section of the first elongated heater in the portion of the first opening below the layer to be heated.

Vinegar, Harold J. (Bellaire, TX); Bass, Ronald Marshall (Houston, TX); Kim, Dong Sub (Sugar Land, TX); Mason, Stanley Leroy (Allen, TX); Stegemeier, George Leo (Houston, TX); Keltner, Thomas Joseph (Spring, TX); Carl, Jr., Frederick Gordon (Houston, TX)

2010-12-28T23:59:59.000Z

267

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

(6.3.74 -- February 14, 2012) Release Notes Updated: 02/15/13 If you find bugs, or if you think these have not been fixed, please do not hesitate to send an email to WINDOWHelp@lbl.gov to report your findings. Getting feedback from users is how we improve the program. WINDOW 6.3.74 Program Changes Window LIbrary: Window Types In previous versions of WINDOW 6.3, there were two different Window Type lists, with conflicting ID numbers, which resulted in the possibility of a Window Library made with one set of Window Types would become corrupted (the wrong Window Types assigned) if the database records were imported into a another database with the different Window Type list. To solve this problem, we have added a database "migration" with this version of WINDOW -- when it opens any older database, it will update the Window Types list to have the choices (and IDs) shown below and then it will also update all the Window Library records to map to the new Window Types based on what the records were set to originally.

268

THERMOSIPHON WATER HEATERS WITH HEAT EXCHANGERS  

E-Print Network (OSTI)

communications). Heat transfer fluid is 60% o-o1vco1 bycharacteristics, heat transfer fluids, flow resistances,of a non- freezing heat transfer fluid circulating in a loop

Mertol, Atila

2012-01-01T23:59:59.000Z

269

Field Monitoring Protocol: Heat Pump Water Heaters  

NLE Websites -- All DOE Office Websites (Extended Search)

SHR Sensible heat ratio T&RH Temperature and relative humidity TC Thermocouple UA Heat loss coefficient v Table of Contents List of Figures ......

270

Heat Pump Water Heater Performance in  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

271

LBNL Windows & Daylighting Software -- WINDOW  

NLE Websites -- All DOE Office Websites (Extended Search)

WINDOW WINDOW NFRC Certification Version Release Version Beta Version WINDOW 6.3 (For NFRC Certification and modeling Complex Glazing Systems) WINDOW 7.1 For modeling vacuum glazing, deflected glass, vertical venetian blinds and perforated screens WINDOW 7.2 For modeling Cellular Shades, in addition to vacuum glazing, deflected glass, vertical venetian blinds and perforated screens Download WINDOW 6.3 (for NFRC Certification and complex glazing systems) Download WINDOW 7.1 Download WINDOW 7.2 Knowledge Base (Check here first if you are experiencing a problem with the software) Knowledge Base (Check here first if you are experiencing a problem with the software) Knowledge Base (Check here first if you are experiencing a problem with the software) New Features

272

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

WINDOW 6 and THERM 6 Technical Documentation WINDOW 6 and THERM 6 Technical Documentation Algorithm Documentation WINDOW6 and THERM6 implement the ISO 15099 algorithms: bullet ISO 15099 The algorithms in WINDOW6 and THERM6 follow the procedures presented in ISO 15099: "Thermal performance of windows, doors and shading devices - Detailed calculations." See: http://webstore.ansi.org/ansidocstore/product.asp?sku=ISO+15099%3A2003 In addition to implementing ISO 15099 algorithms in WINDOW6 and THERM6, we have added additional capabilities to WINDOW6. The following reports and papers describe these additional capabilities and/or elaborate on ISO15099. bullet Thermal Algorithm Documentation for THERM6: Conrad 5 & Viewer 5 Technical and Programming Documentation June 20, 2006 bullet Thermal Algorithm Documentation for WINDOW6:

273

Advancement of Electrochromic Windows  

E-Print Network (OSTI)

of a thin-film ceramic electrochromic window: Field studyof a Thin-Film Ceramic Electrochromic Window: Field StudyEC window product characteristics The EC is a thin-film WO3-

2006-01-01T23:59:59.000Z

274

Advancement of Electrochromic Windows  

E-Print Network (OSTI)

Guide for Early-Market Electrochromic Windows. LBNL-59950.Granqvist, C.G. 2000. "Electrochromic Tungsten Oxide Films:the performance of the electrochromic windows. Proceedings

2006-01-01T23:59:59.000Z

275

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Specular Glazing Systems Specular Glazing Systems NFRC THERM 6.3 / WINDOW 6.3 Simulation Manual July 2013: bullet Entire Manual in PDF Format approximate 8 MB Comparison of WINDOW 5 / THERM 5 and WINDOW 6 / THERM 6 Results for Specular Glazing Systems (PDF Format) NFRC WINDOW 6 / THERM 6 Training for Specular Systems (Power Point Presentation, Oct/Nov 2010) Tutorials Complex Glazing Systems bullet WINDOW 6.2 / THERM 6.2 Research Version User Manual (Documents features in WINDOW6 and THERM 6 for modeling complex glazing systems) bullet WINDOW 6.2 / THERM 6.2 Simulation Manual Chapter for Complex Glazing (Draft) This was used for NFRC Simulator training in June 2009, and includes detailed descriptions for modeling venetian blinds between glass and frits. bullet Complex Glazing Summary -- PDF File

276

Excitation wavelength dependence of water-window line emissions from boron-nitride laser-produced plasmas  

E-Print Network (OSTI)

transmission x-ray micro- scopes (STXM) have achieved high resolution ($30 nm) using zone plate condensers to their compact size, high brightness, and high conversion efficiency. The properties of EUV and SXR emission from for cellular microscopy. At these wavelengths transmission through water is relatively high compared to carbon

Harilal, S. S.

277

Connate Water Saturation -Irreducible or Not: the Key to Reliable Hydraulic Rock Typing in Reservoirs Straddling Multiple Capillary Windows  

E-Print Network (OSTI)

of flow capacity. High in-situ capillary pressure causes connate water saturation in reservoir rocks with core-calibrated Timur-Tixier's permeability model, both of which are expressions of porosity method in detecting and ranking reservoir rock types in complex contexts of reservoir saturation

Torres-Verdín, Carlos

278

Heater head for a Stirling engine  

SciTech Connect

A heater head is described for a compound Stirling engine modules, each including a displacer cylinder coaxially aligned with the displacer cylinder of the other of the engine modules, a displacer piston mounted for reciprocation in the displacer cylinder.

Darooka, D.K.

1988-09-06T23:59:59.000Z

279

Varying properties along lengths of temperature limited heaters  

DOE Patents (OSTI)

A system for heating a subsurface formation is described. The system includes an elongated heater in an opening in the formation. The elongated heater includes two or more portions along the length of the heater that have different power outputs. At least one portion of the elongated heater includes at least one temperature limited portion with at least one selected temperature at which the portion provides a reduced heat output. The heater is configured to provide heat to the formation with the different power outputs. The heater is configured so that the heater heats one or more portions of the formation at one or more selected heating rates.

Vinegar, Harold J. (Bellaire, TX); Xie, Xueying (Houston, TX); Miller, David Scott (Katy, TX); Ginestra, Jean Charles (Richmond, TX)

2011-07-26T23:59:59.000Z

280

Diesel particulate filter with zoned resistive heater  

DOE Patents (OSTI)

A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

Gonze, Eugene V [Pinckney, MI

2011-03-08T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Reducing NOx in Fired Heaters and Boilers  

E-Print Network (OSTI)

-6, 2000 Reducing NOx in Fired Heaters Air Pollution Control and Boilers Keeping the environment clean Presented by Ashutosh Garg Furnace Improvements Low cost solutions for fired heaters Trace compounds ? Nitric oxides ? Carbon monoxide ? Sulfur... it is essential to estimate accurately baseline NOx emissions. ? This will establish each units current compliance status. ? Emissions ? Current excess air level ? Carbon monoxide ? Combustibles ? NOx corrected to 3% 02 314 ESL-IE-00-04-46 Proceedings...

Garg, A.

282

High Performance Window Attachments  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Performance Window High Performance Window Attachments D. Charlie Curcija Lawrence Berkeley National Laboratory dccurcija@lbl.gov 510-495-2602 April 4, 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Impact of Project: * Motivate manufacturers to make improvements in Window systems U-Factors, SHGC and daylighting utilization * Increase awareness of benefits from energy efficient window attachments Problem Statement: * A wide range of residential window attachments are available, but they have widely unknown

283

NREL and Industry Advance Low-Cost Solar Water Heating R&D (Fact Sheet)  

SciTech Connect

NREL and Rhotech develop cost-effective solar water heating prototype to rival natural gas water heater market.

Not Available

2014-08-01T23:59:59.000Z

284

Tips: Water Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Water Heating Tips: Water Heating Tips: Water Heating May 2, 2012 - 4:53pm Addthis Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Water heating is the second largest energy expense in your home. It typically accounts for about 18% of your utility bill. There are four ways to cut your water heating bills: use less hot water, turn down the thermostat on your water heater, insulate your water heater, or buy a new, more efficient model. Water Heating Tips Install aerating, low-flow faucets and showerheads. Repair leaky faucets promptly; a leaky faucet wastes gallons of

285

Tips: Water Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heating Water Heating Tips: Water Heating May 2, 2012 - 4:53pm Addthis Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Water heating is the second largest energy expense in your home. It typically accounts for about 18% of your utility bill. There are four ways to cut your water heating bills: use less hot water, turn down the thermostat on your water heater, insulate your water heater, or buy a new, more efficient model. Water Heating Tips Install aerating, low-flow faucets and showerheads. Repair leaky faucets promptly; a leaky faucet wastes gallons of

286

The Efficient Window Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

5 5 The Efficient Window Collaborative http://www.efficientwindows.org Energy-efficient windows make up only about 35% of the U.S. residential window market, even though they are cost-effective in approximately 80% or more of all applications. To ensure that efficient windows reach their optimum potential in homes throughout the U.S., the Department of Energy and key players in the U.S. window industry have formed the Efficient Window Collaborative (EWC). The EWC's goal is doubling the market share of efficient windows by 2005. With 31 charter members from the window and glass industries, the EWC is managed jointly by the Washington, D.C.-based Alliance to Save Energy and the Center for Building Science's Windows and Daylighting Group. The EWC serves as a focal point for voluntary

287

NEXT GENERATION COMMERCIAL HEAT PUMPWATER HEATER USING CARBON DIOXIDE USING DIFFERENT IMPROVEMENT APPROACHES  

SciTech Connect

Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82?ºC, as required by sanitary codes in the U.S. (Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35 kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20 %.

Chad Bowers; Michael Petersen; Stefan Elbel; Pega Hrnjak

2012-04-01T23:59:59.000Z

288

window.xp  

NLE Websites -- All DOE Office Websites (Extended Search)

New New in Building Energy Efficiency Selecting Windows for Energy Efficiency New window technologies have increased energy benefits and comfort, and have provided more practical options for consumers. This selection guide will help homeowners, architects, and builders take advantage of the expanding window market. The guide contains three sections: an explanation of energy-related window characteristics, a discussion of window energy performance ratings, and a convenient checklist for window selection. S electing the right window for a specific home invariably requires tradeoffs between dif- ferent energy performance features, and with other non-energy issues. An understanding of some basic energy concepts is therefore essential to choosing appropriate windows and skylights. As illustrated on the fol-

289

Advanced Windows Test Facility  

NLE Websites -- All DOE Office Websites (Extended Search)

Exterior of Advanced Windows Test Facility Exterior of Advanced Windows Test Facility Advanced Windows Test Facility This multi-room laboratory's purpose is to test the performance and properties of advanced windows and window systems such as electrochromic windows, and automatically controlled shutters and blinds. The lab simulates real-world office spaces. Embedded instrumentation throughout the lab records solar gains and losses for specified time periods, weather conditions, energy use, and human comfort indicators. Electrochromic glazings promise to be a major advance in energy-efficient window technology, helping to achieve the goal of transforming windows and skylights from an energy liability in buildings to an energy source. The glazing can be reversibly switched from a clear to a transparent, colored

290

Temperature limited heaters using phase transformation of ferromagnetic material  

DOE Patents (OSTI)

Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.

Vitek, John Michael [Oak Ridge, TN; Brady, Michael Patrick [Oak Ridge, TN

2009-10-06T23:59:59.000Z

291

MHD oxidant intermediate temperature ceramic heater study. Final report  

SciTech Connect

The use of three types of directly fired ceramic heaters for preheating oxygen enriched air to an intermediate temperature of 1144K was investigated. The three types of ceramic heaters are: (1) a fixed bed, periodic flow ceramic brick regenerative heater (2) a ceramic pebble regenerative heater. The heater design, performance and operating characteristics under conditions in which the particulate matter is not solidified are evaluated. A comparison and overall evaluation of the three types of ceramic heaters and temperature range determination at which the particulate matter in the MHD exhaust gas is estimated to be a dry powder are presented.

Carlson, A.W.; Chait, I.L.; Saari, D.P.; Marksberry, C.L.

1981-09-01T23:59:59.000Z

292

Water-Heating Dehumidifier  

A small appliance developed at ORNL dehumidifies air and then recycles heat to warm water in a water heater. The device circulates cool, dry air in summer and warm air in winter. In addition, the invention can cut the energy required to run a conventional water heater by an estimated 50 per cent....

2010-12-08T23:59:59.000Z

293

Combination fence and solar heater for swimming pools  

SciTech Connect

A combination fence and solar heater for swimming pools comprises a fence shaped for extending about the periphery of the pool to restrict ingress and egress therefrom. A tubular heat exchanger is formed in at least one section of the fence, includes an exterior surface adapted to absorb solar energy, and communicates with the water in the swimming pool. The number of heat exchanger fence sections can be varied in accordance with the climate in which the pool is located. A pump flows the water in the swimming pool through the heat exchanger fence sections during daylight hours, thereby simultaneously heating the water in the pool, and providing an attractive and protective safety barrier about the swimming pool.

Divine, D.L.

1981-07-28T23:59:59.000Z

294

Mobile Window Thermal Test  

NLE Websites -- All DOE Office Websites (Extended Search)

Mobile Window Thermal Test (MoWiTT) Facility Mobile Window Thermal Test (MoWiTT) Facility winter.jpg (469135 bytes) The window has come a long way since the days when it was a single pane of glass in a wood frame. Low-emissivity windows were designed to help buildings retain some of the energy that would have leaked out of less efficient windows. Designing efficient window-and-frame systems is one strategy for reducing the energy use of buildings. But the net energy flowing through a window is a combination of temperature- driven thermal flows and transmission of incident solar energy, both of which vary with time. U-factor and solar heat gain coefficient (SHGC), the window properties that control these flows, depend partly on ambient conditions. Window energy flows can affect how much energy a building uses, depending on when the window flows are available to help meet other energy demands within the building, and when they are adverse, adding to building energy use. This leads to a second strategy for reducing building energy use: using the beneficial solar gain available through a window, either for winter heating or for daylighting, while minimizing adverse flows.

295

Design, Stress Analysis and Operating Experience in Feedwater Heaters  

E-Print Network (OSTI)

The performance of feedwater heaters has a direct bearing on the thermal efficiency of the plant. A typical feedwater heater may have three distinct regions of heat transfer, namely desuperheating, condensing and subcooling zones. The design...

Singh, K. P.; Libs, T.

