Sample records for volume refer primarily

  1. ILC Reference Design Report Volume 3 - Accelerator

    E-Print Network [OSTI]

    Phinney, Nan; Walker, Nicholas

    2007-01-01T23:59:59.000Z

    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.

  2. SAPHIRE 8 Volume 2 - Technical Reference

    SciTech Connect (OSTI)

    C. L. Smith; S. T. Wood; W. J. Galyean; J. A. Schroeder; M. B. Sattison

    2011-03-01T23:59:59.000Z

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of computer programs that were developed to create and analyze probabilistic risk assessment (PRAs). Herein information is provided on the principles used in the construction and operation of Version 8.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, Workspace algorithms, cut set "recovery," end state manipulation, and use of "compound events."

  3. ILC Reference Design Report Volume 1 - Executive Summary

    E-Print Network [OSTI]

    Brau, James; Walker, Nicholas

    2007-01-01T23:59:59.000Z

    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.

  4. ILC Reference Design Report Volume 1 - Executive Summary

    E-Print Network [OSTI]

    James Brau; Yasuhiro Okada; Nicholas Walker

    2007-12-12T23:59:59.000Z

    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.

  5. National Environmental Policy Act compliance guide. Volume II (reference book)

    SciTech Connect (OSTI)

    NONE

    1994-09-01T23:59:59.000Z

    This document (Volume II of the National Environmental Policy Act Compliance Guide) contains current copies of regulations and guidance from the Council on Environmental Quality, the Department of Energy, the Department of State, and the Environmental Protection Agency, related to compliance with the National Environmental Policy Act of 1969 (NEPA).

  6. Reference values for total blood volume and cardiac output in humans

    SciTech Connect (OSTI)

    Williams, L.R. [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences] [Indiana Univ., South Bend, IN (United States). Division of Liberal Arts and Sciences

    1994-09-01T23:59:59.000Z

    Much research has been devoted to measurement of total blood volume (TBV) and cardiac output (CO) in humans but not enough effort has been devoted to collection and reduction of results for the purpose of deriving typical or {open_quotes}reference{close_quotes} values. Identification of normal values for TBV and CO is needed not only for clinical evaluations but also for the development of biokinetic models for ultra-short-lived radionuclides used in nuclear medicine (Leggett and Williams 1989). The purpose of this report is to offer reference values for TBV and CO, along with estimates of the associated uncertainties that arise from intra- and inter-subject variation, errors in measurement techniques, and other sources. Reference values are derived for basal supine CO and TBV in reference adult humans, and differences associated with age, sex, body size, body position, exercise, and other circumstances are discussed.

  7. CULTURAL RATCHETING RESULTS PRIMARILY FROM SEMANTIC COMPRESSION

    E-Print Network [OSTI]

    Bryson, Joanna J.

    CULTURAL RATCHETING RESULTS PRIMARILY FROM SEMANTIC COMPRESSION JOANNA J. BRYSON Artificial Models that cultural ratcheting requires the communication of beliefs about #12;hypotheses. Clearly, cultural

  8. Home energy rating system building energy simulation test (HERS BESTEST). Volume 2, Tier 1 and Tier 2 tests reference results

    SciTech Connect (OSTI)

    Judkoff, R.; Neymark, J.

    1995-11-01T23:59:59.000Z

    The Home Energy Rating System (HERS) Building Energy Simulation Test (BESTEST) is a method for evaluating the credibility of software used by HERS to model energy use in buildings. The method provides the technical foundation for ''certification of the technical accuracy of building energy analysis tools used to determine energy efficiency ratings,'' as called for in the Energy Policy Act of 1992 (Title I, Subtitle A, Section 102, Title II, Part 6, Section 271). Certification is accomplished with a uniform set of test cases that Facilitate the comparison of a software tool with several of the best public-domain, state-of-the-art building energy simulation programs available in the United States. The HERS BESTEST work is divided into two volumes. Volume 1 contains the test case specifications and is a user's manual for anyone wishing to test a computer program. Volume 2 contains the reference results and suggestions for accrediting agencies on how to use and interpret the results.

  9. Proposed Site Treatment Plan (PSTP). Volumes 1 and 2 and Reference Document

    SciTech Connect (OSTI)

    Helmich, E.; Noller, D.K.; Wierzbicki, K.S.; Bailey, L.L.

    1994-12-22T23:59:59.000Z

    The Compliance Plan Volume provides overall schedules with target dates for achieving compliance with the land disposal restrictions (LDR) and contains procedures to establish milestones to be enforced under the Order. Information regarding the technical evaluation of treatment options for SRS mixed wastes is contained in the Background Volume and is provided for informational purposes only.

  10. Technology, safety and costs of decommissioning a reference boiling water reactor power station. Appendices. Volume 2

    SciTech Connect (OSTI)

    Oak, H.D.; Holter, G.M.; Kennedy, W.E. Jr.; Konzek, G.J.

    1980-06-01T23:59:59.000Z

    Appendices are presented concerning the evaluations of decommissioning financing alternatives; reference site description; reference BWR facility description; radiation dose rate and concrete surface contamination data; radionuclide inventories; public radiation dose models and calculated maximum annual doses; decommissioning methods; generic decommissioning information; immediate dismantlement details; passive safe storage, continuing care, and deferred dismantlement details; entombment details; demolition and site restoration details; cost estimating bases; public radiological safety assessment details; and details of alternate study bases.

  11. Final safety analysis report for the Galileo Mission: Volume 1, Reference design document

    SciTech Connect (OSTI)

    Not Available

    1988-05-01T23:59:59.000Z

    The Galileo mission uses nuclear power sources called Radioisotope Thermoelectric Generators (RTGs) to provide the spacecraft's primary electrical power. Because these generators contain nuclear material, a Safety Analysis Report (SAR) is required. A preliminary SAR and an updated SAR were previously issued that provided an evolving status report on the safety analysis. As a result of the Challenger accident, the launch dates for both Galileo and Ulysses missions were later rescheduled for November 1989 and October 1990, respectively. The decision was made by agreement between the DOE and the NASA to have a revised safety evaluation and report (FSAR) prepared on the basis of these revised vehicle accidents and environments. The results of this latest revised safety evaluation are presented in this document (Galileo FSAR). Volume I, this document, provides the background design information required to understand the analyses presented in Volumes II and III. It contains descriptions of the RTGs, the Galileo spacecraft, the Space Shuttle, the Inertial Upper Stage (IUS), the trajectory and flight characteristics including flight contingency modes, and the launch site. There are two appendices in Volume I which provide detailed material properties for the RTG.

  12. Special topics reports for the reference tandem mirror fusion breeder. Volume 2. Reactor safety assessment

    SciTech Connect (OSTI)

    Maya, I.; Hoot, C.G.; Wong, C.P.C.; Schultz, K.R.; Garner, J.K.; Bradbury, S.J.; Steele, W.G.; Berwald, D.H.

    1984-09-01T23:59:59.000Z

    The safety features of the reference fission suppressed fusion breeder reactor are presented. These include redundancy and overcapacity in primary coolant system components to minimize failure probability, an improved valve location logic to provide for failed component isolation, and double-walled coolant piping and steel guard vessel protection to further limit the extent of any leak. In addition to the primary coolant and decay heat removal system, reactor safety systems also include an independent shield cooling system, the module safety/fuel transfer coolant system, an auxiliary first wall cooling system, a psssive dump tank cooling system based on the use of heat pipes, and several lithium fire suppression systems. Safety system specifications are justified based on the results of thermal analysis, event tree construction, consequence calculations, and risk analysis. The result is a reactor design concept with an acceptably low probability of a major radioactivity release. Dose consequences of maximum credible accidents appear to be below 10CFR100 regulatory limits.

  13. Technology, safety and costs of decommissioning a reference low-level waste burial ground. Volume 2. Appendices. Technical report

    SciTech Connect (OSTI)

    Murphy, E.S.; Holter, G.M.

    1980-06-01T23:59:59.000Z

    Contents: Reference site details; Waste inventory details; Radiation dose methodology; Environmental surveillance and records maintenance details; Payments needed to finance decommissioning; Site/waste stabilization decommissioning activity details; Waste relocation decommissioning activity details; Cost assessment details; Radiological safety details.

  14. Technology, safety and costs of decommissioning a reference boiling water reactor power station. Volume 2. Appendices. Technical report, September 1977-October 1979

    SciTech Connect (OSTI)

    Oak, H.D.; Holter, G.M.; Kennedy, W.E. Jr.; Konzek, G.J.

    1980-06-01T23:59:59.000Z

    Technology, safety and cost information is given for the conceptual decommissioning of a large (1100MWe) boiling water reactor (BWR) power station. Three approaches to decommissioning, immediate dismantlement, safe storage with deferred dismantlement and entombment, were studied to obtain comparisons between costs, occupational radiation doses, potential dose to the public and other safety impacts. It also shows the sensitivity of decommissioning safety and costs to the power rating of a BWR in the range of 200 to 1100 MWE. This volume contains the appendices.

  15. Poroelastic references

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Christina Morency

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  16. Poroelastic references

    SciTech Connect (OSTI)

    Christina Morency

    2014-12-12T23:59:59.000Z

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  17. Reference Material

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection RadiationRecord-SettingHead ofReference-Documents Sign In

  18. Reference Documents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection RadiationRecord-SettingHead ofReference-Documents Sign In About |

  19. Participant Support Costs Participant support is often provided for awards made primarily for organized training,

    E-Print Network [OSTI]

    Salama, Khaled

    Participant Support Costs Participant support is often provided for awards made primarily costs cannot be used for any other purpose and thus cannot be rebudgeted into other areas without sponsor approval. The purpose of these funds is to support the costs of individual participants

  20. Weather encapsulates the state of the atmosphere, primarily involving the component which affects

    E-Print Network [OSTI]

    Allan, Richard P.

    1 #12;2 Weather encapsulates the state of the atmosphere, primarily involving the component which and Telegraph readers tend to use oF #12;5 The human body has an energy balance just like the Earth (solar range in larger on still, clear days, when solar heating is strong at the surface and is not offset

  1. The use and tenure of land in Oklahoma held primarily for its mineral potential

    E-Print Network [OSTI]

    Parcher, L. A.

    1955-01-01T23:59:59.000Z

    primarily for its mineral value was virtually the same in all counties visited in the Cross Timbers Area, an area of generally poor-quality land. The point was made frequently that speculative owners probably were able to buy the fee simple title almost... interest was non? mineral. In the cases found, such owners generally held tracts which local people believed were accumulated originally for mineral speculation* Another procedure might have been to choose tracts at random over the entire county or area...

  2. Hawaii demand-side management resource assessment. Final report, Reference Volume 3 -- Residential and commercial sector DSM analyses: Detailed results from the DBEDT DSM assessment model; Part 1, Technical potential

    SciTech Connect (OSTI)

    NONE

    1995-04-01T23:59:59.000Z

    The Hawaii Demand-Side Management Resource Assessment was the fourth of seven projects in the Hawaii Energy Strategy (HES) program. HES was designed by the Department of Business, Economic Development, and Tourism (DBEDT) to produce an integrated energy strategy for the State of Hawaii. The purpose of Project 4 was to develop a comprehensive assessment of Hawaii`s demand-side management (DSM) resources. To meet this objective, the project was divided into two phases. The first phase included development of a DSM technology database and the identification of Hawaii commercial building characteristics through on-site audits. These Phase 1 products were then used in Phase 2 to identify expected energy impacts from DSM measures in typical residential and commercial buildings in Hawaii. The building energy simulation model DOE-2.1E was utilized to identify the DSM energy impacts. More detailed information on the typical buildings and the DOE-2.1E modeling effort is available in Reference Volume 1, ``Building Prototype Analysis``. In addition to the DOE-2.1E analysis, estimates of residential and commercial sector gas and electric DSM potential for the four counties of Honolulu, Hawaii, Maui, and Kauai through 2014 were forecasted by the new DBEDT DSM Assessment Model. Results from DBEDTs energy forecasting model, ENERGY 2020, were linked with results from DOE-2.1E building energy simulation runs and estimates of DSM measure impacts, costs, lifetime, and anticipated market penetration rates in the DBEDT DSM Model. Through its algorithms, estimates of DSM potential for each forecast year were developed. Using the load shape information from the DOE-2.1E simulation runs, estimates of electric peak demand impacts were developed. Numerous tables and figures illustrating the technical potential for demand-side management are included.

  3. Using This Bulletin This bulletin is intended primarily to provide users with Penn State academic

    E-Print Network [OSTI]

    Yener, Aylin

    of the home page. In the bulletin, the word Program refers to an academic program (majors, minors, and special for specifics with the site search engines. The University-wide General Education requirements are explained another Web browser. The site follows conventional navigation practices, so once in secondary pages, users

  4. Using This Bulletin This bulletin is intended primarily to provide users with Penn State academic information.

    E-Print Network [OSTI]

    Yener, Aylin

    of the home page. In the bulletin, the word Program refers to an academic program (majors, minors, and special for specifics with the site search engines. The University-wide General Education requirements are explained another Web browser. The site follows conventional navigation practices, so once in secondary pages, users

  5. Identification of a novel CoA synthase isoform, which is primarily expressed in Brain

    SciTech Connect (OSTI)

    Nemazanyy, Ivan [Department of Structure and Function of Nucleic Acids, Institute of Molecular Biology and Genetics, 150 Zabolotnogo St, Kyiv 03680 (Ukraine)]. E-mail: nemazanyy@imbg.org.ua; Panasyuk, Ganna [Department of Structure and Function of Nucleic Acids, Institute of Molecular Biology and Genetics, 150 Zabolotnogo St, Kyiv 03680 (Ukraine); Breus, Oksana [Department of Structure and Function of Nucleic Acids, Institute of Molecular Biology and Genetics, 150 Zabolotnogo St, Kyiv 03680 (Ukraine); Zhyvoloup, Alexander [Department of Structure and Function of Nucleic Acids, Institute of Molecular Biology and Genetics, 150 Zabolotnogo St, Kyiv 03680 (Ukraine); Filonenko, Valeriy [Department of Structure and Function of Nucleic Acids, Institute of Molecular Biology and Genetics, 150 Zabolotnogo St, Kyiv 03680 (Ukraine); Gout, Ivan T. [Department of Structure and Function of Nucleic Acids, Institute of Molecular Biology and Genetics, 150 Zabolotnogo St, Kyiv 03680 (Ukraine) and Department of Biochemistry and Molecular Biology, Royal Free and University College Medical School, Gower Street, London WC1E 6BT (United Kingdom)]. E-mail: i.gout@ucl.ac.uk

    2006-03-24T23:59:59.000Z

    CoA and its derivatives Acetyl-CoA and Acyl-CoA are important players in cellular metabolism and signal transduction. CoA synthase is a bifunctional enzyme which mediates the final stages of CoA biosynthesis. In previous studies, we have reported molecular cloning, biochemical characterization, and subcellular localization of CoA synthase (CoASy). Here, we describe the existence of a novel CoA synthase isoform, which is the product of alternative splicing and possesses a 29aa extension at the N-terminus. We termed it CoASy {beta} and originally identified CoA synthase, CoASy {alpha}. The transcript specific for CoASy {beta} was identified by electronic screening and by RT-PCR analysis of various rat tissues. The existence of this novel isoform was further confirmed by immunoblot analysis with antibodies directed to the N-terminal peptide of CoASy {beta}. In contrast to CoASy {alpha}, which shows ubiquitous expression, CoASy {beta} is primarily expressed in Brain. Using confocal microscopy, we demonstrated that both isoforms are localized on mitochondria. The N-terminal extension does not affect the activity of CoA synthase, but possesses a proline-rich sequence which can bring the enzyme into complexes with signalling proteins containing SH3 or WW domains. The role of this novel isoform in CoA biosynthesis, especially in Brain, requires further elucidation.

  6. Model Reference Adaptive Control Framework for Real Time Traffic

    E-Print Network [OSTI]

    Minnesota, University of

    Adaptive Control #12;12 Prescriptive Dynamic Traffic Assignment A Prediction Model and the Reference ModelModel Reference Adaptive Control Framework for Real Time Traffic Management Under Emergency Movement Volume Adaptive Controller Model Reference Adaptive Control (MRAC) Assumptions Super Zone Concept

  7. Previous Up Next Article From References: 0

    E-Print Network [OSTI]

    Stachó, László

    Previous Up Next Article Citations From References: 0 From Reviews: 0 MR561879 (81d:62015) 62E20 for the volume of the intersection of an n-dimensional simplex and an n-dimensional ball is also given. {For

  8. References to Astrophysics Papers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of the Royal Astronomical Society, 2014, Volume 445, Issue 4, p.4435-4442, Three Einstein rings: explicit solution and numerical simulation Alatalo, K.; Appleton, P. N.;...

  9. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, J.W.

    1994-05-31T23:59:59.000Z

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

  10. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, R.; Kotter, D.

    1994-04-26T23:59:59.000Z

    An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

  11. Application Protocol Reference Architecture Application Protocol Reference Architecture

    E-Print Network [OSTI]

    van Sinderen, Marten

    Application Protocol Reference Architecture 165 Chapter 7 Application Protocol Reference Architecture This chapter proposes an alternative reference architecture for application protocols. The proposed reference architecture consists of the set of possible architectures for application protocols

  12. Value of Information References

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Morency, Christina

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  13. Value of Information References

    SciTech Connect (OSTI)

    Morency, Christina

    2014-12-12T23:59:59.000Z

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  14. Precision displacement reference system

    DOE Patents [OSTI]

    Bieg, Lothar F. (Albuquerque, NM); Dubois, Robert R. (Albuquerque, NM); Strother, Jerry D. (Edgewood, NM)

    2000-02-22T23:59:59.000Z

    A precision displacement reference system is described, which enables real time accountability over the applied displacement feedback system to precision machine tools, positioning mechanisms, motion devices, and related operations. As independent measurements of tool location is taken by a displacement feedback system, a rotating reference disk compares feedback counts with performed motion. These measurements are compared to characterize and analyze real time mechanical and control performance during operation.

  15. Membrane reference electrode

    DOE Patents [OSTI]

    Redey, L.; Bloom, I.D.

    1988-01-21T23:59:59.000Z

    A reference electrode utilizes a small thin, flat membrane of a highly conductive glass placed on a small diameter insulator tube having a reference material inside in contact with an internal voltage lead. When the sensor is placed in a non-aqueous ionic electrolytic solution, the concentration difference across the glass membrane generates a low voltage signal in precise relationship to the concentration of the species to be measured, with high spatial resolution. 2 figs.

  16. Viability Assessment Volume 5

    SciTech Connect (OSTI)

    DOE,

    1998-12-01T23:59:59.000Z

    This volume presents a management summary of the cost estimate to complete the design, and to license, construct, operate, monitor, close, and decommission a Monitored Geologic Repository at Yucca Mountain in Nevada. This volume summarizes the scope, estimating methodologies, and assumptions used in development of the Monitored Geologic Repository-VA cost estimate. It identifies the key features necessary to understand the summary costs presented herein. This cost summary derives from a larger body of documented cost analysis. Volume 5 is organized to reflect this structured approach to cost estimation and contains the following sections: Section 1, Cost Elements. This section briefly defines the components of each major repository cost element. Section 2, Project Phases. This section presents the definition, as used in the estimate, of five project phases (Licensing, Pre-emplacement Construction, Emplacement Operations, Monitoring, and Closure and Decommissioning) and the schedule dates for each phase. It also contains major milestone dates and a bar chart schedule. Section 3, Major Assumptions. This section identifies key high-level assumptions for the cost estimate basis. Additional detailed assumptions are included in the appendices. Section 4, Integrated Cost Summary. This section presents a high-level roll-up of the VA costs resulting from the estimating work. The tables and figures contained in this section were compiled from the more detailed cost estimates in the appendices. Section 5, References. This section identifies the references that support this cost volume. Appendices. For each major repository cost element, Appendices B-F [B, C, D, E, F] presents additional information on the scope of cost elements, identifies methodologies used to develop the cost estimates, lists underlying cost assumptions, and tabulates summary results. Appendix A contains a glossary to assist the reader in understanding the terminology in Volume 5. Appendix G presents costs associated with three VA design options, as described in Volume 2. These costs are provided for information and are not compiled into the integrated cost summary.

  17. Multifunctional reference electrode

    DOE Patents [OSTI]

    Redey, L.; Vissers, D.R.

    1981-12-30T23:59:59.000Z

    A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell are described. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

  18. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, D.R.

    1988-08-16T23:59:59.000Z

    A stable reference electrode is described for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na[sub 3]AlF[sub 6], wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution. 1 fig.

  19. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, Donald R. (Belmont, MA)

    1988-01-01T23:59:59.000Z

    A stable reference electrode for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na.sub.3 AlF.sub.6, wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution.

  20. Multifunctional reference electrode

    DOE Patents [OSTI]

    Redey, Laszlo (Lisle, IL); Vissers, Donald R. (Naperville, IL)

    1983-01-01T23:59:59.000Z

    A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

  1. Grant Reference Lead / Sole

    E-Print Network [OSTI]

    Rank Overall Score Grant Reference Lead / Sole Grant Grant Holder Research Organisation Project of Birmingham Controls on Soil Carbon Export revealed by Novel Tracers on multiple timescales (SCENT) Standard Grant DEC12 8 8 NE/K011871/1 N Melanie Leng NERC British Geological Survey A 500,000-year environmental

  2. HAZARDOUS WASTE MANAGEMENT REFERENCE

    E-Print Network [OSTI]

    Faraon, Andrei

    Principal Investigators 7 Laboratory Personnel 8 EH&S Personnel 8 HAZARDOUS WASTE ACCUMULATION AREAS 9 Satellite Accumulation Area 9 Waste Accumulation Facility 10 HAZARDOUS WASTE CONTAINER MANAGEMENT LabelingHAZARDOUS WASTE MANAGEMENT REFERENCE GUIDE Prepared by Environment, Health and Safety Office

  3. CONCRETE PAVEMENT Reference Manual

    E-Print Network [OSTI]

    CONCRETE PAVEMENT Reference Manual Prepared for Federal Highway Administration Office of Pavement by National Concrete Pavement Technology Center at Iowa State University 2711 South Loop Drive, Suite 4700 No. 3. Recipient's Catalog No. 4. Title and Subtitle 5. Report Date February 2008 Concrete Pavement

  4. MSL ENTERANCE REFERENCE AREA

    E-Print Network [OSTI]

    Aalberts, Daniel P.

    MSL ENTERANCE LOBBY ELEV STAIRS SSL-019 REFERENCE AREA SSL-021 GROUP STUDY SSL-018 STUDY ROOM SSL-029 SSL-020 COPY ROOM SSL-022 GROUP STUDY SSL-026 STACKS SSL-023 GROUP STUDY SSL-024 GROUP STUDY SSL TBL-014 TBL-014A STAIRS SSL-007 GIS/ WORKROOM SSL-011 SSL-008 SSL-009 SSL-010 SSL-014 SSL-017 STAIRS

  5. Cisco Reference Configurations for

    E-Print Network [OSTI]

    Chaudhuri, Surajit

    ............................................................................................. 10 EMC VNX5500 Storage Layout.0 with EMC VNX5500 Series Storage Systems White Paper November 2012 © 2012 Cisco and/or its affiliates. AllCisco Reference Configurations for Microsoft SQL Server 2012 Fast Track Data Warehouse 4.0 with EMC

  6. Viability Assessment Volume 4

    SciTech Connect (OSTI)

    DOE

    1998-12-01T23:59:59.000Z

    Volume 4 provides the DOE plan and cost estimate for the remaining work necessary to proceed from completing this VA to submitting an LA to NRC. This work includes preparing an EIS and evaluating the suitability of the site. Both items are necessary components of the documentation required to support a decision in 2001 by the Secretary of Energy on whether or not to recommend that the President approve the site for development as a repository. If the President recommends the site to Congress and the site designation becomes effective, then DOE will submit the LA to NRC in 2002 for authorization to construct the repository. The work described in Volume 4 constitutes the last step in the characterization of the Yucca Mountain site and the design and evaluation of the performance of a repository system in the geologic setting of this site. The plans in this volume for the next 4 years' work are based on the results of the previous 15 years' work, as reported in Volumes 1, 2, and 3 of this VA. Volume 1 summarizes what DOE has learned to date about the Yucca Mountain site. Volume 2 describes the current, reference repository design, several design options that might enhance the performance of the reference design, and several alternative designs that represent substantial departures from the reference design. Volume 2 also summarizes the results of tests of candidate materials for waste packages and for support of the tunnels into which waste would be emplaced. Volume 3 provides the results of the latest performance assessments undertaken to evaluate the performance of the design in the geologic setting of Yucca Mountain. The results described in Volumes 1, 2, and 3 provide the basis for identifying and prioritizing the work described in this volume. DOE believes that the planned work, together with the results of previous work, will be sufficient to support a site suitability evaluation for site recommendation and, if the site is recommended and designated, a defensible LA. Volume 4 is divided into seven sections. Section 2 presents a rationale and summary for the technical work to be done to develop the preclosure and postclosure safety cases that will support the compliance evaluations required for the evaluation of site suitability and for licensing. Section 2 also describes other necessary technical work, including that needed to support design decisions and development of the necessary design information. Section 3 presents a more detailed description of the technical work required to address the issues identified in Section 2. Section 3 also describes activities that will continue after submittal of the site recommendation and the LA. Examples include the drift scale heater test in the Exploratory Studies Facility (Section 3.1.4.3) and long-term waste package corrosion testing (Section 3.2.2.9). Section 4 discusses the statutory and regulatory framework for site recommendation and submittal of an LA, and describes the activities and documentation that must be completed to achieve these milestones, including the development of an EIS. Section 5 describes the numerous activities required to support program milestones, including support for completing the testing program, continuing tests as part of the performance confirmation program, and managing information and records to support regulatory and legal review. Sections 6 and 7 provide cost and schedule information for the activities planned.

  7. OSH technical reference manual

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    In an evaluation of the Department of Energy (DOE) Occupational Safety and Health programs for government-owned contractor-operated (GOCO) activities, the Department of Labor`s Occupational Safety and Health Administration (OSHA) recommended a technical information exchange program. The intent was to share written safety and health programs, plans, training manuals, and materials within the entire DOE community. The OSH Technical Reference (OTR) helps support the secretary`s response to the OSHA finding by providing a one-stop resource and referral for technical information that relates to safe operations and practice. It also serves as a technical information exchange tool to reference DOE-wide materials pertinent to specific safety topics and, with some modification, as a training aid. The OTR bridges the gap between general safety documents and very specific requirements documents. It is tailored to the DOE community and incorporates DOE field experience.

  8. Reference Undulator Measurement Results

    SciTech Connect (OSTI)

    Wolf, Zachary; Levashov, Yurii; /SLAC; ,

    2011-08-18T23:59:59.000Z

    The LCLS reference undulator has been measured 22 times during the course of undulator tuning. These measurements provide estimates of various statistical errors. This note gives a summary of the reference undulator measurements and it provides estimates of the undulator tuning errors. We measured the reference undulator many times during the tuning of the LCLS undulators. These data sets give estimates of the random errors in the tuned undulators. The measured trajectories in the reference undulator are stable and straight to within {+-}2 {micro}m. Changes in the phase errors are less than {+-}2 deg between data sets. The phase advance in the cell varies by less than {+-}2 deg between data sets. The rms variation between data sets of the first integral of B{sub x} is 9.98 {micro}Tm, and the rms variation of the second integral of B{sub x} is 17.4 {micro}Tm{sup 2}. The rms variation of the first integral of B{sub y} is 6.65 {micro}Tm, and the rms variation of the second integral of B{sub y} is 12.3 {micro}Tm{sup 2}. The rms variation of the x-position of the fiducialized beam axis is 35 {micro}m in the final production run This corresponds to an rms uncertainty in the K value of {Delta}K/K = 2.7 x 10{sup -5}. The rms variation of the y-position of the fiducialized beam axis is 4 {micro}m in the final production run.

  9. STEP Intern Reference Check Sheet

    Broader source: Energy.gov [DOE]

    STEP Intern Reference Check Sheet, from the Tool Kit Framework: Small Town University Energy Program (STEP).

  10. WECC Variable Generation Planning Reference Book: Appendices

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-13T23:59:59.000Z

    The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

  11. Volume 43, Number 2, April 2002 F 313 References Cited

    E-Print Network [OSTI]

    , Pete Richerson, Monique Borgerhoff Mulder, and anony- mous referees for their very useful comments to call it evolutionary cultural anthropology (Hewlett and Lamb n.d.) because the major theoretical explain this diversity. Discussions of race and culture were major components of early an- thropology

  12. Transaction-Based Building Controls Framework, Volume 1: Reference Guide

    SciTech Connect (OSTI)

    Somasundaram, Sriram; Pratt, Robert G.; Akyol, Bora A.; Fernandez, Nicholas; Foster, Nikolas AF; Katipamula, Srinivas; Mayhorn, Ebony T.; Somani, Abhishek; Steckley, Andrew C.; Taylor, Zachary T.

    2014-04-28T23:59:59.000Z

    This document proposes a framework concept to achieve the objectives of raising buildings’ efficiency and energy savings potential benefitting building owners and operators. We call it a transaction-based framework, wherein mutually-beneficial and cost-effective market-based transactions can be enabled between multiple players across different domains. Transaction-based building controls are one part of the transactional energy framework. While these controls realize benefits by enabling automatic, market-based intra-building efficiency optimizations, the transactional energy framework provides similar benefits using the same market -based structure, yet on a larger scale and beyond just buildings, to the society at large.

