Improved Air Volume Control Logic for VAV Systems  

E-Print Network [OSTI]

position of the terminal boxes. This method is called air volume control logic. Under this control logic, terminal box airflow requirements are met with reduced static pressure. Fan power consumption is minimized. However, the actual system performance also...

Wei, G.; Claridge, D. E.; Sakuri, Y.; M. Liu

2000-01-01T23:59:59.000Z

2

Application of Wireless Sensor Network (WSN) Technologies in Optimal Static Pressure Reset in Variable Air Volume (VAV) System  

E-Print Network [OSTI]

Optimization of the static pressure reset is always critical in the pursuit of maximum savings of fan power and thermal energy consumption in a VAV system. This paper theoretically investigated three static pressure reset methods, i.e. VAV terminal...

Zheng, K.; Li, H.; Yang, H.

2007-01-01T23:59:59.000Z

3

Energy Savings for Occupancy-Based Control (OBC) of Variable-Air-Volume (VAV) Systems  

SciTech Connect (OSTI)

This study evaluates the savings potential of occupancy based control (OBC) for large office buildings with VAV terminal boxes installed.

Zhang, Jian; Lutes, Robert G.; Liu, Guopeng; Brambley, Michael R.

2013-01-24T23:59:59.000Z

4

Commissioning and Diagnosis of VAV Air-Conditioning Systems  

E-Print Network [OSTI]

This paper presents a fault detection and diagnosis (FDD) strategy based on system knowledge, qualitative states and object-oriented statistical process control (SPC) models for typical pressure-independent variable air volume (VAV) air...

Qin, J.; Wang, S.; Chan, C.; Xiao, F.

2006-01-01T23:59:59.000Z

5

Variable Speed Drive Volumetric Tracking (VSDVT) for Airflow Control in Variable Air Volume (VAV) Systems  

E-Print Network [OSTI]

Volume Systems.? Proceedings of ACEEE 1994 Summer Study on Energy Efficiency in Buildings, Vol. 5, pp. 219-223. 3. Liu M., Zhu Y., Claridge D.E., and White E., 1997. ?Impact of Static Pressure Set Level on HVAC Energy Consumption and Indoor... developed to ensure the air delivery to each space or zone. These methods include the static pressure control method and the damper position control method. The static pressure control method maintains a sufficient static pressure in the main duct...

Liu, M.

2002-01-01T23:59:59.000Z

6

Final Project Report: Self-Correcting Controls for VAV System Faults Filter/Fan/Coil and VAV Box Sections  

SciTech Connect (OSTI)

This report addresses original research by the Pacific Northwest National Laboratory for the California Institute for Energy and Environment on self-correcting controls for variable-air-volume (VAV) heating, ventilating and air-conditioning systems and focuses specifically on air handling and VAV box components of the air side of the system. A complete set of faults for these components was compiled and a fault mode analysis performed to understand the detectable symptoms of the faults and the chain of causation. A set of 26 algorithms was developed to facilitate the automatic correction of these faults in typical commercial VAV systems. These algorithms include training tests that are used during commissioning to develop models of normal system operation, passive diagnostics used to detect the symptoms of faults, proactive diagnostics used to diagnose the cause of a fault, and finally fault correction algorithms. Ten of the twenty six algorithms were implemented in a prototype software package that interfaces with a test bed facility at PNNL's Richland, WA, laboratory. Measurement bias faults were instigated in the supply-air temperature sensor and the supply-air flow meter to test the algorithms developed. The algorithms as implemented in the laboratory software correctly detected, diagnosed and corrected these faults. Finally, an economic and impact assessment was performed for the State of California for deployment of self-correcting controls. Assuming 15% HVAC energy savings and a modeled deployment profile, 3.1-5.8 TBu of energy savings are possible by year 15.

Brambley, Michael R.; Fernandez, Nicholas; Wang, Weimin; Cort, Katherine A.; Cho, Heejin; Ngo, Hung; Goddard, James K.

2011-05-01T23:59:59.000Z

7

Duct leakage impacts on VAV system performance in California large commercial buildings  

SciTech Connect (OSTI)

The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. Based on our analyses of the 54 simulation cases, the increase in annual fan energy is estimated to be 40 to 50% for a system with a total leakage of 19% at design conditions compared to a tight system with 5% leakage. Annual cooling plant energy also increases by about 7 to 10%, but reheat energy decreases (about 3 to 10%). In combination, the increase in total annual HVAC site energy is 2 to 14%. The total HVAC site energy use includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption. Using year 2000 average commercial sector energy prices for California ($0.0986/kWh and $7.71/Million Btu), the energy increases result in 9 to 18% ($7,400 to $9,500) increases in HVAC system annual operating costs. Normalized by duct surface area, the increases in annual operating costs are 0.14 to 0.18 $/ft{sup 2}. Using a suggested one-time duct sealing cost of $0.20 per square foot of duct surface area, these results indicate that sealing leaky ducts in VAV systems has a simple payback period of about 1.3 years. Even with total leakage rates as low as 10%, duct sealing is still cost effective. This suggests that duct sealing should be considered at least for VAV systems with 10% or more total duct leakage. The VAV system that we simulated had perfectly insulated ducts, and maintained constant static pressure in the ducts upstream of the VAV boxes and a constant supply air temperature at the airhandler. Further evaluations of duct leakage impacts should be carried out in the future after methodologies are developed to deal with duct surface heat transfer effects, to deal with airflows entering VAV boxes from ceiling return plenums (e.g., to model parallel fan-powered VAV boxes), and to deal with static pressure reset and supply air temperature reset strategies.

Wray, Craig P.; Matson, Nance E.

2003-10-01T23:59:59.000Z

8

Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part I: Theoretical Model and Simulation  

E-Print Network [OSTI]

As for a variable air volume (VAV) system, the air duct static pressure is a typical control variable maintained by modulating supply fan speed. The static pressure equals to the summation of the duct pressure loss downstream of the sensor...

Liu, M.; Feng, J.; Wang, Z.; Wu, L.; Zheng, K.; Pang, W.

2007-01-01T23:59:59.000Z

9

Stability limit of room air temperature of a VAV system  

SciTech Connect (OSTI)

To control heating, ventilating, and air-conditioning (HVAC) systems, it has been necessary to accept an analog system controlled mainly by proportional-plus-integral-plus-derivative (PID) action. However, when conventional PID controllers are replaced with new digital controllers by selecting the same PID parameters as before, the control loops have often got into hunting phenomena, which result in undamped oscillations. Unstable control characteristics (such as huntings) are thought to be one of the crucial problems faced by field operators. The PID parameters must be carefully selected to avoid instabilities. In this study, a room space is simulated as a thermal system that is air-conditioned by a variable-air-volume (VAV) control system. A dynamic room model without infiltration or exfiltration, which is directly connected to a simple air-handling unit without an economizer, is developed. To explore the possible existence of huntings, a numerical system model is formulated as a bilinear system with time-delayed feedback, and a parametric analysis of the stability limit is presented. Results are given showing the stability region affected by the selection of control and system parameters. This analysis was conducted to help us tune the PID controllers for optimal HVAC control.

Matsuba, Tadahiko; Kamimura, Kazuyuki [Yamatake-Honeywell Co., Ltd., Tokyo (Japan). Building System Div.; Kasahara, Masato; Kimbara, Akiomi; Kurosu, Shigeru [Oyama National Coll. of Technology (Japan); Murasawa, Itaru; Hashimoto, Yukihiko [Tonets Corp., Tokyo (Japan). Engineering Project Dept.

1998-12-31T23:59:59.000Z

10

The Energy Saving Potential of Membrane-Based Enthalpy Recovery in Vav Systems for Commercial  

E-Print Network [OSTI]

, high effectiveness enthalpy exchanger in two US cities representing a range of humid climates and the results showed savings of up to 8% in annual energy consumption in a humid climate. The purposesLBNL-6032E The Energy Saving Potential of Membrane-Based Enthalpy Recovery in Vav Systems

11

Theoretical Study of a Novel Control Method of VAV Air-conditioning System Based on MATLAB  

E-Print Network [OSTI]

). If the system can be transformed into linear system by mathematic method, control strategy will be simplified. It is noted that differential geometry theory is applicable to simplify the system described by equation (4). 3. DIFFERENTIABLE HOMEOMORPHI..., stability and other aspects. Key words: VAV; differentiable homeomorphism; nonlinear feedback; simulation 1. INTRODUCTION In order to maintain indoor air temperature at set value, there are two methods in the air-conditioning system. One method...

Shi, Z.; Hu, S.; Wang, G.; Li, A.

2006-01-01T23:59:59.000Z

12

Problem of Vain Energy Consumption in a VAV Air Conditioning System Shared By an Inner Zone and Exterior Zone  

E-Print Network [OSTI]

in winter and summer. Taking a practical project as example, this paper analyzes the energy consumption of a VAV air conditioning system that is shared by inner zone and exterior zone. The paper also points out the serious problem of useless energy...

Wenji, G.; Ling, C.; Dongdong, L.; Mei, S.; Li, Z.

2006-01-01T23:59:59.000Z

13

The Optimization of Control Parameters for VAV HVAC System Commissioning  

E-Print Network [OSTI]

One of the technical subjects in commissioning for HVAC system is to enhance control performance and time efficiency, while the tuning of the optimal parameters to control HVAC system takes much time and labor in particular. Therefore, we propose a...

Song, S.; Maehara, K.; Sagara, N.

2006-01-01T23:59:59.000Z

14

A New Approach to Commissioning of the VAV Control System  

E-Print Network [OSTI]

. Hyvarinen, S. Karki. Building optimization and fault diagnosis source book. IEA Annex (1996) 25 [3] H. Yoshida, T. Iwami, H. Yuzawa, M. Suzuki. Typical faults of airconditioning systems and fault detection by ARX model and extended Kalman Filter. ASHRAE...

Han, Z.; Xia, C.; Zhu, Y.; Xu, G.

2006-01-01T23:59:59.000Z

15

Building Pressure Control in VAV System with Relief Air Fan  

E-Print Network [OSTI]

, recently, Wang and Liu developed a motor power based fan airflow station., which determines the fan airflow using the measured fan motor power, the fan speed or control system command to VFD, and the in-situ fan motor power curve. Since the fan power... power can be obtained directly from VFD [5]. The motor power based fan airflow station method can be applied to the fan-tracking to perform a better building pressurization. The theory of the motor power based fan airflow station can be referred...

Pang, X.; Liu, M.; Zheng, B.

2005-01-01T23:59:59.000Z

16

VAV System Optimization through Continuous Commissioning in an Office Building  

E-Print Network [OSTI]

control Existing schedule: The existing control modulates the relief fan VFD to maintain the building pressure at its set-point (0.02 in.W.C). The relief damper is modulated according to the relief fan VFD speed. Table 3. Outside air damper.... AHU 2 serves the 3 rd , 4 th and 5 th floors. Both use similar control sequences, except that some parameter settings differ. The supply fans and relief fans have their respective VFD controls. One single-duct AHU system is shown in Figure 2...

Cho, Y.; Pang, X.; Liu, M.

2007-01-01T23:59:59.000Z

17

Field testing of component-level model-based fault detection methods for mixing boxes and VAV fan systems  

SciTech Connect (OSTI)

An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests of the sort using in commissioning. This paper presents the results of field tests of mixing box and VAV fan system models in an experimental facility and a commercial office building. The models were found to be capable of representing the performance of correctly operating mixing box and VAV fan systems and detecting several types of incorrect operation.

Xu, Peng; Haves, Philip

2002-05-16T23:59:59.000Z

18

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation  

E-Print Network [OSTI]

, is the fan power consumption, cfm is the air flow rate, and cfr&, is the designed air flow rate. In the base cases, the cold deck temperature is 55°F regardless of the ambient temperature. The hot deck temperature varies from 1 10°F to 75°F when... the ambient temperature increases from 40°F to 75OF. When the ambient temperature is lower than 40°F, the hot deck temperature remains at 1 10°F. Figure 5: Cold and Hot Deck Temperature Versus the Ambient Temperature for Base Case or Normal VAV System...

Liu, M.; Claridge, D. E.

1998-01-01T23:59:59.000Z

19

System dynamics based models for selecting HVAC systems for office buildings: a life cycle assessment from carbon emissions perspective.  

E-Print Network [OSTI]

??This study aims to explore the life cycle environmental impacts of typical heating ventilation and air condition (HVAC) systems including variable air volume (VAV) system,… (more)

Chen, S

2011-01-01T23:59:59.000Z

20

Optimization of supply air temperature reset schedule for a single duct VAV systems  

E-Print Network [OSTI]

In a single duct variable air volume (SDVAV) system, the supply air temperature is usually set as a constant value. Since this constant setpoint is selected to satisfy the maximum cooling load conditions, significant reheat will occur once...

Fan, Wenshu

2009-05-15T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

A Case Study of Continuous Commissioning of the VAV System in China  

E-Print Network [OSTI]

deviation is obtained, OCM (Objective Control Method) should be applied to diagnose the performance of control system, which is introduced in detail by Zheng Han[9]. If deviation is small or step 2 is completed, evaluation of indoor environment quality... Integrated analysis method for continuous Cx Lots of techniques, models and measurement methods can be found for step1 and step3, while research and application of OCM in this project has been explained by Zheng Han[9]. This paper mainly focuses...

Xia, C.; Zhu, Y.; Chen, H.; Han, Z.; Xu, G.

2006-01-01T23:59:59.000Z

22

The St. Louis Chapter, ASHRAE Newsletter VOLUME 23, NUMBER 6 http://www.ashrae-stl.org March 2006  

E-Print Network [OSTI]

, retail, sports complexes, chiller installations, VAV systems, raised floor computer facilities, DDC

Missouri-Rolla, University of

23

Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part 2: Case Demonstration for a Typical Climate System  

E-Print Network [OSTI]

. In this part, a simulated air handling unit (AHU) system in Omaha NE is used to demonstrate the energy savings performance in one typical climate year. This AHU system has a static pressure reset system and two constant static pressure systems, one having...

Liu, M.; Zheng, K.; Wu, L.; Wang, Z.; Johnson, C.

2007-01-01T23:59:59.000Z

24

Procedure and Application for Determining the Cold Deck and Hot Deck Airflow in a Dual-Duct System  

E-Print Network [OSTI]

This paper introduces an innovative method to determine the cold and hot airflow through a dual-duct variable air volume (VAV) system. The actual building load can be identified based on the calculated airflow and temperature for both the cold...

Liu, G.; Mingsheng, L.

2006-01-01T23:59:59.000Z

25

Development of a Laboratory Verified Single-Duct VAV System Model with Fan Powered Terminal Units Optimized Using Computational Fluid Dynamics  

E-Print Network [OSTI]

the harmonics generated by ECM systems. All research objectives were achieved. The CFD model, which was verified with laboratory measurements, showed the potential to identify opportunities for improvement in the design of the FPTU and accurately predicted...

Davis, Michael A.

2011-10-21T23:59:59.000Z

26

Thermal and air quality acceptability in buildings that reduce energy by reducing minimun airflow from overhead diffusers  

E-Print Network [OSTI]

for rating the performance of air outlets and inlets. ANSI/comfort with a variable air volume (VAV) system. InternalGuidelines: Advanced Variable Air Volume (VAV) Systems.

2012-01-01T23:59:59.000Z

27

Performance of VAV Fan Powered Terminal Units: Experimental Results and Models for Parallel Units  

E-Print Network [OSTI]

consists of a central air handling unit (AHU), where air is cooled by cooling coils (Wendes 1994). This air, referred to as primary air, is sent through a single-duct supply system to VAV terminal units by the supply fan. Each terminal unit is ducted to air... surprise that the flow regressed well with the square root of the pressure differential across the terminal unit at a given damper setting and showed no dependence on SCR. The construction quality of these terminal units could be an item of concern...

Furr, J.; O'Neal, D.; Davis, M.; Bryant, J.; Cramlet, A.

28

Implementation of the Laboratory Air Handling Unit Systems (LAHU)  

E-Print Network [OSTI]

Implementation of the Laboratory Air Handling Unit Systems (LAHU) Y. Cui Graduate Student Energy Systems Laboratory University of Nebraska-Lincoln Omaha, NE, USA M. Liu, Ph.D., P.E. Associate Professor Energy Systems Laboratory...-around coils [18, 19], the variable air volume (VAV) fume hoods [8-16] and the usage-based control devices (UBC) [17]. These measures have effectively reduced the cooling energy, preheat energy and fan power consumption, and sometime, improved indoor...

Cui, Y.; Liu, M.; Conger, K.

2003-01-01T23:59:59.000Z

29

Fault Detection and Diagnosis Method for VAV Terminal Units  

E-Print Network [OSTI]

: Air density [kg/m3] NOMENCLATURE REFERENCES 1) IEA Annex 25, Building Optimization and Fault Diagnosis Source Book, Eds. J. Hyvarinen and S. Karki, Technical Research Center of Finland, 1996 2) Harunori Yoshida: Typical Faults of Air Conditioning..., IEA Annex 34 ?Detection and Diagnosis Methods in Real Building?, Eds. A. Dexter and J. Pakanen, Section C.2, pp.143-148, 2001 6) Harunori Yoshida, Sanjay Kumar, Yasunori Morita: Online Fault Detection and Diagnosis in VAV Air Handling Unit by RARX...

Miyata, M.; Yoshida, H.; Asada, M.; Wang, F.; Hashiguchi, S.

2004-01-01T23:59:59.000Z

30

Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models  

E-Print Network [OSTI]

ESL-TR-91/12-03 ENERGY SYSTEMS LABORATORY TECHNICAL REPORT REPRINTED WITH PERMISSION Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models Srinivas Katipamula, P.... Texas 77843 (409) 845-6402. or (409) 845-3251 INTRODUCTION Several state owned buildings with dual-duct constant volume (DDCV) systems have been retrofitted with energy efficient variable air volume systems (VAV) as part of the Texas LoanSTAR Program...

Katipamula, S.; Claridge, D. E.

1991-01-01T23:59:59.000Z

31

Electric, Gas, and Electric/Gas Energy Options for Cold-Air HVAC Systems  

E-Print Network [OSTI]

and incorporated into HVAC design for medium-to-large buildings, it is possible to structure system arrangements that reduce energy operating costs very significantly compared to conventional all-air VAV systems and also to all-air VAV ice thermal storage systems...

Meckler, G.

1989-01-01T23:59:59.000Z

32

 Underfloor air distribution (UFAD) cost study: analysis of first cost tradeoffs in UFAD systems  

E-Print Network [OSTI]

is served by VAV fan coil units (FCU) with variable speedwith regard to terminal fan coil unit costs. Since the modelfan powered boxes with hot water reheat coils. Because it is a constant volume unit,

Webster, Tom; Benedek, Corinne; Bauman, Fred

2006-01-01T23:59:59.000Z

33

CALIFORNIA ENERGY Advanced Variable Air Volume  

E-Print Network [OSTI]

on VAV airside system design. Total large office building energy savings of up to 12% are achievable and controls for commercial buildings and in performing peer reviews of mechanical designs of commercial was developed as part of the Integrated Energy Systems -- Productivity and Building Science project, a Public

34

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

Four Pipe Fan Coil; Four Pipe Induction Unit; Heating andTwo Pipe Fan Coil; Two Pipe Induction Unit; Unit Heater;units (AHUs) – four CAV systems, four VAV systems, and one fan coil

Zhou, Xin

2014-01-01T23:59:59.000Z

35

CIRMIS Data system. Volume 2. Program listings  

SciTech Connect (OSTI)

The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (OWNI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. Analysis of the long-term, far-field consequences of release scenarios requires the application of numerical codes which simulate the hydrologic systems, model the transport of released radionuclides through the hydrologic systems, model the transport of released radionuclides through the hydrologic systems to the biosphere, and, where applicable, assess the radiological dose to humans. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for utilization by the hydraulic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required.The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System is a storage and retrieval system for model input and output data, including graphical interpretation and display. This is the second of four volumes of the description of the CIRMIS Data System.

Friedrichs, D.R.

1980-01-01T23:59:59.000Z

36

Design of a dual port volume measuring system  

SciTech Connect (OSTI)

A volume measuring system is described which uses the ideal gas law and pressure measurements to determine an unknown vessel's volume when a gas expands into that vessel from a known volume. The design, the engineering principles, the calibration, and the accuracy of this computer-controlled system are all discussed. A set of electrical and mechanical drawings of the system is included. 3 refs., 6 figs.

Klevgard, P.A.

1990-09-01T23:59:59.000Z

37

VAV Reheat Versus Active Chilled Beams and DOAS  

E-Print Network [OSTI]

and Pollutant Source Control) – This credit is generally achievable with a VAVR system since it requires that all supply air

Stein, Jeff; Taylor, Steven

2013-01-01T23:59:59.000Z

38

Two-Nucleon Systems in a Finite Volume  

SciTech Connect (OSTI)

I present the formalism and methodology for determining the nucleon-nucleon scattering parameters from the finite volume spectra obtained from lattice quantum chromodynamics calculations. Using the recently derived energy quantization conditions and the experimentally determined scattering parameters, the bound state spectra for finite volume systems with overlap with the 3S1-3D3 channel are predicted for a range of volumes. It is shown that the extractions of the infinite-volume deuteron binding energy and the low-energy scattering parameters, including the S-D mixing angle, are possible from Lattice QCD calculations of two-nucleon systems with boosts of |P| <= 2pi sqrt{3}/L in volumes with spatial extents L satisfying fm <~ L <~ 14 fm.

Briceno, Raul

2014-11-01T23:59:59.000Z

39

The KamLAND Full-Volume Calibration System  

SciTech Connect (OSTI)

We have successfully built and operated a source deployment system for the KamLAND detector. This system was used to position radioactive sources throughout the delicate 1-kton liquid scintillator volume, while meeting stringent material cleanliness, material compatibility, and safety requirements. The calibration data obtained with this device were used to fully characterize detector position and energy reconstruction biases. As a result, the uncertainty in the size of the detector fiducial volume was reduced by a factor of two. Prior to calibration with this system, the fiducial volume was the largest source of systematic uncertainty in measuring the number of antineutrinos detected by KamLAND. This paper describes the design, operation and performance of this unique calibration system.

KamLAND Collaboration; Berger, B. E.; Busenitz, J.; Classen, T.; Decowski, M. P.; Dwyer, D. A.; Elor, G.; Frank, A.; Freedman, S. J.; Fujikawa, B. K.; Galloway, M.; Gray, F.; Heeger, K. M.; Hsu, L.; Ichimura, K.; Kadel, R.; Keefer, G.; Lendvai, C.; McKee, D.; O'Donnell, T.; Piepke, A.; Steiner, H. M.; Syversrud, D.; Wallig, J.; Winslow, L. A.; Ebihara, T.; Enomoto, S.; Furuno, K.; Gando, Y.; Ikeda, H.; Inoue, K.; Kibe, Y.; Kishimoto, Y.; Koga, M.; Minekawa, Y.; Mitsui, T.; Nakajima, K.; Nakajima, K.; Nakamura, K.; Owada, K.; Shimizu, I.; Shimizu, Y.; Shirai, J.; Suekane, F.; Suzuki, A.; Tamae, K.; Yoshida, S.; Kozlov, A.; Murayama, H.; Grant, C.; Leonard, D. S.; Luk, K.-B.; Jillings, C.; Mauger, C.; McKeown, R. D.; Zhang, C.; Lane, C. E.; Maricic, J.; Miletic, T.; Batygov, M.; Learned, J. G.; Matsuno, S.; Pakvasa, S.; Foster, J.; Horton-Smith, G. A.; Tang, A.; Dazeley, S.; Downum, K. E.; Gratta, G.; Tolich, K.; Bugg, W.; Efremenko, Y.; Kamyshkov, Y.; Perevozchikov, O.; Karwowski, H. J.; Markoff, D. M.; Tornow, W.; Piquemal, F.; Ricol, J.-S.

2009-03-05T23:59:59.000Z

40

Modeling the Earth System, volume 3  

SciTech Connect (OSTI)

The topics covered fall under the following headings: critical gaps in the Earth system conceptual framework; development needs for simplified models; and validating Earth system models and their subcomponents.

Ojima, D.

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

HVAC systems in the current stock of U. S. K-12 schools. Final report, May 91-Mar 92  

SciTech Connect (OSTI)

The report summarizes information on heating, ventilating, and air-conditioning (HVAC) systems commonly found in U.S. school buildings and the effect that operating these systems has on indoor radon levels. The report describes the ability of various HVAC systems to pressurize and ventilate classroom spaces, how they operate, and how they are controlled. Some information is given to compare systems from the standpoint of energy use, cost, and their ability to maintain stable levels of static pressure in classrooms and/or to adequately ventilate the spaces. There do not appear to be any well defined trends in types of HVAC systems involved in current school building construction and modification. Systems looked at include those using reheat and/or mixing, unit ventilators (UVs), and two-fan, dual-duct variable air volume (VAV) systems.

Parker, J.D.

1992-07-01T23:59:59.000Z

42

Remote-handled transuranic system assessment appendices. Volume 2  

SciTech Connect (OSTI)

Volume 2 of this report contains six appendices to the report: Inventory and generation of remote-handled transuranic waste; Remote-handled transuranic waste site storage; Characterization of remote-handled transuranic waste; RH-TRU waste treatment alternatives system analysis; Packaging and transportation study; and Remote-handled transuranic waste disposal alternatives.

NONE

1995-11-01T23:59:59.000Z

43

Recent Developments of the Modelica"Buildings" Library for Building Energy and Control Systems  

SciTech Connect (OSTI)

At the Modelica 2009 conference, we introduced the Buildings library, a freely available Modelica library for building energy and control systems. This paper reports the updates of the library and presents example applications for a range of heating, ventilation and air conditioning (HVAC) systems. Over the past two years, the library has been further developed. The number of HVAC components models has been doubled and various components have been revised to increase numerical robustness.The paper starts with an overview of the library architecture and a description of the main packages. To demonstrate the features of the Buildings library, applications that include multizone airflow simulation as well as supervisory and local loop control of a variable air volume (VAV) system are briefly described. The paper closes with a discussion of the current development.

Wetter, Michael; Zuo, Wangda; Nouidui, Thierry Stephane

2011-04-01T23:59:59.000Z

44

Shared Communications: Volume 2. In-Depth Systems Research  

SciTech Connect (OSTI)

This report is the second of two documents that examine the literature for actual examples of organizations and agencies that share communications resources. While the primary emphasis is on rural, intelligent transportation system (ITS) communications involving transit, examples will not be limited to rural activities, nor to ITS implementation, nor even to transit. In addition, the term ''communication'' will be broadly applied to include all information resources. The first document of this series, ''Shared Communications: Volume I. A Summary and Literature Review'', defines the meaning of the term ''shared communication resources'' and provides many examples of agencies that share resources. This document, ''Shared Communications: Volume II. In-Depth Systems Research'', reviews attributes that contributed to successful applications of the sharing communication resources concept. A few examples of each type of communication sharing are provided. Based on the issues and best practice realworld examples, recommendations for potential usage and recommended approaches for field operational tests are provided.

Truett, LF

2004-09-22T23:59:59.000Z

45

Variable Speed Drive (VSD) Applications in Dual-Duct Constant Volume Systems  

E-Print Network [OSTI]

Models have been developed for static pressure and potential supply fan energy savings by using variable speed drive (VSD) in dual-duct constant volume systems. Experiments have been performed using a full size dual-duct constant volume system...

Joo, I.; Liu, M.; Conger, K.; Wang, G.

2002-01-01T23:59:59.000Z

46

STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS  

E-Print Network [OSTI]

STATE OF CALIFORNIA CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC Volume Single Zone Unitary Air Conditioner and Heat Pump Systems (Page 1 of 4) Project Name CONSTANT VOLUME SINGLE ZONE UNITARY AIR CONDITIONER AND HEAT PUMP SYSTEMS CEC-MECH-3A (Revised 08

47

Nuclear reactor engineering: Reactor systems engineering. Fourth edition, Volume Two  

SciTech Connect (OSTI)

This new edition of this classic reference combines broad yet in-depth coverage of nuclear engineering principles with practical descriptions of their application in the design and operation of nuclear power plants. Extensively updated, the fourth edition includes new materials on reactor safety and risk analysis, regulation, fuel management, waste management and operational aspects of nuclear power. This volume contains the following: the systems concept, design decisions, and information tools; energy transport; reactor fuel management and energy cost considerations; environmental effects of nuclear power and waste management; nuclear reactor safety and regulation; power reactor systems; plant operations; and advanced plants and the future.

Glasstone, S.; Sesonske, A.

1994-12-31T23:59:59.000Z

48

Using fiberglass volumes for VPI of superconductive magnetic systems’ insulation  

SciTech Connect (OSTI)

The paper describes the method of manufacturing fiberglass molds for vacuum pressure impregnation (VPI) of high-voltage insulation of superconductive magnetic systems (SMS) with epoxidian hot-setting compounds. The basic advantages of using such vacuum volumes are improved quality of insulation impregnation in complex-shaped areas, and considerable cost-saving of preparing VPI of large-sized components due to dispensing with the stage of fabricating a metal impregnating volume. Such fiberglass vacuum molds were used for VPI of high-voltage insulation samples of an ITER reactor’s PF1 poloidal coil. Electric insulation of these samples has successfully undergone a wide range of high-voltage and mechanical tests at room and cryogenic temperatures. Some results of the tests are also given in this paper.

Andreev, I. S.; Bezrukov, A. A.; Pischugin, A. B. [Sredne-Nevskiy Shipyard (SNSZ), 10 Zavodskaya str., c. Pontonniy, Saint-Petersburg (Russian Federation); Bursikov, A. S.; Klimchenko, Y. A.; Marushin, E. L.; Mednikov, A. A.; Rodin, I. Y.; Stepanov, D. B. [The D.V. Efremov Scientific Research Institute of Electrophysical Apparatus (NIIEFA), 3 Doroga na Metallostroy, Metallostroy, Saint-Petersburg (Russian Federation)

2014-01-29T23:59:59.000Z

49

Flow Analysis on a Limited Volume Chilled Water System  

SciTech Connect (OSTI)

LANL Currently has a limited volume chilled water system for use in a glove box, but the system needs to be updated. Before we start building our new system, a flow analysis is needed to ensure that there are no high flow rates, extreme pressures, or any other hazards involved in the system. In this project the piping system is extremely important to us because it directly affects the overall design of the entire system. The primary components necessary for the chilled water piping system are shown in the design. They include the pipes themselves (perhaps of more than one diameter), the various fitting used to connect the individual pipes to form the desired system, the flow rate control devices (valves), and the pumps that add energy to the fluid. Even the most simple pipe systems are actually quite complex when they are viewed in terms of rigorous analytical considerations. I used an 'exact' analysis and dimensional analysis considerations combined with experimental results for this project. When 'real-world' effects are important (such as viscous effects in pipe flows), it is often difficult or impossible to use only theoretical methods to obtain the desired results. A judicious combination of experimental data with theoretical considerations and dimensional analysis are needed in order to reduce risks to an acceptable level.

Zheng, Lin [Los Alamos National Laboratory

2012-07-31T23:59:59.000Z

50

Model Based Commissioning Tool for Air-Conditioning Distribution Systems-APCBC  

E-Print Network [OSTI]

of VWV System 4. Example of VAV System 5. Conclusions 2 ESL-IC-14-09-06 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 ? Energy consumption of air and water distribution in air...-09-06 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 1. Issues 2. Simulation Model of Distribution System 3. Example of VWV System 4. Example of VAV System 5. Conclusions 7 ESL-IC-14...

Yoshida, H.; Noda, T.

2014-01-01T23:59:59.000Z

51

Entropy Production : From Open Volume Preserving to Dissipative Systems  

E-Print Network [OSTI]

We generalize Gaspard's method for computing the \\epsilon-entropy production rate in Hamiltonian systems to dissipative systems with attractors considered earlier by T\\'el, Vollmer, and Breymann. This approach leads to a natural definition of a coarse grained Gibbs entropy which is extensive, and which can be expressed in terms of the SRB measures and volumes of the coarse graining sets which cover the attractor. One can also study the entropy and entropy production as functions of the degree of resolution of the coarse graining process, and examine the limit as the coarse graining size approaches zero. We show that this definition of the Gibbs entropy leads to a positive rate of irreversible entropy production for reversible dissipative systems. We apply the method to the case of a two dimensional map, based upon a model considered by Vollmer, T\\'el and Breymann, that is a deterministic version of a biased-random walk. We treat both volume preserving and dissipative versions of the basic map, and make a comparison between the two cases. We discuss the \\epsilon-entropy production rate as a function of the size of the coarse graining cells for these biased-random walks and, for an open system with flux boundary conditions, show regions of exponential growth and decay of the rate of entropy production as the size of the cells decreases. This work describes in some detail the relation between the results of Gaspard, those of T\\'el, Vollmer and Breymann, and those of Ruelle, on entropy production in various systems described by Anosov or Anosov-like maps.

T. Gilbert; J. R. Dorfman

1999-03-11T23:59:59.000Z

52

Integrated Demand Controlled Ventilation for Single Duct VAV System with Conference Rooms  

E-Print Network [OSTI]

acceptable indoor air quality (IAQ), the overall outside air (OA) intake ratio has to consider the demands from all the zones with the method provided by ASHRAE 62. Some high-ventilation required rooms make it difficult to use a low OA intake ratio...

Yu, Y.; Liu, M.; Cho, Y.; Xu, K.

2007-01-01T23:59:59.000Z

53

Optimize the Supply Air Temperature Reset Schedule for a Single-Duct VAV System  

E-Print Network [OSTI]

air temperature. However, resetting the supply air temperature not only impacts the cooling and heating energy consumption, but also the fan power consumption. If reset improperly, it may cause indoor air humidity problems or result in a fan power...

Wei, G.; Claridge, D. E.; Liu, M.

2000-01-01T23:59:59.000Z

54

A Functional Test Procedure for the improved commissioning of a VAV system  

E-Print Network [OSTI]

by logically sequencing the operations according to the following order: 1) test in manual (ie not controlled by the BEMS) operation 2) test in manual (ie not controlled by the BEMS) stop 3) test in normal operation 4) test at maximum flowrate 5) test...

Andre, P.; Lacote, P.; Aparecida Silva, C.; Hannay, J.; Lebrun, J.

2004-01-01T23:59:59.000Z

55

Analysis of the Potential Energy Savings for 14 Office Buildings with VAV Systems  

E-Print Network [OSTI]

At the beginning of an existing building commissioning (EBCx)/energy retrofit project, some form of screening is usually applied to determine whether there is sufficient potential for savings to justify a formal EBCx assessment/energy audit...

Claridge, D. E.; Liu, J.; Baltazar, J. C.

2010-01-01T23:59:59.000Z

56

A Smart Logic for Conference Room Terminal Box of Single Duct VAV System  

E-Print Network [OSTI]

time, the minimum outside intake ratio for AHU side should be as low as possible to save energy. This study presents a smart logic to solve the confliction while improving thermal environment and saving energy consumption. The new control sequence...

Yu, Y.; Xu, K.; Cho, Y.; Liu, M.

2007-01-01T23:59:59.000Z

57

System 80+{trademark} Standard Design: CESSAR design certification. Volume 12: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 12, along with volume 13, provides accident analyses.

Not Available

1990-12-21T23:59:59.000Z

58

Preliminary Systems Design Study assessment report. Volume 8, Appendixes  

SciTech Connect (OSTI)

The System Design Study (SDS), part of the Waste Technology Development Department at the Idaho National Engineering Laboratory (INEL), examined techniques available for the remediation of hazardous and transuranic waste stored at the Radioactive Waste Management Complex`s Subsurface Disposal Area at the INEL. Using specific technologies, system concepts for treating the buried waste and the surrounding contaminated soil were evaluated. Evaluation included implementability, effectiveness, and cost. The SDS resulted in the development of technology requirements including demonstration, testing, and evaluation activities needed for implementing each concept. This volume of the Systems Design Study contain four Appendixes that were part of the study. Appendix A is an EG&G Idaho, Inc., report that represents a review and compilation of previous reports describing the wastes and quantities disposed in the Subsurface Disposal Area of the Idaho National Engineering Laboratory. Appendix B contains the process flowsheets considered in this study, but not selected for detailed analysis. Appendix C is a historical tabulation of radioactive waste incinerators. Appendix D lists Department of Energy facilities where cementation stabilization systems have been used.

Mayberry, J.L.; Feizollahi, F.; Del Signore, J.C.

1992-01-01T23:59:59.000Z

59

Modeling of ECM Controlled Series Fan-powered VAV Terminal Units  

E-Print Network [OSTI]

Semi-empirical models for series fan-powered variable air volume terminal units (FPTUs) were developed based on models of the primary, plenum, fan airflow and the fan power consumption. The experimental setups and test procedures were developed...