1980-01-01T23:59:59.000Z

296

High Performance Windows Volume Purchase: The Windows Volume Purchase RFP  

NLE Websites -- All DOE Office Websites (Extended Search)

The Windows The Windows Volume Purchase RFP to someone by E-mail Share High Performance Windows Volume Purchase: The Windows Volume Purchase RFP on Facebook Tweet about High Performance Windows Volume Purchase: The Windows Volume Purchase RFP on Twitter Bookmark High Performance Windows Volume Purchase: The Windows Volume Purchase RFP on Google Bookmark High Performance Windows Volume Purchase: The Windows Volume Purchase RFP on Delicious Rank High Performance Windows Volume Purchase: The Windows Volume Purchase RFP on Digg Find More places to share High Performance Windows Volume Purchase: The Windows Volume Purchase RFP on AddThis.com... Home About FAQs Low-E Storm Windows Request for Proposal Contacts For Builders For Residential Buyers For Light Commercial Buyers For Manufacturers

297

Advancement of Electrochromic Windows  

NLE Websites -- All DOE Office Websites (Extended Search)

Advancement of Electrochromic Windows Advancement of Electrochromic Windows Title Advancement of Electrochromic Windows Publication Type Report LBNL Report Number LBNL-59821 Year of Publication 2006 Authors Lee, Eleanor S., Stephen E. Selkowitz, Robert D. Clear, Dennis L. DiBartolomeo, Joseph H. Klems, Luis L. Fernandes, Gregory J. Ward, Vorapat Inkarojrit, and Mehry Yazdanian Date Published 04/2006 Other Numbers CEC-500-2006-052 Keywords commercial buildings, daylight, daylighting controls, Electrochromic windows, energy efficiency, human factors, peak demand, switchable windows, visual comfort Abstract This guide provides consumer-oriented information about switchable electrochromic (EC) windows. Electrochromic windows change tint with a small applied voltage, providing building owners and occupants with the option to have clear or tinted windows at any time, irrespective of whether it's sunny or cloudy. EC windows can be manually or automatically controlled based on daylight, solar heat gain, glare, view, energy-efficiency, peak electricity demand response, or other criteria. Window controls can be integrated with other building systems, such as lighting and heating/cooling mechanical systems, to optimize interior environmental conditions, occupant comfort, and energy-efficiency.

298

SOFT COST GRAND CHALLENGE  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

fans, attic fans Envelope Windows, doors, air sealing, insulation, cool roof Mechanical Solar Water Heater, High-efficiency water heater, High-efficiency HVAC, ducts & seals,...

299

Windows and Daylighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Office building exterior Office building exterior Windows and Daylighting Windows research is aimed at improving energy efficiency in buildings and homes across the nation. Research includes: New glazing materials Windows simulation software Advanced high-performance fenestration systems Daylighting technologies Measurement of window properties Windows performance in residential and commercial buildings. Contacts Stephen Selkowitz SESelkowitz@lbl.gov (510) 486-5064 Eleanor Lee ESLee@lbl.gov (510) 486-4997 Charlie Curcija DCCurcija@lbl.gov (510) 495-2602 Links Windows and Daylighting Daylighting the New York Times Headquarters Building Batteries and Fuel Cells Buildings Energy Efficiency Applications Commercial Buildings Cool Roofs and Heat Islands Demand Response Energy Efficiency Program and Market Trends

300

Highly Insulating Windows - Publ  

NLE Websites -- All DOE Office Websites (Extended Search)

Highly Insulating Windows - Publications Future Advanced Windows for Zero-Energy Homes, J. Apte, D. Arasteh, J. Huang, 2003 ASHRAE Annual Meeting, 2002 Nine representative window products are examined in eight representative U.S. climates. Annual energy and peak demand impacts are investigated. We conclude that a new generation of window products is necessary for zero-energy homes if windows are not to be an energy drain on these homes. Performance Criteria for Residential Zero Energy Windows, D. Arasteh, H. Goudey, J. Huang, C. Kohler, R. Mitchell, 2006, submitted to ASHRAE Through the use of whole house energy modeling, typical efficient products are evaluated in five US climates and compared against the requirements for ZEHs. Products which meet these needs are defined as a function of climate.

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Highly Insulating Window Technology  

NLE Websites -- All DOE Office Websites (Extended Search)

Window Technology Window Technology Temperature differentials across a window, particularly with cold exterior environments in residential buildings, can lead to significant energy losses. Currently available low-emissivity coatings, gas-fills, and insulating frames provide significant energy savings over typical single or double glazed products. The EWC website provides information on how double glazed low-e gas-filled windows work as well as information on commercially available superwindows (three layer, multiple low-e coatings, high performance gas-fills). The next generation of highly insulating window systems will benefit from incremental improvements being made to current components (i.e. more insulating spacers and frame materials/designs, low-e coatings with improved performance properties). LBNL uses its experimental facilities and software tools to collaborate with window and glass industry representatives to better understand the impacts of new components on overall product performance.

302

Window industry technology roadmap  

SciTech Connect

Technology roadmap describing technology vision, barriers, and RD and D goals and strategies compiled by window industry stakeholders and government agencies.

Brandegee

2000-04-27T23:59:59.000Z

303

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Optics 6.0 Optics 6.0 (6.0 -- February 13, 2012) Release Notes Updated: 07/16/12 Program Changes Microsoft Windows 7 / Vista Operating System"Aware" Optics now installs and operates much better under the Microsoft Windows 7 and Vista operating systems. It is no longer necessary to run the "VistaFix" batch file after installing the program. Fixed Bugs If you find bugs, or if you think these have not been fixed, please do not hesitate to send an email to OpticsHelp@lbl.gov to report your findings. Getting feedback from users is how we improve the program. Paths Appear in Tools/Options In the Microsoft Windows 7 / Vista Operating System environments, the program would not display the directory paths in the Tools / Options "File Locations" dialog box. This is now fixed.

304

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Cellular / Honeycomb Shades Cellular / Honeycomb Shades Updated 09/30/2013 It is now possible to model cellular / honeycomb shading systems in the Shading System Library and then add them to a glazing system in the Glazing System Library. NOTE: Before attempting to calculate a glazing system with a cellular shade, you must make the following change to the THERM7.ini file, which is located in C:\Users\Public\LBNL\Settings. Close WINDOW7 before making this change. DocPath=C:\Users\Public\LBNL\WINDOW7\debug Shading Layer Library A cellular / honeycomb shade can now be defined in the Shading Layer Library. Defining this type of shading system requires an XML file which contains information about the cell geometry and the material thermal and optical properties. WINDOW can model two different types of cellular shades:

305

Eleana near-surface heater experiment final report  

SciTech Connect

This report summarizes the results of a near-surface heater experiment operated at a depth of 23 m in argillite within the Eleana Formation on the Nevada Test Site (NTS). The test geometrically simulated emplacement of a single canister of High-Level Waste (HLW) and was operated at a power level of 2.5 kW for 21 days, followed by 3.8 kW to 250 days, when the power was turned off. Below 85 to 100{sup 0}C, there was good agreement between modeled and measured thermal results in the rock and in the emplacement hole, except for transient transport of water in the heater hole. Above 100{sup 0}C, modeled and measured thermal results increasingly diverged, indicating that the in-situ rock-mass thermal conductivity decreased as a result of dehydration more than expected on the basis of matrix properties. Correlation of thermomechanical modeling and field results suggests that this decrease was caused by strong coupling of thermal and mechanical behavior of the argillite at elevated temperatures. No hole-wall decrepitation was observed in the experiment; this fact and the codrrelation of modeled and measured results at lower temperatures indicate that there is no a priori reason to eliminate argillaceous rocks from further consideration as a host rock for nuclear wastes.

Lappin, A R; Thomas, R K; McVey, D F

1981-04-01T23:59:59.000Z

306

Advanced refinery process heater. Annual report, October 1983-September 1984  

SciTech Connect

Activity during the first year of this project has focused on the conceptual design of the prototype heater and on the development of a custom-designed Pyrocore ceramic fiber burner for the heater. Three different concepts for the prototype heater have been produced, one of them modeled after a vertical cylindrical design and the other two resembling box-type heaters. All three concepts take advantage of the Pyrocore burner's flameless characteristic to make the heater more compact. Concerning the development of the burners, two different geometries were considered. Subscale prototypes of each type of burner were fabricated and tested. The more successful burners used actively-cooled edges to maintain the integrity of the gas-tight seals. Work on this project in the second year will include the design and fabrication of the 10 MMBtu/hr prototype heater, using the most feasible heater and burner designs developed during the first year.

Schreiber, R.J.; Gotterba, J.A.; Minden, A.C.

1984-10-01T23:59:59.000Z

307

Lid heater for glass melter  

DOE Patents (OSTI)

A glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes.

Phillips, Terrance D. (617 Chestnut Ct., Aiken, SC 29803)

1993-01-01T23:59:59.000Z

308

Cryostat including heater to heat a target  

DOE Patents (OSTI)

A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vessel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism. 2 figs.

Pehl, R.H.; Madden, N.W.; Malone, D.F.

1990-09-11T23:59:59.000Z

309

Enhanced heat transfer tubes for film absorbers of absorption chiller/heater  

SciTech Connect

Absorption chiller/heaters using non-CFC refrigerants are attracting attention as environmentally friendly energy systems. As the refrigerant/absorbent pair, the water/lithium bromide aqueous solution pair is preferably used for most absorption chiller/heaters in Japan. Absorption chiller/heaters, mainly used as water chillers and air-conditioners, are commercially available at least for unit cooling capacities above 60 kW. In absorption chiller/heaters, the absorber must be made compact, because the absorber has the largest heat transfer area of the four primary heat exchangers in the system: the evaporator, absorber, regenerator and condenser. Although a great amount of information is available on the evaporator and condenser, the same type of information concerning the absorber is lacking. This paper introduces two kinds of double fluted tubes called Arm tubs and Floral tubes for film absorbers. Arm tubes are manufactured using a two-pass drawbench process, while Floral tubes are made using a single pass drawbench process. The experiments using a lithium bromide aqueous solution with the addition of 250 ppm n-octyl alcohol as the surfactant showed that Arm tubes and Floral tubes had about 40% higher heat transfer performance than plain tubes. Therefore, Floral tubes are expected to realize a high performance at low cost. Furthermore, the optimization of the number of grooves on the outside of the tubes is also described here.

Sasaki, Naoe; Nosetani, Tadashi [Sumitomo Light Metal Industry, Ltd., Nagoya, Aichi (Japan); Furukawa, Masahiro; Kaneko, Toshiyuki [Sanyo Electric Co., Ltd., Ora, Gunma (Japan). Commercial Air-Conditioning Div.

1995-12-31T23:59:59.000Z

310

Highly Insulating Windows - Cost  

NLE Websites -- All DOE Office Websites (Extended Search)

Cost Cost The following is an estimate of the cost effective incremental cost of highly-insulating windows (U-factor=0.20 Btu/hr-ft2-F) compared to regular ENERGY STAR windows (U-factor 0.35 Btu/hr-ft2-F). Energy savings from lower U-factors were simulated with RESFEN over an assumed useful window life of 25 years. To determine the maximum incremental cost at which highly-insulating windows would still be cost-effective, we used a formula used by many utility companies to calculate the cost of saved energy from energy efficiency programs, based on the programs' cost and savings. We turned this formula around so that the cost of saved energy equals the present energy prices in the studied locations, whereas the program cost (the incremental cost of the windows) is the dependent variable. By entering 5%

311

Plasma window characterization  

SciTech Connect

Parameters of an arc Ar plasma discharge used as a plasma window with a discharge current of {approx}50 A and a voltage of {approx}58 V are presented. It is shown that this arc discharge allows one to decrease the pressure at the low pressure end of the plasma window almost 380 times using relatively low pumping at the low pressure end of the plasma window. Calculations of the plasma parameters and their spatial distribution using a simple wall-stabilized arc model showed a satisfactory agreement with the experimentally obtained data. It is shown that a significant decrease in gas flow through the plasma window occurs due to the increase in plasma viscosity. An improvement of the plasma window ignition and some of its design aspects are described as well.

Krasik, Ya. E.; Gleizer, S.; Gurovich, V.; Kronhaus, I.; Hershcovitch, A.; Nozar, P.; Taliani, C. [Physics Department, Technion, 32000 Haifa (Israel); Brookhaven National Laboratory, New York 11973-5000 (United States); Istituto per lo Studio dei Materiali Nanostrutturati, 40 129 Bologna (Italy)

2007-03-01T23:59:59.000Z

312

Window Types | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Window Types Window Types Window Types June 18, 2012 - 8:06am Addthis A wood-frame window with insulated window glazing. | Photo courtesy of ©iStockphoto/chandlerphoto A wood-frame window with insulated window glazing. | Photo courtesy of ©iStockphoto/chandlerphoto What does this mean for me? If you have old windows, they are likely losing large amounts of energy through the frames and glazing. By upgrading old windows, you can reduce heating and cooling costs in your home. Windows come in a number of different frame and glazing types. By combining an energy-efficient frame choice with a glazing type tailored to your climate and application, you can customize each of your home's windows. Types of Window Frames Improving the thermal resistance of the frame can contribute to a window's

313

Window Types | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Window Types Window Types Window Types June 18, 2012 - 8:06am Addthis A wood-frame window with insulated window glazing. | Photo courtesy of ©iStockphoto/chandlerphoto A wood-frame window with insulated window glazing. | Photo courtesy of ©iStockphoto/chandlerphoto What does this mean for me? If you have old windows, they are likely losing large amounts of energy through the frames and glazing. By upgrading old windows, you can reduce heating and cooling costs in your home. Windows come in a number of different frame and glazing types. By combining an energy-efficient frame choice with a glazing type tailored to your climate and application, you can customize each of your home's windows. Types of Window Frames Improving the thermal resistance of the frame can contribute to a window's

314

Building Technologies Office: Open-Standard Wireless Controllers for Water  

NLE Websites -- All DOE Office Websites (Extended Search)

Open-Standard Wireless Open-Standard Wireless Controllers for Water Heaters Research Project to someone by E-mail Share Building Technologies Office: Open-Standard Wireless Controllers for Water Heaters Research Project on Facebook Tweet about Building Technologies Office: Open-Standard Wireless Controllers for Water Heaters Research Project on Twitter Bookmark Building Technologies Office: Open-Standard Wireless Controllers for Water Heaters Research Project on Google Bookmark Building Technologies Office: Open-Standard Wireless Controllers for Water Heaters Research Project on Delicious Rank Building Technologies Office: Open-Standard Wireless Controllers for Water Heaters Research Project on Digg Find More places to share Building Technologies Office: Open-Standard Wireless Controllers for Water Heaters Research Project on

315

Field Evaluation of Windows  

NLE Websites -- All DOE Office Websites (Extended Search)

Evaluation of Windows Evaluation of Windows Last Updated: 10/20/2009 Various tools can be used to evaluate windows in the field. Unless a new window still has the NFRC label attached to it, it is nearly impossible to determine by sight what the thermal and optical performance of a window is. These tools can provide information, such as low-e coating, gap width and gas fill, that can be used to approximate the performance of a window. Solar gain and Low-e detector This device can be used to determine if a low-e coating is present in the window, what type of coating it is, and where it is located. The type of low-e coating will indicate the amount of solar gain that is admitted through the coating. Readings can be "low", "medium" or "high". The device will also indicate on which glass surface the low-e coating is in relation to the position of the device. Limitations: Only works on glass of 1/8" (3 mm) or thinner. Cost: around $350 from EDTM.com

316

Tips: Windows | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Windows Windows Tips: Windows June 18, 2012 - 9:43am Addthis Tips: Windows Windows can be one of your home's most attractive features. Windows provide views, daylighting, ventilation, and heat from the sun in the winter. Unfortunately, they can also account for 10% to 25% of your heating bill by letting heat out. During the summer, your air conditioner must work harder to cool hot air from sunny windows. Install ENERGY STAR®-qualified windows and use curtains and shade to give your air conditioner and energy bill a break. If your home has single-pane windows, consider replacing them with double-pane windows with high-performance glass-low-e or spectrally selective coatings. In colder climates, select gas-filled windows with low-e coatings to reduce heat loss. In warmer climates, select windows with

317

Windows, Doors, & Skylights | Department of Energy  

Energy Savers (EERE)

Logan Architects. Windows affect home aesthetics as well as energy use. Window Types A wood-frame window with insulated window glazing. | Photo courtesy of iStockphoto...

318

Subject Responses to Electrochromic Windows  

E-Print Network (OSTI)

Visual quality assessment of electrochromic and conventionalissues for large-area electrochromic windows in commercialOffice worker preferences of electrochromic windows: a pilot

Clear, Robert; Inkarojrit, Vorapat; Lee, Eleanor

2006-01-01T23:59:59.000Z

319

Multi-step heater deployment in a subsurface formation  

DOE Patents (OSTI)

A method for installing a horizontal or inclined subsurface heater includes placing a heating section of a heater in a horizontal or inclined section of a wellbore with an installation tool. The tool is uncoupled from the heating section. A lead in section is mechanically and electrically coupled to the heating section of the heater. The lead-in section is located in an angled or vertical section of the wellbore.