  13. 1993 Solid Waste Reference Forecast Summary

    SciTech Connect (OSTI)

    Valero, O.J.; Blackburn, C.L. [Westinghouse Hanford Co., Richland, WA (United States); Kaae, P.S.; Armacost, L.L.; Garrett, S.M.K. [Pacific Northwest Lab., Richland, WA (United States)

    1993-08-01T23:59:59.000Z

    This report, which updates WHC-EP-0567, 1992 Solid Waste Reference Forecast Summary, (WHC 1992) forecasts the volumes of solid wastes to be generated or received at the US Department of Energy Hanford Site during the 30-year period from FY 1993 through FY 2022. The data used in this document were collected from Westinghouse Hanford Company forecasts as well as from surveys of waste generators at other US Department of Energy sites who are now shipping or plan to ship solid wastes to the Hanford Site for disposal. These wastes include low-level and low-level mixed waste, transuranic and transuranic mixed waste, and nonradioactive hazardous waste.

  14. Viability Assessment Volume 2

    SciTech Connect (OSTI)

    DOE

    1998-12-01T23:59:59.000Z

    This volume describes the major design features of the Monitored Geologic Repository. This document is not intended to provide an exhaustive, detailed description of the repository design. Rather, this document summarizes the major systems and primary elements of the design that are radiologically significant, and references the specific technical documents and design analyses wherein the details can be found. Not all portions of the design are at the same level of completeness. Highest priority has been given to assigning resources to advance the design of the Monitored Geologic Repository features that are important to radiological safety and/or waste isolation and for which there is no NRC licensing precedent. Those features that are important to radiological safety and/or waste isolation, but for which there is an NRC precedent, receive second priority. Systems and features that have no impact on radiological safety or waste isolation receive the lowest priority. This prioritization process, referred to as binning, is discussed in more detail in Section 2.3. Not every subject discussed in this volume is given equal treatment with regard to the level of detail provided. For example, less detail is provided for the surface facility design than for the subsurface and waste package designs. This different level of detail is intentional. Greater detail is provided for those functions, structures, systems, and components that play key roles with regard to protecting radiological health and safety and that are not common to existing nuclear facilities already licensed by NRC. A number of radiological subjects are not addressed in the VA, (e.g., environmental qualification of equipment). Environmental qualification of equipment and other radiological safety considerations will be addressed in the LA. Non-radiological safety considerations such as silica dust control and other occupational safety considerations are considered equally important but are not addressed in th is volume of the VA (see Volume 1, Section 2.2.1.2, subsection on Health Related Mineral Issues).

  15. Optomechanical reference accelerometer

    E-Print Network [OSTI]

    Gerberding, Oliver; Melcher, John; Pratt, Jon; Taylor, Jacob

    2015-01-01T23:59:59.000Z

    We present an optomechanical accelerometer with high dynamic range, high bandwidth and read-out noise levels below 8 {\\mu}g/$\\sqrt{\\mathrm{Hz}}$. The straightforward assembly and low cost of our device make it a prime candidate for on-site reference calibrations and autonomous navigation. We present experimental data taken with a vacuum sealed, portable prototype and deduce the achieved bias stability and scale factor accuracy. Additionally, we present a comprehensive model of the device physics that we use to analyze the fundamental noise sources and accuracy limitations of such devices.

  16. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40CoalLease(Billion CubicPotentialNov-14 Dec-14 Jan-1538,469Appendix E4 Reference

  17. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40CoalLease(Billion CubicPotentialNov-14 Dec-14 Jan-1538,469Appendix E4 Reference4

  18. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40CoalLease(Billion CubicPotentialNov-14 Dec-14 Jan-1538,469Appendix E4 Reference46

  19. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40CoalLease(Billion CubicPotentialNov-14 Dec-14 Jan-1538,469Appendix E44 Reference

  20. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1 Year-2CubiccurrentFor2 Reference

  1. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1 Year-2CubiccurrentFor2 Reference4

  2. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1 Year-2CubiccurrentFor2 Reference46

  3. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1 Year-2CubiccurrentFor2 Reference464

  4. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1 Year-2CubiccurrentFor24 Reference

  5. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1 Year-2CubiccurrentFor24 Reference6

  6. Appendix A: Reference case

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at CommercialDecade Year-0 Year-1 Year-2CubiccurrentFor24 Reference68

  7. REFERENCES Baines, W. D.

    Office of Scientific and Technical Information (OSTI)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilAElectronicCurvesSpeedingScientificof ScientificQ LA-UR- " "REFERENCES

  8. References to Astrophysics Papers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Scienceand Requirements Recently Approved JustificationBio-Inspired SolarReferences to

  9. Antares Reference Telescope System

    SciTech Connect (OSTI)

    Viswanathan, V.K.; Kaprelian, E.; Swann, T.; Parker, J.; Wolfe, P.; Woodfin, G.; Knight, D.

    1983-01-01T23:59:59.000Z

    Antares is a 24-beam, 40-TW carbon-dioxide laser-fusion system currently nearing completion at the Los Alamos National Laboratory. The 24 beams will be focused onto a tiny target (typically 300 to 1000 ..mu..m in diameter) located approximately at the center of a 7.3-m-diameter by 9.3-m-long vacuum (10/sup -6/ torr) chamber. The design goal is to position the targets to within 10 ..mu..m of a selected nominal position, which may be anywhere within a fixed spherical region 1 cm in diameter. The Antares Reference Telescope System is intended to help achieve this goal for alignment and viewing of the various targets used in the laser system. The Antares Reference Telescope System consists of two similar electro-optical systems positioned in a near orthogonal manner in the target chamber area of the laser. Each of these consists of four subsystems: (1) a fixed 9X optical imaging subsystem which produces an image of the target at the vidicon; (2) a reticle projection subsystem which superimposes an image of the reticle pattern at the vidicon; (3) an adjustable front-lighting subsystem which illuminates the target; and (4) an adjustable back-lighting subsystem which also can be used to illuminate the target. The various optical, mechanical, and vidicon design considerations and trade-offs are discussed. The final system chosen (which is being built) and its current status are described in detail.

  10. Coal data: A reference

    SciTech Connect (OSTI)

    Not Available

    1995-02-01T23:59:59.000Z

    This report, Coal Data: A Reference, summarizes basic information on the mining and use of coal, an important source of energy in the US. This report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section ``Supplemental Figures and Tables`` contains statistics, graphs, maps, and other illustrations that show trends, patterns, geographic locations, and similar coal-related information. The section ``Coal Terminology and Related Information`` provides additional information about terms mentioned in the text and introduces some new terms. The last edition of Coal Data: A Reference was published in 1991. The present edition contains updated data as well as expanded reviews and additional information. Added to the text are discussions of coal quality, coal prices, unions, and strikes. The appendix has been expanded to provide statistics on a variety of additional topics, such as: trends in coal production and royalties from Federal and Indian coal leases, hours worked and earnings for coal mine employment, railroad coal shipments and revenues, waterborne coal traffic, coal export loading terminals, utility coal combustion byproducts, and trace elements in coal. The information in this report has been gleaned mainly from the sources in the bibliography. The reader interested in going beyond the scope of this report should consult these sources. The statistics are largely from reports published by the Energy Information Administration.

  11. CH 6 REFERENCES.DOC 6-1 6 References

    E-Print Network [OSTI]

    REFERENCES.DOC Allan, S., A. R. Buckley, and J. E. Meacham. 2001. Atlas of Oregon. Second Edition. William J

  12. Nuclear Science References Database

    E-Print Network [OSTI]

    B. Pritychenko; E. B?ták; B. Singh; J. Totans

    2014-07-08T23:59:59.000Z

    The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center http://www.nndc.bnl.gov/nsr and the International Atomic Energy Agency http://www-nds.iaea.org/nsr.

  13. Long life reference electrode

    DOE Patents [OSTI]

    Yonco, R.M.; Nagy, Z.

    1987-07-30T23:59:59.000Z

    An external, reference electrode is provided for long term use with a high temperature, high pressure system. The electrode is arranged in a vertical, electrically insulative tube with an upper portion serving as an electrolyte reservoir and a lower portion in electrolytic communication with the system to be monitored. The lower end portion includes a flow restriction such as a porous plug to limit the electrolyte release into the system. A piston equalized to the system pressure is fitted into the upper portion of the tube to impart a small incremental pressure to the electrolyte. The piston is selected of suitable size and weight to cause only a slight flow of electrolyte through the porous plug into the high pressure system. This prevents contamination of the electrolyte but is of such small flow rate that operating intervals of a month or more can be achieved. 2 figs.

  14. Landscapes as references for design

    E-Print Network [OSTI]

    Batchelor, James P

    1981-01-01T23:59:59.000Z

    This is a study of the ways in which the forms in landscapes - natural terrain adapted and inhabited - can serve as references in architectural design. As references for design, landscapes provide a richness of responses ...

  15. Budget Reconciliation Procedures Reference Guide

    E-Print Network [OSTI]

    Shull, Kenneth R.

    Budget Reconciliation Procedures Reference Guide eDev Course Number FMS723 Subject Area Budget Northwestern University #12;Reference Guide Budget Reconciliation Table of Contents Helpful Contacts....................................................................................... 14 723QuickRefGuidev1.4 2 of 14 #12;Reference Guide Budget Reconciliation Helpful Contacts Below

  16. E-Print Network 3.0 - area washington volume Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    perfect model59 studies with the Community Climate System Model version 4... -Arctic sea ice area or volume (henceforth refered to as just area93 or volume) and the indexes j...

  17. COSY INFINITY reference manual

    SciTech Connect (OSTI)

    Berz, M.

    1990-07-01T23:59:59.000Z

    This is a reference manual for the arbitrary order particle optics and beam dynamics code COSY INFINITY. It is current as of June 28, 1990. COSY INFINITY is a code to study and design particle optical systems, including beamlines, spectrometers, and particle accelerators. At its core it is using differential algebraic (DA) methods, which allow a very systematic and simple calculation of high order effects. At the same time, it allows the computation of dependences on system parameters, which is often interesting in its own right and can also be used for fitting. COSY INFINITY has a full structured object oriented language environment. This provides a simple interface for the casual user. At the same time, it offers the demanding user a very flexible and powerful tool for the study and design of systems, and more generally, the utilization of DA methods. The power and generality of the environment is perhaps best demonstrated by the fact that the physics routines of COSY INFINITY are written in its own input language and are very compact. The approach also considerably facilitates the implementation of new features because they are incorporated with the same commands that are used for design and study. 26 refs.

  18. Sensor Characteristics Reference Guide

    SciTech Connect (OSTI)

    Cree, Johnathan V.; Dansu, A.; Fuhr, P.; Lanzisera, Steven M.; McIntyre, T.; Muehleisen, Ralph T.; Starke, M.; Banerjee, Pranab; Kuruganti, T.; Castello, C.

    2013-04-01T23:59:59.000Z

    The Buildings Technologies Office (BTO), within the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), is initiating a new program in Sensor and Controls. The vision of this program is: • Buildings operating automatically and continuously at peak energy efficiency over their lifetimes and interoperating effectively with the electric power grid. • Buildings that are self-configuring, self-commissioning, self-learning, self-diagnosing, self-healing, and self-transacting to enable continuous peak performance. • Lower overall building operating costs and higher asset valuation. The overarching goal is to capture 30% energy savings by enhanced management of energy consuming assets and systems through development of cost-effective sensors and controls. One step in achieving this vision is the publication of this Sensor Characteristics Reference Guide. The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information

  19. Phase 1 remedial investigation report for 200-BP-1 operable unit. Volume 2

    SciTech Connect (OSTI)

    Not Available

    1993-09-01T23:59:59.000Z

    Volume two contains appendices for the following: crib soil sample reference table; crib soil analytical data; and crib soil quality control data.

  20. Optical probe with reference fiber

    DOE Patents [OSTI]

    Da Silva, Luiz B. (Danville, CA); Chase, Charles L. (Dublin, CA)

    2006-03-14T23:59:59.000Z

    A system for characterizing tissue includes the steps of generating an emission signal, generating a reference signal, directing the emission signal to and from the tissue, directing the reference signal in a predetermined manner relative to the emission signal, and using the reference signal to compensate the emission signal. In one embodiment compensation is provided for fluctuations in light delivery to the tip of the probe due to cable motion.

  1. FAQS Reference Guide- Chemical Processing

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the February 2010 edition of DOE-STD-1176-2010, Chemical Processing Functional Area Qualification Standard.

  2. FAQS Reference Guide – Emergency Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the January 2004 edition of DOE-STD-1177-2004, Emergency Management Functional Area Qualification Standard.

  3. FAQS Reference Guide – Industrial Hygiene

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the November 2007 edition of DOE-STD-1138-2007, Industrial Hygiene Functional Area Qualification Standard.

  4. FAQS Reference Guide – Construction Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the March 2004 edition of DOE-STD-1180-2004, Construction Management Functional Area Qualification Standard.

  5. FAQS Reference Guide – Environmental Compliance

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the June 2011 edition of DOE-STD-1156-2011, Environmental Compliance Functional Area Qualification Standard.

  6. Ris Energy Report 6 References Reference list for Chapter 3

    E-Print Network [OSTI]

    Risø Energy Report 6 References Reference list for Chapter 3 1. European Commission. (2007). Communication from the Commis- sion to the European Council and the European Parliament ­ An energy policy of the Brussels European Council 8/9 March 2007. Brussels. (7224/1/07 Rev. 1). 3. Danish Energy authority. (2007

  7. Appendix E References | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    NEPA Reading Room SEIS for the Production of Tritium in a Commercial Light Water Reactor Reference Documents Appendix E References Appendix E References Crosswalk of...

  8. Biocharis a relatively new concept that has been promoted primarily as a form of carbon storage but also for its poten-

    E-Print Network [OSTI]

    Biocharis a relatively new concept that has been promoted primarily as a form of carbon storage but also for its poten- tial benefits for bioenergy production (e.g., syngas, bio-oil and heat), soils allows long-term (multi-centennial) soil carbon storage, with potential benefits for agricultural

  9. UCF-4.0294 Use of University Facilities; General Requirements. (1) University facilities are reserved and used primarily for the official and regular

    E-Print Network [OSTI]

    Wu, Shin-Tson

    and approved by a University building code official or safety officer. A sketch drawing of the display are reserved and used primarily for the official and regular conduct of the University's business interference and disruption, University officials will look to the standards of University Regulation UCF- 4

  10. Asterix is a reflectometer/diffractometer/grazing-incidence-SANS/SESAME-enabled-SANS spectrometer that is primarily used for experiments or neutron scattering

    E-Print Network [OSTI]

    that is primarily used for experiments or neutron scattering techniques requiring polarized neutron beams detector arm is readily configurable for polarization or energy analysis of the scattered neutron beam be translated in the horizontal and vertical directions. Neutron detector (Spin Echo Scattering Angle

  11. POET with C++ Reference Manual

    E-Print Network [OSTI]

    Buhr, Peter Allan

    POET with #22;C++ Reference Manual University of Waterloo David Taylor and Peter A. Buhr c #3; 1996 July 23, 2006 #3; Permission is granted to make copies for personal or educational use #12; 2 POET Reference Manual Contents 1 Introduction 3 2 Before Starting POET 3 3 Accessing POET 3 4 User Interface 3 5

  12. NIST Cloud Computing Reference Architecture

    E-Print Network [OSTI]

    Perkins, Richard A.

    NIST Cloud Computing Reference Architecture Recommendations of the National Institute of Standards Publication 500-292 #12;i NIST Special Publication 500-292 NIST Cloud Computing Reference Architecture, John Messina, Lee Badger and Dawn Leaf Information Techonology Laboratory Cloud Computing Program

  13. REFERENCE CHECK QUESTIONS Candidate Name:_____________________ Date of Reference:_____________

    E-Print Network [OSTI]

    Provancher, William

    are the candidate's most significant strengths? Any areas for improvement? If you were in a position to hire:_____________ Reference Name:_____________________ Company:____________________ Conducted by:_______________________ Phone (name) handle conflict? How about pressure? Stress? Describe the candidate's productivity, commitment

  14. Volume Comparison

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at Commercial and InstitutionalArea:Mnt(N)3.1.Liquids ReserveVolume

  15. Influenza A H3N2 subtype virus NS1 protein targets into the nucleus and binds primarily via its C-terminal NLS2/NoLS to nucleolin and fibrillarin

    E-Print Network [OSTI]

    Melén, Krister; Tynell, Janne; Fagerlund, Riku; Roussel, Pascal; Hernandez-Verdun, Danièle; Julkunen, Ilkka

    2012-01-01T23:59:59.000Z

    binds primarily via its C-terminal NLS2/NoLS to nucleolinbinds primarily via its C-terminal NLS2/NoLS to nucleolinviruses possesses a C-terminal nuclear localization signal (

  16. Sandia software guidelines: Volume 5, Tools, techniques, and methodologies

    SciTech Connect (OSTI)

    Not Available

    1989-07-01T23:59:59.000Z

    This volume is one in a series of Sandia Software Guidelines intended for use in producing quality software within Sandia National Laboratories. This volume describes software tools and methodologies available to Sandia personnel for the development of software, and outlines techniques that have proven useful within the Laboratories and elsewhere. References and evaluations by Sandia personnel are included. 6 figs.

  17. FAQS Reference Guide – Occupational Safety

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the July 2011 version of DOE-STD-1160-2011, Occupational Safety Functional Area Qualification Standard.

  18. Safeguards and Security Program References

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2005-08-26T23:59:59.000Z

    The manual establishes definitions for terms related to the Department of Energy Safeguards and Security (S&S) Program and includes lists of references and acronyms/abbreviations applicable to S&S Program directives. Cancels the Safeguards and Security Glossary of Terms, dated 12-18-95. Current Safeguards and Security Program References can also be found at Safeguards and Security Policy Information Resource (http://pir.pnl.gov/)

  19. Bibliography of Utah radioactive occurrences. Volume II

    SciTech Connect (OSTI)

    Doelling, H.H. (comp.)

    1983-07-01T23:59:59.000Z

    The references in this bibliography were assembled by reviewing published bibliographies of Utah geology, unpublished reports of the US Geological Survey and the Department of Energy, and various university theses. Each of the listings is cross-referenced by location and subject matter. This report is published in two volumes.

  20. Bibliography of Utah radioactive occurrences. Volume I

    SciTech Connect (OSTI)

    Doelling, H.H. (comp.) comp.

    1983-07-01T23:59:59.000Z

    The references in this bibliography were assembled by reviewing published bibliographies of Utah geology, unpublished reports of the US Geological Survey and the Department of Energy, and various university theses. Each of the listings is cross-referenced by location and subject matter. This report is published in two volumes.

  1. REFERENCES

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn April 23, 2014, an OHASeptember 2010In addition to 1 |D I S P U T Edelivery205.1B

  2. Waste minimization handbook, Volume 1

    SciTech Connect (OSTI)

    Boing, L.E.; Coffey, M.J.

    1995-12-01T23:59:59.000Z

    This technical guide presents various methods used by industry to minimize low-level radioactive waste (LLW) generated during decommissioning and decontamination (D and D) activities. Such activities generate significant amounts of LLW during their operations. Waste minimization refers to any measure, procedure, or technique that reduces the amount of waste generated during a specific operation or project. Preventive waste minimization techniques implemented when a project is initiated can significantly reduce waste. Techniques implemented during decontamination activities reduce the cost of decommissioning. The application of waste minimization techniques is not limited to D and D activities; it is also useful during any phase of a facility`s life cycle. This compendium will be supplemented with a second volume of abstracts of hundreds of papers related to minimizing low-level nuclear waste. This second volume is expected to be released in late 1996.

  3. C++ References Kenneth I. Joy

    E-Print Network [OSTI]

    California at Davis, University of

    . It enabled me to see how to use the language to accomplish what I wanted to do. ffl Scott Meyer's Book gave plate'' member functions came very close to the ``complete class'' paradigm, that I developed from Meyer that I attempt to utilize. #12; C++ References Page 2 of 3 Lippman, Stanley B., C++ Primer, 2nd Edition

  4. Volume 71, Numbers 1 & 2 (complete)

    E-Print Network [OSTI]

    Dickson, Donald

    2013-01-01T23:59:59.000Z

    EVENTEENTH- ENTURY EWS SPRING - SUMMER 2012 Vol. 71 Nos. 1&2 Including THE NEO-LATIN NEWS Vol. 61, Nos. 1&2 SEVENTEENTH-CENTURY NEWS VOLUME 71, Nos. 1&2 SPRING-SUMMER, 2013...-begot, self-rais?d / By [their] own quickn?ing power? (PL 5.860-1), and St. Hilaire engages in an il- luminating and extended close reading of this passage. As elsewhere in the poem, Satan speaks in this passage primarily in questions, and in a nice turn...

  5. Advances in Lung Volume

    E-Print Network [OSTI]

    Jones, Michelle

    Advances in Lung Volume Reduction Surgery The Ohio University Medical Center Lung Volume Reduction LungVolumeReductionSurgery Spring 2010 © 2010 The Ohio State University Medical Center ­ 04 Consult Ohio State's #12;The Ohio State University Medical Center Lung Volume Reduction Surgery Patient

  6. The Consumption of Reference Resources

    E-Print Network [OSTI]

    G. A. White; J. A. Vaccaro; H. M. Wiseman

    2008-11-22T23:59:59.000Z

    Under the operational restriction of the U(1)-superselection rule, states that contain coherences between eigenstates of particle number constitute a resource. Such resources can be used to facilitate operations upon systems that otherwise cannot be performed. However, the process of doing this consumes reference resources. We show this explicitly for an example of a unitary operation that is forbidden by the U(1)-superselection rule.

  7. HANFORD WASTE MINERALOGY REFERENCE REPORT

    SciTech Connect (OSTI)

    DISSELKAMP RS

    2010-06-29T23:59:59.000Z

    This report lists the observed mineral phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports that used experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases observed in Hanford waste.

  8. HANFORD WASTE MINEROLOGY REFERENCE REPORT

    SciTech Connect (OSTI)

    DISSELKAMP RS

    2010-06-18T23:59:59.000Z

    This report lists the observed mineral phase phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports using experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases present observed in Hanford waste.

  9. Microgrid cyber security reference architecture.

    SciTech Connect (OSTI)

    Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

    2013-07-01T23:59:59.000Z

    This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

  10. Reference Inflow Characterization for River Resource Reference Model (RM2)

    SciTech Connect (OSTI)

    Neary, Vincent S [ORNL

    2011-12-01T23:59:59.000Z

    Sandia National Laboratory (SNL) is leading an effort to develop reference models for marine and hydrokinetic technologies and wave and current energy resources. This effort will allow the refinement of technology design tools, accurate estimates of a baseline levelized cost of energy (LCoE), and the identification of the main cost drivers that need to be addressed to achieve a competitive LCoE. As part of this effort, Oak Ridge National Laboratory was charged with examining and reporting reference river inflow characteristics for reference model 2 (RM2). Published turbulent flow data from large rivers, a water supply canal and laboratory flumes, are reviewed to determine the range of velocities, turbulence intensities and turbulent stresses acting on hydrokinetic technologies, and also to evaluate the validity of classical models that describe the depth variation of the time-mean velocity and turbulent normal Reynolds stresses. The classical models are found to generally perform well in describing river inflow characteristics. A potential challenge in river inflow characterization, however, is the high variability of depth and flow over the design life of a hydrokinetic device. This variation can have significant effects on the inflow mean velocity and turbulence intensity experienced by stationary and bottom mounted hydrokinetic energy conversion devices, which requires further investigation, but are expected to have minimal effects on surface mounted devices like the vertical axis turbine device designed for RM2. A simple methodology for obtaining an approximate inflow characterization for surface deployed devices is developed using the relation umax=(7/6)V where V is the bulk velocity and umax is assumed to be the near-surface velocity. The application of this expression is recommended for deriving the local inflow velocity acting on the energy extraction planes of the RM2 vertical axis rotors, where V=Q/A can be calculated given a USGS gage flow time-series and stage vs. cross-section area rating relationship.

  11. Reference electrode for electrolytic cell

    DOE Patents [OSTI]

    Kessie, R.W.

    1988-07-28T23:59:59.000Z

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane. 4 figs.

  12. PVWatts Version 1 Technical Reference

    SciTech Connect (OSTI)

    Dobos, A. P.

    2013-10-01T23:59:59.000Z

    The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.

  13. Tips: References | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you sure you want toworldPower 2010 1 TNews & SolarLaundryReferences Tips:

  14. References | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA Approved:AdministrationAnalysis andBHoneywell9/%2A en7/%2ANationalReferences

  15. Tips: References | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreakingMayDepartmentTest for PumpingThe| Department ofAir DuctsTips:References Tips:

  16. Site Environmental Report for 2005 Volume I and Volume II

    SciTech Connect (OSTI)

    Ruggieri, Michael

    2006-07-07T23:59:59.000Z

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, ''Environment, Safety, and Health Reporting''. The ''Site Environmental Report for 2005'' summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2005. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as ''Berkeley Lab'', ''the Laboratory'', ''Lawrence Berkeley National Laboratory'', and ''LBNL''.) The report is separated into two volumes. Volume I contains an overview of the Laboratory, the status of environmental programs, and summarized results from surveillance and monitoring activities. This year's Volume I text body is organized into an executive summary followed by six chapters. The report's structure has been reorganized this year, and it now includes a chapter devoted to environmental management system topics. Volume II contains individual data results from surveillance and monitoring activities. The ''Site Environmental Report'' is distributed by releasing it on the Web from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at http://www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. CD and printed copies of this Site Environmental Report are available upon request. The report follows the Laboratory's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current regulatory standards and is more familiar to some readers. Two tables are provided at the end of the Glossary to help readers: the first defines the prefixes used with SI units of measurement, and the second provides conversions to non-SI units.

  17. 1996 Site environmental report. Volume II

    SciTech Connect (OSTI)

    NONE

    1997-09-01T23:59:59.000Z

    Ernest Orlando Lawrence Berkeley National Laboratory presents Volume II, data appendix as a reference document to supplement the 1996 Site Environmental Report. Volume II contains the raw environmental monitoring and sampling data used to generate many of the summary results included in the main report for both routine and nonroutine activities. This appendix includes a legend that cross-references the enclosed data tables with summary tables in the main report. The legend also provides a listing of more detailed descriptions for the station location codes used in the appendices` tables. Data presented in the tables are given in Systeme International (SI) units. The glossary found in the main report contains a listing of the SI units.

  18. The International Journal of Sports Physical Therapy | Volume 8, Number 3 | June 2013 | Page 216 Purpose/Background: Functional tests have been used primarily to assess an athlete's fitness or readiness to return to sport. The

    E-Print Network [OSTI]

    Wisconsin at Madison, University of

    Intosh, MS, ATC; Alma Mattocks, MS, ATC; Phil Lentz, MS, ATC; Eric Pitkanen, MS, ATC; and Richard Rutt, PT

  19. High stability wavefront reference source

    DOE Patents [OSTI]

    Feldman, M.; Mockler, D.J.

    1994-05-03T23:59:59.000Z

    A thermally and mechanically stable wavefront reference source which produces a collimated output laser beam is disclosed. The output beam comprises substantially planar reference wavefronts which are useful for aligning and testing optical interferometers. The invention receives coherent radiation from an input optical fiber, directs a diverging input beam of the coherent radiation to a beam folding mirror (to produce a reflected diverging beam), and collimates the reflected diverging beam using a collimating lens. In a class of preferred embodiments, the invention includes a thermally and mechanically stable frame comprising rod members connected between a front end plate and a back end plate. The beam folding mirror is mounted on the back end plate, and the collimating lens mounted to the rods between the end plates. The end plates and rods are preferably made of thermally stable metal alloy. Preferably, the input optical fiber is a single mode fiber coupled to an input end of a second single mode optical fiber that is wound around a mandrel fixedly attached to the frame of the apparatus. The output end of the second fiber is cleaved so as to be optically flat, so that the input beam emerging therefrom is a nearly perfect diverging spherical wave. 7 figures.

  20. Computer News, Volume 3

    E-Print Network [OSTI]

    [mandelbrot set] MATH DEPT Computer News, Volume 3. How to take advantage of the newer, faster machines on our network ...

  1. Computer News, Volume 2

    E-Print Network [OSTI]

    [mandelbrot set] MATH DEPT Computer News, Volume 2. How to handle .pdf files on the web: acroread, distill, and Netscape ...

  2. FY 1996 solid waste integrated life-cycle forecast characteristics summary. Volumes 1 and 2

    SciTech Connect (OSTI)

    Templeton, K.J.

