National Library of Energy BETA

Sample records for water heater research

  1. Heat Pump Water Heaters: Controlled Field Research of Impact...

    Office of Scientific and Technical Information (OSTI)

    Water Heaters: Controlled Field Research of Impact on Space Conditioning and Demand Response Characteristics Citation Details In-Document Search Title: Heat Pump Water Heaters: ...

  2. Making Water Heaters More Efficient | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Making Water Heaters More Efficient Click to email this to a friend (Opens in new window) ... Making Water Heaters More Efficient Jigar Shah 2013.11.13 As children, many of us grow up ...

  3. Water Heaters | Open Energy Information

    Open Energy Info (EERE)

    Water Heaters Jump to: navigation, search TODO: Add description List of Water Heaters Incentives Retrieved from "http:en.openei.orgwindex.php?titleWaterHeaters&oldid267202"...

  4. Selecting a new water heater

    SciTech Connect (OSTI)

    1995-03-01

    This fact sheet describes the types of water heaters available (storage water heaters, demand water heaters, heat pump water heaters, tankless coil and indirect water heaters, and solar water heaters). The criteria for selection are discussed. These are capacity, efficiency rating, and cost. A resource list is provided for further information.

  5. Residential Absorption Water Heater

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Residential Absorption Water Heater 2014 Building Technologies Office Peer Review Kyle ... Target MarketAudience: Residential gas water heating Key Partners: GE CRADA partner SRA ...

  6. Heat Pump Water Heaters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    & Events Expand News & Events Skip navigation links Residential Residential Lighting Energy Star Appliances Consumer Electronics Heat Pump Water Heaters Electric Storage Water...

  7. Electric Storage Water Heaters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    & Events Expand News & Events Skip navigation links Residential Residential Lighting Energy Star Appliances Consumer Electronics Heat Pump Water Heaters Electric Storage Water...

  8. Low-cost Batch Solar Water Heater research and development project. Final report

    SciTech Connect (OSTI)

    Stickney, B.L.

    1983-06-01

    This report presents a summary of the development and testing of Batch Solar Water Heaters. Batch Heaters tested include several kinds of tank-under-glass (Breadbox) models and several types of Inverted Batch Solar Water Heaters with both fixed and moveable reflector systems. Temperature graphs and tables of performance indices are presented for each water heater tested. An Inverted Batch Water Heater was developed based upon the test results called the Bottomgainer. Two prototypes of the Bottomgainer model were installed and monitored in use on residences. The Bottomgainer concept could be adapted to commercial production.

  9. Solar Water Heater Roadmap Leads Path to Market Expansion (Fact...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace. Researchers in the Residential ...

  10. Storage Water Heaters | Department of Energy

    Energy Savers [EERE]

    Storage Water Heaters Storage Water Heaters Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy ...

  11. Tankless Coil and Indirect Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters An indirect water heater. An indirect water heater. Tankless coil and indirect water heaters use a home's...

  12. Tankless Coil and Indirect Water Heaters | Department of Energy

    Energy Savers [EERE]

    Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters An indirect water heater. An indirect water heater. Tankless coil and indirect water heaters use a home's ...

  13. Absorption Heat Pump Water Heater

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water ...

  14. Chaudagaz condensation water heater

    SciTech Connect (OSTI)

    Nocturne, P.

    1982-01-01

    The Chaudagaz water heater offers (1) a high heating capacity (40 kW) through the use of a ventilator-equipped burner, (2) quick warmup (less than 20 min), and (3) high heating efficiency (85% upper calorific value) obtained by a unique heat-recovery system. The combustion products rise through a central cylinder, then flow downward along stainless-steel spiral tubing, warming the water and exiting from the bottom of the tank. This natural flow allows easy discharge of condensates and prevents cold air from sweeping through the stack when the burner is off.

  15. Portable solar water heater

    SciTech Connect (OSTI)

    Borodulin, G.; Baron, R.; Shkolnik, A.

    1985-11-12

    A combined table and portable solar water heater comprises a suitcase-like rigid casing molded from a rigid plastic material which contains a pair of solar collector panels and connected in series. The panels can be exposed to solar radiation when the casing is opened. Each collector panel or is formed by a copper plate with the solar radiation absorbing surface and copper pipe coil or in heat-transferring relationship with said copper plate. The casing is provided with compartments for accessories, such as adjustable legs for supporting the casing, adjusting its angle to incident sunlight, and for converting the casing into a table; containers for feeding cold water to the solar collector and for receiving hot water from the collector; and a tripod stand for supporting the feeding container at the level above the collector and for arranging a shower set. Temperature-insulating layers of the collectors are formed by separate pieces of rigid material which can be removed from the casing and assembled into a box-shaped container which can be utilized for maintaining water heated by means of the solar water heater at an elevated temperature.

  16. Water heater control module

    DOE Patents [OSTI]

    Hammerstrom, Donald J

    2013-11-26

    An advanced electric water heater control system that interfaces with a high temperature cut-off thermostat and an upper regulating thermostat. The system includes a control module that is electrically connected to the high-temperature cut-off thermostat and the upper regulating thermostat. The control module includes a switch to open or close the high-temperature cut-off thermostat and the upper regulating thermostat. The control module further includes circuitry configured to control said switch in response to a signal selected from the group of an autonomous signal, a communicated signal, and combinations thereof.

  17. Selecting a New Water Heater | Department of Energy

    Energy Savers [EERE]

    Heat & Cool Water Heating Selecting a New Water Heater Selecting a New Water Heater Water heater testing facility at Oak Ridge National Laboratory. Water heater testing ...

  18. Solar Water Heater Basics | Department of Energy

    Energy Savers [EERE]

    Water Heating Solar Water Heater Basics Solar Water Heater Basics August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel ...

  19. Heat Pump Water Heaters | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    A diagram of a heat pump water heater. A diagram of a heat pump water heater. What does this mean for me? Heat pump water heaters can be two to three times more energy efficient...

  20. Do You Have a Solar Water Heater?

    Broader source: Energy.gov [DOE]

    Earlier this week, Ernie wrote about the economics of getting a solar water heater. As Ernie explained, a solar water heater is more expensive than a normal water heater, but depending on your area...

  1. Storage Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Storage Water Heaters Storage Water Heaters June 15, 2012 - 6:00pm Addthis Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over...

  2. Water Heater Controller - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Find More Like This Return to Search Water Heater Controller Pacific Northwest National Laboratory Contact PNNL About This Technology Water heaters can be retrofitted to ...

  3. DOE_Water_Heater_Meeting_111612.pdf

    Broader source: Energy.gov (indexed) [DOE]

    Conservation Standards for Residential Water Heaters", the comments filed therein, and ... that Joint Commenters had done with water heater manufacturers to identify ...

  4. Field Monitoring Protocol: Heat Pump Water Heaters

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Field Monitoring Protocol: Heat Pump Water Heaters B. Sparn, L. Earle, D. Christensen, J. ... 2013 Field Monitoring Protocol: Heat Pump Water Heaters B. Sparn, L. Earle, D. ...

  5. Promising Technology: Heat Pump Water Heaters

    Broader source: Energy.gov [DOE]

    A heat pump water heater uses electricity to transfer heat from the ambient air to stored water, as opposed to an electric resistance water heater, which uses electricity to generate the heat directly. This enables the heat pump water heater to be 2 to 3 times as efficient as an electric resistance water heater.

  6. Promising Technology: Tankless Gas Water Heaters

    Broader source: Energy.gov [DOE]

    A tankless gas water heater does not have a storage tank, as a conventional water heater does. Instead, a tankless water heater instantaneously heats water flowing over the heat exchanger coils when there is hot water demand. Because there is no tank, tankless water heaters have no standby energy losses that are associated with storage units. Another non-energy saving benefit is that a tankless water heater is much more compact.

  7. Tankless or Demand-Type Water Heaters | Department of Energy

    Energy Savers [EERE]

    or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters Diagram of a tankless water heater. Diagram of a tankless water heater. Tankless water heaters, also known as ...

  8. Heat Pump Water Heaters: Controlled Field Research of Impact on Space Conditioning and Demand Response Characteristics

    SciTech Connect (OSTI)

    Parker, Graham B.; Widder, Sarah H.; Eklund, Ken; Petersen, Joseph M.; Sullivan, Greg

    2015-10-05

    A new generation of heat pump water heaters (HPWH) has been introduced into the U.S. market that promises to provide significant energy savings for water heating. Many electric utilities are promoting their widespread adoption as a key technology for meeting energy conservation goals and reducing greenhouse gas emissions. There is, however, considerable uncertainty regarding the space conditioning impact of an HPWH installed in a conditioned space. There is also uncertainty regarding the potential for deployment of HPWHs in demand response (DR) programs to help manage and balance peak utility loads in a similar manner as conventional electric resistance water heaters (ERWH). To help answer these uncertainties, controlled experiments have been undertaken over 30 months in a matched pair of unoccupied Lab Homes located on the campus of the Pacific Northwest National Laboratory (PNNL) in Richland, Washington.

  9. Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models: Preprint

    SciTech Connect (OSTI)

    Hudon, K.; Sparn, B.; Christensen, D.; Maguire, J.

    2012-02-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. Laboratory results demonstrate the efficiency of this technology under most of the conditions tested and show that differences in control schemes and design features impact the performance of the individual units. These results were used to understand current model limitations, and then to bracket the energy savings potential for HPWH technology in various US climate regions. Simulation results show that HPWHs are expected to provide significant energy savings in many climate zones when compared to other types of water heaters (up to 64%, including impact on HVAC systems).

  10. Molded polymer solar water heater

    DOE Patents [OSTI]

    Bourne, Richard C.; Lee, Brian E.

    2004-11-09

    A solar water heater has a rotationally-molded water box and a glazing subassembly disposed over the water box that enhances solar gain and provides an insulating air space between the outside environment and the water box. When used with a pressurized water system, an internal heat exchanger is integrally molded within the water box. Mounting and connection hardware is included to provide a rapid and secure method of installation.

  11. Promising Technology: Condensing Gas Water Heaters

    Broader source: Energy.gov [DOE]

    Condensing water heaters achieve higher efficiencies than conventional water heaters by capturing the latent heat from water vapor contained in the flue gases. Combustion gases are exhausted through a secondary heat exchanger where the latent heat of water vapor in the exhaust gas is transferred to the stored water. This technology enables the water heater to achieve thermal efficiencies up to 99%.

  12. A Combined Water Heater, Dehumidifier, and Cooler (WHDC) | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    A Combined Water Heater, Dehumidifier, and Cooler (WHDC) A Combined Water Heater, Dehumidifier, and Cooler (WHDC) Figure 1: The system model for the combined Water heater, ...

  13. Selecting a New Water Heater | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Water heater testing facility at Oak Ridge National Laboratory. Water heater testing facility at Oak Ridge National Laboratory. When selecting a new water heater for your home, ...

  14. Tankless Gas Water Heater Performance - Building America Top...

    Energy Savers [EERE]

    Tankless Gas Water Heater Performance - Building America Top Innovation Tankless Gas Water Heater Performance - Building America Top Innovation This photo shows a hot water heater ...

  15. NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models. 2012 ASHRAE Winter Conference, Chicago, IL, January 21-25, 2012. NREL Report ...

  16. NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models. ASHRAE Transactions 2012, Vol. 118, Part 1. www.nrel.govdocsfy12osti...

  17. NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet)

    SciTech Connect (OSTI)

    Hudon, K.

    2012-05-01

    A new simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes.

  18. Heat Pump Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heat Pump Water Heaters Heat Pump Water Heaters A diagram of a heat pump water heater. A diagram of a heat pump water heater. Most homeowners who have heat pumps use them to heat and cool their homes. But a heat pump also can be used to heat water -- either as stand-alone water heating system, or as combination water heating and space conditioning system. How They Work Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. Therefore,

  19. Residential CO2 Heat Pump Water Heater | Department of Energy

    Energy Savers [EERE]

    Residential CO2 Heat Pump Water Heater Residential CO2 Heat Pump Water Heater CO2 Heat Pump Water Heater Prototype
    Credit: Oak Ridge National Lab CO2 Heat Pump Water Heater ...

  20. Solar Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heat & Cool » Water Heating » Solar Water Heaters Solar Water Heaters Solar panels heat water that is delivered to a storage tank.| Photo courtesy of David Springer, National Renewable Energy Laboratory Solar panels heat water that is delivered to a storage tank.| Photo courtesy of David Springer, National Renewable Energy Laboratory Solar water heaters -- also called solar domestic hot water systems -- can be a cost-effective way to generate hot water for your home. They can be used in

  1. Solar water heaters | Open Energy Information

    Open Energy Info (EERE)

    Solar water heaters Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)1...

  2. Solar water heaters | Open Energy Information

    Open Energy Info (EERE)

    Solar water heaters (Redirected from - Solar Hot Water) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of...

  3. CO2 Heat Pump Water Heater

    Broader source: Energy.gov (indexed) [DOE]

    CO 2 Heat Pump Water Heater 2014 Building Technologies Office Peer Review Evaporator Kyle ... MarketAudience: Residential electric water heating Key Partners: GE Appliances CRADA ...

  4. Commercial Absorption Heat Pump Water Heater

    Broader source: Energy.gov (indexed) [DOE]

    Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick ... The target market is the hospital, hotel and full service restaurant gas hot water heating ...

  5. Commercial Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heaters Commercial Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Commercial Water Heaters -- v2.0 (96.96 KB) More Documents & Publications

  6. Storage Electric Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Electric Water Heaters Storage Electric Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Water Heaters, Storage Electric -- v2.0 (102.27 KB) More Documents

  7. Storage Gas Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Gas Water Heaters Storage Gas Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Water Heaters, Storage Gas -- v2.0 (106.02 KB) More Documents &

  8. Storage Oil Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Oil Water Heaters Storage Oil Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Water Heaters, Storage Oil -- v2.0 (103.3 KB) More Documents & Publications

  9. Tankless Electric Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Electric Water Heaters Tankless Electric Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Water Heaters, Tankless Electric -- v2.0 (98.91 KB) More Documents

  10. Tankless Gas Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Gas Water Heaters Tankless Gas Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Water Heaters, Tankless Gas -- v1_2 (108.48 KB) More Documents &

  11. Heat Pump Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heat Pump Water Heaters Heat Pump Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards. Heat Pump Water Heaters -- v1.7 (350.5 KB) More Documents &

  12. Field Monitoring Protocol: Heat Pump Water Heaters

    SciTech Connect (OSTI)

    Sparn, B.; Earle, L.; Christensen, D.; Maguire, J.; Wilson, E.; Hancock, E.

    2013-02-01

    This document provides a standard field monitoring protocol for evaluating the installed performance of Heat Pump Water Heaters in residential buildings. The report is organized to be consistent with the chronology of field test planning and execution. Research questions are identified first, followed by a discussion of analysis methods, and then the details of measuring the required information are laid out. A field validation of the protocol at a house near the NREL campus is included for reference.

  13. Clark Public Utilities- Solar Water Heater Rebate

    Office of Energy Efficiency and Renewable Energy (EERE)

    In addition, Clark Public Utilities offers a loan program for eligible solar water heater equipment. For additional information, call Energy Services at (360) 992-3355.

  14. Residential Water Heaters Webinar | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    ...identialwaterheaterwebinar.pdf (1.77 MB) More Documents & Publications Sustainable Energy Resources for Consumers (SERC) - On-Demand Tankless Water Heaters 2014-10-14 Issuance: ...

  15. Solar Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    They are popular in climates prone to freezing temperatures. Illustration of an active, closed loop solar water heater. A large, flat panel called a flat plate collector is ...

  16. Sizing a New Water Heater | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    systems: Tankless or demand-type water heaters Solar water heating system Storage and heat pump (with tank) water heaters. For sizing combination water and space heating systems --...

  17. Sizing a New Water Heater | Department of Energy

    Energy Savers [EERE]

    Heat & Cool Water Heating Sizing a New Water Heater Sizing a New Water Heater Is your water heater the right size for you house? | Photo credit ENERGY STAR Is your water ...

  18. Tankless Demand Water Heater Basics | Department of Energy

    Energy Savers [EERE]

    Water Heating Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the ...

  19. Tankless Coil and Indirect Water Heaters | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    An indirect water heater. An indirect water heater. How does it work? Tankless coil and indirect water heaters use your home's heating system to heat water. Tankless coil and...

  20. Tankless Coil and Indirect Water Heater Basics | Department of...

    Energy Savers [EERE]

    Homes & Buildings Water Heating Tankless Coil and Indirect Water Heater Basics Tankless Coil and Indirect Water Heater Basics August 19, 2013 - 3:03pm Addthis Illustration of ...

  1. Strategy Guideline: Proper Water Heater Selection

    SciTech Connect (OSTI)

    Hoeschele, M.; Springer, D.; German, A.; Staller, J.; Zhang, Y.

    2015-04-01

    This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

  2. Strategy Guideline. Proper Water Heater Selection

    SciTech Connect (OSTI)

    Hoeschele, M.; Springer, D.; German, A.; Staller, J.; Zhang, Y.

    2015-04-09

    This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

  3. The Market - Who Needs Heat Pump Water Heaters? (Journal Article...

    Office of Scientific and Technical Information (OSTI)

    Journal Article: The Market - Who Needs Heat Pump Water Heaters? Citation Details In-Document Search Title: The Market - Who Needs Heat Pump Water Heaters? Heat pump water heaters ...

  4. Covered Product Category: Residential Heat Pump Water Heaters...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heat Pump Water Heaters Covered Product Category: Residential Heat Pump Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance and Federal ...

  5. Adsorption Heat Pump Water Heater | Department of Energy

    Energy Savers [EERE]

    Adsorption Heat Pump Water Heater Adsorption Heat Pump Water Heater Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN DOE Funding: 500,000 Project Term: Oct. 2013 - ...

  6. Absorption Heat Pump Water Heater - 2013 Peer Review | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Absorption Heat Pump Water Heater - 2013 Peer Review Absorption Heat Pump Water Heater - 2013 Peer Review Emerging Technologies Project for the 2013 Building Technologies Office's ...

  7. EERE Success Story-Xergy Develops Breakthrough Water Heater Compressor...

    Office of Environmental Management (EM)

    Xergy Develops Breakthrough Water Heater Compressor EERE Success Story-Xergy Develops Breakthrough Water Heater Compressor September 15, 2015 - 3:41pm Addthis Xergy Inc. and an ...

  8. Energy Cost Calculator for Electric and Gas Water Heaters | Department...

    Office of Environmental Management (EM)

    Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters Vary equipment size, energy cost, hours of operation, and or efficiency level. INPUT ...

  9. Heat Pump Water Heater Using Solid-State Energy Converters

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heat Pump Water Heater Using Solid-State Energy Converters 2016 Building Technologies ... Project Goal: Demonstrate a home water heater product with affordable and reliable ...

  10. Heat Pump Water Heater Using Solid-State Energy Converters

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heat Pump Water Heater Using Solid-State Energy Converters 2015 Building Technologies ... Home Water Heaters with Affordable, Reliable Solid-State Heat Pumps Key Partners: ...

  11. Purchasing Energy-Efficient Residential Solar Water Heaters ...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Solar Water Heaters Purchasing Energy-Efficient Residential Solar Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for residential solar ...

  12. Advanced Hybrid Water-Heater Using Electrochemical Compression...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Bamdad Bahar bamdad.bahar@xergyinc.com Xergy, Inc. Advanced Hybrid Water-Heater Using ... Project Goal: Develop a heat pump water heater utilizing electrochemical ...

  13. Purchasing Energy-Efficient Residential Gas Storage Water Heaters...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Gas Storage Water Heaters Purchasing Energy-Efficient Residential Gas Storage Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for ...

  14. Advanced Hybrid Water-Heater Using Electrochemical Compression...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Hybrid Water-Heater Using Electrochemical Compression (ECC) 2016 Building Technologies ... Key Partners: Project Goal: Develop a heat pump water heater utilizing electrochemical ...

  15. New Residential Water Heater Concept Promises High Efficiency...

    Energy Savers [EERE]

    Residential Water Heater Concept Promises High Efficiency, Lower Cost New Residential Water Heater Concept Promises High Efficiency, Lower Cost August 17, 2016 - 2:20pm Addthis A ...

  16. DOE Publishes Notice of Proposed Rulemaking for Residential Water Heater and Certain Commercial Water Heater Test Procedures

    Broader source: Energy.gov [DOE]

    The Department of Energy has published a notice of proposed rulemaking regarding test procedures for residential water heaters and certain commercial water heaters.

  17. Estimating the Cost and Energy Efficiency of a Solar Water Heater...

    Broader source: Energy.gov (indexed) [DOE]

    Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit...

  18. Tankless or Demand-Type Water Heaters | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    a demand water heater at each hot water outlet. ENERGY STAR estimates that a typical family can save 100 or more per year with an ENERGY STAR qualified tankless water heater....

  19. Selecting a New Water Heater | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    or demand-type water heaters heat water directly without the use of a storage tank Heat pump water heaters move heat from one place to another instead of generating heat...

  20. Covered Product Category: Commercial Gas Water Heaters

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including commercial gas water heaters, which are covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  1. What to expect from a batch solar water heater

    SciTech Connect (OSTI)

    Stickney, B.

    1984-01-01

    Batch solar water heaters are becoming more popular because of their low initial cost and simplicity of operation. Batch type water heaters have the following features in common: a water tank or tanks, an insulated tank enclosure, a glazed collecter surface, and a reflector system. The advantages of this type of solar water heater are discussed.

  2. Consumer Water Heater, UEF - v1.0 | Department of Energy

    Office of Environmental Management (EM)

    Water Heater, UEF - v1.0 Consumer Water Heater, UEF - v1.0 Consumer Water Heater, UEF - v1.0 (502.56 KB) More Documents & Publications Tankless Gas Water Heaters Heat Pump Water ...

  3. Xergy Ships First Breakthrough Water Heater Compressor to GE...

    Energy Savers [EERE]

    Xergy Ships First Breakthrough Water Heater Compressor to GE Xergy Ships First Breakthrough Water Heater Compressor to GE September 15, 2015 - 3:41pm Addthis Xergy Inc. and GE...

  4. Measure Guideline. Transitioning to a Tankless Water Heater

    SciTech Connect (OSTI)

    Brozyna, K.; Rapport, A.

    2012-09-01

    This measure guideline provides information to help residential builders and retrofitters with the design, specification, selection, implementation, installation, and maintenance issues of transitioning from tank-type water heaters to tankless water heaters.

  5. Heat Pump Water Heater using Solid-State Energy Converters |...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heater using Solid-State Energy Converters Heat Pump Water Heater using Solid-State Energy Converters Sheetak will work on developing a full scale prototype of its low cost ...

  6. GeoSprings Hybrid Water Heater - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    GeoSprings Hybrid Water Heater Oak Ridge National Laboratory

    Oak Ridge National Laboratory&39;s facility tests several water heaters at one time. Because of ORNL&39;s ...

  7. Blue Ridge Electric Cooperative- Residential Water Heater Rebate

    Broader source: Energy.gov [DOE]

    Blue Ridge Electric Cooperative offers up to $300 for the purchase of an electric water heater. The rebate amount varies based on the size of the water heater purchased.

  8. Sizing a New Water Heater | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Is your water heater the right size for you house? | Photo credit ENERGY STAR Is your water heater the right size for you house? | Photo credit ENERGY STAR A properly sized ...

  9. U.S. Virgin Islands- Solar Water Heater Rebate Program

    Broader source: Energy.gov [DOE]

    A household can receive a maximum of two solar water heater rebates. Rebate amounts vary slightly based upon installed equipment. Rebates will be $1,250 for solar water heaters with an OG-300 rat...

  10. Savings Project: Insulate Your Water Heater Tank | Department...

    Energy Savers [EERE]

    Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Addthis Project Level medium Energy Savings 20-45 annually Time to Complete 1.5 hours Overall Cost 30 ...

  11. ENERGY STAR Residential Water Heaters to Save Americans Up to...

    Energy Savers [EERE]

    STAR Residential Water Heaters to Save Americans Up to 823 Million in the Next Five Years ENERGY STAR Residential Water Heaters to Save Americans Up to 823 Million in the Next ...

  12. Technology Solutions Case Study: Heat Pump Water Heater Retrofit

    SciTech Connect (OSTI)

    none,

    2012-08-01

    In this project, Pacific Northwest National Laboratory studied heat pump water heaters, an efficient, cost-effective alternative to traditional electric resistance water heaters that can improve energy efficiency by up to 62%.

  13. NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-02-01

    NREL evaluates energy savings potential of heat pump water heaters in homes throughout all U.S. climate zones.

  14. List of Water Heaters Incentives | Open Energy Information

    Open Energy Info (EERE)

    Heaters Incentives Jump to: navigation, search The following contains the list of 975 Water Heaters Incentives. CSV (rows 1-500) CSV (rows 501-975) Incentive Incentive Type Place...

  15. Consumer Water Heater, UEF - v1.0 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heater, UEF - v1.0 Consumer Water Heater, UEF - v1.0 Consumer Water Heater, UEF - v1.0 (502.56 KB) More Documents & Publications Tankless Gas Water Heaters Heat Pump Water Heaters Storage Gas Water Heaters

  16. Expert Meeting Report: Recommendations for Applying Water Heaters...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems A. Rudd, K. Ueno, D. Bergey, R. Osser Building Science Corporation June 2012 i ...

  17. Regional Variation in Residential Heat Pump Water Heater Performance...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Performance of Water Heating Systems Building America Technology Solutions for New and Existing Homes: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, ...

  18. Water Heater Enforcement Policy Statement | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heater Enforcement Policy Statement Water Heater Enforcement Policy Statement October 2, 2015 This enforcement policy statement explains DOE's policy with respect to the enforcement of certification requirements and compliance with standards with respect to consumer water heaters and residential-duty commercial water heating equipment during the interim period between July 13, 2015, and the publication of a conversion factor final rule. Enforcement Policy Statement - WH.pdf (74.46 KB) More

  19. Efficient Residential Water Heaters Webinar | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Pilot Projects » Efficient Residential Water Heaters Webinar Efficient Residential Water Heaters Webinar On Feb. 22, 2011, Jerone Gagliano, director of Energy Engineering Performance Systems Development, presented a Webinar about residential water heating technology and how to choose the right water heater. It's one of the presentations in a series of Sustainable Energy Resources for Consumers Webinars sponsored by the U.S. Department of Energy (DOE) Weatherization Assistance Program. View the

  20. Tankless Gas Water Heater Performance - Building America Top Innovation |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Tankless Gas Water Heater Performance - Building America Top Innovation Tankless Gas Water Heater Performance - Building America Top Innovation This photo shows a hot water heater measuring device mounted on the outside of a building wall. As improved thermal enclosures dramatically reduce heating and cooling loads, the water heating load continues to grow in importance. This Top Innovations profile describes Building America field testing by IBACOS that shed light on

  1. Measure Guideline: Transitioning to a Tankless Water Heater

    SciTech Connect (OSTI)

    Brozyna, K.; Rapport, A.

    2012-09-01

    This Measure Guideline provides information to help residential builders and retrofitters with the design, specification, selection, implementation, installation, and maintenance issues of transitioning from tank-type water heaters to tankless water heaters. The report compares the differences between tankless and tank-type water heaters, highlighting the energy savings that can be realized by adopting tankless water heaters over tank-type water heaters. Selection criteria and risks discussed include unit sizing and location, water distribution system, plumbing line length and diameter, water quality, electrical backup, and code issues. Cost and performance data are provided for various types of tankless and tank-type water heaters, both natural gas fired and electric. Also considered are interactions between the tankless water heater and other functional elements of a house, such as cold water supply and low-flow devices. Operating costs and energy use of water distribution systems for single- and two-story houses are provided, along with discussion of the various types of distribution systems that can be used with tankless water heaters. Finally, details to prepare for proper installation of a tankless water heater are described.