Yin, Peng

2011-10-21T23:59:59.000Z

60

System 80+{trademark} Standard Design: CESSAR design certification. Volume 3: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This report, Volume 3, in conjunction with Volume 2, provides the design of structures, components, equipment and systems.

Not Available

1990-12-21T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

System 80+{trademark} Standard Design: CESSAR design certification. Volume 2: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This report, Volume 2, in conjunction with Volume 3, provides the design of structures, components, equipment and systems.

Not Available

1990-12-21T23:59:59.000Z

62

System 80+{trademark} Standard Design: CESSAR design certification. Volume 9: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 9 discusses Electric Power and Auxiliary Systems.

Not Available

1990-12-21T23:59:59.000Z

63

System 80+{trademark} Standard Design: CESSAR design certification. Volume 10: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 10 discusses the Steam and Power Conversion System and Radioactive Waste Management.

Not Available

1990-12-21T23:59:59.000Z

64

State energy price system. Volume I: overview and technical documentation  

SciTech Connect (OSTI)

This study utilizes existing data sources and previous analyses of state-level energy prices to develop consistent state-level energy prices series by fuel type and by end-use sector. The fuels are electricity, natural gas, coal, distillate fuel oil, motor gasoline, diesel, kerosene, jet fuel, residual fuel, and liquefied petroleum gas. The end-use sectors are residential, commercial, industrial, transportation, and electric utility. Based upon an evaluation of existing data sources, recommendations were formulated on the feasible approaches for developing a consistent state energy price series. The data series were compiled based upon the approaches approved after a formal EIA review. Detailed documentation was provided, including annual updating procedures. Recommendations were formulated for future improvements in the collection of data or in data processing. Generally, the geographical coverage includes the 50 states and the District of Columbia. Information on state-level energy use was generally taken from the State Energy Data System (SEDS). Corresponding average US prices are also developed using volumes reported in SEDS. To the extent possible, the prices developed are quantity weighted average retail prices. Both a Btu price series and a physical unit price series are developed for each fuel. The period covered by the data series is 1970 through 1980 for most fuels, though prices for electricity and natural gas extend back to 1960. (PSB)

Fang, J.M.; Nieves, L.A.; Sherman, K.L.; Hood, L.J.

1982-06-01T23:59:59.000Z

65

Research on Fuzzy Regulation Strategies in the Constant Air Volume Air Conditioning System  

E-Print Network [OSTI]

The energy consumption of the constant air volume (CAV) system largely depends on the regulation strategies. Although some air conditioning systems are equipped with automatic regulation devices, others lack effective regulation strategies. To avoid...

Bai, T.; Zhang, J.; Ning, N.; Tong, K.; Wu, Y.; Wang, H.

2006-01-01T23:59:59.000Z

66

Alternate Air Delivery Systems for Hot and Humid Climates  

E-Print Network [OSTI]

Carter & Burgess first began using triple deck multi-zone units, in place of traditional VAV systems, on the Texas State Capitol restoration. Since the completion of that project design in early 1991, our firm has now used triple deck multi...

Wallace, M.

1996-01-01T23:59:59.000Z

67

Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency Vol.IV-1-3 Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency Huawei Zhu Zhejiang Urban and Rural Planning Design Institute... conditioning system has led to extensive criticism. 2. THE CHARACTERISTICS OF THE VARIABLE REFRIGERANT VOLUME AIR CONDITIONING SYSTEM AND ITS PRESENT APPLICATION ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency Vol.IV-1-3 2...

Zhu, H.

2006-01-01T23:59:59.000Z

68

System 80+{trademark} Standard Design: CESSAR design certification. Volume 18: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80+{trademark} Standard Design. This Volume 18 provides Appendix B, Probabilistic Risk Assessment.

Not Available

1990-12-21T23:59:59.000Z

69

System 80+{trademark} Standard Design: CESSAR design certification. Volume 6: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This report, Volume 6, in conjunction with Volume 7, provides a description of engineered safety features.

Not Available

1990-12-21T23:59:59.000Z

70

System 80+{trademark} Standard Design: CESSAR design certification. Volume 11: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 11 discusses Radiation Protection, Conduct of Operations, and the Initial Test Program.

Not Available

1990-12-21T23:59:59.000Z

71

System 80+{trademark} Standard Design: CESSAR design certification. Volume 8: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 8 provides a description of instrumentation and controls.

Not Available

1990-12-21T23:59:59.000Z

72

Evaluation of spatial-spectral filtering in non-paraxial volume holographic imaging systems  

E-Print Network [OSTI]

In this thesis, the properties of transmission-mode volume phase holograms as spatial-spectral filters in optical systems for microscopic medical imaging are evaluated. In experiment, the relationship between the angle of ...

Watson, Jonathan M

2008-01-01T23:59:59.000Z

73

Two-particle multichannel systems in a finite volume with arbitrary spin  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

The quantization condition for two-particle systems with arbitrary number of two-body open coupled channels, spin and masses in a finite cubic volume with either periodic or twisted boundary conditions is presented. The condition presented is in agreement with all previous studies of two-body systems in a finite volume. The result is relativistic, holds for all momenta below the three- and four-particle thresholds, and is exact up to exponential volume corrections that are governed by L/r, where L is the spatial extent of the volume and r is the range of the interactions between the particles. For hadronic systems the range of the interaction is set by the inverse of the pion mass, m?, and as a result the formalism presented is suitable for m?L>>1. Implications of the formalism for the studies of multichannel baryon-baryon systems are discussed.

Briceno, Raul A. [JLAB

2014-04-01T23:59:59.000Z

74

Two-particle multichannel systems in a finite volume with arbitrary spin  

SciTech Connect (OSTI)

The quantization condition for two-particle systems with arbitrary number of two-body open coupled channels, spin and masses in a finite cubic volume with either periodic or twisted boundary conditions is presented. The condition presented is in agreement with all previous studies of two-body systems in a finite volume. The result is relativistic, holds for all momenta below the three- and four-particle thresholds, and is exact up to exponential volume corrections that are governed by L/r, where L is the spatial extent of the volume and r is the range of the interactions between the particles. For hadronic systems the range of the interaction is set by the inverse of the pion mass, m?, and as a result the formalism presented is suitable for m?L>>1. Implications of the formalism for the studies of multichannel baryon-baryon systems are discussed.

Briceno, Raul A. [JLAB

2014-04-01T23:59:59.000Z

75

System and method for radiation dose calculation within sub-volumes of a monte carlo based particle transport grid  

DOE Patents [OSTI]

A system and method is disclosed for radiation dose calculation within sub-volumes of a particle transport grid. In a first step of the method voxel volumes enclosing a first portion of the target mass are received. A second step in the method defines dosel volumes which enclose a second portion of the target mass and overlap the first portion. A third step in the method calculates common volumes between the dosel volumes and the voxel volumes. A fourth step in the method identifies locations in the target mass of energy deposits. And, a fifth step in the method calculates radiation doses received by the target mass within the dosel volumes. A common volume calculation module inputs voxel volumes enclosing a first portion of the target mass, inputs voxel mass densities corresponding to a density of the target mass within each of the voxel volumes, defines dosel volumes which enclose a second portion of the target mass and overlap the first portion, and calculates common volumes between the dosel volumes and the voxel volumes. A dosel mass module, multiplies the common volumes by corresponding voxel mass densities to obtain incremental dosel masses, and adds the incremental dosel masses corresponding to the dosel volumes to obtain dosel masses. A radiation transport module identifies locations in the target mass of energy deposits. And, a dose calculation module, coupled to the common volume calculation module and the radiation transport module, for calculating radiation doses received by the target mass within the dosel volumes.

Bergstrom, Paul M. (Livermore, CA); Daly, Thomas P. (Livermore, CA); Moses, Edward I. (Livermore, CA); Patterson, Jr., Ralph W. (Livermore, CA); Schach von Wittenau, Alexis E. (Livermore, CA); Garrett, Dewey N. (Livermore, CA); House, Ronald K. (Tracy, CA); Hartmann-Siantar, Christine L. (Livermore, CA); Cox, Lawrence J. (Los Alamos, NM); Fujino, Donald H. (San Leandro, CA)

2000-01-01T23:59:59.000Z

76

High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems  

Broader source: Energy.gov [DOE]

Project objective: Advance the technology for well fluids lifting systems to meet the foreseeable pressure; temperature; and longevity needs of the Enhanced Geothermal Systems (EGS) industry.

77

Assessment of effectiveness of geologic isolation systems. CIRMIS data system. Volume 3. Generator routines  

SciTech Connect (OSTI)

The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (ONWI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for utilization by the hydraulic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required. The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System, a storage and retrieval system for model input and output data, including graphical interpretation and display is described. This is the third of four volumes of the description of the CIRMIS Data System.

Friedrichs, D.R.; Argo, R.S.

1980-01-01T23:59:59.000Z

78

Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring DOENA27323-1  

SciTech Connect (OSTI)

Compact maintenance free mechanical cooling systems are being developed to operate large volume germanium detectors for field applications. To accomplish this we are utilizing a newly available generation of Stirling-cycle mechanical coolers to operate the very largest volume germanium detectors with no maintenance. The user will be able to leave these systems unplugged on the shelf until needed. The flip of a switch will bring a system to life in ~ 1 hour for measurements. The maintenance-free operating lifetime of these detector systems will exceed 5 years. These features are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems for Nuclear Explosion Monitoring. The Radionuclide Aerosol Sampler/Analyzer (RASA) will greatly benefit from the availability of such detectors by eliminating the need for liquid nitrogen at RASA sites while still allowing the very largest available germanium detectors to be reliably utilized.

Hull, E.L.

2006-07-28T23:59:59.000Z

79

Hot Thermal Storage/Selective Energy System Reduces Electric Demand for Space Cooling As Well As Heating in Commercial Application  

E-Print Network [OSTI]

energy and off-peak electric resistance heating. Estimated energy and first cost savings, as compared with an all-electric VAV HVAC system, are: 30 to 50% in ductwork size and cost; 30% in fan energy; 25% in air handling equipment; 20 to 40% in utility...

Meckler, G.

1985-01-01T23:59:59.000Z

80

TPX: Contractor preliminary design review. Volume 2, PF systems engineering  

SciTech Connect (OSTI)

This system development specification covers the Poloidal Field (PF) Magnet System, WBS 14 in the Princeton Plasma Physics Laboratory TPX Program to build a tokamak fusion reactor. This specification establishes the performance, design, development and test requirements of the PF Magnet System.

Calvin, H.A. [Lawrence Livermore National Lab., CA (United States)

1995-07-28T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Evaluation of line focus solar central power systems. Volume II. Systems evaluation  

SciTech Connect (OSTI)

An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. The parabolic trough concept (BDM) was found to provide a low temperature technology alternative to the central receiver concept with promising performance and cost potential. Its continued development is recommended, with special emphasis on lower temperature (< 700/sup 0/F) applications. Finally, a variety of new promising line focus power system configurations were identified for a range of utility and industrial applications and recommendations were made on their implementation. This volume contains the detailed report. (WHK)

Not Available

1980-03-15T23:59:59.000Z

82

Preliminary characterization of abandoned septic tank systems. Volume 1  

SciTech Connect (OSTI)

This report documents the activities and findings of the Phase I Preliminary Characterization of Abandoned Septic Tank Systems. The purpose of the preliminary characterization activity was to investigate the Tiger Team abandoned septic systems (tanks and associated leachfields) for the purpose of identifying waste streams for closure at a later date. The work performed was not to fully characterize or remediate the sites. The abandoned systems potentially received wastes or effluent from buildings which could have discharged non-domestic, petroleum hydrocarbons, hazardous, radioactive and/or mixed wastes. A total of 20 sites were investigated for the preliminary characterization of identified abandoned septic systems. Of the 20 sites, 19 were located and characterized through samples collected from each tank(s) and, where applicable, associated leachfields. The abandoned septic tank systems are located in Areas 5, 12, 15, 25, and 26 on the Nevada Test Site.

NONE

1995-12-01T23:59:59.000Z

83

Case Study: The Effective Use of an Extensive Logical rule Based Data Analytics Approach in Establishing Root Cause of Performance Issues in Widespread Deployments of Unitary Space Air Conditioning Units  

E-Print Network [OSTI]

Today a significant percentage of office spaces are air conditioned using widely deployed unitary systems, either Fan Coil Units (FCU) or Variable Air Volume (VAV) boxes, to achieve high degrees of air conditioned zonal control. However establishing...

Brady, N.

2013-01-01T23:59:59.000Z

84

Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis.  

E-Print Network [OSTI]

??The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has… (more)

Kimla, John

2010-01-01T23:59:59.000Z

85

RELAP5/MOD3 code manual: Code structure, system models, and solution methods. Volume 1  

SciTech Connect (OSTI)

The RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents, and operational transients, such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling, approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I provides modeling theory and associated numerical schemes.

NONE

1995-08-01T23:59:59.000Z

86

Economic development through biomass system integration. Volumes 2--4  

SciTech Connect (OSTI)

Report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners.

DeLong, M.M.

1995-10-01T23:59:59.000Z

87

Community energy systems and the law of public utilities. Volume 20. Louisiana  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Louisiana governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities--Volume One: An overview. This report also contains a summary of a strategy described in Volume One--An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enchance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

88

Community Energy Systems and the Law of Public Utilities. Volume Twenty-four. Michigan  

SciTech Connect (OSTI)

A detailed description of the laws and programs of the State of Michigan governing the regulation of public energy facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

89

Mechanically Cooled Large-Volume Germanium Detector Systems for Neclear Explosion Monitoring DOENA27323-2  

SciTech Connect (OSTI)

Compact maintenance free mechanical cooling systems are being developed to operate large volume high-resolution gamma-ray detectors for field applications. To accomplish this we are utilizing a newly available generation of Stirling-cycle mechanical coolers to operate the very largest volume germanium detectors with no maintenance. The user will be able to leave these systems unplugged on the shelf until needed. The maintenance-free operating lifetime of these detector systems will exceed 5 years. Three important factors affect the operation of mechanically cooled germanium detectors: temperature, vacuum, and vibration. These factors will be studied in the laboratory at the most fundamental levels to insure a solid understanding of the physical limitations each factor places on a practical mechanically cooled germanium detector system. Using this knowledge, mechanically cooled germanium detector prototype systems will be designed and fabricated.

Hull, E.L.

2006-10-30T23:59:59.000Z

90

Progress in passive solar energy systems. Volume 8. Part 1  

SciTech Connect (OSTI)

This book presents the papers given at a conference sponsored by the US DOE, the Solar Energy Research Institute, SolarVision, Inc., and the Southern California Solar Energy Society. The topics considered at the conference included sizing solar energy systems for agricultural applications, a farm scale ethanol production plant, the EEC wind energy RandD program, the passive solar performance assessment of an earth-sheltered house, the ARCO 1 MW photovoltaic power plant, the performance of a dendritic web photovoltaic module, second generation point focused concentrators, linear fresnel lens concentrating photovoltaic collectors, photovoltaic conversion efficiency, amorphous silicon thin film solar cells, a photovoltaic system for a shopping center, photovoltaic power generation for the utility industry, spectral solar radiation, and the analysis of insolation data.

Hayes, J.; Andrejko, D.A.

1983-01-01T23:59:59.000Z

91

Economic development through biomass system integration: Volume 1  

SciTech Connect (OSTI)

This report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners. Chapters describe alfalfa basics, production risks, production economics, transportation and storage, processing, products, market analysis, business analysis, environmental impact, and policy issues. 69 figs., 63 tabs.

DeLong, M.M. [Northern States Power Co., Minneapolis, MN (United States)

1995-10-01T23:59:59.000Z

92

System 80+{trademark} Standard Design: CESSAR design certification. Volume 4: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This report, Volume 4, provides a description of the reactor, reactor internals, fuel assemblies, and associated design requirements.

Not Available

1990-12-21T23:59:59.000Z

93

GENII: The Hanford Environmental Radiation Dosimetry Software System: Volume 1, Conceptual representation  

SciTech Connect (OSTI)

The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). The purpose of this coupled system of computer codes is to analyze environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil. This is accomplished by calculating radiation doses to individuals or populations. GENII is described in three volumes of documentation. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. The third volume is a Code Maintenance Manual for the user who requires knowledge of code detail. It includes code logic diagrams, global dictionary, worksheets, example hand calculations, and listings of the code and its associated data libraries. 72 refs., 15 figs., 34 tabs.

Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

1988-12-01T23:59:59.000Z

94

Frontiers in Public Health Services and Systems Research Volume 1 | Number 1 Article 6  

E-Print Network [OSTI]

improvement plans. Since these activities are fundamental aspects of accreditation and health reformFrontiers in Public Health Services and Systems Research Volume 1 | Number 1 Article 6 4-17-2012 Patterns of Interaction Among Local Public Health Officials and the Adoption of Recommended Practices

Sadeh, Norman M.

95

Conversion system overview assessment. Volume III. Solar thermal/coal or biomass derived fuels  

SciTech Connect (OSTI)

The three volumes of this report cover three distinct areas of solar energy research: solar thermoelectrics, solar-wind hybrid systems, and synthetic fuels derived with solar thermal energy. Volume III deals with the conversion of synthetic fuels with solar thermal heat. The method is a hybrid combination of solar energy with either coal or biomass. A preliminary assessment of this technology is made by calculating the cost of fuel produced as a function of the cost of coal and biomass. It is shown that within the projected ranges of coal, biomass, and solar thermal costs, there are conditions when solar synthetic fuels with solar thermal heat will become cost-competitive.

Copeland, R. J.

1980-02-01T23:59:59.000Z

96

Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1  

SciTech Connect (OSTI)

The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.

NONE

1996-02-26T23:59:59.000Z

97

Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system. Volume 1  

SciTech Connect (OSTI)

The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data.

Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

1993-03-01T23:59:59.000Z

98

Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring  

SciTech Connect (OSTI)

Compact maintenance free mechanical cooling systems are being developed to operate large volume (~570 cm3, ~3 kg, 140% or larger) germanium detectors for field applications. We are using a new generation of Stirling-cycle mechanical coolers for operating the very largest volume germanium detectors with absolutely no maintenance or liquid nitrogen requirements. The user will be able to leave these systems unplugged on the shelf until needed. The flip of a switch will bring a system to life in ~1 hour for measurements. The maintenance-free operating lifetime of these detector systems will exceed five years. These features are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems for Nuclear Explosion Monitoring (NEM). The Radionuclide Aerosol Sampler/Analyzer (RASA) will greatly benefit from the availability of such detectors by eliminating the need for liquid nitrogen at RASA sites while still allowing the very largest available germanium detectors to be utilized. These mechanically cooled germanium detector systems being developed here will provide the largest, most sensitive detectors possible for use with the RASA. To provide such systems, the appropriate technical fundamentals are being researched. Mechanical cooling of germanium detectors has historically been a difficult endeavor. The success or failure of mechanically cooled germanium detectors stems from three main technical issues: temperature, vacuum, and vibration. These factors affect one another. There is a particularly crucial relationship between vacuum and temperature. These factors will be experimentally studied both separately and together to insure a solid understanding of the physical limitations each factor places on a practical mechanically cooled germanium detector system for field use. Using this knowledge, a series of mechanically cooled germanium detector prototype systems are being designed and fabricated. Our collaborators at Pacific Northwest National Laboratory (PNNL) will evaluate these detector systems on the bench top and eventually in RASA systems to insure reliable and practical operation.

Hull, Ethan L.; Pehl, Richard H.; Lathrop, James R.; Martin, Gregory N.; Mashburn, R. B.; Miley, Harry S.; Aalseth, Craig E.; Hossbach, Todd W.; Bowyer, Ted W.

2006-09-21T23:59:59.000Z

99

Utility FGD survey: January--December 1989. Volume 1, Categorical summaries of FGD systems  

SciTech Connect (OSTI)

This is Volume 1 of the Utility flue gas desulfurization (FGD) Survey report, which is generated by a computerized data base management system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems. It summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. The development status (operational, under construction, or in the planning stages), system supplier, process, waste disposal practice, and regulatory class are tabulated alphabetically by utility company.

Hance, S.L.; McKibben, R.S.; Jones, F.M.

1992-03-01T23:59:59.000Z

100

Control Volume Analysis, Entropy Balance and the Entropy Production in Flow Systems  

E-Print Network [OSTI]

This chapter concerns "control volume analysis", the standard engineering tool for the analysis of flow systems, and its application to entropy balance calculations. Firstly, the principles of control volume analysis are enunciated and applied to flows of conserved quantities (e.g. mass, momentum, energy) through a control volume, giving integral (Reynolds transport theorem) and differential forms of the conservation equations. Several definitions of steady state are discussed. The concept of "entropy" is then established using Jaynes' maximum entropy method, both in general and in equilibrium thermodynamics. The thermodynamic entropy then gives the "entropy production" concept. Equations for the entropy production are then derived for simple, integral and infinitesimal flow systems. Some technical aspects are examined, including discrete and continuum representations of volume elements, the effect of radiation, and the analysis of systems subdivided into compartments. A Reynolds decomposition of the entropy production equation then reveals an "entropy production closure problem" in fluctuating dissipative systems: even at steady state, the entropy production based on mean flow rates and gradients is not necessarily in balance with the outward entropy fluxes based on mean quantities. Finally, a direct analysis of an infinitesimal element by Jaynes' maximum entropy method yields a theoretical framework with which to predict the steady state of a flow system. This is cast in terms of a "minimum flux potential" principle, which reduces, in different circumstances, to maximum or minimum entropy production (MaxEP or MinEP) principles. It is hoped that this chapter inspires others to attain a deeper understanding and higher technical rigour in the calculation and extremisation of the entropy production in flow systems of all types.

Robert K. Niven; Bernd R. Noack

2014-07-21T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

PSU CBEI: VOLTTRON Compatible and Cost-Effective Fault Diagnostic Solutions for AHU-VAV and AHU-CAV Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L d F SSalesOE0000652 Srivastava, WSUEnergy 72Energy 9 - InPSU

102

Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002  

E-Print Network [OSTI]

(CAVRH), and variable volume with reheat (VAVRH), four pipe fan coil unit (FC), four pipe induction unit (FI), and a single zone air conditioning system (SZ). These calculations are presented in spreadsheets that include a running commentary so...

Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

2001-01-01T23:59:59.000Z

103

Deep Drilling Basic Research: Volume 5 - System Evaluations. Final Report, November 1988--August 1990  

SciTech Connect (OSTI)

This project is aimed at decreasing the costs and increasing the efficiency of drilling gas wells in excess of 15,000 feet. This volume presents a summary of an evaluation of various drilling techniques. Drilling solutions were compared quantitatively against typical penetration rates derived from conventional systems. A qualitative analysis measured the impact of a proposed system on the drilling industry. The evaluations determined that the best candidates f o r improving the speed and efficiency of drilling deep gas wells include: PDC/TSD bits, slim-hole drilling, roller-cone bits, downhole motors, top-driven systems, and coiled-tubing drilling.

None

1990-06-01T23:59:59.000Z

104

Evaluation of line focus solar central power systems. Volume I. Executive summary  

SciTech Connect (OSTI)

An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. This volume is an executive summary. (WHK)

Not Available

1980-03-15T23:59:59.000Z

105

Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems  

E-Print Network [OSTI]

SDCVP 67.380 $153.200 $41.800 $195.000 $2.89 measured energy consumption for each building. The horizontal axis is the ambient temperature. The venical axis is the average daily energy consumption in MMBtulhr. Figure 5 compares the predicted...REDUCING BUILDING ENERGY COSTS USING OPTIMIZED OPERATION STRATEGIES FOR CONSTANT VOLUME AIR HANDLING SYSTEMS Mingsheng Liu, her Atha, Agarni Reddy Ed White David Claridge and Jeff Haberl Department of Physical Plant Texas A&M University...

Liu, M.; Athar, A.; Reddy, A.; Claridge, D. E.; Haberl, J. S.; White, E.

1994-01-01T23:59:59.000Z

106

Hot-gas cleanup system model development. Volume I. Final report  

SciTech Connect (OSTI)

This two-volume report summarizes the state of the art in performance modeling of advanced high-temperature, high-pressure (HTHP) gas cleanup devices. Volume I contains the culmination of the research effort carried over the past 12 months and is a summary of research achievements. Volume II is the user's manual for the computer programs developed under the present research project. In this volume, Section 2 presents background information on pressurized, fluidized-bed combustion concepts, a description of the role of the advanced gas cleanup systems, and a list of advanced gas cleanup systems that are currently in development under DOE sponsorship. Section 3 describes the methodology for the software architecture that forms the basis of the well-disciplined and structured computer programs developed under the present project. Section 4 reviews the fundamental theories that are important in analyzing the cleanup performance of HTHP gas filters. Section 5 discusses the effect of alkali agents in HTHP gas cleanup. Section 6 evaluates the advanced HTHP gas cleanup models based on their mathematical integrity, availability of supporting data, and the likelihood of commercialization. As a result of the evaluation procedure detailed in Section 6, five performance models were chosen to be incorporated into the overall system simulation code, ASPEN. These five models (the electrocyclone, ceramic bag filter, moving granular bed filter, electrostatic granular bed filter, and electrostatic precipitator) are described in Section 7. The method of cost projection for these five models is discussed in Section 8. The supporting data and validation of the computer codes are presented in Section 9, and finally the conclusions and recommendations for the HTHP gas cleanup system model development are given in Section 10. 72 references, 19 figures, 25 tables.

Ushimaru, K.; Bennett, A.; Bekowies, P.J.

1982-11-01T23:59:59.000Z

107

Preliminary environmental assessment for the Satellite Power System (SPS). Revision 1. Volume 2. Detailed assessment  

SciTech Connect (OSTI)

The Department of Energy (DOE) is considering several options for generating electrical power to meet future energy needs. The satellite power system (SPS), one of these options, would collect solar energy through a system of satellites in space and transfer this energy to earth. A reference system has been described that would convert the energy to microwaves and transmit the microwave energy via directive antennas to large receiving/rectifying antennas (rectennas) located on the earth. At the rectennas, the microwave energy would be converted into electricity. The potential environmental impacts of constructing and operating the satellite power system are being assessed as a part of the Department of Energy's SPS Concept Development and Evaluation Program. This report is Revision I of the Preliminary Environmental Assessment for the Satellite Power System published in October 1978. It refines and extends the 1978 assessment and provides a basis for a 1980 revision that will guide and support DOE recommendations regarding future SPS development. This is Volume 2 of two volumes. It contains the technical detail suitable for peer review and integrates information appearing in documents referenced herein. The key environmental issues associated with the SPS concern human health and safety, ecosystems, climate, and electromagnetic systems interactions. In order to address these issues in an organized manner, five tasks are reported: (I) microwave-radiation health and ecological effects; (II) nonmicrowave health and ecological effectss; (III) atmospheric effects; (IV) effects on communication systems due to ionospheric disturbance; and (V) electromagnetic compatibility. (WHK)

Not Available

1980-01-01T23:59:59.000Z

108

Deep Drilling Basic Research: Volume 4 - System Description. Final Report, November 1988--August 1990  

SciTech Connect (OSTI)

The first section of this Volume will discuss the ''Conventional Drilling System''. Today's complex arrangement of numerous interacting systems has slowly evolved from the very simple cable tool rigs used in the late 1800s. Improvements to the conventional drilling rig have varied in size and impact over the years, but the majority of them have been evolutionary modifications. Each individual change or improvement of this type does not have significant impact on drilling efficiency and economics. However, the change is almost certain to succeed, and over time--as the number of evolutionary changes to the system begin to add up--improvements in efficiency and economics can be seen. Some modifications, defined and described in this Volume as Advanced Modifications, have more than just an evolutionary effect on the conventional drilling system. Although the distinction is subtle, there are several examples of incorporated advancements that have had significantly more impact on drilling procedures than would a truly evolutionary improvement. An example of an advanced modification occurred in the late 1970s with the introduction of Polycrystalline Diamond Compact (PDC) drill bits. PDC bits resulted in a fundamental advancement in drilling procedures that could not have been accomplished by an evolutionary improvement in materials metallurgy, for example. The last drilling techniques discussed in this Volume are the ''Novel Drilling Systems''. The extent to which some of these systems have been developed varies from actually being tested in the field, to being no more than a theoretical concept. However, they all have one thing in common--their methods of rock destruction are fundamentally different from conventional drilling techniques. When a novel drilling system is introduced, it is a revolutionary modification of accepted drilling procedures and will completely replace current techniques. The most prominent example of a revolutionary modification in recent history was the complete displacement of cable tool rigs by rotary drilling rigs in the late 1920s.

Anderson, E.E.; Maurer, W.C.; Hood, M.; Cooper, G.; Cook, N.

1990-06-01T23:59:59.000Z

109

Utility FGD survey, January--December 1989. Volume 2, Design performance data for operating FGD systems: Part 2  

SciTech Connect (OSTI)

This is Volume 2 part 2, of the Utility flue gas desulfurization (FGD) Survey report, which is generated by a computerized data base management system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems. It summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. This volume particularly contains basic design and performance data.

Hance, S.L.; McKibben, R.S.; Jones, F.M. [IT Corp., Cincinnati, OH (United States)] [IT Corp., Cincinnati, OH (United States)

1992-03-01T23:59:59.000Z

110

Community Energy Systems and the Law of Public Utilities. Volume Three. Alabama  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Alabama governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

111

Community Energy Systems and the Law of Public Utilities. Volume Ten. Delaware  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Delaware governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

112

Community Energy Systems and the Law of Public Utilities. Volume Thirty-three. New Mexico  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of New Mexico governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

113

Community Energy Systems and the Law of Public Utilities. Volume Six. Arkansas  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Arkansas governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

114

Community Energy Systems and the Law of Public Utilities. Volume Nine. Connecticut  

SciTech Connect (OSTI)

A detailed description of the laws and programs of the State of Connecticut governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

115

Community Energy Systems and the Law of Public Utilities. Volume Thirty-one. New Hampshire  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of New Hampshire governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One. An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

116

Community Energy Systems and the Law of Public Utilities. Volume Fifty-one. Wisconsin  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Wisconsin governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

117

Community Energy Systems and the Law of Public Utilities. Volume Thirty. Nevada  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Nevada governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

118

Community Energy Systems and the Law of Public Utilities. Volume Four. Alaska  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Alaska governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

119

Community Energy Systems and the Law of Public Utilities. Volume Forty-four. Tennessee  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Tennessee governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

120

Community Energy Systems and the Law of Public Utilities. Volume Forty-three. South Dakota  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of South Dakota governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Community Energy Systems and the Law of Public Utilities. Volume Forty-nine. Washington  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Washington governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

122

Community Energy Systems and the Law of Public Utilities. Volume Forty-eight. Virginia  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Virginia governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

123

Community Energy Systems and the Law of Public Utilities. Volume Eighteen. Kansas  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Kansas governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

124

Community Energy Systems and the Law of Public Utilities. Volume Nineteen. Kentucky  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Kentucky governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

125

Community Energy Systems and the Law of Public Utilities. Volume Thirty-two. New Jersey  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of New Jersey governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

126

Community Energy Systems and the Law of Public Utilities. Volume Forty. Pennsylvania  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Pennsylvania governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

127

Community Energy Systems and the Law of Public Utilities. Volume Five. Arizona  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Arizona governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

128

Community Energy Systems and the Law of Public Utilities. Volume Twelve. Georgia  

SciTech Connect (OSTI)

A detailed description of the laws and programs of the State of Georgia governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

129

Community Energy Systems and the Law of Public Utilities. Volume Thirty-nine. Oregon  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Oregon governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

130

Community Energy Systems and the Law of Public Utilities. Volume Twenty-five. Minnesota  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Minnesota governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

131

Community Energy Systems and the Law of Public Utilities. Volume Eleven. Florida  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Florida governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

132

Community Energy Systems and the Law of Public Utilities. Volume Fifteen. Illinois  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Illinois governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

133

Community Energy Systems and the Law of Public Utilities. Volume Twenty-two. Maryland  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Maryland governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

134

Community Energy Systems and the Law of Public Utilities. Volume Eight. Colorado  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Colorado governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

135

Community Energy Systems and the Law of Public Utilities. Volume Thirty-seven. Ohio  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Ohio governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

136

Community Energy Systems and the Law of Public Utilities. Volume Two. Federal  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the Federal government governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

137

Community Energy Systems and the Law of Public Utilities. Volume Forty-two. South Carolina  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of South Carolina governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

138

Community Energy Systems and the Law of Public Utilities. Volume Thirty-six. North Dakota  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of North Dakota governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

139

Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?  

E-Print Network [OSTI]

The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy...

Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

2002-01-01T23:59:59.000Z

140

Model documentation: Natural Gas Transmission and Distribution Model of the National Energy Modeling System; Volume 1  

SciTech Connect (OSTI)

The Natural Gas Transmission and Distribution Model (NGTDM) is a component of the National Energy Modeling System (NEMS) used to represent the domestic natural gas transmission and distribution system. NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the Energy Information Administration (EIA) and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. This report documents the archived version of NGTDM that was used to produce the natural gas forecasts used in support of the Annual Energy Outlook 1994, DOE/EIA-0383(94). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. It is intended to fulfill the legal obligation of the EIA to provide adequate documentation in support of its models (Public Law 94-385, Section 57.b.2). This report represents Volume 1 of a two-volume set. (Volume 2 will report on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.) Subsequent chapters of this report provide: (1) an overview of the NGTDM (Chapter 2); (2) a description of the interface between the National Energy Modeling System (NEMS) and the NGTDM (Chapter 3); (3) an overview of the solution methodology of the NGTDM (Chapter 4); (4) the solution methodology for the Annual Flow Module (Chapter 5); (5) the solution methodology for the Distributor Tariff Module (Chapter 6); (6) the solution methodology for the Capacity Expansion Module (Chapter 7); (7) the solution methodology for the Pipeline Tariff Module (Chapter 8); and (8) a description of model assumptions, inputs, and outputs (Chapter 9).

NONE

1994-02-24T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Precursor systems analyses of automated highway systems: Commercial vehicle and transit ahs analysis. Volume 6. Final report, September 1993-February 1995  

SciTech Connect (OSTI)

This document is the final report of the Automated Highway System (AHS). The activities of Commercial Vehicle and Transit AHS Analysis are reported on in this document. This document type is resource materials. This volume is the six in a series. There are nine other volumes in the series.

Bottiger, F.; Chemnitz, H.D.; Doorman, J.; Franke, U.; Zimmerman, T.

1995-03-01T23:59:59.000Z

142

Marine Tactical Command and Control System (MTACCS), Field Development System-1 (FDS-1) assessment: Volume 2  

SciTech Connect (OSTI)

The following appendices contain the detailed analysis data for the questionnaires and various FDS-1 after action reports submitted to the Marine Corps Systems Command (MARCORSYSCOM) Marine Tactical Command and Control System (MTACCS) Systems' Engineer.

Avery, L W; Hunt, S T; Savage, S F [Pacific Northwest Lab., Richland, WA (United States); McLaughlin, P D; Shepard, A P; Worl, J C [Battelle Seattle Research Center, Seattle, WA (United States)

1992-04-01T23:59:59.000Z

143

Transportation Sector Model of the National Energy Modeling System. Volume 2 -- Appendices: Part 1  

SciTech Connect (OSTI)

This volume contains input data and parameters used in the model of the transportation sector of the National Energy Modeling System. The list of Transportation Sector Model variables includes parameters for the following: Light duty vehicle modules (fuel economy, regional sales, alternative fuel vehicles); Light duty vehicle stock modules; Light duty vehicle fleet module; Air travel module (demand model and fleet efficiency model); Freight transport module; Miscellaneous energy demand module; and Transportation emissions module. Also included in these appendices are: Light duty vehicle market classes; Maximum light duty vehicle market penetration parameters; Aircraft fleet efficiency model adjustment factors; and List of expected aircraft technology improvements.

NONE

1998-01-01T23:59:59.000Z

144

Technical and economic assessment of fluidized bed augmented compressed air energy storage system. Volume III. Preconceptual design  

SciTech Connect (OSTI)

A technical and economic assessment of fluidized bed combustion augmented compressed air energy storage systems is presented. The results of this assessment effort are presented in three volumes. Volume III - Preconceptual Design contains the system analysis which led to the identification of a preferred component configuration for a fluidized bed combustion augmented compressed air energy storage system, the results of the effort which transformed the preferred configuration into preconceptual power plant design, and an introductory evaluation of the performance of the power plant system during part-load operation and while load following.

Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

1981-09-01T23:59:59.000Z

145

Continuous Commissioning® of a Single Fan Dual Duct System in an Office Building  

E-Print Network [OSTI]

boxes are independent boxes, which are operated in CAV modes. The building continuous commissioning was started on June 2004. It is being commissioned following the approaches used by the Energy Systems Laboratory at Nebraska University, which... in this case include installing VFD on the supply fan and return fan, updating all terminal boxes from CAV modes into VAV modes, resetting duct static pressure and supply air temperature, optimizing outside air intake and installing VFDs on chiller...

Dong, D.; Liu, M.

2005-01-01T23:59:59.000Z

146

to appear in the International Journal of Imaging Systems and Technology, special issue on 3D Imaging Real-Time Volume Rendering  

E-Print Network [OSTI]

to appear in the International Journal of Imaging Systems and Technology, special issue on 3D volume visualization hardware comes a new challenge: effectively harnessing the visu- alization power- gorithms such as perspective rendering, overlapping volumes, and geometry mixing within volumes. We examine

Chen, Baoquan

147

to appear in the International Journal of Imaging Systems and Technology, special issue on 3D Imaging RealTime Volume Rendering  

E-Print Network [OSTI]

to appear in the International Journal of Imaging Systems and Technology, special issue on 3D­powered, commodity volume visualization hardware comes a new challenge: effectively harnessing the visu­ alization­ gorithms such as perspective rendering, overlapping volumes, and geometry mixing within volumes. We examine

Chen, Baoquan

148

Hanford Environmental Information System (HEIS). Volume 1, User`s guide  

SciTech Connect (OSTI)

The Hanford Environmental Information System (HEIS) is a consolidated set of automated resources that effectively manage the data gathered during environmental monitoring and restoration of the Hanford Site. HEIS includes an integrated database that provides consistent and current data to all users and promotes sharing of data by the entire user community. HEIS is an information system with an inclusive database. Although the database is the nucleus of the system, HEIS also provides user access software: query-by-form data entry, extraction, and browsing facilities; menu-driven reporting facilities; an ad hoc query facility; and a geographic information system (GIS). These features, with the exception of the GIS, are described in this manual set. Because HEIS contains data from the entire Hanford Site, many varieties of data are included and have.been divided into subject areas. Related subject areas comprise several volumes of the manual set. The manual set includes a data dictionary that lists all of the fields in the HEIS database, with their definitions and a cross reference of their locations in the database; definitions of data qualifiers for analytical results; and a mapping between the HEIS software functions and the keyboard keys for each of the supported terminals or terminal emulators.

Not Available

1994-01-14T23:59:59.000Z

149

Proceedings of the seventh annual gasification and gas stream cleanup systems contractors review meeting: Volume 2  

SciTech Connect (OSTI)

On June 16 through 19, 1987, METC sponsored the Seventh Annual Gasification and Gas Stream Cleanup Systems Contractors Review Meeting which was held at the Sheraton Lakeview Conference Center in Morgantown, West Virginia. The primary purpose of the meeting was threefold: to review the technical progress and current status of the gasification and gas stream cleanup projects sponsored by the Department of Energy; to foster technology exchange among participating researchers and other technical communities; to facilitate interactive dialogues which would identify research needs that would make coal-based gasification systems more attractive economically and environmentally. More than 310 representatives of Government, academia, industry, and foreign energy research organizations attended the 4-day meeting. Fifty-three papers and thirty poster dsplays were presented summarizing recent developments in the gasification and gas stream cleanup programs. Volume II covers papers presented at sessions 5 and 6 on system for the production of synthesis gas, and on system for the production of power. All papers have been processed for inclusion in the Energy Data Base.

Ghate, M.R.; Markel, K.E. Jr.; Jarr, L.A.; Bossart, S.J. (eds.)

1987-08-01T23:59:59.000Z

150

Impact Factors for Microinvasion in Intrahepatic Cholangiocarcinoma: A Possible System for Defining Clinical Target Volume  

SciTech Connect (OSTI)

Purpose: To quantify microscopic invasion of intrahepatic cholangiocarcinoma (IHC) into nontumor tissue and define the gross tumor volume (GTV)-to-clinical target volume (CTV) expansion necessary for radiotherapy. Methods and Materials: One-hundred IHC patients undergoing radical resection from January 2004 to July 2008 were enrolled in this study. Pathologic and clinical data including maximum tumor diameter, tumor boundary type, TNM stage, histologic grade, tumor markers, and liver enzymes were reviewed. The distance of microinvasion from the tumor boundary was measured by microscopy. The contraction coefficient for tumor measurements in radiographs and slide-mounted tissue was calculated. SPSS15.0 was used for statistical analysis. Results: Sixty-five patients (65%) exhibited tumor microinvasions. Microinvasions ranged from 0.4-8 mm, with 96% of patients having a microinvasion distance {<=}6 mm measured on slide. The radiograph-to-slide contraction coefficient was 82.1%. The degree of microinvasion was correlated with tumor boundary type, TNM stage, histologic grade, and serum levels of carbohydrate antigen 19-9, alanine aminotransferase, aspartate aminotransferase, {gamma}-glutamyltransferase and alkaline phosphatase. To define CTV accurately, we devised a scoring system based on combination of these factors. According to this system, a score {<=}1.5 is associated with 96.1% sensitivity in detecting patients with a microextension {<=}4.9 mm in radiographs, whereas a score {>=}2 has a 95.1% sensitivity in detecting microextension {<=}7.9 mm measured on radiograph. Conclusions: Patients with a score {<=}1.5 and {>=}2 require a radiographic GTV-to-CTV expansions of 4.9 and 7.9 mm, respectively, to encompass >95% of microinvasions.

Bi Aihong [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, Shanghai (China); Zeng Zhaochong, E-mail: zeng.zhaochong@zs-hospital.sh.c [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, Shanghai (China); Ji Yuan; Zeng Haiying; Xu Chen [Department of Pathology, Zhongshan Hospital, Fudan University, Shanghai (China); Tang Zhaoyou; Fan Jia; Zhou Jian [Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai (China); Zeng Mengsu [Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai (China); Tan Yunshan [Department of Pathology, Zhongshan Hospital, Fudan University, Shanghai (China)

2010-12-01T23:59:59.000Z

151

Effect of aging on the PWR Chemical and Volume Control System  

SciTech Connect (OSTI)

The PWR Chemical and Volume Control System (CVCS) is designed to provide both safety and non-safety related functions. During normal plant operation it is used to control reactor coolant chemistry, and letdown and charging flow. In many plants, the charging pumps also provide high pressure injection, emergency boration, and RCP seal injection in emergency situations. This study examines the design, materials, maintenance, operation and actual degradation experiences of the system and main sub-components to assess the potential for age degradation. A detailed review of the Nuclear Plant Reliability Data System (NPRDS) and Licensee Event Report (LER) databases for the 1988--1991 time period, together with a review of industry and NRC experience and research, indicate that age-related degradations and failures have occurred. These failures had significant effects on plant operation, including reactivity excursions, and pressurizer level transients. The majority of these component failures resulted in leakage of reactor coolant outside the containment. A representative plant of each PWR design (W, CE, and B and W) was visited to obtain specific information on system inspection, surveillance, monitoring, and inspection practices. The results of these visits indicate that adequate system maintenance and inspection is being performed. In some instances, the frequencies of inspection were increase in response to repeated failure events. A parametric study was performed to assess the effect of system aging on Core Damage Frequency (CDF). This study showed that as motor-operated valve (MOV) operating failures increased, the contribution of the High Pressure Injection to CDF also increased.

Grove, E.J.; Travis, R.J.; Aggarwal, S.K. [Brookhaven National Lab., Upton, NY (United States)

1995-06-01T23:59:59.000Z

152

Brawley 10 MW Geothermal Plant Plant Manual for Southern Californa Edison Company and Union Oil Company of California. Volume I. Systems Descriptions  

SciTech Connect (OSTI)

This volume covers Systems Descriptions. It presents each system of the facility and discusses basic features. Brief discussion of each piece of major equipment in system and design conditions.

None

1980-11-28T23:59:59.000Z

153

Proceedings of the seventh annual gasification and gas stream cleanup systems contractors review meeting: Volume 1  

SciTech Connect (OSTI)

On June 16 through 19, 1987, METC sponsored the Seventh Annual Gasification and Gas Stream Cleanup Systems Contractors Review Meeting which was held at the Sheraton Lakeview Conference Center in Morgantown, West Virginia. The primary purpose of the meeting was threefold: to review the technical progress and current status of the gasification and gas stream cleanup projects sponsored by the Department of Energy; to foster technology exchange among participating researchers and other technical communities; to facilitate interactive dialogues which would identify research needs that would make coal-based gasification systems more attractive economically and environmentally. More than 310 representatives of Government, academia, industry, and foreign energy research organizations attended the 4-day meeting. Fifty-three papers and thirty poster displays were presented summarizing recent developments in the gasification and gas stream cleanup programs. Volume I covers information presented at sessions 1 through 4 on systems for the production of Co-products and industrial fuel gas, environmental projects, and components and materials. Individual papers have been processed for the Energy Data Base.

Ghate, M.R.; Markel, K.E. Jr.; Jarr, L.A.; Bossart, S.J. (eds.)

1987-08-01T23:59:59.000Z

154

SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Control modules -- Volume 1, Revision 4  

SciTech Connect (OSTI)

SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3 for the documentation of the data libraries and subroutine libraries.

Landers, N.F.; Petrie, L.M.; Knight, J.R. [Oak Ridge National Lab., TN (United States)] [and others

1995-04-01T23:59:59.000Z

155

SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Miscellaneous -- Volume 3, Revision 4  

SciTech Connect (OSTI)

SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice; (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System developments has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3--for the data libraries and subroutine libraries.

Petrie, L.M.; Jordon, W.C. [Oak Ridge National Lab., TN (United States); Edwards, A.L. [Oak Ridge National Lab., TN (United States)]|[Lawrence Livermore National Lab., CA (United States)] [and others

1995-04-01T23:59:59.000Z

156

Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume II. Proliferation resistance  

SciTech Connect (OSTI)

The purpose of this volume is limited to an assessment of the relative effects that particular choices of nuclear-power systems, for whatever reasons, may have on the possible spread of nuclear-weapons capabilities. This volume addresses the concern that non-nuclear-weapons states may be able to initiate efforts to acquire or to improve nuclear-weapons capabilities through civilian nuclear-power programs; it also addresses the concern that subnational groups may obtain and abuse the nuclear materials or facilities of such programs, whether in nuclear-weapons states (NWS's) or nonnuclear-weapons states (NNW's). Accordingly, this volume emphasizes one important factor in such decisions, the resistance of nuclear-power systems to the proliferation of nuclear-weapons capabilities.

Not Available

1980-06-01T23:59:59.000Z

157

Medical Physics, Volume 11, No. 3 1984 , Pages 303310 A photodiode array x-ray imaging system for digital  

E-Print Network [OSTI]

Medical Physics, Volume 11, No. 3 1984 , Pages 303­310 A photodiode array x-ray imaging system, self-scanning, photodiode array Reticon RL 1024S optically coupled to an x-ray image intensifier tube, SPATIAL RESOLUTION, PHOTODIODES, BLOOD VESSELS, BIOMEDICAL RADIOGRAPHY #12;

Cunningham, Ian

158

GENII: The Hanford Environmental Radiation Dosimetry Software System: Volume 2, Users' manual: Hanford Environmental Dosimetry Upgrade Project  

SciTech Connect (OSTI)

The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). The purpose of this coupled system of computer codes is to analyze environmental contamination of, air, water, or soil. This is accomplished by calculating radiation doses to individuals or populations. GENII is described in three volumes of documentation. This second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. The first volume describes the theoretical considerations of the system. The third volume is a Code Maintenance Manual for the user who requires knowledge of code detail. It includes logic diagrams, global dictionary, worksheets, example hand calculations, and listings of the code and its associated data libraries. 27 refs., 17 figs., 23 tabs.

Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

1988-11-01T23:59:59.000Z

159

GENII (Generation II): The Hanford Environmental Radiation Dosimetry Software System: Volume 3, Code maintenance manual: Hanford Environmental Dosimetry Upgrade Project  

SciTech Connect (OSTI)

The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). This coupled system of computer codes is intended for analysis of environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil, on through the calculation of radiation doses to individuals or populations. GENII is described in three volumes of documentation. This volume is a Code Maintenance Manual for the serious user, including code logic diagrams, global dictionary, worksheets to assist with hand calculations, and listings of the code and its associated data libraries. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. 7 figs., 5 tabs.

Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

1988-09-01T23:59:59.000Z

160

Modeling water uptake by a root system growing in a fixed soil volume  

E-Print Network [OSTI]

The water uptake by roots of plants is examined for an ideal situation, with an approximation that resembles plants growing in pots, meaning that the total soil volume is fixed. We propose a coupled water uptake-root growth model. A one-dimensional model for water flux and water uptake by a root system growing uniformly distributed in the soil is presented, and the Van Genuchten model for the transport of water in soil is used. The governing equations are represented by a moving boundary model for which the root length, as a function of time, is prescribed. The solution of the model is obtained by front-fixing and finite element methods. Model predictions for water uptake by a same plant growing in loam, silt and clay soils are obtained and compared. A sensitivity analysis to determine relative effects on water uptake when system parameters are changed is also presented and shows that the model and numerical method proposed are more sensitive to the root growth rate than to the rest of the parameters. This se...

Albrieu, J L Blengino; Tarzia, D A

2015-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Advanced systems demonstration for utilization of biomass as an energy source. Volume II. Technical specifications  

SciTech Connect (OSTI)

This volume contains all of the technical specifications relating to materials and construction of the biomass cogeneration facility in the state of Maine. (DMC)

None

1980-10-01T23:59:59.000Z

162

Assessment of Energy Storage Alternatives in the Puget Sound Energy System Volume 2: Energy Storage Evaluation Tool  

SciTech Connect (OSTI)

This volume presents the battery storage evaluation tool developed at Pacific Northwest National Laboratory (PNNL), which is used to evaluate benefits of battery storage for multiple grid applications, including energy arbitrage, balancing service, capacity value, distribution system equipment deferral, and outage mitigation. This tool is based on the optimal control strategies to capture multiple services from a single energy storage device. In this control strategy, at each hour, a look-ahead optimization is first formulated and solved to determine battery base operating point. The minute by minute simulation is then performed to simulate the actual battery operation. This volume provide background and manual for this evaluation tool.

Wu, Di; Jin, Chunlian; Balducci, Patrick J.; Kintner-Meyer, Michael CW

2013-12-01T23:59:59.000Z

163

Home energy rating system building energy simulation test (HERS BESTEST). Volume 2, Tier 1 and Tier 2 tests reference results  

SciTech Connect (OSTI)

The Home Energy Rating System (HERS) Building Energy Simulation Test (BESTEST) is a method for evaluating the credibility of software used by HERS to model energy use in buildings. The method provides the technical foundation for ''certification of the technical accuracy of building energy analysis tools used to determine energy efficiency ratings,'' as called for in the Energy Policy Act of 1992 (Title I, Subtitle A, Section 102, Title II, Part 6, Section 271). Certification is accomplished with a uniform set of test cases that Facilitate the comparison of a software tool with several of the best public-domain, state-of-the-art building energy simulation programs available in the United States. The HERS BESTEST work is divided into two volumes. Volume 1 contains the test case specifications and is a user's manual for anyone wishing to test a computer program. Volume 2 contains the reference results and suggestions for accrediting agencies on how to use and interpret the results.

Judkoff, R.; Neymark, J.

1995-11-01T23:59:59.000Z

164

Finite Volume Based Computer Program for Ground Source Heat Pump System  

SciTech Connect (OSTI)

This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The price paid for the three-dimensional detail is the large computational times required with GEO3D. The computational times required for GEO2D are reasonable, a few minutes for a 20 year simulation. For a similar simulation, GEO3D takes days of computational time. Because of the small simulation times with GEO2D, a number of attractive features have been added to it. GEO2D has a user friendly interface where inputs and outputs are all handled with GUI (graphical user interface) screens. These GUI screens make the program exceptionally easy to use. To make the program even easier to use a number of standard input options for the most common GSHP situations are provided to the user. For the expert user, the option still exists to enter their own detailed information. To further help designers and GSHP customers make decisions about a GSHP heating and cooling system, cost estimates are made by the program. These cost estimates include a payback period graph to show the user where their GSHP system pays for itself. These GSHP simulation tools should be a benefit to the advancement of GSHP systems.

Menart, James A. [Wright State University

2013-02-22T23:59:59.000Z

165

Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems  

SciTech Connect (OSTI)

This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ���¢��������Finite Volume Based Computer Program for Ground Source Heat Pump Systems.���¢������� The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The price paid for the three-dimensional detail is the large computational times required with GEO3D. The computational times required for GEO2D are reasonable, a few minutes for a 20 year simulation. For a similar simulation, GEO3D takes days of computational time. Because of the small simulation times with GEO2D, a number of attractive features have been added to it. GEO2D has a user friendly interface where inputs and outputs are all handled with GUI (graphical user interface) screens. These GUI screens make the program exceptionally easy to use. To make the program even easier to use a number of standard input options for the most common GSHP situations are provided to the user. For the expert user, the option still exists to enter their own detailed information. To further help designers and GSHP customers make decisions about a GSHP heating and cooling system, cost estimates are made by the program. These cost estimates include a payback period graph to show the user where their GSHP system pays for itself. These GSHP simulation tools should be a benefit to the advancement of GSHP system

James A Menart, Professor

2013-02-22T23:59:59.000Z

166

Systems Description; Sperry Low Temperature Geothermal Conversion System - Phase I and Phase II; Final Report, Volume III  

SciTech Connect (OSTI)

This Volume should be considered the introductory volume to the series of six volumes even though numbered out of sequence. Volumes I and II were completed first and released in 1981 while a staff member was available to do the work. Volumes III through VI are being written and released some two years later as DOE funding became available for the purpose. They are as complete as possible considering that almost all the people involved in the program are now unavailable. This Volume III is an overview of the entire program, and many of the items presented herein briefly will be found in expanded form in one of the other five volumes. It will be noticed that assumptions and parameters such as well flow, well temperature, wet bulb temperatures, etc., involved in the several different performance calculations in the volume vary somewhat. These calculations were made at different times for different purposes and no attempt has been made to bring them into exact agreement.

Matthews, Hugh B.

1982-01-01T23:59:59.000Z

167

Lean Implementation Considerations in Factory Operations of Low Volume/High Complexity Production Systems  

E-Print Network [OSTI]

The researchers of the Lean Aircraft Initiative developed a hypothesized lean implementation model seeking to provide its members guidance on implementing lean transitions in factory operations of low volume/high complexity ...

Shields, Thomas J.

168

Guidelines for the verification and validation of expert system software and conventional software: Project summary. Volume 1  

SciTech Connect (OSTI)

This eight-volume report presents guidelines for performing verification and validation (V&V) on Artificial Intelligence (Al) systems with nuclear applications. The guidelines have much broader application than just expert systems; they are also applicable to object-oriented programming systems, rule-based systems, frame-based systems, model-based systems, neural nets, genetic algorithms, and conventional software systems. This is because many of the components of AI systems are implemented in conventional procedural programming languages, so there is no real distinction. The report examines the state of the art in verifying and validating expert systems. V&V methods traditionally applied to conventional software systems are evaluated for their applicability to expert systems. One hundred fifty-three conventional techniques are identified and evaluated. These methods are found to be useful for at least some of the components of expert systems, frame-based systems, and object-oriented systems. A taxonomy of 52 defect types and their delectability by the 153 methods is presented. With specific regard to expert systems, conventional V&V methods were found to apply well to all the components of the expert system with the exception of the knowledge base. The knowledge base requires extension of the existing methods. Several innovative static verification and validation methods for expert systems have been identified and are described here, including a method for checking the knowledge base {open_quotes}semantics{close_quotes} and a method for generating validation scenarios. Evaluation of some of these methods was performed both analytically and experimentally. A V&V methodology for expert systems is presented based on three factors: (1) a system`s judged need for V&V (based in turn on its complexity and degree of required integrity); (2) the life-cycle phase; and (3) the system component being tested.

Mirsky, S.M.; Hayes, J.E.; Miller, L.A. [Science Applications International Corp., McLean, VA (United States)

1995-03-01T23:59:59.000Z

169

Effects of reduced voltage on the operation and efficiency of electric systems. Volume 3. Field tests in a northern utility service area. Final report  

SciTech Connect (OSTI)

Volume 3 of this three-volume report for RP1419-1 describes the tests on selected residential, commercial, and small industry areas of the Detroit Edison Company system and the statistical analysis performed on the test data gathered. The purpose of the field testing was to provide data to analyze changes in energy consumption due to changes in feeder voltage levels. Detroit Edison was chosen to represent a winter peaking load area. Original intent was to present these results simultaneously with results from a summer peaking load area, Texas Electric Service Company (TESCO). Unavoidable delays retarded the Detroit study results to this Volume 3. TESCO results were reported in Volume 1, and the Distribution System Analysis and Simulation (DSAS) program for these studies was presented in Volume 2 in the form of a User's Manual.

Chen, M.S.; Shoults, R.R.

1985-07-01T23:59:59.000Z

170

Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System  

E-Print Network [OSTI]

The lecture hall of the Richardson Petroleum Building at Texas A&M University is a large lecture hall, with a total floor area of approximately 2500 ft^2. The lecture hall was served by a constant air volume (CAV) air handling unit (AHU) which had...

Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E.

2000-01-01T23:59:59.000Z

171

K East Basin sludge volume estimates for integrated water treatment system  

SciTech Connect (OSTI)

Estimates were made of the volume of sludge expected from Integrated Process Strategy (IPS) processing fuel elements and in the fuel storage canisters in K East Basin, These were based on visual observations of fuel element condition in the basin and laboratory measurements of canister sludge density. The estimates, made in early 1997, are reviewed and the basic assumptions used discussed.

Pitner, A.L.

1998-08-12T23:59:59.000Z

172

APS-5: 5th international symposium on automotive propulsion systems. Volume 2  

SciTech Connect (OSTI)

Thirty papers presented at the meeting are included in this volume. A separate abstract was prepared for each of 28 papers. Two papers were previously processed for the Energy Data Base. Abstracts for individual papers were not prepared for Energy Abstracts for Policy Analysis (EAPA). (LCL)

None

1980-10-01T23:59:59.000Z

173

Computer News, Volume 21  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 21. I came, I saw, ical. There's a great new calendar and appointment book program on our system called ical at.

174

Hazard ranking system evaluation of CERCLA inactive waste sites at Hanford: Volume 2: Engineered-facility sites (HISS data base)  

SciTech Connect (OSTI)

The purpose of this report is to formally document the assessment activities at the US Department of Energy (DOE) Hanford Site. These activities were carried out pursuant to the DOE orders that address the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Program for the cleanup of inactive waste sites. The DOE orders incorporate the US Environmental Protection Agency methodology, which is based on the Superfund Amendments and Reauthorization Act of 1986. This methodology includes: PA/SI, remedial investigation/feasibility study, record of decision, design and implementation of remedial action, operation and monitoring, and verification monitoring. Volume 1 of this report discusses the CERCLA inactive waste-site evaluation process, assumptions, and results of the Hazard Ranking System methodology employed. Volume 2 presents the data on the individual CERCLA engineered-facility sites at Hanford, as contained in the Hanford Inactive Site Surveillance (HISS) Data Base. Volume 3 presents the data on the individual CERCLA unplanned-release sites at Hanford, as contained in the HISS Data Base. 13 refs.

Jette, S.J.; Lamar, D.A.; McLaughlin, T.J.; Sherwood, D.R.; Van Houten, N.C.; Stenner, R.D.; Cramer, K.H.; Higley, K.A.

1988-10-01T23:59:59.000Z

175

Human-system interface design review guideline -- Reviewer`s checklist: Final report. Revision 1, Volume 2  

SciTech Connect (OSTI)

NUREG-0700, Revision 1, provides human factors engineering (HFE) guidance to the US Nuclear Regulatory Commission staff for its: (1) review of the human system interface (HSI) design submittals prepared by licensees or applications for a license or design certification of commercial nuclear power plants, and (2) performance of HSI reviews that could be undertaken as part of an inspection or other type of regulatory review involving HSI design or incidents involving human performance. The guidance consists of a review process and HFE guidelines. The document describes those aspects of the HSI design review process that are important to the identification and resolution of human engineering discrepancies that could adversely affect plant safety. Guidance is provided that could be used by the staff to review an applicant`s HSI design review process or to guide the development of an HSI design review plan, e.g., as part of an inspection activity. The document also provides detailed HFE guidelines for the assessment of HSI design implementations. NUREG-0700, Revision 1, consists of three stand-alone volumes. Volume 2 is a complete set of the guidelines contained in Volume 1, Part 2, but in a checklist format that can be used by reviewers to assemble sets of individual guidelines for use in specific design reviews. The checklist provides space for reviewers to enter guidelines evaluations and comments.

NONE

1996-06-01T23:59:59.000Z

176

90 Communications of the Association for Information Systems (Volume 9, 2002) 90-104 The Work System Method for Understanding Information Systems and Information Systems Research  

E-Print Network [OSTI]

, systems analysis, information system development, implementation, system life cycle I. INTRODUCTION parts of the system. The dynamic view is based on the "work system life cycle model," which shows how represents its static view. The work system life cycle model represents its dynamic view of how systems

Bieber, Michael

177

IEA Wind Task 24 Integration of Wind and Hydropower Systems; Volume 2: Participant Case Studies  

SciTech Connect (OSTI)

This report describes the background, concepts, issues and conclusions related to the feasibility of integrating wind and hydropower, as investigated by the members of IEA Wind Task 24. It is the result of a four-year effort involving seven IEA member countries and thirteen participating organizations. The companion report, Volume 2, describes in detail the study methodologies and participant case studies, and exists as a reference for this report.

Acker, T.

2011-12-01T23:59:59.000Z

178

Economic evaluation of the annual cycle energy system (ACES). Final report. Volume III, appendices  

SciTech Connect (OSTI)

This volume consists of seven appendices related to ACES, the first three of which are concerned with computer programs. The appendices are entitled: (A) ACESIM: Residential Program Listing; (B) Typical Inputs and Outputs of ACESIM; (C) CACESS: Commercial Building Program Listing; (D) Typical Weather-Year Selection Requirements; (E) Building Characteristics; (F) List of Major Variables Used in the Computer Programs; and (G) Bibliography. 79 references.

Not Available

1980-06-01T23:59:59.000Z

179

Proceedings of the coal-fired power systems 94: Advances in IGCC and PFBC review meeting. Volume 1  

SciTech Connect (OSTI)

The Coal-Fired Power Systems 94 -- Advances in IGCC and PFBC Review Meeting was held June 21--23, 1994, at the Morgantown Energy Center (METC) in Morgantown, West Virginia. This Meeting was sponsored and hosted by METC, the Office of Fossil Energy, and the US Department of Energy (DOE). METC annually sponsors this conference for energy executives, engineers, scientists, and other interested parties to review the results of research and development projects; to discuss the status of advanced coal-fired power systems and future plans with the industrial contractors; and to discuss cooperative industrial-government research opportunities with METC`s in-house engineers and scientists. Presentations included industrial contractor and METC in-house technology developments related to the production of power via coal-fired Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) systems, the summary status of clean coal technologies, and developments and advancements in advanced technology subsystems, such as hot gas cleanup. A keynote speaker and other representatives from the electric power industry also gave their assessment of advanced power systems. This meeting contained 11 formal sessions and one poster session, and included 52 presentations and 24 poster presentations. Volume I contains papers presented at the following sessions: opening commentaries; changes in the market and technology drivers; advanced IGCC systems; advanced PFBC systems; advanced filter systems; desulfurization system; turbine systems; and poster session. Selected papers have been processed separately for inclusion in the Energy Science and Technology Database.

McDaniel, H.M.; Staubly, R.K.; Venkataraman, V.K. [eds.

1994-06-01T23:59:59.000Z

180

Survey of strong motion earthquake effects on thermal power plants in California with emphasis on piping systems. Volume 2, Appendices  

SciTech Connect (OSTI)

Volume 2 of the ``Survey of Strong Motion Earthquake Effects on Thermal Power Plants in California with Emphasis on Piping Systems`` contains Appendices which detail the detail design and seismic response of several power plants subjected to strong motion earthquakes. The particular plants considered include the Ormond Beach, Long Beach and Seal Beach, Burbank, El Centro, Glendale, Humboldt Bay, Kem Valley, Pasadena and Valley power plants. Included is a typical power plant piping specification and photographs of typical power plant piping specification and photographs of typical piping and support installations for the plants surveyed. Detailed piping support spacing data are also included.

Stevenson, J.D. [Stevenson and Associates, Cleveland, OH (United States)

1995-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

in: Journal of the Association of Information Systems (JAIS), Volume 10, Issue 5, May 2009, 306-332 Infrastructuring: Towards an Integrated Perspective on the  

E-Print Network [OSTI]

, Institute for Information Systems, University of Siegen and Fraunhofer FIT, Sankt Augustin, Germany, volkerin: Journal of the Association of Information Systems (JAIS), Volume 10, Issue 5, May 2009, 306, Institute for Information Systems, University of Siegen, Germany, volkmar.pipek@uni-siegen.de Volker Wulf

182

Distributed Energy Systems in California's Future: A Preliminary Report Volume 2  

E-Print Network [OSTI]

from solar heat is o These solar thermal systems provide lowTechnologies, Vol. 5, Solar Thermal Electric Systems" MITREWind Cogeneration and Solar Thermal Hydroelectric Power

Balderston, F.

2010-01-01T23:59:59.000Z

183

Transportation Sector Model of the National Energy Modeling System. Volume 2 -- Appendices: Part 3  

SciTech Connect (OSTI)

This Appendix consists of two unpublished reports produced by Energy and Environmental Analysis, Inc., under contract to Oak Ridge National Laboratory. These two reports formed the basis for the subsequent development of the Fuel Economy Model described in Volume 1. They are included in order to document more completely the efforts undertaken to construct a comprehensive model of automobile fuel economy. The supplemental reports are as follows: Supplement 1--Documentation Attributes of Technologies to Improve Automotive Fuel Economy; Supplement 2--Analysis of the Fuel Economy Boundary for 2010 and Comparison to Prototypes.

NONE

1998-01-01T23:59:59.000Z

184

DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I  

E-Print Network [OSTI]

Solar Typical Summer Weekly System Load Curve for the Pacific Southwest Site Capacity Locations of California

Authors, Various

2010-01-01T23:59:59.000Z

185

SOLERAS - Solar Controlled Environment Agriculture Project. Final report, Volume 2. Battelle Columbus Laboratories system requirements definition and system analysis  

SciTech Connect (OSTI)

System specifications, design criteria, and representative weather data necessary for the system evolution and preliminary design are generated. A detailed analysis and evaluation of the commercial-sized controlled environment agriculture system coupled with a solar energy system was conducted. A simulation model to test the performance of the greenhouse is presented. (BCS)

Not Available

1981-01-01T23:59:59.000Z

186

CroppingSystems 600 Agronomy Journal Volume 100, Issue 3 2008  

E-Print Network [OSTI]

and organic farming systems are alternatives to conventional agriculture that rely heavily on ecological pro Council (1989) focused public and scientific attention on alter- native farming systems that, in comparison with conventional systems, rely more on intensive management of ecological relationships than

Sims, Gerald K.

187

SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F9--F16 -- Volume 2, Part 2, Revision 4  

SciTech Connect (OSTI)

SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries. This volume discusses the following functional modules: MORSE-SGC; HEATING 7.2; KENO V.a; JUNEBUG-II; HEATPLOT-S; REGPLOT 6; PLORIGEN; and OCULAR.

West, J.T.; Hoffman, T.J.; Emmett, M.B.; Childs, K.W.; Petrie, L.M.; Landers, N.F.; Bryan, C.B.; Giles, G.E. [Oak Ridge National Lab., TN (United States)

1995-04-01T23:59:59.000Z

188

Investigation of Volume of Fluids (VOF) Method and System Models for Design of Microfluidic Ink Delivery Apparatus for Dip Pen Nanolithography (DPN)  

E-Print Network [OSTI]

Investigation of Volume of Fluids (VOF) Method and System Models for Design of Microfluidic Ink and manufacture of commercial microfluidic systems called "InkwellsTM". In this study VOF method was used sequence of flow in the different parts of the microfluidic network. Keywords: lab-on-chip, micro

Banerjee, Debjyoti

189

HVDC-AC system interaction from AC harmonics. Volume 1. Harmonic impedance calculations. Final report  

SciTech Connect (OSTI)

Improved methods are needed to characterize ac system harmonic behavior for ac filter design for HVDC systems. The purpose of this General Electric Company RP1138 research is to evaluate the present filter design practice and to investigate methods for calculating system harmonic impedances. An overview of ac filter design for HVDC systems and a survey of literature related to filter design have been performed. Two methods for calculating system harmonic impedances have been investigated. In the measurement method, an instrumentation system for measuring system voltage and current has been assembled. Different schemes of using the measurements to calculate system harmonic impedances have been studied. In the analytical method, a procedure to include various operating conditions has been proposed. Computer programs for both methods have been prepared, and the results of the measurement and analytical methods analyzed. A conclusion of the project is that the measurement and analytical methods both provided reasonable results. There are correlations between the measured and analytical results for most harmonics, although there are discrepancies between the assumptions used in the two methods. A sensitivity approach has been proposed to further correlate the results. From the results of the analysis, it is recommended that both methods should be tested further. For the measurement method, more testing should be done to cover different system operating conditions. In the analytical method, more detailed models for representing system components should be studied. In addition, alternative statistical and sensitivity approaches should be attempted.

Breuer, G D; Chow, J H; Lindh, C B; Miller, N W; Numrich, F H; Price, W W; Turner, A E; Whitney, R R

1982-09-01T23:59:59.000Z

190

Technical and economic assessment of fluidized bed augmented compressed air energy-storage system. Volume II. Introduction and technology assessment  

SciTech Connect (OSTI)

The results are described of a study subcontracted by PNL to the United Technologies Research Center on the engineering feasibility and economics of a CAES concept which uses a coal fired, fluidized bed combustor (FBC) to heat the air being returned from storage during the power production cycle. By burning coal instead of fuel oil, the CAES/FBC concept can completely eliminate the dependence of compressed air energy storage on petroleum fuels. The results of this assessment effort are presented in three volumes. Volume II presents a discussion of program background and an in-depth coverage of both fluid bed combustion and turbomachinery technology pertinent to their application in a CAES power plant system. The CAES/FBC concept appears technically feasible and economically competitive with conventional CAES. However, significant advancement is required in FBC technology before serious commercial commitment to CAES/FBC can be realized. At present, other elements of DOE, industrial groups, and other countries are performing the required R and D for advancement of FBC technology. The CAES/FBC will be reevaluated at a later date when FBC technology has matured and many of the concerns now plaguing FBC are resolved. (LCL)

Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

1981-09-01T23:59:59.000Z

191

Radioisotope thermoelectric generator transportation system safety analysis report for packaging. Volumes 1 and 2  

SciTech Connect (OSTI)

This SARP describes the RTG Transportation System Package, a Type B(U) packaging system that is used to transport an RTG or similar payload. The payload, which is included in this SARP, is a generic, enveloping payload that specifically encompasses the General Purpose Heat Source (GPHS) RTG payload. The package consists of two independent containment systems mounted on a shock isolation transport skid and transported within an exclusive-use trailer.

Ferrell, P.C.

1996-04-18T23:59:59.000Z

192

E-Print Network 3.0 - accelerometer systems volume Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

SYSTEMS, VOL. 11, NO. 3, JUNE ... Source: Manalis, Scott - Media Laboratory, Massachusetts Institute of Technology (MIT) Collection: Engineering ; Materials Science 6...

193

DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I  

E-Print Network [OSTI]

special problems for the use of solar energy. Available roofsolar systems becomes closely akin to problems associated with remote siting of conventional energy

Authors, Various

2010-01-01T23:59:59.000Z

194

Distributed Energy Systems in California's Future: A Preliminary Report Volume 2  

E-Print Network [OSTI]

t . • q Storage. Batteries. Individual systems, asrely upon lead-acid batteries for storage. Pumped hydraulicuses which are powered by batteries and by electric power

Balderston, F.

2010-01-01T23:59:59.000Z

195

Distributed Energy Systems in California's Future: A Preliminary Report Volume 2  

E-Print Network [OSTI]

Summary Centralized District Heating Capital RequirementsXVIII-4 Centralized District Heating Capital RequirementsFeasibility of U.S. District Heating Systems Using Waste

Balderston, F.

2010-01-01T23:59:59.000Z

196

System 80+{trademark} standard design: CESSAR design certification. Volume 15: Amendment I  

SciTech Connect (OSTI)

This report has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{trademark} Standard Design.