Mason, Stanley Leroy (Allen, TX)

2012-04-03T23:59:59.000Z

320

Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration  

DOE Patents (OSTI)

A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

Vinegar, Harold J. (Bellaire, TX); Sandberg, Chester Ledlie (Palo Alto, CA)

2010-11-09T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

CH7 Windows Introduction  

E-Print Network (OSTI)

4 Server · Account lockout security ­ Protection contre les attaques sur les mots de passe Windows NT 4 Server · Account lockout security ­ Protection contre les attaques sur les mots de passe

Collette. Sébastien

322

Zero Energy Windows  

E-Print Network (OSTI)

estimates of the U-factor and SHGC for todays installedtoday's window stock U-factor and SHGC properties used thosepoint. U-factor and SHGC estimates vary by prototypical

Arasteh, Dariush; Selkowitz, Steve; Apte, Josh; LaFrance, Marc

2006-01-01T23:59:59.000Z

323

Seeing Windows Through  

NLE Websites -- All DOE Office Websites (Extended Search)

8 8 Seeing Windows Through A profusion of gases, glazings, and gap sizes are among the factors that confound efforts to measure the energy performance of a window or skylight. The increasing variety of efficiency-enhancing options for windows and their frames poses a formidable challenge to builders, utilities, code officials, and consumers. Fortunately, a new system for accurately rating and labeling these products promises to help demystify them and to foster nationwide improvements in energy efficiency. NFRC is Born Window trade groups have historically organized around specific materials or components (such as glass or frames), and energy has rarely been their focal point. This changed in 1989 with the formation of the National Fenestration Rating Council. One impetus behind the industry's

324

Advanced refinery process heater. Final report, (October 1983-September 1988)  

SciTech Connect

A prototype refinery process heater was designed, built and successfully tested, demonstrating the improvements available to heater design through the use of Zone-Controlled Pyrocore radiant gas burners. The 10 MMBtu/hr rated heater released 17 ppm NOx (corrected to 3% oxygen) under full load operation, the lowest NOx emissions technically and commercially achieved in this type of equipment without the use of post-combustion flue-gas processing. Operating with 400F combustion air preheat and a 500F process fluid outlet temperature, the heater achieved overall thermal efficiencies of 92.8% on a LHV basis due in part to the significantly improved performance of the radiant heat exchange section. The radiant burners used in the heater have been proven in performance and reliability, and have also been shown to be applicable to both new heater designs and retrofits into existing heaters. The improved radiant performance of the heater and the use of 'flameless' radiant burners eliminates tube burn-out failures in both the radiant and convective tube coils, further improving the reliability of equipment based on this design. Three separate U.S. Patents have been issued covering the heater design and the use of Zone-Controlled Pyrocore burners in this application.

Minden, A.C.; Buckley, G.G.

1989-04-01T23:59:59.000Z

325

Window Daylighting Demo  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Window Daylighting Demo: Window Daylighting Demo: Accelerated Deployment of Daylighting and Shading Systems Stephen Selkowitz Lawrence Berkeley National Laboratory seselkowitz@lbl.gov 510-486-5064 April 4, 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: * Façade has large energy impacts. Cooling and lighting average ~ 40% of energy use in commercial buildings and often >50% in peak electric demand. * Many glazing/shading/daylighting options exist, but selecting the "best" solution is

326

Window Daylighting Demo  

NLE Websites -- All DOE Office Websites (Extended Search)

Window Daylighting Demo: Window Daylighting Demo: Accelerated Deployment of Daylighting and Shading Systems Stephen Selkowitz Lawrence Berkeley National Laboratory seselkowitz@lbl.gov 510-486-5064 April 4, 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: * Façade has large energy impacts. Cooling and lighting average ~ 40% of energy use in commercial buildings and often >50% in peak electric demand. * Many glazing/shading/daylighting options exist, but selecting the "best" solution is

327

NREL and Industry Advance Low-Cost Solar Water Heating R&D (Fact...  

NLE Websites -- All DOE Office Websites (Extended Search)

and Rhotech develop cost-effective solar water heating prototype to rival natural gas water heaters. Water heating energy use represents the second largest energy demand for homes...

328

Slurry fired heater cold-flow modelling  

SciTech Connect

This report summarizes the experimental and theoretical work leading to the scale-up of the SRC-I Demonstration Plant slurry fired heater. The scale-up involved a theoretical model using empirical relations in the derivation, and employed variables such as flow conditions, liquid viscosity, and slug frequency. Such variables have been shown to affect the heat transfer characteristics ofthe system. The model assumes that, if all other variables remain constant, the heat transfer coefficient can be scaled up proportional to D/sup -2/3/ (D = inside diameter of the fired heater tube). All flow conditions, liquid viscosities, and pipe inclinations relevant to the demonstration plant have indicated a slug flow regime in the slurry fired heater. The annular and stratified flow regimes should be avoided to minimize the potential for excessive pipe erosion and to decrease temperature gradients along the pipe cross section leading to coking and thermal stresses, respectively. Cold-flow studies in 3- and 6.75-in.-inside-diameter (ID) pipes were conducted to determine the effect of scale-up on flow regime, slug frequency, and slug dimensions. The developed model assumes that conduction heat transfer occurs through the liquid film surrounding the gas slug and laminar convective heat transfer to the liquid slug. A weighted average of these two heat transfer mechanisms gives a value for the average pipe heat transfer coefficient. The cold-flow work showed a decrease in the observed slug frequency between the 3- and 6.75-ID pipes. Data on the ratio of gas to liquid slug length in the 6.75-in. pipe are not yet complete, but are expected to yield generally lower values than those obtained in the 3-in. pipe; this will probably affect the scale-up to demonstration plant conditions. 5 references, 15 figures, 7 tables.

Moujaes, S.F.

1983-07-01T23:59:59.000Z

329

High Performance Window Retrofit  

SciTech Connect

The US Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and Traco partnered to develop high-performance windows for commercial building that are cost-effective. The main performance requirement for these windows was that they needed to have an R-value of at least 5 ft2 F h/Btu. This project seeks to quantify the potential energy savings from installing these windows in commercial buildings that are at least 20 years old. To this end, we are conducting evaluations at a two-story test facility that is representative of a commercial building from the 1980s, and are gathering measurements on the performance of its windows before and after double-pane, clear-glazed units are upgraded with R5 windows. Additionally, we will use these data to calibrate EnergyPlus models that we will allow us to extrapolate results to other climates. Findings from this project will provide empirical data on the benefits from high-performance windows, which will help promote their adoption in new and existing commercial buildings. This report describes the experimental setup, and includes some of the field and simulation results.

Shrestha, Som S [ORNL] [ORNL; Hun, Diana E [ORNL] [ORNL; Desjarlais, Andre Omer [ORNL] [ORNL

2013-12-01T23:59:59.000Z

330

Storm Windows | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storm Windows Storm Windows Storm Windows June 18, 2012 - 8:20am Addthis An energy upgrade on this daycare center included interior storm windows because most of the windows are on the north elevation. | Photo courtesy of Larry Kinney, Synergistic Building Technologies. An energy upgrade on this daycare center included interior storm windows because most of the windows are on the north elevation. | Photo courtesy of Larry Kinney, Synergistic Building Technologies. Interior storm windows improved the energy efficiency of a daycare center with windows on the north elevation. | Photo courtesy of Larry Kinney, Synergistic Building Technologies. Interior storm windows improved the energy efficiency of a daycare center with windows on the north elevation. | Photo courtesy of Larry Kinney,

331

Storm Windows | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storm Windows Storm Windows Storm Windows June 18, 2012 - 8:20am Addthis An energy upgrade on this daycare center included interior storm windows because most of the windows are on the north elevation. | Photo courtesy of Larry Kinney, Synergistic Building Technologies. An energy upgrade on this daycare center included interior storm windows because most of the windows are on the north elevation. | Photo courtesy of Larry Kinney, Synergistic Building Technologies. Interior storm windows improved the energy efficiency of a daycare center with windows on the north elevation. | Photo courtesy of Larry Kinney, Synergistic Building Technologies. Interior storm windows improved the energy efficiency of a daycare center with windows on the north elevation. | Photo courtesy of Larry Kinney,

332

Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water Heaters Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water Heaters June 14, 2012 - 7:38pm Addthis A water heater's energy efficiency is determined by the energy factor (EF), which is based on the amount of hot water produced per unit of fuel consumed over a typical day. The higher the energy factor, the more efficient the water heater. A water heater's energy efficiency is determined by the energy factor (EF), which is based on the amount of hot water produced per unit of fuel consumed over a typical day. The higher the energy factor, the more efficient the water heater. What does this mean for me? Estimate the annual operating costs and compare several water heaters to determine whether it is worth investing in a more efficient

333

Highly Insulating Windows - Fram  

NLE Websites -- All DOE Office Websites (Extended Search)

Frames Frames Research performed at the Norwegian University of Science and Technology and LBNL has identified various highly insulating frame solutions. A report was released in 2007 describing some of these frames. This document reports the findings of a market and research review related to state-of-the-art highly insulating window frames. The market review focuses on window frames that satisfy the Passivhaus requirements (window U-value less or equal to 0.8 W/m2K ), while other examples are also given in order to show the variety of materials and solutions that may be used for constructing window frames with a low thermal transmittance (U-value). The market search shows that several combinations of materials are used in order to obtain window frames with a low U-value. The most common insulating material seems to be Polyurethane (PUR), which is used together with most of the common structural materials such as wood, aluminum, and PVC.

334

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Vacuum Glazing Modeling Vacuum Glazing Modeling It is now possible to model vacuum glazing in WINDOW 7. The first step is to define a new vacuum "gap" in the "Gap Library" (formerly the Gas Library). Then that vacuum gap is used in a glazing system to calculate the thermal characteristics of the glazing system with a vacuum gap. Gap Library The Gas Library has been renamed the Gap Library. To define a vacuum gap, check the "Vacuum" checkbox (this is only available for single gases, not gas mixtures). When this box is checked, new input variables will appear, including the vacuum pressure, the specific heat ratio and molecular weight of the vacuum gas. It is also necessary to define a pillar system for the vacuum gap. Pillar Definition Double click the double arrow to the right of the Pillar Definition pulldown to define a new pillar system. Define the shape and dimensions of the pillar system.

335

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 (7.2.29 -- December 29 2013) Release Notes Updated: 12/29/13 If you find bugs, or have comments about this version, please do not hesitate to send an email to WINDOWHelp@lbl.gov to report your findings. Getting feedback from users is how we improve the program. WINDOW 7.2.29 (December 29, 2013) Program Changes Glazing System Shading System Details For shading system in a Glazing System Library construction, the emittances, conductance and TIR are not displayed, as they are only available after a calculation has been completed. Perforated Screens An input value for "Effective Openness Factor" has been added to the Shading Layer Library for perforated screens. At a future date, we will update the program to calculate this value automatically.

336

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Deflection Modeling Deflection Modeling It is now possible to model the effects of glass deflection in WINDOW 7. Glazing System Library The Glazing System Library is where the deflection modeling input values are entered. When the "Model Deflection" box is checked, a Deflection input box appears. When the Glazing System is calculated, two rows of results, one for the undeflected state and one for the deflected state, appear for Center of Glass Results, Temperature Data and Angular data. In addition, a Deflection tab appears, which shows the deflection of each glass layer and the resulting gap width for each gap. Glazing System Deflect Input There are two options for defining the deflection in a glazing system, by choosing from the "Input" pulldown list:

337

Risk Factors for Contamination of Hotel Water Distribution Systems by Legionella Species  

Science Journals Connector (OSTI)

...period. DISCUSSION Our data indicate that at the time...www.ewgli.org/data/data_tables/year_onset...rates were higher than in big towns, where hotels generally...heaters powered directly by electricity and solar water heaters...

Varvara Mouchtouri; Emmanuel Velonakis; Andreas Tsakalof; Christina Kapoula; Georgia Goutziana; Alkiviadis Vatopoulos; Jenny Kremastinou; Christos Hadjichristodoulou

2007-01-19T23:59:59.000Z

338

Residential Windows and Window Coverings: A Detailed View of the Installed Base and User Behavior  

Energy.gov (U.S. Department of Energy (DOE))

Includes information about the installed base of residential windows and window coverings, and the operation of window coverings by households.

339

Solar Water Heating  

NLE Websites -- All DOE Office Websites (Extended Search)

publication provides basic informa- publication provides basic informa- tion on the components and types of solar water heaters currently available and the economic and environmental benefits of owning a system. Although the publica- tion does not provide information on building and installing your own system, it should help you discuss solar water heating systems intelligently with a solar equipment dealer. Solar water heaters, sometimes called

340

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network (OSTI)

stayed constant. Total Energy Use Global Warming Potential1. Total Energy Use: Northern California Global Warming2. Total Energy Use: Southern California Global Warming

Lu, Alison

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Advancement of Electrochromic Windows  

E-Print Network (OSTI)

heat gain coefficient (SHGC) range of 0.420.09. Findingslow-e windows (Tv=0.42, SHGC=0.22) to serve as a referencewall for glare (Tv =0.05, SHGC=0.09) reduced average daily

2006-01-01T23:59:59.000Z

342

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Welcome to the Efficient Windows Collaborative Welcome to the Efficient Windows Collaborative YOUR GATEWAY TO INFORMATION ON HOW TO CHOOSE ENERGY-EFFICIENT RESIDENTIAL WINDOWS 101 Efficient Windows Collaborative (EWC) members have made a commitment to manufacture and promote energy-efficient windows. This site provides unbiased information on the benefits of energy-efficient windows, descriptions of how they work, and recommendations for their selection and use. Selecting Windows for New Construction Window Selection Tool Selection Process Design Guidance Installation Selecting Replacement Windows Window Selection Tool Assessing Replacement Options Selection Process Design Guidance Installation Understanding Windows Benefits of Energy Efficient Windows Design Considerations How to Measure Performance Window Technologies

343

LBNL Windows & Daylighting Software -- WINDOW Documentation  

NLE Websites -- All DOE Office Websites (Extended Search)

Release Notes Release Notes Updated: 11/07/11 History of COMFEN 3.1 Releases New Features Glazed Wall Assembly In addition to modeling individual windows, COMFEN now has the capability of modeling "Glazed Wall Assemblies" which allow you to specify the number of horizontal and vertical framing members, as well as their spacing, and the program automatically generates the facade. Click here for more details. Material Library COMFEN now has a Material Library, which can be used in the Wall Construction and Spandrel Libraries. See the User Manual for more details. Wall Library COMFEN now has a Wall Library which can be used to build up layers from the Material Library to define a wall. See the User Manual for more details. Spandrel Library COMFEN now has a Spandrel Library which can be used to build up layers from the Material Library to define a spandrel, including glass and glazing systems as the outer-most layers. See the User Manual for more details.

344

Energy Savings from Window Attachments  

Energy.gov (U.S. Department of Energy (DOE))

This study presents energy-modeling results for a large number of window combinations with window attachments in typical residential buildings and in varied climates throughout the United States.

345

The Window Strategy with Options  

E-Print Network (OSTI)

The window strategy is one of several marketing strategies using futures and options to establish a floor price and allow for upside price potential. It also reduces option premium costs. This publication discusses how the window strategy works...

McCorkle, Dean; Amosson, Stephen H.; Fausett, Marvin

1999-06-23T23:59:59.000Z

346

Nanolens Window Coatings for Daylighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Nanolens Window Coatings for Nanolens Window Coatings for Daylighting Kyle J. Alvine Pacific Northwest National Laboratory Kyle.alvine@pnnl.gov / (509) - 372 - 4475 April 4 th , 2013 Demonstration of the effect To develop a novel, low-cost window coating to double daylight penetration to offset lighting energy use 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: PNNL is developing a novel, low-cost window coating to redirect daylight deeper into buildings to significantly offset lighting energy.