    1996-05-23T23:59:59.000Z

    For the past six years, a waste volume forecast has been collected annually from onsite and offsite generators that currently ship or are planning to ship solid waste to the Westinghouse Hanford Company`s Central Waste Complex (CWC). This document provides a description of the physical waste forms, hazardous waste constituents, and radionuclides of the waste expected to be shipped to the CWC from 1996 through the remaining life cycle of the Hanford Site (assumed to extend to 2070). In previous years, forecast data has been reported for a 30-year time period; however, the life-cycle approach was adopted this year to maintain consistency with FY 1996 Multi-Year Program Plans. This document is a companion report to two previous reports: the more detailed report on waste volumes, WHC-EP-0900, FY1996 Solid Waste Integrated Life-Cycle Forecast Volume Summary and the report on expected containers, WHC-EP-0903, FY1996 Solid Waste Integrated Life-Cycle Forecast Container Summary. All three documents are based on data gathered during the FY 1995 data call and verified as of January, 1996. These documents are intended to be used in conjunction with other solid waste planning documents as references for short and long-term planning of the WHC Solid Waste Disposal Division`s treatment, storage, and disposal activities over the next several decades. This document focuses on two main characteristics: the physical waste forms and hazardous waste constituents of low-level mixed waste (LLMW) and transuranic waste (both non-mixed and mixed) (TRU(M)). The major generators for each waste category and waste characteristic are also discussed. The characteristics of low-level waste (LLW) are described in Appendix A. In addition, information on radionuclides present in the waste is provided in Appendix B. The FY 1996 forecast data indicate that about 100,900 cubic meters of LLMW and TRU(M) waste is expected to be received at the CWC over the remaining life cycle of the site. Based on ranges provided by the waste generators, this baseline volume could fluctuate between a minimum of about 59,720 cubic meters and a maximum of about 152,170 cubic meters. The range is primarily due to uncertainties associated with the Tank Waste Remediation System (TWRS) program, including uncertainties regarding retrieval of long-length equipment, scheduling, and tank retrieval technologies.

  3. National Environmental Information Infrastructure Reference Architecture

    E-Print Network [OSTI]

    Greenslade, Diana

    National Environmental Information Infrastructure Reference Architecture Consultation Draft Environmental Information Infrastructure Reference Architecture: Consultation Draft Environmental Information Architecture: Consultation Draft, Bureau of Meteorology, Canberra, Australia, pp. 52. With the exception

  4. Cross-References Applications of Nanofluidics

    E-Print Network [OSTI]

    Zhigilei, Leonid V.

    Cross-References Applications of Nanofluidics Electrokinetic Fluid Flow in Nanostructures Micro/Nano Flow Characterization Techniques Nanochannels for Nanofluidics: Fabrication Aspects Rapid Electrokinetic Patterning References 1. Conlisk, A.T.: Essentials of Micro and Nanofluidics with Application

  5. Economic Impact of Standard Reference Materials

    E-Print Network [OSTI]

    00-1 Planning Report Economic Impact of Standard Reference Materials for Sulfur in Fossil Fuels Administration #12;February 2000 Economic Impact of Standard Reference Materials for Sulfur in Fossil Fuels Final-006 Economic Impact of Standard Reference Materials for Sulfur in Fossil Fuels Final Report February 2000

  6. Reference Phase of Fresnel Zone Plates

    E-Print Network [OSTI]

    G. W. Webb

    2003-02-28T23:59:59.000Z

    The standard zone plate assumes that the shortest ray connecting a radiation source and a detection point has a phase of 0 deg thereby defining a reference phase. Here we examine the experimental consequences of varying this reference phase from 0 deg to 360 deg. It is concluded that reference phase is an intrinsic and useful property of zone plates.

  7. Transitioning to a Lean Enterprise: A Guide for Leaders, Volume III, Roadmap Explorations

    E-Print Network [OSTI]

    Bozdogan, Kirk

    2000-01-01T23:59:59.000Z

    Volume III of this guide may be used as an in-depth reference source for acquiring deep knowledge about many of the aspects of transitioning to lean. Lean change agents and lean implementation leaders should find this ...

  8. Transitioning to a Lean Enterprise: A Guide for Leaders, Volume II, Transition-to-Lean Roadmap

    E-Print Network [OSTI]

    Lean Advancement Initiative

    2000-01-01T23:59:59.000Z

    Volume II of this guide is a standalone reference model for assisting lean change agents and lean implementation teams in transforming the enterprise to a lean state. It is also of value to enterprise leaders and senior ...

  9. ILC cryogenic systems reference design

    SciTech Connect (OSTI)

    Peterson, T.J.; Geynisman, M.; Klebaner, A.; Theilacker, J.; /Fermilab; Parma, V.; Tavian, L.; /CERN

    2008-01-01T23:59:59.000Z

    A Global Design Effort (GDE) began in 2005 to study a TeV scale electron-positron linear accelerator based on superconducting radio-frequency (RF) technology, called the International Linear Collider (ILC). In early 2007, the design effort culminated in a reference design for the ILC, closely based on the earlier TESLA design. The ILC will consist of two 250 GeV linacs, which provide positron-electron collisions for high energy physics research. The particle beams will be accelerated to their final energy in superconducting niobium RF cavities operating at 2 kelvin. At a length of about 12 km each, the main linacs will be the largest cryogenic systems in the ILC. Positron and electron sources, damping rings, and beam delivery systems will also have a large number and variety of other superconducting RF cavities and magnets, which require cooling at liquid helium temperatures. Ten large cryogenic plants with 2 kelvin refrigeration are envisioned to cool the main linacs and the electron and positron sources. Three smaller cryogenic plants will cool the damping rings and beam delivery system components predominately at 4.5 K. This paper describes the cryogenic systems concepts for the ILC.

  10. Spent Fuel Working Group Report. Volume 1

    SciTech Connect (OSTI)

    O`Toole, T.

    1993-11-01T23:59:59.000Z

    The Department of Energy is storing large amounts of spent nuclear fuel and other reactor irradiated nuclear materials (herein referred to as RINM). In the past, the Department reprocessed RINM to recover plutonium, tritium, and other isotopes. However, the Department has ceased or is phasing out reprocessing operations. As a consequence, Department facilities designed, constructed, and operated to store RINM for relatively short periods of time now store RINM, pending decisions on the disposition of these materials. The extended use of the facilities, combined with their known degradation and that of their stored materials, has led to uncertainties about safety. To ensure that extended storage is safe (i.e., that protection exists for workers, the public, and the environment), the conditions of these storage facilities had to be assessed. The compelling need for such an assessment led to the Secretary`s initiative on spent fuel, which is the subject of this report. This report comprises three volumes: Volume I; Summary Results of the Spent Fuel Working Group Evaluation; Volume II, Working Group Assessment Team Reports and Protocol; Volume III; Operating Contractor Site Team Reports. This volume presents the overall results of the Working Group`s Evaluation. The group assessed 66 facilities spread across 11 sites. It identified: (1) facilities that should be considered for priority attention. (2) programmatic issues to be considered in decision making about interim storage plans and (3) specific vulnerabilities for some of these facilities.

  11. Guidelines for the verification and validation of expert system software and conventional software: Bibliography. Volume 8

    SciTech Connect (OSTI)

    Miller, L.A.; Hayes, J.E.; Mirsky, S.M. [Science Applications International Corp., McLean, VA (United States)

    1995-03-01T23:59:59.000Z

    This volume contains all of the technical references found in Volumes 1-7 concerning the development of guidelines for the verification and validation of expert systems, knowledge-based systems, other AI systems, object-oriented systems, and conventional systems.

  12. Computer News, Volume 21

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 21. I came, I saw, ical. There's a great new calendar and appointment book program on our system called ical at.

  13. Computer News, Volume 1

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 1. You and your .cshrc file. Click on RELOAD now. This page is frequently updated and you might be looking at an old ...

  14. Computer News, Volume 36

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 36. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

  15. Computer News, Volume 19

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 19. Those damned attachments! I explain here how to extract and decode e-mail attachments of various kinds. Click on ...

  16. Computer News, Volume 8

    E-Print Network [OSTI]

    [mandelbrot set] MATH DEPT Computer News, Volume 8. A convenient way to do e-mail from home. by guest columnist, Donu Arapura ...

  17. Computer News, Volume 20

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 20. You and your .forward file. Let's say your name is Steven Bellisandagorapahockey and your login id on math is sbellis ...

  18. Computer News, Volume 37

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 37. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

  19. Computer News, Volume 13

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 13. How to dork your official classlist. Click on RELOAD now. This page is frequently updated and you might be looking at ...

  20. Computer News, Volume 15

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 15. How to gain access to Mathematica on a math dept SUN. Click on RELOAD now. This page is frequently updated and ...

  1. Computer News, Volume 34

    E-Print Network [OSTI]

    [mandelbrot set] MATH DEPT Computer News, Volume 34. Click on RELOAD now. This page is frequently updated and you might be looking at an old version

  2. Computer News, Volume 33

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 33. How I teach big calculus lectures with a tablet PC. Click on RELOAD now. This page is frequently updated and you ...

  3. Computer News, Volume 12

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 12. Quick and dirty math on the internet. Click on RELOAD now. This page is frequently updated and you might be ...

  4. Computer News, Volume 38

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 38. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

  5. Computer News, Volume 27

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 27. How to approve Plans of Study on the web. First, make sure you know your Purdue Career Account Login and ...

  6. Computer News, Volume 4

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 4. Xess, the spreadsheet. Click on RELOAD now. This page is frequently updated and you might be looking at an old ...

  7. Computer News, Volume 2

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 2. How to add acroread and distill to your path. Click on RELOAD now. This page is frequently updated and you might be ...

  8. Computer News, Volume 35

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 34. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

  9. Computer News, Volume 32

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 32. The new TeX and how to create the new PU Math letterhead stationery. with help from Brad Lucier, Rodrigo Bañuelos

  10. Computer News, Volume 39

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 39. Click on RELOAD now. This page is frequently updated and you might be looking at an old version saved by your ...

  11. Computer News, Volume 23

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 23. How to view e-mail formatted in HTML originating from the web. Click on RELOAD now. This page is frequently ...

  12. Prime Supplier Sales Volumes

    Gasoline and Diesel Fuel Update (EIA)

    Sales Volumes of Motor Gasoline by Grade, Formulation, PAD District, and State 356 Energy Information Administration Petroleum Marketing Annual 1996 Table 48. Prime...

  13. Prime Supplier Sales Volumes

    Gasoline and Diesel Fuel Update (EIA)

    Sales Volumes of Motor Gasoline by Grade, Formulation, PAD District, and State 356 Energy Information Administration Petroleum Marketing Annual 1997 Table 48. Prime...

  14. LANL Volume 2_Final

    Broader source: Energy.gov (indexed) [DOE]

    42 LANL * Consider developing programmatic evaluation criteria based on the October 1999 draft of Volume VI, Emergency Management Evaluations, of the DOE emergency...

  15. Finite Volume Element Method

    E-Print Network [OSTI]

    2003-12-06T23:59:59.000Z

    FVE is closely related to the control volume finite element method ... simple stencils, to apply to a fairly wide range of fluid flow equations, to effectively treat.

  16. Advanced Thermionic Technology Program: summary report. Volume 1. Final report

    SciTech Connect (OSTI)

    Not Available

    1984-10-01T23:59:59.000Z

    This report summarizes the progress made by the Advanced Thermionic Technology Program during the past several years. This program, sponsored by the US Department of Energy, has had as its goal adapting thermionic devices to generate electricity in a terrestrial (i.e., combustion) environment. The technology has previously been developed for astronautical applications. The report is organized in four volumes, each focused as much as possible on the needs of a particular audience. Volume 1 contains Part A, the Executive Summary. This Executive Summary describes the accomplishments of the Program in brief, but assumes the reader's familiarity with the thermionic process and the technical issues associated with the Program. For this reason, Volume 1 also contains Part B, a minimally technical overview of the Advanced Thermionic Technology Program. Volume 2 (Part C) concentrates on the progress made in developing and fabricating the ''current generation'' of chemical vapor deposited hot shell thermionic converters and is addressed to those primarily concerned with today's capabilities in terrestrial thermionic technology. Volume 3 (Part D) contains the results of systems studies of primary interest to those involved in identifying and evaluating applications for thermionics. Volume 4 (Part E) is a highly technical discussion of the attempts made by the program to push the state-of-the-art beyond the current generation of converters and is directed toward potential researchers engaged in this same task. These technical discussions are complemented with Appendices where appropriate.

  17. A Short Reference Grammar of Standard Slovene

    E-Print Network [OSTI]

    Greenberg, Marc L.

    2006-01-01T23:59:59.000Z

    A reference grammar of the Slovene language designed for advanced-level language users and linguists to compare semantic categories across languages.

  18. Sandia National Laboratories: Reference Model 3

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reference Model 3 Sandia, NREL Release Wave Energy Converter Modeling and Simulation Code: WEC-Sim On July 29, 2014, in Computational Modeling & Simulation, Energy, News, News &...

  19. FAQS Reference Guide – General Technical Base

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the December 2007 edition of DOE-STD-1146-2007, General Technical Base Functional Area Qualification Standard.

  20. Sandia National Laboratories: Reference Model Project

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    marine hydrokinetic (MHK) reference models (RMs) for wave energy converters and tidal, ocean, and river current energy converters. The RMP team includes a partnership between...

  1. Sandia National Laboratories: marine hydrokinetic reference models

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    marine hydrokinetic (MHK) reference models (RMs) for wave energy converters and tidal, ocean, and river current energy converters. The RMP team includes a partnership between...

  2. Supplementary Materials for: Journal of Neuroscience Volume X, pages X-X, 2011

    E-Print Network [OSTI]

    Crawford, Doug

    -vectorrepresentationofeye position. H V V H B. T Supplementary Materials 3 #12;2 sin=q (3) Thus, the overall formSupplementary Materials for: Journal of Neuroscience Volume X, pages X-X, 2011 Intrinsic reference in the Crawford lab, for identification of intrinsic reference frames of SC visuomotor receptive fields during

  3. FAQS Reference Guide - Quality Assurance | Department of Energy

    Office of Environmental Management (EM)

    Reference Guide - Quality Assurance FAQS Reference Guide - Quality Assurance This reference guide has been developed to address the competency statements in the April 2002 edition...

  4. 1994 Solid waste forecast container volume summary

    SciTech Connect (OSTI)

    Templeton, K.J.; Clary, J.L.

    1994-09-01T23:59:59.000Z

    This report describes a 30-year forecast of the solid waste volumes by container type. The volumes described are low-level mixed waste (LLMW) and transuranic/transuranic mixed (TRU/TRUM) waste. These volumes and their associated container types will be generated or received at the US Department of Energy Hanford Site for storage, treatment, and disposal at Westinghouse Hanford Company`s Solid Waste Operations Complex (SWOC) during a 30-year period from FY 1994 through FY 2023. The forecast data for the 30-year period indicates that approximately 307,150 m{sup 3} of LLMW and TRU/TRUM waste will be managed by the SWOC. The main container type for this waste is 55-gallon drums, which will be used to ship 36% of the LLMW and TRU/TRUM waste. The main waste generator forecasting the use of 55-gallon drums is Past Practice Remediation. This waste will be generated by the Environmental Restoration Program during remediation of Hanford`s past practice sites. Although Past Practice Remediation is the primary generator of 55-gallon drums, most waste generators are planning to ship some percentage of their waste in 55-gallon drums. Long-length equipment containers (LECs) are forecasted to contain 32% of the LLMW and TRU/TRUM waste. The main waste generator forecasting the use of LECs is the Long-Length Equipment waste generator, which is responsible for retrieving contaminated long-length equipment from the tank farms. Boxes are forecasted to contain 21% of the waste. These containers are primarily forecasted for use by the Environmental Restoration Operations--D&D of Surplus Facilities waste generator. This waste generator is responsible for the solid waste generated during decontamination and decommissioning (D&D) of the facilities currently on the Surplus Facilities Program Plan. The remaining LLMW and TRU/TRUM waste volume is planned to be shipped in casks and other miscellaneous containers.

  5. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  6. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  7. Physics 321 Accelerating Reference Frames II

    E-Print Network [OSTI]

    Hart, Gus

    Physics 321 Hour 25 Accelerating Reference Frames II Consider an accelerating train car Proof 0 and S is a frame rotating with angular velocity . Examples Handout rotation.nb #12;Physics 321 Hour 26 Accelerating Reference Frames III Velocities in Rotating Frames in S0 basis in S' basis In S' basis in S0 basis

  8. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  9. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  10. Degradation of a quantum reference frame

    E-Print Network [OSTI]

    Stephen D. Bartlett; Terry Rudolph; Robert W. Spekkens; Peter S. Turner

    2006-04-20T23:59:59.000Z

    We investigate the degradation of reference frames, treated as dynamical quantum systems, and quantify their longevity as a resource for performing tasks in quantum information processing. We adopt an operational measure of a reference frame's longevity, namely, the number of measurements that can be made against it with a certain error tolerance. We investigate two distinct types of reference frame: a reference direction, realized by a spin-j system, and a phase reference, realized by an oscillator mode with bounded energy. For both cases, we show that our measure of longevity increases quadratically with the size of the reference system and is therefore non-additive. For instance, the number of measurements that a directional reference frame consisting of N parallel spins can be put to use scales as N^2. Our results quantify the extent to which microscopic or mesoscopic reference frames may be used for repeated, high-precision measurements, without needing to be reset - a question that is important for some implementations of quantum computing. We illustrate our results using the proposed single-spin measurement scheme of magnetic resonance force microscopy.

  11. Libraries Reference Copyright 1996 -2003 Intel Corporation

    E-Print Network [OSTI]

    Fossati, Giovanni

    Intel® Fortran Libraries Reference Copyright © 1996 - 2003 Intel Corporation All Rights Reserved PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustain- ing applications. This Intel® Fortran Libraries Reference as well as the software described in it is furnished

  12. Archived Reference Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  15. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  17. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  18. Factors Affecting Prostate Volume Estimation in Computed Tomography Images

    SciTech Connect (OSTI)

    Yang, Cheng-Hsiu [Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan (China); Wang, Shyh-Jen [Divisions of Experimental Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan (China); Institute of Biomedical Engineering, National Yang Ming University, Taipei, Taiwan (China); Lin, Alex Tong-Long [Divisions of Urology, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan (China); Lin, Chao-An, E-mail: calin@pme.nthu.edu.t [Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan (China)

    2011-04-01T23:59:59.000Z

    The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within {+-} 3 cm{sup 3}, regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.

  19. Computer News, Volume 29

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 29. How to update your login shell from csh to tcsh. If you, like me, have had an account on the Math network of SUNs ...

  20. Computer News, Volume 30

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 30. How to create an ASCII version of the Purdue Logo and other matters of e-mail etiquette. The Purdue logo... ... ah, yes ...

  1. Computer News, Volume 26

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 26. How to trim an e-mail alias. The faculty e-mail alias has a lot more people on it than you might imagine. (To find out ...

  2. Computer News, Volume 7

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 7. How to put figures in TeX. (I assume that you are using X windows on or from a math dept SUN.) To make a figure, I use ...

  3. Computer News, Volume 31

    E-Print Network [OSTI]

    MATH DEPT Computer News, Volume 31. How to create .pdf files from TeX. by Donu Arapura. Click on RELOAD now. This page is frequently updated and you ...

  4. Imaging using volume holograms

    E-Print Network [OSTI]

    Sinha, Arnab, 1978-

    2004-01-01T23:59:59.000Z

    Volume holograms can be thought of as self-aligned 3D stacks of diffractive elements that operate coherently on incident fields as they propagate through the structure. In this thesis, we propose, design and implement ...

  5. Advanced Thermionic Technology Program: summary report. Volume 2. Final report

    SciTech Connect (OSTI)

    Not Available

    1984-10-01T23:59:59.000Z

    This report summarizes the progress made by the Advanced Thermionic Technology Program during the past several years. This Program, sponsored by the US Department of Energy, has had as its goal adapting thermionic devices to generate electricity in a terrestrial (i.e., combustion) environment. The technology has previously been developed for astronautical applications. Volume 2 (Part C) concentrates on the progress made in developing and fabricating the ''current generation'' of chemical vapor deposited hot shell thermionic converters and is addressed to those primarily concerned with today's capabilities in terrestrial thermionic technology. 30 refs., 83 figs.

  6. Disclaimer: These standards and guidelines are designed primarily as an educational resource for physicians to help them provide quality clinical services. Adherence to these standards and guidelines does not necessarily ensure a successful medical outcom

    E-Print Network [OSTI]

    Levin, Judith G.

    for physicians to help them provide quality clinical services. Adherence to these standards and guidelines doesDisclaimer: These standards and guidelines are designed primarily as an educational resource not necessarily ensure a successful medical outcome. These standards and guidelines should not be considered

  7. ILC Reference Design Report: Accelerator Executive Summary

    SciTech Connect (OSTI)

    Phinney, Nan; /SLAC

    2007-12-14T23:59:59.000Z

    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radiofrequency (SCRF) accelerating cavities. The use of the SCRF technology was recommended by the International Technology Recommendation Panel (ITRP) in August 2004 [1], and shortly thereafter endorsed by the International Committee for Future Accelerators (ICFA). In an unprecedented milestone in high-energy physics, the many institutes around the world involved in linear collider R&D united in a common effort to produce a global design for the ILC. In November 2004, the 1st International Linear Collider Workshop was held at KEK, Tsukuba, Japan. The workshop was attended by some 200 accelerator physicists from around the world, and paved the way for the 2nd ILC Workshop in August 2005, held at Snowmass, Colorado, USA, where the ILC Global Design Effort (GDE) was officially formed. The GDE membership reflects the global nature of the collaboration, with accelerator experts from all three regions (Americas, Asia and Europe). The first major goal of the GDE was to define the basic parameters and layout of the machine--the Baseline Configuration. This was achieved at the first GDE meeting held at INFN, Frascati, Italy in December 2005 with the creation of the Baseline Configuration Document (BCD). During the next 14 months, the BCD was used as the basis for the detailed design work and value estimate (as described in section 1.6) culminating in the completion of the second major milestone, the publication of the draft ILC Reference Design Report (RDR). The technical design and cost estimate for the ILC is based on two decades of world-wide Linear Collider R&D, beginning with the construction and operation of the SLAC Linear Collider (SLC). The SLC is acknowledged as a proof-of-principle machine for the linear collider concept. The ILC SCRF linac technology was pioneered by the TESLA collaboration*, culminating in a proposal for a 500 GeV center-of-mass linear collider in 2001 [2]. The concurrent (competing) design work on a normal conducting collider (NLC with X-band [3] and GLC with X- or C-Band [4]), has advanced the design concepts for the ILC injectors, Damping Rings (DR) and Beam Delivery System (BDS), as well as addressing overall operations, machine protection and availability issues. The X- and C-band R&D has led to concepts for the RF power source that may eventually produce either cost and/or performance benefits. Finally, the European XFEL [5] to be constructed at DESY, Hamburg, Germany, will make use of the TESLA linac technology, and represents a significant on-going R&D effort which remains of great benefit for the ILC. The current ILC baseline assumes an accelerating gradient of 31.5 MV/m to achieve a centre-of-mass energy of 500 GeV. The high luminosity requires the use of high power and small emittance beams. The choice of 1.3 GHz SCRF is well suited to the requirements, primarily because the very low power loss in the SCRF cavity walls allows the use of long RF pulses, relaxing the requirements on the peak-power generation, and ultimately leading to high wall-plug to beam transfer efficiency. The primary cost drivers are the SCRF Main Linac technology and the Conventional Facilities (including civil engineering). The choice of gradient is a key cost and performance parameter, since it dictates the length of the linacs, while the cavity quality factor (Q{sub 0}) relates to the required cryogenic cooling power. The achievement of 31.5 MV/m as the baseline average operational accelerating gradient--requiring a minimum performance of 35 MV/m during cavity mass-production acceptance testing--represents the primary challenge to the global ILC R&D With the completion of the RDR, the GDE will shortly begin an engineering design study, closely coupled with a prioritized R&D program. The goal is to produce an Engineering Design Report (EDR) demonstrating readiness for construction by 2010, followed by start of construction in 2012. A seve

  8. WSU's conservation program is primarily driven by the desire to minimize impacts on water resources, namely the regional aquifer, and to meet regulatory requirements. The official goal is to

    E-Print Network [OSTI]

    Collins, Gary S.

    Consumption (AC) ­ Annual Volume 491,735,000Total Water Produced and Purchased (TP) ­ Annual Volume was commissioned in April 2009. The construction of this facility utilizes water filtration and chemical treatment period listed above, WSU total water produced was 491.7 million gallons which is 70.25 million gallons

  9. Introducing Reference Semantics via Refinement Graeme Smith

    E-Print Network [OSTI]

    Smith, Graeme

    Introducing Reference Semantics via Refinement Graeme Smith Software Verification Research Centre, University of Queensland, Australia smith@svrc.uq.edu.au Abstract. Two types of semantics have been given

  10. An expectation model of referring expressions

    E-Print Network [OSTI]

    Kræmer, John, Ph. D. Massachusetts Institute of Technology

    2010-01-01T23:59:59.000Z

    This thesis introduces EMRE, an expectation-based model of referring expressions. EMRE is proposed as a model of non-syntactic dependencies - in particular, discourse-level semantic dependencies that bridge sentence gaps. ...

  11. Archive Reference Buildings by Building Type: Supermarket

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  12. Archive Reference Buildings by Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  13. Generating and interpreting referring expressions in context

    E-Print Network [OSTI]

    Smith, Dustin Arthur

    2013-01-01T23:59:59.000Z

    Referring expressions with vague and ambiguous modifiers, such as "a quick visit" and "the big meeting," are difficult for computers to interpret because their meanings are defined in part by context. For the hearer to ...

  14. Clause chaining, switch reference and coordination

    E-Print Network [OSTI]

    Nonato, Rafael

    2014-01-01T23:59:59.000Z

    In this thesis I ponder over a constellation of phenomena that revolve around switch reference and coordination, drawing mainly on their instantiation in Kisedje (Je, Brazil). I start by investigating Klsedje's case system. ...

  15. Libraries Reference Document Number: 253262-002

    E-Print Network [OSTI]

    Talbot, James P.

    Intel® Fortran Libraries Reference Document Number: 253262-002 World Wide Web: http PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, or life sustain- ing.................................................................................... xxiv Chapter 1 Overview of the Libraries Portability Routines

  16. Integrating Referring and Informing in NP Planning 

    E-Print Network [OSTI]

    O'Donnell, Michael; Knott, Alistair; Hitzeman, Janet; Cheng, Hua

    Two of the functions of an NP are to refer (identify a particular entity) and to inform (provide new information about an entity). While many NPs may serve only one of these functions, some NPs conflate the functions, ...

  17. FAQS Reference Guide – Safety Software Quality Assurance

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the (March 2011) edition of DOE-STD-1172-2011, Safety Software Quality Assurance Functional Area Qualification Standard.

  18. Defining Reference Information for Restoring Ecologically Rare

    E-Print Network [OSTI]

    . In particular, we assess the constraints that arise when refer- ence information from various sources is ei type that occurs across temperate and tropical regions and is characterized by scattered, open- grown

  19. Quantum communication, reference frames and gauge theory

    E-Print Network [OSTI]

    S. J. van Enk

    2006-04-26T23:59:59.000Z

    We consider quantum communication in the case that the communicating parties not only do not share a reference frame but use imperfect quantum communication channels, in that each channel applies some fixed but unknown unitary rotation to each qubit. We discuss similarities and differences between reference frames within that quantum communication model and gauge fields in gauge theory. We generalize the concept of refbits and analyze various quantum communication protocols within the communication model.

  20. "Analysis of SOFCs using reference electrodes?

    SciTech Connect (OSTI)

    Finklea, Harry; Chen,Xiaoke; Gerdes,Kirk; Pakalapati, Suryanarayana; Celik, Ismail

    2013-07-01T23:59:59.000Z

    Reference electrodes are frequently applied to isolate the performance of one electrode in a solid oxide fuel cell. However, reference electrode simulations raise doubt to veracity of data collected using reference electrodes. The simulations predict that the reported performance for the one electrode will frequently contain performance of both electrodes. Nonetheless, recent reports persistently treat data so collected as ideally isolated. This work confirms the predictions of the reference electrode simulations on two SOFC designs, and to provides a method of validating the data measured in the 3-electrode configuration. Validation is based on the assumption that a change in gas composition to one electrode does not affect the impedance of the other electrode at open circuit voltage. This assumption is supported by a full physics simulation of the SOFC. Three configurations of reference electrode and cell design are experimentally examined using various gas flows and two temperatures. Impedance data are subjected to deconvolution analysis and equivalent circuit fitting and approximate polarization resistances of the cathode and anode are determined. The results demonstrate that the utility of reference electrodes is limited and often wholly inappropriate. Reported impedances and single electrode polarization values must be scrutinized on this basis.

  1. Solidification of low-volume power plant sludges. Final report

    SciTech Connect (OSTI)

    Bell, N.E.; Halverson, M.A.; Mercer, B.M.

    1981-12-01T23:59:59.000Z

    A literature review was conducted to obtain information on the status of hazardous waste solidification technology and application of this technology to low-volume power plant waste sludges. Because of scarcity of sludge composition data, anticipated major components were identified primarily by chemical reactions that are known to occur during treatment of specific wastewaters. Chemical and physical properties of these sludges were critically analyzed for compatibility with several types of commercially available solidification processes. The study pointed out the need for additional information on the nature of these sludges, especially leaching characteristics and the presence of substances that will interfere with solidification processes. Laboratory studies were recommended for evaluation of solidification process which have the greatest potential for converting hazardous low-volume sludges to non-hazardous waste forms.

  2. System analysis of shallow land burial. Volume 2: technical background. Technical report, 26 November 1979-23 January 1981

    SciTech Connect (OSTI)

    Lester, D.; Buckley, D.; Donelson, S.; Dura, V.; Hecht, M.