Not Available

1990-12-21T23:59:59.000Z

197

System 80+{trademark} standard design: CESSAR design certification. Volume 14: Amendment I  

SciTech Connect (OSTI)

This report has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{trademark} Standard Design.

Not Available

1990-12-21T23:59:59.000Z

198

DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I  

E-Print Network [OSTI]

alternative. Ocean thermal energy conversion requires anpresent designs of ocean thermal energy systems are intendedthat ocean thermal gradients will contribute energy supplies

Authors, Various

2010-01-01T23:59:59.000Z

199

User manual for GEOCITY: a computer model for cost analysis of geothermal district-heating-and-cooling systems. Volume II. Appendices  

SciTech Connect (OSTI)

The purpose of this model is to calculate the costs of residential space heating, space cooling, and sanitary water heating or process heating (cooling) using geothermal energy from a hydrothermal reservoir. The model can calculate geothermal heating and cooling costs for residential developments, a multi-district city, or a point demand such as an industrial factory or commercial building. Volume II contains all the appendices, including cost equations and models for the reservoir and fluid transmission system and the distribution system, descriptions of predefined residential district types for the distribution system, key equations for the cooling degree hour methodology, and a listing of the sample case output. Both volumes include the complete table of contents and lists of figures and tables. In addition, both volumes include the indices for the input parameters and subroutines defined in the user manual.

Huber, H.D.; Fassbender, L.L.; Bloomster, C.H.

1982-09-01T23:59:59.000Z

200

Comparative ranking of 0. 1 to 10 MW(e) solar thermal electric power systems. Volume I. Summary of results. Final report  

SciTech Connect (OSTI)

This report is part of a two-volume set summarizing the results of a comparative ranking of generic solar thermal concepts designed specifically for electric power generation. The original objective of the study was to project the mid-1990 cost and performance of selected generic solar thermal electric power systems for utility applications and to rank these systems by criteria that reflect their future commercial acceptance. This study considered plants with rated capacities of 1 to 10 MW(e), operating over a range of capacity factors from the no-storage case to 0.7 and above. Later, the study was extended to include systems with capacities from 0.1 to 1 MW(e), a range that is attractive to industrial and other non-utility applications. This volume summarizes the results for the full range of capacities from 0.1 to 10 MW(e). Volume II presents data on performance and cost and ranking methodology.

Thornton, J.P.; Brown, K.C.; Finegold, J.G.; Gresham, J.B.; Herlevich, F.A.; Kowalik, J.S.; Kriz, T.A.

1980-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

The integration of renewable energy sources into electric power distribution systems. Volume 2, Utility case assessments  

SciTech Connect (OSTI)

Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: (1) The local solar insolation and/or wind characteristics; (2) renewable energy source penetration level; (3) whether battery or other energy storage systems are applied; and (4) local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kw-scale applications may be connected to three-phase secondaries, and larger hundred-kW and MW-scale applications, such as MW-scale windfarms or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications.

Zaininger, H.W.; Ellis, P.R.; Schaefer, J.C. [Zaininger Engineering Co., San Jose, CA (United States)

1994-06-01T23:59:59.000Z

202

Proceedings of the coal-fired power systems 94: Advances in IGCC and PFBC review meeting. Volume 2  

SciTech Connect (OSTI)

The Coal-Fired Power Systems 94 -- Advances in IGCC and PFBC Review Meeting was held June 21--23, 1994, at the Morgantown Energy Center (METC) in Morgantown, West Virginia. This Meeting was sponsored and hosted by METC, the Office of Fossil Energy, and the US Department of Energy (DOE). METC annually sponsors this conference for energy executives, engineers, scientists, and other interested parties to review the results of research and development projects; to discuss the status of advanced coal-fired power systems and future plans with the industrial contractors; and to discuss cooperative industrial-government research opportunities with METC`s in-house engineers and scientists. Presentations included industrial contractor and METC in-house technology developments related to the production of power via coal-fired Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) systems, the summary status of clean coal technologies, and developments and advancements in advanced technology subsystems, such as hot gas cleanup. A keynote speaker and other representatives from the electric power industry also gave their assessment of advanced power systems. This meeting contained 11 formal sessions and one poster session, and included 52 presentations and 24 poster presentations. Volume II contains papers presented at the following sessions: filter technology issues; hazardous air pollutants; sorbents and solid wastes; and membranes. Selected papers have been processed separately for inclusion in the Energy Science and Technology Database.

McDaniel, H.M.; Staubly, R.K.; Venkataraman, V.K. [eds.

1994-06-01T23:59:59.000Z

203

Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume I. Executive summary  

SciTech Connect (OSTI)

The overall, long-term objective of the Solar Central Receiver Hybrid Power System program is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumption, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. A summary of results of Phase I is given in this volume. (WHK)

None

1980-01-01T23:59:59.000Z

204

Reliability-economics analysis models for photovoltaic power systems. Volume 1  

SciTech Connect (OSTI)

This report describes the development of modeling techniques to characterize the reliability, availability, and maintenance costs of photovoltaic power systems. The developed models can be used by designers of PV systems in making design decisions and trade-offs to minimize life-cycle energy costs.

Stember, L.H.; Huss, W.R.; Bridgman, M.S.

1982-11-01T23:59:59.000Z

205

Compliance problems of small utility systems with the Powerplant and Industrial Fuel Use Act of 1978: volume II - appendices  

SciTech Connect (OSTI)

A study of the problems of compliance with the Powerplant and Industrial Fuel Use Act of 1978 experienced by electric utility systems which have a total generating capacity of less than 2000 MW is presented. This volume presents the following appendices: (A) case studies (Farmington, New Mexico; Lamar, Colorado; Dover, Delaware; Wolverine Electric Cooperative, Michigan; Central Telephone and Utilities, Kansas; Sierra Pacific Power Company, Nevada; Vero Beach, Florida; Lubbock, Texas; Western Farmers Cooperative, Oklahoma; and West Texas Utilities Company, Texas); (B) contacts and responses to study; (C) joint action legislation chart; (D) Texas Municipal Power Agency case study; (E) existing generating units jointly owned with small utilities; (F) future generating units jointly owned with small utilities; (G) Federal Register Notice of April 17, 1980, and letter of inquiry to utilities; (H) small utility responses; and (I) Section 744, PIFUA. (WHK)

None

1981-01-01T23:59:59.000Z

206

Research and development of highly energy-efficient supermarket refrigeration systems. Volume 2. Supplemental laboratory testing  

SciTech Connect (OSTI)

The Supermarket Refrigeration System project was structured to investigate and develop a new, highly energy-efficient supermarket refrigeration system which features unequal, parallel compressors, microprocessor suction pressure control, and floating head pressure control. Energy savings are achieved because such a system is better able to match compressor capacity with the required refrigeration load. For this same reason, the unequal, parallel compressor system can operate at the lowest possible condenser pressure. The combined effect of highest possible suction pressure and lowest possible condensing pressure substantially increases the energy efficiency ratio (EER) of the refrigeration system. The test conditions included winter and spring ambient temperatures ranging from 8/sup 0/ to 70/sup 0/F, refrigerants R-12 and R-502 with corresponding evaporator temperatures of 20/sup 0/ and -20/sup 0/F, respectively, and variable refrigeration loads between 100,000 and 170,000 Btu/hr. Heat reclaim tests were performed with R-12 only. For the three sets of tests performed, R-12, R-12 with heat reclaim, and R-502, the highest system EER was achieved when the unequal, parallel compressor system was operated with microprocessor control and floating head control.

Toscano, W.M.; Walker, D.H.; Tetreault, R.D.

1983-06-01T23:59:59.000Z

207

PRODIAG: Combined expert system/neural network for process fault diagnosis. Volume 1, Theory  

SciTech Connect (OSTI)

The function of the PRODIAG code is to diagnose on-line the root cause of a thermal-hydraulic (T-H) system transient with trace back to the identification of the malfunctioning component using the T-H instrumentation signals exclusively. The code methodology is based on the Al techniques of automated reasoning/expert systems (ES) and artificial neural networks (ANN). The research and development objective is to develop a generic code methodology which would be plant- and T-H-system-independent. For the ES part the only plant or T-H system specific code requirements would be implemented through input only and at that only through a Piping and Instrumentation Diagram (PID) database. For the ANN part the only plant or T-H system specific code requirements would be through the ANN training data for normal component characteristics and the same PID database information. PRODIAG would, therefore, be generic and portable from T-H system to T-H system and from plant to plant without requiring any code-related modifications except for the PID database and the ANN training with the normal component characteristics. This would give PRODIAG the generic feature which numerical simulation plant codes such as TRAC or RELAP5 have. As the code is applied to different plants and different T-H systems, only the connectivity information, the operating conditions and the normal component characteristics are changed, and the changes are made entirely through input. Verification and validation of PRODIAG would, be T-H system independent and would be performed only ``once``.

Reifman, J.; Wei, T.Y.C.; Vitela, J.E.

1995-09-01T23:59:59.000Z

208

Distributed Energy Systems in California's Future: A Preliminary Report Volume 2  

E-Print Network [OSTI]

Energy Systems Passive solar design of buildings Solar waterbuilding settings and architectural designs can be utilized to take advantage of passive solarsolar technologies are described as either passive-- utilizing the design of the building

Balderston, F.

2010-01-01T23:59:59.000Z

209

Distributed Energy Systems in California's Future: A Preliminary Report Volume 2  

E-Print Network [OSTI]

as possible causes for solar home heating systems not beingto energy shortages. : Home heating by solar energy iseconomicallY feasib1e. 9 Home heating by solar energy is

Balderston, F.

2010-01-01T23:59:59.000Z

210

Electromagnetic transients program (EMTP): Volume 4, Workbook IV (TACS) (Transients Analysis of Control Systems): Final report  

SciTech Connect (OSTI)

This workbook represents an introduction to the use of TACS (Transients Analysis of Control Systems) in the EMTP. The material progresses from an overview of basic TACS concepts and components to a detailed HVDC model. The following application of TACS are covered: a variable load problem, static Var systems, thyristor models, TCR, basic HVDC models and a detailed HVDC model. Complete data files are given for most examples.

Lasseter, R.H.

1989-06-01T23:59:59.000Z

211

Transportation Sector Model of the National Energy Modeling System. Volume 2 -- Appendices: Part 2  

SciTech Connect (OSTI)

The attachments contained within this appendix provide additional details about the model development and estimation process which do not easily lend themselves to incorporation in the main body of the model documentation report. The information provided in these attachments is not integral to the understanding of the model`s operation, but provides the reader with opportunity to gain a deeper understanding of some of the model`s underlying assumptions. There will be a slight degree of replication of materials found elsewhere in the documentation, made unavoidable by the dictates of internal consistency. Each attachment is associated with a specific component of the transportation model; the presentation follows the same sequence of modules employed in Volume 1. The following attachments are contained in Appendix F: Fuel Economy Model (FEM)--provides a discussion of the FEM vehicle demand and performance by size class models; Alternative Fuel Vehicle (AFV) Model--describes data input sources and extrapolation methodologies; Light-Duty Vehicle (LDV) Stock Model--discusses the fuel economy gap estimation methodology; Light Duty Vehicle Fleet Model--presents the data development for business, utility, and government fleet vehicles; Light Commercial Truck Model--describes the stratification methodology and data sources employed in estimating the stock and performance of LCT`s; Air Travel Demand Model--presents the derivation of the demographic index, used to modify estimates of personal travel demand; and Airborne Emissions Model--describes the derivation of emissions factors used to associate transportation measures to levels of airborne emissions of several pollutants.

NONE

1998-01-01T23:59:59.000Z

212

Development of a Dispatchable PV Peak Shainv System. PV: Bonus Program - Phase 1 Report. Volume 1  

SciTech Connect (OSTI)

This report summarizes the work performed by Delmarva Power and Light and its subcontractors in Phase 1 of the US Department of Energy's PV:BONUS Program. The purpose of the program is to develop products and systems for buildings which utilize photovoltaic (N) technology. Beginning with a cooperative research effort with the University of Delaware's Center for Energy and Environmental Policy Research Delmarva Power developed and demonstrated the concept of Dispatchable PV Peak Shaving. This concept and the system which resulted horn the development work are unique from other grid-connected PV systems because it combines a PV, battery energy storage, power conversion and control technologies into an integrated package. Phase 1 began in July 1993 with the installation of a test and demonstration system at Delmarva's Northern Division General Office building near Newark, Delaware. Following initial testing throughout the summer and fall of 1993, significant modifications were made under an amendment to the DOE contract. Work on Phase 1 concluded in the early spring of 1995. Significant progress towards the goal of commercializing the system was made during Phase 1, and is summarized. Based on progress in Phase 1, a proposal to continue the work in Phase 2 was submitted to the US DOE in May 1995. A contract amendment and providing funds for the Phase 2 work is expected in July 1995.

None

1995-10-01T23:59:59.000Z

213

Building America Best Practices Series, Volume 6: High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems  

SciTech Connect (OSTI)

This guide is was written by PNNL for the US Department of Energy's Building America program to provide information for residential production builders interested in building near zero energy homes. The guide provides indepth descriptions of various roof-top photovoltaic power generating systems for homes. The guide also provides extensive information on various designs of solar thermal water heating systems for homes. The guide also provides construction company owners and managers with an understanding of how solar technologies can be added to their homes in a way that is cost effective, practical, and marketable. Twelve case studies provide examples of production builders across the United States who are building energy-efficient homes with photovoltaic or solar water heating systems.

Baechler, Michael C.; Gilbride, Theresa L.; Ruiz, Kathleen A.; Steward, Heidi E.; Love, Pat M.

2007-06-04T23:59:59.000Z

214

SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F1--F8 -- Volume 2, Part 1, Revision 4  

SciTech Connect (OSTI)

SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation; Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries.

Greene, N.M.; Petrie, L.M.; Westfall, R.M.; Bucholz, J.A.; Hermann, O.W.; Fraley, S.K. [Oak Ridge National Lab., TN (United States)

1995-04-01T23:59:59.000Z

215

Evaluation of solar radiation measurement systems: EPRI/NREL final test report. Volume 1  

SciTech Connect (OSTI)

Measured solar radiation resource data are needed by electric utilities to evaluate the potential of renewable energy options like photovoltaics in their service territory. In this final test report, we document a cooperative project of the Electric Power Research Institute (EPRI) and the National Renewable Energy Laboratory (NREL) to compare available measurement system options for performing solar radiation resource assessments. We present the detailed results of a 6-month field comparison of thermopile-based pyranometer and pyrheliometer solar irradiance measurement systems with two different implementations of the rotating shadowband radiometer (RSR) concept installed at NREL`s Solar Radiation Research Laboratory (SRRL) in Golden, Colorado.

Stoffel, T.; Riordan, C.; Bigger, J.

1992-11-01T23:59:59.000Z

216

MRS system study for the repository: Yucca Mountain Site Characterization Project; Volume 2  

SciTech Connect (OSTI)

The US Department of Energy (DOE), Office of Civilian Radioactive Waste Management (OCRWM), has initiated a waste management system study to identify the impacts of the presence or absence of a monitored retrievable storage facility (hereinafter referred to as ``MRS``) on system costs and program schedules. To support this study, life-cycle cost estimates and construction schedules have been prepared for the surface and underground facilities and operations geologic nuclear waste repository at Yucca Mountain, Nye County, Nevada. Nine different operating scenarios (cases) have been identified by OCRWM for inclusion in this study. For each case, the following items are determined: the repository design and construction costs, operating costs, closure and decommissioning costs, required staffing, construction schedules, uncertainties associated with the costs and schedules, and shipping cask and disposal container throughputs. This document contains A-D.

Sinagra, T.A. [Bechtel National, Inc., San Francisco, CA (USA); Harig, R. [Parsons, Brinckerhoff, Quade and Douglas, Inc., San Francisco, CA (USA)

1990-12-01T23:59:59.000Z

217

Hanford Environmental Information System (HEIS) Operator`s Manual. Volume 1  

SciTech Connect (OSTI)

The Hanford Environmental Information System (HEIS) is a consolidated set of automated resources that effectively manage the data gathered during environmental monitoring and restoration of the Hanford Site. The HEIS includes an integrated database that provides consistent and current data to all users and promotes sharing of data by the entire user community. This manual describes the facilities available to the operational user who is responsible for data entry, processing, scheduling, reporting, and quality assurance. A companion manual, the HEIS User`s Manual, describes the facilities available-to the scientist, engineer, or manager who uses the system for environmental monitoring, assessment, and restoration planning; and to the regulator who is responsible for reviewing Hanford Site operations against regulatory requirements and guidelines.

Schreck, R.I.

1991-10-01T23:59:59.000Z

218

Generation IV Nuclear Energy Systems Ten-Year Program Plan Fiscal Year 2005, Volume 1  

SciTech Connect (OSTI)

As reflected in the U.S. ''National Energy Policy'', nuclear energy has a strong role to play in satisfying our nation's future energy security and environmental quality needs. The desirable environmental, economic, and sustainability attributes of nuclear energy give it a cornerstone position, not only in the U.S. energy portfolio, but also in the world's future energy portfolio. Accordingly, on September 20, 2002, U.S. Energy Secretary Spencer Abraham announced that, ''The United States and nine other countries have agreed to develop six Generation IV nuclear energy concepts''. The Secretary also noted that the systems are expected to ''represent significant advances in economics, safety, reliability, proliferation resistance, and waste minimization''. The six systems and their broad, worldwide research and development (R&D) needs are described in ''A Technology Roadmap for Generation IV Nuclear Energy Systems'' (hereafter referred to as the Generation IV Roadmap). The first 10 years of required U.S. R&D contributions to achieve the goals described in the Generation IV Roadmap are outlined in this Program Plan.

None

2005-03-01T23:59:59.000Z

219

International Journal of Systems Science, 1998, volume 29, number 9, pages 939-951 Performance analysis of serial production lines with quality  

E-Print Network [OSTI]

International Journal of Systems Science, 1998, volume 29, number 9, pages 939-951 Performance analysis of serial production lines with quality inspection machines M.-S. HANt, i.-T. LIMt* and D. The high production rate of machines in isolation and quality inspection machines are the basis of highly

Lim, Jong-Tae

220

HERA-B Gas Systems The gas mixture, the gas volume of the corresponding detector and the required gas flow are given. All detectors are operating at nominal  

E-Print Network [OSTI]

HERA-B Gas Systems The gas mixture, the gas volume of the corresponding detector and the required gas flow are given. All detectors are operating at nominal pressure within a given tolerance p. The pipes connecting the external gas hut with the third floor of the electronics trailer are listed on page

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Cooking the volumes  

E-Print Network [OSTI]

Cooking possesses a system of units of measurement, that includes measures of volumes based on pre-metric units. This paper discusses the cooking measures and compares their features with those of the ancient Roman measures of capacity.

Sparavigna, Amelia Carolina

2012-01-01T23:59:59.000Z

222

Supply fan energy use in pressurized underfloor air distribution systems  

E-Print Network [OSTI]

air-water devices like fan coil units and water source heatsuch as VAV boxes and fan coil units. One fairly typical

Webster, Tom P.E.; Bauman, Fred P.E.; Ring, Erik P.E.

2000-01-01T23:59:59.000Z

223

Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1  

SciTech Connect (OSTI)

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

NONE

1998-01-01T23:59:59.000Z

224

BLAST FURNACE GRANULAR COAL INJECTION SYSTEM. Final Report Volume 2: Project Performance and Economics  

SciTech Connect (OSTI)

Bethlehem Steel Corporation (BSC) requested financial assistance from the Department of Energy (DOE), for the design, construction and operation of a 2,800-ton-per-day blast furnace granulated coal injection (BFGCI) system for two existing iron-making blast furnaces. The blast furnaces are located at BSC's facilities in Burns Harbor, Indiana. The demonstration project proposal was selected by the DOE and awarded to Bethlehem in November 1990. The design of the project was completed in December 1993 and construction was completed in January 1995. The equipment startup period continued to November 1995 at which time the operating and testing program began. The blast furnace test program with different injected coals was completed in December 1998.

Unknown

1999-10-01T23:59:59.000Z

225

DEVELOPMENT OF A NATURAL GAS SYSTEMS ANALYSIS MODEL (GSAM) VOLUME I - SUMMARY REPORT VOLUME II - USER'S GUIDE VOLUME IIIA - RP PROGRAMMER'S GUIDE VOLUME IIIB - SRPM PROGRAMMER'S GUIDE VOLUME IIIC - E&P PROGRAMMER'S GUIDE VOLUME IIID - D&I PROGRAMMER'S GUIDE  

SciTech Connect (OSTI)

This report summarizes work completed on DOE Contract DE-AC21-92MC28138, Development of a Natural Gas Systems Analysis Model (GSAM). The products developed under this project directly support the National Energy Technology Laboratory (NETL) in carrying out its natural gas R&D mission. The objective of this research effort has been to create a comprehensive, non-proprietary, microcomputer model of the North American natural gas market. GSAM has been developed to explicitly evaluate components of the natural gas system, including the entire in-place gas resource base, exploration and development technologies, extraction technology and performance parameters, transportation and storage factors, and end-use demand issues. The system has been fully tested and calibrated and has been used for multiple natural gas metrics analyses at NETL in which metric associated with NETL natural gas upstream R&D technologies and strategies under the direction of NETL has been evaluated. NETL's Natural Gas Strategic Plan requires that R&D activities be evaluated for their ability to provide adequate supplies of reasonably priced natural gas. GSAM provides the capability to assess potential and on-going R&D projects using a full fuel cycle, cost-benefit approach. This method yields realistic, market-based assessments of benefits and costs of alternative or related technology advances. GSAM is capable of estimating both technical and commercial successes, quantifying the potential benefits to the market, as well as to other related research. GSAM, therefore, represents an integration of research activities and a method for planning and prioritizing efforts to maximize benefits and minimize costs. Without an analytical tool like GSAM, NETL natural gas upstream R&D activities cannot be appropriately ranked or focused on the most important aspects of natural gas extraction efforts or utilization considerations.

Unknown

2001-02-01T23:59:59.000Z

226

Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume IX. Reactor and fuel cycle description  

SciTech Connect (OSTI)

The Nonproliferation Alterntive Systems Assessment Program (NASAP) has characterized and assessed various reactor/fuel-cycle systems. Volume IX provides, in summary form, the technical descriptions of the reactor/fuel-cycle systems studied. This includes the status of the system technology, as well as a discussion of the safety, environmental, and licensing needs from a technical perspective. This information was then used in developing the research, development, and demonstration (RD and D) program, including its cost and time frame, to advance the existing technology to the level needed for commercial use. Wherever possible, the cost data are given as ranges to reflect the uncertainties in the estimates.

Not Available

1980-06-01T23:59:59.000Z

227

Transportation Sector Model of the National Energy Modeling System. Volume 1  

SciTech Connect (OSTI)

This report documents the objectives, analytical approach and development of the National Energy Modeling System (NEMS) Transportation Model (TRAN). The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated by the model. The NEMS Transportation Model comprises a series of semi-independent models which address different aspects of the transportation sector. The primary purpose of this model is to provide mid-term forecasts of transportation energy demand by fuel type including, but not limited to, motor gasoline, distillate, jet fuel, and alternative fuels (such as CNG) not commonly associated with transportation. The current NEMS forecast horizon extends to the year 2010 and uses 1990 as the base year. Forecasts are generated through the separate consideration of energy consumption within the various modes of transport, including: private and fleet light-duty vehicles; aircraft; marine, rail, and truck freight; and various modes with minor overall impacts, such as mass transit and recreational boating. This approach is useful in assessing the impacts of policy initiatives, legislative mandates which affect individual modes of travel, and technological developments. The model also provides forecasts of selected intermediate values which are generated in order to determine energy consumption. These elements include estimates of passenger travel demand by automobile, air, or mass transit; estimates of the efficiency with which that demand is met; projections of vehicle stocks and the penetration of new technologies; and estimates of the demand for freight transport which are linked to forecasts of industrial output. Following the estimation of energy demand, TRAN produces forecasts of vehicular emissions of the following pollutants by source: oxides of sulfur, oxides of nitrogen, total carbon, carbon dioxide, carbon monoxide, and volatile organic compounds.

NONE

1998-01-01T23:59:59.000Z

228

Sperry Low Temperature Geothermal Conversion System, Phase 1 and Phase II. Final report. Volume III. Systems description  

SciTech Connect (OSTI)

The major fraction of hydrothermal resources that have the prospect of being economically useful for the generation of electricity are in the 300/sup 0/F to 425/sup 0/F temperature range. Cost-effective conversion of the geothermal energy to electricity requires the conception and reduction to practice of new ideas to improve conversion efficiency, enhance brine flow, reduce plant costs, increase plant availability, and shorten the time between investment and return. The problems addressed during past activities are those inherent in the geothermal environment, in the binary fluid cycle, in the difficulty of efficiently converting the energy of a low-temperature resource, and in geothermal economics. Explained in detail in this document, some of these problems are: the energy expended by the down-hole pump; the difficulty in designing reliable down-hole equipment; fouling of heat-exchanger surfaces by geothermal fluids; the unavailability of condenser cooling water at most geothermal sites; the large portion of the available energy used by the feed pump in a binary system; the pinch effect - a loss in available energy in transferring heat from water to an organic fluid; flow losses in fluids that carry only a small amount of useful energy to begin with; high heat-exchanger costs - the lower the temperature interval of the cycle, the higher the heat exchanger costs in $/kW (actually, more than inversely proportional); the complexity and cost of the many auxiliary elements of proposed geothermal plants; and the unfortunate cash flow vs. investment curve caused by the many years of investment required to bring a field into production before any income is realized.

Matthews, H.B.

1984-01-01T23:59:59.000Z

229

U.S. Department of Energy Space and Defense Power Systems Program Ten-Year Strategic Plan, Volume 1 and Volume 2  

SciTech Connect (OSTI)

The Department of Energy's Space and Defense Power Systems program provides a unique capability for supplying power systems that function in remote or hostile environments. This capability has been functioning since the early 1960s and counts the National Aeronautics and Space Administration as one of its most prominent customers. This enabling technology has assisted the exploration of our solar system including the planets Jupiter, Saturn, Mars, Neptune, and soon Pluto. This capability is one-of-kind in the world in terms of its experience (over five decades), breadth of power systems flown (over two dozen to date) and range of power levels (watts to hundreds of watts). This document describes the various components of that infrastructure, work scope, funding needs, and its strategic plans going forward.

Dwight, Carla

2013-06-01T23:59:59.000Z

230

To appear in C. A. Hooker, Philosophy of Complex Systems. Handbook of the Philosophy of Science, Volume 10. Elsevier.  

E-Print Network [OSTI]

, Volume 10. Elsevier. Complex Biological Mechanisms: Cyclic, Oscillatory, and Autonomous William Bechtel as the primary explanatory vehicle; for them, a scientific observation is explained by formally deriving it from

Bechtel, William

231

User manual for AQUASTOR: a computer model for cost analysis of aquifer thermal energy storage coupled with district heating or cooling systems. Volume I. Main text  

SciTech Connect (OSTI)

A computer model called AQUASTOR was developed for calculating the cost of district heating (cooling) using thermal energy supplied by an aquifer thermal energy storage (ATES) system. The AQUASTOR model can simulate ATES district heating systems using stored hot water or ATES district cooling systems using stored chilled water. AQUASTOR simulates the complete ATES district heating (cooling) system, which consists of two principal parts: the ATES supply system and the district heating (cooling) distribution system. The supply system submodel calculates the life-cycle cost of thermal energy supplied to the distribution system by simulating the technical design and cash flows for the exploration, development, and operation of the ATES supply system. The distribution system submodel calculates the life-cycle cost of heat (chill) delivered by the distribution system to the end-users by simulating the technical design and cash flows for the construction and operation of the distribution system. The model combines the technical characteristics of the supply system and the technical characteristics of the distribution system with financial and tax conditions for the entities operating the two systems into one techno-economic model. This provides the flexibility to individually or collectively evaluate the impact of different economic and technical parameters, assumptions, and uncertainties on the cost of providing district heating (cooling) with an ATES system. This volume contains the main text, including introduction, program description, input data instruction, a description of the output, and Appendix H, which contains the indices for supply input parameters, distribution input parameters, and AQUASTOR subroutines.

Huber, H.D.; Brown, D.R.; Reilly, R.W.

1982-04-01T23:59:59.000Z

232

Volume Project  

E-Print Network [OSTI]

Math 13900. Volume Project. For the following project, you may use any materials. This must be your own original creation. Construct a right pyramid with a base ...

rroames

2010-01-12T23:59:59.000Z

233

Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume III. Appendices  

SciTech Connect (OSTI)

The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)

Slemmons, A J

1980-04-01T23:59:59.000Z

234

Comparative ranking of 0. 1-10 MW/sub e/ solar thermal electric power systems. Volume II. Supporting data. Final report  

SciTech Connect (OSTI)

This report is part of a two-volume set summarizing the results of a comparative ranking of generic solar thermal concepts designed specifically for electric power generation. The original objective of the study was to project the mid-1990 cost and performance of selected generic solar thermal electric power systems for utility applications and to rank these systems by criteria that reflect their future commercial acceptance. This study considered plants with rated capacities of 1-10 MW/sub e/, operating over a range of capacity factors from the no-storage case to 0.7 and above. Later, the study was extended to include systems with capacities from 0.1 to 1 MW/sub e/, a range that is attractive to industrial and other nonutility applications. Volume I summarizes the results for the full range of capacities from 0.1 to 1.0 MW/sub e/. Volume II presents data on the performance and cost and ranking methodology.

Thornton, J.P.; Brown, K.C.; Finegold, J.G.; Gresham, J.B.; Herlevich, F.A.; Kriz, T.A.

1980-07-01T23:59:59.000Z

235

Building Energy Information Systems: State of the Technology and User Case Studies  

E-Print Network [OSTI]

Diagnostic trends of VAV zone temperatures HVAC 0200 - 4 1trend points. Each day eight person hours are dedicated to building-by-building HVAC

Granderson, Jessica

2010-01-01T23:59:59.000Z

236

 Underfloor air distribution (UFAD) cost study: analysis of first cost tradeoffs in UFAD systems  

E-Print Network [OSTI]

is served by VAV fan coil units (FCU) with variable speedwith regard to terminal fan coil unit costs. Since the model

Webster, Tom; Benedek, Corinne; Bauman, Fred

2006-01-01T23:59:59.000Z

237

INFLUENCE OF SUPPLY AIR TEMPERATURE ON UNDERFLOOR AIR DISTRIBUTION (UFAD) SYSTEM ENERGY PERFORMANCE  

E-Print Network [OSTI]

chilled water cooling coil, and supply fan. The fan is aspecify the VAV box cooling design supply air temperature (the underfloor supply plenum (thereby, reducing room cooling

2012-01-01T23:59:59.000Z

238

CX-001530: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

on existing structures); JJC Day Room Variable Air Volume (VAV) Retrofit; Central Library Air Handler Replacement; Library Heating, Ventilating, and Air Conditioning (HVAC)...

239

Failure mode analysis for lime/limestone FGD system. Volume III. Plant profiles. Part 1 of 3  

SciTech Connect (OSTI)

This volume contains plant profiles for: Petersburg 3; Hawthorn 3, 4; La Cygne 1; Jeffry 1, 2; Lawrence 4, 5; Green River 1-3; Cane Run 4, 5; Mill Creek 1, 3; Paddy's Run 6; Clay Boswell 4; Milton R. Young 2; Pleasants 1, 2; and Colstrip 1, 2. (DLC)

Kenney, S.M.; Rosenberg, H.S.; Nilsson, L.I.O.; Oxley, J.H.

1984-08-01T23:59:59.000Z

240

Water Quality Program, Volume 1 (Alabama)  

Broader source: Energy.gov [DOE]

This volume of the water quality program mainly deals with the National Pollutant Discharge Elimination System. National Pollutant Discharge Elimination System" or "(NPDES)" means the national...

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

User manual for AQUASTOR: a computer model for cost analysis of aquifer thermal-energy storage oupled with district-heating or cooling systems. Volume II. Appendices  

SciTech Connect (OSTI)

A computer model called AQUASTOR was developed for calculating the cost of district heating (cooling) using thermal energy supplied by an aquifer thermal energy storage (ATES) system. the AQUASTOR Model can simulate ATES district heating systems using stored hot water or ATES district cooling systems using stored chilled water. AQUASTOR simulates the complete ATES district heating (cooling) system, which consists of two prinicpal parts: the ATES supply system and the district heating (cooling) distribution system. The supply system submodel calculates the life-cycle cost of thermal energy supplied to the distribution system by simulating the technical design and cash flows for the exploration, development, and operation of the ATES supply system. The distribution system submodel calculates the life-cycle cost of heat (chill) delivered by the distribution system to the end-users by simulating the technical design and cash flows for the construction and operation of the distribution system. The model combines the technical characteristics of the supply system and the technical characteristics of the distribution system with financial and tax conditions for the entities operating the two systems into one techno-economic model. This provides the flexibility to individually or collectively evaluate the impact of different economic and technical parameters, assumptions, and uncertainties on the cost of providing district heating (cooling) with an ATES system. This volume contains all the appendices, including supply and distribution system cost equations and models, descriptions of predefined residential districts, key equations for the cooling degree-hour methodology, a listing of the sample case output, and appendix H, which contains the indices for supply input parameters, distribution input parameters, and AQUASTOR subroutines.

Huber, H.D.; Brown, D.R.; Reilly, R.W.

1982-04-01T23:59:59.000Z

242

Final safety evaluation report related to the certification of the System 80{sup +} design (Docket No. 52-002). Volume 2, Chapters 15--22 and appendices  

SciTech Connect (OSTI)

This final safety evaluation report (FSER) documents the technical review of the System 80+ standard design by the US Nuclear Regulatory Commission (NRC) staff. The application for the system 80+ design was submitted by Combustion Engineering, Inc., now Asea Brown Boveri-Combustion Engineering (ABB-CE) as an application for design approval and subsequent design certification pursuant to 10 CFR {section} 52.45. System 80+ is a pressurized water reactor with a rated power of 3914 megawatts thermal (MWt) and a design power of 3992 MWt at which accidents are analyzed. Many features of the System 80+ are similar to those of ABB-CE`s System 80 design from which it evolved. Unique features of the System 80+ design include: a large spherical, steel containment; an in-containment refueling water storage tank; a reactor cavity flooding system, hydrogen ignitors and a safety depressurization system for severe accident mitigation; a combustion gas turbine for an alternate ac source; and an advanced digitally based control room. On the basis of its evaluation and independent analyses, the NRC staff concludes that ABB-CE`s application for design certification meets the requirements of Subpart B of 10 CFR Part 52 that are applicable and technically relevant to the System 80+ standard design. This document, Volume 2, contains Chapters 15 through 22 and Appendices A through E.

Not Available

1994-08-01T23:59:59.000Z

243

Final safety evaluation report related to the certification of the System 80{sup +} design (Docket No. 52-002). Volume 1, Chapters 1--14  

SciTech Connect (OSTI)

This final safety evaluation report (FSER) documents the technical review of the System 80+ standard design by the US Nuclear Regulatory Commission (NRC) staff. The application for the System 80+ design was submitted by Combustion Engineering, Inc., now Asea Brown Boveri-Combustion Engineering (ABB-CE) as an application for design approval and subsequent design certification pursuant to 10 CFR {section} 52.45. System 80+ is a pressurized water reactor with a rated power of 3914 megawatts thermal (MWt) and a design power of 3992 MWt at which accidents are analyzed. Many features of the System 80+ are similar to those of Abb-CE`s System 80 design from which it evolved. Unique features of the System 80+ design included: a large spherical, steel containment; an in-containment refueling water storage tank; a reactor cavity flooding system, hydrogen ignitors, and a safety depressurization system for severe accident mitigation; a combustion gas turbine for an alternate ac source; and an advanced digitally based control room. On the basis of its evaluation and independent analyses, the NRC staff concludes that ABB-CE`s application for design certification meets the requirements of Subpart B of 10 CFR Part 52 that are applicable and technically relevant to the System 80+ standard design. This document, Volume 1, contains Chapters 1 through 14 of this report.

Not Available

1994-08-01T23:59:59.000Z

244

Utility FGD Survey, January--December 1989. Volume 2, Design performance data for operating FGD systems, Part 1  

SciTech Connect (OSTI)

The Utility flue gas desulfurization (FGD) Survey report, which is generated by a computerized data base management system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems. It summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. The development status (operational, under construction, or in the planning stages), system supplier, process, waste disposal practice, and regulatory class are tabulated alphabetically by utility company.