  2. CO2 Heat Pump Water Heater

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    CO 2 Heat Pump Water Heater 2016 Building Technologies Office Peer Review Kyle Gluesenkamp, gluesenkampk@ornl.gov Oak Ridge National Laboratory Evaporator 2 Project Summary Timeline: Start date: Oct 1, 2009 Planned end date: Sep 30, 2016 Key Milestones 1. Go/No-Go: Price premium <$750 compared to baseline HFC HPWH; FY15Q2 (MET) 2. Go/No-Go: EF>2.0 and FHR>50 gallon to meet ENERGY STAR qualification criteria; FY14Q4 (MET) Budget: Total DOE to Date: $2,367k Total Project: $2,435k Key

  3. Estimating the Cost and Energy Efficiency of a Solar Water Heater |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can usually save you

  4. Monitoring SERC Technologies: On-Demand Tankless Water Heaters | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Weatherization Assistance Program » Pilot Projects » Monitoring SERC Technologies: On-Demand Tankless Water Heaters Monitoring SERC Technologies: On-Demand Tankless Water Heaters On Oct. 4, 2011, Ethan MacCormick, VP for Services to Energy Businesses at Performance Systems Development, presented a Webinar about On-Demand Tankless Water Heaters and how to properly monitor their installation. View the webinar presentation. More Information Some resources and tools mentioned in the

  5. Purchasing Energy-Efficient Commercial Gas Water Heaters | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Gas Water Heaters Purchasing Energy-Efficient Commercial Gas Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for commercial gas water heaters (CWHs), a product category covered by ENERGY STAR efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR-qualified products or FEMP-designated products in all product categories covered by these programs and in any acquisition actions that are not specifically

  6. Purchasing Energy-Efficient Residential Gas Storage Water Heaters |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Gas Storage Water Heaters Purchasing Energy-Efficient Residential Gas Storage Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for residential gas storage water heaters, a product category covered by ENERGY STAR efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR-qualified products or FEMP-designated products in all product categories covered by these programs and in any acquisition

  7. Commercial Absorption Heat Pump Water Heater | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Absorption Heat Pump Water Heater Commercial Absorption Heat Pump Water Heater Credit: Oak Ridge National Laboratory Credit: Oak Ridge National Laboratory Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN Partner: A.O. Smith Inc. - Milwaukee, WI DOE Funding: $2,000,000 Cost Share: Provided by CRADA partners Project Term: October 1, 2013 - September 30, 2016 Project Objective The objective of this project is to develop a gas-fired absorption heat pump water heater for the commercial

  8. Which Water Heater Is Right for You? | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Which Water Heater Is Right for You? Which Water Heater Is Right for You? March 5, 2015 - 11:07am Addthis Investing in a more energy efficient water heater can save you money in the long run. | Photo courtesy of Sarah Gerrity, U.S. Department of Energy Investing in a more energy efficient water heater can save you money in the long run. | Photo courtesy of Sarah Gerrity, U.S. Department of Energy Paige Terlip Paige Terlip Former Communicator, National Renewable Energy Laboratory What does this

  9. Residential Absorption Heat Pump Water Heater | Department of...

    Broader source: Energy.gov (indexed) [DOE]

    Oak Ridge National Laboratory (ORNL) is developing and promoting the market introduction of a residential absorption heat pump water heater that would use 40% less energy annually ...

  10. Covered Product Category: Residential Electric Resistance Water Heaters

    Broader source: Energy.gov [DOE]

    FEMP sets federal efficiency requirements and provides acquisition guidance across a variety of product categories, including residential electric resistance water heaters.

  11. Build-it-yourself solar water heater: reduce electric use

    SciTech Connect (OSTI)

    Not Available

    1982-01-01

    Drawings and instructions for a simple breadbox-style solar water heater are presented. This booklet is a step-by-step guide to building a solar water heater for approximately 15 percent of the cost of most commercially-installed systems. This system does not provide as much energy as the commercially available systems. (MHR)

  12. Conventional Storage Water Heater Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating » Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On top of the tank are two thin pipes; one pipe is the hot water outlet, and the other is the cold water inlet. A large pipe in the middle is called a vent pipe. A pressure/temperature relief valve is also on top of the tank and is connected to an open pipe that runs down the side of the tank. Another

  13. Heat Pump Water Heater Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating » Heat Pump Water Heater Basics Heat Pump Water Heater Basics August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a larger one on the bottom. In the top chamber are a fan, a cylindrical compressor, and an evaporator that runs along the inside of the chamber. Jutting out from the exterior of the bottom chamber is a temperature and pressure relief valve. This valve has a tube called a hot water

  14. Low-Cost Batch Solar Water Heater Research and Development Project: results from extended field monitoring. Final report, January 1, 1983-May 15, 1983

    SciTech Connect (OSTI)

    Stickney, B.L.

    1984-02-01

    This report contains the results of a four month field test and evaluation of a 30 gallon inverted batch solar water heater known as the Bottomgainer. It was installed on a residence in Santa Fe and monitored with automatic data recorders including solar radiation meter, dual channel Btu meters, water meter and 16 channel strip chart temperature recorder. Average values of heat gain, heat loss, collection efficiency, solar heating fraction and cash benefits are presented and discussed.

  15. Utilization of Heat Pump Water Heaters for Load Management

    SciTech Connect (OSTI)

    Boudreaux, Philip R; Jackson, Roderick K; Munk, Jeffrey D; Gehl, Anthony C; Lyne, Christopher T

    2014-01-01

    The Energy Conservation Standards for Residential Water Heaters require residential electric storage water heaters with volumes larger than 55 gallons to have an energy factor greater than 2.0 after April 2015. While this standard will significantly increase the energy efficiency of water heaters, large electric storage water heaters that do not use heat pump technologies may no longer be available. Since utilities utilize conventional large-volume electric storage water heaters for thermal storage in demand response programs, there is a concern that the amended standard will significantly limit demand response capacity. To this end, Oak Ridge National Laboratory partnered with the Tennessee Valley Authority to investigate the load management capability of heat pump water heaters that meet or exceed the forthcoming water heater standard. Energy consumption reduction during peak periods was successfully demonstrated, while still meeting other performance criteria. However, to minimize energy consumption, it is important to design load management strategies that consider the home s hourly hot water demand so that the homeowner has sufficient hot water.

  16. Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California

    SciTech Connect (OSTI)

    Lu, Alison; McMahon, James; Masanet, Eric; Lutz, Jim

    2008-08-13

    Residential water heating is a large source of energy use in California homes. This project took a life cycle approach to comparing tank and tankless water heaters in Northern and Southern California. Information about the life cycle phases was calculated using the European Union's Methodology study for EcoDesign of Energy-using Products (MEEUP) and the National Renewable Energy Laboratory's Life Cycle Inventory (NREL LCI) database. In a unit-to-unit comparison, it was found that tankless water heaters would lessen impacts of water heating by reducing annual energy use by 2800 MJ/year (16% compared to tank), and reducing global warming emissions by 175 kg CO2 eqv./year (18% reduction). Overall, the production and combustion of natural gas in the use phase had the largest impact. Total waste, VOCs, PAHs, particulate matter, and heavy-metals-to-air categories were also affected relatively strongly by manufacturing processes. It was estimated that tankless water heater users would have to use 10 more gallons of hot water a day (an increased usage of approximately 20%) to have the same impact as tank water heaters. The project results suggest that if a higher percentage of Californians used tankless water heaters, environmental impacts caused by water heating would be smaller.

  17. Predictive Control of Hot Water Heaters - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Publication Full Report on Heat Pump Water Heaters (15,810 KB) Technology Marketing Summary Water heating in residential homes can account for as much as 15% of total energy use. ...

  18. Enforcement Policy Statement Consumer Water Heaters and Certain...

    Broader source: Energy.gov (indexed) [DOE]

    Consumer Water Heaters and Certain Commercial Water Heating Equipment Issued: October 2, 2015 As required by 42 U.S.C. 6295(e)(5)(B), the U.S. Department of Energy (DOE) ...

  19. A Combined Water Heater Dehumidifier and Cooler (WHDC)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Combined Water Heater Dehumidifier and Cooler (WHDC) 2016 Building Technologies Office ... Project Outcome: - Develop a low-cost gas-fired water heat pump to meet the DOE MYPP 2020 ...

  20. Marshall Municipal Utilities- Solar Thermal Water Heater Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    To invest in a renewable resource, consider an ENERGY STAR Solar Thermal Water Heater and use free energy from the sun to heat your water. Marshall Municipal Utilities (MMU) offers rebates of $20...

  1. Max Tech Electric Heat Pump Water Heater with Lower GWP Halogenated...

    Energy Savers [EERE]

    Max Tech Electric Heat Pump Water Heater with Lower GWP Halogenated Refrigerant Max Tech Electric Heat Pump Water Heater with Lower GWP Halogenated Refrigerant Information flow ...

  2. Solar Water Heater Roadmap Leads Path to Market Expansion (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-09-01

    Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace.

  3. Advanced Hybrid Water Heater using Electrochemical Compressor | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Hybrid Water Heater using Electrochemical Compressor Advanced Hybrid Water Heater using Electrochemical Compressor Xergy is using its Electro Chemical Compression (ECC) technology to operate a heat pump cycle using water as the working fluid<br /> Image: Xergy Xergy is using its Electro Chemical Compression (ECC) technology to operate a heat pump cycle using water as the working fluid Image: Xergy Xergy's technology has the potential to move away from vapor compression

  4. Comparative performance indices for solar batch water heaters

    SciTech Connect (OSTI)

    Stickney, B.L.; Aaboe, E.H.

    1981-01-01

    A simple method is developed to allow direct comparison of various solar batch water heaters. Certain system variables must be determined by calculation or measurement which may vary with season. These include Thermal Efficiency of Collection, Tank R value, Collector Surface to Tank Volume Ratio, Clear Day Collection Period in Hours, System Cost, and Installed Solar Heatings Fraction (optional). These variables are used to compute any one of four performance indices. This method allows a valid comparison not only between various solar batch water heaters but between other types of solar water heaters as well. This system may be used by consumers or designers to choose the most cost and performance effective options.

  5. Aiken Electric Cooperative Inc- Residential Water Heater Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Aiken Electric Cooperative offers residential members rebates for installing high-efficiency electric water heaters and/or timers in their homes. Customers have four rebate options: 

  6. Rock Hill Utilities- Water Heater and Heat Pump Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Through the SmartChoice program, Rock Hill Utilities offers rebates for water heater and heat pump replacements. Information on financing for heat pumps can also be found on the web site listed...

  7. Performance comparison of several passive solar water heaters

    SciTech Connect (OSTI)

    Stickney, B.L.; Nagy, C.

    1980-01-01

    Three .076 m/sup 3/ (20 gal.) batch water heaters were constructed for the purpose of side by side testing. The test models included an Inverted Batch Water Heater, a Greenhouse Integrated Skylight Heater, and a typical Breadbox Batch Heater. These designs were chosen because of their low initial cost, simple construction, ease of freeze protection, uncomplicated operation and heating effectiveness. The results of our testing show that our test models produced 35 to 70/sup 0/C (95 to 158/sup 0/F) average water temperatures with average collection efficiencies of about 34%. Materials costs for each of these systems were $200 to $400. These systems were tested side by side during periods of both low and high thermal demand, both with and without a selective surface foil on the absorber surfaces.

  8. Heat Pump Water Heaters and American Homes: A Good Fit?

    SciTech Connect (OSTI)

    Franco, Victor; Lekov, Alex; Meyers, Steve; Letschert, Virginie

    2010-05-14

    Heat pump water heaters (HPWHs) are over twice as energy-efficient as conventional electric resistance water heaters, with the potential to save substantial amounts of electricity. Drawing on analysis conducted for the U.S. Department of Energy's recently-concluded rulemaking on amended standards for water heaters, this paper evaluates key issues that will determine how well, and to what extent, this technology will fit in American homes. The key issues include: 1) equipment cost of HPWHs; 2) cooling of the indoor environment by HPWHs; 3) size and air flow requirements of HPWHs; 4) performance of HPWH under different climate conditions and varying hot water use patterns; and 5) operating cost savings under different electricity prices and hot water use. The paper presents the results of a life-cycle cost analysis of the adoption of HPWHs in a representative sample of American homes, as well as national impact analysis for different market share scenarios. Assuming equipment costs that would result from high production volume, the results show that HPWHs can be cost effective in all regions for most single family homes, especially when the water heater is not installed in a conditioned space. HPWHs are not cost effective for most manufactured home and multi-family installations, due to lower average hot water use and the water heater in the majority of cases being installed in conditioned space, where cooling of the indoor environment and size and air flow requirements of HPWHs increase installation costs.

  9. WHAM: Simplified tool for calculating water heater energy use

    SciTech Connect (OSTI)

    Lutz, J.D.; Whitehead, C.D.; Lekov, A.B.; Rosenquist, G.J.; Winiarski, D.W.

    1999-07-01

    Water heating comprises a significant portion of residential energy consumption--17% in the US, according to the residential energy consumption survey (RECS) (EIA 1995). For such a significant energy end use, energy analysts need a method to quickly and reliably assess current and future energy requirements for a variety of conservation policies and programs. To fill this need, the water heater analysis model (WHAM) was developed as a simple energy equation that accounts for different operating conditions and water heater characteristics when calculating energy consumption. The results of WHAM are compared to the results of detailed water heater simulation programs and show a high level of accuracy in estimating energy consumption. WHAM energy calculations are based on assumptions that account for a variety of field conditions and water heater types. By including seven parameters--recovery efficiency (RE), standby heat loss coefficient (UA), rated input power (Pon), average daily hot water draw volume, inlet water temperature, thermostat setting, and air temperature around the water heater--WHAM provides an accurate estimate of energy consumption in the majority of cases.

  10. Water inflow into boreholes during the Stripa heater experiments

    SciTech Connect (OSTI)

    Nelson, P.H.; Rachiele, R.; Remer, J.S.; Carlsson, H.

    1981-04-01

    During the operation of three in-situ heater experiments at Stripa, Sweden, groundwater flowed into many of the instrumentation and heater boreholes. These flows were recovered and measured routinely. The records of water inflow indicate two origins: inflow attributed to local hydrological pressure gradients, and water migration from cracks closing under the rapidly increasing, thermal-induced stress changes. The latter component appeared as a main pulse that occurred when the heaters were turned on, and lasted about 30 to 40 days, steadily declining over the next several months, and decreasing sharply when heater power was decreased or stopped. The magnitude of the total inflow per hole ranged over more than five decades, from 0.1 to over 10,000 liters over the 500 to 600 day time periods. When plotted against the logarithm of total volume, the frequency distribution displays a normal curve dependence with a mean of approximately 10 liters. Of this amount, 1 to 2 liters of flow into 38-mm-diam boreholes accompanied an increase in applied heat load. These amounts are compatible with rock porosities of a fraction of one percent. Inflow into the 3.6 and 5.0 kW heater holes peaked within 3 to 6 days after heater turn on, then declined to zero inflow, with no further inflow measured for the remainder of the experiments. In the heater holes of the time-scaled experiment, which operated at 1.125 kW or less, the initial pulse of inflow took much longer to decay, and 7 of 8 heater holes continued to flow throughout the experiment. The packing off and isolation of a borehole some 40 m distant in the ventilation drift dramatically increased the inflow into the heater holes in one of the three heater experiments. This demonstrated the existence of permeable flow paths among a number of boreholes. The records of water inflow demonstrate the need for a thorough understanding of the nature of fluid flow and storage in fractured crystalline rock.

  11. Buildings Energy Data Book: 5.4 Water Heaters

    Buildings Energy Data Book [EERE]

    2 Water Heater Stock for Residential Buildings, By Storage Type Small (30 gallons or less) 17.1 17% 1.4 14% 18.5 17% Medium (31 to 49 gallons) 52.4 53% 2.4 24% 54.8 50% Large (50 gallons or more) 27.1 27% 2.8 27% 29.9 27% Tankless water heater 1.1 1% 0.2 2% 1.3 1% No Separate Water Heater 1.9 2% 3.4 33% 5.3 5% Total (1) 99.6 100% 10.2 100% 109.8 100% Note(s): Souce(s): Number and Percent of Households in 2005 Used by One Unit Used by Multiple Units Total According to RECS, 1.1 million households

  12. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    SciTech Connect (OSTI)

    Sparn, B.; Hudon, K.; Christensen, D.

    2011-09-01

    This report discusses how a significant opportunity for energy savings is domestic hot water heating, where an emerging technology has recently arrived in the U.S. market: the residential integrated heat pump water heater. A laboratory evaluation is presented of the five integrated HPWHs available in the U.S. today.

  13. Buildings Energy Data Book: 5.4 Water Heaters

    Buildings Energy Data Book [EERE]

    3 Water Heater Manufacturer Market Shares 2006 2008 A.O. Smith/State Industries 23% 46% Rheem Manufacturing 37% 37% Bradford-White 14% 13% American Water Heater 14% (1) Others 12% 4% Total 100% 100% Total Units Shipped (2) Note(s): Source(s): 9,446,076 8,190,043 1) Included in A.O. Smith/State Industries. 2) Excludes exports. Appliance Magazine, A Portrait of the U.S. Appliance Industry, Sept. 2007, p. 63 for 2006; Appliance Magazine, U.S. Appliance Industry: Market Share, Life Expectancy &

  14. Estimating the Cost and Energy Efficiency of a Solar Water Heater...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater March 2, 2015 - 3:09pm Addthis Solar water...

  15. Development of a Market Optimized Condensing Gas Water Heater

    SciTech Connect (OSTI)

    Peter Pescatore

    2006-01-11

    This program covered the development of a market optimized condensing gas water heater for residential applications. The intent of the program was to develop a condensing design that minimized the large initial cost premium associated with traditional condensing water heater designs. Equally important was that the considered approach utilizes design and construction methods that deliver the desired efficiency without compromising product reliability. Standard condensing water heater approaches in the marketplace utilize high cost materials such as stainless steel tanks and heat exchangers as well as expensive burner systems to achieve the higher efficiencies. The key in this program was to develop a water heater design that uses low-cost, available components and technologies to achieve higher efficiency at a modest cost premium. By doing this, the design can reduce the payback to a more reasonable length, increasing the appeal of the product to the marketplace. Condensing water heaters have been in existence for years, but have not been able to significantly penetrate the market. The issue has typically been cost. The high purchase price associated with existing condensing water heaters, sometimes as much as $2000, has been a very difficult hurdle to overcome in the marketplace. The design developed under this program has the potential to reduce the purchase price of this condensing design by as much as $1000 as compared to traditional condensing units. The condensing water heater design developed over the course of this program led to an approach that delivered the following performance attributes: 90%+ thermal efficiency; 76,000 Btu/hr input rate in a 50 gallon tank; First hour rating greater than 180 gph; Rapid recovery time; and Overall operating condition well matched to combination heat and hot water applications. Over the final three years of the program, TIAX worked very closely with A.O. Smith Water Products Company as our commercial partner to optimize

  16. Covered Product Category: Residential Gas Storage Water Heaters

    Office of Energy Efficiency and Renewable Energy (EERE)

    FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  17. Covered Product Category: Residential Gas Storage Water Heaters

    Office of Energy Efficiency and Renewable Energy (EERE)

    FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  18. Covered Product Category: Residential Heat Pump Water Heaters

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including residential heat pump water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  19. Purchasing Energy-Efficient Commercial Gas Water Heaters

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Federal Energy Management Program (FEMP) provides acquisition guidance for commercial gas water heaters (CWHs), a product category covered by ENERGY STAR efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR-qualified products or FEMP-designated products in all product categories covered by these programs and in any acquisition actions that are not specifically exempted by law.

  20. Demand Response Performance of GE Hybrid Heat Pump Water Heater

    SciTech Connect (OSTI)

    Widder, Sarah H.; Parker, Graham B.; Petersen, Joseph M.; Baechler, Michael C.

    2013-07-01

    This report describes a project to evaluate and document the DR performance of HPWH as compared to ERWH for two primary types of DR events: peak curtailments and balancing reserves. The experiments were conducted with GE second-generation “Brillion”-enabled GeoSpring hybrid water heaters in the PNNL Lab Homes, with one GE GeoSpring water heater operating in “Standard” electric resistance mode to represent the baseline and one GE GeoSpring water heater operating in “Heat Pump” mode to provide the comparison to heat pump-only demand response. It is expected that “Hybrid” DR performance, which would engage both the heat pump and electric elements, could be interpolated from these two experimental extremes. Signals were sent simultaneously to the two water heaters in the side-by-side PNNL Lab Homes under highly controlled, simulated occupancy conditions. This report presents the results of the evaluation, which documents the demand-response capability of the GE GeoSpring HPWH for peak load reduction and regulation services. The sections describe the experimental protocol and test apparatus used to collect data, present the baselining procedure, discuss the results of the simulated DR events for the HPWH and ERWH, and synthesize key conclusions based on the collected data.

  1. Buildings Energy Data Book: 5.4 Water Heaters

    Buildings Energy Data Book [EERE]

    4 Water Heater Stock for Commercial Buildings, By Fuel Type Fuel Type Electric 41% Natural Gas 31% Fuel Oil 2% Propane/LPG 3% District Heat 1% No Water Heating 25% Note(s): Souce(s): Percent of Buildings in 2003 (1) (1) Percentages add to 103% because some buildings use more than one fuel for water heating. EIA, 2003 Commercial Buildings Energy Consumption Survey: Buildings Characteristics, June 2006, Table B31, p. 175

  2. Exparte Memo: 4-26-16 Meeting on Test Procedures for Water Heaters...

    Office of Environmental Management (EM)

    Exparte Memo: 4-26-16 Meeting on Test Procedures for Water Heaters, EERE-2015-BT-TP-0007-0002 Exparte Memo: 4-26-16 Meeting on Test Procedures for Water Heaters, ...

  3. HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...

    Energy Savers [EERE]

    HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This ...

  4. Evaluation of the Demand Response Performance of Electric Water Heaters

    SciTech Connect (OSTI)

    Mayhorn, Ebony T.; Widder, Sarah H.; Parker, Steven A.; Pratt, Richard M.; Chassin, Forrest S.

    2015-03-17

    The purpose of this project is to verify or refute many of the concerns raised by utilities regarding the ability of large tank HPWHs to perform DR by measuring the performance of HPWHs compared to ERWHs in providing DR services. perform DR by measuring the performance of HPWHs compared to ERWHs in providing DR services. This project was divided into three phases. Phase 1 consisted of week-long laboratory experiments designed to demonstrate technical feasibility of individual large-tank HPWHs in providing DR services compared to large-tank ERWHs. In Phase 2, the individual behaviors of the water heaters were then extrapolated to a population by first calibrating readily available water heater models developed in GridLAB-D simulation software to experimental results obtained in Phase 1. These models were used to simulate a population of water heaters and generate annual load profiles to assess the impacts on system-level power and residential load curves. Such population modeling allows for the inherent and permanent load reduction accomplished by the more efficient HPWHs to be considered, in addition to the temporal DR services the water heater can provide by switching ON or OFF as needed by utilities. The economic and emissions impacts of using large-tank water heaters in DR programs are then analyzed from the utility and consumer perspective, based on National Impacts Analysis in Phase 3. Phase 1 is discussed in this report. Details on Phases 2 and 3 can be found in the companion report (Cooke et al. 2014).

  5. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    SciTech Connect (OSTI)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

  6. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    SciTech Connect (OSTI)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

  7. Residential Gas-Fired Adsorption Heat Pump Water Heater | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Gas-Fired Adsorption Heat Pump Water Heater Residential Gas-Fired Adsorption Heat Pump Water Heater Gas-fired adsorption heat pump water heater prototype. Image credit: Oak Ridge National Laboratory. Gas-fired adsorption heat pump water heater prototype. Image credit: Oak Ridge National Laboratory. Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN DOE Funding: $310,000 Project Term: October 1, 2013 - September 30, 2016 Funding Type: Annual Operating Plan (AOP) PROJECT

  8. Diagnosis of Solar Water Heaters Using Solar Storage Tank Surface Temperature Data: Preprint

    SciTech Connect (OSTI)

    Burch, J.; Magnuson, L.; Barker, G.; Bullwinkel, M.

    2009-04-01

    Study of solar water heaters by using surface temperature data of solar storage tanks to diagnose proper operations.

  9. Field Performance of Heat Pump Water Heaters in the Northeast

    SciTech Connect (OSTI)

    Shapiro, C.; Puttagunta, S.

    2013-08-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring(tm), A.O. Smith Voltex(r), and Stiebel Eltron Accelera(r)300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  10. Solar Water Heaters | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    The batch collector is a large box holding a tank and covered with a glaze that faces the sun. Water is heated in this tank, and another pipe takes the heated water from the batch...

  11. SMUD- Solar Water Heater Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Sacramento Municipal Utility District's (SMUD) Solar Domestic Hot Water Program provides rebates and/or loan financing to customers who install solar water heating systems. The amount of the...

  12. Advanced Hybrid Water Heater using Electrochemical Compressor...

    Broader source: Energy.gov (indexed) [DOE]

    cycle using water as the working fluid
    Image: Xergy Xergy is using its Electro Chemical Compression (ECC) technology to operate a heat pump cycle using water as the working ...

  13. Assessment of Unglazed Solar Domestic Water Heaters

    SciTech Connect (OSTI)

    Burch, J.; Salasovich, J.; Hillman, T.

    2005-12-01

    Conference paper investigating cost-performance tradeoffs in replacing glazed collectors with unglazed collectors in solar domestic water heating systems.

  14. Recovery Act: Water Heater ZigBee Open Standard Wireless Controller

    SciTech Connect (OSTI)

    Butler, William P.; Buescher, Tom

    2014-04-30

    The objective of Emerson's Water Heater ZigBee Open Standard Wireless Controller is to support the DOE's AARA priority for Clean, Secure Energy by designing a water heater control that levels out residential and small business peak electricity demand through thermal energy storage in the water heater tank.

  15. Solar Water Heaters and the Economy

    Broader source: Energy.gov [DOE]

    One Coloradan examines the costs and benefits of passive versus conventional water heating systems - and it's effects on property value in the long-term.

  16. Salem Electric- Solar Water Heater Rebate

    Office of Energy Efficiency and Renewable Energy (EERE)

    Salem Electric residential customers with electric water heating are eligible for a $600 rebate through Salem's Bright Way program. A program brochure with details is available on the program...

  17. Model for Aggregated Water Heater Load Using Dynamic Bayesian Networks

    SciTech Connect (OSTI)

    Vlachopoulou, Maria; Chin, George; Fuller, Jason C.; Lu, Shuai; Kalsi, Karanjit

    2012-07-19

    The transition to the new generation power grid, or smart grid, requires novel ways of using and analyzing data collected from the grid infrastructure. Fundamental functionalities like demand response (DR), that the smart grid needs, rely heavily on the ability of the energy providers and distributors to forecast the load behavior of appliances under different DR strategies. This paper presents a new model of aggregated water heater load, based on dynamic Bayesian networks (DBNs). The model has been validated against simulated data from an open source distribution simulation software (GridLAB-D). The results presented in this paper demonstrate that the DBN model accurately tracks the load profile curves of aggregated water heaters under different testing scenarios.

  18. PERFORMANCE IMPROVEMENTS IN COMMERCIAL HEAT PUMP WATER HEATERS USING CARBON DIOXIDE

    SciTech Connect (OSTI)

    BOWERS C.D.; ELBEL S.; PETERSEN M.; HRNJAK P.S.

    2011-07-01

    Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82?ºC (180?ºF), as required by sanitary codes in the U.S.(Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20%.

  19. Electric Water Heater Modeling and Control Strategies for Demand Response

    SciTech Connect (OSTI)

    Diao, Ruisheng; Lu, Shuai; Elizondo, Marcelo A.; Mayhorn, Ebony T.; Zhang, Yu; Samaan, Nader A.

    2012-07-22

    Abstract Demand response (DR) has a great potential to provide balancing services at normal operating conditions and emergency support when a power system is subject to disturbances. Effective control strategies can significantly relieve the balancing burden of conventional generators and reduce investment on generation and transmission expansion. This paper is aimed at modeling electric water heaters (EWH) in households and tests their response to control strategies to implement DR. The open-loop response of EWH to a centralized signal is studied by adjusting temperature settings to provide regulation services; and two types of decentralized controllers are tested to provide frequency support following generator trips. EWH models are included in a simulation platform in DIgSILENT to perform electromechanical simulation, which contains 147 households in a distribution feeder. Simulation results show the dependence of EWH response on water heater usage . These results provide insight suggestions on the need of control strategies to achieve better performance for demand response implementation. Index Terms Centralized control, decentralized control, demand response, electrical water heater, smart grid

  20. Buildings Energy Data Book: 5.4 Water Heaters

    Buildings Energy Data Book [EERE]

    1 Water Heater Stock for Residential Buildings, By Fuel Type Electric Natural Gas Fuel Oil Propane/LPG Other 0.2 0.2% Total (1) Note(s): Souce(s): According to RECS, 1.1 million households did not use hot water.The total only includes those households that used hot water. EIA, Residential Energy Consumption Survey 2005, Table HC 2.8, June 2008. 4.0 3.6% 4.0 3.6% 110.0 100.0% Households in 2005 (millions) Percent 43.1 39.2% 58.7 53.4%

  1. ISSUANCE 2015-08-14: Energy Conservation Program for Consumer Products: Definitions and Standards for Grid-Enabled Water Heaters

    Broader source: Energy.gov [DOE]

    Energy Conservation Program for Consumer Products: Definitions and Standards for Grid-Enabled Water Heaters

  2. Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers

    SciTech Connect (OSTI)

    Lekov, Alex; Franco, Victor; Meyers, Steve; Thompson, Lisa; Letschert, Virginie

    2010-11-24

    The U.S. Department of Energy (DOE) recently completed a rulemaking process in which it amended the existing energy efficiency standards for residential water heaters. A key factor in DOE?s consideration of new standards is the economic impacts on consumers. Determining such impacts requires a comparison of the additional first cost of energy efficiency design options with the savings in operating costs. This paper describes the method used to conduct the life-cycle cost (LCC) and payback period analysis for gas and electric storage water heaters. It presents the estimated change in LCC associated with more energy-efficient equipment, including heat pump electric water heaters and condensing gas water heaters, for a representative sample of U.S. homes. The study included a detailed accounting of installation costs for the considered design options, with a focus on approaches for accommodating the larger dimensions of more efficient water heaters. For heat pump water heaters, the study also considered airflow requirements, venting issues, and the impact of these products on the indoor environment. The results indicate that efficiency improvement relative to the baseline design reduces the LCC in the majority of homes for both gas and electric storage water heaters, and heat pump electric water heaters and condensing gas water heaters provide a lower LCC for homes with large rated volume water heaters.