    1981-03-01T23:59:59.000Z

    This is volume two of a three volume set detailing the activities and results of the System Analysis of Shallow Land Burial Project. Activities under four project tasks are described: Task 1 - Identify Potential Radionuclide Release Pathways, Task 2 - Systems Model for Shallow Land Burial of Low-Level Waste, Task 3 - Sensitivity and Optimization Study and Task 4 - Reference Facility Dose Assessment.

  3. Portugal and United States cooperative energy assessment. Volume 3. Reference reports, Part 1

    SciTech Connect (OSTI)

    Not Available

    1981-09-01T23:59:59.000Z

    Statistical data on energy production and consumption and supporting information were obtained from US Bureau of Mines records supplemented by additional data obtained in Portugal. Geologic descriptions and analysis of known areas and of areas having possible future potential have been prepared by the US Geological Survey. Portugal lacks sufficient indigenous supplies of organic fuels to meet its energy demands, and so must import large quantities of petroleum and coal. Approximately 80% of Portugal's electric energy is produced by hydroelectric stations; thermal stations produce the other 20%. Portugal has produced no crude oil, natural gas, or condensate; no resources or reserves in these categories are listed for Portugal in the 1976 World Energy Conference report. Until the last year or so (1980), no significant onshore petroleum exploration had been done in Portugal since 1963. Production of coal in Portugal has declined steadily to the present annual yield of about 200,000 metric tons. On the basis of estimates in only three coal fields, resources of coal of all ranks in Portugal total at least 76 million (10/sup 6/) metric tons. Uranium is mined near Viseu and Guarda in the northern part of Portugal; the Nisa mine in east-central Portugal will begin producing uranium ore in 1985 after installation of a processing plant. Portugal produced 95 metric tons of uranium oxide (U/sub 3/O/sub 8/) from ore stocks in each year from 1972 through 1974; production is assumed to have continued at the same rate since then. Geothermal energy has not been developed in mainland Portugal; however, hot springs that may have geothermal energy potential are known in the Minho district in the northwest. Geothermal energy resources exist in the Azores and a program of evaluation and exploration with technical assistance from the USGS is presently in progress there.

  4. Proposed site treatment plan (PSTP) Volumes I & II & reference document, Revision 3

    SciTech Connect (OSTI)

    Helmich, E.; Noller, D.K.; Wierzbicki, K.S. [and others

    1995-09-27T23:59:59.000Z

    The Federal Facility Compliance Act requires the Department of Energy to undertake a national effort to develop Site Treatment Plans for each of its sites generating or storing mixed waste. Mixed waste contains both a hazardous waste subject to the Resource Conservation and Recovery Act and radioactive material subject to the Atomic Energy Act of 1954. The Site Treatment Plan for the Savannah River Site proposes how SRS will treat mixed waste that is now stored on the site and mixed waste that Will be generated in the future. Also, the Site Treatment Plan identifies Savannah River Site mixed wastes that other Department of Energy facilities could treat and mixed waste from other facilities that the Savannah River Site could treat. The Site Treatment Plan has been approved by the State of South Carolina. The Department of Energy Will enter into a consent order with the State of South Carolina by October 6, 1995. The consent order will contain enforceable commitments to treat mixed waste.

  5. International Linear Collider Reference Design Report Volume 2: Physics at the ILC

    SciTech Connect (OSTI)

    Aarons, Gerald; Abe, Toshinori; Abernathy, Jason; Ablikim, Medina; Abramowicz, Halina; Adey, David; Adloff, Catherine; Adolphsen, Chris; Afanaciev, Konstantin; Agapov, Ilya; Ahn, Jung-Keun; Aihara, Hiroaki; Akemoto, Mitsuo; del Carmen Alabau, Maria; Albert, Justin; Albrecht, Hartwig; Albrecht, Michael; Alesini, David; Alexander, Gideon; Alexander, Jim; Allison, Wade; /SLAC /Tokyo U. /Victoria U. /Beijing, Inst. High Energy Phys. /Tel Aviv U. /Birmingham U. /Annecy, LAPP /Minsk, High Energy Phys. Ctr. /DESY /Royal Holloway, U. of London /CERN /Pusan Natl. U. /KEK, Tsukuba /Orsay, LAL /Notre Dame U. /Frascati /Cornell U., Phys. Dept. /Oxford U. /Hefei, CUST /Bangalore, Indian Inst. Sci. /Fermilab

    2011-11-14T23:59:59.000Z

    The triumph of 20th century particle physics was the development of the Standard Model and the confirmation of many of its aspects. Experiments determined the particle constituents of ordinary matter, and identified four forces that hold matter together and transform it from one form to another. Particle interactions were found to obey precise laws of relativity and quantum theory. Remarkable features of quantum physics were observed, including the real effects of 'virtual' particles on the visible world. Building on this success, particle physicists are now able to address questions that are even more fundamental, and explore some of the deepest mysteries in science. The scope of these questions is illustrated by this summary from the report Quantum Universe: (1) Are there undiscovered principles of nature; (2) How can we solve the mystery of dark energy; (3) Are there extra dimensions of space; (4) Do all the forces become one; (5) Why are there so many particles; (6) What is dark matter? How can we make it in the laboratory; (7) What are neutrinos telling us; (8) How did the universe begin; and (9) What happened to the antimatter? A worldwide program of particle physics investigations, using multiple approaches, is already underway to explore this compelling scientific landscape. As emphasized in many scientific studies, the International Linear Collider is expected to play a central role in what is likely to be an era of revolutionary advances. Discoveries from the ILC could have breakthrough impact on many of these fundamental questions. Many of the scientific opportunities for the ILC involve the Higgs particle and related new phenomena at Terascale energies. The Standard Model boldly hypothesizes a new form of Terascale energy, called the Higgs field, that permeates the entire universe. Elementary particles acquire mass by interacting with this field. The Higgs field also breaks a fundamental electroweak force into two forces, the electromagnetic and weak forces, which are observed by experiments in very different forms. So far, there is no direct experimental evidence for a Higgs field or the Higgs particle that should accompany it. Furthermore, quantum effects of the type already observed in experiments should destabilize the Higgs boson of the Standard Model, preventing its operation at Terascale energies. The proposed antidotes for this quantum instability mostly involve dramatic phenomena at the Terascale: new forces, a new principle of nature called supersymmetry, or even extra dimensions of space. Thus for particle physicists the Higgs boson is at the center of a much broader program of discovery, taking off from a long list of questions. Is there really a Higgs boson? If not, what are the mechanisms that give mass to particles and break the electroweak force? If there is a Higgs boson, does it differ from the hypothetical Higgs of the Standard Model? Is there more than one Higgs particle? What are the new phenomena that stabilize the Higgs boson at the Terascale? What properties of Higgs boson inform us about these new phenomena? Another major opportunity for the ILC is to shed light on the dark side of the universe. Astrophysical data shows that dark matter dominates over visible matter, and that almost all of this dark matter cannot be composed of known particles. This data, combined with the concordance model of Big Bang cosmology, suggests that dark matter is comprised of new particles that interact weakly with ordinary matter and have Terascale masses. It is truely remarkable that astrophysics and cosmology, completely independently of the particle physics considerations reviewed above, point to new phenomena at the Terascale. If Terascale dark matter exists, experiments at the ILC should be able to produce such particles in the laboratory and study their properties. Another list of questions will then beckon. Do these new particles really have the correct properties to be the dark matter? Do they account for all of the dark matter, or only part of it? What do their properties tell us about the evolut

  6. Subseabed disposal program annual report, January-December 1980. Volume II. Appendices (principal investigator progress reports). Part 1

    SciTech Connect (OSTI)

    Hinga, K.R. (ed.) ed.

    1981-07-01T23:59:59.000Z

    Volume II of the sixth annual report describing the progress and evaluating the status of the Subseabed Disposal Program contains the appendices referred to in Volume I, Summary and Status. Because of the length of Volume II, it has been split into two parts for publication purposes. Part 1 contains Appendices A-Q; Part 2 contains Appendices R-MM. Separate abstracts have been prepared for each appendix for inclusion in the Energy Data Base.

  7. 1995 Solid Waste 30-year volume summary

    SciTech Connect (OSTI)

    Valero, O.J. [Westinghouse Hanford Co., Richland, WA (United States); DeForest, T.J.; Templeton, K.J. [Pacific Northwest Lab., Richland, WA (United States)

    1995-06-01T23:59:59.000Z

    This document, prepared by Pacific Northwest Laboratory (PNL) under the direction of Westinghouse Hanford Company (WHC), provides a description of the annual low-level mixed waste (LLMW) and transuranic/transuranic mixed solid waste (TRU-TRUM) volumes expected to be managed by Hanford`s Solid Waste Central Waste Complex (CWC) over the next 30 years. The waste generation sources and waste categories are also described. This document is intended to be used as a reference for short- and long-term planning of the Hanford treatment, storage, and disposal (TSD) activities over the next several decades. By estimating the waste volumes that will be generated in the future, facility planners can determine the timing of key waste management activities, evaluate alternative treatment strategies, and plan storage and disposal capacities. In addition, this document can be used by other waste sites and the general public to gain a better understanding of the types and volumes of waste that will be managed at Hanford.

  8. Cambridge, Massachusetts Reference: 90246.00

    E-Print Network [OSTI]

    a barrier than an enabler to all these technologies because of problems with: ­ Weight &volume ­ Energy useH2 compression and storage scheme incorporates primary compressors, intermediate pressure storage Hydraulic Fluid Storage Hydraulic Pump 3-4 Stage Compressor (with intercooling) Accumulator 1 Accumulator 2

  9. Effect of Lumpectomy Cavity Volume Change on the Clinical Target Volume for Accelerated Partial Breast Irradiation: A Deformable Registration Study

    SciTech Connect (OSTI)

    Kim, Leonard H., E-mail: lkim@beaumonthospitals.co [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States); DeCesare, Sam; Vicini, Frank; Yan Di [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)

    2010-11-15T23:59:59.000Z

    Purpose: Previous studies have shown that lumpectomy cavity volumes can change significantly in the weeks following surgery. The effect of this volume change on the surrounding tissue that constitutes the clinical target volume (CTV) for accelerated partial breast irradiation and boost treatment after whole breast irradiation has not been previously studied. In the present study, we used deformable registration to estimate the effect of lumpectomy cavity volume changes on the CTV for accelerated partial breast irradiation and discuss the implications for target construction. Methods and Materials: The data from 13 accelerated partial breast irradiation patients were retrospectively analyzed. Deformable registration was used to propagate contours from the initial planning computed tomography scan to a later computed tomography scan acquired at the start of treatment. The changes in cavity volume and CTV, distance between cavity and CTV contours (i.e., CTV margin), and CTV localization error after cavity registration were determined. Results: The mean {+-} standard deviation change in cavity volume and CTV between the two computed tomography scans was -35% {+-} 23% and -14% {+-} 12%, respectively. An increase in the cavity-to-CTV margin of 2 {+-} 2 mm was required to encompass the CTV, and this increase correlated with the cavity volume change. Because changes in the cavity and CTV were not identical, a localization error of 2-3 mm in the CTV center of mass occurred when the cavity was used as the reference for image guidance. Conclusion: Deformable registration suggested that CTV margins do not remain constant as the cavity volume changes. This finding has implications for planning target volume and CTV construction.

  10. Collected References, available on-line as , updated 23-Feb-14 References for: Gio Wiederhold

    E-Print Network [OSTI]

    Stanford University

    .6] [Abba:97] Wayne Abba: "Earned Value Management: Reconciling Government and Commercial Practices-14 1 References for: Gio Wiederhold: Valuing Intellectual Capital, Multinationals and Taxhavens is italicized. Entries cited and listed in the Reference section of Valuing Intelectual Capital have [bold

  11. NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties--

    E-Print Network [OSTI]

    Magee, Joseph W.

    -Conditioning and Refrigeration Technology Institute and the U.S. Department of Energy. The development of the models on which#12;NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties Properties Division National Institute of Standards and Technology Boulder, Colorado 80305 April, 2007 U

  12. NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties--

    E-Print Network [OSTI]

    Technology Institute and the U.S. Department of Energy. Model development and measurements at NIST have been#12;NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties Division National Institute of Standards and Technology Boulder, Colorado 80305 November, 2010 U

  13. Kyoto University Libraries Reference Guide 1. Compare the reference style of books and journals

    E-Print Network [OSTI]

    Takada, Shoji

    Kyoto University Libraries Reference Guide 1. Compare the reference style of books and journals Ex Publisher Year of Publications Pages Ex.3) The basic style of journal articles Fidel, Raya; Green, Maurice -Distinguishing kinds of documents- Ver.1.1, 2008.03.26, Yumi Sugimoto (Eng.Arch.Library), Ver.2.0, 2014

  14. Publications Edited Volume

    E-Print Network [OSTI]

    MacIver, Malcolm A.

    of Robots with Passive Environments: Application to Force Feedback Control Ed Colgate and Neville Hogan, J. Edward Colgate Industrial Robot, 26 (5), 1999, pp 335-341 Toward Robot-Assisted VascularPublications Edited Volume Advances in Robotics, Mechatronics, and Haptic Interfaces 1993 Edited

  15. INVESTIGATION Construction of Reference Chromosome-Scale

    E-Print Network [OSTI]

    Douches, David S.

    INVESTIGATION Construction of Reference Chromosome-Scale Pseudomolecules for Potato: Integrating was genotyped with several types of molecular genetic markers to construct a new ~936 cM linkage map comprising and orientation within the pseudo- molecules are closely collinear with independently constructed high density

  16. Risk Management Steering Committee Terms of Reference

    E-Print Network [OSTI]

    Victoria, University of

    Risk Management Steering Committee Terms of Reference October 2009 1.0 Purpose The purposes Facilities Management Risk and Insurance Analyst Associate Vice-President Human Resources Administrative of the Steering Committee are: a) to follow a continuous process to understand and communicate risk from

  17. Previous Up Next Article From References: 0

    E-Print Network [OSTI]

    Stachó, László

    Previous Up Next Article Citations From References: 0 From Reviews: 0 MR1261496 (94k:49008) 49J35 of f on X × co(Y ). Here, co(Y ) is a certain simplex defined in the space of all real-valued functions

  18. Previous Up Next Article From References: 12

    E-Print Network [OSTI]

    Ghys, Étienne

    Previous Up Next Article Citations From References: 12 From Reviews: 3 MR939473 (89e:55015) 55N35(M, R) is the cohomology of singular cochains whose value on a singular simplex is bounded independent of the simplex. From the work of Gromov, one knows that bounded cohomology interacts in a delicate manner

  19. Positional reference system for ultraprecision machining

    DOE Patents [OSTI]

    Arnold, Jones B. (Knoxville, TN); Burleson, Robert R. (Clinton, TN); Pardue, Robert M. (Knoxville, TN)

    1982-01-01T23:59:59.000Z

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of position interferometers and part contour description data inputs to calculate error components for each axis of movement and output them to corresponding axis drives with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  20. Positional reference system for ultraprecision machining

    DOE Patents [OSTI]

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12T23:59:59.000Z

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  1. REFERENCE GUIDE ENERGY CONSERVATION ASSISTANCE ACT (ECAA)

    E-Print Network [OSTI]

    with this requirement. Waste management guidance and plan template can be downloaded at http://www.energy that generate waste. Attachments: Energy Commission Waste Management Plan Guidance Waste Management Plan1 REFERENCE GUIDE ENERGY CONSERVATION ASSISTANCE ACT (ECAA) STATE ENERGY PROGRAM (SEP) AMERICAN

  2. Ris Energy Report 2 References chapter 3

    E-Print Network [OSTI]

    8 Risø Energy Report 2 References chapter 3 1. IEA (2001), World Energy Outlook, OECD/IEA 2001. 2, Rome. 3. UNDP (2000): World Energy Assessment, NY 2000. 4. WEC (2001): Survey of energy resources. World Energy Council, Lon- don. 5. Kaltschmitt (2001): Martin Kaltschmitt, Hans Hartmann (Hrsg

  3. Hazard Communication Program 1.0 REFERENCE

    E-Print Network [OSTI]

    de Lijser, Peter

    Hazard Communication Program 1.0 REFERENCE California Code of Regulations, Title 8, Sections 337 the properties and potential safety and health hazards of the materials which they use or to which they are exposed. Employees who use or may be exposed to potentially hazardous substances or harmful physical

  4. FOR OFFICE USE ONLY Referred to

    E-Print Network [OSTI]

    Wang, Xiaorui "Ray"

    : In Partial Fulfillment of the requirements of the degree of: in: REVIEW AND ACCEPTANCE - REQUIRED SIGNATURESFOR OFFICE USE ONLY Month/Year Graduation Referred to Approved Denied GRADUATE SCHOOL THESIS of this thesis or dissertation. EMBARGO REQUEST Instructions: Student may request a one-year embargo

  5. Terms of Reference Information Security Group

    E-Print Network [OSTI]

    Haase, Markus

    Terms of Reference Information Security Group Version 3.1 8 March 2011 © University of Leeds 2011 Security Group Information Security Management 3.1 (8/3/11) Page 2 of 4 Document Control Owner: Kevin Darley, IT Security Co-ordinator, Information Systems Services, University of Leeds Source Location: V

  6. Geoscience laser altimeter system - stellar reference system

    SciTech Connect (OSTI)

    Millar, Pamela S.; Sirota, J. Marcos [NASA Goddard Space Flight Center, Laser Remote Sensing Branch, Code 924, Greenbelt, Maryland, 20771 (United States); University of Maryland at Baltimore County, 5401 Wilkens Ave, Baltimore, Maryland, 21228-5398 (United States)

    1998-01-15T23:59:59.000Z

    GLAS is an EOS space-based laser altimeter being developed to profile the height of the Earth's ice sheets with {approx}15 cm single shot accuracy from space under NASA's Mission to Planet Earth (MTPE). The primary science goal of GLAS is to determine if the ice sheets are increasing or diminishing for climate change modeling. This is achieved by measuring the ice sheet heights over Greenland and Antarctica to 1.5 cm/yr over 100 kmx100 km areas by crossover analysis (Zwally 1994). This measurement performance requires the instrument to determine the pointing of the laser beam to {approx}5 urad (1 arcsecond), 1-sigma, with respect to the inertial reference frame. The GLAS design incorporates a stellar reference system (SRS) to relate the laser beam pointing angle to the star field with this accuracy. This is the first time a spaceborne laser altimeter is measuring pointing to such high accuracy. The design for the stellar reference system combines an attitude determination system (ADS) with a laser reference system (LRS) to meet this requirement. The SRS approach and expected performance are described in this paper.

  7. Run-Time Library Routines Reference

    E-Print Network [OSTI]

    California at San Diego, University of

    MDS Run-Time Library Routines Reference Manual February 1993 Software Version: MDS 5.2 VAX.S.A. The following are trademarks of Digitial Equipment Corporation: CDD DECnet VAX DATATRIEVE DECUS VAXcluster DEC MicroVAX VAX Information Architecture DEC/CMS MicroVMS VMS DEC/MMS Rdb/VMS VT IDL (Interactive Data

  8. R Reference Manual: A gentle overview

    E-Print Network [OSTI]

    Priestley, Jennifer Lewis

    , yet similar to SAS, R is a commands-driven programming environment to execute statistical analysisR Reference Manual: A gentle overview #12;2 Developed and maintained by the Center for Statistics statistical computing packages ­ Excel, SPSS, Minitab, R and SAS. 1 Readers of this manual are assumed to have

  9. SENATE COMMITTEE ON AWARDS TERMS OF REFERENCE

    E-Print Network [OSTI]

    Victoria, University of

    SENATE COMMITTEE ON AWARDS TERMS OF REFERENCE The committee shall: 1. Approve and recommend to Senate new or revised undergraduate and graduate student awards and the terms and conditions for those awards; 2. Consider and approve the student recipients nominated or recommended for undergraduate awards

  10. Xyce parallel electronic simulator : reference guide.

    SciTech Connect (OSTI)

    Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Warrender, Christina E.; Keiter, Eric Richard; Pawlowski, Roger Patrick

    2011-05-01T23:59:59.000Z

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains comprehensive, detailed information about a number of topics pertinent to the usage of Xyce. Included in this document is a netlist reference for the input-file commands and elements supported within Xyce; a command line reference, which describes the available command line arguments for Xyce; and quick-references for users of other circuit codes, such as Orcad's PSpice and Sandia's ChileSPICE.

  11. Reference number ISO 8601:2004(E)

    E-Print Network [OSTI]

    Wu, Shiliang

    Reference number ISO 8601:2004(E) © ISO 2004 INTERNATIONAL STANDARD ISO 8601 Third edition 2004'heure #12;ISO 8601:2004(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems

  12. Documents and Briefcase Zimbra Quick Reference Card

    E-Print Network [OSTI]

    Portman, Douglas

    Documents and Briefcase Zimbra Quick Reference Card Documents ­ Workspace (http://z.rochester.edu) Documents Shortcuts Edit Refresh Show Shortcuts + Cancel Save + Go the `Shortcuts' tab on the left. Basic Briefcase Tasks What is Briefcase? It is a tool for managing files from

  13. FORM FOR ESPC CASE STUDIES AND REFERENCES | Department of Energy

    Office of Environmental Management (EM)

    FORM FOR ESPC CASE STUDIES AND REFERENCES FORM FOR ESPC CASE STUDIES AND REFERENCES Document features a template, sample, and instructions to help Federal agencies develop case...

  14. asce standardized reference: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lux (of 26 INSTALLATION AND UNCERTAINTY EVALUATION OF REFERENCE HARDNESS STANDARD OF CROATIA CiteSeer Summary: Abstract ? Reference hardness standard with HV1 HV50 measuring...

  15. analytical reference standards: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Lux (of 27 INSTALLATION AND UNCERTAINTY EVALUATION OF REFERENCE HARDNESS STANDARD OF CROATIA CiteSeer Summary: Abstract ? Reference hardness standard with HV1 HV50 measuring...

  16. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reference Buildings by Climate Zone and Representative City: 4B Albuquerque, New Mexico Reference Buildings by Climate Zone and Representative City: 4B Albuquerque, New...

  17. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Reference Buildings by Climate Zone and Representative City: 5B Boulder, Colorado Reference Buildings by Climate Zone and Representative...

  18. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Reference Buildings by Climate Zone and Representative City: 4C Seattle, Washington Reference Buildings by Climate Zone and Representative...

  19. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Reference Buildings by Climate Zone and Representative City: 6B Helena, Montana Reference Buildings by Climate Zone and Representative...

  20. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Reference Buildings by Climate Zone and Representative City: 8 Fairbanks, Alaska Reference Buildings by Climate Zone and Representative...

  1. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Reference Buildings by Climate Zone and Representative City: 5A Chicago, Illinois Reference Buildings by Climate Zone and Representative...

  2. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Reference Buildings by Climate Zone and Representative City: 3B Las Vegas, Nevada Reference Buildings by Climate Zone and Representative...

  3. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications Reference Buildings by Climate Zone and Representative City: 4A Baltimore, Maryland Reference Buildings by Climate Zone and Representative...

  4. Reference Buildings by Climate Zone and Representative City:...

    Broader source: Energy.gov (indexed) [DOE]

    akfairbankspre1980v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 8 Fairbanks, Alaska Reference Buildings by Climate Zone...

  5. Reference Buildings by Climate Zone and Representative City:...

    Broader source: Energy.gov (indexed) [DOE]

    minneapolispre1980v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 6A Minneapolis, Minnesota Reference Buildings by...

  6. Topology-controlled volume rendering

    E-Print Network [OSTI]

    Weber, Gunther H; Dillard, Scott E; Carr, Hamish; Pascucci, Valerio; Hamann, Bernd

    2007-01-01T23:59:59.000Z

    type. Even when volume render- ing is applied to nonmedicalin graphics hardware. We render tubes between saddles and

  7. Ponnequin Wind Energy Project: Reference site avian study, January 1, 1998--December 31, 1998

    SciTech Connect (OSTI)

    Kerlinger, P.; Curry, R.; Ryder, R.

    2000-04-05T23:59:59.000Z

    This report summarizes the results of surveys completed during the period January 1, 1998, through December 31, 1998, at the Ponnequin Wind Energy Project in Weld County, Colorado. The surveys were conducted at two reference sites, and include a pre-construction avian abundance and use survey and raptor nesting, prey, and carcass surveys. The reference sites were situated immediately to the west of the project site in Weld County, Colorado, and 4.8 kilometers to the north of the site in Laramie County, Wyoming. The surveys were conducted along two 800-meter (m) main transects at each site with two 400-m (by 100-m) perpendicular transects. About 30 complete surveys were completed during the year, with a greater frequency of surveys in the late spring and early autumn. The surveys revealed mostly common species, with no endangered or threatened species on the sites. Small numbers of raptors were observed on or near the project and reference areas. During the winter, avian use and abundance was minimal. Prey species consisted primarily of thirteen-lined ground squirrels and northern pocket gophers. Two songbird carcasses were found. The results of these surveys, combined with data from several more months of surveys, will be compared to surveys conducted after construction of the wind farm.

  8. Site Environmental Report for 2011, Volumes 1& 2

    SciTech Connect (OSTI)

    Baskin, David; Bauters, Tim; Borglin, Ned; Fox, Robert; Horst, Blair; Jelinski, John; Lackner, Ginny; Philliber, Jeff; Rothermich, Nancy; Thorson, Patrick; Wahl, Linnea; Xu, Suying

    2012-09-12T23:59:59.000Z

    The Site Environmental Report for 2011 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year (CY) 2011. Throughout this report, “Berkeley Lab” or “LBNL” refers both to (1) the multiprogram scientific facility the UC manages and operates on the 202-acre university-owned site located in the hills above the UC Berkeley campus, and the site itself, and (2) the UC as managing and operating contractor for Ernest Orlando Lawrence Berkeley National Laboratory. The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that include an overview of LBNL, a discussion of its Environmental Management System (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities.

  9. Revised Analyses of Decommissioning Reference Non-Fuel-Cycle Facilities

    SciTech Connect (OSTI)

    MC Bierschbach; DR Haffner; KJ Schneider; SM Short

    2002-12-01T23:59:59.000Z

    Cost information is developed for the conceptual decommissioning of non-fuel-cycle nuclear facilities that represent a significant decommissioning task in terms of decontamination and disposal activities. This study is a re-evaluation of the original study (NUREG/CR-1754 and NUREG/CR-1754, Addendum 1). The reference facilities examined in this study are the same as in the original study and include: a laboratory for the manufacture of {sup 3}H-labeled compounds; a laboratory for the manufacture of {sup 14}C-labeled compounds; a laboratory for the manufacture of {sup 123}I-labeled compounds; a laboratory for the manufacture of {sup 137}Cs sealed sources; a laboratory for the manufacture of {sup 241}Am sealed sources; and an institutional user laboratory. In addition to the laboratories, three reference sites that require some decommissioning effort were also examined. These sites are: (1) a site with a contaminated drain line and hold-up tank; (2) a site with a contaminated ground surface; and (3) a tailings pile containing uranium and thorium residues. Decommissioning of these reference facilities and sites can be accomplished using techniques and equipment that are in common industrial use. Essentially the same technology assumed in the original study is used in this study. For the reference laboratory-type facilities, the study approach is to first evaluate the decommissioning of individual components (e.g., fume hoods, glove boxes, and building surfaces) that are common to many laboratory facilities. The information obtained from analyzing the individual components of each facility are then used to determine the cost, manpower requirements and dose information for the decommissioning of the entire facility. DECON, the objective of the 1988 Rulemaking for materials facilities, is the decommissioning alternative evaluated for the reference laboratories because it results in the release of the facility for restricted or unrestricted use as soon as possible. For a facility, DECON requires that contaminated components either be: (1) decontaminated to restricted or unrestricted release levels or (2) packaged and shipped to an authorized disposal site. This study considers unrestricted release only. The new decommissioning criteria of July 1997 are too recent for this study to include a cost analysis of the restricted release option, which is now allowed under these new criteria. The costs of decommissioning facility components are generally estimated to be in the range of $140 to $27,000, depending on the type of component, the type and amount of radioactive contamination, the remediation options chosen, and the quantity of radioactive waste generated from decommissioning operations. Estimated costs for decommissioning the example laboratories range from $130,000 to $205,000, assuming aggressive low-level waste (LLW) volume reduction. If only minimal LLW volume reduction is employed, decommissioning costs range from $150,000 to $270,000 for these laboratories. On the basis of estimated decommissioning costs for facility components, the costs of decommissioning typical non-fuel-cycle laboratory facilities are estimated to range from about $25,000 for the decommissioning of a small room containing one or two fume hoods to more than $1 million for the decommissioning of an industrial plant containing several laboratories in which radiochemicals and sealed radioactive sources are prepared. For the reference sites of this study, the basic decommissioning alternatives are: (1) site stabilization followed by long-term care and (2) removal of the waste or contaminated soil to an authorized disposal site. Cost estimates made for decommissioning three reference sites range from about $130,000 for the removal of a contaminated drain line and hold-up tank to more than $23 million for the removal of a tailings pile that contains radioactive residue from ore-processing operations in which tin slag is processed for the recovery of rare metals. Total occupational radiation doses generally range from 0.00007 person-rem to 13 person-rem for

  10. High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation

    E-Print Network [OSTI]

    High Volume Test Automation 1 High Volume Test AutomationHigh Volume Test Automation Keynote Automation 2 AcknowledgementsAcknowledgements · Many of the ideas in this presentation were initially jointly developed with Doug Hoffman,as we developed a course on test automation architecture, and in the Los Altos

  11. Reference Inside KS1992 Tray Inside Air

    E-Print Network [OSTI]

    Llope, William J.