347

Nanolens Window Coatings for Daylighting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nanolens Window Coatings for Nanolens Window Coatings for Daylighting Kyle J. Alvine Pacific Northwest National Laboratory Kyle.alvine@pnnl.gov / (509) - 372 - 4475 April 4 th , 2013 Demonstration of the effect To develop a novel, low-cost window coating to double daylight penetration to offset lighting energy use 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: PNNL is developing a novel, low-cost window coating to redirect daylight deeper into buildings to significantly offset lighting energy.

348

Windows Bitmap .bmp or .dib  

E-Print Network (OSTI)

platforms' GDI subsystem, where the specific format used is the Windows and OS/2 bitmap file format, usually

Gribaudo, Marco

349

THERMAL PERFORMANCE OF INSULATING WINDOW SYSTEMS  

E-Print Network (OSTI)

these windows incorporating hear mirror films are staticS. , "Thin Film Coatings for Energy Efficient Windows", LBLglazed windows with single and double plastic film inserts

Selkowitz, Stephen E.

2011-01-01T23:59:59.000Z

350

AN ENERGY EFFICIENT WINDOW SYSTEM FINAL REPORT.  

E-Print Network (OSTI)

for a variety of glass window films and so provides thetesting metallized mylar window films. They involve exposingconsumers to install window film products. The rigid sheet

Authors, Various

2011-01-01T23:59:59.000Z

351

Performance Criteria for Residential Zero Energy Windows  

E-Print Network (OSTI)

neutral energy impact of windows (energy consumption of buildingneutral energy impact of windows (energy consumption of buildingneutral energy impact of windows (energy consumption of building

Arasteh, Dariush; Goudey, Howdy; Huang, Joe; Kohler, Christian; Mitchell, Robin

2006-01-01T23:59:59.000Z

352

A Review of Electrochromic Window Performance Factors  

E-Print Network (OSTI)

ratio of 0.30. The electrochromic windows were controlled toProceedings. A Review of Electrochromic Window Performanceand economic benefits of electrochromic smart windows,"

Selkowitz Ed, S.E.

2010-01-01T23:59:59.000Z

353

Windows, Doors, & Skylights | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Windows, Doors, & Skylights Windows, Doors, & Skylights Windows, Doors, & Skylights Windows affect home aesthetics as well as energy use. Learn more about energy-efficient windows. Windows affect home aesthetics as well as energy use. Learn more about energy-efficient windows. Energy-efficient windows, doors, and skylights-also known as fenestration-can help lower a home's heating, cooling, and lighting costs. Learn about the energy performance ratings to consider when selecting windows, doors, and skylights, and how to maximize their energy efficiency in your home. Featured Window Types A wood-frame window with insulated window glazing. | Photo courtesy of ©iStockphoto/chandlerphoto

354

21 - Life cycle assessment (LCA) of windows and window materials  

Science Journals Connector (OSTI)

Abstract: Windows are a significant component in sustainable buildings in both the impacts caused by their material life cycles and by their influence on the performance of a building over its service life. Life cycle assessment (LCA) studies have compared the impacts of different framing materials with mixed results. LCA has also been used to estimate the environmental payback of higher manufacturing impacts from producing better performing windows. Future sustainable window selection should make use of standardized LCA data for windows and utilize advanced technologies to optimize window performance.

J. Salazar

2014-01-01T23:59:59.000Z

355

Windows Forensic Analysis DVD Toolkit  

Science Journals Connector (OSTI)

The only book available on the market that addresses and discusses in-depth forensic analysis of Windows systems. Windows Forensic Analysis DVD Toolkit takes the reader to a whole new, undiscovered level of forensic analysis for Windows systems, providing ... Keywords: Computer Science, Security

Harlan Carvey

2007-04-01T23:59:59.000Z

356

Gibson Electric Membership Corporation - Residential Energy Efficient Water  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Gibson Electric Membership Corporation - Residential Energy Gibson Electric Membership Corporation - Residential Energy Efficient Water Heater Loan Program Gibson Electric Membership Corporation - Residential Energy Efficient Water Heater Loan Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Maximum Rebate No financing cap for water heater. Program Info State Tennessee Program Type Utility Loan Program Rebate Amount Electric-to-Electric Water Heater Installation: up to $100 Gas-to-Electric Energy Heater Installation: up to $175 Provider Gibson Electric Membership Corporation Gibson Electric Membership Corporation provides loans to its residential customers to finance new, energy efficient water heaters. The loans are interest-free and can be paid off in as many as 3 years. To participate,

357

Behavioral Perspectives on Home Energy Audits: The Role of Auditors, Labels, Reports, and Audit Tools on Homeowner Decision Making  

E-Print Network (OSTI)

efficiency windows Solar Panel Solar Water Heater Upgrade -? Solar panels Install photovoltaic Adding or maintaining solar panels Number of homes

Ingle, Aaron

2013-01-01T23:59:59.000Z

358

Space Heaters The University recognizes that individuals have different levels of comfort associated with  

E-Print Network (OSTI)

used must be currently UL (Underwriters Laboratory) approved. 4. Approved space heaters must be fan driven. Space heaters with heated coils are not permitted. 5. Space heaters must have a thermostat that shuts unit off when a certain temperature is reached. 6. Space heaters must have a tip-over shutdown

de Lijser, Peter

359

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer  

E-Print Network (OSTI)

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer Elise A with resistive heater-thermometers,10­13 there is a lack of published reports on the electrical noise silicon heater- thermometer cantilevers.12 However, a key difference is that doped silicon heater-thermometers

King, William P.

360

Heat Recovery Consideration for Process Heaters and Boilers  

E-Print Network (OSTI)

The largest single area for industrial energy conservation is in the improvement of combustion efficiencies for heaters and boilers. A number of methods can be employed to recover heat. The most common are by use of recuperative air preheaters...

Kumar, A.

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

An Analysis of Steam Process Heater Condensate Drainage Options  

E-Print Network (OSTI)

The production and reliability performance of Steam Process Heaters can be significantly affected by the condensate drainage design that is employed. There are currently a variety of drainage options which can be confusing to a system designer who...

Risko, J. R.

362

Ninety - Two Percent Minimum Heater Efficiency By 1980  

E-Print Network (OSTI)

Technology is now available to increase heater efficiencies to 92 percent and more. By 1980, this technology will be field proven and corrosion and reliability problems identified and resolved. Recent studies have shown that a minimum efficiency...

Mieth, H. C.; Hardie, J. E.

1980-01-01T23:59:59.000Z

363

Temperature limited heater utilizing non-ferromagnetic conductor  

DOE Patents (OSTI)

A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

Vinegar; Harold J. (Bellaire, TX), Harris; Christopher Kelvin (Houston, TX)

2012-07-17T23:59:59.000Z

364

Atmospheric Pressure Deposition for Electrochromic Windows |...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Atmospheric Pressure Deposition for Electrochromic Windows Atmospheric Pressure Deposition for Electrochromic Windows Emerging Technologies Project for the 2013 Building...

365

Windows Retrofit Description and Photos Appendix E -Windows Retrofit Description and Photos  

E-Print Network (OSTI)

and roller to provide a water-tight seal to the drainage plane, as depicted in Figure E.3. #12;E.2 Figure E.2 was used to seal window in place. Reinstalled strip on inside and outside. Figure E.4. Peel-and-Stick Membrane Applied with Heat Gun, Roller, and Caulker at Seams for Air-Tight Installation Figure E.5

366

Sacramento Ordinance to Waive Fees for Solar Hot Water  

Energy.gov (U.S. Department of Energy (DOE))

An ordinance suspending for the calendar years 2007-2009 all fees related to installations of solar water heaters on existing residences.

367

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Window Technologies: Low Conductance Spacers Window Technologies: Low Conductance Spacers Spacers The lites of glass in an insulating unit must be held apart at the appropriate distance by spacers. In addition to keeping the glass lites separated, the spacer system must serve a number of functions: accommodate stress induced by thermal expansion and pressure differences; provide a moisture barrier that prevents passage of water or water vapor that would fog the unit; provide a gas-tight seal that prevents the loss of any special low-conductance gas in the air space; create an insulating barrier that reduces the formation of interior condensation at the edge. Spacers The standard solution for insulating glass units (IGUs) is the use of metal spacers and sealants. These spacers, typically aluminum, also

368

Savings Project: Lower Water Heating Temperature | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savings Project: Lower Water Heating Temperature Savings Project: Lower Water Heating Temperature Savings Project: Lower Water Heating Temperature Addthis Project Level Easy Energy Savings $12-$30 annually for each 10ºF reduction Time to Complete 2 hours Overall Cost $0 Turning down your water heater temperature can save energy and money. | Photo courtesy of iStockphoto.com/BanksPhotos Turning down your water heater temperature can save energy and money. | Photo courtesy of iStockphoto.com/BanksPhotos Although some manufacturers set water heater thermostats at 140ºF, most households usually only require them to be set at 120ºF, which also slows mineral buildup and corrosion in your water heater and pipes. Water heated at 140ºF also poses a safety hazard-scalding. Savings resulting from turning down your water heater temperature are based

369

Savings Project: Lower Water Heating Temperature | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lower Water Heating Temperature Lower Water Heating Temperature Savings Project: Lower Water Heating Temperature Addthis Project Level Easy Energy Savings $12-$30 annually for each 10ºF reduction Time to Complete 2 hours Overall Cost $0 Turning down your water heater temperature can save energy and money. | Photo courtesy of iStockphoto.com/BanksPhotos Turning down your water heater temperature can save energy and money. | Photo courtesy of iStockphoto.com/BanksPhotos Although some manufacturers set water heater thermostats at 140ºF, most households usually only require them to be set at 120ºF, which also slows mineral buildup and corrosion in your water heater and pipes. Water heated at 140ºF also poses a safety hazard-scalding. Savings resulting from turning down your water heater temperature are based

370

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Tools Tools Looking for windows for a new home? Use the Window Selection Tool to compare annual energy performance for windows in new construction. Window Selection Tool Looking for replacement windows? Use the Window Selection Tool to compare annual energy performance for replacement windows. Window Selection Tool Window Selection Tool Use the Window Selection Tool for new or replacement windows to compare the annual energy performance of different window types and design conditions for a typical house. Find manufacturers who offer windows and skylights within the generic results shown. Learn more about manufacturers' specific product options. Use the Window Selection Tool to: Compare how various window or skylight types affect estimated energy cost for a typical house in your location.

371

A Combined Water Heater, Dehumidifier, and Cooler (WHDC)  

Energy.gov (U.S. Department of Energy (DOE))

Lead Performer: University of Florida, Gainesville, FloridaPartners: -- Oak Ridge National Laboratory - Oak Ridge, TN -- Stony Brook University - Stony Brook, NY

372

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

into The Weatherization Assistance Program, May 2003. D&Rand DOEs weatherization assistance program (Kelso 2003),

Franco, Victor

2011-01-01T23:59:59.000Z

373

Covered Product Category: Commercial Gas Water Heaters | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

can be corrosive to certain materials. This acidic condensate does not affect the plastic piping typically used in new construction. However, acidic condensate can damage cast...

374

The use of solar water heaters in Mexico City.  

E-Print Network (OSTI)

??During the last decade, Mexico City's air quality has deteriorated dramatically. Air pollution management has become a major issue, and a number of policies and (more)

Ferrel-Mendieta, Minerva.

1999-01-01T23:59:59.000Z

375

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

and Renewable Energy (EERE). 1993. Technical SupportReport No. DOE/EE-0009. USDOE EERE. 2002. Technical Supportappliance_standards/ USDOE EERE. 2010. Final Rule Technical

Franco, Victor

2011-01-01T23:59:59.000Z

376

Heat Pump Water Heater Modeling in EnergyPlus (Presentation)  

SciTech Connect

This presentation summarizes NREL's development of a HPWH model for use in hourly building energy simulation programs, such as BEopt; this presentation was given at the Building America Stakeholder meeting on March 1, 2012, in Austin, Texas.

Wilson, E.; Christensen, C.

2012-03-01T23:59:59.000Z

377

Covered Product Category: Commercial Gas Water Heaters | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

gallons in capacity. The ENERGY STAR specification also includes commercial air source heat pump units, but no performance requirement has been set. Until ENERGY STAR sets a...

378

ENERGY STAR Residential Water Heaters to Save Americans Up to...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

program, formed in 1992 as a voluntary, market-based partnership that seeks to reduce air pollution through increased energy efficiency. DOE and EPA work to offer businesses...

379

WINDOW 5 Glass Library Update  

NLE Websites -- All DOE Office Websites (Extended Search)

WINDOW 6 or 7 Glass Library Update WINDOW 6 or 7 Glass Library Update Last update:12/09/13 07:26 PM Automatic IGDB Update Feature in WINDOW 6 and 7 The latest versions of WINDOW 6 and 7 have an automatic IGDB database update function in the Glass Library. When you first open the program, it checks to see if there is an IGDB version later than what you already have installed, and will notify you if there is an update. Then you can download and install the IGDB database, and click on the Update IGDB button in the Glass Library in order to start the automatic update. For older versions of WINDOW 6 and 7 without the automatic IGDB update function bullet How to Check the Current WINDOW5 IGDB Version bullet Updating the Glass Library bullet Problem Updating the Glass Library bullet Discontinued Records or Reused NFRC IDs

380

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Selection Process for Replacement Windows Selection Process for Replacement Windows What are the benefits of energy-efficient windows? Energy & Cost Savings Improved Comfort Less Condensation Increased Light & View Reduced Fading Lower HVAC Costs How is window performance measured? U-factor Solar Heat Gain Coefficient Visible Transmittance Air Leakage Condensation Resistance Are there financing and incentive programs? Overview of Utility and State Programs Building Codes Energy Rating Programs 1. Assess Your Existing Windows Assess whether your windows should be repaired, retrofitted, or replaced. While most new windows have labels indicating their energy properties, such information is not often available for existing windows. Download Window Energy Efficiency Checklist for assistance. Window Replacement

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Performance characteristics of solar air heater with surface mounted obstacles  

Science Journals Connector (OSTI)

Abstract The performance of conventional solar air heaters (SAHs) can be improved by providing obstacles on the heated wall (i.e. on the absorber plate). Experiments have been performed to collect heat transfer and flow-friction data from an air heater duct with delta-shaped obstacles mounted on the absorber surface and having an aspect ratio 6:1 resembling the conditions close to the solar air heaters. This study encompassed for the range of Reynolds number (Re) from 2100 to 30,000, relative obstacle height (e/H) from 0.25 to 0.75, relative obstacle longitudinal pitch (Pl/e) from 3/2 to 11/2, relative obstacle transverse pitch (Pt/b) from 1 to 7/3 and the angle of incidence (?) varied from 30 to 90. The thermo-hydraulic performance characteristics of SAH have been compared with the previous published works and the optimum range of the geometries have been explored for the better performance of such air-heaters compared to the other designs of solar air heaters.

Adisu Bekele; Manish Mishra; Sushanta Dutta

2014-01-01T23:59:59.000Z

382

Building America Top Innovations 2013 Profile … Window Replacement, Rehabilitation, & Repair Guide  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

are also discussed. are also discussed. Water infiltration is dealt with at considerable length because windows are one of the likeliest components in the building structure for water entry and because water intrusion and resultant damage may have gone on unnoticed for some time as water can enter the wall cavity through and around the window assembly. Suggestions for investigating sources of water intrusion are provided. The condition of the decorative trim around the window can be an indication of water damage but deterioration of the trim is typically an aesthetic problem not a performance problem. However, if the window sill is damaged, it should be replaced because it is the means by which water will drain out away from the house or, incorrectly, into the wall. Damaged or deteriorating window sashes, frames, or casings

383

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Replacement Windows for Existing Homes Homes Replacement Windows for Existing Homes Homes Window Selection Tool Use the Window Selection Tool for existing homes (replacement windows) to compare performance of 20 different window types in your location. The Window Selection Tool will take you through a series of design conditions pertaining to your design and location. It is a step-by-step decision-making tool to help determine the most energy efficient window for your house. Window Selection Tool Assessing Options This section provides guidance the options available to improve the performance of your existing windows or to replace them. You can assess whether to repair, retrofit or replace your existing windows. Window Selection Process This section provides step-by-step guidance on the window selection process for replacement windows including issues of code, energy, durability, and installation.