Hance, S.L.; McKibben, R.S.; Jones, F.M. [IT Corp., Cincinnati, OH (United States)

1992-03-01T23:59:59.000Z

245

Research and development of highly energy-efficient supermarket refrigeration systems. Volume 1. Executive summary and task reports  

SciTech Connect (OSTI)

The Supermarket Energy Systems Project was structured to investigate and develop new highly energy-efficient supermarket refrigeration systems. A market and system analysis was performed for supermarket energy systems. The market analysis describes the overall structure of the supermarket industry as well as the distribution of energy-using systems in a typical supermarket. The market analysis evaluates the supermarket industry and the typical supermarket as customers buying energy-saving equipment. The systems analysis includes all supermarket energy-saving systems but focuses on the refrigeration system, the major energy-consuming system in a supermarket. A computer simulation program for supermarket refrigeration was developed and has been used to perform a sensitivity analysis, identifying those improvements or changes to the refrigeration system which offer the greatest energy-saving potential. Energy-saving improvements are described and evaluated. The results of the marketing and system analyses are combined with government, manufacturer, and customer criteria to rank various energy-saving improvements in order of desirability for further study, development and commercialization. A supermarket refrigeration system consisting of: unequal, parallel compressors; condenser with floating head-pressure control; and a microprocessor-based electronic control system was analyzed, designed, fabricated, and recommended. A compressor capacity control algorithm was designed to select the optimum compressor combination for each operating condition to match compressor capacity to refrigeration load. A microprocessor system based on an Intel 8085 microprocessor was selected for system control and data acquisition. An economic analysis was performed.

Toscano, W.M.; Heaton, D.M.; Krepchin, I.P.; Lee, K.; Oven, M.J.; Walker, D.H.

1981-10-01T23:59:59.000Z

246

Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 11, 0.11 Specialty systems  

SciTech Connect (OSTI)

General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; system work breakdown structure; and general system/material data. Deficiency standards and inspection methods are presented for canopies; loading dock systems; tanks; domes (bulk storage, metal framing); louvers & vents; access floors; integrated ceilings; and mezzanine structures.

Not Available

1993-05-01T23:59:59.000Z

247

The second iteration of the Systems Prioritization Method: A systems prioritization and decision-aiding tool for the Waste Isolation Pilot Plant: Volume 2, Summary of technical input and model implementation  

SciTech Connect (OSTI)

The Systems Prioritization Method (SPM) is a decision-aiding tool developed by Sandia National Laboratories (SNL). SPM provides an analytical basis for supporting programmatic decisions for the Waste Isolation Pilot Plant (WIPP) to meet selected portions of the applicable US EPA long-term performance regulations. The first iteration of SPM (SPM-1), the prototype for SPM< was completed in 1994. It served as a benchmark and a test bed for developing the tools needed for the second iteration of SPM (SPM-2). SPM-2, completed in 1995, is intended for programmatic decision making. This is Volume II of the three-volume final report of the second iteration of the SPM. It describes the technical input and model implementation for SPM-2, and presents the SPM-2 technical baseline and the activities, activity outcomes, outcome probabilities, and the input parameters for SPM-2 analysis.

Prindle, N.H.; Mendenhall, F.T.; Trauth, K.; Boak, D.M. [Sandia National Labs., Albuquerque, NM (United States); Beyeler, W. [Science Applications International Corp., Albuquerque, NM (United States); Hora, S. [Hawaii Univ., Hilo, HI (United States); Rudeen, D. [New Mexico Engineering Research Inst., Albuquerque, NM (United States)

1996-05-01T23:59:59.000Z

248

Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume II, Book 2. Conceptual design, Sections 5 and 6  

SciTech Connect (OSTI)

The overall, long-term objective of the Solar Central Receiver Hybrid Power System program is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumption, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume contains the detailed conceptual design and cost/performance estimates and an assessment of the commercial scale solar central receiver hybrid power system. (WHK)

None

1980-01-01T23:59:59.000Z

249

Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume II, Book 1. Conceptual design, Sections 1 through 4  

SciTech Connect (OSTI)

The overall, long-term objective of the Solar Central Receiver Hybrid Power System program is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumption, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume presents in detail the market analysis, parametric analysis, and the selection process for the preferred system. (WHK)

None

1980-01-01T23:59:59.000Z

250

220 Communications of the Association for Information Systems (Volume 13, 2004)220-232 The Australian Produce Co-Operative; A Global Information Systems Project by H. Lehmann  

E-Print Network [OSTI]

is intertwined with the pre-existing politically charged environment that characterizes the global firm. Further an international information system as it follows APCO's global system development. It shows the difficulties systems implementation, multinational companies, politics in multinational companies, international

Bieber, Michael

251

PATRAM '80. Proceedings. Volume 1  

SciTech Connect (OSTI)

Volume 1 contains papers from the following sessions: Plenary Session; Regulations, Licensing and Standards; LMFBR Systems Concepts; Risk/Safety Assessment I; Systems and Package Design; US Institutional Issues; Risk/Safety Assessment II; Leakage, Leak Rate and Seals; Poster Session A; Operations and Systems Experience I; Manufacturing Processes and Materials; and Quality Assurance and Maintenance. Individual papers were processed. (LM)

Huebner, H.W. (ed.)

1980-01-01T23:59:59.000Z

252

PATRAM '80. Proceedings. Volume 2  

SciTech Connect (OSTI)

Volume 2 contains papers from the following sessions: Safeguards-Related Problems; Neutronics and Criticality; Operations and Systems Experience II; Plutonium Systems; Intermediate Storage in Casks; Operations and Systems Planning; Institutional Issues; Structural and Thermal Evaluation I; Poster Session B; Extended Testing I; Structural and Thermal Evaluation II; Extended Testing II; and Emergency Preparedness and Response. Individual papers were processed. (LM)

Huebner, H.W. (ed.)

1980-01-01T23:59:59.000Z

253

SOLERAS - Solar Controlled Environment Agriculture Project. Final report, Volume 4. Saudi Engineering Solar Energy Applications System Design Study  

SciTech Connect (OSTI)

Literature summarizing a study on the Saudi Arabian solar controlled environment agriculture system is presented. Specifications and performance requirements for the system components are revealed. Detailed performance and cost analyses are used to determine the optimum design. A preliminary design of an engineering field test is included. Some weather data are provided for Riyadh, Saudi Arabia. (BCS)

Not Available

1985-01-01T23:59:59.000Z

254

Research and development of highly energy-efficient supermarket refrigeration systems. Volume 3. Evaluation of a test system in a supermarket  

SciTech Connect (OSTI)

This report covers in detail the engineering evaluation of a highly energy-efficient supermarket refrigeration system. The primary components of this system were a set of three unequal parallel compressors, a microprocessor-based compressor controller, and floating head pressure for condenser operation. For this evaluation, such a system - referred to here as the test system - was designed, fabricated, installed and instrumented in a supermarket operated by the H.E. Butt Grocery Co., in San Antonio, TX. A second refrigeration system - referred to here as the reference system and located in another HEB supermarket in San Antonio - was also instrumented so that comparative measurements between the two systems could be made. The major components of the reference system were two equal parallel compressors, a solid state compressor controller, and conventional head pressure control. The two systems were monitored for a period of approximately one year. The results showed that the test system produced a system EER (energy efficiency ratio) that was on the average 15.9% higher than that of the reference system. Further analysis of the performance data showed that the following parameters (presented in descending order of importance) contributed to this improvement: Operation of the test system at higher suction pressure; cycling control strategy for the test system condenser fans; fewer defrosts experienced by the test system; and operation of the test system at lower condenser pressure. Similar analyses were carried out for the power consumptions and refrigeration loads of both the test and reference systems. 9 figures, 10 tables.

Walker, D.H.; Burnett, M.; Krepchin, I.P.

1984-12-01T23:59:59.000Z

255

Analysis of concentrating PV-T systems for the commercial/industrial sector. Volume III. Technical issues and design guidance  

SciTech Connect (OSTI)

This report provide appropriate guidance for addressing the major technical issues associated with the design and installation of a photovoltaic-thermal (PV-T) system. Nomographs are presented for developing preliminary sizing and costing, and issues associated with specific components and the overall design of the electrical and mechanical system are discussed. SAND82-7157/2 presents a review of current PV-T technology and operating systems and a study of potential PV-T applications. Detailed PV-T system designs for three selected applications and the results of a trade-off study for these applications are presented in SAND82-7157/4. A summary of the major results of this entire study and conclusions concerning PV-T systems and applications is presented in SAND82-7157/1.

Schwinkendorf, W.E.

1984-09-01T23:59:59.000Z

256

Volume Comparison  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500IIVasudhaSurface. | EMSLVisualizingwith SalicylamideVolume

257

Lean manufacturing system design and value stream management in a high-mix, low-volume environment  

E-Print Network [OSTI]

Value Stream Mapping is a powerful tool for identifying sources of waste and for creating the vision for the future state of a production system. As a management tool, however, it lacks in specific focus of roles, ...

Gates, Matthew David, 1973-

2004-01-01T23:59:59.000Z

258

Tokamak Physics EXperiment (TPX): Toroidal field magnet design, development and manufacture. SDRL 15, System design description. Volume 1  

SciTech Connect (OSTI)

This System Design Description, prepared in accordance with the TPX Project Management Plan provides a summary or TF Magnet System design features at the conclusion of Phase I, Preliminary Design and Manufacturing Research. The document includes the analytical and experimental bases for the design, and plans for implementation in final design, manufacturing, test, and magnet integration into the tokamak. Requirements for operation and maintenance are outlined, and references to sources of additional information are provided.

NONE

1995-09-22T23:59:59.000Z

259

Assessment of solar options for small power systems applications. Volume II. Identification and characterization of concepts for analysis  

SciTech Connect (OSTI)

The primary purpose of this study is to provide DOE with an independent, objective assessment of the principal solar thermal conversion concepts that have the potential for achieving commercial success as small electric power sytems in the 1- to 10-MWe range. Seven generic types of collectors, together with associated subsystems for electric power generation, were considered in this study. The collectors can be classified into three categories: (1) two-axis tracking (with compound curvature reflecting surfaces); (2) one-axis tracking (with single-curvature reflecting surfaces); and (3) nontracking (with low-concentration reflecting surfaces). These collectors can be combined with energy transport, energy storage, and power conversion subsystems in a wide variety of ways to formulate conceptual systems for electric power generation. In this study, attention was restricted to configurations that are potentially suitable for development as small power systems (1 to 10 MWe) in the long term (1990 to 2000), with initial commercialization by the mid-1980s. Cogeneration and total energy systems were beyond the scope of this study. All seven types of collectors were analyzed in conceptual system configurations with Rankine-cycle engines. Because they can operate at particularly high concentration ratios, two of the collectors (the Point Focus Central Receiver and the Point Focus Distributed Receiver) were also analyzed with Brayton-cycle engines. In addition, the latter of the two was analyzed with Stirling-cycle engines. With these engine options, 10 conceptual systems were formulated for analysis. Results are presented in detail. (WHK)

Laity, W.W.; Aase, D.T.; Apley, W.J.; Bird, S.P.; Drost, M.K.; Williams, T.A.

1980-06-01T23:59:59.000Z

260

Test procedures and protocols: Their relevance to the figure of merit for thermal distribution systems. Volume 1: Informal report  

SciTech Connect (OSTI)

A conceptual framework is developed that categorizes measurement protocols for forced-air thermal distribution systems in small buildings. This framework is based on the distinction between two generic approaches. The {open_quote}system-comparison{close_quote} approach seeks to determine, via a pair of whole-house energy-use measurements, the difference in energy use between the house with the as-found duct system and the same house with no energy losses attributable to the thermal distribution system. The {open_quote}component loss-factor{close_quote} approach identifies and measures the individual causes of duct losses, and then builds up a value for the net overall duct efficiency, usually with the help of computer simulation. Examples of each approach are analyzed and related to a proposed Figure of Merit for thermal distribution systems. This Figure of Merit would serve as the basis for a Standard Method of Test analogous to those already in place for furnaces, boilers, air conditioners, and heat pumps.

Andrews, J.W.

1993-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Viability Assessment Volume 4  

SciTech Connect (OSTI)

Volume 4 provides the DOE plan and cost estimate for the remaining work necessary to proceed from completing this VA to submitting an LA to NRC. This work includes preparing an EIS and evaluating the suitability of the site. Both items are necessary components of the documentation required to support a decision in 2001 by the Secretary of Energy on whether or not to recommend that the President approve the site for development as a repository. If the President recommends the site to Congress and the site designation becomes effective, then DOE will submit the LA to NRC in 2002 for authorization to construct the repository. The work described in Volume 4 constitutes the last step in the characterization of the Yucca Mountain site and the design and evaluation of the performance of a repository system in the geologic setting of this site. The plans in this volume for the next 4 years' work are based on the results of the previous 15 years' work, as reported in Volumes 1, 2, and 3 of this VA. Volume 1 summarizes what DOE has learned to date about the Yucca Mountain site. Volume 2 describes the current, reference repository design, several design options that might enhance the performance of the reference design, and several alternative designs that represent substantial departures from the reference design. Volume 2 also summarizes the results of tests of candidate materials for waste packages and for support of the tunnels into which waste would be emplaced. Volume 3 provides the results of the latest performance assessments undertaken to evaluate the performance of the design in the geologic setting of Yucca Mountain. The results described in Volumes 1, 2, and 3 provide the basis for identifying and prioritizing the work described in this volume. DOE believes that the planned work, together with the results of previous work, will be sufficient to support a site suitability evaluation for site recommendation and, if the site is recommended and designated, a defensible LA. Volume 4 is divided into seven sections. Section 2 presents a rationale and summary for the technical work to be done to develop the preclosure and postclosure safety cases that will support the compliance evaluations required for the evaluation of site suitability and for licensing. Section 2 also describes other necessary technical work, including that needed to support design decisions and development of the necessary design information. Section 3 presents a more detailed description of the technical work required to address the issues identified in Section 2. Section 3 also describes activities that will continue after submittal of the site recommendation and the LA. Examples include the drift scale heater test in the Exploratory Studies Facility (Section 3.1.4.3) and long-term waste package corrosion testing (Section 3.2.2.9). Section 4 discusses the statutory and regulatory framework for site recommendation and submittal of an LA, and describes the activities and documentation that must be completed to achieve these milestones, including the development of an EIS. Section 5 describes the numerous activities required to support program milestones, including support for completing the testing program, continuing tests as part of the performance confirmation program, and managing information and records to support regulatory and legal review. Sections 6 and 7 provide cost and schedule information for the activities planned.

DOE

1998-12-01T23:59:59.000Z

262

Viability Assessment Volume 2  

SciTech Connect (OSTI)

This volume describes the major design features of the Monitored Geologic Repository. This document is not intended to provide an exhaustive, detailed description of the repository design. Rather, this document summarizes the major systems and primary elements of the design that are radiologically significant, and references the specific technical documents and design analyses wherein the details can be found. Not all portions of the design are at the same level of completeness. Highest priority has been given to assigning resources to advance the design of the Monitored Geologic Repository features that are important to radiological safety and/or waste isolation and for which there is no NRC licensing precedent. Those features that are important to radiological safety and/or waste isolation, but for which there is an NRC precedent, receive second priority. Systems and features that have no impact on radiological safety or waste isolation receive the lowest priority. This prioritization process, referred to as binning, is discussed in more detail in Section 2.3. Not every subject discussed in this volume is given equal treatment with regard to the level of detail provided. For example, less detail is provided for the surface facility design than for the subsurface and waste package designs. This different level of detail is intentional. Greater detail is provided for those functions, structures, systems, and components that play key roles with regard to protecting radiological health and safety and that are not common to existing nuclear facilities already licensed by NRC. A number of radiological subjects are not addressed in the VA, (e.g., environmental qualification of equipment). Environmental qualification of equipment and other radiological safety considerations will be addressed in the LA. Non-radiological safety considerations such as silica dust control and other occupational safety considerations are considered equally important but are not addressed in th is volume of the VA (see Volume 1, Section 2.2.1.2, subsection on Health Related Mineral Issues).

DOE

1998-12-01T23:59:59.000Z

263

The Coastal Ocean Prediction Systems program: Understanding and managing our coastal ocean. Volume 2: Overview and invited papers  

SciTech Connect (OSTI)

This document is a compilation of summaries of papers presented at the Coastal Ocean Prediction Systems workshop. Topics include; marine forecasting, regulatory agencies and regulations, research and application models, research and operational observing, oceanic and atmospheric data assimilation, and coastal physical processes.

Not Available

1990-05-15T23:59:59.000Z

264

River Protection Project Integrated safety management system phase II verification report, volumes I and II - 8/19/99  

SciTech Connect (OSTI)

The Department of Energy policy (DOE P 450.4) is that safety is integrated into all aspects of the management and operations of its facilities. In simple and straightforward terms, the Department will ''Do work safely.'' The purpose of this River Protection Project (RPP) Integrated Safety Management System (ISMS) Phase II Verification was to determine whether ISMS programs and processes are implemented within RFP to accomplish the goal of ''Do work safely.'' The goal of an implemented ISMS is to have a single integrated system that includes Environment, Safety, and Health (ES&H) requirements in the work planning and execution processes to ensure the protection of the worker, public, environment, and federal property over the RPP life cycle. The ISMS is comprised of the (1) described functions, components, processes, and interfaces (system map or blueprint) and (2) personnel who are executing those assigned roles and responsibilities to manage and control the ISMS. Therefore, this review evaluated both the ''paper'' and ''people'' aspects of the ISMS to ensure that the system is implemented within RPP. Richland Operations Office (RL) conducted an ISMS Phase I Verification of the TWRS from September 28-October 9, 1998. The resulting verification report recommended that TWRS-RL and the contractor proceed with Phase II of ISMS verification given that the concerns identified from the Phase I verification review are incorporated into the Phase II implementation plan.

SHOOP, D.S.

1999-09-10T23:59:59.000Z

265

International Journal of Computer Information Systems and Industrial Management Applications. ISSN 2150-7988 Volume 3 (2011), pp. 812819  

E-Print Network [OSTI]

International Journal of Computer Information Systems and Industrial Management Applications. ISSN functions reduce the differences between high color levels in comparison to middle color levels that re light intensities, and assigned the hue and sat- uration values of saturated (r,g,b) triplets according

Werman, Michael

266

Technical and economic assessment of fluidized-bed-augmented compressed-air energy-storage system. Volume I. Executive summary  

SciTech Connect (OSTI)

An energy storage system which could be attractive for future electric utility peak-load applications is a modified gas turbine power system utilizing underground storage of very high pressure air. The compressed air energy storage (CAES) concept involves using off-peak electricity generated from indigenous coal or nuclear sources to compress air, storing the air in large underground facilities, and withdrawing the air during peak-load periods when it would be heated by combustion and expanded through gas turbines to generate power. The attractiveness of the CAES concept is based upon its potential to supply competitively priced peaking energy, to reduce peak-load power plant dependence on petroleum-based fuels, and to provide a means for leveling the utility system load demand. Therefore, a technical and economic assessment of coal-fired fluidized bed (FBC) combustor/compressed air energy storage (FBC/CAES) systems was performed and is described. The conclusions drawn from the FBC/CAES study program are encouraging. They indicate that pressurized FBC/CAES power plants should be technologically feasible, provide good performance, and be economically competitive. Specifically, it is concluded that: coal-fired FBC/CAES systems should be technically feasible in the near future and potentially attractive for peak-load power generation; and an open-bed PFBC/CAES configuration would provide the best candidate for early commercialization. It has relatively low risk combined with moderate cost and reasonable round-trip heat rate. It also has the potential for future growth options which tend to reduce costs and lower fuel consumption.

Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

1981-09-01T23:59:59.000Z

267

RENEL-Romanian SCADA/EMS and communications systems project, definitional mission. Export trade information. Volume 1  

SciTech Connect (OSTI)

The Romanian Electricity Board (RENEL), which is Romania's electric utility, requested the U.S. Trade and Development Program (TDP) to fund a feasibility study for the modernization of the energy management system (EMS) at the three levels of operations management hierarchy: national, regional and 'enterprise' (district). A Definitional Mission (DM) to Romania recommends that the TDP fund the requested feasibility study for the following reasons: Romania's EMS/SCADA and communications system needs modernization; There is a commitment within RENEL to carry out this modernization program as a matter of high priority; The procurement is financeable subject to a thorough feasibility study; and There is an opportunity for U.S. business to supply goods and services during the subsequent procurement phase.

Thayer, J.

1992-05-01T23:59:59.000Z

268

Risk-based systems analysis of emerging high-level waste tank remediation technologies. Volume 2: Final report  

SciTech Connect (OSTI)

The objective of DOE`s Radioactive Waste Tank Remediation Technology Focus Area is to identify and develop new technologies that will reduce the risk and/or cost of remediating DOE underground waste storage tanks and tank contents. There are, however, many more technology investment opportunities than the current budget can support. Current technology development selection methods evaluate new technologies in isolation from other components of an overall tank waste remediation system. This report describes a System Analysis Model developed under the US Department of Energy (DOE) Office of Technology Development (OTD) Underground Storage Tank-Integrated Demonstration (UST-ID) program. The report identifies the project objectives and provides a description of the model. Development of the first ``demonstration`` version of this model and a trial application have been completed and the results are presented. This model will continue to evolve as it undergoes additional user review and testing.

Peters, B.B.; Cameron, R.J.; McCormack, W.D. [Enserch Environmental Corp., Richland, WA (United States)

1994-08-01T23:59:59.000Z

269

Solar power satellite antenna phase control system hardware simulation, phase 4. Volume 3: SOLARSIM users manual. Final report  

SciTech Connect (OSTI)

Documentation of the interactive software package designed to predict the effect of certain electrical and mechanical imperfections on the performance of the SPS system is presented. The capabilities of the SOLARSIM program to quantify the spacetenna performance parameter values are described. The SOLARSIM package can compute the RMS pointing error, title effects, MPTX code tracking loop performance, MPTX carrier tracking loop performance, averaged power pattern, and the power transfer efficiency.

Lindsey, W.C.; Kantak, A.V.; Chie, C.M.

1981-03-01T23:59:59.000Z

270

Waste Isolation Pilot Plant shaft sealing system compliance submittal design report. Volume 2 of 2: Appendix E  

SciTech Connect (OSTI)

This report describes a shaft sealing design for the Waste Isolation Pilot Plant (WIPP), a proposed nuclear waste repository in bedded salt. The system is designed to limit entry of water and release of contaminants through the four existing shafts after the WIPP is decommissioned. The design approach applies redundancy to functional elements and specifies multiple, common, low-permeability materials to reduce uncertainty in performance. The system comprises 13 elements that completely fill the shafts with engineered materials possessing high density and low permeability. Laboratory and field measurements of component properties and performance provide the basis for the design and related evaluations. Hydrologic, mechanical, thermal, and physical features of the system are evaluated in a series of calculations. These evaluations indicate that the design guidance is addressed by effectively limiting transport of fluids within the shafts, thereby limiting transport of hazardous material to regulatory boundaries. Additionally, the use or adaptation of existing technologies for placement of the seal components combined with the use of available, common materials assure that the design can be constructed.

NONE

1996-08-01T23:59:59.000Z

271

SMACS: a system of computer programs for probabilistic seismic analysis of structures and subsystems. Volume I. User's manual  

SciTech Connect (OSTI)

The SMACS (Seismic Methodology Analysis Chain with Statistics) system of computer programs, one of the major computational tools of the Seismic Safety Margins Research Program (SSMRP), links the seismic input with the calculation of soil-structure interaction, major structure response, and subsystem response. The seismic input is defined by ensembles of acceleration time histories in three orthogonal directions. Soil-structure interaction and detailed structural response are then determined simultaneously, using the substructure approach to SSI as implemented in the CLASSI family of computer programs. The modus operandi of SMACS is to perform repeated deterministic analyses, each analysis simulating an earthquake occurrence. Parameter values for each simulation are sampled from assumed probability distributions according to a Latin hypercube experimental design. The user may specify values of the coefficients of variation (COV) for the distributions of the input variables. At the heart of the SMACS system is the computer program SMAX, which performs the repeated SSI response calculations for major structure and subsystem response. This report describes SMAX and the pre- and post-processor codes, used in conjunction with it, that comprise the SMACS system. (ACR)

Maslenikov, O.R.; Johnson, J.J.; Tiong, L.W.; Mraz, M.J.; Bumpus, S.; Gerhard, M.A.

1985-03-01T23:59:59.000Z

272

The design, construction, and monitoring of photovoltaic power system and solar thermal system on the Georgia Institute of Technology Aquatic Center. Volume 1  

SciTech Connect (OSTI)

This is a report on the feasibility study, design, and construction of a PV and solar thermal system for the Georgia Tech Aquatic Center. The topics of the report include a discussion of site selection and system selection, funding, design alternatives, PV module selection, final design, and project costs. Included are appendices describing the solar thermal system, the SAC entrance canopy PV mockup, and the PV feasibility study.

Long, R.C.

1996-12-31T23:59:59.000Z

273

District heating and cooling systems for communities through power plant retrofit distribution network, Phase 2. Final report, 1 March 1980-31 January 1984. Volume II  

SciTech Connect (OSTI)

This volume begins with an Introduction summarizing the history, methodology and scope of the study, the project team members and the private and public groups consulted in the course of the study. The Load and Service Area Assessment follows, including: a compilation and analysis of existing statistical thermal load data from census data, industrial directories, PSE and G records and other sources; an analysis of responses to a detailed, 4-page thermal load questionnaire; data on public buildings and fuel and energy use provided by the New Jersey Dept. of Energy; and results of other customer surveys conducted by PSE and G. A discussion of institutional questions follows. The general topic of rates is then discussed, including a draft hypothetical Tariff for Thermal Services. Financial considerations are discussed including a report identifying alternative ownership/financing options for district heating systems and the tax implications of these options. Four of these options were then selected by PSE and G and a financial (cash-flow) analysis done (by the PSE and G System Planning Dept.) in comparison with a conventional heating alternative. Year-by-year cost of heat ($/10/sup 6/ Btu) was calculated and tabulated, and the various options compared.

Not Available

1984-01-31T23:59:59.000Z

274

Field test of two high-pressure direct-contact downhole steam generators. Volume II. Oxygen/diesel system  

SciTech Connect (OSTI)

A field test of an oxygen/diesel fuel, direct contact steam generator has been completed. The field test, which was a part of Project DEEP STEAM and was sponsored by the US Department of Energy, involved the thermal stimulation of a well pattern in the Tar Zone of the Wilmington Oil Field. The activity was carried out in cooperation with the City of Long Beach and the Long Beach Oil Development Company. The steam generator was operated at ground level, with the steam and combustion products delivered to the reservoir through 2022 feet of calcium-silicate insulated tubing. The objectives of the test included demonstrations of safety, operational ease, reliability and lifetime; investigations of reservoir response, environmental impact, and economics; and comparison of those points with a second generator that used air rather than oxygen. The test was extensively instrumented to provide the required data. Excluding interruptions not attributable to the oxygen/diesel system, steam was injected 78% of the time. System lifetime was limited by the combustor, which required some parts replacement every 2 to 3 weeks. For the conditions of this particular test, the use of trucked-in LOX resulted in liess expense than did the production of the equivalent amount of high pressure air using on site compressors. No statistically significant production change in the eight-acre oxygen system well pattern occurred during the test, nor were any adverse effects on the reservoir character detected. Gas analyses during the field test showed very low levels of SOX (less than or equal to 1 ppM) in the generator gaseous effluent. The SOX and NOX data did not permit any conclusion to be drawn regarding reservoir scrubbing. Appreciable levels of CO (less than or equal to 5%) were measured at the generator, and in this case produced-gas analyses showed evidence of significant gas scrubbing. 64 figures, 10 tables.

Moreno, J.B.

1983-07-01T23:59:59.000Z

275

Screening study for evaluation of the potential for system 80+ to consume excess plutonium - Volume 1. Final report  

SciTech Connect (OSTI)

As part of the U.S. effort to evaluate technologies offering solutions for the safe disposal or utilization of surplus nuclear materials, the fiscal year 1993 Energy and Water Appropriations legislation provided the Department of Energy (DOE) the necessary funds to conduct multi-phased studies to determine the technical feasibility of using reactor technologies for the triple mission of burning weapons grade plutonium, producing tritium for the existing smaller weapons stockpile, and generating commercial electricity. DOE limited the studies to five advanced reactor designs. Among the technologies selected is the ABB-Combustion Engineering (ABB-CE) System 80+. The DOE study, currently in Phase ID, is proceeding with a more detailed evaluation of the design`s capability for plutonium disposition.

Not Available

1994-04-30T23:59:59.000Z

276

Screening study for evaluation of the potential for system 80+ to consume excess plutonium - Volume 2. Final report  

SciTech Connect (OSTI)

As part of the U.S. effort to evaluate technologies offering solutions for the safe disposal or utilization of surplus nuclear materials, the fiscal year 1993 Energy and Water Appropriations legislation provided the Department of Energy (DOE) the necessary funds to conduct multi-phased studies to determine the technical feasibility of using reactor technologies for the triple mission of burning weapons grade plutonium, producing tritium for the existing smaller weapons stockpile, and generating commercial electricity. DOE limited the studies to five advanced reactor designs. Among the technologies selected is the ABB-Combustion Engineering (ABB-CE) System 80+. The DOE study, currently in Phase ID, is proceeding with a more detailed evaluation of the design`s capability for plutonium disposition.

Not Available

1994-04-30T23:59:59.000Z

277

Tank Waste Remediation System fiscal year 1996 multi-year program plan WBS 1.1. Revision 1, Volume 1  

SciTech Connect (OSTI)

The 1995 Hanford Mission Plan specifically addresses the tank waste issue and clarifies the link with other initiatives, such as improving management practices and the Hanford Site Waste Minimization and Pollution Prevention Awareness Program Plan (DOE/RL-91-31). This document captures the results of decision making regarding the application of systems engineering at the Hanford Site, external involvement policy, and site end-state goals. Section 3.5 of the Hanford Mission Plan on Decisions and Directives provides an integrating discussion of the actions of the National Environmental Policy Act (NEPA), and DOE policy, guidance, and decisions associated with binding agreements such as the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement). Two significant components of the Hanford Mission Plan 1994 planning basis are (1) the decisions regarding the disposition of onsite material inventory, and the key programs and interfaces to accomplish this; and (2) the Program Interface Issues section, which identified issues that stretch across program boundaries.

NONE

1995-09-01T23:59:59.000Z

278

Lower Flathead System Fisheries Study, South Bay of Flathead Lake, Volume III, 1983-1987 Final Report.  

SciTech Connect (OSTI)

The Lower Flathead System Fisheries Study assessed the effects of Kerr Dam operation on the fisheries of the lower Flathead ecosystem. South Bay, the southern most lobe of Flathead Lake, is the most extensive area of shallow water, and therefore, most effected by changes in lake levels. This study began in January of 1984 and was completed in early 1987. Vegetative and structural cover are relatively limited in South Bay, a condition which could contribute to lower recruitment for some fish species. Our data show that the study area contained 0.04% structural and 5.4% vegetative cover in June at full pool. Both figures are less than 1.0% at minimum pool. Structural complexity mediates the ecological interactions between littoral zone fish and their prey, and can affect local productivity and growth in fish. Structural complexity may also be important to overwinter survival of young perch in Flathead Lake. Winter conditions, including ice cover and fall drawdown, seasonally eliminate the vegetative portion of most rooted macrophytes in South Bay. This results in substantial loss of what little structural cover exists, depriving the perch population of habitat which has been occupied all summer. The loss of cover from draw-down concentrates and probably exposes perch to greater predation, including cannibalism, than would occur if structural complexity were greater. 33 refs., 10 figs., 5 tabs.

Cross, David; Waite, Ian

1988-06-01T23:59:59.000Z

279

Home energy rating system building energy simulation test (HERS BESTEST): Volume 1, Tier 1 and Tier 2 tests user's manual  

SciTech Connect (OSTI)

The Home Energy Rating System (HERS) Building Energy Simulation Test (BESTEST) is a method for evaluating the credibility of software used by HERS to model energy use in buildings. The method provides the technical foundation for ''certification of the technical accuracy of building energy analysis tools used to determine energy efficiency ratings,'' as called for in the Energy Policy Act of 1992 (Title I, subtitle A,l Section 102, Title II, Part 6, Section 271). Certification is accomplished with a uniform set of test cases that facilitate the comparison of a software tool with several of the best public-domain, state-of-the-art building energy simulation programs available in the United States. This set of test cases represents the Tier 1 and Tier 2 Tests for Certification of Rating Tools as described in DOE 10 CFR Part 437 and the HERS Council Guidelines for Uniformity (HERS Council). A third Tier of tests not included in this document is also planned.

Judkoff, R.; Neymark, J.

1995-11-01T23:59:59.000Z

280

Evaluation of nuclear facility decommissioning projects. Three Mile Island Unit 2 reactor coolant system and systems decontamination. Summary status report. Volume 1  

SciTech Connect (OSTI)

This document summarizes information relating to the decontamination and restoration of the Three Mile Island Unit 2 reactor coolant system and other plant systems. Data have been collected from activity reports, reactor containment entry records, and other sources and entered in a computerized data system which permits extraction/manipulation of specific data which can be used in planning for recovery from a loss of coolant event similar to that experienced by the Three Mile Island Unit 2 on March 28, 1979. This report contains a summary of radiation exposures, manpower, and time spent in radiation areas during the referenced period. Support activities conducted outside of radiation areas are not included. Computer reports included are: A chronological listing of all activities related to decomtamination and restoration of the reactor coolant system and other plant systems for the period of April 5, 1979, through December 19, 1984; a summary of labor and exposures by department for the same time period; and summary reports for each major task undertaken in connection with this specific work scope during the referenced time period.

Doerge, D.H.; Miller, R.L.; Scotti, K.S.

1986-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Field test of two high-pressure, direct-contact downhole steam generators. Volume I. Air/diesel system  

SciTech Connect (OSTI)

As a part of the Project DEEP STEAM to develop technology to more efficiently utilize steam for the recovery of heavy oil from deep reservoirs, a field test of a downhole steam generator (DSG) was performed. The DSG burned No. 2 diesel fuel in air and was a direct-contact, high pressure device which mixed the steam with the combustion products and injected the resulting mixture directly into the oil reservoir. The objectives of the test program included demonstration of long-term operation of a DSG, development of operational methods, assessment of the effects of the steam/combustion gases on the reservoir and comparison of this air/diesel DSG with an adjacent oxygen/diesel direct contact generator. Downhole operation of the air/diesel DSG was started in June 1981 and was terminated in late February 1982. During this period two units were placed downhole with the first operating for about 20 days. It was removed, the support systems were slightly modified, and the second one was operated for 106 days. During this latter interval the generator operated for 70% of the time with surface air compressor problems the primary source of the down time. Thermal contact, as evidenced by a temperature increase in the production well casing gases, and an oil production increase were measured in one of the four wells in the air/diesel pattern. Reservoir scrubbing of carbon monoxide was observed, but no conclusive data on scrubbing of SO/sub x/ and NO/sub x/ were obtained. Corrosion of the DSG combustor walls and some other parts of the downhole package were noted. Metallurgical studies have been completed and recommendations made for other materials that are expected to better withstand the downhole combustion environment. 39 figures, 8 tables.

Marshall, B.W.

1983-05-01T23:59:59.000Z

282

Process system evaluation-consolidated letters. Volume 1. Alternatives for the off-gas treatment system for the low-level waste vitrification process  

SciTech Connect (OSTI)

This report provides an evaluation of alternatives for treating off-gas from the low-level waste (LLW) melter. The study used expertise obtained from the commercial nonradioactive off-gas treatment industry. It was assumed that contact maintenance is possible, although the subsequent risk to maintenance personnel was qualitatively considered in selecting equipment. Some adaptations to the alternatives described may be required, depending on the extent of contact maintenance that can be achieved. This evaluation identified key issues for the off-gas system design. To provide background information, technology reviews were assembled for various classifications of off-gas treatment equipment, including off-gas cooling, particulate control, acid gas control, mist elimination, NO{sub x} reduction, and SO{sub 2} removal. An order-of-magnitude cost estimate for one of the off-gas systems considered is provided using both the off-gas characteristics associated with the Joule-heated and combustion-fired melters. The key issues identified and a description of the preferred off-gas system options are provided below. Five candidate treatment systems were evaluated. All of the systems are appropriate for the different melting/feed preparations currently being considered. The lowest technical risk is achieved using option 1, which is similar to designs for high-level waste (HLW) vitrification in the Hanford Waste Vitrification Project (HWVP) and the West Valley. Demonstration Project. Option 1 uses a film cooler, submerged bed scrubber (SBS), and high-efficiency mist eliminator (HEME) prior to NO{sub x} reduction and high-efficiency particulate air (HEPA) filtration. However, several advantages were identified for option 2, which uses high-temperature filtration. Based on the evaluation, option 2 was identified as the preferred alternative. The characteristics of this option are described below.

Peurrung, L.M.; Deforest, T.J; Richards, J.R.