    Reference Inside KS1992 0.2 Tray Inside Air 0.5 Tray Inside Air 0.8 Tray Inside Air 0.2 Tray Side Wall Inner 0.2 Tray Side Wall Inner Under TAMP near sensor pos4 Under TAMP near sensor pos4 Air Gap Below TDIG pos1 Air Gap Below TDIG pos4 Air Gap Below TDIG pos6 HPTDC1 Chip pos6 HPTDC4 Chip pos6 HPTDC2

  12. Annual review of energy, Volume 13

    SciTech Connect (OSTI)

    Hollander, J.M.; Brooks, H.; Sternlight, D. (eds.)

    1988-01-01T23:59:59.000Z

    A current optimism exists about energy today. This optimism is in contrast to the decade from the mid-1970s to the mid-1980s when the price of energy spiraled and there was an increasing awareness of the environmental risks and impacts of energy use. This series of energy articles chronicles important advances in the technologies of energy supply and use, describes the state of understanding energy use throughout the world, and reviews the risks and uncertainties associated with energy systems and choices. Qualified authors present critical articles with references. Topics discussed in this thirteenth volume of the series include house air-to-air heat-exchanger, electricity transmission, third world residential energy, the accident at Chernobyl, recycling and proliferation, and nuclear waste policy conflicts.

  13. Site Environmental Report for 2009, Volume I

    SciTech Connect (OSTI)

    Lackner, Regina

    2010-08-17T23:59:59.000Z

    Each year, the University of California (UC), as the managing and operating contractor of the Ernest Orlando Lawrence Berkeley National Laboratory, prepares an integrated report regarding its environmental programs to satisfy the requirements of United States Department of Energy (DOE) Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2009 summarizes Berkeley Lab's environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year (CY) 2009. Throughout this report, 'Berkeley Lab' or 'LBNL' refers both to (1) the multiprogram scientific facility the UC manages and operates on the 202-acre university-owned site located in the hills above the UC Berkeley campus, and the site itself, and (2) the UC as managing and operating contractor for Ernest Orlando Lawrence Berkeley National Laboratory. The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that contain an overview of LBNL, a discussion of its environmental management system (EMS), the status of environmental programs, summarized results from surveillance and monitoring activities, and quality assurance (QA) measures. Volume II contains individual data results from surveillance and monitoring activities. The Site Environmental Report is distributed by releasing it on the World Wide Web (Web) from the Berkeley Lab Environmental Services Group (ESG) home page, which is located at www.lbl.gov/ehs/esg/. Many of the documents cited in this report also are accessible from the ESG Web page. Links to documents available on the Web are given with the citations in the References section. CD and printed copies of this Site Environmental Report are available upon request. The report follows Berkeley Lab's policy of using the International System of Units (SI), also known as the metric system of measurements. Whenever possible, results are also reported using the more conventional (non-SI) system of measurements, because the non-SI system is referenced by several current regulatory standards and is more familiar to some readers. Two tables are provided at the end of the Glossary to help readers: Table G-1 defines the prefixes used with SI units of measurement, and Table G-2 provides conversions to non-SI units. Years mentioned in this report refer to calendar years unless specified as fiscal year(s). Berkeley Lab's fiscal year (FY) is October 1 to September 30, and begins in the year previous to its name, i.e., FY 2009 was from October 1, 2008, to September 30, 2009. For ease of reference, a key to acronyms and abbreviations used in this report can be found directly after the text, at the end of Chapter 6. Following that is also a glossary for readers who may be unfamiliar with some of the terms used in this report. This report was prepared under the direction of Ron Pauer of ESG. Please address any questions regarding this report to him by telephone at 510-486-7614, or by e-mail at ropauer@lbl.gov. The primary contributors were David Baskin, Tim Bauters, Ned Borglin, Robert Fox, John Jelinski, Ginny Lackner, Patrick Thorson, Linnea Wahl, and Suying Xu (Volume II). Readers are encouraged to comment on this report by completing the survey form found at the ESG Web page where this report is available.

  14. Technology, Safety and Costs of Decommissioning a Reference Low-Level Waste Burial Ground. Main Report

    SciTech Connect (OSTI)

    Murphy, E. S.; Holter, G. M.

    1980-06-01T23:59:59.000Z

    Safety and cost information are developed for the conceptual decommissioning of commercial low-level waste (LLW) burial grounds. Two generic burial grounds, one located on an arid western site and the other located on a humid eastern site, are used as reference facilities for the study. The two burial grounds are assumed to have the same site capacity for waste, the same radioactive waste inventory, and similar trench characteristics and operating procedures. The climate, geology. and hydrology of the two sites are chosen to be typical of real western and eastern sites. Volume 1 (Main Report) contains background information and study results in summary form.

  15. Reference samples for water-related programs in the US Environmental Protection Agency

    SciTech Connect (OSTI)

    Winter, J.A.

    1985-06-01T23:59:59.000Z

    The Environmental Monitoring and Support Laboratory at Cincinnati provides quality assurance (QA) support for US Environmental Protection Agency (EPA) water-related programs. Two important segments of this support are the Quality Control Sample Program, which furnishes samples of known concentrations for use as independent checks on intralaboratory QA activities, and the EPA's Repository for Toxic and Hazardous Materials, which provides calibration standards and spiking solutions for trace organic analyses of interest to the Agency. Each series contains one or more analytes, with true or reference values. The samples and standards are prepared as stable concentrated solutions in all-glass ampuls for dilution to volume, and analyses by EPA, its contractors and grantees, and other federal, state, and local agencies. 1 reference, 6 tables.

  16. Modcomp MAX IV System Processors reference guide

    SciTech Connect (OSTI)

    Cummings, J.

    1990-10-01T23:59:59.000Z

    A user almost always faces a big problem when having to learn to use a new computer system. The information necessary to use the system is often scattered throughout many different manuals. The user also faces the problem of extracting the information really needed from each manual. Very few computer vendors supply a single Users Guide or even a manual to help the new user locate the necessary manuals. Modcomp is no exception to this, Modcomp MAX IV requires that the user be familiar with the system file usage which adds to the problem. At General Atomics there is an ever increasing need for new users to learn how to use the Modcomp computers. This paper was written to provide a condensed Users Reference Guide'' for Modcomp computer users. This manual should be of value not only to new users but any users that are not Modcomp computer systems experts. This Users Reference Guide'' is intended to provided the basic information for the use of the various Modcomp System Processors necessary to, create, compile, link-edit, and catalog a program. Only the information necessary to provide the user with a basic understanding of the Systems Processors is included. This document provides enough information for the majority of programmers to use the Modcomp computers without having to refer to any other manuals. A lot of emphasis has been placed on the file description and usage for each of the System Processors. This allows the user to understand how Modcomp MAX IV does things rather than just learning the system commands.

  17. Report: An Updated Annual Energy Outlook 2009 Reference Case...

    U.S. Energy Information Administration (EIA) Indexed Site

    industrial sectors used primarily for own-use generation, but which may also sell some power to the grid." " 8 Includes refinery gas and still gas." " 9 Includes conventional...

  18. Department of Energy Construction Safety Reference Guide

    SciTech Connect (OSTI)

    Not Available

    1993-09-01T23:59:59.000Z

    DOE has adopted the Occupational Safety and Health Administration (OSHA) regulations Title 29 Code of Federal Regulations (CFR) 1926 ``Safety and Health Regulations for Construction,`` and related parts of 29 CFR 1910, ``Occupational Safety and Health Standards.`` This nonmandatory reference guide is based on these OSHA regulations and, where appropriate, incorporates additional standards, codes, directives, and work practices that are recognized and accepted by DOE and the construction industry. It covers excavation, scaffolding, electricity, fire, signs/barricades, cranes/hoists/conveyors, hand and power tools, concrete/masonry, stairways/ladders, welding/cutting, motor vehicles/mechanical equipment, demolition, materials, blasting, steel erection, etc.

  19. AVIATION MANAGER QUALIFICATION STANDARD REFERENCE GUIDE

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy China 2015ofDepartmentDepartment of2 of 5) ALARAManager Qualification Standard Reference

  20. References - DOE Directives, Delegations, and Requirements

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItemResearch > TheNuclear Press Releases 2014References by Website Administrator This

  1. Sandia Energy - Marine Hydrokinetics Technology: Reference Model

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Scienceand RequirementsCoatingsUltra-High-VoltagePowerUpdatesDevelopment Reference Model

  2. 2014 Manufacturing Energy and Carbon Footprints: References

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of BadTHEEnergy VehicleSessionOffice |OfficeAboutofAugustReferences

  3. Template:Reference | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty Edit with formSoutheastern ILSunseekerTallahatchieTecniplanReference Jump to:

  4. Commercial Reference Buildings | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model, clickInformationNew York:Governor s(RedirectedColusaCommack,Reference

  5. Lokaratna, Volume 4

    E-Print Network [OSTI]

    Mishra, Mahendra Kumar

    2011-01-01T23:59:59.000Z

    Muthukumarswamy and his colleagues of NFSC, Chennai to support this volume to be published in their web site for a global readership. On behalf of Folklore Foundation, Odisha Bhubaneswar , I wish a Happy and prosperous new Year 2012... (b)ali-B?eli,5 mythical Great Ancestress of the Kondhs and, at one time, a human manifestation of the earth goddess ? originally choose to manifest herself to man in her tiger form; after she had assumed such form, she killed a large quantity of game animals...

  6. FY 2005 Volume 4

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic Plan| Department of.pdf6-OPAMDepartment of EnergyME-0035 Volume 4 Science

  7. FY 2005 Volume 5

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic Plan| Department of.pdf6-OPAMDepartment of EnergyME-0035 Volume 4 Science6

  8. FY 2005 Volume 6

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic Plan| Department of.pdf6-OPAMDepartment of EnergyME-0035 Volume 4 Science67

  9. FY 2005 Volume 7

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic Plan| Department of.pdf6-OPAMDepartment of EnergyME-0035 Volume 4

  10. Volume One Disc Two

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps1 -Visualizing Brain Metals inVolume-One-Disc-Two

  11. Reference worldwide model for antineutrinos from reactors

    E-Print Network [OSTI]

    Marica Baldoncini; Ivan Callegari; Giovanni Fiorentini; Fabio Mantovani; Barbara Ricci; Virginia Strati; Gerti Xhixha

    2015-02-16T23:59:59.000Z

    Antineutrinos produced at nuclear reactors constitute a severe source of background for the detection of geoneutrinos, which bring to the Earth's surface information about natural radioactivity in the whole planet. In this framework we provide a reference worldwide model for antineutrinos from reactors, in view of reactors operational records yearly published by the International Atomic Energy Agency (IAEA). We evaluate the expected signal from commercial reactors for ongoing (KamLAND and Borexino), planned (SNO+) and proposed (Juno, RENO-50, LENA and Hanohano) experimental sites. Uncertainties related to reactor antineutrino production, propagation and detection processes are estimated using a Monte Carlo based approach, which provides an overall site dependent uncertainty on the signal in the geoneutrino energy window on the order of 3%. We also implement the off-equilibrium correction to the reference reactor spectra associated with the long-lived isotopes and we estimate a 2.4% increase of the unoscillated event rate in the geoneutrino energy window due to the storage of spent nuclear fuels in the cooling pools. We predict that the research reactors contribute to less than 0.2% to the commercial reactor signal in the investigated 14 sites. We perform a multitemporal analysis of the expected reactor signal over a time lapse of 10 years using reactor operational records collected in a comprehensive database published at www.fe.infn.it/antineutrino.

  12. Generic Argillite/Shale Disposal Reference Case

    SciTech Connect (OSTI)

    Zheng, Liange; Colon, Carlos Jové; Bianchi, Marco; Birkholzer, Jens

    2014-08-08T23:59:59.000Z

    Radioactive waste disposal in a deep subsurface repository hosted in clay/shale/argillite is a subject of widespread interest given the desirable isolation properties, geochemically reduced conditions, and widespread geologic occurrence of this rock type (Hansen 2010; Bianchi et al. 2013). Bianchi et al. (2013) provides a description of diffusion in a clay-hosted repository based on single-phase flow and full saturation using parametric data from documented studies in Europe (e.g., ANDRA 2005). The predominance of diffusive transport and sorption phenomena in this clay media are key attributes to impede radionuclide mobility making clay rock formations target sites for disposal of high-level radioactive waste. The reports by Hansen et al. (2010) and those from numerous studies in clay-hosted underground research laboratories (URLs) in Belgium, France and Switzerland outline the extensive scientific knowledge obtained to assess long-term clay/shale/argillite repository isolation performance of nuclear waste. In the past several years under the UFDC, various kinds of models have been developed for argillite repository to demonstrate the model capability, understand the spatial and temporal alteration of the repository, and evaluate different scenarios. These models include the coupled Thermal-Hydrological-Mechanical (THM) and Thermal-Hydrological-Mechanical-Chemical (THMC) models (e.g. Liu et al. 2013; Rutqvist et al. 2014a, Zheng et al. 2014a) that focus on THMC processes in the Engineered Barrier System (EBS) bentonite and argillite host hock, the large scale hydrogeologic model (Bianchi et al. 2014) that investigates the hydraulic connection between an emplacement drift and surrounding hydrogeological units, and Disposal Systems Evaluation Framework (DSEF) models (Greenberg et al. 2013) that evaluate thermal evolution in the host rock approximated as a thermal conduction process to facilitate the analysis of design options. However, the assumptions and the properties (parameters) used in these models are different, which not only make inter-model comparisons difficult, but also compromise the applicability of the lessons learned from one model to another model. The establishment of a reference case would therefore be helpful to set up a baseline for model development. A generic salt repository reference case was developed in Freeze et al. (2013) and the generic argillite repository reference case is presented in this report. The definition of a reference case requires the characterization of the waste inventory, waste form, waste package, repository layout, EBS backfill, host rock, and biosphere. This report mainly documents the processes in EBS bentonite and host rock that are potentially important for performance assessment and properties that are needed to describe these processes, with brief description other components such as waste inventory, waste form, waste package, repository layout, aquifer, and biosphere. A thorough description of the generic argillite repository reference case will be given in Jové Colon et al. (2014).

  13. Nuclear power plant simulation facility evaluation methodology: handbook. Volume 1

    SciTech Connect (OSTI)

    Laughery, K.R. Jr.; Carter, R.J.; Haas, P.M.

    1986-01-01T23:59:59.000Z

    This report is Volume 1 of a two-part document which describes a project conducted to develop a methodology to evaluate the acceptability of nuclear power plant (NPP) simulation facilities for use in the simulator-based portion of NRC's operator licensing examination. The proposed methodology is to be utilized during two phases of the simulation facility life-cycle, initial simulator acceptance and recurrent analysis. The first phase is aimed at ensuring that the simulator provides an accurate representation of the reference NPP. There are two components of initial simulator evaluation: fidelity assessment and a direct determination of the simulation facility's adequacy for operator testing. The second phase is aimed at ensuring that the simulation facility continues to accurately represent the reference plant throughout the life of the simulator. Recurrent evaluation is comprised of three components: monitoring reference plant changes, monitoring the simulator's hardware, and examining the data from actual plant transients as they occur. Volume 1 is a set of guidelines which details the steps involved in the two life-cycle phases, presents an overview of the methodology and data collection requirements, and addresses the formation of the evaluation team and the preparation of the evaluation plan. 29 figs.

  14. WECC Variable Generation Planning Reference Book

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-14T23:59:59.000Z

    This planning reference book is a document reflecting a Western Electricity Coordination Council (WECC) effort to put together multiple sources of information and provide a clear, systemic, comprehensive outline of the problems, both existing and anticipated; their impacts on the system; currently used and proposed solutions by the industry and research community; planning practices; new technologies, equipment, and standards; and expected future trends. This living (periodically updated) document could help WECC and other practicing engineers, especially the younger generation of engineers joining the workforce, to get familiar with a large variety of information related to the integration of variable resources into the WECC system, bypassing in part the need for time-consuming information gathering and learning processes from more experienced engineers or from the literature.

  15. Semantic Features for Classifying Referring Search Terms

    SciTech Connect (OSTI)

    May, Chandler J.; Henry, Michael J.; McGrath, Liam R.; Bell, Eric B.; Marshall, Eric J.; Gregory, Michelle L.

    2012-05-11T23:59:59.000Z

    When an internet user clicks on a result in a search engine, a request is submitted to the destination web server that includes a referrer field containing the search terms given by the user. Using this information, website owners can analyze the search terms leading to their websites to better understand their visitors needs. This work explores some of the features that can be used for classification-based analysis of such referring search terms. We present initial results for the example task of classifying HTTP requests countries of origin. A system that can accurately predict the country of origin from query text may be a valuable complement to IP lookup methods which are susceptible to the obfuscation of dereferrers or proxies. We suggest that the addition of semantic features improves classifier performance in this example application. We begin by looking at related work and presenting our approach. After describing initial experiments and results, we discuss paths forward for this work.

  16. ACAA fly ash basics: quick reference card

    SciTech Connect (OSTI)

    NONE

    2006-07-01T23:59:59.000Z

    Fly ash is a fine powdery material created when coal is burned to generate electricity. Before escaping into the environment via the utility stacks, the ash is collected and may be stored for beneficial uses or disposed of, if necessary. The use of fly ash provides environmental benefits, such as the conservation of natural resources, the reduction of greenhouse gas emissions and eliminating the needed for ash disposal in landfills. It is also a valuable mineral resource that is used in construction and manufacturing. Fly ash is used in the production of Portland cement, concrete, mortars and stuccos, manufactured aggregates along with various agricultural applications. As mineral filler, fly ash can be used for paints, shingles, carpet backing, plastics, metal castings and other purposes. This quick reference card is intended to provide the reader basic source, identification and composition, information specifically related to fly ash.

  17. Reference-frame-independent quantum key distribution

    SciTech Connect (OSTI)

    Laing, Anthony; Rarity, John G.; O'Brien, Jeremy L. [Centre for Quantum Photonics, H. H. Wills Physics Laboratory and Department of Electrical and Electronic Engineering, University of Bristol, BS8 1UB (United Kingdom); Scarani, Valerio [Centre for Quantum Technologies and Department of Physics, National University of Singapore (Singapore)

    2010-07-15T23:59:59.000Z

    We describe a quantum key distribution protocol based on pairs of entangled qubits that generates a secure key between two partners in an environment of unknown and slowly varying reference frame. A direction of particle delivery is required, but the phases between the computational basis states need not be known or fixed. The protocol can simplify the operation of existing setups and has immediate applications to emerging scenarios such as earth-to-satellite links and the use of integrated photonic waveguides. We compute the asymptotic secret key rate for a two-qubit source, which coincides with the rate of the six-state protocol for white noise. We give the generalization of the protocol to higher-dimensional systems and detail a scheme for physical implementation in the three-dimensional qutrit case.

  18. Credit and Trade References President and Fellows of Harvard College

    E-Print Network [OSTI]

    Credit and Trade References President and Fellows of Harvard College 1033 Massachusetts Avenue, 2nd;Trade References VWR International Risk Department Contact: Brian Newton TEL: 770-792-1271 FAX: 484

  19. SPD SEIS References for Appendix F | National Nuclear Security...

    National Nuclear Security Administration (NNSA)

    SPD SEIS References for Appendix F SPD SEIS References for Appendix F Blunt, B., 2010, Savannah River Site, Aiken, South Carolina, personal communication (email) to J. DiMarzio,...

  20. "No two directions are ever the same": Transforming reference services

    E-Print Network [OSTI]

    Stratton, John M.; Devlin, Frances A.

    2008-07-29T23:59:59.000Z

    This poster provides information about the changes that have occurred in reference services at the University of Kansas (KU) Libraries since 2002. Our intent is to illustrate the evolution of thinking about reference ...

  1. It's Complicated!: The Continuing Evolution of the Reference Service Model

    E-Print Network [OSTI]

    Devlin, Frances A.; Ellis, Erin L.

    2010-08-06T23:59:59.000Z

    Digital resources and technologies have brought new dimensions to librarianship and traditional reference services. At the University of Kansas (KU) Libraries, reference services have been evolving and reconfigured several ...

  2. One in five online scholarly articles affected by 'reference...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    on reference rot, the combination of link rot and content drift to which references to web resources included in STM articles are subject. January 26, 2015 From left, Los Alamos...

  3. On the Intrinsic Locality Properties of Web Reference Streams

    E-Print Network [OSTI]

    Keinan, Alon

    On the Intrinsic Locality Properties of Web Reference Streams Rodrigo Fonseca Virg´ilio Almeida in the study of Web reference streams: sequences of requests for Web objects. In particular, many studies have into the nature of reference stream transformations in the Web. I. INTRODUCTION Considerable effort has gone

  4. Generating and Interpreting Referring Expressions in Dustin Arthur Smith

    E-Print Network [OSTI]

    Referring Expressions in Context by Dustin Arthur Smith Submitted to the Program of Media Arts and Sciences, MIT Media Lab #12;Generating and Interpreting Referring Expressions in Context by Dustin Arthur SmithGenerating and Interpreting Referring Expressions in Context by Dustin Arthur Smith B.S., Wake

  5. RECENT REFERENCES: APRIL 1, 2005 TO JUNE 30, 2005

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2005-06-30T23:59:59.000Z

    This document lists experimental references added to Nuclear Science References (NSR) during the period April 1, 2005 to June 30, 2005. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  6. RECENT REFERENCES: JANUARY 1, 2005 TO DECEMBER 31, 2005

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2005-12-31T23:59:59.000Z

    This document lists experimental references added to Nuclear Science References (NSR) during the period January 1, 2005 to December 31, 2005. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  7. RECENT REFERENCES: OCTOBER 1, 2005 TO DECEMBER 31, 2005

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2005-12-31T23:59:59.000Z

    This document lists experimental references added to Nuclear Science References (NSR) during the period October 1, 2005 to December 31, 2005. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  8. 54 | P a g e Terms of Reference

    E-Print Network [OSTI]

    Brownstone, Rob

    in campus sustainability by: o Working together to reduce the amount of water, energy and products we use 54 | P a g e Terms of Reference DALHOUSIE UNIVERSITY OFFICE OF SUSTAINABILITY Rethink: Sustainability on Campus SUSTAINABILITY TEAMS Terms of Reference 1.0 Introduction These terms of reference

  9. Using Enterprise Reference Models for Automated ISO 9000 Compliance Evaluation

    E-Print Network [OSTI]

    Fox, Mark S.

    1 Using Enterprise Reference Models for Automated ISO 9000 Compliance Evaluation Henry M. Kim1, and then compared to a reference model of "good" processes and structures, such as the ISO 9000 standards. In this paper, the TOVE ISO 9000 Micro-Theory is presented as a formal reference model of quality goodness. ISO

  10. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system. Volume 1

    SciTech Connect (OSTI)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01T23:59:59.000Z

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data.

  11. Interactive Volume Rendering of Diffusion Tensor Data

    E-Print Network [OSTI]

    Hlawitschka, Mario

    2010-01-01T23:59:59.000Z

    ller. Volumeshop: o Interactive direct volume illustration.Kin04] [KKW05] [KTW06] Interactive Volume Rendering of Di?magic volume lens: An interactive focus+context technique

  12. Autoignition of toluene reference fuels at high pressures modeled with detailed chemical kinetics

    SciTech Connect (OSTI)

    Andrae, J.C.G. [Department of Chemical Engineering and Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Shell Global Solutions, P.O. Box 1, Chester CH1 3SH (United Kingdom); Bjoernbom, P. [Department of Chemical Engineering and Technology, Royal Institute of Technology, SE-100 44 Stockholm (Sweden); Cracknell, R.F.; Kalghatgi, G.T. [Shell Global Solutions, P.O. Box 1, Chester CH1 3SH (United Kingdom)

    2007-04-15T23:59:59.000Z

    A detailed chemical kinetic model for the autoignition of toluene reference fuels (TRF) is presented. The toluene submechanism added to the Lawrence Livermore Primary Reference Fuel (PRF) mechanism was developed using recent shock tube autoignition delay time data under conditions relevant to HCCI combustion. For two-component fuels the model was validated against recent high-pressure shock tube autoignition delay time data for a mixture consisting of 35% n-heptane and 65% toluene by liquid volume. Important features of the autoignition of the mixture proved to be cross-acceleration effects, where hydroperoxy radicals produced during n-heptane oxidation dramatically increased the oxidation rate of toluene compared to the case when toluene alone was oxidized. Rate constants for the reaction of benzyl and hydroperoxyl radicals previously used in the modeling of the oxidation of toluene alone were untenably high for modeling of the mixture. To model both systems it was found necessary to use a lower rate and introduce an additional branching route in the reaction between benzyl radicals and O{sub 2}. Good agreement between experiments and predictions was found when the model was validated against shock tube autoignition delay data for gasoline surrogate fuels consisting of mixtures of 63-69% isooctane, 14-20% toluene, and 17% n-heptane by liquid volume. Cross reactions such as hydrogen abstractions between toluene and alkyl and alkylperoxy radicals and between the PRF were introduced for completion of chemical description. They were only of small importance for modeling autoignition delays from shock tube experiments, even at low temperatures. A single-zone engine model was used to evaluate how well the validated mechanism could capture autoignition behavior of toluene reference fuels in a homogeneous charge compression ignition (HCCI) engine. The model could qualitatively predict the experiments, except in the case with boosted intake pressure, where the initial temperature had to be increased significantly in order to predict the point of autoignition. (author)

  13. CRYSTALLINE CERAMIC WASTE FORMS: REFERENCE FORMULATION REPORT

    SciTech Connect (OSTI)

    Brinkman, K.; Fox, K.; Marra, J.

    2012-05-15T23:59:59.000Z

    The research conducted in this work package is aimed at taking advantage of the long term thermodynamic stability of crystalline ceramics to create more durable waste forms (as compared to high level waste glass) in order to reduce the reliance on engineered and natural barrier systems. Durable ceramic waste forms that incorporate a wide range of radionuclides have the potential to broaden the available disposal options and to lower the storage and disposal costs associated with advanced fuel cycles. Assemblages of several titanate phases have been successfully demonstrated to incorporate radioactive waste elements, and the multiphase nature of these materials allows them to accommodate variation in the waste composition. Recent work has shown that they can be successfully produced from a melting and crystallization process. The objective of this report is to explain the design of ceramic host systems culminating in a reference ceramic formulation for use in subsequent studies on process optimization and melt property data assessment in support of FY13 melter demonstration testing. The waste stream used as the basis for the development and testing is a combination of the projected Cs/Sr separated stream, the Trivalent Actinide - Lanthanide Separation by Phosphorous reagent Extraction from Aqueous Komplexes (TALSPEAK) waste stream consisting of lanthanide fission products, the transition metal fission product waste stream resulting from the transuranic extraction (TRUEX) process, and a high molybdenum concentration with relatively low noble metal concentrations. In addition to the combined CS/LN/TM High Mo waste stream, variants without Mo and without Mo and Zr were also evaluated. Based on the results of fabricating and characterizing several simulated ceramic waste forms, two reference ceramic waste form compositions are recommended in this report. The first composition targets the CS/LN/TM combined waste stream with and without Mo. The second composition targets with CS/LN/TM combined waste stream with Mo and Zr removed. Waste streams that contain Mo must be produced in reducing environments to avoid Cs-Mo oxide phase formation. Waste streams without Mo have the ability to be melt processed in air. A path forward for further optimizing the processing steps needed to form the targeted phase assemblages is outlined in this report. Processing modifications including melting in a reducing atmosphere, and controlled heat treatment schedules are anticipated to improve the targeted elemental partitioning.

  14. Reference repository design concept for bedded salt

    SciTech Connect (OSTI)

    Carpenter, D.W.; Martin, R.W.

    1980-10-08T23:59:59.000Z

    A reference design concept is presented for the subsurface portions of a nuclear waste repository in bedded salt. General geologic, geotechnical, hydrologic and geochemical data as well as descriptions of the physical systems are provided for use on generic analyses of the pre- and post-sealing performance of repositories in this geologic medium. The geology of bedded salt deposits and the regional and repository horizon stratigraphy are discussed. Structural features of salt beds including discontinuities and dissolution features are presented and their effect on repository performance is discussed. Seismic hazards and the potential effects of earthquakes on underground repositories are presented. The effect on structural stability and worker safety during construction from hydrocarbon and inorganic gases is described. Geohydrologic considerations including regional hydrology, repository scale hydrology and several hydrological failure modes are presented in detail as well as the hydrological considerations that effect repository design. Operational phase performance is discussed with respect to operations, ventilation system, shaft conveyances, waste handling and retrieval systems and receival rates of nuclear waste. Performance analysis of the post sealing period of a nuclear repository is discussed, and parameters to be used in such an analysis are presented along with regulatory constraints. Some judgements are made regarding hydrologic failure scenarios. Finally, the design and licensing process, consistent with the current licensing procedure is described in a format that can be easily understood.

  15. Nuclear reactor engineering: Reactor design basics. Fourth edition, Volume One

    SciTech Connect (OSTI)

    Glasstone, S.; Sesonske, A.