384

Feedback regulated induction heater for a flowing fluid  

DOE Patents (OSTI)

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable porportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005/sup 0/C at a flow rate of 50 cm/sup 3//sec with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, A.; Swift, G.W.

1984-06-13T23:59:59.000Z

385

Feedback regulated induction heater for a flowing fluid  

DOE Patents (OSTI)

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable proportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005.degree. C. at a flow rate of 50 cm.sup.3 /second with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, Albert (Santa Fe, NM); Swift, Gregory W. (Los Alamos, NM)

1985-01-01T23:59:59.000Z

386

A window on urban sustainability  

SciTech Connect

Sustainable urban development requires the integration of environmental interests in urban planning. Although various methods of environmental assessment have been developed, plan outcomes are often disappointing due to the complex nature of decision-making in urban planning, which takes place in multiple arenas within multiple policy networks involving diverse stakeholders. We argue that the concept of decision windows can structure this seemingly chaotic chain of interrelated decisions. First, explicitly considering the dynamics of the decision-making process, we further conceptualized decision windows as moments in an intricate web of substantively connected deliberative processes where issues are reframed within a decision-making arena, and interests may be linked within and across arenas. Adopting this perspective in two case studies, we then explored how decision windows arise, which factors determine their effectiveness and how their occurrence can be influenced so as to arrive at more sustainable solutions. We conclude that the integration of environmental interests in urban planning is highly dependent on the ability of the professionals involved to recognize and manipulate decision windows. Finally, we explore how decision windows may be opened. -- Highlights: Decision-making about sustainable urban development occurs in networks. The concept of decision windows was further elaborated. Decision windows help understand how environmental interests enter decision-making. Decision windows can, to some extent, be influenced.

Stigt, Rien van, E-mail: rien.vanstigt@hu.nl [Research Center for Technology and Innovation, Utrecht University of Applied Sciences, P.O. Box 182, 3500 AD Utrecht (Netherlands); Driessen, Peter P.J., E-mail: p.driessen@uu.nl [Copernicus Institute of Sustainable Development, Faculty of Geosciences, Utrecht University, P.O. Box 80.115, 3508 TC Utrecht (Netherlands); Spit, Tejo J.M., E-mail: T.J.M.Spit@uu.nl [Department of Human Geography and Spatial Planning, Faculty of Geosciences, Utrecht University, P.O. Box 80.115, 3508 TC Utrecht (Netherlands)

2013-09-15T23:59:59.000Z

387

Columbia Water and Light- Solar Rebates  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water and Light (CWL) offers rebates to its commercial and residential customers for the purchase of solar water heaters and solar photovoltaic systems. These rebates are available for...

388

Electric Blanket vs. Space Heater: #EnergyFaceoff Round 3 Heats...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up Electric Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up November 17, 2014 - 9:49am Q&A Which appliance do you...

389

Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three November 19, 2014...

390

Numerical analysis of thermal-hydrological conditions in the single heater test at Yucca Mountain  

E-Print Network (OSTI)

Single Heater Test at Yucca Mountain, LBNL-39789, E.O. LawSingle Heater Test at Yucca Mountain Jens T. Birkholzer andwaste repository at Yucca Mountain. The heating phase of the

Birkholzer, Jens T.; Tsang, Yvonne W.

1998-01-01T23:59:59.000Z

391

Silicon microbench heater elements for packaging opto-electronic devices  

SciTech Connect

Examples are presented of the application of Lawrence Livermore National Laboratory`s expertise in photonics packaging. Several examples of packaged devices will be described. Particular attention is given to silicon microbenches incorporating heaters and their use in semiconductor optical amplifier fiber pigtailing and packaging.

Combs, R.; Keiser, P.; Kleint, K.; Pocha, M.; Patterson, F.; Strand, O.T.

1995-09-01T23:59:59.000Z

392

Novel Column Heater for Fast Capillary Gas Chromatography  

Science Journals Connector (OSTI)

......expected advantage of radial heating with the coaxial heater...with other "coated" heating elements, differences...Louisiana light crude oil; 3 m 0.1 mm phenyl...expansion coefficient, and price imposed substantial practical...existing standard column heating technology. Thus, chromatographic......

E.U. Ehrmann; H.P. Dharmasena; K. Carney; E.B. Overton

1996-12-01T23:59:59.000Z

393

LBNL Window & Daylighting Software -- WINDOW 6 Research Version  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 Last Updated: 12/29/2013 If you find bugs, or have comments about this version, please do not hesitate to send an email to WINDOWHelp@lbl.gov to report your findings. Getting feedback from users is how we improve the program. WINDOW 7.2 (7.2.29) (12/29/2013) Release Notes -- Please read these before running this version ! This version contains these new modeling features Honeycomb shades Dynamic Glazing (Thermochromic and Electrochromic) This version is compatible with THERM 7.1 Please send us emails as you find issues in the program -- that is the only way that we can make it more robust. We hope to iterate versions fairly quickly in the next month or so to get the bugs ironed out. Radiance for WINDOW 7 Get a copy of Radiance for WINDOW 7.2 Must be used with WINDOW 7.0.59 or later

394

LBNL Windows & Daylighting Software -- WINDOW5: Knowledge Base  

NLE Websites -- All DOE Office Websites (Extended Search)

6.3 Knowledge Base 6.3 Knowledge Base Tip - use the Find function in your browser to search this page Last update:11/04/13 01:16 PM Download WINDOW 6.3 Send feedback via email to WindowHelp@lbl.gov. Also as bugs and comments are submitted by testers, the will be posted on this Knowledge Base, so check here for the latest information about the program. CONTENTS INSTALLATION KNOWN BUGS ** Operating Systems -- Microsoft Windows 7 and Vista ** Environmental Conditions -- Kimura convection model not working Locked Files with Install/De-install Environmental Conditions -- Fixed Combined Coefficient Bug Installation Problems Error Message during Calc due to decimal point of "," Minimum computer requirements Importing THERM file into WINDOW generates "Unnamed file has a bad format" error message

395

LBNL Window & Daylighting Software -- WINDOW 6 Research Version  

NLE Websites -- All DOE Office Websites (Extended Search)

7.0 7.0 Last Updated: 05/20/2013 EN 673 / ISO 10077 Using WINDOW 7 and THERM 7 for EN 673 / ISO 10077 Calculations If you are interested in using WINDOW and THERM for EN 673 / ISO 10077 calculations, we have added that option to WINDOW 7. The calculation is not fully automated in the program yet, so there are many steps and a spreadsheet for the final calculation. We are interested in feedback (email WINDOWHelp@lbl.gov) about the process and the results from anyone who tests this feature. CAUTION: Do not model shading systems with the EN 673 thermal model. The program will produce results but they will most likely not be correct. Download this zip file (EN673.zip) which contains the following: Description of how to use WINDOW 6 and THERM 6 for the EN 673 / ISO 10077 calculations (PDF file)

396

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Storm Windows Storm Windows Window Attachments For detailed information on storm windows and other window attachments, visit www.windowattachments.org exit disclaimer , a site supported by Lawrence Berkeley National Laboratory, Building Green, and the U.S. Department of Energy. DOE's Energy Savers You can improve the energy efficiency of existing windows by adding interior or exterior storm panels. Storm Window Panels exit disclaimer Storm windows can reduce the air leakage and improve the insulating value of existing windows. They can be installed on the interior or exterior side of windows, and can be mounted permanently or for seasonal use. Interior storm windows can be more easily installed and removed for ventilation or cleaning. Storm windows can reduce air leakage. However, it is important that humid

397

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Solar Control Window Film Solar Control Window Film Window Attachments For detailed information on storm windows and other window attachments, visit www.windowattachments.org exit disclaimer , a site supported by Lawrence Berkeley National Laboratory, Building Green, and the U.S. Department of Energy. DOE's Energy Savers You can improve the energy efficiency of existing windows by applying a film. High-Reflectivity Window Films exit disclaimer International Window Film Association For more information on window film, check the Window Film Information Center exit disclaimer . Solar control window film reduces solar heat gain by reflection and absorption. As they also block solar heat gain in winter months, these films are ideal for cooling-dominated climates. Window films can be tinted

398

Restoration of Refinery Heaters Using the Technique of Prefabricated Ceramic Fiber Lined Panels  

E-Print Network (OSTI)

Refinery heater fuel requirements often represent 50% of a units operating cost. A one percent change in the efficiency of a heater firing 100 MBtu/hr amounts to more than $25,000 per year. Heater efficiency is influenced by casing hot spots, air...

Sento, H. D.

1981-01-01T23:59:59.000Z

399

Electron gun with cylindrical window  

SciTech Connect

This paper describes a three-electrode electron gun with a foil window in the form of a cylinder 300 mm in diameter and 200 mm high. With an accelerating voltage of 140 kV in the pulse mode (10 usec at 2 Hz) with grid modulation, the current extracted from the foil is 5.5 A. The ratio of the window area to the mass of the gun (23.7 cm/sup 2//kg) is greater by a factor of 3-5 than that of similar guns with flat windows.

Grigorev, Y.V.; Stepanov, A.V.

1986-01-01T23:59:59.000Z

400

High-Efficiency Window Air Conditioners - Building America Top...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Window Air Conditioners - Building America Top Innovation This photo shows a window air conditioning unit in place in a window frame. Window air conditioners are inexpensive,...

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Solar Water Heating: What's Hot and What's Not  

E-Print Network (OSTI)

A handful of electric utilities in the United States now pay incentives to their customers to install solar water heaters or are developing programs to do so. The solar water heater incentives are part of a broader utility demand-side management...

Stein, J.

402

Windows and Building Envelope | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and market challenges in the windows and building envelope sector. Image: National Renewable Energy Laboratory Read more Insulation and Window Projects Named as Top Energy...

403

Three-phase heaters with common overburden sections for heating subsurface formations  

DOE Patents (OSTI)

A heating system for a subsurface formation is described. The heating system includes three substantially u-shaped heaters with first end portions of the heaters being electrically coupled to a single, three-phase wye transformer and second end portions of the heaters being electrically coupled to each other and/or to ground. The three heaters may enter the formation through a first common wellbore and exit the formation through a second common wellbore so that the magnetic fields of the three heaters at least partially cancel out in the common wellbores.

Vinegar, Harold J. (Bellaire, TX)

2012-02-14T23:59:59.000Z

404

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Window Technologies: Operator Types Window Technologies: Operator Types Window Sash Operation When you select a window, there are numerous operating types to consider. Traditional operable window types include the projected or hinged types such as casement, awning, and hopper, and the sliding types such as double- and single-hung and horizontal sliding. In addition, the window market includes fixed windows, storm windows, sliding and swinging patio doors, skylights and roof windows, and window systems that can be added to a house to create bay or bow windows, miniature greenhouses, or full sun rooms. Looking for information on skylights? More information on skylights, light tubes, and their installation can be found here. Casement Casement windows are hinged at the sides. Hinged windows such as casements generally have lower air leakage rates than sliding windows from the same manufacturer because the sash closes by pressing against the frame. Casement windows project outward, providing significantly better ventilation than sliders of equal size. Because the sash protrudes from the plane of the wall, it can be controlled to catch passing breezes, but screens must be placed on the interior side. Virtually the entire casement window area can be opened, while sliders are limited to less than half of the window area. Casement

405

Building America Top Innovations 2013 Profile … Window Replacement, Rehabilitation, & Repair Guide  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

such as working on scaffolding are also discussed. such as working on scaffolding are also discussed. Water infiltration is dealt with at considerable length because windows are one of the likeliest components in the building structure for water entry and because water intrusion and resultant damage may have gone on unnoticed for some time as water can enter the wall cavity through and around the window assembly. Suggestions for investigating sources of water intrusion are provided. The condition of the decorative trim around the window can be an indication of water damage but deterioration of the trim is typically an aesthetic problem not a performance problem. However, if the window sill is damaged, it should be replaced because it is the means by which water will drain out away from the house or,

406

Marietta Power and Water - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marietta Power and Water - Residential Energy Efficiency Rebate Marietta Power and Water - Residential Energy Efficiency Rebate Program Marietta Power and Water - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Maximum Rebate $500 Program Info State Georgia Program Type Utility Rebate Program Rebate Amount Heat Pump: $150 Water Heater: $250 Heat Pump and Water Heater: $500 Provider Marietta Power and Water Marietta Power and Water provides rebates for electric water heaters ($250) and electric and dual-fuel heat pumps ($150). If both a water heater and heat pump are installed simultaneously, a rebate of $500 is available. Electric and dual-fuel heat pumps may be installed in newly constructed

407

Feasibility of accompanying uncontrolled linear heater with solar system innatural gas pressure drop stations  

Science Journals Connector (OSTI)

Natural gas (NG) must be preheated before pressure reduction takes places at City Gate Stations (CGS). Indirect Water Bath Gas Heaters are employed in the CGS for preheating. The heaters consume a considerable amount of NG for preheating. As low temperature is required, a solar system has been proposed to provide part of heat demand. The system consists of a collector array and a storage tank. The tank stores solar heat during the day and releases it during the night. To show the capabilities of the proposed system, the Akand CGS has been chosen as a case study. The results show that as the number of collector increases, the fuel cost decreases but the capital cost increases. An optimum number of collectors and the storage tank capacity have been found based on economic analysis. The fuel saving occurs throughout the year with the maximum at June. The economic feasibility study of the proposed system has been carried out using two methods. These methods are Simple Payback Ratio (SPR) and (Net Present Value) NPV. The first one unveils that the payback ratio is only 6.9 years. The NPV method shows that the system will give net benefit after 11 years.

M. Farzaneh-Gord; A. Arabkoohsar; M. Deymi Dasht-bayaz; V. Farzaneh-Kord

2012-01-01T23:59:59.000Z

408

CMU-ITC-86-045 , Windowing  

E-Print Network (OSTI)

on window-manager style graphics systems using the Tek termi- nals, inspired by some film Alan Kay showedCMU-ITC-86-045 , Windowing Systems , Implementations #12;#12;Window System Implementations Denver ABSTRACT Notes for a course given at the 1986 Winter Usenix meeting in Denver, CO. It covers window systems

409

Impacts of Water Quality on Residential Water Heating Equipment  

SciTech Connect

Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

Widder, Sarah H.; Baechler, Michael C.

2013-11-01T23:59:59.000Z

410

U. K. consortium Stirling engine regenerator effectiveness and heater performance  

SciTech Connect

This paper covers results of measurements of effectiveness of regenerator materials by use of a dynamic test rig. The rig enables measurements to be made of enthalpy flux through the regenerator under simulated Stirling engine conditions of fluid flow and heat transfer. The paper also discusses the design and operation of the 60 kw heat-pipe heater head of the U.K. Consortium Stirling engine.

Rice, G.; Dadd, M.W.; Jones, J.D.; Thonger, J.

1983-08-01T23:59:59.000Z

411

Chiller-heater unit nets building 2-yr payback  

SciTech Connect

A 500-ton double-absorption Hitachi Paraflow chiller-heater that switches from purchased steam to natural gas will reduce a Manhattan office building's energy costs by 55% and achieve a two-year payback. The new system replaces a steam-powered, single-stage absorption chiller. By reusing heat in a second-stage generator, the Hitachi unit uses only half as many Btus per ton as a conventional chiller. (DCK)

Duffy, J.

1983-05-09T23:59:59.000Z

412

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Understanding Windows Understanding Windows Benefits of Energy Efficient Windows The purpose for windows is to provide natural light, natural ventilation, and views to the outside. The benefits of high performance windows allows for Energy & Cost Savings, Improved Comfort, Less Condensation, Increased Light & View, Reduced Fading, and Lower HVAC Costs. Benefits of Energy Efficient Windows Design Considerations Windows are a complex and interesting element in residential design. New window products and technologies have changed the performance of windows in a radical way. Issues such as climate, orientation, shading, and window area all effect the energy performance, but human factor issues such as access to fresh air, daylight, and natural views impact the comfort of a home.