  3. WPN 00-5: Approval of Replacement Refrigerators and Electric Water Heaters

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    as Allowable Weatherization Measures | Department of Energy 0-5: Approval of Replacement Refrigerators and Electric Water Heaters as Allowable Weatherization Measures WPN 00-5: Approval of Replacement Refrigerators and Electric Water Heaters as Allowable Weatherization Measures Effective: Oct. 6, 2000 Provides states with the approval to include refrigerator and electric water heater replacements as an allowable measure. WPN 00-5: Approval of Replacement Refrigerators and Electric Water

  4. High Efficiency R-744 Commercial Heat Pump Water Heaters

    SciTech Connect (OSTI)

    Elbel, Dr. Stefan W.; Petersen, Michael

    2013-04-25

    The project investigated the development and improvement process of a R744 (CO2) commercial heat pump water heater (HPWH) package of approximately 35 kW. The improvement process covered all main components of the system. More specific the heat exchangers (Internal heat exchanger, Evaporator, Gas cooler) as well as the expansion device and the compressor were investigated. In addition, a comparison to a commercially available baseline R134a unit of the same capacity and footprint was made in order to compare performance as well as package size reduction potential.

  5. Heat Pump Water Heater using Solid-State Energy Converters | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Water Heater using Solid-State Energy Converters Heat Pump Water Heater using Solid-State Energy Converters Sheetak will work on developing a full scale prototype of its low cost heat pump water heater. These solid state heat pumping elements can be implemented in low cost manner which have the potential to dramatically change the way in which he heat water.<BR />Image: Sheetak Sheetak will work on developing a full scale prototype of its low cost heat pump water heater. These

  6. Energy Factor Analysis for Gas Heat Pump Water Heaters

    SciTech Connect (OSTI)

    Gluesenkamp, Kyle R

    2016-01-01

    Gas heat pump water heaters (HPWHs) can improve water heating efficiency with zero GWP and zero ODP working fluids. The energy factor (EF) of a gas HPWH is sensitive to several factors. In this work, expressions are derived for EF of gas HPWHs, as a function of heat pump cycle COP, tank heat losses, burner efficiency, electrical draw, and effectiveness of supplemental heat exchangers. The expressions are used to investigate the sensitivity of EF to each parameter. EF is evaluated on a site energy basis (as used by the US DOE for rating water heater EF), and a primary energy-basis energy factor (PEF) is also defined and included. Typical ranges of values for the six parameters are given. For gas HPWHs, using typical ranges for component performance, EF will be 59 80% of the heat pump cycle thermal COP (for example, a COP of 1.60 may result in an EF of 0.94 1.28). Most of the reduction in COP is due to burner efficiency and tank heat losses. Gas-fired HPWHs are theoretically be capable of an EF of up to 1.7 (PEF of 1.6); while an EF of 1.1 1.3 (PEF of 1.0 1.1) is expected from an early market entry.

  7. Assessing the Energy Savings of Tankless Water Heater Retrofits in Public Housing

    SciTech Connect (OSTI)

    Ries, R.; Walters, R.; Dwiantoro, D.

    2013-01-01

    This report describes the methodology, analysis, and findings from a case study of a 110 unit retrofit of gas tankless water heaters in a hot/humid climate in Alachua County, Florida. The housing units had their gas-fired tank type water heaters replaced with gas-fired tankless water heaters as part of a federal program that targeted reduced energy use in public housing.

  8. Assessing the Energy Savings of Tankless Water Heater Retrofits in Public Housing

    SciTech Connect (OSTI)

    Ries, R.; Walters, R.; Dwiantoro, D.

    2013-01-01

    This report describes the methodology, analysis, and findings from a case study of a 110 unit retrofit of gas tankless water heaters in a hot/humid climate in Alachua County, Florida.The gas-fired tank type water heaters in the housing units were replaced with gas-fired tankless water heaters as part of a federal program that targeted reduced energy use in public housing.

  9. An Evaluation of the Water Heater Load Potential for Providing Regulation Service

    SciTech Connect (OSTI)

    Kondoh, Junji; Lu, Ning; Hammerstrom, Donald J.

    2011-08-31

    This paper investigates the possibility of providing aggregated regulation services with small loads, such as water heaters or air conditioners. A direct-load control algorithm is presented to aggregate the water heater load for the purpose of regulation. A dual-element electric water heater model is developed, which accounts for both thermal dynamics and users’ water consumptions. A realistic regulation signal was used to evaluate the number of water heaters needed and the operational characteristics of a water heater when providing 2-MW regulation service. Modeling results suggest that approximately 33,333 water heaters are needed to provide a 2-MW regulation service 24 hours a day. However, if water heaters only provide regulation from 6:00 to 24:00, approximately 20,000 will be needed. Because the control algorithm has considered the thermal setting of the water heater, the customer comfort is obstructed little. Therefore, the aggregated regulation service provided by water heater loads can become a major source of revenue for load-service entities when the smart grid enables the direct load control.

  10. Mountain Association for Community Economic Development- Solar Water Heater Loan Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Kentucky Solar Partnership (KSP) and the Mountain Association for Community Economic Development (MACED) partner to offer low interest loans for the installation of solar water heaters. Loans...

  11. Ex Parte Memorandum on Grid-Enabled Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    on Grid-Enabled Water Heaters Ex Parte Memorandum on Grid-Enabled Water Heaters On September 26, 2013 a number of stakeholders met with DOE representatives regarding water heater standards and thermal storage and demand response programs. DOE exparte memo_10_02_13 (99.23 KB) Grid-Enabled_Water_Heater_Amendment (27.15 KB) More Documents & Publications EPAct 2005. Conference Report, July 27, 2005 E:\BILLS\H6.PP In the Senate of the United States,June 28, 2005.

  12. DOE_EnergyEfficiencyStandardsForLargeVolumeWaterHeaters.pdf

    Broader source: Energy.gov (indexed) [DOE]

    and information on the use of electric thermal storage water heaters in utility demand response programs, and on the impact that the energy efficiency standards established by ...

  13. Estimating Costs and Efficiency of Storage, Demand, and Heat Pump Water Heaters

    Broader source: Energy.gov [DOE]

    Calculating the efficiency and operating cost of your water heater can help you decide which model is right for your household.

  14. Technical Highlight: NREL Tests Integrated Heat Pump Water Heater Performance in Different Climates

    SciTech Connect (OSTI)

    Sparn, Bethany

    2012-01-01

    This technical highlight describes NREL tests to capture information about heat pump performance across a wide range of ambient conditions for five heat pump water heaters.

  15. HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This presentation at the 2014 Peer Review provided an overview of the Building Technologies Office's HVAC, Water Heater and Appliance R&D activities. Through robust feedback, the BTO Program Peer Review enhances existing efforts and improves future designs. View the Presentation HVAC, Water Heater and Appliance R&D

  16. A Realistic Hot Water Draw Specification for Rating Solar Water Heaters

    SciTech Connect (OSTI)

    Burch, J.

    2012-06-01

    In the United States, annual performance ratings for solar water heaters are simulated, using TMY weather and specified water draw. This paper proposes a more realistic ratings draw that eliminates most bias by improving mains inlet temperature and by specifying realistic hot water use. Presented at the 2012 World Renewable Energy Forum; Denver, Colorado; May 13-17, 2012.

  17. Heat pump water heater and storage tank assembly

    DOE Patents [OSTI]

    Dieckmann, John T.; Nowicki, Brian J.; Teagan, W. Peter; Zogg, Robert

    1999-09-07

    A water heater and storage tank assembly comprises a housing defining a chamber, an inlet for admitting cold water to the chamber, and an outlet for permitting flow of hot water from the chamber. A compressor is mounted on the housing and is removed from the chamber. A condenser comprises a tube adapted to receive refrigerant from the compressor, and winding around the chamber to impart heat to water in the chamber. An evaporator is mounted on the housing and removed from the chamber, the evaporator being adapted to receive refrigerant from the condenser and to discharge refrigerant to conduits in communication with the compressor. An electric resistance element extends into the chamber, and a thermostat is disposed in the chamber and is operative to sense water temperature and to actuate the resistance element upon the water temperature dropping to a selected level. The assembly includes a first connection at an external end of the inlet, a second connection at an external end of the outlet, and a third connection for connecting the resistance element, compressor and evaporator to an electrical power source.

  18. Analysis of Large- Capacity Water Heaters in Electric Thermal Storage Programs

    SciTech Connect (OSTI)

    Cooke, Alan L.; Anderson, David M.; Winiarski, David W.; Carmichael, Robert T.; Mayhorn, Ebony T.; Fisher, Andrew R.

    2015-03-17

    This report documents a national impact analysis of large tank heat pump water heaters (HPWH) in electric thermal storage (ETS) programs and conveys the findings related to concerns raised by utilities regarding the ability of large-tank heat pump water heaters to provide electric thermal storage services.

  19. Buildings Energy Data Book: 5.4 Water Heaters

    Buildings Energy Data Book [EERE]

    5 Water Heater Efficiencies 2005 2010 Efficiency Stock Minimum Best-Available Residential Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage EF 0.90 0.90 (2) 0.95 (2) Electric Instantaneous EF 0.82 0.82 0.98 Electric Heat Pump EF 2.00 2.00 2.35 Gas-Fired Storage EF 0.60 0.59 (3) 0.85 (3) Gas-Fired Instantaneous EF 0.82 0.82 0.98 Oil-Fired Storage EF 0.50 0.53 (4) 0.68 (4) Solar SEF 2.50 N.A. 2.50 2007 2010 Efficiency Stock Minimum Best-Available Commercial Type

  20. Heat pump water heater and method of making the same

    DOE Patents [OSTI]

    Mei, Viung C.; Tomlinson, John J.; Chen, Fang C.

    2001-01-01

    An improved heat pump water heater wherein the condenser assembly of the heat pump is inserted into the water tank through an existing opening in the top of the tank, the assembly comprising a tube-in-a-tube construction with an elongated cylindrical outer body heat exchanger having a closed bottom with the superheated refrigerant that exits the compressor of the heat pump entering the top of the outer body. As the refrigerant condenses along the interior surface of the outer body, the heat from the refrigerant is transferred to the water through the outer body. The refrigerant then enters the bottom of an inner body coaxially disposed within the outer body and exits the top of the inner body into the refrigerant conduit leading into the expansion device of the heat pump. The outer body, in a second embodiment of the invention, acts not only as a heat exchanger but also as the sacrificial anode in the water tank by being constructed of a metal which is more likely to corrode than the metal of the tank.

  1. Development and Validation of a Gas-Fired Residential Heat Pump Water Heater - Final Report

    SciTech Connect (OSTI)

    Michael Garrabrant; Roger Stout; Paul Glanville; Janice Fitzgerald; Chris Keinath

    2013-01-21

    For gas-fired residential water heating, the U.S. and Canada is predominantly supplied by minimum efficiency storage water heaters with Energy Factors (EF) in the range of 0.59 to 0.62. Higher efficiency and higher cost ($700 - $2,000) options serve about 15% of the market, but still have EFs below 1.0, ranging from 0.65 to 0.95. To develop a new class of water heating products that exceeds the traditional limit of thermal efficiency, the project team designed and demonstrated a packaged water heater driven by a gas-fired ammonia-water absorption heat pump. This gas-fired heat pump water heater can achieve EFs of 1.3 or higher, at a consumer cost of $2,000 or less. Led by Stone Mountain Technologies Inc. (SMTI), with support from A.O. Smith, the Gas Technology Institute (GTI), and Georgia Tech, the cross-functional team completed research and development tasks including cycle modeling, breadboard evaluation of two cycles and two heat exchanger classes, heat pump/storage tank integration, compact solution pump development, combustion system specification, and evaluation of packaged prototype GHPWHs. The heat pump system extracts low grade heat from the ambient air and produces high grade heat suitable for heating water in a storage tank for domestic use. Product features that include conventional installation practices, standard footprint and reasonable economic payback, position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions from domestic hot water production.

  2. Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

    SciTech Connect (OSTI)

    Kingston, T.; Scott, S.

    2013-03-01

    Homebuilders are exploring more cost effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads with the following key findings: 1) The tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system. 2) The tankless combo system consistently achieved better daily efficiencies (i.e. 84%-93%) than the storage combo system (i.e. 81%- 91%) when the air handler was sized adequately and adjusted properly to achieve significant condensing operation. When condensing operation was not achieved, both systems performed with lower (i.e. 75%-88%), but similar efficiencies. 3) Air handlers currently packaged with combo systems are not designed to optimize condensing operation. More research is needed to develop air handlers specifically designed for condensing water heaters. 4) System efficiencies greater than 90% were achieved only on days where continual and steady space heating loads were required with significant condensing operation. For days where heating was more intermittent, the system efficiencies fell below 90%.

  3. Exparte Memo: 4-26-16 Meeting on Test Procedures for Water Heaters,

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    EERE-2015-BT-TP-0007-0002 | Department of Energy Exparte Memo: 4-26-16 Meeting on Test Procedures for Water Heaters, EERE-2015-BT-TP-0007-0002 Exparte Memo: 4-26-16 Meeting on Test Procedures for Water Heaters, EERE-2015-BT-TP-0007-0002 Energy Conservation Program for Consumer Products and Certain Industrial Equipment: Test Procedures for Water Heaters, EERE-2015-BT-TP-0007-0002, specifically issues surrounding the Conversion Factor status. EXPARTE MEMO 4 26-rbc (83.88 KB) More Documents

  4. Realistic Hot Water Draw Specification for Rating Solar Water Heaters: Preprint

    SciTech Connect (OSTI)

    Burch, J.

    2012-06-01

    In the United States, annual performance ratings for solar water heaters are simulated, using TMY weather and specified water draw. A more-realistic ratings draw is proposed that eliminates most bias by improving mains inlet temperature and by specifying realistic hot water use. This paper outlines the current and the proposed draws and estimates typical ratings changes from draw specification changes for typical systems in four cities.

  5. Effect of Fuel Wobbe Number on Pollutant Emissions from Advanced Technology Residential Water Heaters: Results of Controlled Experiments

    SciTech Connect (OSTI)

    Rapp, Vi H.; Singer, Brett C.

    2014-03-01

    The research summarized in this report is part of a larger effort to evaluate the potential air quality impacts of using liquefied natural gas in California. A difference of potential importance between many liquefied natural gas blends and the natural gas blends that have been distributed in California in recent years is the higher Wobbe number of liquefied natural gas. Wobbe number is a measure of the energy delivery rate for appliances that use orifice- or pressure-based fuel metering. The effect of Wobbe number on pollutant emissions from residential water heaters was evaluated in controlled experiments. Experiments were conducted on eight storage water heaters, including five with “ultra low-NO{sub X}” burners, and four on-demand (tankless) water heaters, all of which featured ultra low-NO{sub X} burners. Pollutant emissions were quantified as air-free concentrations in the appliance flue and fuel-based emission factors in units of nanogram of pollutant emitter per joule of fuel energy consumed. Emissions were measured for carbon monoxide (CO), nitrogen oxides (NO{sub X}), nitrogen oxide (NO), formaldehyde and acetaldehyde as the water heaters were operated through defined operating cycles using fuels with varying Wobbe number. The reference fuel was Northern California line gas with Wobbe number ranging from 1344 to 1365. Test fuels had Wobbe numbers of 1360, 1390 and 1420. The most prominent finding was an increase in NO{sub X} emissions with increasing Wobbe number: all five of the ultra low-NO{sub X} storage water heaters and two of the four ultra low-NO{sub X} on-demand water heaters had statistically discernible (p<0.10) increases in NO{sub X} with fuel Wobbe number. The largest percentage increases occurred for the ultra low-NO{sub X} water heaters. There was a discernible change in CO emissions with Wobbe number for all four of the on-demand devices tested. The on-demand water heater with the highest CO emissions also had the largest CO increase

  6. Clay Electric Cooperative, Inc- Energy Smart Solar Water Heater Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Clay Electric Cooperative (CEC) provides a rebate of $0.01 per BTU output to its residential members when they purchase qualified solar water heaters. This rebate is capped at 60,000 BTUs per...

  7. Tri-County Electric Cooperative- Energy Efficient Water Heater Rebate Program

    Broader source: Energy.gov [DOE]

    Tri-County Electric Cooperative offers a $75 rebate on the purchase of energy-efficient electric water heaters. The rebate is valid for new or replacement units which have an Energy Factor Rating...

  8. Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems

    SciTech Connect (OSTI)

    Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

    2012-07-01

    The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

  9. Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

    SciTech Connect (OSTI)

    Maguire, Jeff; Burch, Jay; Merrigan, Tim; Ong, Sean

    2013-07-01

    Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  10. Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

    SciTech Connect (OSTI)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2013-07-01

    Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

  11. Max Tech Electric Heat Pump Water Heater with Lower GWP Halogenated

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Refrigerant | Department of Energy Max Tech Electric Heat Pump Water Heater with Lower GWP Halogenated Refrigerant Max Tech Electric Heat Pump Water Heater with Lower GWP Halogenated Refrigerant Information flow schematic for an integrated heat pump design model and wrapped tank model. Image credit: Oak Ridge National Laboratory. Information flow schematic for an integrated heat pump design model and wrapped tank model. Image credit: Oak Ridge National Laboratory. Information flow schematic

  12. Commercial CO2 Electric Heat Pump Water Heater | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    CO2 Electric Heat Pump Water Heater Commercial CO2 Electric Heat Pump Water Heater Planned enhanced modeling approach to facilitate analyses of wrapped-tank options for the project. Image credit: Oak Ridge National Laboratory. Planned enhanced modeling approach to facilitate analyses of wrapped-tank options for the project. Image credit: Oak Ridge National Laboratory. Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN FY16 DOE Funding: $150,000 Project Term: October 1, 2015 - TBD

  13. Method and apparatus for enhanced heat recovery from steam generators and water heaters

    DOE Patents [OSTI]

    Knight, Richard A.; Rabovitser, Iosif K.; Wang, Dexin

    2006-06-27

    A heating system having a steam generator or water heater, at least one economizer, at least one condenser and at least one oxidant heater arranged in a manner so as to reduce the temperature and humidity of the exhaust gas (flue gas) stream and recover a major portion of the associated sensible and latent heat. The recovered heat is returned to the steam generator or water heater so as to increase the quantity of steam generated or water heated per quantity of fuel consumed. In addition, a portion of the water vapor produced by combustion of fuel is reclaimed for use as feed water, thereby reducing the make-up water requirement for the system.

  14. Development of an Accurate Feed-Forward Temperature Control Tankless Water Heater

    SciTech Connect (OSTI)

    David Yuill

    2008-06-30

    The following document is the final report for DE-FC26-05NT42327: Development of an Accurate Feed-Forward Temperature Control Tankless Water Heater. This work was carried out under a cooperative agreement from the Department of Energy's National Energy Technology Laboratory, with additional funding from Keltech, Inc. The objective of the project was to improve the temperature control performance of an electric tankless water heater (TWH). The reason for doing this is to minimize or eliminate one of the barriers to wider adoption of the TWH. TWH use less energy than typical (storage) water heaters because of the elimination of standby losses, so wider adoption will lead to reduced energy consumption. The project was carried out by Building Solutions, Inc. (BSI), a small business based in Omaha, Nebraska. BSI partnered with Keltech, Inc., a manufacturer of electric tankless water heaters based in Delton, Michigan. Additional work was carried out by the University of Nebraska and Mike Coward. A background study revealed several advantages and disadvantages to TWH. Besides using less energy than storage heaters, TWH provide an endless supply of hot water, have a longer life, use less floor space, can be used at point-of-use, and are suitable as boosters to enable alternative water heating technologies, such as solar or heat-pump water heaters. Their disadvantages are their higher cost, large instantaneous power requirement, and poor temperature control. A test method was developed to quantify performance under a representative range of disturbances to flow rate and inlet temperature. A device capable of conducting this test was designed and built. Some heaters currently on the market were tested, and were found to perform quite poorly. A new controller was designed using model predictive control (MPC). This control method required an accurate dynamic model to be created and required significant tuning to the controller before good control was achieved. The MPC design

  15. NREL Tests Integrated Heat Pump Water Heater Performance in Different Climates (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-01-01

    This technical highlight describes NREL tests to capture information about heat pump performance across a wide range of ambient conditions for five heat pump water heaters (HPWH). These water heaters have the potential to significantly reduce water heater energy use relative to traditional electric resistance water heaters. These tests have provided detailed performance data for these appliances, which have been used to evaluate the cost of saved energy as a function of climate. The performance of HPWHs is dependent on ambient air temperature and humidity and the logic controlling the heat pump and the backup resistance heaters. The laboratory tests were designed to measure each unit's performance across a range of air conditions and determine the specific logic controlling the two heat sources, which has a large effect on the comfort of the users and the energy efficiency of the system. Unlike other types of water heaters, HPWHs are both influenced by and have an effect on their surroundings. Since these effects are complex and different for virtually every house and climate region, creating an accurate HPWH model from the data gathered during the laboratory tests was a main goal of the project. Using the results from NREL's laboratory tests, such as the Coefficient of Performance (COP) curves for different air conditions as shown in Figure 1, an existing HPWH model is being modified to produce more accurate whole-house simulations. This will allow the interactions between the HPWH and the home's heating and cooling system to be evaluated in detail, for any climate region. Once these modeling capabilities are in place, a realistic cost-benefit analysis can be performed for a HPWH installation anywhere in the country. An accurate HPWH model will help to quantify the savings associated with installing a HPWH in the place of a standard electric water heater. In most locations, HPWHs are not yet a cost-effective alternative to natural gas water heaters. The detailed

  16. The Newest Addition to the ENERGY STAR Lineup: Water Heaters | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy The Newest Addition to the ENERGY STAR Lineup: Water Heaters The Newest Addition to the ENERGY STAR Lineup: Water Heaters February 17, 2009 - 9:48am Addthis Elizabeth Spencer Communicator, National Renewable Energy Laboratory If you've gone shopping for new appliances sometime in the last decade, then you're probably familiar with the ENERGY STAR® label. ENERGY STAR is a partnership between the U.S. Department of Energy and the U.S. Environmental Protection Agency that sets

  17. An International Survey of Electric Storage Tank Water Heater Efficiency and Standards

    SciTech Connect (OSTI)

    Johnson, Alissa; Lutz, James; McNeil, Michael A.; Covary, Theo

    2013-11-13

    Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

  18. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.: Preprint

    SciTech Connect (OSTI)

    Maguire, J.; Burch, J.; Merrigan, T.; Ong, S.

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently reemerged on the U.S. market. These units have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine what actual in use energy consumption of a HPWH may be in different regions of the U.S., annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the U.S. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  19. Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.

    SciTech Connect (OSTI)

    Maguire, Jeff; Burch, Jay; Merrigan, Tim; Ong, Sean

    2014-01-01

    Residential heat pump water heaters (HPWHs) have recently re-emerged on the U.S. market, and they have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine the actual energy consumption of a HPWH in different U.S. regions, annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the United States. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

  20. Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating

    SciTech Connect (OSTI)

    Kingston, T.; Scott, S.

    2013-03-01

    Homebuilders are exploring more cost-effective combined space and water heating systems (combo systems) with major water heater manufacturers that are offering pre-engineered forced air space heating combo systems. In this project, unlike standardized tests, laboratory tests were conducted that subjected condensing tankless and storage water heater based combo systems to realistic, coincidental space and domestic hot water loads and found that the tankless combo system maintained more stable DHW and space heating temperatures than the storage combo system, among other key findings.

  1. Covered Product Category: Residential Whole-Home Gas Tankless Water Heaters

    Office of Energy Efficiency and Renewable Energy (EERE)

    FEMP provides acquisition guidance across a variety of product categories, including whole-home gas tankless water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  2. Covered Product Category: Residential Whole-Home Gas Tankless Water Heaters

    Broader source: Energy.gov [DOE]

    FEMP provides acquisition guidance across a variety of product categories, including whole-home gas tankless water heaters, which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

  3. Development of High Efficiency Carbon Dioxide Commercial Heat Pump Water Heater

    SciTech Connect (OSTI)

    Michael PETERSEN; Chad D. BOWERS; Stefan ELBEL; Pega HRNJAK

    2012-07-01

    Although heat pump water heaters are today widely accepted in both Japan and Europe, where energy costs are high and government incentives for their use exist, acceptance of such products in the US has been limited. While this trend is slowly changing with the introduction of heat pump water heaters into the residential market, but acceptance remains low in the commercial sector. The objective of the presented work is the development of a high efficiency R744 heat pump water heater for commercial applications with effective utilization of the cooling capability for air conditioning and/or refrigeration. The ultimate goal is to achieve total system COP of up to 8. This unit will be targeted at commercial use where some cooling load is typically needed year round, such as restaurants, hotels, nursing homes, and hospitals. This paper presents the performance results from the development of four R744 commercial heat pump water heater packages of approximately 35 kW and comparison to a commercially available baseline R134a unit of the same capacity and footprint. In addition, the influences of an internal heat exchanger and an enhanced evaporator on the system performance are described and recommendations are made for further improvements of the R744 system.

  4. Measure Guideline. Heat Pump Water Heaters in New and Existing Homes

    SciTech Connect (OSTI)

    Shapiro, Carl; Puttagunta, Srikanth; Owens, Douglas

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs

  5. Aqueous propylene-glycol concentrations for the freeze protection of thermosyphon solar energy water heaters

    SciTech Connect (OSTI)

    Norton, B. ); Edmonds, J.E.J. )

    1991-01-01

    Using a validated dynamic simulation model, the thermal performance of an indirect thermosyphon solar energy water heater was examined. The heat transfer fluids employed were aqueous solutions of propylene glycol. The effect of varying the glycol concentration on the hot water output and efficacy of freeze protection was determined for a specific pattern of hot water withdrawal and weather for the temperature maritime climate of London, England. The heat output is compared with that of a drain-down direct system.

  6. ISSUANCE 2015-05-12: Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment: Test Procedures for Consumer and Commercial Water Heaters

    Broader source: Energy.gov [DOE]

    Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment: Test Procedures for Consumer and Commercial Water Heaters

  7. West Village Community: Quality Management Processes and Preliminary Heat Pump Water Heater Performance

    SciTech Connect (OSTI)

    Dakin, B.; Backman, C.; Hoeschele, M.; German, A.

    2012-11-01

    West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. The project when complete will provide housing for students, faculty, and staff with a vision to minimize the community's impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

  8. West Village Community. Quality Management Processes and Preliminary Heat Pump Water Heater Performance

    SciTech Connect (OSTI)

    Dakin, B.; Backman, C.; Hoeschele, M.; German, A.

    2012-11-01

    West Village, a multi-use project underway at the University of California Davis, represents a ground-breaking sustainable community incorporating energy efficiency measures and on-site renewable generation to achieve community-level Zero Net Energy (ZNE) goals. When complete, the project will provide housing for students, faculty, and staff with a vision to minimize the community’s impact on energy use by reducing building energy use, providing on-site generation, and encouraging alternative forms of transportation. This focus of this research is on the 192 student apartments that were completed in 2011 under Phase I of the West Village multi-year project. The numerous aggressive energy efficiency measures implemented result in estimated source energy savings of 37% over the B10 Benchmark. There are two primary objectives of this research. The first is to evaluate performance and efficiency of the central heat pump water heaters as a strategy to provide efficient electric water heating for net-zero all-electric buildings and where natural gas is not available on site. In addition, effectiveness of the quality assurance and quality control processes implemented to ensure proper system commissioning and to meet program participation requirements is evaluated. Recommendations for improvements that could improve successful implementation for large-scale, high performance communities are identified.