    1994-12-31T23:59:59.000Z

    This new edition of this classic reference combines broad yet in-depth coverage of nuclear engineering principles with practical descriptions of their application in design and operation of nuclear power plants. Extensively updated, the fourth edition includes new material on reactor safety and risk analysis, regulation, fuel management, waste management, and operational aspects of nuclear power. This volume contains the following: energy from nuclear fission; nuclear reactions and radiations; neutron transport; nuclear design basics; nuclear reactor kinetics and control; radiation protection and shielding; and reactor materials.

  16. Nuclear reactor engineering: Reactor systems engineering. Fourth edition, Volume Two

    SciTech Connect (OSTI)

    Glasstone, S.; Sesonske, A.

    1994-12-31T23:59:59.000Z

    This new edition of this classic reference combines broad yet in-depth coverage of nuclear engineering principles with practical descriptions of their application in the design and operation of nuclear power plants. Extensively updated, the fourth edition includes new materials on reactor safety and risk analysis, regulation, fuel management, waste management and operational aspects of nuclear power. This volume contains the following: the systems concept, design decisions, and information tools; energy transport; reactor fuel management and energy cost considerations; environmental effects of nuclear power and waste management; nuclear reactor safety and regulation; power reactor systems; plant operations; and advanced plants and the future.

  17. Precision Tiltmeter as a Reference for Slope Measuring Instruments

    E-Print Network [OSTI]

    Kirschman, Jonathan L.; Domning, Edward E.; Morrison, Gregory Y.; Smith, Brian V.; Yashchuk, Valeriy V.

    2008-01-01T23:59:59.000Z

    LSBL-798, (2006). Applied Geomechanics Technical Note: “this volume. Applied Geomechanics 755-1172 Miniature Tiltof a tiltmeter, Applied Geomechanics Model 755-1172, 11 for

  18. International linear collider reference design report

    SciTech Connect (OSTI)

    Aarons, G.

    2007-06-22T23:59:59.000Z

    The International Linear Collider will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. A proposed electron-positron collider, the ILC will complement the Large Hadron Collider, a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, together unlocking some of the deepest mysteries in the universe. With LHC discoveries pointing the way, the ILC -- a true precision machine -- will provide the missing pieces of the puzzle. Consisting of two linear accelerators that face each other, the ILC will hurl some 10 billion electrons and their anti-particles, positrons, toward each other at nearly the speed of light. Superconducting accelerator cavities operating at temperatures near absolute zero give the particles more and more energy until they smash in a blazing crossfire at the centre of the machine. Stretching approximately 35 kilometres in length, the beams collide 14,000 times every second at extremely high energies -- 500 billion-electron-volts (GeV). Each spectacular collision creates an array of new particles that could answer some of the most fundamental questions of all time. The current baseline design allows for an upgrade to a 50-kilometre, 1 trillion-electron-volt (TeV) machine during the second stage of the project. This reference design provides the first detailed technical snapshot of the proposed future electron-positron collider, defining in detail the technical parameters and components that make up each section of the 31-kilometer long accelerator. The report will guide the development of the worldwide R&D program, motivate international industrial studies and serve as the basis for the final engineering design needed to make an official project proposal later this decade.

  19. REORIENTAO Ensino Mdio -Volume I

    E-Print Network [OSTI]

    Liu, I-Shih

    REORIENTAÇÃO CURRICULAR PORTUGUÊS Ensino Médio - Volume I Materiais Didáticos #12;#12;GOVERNO DO SUBSECRETARIA ADJUNTA DE PLANEJAMENTO PEDAGÓGICO Alba Rodrigues Cruz #12;#12;GOVERNO DO ESTADO DO RIO DE JANEIRO

  20. FMDP reactor alternative summary report: Volume 4, Evolutionary LWR alternative

    SciTech Connect (OSTI)

    NONE

    1996-09-01T23:59:59.000Z

    Significant quantities of weapons-usable fissile materials [primarily plutonium and highly enriched uranium (HEU)] have become surplus to national defense needs both in the United States and Russia. These stocks of fissile materials pose significant dangers to national and international security. The dangers exist not only in the potential proliferation of nuclear weapons but also in the potential for environmental, safety, and health (ES&H) consequences if surplus fissile materials are not properly managed. The purpose of this report is to provide schedule, cost, and technical information that will be used to support the Record of Process (ROD). Following the screening process, DOE/MD via its national laboratories initiated a more detailed analysis activity to further evaluate each of the ten plutonium disposition alternatives that survived the screening process. Three ``Alternative Teams,`` chartered by DOE and comprised of technical experts from across the DOE national laboratory complex, conducted these analyses. One team was chartered for each of the major disposition classes (borehole, immobilization, and reactors). During the last year and a half, the Fissile Materials Disposition Program (FMDP) Reactor Alternative Team (RxAT) has conducted extensive analyses of the cost, schedule, technical maturity, S&S, and other characteristics of reactor-based plutonium disposition. The results of the RxAT`s analyses of the existing LWR, CANDU, and partially complete LWR alternatives are documented in Volumes 1-3 of this report. This document (Volume 4) summarizes the results of these analyses for the ELWR-based plutonium disposition option.

  1. International Linear Collider Technical Design Report (Volumes 1 through 4)

    SciTech Connect (OSTI)

    Harrison M.

    2013-03-27T23:59:59.000Z

    The design report consists of four volumes: Volume 1, Executive Summary; Volume 2, Physics; Volume 3, Accelerator (Part I, R and D in the Technical Design Phase, and Part II, Baseline Design); and Volume 4, Detectors.

  2. Volume-Duration-Frequencies for Ungaged Catchments in Texas

    E-Print Network [OSTI]

    Devulapalli, Ravi S.; Valdes, Juan B.

    of individual phases, consists of two volumes. Volume I (titled Volume-Duration-Frequencies for Ungaged Catchments in Texas: Calculation of Regional Regression Equations) presents the regional regression equations developed, while Volume II (titled Volume...

  3. Reference Model for Control and Automation Systems in Electrical...

    Office of Environmental Management (EM)

    Model for Control and Automation Systems in Electrical Power (October 2005) Reference Model for Control and Automation Systems in Electrical Power (October 2005) Modern...

  4. Reference Model for Control and Automation Systems in Electrical...

    Broader source: Energy.gov (indexed) [DOE]

    Reference Model for Control and Automation Systems in Electrical Power Version 1.2 October 12, 2005 Prepared by: Sandia National Laboratories' Center for SCADA Security Jason...

  5. The Hydrogen Laboratory and The Brazilian Reference Center for...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Laboratory & The Brazilian Reference Center for Hydrogen Energy December 09 th , 2009 Dr. Newton Pimenta Cristiano Pinto LH2 & CENEH The State University of Campinas UNICAMP...

  6. Polymorphic Typing of Variables and References GEOFFREY SMITH

    E-Print Network [OSTI]

    Smith, Geoffrey

    Polymorphic Typing of Variables and References GEOFFREY SMITH Florida International University reflect the views of the National Science Foundation. Authors' addresses: G. Smith, School of Computer

  7. Sandia National Laboratories: blade NDI reference sample library

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    NDI reference sample library Sandia Participated in AMII to Support American-Made Wind-Turbine Blades On December 3, 2014, in Computational Modeling & Simulation, Energy, Materials...

  8. 2012 Annual Merit Review Results Report - Cross-Reference of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Review Results Report - Cross-reference of Project Investigators, Projects, and Organizations 2011 Annual Merit Review Results Report - Hybrid and Vehicle Systems Technologies...

  9. 2014 Annual Merit Review Results Report - Cross-reference of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2012 Annual Merit Review Results Report - Cross-Reference of Project Investigtors, Projects, and Organizations 2011 Annual Merit Review Results Report - Hybrid and Vehicle Systems...

  10. 2013 Annual Merit Review Results Report - Cross-Reference of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Review Results Report - Cross-reference of Project Investigators, Projects, and Organizations 2011 Annual Merit Review Results Report - Hybrid and Vehicle Systems Technologies...

  11. approval reference number: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    REPORTING;Emergency Information Desk Reference 3 REPORTING AN EMERGENCY Police - Fire - Medical 9-1-1 Dialing 911 Sciences Campus (252) 744-3863 University...

  12. Detailed HCCI Exhaust Speciation - ORNL Reference Fuel Blends...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    HCCI Exhaust Speciation - ORNL Reference Fuel Blends Accurately measure exhaust profile from an HCCI engine with a variety of fuels and create a better understanding of HCCI...

  13. EFRC management reference document Energy Frontier Research Centers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    appropriate acknowledgment of the facility or equipment and its supporting agency. EFRC management reference document Energy Frontier Research Centers Acknowledgments of Support...

  14. FAQS Reference Guide – Safeguards and Security General Technical Base

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the July 2009 edition of DOE-STD-1123-2009, Safeguards and Security General Technical Base Qualification Standard.

  15. Draft SPD SEIS Master Reference List | National Nuclear Security...

    National Nuclear Security Administration (NNSA)

    Policy Act (NEPA) NEPA Reading Room Surplus Plutonium Disposition Supplemental Environmental Impact Statement Draft SPD SEIS Master Reference List Draft SPD SEIS Master...

  16. adt reference manual: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    LLSIM Reference Manual MIT - DSpace Summary: A program that simulates a Digital Equipment Corporation PDP-11 computer and many of its peripherals on the AI Laboratory Time Sharing...

  17. MPI: The Complete Reference Scientific and Engineering Computation

    E-Print Network [OSTI]

    Lu, Paul

    MPI: The Complete Reference #12; Scientific and Engineering Computation Janusz Kowalik, Editor Data Manchek, and Vaidy Sunderam, 1994 Enabling Technologies for Petaflops Computing by Thomas Sterling, Paul

  18. NERSC/DOE BER Requirements Workshop Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |IsLoveReference Materials ReferenceReference Materials Reference

  19. NERSC/DOE FES Requirements Workshop Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |IsLoveReference MaterialsReferenceReference Materials Reference

  20. Predicting oropharyngeal tumor volume throughout the course of radiation therapy from pretreatment computed tomography data using general linear models

    SciTech Connect (OSTI)

    Yock, Adam D., E-mail: ADYock@mdanderson.org; Kudchadker, Rajat J. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States)] [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States); Rao, Arvind [Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and the Graduate School of Biomedical Sciences, the University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States)] [Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and the Graduate School of Biomedical Sciences, the University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States); Dong, Lei [Scripps Proton Therapy Center, San Diego, California 92121 and The Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States)] [Scripps Proton Therapy Center, San Diego, California 92121 and The Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States); Beadle, Beth M.; Garden, Adam S. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)] [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Court, Laurence E. [Department of Radiation Physics and Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States)] [Department of Radiation Physics and Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The Graduate School of Biomedical Sciences, The University of Texas Health Science Center at Houston, Houston, Texas 77030 (United States)

    2014-05-15T23:59:59.000Z

    Purpose: The purpose of this work was to develop and evaluate the accuracy of several predictive models of variation in tumor volume throughout the course of radiation therapy. Methods: Nineteen patients with oropharyngeal cancers were imaged daily with CT-on-rails for image-guided alignment per an institutional protocol. The daily volumes of 35 tumors in these 19 patients were determined and used to generate (1) a linear model in which tumor volume changed at a constant rate, (2) a general linear model that utilized the power fit relationship between the daily and initial tumor volumes, and (3) a functional general linear model that identified and exploited the primary modes of variation between time series describing the changing tumor volumes. Primary and nodal tumor volumes were examined separately. The accuracy of these models in predicting daily tumor volumes were compared with those of static and linear reference models using leave-one-out cross-validation. Results: In predicting the daily volume of primary tumors, the general linear model and the functional general linear model were more accurate than the static reference model by 9.9% (range: ?11.6%–23.8%) and 14.6% (range: ?7.3%–27.5%), respectively, and were more accurate than the linear reference model by 14.2% (range: ?6.8%–40.3%) and 13.1% (range: ?1.5%–52.5%), respectively. In predicting the daily volume of nodal tumors, only the 14.4% (range: ?11.1%–20.5%) improvement in accuracy of the functional general linear model compared to the static reference model was statistically significant. Conclusions: A general linear model and a functional general linear model trained on data from a small population of patients can predict the primary tumor volume throughout the course of radiation therapy with greater accuracy than standard reference models. These more accurate models may increase the prognostic value of information about the tumor garnered from pretreatment computed tomography images and facilitate improved treatment management.

  1. Site locality identification study: Hanford Site. Volume II. Data cataloging

    SciTech Connect (OSTI)

    Not Available

    1980-07-01T23:59:59.000Z

    Data compilation and cataloging for the candidate site locality identification study were conducted in order to provide a retrievable data cataloging system for the present siting study and future site evaluation and licensng processes. This task occurred concurrently with and also independently of other tasks of the candidate site locality identification study. Work in this task provided the data utilized primarily in the development and application of screening and ranking processes to identify candidate site localities on the Hanford Site. The overall approach included two steps: (1) data acquisition and screening; and (2) data compilation and cataloging. Data acquisition and screening formed the basis for preliminary review of data sources with respect to their probable utilization in the candidate site locality identification study and review with respect to the level of completeness and detail of the data. The important working assumption was that the data to be used in the study be based on existing and available published and unpublished literature. The data compilation and cataloging provided the basic product of the Task; a retrievable data cataloging system in the form of an annotated reference list and key word index and an index of compiled data. The annotated reference list and key word index are cross referenced and can be used to trace and retrieve the data sources utilized in the candidate site locality identification study.

  2. Reference materials for water and wastewater analyses in USEPA (U. S. Environmental Protection Agency)

    SciTech Connect (OSTI)

    Winter, J.A.

    1984-01-01T23:59:59.000Z

    The Environmental Monitoring and Support Laboratory at Cincinnati provides quality assurance support for EPA's water-related programs in response to the Clean Water Act, the Safe Drinking Water Act, the Marine Protection, Research and Sanctuaries Act, the Resources Conservation and Recovery Act, the Comprehensive Environmental Response Compensation and Liability Act, and the Toxic Substances Control Act. Two important segments of this support are: (1) the Quality Control (QC) Sample Program which provides samples of known concentrations for use as independent Hazardous Materials which provides calibration standards for trace organic analyses of interest to the Agency. The samples and standards are prepared as stable concentrated solutions in all-glass ampuls. Each series contains one or more related analyses, each with a true or reference value. These are provided for dilution to volume and analyses as needed by EPA, EPA contractor/grantees, and other federal, state and local agencies.

  3. Empowering the Frontline: A Dynamic Online Reference Manual and Training Session for Student Library Employee Reference Skills

    E-Print Network [OSTI]

    Loo, Jeffery L; Quigley, Brian D; Ngo, Lisa T; Powell, Susan; Teplitzky, Samantha

    2015-01-01T23:59:59.000Z

    training across our libraries’ service points. To developSession for Student Library Employee Reference SkillsTraining Design 5 libraries Engineering & Physical Sciences

  4. Using Prefetching to Improve Reference-Counting Garbage Collectors

    E-Print Network [OSTI]

    Petrank, Erez

    Using Prefetching to Improve Reference-Counting Garbage Collectors Harel Paz 1 and Erez Petrank 2 1-counting collector. We propose potential prefetching opportunities for the advanced reference-counting collector and report an implementation of a collector that employs such prefetch- ing. The proposed prefetch

  5. General References Name Author(s) of Book

    E-Print Network [OSTI]

    Pamela J. Bennett; Gary Y. Gao; David L; Clement; Ethel Dutky; Michael A; Dirr; Charles W; Fred Hower; Alison; Michael A; Of Woody Plant; Of North

    This is the third Special Circular installment of useful horticultural references for green-industry professionals, horticultural educators, and gardeners. This work-in-progress is a compilation of references that horticulturists use on a regular basis. If there are any books that should be added to this list,

  6. TLG Beta Code Quick Reference Guide Revised: July 16, 2009

    E-Print Network [OSTI]

    Loudon, Catherine

    TLG Beta Code Quick Reference Guide Revised: July 16, 2009 This document provides a quick reference to Beta Code and its Unicode equivalents. For a comprehensive overview of Beta Code, please see the TLG Beta Code Manual. Unicode equivalents are correct as of Unicode 5.1. Table of Contents Notes

  7. Archived Reference Climate Zone: 3B Los Angeles, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  8. Archived Reference Climate Zone: 3B Los Angeles, California

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  9. Archived Reference Climate Zone: 3B Las Vegas, Nevada

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Climate Zone: 3B Las Vegas, Nevada

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Climate Zone: TMY2 Weather Data

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Climate Zone: TMY2 Weather Data

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  13. UNIVERSITY COUNCIL ON ANIMAL CARE (UCAC) Terms of Reference

    E-Print Network [OSTI]

    Lennard, William N.

    's Terms of Reference; AUS-approved Standard Operating Procedures (SOPs). b) Ensure that the University, maintenance and use of animals as defined by the Canadian Council on Animal Care (CCAC), hereafter referred Canada. iv) The Canadian Association of Laboratory Medicine's Standards of Animal Care; v) The Animals

  14. Titanium Language Reference Manual Version 2.20

    E-Print Network [OSTI]

    California at Irvine, University of

    Titanium Language Reference Manual Version 2.20 P. N. Hilfinger (editor), Dan Bonachea, Kaushik Berkeley, California 94720 #12;Titanium Language Reference Manual Version 2.20 P. N. Hilfinger (editor, and Katherine Yelick August, 2006 #12;Abstract The Titanium language is a Java dialect for high

  15. Archived Reference Climate Zone: 2A Houston, Texas

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  16. Archived Reference Climate Zone: 2A Houston, Texas

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  17. Title list of documents made publicly available, April 1-30, 1995. Volume 17, No. 4

    SciTech Connect (OSTI)

    NONE

    1995-06-01T23:59:59.000Z

    This document is NUREG-0540, Volume 17, Number 4. The Title List of Documents Made Publicly Available is a monthly publication, It contains descriptions of the information received and generated by the US NRC. This information includes (1) docketed material associated with civilian nuclear power plants and other uses of radioactive materials, and (2) nondocketed material received and generated by the NRC pertinent to its role as a regulatory agency. As used here, docketed does not refer to Court dockets; it refers to the system by which the NRC maintains its regulatory records. This series of documents is indexed by a personal author index, a corporate source index, and a report number index.

  18. Model documentation: Electricity Market Module, Load and Demand-Side Management submodule. Volume 2, Model code listing

    SciTech Connect (OSTI)

    Not Available

    1994-04-07T23:59:59.000Z

    Volume II of the documentation contains the actual source code of the LDSM submodule, and the cross reference table of its variables. The code is divided into two parts. The first part contains the main part of the source code. The second part lists the INCLUDE files referenced inside the main part of the code.

  19. Technology, safety, and costs of decommissioning a reference large irradiator and reference sealed sources

    SciTech Connect (OSTI)

    Haffner, D.R.; Villelgas, A.J. [Pacific Northwest Lab., Richland, WA (United States)

    1996-01-01T23:59:59.000Z

    This report contains the results of a study sponsored by the US Nuclear Regulatory Commission (NRC) to examine the decommissioning of large radioactive irradiators and their respective facilities, and a broad spectrum of sealed radioactive sources and their respective devices. Conceptual decommissioning activities are identified, and the technology, safety, and costs (in early 1993 dollars) associated with decommissioning the reference large irradiator and sealed source facilities are evaluated. The study provides bases and background data for possible future NRC rulemaking regarding decommissioning, for evaluation of the reasonableness of planned decommissioning actions, and for determining if adequate funds are reserved by the licensees for decommissioning of their large irradiator or sealed source facilities. Another purpose of this study is to provide background and information to assist licensees in planning and carrying out the decommissioning of their sealed radioactive sources and respective facilities.

  20. Which BPS baryons minimize volume?

    SciTech Connect (OSTI)

    Evslin, Jarah; Kuperstein, Stanislav [Scuola Internazionale Superiore di Studi Avanzati (SISSA), Strada Costiera, Via Beirut n.2-4, 34013 Trieste (Italy); Theoretische Natuurkunde, Vrije Universiteit Brussel and The International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium)

    2009-02-15T23:59:59.000Z

    A Bogomol'nyi-Prasad-Sommerfield (BPS) 3-cycle in a Sasaki-Einstein 5-manifold in general does not minimize volume in its homology class, as we illustrate with several examples of nonminimal volume BPS cycles on the 5-manifolds Y{sup p,q}. Instead they minimize the energy of a wrapping D-brane, extremizing a generalized calibration. We present this generalized calibration and demonstrate that it reproduces both the Born-Infeld and the Wess-Zumino parts of the D3-brane energy.

  1. High air volume to low liquid volume aerosol collector

    DOE Patents [OSTI]

    Masquelier, Donald A. (Tracy, CA); Milanovich, Fred P. (Lafayette, CA); Willeke, Klaus (Cincinnati, OH)

    2003-01-01T23:59:59.000Z

    A high air volume to low liquid volume aerosol collector. A high volume flow of aerosol particles is drawn into an annular, centripetal slot in a collector which directs the aerosol flow into a small volume of liquid pool contained is a lower center section of the collector. The annular jet of air impinges into the liquid, imbedding initially airborne particles in the liquid. The liquid in the pool continuously circulates in the lower section of the collector by moving to the center line, then upwardly, and through assistance by a rotating deflector plate passes back into the liquid at the outer area adjacent the impinging air jet which passes upwardly through the liquid pool and through a hollow center of the collector, and is discharged via a side outlet opening. Any liquid droplets escaping with the effluent air are captured by a rotating mist eliminator and moved back toward the liquid pool. The collector includes a sensor assembly for determining, controlling, and maintaining the level of the liquid pool, and includes a lower centrally located valve assembly connected to a liquid reservoir and to an analyzer for analyzing the particles which are impinged into the liquid pool.

  2. Blue carbon storage potential of marine carbonate deposits Project reference IAP/13/50. Please quote this reference when applying.

    E-Print Network [OSTI]

    Guo, Zaoyang

    IAPETUS Blue carbon storage potential of marine carbonate deposits Project reference IAP/13 Henrik Stahl, Scottish Association for Marine Science Key Words 1. Blue carbon 2. Carbonate 3. Coralline is referred to as `blue carbon' to differentiate it from terrestrial carbon stores. Known blue carbon sinks

  3. National Solar Radiation Data Base (1961-1990). Final technical report. Volume 2

    SciTech Connect (OSTI)

    NONE

    1995-01-01T23:59:59.000Z

    The 1961-1990 National Solar Radiation Data Base (NSRDB) for the United States was completed in September 1992. This was the final product of four years of work under the U.S. Department of Energy (DOE) Solar Radiation Resource Assessment Project. The NSRDB contains 30 years of hourly data for five solar radiation elements and 15 meteorological elements for 239 sites. The user`s manual (NSRDB-Volume 1, 1992) for the NSRDB provides detailed information on the structure of the data base and the products that have been produced from it. Most users of the data base will find all of the information that they need in Volume 1. Volume 2 has been written primarily for researchers who need more information about the methods employed in producing the data base. In addition to research results, we have included information on practical lessons learned from this project. Therefore, Volume 2 should be of value to anyone developing a similar data base for other regions or other countries. Most of the solar radiation data in the NSRDB and the previous SOLMET (SOLar METeorological) data base were generated by computer models. Therefore, a major part of this report is centered around the METeorological/STATistical (METSTAT) model (Section 3.0), its input data (Sections 5.0 and 6.0), its use in producing the NSRDB (Sections 4.0 and 7.0), and comparisons with the models used in producing the SOLMET data base (Section 10.0).

  4. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    times the long-term, volume production costs for medium-pressure and high-pressure compressors, respectively. The new compressor cost models used in this HRSAM economic analysis...

  5. High-Temperature-High-Volume Lifting for Enhanced Geothermal...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems High-Temperature-High-Volume Lifting for...

  6. PATRAM '80. Proceedings. Volume 2

    SciTech Connect (OSTI)

    Huebner, H.W. (ed.)

    1980-01-01T23:59:59.000Z

    Volume 2 contains papers from the following sessions: Safeguards-Related Problems; Neutronics and Criticality; Operations and Systems Experience II; Plutonium Systems; Intermediate Storage in Casks; Operations and Systems Planning; Institutional Issues; Structural and Thermal Evaluation I; Poster Session B; Extended Testing I; Structural and Thermal Evaluation II; Extended Testing II; and Emergency Preparedness and Response. Individual papers were processed. (LM)

  7. PATRAM '80. Proceedings. Volume 1

    SciTech Connect (OSTI)

    Huebner, H.W. (ed.)

    1980-01-01T23:59:59.000Z

    Volume 1 contains papers from the following sessions: Plenary Session; Regulations, Licensing and Standards; LMFBR Systems Concepts; Risk/Safety Assessment I; Systems and Package Design; US Institutional Issues; Risk/Safety Assessment II; Leakage, Leak Rate and Seals; Poster Session A; Operations and Systems Experience I; Manufacturing Processes and Materials; and Quality Assurance and Maintenance. Individual papers were processed. (LM)

  8. Neuron, Volume 78 Supplemental Information

    E-Print Network [OSTI]

    Gentner, Timothy

    Neuron, Volume 78 Supplemental Information Associative Learning Enhances Population Coding colored dot denotes the mean response for two neurons to each of four stimuli. Each colored ellipse) For a positive relationship, neuron pairs with positive signal correlation and large noise correlation have

  9. IEA Wind Task 24 Integration of Wind and Hydropower Systems; Volume 2: Participant Case Studies

    SciTech Connect (OSTI)

    Acker, T.

    2011-12-01T23:59:59.000Z

    This report describes the background, concepts, issues and conclusions related to the feasibility of integrating wind and hydropower, as investigated by the members of IEA Wind Task 24. It is the result of a four-year effort involving seven IEA member countries and thirteen participating organizations. The companion report, Volume 2, describes in detail the study methodologies and participant case studies, and exists as a reference for this report.

  10. Economic evaluation of the annual cycle energy system (ACES). Final report. Volume III, appendices

    SciTech Connect (OSTI)

    Not Available

    1980-06-01T23:59:59.000Z

    This volume consists of seven appendices related to ACES, the first three of which are concerned with computer programs. The appendices are entitled: (A) ACESIM: Residential Program Listing; (B) Typical Inputs and Outputs of ACESIM; (C) CACESS: Commercial Building Program Listing; (D) Typical Weather-Year Selection Requirements; (E) Building Characteristics; (F) List of Major Variables Used in the Computer Programs; and (G) Bibliography. 79 references.

  11. NERSC/DOE BES Requirements Workshop Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |IsLoveReference MaterialsReference Materials Reference Materials

  12. ARE Update Volume 10, Number 5

    E-Print Network [OSTI]

    Sumner, Dan; Sexton, Steven E.; Rajagopal, Deepak; Zilberman, David D; Roland-Holst, David; Martin, Philip

    2007-01-01T23:59:59.000Z

    of Rising Demand for Biofuels and the Search for the Nextof Rising Demand for Biofuels and the Search for the NextThe current generation of biofuels, produced primarily from

  13. Arnold Schwarzenegger HIGH-VOLUME MANUFACTURING FOR

    E-Print Network [OSTI]

    Arnold Schwarzenegger Governor HIGH-VOLUME MANUFACTURING FOR LOW-COST, FLEXIBLE SOLAR CELL Prepared-VOLUME MANUFACTURING FOR LOW-COST, FLEXIBLE SOLAR CELL EISG AWARDEE InterPhases Research 166 N. Moorpark Rd. Suite 204

  14. MINIMAL VOLUME Laurent BESSI`ERES

    E-Print Network [OSTI]

    Remy, Bertrand

    MINIMAL VOLUME by Laurent BESSI`ERES Abstract. -- The aim of this text is to explain some rigidity manifold, simplicial volume, global topological meth- ods (`a la Gromov). #12;2 LAURENT BESSI`ERES 1

  15. Technology, safety and costs of decommissioning a Reference Boiling Water Reactor Power Station. Main report. Volume 1

    SciTech Connect (OSTI)

    Oak, H.D.; Holter, G.M.; Kennedy, W.E. Jr.; Konzek, G.J.

    1980-06-01T23:59:59.000Z

    Technology, safety and cost information is given for the conceptual decommissioning of a large (1100MWe) boiling water reactor (BWR) power station. Three approaches to decommissioning, immediate dismantlement, safe storage with deferred dismantlement and entombment, were studied to obtain comparisons between costs, occupational radiation doses, potential dose to the public and other safety impacts. It also shows the sensitivity of decommissioning safety and costs to the power rating of a BWR in the range of 200 to 1100 MWe.

  16. Archive Reference Buildings by Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  17. adolescents reference values: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    final paper in BG if available. Hypoxia and cyanobacteria not natural features of the Baltic Sea L. Zilln; D. J. Conley; Tables Figures 2010-01-01 58 References: Grundlagen....

  18. acr-1000 reference fuel: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Constraint Management in Fuel Cells: A Fast Reference Governor Approach Energy Storage, Conversion and Utilization...

  19. Naming, Reference, and Sense: Theoretical and Practical Attitudes at Odds

    E-Print Network [OSTI]

    Norman, Andrew

    Naming, Reference, and Sense: Theoretical and Practical Attitudes at Odds ANDREW NORMAN Northwestern University Three questions lie at the center of the philosophical controversy over proper names: 1) Do proper names have a sense? 2) If so...