413

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Measuring Performance: Air Leakage (AL) Measuring Performance: Air Leakage (AL) Is my window leaking air? The Air Leakage (AL) rating pertains to leakage through the window assembly itself. Air infiltration can also occur around the frame of the window due to poor installation or poor maintenance of existing window systems. Make sure windows are properly installed and maintained (caulking and weatherstripping). Cold glass can create uncomfortable drafts as air next to the window is cooled and drops to the floor. This is not a result of air leaking through or around the window assembly but from a convective loop created when next to a window is cooled and drops to the floor. This air movement can be avoided by installing high-performance windows. Heat loss and gain occur by infiltration through cracks in the window

414

Materials performance in fluidized-bed air heaters  

SciTech Connect

Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock & Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

Natesan, K.; Podolski, W.

1991-12-01T23:59:59.000Z

415

Materials performance in fluidized-bed air heaters  

SciTech Connect

Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

Natesan, K.; Podolski, W.

1991-12-01T23:59:59.000Z

416

Energy Savings from Window Attachments  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

from from Window Attachments October 2013 Prepared for: Building Technologies Office Office of Energy Efficiency and Renewable Energy U.S. Department of Energy Prepared by: Lawrence Berkeley National Laboratory October 2013 Prepared for: Building Technologies Office Office of Energy Efficiency and Renewable Energy U.S. Department of Energy Prepared By: Lawrence Berkeley National Laboratory One Cyclotron Road, MS 90R3111 Berkeley, CA 94720 Authors: D. Charlie Curcija Mehry Yazdanian Christian Kohler Robert Hart Robin Mitchell Simon Vidanovic 1 ENERGY SAVINGS FROM WINDOW ATTACHMENTS TABLE OF CONTENTS: TABLE OF CONTENTS:................................................................................................... 1 1. EXECUTIVE SUMMARY ......................................................................................... 3

417

Energy Savings from Window Attachments  

NLE Websites -- All DOE Office Websites (Extended Search)

from from Window Attachments October 2013 Prepared for: Building Technologies Office Office of Energy Efficiency and Renewable Energy U.S. Department of Energy Prepared by: Lawrence Berkeley National Laboratory October 2013 Prepared for: Building Technologies Office Office of Energy Efficiency and Renewable Energy U.S. Department of Energy Prepared By: Lawrence Berkeley National Laboratory One Cyclotron Road, MS 90R3111 Berkeley, CA 94720 Authors: D. Charlie Curcija Mehry Yazdanian Christian Kohler Robert Hart Robin Mitchell Simon Vidanovic 1 ENERGY SAVINGS FROM WINDOW ATTACHMENTS TABLE OF CONTENTS: TABLE OF CONTENTS:................................................................................................... 1 1. EXECUTIVE SUMMARY ......................................................................................... 3

418

Secondary condenser Cooling water  

E-Print Network (OSTI)

Receiver Secondary condenser LC LC Reboiler TC PC Cooling water PC FCPC Condenser LC XC Throttling valve ¨ mx my l© ª y s § y m «¬ ly my wx l n® ® x np © ¯ Condenser Column Compressor Receiver Super-heater Decanter Secondary condenser Reboiler Throttling valve Expansion valve Cooling water

Skogestad, Sigurd

419

Building America Webinar: Central Multifamily Water Heating Systems  

Energy.gov (U.S. Department of Energy (DOE))

Hosted by DOE's Building America program, this webinar will focus on the effective use of central heat pump water heaters (HPWHs) and control systems to reduce the energy use in hot water distribution.

420

Save on Home Water Heating | Department of Energy  

Office of Environmental Management (EM)

and money, or choose an on-demand hot water heater to save even more. Tips: Water Heating Solar energy systems are among the renewable and efficiency purchases that are...

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Benefits of Efficient Windows Benefits of Efficient Windows Looking for information on windows for a new house? Window Selection Tool Selection Process Design Guidance Installation Looking for information on replacement windows? Window Selection Tool Assessing Options Selection Process Design Guidance Installation Energy & Cost Savings Energy efficient windows can substantially reduce the costs associated with heating and cooling. This section on Energy & Cost Savings illustrates these savings in both heating and cooling climates. Energy Savings Lower HVAC Costs High-performance windows not only provide reduced annual heating and cooling bills, they also reduce the peak heating and cooling loads. This section on Lower HVAC Cost illustrates how the use of high performance windows can help in reducing HVAC equipment sizing.

422

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Assessing Window Replacement Options Assessing Window Replacement Options What are the benefits of energy-efficient windows? Energy & Cost Savings Improved Comfort Less Condensation Increased Light & View Reduced Fading Lower HVAC Costs How is window performance measured? U-factor Solar Heat Gain Coefficient Visible Transmittance Air Leakage Condensation Resistance Are there financing and incentive programs? Overview of Utility and State Programs Performance Standards Energy Rating Programs Building America Program Documents Measure Guideline: Energy-Efficient Window Performance and Selection exit disclaimer Measure Guideline: Wood Window Repair, Rehabilitation, and Replacement exit disclaimer Whether you would like to improve the energy performance of your existing windows or replace them with new energy-efficient windows, several options are available. An energy audit can help you identify good strategies for more efficient windows and a more efficient house. Whichever energy efficiency measures you consider, the federal government as well as state, local, and utility programs may offer financing help or weatherization assistance.

423

3.4 Timeline Zoomable Window  

NLE Websites -- All DOE Office Websites (Extended Search)

.1 Zoomable and Scrollable Up: 3. Graphical User Interface .1 Zoomable and Scrollable Up: 3. Graphical User Interface Previous: 3.3 Legend Window Contents 3.4 Timeline Zoomable Window Figure 3.10: Initial display of the Timeline window of a 514 MB 16-process slog2 file with default preview resolution. Image timeline_popup Most of the advanced features in the SLOG-2 viewer are provided through a zoomable window. Jumpshot-4 has two zoomable windows: Timeline and Histogram. Figure 3.10 is the initial display of the Timeline window of a half-gigabyte 16-timeline slog2 file. The zoomable window consists of several concealable and removable components. In the center of the window is the zoomable and scrollable canvas. For the Timeline window, the center canvas is called the timeline canvas. Directly on top of the zoomable

424

Energy-Efficient Windows | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy-Efficient Windows Energy-Efficient Windows Energy-Efficient Windows June 18, 2012 - 8:39am Addthis Energy-efficient windows provide space heating and lighting to this sunny kitchen. | Photo courtesy of Emily Minton-Redfield for Jim Logan Architects. Energy-efficient windows provide space heating and lighting to this sunny kitchen. | Photo courtesy of Emily Minton-Redfield for Jim Logan Architects. What does this mean for me? The windows in your house let in light and air if they're operable, but they can also be weak spots in your home's thermal envelope. When replacing windows, purchase the most energy-efficient windows you can afford, because they will pay for themselves over their lifetimes. Windows provide our homes with light, warmth, and ventilation, but they can also negatively impact a home's energy efficiency. You can reduce energy

425

Energy-Efficient Windows | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy-Efficient Windows Energy-Efficient Windows Energy-Efficient Windows June 18, 2012 - 8:39am Addthis Energy-efficient windows provide space heating and lighting to this sunny kitchen. | Photo courtesy of Emily Minton-Redfield for Jim Logan Architects. Energy-efficient windows provide space heating and lighting to this sunny kitchen. | Photo courtesy of Emily Minton-Redfield for Jim Logan Architects. What does this mean for me? The windows in your house let in light and air if they're operable, but they can also be weak spots in your home's thermal envelope. When replacing windows, purchase the most energy-efficient windows you can afford, because they will pay for themselves over their lifetimes. Windows provide our homes with light, warmth, and ventilation, but they can also negatively impact a home's energy efficiency. You can reduce energy

426

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Windows for New Construction Windows for New Construction Window Selection Tool Use the Window Selection Tool for new construction to compare performance of 20 different window types in your location. The Window Selection Tool will take you through a series of design conditions pertaining to your design and location. It is a step-by-step decision-making tool to help determine the most energy efficient window for your house. Window Selection Tool Window Selection Process This section provides step-by-step guidance on the window selection process for new construction windows including issues of code, energy, durability, and installation. Design Guidance This section provides Design Guides that examine the energy use impacts of new windows for homes in hot, mixed and cold climates. They show the the impact of orientation, window area, and shading. The energy use has been calculated for various window design variations including 5 orientations (equal, north, east, south, and west), 3 glazing areas, 20 glazing types, and 5 shading conditions.

427

Learning Windows Ibraheem A. Alhashim  

E-Print Network (OSTI)

. They suggest using a trainable classifier to learn a distance function that improves their fitting procedure. However, they do not implement such classifier and relay on a heuristic derived from their experimentation to ground truth of 744 windows from 40 test images. We will use a subset of the database they used for our

Zhang, Richard "Hao"

428

Covered Product Category: Residential Electric Resistance Water...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

with capacities of 20 to 120 gallons and maximum energy input of 12 kW. Residential heat pump and gas storage-type water heaters are covered by ENERGY STAR. Boilers, swimming...

429

CPS Energy- Solar Hot Water Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

As part of a larger program designed to reduce electricity demand within its service territory, CPS Energy now offers rebates for solar water heaters to its customers. In general, any CPS Energy...

430

IEA Heat Pump Conference 2011, 16 -19 May 2011, Tokyo, Japan DYNAMIC MODELING OF AN AIR SOURCE HEAT PUMP WATER  

E-Print Network (OSTI)

. Compared to those water heaters, heat pump water heating systems can supply much more heat just with the same amount of electric input used for electric water heaters. The ASHPWH absorbs heat from the ambient- 1 - 10th IEA Heat Pump Conference 2011, 16 - 19 May 2011, Tokyo, Japan DYNAMIC MODELING OF AN AIR

Paris-Sud XI, Université de

431

Mountain Association for Community Economic Development - Solar Water  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mountain Association for Community Economic Development - Solar Mountain Association for Community Economic Development - Solar Water Heater Loan Program Mountain Association for Community Economic Development - Solar Water Heater Loan Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info Funding Source Kentucky Solar Partnership (KSP) State Kentucky Program Type Local Loan Program Rebate Amount 100% of equipment and installation cost Provider Kentucky Solar Partnership The Kentucky Solar Partnership (KSP) and the Mountain Association for Community Economic Development (MACED) partner to offer low interest loans for the installation of solar water heaters. Loans cover the full equipment and installation cost. Flexible rate loans and terms are available. They

432

High Performance Windows Volume Purchase: Information Resources  

NLE Websites -- All DOE Office Websites (Extended Search)

Information Information Resources to someone by E-mail Share High Performance Windows Volume Purchase: Information Resources on Facebook Tweet about High Performance Windows Volume Purchase: Information Resources on Twitter Bookmark High Performance Windows Volume Purchase: Information Resources on Google Bookmark High Performance Windows Volume Purchase: Information Resources on Delicious Rank High Performance Windows Volume Purchase: Information Resources on Digg Find More places to share High Performance Windows Volume Purchase: Information Resources on AddThis.com... Home About For Builders For Residential Buyers For Light Commercial Buyers For Manufacturers For Utilities Information Resources Information Resources Numerous publications will be available to help educate buyers, product

433

LBNL Window & Daylighting Software -- RESFEN  

NLE Websites -- All DOE Office Websites (Extended Search)

SYSTEM REQUIREMENTS GET A COPY DOCUMENTATION KNOWLEDGE BASE Overview Today's energy-efficient windows can dramatically lower the heating and cooling costs associated with windows while increasing occupant comfort and minimizing window surface condensation problems. However, consumers are often confused about how to pick the most efficient window for a residence. Product information typically offers window properties: U-factors or R-values, Solar Heat Gain Coefficients or Shading Coefficients, and air leakage rates. However, the relative importance of these properties depends on site- and building-specific conditions. Furthermore, these properties are based on static evaluation conditions that are very different from the real situation a window will be used in.

434

New Whole-House Solutions Case Study: Tom Walsh & Co., Portland...  

Energy Savers (EERE)

caulking all penetrations * Windows: Double-pane, U 0.29 Lighting, Appliances, and Water Heating: * 100% compact fluorescent lighting * 62% efficient gas water heater * ENERGY...

435

Testing and analysis of the Semiscale Mod-1 heater rod design  

SciTech Connect

The use of electrically heated nuclear fuel rod simulators in the Semiscale Program is traced from a historical viewpoint. The design of the Semiscale Mod-1 electrical heater rod and core simulator is discussed. Heater rod thermal response during transient thermal-hydraulic depressurization experiments conducted in the Mod-1 system, and analysis techniques and tests conducted to help quantify heater rod characteristics and behavior are presented.

Larson, T.K.

1980-01-01T23:59:59.000Z

436

LBNL Window & Daylighting Software -- WINDOW 6 Research Version  

NLE Websites -- All DOE Office Websites (Extended Search)

(6.3.9) (6.3.9) October 2010 Last Updated: 11/07/2010 Complex Glazing Features for WINDOW6 The Research Version of WINDOW 6 has the following modeling capabilities: Shading Layer Library: A Shading Layer Library has been added to define shading systems, such as venetian blinds and diffusing layers, which can then be added as layers in the Glazing System Library. Shade Material Library: A Shading Material Library has been added to define materials to be used in the Shading Layer Library. Properties defined in this library include shade material reflectance and absorptance (in the solar, visible and IR wavelengths ranges), as well as the conductivity of the material. Glazing System Library In the “Layers” section of the Glazing System definition, it is now possible to specify either a glass layer or a shading layer. The shading system is chosen from the Shading Layer Library.

437

HEATER TEST PLANNING FOR THE NEAR SURFACE TEST FACILITY AT THE HANFORD RESERVATION  

E-Print Network (OSTI)

Heater Experiment at Hanford. Berkeley, Lawre ;e BerkeleyTest Facility, Hole DC-11, Hanford Reservation. Prepared forof Gable Mountain Basalt Cores, Hanford Nuclear Reservation.

DuBois, A.

2010-01-01T23:59:59.000Z

438

Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff Round Three  

Energy.gov (U.S. Department of Energy (DOE))

#EnergyFaceoff round three goes to the electric blanket, see how much more money it can save you over a space heater!

439

Development of solar air heaters & thermal energy storage system for drying applications in food processing industries.  

E-Print Network (OSTI)

??In the present work, the author has designed and developed all types of solar air heaters called porous and nonporous collectors. The developed solar air (more)

Sreekumar, A

2007-01-01T23:59:59.000Z

440

DOE Publishes Notice of Proposed Rulemaking for Direct Heating Equipment and Pool Heater Test Procedures  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy has published a notice of proposed rulemaking regarding test procedures for direct heating equipment and pool heaters.

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Green Systems Solar Hot Water  

E-Print Network (OSTI)

,2; basement) Pre-heats water so water heaters don't need to use as much energy Gas-powered, high efficiency heated water before it is circulated through the building Two gas boilers (GWB-1,2; basement) can be used

Schladow, S. Geoffrey

442

Comparison of Advanced Residential Water Heating Technologies in the United States  

SciTech Connect

Gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the US installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many preexisting models were used, new models of condensing and heat pump water heaters were created specifically for this work.

Maguire, J.; Fang, X.; Wilson, E.