  9. Field Performance of Heat Pump Water Heaters in the Northeast, Massachusetts and Rhode Island (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-12-01

    Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring, A.O. Smith Voltex, and Stiebel Eltron Accelera 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

  10. Building America Top Innovations 2012: Tankless Gas Water Heater Performance

    SciTech Connect (OSTI)

    none,

    2013-01-01

    This Building America Top Innovations profile describes Building America field testing that shed light on how real-world water usage affects energy saving estimates of high-efficiency water heating systems.

  11. Measure Guideline: Heat Pump Water Heaters in New and Existing Homes

    SciTech Connect (OSTI)

    Shapiro, C.; Puttagunta, S.; Owens, D.

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Heat pump water heaters (HPWHs) promise to significantly reduce energy consumption for domestic hot water (DHW) over standard electric resistance water heaters (ERWHs). While ERWHs perform with energy factors (EFs) around 0.9, new HPWHs boast EFs upwards of 2.0. High energy factors in HPWHs are achieved by combining a vapor compression system, which extracts heat from the surrounding air at high efficiencies, with electric resistance element(s), which are better suited to meet large hot water demands. Swapping ERWHs with HPWHs could result in roughly 50% reduction in water heating energy consumption for 35.6% of all U.S. households. This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. While HPWHs promise to significantly reduce energy use for DHW, proper installation, selection, and maintenance of HPWHs is required to ensure high operating efficiency and reliability. This document is intended to explore the issues surrounding HPWHs to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Section 1 of this guideline provides a brief description of HPWHs and their operation. Section 2 highlights the cost and energy savings of HPWHs as well as the variables that affect HPWH performance, reliability, and efficiency. Section 3 gives guidelines for proper installation and maintenance of HPWHs, selection criteria for locating HPWHs, and highlights of important differences between ERWH and HPWH installations. Throughout this document, CARB has included results from the evaluation of 14 heat pump water heaters (including three recently released HPWH

  12. CO2 Heat Pump Water Heater | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    other refrigerants), CO2 also has greater potential for use in residentialcommercial demand response units, as well as for high-temperature commercial water heating applications. ...

  13. The elimination of the reverse circulation in thermosiphon solar water heaters

    SciTech Connect (OSTI)

    Prapas, D.E.; Sotiropoulos, B.A. )

    1991-01-01

    Thermosiphon solar water heaters (TSWH), employing either closed or open collector loops, are widely used today to cover a substantial part of the hot water needs, mostly in residential small scale applications. Their cost is lower in comparison to pumped systems, because no pumps, controls etc. are required. However, the storage tank has to be mounted above the collector in order to promote the thermosiphon flow; this could be a serious drawback in some applications. An undesirable characteristic of TSWH is the reverse circulation (RC) of the working liquid when the temperature of the collector is lower than that of the storage tank. The causes of reverse circulation in thermosyphon solar water heaters, the geometry of the systems, and the affects of nocturnal radiative cooling of the collector are discussed. A means of interconnecting collector and tank to drastically reduce reverse circulation is presented.

  14. Impact on Water Heater Performance of Heating Methods that Promote Tank Temperature Stratification

    SciTech Connect (OSTI)

    Gluesenkamp, Kyle R; BushPE, John D

    2016-01-01

    During heating of a water heater tank, the vertical temperature stratification of the water can be increased or decreased, depending on the method of heating. Methods that increase stratification during heating include (1) removing cold water from the tank bottom, heating it, and re-introducing it to the tank top at relatively low flow rate, (2) using a heat exchanger wrapped around the tank, through which heating fluid (with finite specific heat) flows from top to bottom, and (3) using an immersed heat element that is relatively high in the tank. Using such methods allows for improved heat pump water heater (HPWH) cycle efficiencies when the heat pump can take advantage of the lower temperatures that exist lower in the tank, and accommodate the resulting glide. Transcritical cycles are especially well-suited to capitalize on this opportunity, and other HPWH configurations (that have been proposed elsewhere) may benefit as well. This work provides several stratification categories of heat pump water heater tank configurations relevant to their stratification potential. To illustrate key differences among categories, it also compiles available experimental data for (a) single pass pumped flow, (b) multi-pass pumped flow, and (c) top-down wrapped tank with transcritical refrigerant.

  15. EERE Success Story—Xergy Develops Breakthrough Water Heater Compressor

    Office of Energy Efficiency and Renewable Energy (EERE)

    New HVAC, water heating, and appliance technologies that work without conventional refrigerants are critical for the U.S. Department of Energy (DOE) to reach its long-term goal of cutting building...

  16. Xergy Ships First Breakthrough Water Heater Compressor to GE

    Office of Energy Efficiency and Renewable Energy (EERE)

    New HVAC, water heating, and appliance technologies that work without conventional refrigerants are critical for the U.S. Department of Energy (DOE) to reach its long-term goal of cutting building...

  17. Orlando Utilities Commission- Residential Solar Water Heater Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Through a partnership with the Orlando Federal Credit Union (OFCU), OUC also offers a Residential Solar Loan Program to finance the solar hot water system. Customers who choose to finance through...

  18. Outdoor Outfitter Gets Greener With Solar Water Heater

    Broader source: Energy.gov [DOE]

    Using Recovery Act funding, L.L. Bean, the popular outdoor apparel company, recently installed a 180-tube solar hot water collector array on the roof of their flagship store in Freeport, Maine. Find out some how much energy and money they're saving thanks to the new solar installation.

  19. Refrigerant charge management in a heat pump water heater

    SciTech Connect (OSTI)

    Chen, Jie; Hampton, Justin W.

    2014-06-24

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

  20. Study Design And Realization Of Solar Water Heater

    SciTech Connect (OSTI)

    Lounis, M.; Boudjemaa, F.; Akil, S. Kouider

    2011-01-17

    Solar is one of the most easily exploitable energy, it is moreover inexhaustible. His applications are many and are varied. The heating of the domestic water is one of the most immediate, simplest and also of most widespread exploitation of the solar energy. Algeria, from its geographical situation, it deposits one of the largest high sun surface expositions in the world. The exposition duration of the almost territory exceeds 2000 hours annually and can reach the 3900 hours (high plateaus and Sahara). By knowing the daily energy received by 1 m{sup 2} of a horizontal surface of the solar thermal panel is nearly around 1700 KWh/m{sup 2} a year in the north and 2263 KWh/m{sup 2} a year in the south of the country, we release the most important and strategic place of the solar technologies in the present and in the future for Algeria. This work consists to study, conceive and manufacture solar water heating with the available local materials so, this type of the energy will be profitable for all, particularly the poor countries. If we consider the illumination duration of the panel around 6 hours a day, the water heat panel manufactured in our laboratory produce an equivalent energy of 11.615 KWh a day so, 4239 KWh a year. These values of energy can be easily increased with performing the panel manufacture.

  1. ENERGY STAR Residential Water Heaters to Save Americans Up to $823 Million in the Next Five Years

    Broader source: Energy.gov [DOE]

    WASHINGTON - The U.S. Department of Energy (DOE) today announced the availability of ENERGY STAR® residential water heaters. With today's announcement, the ENERGY STAR® program now addresses every...

  2. Energy Saving Absorption Heat Pump Water Heater - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Security Administration | (NNSA) Energy Saving "Cool Roofs" Installed at Y-12 October 17, 2012 The Y-12 National Security Complex has taken additional steps to reduce its energy costs by installing almost 100,000 square feet of new heat reflective "cool" roofs at the Oak Ridge, Tennessee facility. File 2012-10-17 NPO Y-12 Cool Roofs.docx

    Building Energy Efficiency Building Energy Efficiency Find More Like This Return to Search Energy Saving Absorption Heat Pump Water

  3. Heat Pump Water Heater Technology: Experiences of Residential Consumers and Utilities

    SciTech Connect (OSTI)

    Ashdown, BG

    2004-08-04

    This paper presents a case study of the residential heat pump water heater (HPWH) market. Its principal purpose is to evaluate the extent to which the HPWH will penetrate the residential market sector, given current market trends, producer and consumer attributes, and technical parameters. The report's secondary purpose is to gather background information leading to a generic framework for conducting market analyses of technologies. This framework can be used to compare readiness and to factor attributes of market demand back into product design. This study is a rapid prototype analysis rather than a detailed case analysis. For this reason, primary data collection was limited and reliance on secondary sources was extensive. Despite having met its technical goals and having been on the market for twenty years, the HPWH has had virtually no impact on contributing to the nation's water heating. In some cases, HPWH reliability and quality control are well below market expectations, and early units developed a reputation for unreliability, especially when measured against conventional water heaters. In addition to reliability problems, first costs of HPWH units can be three to five times higher than conventional units. Without a solid, well-managed business plan, most consumers will not be drawn to this product. This is unfortunate. Despite its higher first costs, efficiency of an HPWH is double that of a conventional water heater. The HPWH also offers an attractive payback period of two to five years, depending on hot water usage. On a strict life-cycle basis it supplies hot water very cost effectively. Water heating accounts for 17% of the nation's residential consumption of electricity (see chart at left)--water heating is second only to space heating in total residential energy use. Simple arithmetic suggests that this figure could be reduced to the extent HPWH technology displaces conventional water heating. In addition, the HPWH offers other benefits. Because it

  4. Solar conductive spa water heater and safety cover

    SciTech Connect (OSTI)

    Ely, G.W.

    1987-04-28

    This patent describes a solar conductive portable cover for a spa which has an opening for access comprising a rigid plastic member vacuum formed in a series of interconnected parallel U-shaped channels. Each channel is separated from an adjacent channel by a wall. A shape conforms plastic top solvent or heat is welded to a top surface of the walls to form a cover wider in diameter than the opening of the spa, such that the cover rests on coping at the top of the spa. Method is described for heating water for a spa comprising covering the top of the spa with a portable rigid thin plastic member forming a cover wider than the opening of the spa such that the cover rests on coping at the top of the spa and having a series of parallel U-shaped channels.

  5. Refrigerant charge management in a heat pump water heater

    DOE Patents [OSTI]

    Chen, Jie; Hampton, Justin W.

    2016-07-05

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, and methods of managing refrigerant charge. Various embodiments remove idle refrigerant from a heat exchanger that is not needed for transferring heat by opening a refrigerant recovery valve and delivering the idle refrigerant from the heat exchanger to an inlet port on the compressor. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled by controlling how much refrigerant is drawn from the heat exchanger, by letting some refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and various components can be interconnected with refrigerant conduit. Some embodiments deliver refrigerant gas to the heat exchanger and drive liquid refrigerant out prior to isolating the heat exchanger.

  6. Building America Expert Meeting: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems

    Broader source: Energy.gov [DOE]

    The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

  7. Revisions to the SRCC Rating Process for Solar Water Heaters: Preprint

    SciTech Connect (OSTI)

    Burch, J.; Huggins, J.; Long, S.; Thornton, J.

    2012-06-01

    In the United States, annual performance ratings for solar water heaters are computed with component-based simulation models driven by typical meteorological year weather and specified water draw. Changes in the process are being implemented to enhance credibility through increased transparency and accuracy. Changes to the process include using a graphical rather than text-based model-building tool, performing analytical tests on all components and systems, checking energy balances on every component, loop, and system at every time step, comparing the results to detect outliers and potential errors, and documenting the modeling process in detail. Examples of changes in ratings are shown, along with analytical and comparative testing results.

  8. Impact of Pilot Light Modeling on the Predicted Annual Performance of Residential Gas Water Heaters: Preprint

    SciTech Connect (OSTI)

    Maguire, J.; Burch, J.

    2013-08-01

    Modeling residential water heaters with dynamic simulation models can provide accurate estimates of their annual energy consumption, if the units? characteristics and use conditions are known. Most gas storage water heaters (GSWHs) include a standing pilot light. It is generally assumed that the pilot light energy will help make up standby losses and have no impact on the predicted annual energy consumption. However, that is not always the case. The gas input rate and conversion efficiency of a pilot light for a GSWH were determined from laboratory data. The data were used in simulations of a typical GSWH with and without a pilot light, for two cases: 1) the GSWH is used alone; and 2) the GSWH is the second tank in a solar water heating (SWH) system. The sensitivity of wasted pilot light energy to annual hot water use, climate, and installation location was examined. The GSWH used alone in unconditioned space in a hot climate had a slight increase in energy consumption. The GSWH with a pilot light used as a backup to an SWH used up to 80% more auxiliary energy than one without in hot, sunny locations, from increased tank losses.

  9. Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort

    SciTech Connect (OSTI)

    Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

    2014-07-21

    Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes’ space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

  10. 2015-03-25 Issuance: Definitions Regarding Consumer Water Heaters Notice of Proposed Rulemaking

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of proposed rulemaking regarding definitions for consumer water heaters, as issued by the Acting Deputy Assistant Secretary for Energy Efficiency on March 25, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  11. 2015-03-26 Issuance: Residential Water Heaters; Notice of Proposed Rulemaking Withdrawal

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register notice of proposed rulemaking withdrawal regarding Energy Conservation Standards for Residential Water Heaters, as issued by the Acting Deputy Assistant Secretary for Energy Efficiency on March 26, 2015. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  12. 2014-06-27 Issuance: Test Procedures for Residential and Commercial Water Heaters; Final Rule

    Office of Energy Efficiency and Renewable Energy (EERE)

    This document is a pre-publication Federal Register final rule regarding test procedures for residential and commercial water heaters, as issued by the Deputy Assistant Secretary for Energy Efficiency on June 27, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  13. Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)

    SciTech Connect (OSTI)

    Metzger, C.; Puttagunta, S.; Williamson, J.

    2013-11-01

    Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

  14. Technology Solutions Case Study: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida

    SciTech Connect (OSTI)

    2013-11-01

    Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

  15. Modeling of Electric Water Heaters for Demand Response: A Baseline PDE Model

    SciTech Connect (OSTI)

    Xu, Zhijie; Diao, Ruisheng; Lu, Shuai; Lian, Jianming; Zhang, Yu

    2014-09-05

    Demand response (DR)control can effectively relieve balancing and frequency regulation burdens on conventional generators, facilitate integrating more renewable energy, and reduce generation and transmission investments needed to meet peak demands. Electric water heaters (EWHs) have a great potential in implementing DR control strategies because: (a) the EWH power consumption has a high correlation with daily load patterns; (b) they constitute a significant percentage of domestic electrical load; (c) the heating element is a resistor, without reactive power consumption; and (d) they can be used as energy storage devices when needed. Accurately modeling the dynamic behavior of EWHs is essential for designing DR controls. Various water heater models, simplified to different extents, were published in the literature; however, few of them were validated against field measurements, which may result in inaccuracy when implementing DR controls. In this paper, a partial differential equation physics-based model, developed to capture detailed temperature profiles at different tank locations, is validated against field test data for more than 10 days. The developed model shows very good performance in capturing water thermal dynamics for benchmark testing purposes

  16. ISSUANCE 2015-06-25: Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment: Test Procedures for Residential and Commercial Water Heaters; Correction

    Broader source: Energy.gov [DOE]

    Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment: Test Procedures for Residential and Commercial Water Heaters; Correction

  17. Assessing Consumer Values and the Supply-Chain Market for the Integrated Water Heater/Dehumidifier

    SciTech Connect (OSTI)

    Ashdown, BG

    2005-01-11

    This paper presents a case study of the potential market for the dual-service residential integrated water heater/dehumidifier (WHD). Its principal purpose is to evaluate the extent to which this integrated appliance might penetrate the residential market sector, given current market trends, producer and consumer attributes, and technical parameters. The report's secondary purpose is to gather background information leading to a generic framework for conducting market analyses of technologies. This framework can be used to assess market readiness as well as factor preferred product attributes into the design to drive consumer demand for this product. This study also supports analysis for prototype design. A full market analysis for potential commercialization should be conducted after prototype development. The integrated WHD is essentially a heat-pump water heater (HPWH) with components and controls that allow dedicated dehumidification. Adequate residential humidity control is a growing issue for newly constructed residential homes, which are insulated so well that mechanical ventilation may be necessary to meet fresh air requirements. Leveraging its successful experience with the energy-efficient design improvement for the residential HPWH, the Oak Ridge National Laboratory's (ORNL's) Engineering Science and Technology Division's (ESTD's) Building Equipment Group designed a water-heating appliance that combines HPWH efficiency with dedicated dehumidification. This integrated appliance could be a low-cost solution for dehumidification and efficient electric water heating. ORNL is partnering with Western Carolina University, Asheville-Buncombe Technical Community College, American Carolina Stamping Company, and Clemson University to develop this appliance and assess its market potential. For practical purposes, consumers are indifferent to how water is heated but are very interested in product attributes such as initial first cost, operating cost, performance

  18. Accuracy of the European solar water heater test procedure. Part 1: Measurement errors and parameter estimates

    SciTech Connect (OSTI)

    Rabl, A.; Leide, B. ); Carvalho, M.J.; Collares-Pereira, M. ); Bourges, B.

    1991-01-01

    The Collector and System Testing Group (CSTG) of the European Community has developed a procedure for testing the performance of solar water heaters. This procedure treats a solar water heater as a black box with input-output parameters that are determined by all-day tests. In the present study the authors carry out a systematic analysis of the accuracy of this procedure, in order to answer the question: what tolerances should one impose for the measurements and how many days of testing should one demand under what meteorological conditions, in order to be able to quarantee a specified maximum error for the long term performance The methodology is applicable to other test procedures as well. The present paper (Part 1) examines the measurement tolerances of the current version of the procedure and derives a priori estimates of the errors of the parameters; these errors are then compared with the regression results of the Round Robin test series. The companion paper (Part 2) evaluates the consequences for the accuracy of the long term performance prediction. The authors conclude that the CSTG test procedure makes it possible to predict the long term performance with standard errors around 5% for sunny climates (10% for cloudy climates). The apparent precision of individual test sequences is deceptive because of large systematic discrepancies between different sequences. Better results could be obtained by imposing tighter control on the constancy of the cold water supply temperature and on the environment of the test, the latter by enforcing the recommendation for the ventilation of the collector.

  19. National Solar Water Heater Workshop Present at DOE Region V meeting for managers of State Energy Extension Service and State Energy Conservation Plan, March 18-19, 1981

    SciTech Connect (OSTI)

    Mumma, S.A.; Marinello, M.G.

    1981-01-01

    After a brief description of the National Solar Water Heater Workshop and some comments by users of the solar water heater, the hardware supplier handbook is presented. The performance expected of a hardware supplier is described, solar system components and their specifications are listed, and information is provided to assist the hardware supplier in obtaining necessary materials. (LEW)

  20. Characteristics and experiences of applicants for HUD grants for solar water heaters

    SciTech Connect (OSTI)

    Jones, W.H.

    1980-01-01

    Thirty-eight winners and 45 losers of HUD solar water heater grants in the Florida panhandle were interviewed in 1978 concerning their experiences, and their solar installations were inspected. Operational problems were mostly attributable to control system failure. Grantees were generally pleased with the subsidy program. Grant recipients were not typical of the general public, in that they were mostly middle-aged, well-educated, reasonably affluent people who had a technical background, liked to do things on their own, and were fairly sophisticated so far as energy problems were concerned. It may be that the grant program is not having a great effect on solar energy commercialization, except perhaps in terms of publicity; the recipients generally would have installed systems without a grant, and most of the losers had gone ahead with a solar installation or were planning to do so.

  1. Research and Design of a Sample Heater for Beam Line 6-2c Transmission X-ray Microscope

    SciTech Connect (OSTI)

    Policht, Veronica; /Loyola U., Chicago /SLAC

    2012-08-27

    There exists a need for environmental control of samples to be imaged by the Transmission X-Ray Microscope (TXM) at the SSRLs Beam Line 6-2c. In order to observe heat-driven chemical or morphological changes that normally occur in situ, microscopes require an additional component that effectively heats a given sample without heating any of the microscope elements. The confinement of the heat and other concerns about the heaters integrity limit which type of heater is appropriate for the TXM. The bulk of this research project entails researching different heating methods used previously in microscopes, but also in other industrial applications, with the goal of determining the best-fitting method, and finally in designing a preliminary sample heater.

  2. Commercialization of air conditioning heat pump/water heater. Final technical report, Volume 1: Transmittal documents; Executive summary; Project summary

    SciTech Connect (OSTI)

    1996-01-30

    This is the final technical report on a commercialization project for an air conditioning heat pump water heater. The objective of the project was to produce a saleable system which would be economically competitive with natural gas and cost effective with regard to initial cost versus annual operating costs. The development and commercialization of the system is described.

  3. Building America Technology Solutions for New and Existing Homes: Multifamily Central Heat Pump Water Heaters (Fact Sheet)

    Broader source: Energy.gov [DOE]

    To evaluate the performance of central heat pump water heaters for multifamily applications, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California, for 16 months.

  4. 2014-10-14 Issuance: Test Procedures and Energy Conservation Standards for Residential Solar Water Heaters; Request for Information

    Broader source: Energy.gov [DOE]

    This document is a pre-publication Federal Register request for information regarding test procedures and energy conservation standards for residential solar water heaters, as issued by the Deputy Assistant Secretary for Energy Efficiency on October 14, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

  5. Corrosion-related failures in feedwater heaters. Final report

    SciTech Connect (OSTI)

    Beavers, J.A.; Agrawal, A.K.; Berry, W.E.

    1983-07-01

    A survey of the literature was performed for the Electric Power Research Institute on corrosion-related failures in feedwater heaters. The survey was directed toward failures in fossil and in pressurized water reactor (PWR) nuclear power plants, but includes some pertinent information related to failures in boiling water reactor (BWR) power plants. The survey was organized into sections on the commonly used feedwater heater materials; C steel, brasses, Cu-Ni alloys, MONEL Alloy 400, and Type 304 Stainless Steel. A section on Ti as a potential feedwater heater material also is given in the appendices. Each section is divided into subsections on field experience and laboratory studies tat relate to the field failures that have been observed. Appendices are given on a feedwater heater description, water quality in power plants, forms of corrosion, and failure analysis techniques.

  6. ISSUANCE 2015-03-27: Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment: Test Procedures for Consumer and Commercial Water Heaters, Notice of Proposed Rulemaking

    Office of Energy Efficiency and Renewable Energy (EERE)

    Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment: Test Procedures for Consumer and Commercial Water Heaters, Notice of Proposed Rulemaking

  7. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    SciTech Connect (OSTI)

    Not Available

    1993-11-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  8. Convective heater

    DOE Patents [OSTI]

    Thorogood, Robert M.

    1986-01-01

    A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

  9. Convective heater

    DOE Patents [OSTI]

    Thorogood, Robert M.

    1983-01-01

    A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

  10. Convective heater

    DOE Patents [OSTI]

    Thorogood, R.M.

    1983-12-27

    A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation. 14 figs.

  11. Accuracy of the European solar water heater test procedure. Part 2: Prediction of long-term performance

    SciTech Connect (OSTI)

    Rabl, A. ); Carvalho, M.J.; Collares-Pereira, M. ); Bourges, B.

    1991-01-01

    This paper continues the evaluation of the European test procedure for solar water heaters, by considering what consequences the errors of the parameters (derived in Part 1, the companion paper) will have for the prediction of the long-term performance. A simple criterion is derived for the required length of the test period, as a function of climatic variables and desired accuracy of the long-term performance prediction. Typically a duration of 10 to 50 days will suffice. Since the actual conditions during a test cannot be foreseen, it will be more efficient to calculate the error of the long-term performance prediction on line at the end of each test day and terminate the series whenever acceptable accuracy is reached.

  12. Performance of Gas-fired Water Heaters in a 10-home Field Study

    Broader source: Energy.gov [DOE]

    This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "Are high-efficiency hot water heating systems worth the cost?"

  13. CO2 Conversion By Nano Heaters

    ScienceCinema (OSTI)

    None

    2014-06-23

    A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

  14. CO2 Conversion By Nano Heaters

    SciTech Connect (OSTI)

    2014-03-11

    A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

  15. Bounding Limitations in the Practical Design of Adsorption Heat Pump Water Heaters

    SciTech Connect (OSTI)

    Ally, Moonis Raza; Sharma, Vishaldeep; Gluesenkamp, Kyle R

    2016-01-01

    The boundary temperatures for any sorption-based technology can be estimated on the basis of Trouton s hypothesis that isosteres, extrapolated to infinite pressure (or analogously to infinite temperature) meet at a single point. In this paper we discuss the consequences of this hypothesis for many sorption devices that are thermally operated, suitable for exploiting renewable energy resources, or making better use of high or low level thermal energy. Trouton s hypothesis is independent of the working fluids making it particularly useful to both liquid-vapor and solid-vapor systems. We exemplify the use of the derived boundary temperatures derived from Trouton s hypothesis to important processes such as ice making, space cooling in hot climates, deep freezing, and residential hot water production. The boundary temperatures help determine which sorption or solar heating technology may be better suited to serve the given application, or whether it is beyond the scope of sorption systems.

  16. Gas Swimming Pool Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    How They Work Gas pool heaters use either natural gas or propane. As the pump circulates the pool's water, the water drawn from the pool passes through a filter and then to the ...

  17. Residential Water Heaters Webinar

    Broader source: Energy.gov (indexed) [DOE]

    ENERGY LABORATORY Technology Overview - Condensing Storage * Fuels: Natural Gas, Propane * Much greater surface area of flue pipe, more heat transfer and combustion gases...

  18. Solar Water Heater Rebate

    Office of Energy Efficiency and Renewable Energy (EERE)

    Residential utility customers in Hawaii, Honolulu, and Maui counties can choose between a direct upfront rebate of $1,000 or a $1,000 interest rate buydown. They cannot receive both. The upfront...

  19. Portable solar heater

    SciTech Connect (OSTI)

    Kilar, L.J.

    1981-08-18

    A portable solar heater combines a self-contained hot air and heat storage system having a collector area with adjustable reflectors in a unit that can be moved from room to room as needed. The heater has fans for circulation of the solar heater air and provides both direct and indirect heat transfer to the ambient room air.

  20. NREL: Water Power Research - Research Staff

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    A photo of beep blue ocean water with small waves rolling across the surface of the water. Photo courtesy of grapestock, iStockphoto Research Staff Here you will find contact ...

  1. Water Heating Basics | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating Basics Water Heating Basics August 19, 2013 - 11:15am Addthis A variety of systems are available for water heating in homes and buildings. Learn about: Conventional Storage Water Heaters Demand (Tankless or Instantaneous) Water Heaters Heat Pump Water Heaters Solar Water Heaters Tankless Coil and Indirect Water Heaters Addthis Related Articles Tankless Demand Water Heater Basics Solar Water Heater Basics Heat Pump Water Heater Basics Energy Basics Home Renewable Energy Homes &

  2. Packaged die heater

    DOE Patents [OSTI]

    Spielberger, Richard; Ohme, Bruce Walker; Jensen, Ronald J.

    2011-06-21

    A heater for heating packaged die for burn-in and heat testing is described. The heater may be a ceramic-type heater with a metal filament. The heater may be incorporated into the integrated circuit package as an additional ceramic layer of the package, or may be an external heater placed in contact with the package to heat the die. Many different types of integrated circuit packages may be accommodated. The method provides increased energy efficiency for heating the die while reducing temperature stresses on testing equipment. The method allows the use of multiple heaters to heat die to different temperatures. Faulty die may be heated to weaken die attach material to facilitate removal of the die. The heater filament or a separate temperature thermistor located in the package may be used to accurately measure die temperature.

  3. Dampers for Natural Draft Heaters: Technical Report

    SciTech Connect (OSTI)

    Lutz, James D.; Biermayer, Peter; King, Derek

    2008-10-27

    Energy required for water heating accounts for approximately 40percent of national residential natural gas consumption in California. With water heating contributing such a substantial portion of natural gas consumption, it is important to pay attention to water heater efficiencies. This paper reports on an investigation of a patented, buoyancy-operated flue damper. It is an add-on design to a standard atmospherically vented natural-draft gas-fired storage water heater. The flue damper was expected to reduce off-cycle standby losses, which would lead to improvements in the efficiency of the water heater. The test results showed that the Energy Factor of the baseline water heater was 0.576. The recovery efficiency was 0.768. The standby heat loss coefficient was 10.619 (BTU/hr-oF). After the damper was installed, the test results show an Energy Factor for the baseline water heater of 0.605. The recovery efficiency was 0.786. The standby heat loss coefficient was 9.135 (BTU/hr-oF). The recovery efficiency increased 2.3percent and the standby heat loss coefficient decreased 14percent. When the burner was on, the baseline water heater caused 28.0 CFM of air to flow from the room. During standby, the flow was 12.4 CFM. The addition of the damper reduced the flow when the burner was on to 23.5 CFM. During standby, flow with the damper was reduced to 11.1 CFM. The flue damper reduced off-cycle standby losses, and improved the efficiency of the water heater. The flue damper also improved the recovery efficiency of the water heater by restricting on-cycle air flows through the flue.With or without the flue damper, off-cycle air flow upthe stack is nearly half the air flow rate as when the burner is firing.