  20. Nuclear Science References Coding Manual D.F. Winchell

    E-Print Network [OSTI]

    Ohta, Shigemi

    Nuclear Science References Coding Manual D.F. Winchell National Nuclear Data Center Brookhaven and coding procedures for specific topics . . 18 3.2.1 NUCLEAR REACTIONS . . . . . . . . . . . . . . . . 19 3.2.2 RADIOACTIVITY . . . . . . . . . . . . . . . . . . . . 20 3.2.3 NUCLEAR STRUCTURE

  1. Annual Energy Outlook 2013 Early Release Reference Case

    Gasoline and Diesel Fuel Update (EIA)

    projected in the AEO2012 Reference case * All renewable fuels grow, but biomass and biofuels growth is slower than in AEO2012 * U.S. energy-related carbon dioxide emissions...

  2. academic reference works: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to Get References into RefWorks Engineering Websites Summary: time. Type in your search terms. 5. Import from a text file. This method works for some onlineWorks function is...

  3. advisory committee references: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AM in the Gemini O'Toole, Alice J. 8 ADVISORY COMMITTEE on PRESIDENTIAL SEARCH (ACoPS) TERMS OF REFERENCE Physics Websites Summary: and abide by the terms of this document as...

  4. Archive Reference Buildings by Building Type: Stand-alone retail

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  5. Archive Reference Buildings by Building Type: Small office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  6. NASA/TP--2003210793 Lunar Surface Reference Missions

    E-Print Network [OSTI]

    Rathbun, Julie A.

    Hanover, MD 21076-1320 #12;July 2003 NASA/TP--2003­210793 Lunar Surface Reference Missions: A Description Hanover, MD 21076-1320 Springfield, VA 22161 301-

  7. NBS SPEC. PUBL. 260 -16 Standard Reference Materials

    E-Print Network [OSTI]

    NBS SPEC. PUBL. 260 - 16 Standard Reference Materials: HOMOGENEITY CHARACTERIZATION OF NBS Materials: Homogeneity Characterization of NBS Spectrometric Standards IV: Preparation and Microprobe. L. Vieth Institute for Materials Research National Bureau of Standards Washington, D.C. 20234

  8. SPD SEIS References for Appendix D | National Nuclear Security...

    National Nuclear Security Administration (NNSA)

    D SPD SEIS References for Appendix D Christenbury, G., 2011, U.S. Department of Energy, Savannah River Site, Aiken, South Carolina, personal communication (email) to V. Kay, U.S....

  9. Archive Reference Buildings by Building Type: Large office

    Office of Energy Efficiency and Renewable Energy (EERE)

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  10. Archive Reference Buildings by Building Type: Fast food

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  11. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    A Baltimore, Maryland Reference Buildings by Climate Zone and Representative City: 4A Baltimore, Maryland In addition to the ZIP file for each building type, you can directly view...

  12. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    A Chicago, Illinois Reference Buildings by Climate Zone and Representative City: 5A Chicago, Illinois In addition to the ZIP file for each building type, you can directly view the...

  13. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    B Helena, Montana Reference Buildings by Climate Zone and Representative City: 6B Helena, Montana In addition to the ZIP file for each building type, you can directly view the...

  14. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    B Boulder, Colorado Reference Buildings by Climate Zone and Representative City: 5B Boulder, Colorado In addition to the ZIP file for each building type, you can directly view the...

  15. Reference Buildings by Climate Zone and Representative City:...

    Energy Savers [EERE]

    1A Miami, Florida Reference Buildings by Climate Zone and Representative City: 1A Miami, Florida In addition to the ZIP file for each building type, you can directly view the...

  16. Reference Buildings by Climate Zone and Representative City:...

    Energy Savers [EERE]

    7 Duluth, Minnesota Reference Buildings by Climate Zone and Representative City: 7 Duluth, Minnesota In addition to the ZIP file for each building type, you can directly view the...

  17. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    B Phoenix, Arizona Reference Buildings by Climate Zone and Representative City: 2B Phoenix, Arizona In addition to the ZIP file for each building type, you can directly view the...

  18. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    B Las Vegas, Nevada Reference Buildings by Climate Zone and Representative City: 3B Las Vegas, Nevada In addition to the ZIP file for each building type, you can directly view the...

  19. Reference Buildings by Climate Zone and Representative City:...

    Energy Savers [EERE]

    B Los Angeles, California Reference Buildings by Climate Zone and Representative City: 3B Los Angeles, California In addition to the ZIP file for each building type, you can...

  20. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    C San Francisco, California Reference Buildings by Climate Zone and Representative City: 3C San Francisco, California In addition to the ZIP file for each building type, you can...

  1. Reference Buildings by Climate Zone and Representative City:...

    Energy Savers [EERE]

    A Atlanta, Georgia Reference Buildings by Climate Zone and Representative City: 3A Atlanta, Georgia In addition to the ZIP file for each building type, you can directly view the...

  2. Reference Buildings by Climate Zone and Representative City:...

    Energy Savers [EERE]

    A Houston, Texas Reference Buildings by Climate Zone and Representative City: 2A Houston, Texas In addition to the ZIP file for each building type, you can directly view the...

  3. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    C Seattle, Washington Reference Buildings by Climate Zone and Representative City: 4C Seattle, Washington In addition to the ZIP file for each building type, you can directly view...

  4. Plutonium Certified Reference Materials Price List | U.S. DOE...

    Office of Science (SC) Website

    Reference Materials (CRM) Contact Information New Brunswick Laboratory U.S. Department of Energy Building 350 9800 South Cass Avenue Argonne, IL 60439-4899 P: (630) 252-2442 (NBL)...

  5. Archive Reference Buildings by Building Type: Strip mall

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  6. Quantum geometrodynamical description of the Universe in different reference frames

    E-Print Network [OSTI]

    T. P. Shestakova

    2002-05-16T23:59:59.000Z

    Several years ago the so-called quantum geometrodynamics in extended phase space was proposed. The main role in this version of quantum geometrodynamics is given to a wave function that carries information about geometry of the Universe as well as about a reference frame in which this geometry is studied. We consider the evolution of a physical object (the Universe) in ``physical'' subspace of extended configurational space, the latter including gauge and ghost degrees of freedom. A measure of the ``physical'' subspace depends on a chosen reference frame, in particular, a small variation of a gauge-fixing function results in changing the measure. Thus, a transition to another gauge condition (another reference frame) leads to non-unitary transformation of a physical part of the wave function. From the viewpoint of the evolution of the Universe in the ``physical'' subspace a transition to another reference frame is an irreversible process that may be important when spacetime manifold has a nontrivial topology.

  7. Library and Information Services Division Current References 2009-1

    E-Print Network [OSTI]

    Library and Information Services Division Current References 2009-1 The Year of Darwin 2009 Discovering Darwin at NOAA Central Library: Resources on Charles Darwin, Evolution, and the Galapagos Islands National Oceanographic Data Center NOAA Central Library October 2009 http

  8. NIST Standard Reference Database 17 NIST Chemical Kinetics Database

    E-Print Network [OSTI]

    NIST Standard Reference Database 17 __________________________________________________________ NIST Chemical Kinetics Database WindowsTM Version 2Q98 Users' Guide (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data

  9. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    new2004v1.35.0.zip refbldg3ausagaatlantanew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 3A Atlanta, Georgia...

  10. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    new2004v1.35.0.zip refbldg1ausaflmiaminew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 1A Miami, Florida...

  11. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    new2004v1.35.0.zip refbldg2ausatxhoustonnew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 2A Houston, Texas...

  12. Archive Reference Buildings by Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  13. Reference Buildings by Climate Zone and Representative City:...

    Broader source: Energy.gov (indexed) [DOE]

    B Albuquerque, New Mexico Reference Buildings by Climate Zone and Representative City: 4B Albuquerque, New Mexico In addition to the ZIP file for each building type, you can...

  14. Site Environmental Report for 2006. Volume I, Environment, Health, and Safety Division

    SciTech Connect (OSTI)

    none,

    2007-09-30T23:59:59.000Z

    Each year, Ernest Orlando Lawrence Berkeley National Laboratory prepares an integrated report on its environmental programs to satisfy the requirements of United States Department of Energy Order 231.1A, Environment, Safety, and Health Reporting.1 The Site Environmental Report for 2006 summarizes Berkeley Lab’s environmental management performance, presents environmental monitoring results, and describes significant programs for calendar year 2006. (Throughout this report, Ernest Orlando Lawrence Berkeley National Laboratory is referred to as “Berkeley Lab,” “the Laboratory,” “Lawrence Berkeley National Laboratory,” and “LBNL.”) The report is separated into two volumes. Volume I is organized into an executive summary followed by six chapters that contain an overview of the Laboratory, a discussion of the Laboratory’s environmental management system, the status of environmental programs, and summarized results from surveillance and monitoring activities. Volume II contains individual data results from surveillance and monitoring activities.

  15. Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    SciTech Connect (OSTI)

    NONE

    1996-02-26T23:59:59.000Z

    The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.

  16. Verifying Volume Rendering Using Discretization Error Analysis

    E-Print Network [OSTI]

    Kirby, Mike

    Verifying Volume Rendering Using Discretization Error Analysis Tiago Etiene, Daniel Jo¨nsson, Timo--We propose an approach for verification of volume rendering correctness based on an analysis of the volume rendering integral, the basis of most DVR algorithms. With respect to the most common discretization

  17. Newton-Cartan Gravity in Noninertial Reference Frames

    E-Print Network [OSTI]

    Leo Rodriguez; James St. Germaine-Fuller; Sujeev Wickramasekara

    2014-12-26T23:59:59.000Z

    We study properties of Newton-Cartan gravity under transformations into all noninertial, nonrelativistic reference frames. The set of these transformations has the structure of an infinite dimensional Lie group, called the Galilean line group, which contains as a subgroup the Galilei group. We show that the fictitious forces of noninertial reference frames are naturally encoded in the Cartan connection transformed under the Galilean line group. These noninertial forces, which are coordinate effects, do not contribute to the Ricci tensor which describes the curvature of Newtonian spacetime. We show that only the $00$-component of the Ricci tensor is non-zero and equal to ($4\\pi$ times) the matter density in any inertial or noninetial reference frame and that it leads to what may be called Newtonian ADM mass. While the Ricci field equation and Gauss law are both fulfilled by the same physical matter density in inertial and linearly accelerating reference frames, there appears a discrepancy between the two in rotating reference frames in that Gauss law holds for an effective mass density that differs from the physical matter density. This effective density has its origin in the simulated magnetic field that appears in rotating frames, highlighting a rather striking difference between linearly and rotationally accelerating reference frames. We further show that the dynamical equations that govern the simulated gravitational and magnetic fields have the same form as Maxwell's equations, a surprising conclusion given that these equations are well-known to obey special relativity (and $U(1)$-gauge symmetry), rather than Galilean symmetry.

  18. Petroleum supply annual 1993. Volume 1

    SciTech Connect (OSTI)

    Not Available

    1994-06-01T23:59:59.000Z

    The Petroleum Supply Annual (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1993 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains four sections: Summary Statistics, Detailed Statistics, Refinery Capacity, and Oxygenate Capacity each with final annual data. The second volume contains final statistics for each month of 1993, and replaces data previously published in the Petroleum Supply Monthly (PSM). The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. Below is a description of each section in Volume 1 of the PSA.

  19. Petroleum supply annual 1994. Volume 1

    SciTech Connect (OSTI)

    NONE

    1995-05-22T23:59:59.000Z

    The Petroleum Supply Annual (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1994 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains four sections: Summary Statistics, Detailed Statistics, Refinery Capacity, and Oxygenate Capacity each with final annual data. The second volume contains final statistics for each month of 1994, and replaces data previously published in the Petroleum Supply Monthly (PSM). The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. Below is a description of each section in Volume 1 of the PSA.

  20. Estimating Residual Solids Volume In Underground Storage Tanks

    SciTech Connect (OSTI)

    Clark, Jason L.; Worthy, S. Jason; Martin, Bruce A.; Tihey, John R.

    2014-01-08T23:59:59.000Z

    The Savannah River Site liquid waste system consists of multiple facilities to safely receive and store legacy radioactive waste, treat, and permanently dispose waste. The large underground storage tanks and associated equipment, known as the 'tank farms', include a complex interconnected transfer system which includes underground transfer pipelines and ancillary equipment to direct the flow of waste. The waste in the tanks is present in three forms: supernatant, sludge, and salt. The supernatant is a multi-component aqueous mixture, while sludge is a gel-like substance which consists of insoluble solids and entrapped supernatant. The waste from these tanks is retrieved and treated as sludge or salt. The high level (radioactive) fraction of the waste is vitrified into a glass waste form, while the low-level waste is immobilized in a cementitious grout waste form called saltstone. Once the waste is retrieved and processed, the tanks are closed via removing the bulk of the waste, chemical cleaning, heel removal, stabilizing remaining residuals with tailored grout formulations and severing/sealing external penetrations. The comprehensive liquid waste disposition system, currently managed by Savannah River Remediation, consists of 1) safe storage and retrieval of the waste as it is prepared for permanent disposition; (2) definition of the waste processing techniques utilized to separate the high-level waste fraction/low-level waste fraction; (3) disposition of LLW in saltstone; (4) disposition of the HLW in glass; and (5) closure state of the facilities, including tanks. This paper focuses on determining the effectiveness of waste removal campaigns through monitoring the volume of residual solids in the waste tanks. Volume estimates of the residual solids are performed by creating a map of the residual solids on the waste tank bottom using video and still digital images. The map is then used to calculate the volume of solids remaining in the waste tank. The ability to accurately determine a volume is a function of the quantity and quality of the waste tank images. Currently, mapping is performed remotely with closed circuit video cameras and still photograph cameras due to the hazardous environment. There are two methods that can be used to create a solids volume map. These methods are: liquid transfer mapping / post transfer mapping and final residual solids mapping. The task is performed during a transfer because the liquid level (which is a known value determined by a level measurement device) is used as a landmark to indicate solids accumulation heights. The post transfer method is primarily utilized after the majority of waste has been removed. This method relies on video and still digital images of the waste tank after the liquid transfer is complete to obtain the relative height of solids across a waste tank in relation to known and usable landmarks within the waste tank (cooling coils, column base plates, etc.). In order to accurately monitor solids over time across various cleaning campaigns, and provide a technical basis to support final waste tank closure, a consistent methodology for volume determination has been developed and implemented at SRS.

  1. Cross Section Evaluation Group shielding benchmark compilation. Volume II

    SciTech Connect (OSTI)

    Rose, P.F.; Roussin, R.W.

    1983-12-01T23:59:59.000Z

    At the time of the release of ENDF/B-IV in 1974, the Shielding Subcommittee had identified a series of 12 shielding data testing benchmarks (the SDT series). Most were used in the ENDF/B-IV data testing effort. A new concept and series was begun in the interim, the so-called Shielding Benchmark (SB) series. An effort was made to upgrade the SDT series as far as possible and to add new SB benchmarks. In order to be designated in the SB class, both an experiment and analysis must have been performed. The current recommended benchmark for Shielding Data Testing are listed. Until recently, the philosophy has been to include only citations to published references for shielding benchmarks. It is now our intention to provide adequate information in this volume for proper analysis of any new benchmarks added to the collection. These compilations appear in Section II, with the SB5 Fusion Reactor Shielding Benchmark as the first entry.

  2. Neuron, Volume 79 Supplemental Information

    E-Print Network [OSTI]

    Rash, John E.

    cytoplasmic connexin domain. **** Recognition of Cx34.7, Cx35 and Cx36 by the antibodies listed is indicated Epitope Source and Reference Connexin recognition**** Cx34.7 Cx35 Cx36 Cx34.7 IL* polyclonal perch Cx34.7 intracellular loop O'Brien, J. O'Brien et al., 2004 + - nd Cx36 Ab298* polyclonal mouse Cx36 Nagy, J.I. Rash et

  3. Probabilistic accident consequence uncertainty analysis: Food chain uncertainty assessment. Volume 2: Appendices

    SciTech Connect (OSTI)

    Brown, J. [National Radiological Protection Board (United Kingdom); Goossens, L.H.J.; Kraan, B.C.P. [Delft Univ. of Technology (Netherlands)] [and others

    1997-06-01T23:59:59.000Z

    This volume is the second of a two-volume document that summarizes a joint project by the US Nuclear Regulatory and the Commission of European Communities to assess uncertainties in the MACCS and COSYMA probabilistic accident consequence codes. These codes were developed primarily for estimating the risks presented by nuclear reactors based on postulated frequencies and magnitudes of potential accidents. This two-volume report, which examines mechanisms and uncertainties of transfer through the food chain, is the first in a series of five such reports. A panel of sixteen experts was formed to compile credible and traceable uncertainty distributions for food chain transfer that affect calculations of offsite radiological consequences. Seven of the experts reported on transfer into the food chain through soil and plants, nine reported on transfer via food products from animals, and two reported on both. The expert judgment elicitation procedure and its outcomes are described in these volumes. This volume contains seven appendices. Appendix A presents a brief discussion of the MAACS and COSYMA model codes. Appendix B is the structure document and elicitation questionnaire for the expert panel on soils and plants. Appendix C presents the rationales and responses of each of the members of the soils and plants expert panel. Appendix D is the structure document and elicitation questionnaire for the expert panel on animal transfer. The rationales and responses of each of the experts on animal transfer are given in Appendix E. Brief biographies of the food chain expert panel members are provided in Appendix F. Aggregated results of expert responses are presented in graph format in Appendix G.

  4. Volumes

    U.S. Energy Information Administration (EIA) Indexed Site

    W 872.9 1,737.8 282.7 2,893.4 W W 132.1 117.6 - 249.7 See footnotes at end of table. 220 Energy Information AdministrationPetroleum Marketing Annual 2002 Table 43. Refiner Motor...

  5. Volumes

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    W NA W 1,666.1 W 2,880.1 NA W 134.2 125.5 - 259.7 See footnotes at end of table. 220 Energy Information AdministrationPetroleum Marketing Annual 2001 Table 43. Refiner Motor...

  6. Volumes

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    8,415.8 39,569.3 40,215.9 122,708.5 26,876.5 189,800.8 10,466.7 10,604.8 10,129.5 14,302.8 - 24,432.4 February ... 40,637.5 41,953.1 43,328.9 133,687.6...

  7. Volumes

    Gasoline and Diesel Fuel Update (EIA)

    9,369.5 40,816.0 42,057.4 126,970.8 38,559.5 207,587.7 9,892.3 10,063.7 W 15,155.9 W 25,989.9 February ... 41,671.7 43,092.9 43,590.9 131,633.0 37,204.6...

  8. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of the particle with external electromagnetic fields (i.e., wiggler, undulator) or media (i.e., transition radiation, Cerenkov, Smith-Purcell, etc.). The Fourier component,...

  9. Volumes

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5 Tables July 1996 Energy Information Administration Office ofthroughYear JanYearFuel Consumption0 0 0 1996-2013 Lease1,706.6

  10. Volumes

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40 Buildingto17 34 44Year JanDecade Year-0 Year-11,113,016 1,124,7170 09,369.5

  11. Volumes

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40 Buildingto17 34 44Year JanDecade Year-0 Year-11,113,016 1,124,7170

  12. Volumes

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40 Buildingto17 34 44Year JanDecade Year-0 Year-11,113,016 1,124,717041,706.6

  13. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE VOGTLE18

  14. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE

  15. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0, NUMBER

  16. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0,

  17. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0,3 P H Y

  18. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0,3 P H

  19. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0,3 P H0

  20. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0,3 P

  1. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0,3

  2. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps to Predict4 VARIATIONS IN7VOGTLE VOGTLE0,318 P H

  3. Programmatic methods for addressing contaminated volume uncertainties.

    SciTech Connect (OSTI)

    DURHAM, L.A.; JOHNSON, R.L.; RIEMAN, C.R.; SPECTOR, H.L.; Environmental Science Division; U.S. ARMY CORPS OF ENGINEERS BUFFALO DISTRICT

    2007-01-01T23:59:59.000Z

    Accurate estimates of the volumes of contaminated soils or sediments are critical to effective program planning and to successfully designing and implementing remedial actions. Unfortunately, data available to support the preremedial design are often sparse and insufficient for accurately estimating contaminated soil volumes, resulting in significant uncertainty associated with these volume estimates. The uncertainty in the soil volume estimates significantly contributes to the uncertainty in the overall project cost estimates, especially since excavation and off-site disposal are the primary cost items in soil remedial action projects. The Army Corps of Engineers Buffalo District's experience has been that historical contaminated soil volume estimates developed under the Formerly Utilized Sites Remedial Action Program (FUSRAP) often underestimated the actual volume of subsurface contaminated soils requiring excavation during the course of a remedial activity. In response, the Buffalo District has adopted a variety of programmatic methods for addressing contaminated volume uncertainties. These include developing final status survey protocols prior to remedial design, explicitly estimating the uncertainty associated with volume estimates, investing in predesign data collection to reduce volume uncertainties, and incorporating dynamic work strategies and real-time analytics in predesign characterization and remediation activities. This paper describes some of these experiences in greater detail, drawing from the knowledge gained at Ashland1, Ashland2, Linde, and Rattlesnake Creek. In the case of Rattlesnake Creek, these approaches provided the Buffalo District with an accurate predesign contaminated volume estimate and resulted in one of the first successful FUSRAP fixed-price remediation contracts for the Buffalo District.

  4. Recovery of Navy distillate fuel from reclaimed product. Volume II. Literature review

    SciTech Connect (OSTI)

    Brinkman, D.W.; Whisman, M.L.

    1984-11-01T23:59:59.000Z

    In an effort to assist the Navy to better utilize its waste hydrocarbons, NIPER, with support from the US Department of Energy, is conducting research designed to ultimately develop a practical technique for converting Reclaimed Product (RP) into specification Naval Distillate Fuel (F-76). This first phase of the project was focused on reviewing the literature and available information from equipment manufacturers. The literature survey has been carefully culled for methodology applicable to the conversion of RP into diesel fuel suitable for Navy use. Based upon the results of this study, a second phase has been developed and outlined in which experiments will be performed to determine the most practical recycling technologies. It is realized that the final selection of one particular technology may be site-specific due to vast differences in RP volume and available facilities. A final phase, if funded, would involve full-scale testing of one of the recommended techniques at a refueling depot. The Phase I investigations are published in two volumes. Volume 1, Technical Discussion, includes the narrative and Appendices I and II. Appendix III, a detailed Literature Review, includes both a narrative portion and an annotated bibliography containing about 800 references and abstracts. This appendix, because of its volume, has been published separately as Volume 2.

  5. Symmetric construction of reference-frame-free qudits

    E-Print Network [OSTI]

    Jun Suzuki; Gelo Noel Macuja Tabia; Berthold-Georg Englert

    2008-10-17T23:59:59.000Z

    By exploiting a symmetric scheme for coupling $N$ spin-1/2 constituents (the physical qubits) to states with total angular momentum $N/2-1$, we construct rotationally invariant logical qudits of dimension $d=N-1$. One can encode all qudit states, and realize all qudit measurements, by this construction. The rotational invariance of all relevant objects enables one to transmit quantum information without having aligned reference frames between the parties that exchange the qudits. We illustrate the method by explicit constructions of reference-frame-free qubits and qutrits and, for the qubit case, comment on possible experimental implementations.

  6. The Reference Design for the ILC, Costs, and What's Next

    SciTech Connect (OSTI)

    Barish, Barry

    2007-03-26T23:59:59.000Z

    A Reference Design for the International Linear Collider was recently released. The scale of the ILC is such that it must be built by an international collaboration and the design is the culmination of a unique global effort. Through ICFA, a decision was made to base the design on superconducting RF technology and then the Global Design Effort (GDE) was created to coordinate the actual accelerator design toward a construction proposal. The reference design establishes all the features of the machine, and defines both the R&D program and engineering design that will now follow over the next few years.

  7. Development of a 1-butanol reference scale dynamic olfactometer

    E-Print Network [OSTI]

    Sorel, James Edward

    1982-01-01T23:59:59.000Z

    ABSTRACT Development of a 1-butanol Reference Scale Dynamic Olfactometer. (December 1982) James Edward Sorel, B. A. S. U. N. Y. at Buffalo; Chairman of Advisory Committee: Harry J. Suggs A portable 1-butanol reference scale dynamic olfactometer has... Presentation 6, Scale Steps sd, Scale Steps n Grouping* Descending Ascending Random 0. 031 -0. 040 -0. 061 0. 545 285 A 0. 565 285 A B 0. 475 285 B * Means with the same letter are not significantly different. The population means, 6, of observations...

  8. NERSC/DOE ASCR Requirements Workshop Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated Codes |IsLoveReference Materials Reference Materials Large Scale Computing

  9. Geothermal CSC Reference List | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation, search OpenEI Reference LibraryAdd to library Web Site:ExplorationReference List

  10. Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection RadiationRecord-SettingHead ofReference-Documents Sign InReference

  11. Scuttlebutt Volume 2, No. 1

    E-Print Network [OSTI]

    2008-01-01T23:59:59.000Z

    , of the USS Genesis. To CPT Kieran Bock and his crew, the officers and crew of the Southern Cross send their very best wishes and congratulations, and we wish them fair seas and LOTS of stars to follow. The ScuttleButt Volume 2, Issue 1 5 USS Atlantis... will be forwarded separately to each individual member. Please forward any enquiries to the Intel Officer - ENS Ashley Walker on alwalk78@optusnet.com.au. ENS Ashley Walker Operations Intelligence Officer Welcoming New Crewmembers Savannah Clark Daniel...

  12. Scuttlebutt Volume 2, No. 4

    E-Print Network [OSTI]

    2008-01-01T23:59:59.000Z

    ?s Sunshine Award & Crewmember of the Year Award. Polls close on Friday, July 18. Crewmembers may vote in the official site, http://groups.yahoo.com/group/uss-southerncrossawards/. The results Will be announced at the Summit. Summit Event Venues... of our good friends in Adelaide, reacquaint myself with my ?old? mates and make friends with new ones. See you in SA. COL Bruce O?Brien Commanding Officer Newsletter Publisher http://www.uss-southerncross.com/ July / August 2008 Volume 2, Issue 4...

  13. Environmental Report 1995. Volume 1

    SciTech Connect (OSTI)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M. [and others

    1996-09-01T23:59:59.000Z

    This report contains the results of Lawrence Livermore National Laboratory`s (LLNL) environmental monitoring and compliance effort and an assessment of the impact of LLNL operations on the environment and the public. This first volume describes LLNL`s environmental impact and compliance activities and features descriptive and explanatory text, summary data tables, and plots showing data trends. The summary data include measures of the center of data, their spread or variability, and their extreme values. Chapters on monitoring air, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation are present.

  14. Risperidone use in autism spectrum disorders: A retrospective review of a clinic-referred patient population

    E-Print Network [OSTI]

    Lemmon, ME; Lemmon, ME; Gregas, M; Gregas, M; Jeste, SS

    2011-01-01T23:59:59.000Z

    Retrospective Review of a Clinic-Referred Patient Populationaimed to (1) describe a clinic-referred sample of patientsof nonsuccess. In our clinic-referred sample, the short-term

  15. Complete References List Each chapter has their own list of references; however, it is useful to show the

    E-Print Network [OSTI]

    Todorovich, Elías

    04] Altera Corp. "Power Calculator User Guide", March 2004, available at http., Lopez-Buedo, S., Meneses, J., "Some Notes on Power Management on FPGAs", LNCS, No. 975, Springer] Anderson, J.H.; Najm, F.N., "Power estimation techniques for FPGAs", IEEE Trans. on VLSI Systems, Volume 12

  16. A distributed computing environment for volume visualization

    E-Print Network [OSTI]

    Barua, Sandip Pannalal

    1992-01-01T23:59:59.000Z

    in computer-aided instruction, and can be expected to be widely used in medical classrooms in the near future. Figure Remot W kststloos High Bandwidth I Li& I I I I I High Performance Computer Fig. 2. A real-time multi-user environment 2 could... Page Volume Rendering Time 48 Normalized and Processor Performance Compensated Volume Ren- dering Time 49 III Computation Overhead - Ray Trace Phase 51 IV Computation Overhead - Volume Build Phase . 51 CHAPTER I INTRODUCTION I. A Scientific...

  17. Petroleum supply annual 1995: Volume 1

    SciTech Connect (OSTI)

    NONE

    1996-05-01T23:59:59.000Z

    The {ital Petroleum Supply Annual} contains information on supply and disposition of crude oil and petroleum products. It reflects data collected from the petroleum industry during 1995 through monthly surveys, and it is divided into 2 volumes. This volume contains three sections: summary statistics, detailed statistics, and selected refinery statistics, each with final annual data. (The other volume contains final statistics for each month and replaces data previously published in the {ital Petroleum Supply Monthly}).

  18. A distributed computing environment for volume visualization 

    E-Print Network [OSTI]

    Barua, Sandip Pannalal

    1992-01-01T23:59:59.000Z

    in computer-aided instruction, and can be expected to be widely used in medical classrooms in the near future. Figure Remot W kststloos High Bandwidth I Li& I I I I I High Performance Computer Fig. 2. A real-time multi-user environment 2 could... Page Volume Rendering Time 48 Normalized and Processor Performance Compensated Volume Ren- dering Time 49 III Computation Overhead - Ray Trace Phase 51 IV Computation Overhead - Volume Build Phase . 51 CHAPTER I INTRODUCTION I. A Scientific...