2013-05-01T23:59:59.000Z

443

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Sash Replacement Sash Replacement DIY Network: How to Install a Window Sash Replacement Kit The DIY Network experts show you how to remove the window sash from an old double-hung window and install a new energy-saving sash replacement kit: How to Install a Window Sash Replacement Kit exit disclaimer . Sash replacement may be an alternative to a full window replacement or an insert window into an existing frame. The physical condition of the existing window must be good-there should be no moisture or air leakage. An energy auditor or replacement contractor may help you determine if a sash replacement is a viable option based on your homes window and wall conditions. Many manufacturers offer replacement sash kits, which include jamb liners to ensure good operability and fit. This option allows for relatively easy

444

IT Administrator's Guide to Using Windows Vista  

E-Print Network (OSTI)

IT Administrator's Guide to Using Windows Vista® for Sustainable IT Success Published: February Administrator's Guide to Using Windows Vista for Sustainable IT Success Contents Executive Summary ................................................................................................ 3 Sustainable IT Goals

Narasayya, Vivek

445

Simulating Complex Window Systems using BSDF Data  

E-Print Network (OSTI)

Daylighting, Design tools and methods INTRODUCTION Simulations enable designers and engineers to evaluate and select the best available window solutions

Konstantoglou, Maria

2011-01-01T23:59:59.000Z

446

A Design Guide for Early-Market Electrochromic Windows  

E-Print Network (OSTI)

Guide for Early-Market Electrochromic Windows. CaliforniaGuide for Early-Market Electrochromic Windows. CaliforniaGUIDE FOR EARLY-MARKET ELECTROCHROMIC WINDOWS Prepared For:

2006-01-01T23:59:59.000Z

447

A Design Guide for Early-Market Electrochromic Windows  

E-Print Network (OSTI)

Office worker preferences of electrochromic windows: a pilotDetails for an Electrochromic Window Wall Attached arethe performance of the electrochromic windows. Proceedings

2006-01-01T23:59:59.000Z

448

Alternatives for reducing hot-water bills  

SciTech Connect

A two stage approach to reducing residential water heating bills is described. In Stage I, simple conservation measures were included to reduce the daily hot water energy consumption and the energy losses from the water tank. Once these savings are achieved, Stage II considers more costly options for further reducing the water heating bill. Four alternatives are considered in Stage II: gas water heaters; solar water heaters (two types); heat pump water heaters; and heat recovery from a heat pump or air conditioner. To account for variations within the MASEC region, information on water heating in Rapid City, Minneapolis, Chicago, Detroit, and Kansas City is presented in detail. Information on geography, major population centers, fuel prices, climate, and state solar incentives is covered. (MCW)

Bennington, G.E.; Spewak, P.C.

1981-06-01T23:59:59.000Z

449

Stanek Windows | Open Energy Information  

Open Energy Info (EERE)

Stanek Windows Stanek Windows Jump to: navigation, search Name Stanek Windows Address 4565 Willow Parkway Place Cuyahoga Heights, Ohio Zip 44125 Sector Buildings, Efficiency Product Consulting; Installation; Maintenance and repair;Manufacturing; Retail product sales and distribution;Trainining and education Phone number 216-341-7700 Website http://www.stanekwindows.com Coordinates 41.435755°, -81.650183° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.435755,"lon":-81.650183,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

450

Full-scale cold-flow modelling of the SRC-I slurry fired heater at Creare, Inc. mixing and 1/sup 0/ downslope studies  

SciTech Connect

One of the major pieces of equipment in the SRC-I Demonstration Plant is the slurry fired heater. Because of the absence of any plant data at comparable combinations of operating severity, a cold-flow modelling experimental program was initiated at Creare, Inc. The first phase of the test program confirmed the fired heater design and established reliable boundaries of flow rates for proper operation of the fired heater. An experimental setup was designed and built at Creare to duplicate the piping arrangement and flow conditions of the fired heater. The pipe dimensions, flow rates, and fluid properties were selected to minimize areas of scale-up and extrapolation. This follow-up test program was developed to resolve concerns raised from the observations made in the first phase. Tests were conducted to establish the extent of mixing between the liquid carpet and the fast-moving liquid slugs above it. The other segment of the test program was designed to develop the flow regime and pressure drop data in the 1/sup 0/ downslope configuration. The results demonstrated a significant amount of mixing between the liquid carpet and the liquid slugs for water and the 400-cP fluid at the design flow conditions. The extent of mixing improved with increasing liquid and gas velocities and decreasing liquid viscosities. Adequate mixing was observed at liquid flow rates as low as 50% of the design flow conditions. Slug flow was observed at design conditions in the 1/sup 0/ downslope configuration. Although adequate mixing is expected in heater pipes, different techniques should be investigated to improve the extent of mixing, especially near the transition boundary. 4 references, 5 figures, 8 tables.

Mehta, D.C.

1984-05-01T23:59:59.000Z

451

Rigid thin windows for vacuum applications  

DOE Patents (OSTI)

A thin window that stands off atmospheric pressure is fabricated using photolithographic and wet chemical etching techniques and comprises at least two layers: an etch stop layer and a protective barrier layer. The window structure also comprises a series of support ribs running the width of the window. The windows are typically made of boron-doped silicon and silicon nitride and are useful in instruments such as electron beam guns and x-ray detectors. In an electron beam gun, the window does not impede the electrons and has demonstrated outstanding gun performance and survivability during the gun tube manufacturing process.

Meyer, Glenn Allyn (Danville, CA); Ciarlo, Dino R. (Livermore, CA); Myers, Booth Richard (Livermore, CA); Chen, Hao-Lin (Lafayette, CA); Wakalopulos, George (Pacific Palisades, CA)

1999-01-01T23:59:59.000Z

452

High Performance Windows Volume Purchase: Contacts  

NLE Websites -- All DOE Office Websites (Extended Search)

Contacts to Contacts to someone by E-mail Share High Performance Windows Volume Purchase: Contacts on Facebook Tweet about High Performance Windows Volume Purchase: Contacts on Twitter Bookmark High Performance Windows Volume Purchase: Contacts on Google Bookmark High Performance Windows Volume Purchase: Contacts on Delicious Rank High Performance Windows Volume Purchase: Contacts on Digg Find More places to share High Performance Windows Volume Purchase: Contacts on AddThis.com... Home About For Builders For Residential Buyers For Light Commercial Buyers For Manufacturers For Utilities Information Resources Contacts Web site and High Performance Windows Volume Purchase Program contacts are provided below. Website Contact Send us your comments, report problems, and/or ask questions about

453

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Selection Process for New Windows Selection Process for New Windows What are the benefits of energy-efficient windows? Energy & Cost Savings Improved Comfort Less Condensation Increased Light & View Reduced Fading Lower HVAC Costs How is window performance measured? U-factor Solar Heat Gain Coefficient Visible Transmittance Air Leakage Condensation Resistance Are there financing and incentive programs? Overview of Utility and State Programs Building Codes Energy Rating Programs 1. Meet the Energy Code and Look for the ENERGY STAR® Windows must meet the locally applicable energy code requirements. Windows that are ENERGY STAR qualified typically meet or exceed energy code requirements. A home's climate and location determine the relative importance of heating and cooling energy use, the applicable building energy code requirements, and the qualification criteria for ENERGY STAR windows. ENERGY STAR

454

Making Smart Windows Smarter | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Smart Windows Smarter Smart Windows Smarter Making Smart Windows Smarter April 5, 2011 - 2:00pm Addthis "Smart Windows" seen at light and dark settings. | Photo Courtesy of SAGE Electrochromics, Inc., by Susan Fleck Photography "Smart Windows" seen at light and dark settings. | Photo Courtesy of SAGE Electrochromics, Inc., by Susan Fleck Photography Roland Risser Roland Risser Program Director, Building Technologies Office What does this project do? Pleotint, LLC has developed a specialized glass film that uses the energy generated by the sun to limit excess heat and light from coming into homes and buildings. When you look out the window, you might notice whether the sun is shining, a nice view of the outdoors or an interesting cloud passing by. What most people probably don't notice is that traditional windows waste about 30

455

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Performance Standards Performance Standards Even the expert eye cannot easily tell an efficient window from a conventional window. That is why energy ratings, endorsement programs and consumer incentives play an important role in creating awareness for window energy efficiency among consumers, builders, architects and performance standard programs. Learn about NFRC certification and labeling Learn about ENERGY STAR® for windows, doors and skylights High Performance Windows and Low-E Storm Windows Volume Purchase Program Utility and State Incentives for energy efficiency improvements Building Codes Most locations have building energy codes that mandate minimum performance levels for windows, doors, and skylights. The builder, contractor or homeowner must adhere to the code requirements, which typically cover

456

PRELIMINARY THERMAL AND THERMOMECH-ANICAL MODELING FOR THE NEAR SURFACE TEST FACILITY HEATER EXPERIMANTS AT HANFORD: Appendix D  

E-Print Network (OSTI)

Heater Experiments at Hanford V O L U M E II (Appendix D) TENG-48 and for Rockwell Hanford Operations a Department ofFACILITY HEATER EXPERIMENTS AT HANFORD Volume 2 (Appendix D)

Chan, T.

2011-01-01T23:59:59.000Z

457

Spatially resolved temperature and heat flux measurements for slow evaporating droplets heated by a microfabricated heater array  

E-Print Network (OSTI)

The evaporation phenomenon of a liquid droplet was investigated by using microfabricated heaters. All 32 microheaters were designed to have the same resistance. Gold microheaters worked both as temperature indicators and as heaters. The first...

Paik, Sokwon

2006-08-16T23:59:59.000Z

458

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

459

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

460

Enhancement of Heat Transfer in an Artificially Roughened Solar Air Heater  

E-Print Network (OSTI)

Abstract: solar air heater is one of the basic equipment through which solar energy is converted into thermal energy. Solar air heaters, because of their simple in design, are cheap and most widely used collection devices of solar energy. The thermal efficiency of a solar air heater is significantly low because of the low value of the convective heat transfer coefficient between the absorber plate and the air, leading to high absorber plate temperature and high heat losses to the surroundings. This paper presents the study of heat transfer in a solar air heater by using Computational Fluid Dynamics (CFD). The effect of Reynolds number on Nusselt number is investigated. A commercial finite volume package ANSYS FLUENT 12.1 is used to analyze and visualize the nature of the flow across the duct of a solar air heater.

unknown authors

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity  

Science Journals Connector (OSTI)

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity ...

Judy L. Mumford; Ron W. Williams; Debra B. Walsh; Robert M. Burton; David J. Svendsgaard; Jane C. Chuang; Virginia S. Houk; Joellen Lewtas

1991-10-01T23:59:59.000Z

462

One Machine for Heating Cooling & Domestic Hot Water: Multi-Function Heat Pumps to Enable Zero Net Energy Homes  

E-Print Network (OSTI)

advances to commercialize stand-alone electric heat-pump storage hot water heaters. These systems offer design uses multiple systems and fuels to provide thermal services, the emerging generation of heat to experience this change as air-source heat-pump water heaters deliver obvious energy savings over electric

California at Davis, University of

463

Energy-efficient water heating  

SciTech Connect

This fact sheet describes how to reduce the amount of hot water used in faucets and showers, automatic dishwashers, and washing machines; how to increase water-heating system efficiency by lowering the water heater thermostat, installing a timer and heat traps, and insulating hot water pipes and the storage tank; and how to use off-peak power to heat water. A resource list for further information is included.

NONE

1995-01-01T23:59:59.000Z

464

Building America Standing Technical Committee - Water Heating  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heating Standing Technical Committee Strategic Plan, v2012a Revised: January 2012 Committee Chair: 2011, 2012 Marc Hoeschele mhoesch@davisenergy.com 530-753-1100 x23 ARBI Page 2 Background on Residential Water Heating According to the U.S. Energy Information Administration's 2005 Residential Energy Consumption Survey (RECS), annual residential water heating totals 2.11 quads of energy annually, or 20% of the energy delivered to residential buildings 1 . Over the past 70 years, gas and electric storage water heaters have been the predominant water heater type in the United States 2 . Recently, gas tankless water heaters have made inroads in market share with current industry projected gas tankless sales estimated at 400,000+ annually, and an

465

Numerical Analysis of Water Temperature Distribution in the Tank of ASHPWH it ha Cylindrical Condenser  

E-Print Network (OSTI)

Air source heat pump water heaters (ASHPWH) are becoming increasingly popular for saving energy, protecting the environment and security purposes. The water temperature distribution in the tank is an important parameter for an ASHPWH. This paper...

Wang, D.; Shan, S.; Wang, R.

2006-01-01T23:59:59.000Z

466

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Design Guidance for Replacement Windows Design Guidance for Replacement Windows Opportunities for Design Improvements Energy-efficient windows offer benefits under diverse design conditions. Window performance can be improved by taking orientation, window area and shading into account. Fine-tuning your window selection to the houses conditions and optimizing these conditions where possible helps further cut heating and cooling demand. Besides long-term energy savings, these upfront opportunities may be available: Smaller HVAC equipment: Lower heating and cooling demand means optimum equipment is smaller and costs less. ENERGY STAR Homes recognition: High-performance design can allow homes to be recognized by the ENERGY STAR program. Many States and localities offer design help and/or incentives for ENERGY STAR homes.

467

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Considerations for Window Performance Considerations for Window Performance Advanced window technologies can have a major effect on comfort and on the annual energy performance of a house. However, there is a broader and possibly more significant impact of the recent revolution in window performance. Because the new glazing technologies provide highly effective insulating value and solar protection, there are important implications for how a house is designed. There is a long-established set of window design guidelines and assumptions intended to reduce heating and cooling energy use. These are based, in part, on the historical assumption that windows were the weak link in the building envelope. These assumptions frequently created limitations on design freedom or generated conflicts with other performance requirements,

468

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

The High Performance Windows Volume Purchase (WVP) Program The High Performance Windows Volume Purchase (WVP) Program The U.S. Department of Energy's Building Technologies Program (BTP) is coordinating a volume purchase program intended to overcome cost and awareness barriers to the wider adoption of highly-insulating windows and low-E storm windows. These products include windows meeting a number of specifications including a U-factor of 0.22 or less as well as storm windows with low-emissivity glass. Buyer groups with a potential interest in purchasing these products in volume will learn about their availability and cost through the program's product listings. Over 50 manufacturers proposed products for the first round of these listings, for which submittals were due by February 19, 2010. DOE does not purchase any products through this project, nor does DOE

469

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidance on Window Durability Guidance on Window Durability There is no simple rating or absolute guarantee of the durability of a window. You may want to study the design and workmanship of the window and rely on recommendations from others who have used similar products. The advice of experienced architects and builders can be helpful. As with other products, warranties can be an indicator of the reliability of the window and its manufacturer. Durability may vary with location; for example, some materials are degraded by salt near the ocean. These aspects of window durability deserve special attention: frame and sashes; insulating glass seals; weatherstripping; and local requirements for structural integrity. Frame and Sashes Although design and workmanship may be the most important factors

470

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Financing & Incentives Financing & Incentives Financing or incentive programs may be available to you if: You intend to replace old windows with high-performance, energy efficient windows. You plan to build a new home with windows that keep energy costs low and provide for a comfortable interior. If you are looking for utility programs within your state that can help you finance such an investment in efficient windows, download an overview of utility and state programs. Incentives and Rebates for Energy-Efficient Windows Offered through Utility and State Programs Utility and State Incentives We have provided an overview of utility and state programs that can help you as a resident, building owner, or builder to finance improvements in window energy efficiency. Download an overview of utility and state

471

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Measuring Performance: ENERGY STAR® Windows Measuring Performance: ENERGY STAR® Windows Windows for residential buildings are eligible for ENERGY STAR Most Efficient recognition in 2013. View the criteria for windows for the ENERGY STAR Most Efficient Program. Energy Star Most Efficient Program The Department of Energy (DOE) and the Environmental Protection Agency (EPA) have developed an ENERGY STAR exit disclaimer designation for products meeting certain energy performance criteria. Windows that have the ENERGY STAR designation will be labeled showing the zones in which it is qualified. Since energy efficient performance of windows, doors, and skylights varies by climate, product recommendations are given for four U.S. climate zones. For making comparisons among ENERGY STAR products, use the NFRC label or

472

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Fresh Air Fresh Air Windows provide the primary means to control air flow in most homes. People open windows to provide fresh air, ventilate odors and smoke, dissipate heat and moisture, and create air movement on hot days. While exhaust fans and central air systems can mechanically ventilate a room, opening a room to the outdoors is perceived as more direct and natural. Guidelines for Providing Fresh Air Place operable windows in all rooms to give occupants opportunity for fresh air. Provide cross-ventilation by placing window openings on opposite walls in line with the prevailing winds. Use casement windows to direct and control ventilation. Use operable skylights or roof windows to enhance ventilation. Use landscape elements to direct breezes. In order to ensure that all residences have access to the healthful aspects

473

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Design Guidance for New Windows Design Guidance for New Windows Opportunities for Design Improvements Energy-efficient windows offer benefits under diverse design conditions. Window performance can be improved by taking orientation, window area and shading into account. Fine-tuning your window selection to the houses conditions and optimizing these conditions where possible helps further cut heating and cooling demand. Besides long-term energy savings, these upfront opportunities may be available: Smaller HVAC equipment: Lower heating and cooling demand means optimum equipment is smaller and costs less. ENERGY STAR Homes recognition: High-performance design can allow homes to be recognized by the ENERGY STAR program. Many States and localities offer design help and/or incentives for ENERGY STAR homes.