1996-03-01T23:59:59.000Z

283

The second iteration of the Systems Prioritization Method: A systems prioritization and decision-aiding tool for the Waste Isolation Pilot Plant: Volume 3, Analysis for final programmatic recommendations  

SciTech Connect (OSTI)

Systems Prioritization Method (SPM) is a decision-aiding tool developed by Sandia National Laboratories for the US DOE Carlsbad Area Office (DOE/CAO). This tool provides an analytical basis for programmatic decision making for the Waste Isolation Pilot Plant (WIPP). SPM integrates decision-analysis techniques, performance,a nd risk-assessment tools, and advanced information technology. Potential outcomes of proposed activities and combination of activities are used to calculate a probability of demonstrating compliance (PDC) with selected regulations. The results are presented in a decision matrix showing cost, duration, and maximum PDC for all activities in a given cost and duration category. This is the third and final volume in the series which presents the analysis for final programmatic recommendations.

Prindle, N.H.; Boak, D.M.; Weiner, R.F. [and others] [and others

1996-05-01T23:59:59.000Z

284

District heating and cooling systems for communities through power plant retrofit distribution network, Phase 2. Final report, March 1, 1980-January 31, 1984. Volume 5, Appendix A  

SciTech Connect (OSTI)

This volume contains the backup data for the portion of the load and service assessment in Section 2, Volume II of this report. This includes: locations of industrial and commercial establishments, locations of high rise buildings, data from the Newark (Essex County) Directory of Business, data from the Hudson County Industrial Directory, data from the N. J. Department of Energy Inventory of Public Buildings, data on commercial and industrial establishments and new developments in the Hackensack Meadowlands, data on urban redevelopment and Operation Breakthrough, and list of streets in the potential district heating areas of Newark/Harrison and Jersey City/Hoboken.

Not Available

1984-01-31T23:59:59.000Z

285

Computer News, Volume 3  

E-Print Network [OSTI]

[mandelbrot set] MATH DEPT Computer News, Volume 3. How to take advantage of the newer, faster machines on our network ...

286

Computer News, Volume 2  

E-Print Network [OSTI]

[mandelbrot set] MATH DEPT Computer News, Volume 2. How to handle .pdf files on the web: acroread, distill, and Netscape ...

287

Preliminary design study of compressed-air energy storage in a salt dome. Volume 5. System, subsystem, and component design approach. Final report  

SciTech Connect (OSTI)

The approach to system, subsystem, and component design for a compressed-air energy storage (CAES) plant located in the Middle South Services, Inc., is presented in this final report. The design approach is based on the facility design criteria described in Volume 2 and the site conditions at the Carmichael salt dome located near Jackson, Mississippi. For the selected weekly cycle, Brown Boveri Corporation selected a single-casing design of fired-high-power and fired-low-power turbines. The high-power (HP) turbine operates at inlet conditions of 609.2 psia (42 bar) and 1021.4/sup 0/F (550/sup 0/C), while the low-power (LP) turbine operates at 159.5 psia (11 bar) and 1633.4/sup 0/F (890/sup 0/C). A tubular design of exhaust gas recuperator heats the incoming air from the storage cavern from 138.4/sup 0/F (60/sup 0/C) to 692/sup 0/F (367/sup 0/C). The compressor design is a single-shaft, tandem-compound arrangement with a 3600-rpm LP compressor and a 6850-rpm HP compressor. The LP compressor is a combination six-stage axial, three-stage radial compressor with an integral cooler and diffuser built into the casing. The HP compressor is a five-stage radial compressor with external intercooler provided after both the second and fourth stages. Fenix and Scisson, Inc., selected two half-size air storage caverns, each capable of delivering full-turbine air mass flow. A solutioning rate of 1750 gpm will allow completion of both caverns without prolonging construction schedule. Fuel is No. 2 distillate, which is delivered on a weekly basis. Rather than construct a rail siding to the plant, a trade-off study showed it more economical to pump the fuel oil to the CAES plant through a seven-mile buried pipeline from the nearest existing rail line. The exhaust gas recuperator, synchronous clutches, and gear case between the HP and LP compressors are key components which require special attention in design and fabrication to ensure reliable CAES plant operation.

Not Available

1982-04-01T23:59:59.000Z

288

District heating and cooling systems for communities through power plant retrofit distribution network. Phase 2. Final report, 1 March 1980-31 January 1984. Volume VII. Appendix C  

SciTech Connect (OSTI)

This volume contains: Hudson No. 2 Limited Retrofit Cost Estimates provided by Stone and Webster Engineering Corp. (SWEC); backup data and basis of estimate for SWEC Heater Plant and Gas Turbine Plant (Kearny No. 12) cost estimates; and Appendices - Analysis of Relevant Tax Laws.

Not Available

1984-01-31T23:59:59.000Z

289

District heating and cooling systems for communities through power plant retrofit distribution network. Phase 2. Final report, March 1, 1980-January 31, 1984. Volume IV  

SciTech Connect (OSTI)

This volume contains the following: discussion of cost estimating methodology, detailed cost estimates of Hudson No. 2 retrofit, intermediate thermal plant (Kearny No. 12) and local heater plants; transmission and distribution cost estimate; landfill gas cost estimate; staged development scenarios; economic evaluation; fuel use impact; air quality impact; and alternatives to district heating.

Not Available

1984-01-31T23:59:59.000Z

290

Site Environmental Report for 2005 Volume I and Volume II  

SciTech Connect (OSTI)

Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, ''Environment, Safety, and Health Reporting''. The ''Site Environmental Report for 2005'' summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2005. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab'', ''the Laboratory'', ''Lawrence Berkeley National Laboratory'', and ''LBNL''.) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. This year's Volume I text body is organized into an executive summary followed by six chapters. The report's structure has been reorganized this year, and it now includes a chapter devoted to environmental management system topics. Volume II contains individual data results from surveillance and monitoring activities. The ''Site Environmental Report'' is distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current regulatory standards and is more familiar to some readers. Two tables are provided at the end of the Glossary to help readers: the first defines the prefixes used with SI units of measurement, and the second provides conversions to non-SI units.

Ruggieri, Michael

2006-07-07T23:59:59.000Z

291

VolumeExplorer: Roaming Large Volumes to Couple Visualization and Data Processing for Oil and Gas Exploration  

E-Print Network [OSTI]

VolumeExplorer: Roaming Large Volumes to Couple Visualization and Data Processing for Oil and Gas dedicated to oil and gas exploration. Our system combines probe- based volume rendering with data processing Seismic interpretation is an important task in the oil and gas exploration-production (EP) workflow [9, 26

Paris-Sud XI, Université de

292

E-Print Network 3.0 - air volume air Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Use Summary: pressure, and for modeling the change in system pressure as function of compressed air storage volume... important system variables such as system pressure and...

293

IEA Wind Task 24 Integration of Wind and Hydropower Systems; Volume 1: Issues, Impacts, and Economics of Wind and Hydropower Integration  

SciTech Connect (OSTI)

This report describes the background, concepts, issues and conclusions related to the feasibility of integrating wind and hydropower, as investigated by the members of IEA Wind Task 24. It is the result of a four-year effort involving seven IEA member countries and thirteen participating organizations. The companion report, Volume 2, describes in detail the study methodologies and participant case studies, and exists as a reference for this report.

Acker, T.

2011-12-01T23:59:59.000Z

294

A study of toxic emissions from a coal-fired power plant utilizing an ESP/Wet FGD system. Volume 1, Sampling, results, and special topics: Final report  

SciTech Connect (OSTI)

This was one of a group of assessments of toxic emissions from coal-fired power plants, conducted for DOE-PETC in 1993 as mandated by the 1990 Clean Air Act. It is organized into 2 volumes; Volume 1 describes the sampling effort, presents the concentration data on toxic chemicals in several power plant streams, and reports the results of evaluations and calculations. The study involved solid, liquid, and gaseous samples from input, output, and process streams at Coal Creek Station Unit No. 1, Underwood, North Dakota (1100 MW mine-mouth plant burning lignite from the Falkirk mine located adjacent to the plant). This plant had an electrostatic precipitator and a wet scrubber flue gas desulfurization unit. Measurements were conducted on June 21--24, 26, and 27, 1993; chemicals measured were 6 major and 16 trace elements (including Hg, Cr, Cd, Pb, Se, As, Be, Ni), acids and corresponding anions (HCl, HF, chloride, fluoride, phosphate, sulfate), ammonia and cyanide, elemental C, radionuclides, VOCs, semivolatiles (incl. PAH, polychlorinated dioxins, furans), and aldehydes. Volume 2: Appendices includes process data log sheets, field sampling data sheets, uncertainty calculations, and quality assurance results.

Not Available

1994-07-01T23:59:59.000Z

295

Utility Cost Analysis  

E-Print Network [OSTI]

W Computere 6 Computer HVAC Computers Liebert Unite CRT's Subtotal WAC System VAV AHU' s TABLE 3: OPERATING kW BY SEASON Computers 6 Computer WAC Comput err Liebert Unitr CRT'B Sub total HVAC System VAV AHU's AHU1# Pumps Chillerr Subtotal...

Horn, S.

1984-01-01T23:59:59.000Z

296

Peng Xu and Philip Haves Ernest Orlando Lawrence Berkeley National Laboratory  

E-Print Network [OSTI]

in the cooling coil subsystem of an air handling unit. McIntosh et al. (2000) developed a mechanical model Testing of Component-Level Model-Based Fault Detection Methods for Mixing Boxes and VAV Fan Systems-Level Model-Based Fault Detection Methods for Mixing Boxes and VAV Fan Systems Peng Xu and Philip Haves

297

LANL Volume 2_Final  

Broader source: Energy.gov (indexed) [DOE]

42 LANL * Consider developing programmatic evaluation criteria based on the October 1999 draft of Volume VI, Emergency Management Evaluations, of the DOE emergency...

298

Finite Volume Element Method  

E-Print Network [OSTI]

FVE is closely related to the control volume finite element method ... simple stencils, to apply to a fairly wide range of fluid flow equations, to effectively treat.

2003-12-06T23:59:59.000Z

299

Computer News, Volume 25  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 25. TeX for Mac OS X. plus ssh and security issues for Macs. by Rodrigo Bańuelos. NOTE: These instructions are now ...

300

Computer News, Volume 1  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 1. You and your .cshrc file. Click on RELOAD now. This page is frequently updated and you might be looking at an old ...

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Computer News, Volume 36  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 36. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

302

Computer News, Volume 19  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 19. Those damned attachments! I explain here how to extract and decode e-mail attachments of various kinds. Click on ...

303

Computer News, Volume 8  

E-Print Network [OSTI]

[mandelbrot set] MATH DEPT Computer News, Volume 8. A convenient way to do e-mail from home. by guest columnist, Donu Arapura ...

304

Computer News, Volume 20  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 20. You and your .forward file. Let's say your name is Steven Bellisandagorapahockey and your login id on math is sbellis ...

305

Computer News, Volume 37  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 37. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

306

Computer News, Volume 13  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 13. How to dork your official classlist. Click on RELOAD now. This page is frequently updated and you might be looking at ...

307

Computer News, Volume 15  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 15. How to gain access to Mathematica on a math dept SUN. Click on RELOAD now. This page is frequently updated and ...

308

Computer News, Volume 34  

E-Print Network [OSTI]

[mandelbrot set] MATH DEPT Computer News, Volume 34. Click on RELOAD now. This page is frequently updated and you might be looking at an old version

309

Computer News, Volume 33  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 33. How I teach big calculus lectures with a tablet PC. Click on RELOAD now. This page is frequently updated and you ...

310

Computer News, Volume 12  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 12. Quick and dirty math on the internet. Click on RELOAD now. This page is frequently updated and you might be ...

311

Computer News, Volume 38  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 38. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

312

Computer News, Volume 27  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 27. How to approve Plans of Study on the web. First, make sure you know your Purdue Career Account Login and ...

313

Computer News, Volume 4  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 4. Xess, the spreadsheet. Click on RELOAD now. This page is frequently updated and you might be looking at an old ...

314

Computer News, Volume 2  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 2. How to add acroread and distill to your path. Click on RELOAD now. This page is frequently updated and you might be ...

315

Computer News, Volume 35  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 34. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

316

Computer News, Volume 32  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 32. The new TeX and how to create the new PU Math letterhead stationery. with help from Brad Lucier, Rodrigo Bańuelos

317

Computer News, Volume 39  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 39. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

318

Computer News, Volume 23  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 23. How to view e-mail formatted in HTML originating from the web. Click on RELOAD now. This page is frequently ...

319

Prime Supplier Sales Volumes  

Gasoline and Diesel Fuel Update (EIA)

Sales Volumes of Motor Gasoline by Grade, Formulation, PAD District, and State 356 Energy Information Administration Petroleum Marketing Annual 1996 Table 48. Prime...

320

Prime Supplier Sales Volumes  

Gasoline and Diesel Fuel Update (EIA)

Sales Volumes of Motor Gasoline by Grade, Formulation, PAD District, and State 356 Energy Information Administration Petroleum Marketing Annual 1997 Table 48. Prime...

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Educing the volume out of the phase space boundary  

E-Print Network [OSTI]

We explicitly show that, in a system with T-duality symmetry, the configuration space volume degrees of freedom may hide on the surface boundary of the region of accessible states with energy lower than a fixed value. This means that, when taking the decompactification limit (big volume limit), a number of accessible states proportional to the volume is recovered even if no volume dependence appears when energy is high enough. All this behavior is contained in the exact way of computing sums by making integrals. We will also show how the decompactification limit for the gas of strings can be defined in a microcanonical description at finite volume.

Manuel A. Cobas; M. A. R. Osorio; María Suárez

2005-09-26T23:59:59.000Z

322

Site Environmental Report for 2002, Volume 1  

SciTech Connect (OSTI)

Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1. The ''Site Environmental Report for 2002'' summarizes Berkeley Lab's compliance with environmental standards and requirements, characterizes environmental management efforts through surveillance and monitoring activities, and highlights significant programs and efforts for calendar year 2002. Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab,'' ''the Laboratory,'' ''Lawrence Berkeley National Laboratory,'' and ''LBNL.'' The report is separated into two volumes. Volume I contains a general overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. Volume II contains individual data results from the monitoring programs. This year, the ''Site Environmental Report'' was distributed on a CD in PDF format that includes Volume I, Volume II, and related documents. The report is also available on the Web at http://www.lbl.gov/ehs/esg/. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are additionally reported using the more conventional (non-SI) system of measurements because this system is referenced by some current regulatory standards and is more familiar to some readers. The tables included at the end of the Glossary are intended to help readers understand the various prefixes used with SI units of measurement and convert these units from one system to the other.

Pauer, Ron

2003-07-01T23:59:59.000Z

323

ENERGY LEVEL SPECTROSCOPY OF A BOUND VORTEX-ANTIVORTEX PAIR  

E-Print Network [OSTI]

vortex- antivortex (VAV) state in an annular Josephson junction. The bound VAV pair is formed microwave spectroscopy. Keywords: Macroscopic quantum effects, long Josephson junctions, vortex­9]. Most of the studied systems, such as dc-biased Josephson junctions (JJ), supercon- ducting quantum

Wallraff, Andreas

324

Full-scale incineration-system demonstration at the Naval Battalion Construction Center, Gulfport, Mississippi. volume 8. delisting. Final report, Sep 86-Feb 89  

SciTech Connect (OSTI)

Volume VIII documents the regulatory and technical lessons learned concerning disposition of soil after treatment. The report also documents the data collected in support of soil disposition. It explains EPA's use of the Vertical Horizontal Spread/Organic Leachate Model (VHS/OLM) to show the health risk of a hazardous waste site. Field operations and subsequent analyses were undertaken to support delisting of the soil, including the verification test burn, a RCRA trial burn, and data collected during routine operations. Conclusions are presented that can be drawn from the delisting process. It examines problems with EPA's Practical Quantitation Limits and VHS/OLM, the cost and level of effort, the technical complexity, the required concentrations needed for delisting, and the Air Force response to EPA's implied delisting denial. Six recommendations are offered to anyone considering submission of a delisting petition for a hazardous waste.

Haley, D.J.

1991-07-01T23:59:59.000Z

325

Twenty-First Water Reactor Safety Information Meeting. Volume 3, Primary system integrity; Aging research, products and applications; Structural and seismic engineering; Seismology and geology: Proceedings  

SciTech Connect (OSTI)

This three-volume report contains 90 papers out of the 102 that were presented at the Twenty-First Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, during the week of October 25-27, 1993. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Germany, Japan, Russia, Switzerland, Taiwan, and United Kingdom. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. Selected papers were indexed separately for inclusion in the Energy Science and Technology Database.

Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)] [comp.; Brookhaven National Lab., Upton, NY (United States)

1994-04-01T23:59:59.000Z

326

Computer News, Volume 29  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 29. How to update your login shell from csh to tcsh. If you, like me, have had an account on the Math network of SUNs ...

327

Computer News, Volume 30  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 30. How to create an ASCII version of the Purdue Logo and other matters of e-mail etiquette. The Purdue logo... ... ah, yes ...

328

Computer News, Volume 26  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 26. How to trim an e-mail alias. The faculty e-mail alias has a lot more people on it than you might imagine. (To find out ...

329

Computer News, Volume 7  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 7. How to put figures in TeX. (I assume that you are using X windows on or from a math dept SUN.) To make a figure, I use ...

330

Computer News, Volume 31  

E-Print Network [OSTI]

MATH DEPT Computer News, Volume 31. How to create .pdf files from TeX. by Donu Arapura. Click on RELOAD now. This page is frequently updated and you ...

331

Imaging using volume holograms  

E-Print Network [OSTI]

Volume holograms can be thought of as self-aligned 3D stacks of diffractive elements that operate coherently on incident fields as they propagate through the structure. In this thesis, we propose, design and implement ...

Sinha, Arnab, 1978-

2004-01-01T23:59:59.000Z

332

Development of standardized air-blown coal gasifier/gas turbine concepts for future electric power systems. Volume 1, Final report  

SciTech Connect (OSTI)

The objective of this study is to develop standardized air blown fixed bed gasification hot gas cleanup integrated gasifier combined cycle (IGCC) systems.

Sadowski, R.S.; Brown, M.J.; Hester, J.C.; Harriz, J.T.; Ritz, G.J.

1991-02-01T23:59:59.000Z

333

User manual for GEOCITY: a computer model for cost analysis of geothermal district-heating-and-cooling systems. Volume I. Main text  

SciTech Connect (OSTI)

The purpose of this model is to calculate the costs of residential space heating, space cooling, and sanitary water heating or process heating (cooling) using geothermal energy from a hydrothermal reservoir. The model can calculate geothermal heating and cooling costs for residential developments, a multi-district city, or a point demand such as an industrial factory or commercial building. GEOCITY simulates the complete geothermal heating and cooling system, which consists of two principal parts: the reservoir and fluid transmission system and the distribution system. The reservoir and fluid transmission submodel calculates the life-cycle cost of thermal energy supplied to the distribution system by simulating the technical design and cash flows for the exploration, development, and operation of the reservoir and fluid transmission system. The distribution system submodel calculates the life-cycle cost of heat (chill) delivered by the distribution system to the end-users by simulating the technical design and cash flows for the construction and operation of the distribution system. Geothermal space heating is assumed to be provided by circulating hot water through radiators, convectors, fan-coil units, or other in-house heating systems. Geothermal process heating is provided by directly using the hot water or by circulating it through a process heat exchanger. Geothermal space or process cooling is simulated by circulating hot water through lithium bromide/water absorption chillers located at each building. Retrofit costs for both heating and cooling applications can be input by the user. The life-cycle cost of thermal energy from the reservoir and fluid transmission system to the distribution system and the life-cycle cost of heat (chill) to the end-users are calculated using discounted cash flow analysis.

Huber, H.D.; Fassbender, L.L.; Bloomster, C.H.

1982-09-01T23:59:59.000Z

334

Phase Behavior and Emulsion Stability of the Aot/Decane/ Water/NaCl System at Very Low Volume Fractions of Oil  

E-Print Network [OSTI]

The stability of a ternary system composed of decane/water/Aerosol-OT and salt is revisited. Phase diagrams and emulsions similar in composition to those previously studied by Hofman and Stein [Hofman, 1991] were made. Ac- cording to our results, and contrary to the common experience, these systems exhibit a maximum of stability very close to the balance zone.

Yithanllili Bastidas; Lisset Hernaandez; Issarly Rivas; Kareem Rahn-Chique; German Urbina-Villalba

2014-10-09T23:59:59.000Z

335

SCALE: A modular code system for performing Standardized Computer Analyses for Licensing Evaluation. Volume 1, Part 2: Control modules S1--H1; Revision 5  

SciTech Connect (OSTI)

SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automated the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.3 of the system.

NONE

1997-03-01T23:59:59.000Z

336

Human-reliability data bank for nuclear-power-plant operations. Volume 2. A data-bank concept and system description  

SciTech Connect (OSTI)

The US Nuclear Regulatory Commission (NRC) is conducting a research program to determine the need for a human-reliability data bank unique to the nuclear industry. This report, in describing a proposed data bank, focuses primarily on four requirements: human-performance data collection, treatment, structuring (storage), and retrieval. Four data-collection methods are proposed: three are extensions to existing systems (i.e., Licensee Event Reports (LER), Nuclear Plant Reliability Data System (NPRDS), and Plant Incident Reports (PIR)); the fourth is a new system called the Nuclear Safety Reporting System (NSRS). Data treatment involves evaluating raw field data and data from other sources (e.g., training simulator, expert judgment, and performance modeling), and preparing them for entry into the data bank. Data structuring involves storage of data by equipment characteristics and human actions at the system, component, and individual control/display levels. Data retrieval uses a set of matrices based on the data-structuring taxonomy.

Comer, M.K.; Kozinsky, E.J.; Eckel, J.S.; Miller, D.P.

1983-02-01T23:59:59.000Z

337

SCALE: A modular code system for performing Standardized Computer Analyses for Licensing Evaluation. Volume 2, Part 3: Functional modules F16--F17; Revision 5  

SciTech Connect (OSTI)

SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automated the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.3 of the system.

NONE

1997-03-01T23:59:59.000Z

338

Forecast Technical Document Volume Increment  

E-Print Network [OSTI]

Forecast Technical Document Volume Increment Forecasts A document describing how volume increment is handled in the 2011 Production Forecast. Tom Jenkins Robert Matthews Ewan Mackie Lesley Halsall #12;PF2011 ­ Volume increment forecasts Background A volume increment forecast is a fundamental output of the forecast

339

Performance of ECM controlled VAV fan powered terminal units  

E-Print Network [OSTI]

signal from low pass filter h Enthalpy HVAC Heating, Ventilation, & Air Conditioning IRMS RMS value of current (amps) ? ? m mass flow rate Piav Inlet air velocity differential pressure Pdown Downstream static pressure Punit... Static pressure inside terminal unit Pup Upstream static pressure Powerfan Power consumption of terminal unit fan PF Power Factor PSC Permanent Split Capacitor ? ? Q Change in heat input per unit time Qfan Amount of airflow through...

Cramlet, Andrew Charles

2009-05-15T23:59:59.000Z

340

VAV Reheat Versus Active Chilled Beams and DOAS  

E-Print Network [OSTI]

Andrey. Don’t Turn Active Beams Into Expensive Diffusers,added costs of the piping and beams for ACBs are simply too1. Simmonds, Peter. To Beam or not To Beam? , Engineered

Stein, Jeff; Taylor, Steven

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Optimization of VAV AHU Terminal Box Minimum Airflow  

E-Print Network [OSTI]

. Table 3-1 Detail of constructions CONSTRUCTI ON NAME U-VALUE (BTU/HR-SQFT-F) SURFACE ABSORPTANCE SURFACE ROUGHNESS INDEX Exterior Wall Construction 0.084 0.6 1 Roof Construction 0.046 0.6 1 Ceiling Construction 0.514 0.7 3 Interior... Wall Construction 0.402 0.7 3 Interior Floor Construction 0.941 0.7 3 UFCons (G.1.U2) 0.244 0.7 3 17 Table 3-2 Simulation input data of internal gain Item Input Data People 115 W/person 200 ft2/person Lighting 1.4 W/ft2 Electrical...

Wang, Wei

2011-10-21T23:59:59.000Z

342

SciTech Connect: Nuclear power reactor instrumentation systems...  

Office of Scientific and Technical Information (OSTI)

Nuclear power reactor instrumentation systems handbook. Volume 1 Citation Details In-Document Search Title: Nuclear power reactor instrumentation systems handbook. Volume 1 You...

343

Model documentation natural gas transmission and distribution model (NGTDM) of the national energy modeling system. Volume II: Model developer`s report  

SciTech Connect (OSTI)

To partially fulfill the requirements for {open_quotes}Model Acceptance{close_quotes} as stipulated in EIA Standard 91-01-01 (effective February 3, 1991), the Office of Integrated Analysis and Forecasting has conducted tests of the Natural Gas Transmission and Distribution Model (NGTDM) for the specific purpose of validating the forecasting model. This volume of the model documentation presents the results of {open_quotes}one-at-a-time{close_quotes} sensitivity tests conducted in support of this validation effort. The test results are presented in the following forms: (1) Tables of important model outputs for the years 2000 and 2010 are presented with respect to change in each input from the reference case; (2) Tables of percent changes from base case results for the years 2000 and 2010 are presented for important model outputs; (3) Tables of conditional sensitivities (percent change in output/percent change in input) for the years 2000 and 2010 are presented for important model outputs; (4) Finally, graphs presenting the percent change from base case results for each year of the forecast period are presented for selected key outputs. To conduct the sensitivity tests, two main assumptions are made in order to test the performance characteristics of the model itself and facilitate the understanding of the effects of the changes in the key input variables to the model on the selected key output variables: (1) responses to the amount demanded do not occur since there are no feedbacks of inputs from other NEMS models in the stand-alone NGTDM run. (2) All the export and import quantities from and to Canada and Mexico, and liquefied natural gas (LNG) imports and exports are held fixed (i.e., there are no changes in imports and exports between the reference case and the sensitivity cases) throughout the forecast period.

Not Available

1995-01-03T23:59:59.000Z

344

Innovative coke oven gas cleaning system for retrofit applications. Environmental Monitoring program. Volume 1 - sampling progrom report. Baseline Sampling Program report  

SciTech Connect (OSTI)

Bethlehem Steel Corporation (BSC), in conjunction with the Department of Energy (DOE) is conducting a Clean Coal Technology (CCT) project at its Sparrows Point, Maryland Coke Oven Plant. This innovative coke oven gas cleaning system combines several existing technologies into an integrated system for removing impurities from Coke Oven Gas (COG) to make it an acceptable fuel. DOE provided cost-sharing under a Cooperative Agreement with BSC. This Cooperative Agreement requires BSC to develop and conduct and Environmental Monitoring Plan for the Clean Coal Technology project and to report the status of the EMP on a quarterly basis. It also requires the preparation of a final report on the results of the Baseline Compliance and Supplemental Sampling Programs that are part of the EMP and which were conducted prior to the startup of the innovative coke oven gas cleaning system. This report is the Baseline Sampling Program report.

Stuart, L.M.

1994-05-27T23:59:59.000Z

345

Development and Application of a Procedure to Estimate Overall Building and Ventilation Parameters from Monitored Commercial Building Energy Use  

E-Print Network [OSTI]

for CV system, VAV system and building load. 59 5.3 Monthly EDE for CV system, VAV system and building load 61 5.4 Monthly MEIc and MEIh for CV system, VAV system and building load.... 61 XU FIGURE Page 5.5 Multistep regression results with monitored... for for the BUS building pre and post retrofit 71 5.9 Monthly MEIc and MEIh for the BUS building pre and post retrofit 71 . 5.10 Monthly outdoor dry-bulb temperature and relative humidity conditions under which the HVAC systems were analyzed for the CSB building...

Deng, Song

346

TRADE nontechnical training programs inventory. Volume I  

SciTech Connect (OSTI)

In a continuing effort to facilitate communications and resource exchange among the DOE contractors, the TRADE (Training Resources and Data Exchange) Committee has compiled this volume. This inventory is one of four inventories, which taken together, total almost 1400 courses and reflect the range and focus of in-house training programs being offered throughout the DOE GOCO system by approximately 50 contractors.

Not Available

1984-10-01T23:59:59.000Z

347

October 23, 2012 11:49 World Scientific Review Volume -9in x 6in ywangsmartgrid Smart Grid, Automation, and SCADA Systems Security  

E-Print Network [OSTI]

systems), the electrical power industry, the coal industry, and the renewable resources (e.g., solar at the end of 2010, there are more than 9200 electric generating plants in USA, including coal, petroleum liquids, petroleum coke, natural gas, other gases, nuclear, hy- droelectric, renewables, hydroelectric

Wang, Yongge

348

[1] N. Abramson. The ALOHA system -another alternative for computer communications. In Proceedings of the Fall 1970 AFIPS Computer Conference, volume 37, pages 281-285, 1970.  

E-Print Network [OSTI]

. Montresor, and R. Segala. System support for partition-aware network applications. In 18th International hoc wireless networks. In Third International Workshop on Discrete Algorithms and Methods for Mobile fragmentation in mobile ad hoc networks. Journal of Communications and Networks., 2(3):182-187, Sept. 2000. ISSN

Briesemeister, Linda

349

Waste Isolation Pilot Plant Shaft Sealing System Compliance Submittal Design Report. Volume 1 and 2: Main report, appendices A, B, C, and D  

SciTech Connect (OSTI)

This report describes a shaft sealing system design for the Waste Isolation Pilot Plant (WIPP), a proposed nuclear waste repository in bedded salt. The system is designed to limit entry of water and release of contaminants through the four existing shafts after the WIPP is decommissioned. The design approach applies redundancy to functional elements and specifies multiple, common, low-permeability materials to reduce uncertainty in performance. The system comprises 13 elements that completely fill the shafts with engineered materials possessing high density and low permeability. Laboratory and field measurements of component properties and performance provide the basis for the design and related evaluations. Hydrologic, mechanical, thermal, and physical features of the system are evaluated in a series of calculations. These evaluations indicate that the design guidance is addressed by effectively limiting transport of fluids within the shafts, thereby limiting transport of hazardous material to regulatory boundaries. Additionally, the use or adaptation of existing technologies for placement of the seal components combined with the use of available, common materials assure that the design can be constructed.

NONE

1996-08-01T23:59:59.000Z

350

Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume II. Text  

SciTech Connect (OSTI)

The conceptual design, parametric analysis, cost and performance analysis, and a commercial assessment of a 100-MWe high-temperature line-focus central power system are presented. Parametric analyses and conceptual design of the heliostat subsystem, receiver subsystem, heat transport subsystem, energy storage subsystem, electrical power generating subsystem, and master control subsystem are included. A market analysis and development plan are given. (WHK)

Slemmons, A J

1980-04-01T23:59:59.000Z

351

International Journal of Computer Information Systems and Industrial Management Applications ISSN 2150-7988 Volume 3 (2011) pp. 248-255  

E-Print Network [OSTI]

International Journal of Computer Information Systems and Industrial Management Applications ISSN formulated into a ligand-protein binding energy optimization problem. Dozens of programs have been developed with lower binding energy and to minimize the computational time. Recently, there is significant progress

Hu, Jianjun

352

Fluor Hanford Integrated Safety Management System Phase 1 Verification 04/12/2000 Thru 04/28/2000 Volume 1 and 2  

E-Print Network [OSTI]

The U.S. Department of Energy (DOE) commits to accomplishing its mission safely. To ensure this objective is met, DOE issued DOE P 450.4, Safety Management System Policy, and incorporated safety management into the DOE Acquisition Regulations ([DEAR] 48 CFR 970.5204-2 and 90.5204-78).

Parsons, J E

2000-01-01T23:59:59.000Z

353

Assessment of effectiveness of geologic isolation systems. Geologic-simulation model for a hypothetical site in the Columbia Plateau. Volume 2: results  

SciTech Connect (OSTI)

This report contains the input data and computer results for the Geologic Simulation Model. This model is described in detail in the following report: Petrie, G.M., et. al. 1981. Geologic Simulation Model for a Hypothetical Site in the Columbia Plateau, Pacific Northwest Laboratory, Richland, Washington. The Geologic Simulation Model is a quasi-deterministic process-response model which simulates, for a million years into the future, the development of the geologic and hydrologic systems of the ground-water basin containing the Pasco Basin. Effects of natural processes on the ground-water hydrologic system are modeled principally by rate equations. The combined effects and synergistic interactions of different processes are approximated by linear superposition of their effects during discrete time intervals in a stepwise-integration approach.

Foley, M.G.; Petrie, G.M.; Baldwin, A.J.; Craig, R.G.

1982-06-01T23:59:59.000Z

354

Vol 1, Integrated Safety Management System Guide (Volume 1), Chapter IV - Approved on March 28, 2000 and Added to the Guide  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Department of Energy (DOE) Integrated Safety Management System (ISMS) Guide is approved for use by the Office of Environment, Safety and Health (EH) and is available for use by all DOE components and their contractors. This Guide is a consensus document coordinated by EH and prepared under the direction of the DOE Safety Management Implementation Team (SMIT). Canceled by DOE G 450.4-1B.

2000-03-28T23:59:59.000Z

355

Development and application of optimal design capability for coal gasification systems - Task 1 (Volume 1, 2 and 3). Topical report, July 1995  

SciTech Connect (OSTI)

Selective catalytic reduction (SCR) is a process for the post-combustion removal of NO{sub x} from the flue gas of fossil-fuel-fired power plants. SCR is capable of NO{sub x} reduction efficiencies of up to 80 or 90 percent. SCR technology has been applied for treatment of flue gases from a variety of emission sources, including natural gas- and oil-fired gas turbines, process steam boilers in refineries, and coal-fired power plants. SCR applications to coal-fired power plants have occurred in Japan and Germany. Full-scale SCR systems have not been applied to coal-fired power plants in the U.S., although there have been small-scale demonstration projects. SCR has become increasingly widely applied in the U.S. to natural-gas fired gas turbine combined cycle systems. In the remainder of this section, we review the applicability of SCR, as well as the need for post-combustion NO{sub x} control, for several power generation systems.

NONE

1995-09-01T23:59:59.000Z

356

Publications Edited Volume  

E-Print Network [OSTI]

of Robots with Passive Environments: Application to Force Feedback Control Ed Colgate and Neville Hogan, J. Edward Colgate Industrial Robot, 26 (5), 1999, pp 335-341 Toward Robot-Assisted VascularPublications Edited Volume Advances in Robotics, Mechatronics, and Haptic Interfaces 1993 Edited

MacIver, Malcolm A.

357

Hamiltonian and Volume Operators  

E-Print Network [OSTI]

2+1 gravity coupled to a massless scalar field has an initial singularity when the spatial slices are compact. The quantized model is used here to investigate several issues of quantum gravity. The spectrum of the volume operator is studied at the initial singularity. The energy spectrum is obtained. Dynamics of the universe is also investigated.

M. Pierri

2002-01-04T23:59:59.000Z

358

Suspended microchannel resonators for ultralow volume universal detection  

E-Print Network [OSTI]

Universal detectors that maintain high sensitivity as the detection volume is reduced to the sub-nanoliter scale can enhance the utility of miniaturized total analysis systems ([mu]-TAS). Here the unique scaling properties ...

Son, Sungmin

2008-01-01T23:59:59.000Z

359

Electronic Communications of the EASST Volume 13 (2008)  

E-Print Network [OSTI]

Electronic Communications of the EASST Volume 13 (2008) Proceedings of the Second International with Interactivity for Analysing (Automotive) Communication Sequences Michael Sedlmair1 BMW Group Research describe interactions in distributed systems. Our approach proposes the enrichment of large scaled MSCs

360

Topology-controlled volume rendering  

E-Print Network [OSTI]

type. Even when volume render- ing is applied to nonmedicalin graphics hardware. We render tubes between saddles and

Weber, Gunther H; Dillard, Scott E; Carr, Hamish; Pascucci, Valerio; Hamann, Bernd

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Statistical Ensembles with Volume Fluctuations  

E-Print Network [OSTI]

The volume fluctuations in statistical mechanics are discussed. First, the volume fluctuations in ensembles with a fixed external pressure, the so called pressure ensembles, are considered. Second, a generalization of the pressure ensembles is suggested. Namely, the statistical ensembles with the volume fluctuating according to externally given distributions are considered. Several examples and possible applications in statistical models of hadron production are discussed.