  19. Modeling the Arterial System with Reference to an Anesthesia Simulator

    E-Print Network [OSTI]

    Olufsen, Mette Sofie

    Modeling the Arterial System with Reference to an Anesthesia Simulator Ph.D. Thesis 1 by Mette), and at the Department of Anesthesia, Herlev University Hospital. The study has been organized as an industrial Ph S.A. Pedersen, Roskilde University, and M.D. P.F. Jensen, Ph.D., Department of Anesthesia, Herlev

  20. Finance Committee Terms of Reference, Membership and Operating Procedures

    E-Print Network [OSTI]

    Botea, Adi

    95/2012 Finance Committee ­ Terms of Reference, Membership and Operating Procedures Principles 1 on, or pose any reasonable risk to, the University's finances and operations" section 18(4)(d). 3. Council has established a Finance Committee as a committee of Council. 4. The broad purpose of the Finance

  1. Introduction Wikipedia Revision History Applications Conclusions References Mining Wikipedia's

    E-Print Network [OSTI]

    Neumann, Günter

    Revision History Revision History Plots Figure: RH plots for articles 2005 (5,714 rev.) and 2007 (11,494 rev.) Mihai Grigore Mining Wikipedia's Article Revision History 5/24 #12;Introduction WikipediaIntroduction Wikipedia Revision History Applications Conclusions References Mining Wikipedia

  2. Reference: RGL 83-09 Subject: POWER TRANSMISSION LINES

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Reference: RGL 83-09 Subject: POWER TRANSMISSION LINES Title: MARKING OF AERIAL POWER TRANSMISSION. 1. The marking of aerial power transmission lines, cables, and structures over the navigable waters LINES, CABLES, & STRUCTURES Issued: 07/13/83 Expires: 12/31/85 Originator: DAEN-CWO-N Description: ARMY

  3. Environmental Guidance Program Reference Book: American Indian Religious Freedom Act

    SciTech Connect (OSTI)

    Not Available

    1987-11-01T23:59:59.000Z

    This Reference Book contains a copy of the American Indian Religious Freedom Act and guidance for DOE compliance with the statute. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. Updates that include important new requirements will be provided periodically.

  4. www.blackwellreference.com Your destination for authoritative reference materials

    E-Print Network [OSTI]

    Chen, Sheng-Wei

    ;Quick Search Enter your search term in the search bar in the top corner of the home page, e within these results: Enter the more specific term in the search bar, e.g. Coca-Cola or Select their library's OPAC, or through Blackwell Reference Online's sophisticated tools for browsing, searching

  5. Reference: RGL 81-01 Subject: NATIONWIDE PERMIT-MAINTENANCE

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Reference: RGL 81-01 Subject: NATIONWIDE PERMIT-MAINTENANCE Title: MAINTENANCE DREDGING TO MAINTAIN EXISTING STRUCTURE IN SEC 10 WATERS DOES NOT AUTHORIZE MAINTENANCE DREDGING (1977 REGS). 1 applicable to maintenance dredging. 2. Nationwide permit 322.4(c) authorizes the repair, rehabilitation

  6. Algorithm for Treatment of Hypertension Reference Card From the

    E-Print Network [OSTI]

    Bandettini, Peter A.

    Algorithm for Treatment of Hypertension Reference Card From the Seventh Report of the Joint Prehypertension 120­139 or 80­89 Hypertension, Stage 1 140­159 or 90­99 Hypertension, Stage 2 160 or 100 · Assess risk factors and comorbidities. · Reveal identifiable causes of hypertension. · Assess presence

  7. Reference wind farm selection for regional wind power prediction models

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Reference wind farm selection for regional wind power prediction models Nils Siebert George.siebert@ensmp.fr, georges.kariniotakis@ensmp.fr Abstract Short-term wind power forecasting is recognized today as a major requirement for a secure and economic integration of wind generation in power systems. This paper deals

  8. Wind Energy Learning Curves for Reference in Expert Elicitations

    E-Print Network [OSTI]

    Mountziaris, T. J.

    Wind Energy Learning Curves for Reference in Expert Elicitations Sarah Mangels, Erin Baker. Abstract: This study presents future projections of wind energy capacity and cost based on historical data. The study will be used during wind- energy expert elicitations (formal interviews aimed to quantify

  9. Page Replacement and Reference Bit Emulation in Mach

    E-Print Network [OSTI]

    Page Replacement and Reference Bit Emulation in Mach Richard P. Draves rpd@cs.cmu.edu School of Computer Science Carnegie Mellon University 5000 Forbes Avenue Pittsburgh, PA 15213 Abstract A page­replacement in software. This paper describes the Mach kernel's page­replacement algorithm and considers three software

  10. Reference: RGL 83-04 Subject: PUBLIC NOTICE-AGRICULTURE

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Reference: RGL 83-04 Subject: PUBLIC NOTICE-AGRICULTURE Title: DISTRIBUTION OF PUBLIC NOTICES FOR ACTIVITIES INVOLVING AGRICULTURAL CONVERSIONS Issued: 03/04/83 Expires: 12/31/85 Originator: DAEN AGRICULTURAL USE OF LAND. 1. If an applicant's proposal involves the conversion of land so as to increase

  11. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    REFERENCE: The Blue Planet An Introduction to Earth System Science. Brian J. Skinner and Barbara of the Earth system. · Describe the cycles of the materials and energy through the Earth system. · Learn how science works and how models are used in Earth system science. #12;"It is the science that studies

  12. Site-Searching Strategies of Searchers Referred from Search Engines

    E-Print Network [OSTI]

    Jansen, James

    1 Site-Searching Strategies of Searchers Referred from Search Engines Adan Ortiz-Cordova College and then submit multiple broad queries on the site-search engine, (2) the navigators who submit a query to the major search engine that is part of a URL and then submit specific queries to the site-search engine

  13. Precision Tiltmeter as a Reference for Slope MeasuringInstruments

    SciTech Connect (OSTI)

    Kirschman, Jonathan L.; Domning, Edward E.; Morrison, Gregory Y.; Smith, Brian V.; Yashchuk, Valeriy V.

    2007-08-01T23:59:59.000Z

    The next generation of synchrotrons and free electron lasers require extremely high-performance x-ray optical systems for proper focusing. The necessary optics cannot be fabricated without the use of precise optical metrology instrumentation. In particular, the Long Trace Profiler (LTP) based on the pencil-beam interferometer is a valuable tool for low-spatial-frequency slope measurement with x-ray optics. The limitations of such a device are set by the amount of systematic errors and noise. A significant improvement of LTP performance was the addition of an optical reference channel, which allowed to partially account for systematic errors associated with wiggling and wobbling of the LTP carriage. However, the optical reference is affected by changing optical path length, non-homogeneous optics, and air turbulence. In the present work, we experimentally investigate the questions related to the use of a precision tiltmeter as a reference channel. Dependence of the tiltmeter performance on horizontal acceleration, temperature drift, motion regime, and kinematical scheme of the translation stage has been investigated. It is shown that at an appropriate experimental arrangement, the tiltmeter provides a slope reference for the LTP system with accuracy on the level of 0.1 {micro}rad (rms).

  14. What is the reference frame of an accelerated observer?

    E-Print Network [OSTI]

    K. -P. Marzlin

    1998-03-12T23:59:59.000Z

    The general construction of extended refrence frames for noninertial observers in flat space is studied. It is shown that, if the observer moves inertially before and after an arbitrary acceleration and rotation, the region where reference frames can coincide with an inertial system is bounded for final velocities exceeding 0.6 c.

  15. A Configurable Reference Modelling Language1 M. Rosemanna

    E-Print Network [OSTI]

    van der Aalst, Wil

    , Configuration, Event-driven Process Chains 1 This research project is financially supported by SAP Corporate reference models "just" depict the possible system capabilities and cannot sufficiently guide the project, Eindhoven, The Netherlands, w.m.p.v.d.aalst@tm.tue.nl Abstract Enterprise Systems (ES) are comprehensive off

  16. ILU 2.0beta1 Reference Manual Bill Janssen

    E-Print Network [OSTI]

    Janssen, Bill

    ILU 2.0beta1 Reference Manual Bill Janssen parc.xerox.com> Mike Spreitzer parc@xerox.com> Dan Larner parc@xerox.com> Chris Jacobi parc@xerox.com> (with contributions from Doug-Language Unification (ILU) system. Lots of people contributed significant amounts of code to the ILU system, including

  17. sheet is a su se refer to t

    E-Print Network [OSTI]

    Refer to your Search the on number for e f your course select will aut Make sure yo Build your tim at http://w in, build you departmenta nline course t ach course e includes a la tomatically sc ou pick nrolling stration and E website for in exchange a co ow the instruc explanation p button different lab

  18. Reference Radiation for Cosmic Rays in RBE Research

    E-Print Network [OSTI]

    Feng, Shaoyong

    2011-10-21T23:59:59.000Z

    effectiveness relative to a specific radiation is usually used. For low energy heavy ions and neutrons 250 keV photons are usually used for the reference radiation but their depth dose distribution is very different from that for cosmic rays. In this research...

  19. Flexible Reference-Counting-Based Hardware Acceleration for Garbage Collection

    E-Print Network [OSTI]

    Mutlu, Onur

    Flexible Reference-Counting-Based Hardware Acceleration for Garbage Collection José A. Joao Onur automatic memory management (garbage col- lection) are increasingly used to write all kinds of applications be- cause they provide clear software engineering and security advan- tages. Unfortunately, garbage

  20. Integrating Generations with Advanced Reference Counting Garbage Collectors

    E-Print Network [OSTI]

    Krintz, Chandra

    Integrating Generations with Advanced Reference Counting Garbage Collectors Hezi Azatchi 1 and Erez counting work on the old generation (where many objects survive). Matching the expected survival rate a couple of milliseconds. Keywords: Runtime systems, Memory management, Garbage collection, Genera- tional

  1. Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical and General Safety Program: Air Quality Owner: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 SLAC's air emissions are regulated through a federally mandated site-wide permit as well

  2. QUICK REFERENCE: Nexis service 5.1 July 2006

    E-Print Network [OSTI]

    off as many as you need. 4. Enter a search term. 5. Click on red search button. Quick ReferenceIndexing TechnologyTM in your search. 3. Search using "Terms and Connectors" or "Natural Language." Choose your preference at the top of the form. 4. Enter your keywords or phrases. 5. To refine search, click on Add

  3. Environmental engineering (buildings): a bibliography. [Over 400 references

    SciTech Connect (OSTI)

    Vance, M.

    1983-01-01T23:59:59.000Z

    The international references listed in this bibliography address energy-efficient design in the built environment in economic and human terms. Other aspects of the built environment are seating arrangements in public vehicles, urban and underground architecture, and the social impacts of new designs and technologies. (DCK)

  4. Corrosion behavior of duplex and reference cladding in NPP Grohnde

    SciTech Connect (OSTI)

    Besch, O.A. [PreussenElektra AG, Hannover (Germany); Yagnik, S.K. [Electric Power Research Inst., Palo Alto, CA (United States). Nuclear Power Group; Woods, K.N. [Siemens Power Corp., Richland, WA (United States); Eucken, C.M. [Teledyne Wah Chang, Albany, OR (United States); Bradley, E.R. [Sandvik Special Metals Corp., Kennewick, WA (United States)

    1996-12-31T23:59:59.000Z

    The Nuclear Fuel Industry Research (NFIR) Group undertook a lead test assembly (LTA) program in NPP Grohnde PWR in Germany to assess the corrosion performance of duplex and reference cladding. Two identical 16 by 16 LTAs, each containing 32 peripheral test rods, completed four reactor cycles, reaching a peak rod burnup of 46 MWd/kgU. The results from poolside examinations performed at the end of each cycle, together with power histories and coolant chemistry, are reported. Five different cladding materials were characterized during fabrication. The corrosion performance of the cladding materials was tracked in long-term tests in high-pressure, high-temperature autoclaves. The relative ranking of corrosion behavior in such tests corresponded well with the in-reactor corrosion performance. The extent and distribution of hydriding in duplex and reference specimens during the autoclave testing has been characterized. The in-reactor corrosion data indicate that the low-tin Zircaloy-4 reference cladding, R2, had an improved corrosion resistance compared to high-tin Zircaloy-4 reference cladding, R1. Two types of duplex cladding, D1 (Zr-2.5% Nb) and D2 (Zr-0.4% Fe-0.5% Sn), showed an even further improvement in corrosion resistance compared to R2 cladding. The third duplex cladding, D3 (Zr-4 + 1.0% Nb), had significantly less corrosion resistance, which was inferior to R1. The in-reactor and out-reactor corrosion performances have been ranked.

  5. BC Reference number ISO/IEC 14882:1998(E)

    E-Print Network [OSTI]

    Graham, Nick

    of International Standardization Organization (ISO), International Electrotechnical Commission (IEC), AmericanBC Reference number ISO/IEC 14882:1998(E) INTERNATIONAL STANDARD ISO/IEC 14882 First edition 1998 by ANSI as an American National Standard. Date of ANSI Approval: 7/27/98 Published by American National

  6. Unix/Linux Command Reference .com File Commands

    E-Print Network [OSTI]

    Reluga, Tim

    word in the current line Ctrl+U ­ erases the whole line Ctrl+R ­ type to bring up a recent commandUnix/Linux Command Reference .com File Commands ls ­ directory listing ls -al ­ formatted listing ­ output the contents of file head file ­ output the first 10 lines of file tail file ­ output the last 10

  7. Principles of Science Principles of Biology Reference Edition

    E-Print Network [OSTI]

    Cai, Long

    topics such as cancer, climate change and ocean health #12;How can the Principles of Biology Reference · Weekly usage reports · Advice to students seeking science careers · English communication guide to Scientific Communication · Guide to Career Planning · Insight into current science research hot topics High

  8. State of the Climate 2014: References | 1 State of the

    E-Print Network [OSTI]

    Greenslade, Diana

    .bom.gov.au/state-of-the-climate/2014 References and data GENERAL Braganza, K., Power, S., Trewin, B., Arblaster, J., Timbal, B., Hope Report No. 036. Centre for Australian Weather and Climate Research, Canberra, Australia. 106pp. Bo of Meteorology (2007). Climate change in Australia. Technical Report. www.climatechangeinaustralia.gov.au CSIRO

  9. Tax Treatment of Natural Gas The "landowner" referred to in

    E-Print Network [OSTI]

    Boyer, Elizabeth W.

    Tax Treatment of Natural Gas Marcellus Education Fact Sheet The "landowner" referred and tax op- tions available to you as a result T he Marcellus shale geological formation underlies almost in this previously un- tapped formation. The Marcellus shale natural gas boom is creating unprecedented

  10. Constraint Management in Fuel Cells: A Fast Reference Governor Approach

    E-Print Network [OSTI]

    Stefanopoulou, Anna

    admissible current demand to the fuel cell based on on-line optimization of a scalar parameter and onConstraint Management in Fuel Cells: A Fast Reference Governor Approach Ardalan Vahidi Ilya Kolmanovsky Anna Stefanopoulou Abstract-- The air supply system in a fuel cell may be susceptible

  11. Chapter 11 References Bering Sea Chinook Salmon Bycatch 629

    E-Print Network [OSTI]

    Chapter 11 References Bering Sea Chinook Salmon Bycatch 629 Final EIS ­ December 2009 11 statement for essential fish habitat identification and conservation in Alaska (EFH EIS). NMFS Alaska/61/13/8 (AFA EIS). NMFS Alaska Regional Office, PO Box 21668, Juneau, Alaska. June. URL: http://www.fakr.noaa.gov/sustainablefisheries/afa/eis

  12. Reference: RGL 81-02 Subject: NEPA-CORPS EIS

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Reference: RGL 81-02 Subject: NEPA-CORPS EIS Title: REVIEW OF ANOTHER AGENCY'S EIS Issued: 03/17/81 Expires: 12/31/83 Originator: DAEN-CWO-N Description: EIS WILL ONLY BE PREPARED WHEN CORPS PERMIT ACTION sentence of paragraph 23 of Appendix B to 33 CFR 230, a draft and final supplement to another agency's EIS

  13. January 9, 2012 In reply refer to: DKR-7

    E-Print Network [OSTI]

    for least-cost power planning. Energy efficiency is the accepted foundation of utility resource planning. By the end of 2011, the Northwest will likely have 6,000 megawatts of wind energy in operation - nine yearsJanuary 9, 2012 In reply refer to: DKR-7 Dear Chairman Measure: Department of Energy Bonneville

  14. Photoexcitation of a Volume Plasmon in Buckyballs

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Photoexcitation of a Volume Plasmon in Buckyballs Print For molecules made from a single element, buckyballs (carbon-60) are very large. They mark the transition from atoms to...

  15. Clay Mathematics Proceedings Volume 12, 2009

    E-Print Network [OSTI]

    Sart, Remi

    Clay Mathematics Proceedings Volume 12, 2009 Renormalization in connected graded Hopf cO2008 Clay Mathemat* *ics Institute 1 #12

  16. Petroleum supply annual, 1997. Volume 1

    SciTech Connect (OSTI)

    NONE

    1998-06-01T23:59:59.000Z

    The Petroleum Supply Annual (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1997 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains three sections: Summary Statistics, Detailed Statistics, and Refinery Statistics; each with final annual data. The second volume contains final statistics for each month of 1997, and replaces data previously published in the Petroleum Supply Monthly (PSM). The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. 16 figs., 48 tabs.

  17. Petroleum supply annual 1998: Volume 1

    SciTech Connect (OSTI)

    NONE

    1999-06-01T23:59:59.000Z

    The ``Petroleum Supply Annual`` (PSA) contains information on the supply and disposition of crude oil and petroleum products. The publication reflects data that were collected from the petroleum industry during 1998 through annual and monthly surveys. The PSA is divided into two volumes. This first volume contains three sections: Summary Statistics, Detailed Statistics, and Refinery Statistics; each with final annual data. The second volume contains final statistics for each month of 1998, and replaces data previously published in the PSA. The tables in Volumes 1 and 2 are similarly numbered to facilitate comparison between them. 16 figs., 59 tabs.

  18. Water Quality Program, Volume 1 (Alabama)

    Broader source: Energy.gov [DOE]

    This volume of the water quality program mainly deals with the National Pollutant Discharge Elimination System. National Pollutant Discharge Elimination System" or "(NPDES)" means the national...

  19. Volume, Number of Shipments Surpass Goals

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Laboratory," said Pete Maggiore, assistant manager for environmental operations at the NNSA Los Alamos Site Office. "We exceeded our goals and are on track to double both volume...

  20. Water Quality Program, Volume 2 (Alabama)

    Broader source: Energy.gov [DOE]

    This volume of the water quality program mainly deals with Technical Standards, Corrective Action Requirements and Financial Responsibility for Owners and Operators of Underground Storage Tanks....

  1. ARE Update Volume 13, Number 4

    E-Print Network [OSTI]

    2010-01-01T23:59:59.000Z

    Use of U.S. Croplands for Biofuels In- creases Greenhousea mini- mum volume of biofuels and requires a nationalper unit of various biofuels. For example, corn ethanol

  2. Volume 7, No.4Volume 7, No.4 2012 Year in Review

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Volume 7, No.4Volume 7, No.4 2012 Year in Review Special Focus: Taking Care of our Wounded Warriors Focus: Year in Review onthecover The Southwestern Division takes a look back at the year 2012 through

  3. Scuttlebutt Volume 1, No. 7

    E-Print Network [OSTI]

    2007-01-01T23:59:59.000Z

    #1;#2;#3;#4;#4;#5;#6;#7;#3;#4;#4; We assembled in Adelaide in South Australia and as a group of friends we gathered together to celebrate the culmination of more than nine months hard work, to receive the commissioning of our chapter and ship...-copy print? You can get references & in-depth info by following the blue underlined hyplinks in the pdf copy of this newsletter that is available for free download from http://www.uss-southerncross.com/news.htm #1;#2;#2;#3;#4;#5;#5;#6;#6;#6;#7;#8; #11...

  4. application reference efsa-gmo-nl-2005-15: Topics by E-print...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    20 21 22 23 24 25 Next Page Last Page Topic Index 1 Application Protocol Reference Architecture Application Protocol Reference Architecture Computer Technologies and Information...

  5. application reference efsa-gmo-uk-2005-21: Topics by E-print...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    20 21 22 23 24 25 Next Page Last Page Topic Index 1 Application Protocol Reference Architecture Application Protocol Reference Architecture Computer Technologies and Information...

  6. application reference efsa-gmo-rx-bt11: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    20 21 22 23 24 25 Next Page Last Page Topic Index 1 Application Protocol Reference Architecture Application Protocol Reference Architecture Computer Technologies and Information...

  7. 264 VOLUME 13J O U R N A L O F C L I M A T E 2000 American Meteorological Society

    E-Print Network [OSTI]

    on the relationship between the earth radiation budget or sur- face radiation budget and total cloud cover (see refer shortwave and longwave radiative flux- es as much as changes in total cloud cover and because264 VOLUME 13J O U R N A L O F C L I M A T E 2000 American Meteorological Society Radiative Effects

  8. A coarse entropy-rigidity theorem and discrete length-volume inequalities

    E-Print Network [OSTI]

    Kinneberg, Kyle Edward

    2014-01-01T23:59:59.000Z

    A discrete length-volume inequality . . . . . . . .v 3 Length-volume inequalities revisitedlength-volume inequality for cubes . . . . . . . . . . . .

  9. Direct Rendering of Deformable Volume Data Shiaofen Fang

    E-Print Network [OSTI]

    Fang, Shiaofen

    Direct Rendering of Deformable Volume Data Shiaofen Fang Department of Computer and Information In this paper, we present a new deformable volume rendering algorithm. The volume deformation is modeled to directly render the deformed volume without going through the expensive volume construction process

  10. Recommendations for a Department of Energy Nuclear Energy R and D Agenda Volume 2 Appendices

    SciTech Connect (OSTI)

    NONE

    1997-12-01T23:59:59.000Z

    The current US nuclear energy policy is primarily formulated as part of the nation`s overall energy policy. In addition, nuclear energy policy is impacted by other US policies, such as those for defense and environment, and by international obligations through their effects on nuclear weapons dismantlement and stewardship, continued reliance on space and naval nuclear power sources, defense waste cleanup, and on nuclear nonproliferation. This volume is composed of the following appendices: Appendix 1--Objectives of the Federal Government Nuclear Energy Related Policies and Research and Development Programs; Appendix 2--Nuclear Energy and Related R and D in the US; Appendix 3--Summary of Issues That Drive Nuclear Energy Research and Development; Appendix 4: Options for Policy and Research and Development; Appendix 5--Pros and Cons of Objectives and Options; and Appendices 6--Recommendations.

  11. Information architecture. Volume 3: Guidance

    SciTech Connect (OSTI)

    NONE

    1997-04-01T23:59:59.000Z

    The purpose of this document, as presented in Volume 1, The Foundations, is to assist the Department of Energy (DOE) in developing and promulgating information architecture guidance. This guidance is aimed at increasing the development of information architecture as a Departmentwide management best practice. This document describes departmental information architecture principles and minimum design characteristics for systems and infrastructures within the DOE Information Architecture Conceptual Model, and establishes a Departmentwide standards-based architecture program. The publication of this document fulfills the commitment to address guiding principles, promote standard architectural practices, and provide technical guidance. This document guides the transition from the baseline or defacto Departmental architecture through approved information management program plans and budgets to the future vision architecture. This document also represents another major step toward establishing a well-organized, logical foundation for the DOE information architecture.

  12. Ironmaking conference proceedings. Volume 54

    SciTech Connect (OSTI)

    NONE

    1995-12-01T23:59:59.000Z

    The technical presentations at this conference displayed a renewed sense of viability of the coke and ironmaking community. In addition, many of the papers show that the environmental aspects of ironmaking are being integrated into day-to-day operations rather than being thought of as separate responsibilities. This volume contains 68 papers divided into the following sections: Blast furnace injection; Blast furnace fundamental studies; Blast furnace general; Blast furnace repairs/rebuilds/modernization; Process control techniques for blast furnaces; Cokemaking general; Cokemaking environmental; Coke--by-products--plant operations; Coal and coke research; Battery operations; Pelletizing; Direct reduction and smelting; and Sintering. Most of the papers have been processed separately for inclusion on the data base.

  13. November 2013 Volume 8, Issue 8

    E-Print Network [OSTI]

    Oklahoma, University of

    several thousand fungi from soil samples primarily obtained from three environmentally disparate regions Transportation Systems Lab lent mo- bile equipment and technical support to assist in traffic management. With this approach, OU researchers team with the public to sample soils from across the United States for the purpose

  14. Dimensional SPC for low-volume production

    E-Print Network [OSTI]

    Chin, Chang-Ho

    1999-01-01T23:59:59.000Z

    . To make up for the weaknesses of SPC in low-volume production, a new method to test data independence, a new plot to describe the similarity between two charts, and two modified graphical tools are proposed. In low-volume production, it is frequently hard...

  15. antioxidants acting primarily: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to make such amendments of the law relating to public health and the functions of county councils and other local authorities as are commonly made in local... Her Majesty's...

  16. Research Profile Our lab is primarily interested in

    E-Print Network [OSTI]

    Sandoghdar, Vahid

    func- tionalities ­ 3D Printing and rapid prototyping of novel materials ­ Micro- and Nano and shocks as they propagate through the crystals. We research energy trapping, stress redirection. For our design, we take inspiration from hard biological systems and study experi- mentally the energy

  17. Reference value developed for mechanical integrity of storage caverns

    SciTech Connect (OSTI)

    Crotogino, F. [Kavernen Bau- and Betriebs-GmbH, Hannover (Germany)

    1996-10-28T23:59:59.000Z

    A reference value to verify the mechanical integrity of salt-cavern wells used in hydrocarbon storage has been developed. Salt caverns play important roles in large-scale storage of hydrocarbon gases and liquids. Required for safe and economical operation of these storage caverns is verification of the external mechanical integrity of the access (injection and withdrawal) wells. This study had the following goals: Provision of an overview of current practice; and Development of a reference for external well mechanical-integrity testing with respect to performance, data evaluation, and assessment. The storage cavern operators expected to gain the following: Comparability between method and assessments; Aid in influencing the movement towards standardization by regulators; and A firm technical base for use in litigation between the operator and other parties.

  18. Reference-area performance standards for Puget Sound

    SciTech Connect (OSTI)

    Not Available

    1991-09-01T23:59:59.000Z

    Chemical and biological conditions in the sediments at sites in three areas of Puget Sound were analyzed as part of the study. Analysis of sediments from Samish Bay, Holmes Harbor, and Carr Inlet included chemical concentrations, total organic carbon, acid-volatile sulfides, total solids, grain size distribution, and sediment toxicity as measured by amphipod mortality, bivalve larvae mortality and abnormality, echinoderm embryo mortality and abnormality, juvenile polychaete mortality and biomass, and saline Microtox bacterial luminescence bioassays. The performance standards developed for Puget Sound sediment reference sites will provide a consistent basis for comparison and use of sediment data collected by various programs. Based on the performance standards developed, the report found specific stations in Carr Inlet, Holmes Harbor, and Samish Bay to be suitable as sediment reference areas.

  19. A reference worldwide model for antineutrinos from reactors

    E-Print Network [OSTI]

    Baldoncini, Marica; Fiorentini, Giovanni; Mantovani, Fabio; Ricci, Barbara; Strati, Virginia; Xhixha, Gerti

    2014-01-01T23:59:59.000Z

    Antineutrinos produced at nuclear reactors constitute a severe source of background for the detection of geoneutrinos, which bring to the Earth's surface information about natural radioactivity in the whole planet. In this framework we provide a reference worldwide model for antineutrinos from reactors, in view of reactors operational records yearly published by the International Atomic Energy Agency (IAEA). We evaluate the expected signal from commercial reactors for ongoing (KamLAND and Borexino), planned (SNO+) and proposed (Juno, RENO-50, LENA and Hanohano) experimental sites. Uncertainties related to reactor antineutrino production, propagation and detection processes are estimated using a Monte Carlo based approach, which provides an overall site dependent uncertainty on the signal in the geoneutrino energy window on the order of 3%. We also implement the off-equilibrium correction to the reference reactor spectra associated with the long-lived isotopes and we estimate a 2.4% increase of the unoscillate...

  20. Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

    SciTech Connect (OSTI)

    Yu, Y. H.; Jenne, D. S.; Thresher, R.; Copping, A.; Geerlofs, S.; Hanna, L. A.

    2015-01-01T23:59:59.000Z

    This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter (OSWEC) reference model design in a complementary manner to Reference Models 1-4 contained in the above report. A conceptual design for a taut moored oscillating surge wave energy converter was developed. The design had an annual electrical power of 108 kilowatts (kW), rated power of 360 kW, and intended deployment at water depths between 50 m and 100 m. The study includes structural analysis, power output estimation, a hydraulic power conversion chain system, and mooring designs. The results were used to estimate device capital cost and annual operation and maintenance costs. The device performance and costs were used for the economic analysis, following the methodology presented in SAND2013-9040 that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays up to 100 devices. The levelized cost of energy estimated for the Reference Model 5 OSWEC, presented in this report, was for a single device and arrays of 10, 50, and 100 units, and it enabled the economic analysis to account for cost reductions associated with economies of scale. The baseline commercial levelized cost of energy estimate for the Reference Model 5 device in an array comprised of 10 units is $1.44/kilowatt-hour (kWh), and the value drops to approximately $0.69/kWh for an array of 100 units.