  4. Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Performance of a Heat Pump Water Heater in the Hot-Humid Climate Windermere, Florida Over recent years, heat pump water heaters (HPWHs) have become more read- ily available and more widely adopted in the marketplace. A key feature of an HPWH unit is that it is a hybrid system. When conditions are favorable, the unit will operate in heat pump mode (using a vapor compression system that extracts heat from the surrounding air) to effciently provide domestic hot water (DHW). Homeowners need not

  5. Water Heating Products and Services | Department of Energy

    Energy Savers [EERE]

    Find ENERGY STAR Gas Tankless Water Heaters ENERGY STAR Find ENERGY STAR Heat Pump Water Heaters ENERGY STAR Find ENERGY STAR Solar Water Heaters ENERGY STAR Find Product ...

  6. Portable solar heater structure

    SciTech Connect (OSTI)

    Holley, D.; Holley, D.E.

    1981-09-08

    Portable solar heater structure is described. A substantially rectangular frame has a back with openings therethrough for permitting air to be drawn into the solar heater. A layer of insulating materials is in contact with the back. A plurality of cupshaped solar collectors open toward the front of the solar heater structure are positioned adjacent the insulating material. A cover is over the front of the solar heater having openings therein adjacent the top thereof through which air heated by the solar heater is passed. A passage is between the openings in the back and cover of the solar heater through which relatively cool air is drawn through the openings in the back over the collectors to be heated for subsequent withdrawal through the openings in the cover.

  7. Grouped exposed metal heaters

    DOE Patents [OSTI]

    Vinegar, Harold J.; Coit, William George; Griffin, Peter Terry; Hamilton, Paul Taylor; Hsu, Chia-Fu; Mason, Stanley Leroy; Samuel, Allan James; Watkins, Ronnie Wade

    2012-07-31

    A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

  8. Grouped exposed metal heaters

    DOE Patents [OSTI]

    Vinegar, Harold J.; Coit, William George; Griffin, Peter Terry; Hamilton, Paul Taylor; Hsu, Chia-Fu; Mason, Stanley Leroy; Samuel, Allan James; Watkins, Ronnie Wade

    2010-11-09

    A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

  9. Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater Part 1: Southern and South Central Climate Zones

    SciTech Connect (OSTI)

    Geoghegan, Patrick J; Shen, Bo; Keinath, Christopher M.; Garrabrant, Michael A.

    2016-01-01

    Commercial hot water heating accounts for approximately 0.78 Quads of primary energy use with 0.44 Quads of this amount from natural gas fired heaters. An ammonia-water based commercial absorption system, if fully deployed, could achieve a high level of savings, much higher than would be possible by conversion to the high efficiency nonheat-pump gas fired alternatives. In comparison with air source electric heat pumps, the absorption system is able to maintain higher coefficients of performance in colder climates. The ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. A thermodynamic model of a single effect ammonia-water absorption system for commercial space and water heating was developed, and its performance was investigated for a range of ambient and return water temperatures. This allowed for the development of a performance map which was then used in a building energy modeling software. Modeling of two commercial water heating systems was performed; one using an absorption heat pump and another using a condensing gas storage system. The energy and financial savings were investigated for a range of locations and climate zones in the southern and south central United States. A follow up paper will analyze northern and north/central regions. Results showed that the system using an absorption heat pump offers significant savings.

  10. Water Heating | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Public Services Homes Water Heating Water Heating Infographic: Water Heaters 101 Infographic: Water Heaters 101 Everything you need to know about saving money on water...

  11. NREL and Industry Advance Low-Cost Solar Water Heating R&D (Fact Sheet), NREL Highlights in Research & Development, NREL (National Renewable Energy Laboratory)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    NREL and Rhotech develop cost-effective solar water heating prototype to rival natural gas water heaters. Water heating energy use represents the second largest energy demand for homes nationwide, offering an opportunity for innovative solar water heating (SWH) technologies to offset energy use and costs. In the Low-Cost Solar Water Heating Research and Development Roadmap, researchers at the National Renewable Energy Laboratory (NREL) outlined a strategy to expand the SWH market. Recognizing

  12. Research & Development Roadmap: Emerging Water Heating Technologies...

    Office of Environmental Management (EM)

    Water Heating Technologies Research & Development Roadmap: Emerging Water Heating Technologies The Research and Development (R&D) Roadmap for Emerging Water Heating Technologies ...

  13. Portable kerosene heater controversy

    SciTech Connect (OSTI)

    Decker, M.O.

    1982-04-01

    The National Kerosene Heater Association reports sales of slightly fewer than two million heaters in the United States between 1975 and 1979. More than one million were sold in 1980 and they project sales of eight to ten million by 1985. Kerosene heater dealers are urged to post warnings to customers specifying the grade of kerosene to be used. 1-K kerosene has a maximum sulfur content of .04% and is generally suitable for use in nonflue-connected burners. 2-K kerosene, with a sulfur content of as much as .30% should be used only in flue-connected burner applications. (JMT)

  14. Explosives tester with heater

    DOE Patents [OSTI]

    Del Eckels, Joel; Nunes, Peter J.; Simpson, Randall L.; Whipple, Richard E.; Carter, J. Chance; Reynolds, John G.

    2010-08-10

    An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.

  15. Water Research and Technology | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Argonne OutLoud: The End of Water As We Know It Argonne OutLoud: The End of Water As We Know It (Jan. 28, 2016) Water Research and Technology Water Research and Technology Our ...

  16. NREL: Water Power Research Home Page

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water Power Research NREL's water power technologies research leverages 35 years of experience developing renewable energy technologies to support the U.S. Department of Energy ...

  17. NEXT GENERATION COMMERCIAL HEAT PUMPWATER HEATER USING CARBON DIOXIDE USING DIFFERENT IMPROVEMENT APPROACHES

    SciTech Connect (OSTI)

    Chad Bowers; Michael Petersen; Stefan Elbel; Pega Hrnjak

    2012-04-01

    Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82?ºC, as required by sanitary codes in the U.S. (Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35 kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20 %.

  18. Experimental studies on heat transfer and friction factor characteristics of forced circulation solar water heater system fitted with helical twisted tapes

    SciTech Connect (OSTI)

    Jaisankar, S.; Radhakrishnan, T.K.; Sheeba, K.N.

    2009-11-15

    Experimental investigation of heat transfer, friction factor and thermal performance of twisted tape solar water heater with various twist ratios has been conducted and the results are compared with plain tube collector for the same operating conditions with Reynolds number varied from 3000 to 23,000. Experimental data from plain tube collector is validated with the fundamental equations and found that the discrepancy is less than {+-}5.35% and {+-}8.80% for Nusselt number and friction factor, respectively. Correlations have been developed for Nusselt number and friction factor with various twist ratios (Y = 3, 4, 5, 6) and are compared with the experimental values. Results conclude that, heat transfer and pressure drop are higher in twisted tape collector compared to the plain one. Among the various twist ratios, the minimum twist ratio 3 is found to enhance the heat transfer and pressure drop due to swirl generation. As the twist ratio increases, the swirl generation decreases and minimizes the heat transfer and friction factor. (author)

  19. Water Heating | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating Water Heating Infographic: Water Heaters 101 Infographic: Water Heaters 101 Everything you need to know about saving money on water heating costs. Read more Selecting a New Water Heater Selecting a New Water Heater Tankless? Storage? Solar? Save money on your water heating bill by choosing the right type of energy-efficient water heater for your needs. Read more Sizing a New Water Heater Sizing a New Water Heater When buying a new water heater, bigger is not always better. Learn

  20. Solar Swimming Pool Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Swimming Pool Heaters Solar Swimming Pool Heaters An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by...

  1. Hot gas engine heater head

    DOE Patents [OSTI]

    Berntell, John O.

    1983-01-01

    A heater head for a multi-cylinder double acting hot gas engine in which each cylinder is surrounded by an annular regenerator unit, and in which the tops of each cylinder and its surrounding regenerator are interconnected by a multiplicity of heater tubes. A manifold for the heater tubes has a centrally disposed duct connected to the top of the cylinder and surrounded by a wider duct connecting the other ends of the heater tubes with the regenerator unit.

  2. NREL: Water Power Research - Webmaster

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Webmaster Please enter your name and email address in the boxes provided, then type your message below. When you are finished, click "Send Message." NOTE: If you enter your e-mail address incorrectly, we will be unable to reply. Your name: Your email address: Your message: Send Message Printable Version Water Power Research Home Capabilities Projects Research Staff Publications Working with Us News Did you find what you needed? Yes 1 No 0 Thank you for your feedback. Would you like to

  3. Development of a gas backup heater for solar domestic hot-water systems. Final report, April 1978-April 1980

    SciTech Connect (OSTI)

    Morrison, D.J.; Grunes, H.E.; de Winter, F.; Armstrong, P.R.

    1980-06-01

    A comprehensive program was undertaken to develop a unique gas fired backup for solar domestic hot water systems. Detailed computer design tools were written. A series of heat transfer experiments were performed to characterize the performance of individual components. A full scale engineering prototype, including the solar preheat tank and solar heat exchanger, was designed, fabricated and subjected to limited testing. Firing efficiency for the backup system was found to be 81.4% at a firing rate of 50,000 Btu/h. Long term standby losses should be negligible.

  4. NREL: Water Power Research - News

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    News Below are news stories related to NREL water power research. Subscribe to the RSS feed RSS . Learn about RSS. August 18, 2016 NREL Announces Round Two Selections for the DOE Small Business Vouchers Pilot The Energy Department's (DOE) National Renewable Energy Laboratory (NREL) will help 12 companies advance their technologies under the second round of DOE's Small Business Vouchers (SBV) pilot. July 22, 2016 NREL's Kurtz, Tegen Honored for Clean Energy Leadership The U.S. Clean Energy

  5. NREL: Water Power Research - Publications

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Publications Access NREL publications on water power research. Snowberg, D., and Weber, J. 2015. Marine and Hydrokinetic Technology Development Risk Management Framework. NREL/TP-5000-63258. National Renewable Energy Laboratory (NREL), Golden, CO (US). Tom, N., Lawson, M., Yu, Y., and Wright, A. 2015. Preliminary Analysis of an Oscillating Surge Wave Energy Converter with Controlled Geometry: Preprint. NREL/CP-5000-64545. NREL, Golden, CO (US). Jenne, D. S.,Yu, Y. H., and Neary, V. 2015.

  6. Immersible solar heater for fluids

    DOE Patents [OSTI]

    Kronberg, James W.

    1995-01-01

    An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

  7. Low-Cost Solar Water Heating Research and Development Roadmap

    SciTech Connect (OSTI)

    Hudon, K.; Merrigan, T.; Burch, J.; Maguire, J.

    2012-08-01

    The market environment for solar water heating technology has changed substantially with the successful introduction of heat pump water heaters (HPWHs). The addition of this energy-efficient technology to the market increases direct competition with solar water heaters (SWHs) for available energy savings. It is therefore essential to understand which segment of the market is best suited for HPWHs and focus the development of innovative, low-cost SWHs in the market segment where the largest opportunities exist. To evaluate cost and performance tradeoffs between high performance hot water heating systems, annual energy simulations were run using the program, TRNSYS, and analysis was performed to compare the energy savings associated with HPWH and SWH technologies to conventional methods of water heating.

  8. Water Technology Research | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water Technology Research Wastewater treatment plant Wastewater treatment plant Water is an increasingly valuable natural resource. By identifying typical sources and distribution ...

  9. Heat Pump Swimming Pool Heaters

    Broader source: Energy.gov [DOE]

    If you want an energy-efficient way to heat your swimming pool, consider using a heat pump pool heater in mild climates.

  10. Regenerative air heater

    DOE Patents [OSTI]

    Hasselquist, Paul B.; Baldner, Richard

    1982-01-01

    A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

  11. Regenerative air heater

    DOE Patents [OSTI]

    Hasselquist, P.B.; Baldner, R.

    1980-11-26

    A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

  12. Researching power plant water recovery

    SciTech Connect (OSTI)

    2008-04-01

    A range of projects supported by NETl under the Innovations for Existing Plant Program are investigating modifications to power plant cooling systems for reducing water loss, and recovering water from the flue gas and the cooling tower. This paper discusses two technologies showing particular promise condense water that is typically lost to evaporation, SPX technologies' Air2Air{sup trademark} condenses water from a cooling tower, while Lehigh University's process condenses water and acid in flue gas. 3 figs.

  13. Gas Swimming Pool Heaters | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Gas Swimming Pool Heaters Gas-fired pool heaters remain the most popular system for heating swimming pools. Today you can find new gas-fired heater models with much higher...

  14. Subsurface heaters with low sulfidation rates

    DOE Patents [OSTI]

    John, Randy Carl; Vinegar, Harold J

    2013-12-10

    A system for heating a hydrocarbon containing formation includes a heater having an elongated ferromagnetic metal heater section. The heater is located in an opening in a formation. The heater section is configured to heat the hydrocarbon containing formation. The exposed ferromagnetic metal has a sulfidation rate that goes down with increasing temperature of the heater, when the heater is in a selected temperature range.

  15. Immersible solar heater for fluids

    DOE Patents [OSTI]

    Kronberg, J.W.

    1995-07-11

    An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

  16. Immersible solar heater for fluids

    DOE Patents [OSTI]

    Hazen, T.C.; Fliermans, C.B.

    1994-01-01

    An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

  17. Process Heater for Stoichiometric Combustion Control | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heater for Stoichiometric Combustion Control Process Heater for Stoichiometric Combustion Control An Enhanced, CO-Based, Low Excess Air Control System Saves Energy While Reducing ...

  18. Advanced Water Technologies | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water We're developing ways to purify and conserve this vital resource. Take a look at our work. Home > Innovation > Water Innovation 247: We're Always Open At GE Global Research, ...

  19. NREL: Water Power Research - Projects

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Projects NREL's water power R&D projects support industry efforts to develop and deploy cost-effective water power technologies and to better understand the value and potential of conventional hydropower generation and pumped storage hydropower facilities. Here are some examples of current R&D projects focused on achieving these objectives: Testing and Standards Computer-Aided Engineering Resource Characterization Economic and Power System Modeling and Analysis Printable Version Water

  20. NREL: Water Power Research - Working with Us

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Working with Us NREL works with industry in a public-private contracting environment to research, design, and build advanced water power technologies. NREL's National Wind ...

  1. NREL: Water Power Research - Capabilities

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Capabilities NREL supports the development of marine and hydrokinetic technologies and hydropower R&D through the U.S. Department of Energy's Water Power Program. Our activities span a wide spectrum of disciplines, including fluid mechanics; dynamics, structures, and fatigue; power systems and electronics; resource assessment and mapping; economic analysis; and grid interconnection. Read more about NREL's water power R&D capabilities: Design Review and Analysis Device and Component

  2. Methods for forming long subsurface heaters

    DOE Patents [OSTI]

    Kim, Dong Sub

    2013-09-17

    A method for forming a longitudinal subsurface heater includes longitudinally welding an electrically conductive sheath of an insulated conductor heater along at least one longitudinal strip of metal. The longitudinal strip is formed into a tubular around the insulated conductor heater with the insulated conductor heater welded along the inside surface of the tubular.

  3. Portable Heaters | Department of Energy

    Energy Savers [EERE]

    Space heater capacities generally range between 10,000 Btu and 40,000 Btu per hour, and commonly run on electricity, propane, natural gas, and kerosene (see wood and pellet heating ...

  4. Heater head for stirling engine

    DOE Patents [OSTI]

    Corey, John A.

    1985-07-09

    A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

  5. High Efficiency, Ultra-Low Emission, Integrated Process Heater System

    SciTech Connect (OSTI)

    Mason, Howard; Boral, Anindya; Chhotray, San; Martin, Matthew

    2006-06-19

    The team of TIAX LLC, ExxonMobil Research and Engineering Company, and Callidus Technologies, LLC conducted a six-year program to develop an ultra-low emission process heater burner and an advanced high efficiency heater design. This project addresses the critical need of process heater operators for reliable, economical emission reduction technologies to comply with stringent emission regulations, and for heater design alternatives that reduce process heater energy requirements without significant cost increase. The key project targets were NOx emissions of 10 ppm (@ 3% O2), and a heater thermal efficiency of 95 percent. The ultra low NOx burner was developed through a series of pilot-scale and field tests combined with computational fluid dynamic modeling to arrive at simultaneous low emissions and suitable flame shape and stability. Pilot scale tests were run at TIAX, at the 2 MMBtu/hr scale, and at Callidus at 8 MMBtu/hr. The full scale burner was installed on a 14 burner atmospheric pipestill furnace at an ExxonMobil refinery. A variety of burner configurations, gas tips and flame stabilizers were tested to determine the lowest emissions with acceptable flame shape and stability. The resulting NOx emissions were 22 ppm on average. Starting in 2001, Callidus commercialized the original ultra low NOx burner and made subsequent design improvements in a series of commercial burners evolving from the original concept and/or development. Emissions in the field with the ultra low-NOx burner over a broad spectrum of heater applications have varied from 5 ppm to 30 ppm depending on heater geometry, heater service, fuel and firing capacity. To date, 1550 of the original burners, and 2500 of subsequent generation burners have been sold by Callidus. The advanced heater design was developed by parametric evaluations of a variety of furnace and combustion air preheater configurations and technologies for enhancing convective and radiative heat transfer. The design evolution

  6. Phase change material storage heater

    DOE Patents [OSTI]

    Goswami, D. Yogi; Hsieh, Chung K.; Jotshi, Chand K.; Klausner, James F.

    1997-01-01

    A storage heater for storing heat and for heating a fluid, such as water, has an enclosure defining a chamber therein. The chamber has a lower portion and an upper portion with a heating element being disposed within the enclosure. A tube through which the fluid flows has an inlet and an outlet, both being disposed outside of the enclosure, and has a portion interconnecting the inlet and the outlet that passes through the enclosure. A densely packed bed of phase change material pellets is disposed within the enclosure and is surrounded by a viscous liquid, such as propylene glycol. The viscous liquid is in thermal communication with the heating element, the phase change material pellets, and the tube and transfers heat from the heating element to the pellets and from the pellets to the tube. The viscous fluid has a viscosity so that the frictional pressure drop of the fluid in contact with the phase change material pellets substantially reduces vertical thermal convection in the fluid. As the fluid flows through the tube heat is transferred from the viscous liquid to the fluid flowing through the tube, thereby heating the fluid.

  7. Research & Development Roadmap: Emerging Water Heating Technologies

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Research and Development (R&D) Roadmap for Emerging Water Heating Technologies provides recommendations to the Building Technologies Office (BTO) on R&D activities to pursue that will aid in achieving BTO’s energy savings goals.

  8. California Tribal Nations Technical Water Research

    SciTech Connect (OSTI)

    Ben, C; Coty, J

    2005-08-15

    This research focused on identifying the key technical water issues of federally recognized California Native American tribes, the context within which these water issues arise for the tribes, and an appropriate format for potentially opening further dialogue on water research issues between the tribes and Lawrence Livermore National Laboratory (LLNL) scientists. At LLNL, a Water Quality and Resource Management Issues Workshop held in January of 2003 resulted in multiple recommendations, one proposing a LLNL dialogue with California tribes to further inform LLNL's prioritization of water issues based on identified needs across national sectors. The focus of this aforementioned Water Quality and Resource Management Issues Workshop was to identify national and international priority water research issues with which LLNL may align their research efforts and contribute to resolving these needs. LLNL staff researched various sectors to delineate the key water issues associated with each. This preliminary water issue research included diverse entities such as international water agencies, federal and state agencies, industry, non-governmental agencies, and private organizations. The key (identified) water issues across these sectors were presented to workshop attendees and used during workshop debates and sessions. However, the key water issues of federally recognized Native American tribes remained less understood, resulting in a workshop proposal for additional research and LLNL potentially hosting a dialog with representatives of these tribes. Federally recognized Native American tribes have a unique government-to-government relationship with the United States (U.S.) government, in contrast to other sectors researched for the workshop. Within the U.S., the number of federally recognized tribes currently stands at 562 and, in addition to this large number of tribes, much diversity across these tribes exists. For the purposes of this preliminary research and report, it

  9. Purchasing Energy-Efficient Residential Electric Storage Water...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy-Efficient Residential Electric Storage Water Heaters Purchasing Energy-Efficient Residential Electric Storage Water Heaters The Federal Energy Management Program (FEMP) ...

  10. Frontiers of interfacial water research :workshop report.

    SciTech Connect (OSTI)

    Cygan, Randall Timothy; Greathouse, Jeffery A.

    2005-10-01

    Water is the critical natural resource of the new century. Significant improvements in traditional water treatment processes require novel approaches based on a fundamental understanding of nanoscale and atomic interactions at interfaces between aqueous solution and materials. To better understand these critical issues and to promote an open dialog among leading international experts in water-related specialties, Sandia National Laboratories sponsored a workshop on April 24-26, 2005 in Santa Fe, New Mexico. The ''Frontiers of Interfacial Water Research Workshop'' provided attendees with a critical review of water technologies and emphasized the new advances in surface and interfacial microscopy, spectroscopy, diffraction, and computer simulation needed for the development of new materials for water treatment.

  11. Gas Swimming Pool Heaters | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    and pool use, they may not be the most energy-efficient option when compared to heat pump and solar pool heaters. How They Work Gas pool heaters use either natural gas or...

  12. WPN 08-4: Space Heater Policy

    Broader source: Energy.gov [DOE]

    To update the policy relation to space heaters for the low-income Weatherization Assistance Program. This policy supersedes the previous space heater policy issued by memoranda on March 18, 1992.

  13. Tips: Water Heating | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating Tips: Water Heating Keep your energy bills out of hot water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even ...

  14. Welding shield for coupling heaters

    DOE Patents [OSTI]

    Menotti, James Louis

    2010-03-09

    Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.

  15. Field Testing of Pre-Production Prototype Residential Heat Pump Water

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heaters | Department of Energy Field Testing of Pre-Production Prototype Residential Heat Pump Water Heaters Field Testing of Pre-Production Prototype Residential Heat Pump Water Heaters Provides and overview of field testing of 18 pre-production prototype residential heat pump water heaters heat_pump_water_heater_testing.pdf (565.45 KB) More Documents & Publications Building America Technology Solutions for New and Existing Homes: Performance of a Heat Pump Water Heater in the Hot-Humid

  16. Silicon photonic heater-modulator

    DOE Patents [OSTI]

    Zortman, William A.; Trotter, Douglas Chandler; Watts, Michael R.

    2015-07-14

    Photonic modulators, methods of forming photonic modulators and methods of modulating an input optical signal are provided. A photonic modulator includes a disk resonator having a central axis extending along a thickness direction of the disk resonator. The disk resonator includes a modulator portion and a heater portion. The modulator portion extends in an arc around the central axis. A PN junction of the modulator portion is substantially normal to the central axis.

  17. Adjusting alloy compositions for selected properties in temperature limited heaters

    DOE Patents [OSTI]

    Brady; Michael Patrick , Horton, Jr.; Joseph Arno , Vitek; John Michael

    2010-03-23

    Heaters for treating a subsurface formation are described herein. Such heaters can be obtained by using the systems and methods described herein. The heater includes a heater section including iron, cobalt, and carbon. The heater section has a Curie temperature less than a phase transformation temperature. The Curie temperature is at least 740.degree. C. The heater section provides, when time varying current is applied to the heater section, an electrical resistance.

  18. End Calorimeter Warm Tube Heater

    SciTech Connect (OSTI)

    Primdahl, K.; /Fermilab

    1991-08-06

    The Tevatron accelerator beam tube must pass through the End Calorimeter cryostats of the D-Zero Collider Detector. Furthermore, the End Calorimeter cryostats must be allowed to roll back forty inches without interruption of the vacuum system; hence, the Tev tube must slide through the End Calorimeter cryostat as it is rolled back. The Tev pass through the End Calorimeter can actually be thought of as a cluster of concentric tubes: Tev tube, warm (vacuum vessel) tube, IS layers of superinsulation, cold tube (argon vessel), and Inner Hadronic center support tube. M. Foley generated an ANSYS model to study the heat load. to the cryostat. during collider physics studies; that is, without operation of the heater. A sketch of the model is included in the appendix. The vacuum space and superinsulation was modeled as a thermal solid, with conductivity derived from tests performed at Fermilab. An additional estimate was done. by this author, using data supplied by NR-2. a superinsulation manufacturer. The ANSYS result and hand calculation are in close agreement. The ANSYS model was modified. by this author. to incorporate the effect of the heater. Whereas the earlier model studied steady state operation only. the revised model considers the heater-off steady state mode as the initial condition. then performs a transient analysis with a final load step for time tending towards infinity. Results show the thermal gradient as a function of time and applied voltage. It should be noted that M. Foley's model was generated for one half the warm tube. implying the tube to be symmetric. In reality. the downstream connection (relative to the collision point) attachment to the vacuum shell is via several convolutions of a 0.020-inch wall bellows; hence. a nearly adiabatic boundary condition. Accordingly. the results reported in the table reflect extrapolation of the curves to the downstream end of the tube. Using results from the ANSYS analysis, that is, tube temperature and

  19. Joint used for coupling long heaters

    DOE Patents [OSTI]

    Menottie, James Louis

    2013-02-26

    Systems for coupling ends of elongated heaters and methods of using such systems to treat a subsurface formation are described herein. A system may include two elongated heaters with an end portion of one heater abutted or near to an end portion of the other heater and a core coupling material. The core coupling material may extend between the two elongated heaters. The elongated heaters may include cores and at least one conductor substantially concentrically surrounds the cores. The cores may have a lower melting point than the conductors. At least one end portion of the conductor may have a beveled edge. The gap formed by the beveled edge may be filled with a coupling material for coupling the one or more conductors. One end portion of at least one core may have a recessed opening and the core coupling material may be partially inside the recessed opening.

  20. Supercritical Water Reactor (SCWR) - Survey of Materials Research and Development Needs to Assess Viability

    SciTech Connect (OSTI)

    Philip E. MacDonald

    2003-09-01

    Supercritical water-cooled reactors (SCWRs) are among the most promising advanced nuclear systems because of their high thermal efficiency [i.e., about 45% vs. 33% of current light water reactors (LWRs)] and considerable plant simplification. SCWRs achieve this with superior thermodynamic conditions (i.e., high operating pressure and temperature), and by reducing the containment volume and eliminating the need for recirculation and jet pumps, pressurizer, steam generators, steam separators and dryers. The reference SCWR design in the U.S. is a direct cycle, thermal spectrum, light-water-cooled and moderated reactor with an operating pressure of 25 MPa and inlet/outlet coolant temperature of 280/500 °C. The inlet flow splits, partly to a down-comer and partly to a plenum at the top of the reactor pressure vessel to flow downward through the core in special water rods to the inlet plenum. This strategy is employed to provide good moderation at the top of the core, where the coolant density is only about 15-20% that of liquid water. The SCWR uses a power conversion cycle similar to that used in supercritical fossil-fired plants: high- intermediate- and low-pressure turbines are employed with one moisture-separator re-heater and up to eight feedwater heaters. The reference power is 3575 MWt, the net electric power is 1600 MWe and the thermal efficiency is 44.8%. The fuel is low-enriched uranium oxide fuel and the plant is designed primarily for base load operation. The purpose of this report is to survey existing materials for fossil, fission and fusion applications and identify the materials research and development needed to establish the SCWR viabilitya with regard to possible materials of construction. The two most significant materials related factors in going from the current LWR designs to the SCWR are the increase in outlet coolant temperature from 300 to 500 °C and the possible compatibility issues associated with the supercritical water environment.

  1. Parallel heater system for subsurface formations

    DOE Patents [OSTI]

    Harris, Christopher Kelvin (Houston, TX); Karanikas, John Michael (Houston, TX); Nguyen, Scott Vinh (Houston, TX)

    2011-10-25

    A heating system for a subsurface formation is disclosed. The system includes a plurality of substantially horizontally oriented or inclined heater sections located in a hydrocarbon containing layer in the formation. At least a portion of two of the heater sections are substantially parallel to each other. The ends of at least two of the heater sections in the layer are electrically coupled to a substantially horizontal, or inclined, electrical conductor oriented substantially perpendicular to the ends of the at least two heater sections.

  2. Combustion heater for oil shale

    DOE Patents [OSTI]

    Mallon, Richard G.; Walton, Otis R.; Lewis, Arthur E.; Braun, Robert L.