Mark I. Gorenstein

2008-06-17T23:59:59.000Z

362

EngineRoom: A Comparative Development Environment For Volume Rendering Engines  

E-Print Network [OSTI]

- 1 - EngineRoom: A Comparative Development Environment For Volume Rendering Engines Michael A for comparative volume rendering, fast prototyping of system components, and teaching. Engine Room's manager-driven architecture is able to: (i) dynamically dock or link multiple third- party volume rendering engines

Mueller, Klaus

363

Long-term embrittlement of cast duplex stainless steels in LWR systems. Semiannual report, April--September 1992: Volume 7, No. 2  

SciTech Connect (OSTI)

This progress report summarizes work performed by Argonne National Laboratory on longterm thermal embrittlement of cast duplex stainless steels in LWR systems during the six months from April--September 1992. A procedure and correlations are presented for predicting Charpy-impact energy, tensile flow stress, fracture toughness J-R curve, tearing modulus, and J{sub IC} of aged cast stainless steels from known material information. The ``saturation`` impact strength and fracture toughness of a specific cast stainless steel, i.e., the minimum value that would be achieved for the material after long-term service, is estimated from the chemical composition of the steel. Mechanical properties as a function of time and temperature of reactor service are estimated from impact energy and flow stress of the unaged material and the kinetics of embrittlement, which are also determined from chemical composition. The J{sub IC} values are determined from the estimated J-R curve and flow stress. Examples of estimating mechanical properties of cast stainless steel components during reactor service are presented. A common ``lower-bound`` J-R curve for cast stainless steels of unknown chemical composition is also defined for a given grade of steel, ferrite content, and temperature.

Chopra, O.K. [Argonne National Lab., IL (United States)

1993-07-01T23:59:59.000Z

364

Information architecture. Volume 3: Guidance  

SciTech Connect (OSTI)

The purpose of this document, as presented in Volume 1, The Foundations, is to assist the Department of Energy (DOE) in developing and promulgating information architecture guidance. This guidance is aimed at increasing the development of information architecture as a Departmentwide management best practice. This document describes departmental information architecture principles and minimum design characteristics for systems and infrastructures within the DOE Information Architecture Conceptual Model, and establishes a Departmentwide standards-based architecture program. The publication of this document fulfills the commitment to address guiding principles, promote standard architectural practices, and provide technical guidance. This document guides the transition from the baseline or defacto Departmental architecture through approved information management program plans and budgets to the future vision architecture. This document also represents another major step toward establishing a well-organized, logical foundation for the DOE information architecture.

NONE

1997-04-01T23:59:59.000Z

365

Hanford spent nuclear fuel project recommended path forward, volume III: Alternatives and path forward evaluation supporting documentation  

SciTech Connect (OSTI)

Volume I of the Hanford Spent Nuclear Fuel Project - Recommended Path Forward constitutes an aggressive series of projects to construct and operate systems and facilities to safely retrieve, package, transport, process, and store K Basins fuel and sludge. Volume II provided a comparative evaluation of four Alternatives for the Path Forward and an evaluation for the Recommended Path Forward. Although Volume II contained extensive appendices, six supporting documents have been compiled in Volume III to provide additional background for Volume II.

Fulton, J.C.

1994-10-01T23:59:59.000Z

366

High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation  

E-Print Network [OSTI]

High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation Keynote Automation 2 AcknowledgementsAcknowledgements · Many of the ideas in this presentation were initially jointly developed with Doug Hoffman,as we developed a course on test automation architecture, and in the Los Altos

367

Industrial cogeneration optimization program. Volume II. Appendix A. Conceptual designs and preliminary equipment specifications. Appendix B. Characterization of cogeneration systems (near-term technology). Appendix C. Optimized cogeneration systems  

SciTech Connect (OSTI)

This appendix to a report which evaluates the technical, economic, and institutional aspects of industrial cogeneration for conserving energy in the food, chemical, textile, paper, and petroleum industries contains data, descriptions, and diagrams on conceptual designs and preliminary equipment specifications for cogeneration facilities; characterization of cogeneration systems in terms of fuel utilization, performance, air pollution control, thermal energy storage systems, and capital equipment costs; and optimized cogeneration systems for specific industrial plants. (LCL)

Not Available

1980-01-01T23:59:59.000Z

368

Volume strain within the Geysers geothermal field  

SciTech Connect (OSTI)

During the 1970s and 1980s. The Geysers geothermal region was rapidly developed as a site of geothermal power production. The likelihood that this could cause significant strain within the reservoir, with corresponding surface displacements, led to a series of deformation monitoring surveys. In 1973, 1975, 1977, and 1980, The Geysers region was surveyed using first-order, class I, spirit leveling. In 1994, 1995, and 1996, many of the leveling control monuments were resurveyed using high-precision Global Positioning System receivers. The two survey methods are reconciled using the GEOID96 geoid model. The displacements are inverted to determine volume strain within the reservoir. For the period 1980-1994, peak volume strains in excess of 5x10{sup -4} are imaged. There is an excellent correlation between the observed changes in reservoir steam pressures and the imaged volume strain. If reservoir pressure changes are inducing volume strain, then the reservoir quasi-static bulk modulus K must be <4.6x10{sup 9} Pa. However, seismic velocities indicate a much stiffer reservoir with K=3.4x10{sup 10} Pa. This apparent discrepancy is shown to be consistent with predicted frequency dependence in K for fractured and water-saturated rock. Inversion of surface deformation data therefore appears to be a powerful method for imaging pressure change within the body of the reservoir. Correlation between induced seismicity at The Geysers and volume strain is observed. However, earthquake distribution does not appear to have a simple relationship with volume strain rate. (c) 1999 American Geophysical Union.

Mossop, Antony [Department of Geophysics, Stanford University, Stanford, California (United States)] [Department of Geophysics, Stanford University, Stanford, California (United States); Segall, Paul [Department of Geophysics, Stanford University, Stanford, California (United States)] [Department of Geophysics, Stanford University, Stanford, California (United States)

1999-12-10T23:59:59.000Z

369

E-Print Network 3.0 - arterial pressure-volume relationship Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

pressure-volume relationship Page: << < 1 2 3 4 5 > >> 1 In the simplest functional terms, closed circulatory systems such as those of vertebrates, crustaceans and cephalopod...

370

Volume Rendering in a Virtual Environment Jrgen Schulze-Dbold, Uwe Wssner, Steffen P. Walz, Ulrich Lang  

E-Print Network [OSTI]

Volume Rendering in a Virtual Environment Jürgen Schulze-Döbold, Uwe Wössner, Steffen P. Walz,woessner,walz,lang}@hlrs.de Abstract. This paper describes a flexible rendering system for scalar volume data which has been integrated into the visualization system COVISE. It allows direct volume rendering based on texture mapping hardware on both

Schulze, Jürgen P.

371

Hydraulic conductivity testing of geosynthetic clay liners (GCLs) using the constant volume method  

SciTech Connect (OSTI)

Hydraulic conductivity tests were conducted using open and constant-volume permeation systems on specimens from a geosynthetic clay liner (GCL). Two constant volume (CV) systems were employed: the falling-head constant-volume (FHCV) system and the constant-head constant-volume (CHCV) system. A conventional burette system using pressurized air was employed for the open system (OS) tests. The test results show that hydraulic conductivity tests can be conducted 30 or more times faster with the FHCV and CHCV systems than with an open system. Typically the permeation portion of the FHCV and CHCV tests can be conducted in one-half day. Slightly lower hydraulic conductivities are measured with the CV systems due to the slightly higher effective stress applied during testing with these systems. The CHCV system has several advantages over the FHCV system, including minimizing initial transient behavior, constant applied effective stress during testing, and simpler calculations.

Wang, X.; Benson, C.H.

1999-12-01T23:59:59.000Z

372

Comparative Study of Availability on Energy/Environment Commissioning Using Existing HVAC Simulation Programs for a Model Building  

E-Print Network [OSTI]

limit of VAV air flow rate: 50% of minimum ? Heat Source System: Thermal storage system using AHP(Air-soure HeatPumps) ? Performance characteristics of fan, pump, heat pump are defined as manufacturer's ? Internal heat gain schedules are set...

Niwa, H.; Nakahara, N.; Okumiya, M.; Suganaga, M.; Tanaka, H.; Pan, S.; Watanabe, T.; Zheng, M.

2004-01-01T23:59:59.000Z

373

Lokaratna, Volume 4  

E-Print Network [OSTI]

Muthukumarswamy and his colleagues of NFSC, Chennai to support this volume to be published in their web site for a global readership. On behalf of Folklore Foundation, Odisha Bhubaneswar , I wish a Happy and prosperous new Year 2012... not create the tiger to prey upon man, but to hunt, to provide food for him […]. Magicians are, however, believed to have acquired the power to take away life at pleasure, without reference to the will of the gods, by dark and impious arts which are purely...

Mishra, Mahendra Kumar

2011-01-01T23:59:59.000Z

374

Lokaratna, Volume 3  

E-Print Network [OSTI]

Support Center, and Chennai for his support to get this volume published in NFSC web site for the wider readership. I am also thankful to Prof. Mark Turin of Cambridge University who has been kinds enough to link the web journal of Folklore... of Nature such as cloud, sky, Tam?la trees, night and Yamun? river have been illustrated. Moreover, all these aspects are blackish by nature and very similar to the dark-bodied Krishna. It may be undoubtedly stated that the poet has consciously used...

Mishra, Mahendra Kumar

375

FY 2005 Volume 5  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA5 &of Energy memoCityTheDepartmentKey9Statistical6 Volume 5

376

FY 2005 Volume 6  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA5 &of Energy memoCityTheDepartmentKey9Statistical6 Volume 57

377

FY 2005 Volume 7  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA5 &of Energy memoCityTheDepartmentKey9Statistical6 Volume

378

Texas Rice, Volume VI, Number 7  

E-Print Network [OSTI]

Texas A&M University System Agricultural Research and Extension Center Beaumont, Texas September 2006 Volume VI Number 7 Texas A Tribute to Henry M. “Hank” Beachell Henry Monroe Beachell, co- recipient of the 1996 World Food Prize... was the need for additional research, particularly addressing the development of rice varieties that compete more effectively with weed species, and the development of improved weed and fertilizer management options. The U.S. organic market is projected...

379

Void volumes in subcooled boiling systems  

E-Print Network [OSTI]

Introduction: Knowledge of the pressure drop in a channel and the resulting flow redistribution is essential in predicting the performance of a nuclear reactor. The pressure drop in a channel which is experiencing boiling ...

Griffith, P.

1958-01-01T23:59:59.000Z

380

Study of the 1991 unaccounted-for gas volume at the Southern California Gas Company. Final report, January 1991-December 1992. Volume 1. Project summary  

SciTech Connect (OSTI)

A study of unaccounted-for gas (UAF), performed by the Southern California Gas Company (SoCalGas) to determine the UAF gas volume in the SoCalGas system, to identify the factors contributing to UAF, and to estimate the gas volume associated with each factor, is described. It was found that measurement-related effects contributed more than 80% of SoCalGas' 1991 UAF volume. Less than 3% is associated with adjustments to SoCalGas' accounting system, and approximately 6% is associated with losses due to theft. Testing showed that the leakage element contributed only 8% of the UAF volume.

Meshkati, S.; Groot, J.; Law, E.; Ozenne, D.

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Study of the 1991 unaccounted-for gas volume at the Southern California Gas Company. Final report, January 1991-December 1992. Volume 4. Leakage  

SciTech Connect (OSTI)

As part of a study of unaccounted-for gas (UAF) at the Southern California Gas Company (SoCalGas), volume IV of the six-volume set reports on the UAF leakage volumes associated with the transmission and distribution piping systems, each analyzed separately. Unplanned gas releases in SoCalGas distribution and transmission operations contributed approximately 871,900 thousand cubic feet to the 1991 UAF volume. The study indicated that SoCalGas' current leak detection program has been successful in reducing the number of leaks throughout the distribution system, with the sensitive detection equipment finding leaks earlier in their development and reducing the average leakage rate.

Meshkati, S.; Groot, J.; Bruni, J.; Crebs, S.; Law, E.

1993-04-01T23:59:59.000Z

382

Model for the free-volume distributions of equilibrium fluids  

E-Print Network [OSTI]

We introduce and test via molecular simulation a simple model for predicting the manner in which interparticle interactions and thermodynamic conditions impact the single-particle free-volume distributions of equilibrium fluids. The model suggests a scaling relationship for the density-dependent behavior of the hard-sphere system. It also predicts how the second virial coefficients of fluids with short-range attractions affect their free-volume distributions.

William P. Krekelberg; Venkat Ganesan; Thomas M. Truskett

2006-06-01T23:59:59.000Z

383

Using Photogrammetry to Estimate Tank Waste Volumes from Video  

SciTech Connect (OSTI)

Washington River Protection Solutions (WRPS) contracted with HiLine Engineering & Fabrication, Inc. to assess the accuracy of photogrammetry tools as compared to video Camera/CAD Modeling System (CCMS) estimates. This test report documents the results of using photogrammetry to estimate the volume of waste in tank 241-C-I04 from post-retrieval videos and results using photogrammetry to estimate the volume of waste piles in the CCMS test video.

Field, Jim G. [Washington River Protection Solutions, LLC, Richland, WA (United States)

2013-03-27T23:59:59.000Z

384

Site Environmental Report for 2012, Volumes 1& 2  

SciTech Connect (OSTI)

This report provides a comprehensive summary of the environmental program activities at LBNL for the calendar year 2012. Volume I is organized into an executive summary followed by six chapters that include an overview of LBNL, a discussion of its Environmental Management System (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities.

Pauer, Ron; Baskin, David; Bauters, Tim; Borglin, Ned; Fox, Robert; Horst, Blair; Jelinski, John; Lackner, Ginny; Philliber, Jeff; Thorson, Patrick; Wahl, Linnea; Wehle, Petra; Xu, Suying; None

2013-09-30T23:59:59.000Z

385

Electric utility engineer`s FGD manual -- Volume 2: Major mechanical equipment; FGD proposal evaluations; Use of FGDPRISM in FGD system modification, proposal, evaluation, and design; FGD system case study. Final report  

SciTech Connect (OSTI)

Part 2 of this manual provides the electric utility engineer with detailed technical information on some of the major mechanical equipment used in the FGD system. The objectives of Part 2 are the following: to provide the electric utility engineer with information on equipment that may be unfamiliar to him, including ball mills, vacuum filters, and mist eliminators; and to identify the unique technique considerations imposed by an FGD system on more familiar electric utility equipment such as fans, gas dampers, piping, valves, and pumps. Part 3 provides an overview of the recommended procedures for evaluating proposals received from FGD system vendors. The objectives are to provide procedures for evaluating the technical aspects of proposals, and to provide procedures for determining the total costs of proposals considering both initial capital costs and annual operating and maintenance costs. The primary objective of Part 4 of this manual is to provide the utility engineer who has a special interest in the capabilities of FGDPRISM [Flue Gas Desulfurization PRocess Integration and Simulation Model] with more detailed discussions of its uses, requirements, and limitations. Part 5 is a case study in using this manual in the preparation of a purchase specification and in the evaluation of proposals received from vendors. The objectives are to demonstrate how the information contained in Parts 1 and 2 can be used to improve the technical content of an FGD system purchase specification; to demonstrate how the techniques presented in Part 3 can be used to evaluate proposals received in response to the purchase specification; and to illustrate how the FGDPRISM computer program can be used to establish design parameters for the specification and evaluate vendor designs.

NONE

1996-03-04T23:59:59.000Z

386

Integrated Safety Management System Guide (Volume 1) for use with Safety Management System Policies (DOE P 450.4, DOE P 450.5, and DOE P 450.6); The Functions, Responsibilities, and Authorities Manual; and DOE Acquisition Regulation  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Department of Energy (DOE) Integrated Safety Management System (ISMS) Guide is approved for use by the Office of Environment, Safety and Health (EH) and the National Nuclear Security Administration (NNSA). This Guide is available for use by all DOE components and their contractors. This Guide is a consensus document coordinated by EH and prepared under the direction of the DOE Safety Management Implementation Team (SMIT). Replaces DOE G 450.4-1A. Canceled by DOE G 450.4-1C.

2001-03-01T23:59:59.000Z

387

Integrated Safety Management System Guide (Volume 1) for use with Safety Management System Policies (DOE P 450.4, DOE P 450.5, and DOE P 450.6); The Functions, Responsibilities, and Authorities Manual; and DOE Acquisition Regulation  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Department of Energy (DOE) Integrated Safety Management System (ISMS) Guide is approved for use by the Office of Environment, Safety and Health (EH) and the National Nuclear Security Administration (NNSA). This Guide is available for use by all DOE components and their contractors. This Guide is a consensus document coordinated by EH and prepared under the direction of the DOE Safety Management Implementation Team (SMIT). Canceled by DOE G 450.4-1C.

2001-03-01T23:59:59.000Z

388

1996 Site environmental report. Volume II  

SciTech Connect (OSTI)

Ernest Orlando Lawrence Berkeley National Laboratory presents Volume II, data appendix as a reference document to supplement the 1996 Site Environmental Report. Volume II contains the raw environmental monitoring and sampling data used to generate many of the summary results included in the main report for both routine and nonroutine activities. This appendix includes a legend that cross-references the enclosed data tables with summary tables in the main report. The legend also provides a listing of more detailed descriptions for the station location codes used in the appendices` tables. Data presented in the tables are given in Systeme International (SI) units. The glossary found in the main report contains a listing of the SI units.

NONE

1997-09-01T23:59:59.000Z

389

Proceedings of the 1995 U.S. DOE hydrogen program review, Volume 1  

SciTech Connect (OSTI)

This document containes reports from the proceedings of the 1995 U.S. DOE hydrogen program review. Reports are organized under the topics of systems analysis, utilization, storage, and production. This volume, Volume I, contains the reports concerned with systems analysis and utilization. Individual reports were processed separately for the DOE data bases.

NONE

1995-09-01T23:59:59.000Z

390

Test Access Mechanism Optimization, Test Scheduling, and Tester Data Volume  

E-Print Network [OSTI]

Test Access Mechanism Optimization, Test Scheduling, and Tester Data Volume Reduction for System Marinissen, Senior Member, IEEE Abstract--We describe an integrated framework for system-on-chip (SOC) test automation. Our framework is based on a new test access mechanism (TAM) architecture consisting of flexible

Chakrabarty, Krishnendu

391

Microfluidic Systems Integrated Microfluidic Systems**  

E-Print Network [OSTI]

Microfluidic Systems Integrated Microfluidic Systems** Rustem F. Ismagilov* Keywords: analytical methods · enzymes · microfluidics · microreactors · protein structures Microfluidic systems use networks of channels thinner than a human hair to manipulate nanoliter volumes of re- agents. The goal of microfluidics

Ismagilov, Rustem F.

392

The second iteration of the Systems Prioritization Method: A systems prioritization and decision-aiding tool for the Waste Isolation Pilot Plant: Volume 1, Synopsis of method and results  

SciTech Connect (OSTI)

In March 1994, the US Department of Energy Carlsbad Area Office (DOE/CAO) embarked on an effort to design and implement a performance- based decision-aiding tool to provide an analytical basis for planning, prioritizing, and selecting programmatic options for the Waste Isolation Pilot Plant (WIPP). This tool, called Systems Prioritization Method (SPM) defines the most viable combinations of scientific investigations, engineered alternatives (EAs), and waste acceptance criteria (WAC) for supporting the final WIPP compliance application. The scope of SPM is restricted to selected portions of applicable Environmental Protection Agency (EPA) long-term performance regulations. SPM calculates the probabilities of certain sets of activities demonstrating compliance with various regulations. SPM provides results in the form of a decision matrix to identify cost-effective programmatic paths with a high probability of successfully demonstrating compliance.

Prindle, N.H.; Mendenhall, F.T.; Boak, D.M. [and others

1996-05-01T23:59:59.000Z

393

A phase-space model for Pleistocene ice volume  

E-Print Network [OSTI]

We present a phase-space model that simulates Pleistocene ice volume changes based on Earth's orbital parameters. Terminations in the model are triggered by a combination of ice volume and orbital forcing and agree well with age estimates for Late Pleistocene terminations. The average phase at which model terminations begin is approximately 90 +/- 90 degrees before the maxima in all three orbital cycles. The large variability in phase is likely caused by interactions between the three cycles and ice volume. Unlike previous ice volume models, this model produces an orbitally driven increase in 100-kyr power during the mid-Pleistocene transition without any change in model parameters. This supports the hypothesis that Pleistocene variations in the 100-kyr power of glacial cycles could be caused, at least in part, by changes in Earth's orbital parameters, such as amplitude modulation of the 100-kyr eccentricity cycle, rather than changes within the climate system.

Imbrie, John Z; Lisiecki, Lorraine E

2011-01-01T23:59:59.000Z

394

Site Environmental Report for 2008, Volume II  

E-Print Network [OSTI]

Volume I: Collection Stack Air Ambient Air Rainwater Creekscollection activities Volume II section Stormwater Ambient Air; RainwaterRainwater Radiological Activity Analyte Gross alpha Location* ENV-44 Collection

Lackner, Regina

2009-01-01T23:59:59.000Z

395

RELAP5/MOD3 code manual. Volume 4, Models and correlations  

SciTech Connect (OSTI)

The RELAP5 code has been developed for best-estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents and operational transients such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I presents modeling theory and associated numerical schemes; Volume II details instructions for code application and input data preparation; Volume III presents the results of developmental assessment cases that demonstrate and verify the models used in the code; Volume IV discusses in detail RELAP5 models and correlations; Volume V presents guidelines that have evolved over the past several years through the use of the RELAP5 code; Volume VI discusses the numerical scheme used in RELAP5; and Volume VII presents a collection of independent assessment calculations.

NONE

1995-08-01T23:59:59.000Z

396

Study of the 1991 unaccounted-for gas volume at the Southern California Gas Company. Final report, January 1991-December 1992. Volume 3. Measurement  

SciTech Connect (OSTI)

As part of a study of unaccounted-for gas (UAF) at the Southern California Gas Company, volume III of the six-volume set contains the results of measurement factors analysis, including both estimates of UAF due to fixed-factor assumptions and meter accuracy. Accurate measurement of gas volume is a function of the meter and the factors used to adjust the meter read. If the meter registers slow or fast, the actual gas volume passing through the meter will not be measured true. The estimated UAF volume from all measurement elements resulted in an overall net under-measurement of the 1991 gas volume in the SoCalGas system of 8,048,800 thousand cubic feet. Appendices include tabular numerical and graphic information on measurement parameters and other supplemental data.

Meshkati, S.; Groot, J.; Aquin, D.; Beloat, B.; Epps, B.

1993-04-01T23:59:59.000Z

397

Utilities and offsites design baseline. Outside Battery Limits Facility 6000 tpd SRC-I Demonstration Plant. Volume 1  

SciTech Connect (OSTI)

As part of the overall Solvent Refined Coal (SRC-1) project baseline being prepared by International Coal Refining Company (ICRC), the RUST Engineering Company is providing necessary input for the Outside Battery Limits (OSBL) Facilities. The project baseline is comprised of: design baseline - technical definition of work; schedule baseline - detailed and management level 1 schedules; and cost baseline - estimates and cost/manpower plan. The design baseline (technical definition) for the OSBL Facilities has been completed and is presented in Volumes I, II, III, IV, V and VI. The OSBL technical definition is based on, and compatible with, the ICRC defined statement of work, design basis memorandum, master project procedures, process and mechanical design criteria, and baseline guidance documents. The design basis memorandum is included in Paragraph 1.3 of Volume I. The baseline design data is presented in 6 volumes. Volume I contains the introduction section and utility systems data through steam and feedwater. Volume II continues with utility systems data through fuel system, and contains the interconnecting systems and utility system integration information. Volume III contains the offsites data through water and waste treatment. Volume IV continues with offsites data, including site development and buildings, and contains raw materials and product handling and storage information. Volume V contains wastewater treatment and solid wastes landfill systems developed by Catalytic, Inc. to supplement the information contained in Volume III. Volume VI contains proprietary information of Resources Conservation Company related to the evaporator/crystallizer system of the wastewater treatment area.

None

1984-05-25T23:59:59.000Z

398

REORIENTAO Ensino Mdio -Volume I  

E-Print Network [OSTI]

REORIENTAÇĂO CURRICULAR PORTUGUĘS Ensino Médio - Volume I Materiais Didáticos #12;#12;GOVERNO DO SUBSECRETARIA ADJUNTA DE PLANEJAMENTO PEDAGÓGICO Alba Rodrigues Cruz #12;#12;GOVERNO DO ESTADO DO RIO DE JANEIRO

Liu, I-Shih

399

Texas Rice, Volume VII, Number 7  

E-Print Network [OSTI]

Texas A&M University System Agricultural Research and Extension Center Beaumont, Texas September 2007 Volume VII Number 7 Texas Rice Nobel Peace Prize Recipient Dr. Norman Borlaug continued on page 4 September of 2003 was a time etched... Tabien, and Dr. Lee Tarpley. Four years ago this month, the Texas A&M Research and Exten- sion Center at Beaumont was hon- ored to welcome one of the most influential people in agriculture. Nobel Peace Prize recipient, Dr. Norman Borlaug, has a long...

400

High volume production of nanostructured materials  

DOE Patents [OSTI]

A system and method for high volume production of nanoparticles, nanotubes, and items incorporating nanoparticles and nanotubes. Microwave, radio frequency, or infrared energy vaporizes a metal catalyst which, as it condenses, is contacted by carbon or other elements such as silicon, germanium, or boron to form agglomerates. The agglomerates may be annealed to accelerate the production of nanotubes. Magnetic or electric fields may be used to align the nanotubes during their production. The nanotubes may be separated from the production byproducts in aligned or non-aligned configurations. The agglomerates may be formed directly into tools, optionally in compositions that incorporate other materials such as abrasives, binders, carbon-carbon composites, and cermets.

Ripley, Edward B. (Knoxville, TN); Morrell, Jonathan S. (Knoxville, TN); Seals, Roland D. (Oak Ridge, TN); Ludtka, Gerard M. (Oak Ridge, TN)

2009-10-13T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Site Environmental Report for 2007 Volume I  

SciTech Connect (OSTI)

The Site Environmental Report is an integrated report on Berkeley Lab's environmental programs to satisfy the requirements of DOE Order 231.1A, Environment, Safety, and Health Reporting. It summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2007. Volume I is organized into an executive summary followed by six chapters that contain an overview of the Laboratory, a discussion of the Laboratory's environmental management system, the status of environmental programs, and summarized results from surveillance and monitoring activities.

Lackner, Regina E.; Baskin, David; Fox, Robert; Jelinski, John; Pauer, Ron; Thorson, Patrick; Wahl, Linnea

2008-09-15T23:59:59.000Z

402

Large volume flow-through scintillating detector  

DOE Patents [OSTI]

A large volume flow through radiation detector for use in large air flow situations such as incinerator stacks or building air systems comprises a plurality of flat plates made of a scintillating material arranged parallel to the air flow. Each scintillating plate has a light guide attached which transfers light generated inside the scintillating plate to an associated photomultiplier tube. The output of the photomultiplier tubes are connected to electronics which can record any radiation and provide an alarm if appropriate for the application.

Gritzo, Russ E. (Los Alamos, NM); Fowler, Malcolm M. (Los Alamos, NM)

1995-01-01T23:59:59.000Z

403

Photogrammetry and Laser Imagery Tests for Tank Waste Volume Estimates: Summary Report  

SciTech Connect (OSTI)

Feasibility tests were conducted using photogrammetry and laser technologies to estimate the volume of waste in a tank. These technologies were compared with video Camera/CAD Modeling System (CCMS) estimates; the current method used for post-retrieval waste volume estimates. This report summarizes test results and presents recommendations for further development and deployment of technologies to provide more accurate and faster waste volume estimates in support of tank retrieval and closure.

Field, Jim G. [Washington River Protection Solutions, LLC, Richland, WA (United States)

2013-03-27T23:59:59.000Z

404

FY 2012 Volume 3  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power SystemsResourcesFLASH2011-11-OPAMFY 2007 Total System Life Cycle Cost,62 CEnergy AndS6578

405

Film Collection Volume One  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series toESnet4:EpitaxialtransatlanticUnified ForcesFile Systems File SystemsOne

406

Forecast Technical Document Growing Stock Volume  

E-Print Network [OSTI]

Forecast Technical Document Growing Stock Volume Forecasts A document describing how growing stock (`standing') volume is handled in the 2011 Production Forecast. Tom Jenkins Robert Matthews Ewan Mackie Lesley Halsall #12;PF2011 ­ Growing stock volume forecasts Background A forecast of standing volume (or

407

Advanced Thermionic Technology Program: summary report. Volume 1. Final report  

SciTech Connect (OSTI)

This report summarizes the progress made by the Advanced Thermionic Technology Program during the past several years. This program, sponsored by the US Department of Energy, has had as its goal adapting thermionic devices to generate electricity in a terrestrial (i.e., combustion) environment. The technology has previously been developed for astronautical applications. The report is organized in four volumes, each focused as much as possible on the needs of a particular audience. Volume 1 contains Part A, the Executive Summary. This Executive Summary describes the accomplishments of the Program in brief, but assumes the reader's familiarity with the thermionic process and the technical issues associated with the Program. For this reason, Volume 1 also contains Part B, a minimally technical overview of the Advanced Thermionic Technology Program. Volume 2 (Part C) concentrates on the progress made in developing and fabricating the ''current generation'' of chemical vapor deposited hot shell thermionic converters and is addressed to those primarily concerned with today's capabilities in terrestrial thermionic technology. Volume 3 (Part D) contains the results of systems studies of primary interest to those involved in identifying and evaluating applications for thermionics. Volume 4 (Part E) is a highly technical discussion of the attempts made by the program to push the state-of-the-art beyond the current generation of converters and is directed toward potential researchers engaged in this same task. These technical discussions are complemented with Appendices where appropriate.

Not Available

1984-10-01T23:59:59.000Z

408

Brookhaven National Laboratory 2008 Site Environment Report Volume 1  

SciTech Connect (OSTI)

Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in this volume in Chapter 7, Groundwater Protection. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the full report.

Brookhaven National Laboratory

2009-10-01T23:59:59.000Z

409

International Linear Collider Technical Design Report (Volumes 1 through 4)  

SciTech Connect (OSTI)

The design report consists of four volumes: Volume 1, Executive Summary; Volume 2, Physics; Volume 3, Accelerator (Part I, R and D in the Technical Design Phase, and Part II, Baseline Design); and Volume 4, Detectors.

Harrison M.

2013-03-27T23:59:59.000Z

410

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

and Judkoff, R. 2002. IEA HVAC BESTEST volume 1, Technicaland Judkoff, R. 2004. IEA HVAC BESTEST volume 2, TechnicalOF INNOVATIVE INTEGRATED HVAC SYSTEMS IN BUILDINGS Marija

Trcka, Marija

2010-01-01T23:59:59.000Z

411

Operational Waste Volume Projection  

SciTech Connect (OSTI)

Waste receipts to the double-shell tank system are analyzed and wastes through the year 2015 are projected based on generation trends of the past 12 months. A computer simulation of site operations is performed, which results in projections of tank fill schedules, tank transfers, evaporator operations, tank retrieval, and aging waste tank usage. This projection incorporates current budget planning and the clean-up schedule of the Tri-Party Agreement. Assumptions were current as of June. 2000.

STRODE, J.N.

2000-08-28T23:59:59.000Z

412

Operational waste volume projection  

SciTech Connect (OSTI)

Waste receipts to the double-shell tank system are analyzed and wastes through the year 2015 are projected based on generation trends of the past 12 months. A computer simulation of site operations is performed, which results in projections of tank fill schedules, tank transfers, evaporator operations, tank retrieval, and aging waste tank usage. This projection incorporates current budget planning and the clean-up schedule of the Tri-Party Agreement. Assumptions were current as of June 1996.

Koreski, G.M.

1996-09-20T23:59:59.000Z

413

Solid waste operations complex W-113: Preliminary design report. Volume I  

SciTech Connect (OSTI)

This document is Volume I of a Preliminary Design Report (Title I) for the Solid Waste Retrieval Facilities-Phase I (Project W-113) at Hanford. It was prepared by Raytheon and BNFL Inc. and submitted to Westinghouse Hanford Company in January 1995. This volume provides a project overview and a discussion of the waste handling systems, the data acquisition and control systems, the building systems, and the site/building structure.

NONE

1995-01-01T23:59:59.000Z

414

SAPHIRE 8 Volume 2 - Technical Reference  

SciTech Connect (OSTI)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of computer programs that were developed to create and analyze probabilistic risk assessment (PRAs). Herein information is provided on the principles used in the construction and operation of Version 8.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, Workspace algorithms, cut set "recovery," end state manipulation, and use of "compound events."

C. L. Smith; S. T. Wood; W. J. Galyean; J. A. Schroeder; M. B. Sattison

2011-03-01T23:59:59.000Z

415

Film Collection Volume Two  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series toESnet4:EpitaxialtransatlanticUnified ForcesFile Systems File

416

Seismic Volume Visualization for Horizon Extraction Daniel Patel  

E-Print Network [OSTI]

Seismic Volume Visualization for Horizon Extraction Daniel Patel Christian Michelsen Research¨oller § Institute of Computer Graphics and Algorithms, Vienna University of Technology, Austria ABSTRACT Seismic present a novel system for rapidly interpret- ing and visualizing seismic volumetric data. First we

417

Parallel High-Resolution Finite Volume Simulation of Particulate Processes  

E-Print Network [OSTI]

these methods is verified by application to PBMs for (1) aerosol coagulation and condensation, (2) the formation, coagulation, crystallization, distributed parameter systems, numerical analysis Introduction Particulate, in crystallization, x is the size of crystals measured by length or volume, f(x,t) is the crystal size distribution

Braatz, Richard D.

418

Which BPS baryons minimize volume?  

SciTech Connect (OSTI)

A Bogomol'nyi-Prasad-Sommerfield (BPS) 3-cycle in a Sasaki-Einstein 5-manifold in general does not minimize volume in its homology class, as we illustrate with several examples of nonminimal volume BPS cycles on the 5-manifolds Y{sup p,q}. Instead they minimize the energy of a wrapping D-brane, extremizing a generalized calibration. We present this generalized calibration and demonstrate that it reproduces both the Born-Infeld and the Wess-Zumino parts of the D3-brane energy.

Evslin, Jarah; Kuperstein, Stanislav [Scuola Internazionale Superiore di Studi Avanzati (SISSA), Strada Costiera, Via Beirut n.2-4, 34013 Trieste (Italy); Theoretische Natuurkunde, Vrije Universiteit Brussel and The International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium)

2009-02-15T23:59:59.000Z

419

Large volume high-pressure cell with supported moissanite anvils  

SciTech Connect (OSTI)

The recently developed moissanite anvil cell (MAC) has become a useful device for achieving both high-pressure and large sample volume in an anvil cell. We describe two improvements in the basic design of the MAC. First, the loading environment has been optimized by centering the load. Second, a variety of supported systems have been examined to provide anvil stability at high loads with large anvils. Sample volumes that are nearly three orders magnitude greater than allowed by conventional diamond anvil cells can be pressurized and characterized at {approx}50 GPa.

Xu, J.; Mao, H.-k.; Hemley, R.J.; Hines , E. (CIW/GL)

2010-11-16T23:59:59.000Z

420

Solid waste 30-year volume summary  

SciTech Connect (OSTI)

A 30-year forecast of the solid waste volumes to be generated or received at the US Department of Energy Hanford Site is described in this report. The volumes described are low-level mixed waste (LLMW) and transuranic/transuranic mixed (TRU/TRUM) waste that will require treatment, storage, and disposal at Hanford`s Solid Waste Operations Complex (SWOC) during the 30-year period from FY 1994 through FY 2023. The data used to complete this document were collected from onsite and offsite waste generators who currently, or are planning to, ship solid wastes to the Hanford Site. An analysis of the data suggests that over 300,000 m{sup 3} of LLMW and TRU/TRUM waste will be managed at Hanford`s SWOC over the next 30 years. An extensive effort was made this year to collect this information. The 1993 solid waste forecast was used as a starting point, which identified approximately 100,000 m{sup 3} of LLMW and TRU/TRUM waste to be sent to the SWOC. After analyzing the forecast waste volume, it was determined that additional waste was expected from the tank waste remediation system (TWRS), onsite decontamination and decommissioning (D&D) activities, and onsite remedial action (RA) activities. Data presented in this report establish a starting point for solid waste management planning. It is recognized that forecast estimates will vary (typically increasing) as facility planning and missions continue to change and become better defined, but the information presented still provides useful insight into Hanford`s future solid waste management requirements.

Valero, O.J.; Armacost, L.L.; DeForest, T.J.; Templeton, K.J.; Williams, N.C.