474

Building Energy Software Tools Directory: Window  

NLE Websites -- All DOE Office Websites (Extended Search)

Window Window WINDOW screenshot. Calculates thermal performance of fenestration products; heat transfer analysis method consistent with the rating procedure developed by the National Fenestration Rating Council (NFRC). Screen Shots Keywords fenestration, thermal performance, solar optical characteristics, windows, glazing Validation/Testing N/A Expertise Required Some knowledge about windows. Users 2000+ in the U.S. and abroad. Audience Manufacturers, engineers, architects, researchers, sales personnel. Input Interactive program: user-provided data files for frames (from the THERM program) and glazing layers (from the Optics program) optional. Output Reports for the total window can be saved to disk or printed; files can be generated to be used as input to the DOE-2 and EnergyPlus programs;

475

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Measuring Performance Measuring Performance What are the benefits of energy-efficient windows? Energy & Cost Savings Improved Comfort Less Condensation Increased Light & View Reduced Fading Lower HVAC Costs Looking for information on windows for a new house? Window Selection Tool Selection Process Design Guidance Installation Looking for information on replacement windows? Window Selection Tool Assessing Options Selection Process Design Guidance Installation U-factor The rate of heat loss is indicated in terms of the U-factor (U-value) of a window assembly. This section on U-factor describes what a U-factor is and it's importance in the heat loss through a window assembly. U-factor Solar Heat Gain Coefficient (SHGC) The SHGC is the fraction of incident solar radiation admitted through a window, both directly transmitted and absorbed and subsequently released inward. This section on Solar Heat Gain Coefficient describes what a SHGC is and it's importance in the amount of heat gain through a window assembly.

476

List of Windows Incentives | Open Energy Information  

Open Energy Info (EERE)

Windows Incentives Windows Incentives Jump to: navigation, search The following contains the list of 604 Windows Incentives. CSV (rows 1-500) CSV (rows 501-604) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP (Central and North) - CitySmart Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional Local Government Schools Boilers Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Furnaces Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Roofs Windows Yes AEP (Central, North and SWEPCO) - Commercial Solutions Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional Local Government Nonprofit Schools

477

THERMAL PERFORMANCE OF INSULATING WINDOW SYSTEMS  

E-Print Network (OSTI)

Efficient Use of Energy, New York (1975). Glaser, V.H.J. , "Energy Transport Control in Window Systems", Report ETR-1277-2, Stony Brook, New York, (

Selkowitz, Stephen E.

2011-01-01T23:59:59.000Z

478

A Review of Electrochromic Window Performance Factors  

E-Print Network (OSTI)

influence the market acceptance of electrochromic windowsfor the eventual market success of electrochromic windows inearly niche market might consist of adding an electrochromic

Selkowitz Ed, S.E.

2010-01-01T23:59:59.000Z

479

Performance tests of large thin vacuum windows  

SciTech Connect

Tests of thin composition vacuum windows of the type used for the Tagger in Hall B at the Thomas Jefferson National Accelerator Facility are described. Three different tests have been performed. These include: (1) measurement of the deformation and durability of a window under long term (>8 years) almost continuous vacuum load, (2) measurement of the deformation as a function of flexing of the window as it is cycled between vacuum and atmosphere, and (3) measurement of the relative diffusion rate of gas through a variety of thin window membranes.

Hall Crannell

2011-02-01T23:59:59.000Z

480

Creating a Comprehensive Solar Water Heating Deployment Strategy  

SciTech Connect

This report details the results of a research conducted in 1998 and 1999 and outlines a marketing deployment plan designed for businesses interested in marketing solar water heaters in the new home industry.

Focus Marketing Services

1999-08-18T23:59:59.000Z

Note: This page contains sample records for the topic "water heaters windows" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

NV Energy (Southern Nevada)- Solar Hot Water Incentive Program  

Energy.gov (U.S. Department of Energy (DOE))

NV Energy is providing an incentive for its residential customers to install solar water heaters on their homes. As of July 26, 2013, NV Energy electric customers in Southern Nevada who own their...

482

Lumbee River EMC- Solar Water Heating Rebate Program (North Carolina)  

Energy.gov (U.S. Department of Energy (DOE))

Lumbee River EMC is offering $850 rebates to residential customers who install solar water heaters on their homes. To qualify, the systems must be certified OG-300 by the Solar Ratings and...

483

Lumbee River EMC- Solar Water Heating Loan Program (North Carolina)  

Energy.gov (U.S. Department of Energy (DOE))

Lumbee River EMC is offering 1.50% loans to residential customers for the installation of solar water heaters on their homes. To qualify, the systems must be certified OG-300 by the Solar Ratings...

484

Evaluation of a Stirling engine heater bypass with the NASA Lewis nodal-analysis performance code  

SciTech Connect

In support of the US Department of Energy's Stirling Engine Highway Vehicle Systems program, the NASA Lewis Research Center investigated whether bypassing the P-40 Stirling engine heater during regenerative cooling would improve the engine thermal efficiency. The investigation was accomplished by using the Lewis nodal-analysis Stirling engine computer model. Bypassing the P-40 Stirling engine heater at full power resulted in a rise in the indicated thermal efficiency from 40.6 to 41.0 percent. For the idealized (some losses not included) heater bypass that was analyzed, this benefit is not considered significant.

Sullivan, T.J.

1986-05-01T23:59:59.000Z

485

High Performance Windows Volume Purchase: About the High Performance  

NLE Websites -- All DOE Office Websites (Extended Search)

High Performance Windows Volume Purchase: About the High Performance Windows Volume Purchase: About the High Performance Windows Volume Purchase Program to someone by E-mail Share High Performance Windows Volume Purchase: About the High Performance Windows Volume Purchase Program on Facebook Tweet about High Performance Windows Volume Purchase: About the High Performance Windows Volume Purchase Program on Twitter Bookmark High Performance Windows Volume Purchase: About the High Performance Windows Volume Purchase Program on Google Bookmark High Performance Windows Volume Purchase: About the High Performance Windows Volume Purchase Program on Delicious Rank High Performance Windows Volume Purchase: About the High Performance Windows Volume Purchase Program on Digg Find More places to share High Performance Windows Volume Purchase:

486

BT::Electrochromic Windows Resources  

NLE Websites -- All DOE Office Websites (Extended Search)

spacer spacer spacer spacer Resources spacer Industry Contacts | CA Utility Contacts | R&D Organizations | Technical Reports | References | Acknowledgements | Project Team spacer Industry Contacts As of 2006, SAGE Electrochromics, Inc. is the only manufacturer in the U.S. selling electrochromic-coated glass units for building applications: Lou Podbelski SAGE Electrochromics, Inc. One Sage Way Faribault, MN 55021 (507) 331-4935 http://www.sage-ec.com/ SAGE's first market entry was to provide electrochromic coated glass to Velux for their switchable electrochromic skylight product line: electric venting skylights, fixed skylights, and fixed curb-mounted skylights in various rectangular sizes. They now market to a variety of window and curtain wall suppliers; contact SAGE for current supplier information.

487

Laser sealed vacuum insulating window  

DOE Patents (OSTI)

A laser sealed evacuated window panel is comprised of two glass panes held spaced apart in relation to each other by a plurality of spherical glass beads and glass welded around the edges to provide an evacuated space between the glass panes that is completely glass sealed from the exterior. The glass welded edge seal is obtained by welding the edges of the glass panes together with a laser beam while the glass panes and bead spacers are positioned in a vacuum furnace and heated to the annealing point of the glass to avoid stress fracture in the area of the glass weld. The laser welding in the furnace can be directed around the perimeter of the galss panel by a combination of rotating the glass panel and linearly translating or aiming the laser with a relay mirror.

Benson, D.K.; Tracy, C.E.

1985-08-19T23:59:59.000Z

488

Laser sealed vacuum insulation window  

DOE Patents (OSTI)

A laser sealed evacuated window panel is comprised of two glass panes held spaced apart in relation to each other by a plurality of spherical glass beads and glass welded around the edges to provide an evacuated space between the glass panes that is completely glass sealed from the exterior. The glass welded edge seal is obtained by welding the edges of the glass panes together with a laser beam while the glass panes and bead spacers are positioned in a vacuum furnace and heated to the annealing point of the glass to avoid stress fracture in the area of the glass weld. The laser welding in the furnace can be directed around the perimeter of the glass panel by a combination of rotating the glass panel and linearly translating or aiming the laser with a relay mirror.

Benson, David K. (Golden, CO); Tracy, C. Edwin (Golden, CO)

1987-01-01T23:59:59.000Z

489

PowerSaver Loans | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

doors and windows; heating, ventilation, and air conditioning systems; water heaters; solar panels; and geothermal systems. The PowerSaver program is currently in a pilot...

490

DOE and HUD Announce Lenders to Participate in New Pilot Program...  

Office of Environmental Management (EM)

of insulation, duct sealing, replacement doors and windows, HVAC systems, water heaters, solar panels, and geothermal systems. U.S. Housing and Urban Development (HUD) Secretary...

491

Windows Registry Forensics: Advanced Digital Forensic Analysis of the Windows Registry  

Science Journals Connector (OSTI)

Harlan Carvey brings readers an advanced book on Windows Registry. The first book of its kind EVER -- Windows Registry Forensics provides the background of the Registry to help develop an understanding of the binary structure of Registry hive files. ...

Harlan Carvey

2011-02-01T23:59:59.000Z

492

Review of International Methods of Test to Rate the Efficiency of Water  

NLE Websites -- All DOE Office Websites (Extended Search)

Review of International Methods of Test to Rate the Efficiency of Water Review of International Methods of Test to Rate the Efficiency of Water Heaters Title Review of International Methods of Test to Rate the Efficiency of Water Heaters Publication Type Report LBNL Report Number LBNL-5187E Year of Publication 2011 Authors Lutz, James D. Subsidiary Authors Energy Analysis Department Document Number LBNL-5187E Pagination 21 Date Published January Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5187E Abstract The American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standards Project Committee (SPC) 118.2, Method of Testing for Rating Residential Water Heaters, is seeking to improve the test procedure used for measuring the energy efficiency of residential gas and electric water heaters. ASHRAE is seeking to develop an improved test procedure in part to support the U.S. Department of Energy's (DOE's) desire to update and amend the water heater test procedure underlying the minimum energy efficiency standards for water heaters. DOE's test procedures are often based on or reference ASHRAE standards.DOE's most recent minimum energy performance standards (MEPS) for residential water heaters were promulgated in 2010.[1] The associated test procedures are stipulated in the Code of Federal Regulations (CFR).[2] Although DOE currently is conducting a rulemaking to review and possibly amend the test procedures for residential water heaters, that rulemaking pertains to accounting for energy consumed during standby and off modes. In its notice of proposed rulemaking published in the Federal Register on August 30, 2010, DOE tentatively concluded that the test procedure for water heaters already fully accounts for and incorporates the energy consumed during standby and off modes [3].

493

Windows Mobile LiveSD Forensics  

Science Journals Connector (OSTI)

More and more often, smartphones are relevant targets of civil and criminal investigations. Currently, there are several tools available to acquire forensic evidence from smartphones. Unfortunately, most of these tools require to connect the smartphone ... Keywords: Data acquisition, Mobile device forensics, PocketPC forensics, Window CE forensics, Windows Mobile Forensics

EyP S. Canlar; Mauro Conti; Bruno Crispo; Roberto Di Pietro

2013-03-01T23:59:59.000Z

494

A Small Scale Solar Agricultural Dryer with Biomass Burner and Heat Storage Back-Up Heater  

Science Journals Connector (OSTI)

This paper describes a small scale solar agricultural dryer with a simple biomass burner and heat storage back-up heater. The key design features ... are the combination of direct and indirect type solar dryer, t...

Elieser Tarigan; Perapong Tekasakul

2009-01-01T23:59:59.000Z

495

Thermal performance evaluation of a solar air heater with and without thermal energy storage  

Science Journals Connector (OSTI)

This communication presents the experimental study and performance analysis of a solar air heater with and without phase change ... found that the output temperature in case with thermal energy storage (TES) is h...

V. V. Tyagi; A. K. Pandey; S. C. Kaushik

2012-03-01T23:59:59.000Z

496

Combustion air preheating for refinery heaters using plate-type heat exchangers  

SciTech Connect

Combustion air preheating by recovering heat from combustion gases is a cost effective method of increasing the overall thermal efficiency of the refining and petrochemical processes. This paper presents the advantages of the plate-type air preheaters made of smooth plates without extended surfaces. These exchangers provide a relatively high heat transfer coefficient at a relatively low pressure drop, resulting in a flexible and compact design. The air preheater design can easily be integrated into the heater design. Top mounting with natural draft becomes possible for many applications, eliminating the need for I.D. fan and expensive ductwork. The economical extent of heat recovery function of the fuel fired is presented based on practical experience. The use of porcelain enameled (glass coated) plates and of stainless steel materials allows the operation of the air preheater below the acidic and water dew point. Finally the paper presents the experience of the Canadian refineries and petrochemical plants with plate-type heat exchangers used for combustion air preheating.

Dinulescu, M.

1987-01-01T23:59:59.000Z

497

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Window Technologies Window Technologies Operator Types Traditional operable window types include the projected or hinged types such as casement, awning, and hopper, and the sliding types such as double- and single-hung and horizontal sliding. This section on Operator Types describes how these typical windows work. Operator Types Glazing Types Traditionally, windows have been made from clear glass, but advanced technologies have significantly improved the thermal performance of glass. This section on Glazing Types describes some of these technologies. Glazing Types Gas Fills Gas fills improve the thermal performance of insulating glazing units by reducing the conductance of the air space between the layers. This section on Gas Fills describes the thermal performance benefits of adding gas to an IGU.

498

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Exterior Shading Exterior Shading Window Attachments For detailed information on storm windows and other window attachments, visit www.windowattachments.org exit disclaimer , a site supported by Lawrence Berkeley National Laboratory, Building Green, and the U.S. Department of Energy. DOE's Energy Savers You can improve the energy efficiency of existing windows by various additions to an existing window. Awnings exit disclaimer Blinds exit disclaimer Draperies exit disclaimer Overhangs exit disclaimer Shades exit disclaimer Shutters exit disclaimer Awnings in Residential Buildings Study showing that awnings have advantages that contribute to more sustainable buildings. Download Awnings in Residential Buildings exit disclaimer The most effective way of reducing solar heat gain is to block the sun's

499

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Fact Sheets & Publications: Books Fact Sheets & Publications: Books Residential Windows: A Guide to New Technology and Energy Performance Available from Norton Professional Books. exit disclaimer Single copy price: $35.00 USA; volume discounts available from publisher. Available from Amazon. exit disclaimer Window Systems for High-performance Buildings Available from Norton Professional Books. exit disclaimer Single copy price: $50.00 USA; volume discounts available from publisher. Available from Amazon. exit disclaimer Residential Windows: A Guide to New Technology and Energy Performance, 3rd Edition John Carmody, Stephen Selkowitz, Dariush Arasteh and Lisa Heschong Residential Windows The Department of Energy's Windows and Glazing Research Program supported the development of this book. Support was provided

500

Welcome to the Efficient Windows Collaborative  

NLE Websites -- All DOE Office Websites (Extended Search)

Reduced Condensation Reduced Condensation Condensation High performance windows with new glazing technologies not only reduce energy costs but make homes more comfortable as well. High-performance windows create warmer interior glass surfaces, reducing frost and condensation. High-performance windows with warm edge technology and insulating frames have such a warm interior surface that condensation on any interior surfaces is significantly reduced under all conditions. Condensation occurs when the interior surface temperature of the glass drops below either the dewpoint or frost point. A window's frame and/or glazing system can contribute to the possibility of condensation if they are poor performers for a specific climate. High-performance windows create warmer interior glass surfaces, reducing condensation and frost.