    1985-01-01

    A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650.degree.-700.degree. C. for use as a process heat source.

  3. Combustion heater for oil shale

    DOE Patents [OSTI]

    Mallon, R.; Walton, O.; Lewis, A.E.; Braun, R.

    1983-09-21

    A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650 to 700/sup 0/C for use as a process heat source.

  4. SINGLE HEATER TEST FINAL REPORT

    SciTech Connect (OSTI)

    J.B. Cho

    1999-05-01

    The Single Heater Test is the first of the in-situ thermal tests conducted by the U.S. Department of Energy as part of its program of characterizing Yucca Mountain in Nevada as the potential site for a proposed deep geologic repository for the disposal of spent nuclear fuel and high-level nuclear waste. The Site Characterization Plan (DOE 1988) contained an extensive plan of in-situ thermal tests aimed at understanding specific aspects of the response of the local rock-mass around the potential repository to the heat from the radioactive decay of the emplaced waste. With the refocusing of the Site Characterization Plan by the ''Civilian Radioactive Waste Management Program Plan'' (DOE 1994), a consolidated thermal testing program emerged by 1995 as documented in the reports ''In-Situ Thermal Testing Program Strategy'' (DOE 1995) and ''Updated In-Situ Thermal Testing Program Strategy'' (CRWMS M&O 1997a). The concept of the Single Heater Test took shape in the summer of 1995 and detailed planning and design of the test started with the beginning fiscal year 1996. The overall objective of the Single Heater Test was to gain an understanding of the coupled thermal, mechanical, hydrological, and chemical processes that are anticipated to occur in the local rock-mass in the potential repository as a result of heat from radioactive decay of the emplaced waste. This included making a priori predictions of the test results using existing models and subsequently refining or modifying the models, on the basis of comparative and interpretive analyses of the measurements and predictions. A second, no less important, objective was to try out, in a full-scale field setting, the various instruments and equipment to be employed in the future on a much larger, more complex, thermal test of longer duration, such as the Drift Scale Test. This ''shake down'' or trial aspect of the Single Heater Test applied not just to the hardware, but also to the teamwork and cooperation between

  5. Research Portfolio Report Small Producers: Environment and Water...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Environment and Water Management Cover image: Stored Wyoming Roll-out mats after unloading from truck. Research Portfolio Report Small Producers: Environment and Water Management ...

  6. Sandia, the Atlantic Council, and NM Water Resource Research...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the Atlantic Council, and NM Water Resource Research Institute Sponsor Roundtable on Western Water Scarcity - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us ...

  7. NETL Research: Energy and Water Interface

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water and Energy Interface Water and energy are inextricably linked. Because thermoelectric generation and fossil fuel extraction can impact water resources, it is critically...

  8. NETL Research: Energy and Water Interface

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water and Energy Interface Water and energy are inextricably linked. Because thermoelectric generation and fossil fuel extraction can impact water resources, it is critically ...

  9. Low-Cost Solar Water Heating Research and Development Roadmap

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cost Solar Water Heating Research and Development Roadmap K. Hudon, T. Merrigan, J. Burch ... No. DE-AC36-08GO28308 Low-Cost Solar Water Heating Research and Development Roadmap ...

  10. Marietta Power & Water- Residential Energy Efficiency Rebate

    Office of Energy Efficiency and Renewable Energy (EERE)

    Marietta Power & Water provides rebates for electric water heaters ($250) and electric and dual-fuel heat pumps ($150). If both a water heater and heat pump are installed simultaneously, a...

  11. Tips: Water Heating | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Keep your energy bills out of hot water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Keep your energy bills out...

  12. Subsurface connection methods for subsurface heaters

    DOE Patents [OSTI]

    Vinegar, Harold J.; Bass, Ronald Marshall; Kim, Dong Sub; Mason, Stanley Leroy; Stegemeier, George Leo; Keltner, Thomas Joseph; Carl, Jr., Frederick Gordon

    2010-12-28

    A system for heating a subsurface formation is described. The system includes a first elongated heater in a first opening in the formation. The first elongated heater includes an exposed metal section in a portion of the first opening. The portion is below a layer of the formation to be heated. The exposed metal section is exposed to the formation. A second elongated heater is in a second opening in the formation. The second opening connects to the first opening at or near the portion of the first opening below the layer to be heated. At least a portion of an exposed metal section of the second elongated heater is electrically coupled to at least a portion of the exposed metal section of the first elongated heater in the portion of the first opening below the layer to be heated.

  13. Evaluation of a Stirling engine heater bypass with the NASA Lewis nodal-analysis performance code

    SciTech Connect (OSTI)

    Sullivan, T.J.

    1986-05-01

    In support of the US Department of Energy's Stirling Engine Highway Vehicle Systems program, the NASA Lewis Research Center investigated whether bypassing the P-40 Stirling engine heater during regenerative cooling would improve the engine thermal efficiency. The investigation was accomplished by using the Lewis nodal-analysis Stirling engine computer model. Bypassing the P-40 Stirling engine heater at full power resulted in a rise in the indicated thermal efficiency from 40.6 to 41.0 percent. For the idealized (some losses not included) heater bypass that was analyzed, this benefit is not considered significant.

  14. Water reuse and technology | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water Reuse and the Energetic Connection Click to email this to a friend (Opens in new ... Water Reuse and the Energetic Connection Aymer Maturana 2015.05.28 Water scarcity is a ...

  15. Solar Hot Water Heater Industry in Barbados

    Broader source: Energy.gov [DOE]

    Energy Transition Initiative: Islands lesson learned detailing work done in the U.S. Virgin Islands.

  16. Tankless Water Heaters: Do They Really Work?

    Broader source: Energy.gov [DOE]

    This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on July 24-26, 2012.

  17. Solar Hot Water Heater Industry in Barbados

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of the SWH was appropriate for each household were crucial for maintaining suffcient ... Adams saw the beneft of the SWH when his annual gas consumption was reduced by 70%. With ...

  18. Strategy Guideline: Proper Water Heater Selection

    SciTech Connect (OSTI)

    Hoeschele, M.; Springer, D.; German, A.; Staller, J.; Zhang, Y.

    2012-08-01

    This document is no longer available. Please contact Cheryn.Metzger@nrel.gov for further information.

  19. Heat Pump Water Heater Performance in

    Broader source: Energy.gov [DOE]

    This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

  20. Xergy Develops Breakthrough Water Heater Compressor | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    This technique has several advantages over traditional mechanical heat pumps. While current heat pump technology is noisy and carries a high global warming impact, ECC uses ...

  1. Heat Pump Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Do the following when selecting a qualified professional: Request cost estimates in writing Ask for references Check the company with your local Better Business Bureau See if the ...

  2. Storage Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Be sure to do the following when selecting a contractor: Request cost estimates in writing Ask for references Check the company with your local Better Business Bureau See if the ...

  3. A small self-powered space heater

    SciTech Connect (OSTI)

    Menchen, W.R.; McAlonan, M.

    1995-12-31

    The work described combines the use of thermoelectric energy conversion with diesel burner technology, yielding a forced convection heater that does not require the use of external electric power. A heater of this type has both commercial and military application if, at reasonable cost, it is safe, portable and easy to operate. Self-powered refers to a design approach where part of the heat generated by a burner is used to produce all of the electrical power required to run system components. A successful self-powered heater requires careful attention to heat transfer and pressure drop so that power requirements and hence cost can be minimized.

  4. Particulate matter sensor with a heater

    DOE Patents [OSTI]

    Hall, Matthew

    2011-08-16

    An apparatus to detect particulate matter. The apparatus includes a sensor electrode, a shroud, and a heater. The electrode measures a chemical composition within an exhaust stream. The shroud surrounds at least a portion of the sensor electrode, exclusive of a distal end of the sensor electrode exposed to the exhaust stream. The shroud defines an air gap between the sensor electrode and the shroud and an opening toward the distal end of the sensor electrode. The heater is mounted relative to the sensor electrode. The heater burns off particulate matter in the air gap between the sensor electrode and the shroud.

  5. Access to Clean Water | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Clean Water Innovations Click to email this to a friend (Opens in new window) Share on ... What Works: Mark Little on Clean Water Innovations Mark Little, director of GE Global ...

  6. Water Heating Projects | Department of Energy

    Office of Environmental Management (EM)

    HVAC, Water Heating, & Appliances Water Heating Projects Water Heating Projects Figure 1: The system model for the combined Water heater, dehumidifier and cooler (WHDC). A ...

  7. Device for collecting emissions from kerosene heaters

    SciTech Connect (OSTI)

    Gilloti, N.J.

    1984-09-04

    An apparatus for both improving the heat distribution throughout a room from a portable kerosene heater and for collecting undesirable emissions resulting from the burning of the kerosene, includes a base adapted to be mounted on the top of the heater, the base supporting a vertically extending shaft on which is mounted a heat-driven fan formed of either paper or metal, and a disposable disk mounted a spaced distance above the fan on the same shaft, the disk serving as a collector for the undesirable emissions. When the device is placed on an operating kerosene heater, the rising hot air and gases from the heater cause the fan to rotate, which in turn causes emissions from the burning fuel to move upwardly in a more or less cylindrical path. As the products of combustion move upwardly, certain emissions therein such as soot, oily vapors, etc. deposit or condense onto the surface of the spinner and disposable disk.

  8. Heater head for a Stirling engine

    SciTech Connect (OSTI)

    Darooka, D.K.

    1988-09-06

    A heater head is described for a compound Stirling engine modules, each including a displacer cylinder coaxially aligned with the displacer cylinder of the other of the engine modules, a displacer piston mounted for reciprocation in the displacer cylinder.

  9. Small Space Heater Basics | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Space heater capacities generally range between 10,000 Btu to 40,000 Btu per hour. Common fuels used for this purpose are electricity, propane, natural gas, and kerosene. Although ...

  10. Varying properties along lengths of temperature limited heaters

    SciTech Connect (OSTI)

    Vinegar, Harold J.; Xie, Xueying; Miller, David Scott; Ginestra, Jean Charles

    2011-07-26

    A system for heating a subsurface formation is described. The system includes an elongated heater in an opening in the formation. The elongated heater includes two or more portions along the length of the heater that have different power outputs. At least one portion of the elongated heater includes at least one temperature limited portion with at least one selected temperature at which the portion provides a reduced heat output. The heater is configured to provide heat to the formation with the different power outputs. The heater is configured so that the heater heats one or more portions of the formation at one or more selected heating rates.

  11. Diesel particulate filter with zoned resistive heater

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI

    2011-03-08

    A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

  12. Consumer-products minimum energy-efficiency-standards program. Topical report on Subtask 3. 1. Evaluation of energy consumption savings of boost heaters in dishwashers

    SciTech Connect (OSTI)

    Not Available

    1980-05-01

    An analysis of the energy conservation and life cycle cost benefits of boost heaters for dishwashers is presented to provide technical information to assist in determining whether to modify the dishwasher test procedure to include boost heaters. Two manufacturers are offering dishwashers which have an inlet water temperature requirement of 120/sup 0/F. Cleaning performance in these appliances is maintained with an electric coil in the sump of the dishwasher, which boosts the incoming water to its final temperature. Both manufacturers have petitioned DOE for exemption from efficiency standards, since current DOE test procedures give no credit for water heater energy savings. The evaluation shows boost heaters to be energy conserving for all conditions. The life cycle cost analysis indicates boost heaters are cost effective in all cases for homes with electric water heaters, and in most cases for homes having gas water heaters. Additionally the proposed standards for dishwashers will lower water consumption in 1985 model dishwashers such that boost heaters will become cost effective in all cases.

  13. Performance Study of Swimming Pool Heaters

    SciTech Connect (OSTI)

    McDonald, R.J.

    2009-01-01

    The objective of this report is to perform a controlled laboratory study on the efficiency and emissions of swimming pool heaters based on a limited field investigation into the range of expected variations in operational parameters. Swimming pool heater sales trends have indicated a significant decline in the number of conventional natural gas-fired swimming pool heaters (NGPH). On Long Island the decline has been quite sharp, on the order of 50%, in new installations since 2001. The major portion of the decline has been offset by a significant increase in the sales of electric powered heat pump pool heaters (HPPH) that have been gaining market favor. National Grid contracted with Brookhaven National Laboratory (BNL) to measure performance factors in order to compare the relative energy, environmental and economic consequences of using one technology versus the other. A field study was deemed inappropriate because of the wide range of differences in actual load variations (pool size), geographic orientations, ground plantings and shading variations, number of hours of use, seasonal use variations, occupancy patterns, hour of the day use patterns, temperature selection, etc. A decision was made to perform a controlled laboratory study based on a limited field investigation into the range of expected operational variations in parameters. Critical to this are the frequency of use, temperature selection, and sizing of the heater to the associated pool heating loads. This would be accomplished by installing a limited amount of relatively simple compact field data acquisition units on selected pool installations. This data included gas usage when available and alternately heater power or gas consumption rates were inferred from the manufacturer's specifications when direct metering was not available in the field. Figure 1 illustrates a typical pool heater installation layout.

  14. Performance characterization of a hydrogen catalytic heater.

    SciTech Connect (OSTI)

    Johnson, Terry Alan; Kanouff, Michael P.

    2010-04-01

    This report describes the performance of a high efficiency, compact heater that uses the catalytic oxidation of hydrogen to provide heat to the GM Hydrogen Storage Demonstration System. The heater was designed to transfer up to 30 kW of heat from the catalytic reaction to a circulating heat transfer fluid. The fluid then transfers the heat to one or more of the four hydrogen storage modules that make up the Demonstration System to drive off the chemically bound hydrogen. The heater consists of three main parts: (1) the reactor, (2) the gas heat recuperator, and (3) oil and gas flow distribution manifolds. The reactor and recuperator are integrated, compact, finned-plate heat exchangers to maximize heat transfer efficiency and minimize mass and volume. Detailed, three-dimensional, multi-physics computational models were used to design and optimize the system. At full power the heater was able to catalytically combust a 10% hydrogen/air mixture flowing at over 80 cubic feet per minute and transfer 30 kW of heat to a 30 gallon per minute flow of oil over a temperature range from 100 C to 220 C. The total efficiency of the catalytic heater, defined as the heat transferred to the oil divided by the inlet hydrogen chemical energy, was characterized and methods for improvement were investigated.

  15. A Realistic Hot Water Draw Specification for Rating Solar Water...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Realistic Hot Water Draw Specification for Rating Solar Water Heaters Preprint J. Burch National Renewable Energy Laboratory J. Thornton Thermal Energy System Specialists, Inc. ...

  16. Temperature limited heaters using phase transformation of ferromagnetic material

    DOE Patents [OSTI]

    Vitek, John Michael [Oak Ridge, TN; Brady, Michael Patrick [Oak Ridge, TN

    2009-10-06

    Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.

  17. Sandia, the Atlantic Council, and NM Water Resource Research Institute

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Sponsor Roundtable on Western Water Scarcity the Atlantic Council, and NM Water Resource Research Institute Sponsor Roundtable on Western Water Scarcity - Sandia Energy Energy Search Icon Sandia Home Locations Contact Us Employee Locator Energy & Climate Secure & Sustainable Energy Future Stationary Power Energy Conversion Efficiency Solar Energy Wind Energy Water Power Supercritical CO2 Geothermal Natural Gas Safety, Security & Resilience of the Energy Infrastructure Energy

  18. Substrate heater for thin film deposition

    DOE Patents [OSTI]

    Foltyn, Steve R. (111 Beryl St., Los Alamos, NM 87544)

    1996-01-01

    A substrate heater for thin film deposition of metallic oxides upon a target substrate configured as a disk including means for supporting in a predetermined location a target substrate configured as a disk, means for rotating the target substrate within the support means, means for heating the target substrate within the support means, the heating means about the support means and including a pair of heating elements with one heater element situated on each side of the predetermined location for the target substrate, with one heater element defining an opening through which desired coating material can enter for thin film deposition and with the heating means including an opening slot through which the target substrate can be entered into the support means, and, optionally a means for thermal shielding of the heating means from surrounding environment is disclosed.

  19. NREL and Industry Advance Low-Cost Solar Water Heating R&D (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-08-01

    NREL and Rhotech develop cost-effective solar water heating prototype to rival natural gas water heater market.

  20. NREL: Water Power Research - Resource Characterization

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Resource Characterization Building on its success in wind resource characterization and assessment, the National Renewable Energy Laboratory (NREL) has extended its capabilities to the field of water power. NREL's team of scientists, engineers and computer experts has broad experience in physical oceanography, meteorology, modeling, data analysis, and Geographic Information Systems. Many years of experience in wind assessment have enabled NREL to develop the skills and methodologies to evaluate

  1. Energy-Efficiency & Water Institute Research Facility, Purdue University, (IN)

    SciTech Connect (OSTI)

    Nnanna, Agbai

    2015-01-30

    The renovation of the Schneider Avenue Building to construct two research laboratories within the building is complete. The research laboratories are for the Purdue Calumet Water Institute and the Energy Efficiency and Reliability Center. The Water Institute occupies approximately 1000+ SF of research space plus supporting offices. The Energy-Efficiency Center occupies approximately 1000+ SF that houses the research space. The labs will enhance the Water & Energy Institute’s research capabilities necessary to tackle these issues through the development of practical approaches critical to local government and industry. The addition of these research laboratories to the Purdue University Calumet campus is in both direct support of the University’s Strategic Plan as well as the 2008 Campus Master Plan that identifies a 20% shortage of research space.

  2. Heat Pump Swimming Pool Heaters | Department of Energy

    Energy Savers [EERE]

    Pump Swimming Pool Heaters Heat Pump Swimming Pool Heaters How a heat pump works. How a heat pump works. How They Work Heat pumps use electricity to capture heat and move it from ...

  3. NREL: Water Power Research - Testing and Standards

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Testing and Standards NREL's marine and hydrokinetics (MHK) testing activities provide industry partners with essential operational data on a wide variety of systems and components. This data helps researchers establish baseline cost and performance metrics and advance the technology readiness of those systems that demonstrate the greatest potential for successful commercial deployment. The development of standards leads to accelerated development, reduced risks, and increased access to capital.

  4. Heat Transfer Fluids for Solar Water Heating Systems | Department...

    Broader source: Energy.gov (indexed) [DOE]

    Illustration of a solar water heater. Illustration of a solar water heater. Heat-transfer fluids carry heat through solar collectors and a heat exchanger to the heat storage tanks...

  5. Fired heater for coal liquefaction process

    DOE Patents [OSTI]

    Ying, David H. S.

    1984-01-01

    A fired heater for a coal liquefaction process is constructed with a heat transfer tube having U-bends at regular intervals along the length thereof to increase the slug frequency of the multi-phase mixture flowing therethrough to thereby improve the heat transfer efficiency.

  6. An optimized periodic inspection program for condensers and feedwater heaters

    SciTech Connect (OSTI)

    Reinhart, E.R.; Kaminski, S.

    1996-12-31

    Tube failures in steam plant surface condensers and feedwater heaters are a significant reliability problem for the electric power industry. Tube failures can also result in an increase in replacement power costs. In addition, condenser leaks from failed tubes have potentially harmful effects on major components such as steam generators and turbines. To reduce the number of tube failures and consequent leakage, periodic maintenance programs have used the nondestructive evaluation (NDE) method of eddy-current testing (ET) to inspect the condition of the tubes from the water side. This NDE method can identify tubes that have experienced major degradation and should be plugged to prevent in-service failure. However, the use of NDE methods in plant maintenance of condensers and feedwater heaters is not standard practice and varies significantly throughout the utility industry. Variability of inspection results and difficulty in inspecting some types of tubing (monel, carbon steel) have caused many utility sites to question the value of in-service inspection of heat transfer tubing from the water side. Recognizing the above problem, advanced ET systems have been developed that use multi-frequency, remote field and digital data processing techniques to inspect a wide variety of tubing materials and produce on-site inspection reports. Recent field examination results will be presented.

  7. Research and Development Roadmap for Water Heating Technologies

    SciTech Connect (OSTI)

    Goetzler, William; Gagne, Claire; Baxter, Van D; Lutz, James; Merrigan, Tim; Katipamula, Srinivas

    2011-10-01

    Although water heating is an important energy end-use in residential and commercial buildings, efficiency improvements in recent years have been relatively modest. However, significant advancements related to higher efficiency equipment, as well as improved distribution systems, are now viable. DOE support for water heating research, development and demonstration (RD&D) could provide the impetus for commercialization of these advancements.

  8. HVAC, Water Heating, and Appliances Overview - 2015 BTO Peer Review |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Appliances Overview - 2015 BTO Peer Review HVAC, Water Heating, and Appliances Overview - 2015 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy View the Presentation HVAC, Water Heating, and Appliances Overview - 2015 BTO Peer Review (801.59 KB) More Documents & Publications HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heating, and Appliance Subprogram Overview - 2016 BTO Peer Review Research & Development Roadmap:

  9. Treating and Reusing Produced Water | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Researchers at OGTC Seek Sustainable Produced Water Management Solutions Click to email this to a friend (Opens in new window) Share on Facebook (Opens in new window) Click to share (Opens in new window) Click to share on LinkedIn (Opens in new window) Click to share on Tumblr (Opens in new window) Researchers at OGTC Seek Sustainable Produced Water Management Solutions Raymond Murphy 2015.04.28 Each year the US oil and gas industry generates around one trillion gallons of produced water as a

  10. Accelerated Life Structural Benchmark Testing for a Stirling Convertor Heater Head

    SciTech Connect (OSTI)

    Krause, David L.; Kantzos, Pete T.

    2006-01-20

    For proposed long-duration NASA Space Science missions, the Department of Energy, Lockheed Martin, Infinia Corporation, and NASA Glenn Research Center are developing a high-efficiency, 110-watt Stirling Radioisotope Generator (SRG110). A structurally significant limit state for the SRG110 heater head component is creep deformation induced at high material temperature and low stress level. Conventional investigations of creep behavior adequately rely on experimental results from uniaxial creep specimens, and a wealth of creep data is available for the Inconel 718 material of construction. However, the specified atypical thin heater head material is fine-grained with a heat treatment that limits precipitate growth, and little creep property data for this microstructure is available in the literature. In addition, the geometry and loading conditions apply a multiaxial stress state on the component, far from the conditions of uniaxial testing. For these reasons, an extensive experimental investigation is ongoing to aid in accurately assessing the durability of the SRG110 heater head. This investigation supplements uniaxial creep testing with pneumatic testing of heater head-like pressure vessels at design temperature with stress levels ranging from approximately the design stress to several times that. This paper presents experimental results, post-test microstructural analyses, and conclusions for four higher-stress, accelerated life tests. Analysts are using these results to calibrate deterministic and probabilistic analytical creep models of the SRG110 heater head.

  11. Eleana near-surface heater experiment final report

    SciTech Connect (OSTI)

    Lappin, A R; Thomas, R K; McVey, D F

    1981-04-01

    This report summarizes the results of a near-surface heater experiment operated at a depth of 23 m in argillite within the Eleana Formation on the Nevada Test Site (NTS). The test geometrically simulated emplacement of a single canister of High-Level Waste (HLW) and was operated at a power level of 2.5 kW for 21 days, followed by 3.8 kW to 250 days, when the power was turned off. Below 85 to 100{sup 0}C, there was good agreement between modeled and measured thermal results in the rock and in the emplacement hole, except for transient transport of water in the heater hole. Above 100{sup 0}C, modeled and measured thermal results increasingly diverged, indicating that the in-situ rock-mass thermal conductivity decreased as a result of dehydration more than expected on the basis of matrix properties. Correlation of thermomechanical modeling and field results suggests that this decrease was caused by strong coupling of thermal and mechanical behavior of the argillite at elevated temperatures. No hole-wall decrepitation was observed in the experiment; this fact and the codrrelation of modeled and measured results at lower temperatures indicate that there is no a priori reason to eliminate argillaceous rocks from further consideration as a host rock for nuclear wastes.

  12. Lid heater for glass melter

    DOE Patents [OSTI]

    Phillips, T.D.

    1993-12-14

    A glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes. 3 figures.

  13. Lid heater for glass melter

    DOE Patents [OSTI]

    Phillips, Terrance D.

    1993-01-01

    A glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes.

  14. Electric heater for nuclear fuel rod simulators

    DOE Patents [OSTI]

    McCulloch, Reginald W.; Morgan, Jr., Chester S.; Dial, Ralph E.

    1982-01-01

    The present invention is directed to an electric cartridge-type heater for use as a simulator for a nuclear fuel pin in reactor studies. The heater comprises an elongated cylindrical housing containing a longitudinally extending helically wound heating element with the heating element radially inwardly separated from the housing. Crushed cold-pressed preforms of boron nitride electrically insulate the heating element from the housing while providing good thermal conductivity. Crushed cold-pressed preforms of magnesia or a magnesia-15 percent boron nitride mixture are disposed in the cavity of the helical heating element. The coefficient of thermal expansion of the magnesia or the magnesia-boron nitride mixture is higher than that of the boron nitride disposed about the heating element for urging the boron nitride radially outwardly against the housing during elevated temperatures to assure adequate thermal contact between the housing and the boron nitride.

  15. Cryostat including heater to heat a target

    DOE Patents [OSTI]

    Pehl, Richard H.; Madden, Norman W.; Malone, Donald F.

    1990-01-01

    A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vesssel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism.

  16. Cryostat including heater to heat a target

    DOE Patents [OSTI]

    Pehl, R.H.; Madden, N.W.; Malone, D.F.

    1990-09-11

    A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vessel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism. 2 figs.

  17. Tubular electric heater with a thermocouple assembly

    DOE Patents [OSTI]

    House, R.K.; Williams, D.E.

    1975-08-01

    This patent relates to a thermocouple or other instrumentation which is installed within the walls of a tubular sheath surrounding a process device such as an electric heater. The sheath comprises two concentric tubes, one or both of which have a longitudinal, concave crease facing the other tube. The thermocouple is fixedly positioned within the crease and the outer tube is mechanically reduced to form an interference fit onto the inner tube. (auth)

  18. Fired heater for coal liquefaction process

    DOE Patents [OSTI]

    Ying, David H. S.; McDermott, Wayne T.; Givens, Edwin N.

    1985-01-01

    A fired heater for a coal liquefaction process is operated under conditions to maximize the slurry slug frequency and thereby improve the heat transfer efficiency. The operating conditions controlled are (1) the pipe diameter and pipe arrangement, (2) the minimum coal/solvent slurry velocity, (3) the maximum gas superficial velocity, and (4) the range of the volumetric flow velocity ratio of gas to coal/solvent slurry.

  19. Analysisi Benchmark of the Single Heater Test

    SciTech Connect (OSTI)

    H.M. Wade; H. Marr; M.J. Anderson

    2006-07-27

    The Single Heater Test (SHT) is the first of three in-situ thermal tests included in the site characterization program for the potential nuclear waste monitored geologic repository at Yucca Mountain. The heating phase of the SHT started in August 1996 and was concluded in May 1997 after 9 months of heating. Cooling continued until January 1998, at which time post-test characterization of the test block commenced. Numerous thermal, hydrological, mechanical, and chemical sensors monitored the coupled processes in the unsaturated fractured rock mass around the heater (CRWMS M&O 1999). The objective of this calculation is to benchmark a numerical simulation of the rock mass thermal behavior against the extensive data set that is available from the thermal test. The scope is limited to three-dimensional (3-D) numerical simulations of the computational domain of the Single Heater Test and surrounding rock mass. This calculation supports the waste package thermal design methodology, and is developed by Waste Package Department (WPD) under Office of Civilian Radioactive Waste Management (OCRWM) procedure AP-3.12Q, Revision 0, ICN 3, BSCN 1, Calculations.

  20. Columbia Water & Light- Solar Energy Loans

    Broader source: Energy.gov [DOE]

    Columbia Water & Light (CWL) offers electric residential and commercial customers low-interest loans for photovoltaic (PV) systems and solar water heaters.

  1. Solar Water Heating System Maintenance and Repair | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating System Maintenance and Repair Solar Water Heating System Maintenance and Repair Rooftop solar water heaters need regular maintenance to operate at peak efficiency. |...

  2. Solar Water Heating System Maintenance and Repair | Department...

    Energy Savers [EERE]

    Water Heating System Maintenance and Repair Solar Water Heating System Maintenance and Repair Rooftop solar water heaters need regular maintenance to operate at peak efficiency. | ...