1994-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Probing cell-free gene expression noise in femtoliter volumes  

SciTech Connect (OSTI)

Cell-free systems offer a simplified and flexible context that enables important biological reactions while removing complicating factors such as fitness, division, and mutation that are associated with living cells. However, cell-free expression in unconfined spaces is missing important elements of expression in living cells. In particular, the small volume of living cells can give rise to significant stochastic effects, which are negligible in bulk cell-free reactions. Here, we confine cell-free gene expression reactions to cell relevant 20 fL volumes (between the volumes of E. coli and S. cerevisiae), in polydimethylsiloxane (PDMS) containers. We demonstrate that expression efficiency varies widely at this volume, and we analyze gene expression noise. Noise analysis reveals signatures of translational bursting while noise dynamics suggest that overall cell-free expression is limited by a diminishing translation rate. In addition to offering a unique approach to understanding noise in gene circuits, our work contributes to a deeper understanding of the biophysical properties of cell-free expression systems, thus aiding efforts to harness cell-free systems for synthetic biology applications.

Karig, David K [ORNL; Jung, Seung-Yong [ORNL; Srijanto, Bernadeta R [ORNL; Collier, Pat [ORNL; Simpson, Michael L [ORNL

2013-01-01T23:59:59.000Z

422

Design of a digital dissertation information management system  

E-Print Network [OSTI]

Gobinda G. Chowdhury,G.G.C. Program: Electronic Library and Information Systems Volume 36 pp 152-165

Gobinda G.; Chowdhury, G.G.C.; Program: Electronic Library and Information Systems Volume 36 pp 152-165 [More Details

423

Bistability: Requirements on Cell-Volume, Protein Diffusion, and Thermodynamics  

E-Print Network [OSTI]

Bistability is considered wide-spread among bacteria and eukaryotic cells, useful e.g. for enzyme induction, bet hedging, and epigenetic switching. However, this phenomenon has mostly been described with deterministic dynamic or well-mixed stochastic models. Here, we map known biological bistable systems onto the well-characterized biochemical Schloegl model, using analytical calculations and stochastic spatio-temporal simulations. In addition to network architecture and strong thermodynamic driving away from equilibrium, we show that bistability requires fine-tuning towards small cell volumes (or compartments) and fast protein diffusion (well mixing). Bistability is thus fragile and hence may be restricted to small bacteria and eukaryotic nuclei, with switching triggered by volume changes during the cell cycle. For large volumes, single cells generally loose their ability for bistable switching and instead undergo a first-order phase transition.

Robert G. Endres

2015-03-06T23:59:59.000Z

424

Site Environmental Report for 2011, Volumes 1& 2  

SciTech Connect (OSTI)

The Site Environmental Report for 2011 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year (CY) 2011. Throughout this report, “Berkeley Lab” or “LBNL” refers both to (1) the multiprogram scientific facility the UC manages and operates on the 202-acre university-owned site located in the hills above the UC Berkeley campus, and the site itself, and (2) the UC as managing and operating contractor for Ernest Orlando Lawrence Berkeley National Laboratory. The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that include an overview of LBNL, a discussion of its Environmental Management System (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities.

Baskin, David; Bauters, Tim; Borglin, Ned; Fox, Robert; Horst, Blair; Jelinski, John; Lackner, Ginny; Philliber, Jeff; Rothermich, Nancy; Thorson, Patrick; Wahl, Linnea; Xu, Suying

2012-09-12T23:59:59.000Z

425

A Magnification Lens for Interactive Volume Visualization  

SciTech Connect (OSTI)

Volume visualization of large data sets suffers from the same problem that many other visualization modalities suffer from: either one can visualize the entire data set and lose small details or visualize a small region and lose the context. In this paper, they present a magnification lens technique for volume visualization. While the notion of a magnification-lens is not new, and other techniques attempt to simulate the physical properties of a magnifying lens, their contribution is in developing a magnification lens that is fast, can be implemented using a fairly small software overhead, and has a natural, intuitive appearance. The issue with magnification lens is the border, or transition, region. The lens center and exterior have a constant zoom factor, and are simple to render. It is the border region that blends between the external and interior magnification, and has a non-constant magnification. They use the perspective-correct textures capability, available in most current graphics systems, to produce a lens with a tessellated border region that approximates linear compression with respect to the radius of the magnification lens. They discuss how a cubic border can mitigate the discontinuities resulting from the use of a linear function, without significant performance loss. They discuss various issues concerning development of a three-dimensional magnification lens.

LaMar, E; Hamann, B; Joy, K I

2001-07-19T23:59:59.000Z

426

Petroleum Supply Annual 2005, Volume 1  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

Supply Annual 2005, Volume 1 Released: October 23, 2006 Petroleum Supply Annual 2005, Volume 1 --- All Tables in PDF (1.0 MB) CSV XLS --- All CSV and XLS files contained in a...

427

Statistically Equivalent Representative Volume Elements for Unidirectional  

E-Print Network [OSTI]

Statistically Equivalent Representative Volume Elements for Unidirectional Composite the statistically equivalent representative volume element (SERVE) are proposed for fiber-reinforced microstructures using a bilinear cohesive zone law. As introduced in the first article, a combination of statistical

Ghosh, Somnath

428

Implementation of RFID in a low volume high flexibility assembly plant : item-level tagging  

E-Print Network [OSTI]

The implementation of an RFID checkpoint system in a low volume high flexibility assembly plant, aimed at tracking the flow of parts within the facility, was studied. A pilot revealed the suitability of the technology to ...

Koniski, Cyril (Cyril A.)

2010-01-01T23:59:59.000Z

429

Proceedings of the 6. international conference on stability and handling of liquid fuels. Volume 1  

SciTech Connect (OSTI)

Volume 1 of these proceedings contain 29 papers related to aviation fuels and long term and strategic storage. Studies investigated fuel contamination, separation processes, measurement techniques, thermal stability, compatibility with fuel system materials, oxidation reactions, and degradation during storage.

Giles, H.N. [ed.] [Deputy Assistant Secretary for Strategic Petroleum Reserve, Washington, DC (United States). Operations and Readiness Office

1998-12-01T23:59:59.000Z

430

E-Print Network 3.0 - automatic target volume Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2005 2010 2015 Usable Specific Energy (kW hr kg) 1.3 0.8 10-17 15... tank, 500k production volume, optimized carbon, health monitored storage system. 12;Composite Pressure...

431

Development of Approach to Estimate Volume Fraction of Multiphase Material Using Dielectrics  

E-Print Network [OSTI]

without any assumptions. Also, the system identification was used iteratively to solve for dielectric parameters and volume fraction at each step. As the validation performed to verify the viability of the new approach using soil mixture and portland...

Lee, Sang Ick

2010-07-14T23:59:59.000Z

432

PAGE 12 MONEY TALK$ VOLUME 5 LINK TO YOUR FINANCIAL AID INFORMATION THROUGH MIX  

E-Print Network [OSTI]

PAGE 12 MONEY TALK$ VOLUME 5 LINK TO YOUR FINANCIAL AID INFORMATION THROUGH MIX The Financial Aid system 12 Meet the Financial Aid Office Staff 5 Purchasing Your Text- books 11 Inside this issue: Money

Mohaghegh, Shahab

433

Page 12 MONEY TALK$ VOLUME 5 LINK TO YOUR FINANCIAL AID INFORMATION THROUGH MIX  

E-Print Network [OSTI]

Page 12 MONEY TALK$ VOLUME 5 LINK TO YOUR FINANCIAL AID INFORMATION THROUGH MIX The Financial Aid on the MIX system p 12 Inside this issue: Money Talk$ West Virginia University Financial Aid and Scholars

Mohaghegh, Shahab

434

Verifying Volume Rendering Using Discretization Error Analysis  

E-Print Network [OSTI]

Verifying Volume Rendering Using Discretization Error Analysis Tiago Etiene, Daniel Jo¨nsson, Timo--We propose an approach for verification of volume rendering correctness based on an analysis of the volume rendering integral, the basis of most DVR algorithms. With respect to the most common discretization

Kirby, Mike

435

Effects of High-Altitude Electromagnetic Pulse (HEMP) on the Northern Telecom Inc. DMS-100 (trademark) switch. Volume 2. Test program. Final report  

SciTech Connect (OSTI)

This report is part of a three volume set that presents the results of simulated High-Altitude Electromagnetic Pulse (HEMP) testing of a DMS-100 Switching System. This volume is a detailed description of the test procedures, test results, and the mitigation alternatives evaluated. This volume also presents a discussion of the conclusion and recommendations of the program.

Not Available

1988-09-01T23:59:59.000Z

436

Thermodynamics and fluctuations of conserved charges in Hadron Resonance Gas model in finite volume  

E-Print Network [OSTI]

The thermodynamics of hot and dense matter created in heavy-ion collision experiments are usually studied as a system of infinite volume. Here we report on possible effects for considering a finite system size for such matter in the framework of the Hadron Resonance Gas model. The bulk thermodynamic variables as well as the fluctuations of conserved charges are considered. We find that the finite size effects are insignificant once the observables are scaled with the respective volumes. The only substantial effect is found in the fluctuations of electric charge which may therefore be used to extract information about the volume of fireball created in heavy-ion collision experiments.

Bhattacharyya, Abhijit; Samanta, Subhasis; Sur, Subrata

2015-01-01T23:59:59.000Z

437

Development of Optimization Tool for Air Conditioning System Operation  

E-Print Network [OSTI]

Operations, Berlin, Germany, October 20-22, 2008 Outside air temperature and the absolute air humidity are predicted by the Auto-regressive Integrated Moving Average (ARIMA) model [1],[2]. The solar radiation on a horizontal surface... of the error margin Energy Consumption (set value A) Energy Consumption (set value B) ESL-IC-08-10-55 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 J VAV unit is also operated under...

Sumiyoshi, D.; Akashi, Y.

438

Waste minimization handbook, Volume 1  

SciTech Connect (OSTI)

This technical guide presents various methods used by industry to minimize low-level radioactive waste (LLW) generated during decommissioning and decontamination (D and D) activities. Such activities generate significant amounts of LLW during their operations. Waste minimization refers to any measure, procedure, or technique that reduces the amount of waste generated during a specific operation or project. Preventive waste minimization techniques implemented when a project is initiated can significantly reduce waste. Techniques implemented during decontamination activities reduce the cost of decommissioning. The application of waste minimization techniques is not limited to D and D activities; it is also useful during any phase of a facility`s life cycle. This compendium will be supplemented with a second volume of abstracts of hundreds of papers related to minimizing low-level nuclear waste. This second volume is expected to be released in late 1996.

Boing, L.E.; Coffey, M.J.

1995-12-01T23:59:59.000Z

439

Electric and Magnetic Fields (EMF) RAPID Program Engineering Project 8: FINAL REPORT, Evaluation of Field Reduction Technologies, Volume 1 (Report) and Volume 2 (Appendices)  

SciTech Connect (OSTI)

This draft report consists of two volumes. Volume 1, the main body, contains an introducto~ sectionj an overview of magnetic fields sectio~ and field reduction technology evaluation section. Magnetic field reduction methods are evalpated for transmission lines, distribution Iines,sulxtations, building wiring applkmd machinery, and transportation systems. The evaluation considers effectiveness, co% and other ftiors. Volume 2 contains five appendices, Append~ A presents magnetic field shielding information. Appendices B and C present design assumptions and magnetic field plots for transmission and distribution lines, respectively. Appendices D and E present cost estimate details for transmission and distribution limes, respectively.

Commonwealth Associates, Inc.; IIT Research Institute

1997-08-01T23:59:59.000Z

440

Study of the 1991 unaccounted-for gas volume at the Southern California Gas Company. Final report, January 1991-December 1992. Volume 2. Accounting  

SciTech Connect (OSTI)

As part of a study of unaccounted-for gas (UAF), performed by the Southern California Gas Company (SoCalGas), volume II of the six-volume set presents the results of the accounting portion, including sections on accounting adjustments and company-use gas. It identifies enhancements to accounting practices that make records more accurately reflect the physical activity occurring in the system. The result is an accounting record of gas volumes received and delivered which have been adjusted for the enhancements, and exclude accounting estimates and prior period adjustments.

Meshkati, S.; Groot, J.; Law, E.; Rudshagen, C.; Yevchak, S.

1993-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Proceedings of the Twenty-First Water Reactor Safety Information Meeting: Volume 1, Plenary session; Advanced reactor research; advanced control system technology; advanced instrumentation and control hardware; human factors research; probabilistic risk assessment topics; thermal hydraulics; thermal hydraulic research for advanced passive LWRs  

SciTech Connect (OSTI)

This three-volume report contains 90 papers out of the 102 that were presented at the Twenty-First Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, during the week of October 25--27, 1993. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Germany, Japan, Russia, Switzerland, Taiwan, and United Kingdom. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. Individual papers have been cataloged separately. This document, Volume 1 covers the following topics: Advanced Reactor Research; Advanced Instrumentation and Control Hardware; Advanced Control System Technology; Human Factors Research; Probabilistic Risk Assessment Topics; Thermal Hydraulics; and Thermal Hydraulic Research for Advanced Passive Light Water Reactors.

Monteleone, S. [Brookhaven National Lab., Upton, NY (United States)] [comp.

1994-04-01T23:59:59.000Z

442

MACHINE CONTEST MACHINE VOLUME WORKSHEET  

E-Print Network [OSTI]

MACHINE CONTEST® MACHINE VOLUME WORKSHEET Note: Each square is 1' x 1' (0.3 m x 0.3 m) (Official the footprint of your machine NOTE: If any part of the machine falls within a square, you must count the entire: _______________ (choose one: ft2 or m2 ) STEP 3: Measure the height of your machine. NOTE: The maximum height is 8' (2.4 m

Yener, Aylin

443

Petroleum supply annual 1994. Volume 1  

SciTech Connect (OSTI)

The Petroleum Supply Annual (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1994 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains four sections: Summary Statistics, Detailed Statistics, Refinery Capacity, and Oxygenate Capacity each with final annual data. The second volume contains final statistics for each month of 1994, and replaces data previously published in the Petroleum Supply Monthly (PSM). The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. Below is a description of each section in Volume 1 of the PSA.

NONE

1995-05-22T23:59:59.000Z

444

Petroleum supply annual 1993. Volume 1  

SciTech Connect (OSTI)

The Petroleum Supply Annual (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1993 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains four sections: Summary Statistics, Detailed Statistics, Refinery Capacity, and Oxygenate Capacity each with final annual data. The second volume contains final statistics for each month of 1993, and replaces data previously published in the Petroleum Supply Monthly (PSM). The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. Below is a description of each section in Volume 1 of the PSA.

Not Available

1994-06-01T23:59:59.000Z

445

Volumes  

Gasoline and Diesel Fuel Update (EIA)

W 803.9 1,360.3 214.2 2,378.3 W W 172.8 133.2 - 305.9 See footnotes at end of table. 220 Energy Information AdministrationPetroleum Marketing Annual 1999 Table 43. Refiner Motor...

446

Volumes  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

W W 830.4 W W 2,295.3 W W 190.9 133.6 - 324.5 See footnotes at end of table. 220 Energy Information AdministrationPetroleum Marketing Annual 1998 Table 43. Refiner Motor...

447

Volumes  

U.S. Energy Information Administration (EIA) Indexed Site

W 872.9 1,737.8 282.7 2,893.4 W W 132.1 117.6 - 249.7 See footnotes at end of table. 220 Energy Information AdministrationPetroleum Marketing Annual 2002 Table 43. Refiner Motor...

448

Volumes  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

W NA W 1,666.1 W 2,880.1 NA W 134.2 125.5 - 259.7 See footnotes at end of table. 220 Energy Information AdministrationPetroleum Marketing Annual 2001 Table 43. Refiner Motor...

449

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER 18 P

450

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER 18

451

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER 180,

452

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER

453

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER3 P H

454

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER3 P H6

455

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER3 P

456

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER3 P8,

457

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER3

458

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER318 P

459

VOLUME  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear SecurityTensile Strain Switched Ferromagnetism inS-4500II Field EmissionFunctionalPortalV1 - March8, NUMBER318

460

Volumes  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProved ReservesFeet)per Thousand28Decreases (BillionSeparation 2,37809,369.5

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Volumes  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProved ReservesFeet)per Thousand28Decreases (BillionSeparation

462

Volumes  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProved ReservesFeet)per Thousand28Decreases (BillionSeparation41,706.6 42,867.4

463

Volumes  

U.S. Energy Information Administration (EIA) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative FuelsTotal" (Percent) Type: Sulfur ContentMwH)","RES_CONS4,369,090 4,367,318 4,367,470

464

A Multiresolution Image Cache for Volume Rendering  

SciTech Connect (OSTI)

The authors discuss the techniques and implementation details of the shared-memory image caching system for volume visualization and iso-surface rendering. One of the goals of the system is to decouple image generation from image display. This is done by maintaining a set of impostors for interactive display while the production of the impostor imagery is performed by a set of parallel, background processes. The system introduces a caching basis that is free of the gap/overlap artifacts of earlier caching techniques. instead of placing impostors at fixed, pre-defined positions in world space, the technique is to adaptively place impostors relative to the camera viewpoint. The positions translate with the camera but stay aligned to the data; i.e., the positions translate, but do not rotate, with the camera. The viewing transformation is factored into a translation transformation and a rotation transformation. The impostor imagery is generated using just the translation transformation and visible impostors are displayed using just the rotation transformation. Displayed image quality is improved by increasing the number of impostors and the frequency that impostors are re-rendering is improved by decreasing the number of impostors.

LaMar, E; Pascucci, V

2003-02-27T23:59:59.000Z

465

Review of Literature on Terminal Box Control, Occupancy Sensing Technology and Multi-zone Demand Control Ventilation (DCV)  

SciTech Connect (OSTI)

This report presents an overall review of the standard requirement, the terminal box control, occupancy sensing technology and DCV. There is system-specific guidance for single-zone systems, but DCV application guidance for multi-zone variable air volume (VAV) systems is not available. No real-world implementation case studies have been found using the CO2-based DCV. The review results also show that the constant minimum air flow set point causes excessive fan power consumption and potential simultaneous heating and cooling. Occupancy-based control (OBC) is needed for the terminal box in order to achieve deep energy savings. Key to OBC is a technology for sensing the actual occupancy of the zone served in real time. Several technologies show promise, but none currently fully meets the need with adequate accuracy and sufficiently low cost.

Liu, Guopeng; Dasu, Aravind R.; Zhang, Jian

2012-03-01T23:59:59.000Z

466

Nuclear criticality safety experiments, calculations, and analyses: 1958 to 1982. Volume 1. Lookup tables  

SciTech Connect (OSTI)

This compilation contains 688 complete summaries of papers on nuclear criticality safety as presented at meetings of the American Nuclear Society (ANS). The selected papers contain criticality parameters for fissile materials derived from experiments and calculations, as well as criticality safety analyses for fissile material processing, transport, and storage. The compilation was developed as a component of the Nuclear Criticality Information System (NCIS) now under development at the Lawrence Livermore National Laboratory. The compilation is presented in two volumes: Volume 1 contains a directory to the ANS Transaction volume and page number where each summary was originally published, the author concordance, and the subject concordance derived from the keyphrases in titles. Volume 2 contains - in chronological order - the full-text summaries, reproduced here by permission of the American Nuclear Society from their Transactions, volumes 1-41.

Koponen, B.L.; Hampel, V.E.

1982-10-21T23:59:59.000Z

467

State of the art review of radioactive waste volume reduction techniques for commercial nuclear power plants  

SciTech Connect (OSTI)

A review is made of the state of the art of volume reduction techniques for low level liquid and solid radioactive wastes produced as a result of: (1) operation of commercial nuclear power plants, (2) storage of spent fuel in away-from-reactor facilities, and (3) decontamination/decommissioning of commercial nuclear power plants. The types of wastes and their chemical, physical, and radiological characteristics are identified. Methods used by industry for processing radioactive wastes are reviewed and compared to the new techniques for processing and reducing the volume of radioactive wastes. A detailed system description and report on operating experiences follow for each of the new volume reduction techniques. In addition, descriptions of volume reduction methods presently under development are provided. The Appendix records data collected during site surveys of vendor facilities and operating power plants. A Bibliography is provided for each of the various volume reduction techniques discussed in the report.

Not Available

1980-04-01T23:59:59.000Z

468

Technology of high-level nuclear waste disposal. Advances in the science and engineering of the management of high-level nuclear wastes. Volume 1  

SciTech Connect (OSTI)

The papers in this volume cover the following subjects: waste isolation and the natural geohydrologic system; repository perturbations of the natural system; radionuclide migration through the natural system; and repository design technology. Individual papers are abstracted.

Hofmann, P.L.; Breslin, J.J. (eds.)

1981-01-01T23:59:59.000Z

469

Method and apparatus for probing relative volume fractions  

DOE Patents [OSTI]

A relative volume fraction probe particularly for use in a multiphase fluid system includes two parallel conductive paths defining therebetween a sample zone within the system. A generating unit generates time varying electrical signals which are inserted into one of the two parallel conductive paths. A time domain reflectometer receives the time varying electrical signals returned by the second of the two parallel conductive paths and, responsive thereto, outputs a curve of impedance versus distance. An analysis unit then calculates the area under the curve, subtracts the calculated area from an area produced when the sample zone consists entirely of material of a first fluid phase, and divides this calculated difference by the difference between an area produced when the sample zone consists entirely of material of the first fluid phase and an area produced when the sample zone consists entirely of material of a second fluid phase. The result is the volume fraction. 9 figs.

Jandrasits, W.G.; Kikta, T.J.

1998-03-17T23:59:59.000Z

470

VOLUME 88, NUMBER 25 P H Y S I C A L R E V I E W L E T T E R S 24 JUNE 2002 Dynamics of an Inhomogeneously Coarse Grained Multiscale System  

E-Print Network [OSTI]

of an Inhomogeneously Coarse Grained Multiscale System Stefano Curtarolo1 and Gerbrand Ceder1,2 1 Department degree of freedom [1]. Monte Carlo simulations can then be used to simulate the kinetic evolution

Curtarolo, Stefano

471

Analysis of concentrating PV-T systems for the commercial/industrial sector. Volume II. PV-T state-of-the-art survey and site/application pair selection and analysis  

SciTech Connect (OSTI)

As part of a project to develop feasibility assessments, design procedures, and reference designs for total energy systems that could use actively cooled concentrating photovoltaic collectors, a survey was conducted to provide an overview of available photovoltaic-thermal (PV-T) technology. General issues associated with the design and installation of a PV-T system are identified. Electrical and thermal efficiencies for the line-focus Fresnel, the linear parabolic trough, and the point-focus Fresnel collectors are specified as a function of operating temperature, ambient temperature, and insolation. For current PV-T technologies, the line-focus Fresnel collector proved to have the highest thermal and electrical efficiencies, lowest array cost, and lowest land area requirement. But a separate feasibility analysis involving 11 site/application pairs showed that for most applications, the cost of the photovoltaic portion of a PV-T system is not recovered through the displacement of an electrical load, and use of a thermal-only system to displace the thermal load would be a more economical alternative. PV-T systems are not feasible for applications that have a small thermal load, a large steam requirement, or a high load return temperature. SAND82-7157/3 identifies the technical issues involved in designing a photovoltaic-thermal system and provides guidance for resolving such issues. Detailed PV-T system designs for three selected applications and the results of a trade-off study for these applications are presented in SAND82-7157/4. A summary of the major results of this entire study and conclusions concerning PV-T systems and applications is presented in SAND82-7157/1.

Schwinkendorf, W.E.

1984-09-01T23:59:59.000Z

472

Commercial thermal distribution systems, Final report for CIEE/CEC  

E-Print Network [OSTI]

air-volume HVAC systems, static pressures across theIn VAY HVAC systems, the static pressures may likely changefor the Static Pressure Analysis Tool are: • HVAC schedule

Xu, T.

2011-01-01T23:59:59.000Z

473

aircraft system concept: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

aircraft conducting High Volume Valasek, John 4 Aircraft System Identification Using Artificial Neural Networks Engineering Websites Summary: Aircraft System Identification Using...

474

Scuttlebutt Volume 2, No. 4  

E-Print Network [OSTI]

?s Sunshine Award & Crewmember of the Year Award. Polls close on Friday, July 18. Crewmembers may vote in the official site, http://groups.yahoo.com/group/uss-southerncrossawards/. The results Will be announced at the Summit. Summit Event Venues... of our good friends in Adelaide, reacquaint myself with my ?old? mates and make friends with new ones. See you in SA. COL Bruce O?Brien Commanding Officer Newsletter Publisher http://www.uss-southerncross.com/ July / August 2008 Volume 2, Issue 4...

2008-01-01T23:59:59.000Z

475

Scuttlebutt Volume 2, No. 1  

E-Print Network [OSTI]

, of the USS Genesis. To CPT Kieran Bock and his crew, the officers and crew of the Southern Cross send their very best wishes and congratulations, and we wish them fair seas and LOTS of stars to follow. The ScuttleButt Volume 2, Issue 1 5 USS Atlantis... will be forwarded separately to each individual member. Please forward any enquiries to the Intel Officer - ENS Ashley Walker on alwalk78@optusnet.com.au. ENS Ashley Walker Operations Intelligence Officer Welcoming New Crewmembers Savannah Clark Daniel...

2008-01-01T23:59:59.000Z

476

Volume 4 | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment of Dept.| Department ofEducationVirgin4, 2009InsightsVolume 4

477

Scuttlebutt Volume 1, No. 8  

E-Print Network [OSTI]

http://www.uss-southerncross.com/news.htm http://www.uss-southerncross.com/ ARMAGEDDON AND NEW WORLDS 5 November/December 2007 Volume 1, Issue 8 2 Vol.1 Issue 8 ScuttleButt ScuttleButt is the official bimonthly publication of the USS Southern... 5. Club 360, BioShock Operations 6. Ship?s Muster Tactical/Security 8. Armageddon by Matt Tuting 9. Region 11 Convention Listing Communications 10. The Klingon Language Institute 11. The USS Southern Cross' writing group - The Writer...

2007-01-01T23:59:59.000Z

478

Scuttlebutt Volume 2, No. 3  

E-Print Network [OSTI]

. From The Bridge 4. The Editor's Corner 5. The X/O's Desk 6. Club 360 7. In Memoriam ? Lauretta Gal 28. The Southern Cross Press Operations 5. Ship's Muster Medical 8. The Psyche Report Communications 9. Followup: Spiderwick... and Pieces 5The ScuttleButt Volume 2, Issue 3 The X/O?s Desk Attention all Stations: Hello and welcome to my little area for voicing my ideas or opinions. Well not much to talk about this time things have been quite I know Bruce has booked his airfare...

2008-01-01T23:59:59.000Z

479

Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 2, Technical basis  

SciTech Connect (OSTI)

Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume, Volume 2, contains the technical basis for the 1992 PA. Specifically, it describes the conceptual basis for consequence modeling and the PA methodology, including the selection of scenarios for analysis, the determination of scenario probabilities, and the estimation of scenario consequences using a Monte Carlo technique and a linked system of computational models. Additional information about the 1992 PA is provided in other volumes. Volume I contains an overview of WIPP PA and results of a preliminary comparison with the long-term requirements of the EPA`s Environmental Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Volume 3 contains the reference data base and values for input parameters used in consequence and probability modeling. Volume 4 contains uncertainty and sensitivity analyses related to the preliminary comparison with 40 CFR 191B. Volume 5 contains uncertainty and sensitivity analyses of gas and brine migration for undisturbed performance. Finally, guidance derived from the entire 1992 PA is presented in Volume 6.

Not Available

1992-12-01T23:59:59.000Z

480

Petroleum supply annual 1995: Volume 1  

SciTech Connect (OSTI)

The {ital Petroleum Supply Annual} contains information on supply and disposition of crude oil and petroleum products. It reflects data collected from the petroleum industry during 1995 through monthly surveys, and it is divided into 2 volumes. This volume contains three sections: summary statistics, detailed statistics, and selected refinery statistics, each with final annual data. (The other volume contains final statistics for each month and replaces data previously published in the {ital Petroleum Supply Monthly}).

NONE

1996-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "volume vav system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Fault detection in an air-handling unit using residual and recursive parameter identification methods  

SciTech Connect (OSTI)

A scheme for detecting faults in an air-handling unit using residual and parameter identification methods is presented. Faults can be detected by comparing the normal or expected operating condition data with the abnormal, measured data using residuals. Faults can also be detected by examining unmeasurable parameter changes in a model of a controlled system using a system parameter identification technique. In this study, autoregressive moving average with exogenous input (ARMAX) and autoregressive with exogenous input (ARX) models with both single-input/single-output (SISO) and multi-input/single-output (MISO) structures are examined. Model parameters are determined using the Kalman filter recursive identification method. This approach is tested using experimental data from a laboratory`s variable-air-volume (VAV) air-handling unit operated with and without faults.

Lee, W.Y. [Korea Inst. of Energy Research, Taejon (Korea, Republic of); Park, C.; Kelly, G.E. [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

1996-11-01T23:59:59.000Z

482

Petroleum supply annual 1998: Volume 1  

SciTech Connect (OSTI)

The ``Petroleum Supply Annual`` (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1998 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains three sections: Summary Statistics, Detailed Statistics, and Refinery Statistics; each with final annual data. The second volume contains final statistics for each month of 1998, and replaces data previously published in the PSA. The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. 16 figs., 59 tabs.

NONE

1999-06-01T23:59:59.000Z

483

Petroleum supply annual, 1997. Volume 1  

SciTech Connect (OSTI)

The Petroleum Supply Annual (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1997 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains three sections: Summary Statistics, Detailed Statistics, and Refinery Statistics; each with final annual data. The second volume contains final statistics for each month of 1997, and replaces data previously published in the Petroleum Supply Monthly (PSM). The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. 16 figs., 48 tabs.

NONE

1998-06-01T23:59:59.000Z

484

Volume, Number of Shipments Surpass Goals  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Laboratory," said Pete Maggiore, assistant manager for environmental operations at the NNSA Los Alamos Site Office. "We exceeded our goals and are on track to double both volume...

485

Water Quality Program, Volume 2 (Alabama)  

Broader source: Energy.gov [DOE]

This volume of the water quality program mainly deals with Technical Standards, Corrective Action Requirements and Financial Responsibility for Owners and Operators of Underground Storage Tanks....

486

Volume reduction of hot cell plastic wastes  

SciTech Connect (OSTI)

The disposal of radioactively-contaminated solid wastes has become a national crisis. In such circumstances, it is imperative that this waste be reduced to minimum volume and be packaged to prevent pollution of the environment. The majority of the solid waste generated at the hot cell under consideration is plastic lab ware. Cutting this waste into small pieces with a hot wire technique reduced the volume 66%. Melting the waste, although more time consuming, reduced the volume 90%. The hot wire technique can also be used to cut up damaged master slave manipulator boots, greatly reducing their disposal volume.

Dykes, F W; Henscheid, J P; Lewis, L C; Lundholm, C W; Nicklas, J H

1989-09-19T23:59:59.000Z

487

ARE Update Volume 13, Number 4  

E-Print Network [OSTI]

Use of U.S. Croplands for Biofuels In- creases Greenhousea mini- mum volume of biofuels and requires a nationalper unit of various biofuels. For example, corn ethanol

2010-01-01T23:59:59.000Z

488

Rural Intelligent Transportation Systems  

E-Print Network [OSTI]

Rural Intelligent Transportation Systems In a technical session at the 2011 NACE conference, Dennis Foderberg of SEH Inc. discussed intelligent transportation systems (ITS) developed by SEH in collaboration with Network Transportation Technologies, Inc. These systems address the problem of crashes on low-volume roads

Minnesota, University of

489

Ironmaking conference proceedings. Volume 54  

SciTech Connect (OSTI)

The technical presentations at this conference displayed a renewed sense of viability of the coke and ironmaking community. In addition, many of the papers show that the environmental aspects of ironmaking are being integrated into day-to-day operations rather than being thought of as separate responsibilities. This volume contains 68 papers divided into the following sections: Blast furnace injection; Blast furnace fundamental studies; Blast furnace general; Blast furnace repairs/rebuilds/modernization; Process control techniques for blast furnaces; Cokemaking general; Cokemaking environmental; Coke--by-products--plant operations; Coal and coke research; Battery operations; Pelletizing; Direct reduction and smelting; and Sintering. Most of the papers have been processed separately for inclusion on the data base.

NONE

1995-12-01T23:59:59.000Z

490

Capturing Data Uncertainty in High-Volume Stream Processing  

E-Print Network [OSTI]

We present the design and development of a data stream system that captures data uncertainty from data collection to query processing to final result generation. Our system focuses on data that is naturally modeled as continuous random variables. For such data, our system employs an approach grounded in probability and statistical theory to capture data uncertainty and integrates this approach into high-volume stream processing. The first component of our system captures uncertainty of raw data streams from sensing devices. Since such raw streams can be highly noisy and may not carry sufficient information for query processing, our system employs probabilistic models of the data generation process and stream-speed inference to transform raw data into a desired format with an uncertainty metric. The second component captures uncertainty as data propagates through query operators. To efficiently quantify result uncertainty of a query operator, we explore a variety of techniques based on probability and statisti...

Diao, Yanlei; Liu, Anna; Peng, Liping; Sutton, Charles; Tran, Thanh; Zink, Michael

2009-01-01T23:59:59.000Z

491

Direct Rendering of Deformable Volume Data Shiaofen Fang  

E-Print Network [OSTI]

Direct Rendering of Deformable Volume Data Shiaofen Fang Department of Computer and Information In this paper, we present a new deformable volume rendering algorithm. The volume deformation is modeled to directly render the deformed volume without going through the expensive volume construction process

Fang, Shiaofen

492

Dimensional SPC for low-volume production  

E-Print Network [OSTI]

. To make up for the weaknesses of SPC in low-volume production, a new method to test data independence, a new plot to describe the similarity between two charts, and two modified graphical tools are proposed. In low-volume production, it is frequently hard...

Chin, Chang-Ho

1999-01-01T23:59:59.000Z

493

Tourisme & Territoires / Tourism & Territories Volume 3 (2013)  

E-Print Network [OSTI]

Tourisme & Territoires / Tourism & Territories Volume 3 (2013) Achin & George-Marcelpoil Tourter de Grenoble, Unité de recherche Développement des territoires montagnards. #12;Tourisme & Territoires / Tourism & Territories Volume 3 (2013) Achin & George-Marcelpoil Tourter.com 68 ongtemps structurés autour

Paris-Sud XI, Université de

494

Programmatic methods for addressing contaminated volume uncertainties  

SciTech Connect (OSTI)

Accurate estimates of the volumes of contaminated soils or sediments are critical to effective program planning and to successfully designing and implementing remedial actions. Unfortunately, data available to support the pre-remedial design are often sparse and insufficient for accurately estimating contaminated soil volumes, resulting in significant uncertainty associated with these volume estimates. The uncertainty in the soil volume estimates significantly contributes to the uncertainty in the overall project cost estimates, especially since excavation and off-site disposal are the primary cost items in soil remedial action projects. The U.S. Army Corps of Engineers Buffalo District's experience has been that historical contaminated soil volume estimates developed under the Formerly Utilized Sites Remedial Action Program (FUSRAP) often underestimated the actual volume of subsurface contaminated soils requiring excavation during the course of a remedial activity. In response, the Buffalo District has adopted a variety of programmatic methods for addressing contaminated volume uncertainties. These include developing final status survey protocols prior to remedial design, explicitly estimating the uncertainty associated with volume estimates, investing in pre-design data collection to reduce volume uncertainties, and incorporating dynamic work strategies and real-time analytics in pre-design characterization and remediation activities. This paper describes some of these experiences in greater detail, drawing from the knowledge gained at Ashland 1, Ashland 2, Linde, and Rattlesnake Creek. In the case of Rattlesnake Creek, these approaches provided the Buffalo District with an accurate pre-design contaminated volume estimate and resulted in one of the first successful FUSRAP fixed-price remediation contracts for the Buffalo District. (authors)

Rieman, C.R.; Spector, H.L. [U.S. Army Corps of Engineers Buffalo District, Buffalo, NY (United States); Durham, L.A.; Johnson, R.L. [Argonne National Laboratory, Environmental Science Div., IL (United States)

2007-07-01T23:59:59.000Z

495

Assessment of inspectability of LMFBR designs. Volume 2. Appendixes. Final report  

SciTech Connect (OSTI)

This volume contains appendices on: LMFBR primary heat transport system, support systems for a pool-type reactor and guard tank, pool-type reactor and guard tank, NaK-cooled DDHRS and pool-type reactor deck structure and bimetallic weld of reactor tank.

Not Available

1981-09-01T23:59:59.000Z

496

Prediction Aggregation of Remote Traffic Microwave Sensors Speed and Volume Data  

E-Print Network [OSTI]

Prediction Aggregation of Remote Traffic Microwave Sensors Speed and Volume Data John R. Junger prediction is an importa