  3. Enhanced heat transfer tubes for film absorbers of absorption chiller/heater

    SciTech Connect (OSTI)

    Sasaki, Naoe; Nosetani, Tadashi; Furukawa, Masahiro; Kaneko, Toshiyuki

    1995-12-31

    Absorption chiller/heaters using non-CFC refrigerants are attracting attention as environmentally friendly energy systems. As the refrigerant/absorbent pair, the water/lithium bromide aqueous solution pair is preferably used for most absorption chiller/heaters in Japan. Absorption chiller/heaters, mainly used as water chillers and air-conditioners, are commercially available at least for unit cooling capacities above 60 kW. In absorption chiller/heaters, the absorber must be made compact, because the absorber has the largest heat transfer area of the four primary heat exchangers in the system: the evaporator, absorber, regenerator and condenser. Although a great amount of information is available on the evaporator and condenser, the same type of information concerning the absorber is lacking. This paper introduces two kinds of double fluted tubes called Arm tubs and Floral tubes for film absorbers. Arm tubes are manufactured using a two-pass drawbench process, while Floral tubes are made using a single pass drawbench process. The experiments using a lithium bromide aqueous solution with the addition of 250 ppm n-octyl alcohol as the surfactant showed that Arm tubes and Floral tubes had about 40% higher heat transfer performance than plain tubes. Therefore, Floral tubes are expected to realize a high performance at low cost. Furthermore, the optimization of the number of grooves on the outside of the tubes is also described here.

  4. NREL: Wind Research - Wind and Water Power Fact Sheets

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Wind and Water Power Fact Sheets The capabilities for research at the National Wind Technology Center (NWTC) are numerous. Below you will find fact sheets about the many facilities and capabilities at the NWTC, including field testing research, modeling and simulation, and the Wind-Wildlife Impacts Literature Database. Fact Sheet Cover 35 Years of Innovation: Leading the Way to a Clean Energy Future Fact Sheet Cover Wind-Wildlife Impacts Literature Database (WILD) Fact Sheet Cover NREL Software

  5. NREL: Water Power Research - Design Review and Analysis

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Design Review and Analysis NREL is leveraging its 35 years of experience in renewable energy technologies to accelerate the development of robust and efficient water power devices and components. As part of this effort, NREL researchers provide industry partners with design reviews and analyses. In addition to design reviews, NREL offers technical assistance to solve specific technical problems and conducts parallel research to provide a foundation for the increasingly complex engineering

  6. Automated robotic equipment for ultrasonic inspection of pressurizer heater wells

    DOE Patents [OSTI]

    Nachbar, Henry D.; DeRossi, Raymond S.; Mullins, Lawrence E.

    1993-01-01

    A robotic device for remotely inspecting pressurizer heater wells is provided which has the advantages of quickly, precisely, and reliably acquiring data at reasonable cost while also reducing radiation exposure of an operator. The device comprises a prober assembly including a probe which enters a heater well, gathers data regarding the condition of the heater well and transmits a signal carrying that data; a mounting device for mounting the probe assembly at the opening of the heater well so that the probe can enter the heater well; a first motor mounted on the mounting device for providing movement of the probe assembly in an axial direction; and a second motor mounted on the mounting device for providing rotation of the probe assembly. This arrangement enables full inspection of the heater well to be carried out.

  7. Sustainable Energy Resources for Consumers Webinar on Residential Water

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heaters | Department of Energy Water Heaters Sustainable Energy Resources for Consumers Webinar on Residential Water Heaters 20110222_webinar_transcript.pdf (117.27 KB) More Documents & Publications Overcoming Persistent Barriers to Energy Efficiency in Multifamily Housing through Partnerships overcoming_persistent_barriers_energy_efficiency_multifamily_housing.doc Recording of SERC Monitoring Technologies - Solar Photovoltaics

  8. DOE-Funded Research Wins 26 Awards | U.S. DOE Office of Science...

    Office of Science (SC) Website

    extreme wear and abrasion resistance; a heat pump water heater that uses one-third the electricity of a conventional water heater; a way to recharge lead-acid batteries that ...

  9. Multi-step heater deployment in a subsurface formation

    DOE Patents [OSTI]

    Mason, Stanley Leroy

    2012-04-03

    A method for installing a horizontal or inclined subsurface heater includes placing a heating section of a heater in a horizontal or inclined section of a wellbore with an installation tool. The tool is uncoupled from the heating section. A lead in section is mechanically and electrically coupled to the heating section of the heater. The lead-in section is located in an angled or vertical section of the wellbore.

  10. Hot Topics Summer Workshops | Photosynthetic Antenna Research Center

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Hot Showers, Fresh Laundry, Clean Dishes Hot Showers, Fresh Laundry, Clean Dishes March 5, 2013 - 11:17am Addthis The GE GeoSpring™ Electric Heat Pump Water Heater is readily integrated into new and existing home designs. Taking up the same footprint as a traditional 50-gallon tank water heater, the Electric Heat Pump Water Heater uses the existing water heater's plumbing and electrical connections. Credit: GE The GE GeoSpring(tm) Electric Heat Pump Water Heater is readily integrated into

  11. Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration

    DOE Patents [OSTI]

    Vinegar, Harold J.; Sandberg, Chester Ledlie

    2010-11-09

    A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

  12. 01-05-1998 - Heater Malfunction | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Heater Malfunction Document Number: NA Effective Date: 01/1998 File (public): PDF icon 01-05-1998_yellow_alert

  13. Stainless Steel Hotplate Heater for Long Objects --- Inventor...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Stainless Steel Hotplate Heater for Long Objects --- Inventor(s): Stephan Jurczynski and ... High electrical current is passed through a stainless steel plate longer and slightly ...

  14. Slurry fired heater cold-flow modelling

    SciTech Connect (OSTI)

    Moujaes, S.F.

    1983-07-01

    This report summarizes the experimental and theoretical work leading to the scale-up of the SRC-I Demonstration Plant slurry fired heater. The scale-up involved a theoretical model using empirical relations in the derivation, and employed variables such as flow conditions, liquid viscosity, and slug frequency. Such variables have been shown to affect the heat transfer characteristics ofthe system. The model assumes that, if all other variables remain constant, the heat transfer coefficient can be scaled up proportional to D/sup -2/3/ (D = inside diameter of the fired heater tube). All flow conditions, liquid viscosities, and pipe inclinations relevant to the demonstration plant have indicated a slug flow regime in the slurry fired heater. The annular and stratified flow regimes should be avoided to minimize the potential for excessive pipe erosion and to decrease temperature gradients along the pipe cross section leading to coking and thermal stresses, respectively. Cold-flow studies in 3- and 6.75-in.-inside-diameter (ID) pipes were conducted to determine the effect of scale-up on flow regime, slug frequency, and slug dimensions. The developed model assumes that conduction heat transfer occurs through the liquid film surrounding the gas slug and laminar convective heat transfer to the liquid slug. A weighted average of these two heat transfer mechanisms gives a value for the average pipe heat transfer coefficient. The cold-flow work showed a decrease in the observed slug frequency between the 3- and 6.75-ID pipes. Data on the ratio of gas to liquid slug length in the 6.75-in. pipe are not yet complete, but are expected to yield generally lower values than those obtained in the 3-in. pipe; this will probably affect the scale-up to demonstration plant conditions. 5 references, 15 figures, 7 tables.

  15. Shipping device for heater unit assembly

    DOE Patents [OSTI]

    Blaushild, Ronald M.; Abbott, Stephan L.; Miller, Phillip E.; Shaffer, Robert

    1991-01-01

    A shipping device for a heater unit assembly (23), the heater unit assembly (23) including a cylindrical wall (25) and a top plate (31) secured to the cylindrical wall (25) and having a flange portion which projects radially beyond the outer surface of the cylindrical wall (25), and the shipping device including: a cylindrical container (3) having a closed bottom (13); a support member (47) secured to the container (3) and having an inwardly directed flange for supporting the flange portion of the top plate (31); a supplemental supporting system (1) for positioning the heater unit assembly (23) in the container (3) at a spaced relation from the inner surface and bottom wall (13) of the container (3); a cover (15) for closing the top of the container (3); and a container supporting structure (5,7,8) supporting the container (3) in a manner to permit the container (3) to be moved, relative to the supporting structure (5,7,8 ), between a vertical position for loading and unloading the assembly (23) and a horizontal position for transport of the assembly (23). A seal (57) is interposed between the container (3) and the cover (15) for sealing the interior of the container (3) from the environment. An abutment member (41) is mounted on the container supporting structure (5,7,8) for supporting the container bottom (13), when the container (3) is in the vertical position, to prevent the container (3) from moving past the vertical position in the direction away from the horizontal position, and a retainer member (55) is secured within the cover (15) for retaining the assembly top plate (31) in contact with the support member (47) when the cover (15) closes the top of the container (3).

  16. Probe with integrated heater and thermocouple pack

    DOE Patents [OSTI]

    McCulloch, Reg W.; Dial, Ralph E.; Finnell, Wilber K. R.

    1990-01-01

    A probe for measuring heat includes an elongate rod fitted within a sheath, and a plurality of annular recesses are formed on the surface of the rod in a spaced-apart relationship to form annular chambers that are resistant to heat flow. A longitudinal bore extends axially into the rod and within the cylinders defined by the annular chambers, and an integrated heater and thermocouple pack is dimensioned to fit within the bore. In construction, the integrated pack includes a plurality of wires disposed in electrical insulation within a sheath and a heater cable. These wires include one common wire and a plurality of thermocuple wires. The common wire is constructed of one type of conductive material while the thermocouple wires are each constructed of two types of materials so that at least one thermocouple junction is formed therein. All of the wires extend the length of the integrated pack and are connected together at their ends. The thermocouple wires are constructed to form thermocouple junctions proximate to each annular chamber for producing electromotive forces corresponding to the temperature of the rod within the annular chambers relative to outside the chambers. In the preferred embodiment, each thermocouple wire forms two thermocouple junctions, one junction being disposed within an annular chamber and the second junction being disposed outside of, but proximate to, the same annular chamber. In one embodiment two thermocouple wires are configured to double the sensitivity of the probe in one region.

  17. Probe with integrated heater and thermocouple pack

    DOE Patents [OSTI]

    McCulloch, Reginald W. (Oak Ridge, TN); Dial, Ralph E. (Concord, TN); Finnell, Wilber K. R. (Kingston, TN)

    1988-01-01

    A probe for measuring heat includes an elongate rod fitted within a sheath, and a plurality of annular recesses are formed on the surface of the rod in a spaced-apart relationship to form annular chambers that are resistant to heat flow. A longitudinal bore extends axially into the rod and within the cylinders defined by the annular chambers, and an integrated heater and thermocouple pack is dimensioned to fit within the bore. In construction, the integrated pack includes a plurality of wires disposed in electrical insulation within a sheath and a heater cable. These wires include one common wire and a plurality of thermocouple wires. The common wire is constructed of one type of conductive material while the thermocouple wires are each constructed of two types of materials so that at least one thermocouple junction is formed therein. All of the wires extend the length of the integrated pack and are connected together at their ends. The thermocouple wires are constructed to form thermocouple junctions proximate to each annular chamber for producing electromotive forces corresponding to the temperature of the rod within the annular chambers relative to outside the chambers. In the preferred embodiment, each thermocouple wire forms two thermocouple junctions, one junction being disposed within an annular chamber and the second junction being disposed outside of, but proximate to, the same annular chamber. In one embodiment two thermocouple wires are configured to double the sensitivity of the probe in one region.

  18. Water Infrastructure Security

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water Heating Products and Services Water Heating Products and Services Choosing an efficient water heater will help you save money and Energy. | Photo Credit Energy Department Choosing an efficient water heater will help you save money and Energy. | Photo Credit Energy Department Use the following links to get product information and locate professional services for water heating. Product Information Solar Pool Heating Systems Florida Solar Energy Center Listing of solar pool heating systems

  19. Tips: Water Heating | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating Tips: Water Heating Keep your energy bills out of hot water. Insulate your water heater to save ... Drain-water, or greywater, heat recovery systems capture the energy ...

  20. Pollutant emissions from portable kerosene-fired space heaters

    SciTech Connect (OSTI)

    Traynor, G.W.; Allen, J.R.; Apte, M.G.; Girman, J.R.; Hollowell, C.D.

    1983-06-01

    Indoor use of unvented combustion appliances is known to cause an increase in indoor air pollutants. We conducted laboratory tests on two radiant and two convective portable kerosene-fired space heaters to identify the pollutants they emit and to determine their emission rates. Results show that carbon dioxide, carbon monoxide, nitric oxide, nitrogen dioxide, and formaldehyde were emitted by both types of heaters and that the radiant heaters and one of the convective heaters also emitted trace amounts of fine particles. When such heaters are operated for 1 h in a 27-m/sup 3/ chamber with 0.4 air changes per hour, the resultant CO/sub 2/ concentrations are well above the U.S. occupational standard, and NO/sub 2/ concentrations are well above California's short-term outdoor standard.

  1. ISSUANCE 2015-10-15: Energy Conservation Standards for Pool Heaters...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Standards for Pool Heaters, Notice of Data Availability ISSUANCE 2015-10-15: Energy Conservation Standards for Pool Heaters, Notice of Data Availability This document is the Energy ...

  2. Purchasing Energy-Efficient Residential Whole-Home Gas Tankless Water

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heaters | Department of Energy Whole-Home Gas Tankless Water Heaters Purchasing Energy-Efficient Residential Whole-Home Gas Tankless Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for residential whole-home gas tankless water heaters, a product category covered by ENERGY STAR efficiency requirements. Federal laws and requirements mandate that agencies purchase ENERGY STAR-qualified products or FEMP-designated products in all product categories

  3. Vera Water & Power- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Vera Water and Power offers several rebates to electric customers who purchase and install energy efficient equipment. Rebates are available for water heaters, windows, heat pumps, clothes washer,...

  4. Laboratory Evaluation of Gas-Fired Tankless and Storage Water...

    Office of Scientific and Technical Information (OSTI)

    Technical Report: Laboratory Evaluation of Gas-Fired Tankless and Storage Water Heater Approaches to Combination Water and Space Heating Citation Details In-Document Search Title: ...

  5. Grid-Interactive Renewable Water Heating Economic and Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    1 Grid-Interactive Renewable Water Heating Economic and Environmental Value Grid-interactive renewable water heaters have smart controls that quickly change their charge rate and ...

  6. DOE Science Showcase - Heat Pump Research | OSTI, US Dept of...

    Office of Scientific and Technical Information (OSTI)

    HEATING PERFORMANCE GEOTHERMAL HEATING WATER SOURCE HEAT PUMPS EVALUATION DOCUMENT ... Geothermal Heat Pumps - Heating Mode Cooling Mode Animations Heat Pump Water Heaters ...

  7. Summary of AEP`s experience with retubing feedwater heaters

    SciTech Connect (OSTI)

    Cashner, B.

    1995-12-01

    American Electric Power (AEP) oversees the design, operation and maintenance of 500+ low pressure (LP) and high pressure (HP) feedwater heaters on subcritical and supercritical pressure fossil generating units. Approximately 150 of these U-tubed heaters have been successfully retubed since the 1970`s, with a majority of the retubings performed in the field by qualified heat exchanger companies. Due to the large number of retubed heaters, AEP has gone through the {open_quotes}learning curve{close_quotes} and refined its technical specifications for retubing heaters. In comparison to the 150 retubed heaters, over 70 LP and HP heaters have been replaced. Examples will be presented comparing the engineering and cost benefits for retubing versus replacement. A total of 24 bar charts are attached which summarize operating experience with the original heater tube materials and replacement tube materials. The tube materials consist of arsenical copper, copper-nickels, admiralty, monel, carbon steel and stainless steels. A brief discussion of AEP`s recommended tube materials for various applications will be presented, taking into account long term operation and heat rate impacts.

  8. Field Demonstration of High Efficiency Gas Heaters | Department...

    Broader source: Energy.gov (indexed) [DOE]

    This report discusses a field demonstration to analyze the energy savings for one of these ... Louis, MO. Field Demonstration of High Efficiency Gas Heaters (2.28 MB) More Documents & ...

  9. Property:Building/SPElectrtyUsePercElctrcEngineHeaters | Open...

    Open Energy Info (EERE)

    rcElctrcEngineHeaters" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 0.0 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 0.0...

  10. Light-weight radioisotope heater impact tests

    SciTech Connect (OSTI)

    Reimus, M.A.H.; Rinehart, G.H.; Herrera, A.

    1998-12-31

    The light-weight radioisotope heater unit (LWRHU) is a {sup 238}PuO{sub 2}-fueled heat source designed to provide one thermal watt in each of various locations on a spacecraft. Los Alamos National Laboratory designed, fabricated, and safety tested the LWRHU. The heat source consists of a hot-pressed {sup 238}PuO{sub 2} fuel pellet, a Pt-30Rh vented capsule, a pyrolytic graphite insulator, and a fineweave-pierced fabric graphite aeroshell assembly. To compare the performance of the LWRHUs fabricated for the Cassini mission with the performance of those fabricated for the Galileo mission, and to determine a failure threshold, two types of impact tests were conducted. A post-reentry impact test was performed on one of 180 flight-quality units produced for the Cassini mission and a series of sequential impact tests using simulant-fueled LWRHU capsules were conducted respectively. The results showed that deformation and fuel containment of the impacted Cassini LWRHU was similar to that of a previously tested Galileo LWRHU. Both units sustained minimal deformation of the aeroshell and fueled capsule; the fuel was entirely contained by the platinum capsule. Sequential impacting, in both end-on and side-on orientations, resulted in increased damage with each subsequent impact. Sequential impacting of the LWRHU appears to result in slightly greater damage than a single impact at the final impact velocity of 50 m/s.

  11. Air-pollutant emissions from kerosene space heaters

    SciTech Connect (OSTI)

    Leaderer, B.P.

    1982-12-10

    Air pollutant emissions from portable convective and radiant kerosene space heaters were measured in an environmental chamber. Emission factors for nitrogen oxides, sulfur dioxide, carbon monoxide, carbon dioxide, and oxygen depletion are presented. The data suggest that the use of such heaters in residences can result in exposures to air pollutants in excess of ambient air quality standards and in some cases in excess of occupational health standards.

  12. Kerosene vs. electric portable heaters: the question of risk

    SciTech Connect (OSTI)

    Leff, H.S.

    1984-03-01

    As home heating costs have risen, more and more people have turned to portable electric and kerosene space heaters. Kerosene heaters are cheaper to run than electric, but there are numerous health and safety issues - many of them unanswered - associated with their use. Among the issues discussed are indoor air pollution by sulfur dioxide, the life-cycle costs, the deposition of pollution on furniture, and the fire hazards.

  13. Temperature limited heater utilizing non-ferromagnetic conductor

    DOE Patents [OSTI]

    Vinegar; Harold J. , Harris; Christopher Kelvin

    2012-07-17

    A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

  14. Hydrogen production from water: Recent advances in photosynthesis research

    SciTech Connect (OSTI)

    Greenbaum, E.; Lee, J.W.

    1997-12-31

    The great potential of hydrogen production by microalgal water splitting is predicated on quantitative measurement of the algae`s hydrogen-producing capability, which is based on the following: (1) the photosynthetic unit size of hydrogen production; (2) the turnover time of photosynthetic hydrogen production; (3) thermodynamic efficiencies of conversion of light energy into the Gibbs free energy of molecular hydrogen; (4) photosynthetic hydrogen production from sea water using marine algae; (5) the potential for research advances using modern methods of molecular biology and genetic engineering to maximize hydrogen production. ORNL has shown that sustained simultaneous photoevolution of molecular hydrogen and oxygen can be performed with mutants of the green alga Chlamydomonas reinhardtii that lack a detectable level of the Photosystem I light reaction. This result is surprising in view of the standard two-light reaction model of photosynthesis and has interesting scientific and technological implications. This ORNL discovery also has potentially important implications for maximum thermodynamic conversion efficiency of light energy into chemical energy by green plant photosynthesis. Hydrogen production performed by a single light reaction, as opposed to two, implies a doubling of the theoretically maximum thermodynamic conversion efficiency from {approx}10% to {approx}20%.

  15. U.S. Department of Energy Implements Criteria for ENERGY STAR® Water

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heaters | Department of Energy Criteria for ENERGY STAR® Water Heaters U.S. Department of Energy Implements Criteria for ENERGY STAR® Water Heaters April 1, 2008 - 2:48pm Addthis WASHINGTON, DC - The U.S. Department of Energy (DOE) today announced new ENERGY STAR® criteria for water heaters, the first in the history of the program. According to DOE projections, by the end of the fifth year in effect, the new water heater criteria are expected to save Americans approximately $780 million

  16. NREL: Water Power Research - Computer-Aided Engineering Tools

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Engineering Tools Computer simulation of a floating point absorber in water. The water is represented by blue and red stripes. The absorber is represented by a red disk above water ...

  17. Research and Development Roadmap for Emerging Water Heating Technologi...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Emerging Water Heating Technologies W. Goetzler, M. Guernsey, and M. Droesch September ... AND DEVELOPMENT ROADMAP FOR EMERGING WATER HEATING TECHNOLOGIES ii Preface Preface ...

  18. NREL: Water Power Research - Device and Component Testing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    NREL houses the nation's premier laboratory facilities for testing offshore wind and water ... to obtain high-resolution measurements in the laboratory and open water test sites. ...

  19. Heat Transfer Fluids for Solar Water Heating Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Solar Water Heaters » Heat Transfer Fluids for Solar Water Heating Systems Heat Transfer Fluids for Solar Water Heating Systems Illustration of a solar water heater. Illustration of a solar water heater. Heat-transfer fluids carry heat through solar collectors and a heat exchanger to the heat storage tanks in solar water heating systems. When selecting a heat-transfer fluid, you and your solar heating contractor should consider the following criteria: Coefficient of expansion - the fractional

  20. Central Multifamily Water Heating Systems

    Broader source: Energy.gov [DOE]

    The Building America Program is hosting a no-cost, webinar-based training on Central Multifamily Water Heating Systems. The webinar will focus the effective use of central heat pump water heaters...

  1. Columbia Water & Light- Solar Rebates

    Broader source: Energy.gov [DOE]

    Columbia Water & Light electric customers are eligible for a $400 rebate for the purchase of a new solar water heater. To apply for this rebate, a customer submits a pre-approval application to...

  2. Using Solar Hot Water to Address Piping Heat Losses in Multifamily...

    Office of Scientific and Technical Information (OSTI)

    Subject: residential; Residential Buildings; ARBI; Building America; TRNSYS; multifamily; domestic hot water; solar water heater; recirculation Word Cloud More Like This Full Text ...

  3. Solar Swimming Pool Heaters | Department of Energy

    Energy Savers [EERE]

    A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- ...

  4. NREL: Water Power Research - Computer-Aided Engineering

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    simulation that illustrates the flow patterns of water, represented by red circles and dots, around several two-bladed current turbines that appear to e floating in blue water. ...

  5. Water Treatment in Oil and Gas Production | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Water Treatment and Reuse in Unconventional Gas Production Click to email this to a friend ... Water Treatment and Reuse in Unconventional Gas Production A key challenge in tapping vast ...

  6. Current Research Portfolio

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    in a storage tank. In the US market today, heat pump water heaters are of the integral type and typically use R-410a. In the near future, at least one manufacturer intends to...

  7. NREL: Buildings Research - Publications

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... NREL Provides Guidance to Improve Air Mixing and Thermal ... FS-5500-54845. Solar Water Heater Roadmap Leads Path to Market ... Evaluation of Humidity Control Options in Hot-Humid ...

  8. Water-Heating Dehumidifier - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Find More Like This Return to Search Water-Heating Dehumidifier Oak Ridge National ... developed at ORNL dehumidifies air and then recycles heat to warm water in a water heater. ...

  9. Evaluation of a jet plate solar air heater

    SciTech Connect (OSTI)

    Choudhury, C.; Garg, H.P. )

    1991-01-01

    To achieve higher heat transfer from the absorber plate to the flowing air stream with an intention to increase the amount of the collected energy, and hence, to improve the efficiency of an air-based solar collector, a unique jet impingement concept has been advanced for evaluation in the present study. To investigate the effects of various geometrical parameters such as the hole or nozzle diameter on the jet plate, their interspacings, the nozzle height, the distance between the absorber and the jet plate and the operational parameter such as the velocity of air impinging out of the holes/nozzles on to the back side of the absorber surface on the performance parameters of the jet impingement concept air heater, a detailed theoretical parametric analysis has been made on the design for different mass flow rates of air and different lengths of air channel. A parallel study has also been carried out on a conventional parallel plate air heater in order to compare its air temperature increment and performance efficiency with those of the jet plate air heater. The gain in air temperature increment and performance efficiency of the jet-concept air heater over that of the parallel plate air heater with duct depth 10 cm and length 2 m is 15.5{degree}C to 2.5{degree}C and 26.5% to 19%, respectively, for air flow rates in the range 50 to 250 kg/hm{sup 2}.

  10. New Residential Water Heater Concept Promises High Efficiency, Lower Cost |

    Energy Savers [EERE]

    Students Plan Solar Energy Project New Mexico Students Plan Solar Energy Project July 14, 2010 - 5:07pm Addthis Stephen Graff Former Writer & editor for Energy Empowers, EERE What are the key facts? New Mexico received $4.5 million through State Energy Program Recovery Act Grant Los Lunas High School received $300,000 to build solar energy system Renewable energy to save school $20,000 a year Engineering students at Los Lunas High School in New Mexico put their knowledge to work by scoping

  11. Heat Pump Water Heater Modeling in EnergyPlus (Presentation)

    SciTech Connect (OSTI)

    Wilson, E.; Christensen, C.

    2012-03-01

    This presentation summarizes NREL's development of a HPWH model for use in hourly building energy simulation programs, such as BEopt; this presentation was given at the Building America Stakeholder meeting on March 1, 2012, in Austin, Texas.

  12. EERE Success Story-Xergy Develops Breakthrough Water Heater Compressor...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... of magnitude improvement over Peltierthermoelectric systems 1 Quad in potential annual ... systems, electronics and battery cooling, automotive systems Recognition 2011 GE ...

  13. Coweta-Fayette EMC- Residential Solar Water Heater Rebate Program

    Broader source: Energy.gov [DOE]

    Coweta-Fayette Electric Membership Corporation (EMC) provides electric and natural gas service to 58,000 customers in Georgia's Coweta, Fayette, Meriwether, Heard, Troop and Fulton counties.

  14. New Braunfels Utilities- Residential Solar Water Heater Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Funding is limited and is awarded on a first-come, first-served basis. Applications are located on the program web site.

  15. Tankless or Demand-Type Water Heaters | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Do the following when selecting a contractor: Request cost estimates in writing Ask for references Check the company with your local Better Business Bureau See if the company will ...

  16. Ocala Utility Services- Solar Hot Water Heating Rebate Program

    Broader source: Energy.gov [DOE]

    The Solar Water Heater Rebate Program is offered to residential retail electric customers by the City of Ocala Utility Services. Interested customers must complete an application and receive...

  17. Sacramento Ordinance to Waive Fees for Solar Hot Water

    Broader source: Energy.gov [DOE]

    An ordinance suspending for the calendar years 2007-2009 all fees related to installations of solar water heaters on existing residences.

  18. Consolidated Electric Cooperative- Heat Pump and Water Heating Rebates

    Office of Energy Efficiency and Renewable Energy (EERE)

    Consolidated Electric Cooperative provides rebates to residential customers who install electric water heaters, dual-fuel heating system or geothermal heat pumps. A dual-fuel heating systems...

  19. City Water Light and Power - Residential Energy Efficiency Rebate...

    Broader source: Energy.gov (indexed) [DOE]

    Clothes Washers Water Heaters Heat Pumps Building Insulation Maximum Rebate Building Insulation: 500 Program Info Sector Name Utility Administrator Energy Services Office Website...

  20. Kerosene space heaters--combustion technology and kerosene characteristics

    SciTech Connect (OSTI)

    Kubayashi, k.; I Wasaki, N.

    1984-07-01

    This paper describes kerosene combustion technology. Unvented wick-type kerosene space heaters are very popular in Japan because of their economy and convenience. In recent years new vaporized kerosene burners having premixed combustion systems have been developed to solve some of the problems encountered in the older portable type. Some of the features of the new burners are instantaneous ignition, no vaporizing deposit on the burner and a wide range heating capacity. These new kerosene heaters have four major components: an air supply fan, a fuel supply assembly, a burner assembly and a control assembly. These heaters are designed to be highly reliable, have stable combustion characteristics, yield minimum carbon deposit. Finally, they are simple and inexpensive to operate.

  1. Feedback regulated induction heater for a flowing fluid

    DOE Patents [OSTI]

    Migliori, A.; Swift, G.W.

    1984-06-13

    A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable porportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005/sup 0/C at a flow rate of 50 cm/sup 3//sec with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

  2. Feedback regulated induction heater for a flowing fluid

    DOE Patents [OSTI]

    Migliori, Albert; Swift, Gregory W.

    1985-01-01

    A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable proportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005.degree. C. at a flow rate of 50 cm.sup.3 /second with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

  3. Low-Temperature Gasoline Combustion (LTGC) Engine Research

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Sandia LTGC Engine Laboratory All-Metal Engine Optical Engine Optics Table Dynamometer Intake Plenum Exhaust Plenum Water & Oil Pumps & Heaters Flame Arrestor Matching ...

  4. NREL: Water Power Research - Economic and Power System Modeling...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    The model represents the initial capital investment of offshore projects, considering project size, water depth, distance from shore, and turbine technology. NREL also develops ...

  5. Treating and Reusing Produced Water | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Oklahoma City, are working to develop new cost-effective and sustainable methods for ... Advanced technologies in both water treatment and well drilling exist today that will make ...

  6. Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff...

    Energy Savers [EERE]

    Space Heater Space Heater (low end of energy use): (750 W x 8 hours) 1000 6 kWhday (daily consumption) 6 kWhday x ... have no additional electricity costs, and you won't ...

  7. How Do You Use a Space Heater Efficiently? | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    explored the question of space heaters and found that there are many factors to consider when deciding whether to use a space heater or central heating system. How do you use a...

  8. ISSUANCE 2015-10-15: Energy Conservation Standards for Pool Heaters, Notice

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Data Availability | Department of Energy Standards for Pool Heaters, Notice of Data Availability ISSUANCE 2015-10-15: Energy Conservation Standards for Pool Heaters, Notice of Data Availability This document is the Energy Conservation Standards for Pool Heaters, Notice of Data Availability. Electric_Pool_Heaters_NODA.pdf (210.63 KB) More Documents & Publications Energy Conservation Program for Consumer Products: Energy Conservation Standards for Direct Heating Equipment and Pool

  9. Secretary Chu Announces More Stringent Appliance Standards for Home Water

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Heaters and Other Heating Products | Department of Energy Stringent Appliance Standards for Home Water Heaters and Other Heating Products Secretary Chu Announces More Stringent Appliance Standards for Home Water Heaters and Other Heating Products April 1, 2010 - 12:00am Addthis WASHINGTON - U.S. Department of Energy Secretary Steven Chu announced today that the Department has finalized higher energy efficiency standards for a key group of heating appliances that will together save consumers

  10. Water augmented indirectly-fired gas turbine systems and method

    DOE Patents [OSTI]

    Bechtel, Thomas F.; Parsons, Jr., Edward J.

    1992-01-01

    An indirectly-fired gas turbine system utilizing water augmentation for increasing the net efficiency and power output of the system is described. Water injected into the compressor discharge stream evaporatively cools the air to provide a higher driving temperature difference across a high temperature air heater which is used to indirectly heat the water-containing air to a turbine inlet temperature of greater than about 1,000.degree. C. By providing a lower air heater hot side outlet temperature, heat rejection in the air heater is reduced to increase the heat recovery in the air heater and thereby increase the overall cycle efficiency.

  11. Design and performance of low-wattage electrical heater probe

    SciTech Connect (OSTI)

    Biddle, R.; Wetzel, J.R.; Cech, R.

    1997-11-01

    A mound electrical calibration heater (MECH) has been used in several EG and G Mound developed calorimeters as a calibration tool. They are very useful over the wattage range of a few to 500 W. At the lower end of the range, a bias develops between the MECH probe and calibrated heat standards. A low-wattage electrical calibration heater (L WECH) probe is being developed by the Safeguards Science and Technology group (NIS-5) of Los Alamos National Laboratory based upon a concept proposed by EG and G Mound personnel. The probe combines electrical resistive heating and laser-light powered heating. The LWECH probe is being developed for use with power settings up to 2W. The electrical heater will be used at the high end of the range, and laser-light power will be used low end of the wattage range. The system consists of two components: the heater probe and a control unit. The probe is inserted into the measuring cavity through an opening in the insulating baffle, and a sleeve is required to adapt to the measuring chamber. The probe is powered and controlled using electronics modules located separately. This paper will report on the design of the LWECH probe, initial tests, and expected performance.

  12. 2012 WATER & AQUEOUS SOLUTIONS GORDON RESEARCH CONFERENCE (GRC) AND GORDON RESEARCH SEMINAR (GRS), AUG 10-17, 2012

    SciTech Connect (OSTI)

    Dor Ben-Amotz, PI

    2012-08-17

    Understanding the fundamental principles governing the structure and dynamics of water - and particularly how water mediates chemical interactions and processes - continues to pose formidable challenges and yield abundant surprises. The focus of this Gordon Research Conference is on identifying key questions, describing emerging understandings, and unveiling surprising discoveries related to water and aqueous solutions. The talks and posters at this meeting will describe studies of water and its interactions with objects such as interfaces, channels, electrons, oils, ions, and proteins; probed using optical, electrical, and particle experiments, and described using classical, quantum, and multi-scale theories.

  13. Three-phase heaters with common overburden sections for heating subsurface formations

    DOE Patents [OSTI]

    Vinegar, Harold J. (Bellaire, TX)

    2012-02-14

    A heating system for a subsurface formation is described. The heating system includes three substantially u-shaped heaters with first end portions of the heaters being electrically coupled to a single, three-phase wye transformer and second end portions of the heaters being electrically coupled to each other and/or to ground. The three heaters may enter the formation through a first common wellbore and exit the formation through a second common wellbore so that the magnetic fields of the three heaters at least partially cancel out in the common wellbores.

  14. Save on Home Water Heating | Department of Energy

    Energy Savers [EERE]

    on Home Water Heating Save on Home Water Heating August 19, 2014 - 10:46am Addthis Purchasing a water heater with the ENERGY STAR label ensures you are buying an energy ...

  15. Water Heating Products and Services | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating Products and Services Water Heating Products and Services May 29, 2012 - 7:04pm Addthis Choosing an efficient water heater will help you save money and Energy. |...

  16. Solar Water Heating System Maintenance and Repair | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating System Maintenance and Repair Solar Water Heating System Maintenance and Repair May 30, 2012 - 2:35pm Addthis Rooftop solar water heaters need regular maintenance to...

  17. ENERGY STAR Webinar - Update: EPA's Research into a Potential 1-100 Water

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Score for Multifamily Housing | Department of Energy Webinar - Update: EPA's Research into a Potential 1-100 Water Score for Multifamily Housing ENERGY STAR Webinar - Update: EPA's Research into a Potential 1-100 Water Score for Multifamily Housing August 30, 2016 2:00PM to 3:30PM EDT Hosted by the U.S. Environmental Protection Agency's (EPA's) ENERGY STAR, this webinar will cover research and findings to date on the water use for multifamily properties. EPA will solicit your input on some

  18. Research and Development Roadmap for Emerging Water Heating Technologies

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Research & Development Roadmap for Building Energy Modeling-Draft-for Review Only C.E. Barbour, R. Zogg, E. Cross, D. Clark February 2016 Prepared by Navigant Consulting, Inc. (This page intentionally left blank) NOTICE This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government, nor any agency thereof, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any

  19. NREL: Water Power Research - Economic and Power System Modeling and

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Analysis Economic and Power System Modeling and Analysis NREL's Economic Analysis and power system modeling integrates data from device deployment and programmatic research into deployment and scenario models to quantify the economic and societal benefits of developing cost-competitive marine and hydrokinetic systems. It also identifies policy mechanisms, market designs, and supply chain needs to support various deployment scenarios, provide information and training to potential members of

  20. Chiller-heater unit nets building 2-yr payback

    SciTech Connect (OSTI)

    Duffy, J.

    1983-05-09

    A 500-ton double-absorption Hitachi Paraflow chiller-heater that switches from purchased steam to natural gas will reduce a Manhattan office building's energy costs by 55% and achieve a two-year payback. The new system replaces a steam-powered, single-stage absorption chiller. By reusing heat in a second-stage generator, the Hitachi unit uses only half as many Btus per ton as a conventional chiller. (DCK)

  1. Fossil plant cycling impacts on feedwater heaters

    SciTech Connect (OSTI)

    O`Connor, D.

    1995-12-01

    As the U.S. electric utility industry faces the most challenging period in its history, EPRI research is focused on providing products and services that help utilities meet these challenges. Currently, a dominant issue for fossil plants is the need to reduce operation and maintenance costs in order to maintain their profitability in an increasingly competitive business environment. Cycling operation can significantly effect plant O&M costs and must, therefore be done in the most effective and efficient manner. Ongoing R&D is providing new products and strategies addressing cycling operation that utilities can implement to optimize O&M costs for least-cost power production.

  2. Comparison of Advanced Residential Water Heating Technologies in the United States

    SciTech Connect (OSTI)

    Maguire, Jeff; Fang, Xia; Wilson, Eric

    2013-05-01

    In this study, gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the United States, installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many pre-existing models were used, new models of condensing and heat pump water heaters were created specifically for this work. In each case modeled, the whole house was simulated along with the water heater to capture any interactions between the water heater and the space conditioning equipment.

  3. CenterPoint Energy (Gas)- Residential Heating and Hot Water Rebates

    Office of Energy Efficiency and Renewable Energy (EERE)

    CenterPoint Energy offers gas heating and water heating equipment rebates to its residential customers. Eligible equipment includes furnaces, back-up furnace systems, hydronic heaters, storage...

  4. Materials performance in fluidized-bed air heaters

    SciTech Connect (OSTI)

    Natesan, K.; Podolski, W.

    1991-12-01

    Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

  5. Materials performance in fluidized-bed air heaters

    SciTech Connect (OSTI)

    Natesan, K.; Podolski, W.

    1991-12-01

    Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock & Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

  6. Light-water-reactor safety research program. Quarterly progress report, January-March 1980

    SciTech Connect (OSTI)

    Massey, W.E.; Kyger, J.A.

    1980-08-01

    This progress report summarizes the Argonne National Laboratory work performed during January, February, and March 1980 on water-reactor-safety problems. The research and development area covered is Transient Fuel Response and Fission-Product Release.

  7. #AskEnergySaver: Home Water Heating | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating #AskEnergySaver: Home Water Heating March 24, 2014 - 11:35am Addthis Did you know: Water heaters account for nearly 17 percent of a home’s energy use, consuming more energy than all other household appliances combined. For more about water heaters, check out our <a href="/node/612476">Energy Saver 101 home water heating infographic</a>. | Photo by Eric Grigorian, U.S. Department of Energy Solar Decathlon. Did you know: Water heaters account for nearly 17

  8. Strategic Plan for Light Water Reactor Research and Development

    SciTech Connect (OSTI)

    2004-02-01

    The purpose of this strategic plan is to establish a framework that will allow the Department of Energy (DOE) and the nuclear power industry to jointly plan the nuclear energy research and development (R&D) agenda important to achieving the Nation's energy goals. This strategic plan has been developed to focus on only those R&D areas that will benefit from a coordinated government/industry effort. Specifically, this plan focuses on safely sustaining and expanding the electricity output from currently operating nuclear power plants and expanding nuclear capacity through the deployment of new plants. By focusing on R&D that addresses the needs of both current and future nuclear plants, DOE and industry will be able to take advantage of the synergism between these two technology areas, thus improving coordination, enhancing efficiency, and further leveraging public and private sector resources. By working together under the framework of this strategic plan, DOE and the nuclear industry reinforce their joint commitment to the future use of nuclear power and the National Energy Policy's goal of expanding its use in the United States. The undersigned believe that a public-private partnership approach is the most efficient and effective way to develop and transfer new technologies to the marketplace to achieve this goal. This Strategic Plan is intended to be a living document that will be updated annually.

  9. New Research Facility to Remove Hurdles to Offshore Wind and Water Power

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Development | Department of Energy Research Facility to Remove Hurdles to Offshore Wind and Water Power Development New Research Facility to Remove Hurdles to Offshore Wind and Water Power Development January 10, 2013 - 1:59pm Addthis This is an excerpt from the Fourth Quarter 2012 edition of the Wind Program R&D Newsletter. Virginia Beach, Virginia - A new U.S. Department of Energy (DOE) research facility could help bring the United States closer to generating power from the winds and

  10. Water Heating Products and Services | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Heating Products and Services Water Heating Products and Services Choosing an efficient water heater will help you save money and Energy. | Photo Credit Energy Department Choosing an efficient water heater will help you save money and Energy. | Photo Credit Energy Department Use the following links to get product information and locate professional services for water heating. Product Information Solar Pool Heating Systems Florida Solar Energy Center Listing of solar pool heating systems

  11. Effects on carbon monoxide levels in mobile homes using unvented kerosene heaters for residential heating

    SciTech Connect (OSTI)

    Williams, R.; Walsh, D.; White, J.; Jackson, M.; Mumford, J.

    1992-01-01

    Carbon monoxide (CO) emission levels were continuously monitored in 8 mobile trailer homes less than 10 years old. These homes were monitored in an US EPA study on indoor air quality as affected by unvented portable kerosene heaters. Respondents were asked to operate their heaters in a normal fashion. CO, air exchange and temperature values were measured during the study in each home. Results indicate that consumers using unvented kerosene heaters may be unknowingly exposed to high CO levels without taking proper precautions.

  12. In the OSTI Collections: Heat Pumps | OSTI, US Dept of Energy...

    Office of Scientific and Technical Information (OSTI)

    ... types of water heaters, particularly solar water heaters. Mathematical comparison of these two types is made in the NREL report "Low-Cost Solar Water Heating Research and ...

  13. Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff Round Three

    Office of Energy Efficiency and Renewable Energy (EERE)

    #EnergyFaceoff round three goes to the electric blanket, see how much more money it can save you over a space heater!

  14. DOE Publishes Notice of Proposed Rulemaking for Direct Heating Equipment and Pool Heater Test Procedures

    Broader source: Energy.gov [DOE]

    The Department of Energy has published a notice of proposed rulemaking regarding test procedures for direct heating equipment and pool heaters.

  15. Impacts of Water Quality on Residential Water Heating Equipment

    SciTech Connect (OSTI)

    Widder, Sarah H.; Baechler, Michael C.

    2013-11-01

    Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

  16. Zoned electrical heater arranged in spaced relationship from particulate filter

    DOE Patents [OSTI]

    Gonze, Eugene V [Pinckney, MI

    2011-11-15

    A system comprises a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

  17. Integral finned heater and cooler for stirling engines

    DOE Patents [OSTI]

    Corey, John A.

    1984-01-01

    A piston and cylinder for a Stirling engine and the like having top and bottom meshing or nesting finned conical surfaces to provide large surface areas in close proximity to the working gas for good thermal (addition and subtraction of heat) exchange to the working gas and elimination of the usual heater and cooler dead volume. The piston fins at the hot end of the cylinder are perforated to permit the gas to pass into the piston interior and through a regenerator contained therein.

  18. Renewable energy technologies for federal facilities: Solar water heating

    SciTech Connect (OSTI)

    1996-05-01

    This sheet presents information on solar water heaters (passive and active), solar collectors (flat plate, evacuated tube, parabolic trough), lists opportunities for use of solar water heating, and describes what is required and the costs. Important terms are defined.

  19. Piedmont EMC- Solar Water Heating Rebate Program

    Office of Energy Efficiency and Renewable Energy (EERE)

    Piedmont Electric Membership Corporation is offering a $500 rebate to its residential members who install solar water heaters on their homes. The utility recommends but does not require the system...

  20. CPS Energy- Solar Hot Water Rebate Program

    Broader source: Energy.gov [DOE]

    As part of a larger program designed to reduce electricity demand within its service territory, CPS Energy now offers rebates for solar water heaters to its customers. In general, any CPS Energy...

  1. Los Alamos boosts light-water reactor research with advanced modeling and

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    simulation technology Los Alamos boosts light-water reactor research Los Alamos boosts light-water reactor research with advanced modeling and simulation technology As part of the consortium CASL will now be deployed to industry and academia under a new inter-institutional agreement for intellectual property. March 2, 2015 A simulation demonstrates the volume fraction of a bubble phase in the region downstream of a 3×3 rod bundle after a short burst of bubbles has been introduced into the

  2. Hot New Advances in Water Heating Technology | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Hot New Advances in Water Heating Technology Hot New Advances in Water Heating Technology April 18, 2013 - 1:15pm Addthis Learn how a cooperative R&D agreement with the Energy Department's Oak Ridge National Laboratory helped contributed to the success of GE's GeoSpring Hybrid Water Heater -- one of the most efficient electric heat pump water heaters on the market today. Rebecca Matulka Rebecca Matulka Former Digital Communications Specialist, Office of Public Affairs Got Energy Efficiency

  3. High voltage bus and auxiliary heater control system for an electric or hybrid vehicle

    DOE Patents [OSTI]

    Murty, Balarama Vempaty

    2000-01-01

    A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

  4. Comparison of Advanced Residential Water Heating Technologies in the United States

    SciTech Connect (OSTI)

    Maguire, J.; Fang, X.; Wilson, E.

    2013-05-01

    Gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the US installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many preexisting models were used, new models of condensing and heat pump water heaters were created specifically for this work.

  5. Thermostatically controlled portable electric space heater with automatic temperature setback for energy saving

    SciTech Connect (OSTI)

    Shao, S.

    1994-01-11

    An electrically-powered portable space heater of the type having one or more vertically extending fin-tube heating elements disposed within an elongated housing has a selectively adjustable temperature controller responsive to a signal from an upwardly extending thermistor externally pivotally mounted on the rear of the heater housing for movement from a storage position behind the housing to an upraised operative position, thermistor also being used to supply a room temperature signal to an ambient temperature display device on the heater housing. Furthermore, the heater includes a selectively actuatable energy saving feature which, when actuated, automatically reduces by 5 degrees F. after a period of one hour the temperature to which the heater has been pre-set by the operator. 17 figs.

  6. Solar water heating: FEMP fact sheet

    SciTech Connect (OSTI)

    Clyne, R.

    1999-09-30

    Using the sun to heat domestic water makes sense in almost any climate. Solar water heaters typically provide 40 to 80{percent} of a building's annual water-heating needs. A solar water-heating system's performance depends primarily on the outdoor temperature, the temperature to which the water is heated, and the amount of sunlight striking the collector.

  7. Energy Conservation Program for Consumer Products: Energy Conservation Standards for Direct Heating Equipment and Pool Heaters, Request for Information

    Office of Energy Efficiency and Renewable Energy (EERE)

    Energy Conservation Program for Consumer Products: Energy Conservation Standards for Direct Heating Equipment and Pool Heaters, Request for Information

  8. Thermal performance of packed-bed solar air heaters

    SciTech Connect (OSTI)

    Sharma, S.P.; Saini, J.S.; Varma, H.K. )

    1991-01-01

    This paper presents an experimental investigation of the enhancement of thermal performance of solar iar heater having its duct packed with blackened wire-screen matrices. Tests were conducted to cover wide range of influencing parameters including geometry of wire screens, mass flow rates and input solar energy fluxes under actual outdoor conditions. Effect of these parameters on the thermal performance has been investigated and results have been compared with those of plane (flat-plate) collectors. These tests provide useful data for rating wire-screen matrices packed-bed collectors based on thermal performance. It is observed that the performance of plane collector improves appreciably by packing its duct with blackened wire-screen matrices and this improvement is a strong function of bed and operating parameters.

  9. Optimal thermohydraulic performance of artifically roughened solar air heaters

    SciTech Connect (OSTI)

    Prasad, B.N.; Saini, J.S. )

    1991-01-01

    The heat transfer coefficient of solar air heaters can be increased by providing artificial roughness on the bottom of the absorber plate, leading to higher collection efficiency. Inclusion of artificial roughness, however, results in a higher friction factor and consequently a higher pumping power is required. Results show that both the Nusselt number and friction factor increase with increasing relative roughness height and decrease with increasing relative roughness pitch, but not in direct proportions. Optimization of the roughness and flow parameters (p/e, e/D, Re) to maximize heat transfer while keeping friction losses minimum was attempted. It has been found that a particular value of roughness Reynolds number (e{sup +} = e/D {radical}{ovr f/2Re}), always corresponds to optimum thermohydraulic conditions in the range of parameters investigated. On this basis design curves have been developed that give the optimal thermohydraulic performance combination of these parameters.

  10. TIP #: Project Name

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Response: Heat Pump Water Heater vs. Electric Resistance Demonstration of 2nd Generation Ducted GE "Brillion" Hybrid Water Heater in the PNNL Lab Homes Sarah Widder Research...

  11. Validation of a Hot Water Distribution Model Using Laboratory and Field Data

    SciTech Connect (OSTI)

    Backman, C.; Hoeschele, M.

    2013-07-01

    Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the Building America research team ARBI validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. This project also looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. The team concluded that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws, which has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

  12. Grid-Interactive Renewable Water Heating Economic and Environmental Value

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1 Grid-Interactive Renewable Water Heating Economic and Environmental Value Grid-interactive renewable water heaters have smart controls that quickly change their charge rate and charge level, factoring in renewable generation and other critical needs of the grid; thereby significantly reducing carbon emissions and bringing a new dimension of conservation and efficiency to the electric grid. The Steffes grid-interactive renewable water heater controller provides utilities with an affordable and

  13. Expert Meeting Report. Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems

    SciTech Connect (OSTI)

    Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

    2012-06-01

    This Building America expert meeting was held on 7/31/2011, in Westford, Massachusetts. Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic.

  14. Property:Building/SPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters...

    Open Energy Info (EERE)

    Datasets Community Login | Sign Up Search Property Edit with form History Property:BuildingSPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters Jump to: navigation, search This is...

  15. Efficient graphite ring heater suitable for diamond-anvil cells to 1300 K

    SciTech Connect (OSTI)

    Du Zhixue; Amulele, George; Lee, Kanani K. M.; Miyagi, Lowell

    2013-02-15

    In order to generate homogeneous high temperatures at high pressures, a ring-shaped graphite heater has been developed to resistively heat diamond-anvil cell (DAC) samples up to 1300 K. By putting the heater in direct contact with the diamond anvils, this graphite heater design features the following advantages: (1) efficient heating: sample can be heated to 1300 K while the DAC body temperature remains less than 800 K, eliminating the requirement of a special alloy for the DAC; (2) compact design: the sample can be analyzed with in situ measurements, e.g., x-ray, optical, and electrical probes are possible. In particular, the side access of the heater allows for radial x-ray diffraction (XRD) measurements in addition to traditional axial XRD.

  16. Light-Weight Radioisotope Heater Unit final safety analysis report (LWRHU-FSAR): Volume 1: A. Introduction and executive summary: B. Reference Design Document (RDD)

    SciTech Connect (OSTI)

    Johnson, E.W.

    1988-10-01

    The orbiter and probe portions of the National Aeronautics and Space Administration (NASA) Galileo spacecraft contain components which require auxiliary heat during the mission. To meet these needs, the Department of Energy's (DOE's) Office of Special Applications (OSA) has sponsored the design, fabrication, and testing of a one-watt encapsulated plutonium dioxide-fueled thermal heater named the Light-Weight Radioisotope Heater Unit (LWRHU). This report, prepared by Monsanto Research Corporation (MRC), addresses the radiological risks which might be encountered by people both at the launch area and worldwide should postulated mission failures or malfunctions occur, resulting in the release of the LWRHUs to the environment. Included are data from the design, mission descriptions, postulated accidents with their consequences, test data, and the derived source terms and personnel exposures for the various events. 11 refs., 44 figs., 11 tabs.

  17. Portable, flueless, low NO sub x , low CO space heater

    SciTech Connect (OSTI)

    Kardas, A.

    1990-09-25

    This patent describes a flueless, portable space heater. It comprises: a fuel chamber having a fuel inlet and fuel distributing means, fuel swirling means for generating a swirling fuel flow; a primary air chamber, primary air swirling means for generating a counter-swirling primary air flow with respect to the swirling fuel flow; at least one combustion chamber wall forming a combustion chamber sealably secured to and in communication with the primary air swirling means, secondary air inlet means; mediate shell surrounding the at least one combustion chamber wall; a top and a bottom sealing the space, a secondary air inlet in communication with the space. The bottom having at least one bottom plate through hole, at least one secondary air inlet tube sealably secured to the bottom and in communication with the at least one bottom plate through hole, each the bottom plate through hole in communication with the space between the intermediate shell and the at least one combustion chamber wall; and an outer protective shell surrounding and supportably spaced from the at least one combustion chamber wall of the combustion chamber.

  18. Light-Weight Radioisotope Heater Unit (LWRHU) sequential impact tests

    SciTech Connect (OSTI)

    Reimus, M.A.H.; Rinehart, G.H.

    1997-08-01

    The light-weight radioisotope heater unit (LWRHU) is a {sup 238}PuO{sub 2}-fueled heat source designed to provide one thermal watt in each of various locations on a spacecraft. Los Alamos National Laboratory designed, fabricated, and safety tested the LWRHU. The heat source consists of a hot-pressed {sup 238}PuO{sub 2} fuel pellet, a Pt-30Rh vented capsule, a pyrolytic graphite insulator, and a fineweave-pierced fabric graphite aeroshell assembly. A series of sequential impacts tests using simulant-fueled LWRHU capsules was recently conducted to determine a failure threshold. Sequential impacting, in both end-on and side-on orientations, resulted in increased damage with each subsequent impact. Although the tests were conducted until the aeroshells were sufficiently distorted to be out of dimensional specification, the simulant-fueled capsules used in these tests were not severely deformed. Sequential impacting of the LWRHU appears to result in slightly greater damage than a single impact at the final impact velocity of 50 m/s. Postimpact examination revealed that the sequentially impacted capsules were slightly more deformed and were outside of dimensional specifications.

  19. Light-weight radioisotope heater unit (LWRHU) impact tests

    SciTech Connect (OSTI)

    Reimus, M. A. H.; Rinehart, G. H.; Herrera, A.; Lopez, B.; Lynch, C.; Moniz, P.

    1998-01-15

    The light-weight radioisotope heater unit (LWRHU) is a {sup 238}PuO{sub 2}-fueled heat source designed to provide one thermal watt in each of various locations on a spacecraft. Los Alamos National Laboratory designed, fabricated, and safety tested the LWRHU. The heat source consists of a hot-pressed {sup 238}PuO{sub 2} fuel pellet, a Pt-30Rh vented capsule, a pyrolytic graphite insulator, and a fineweave-pierced fabric graphite aeroshell assembly. To compare the performance of the LWRHUs fabricated for the Cassini mission with the performance of those fabricated for the Galileo mission, and to determine a failure threshold, two types of impact tests were conducted. A post-reentry impact test was performed on one of 180 flight-quality units produced for the Cassini mission and a series of sequential impact tests using simulant-fueled LWRHU capsules were conducted respectively. The results showed that deformation and fuel containment of the impacted Cassini LWRHU was similar to that of a previously tested Galileo LWRHU. Both units sustained minimal deformation of the aeroshell and fueled capsule; the fuel was entirely contained by the platinum capsule. Sequential impacting, in both end-on and side-on orientations, resulted in increased damage with each subsequent impact. Sequential impacting of the LWRHU appears to result in slightly greater damage than a single impact at the final impact velocity of 50 m/s.

  20. Light-weight radioisotope heater unit (LWRHU) impact tests

    SciTech Connect (OSTI)

    Reimus, M.A.; Rinehart, G.H.; Herrera, A.; Lopez, B.; Lynch, C.; Moniz, P.

    1998-01-01

    The light-weight radioisotope heater unit (LWRHU) is a {sup 238}PuO{sub 2}-fueled heat source designed to provide one thermal watt in each of various locations on a spacecraft. Los Alamos National Laboratory designed, fabricated, and safety tested the LWRHU. The heat source consists of a hot-pressed {sup 238}PuO{sub 2} fuel pellet, a Pt-30Rh vented capsule, a pyrolytic graphite insulator, and a fineweave-pierced fabric graphite aeroshell assembly. To compare the performance of the LWRHUs fabricated for the Cassini mission with the performance of those fabricated for the Galileo mission, and to determine a failure threshold, two types of impact tests were conducted. A post-reentry impact test was performed on one of 180 flight-quality units produced for the Cassini mission and a series of sequential impact tests using simulant-fueled LWRHU capsules were conducted respectively. The results showed that deformation and fuel containment of the impacted Cassini LWRHU was similar to that of a previously tested Galileo LWRHU. Both units sustained minimal deformation of the aeroshell and fueled capsule; the fuel was entirely contained by the platinum capsule. Sequential impacting, in both end-on and side-on orientations, resulted in increased damage with each subsequent impact. Sequential impacting of the LWRHU appears to result in slightly greater damage than a single impact at the final impact velocity of 50 m/s. {copyright} {ital 1998 American Institute of Physics.}